{"lab":{"_id":"69ad52a3de79e566650fb628","accr_number":"AB 1197","country":"PL","accr_body":"PCA","address":"ZESPÓŁ LABORATORYJNY, ul. Iwona Odrowąża 7, 30-901 Kraków","categories":["environment","water","microbiology"],"city":"Kraków","imported_at":"2026-03-08T10:42:43.265Z","methods_count":54,"name":"WOJSKOWY OŚRODEK MEDYCYNY PREWENCYJNEJ - KRAKÓW","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1197.pdf"],"scope_summary":"","search_text":"wojskowy ośrodek medycyny prewencyjnej - kraków zespół laboratoryjny, ul. iwona odrowąża 7, 30-901 kraków microbiology other environment pharma electronics metrology materials automotive water food","status":"active","updated_at":"2026-03-08T14:50:22.892Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T08:54:36.731Z","email_confidence":"high","email_mx":true,"email_source":"https://womp-krakow.wp.mil.pl/kontakt-2017-01-16-4/","parse_date":"2026-08-17T08:54:36.731Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"C/28, C/29","pl":"Badania chemiczne wody, wody do spożycia przez ludzi","en":"Chemical tests of water, drinking water"},{"codes":"C/33/P","pl":"Badania chemiczne i pobieranie próbek powietrza","en":"Chemical tests and sampling of air"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) środowisko pracy (czynniki szkodliwe i uciążliwe-hałas, oświetlenie, pole elektromagnetyczne)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful and nuisance factors – lighting, noise, electromagnetic"},{"codes":"K/3, K/28, K/29","pl":"Badania mikrobiologiczne obiektów i materiałów biologicznych przeznaczonych do badań, wody, wody do spożycia przez ludzi","en":"Microbiological tests of of biological items and materials for testing,water, drinking water"},{"codes":"N/28, N/29","pl":"Badania właściwości fizycznych wody, wody do spożycia przez ludzi","en":"Tests of physical properties of water, drinking water"},{"codes":"N/33/P","pl":"Badanie właściwości fizycznych i pobieranie próbek powietrza","en":"Tests of physical properties and sampling of air"}],"issue":{"no":"19","date":"08.07.2026"},"map_coord":[50.07933,19.933772],"map_geo":"nominatim-street","lab_locations":[{"name":"ZESPÓŁ LABORATORYJNY","address":"ul. Iwona Odrowąża 7","city":null,"postal":null},{"name":"Laboratorium Mikrobiologiczne","address":"ul. Iwona Odrowąża 7,30-901 Kraków","city":"Kraków","postal":"30-901"},{"name":"Laboratorium Badań Środowiska Pracy","address":"ul. Iwona Odrowąża 7,30-901 Kraków","city":"Kraków","postal":"30-901"},{"name":"Laboratorium Badań Żywności i Wody","address":"ul. Iwona Odrowąża 7,30-901 Kraków","city":"Kraków","postal":"30-901"}],"scope_format":"PCA::pracownie+siatka5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/62e18aaa78e004b2c0b8173da5fac163/AB%201197.pdf","has_en":true,"category_counts":{"environment":29,"water":19,"microbiology":6,"other":4,"automotive":3,"materials":1},"category_scores":{"environment":13.56,"water":5.82,"microbiology":0.58,"other":0.26,"automotive":0.15,"materials":0.02},"has_zh":true,"lab_locations_zh":[{"name":"ZESPÓŁ LABORATORYJNY","address":"ul. Iwona Odrowąża 7","city":null,"postal":null},{"name":"微生物实验室","address":"ul. Iwona Odrowąża 7,30-901 Kraków","city":"Kraków","postal":"30-901"},{"name":"工作场所环境检测实验室","address":"ul. Iwona Odrowąża 7,30-901 Kraków","city":"Kraków","postal":"30-901"},{"name":"Laboratorium Badań Żywności i Wody","address":"ul. Iwona Odrowąża 7,30-901 Kraków","city":"Kraków","postal":"30-901"}]},"methods":[{"_id":"6a82cc4c884ede9a1b2c2dca","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Kał","methodology":"Obecność pasożytów jelitowych","parameters":[],"technique":"Metoda mikroskopowa","techniques":["Metoda mikroskopowa"],"computed":[],"activity":"Obecność pasożytów jelitowych\nMetoda mikroskopowa","reference":"PB-LM-02 wyd. 2 z dnia 04.01.2012 r. w oparciu o „Standardy w zakresie laboratoryjnych czynności w parazytologii medycznej, oceny ich jakości i wartości diagnostycznej oraz laboratoryjnej interpretacji i autoryzacji wyników badań (propozycje)” Journal of Laboratory Diagnostics 2011; 47: 341-351","norm_bases":["PB-LM-02 wyd. 2 z dnia 04.01.2012 r. w oparciu o „Standardy w zakresie laboratoryjnych czynności w parazytologii medycznej, oceny ich jakości i wartości diagnostycznej oraz laboratoryjnej interpretacji i autoryzacji wyników badań (propozycje)” Journal of Laboratory Diagnostics 2011; 47: 341-351"],"lab_section":"Laboratorium Mikrobiologiczne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał Obecność pasożytów jelitowych\nMetoda mikroskopowa PB-LM-02 wyd. 2 z dnia 04.01.2012 r. w oparciu o „Standardy w zakresie laboratoryjnych czynności w parazytologii medycznej, oceny ich jakości i wartości diagnostycznej oraz laboratoryjnej interpretacji i autoryzacji wyników badań (propozycje)” Journal of Laboratory Diagnostics 2011; 47: 341-351 Kal Obecnosc pasozytow jelitowych\nMetoda mikroskopowa PB-LM-02 wyd. 2 z dnia 04.01.2012 r. w oparciu o „Standardy w zakresie laboratoryjnych czynnosci w parazytologii medycznej, oceny ich jakosci i wartosci diagnostycznej oraz laboratoryjnej interpretacji i autoryzacji wynikow badan (propozycje)” Journal of Laboratory Diagnostics 2011; 47: 341-351","categories":["other"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory","methodology_en":"Presence of intestinal parasites","search_en":"Faeces Presence of intestinal parasites Microscopic method Microbiology Laboratory PB-LM-02 wyd. 2 z dnia 04.01.2012 r. w oparciu o „Standardy w zakresie laboratoryjnych czynności w parazytologii medycznej, oceny ich jakości i wartości diagnostycznej oraz laboratoryjnej interpretacji i autoryzacji wyników badań (propozycje)” Journal of Laboratory Diagnostics 2011; 47: 341-351","technique_en":"Microscopic method","test_object_en":"Faeces","search_zh":"粪便 显微镜法 微生物实验室 PB-LM-02 wyd. 2 z dnia 04.01.2012 r. w oparciu o „Standardy w zakresie laboratoryjnych czynności w parazytologii medycznej, oceny ich jakości i wartości diagnostycznej oraz laboratoryjnej interpretacji i autoryzacji wyników badań (propozycje)” Journal of Laboratory Diagnostics 2011; 47: 341-351","test_object_zh":"粪便","technique_zh":"显微镜法","lab_section_zh":"微生物实验室"},{"_id":"6a82cc4c884ede9a1b2c2dcb","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Kał, wymaz z odbytu","methodology":"Obecność pałeczek jelitowych z rodzaju Salmonella i Shigella","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność pałeczek jelitowych z rodzaju Salmonella i Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB-LM-01 wyd. 3 z dnia 01.03.2016 r. w oparciu o Rekomendacje Narodowego Instytutu Zdrowia Publicznego Państwowego Zakładu Higieny i Krajowej Izby Diagnostów Laboratoryjnych","norm_bases":["PB-LM-01 wyd. 3 z dnia 01.03.2016 r. w oparciu o Rekomendacje Narodowego Instytutu Zdrowia Publicznego Państwowego Zakładu Higieny i Krajowej Izby Diagnostów Laboratoryjnych"],"lab_section":"Laboratorium Mikrobiologiczne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał, wymaz z odbytu Obecność pałeczek jelitowych z rodzaju Salmonella i Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-LM-01 wyd. 3 z dnia 01.03.2016 r. w oparciu o Rekomendacje Narodowego Instytutu Zdrowia Publicznego Państwowego Zakładu Higieny i Krajowej Izby Diagnostów Laboratoryjnych Kal, wymaz z odbytu Obecnosc paleczek jelitowych z rodzaju Salmonella i Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-LM-01 wyd. 3 z dnia 01.03.2016 r. w oparciu o Rekomendacje Narodowego Instytutu Zdrowia Publicznego Panstwowego Zakladu Higieny i Krajowej Izby Diagnostow Laboratoryjnych","categories":["microbiology"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory","search_en":"Faeces, rectal swab Culture method with biochemical and serological confirmation Microbiology Laboratory PB-LM-01 wyd. 3 z dnia 01.03.2016 r. w oparciu o Rekomendacje Narodowego Instytutu Zdrowia Publicznego Państwowego Zakładu Higieny i Krajowej Izby Diagnostów Laboratoryjnych","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Faeces, rectal swab","search_zh":"粪便、肛拭子 培养法结合生化与血清学确认 微生物实验室 PB-LM-01 wyd. 3 z dnia 01.03.2016 r. w oparciu o Rekomendacje Narodowego Instytutu Zdrowia Publicznego Państwowego Zakładu Higieny i Krajowej Izby Diagnostów Laboratoryjnych","technique_zh":"培养法结合生化与血清学确认","test_object_zh":"粪便、肛拭子","lab_section_zh":"微生物实验室"},{"_id":"6a82cc4c884ede9a1b2c2dcc","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Kał, wymaz z odbytu","methodology":"Obecność pałeczek jelitowych z rodzaju Yersinia","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność pałeczek jelitowych z rodzaju Yersinia\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PB-LM-07 wyd. 3 z dnia 10.01.2019 w oparciu o Rekomendacje Narodowego Instytutu Zdrowia Publicznego Państwowego Zakładu Higieny i Krajowej Izby Diagnostów Laboratoryjnych","norm_bases":["PB-LM-07 wyd. 3 z dnia 10.01.2019 w oparciu o Rekomendacje Narodowego Instytutu Zdrowia Publicznego Państwowego Zakładu Higieny i Krajowej Izby Diagnostów Laboratoryjnych"],"lab_section":"Laboratorium Mikrobiologiczne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał, wymaz z odbytu Obecność pałeczek jelitowych z rodzaju Yersinia\nMetoda hodowlana z potwierdzeniem biochemicznym PB-LM-07 wyd. 3 z dnia 10.01.2019 w oparciu o Rekomendacje Narodowego Instytutu Zdrowia Publicznego Państwowego Zakładu Higieny i Krajowej Izby Diagnostów Laboratoryjnych Kal, wymaz z odbytu Obecnosc paleczek jelitowych z rodzaju Yersinia\nMetoda hodowlana z potwierdzeniem biochemicznym PB-LM-07 wyd. 3 z dnia 10.01.2019 w oparciu o Rekomendacje Narodowego Instytutu Zdrowia Publicznego Panstwowego Zakladu Higieny i Krajowej Izby Diagnostow Laboratoryjnych","categories":["other"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory","search_en":"Faeces, rectal swab Culture method with biochemical confirmation Microbiology Laboratory PB-LM-07 wyd. 3 z dnia 10.01.2019 w oparciu o Rekomendacje Narodowego Instytutu Zdrowia Publicznego Państwowego Zakładu Higieny i Krajowej Izby Diagnostów Laboratoryjnych","technique_en":"Culture method with biochemical confirmation","test_object_en":"Faeces, rectal swab","search_zh":"粪便、肛拭子 培养法结合生化确认 微生物实验室 PB-LM-07 wyd. 3 z dnia 10.01.2019 w oparciu o Rekomendacje Narodowego Instytutu Zdrowia Publicznego Państwowego Zakładu Higieny i Krajowej Izby Diagnostów Laboratoryjnych","technique_zh":"培养法结合生化确认","test_object_zh":"粪便、肛拭子","lab_section_zh":"微生物实验室"},{"_id":"6a82cc4c884ede9a1b2c2dcd","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Kał, wymaz z odbytu","methodology":"Obecność pałeczek jelitowych z rodzaju Campylobacter","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność pałeczek jelitowych z rodzaju Campylobacter\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PB-LM-09 wyd. 3 z dnia 10.01.2019 w oparciu o Rekomendacje Narodowego Instytutu Zdrowia Publicznego Państwowego Zakładu Higieny i Krajowej Izby Diagnostów Laboratoryjnych","norm_bases":["PB-LM-09 wyd. 3 z dnia 10.01.2019 w oparciu o Rekomendacje Narodowego Instytutu Zdrowia Publicznego Państwowego Zakładu Higieny i Krajowej Izby Diagnostów Laboratoryjnych"],"lab_section":"Laboratorium Mikrobiologiczne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał, wymaz z odbytu Obecność pałeczek jelitowych z rodzaju Campylobacter\nMetoda hodowlana z potwierdzeniem biochemicznym PB-LM-09 wyd. 3 z dnia 10.01.2019 w oparciu o Rekomendacje Narodowego Instytutu Zdrowia Publicznego Państwowego Zakładu Higieny i Krajowej Izby Diagnostów Laboratoryjnych Kal, wymaz z odbytu Obecnosc paleczek jelitowych z rodzaju Campylobacter\nMetoda hodowlana z potwierdzeniem biochemicznym PB-LM-09 wyd. 3 z dnia 10.01.2019 w oparciu o Rekomendacje Narodowego Instytutu Zdrowia Publicznego Panstwowego Zakladu Higieny i Krajowej Izby Diagnostow Laboratoryjnych","categories":["other"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory","search_en":"Faeces, rectal swab Culture method with biochemical confirmation Microbiology Laboratory PB-LM-09 wyd. 3 z dnia 10.01.2019 w oparciu o Rekomendacje Narodowego Instytutu Zdrowia Publicznego Państwowego Zakładu Higieny i Krajowej Izby Diagnostów Laboratoryjnych","technique_en":"Culture method with biochemical confirmation","test_object_en":"Faeces, rectal swab","search_zh":"粪便、肛拭子 培养法结合生化确认 微生物实验室 PB-LM-09 wyd. 3 z dnia 10.01.2019 w oparciu o Rekomendacje Narodowego Instytutu Zdrowia Publicznego Państwowego Zakładu Higieny i Krajowej Izby Diagnostów Laboratoryjnych","technique_zh":"培养法结合生化确认","test_object_zh":"粪便、肛拭子","lab_section_zh":"微生物实验室"},{"_id":"6a82cc4c884ede9a1b2c2dce","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Kał, wymaz z odbytu","methodology":"Obecność pałeczek jelitowych Plesiomonas shigelloides i z rodzaju Aeromonas.","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność pałeczek jelitowych Plesiomonas shigelloides i z rodzaju Aeromonas.\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PB-LM-18 wyd. 2 z dnia 10.01.2019 w oparciu o Rekomendacje Narodowego Instytutu Zdrowia Publicznego Państwowego Zakładu Higieny i Krajowej Izby Diagnostów Laboratoryjnych","norm_bases":["PB-LM-18 wyd. 2 z dnia 10.01.2019 w oparciu o Rekomendacje Narodowego Instytutu Zdrowia Publicznego Państwowego Zakładu Higieny i Krajowej Izby Diagnostów Laboratoryjnych"],"lab_section":"Laboratorium Mikrobiologiczne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał, wymaz z odbytu Obecność pałeczek jelitowych Plesiomonas shigelloides i z rodzaju Aeromonas.\nMetoda hodowlana z potwierdzeniem biochemicznym PB-LM-18 wyd. 2 z dnia 10.01.2019 w oparciu o Rekomendacje Narodowego Instytutu Zdrowia Publicznego Państwowego Zakładu Higieny i Krajowej Izby Diagnostów Laboratoryjnych Kal, wymaz z odbytu Obecnosc paleczek jelitowych Plesiomonas shigelloides i z rodzaju Aeromonas.\nMetoda hodowlana z potwierdzeniem biochemicznym PB-LM-18 wyd. 2 z dnia 10.01.2019 w oparciu o Rekomendacje Narodowego Instytutu Zdrowia Publicznego Panstwowego Zakladu Higieny i Krajowej Izby Diagnostow Laboratoryjnych","categories":["other"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory","search_en":"Faeces, rectal swab Culture method with biochemical confirmation Microbiology Laboratory PB-LM-18 wyd. 2 z dnia 10.01.2019 w oparciu o Rekomendacje Narodowego Instytutu Zdrowia Publicznego Państwowego Zakładu Higieny i Krajowej Izby Diagnostów Laboratoryjnych","technique_en":"Culture method with biochemical confirmation","test_object_en":"Faeces, rectal swab","search_zh":"粪便、肛拭子 培养法结合生化确认 微生物实验室 PB-LM-18 wyd. 2 z dnia 10.01.2019 w oparciu o Rekomendacje Narodowego Instytutu Zdrowia Publicznego Państwowego Zakładu Higieny i Krajowej Izby Diagnostów Laboratoryjnych","technique_zh":"培养法结合生化确认","test_object_zh":"粪便、肛拭子","lab_section_zh":"微生物实验室"},{"_id":"6a82cc4c884ede9a1b2c2dcf","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Biologiczne wskaźniki kontroli skuteczności sterylizacji","methodology":"Obecność drobnoustrojów wskaźnikowych Geobacillus stearothermophilus, Bacillus subtilis","parameters":[],"technique":"Metoda hodowlana","techniques":["Metoda hodowlana"],"computed":[],"activity":"Obecność drobnoustrojów wskaźnikowych Geobacillus stearothermophilus, Bacillus subtilis\nMetoda hodowlana","reference":"PB-LM-03 wyd. 5. z dnia 23.01.2023 w oparciu o instrukcję producenta testów","norm_bases":["PB-LM-03 wyd. 5. z dnia 23.01.2023 w oparciu o instrukcję producenta testów"],"lab_section":"Laboratorium Mikrobiologiczne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Biologiczne wskaźniki kontroli skuteczności sterylizacji Obecność drobnoustrojów wskaźnikowych Geobacillus stearothermophilus, Bacillus subtilis\nMetoda hodowlana PB-LM-03 wyd. 5. z dnia 23.01.2023 w oparciu o instrukcję producenta testów Biologiczne wskazniki kontroli skutecznosci sterylizacji Obecnosc drobnoustrojow wskaznikowych Geobacillus stearothermophilus, Bacillus subtilis\nMetoda hodowlana PB-LM-03 wyd. 5. z dnia 23.01.2023 w oparciu o instrukcje producenta testow","categories":["microbiology"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory","methodology_en":"Presence of indicator microorganisms Geobacillus stearothermophilus, Bacillus subtilis","search_en":"Biological indicators for the control of sterilization efficacy Presence of indicator microorganisms Geobacillus stearothermophilus, Bacillus subtilis Culture method Microbiology Laboratory PB-LM-03 wyd. 5. z dnia 23.01.2023 w oparciu o instrukcję producenta testów","technique_en":"Culture method","test_object_en":"Biological indicators for the control of sterilization efficacy","search_zh":"灭菌效果监测用生物指示物 培养法 微生物实验室 PB-LM-03 wyd. 5. z dnia 23.01.2023 w oparciu o instrukcję producenta testów","technique_zh":"培养法","test_object_zh":"灭菌效果监测用生物指示物","lab_section_zh":"微生物实验室"},{"_id":"6a82cc4c884ede9a1b2c2dd0","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Maksymalny poziom dźwięku A,"},{"name":"Zakres","range":"(55 – 136) dB"},{"name":"Szczytowy poziom dźwięku C,"},{"name":"Zakres","range":"(55 – 136) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres:\nMaksymalny poziom dźwięku A,\nZakres (55 – 136) dB\nSzczytowy poziom dźwięku C,\nZakres (55 – 136) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 strategię 3 - punkt 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 strategię 3 - punkt 11"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A\nZakres:\nMaksymalny poziom dźwięku A,\nZakres (55 – 136) dB\nSzczytowy poziom dźwięku C,\nZakres (55 – 136) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 strategię 3 - punkt 11 Srodowisko pracy - halas Rownowazny poziom dzwieku A\nZakres:\nMaksymalny poziom dzwieku A,\nZakres (55 – 136) dB\nSzczytowy poziom dzwieku C,\nZakres (55 – 136) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 - punkt 10 strategie 3 - punkt 11","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Maksymalny poziom dźwięku A,"},{"name":"Range","range":"(55 – 136) dB"},{"name":"C-weighted peak sound pressure level,"},{"name":"Range","range":"(55 – 136) dB"}],"search_en":"Workplace environment - noise A-weighted equivalent sound pressure level Direct measurement method Workplace Environment Testing Laboratory Range C-weighted peak sound pressure level, Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 strategię 3 - punkt 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - noise","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"Maksymalny poziom dźwięku A,"},{"name":"范围","range":"(55 – 136) dB"},{"name":"C 计权峰值声级，"},{"name":"范围","range":"(55 – 136) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 直接测量法 工作场所环境检测实验室 范围 C 计权峰值声级， 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 strategię 3 - punkt 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"工作场所环境检测实验室"},{"_id":"6a82cc4c884ede9a1b2c2dd1","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Poziom ekspozycji na hałas w odniesieniu do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas w odniesieniu do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 strategię 3 - punkt 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 strategię 3 - punkt 11"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas w odniesieniu do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 strategię 3 - punkt 11 Srodowisko pracy - halas Poziom ekspozycji na halas w odniesieniu do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 - punkt 10 strategie 3 - punkt 11","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment - noise Workplace Environment Testing Laboratory an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 strategię 3 - punkt 11","test_object_en":"Workplace environment - noise","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 工作场所环境检测实验室 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 strategię 3 - punkt 11","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"工作场所环境检测实验室"},{"_id":"6a82cc4c884ede9a1b2c2dd2","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(10-5000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (10-5000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (10-5000) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (10-5000) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(10-5000) lx"}],"search_en":"Workplace environment - indoor electric lighting Illuminance Direct measurement method Workplace Environment Testing Laboratory Range PN-83/E-04040.03","technique_en":"Direct measurement method","test_object_en":"Workplace environment - indoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(10-5000) lx"}],"search_zh":"工作场所环境 — 室内电气照明 照度 直接测量法 工作场所环境检测实验室 范围 PN-83/E-04040.03","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 室内电气照明","lab_section_zh":"工作场所环境检测实验室"},{"_id":"6a82cc4c884ede9a1b2c2dd3","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment - indoor electric lighting Illuminance uniformity (calculated) Workplace Environment Testing Laboratory PN-83/E-04040.03","test_object_en":"Workplace environment - indoor electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 — 室内电气照明 照度均匀度（计算值） 工作场所环境检测实验室 PN-83/E-04040.03","test_object_zh":"工作场所环境 — 室内电气照明","lab_section_zh":"工作场所环境检测实验室"},{"_id":"6a82cc4c884ede9a1b2c2dd4","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie benzenu","parameters":[{"name":"Zakres","range":"(0,16-40) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)"],"computed":[],"activity":"Stężenie benzenu\nZakres (0,16-40) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","reference":"PN-Z-04016-10:2005","norm_bases":["PN-Z-04016-10:2005"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie benzenu\nZakres (0,16-40) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID) PN-Z-04016-10:2005 Srodowisko pracy - powietrze Stezenie benzenu\nZakres (0,16-40) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC – FID) PN-Z-04016-10:2005","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Benzene concentration","parameters_en":[{"name":"Range","range":"(0,16-40) mg/m3"}],"search_en":"Workplace environment - air Benzene concentration Gas chromatography with flame ionization detection (GC – FID) Workplace Environment Testing Laboratory Range PN-Z-04016-10:2005","technique_en":"Gas chromatography with flame ionization detection (GC – FID)","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"范围","range":"(0,16-40) mg/m3"}],"search_zh":"工作场所环境 — 空气 苯浓度 工作场所环境检测实验室 范围 PN-Z-04016-10:2005","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"工作场所环境检测实验室","methodology_zh":"苯浓度"},{"_id":"6a82cc4c884ede9a1b2c2dd5","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie toluenu","parameters":[{"name":"Zakres","range":"(10-200) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC– FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC– FID)"],"computed":[],"activity":"Stężenie toluenu\nZakres (10-200) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC– FID)","reference":"PN-Z-04115-01:1978","norm_bases":["PN-Z-04115-01:1978"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie toluenu\nZakres (10-200) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC– FID) PN-Z-04115-01:1978 Srodowisko pracy - powietrze Stezenie toluenu\nZakres (10-200) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC– FID) PN-Z-04115-01:1978","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Toluene concentration","parameters_en":[{"name":"Range","range":"(10-200) mg/m3"}],"search_en":"Workplace environment - air Toluene concentration Workplace Environment Testing Laboratory Range PN-Z-04115-01:1978","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"范围","range":"(10-200) mg/m3"}],"search_zh":"工作场所环境 — 空气 甲苯浓度 工作场所环境检测实验室 范围 PN-Z-04115-01:1978","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"工作场所环境检测实验室","methodology_zh":"甲苯浓度"},{"_id":"6a82cc4c884ede9a1b2c2dd6","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Pobieranie próbek w celu oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"substancje nieorganiczne, w tym"},{"name":"frakcja respirabilna"},{"name":"substancje organiczne, w tym"},{"name":"frakcja wdychalna"},{"name":"metale i ich związki, w tym"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek w celu oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje nieorganiczne, w tym\nfrakcja respirabilna\nsubstancje organiczne, w tym\nfrakcja wdychalna\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002/AZ1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002/AZ1:2004"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Pobieranie próbek w celu oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje nieorganiczne, w tym\nfrakcja respirabilna\nsubstancje organiczne, w tym\nfrakcja wdychalna\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002/AZ1:2004 Srodowisko pracy - powietrze Pobieranie probek w celu oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje nieorganiczne, w tym\nfrakcja respirabilna\nsubstancje organiczne, w tym\nfrakcja wdychalna\nmetale i ich zwiazki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002/AZ1:2004","categories":["materials","environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"inorganic substances, including"},{"name":"respirable fraction"},{"name":"organic substances, including"},{"name":"inhalable fraction"},{"name":"metals and their compounds, including"},{"name":"inhalable fraction"},{"name":"respirable fraction"}],"search_en":"Workplace environment - air Sampling for the assessment of occupational exposure to: Personal dosimetry method Workplace Environment Testing Laboratory dust agents inhalable fraction respirable fraction inorganic substances, including respirable fraction organic substances, including inhalable fraction metals and their compounds, including inhalable fraction respirable fraction PN-Z-04008-7:2002 | PN-Z-04008-7:2002/AZ1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"粉尘因素"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"无机物质，包括"},{"name":"呼吸性组分"},{"name":"有机物质，包括"},{"name":"可吸入组分"},{"name":"金属及其化合物，包括"},{"name":"可吸入组分"},{"name":"呼吸性组分"}],"search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 工作场所环境检测实验室 粉尘因素 可吸入组分 呼吸性组分 无机物质，包括 呼吸性组分 有机物质，包括 可吸入组分 金属及其化合物，包括 可吸入组分 呼吸性组分 PN-Z-04008-7:2002 | PN-Z-04008-7:2002/AZ1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"工作场所环境检测实验室","methodology_zh":"职业接触评估采样，针对："},{"_id":"6a82cc4c884ede9a1b2c2dd7","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźniki narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźniki narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002/AZ1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002/AZ1:2004"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźniki narażenia (z obliczeń) PN-Z-04008-7:2002 | PN-Z-04008-7:2002/AZ1:2004 Srodowisko pracy - powietrze Wskazniki narazenia (z obliczen) PN-Z-04008-7:2002 | PN-Z-04008-7:2002/AZ1:2004","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Exposure indices (calculated)","search_en":"Workplace environment - air Exposure indices (calculated) Workplace Environment Testing Laboratory PN-Z-04008-7:2002 | PN-Z-04008-7:2002/AZ1:2004","test_object_en":"Workplace environment - air","search_zh":"工作场所环境 — 空气 暴露指数（计算值） 工作场所环境检测实验室 PN-Z-04008-7:2002 | PN-Z-04008-7:2002/AZ1:2004","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"工作场所环境检测实验室","methodology_zh":"暴露指数（计算值）"},{"_id":"6a82cc4c884ede9a1b2c2dd8","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia","parameters":[{"name":"frakcja wdychalna"},{"name":"pyły drewna"},{"name":"pyły niesklasyfikowane ze względu na toksyczność"},{"name":"pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Zakres","range":"(0,07– 20,42) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia\nZakres:\nfrakcja wdychalna\npyły drewna\npyły niesklasyfikowane ze względu na toksyczność\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nZakres (0,07– 20,42) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04504:2022-05","norm_bases":["PN-Z-04504:2022-05"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia\nZakres:\nfrakcja wdychalna\npyły drewna\npyły niesklasyfikowane ze względu na toksyczność\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nZakres (0,07– 20,42) mg/m3\nMetoda grawimetryczna PN-Z-04504:2022-05 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia\nZakres:\nfrakcja wdychalna\npyly drewna\npyly niesklasyfikowane ze wzgledu na toksycznosc\npyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nZakres (0,07– 20,42) mg/m3\nMetoda grawimetryczna PN-Z-04504:2022-05","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Concentration of harmful dust agents","parameters_en":[{"name":"inhalable fraction"},{"name":"wood dusts"},{"name":"dusts not classified according to toxicity"},{"name":"organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Range","range":"(0,07– 20,42) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents Gravimetric method Workplace Environment Testing Laboratory inhalable fraction wood dusts dusts not classified according to toxicity organic dusts of animal and plant origin, excluding wood and flour dusts Range PN-Z-04504:2022-05","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"可吸入组分"},{"name":"木粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"范围","range":"(0,07– 20,42) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害健康的粉尘因子浓度 重量法 工作场所环境检测实验室 可吸入组分 木粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 范围 PN-Z-04504:2022-05","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"工作场所环境检测实验室","methodology_zh":"有害健康的粉尘因子浓度"},{"_id":"6a82cc4c884ede9a1b2c2dd9","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia","parameters":[{"name":"frakcja respirabilna"},{"name":"pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Zakres","range":"(0,02 – 18,56) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia\nZakres:\nfrakcja respirabilna\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nZakres (0,02 – 18,56) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05","norm_bases":["PN-Z-04508:2022-05"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia\nZakres:\nfrakcja respirabilna\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nZakres (0,02 – 18,56) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia\nZakres:\nfrakcja respirabilna\npyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nZakres (0,02 – 18,56) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Concentration of harmful dust agents","parameters_en":[{"name":"respirable fraction"},{"name":"organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Range","range":"(0,02 – 18,56) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents Gravimetric method Workplace Environment Testing Laboratory respirable fraction organic dusts of animal and plant origin, excluding wood and flour dusts Range PN-Z-04508:2022-05","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"呼吸性组分"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"范围","range":"(0,02 – 18,56) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害健康的粉尘因子浓度 重量法 工作场所环境检测实验室 呼吸性组分 动植物来源有机粉尘，木粉和面粉除外 范围 PN-Z-04508:2022-05","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"工作场所环境检测实验室","methodology_zh":"有害健康的粉尘因子浓度"},{"_id":"6a82cc4c884ede9a1b2c2dda","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne po- chodzące od urządzeń stosowa- nych w technice medycznej: - diatermie chirurgiczne, - diatermie fizykoterapeutyczne","methodology":"Natężenie pola elektrycznego","parameters":[{"name":"w paśmie częstotliwości: 10Hz – 400kHz"},{"name":"Zakres","range":"1V/m - 30kV/m"},{"name":"w paśmie częstotliwości 100 kHz – 50 GHz"},{"name":"Zakres","range":"0,5 V/m – 250 V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego\nZakres:\nw paśmie częstotliwości: 10Hz – 400kHz\nZakres 1V/m - 30kV/m\nw paśmie częstotliwości 100 kHz – 50 GHz\nZakres 0,5 V/m – 250 V/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 | Metoda dostosowana do obszaru Regulowanego | IR-LBŚP-05/PO-10 wyd. nr 2 z dnia 16.01.2020 r.","norm_bases":["PN-T-06580-3:2002","Metoda dostosowana do obszaru Regulowanego","IR-LBŚP-05/PO-10 wyd. nr 2 z dnia 16.01.2020 r."],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne po- chodzące od urządzeń stosowa- nych w technice medycznej: - diatermie chirurgiczne, - diatermie fizykoterapeutyczne Natężenie pola elektrycznego\nZakres:\nw paśmie częstotliwości: 10Hz – 400kHz\nZakres 1V/m - 30kV/m\nw paśmie częstotliwości 100 kHz – 50 GHz\nZakres 0,5 V/m – 250 V/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 | Metoda dostosowana do obszaru Regulowanego | IR-LBŚP-05/PO-10 wyd. nr 2 z dnia 16.01.2020 r. Srodowisko pracy - pole elektromagnetyczne po- chodzace od urzadzen stosowa- nych w technice medycznej: - diatermie chirurgiczne, - diatermie fizykoterapeutyczne Natezenie pola elektrycznego\nZakres:\nw pasmie czestotliwosci: 10Hz – 400kHz\nZakres 1V/m - 30kV/m\nw pasmie czestotliwosci 100 kHz – 50 GHz\nZakres 0,5 V/m – 250 V/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 | Metoda dostosowana do obszaru Regulowanego | IR-LBSP-05/PO-10 wyd. nr 2 z dnia 16.01.2020 r.","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Electric field strength","parameters_en":[{"name":"w paśmie częstotliwości: 10Hz – 400kHz"},{"name":"Range","range":"1V/m - 30kV/m"},{"name":"w paśmie częstotliwości 100 kHz – 50 GHz"},{"name":"Range","range":"0,5 V/m – 250 V/m"}],"search_en":"Electric field strength Direct measurement method Workplace Environment Testing Laboratory Range Range PN-T-06580-3:2002 | Metoda dostosowana do obszaru Regulowanego | IR-LBŚP-05/PO-10 wyd. nr 2 z dnia 16.01.2020 r.","technique_en":"Direct measurement method","parameters_zh":[{"name":"w paśmie częstotliwości: 10Hz – 400kHz"},{"name":"范围","range":"1V/m - 30kV/m"},{"name":"w paśmie częstotliwości 100 kHz – 50 GHz"},{"name":"范围","range":"0,5 V/m – 250 V/m"}],"search_zh":"电场强度 直接测量法 工作场所环境检测实验室 范围 范围 PN-T-06580-3:2002 | Metoda dostosowana do obszaru Regulowanego | IR-LBŚP-05/PO-10 wyd. nr 2 z dnia 16.01.2020 r.","technique_zh":"直接测量法","lab_section_zh":"工作场所环境检测实验室","methodology_zh":"电场强度"},{"_id":"6a82cc4c884ede9a1b2c2ddb","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne po- chodzące od urządzeń stosowa- nych w technice medycznej: - diatermie chirurgiczne, - diatermie fizykoterapeutyczne","methodology":"Natężenie pola magnetycznego","parameters":[{"name":"w paśmie częstotliwości: 10Hz – 400kHz"},{"name":"Zakres","range":"0,8 A/m - 8kA/m"},{"name":"w paśmie częstotliwości 100kHz - 1GHz"},{"name":"Zakres","range":"0,015 A/m - 8 A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego\nZakres:\nw paśmie częstotliwości: 10Hz – 400kHz\nZakres 0,8 A/m - 8kA/m\nw paśmie częstotliwości 100kHz - 1GHz\nZakres 0,015 A/m - 8 A/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 | Metoda dostosowana do obszaru Regulowanego | IR-LBŚP-05/PO-10 wyd. nr 2 z dnia 16.01.2020 r.","norm_bases":["PN-T-06580-3:2002","Metoda dostosowana do obszaru Regulowanego","IR-LBŚP-05/PO-10 wyd. nr 2 z dnia 16.01.2020 r."],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne po- chodzące od urządzeń stosowa- nych w technice medycznej: - diatermie chirurgiczne, - diatermie fizykoterapeutyczne Natężenie pola magnetycznego\nZakres:\nw paśmie częstotliwości: 10Hz – 400kHz\nZakres 0,8 A/m - 8kA/m\nw paśmie częstotliwości 100kHz - 1GHz\nZakres 0,015 A/m - 8 A/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 | Metoda dostosowana do obszaru Regulowanego | IR-LBŚP-05/PO-10 wyd. nr 2 z dnia 16.01.2020 r. Srodowisko pracy - pole elektromagnetyczne po- chodzace od urzadzen stosowa- nych w technice medycznej: - diatermie chirurgiczne, - diatermie fizykoterapeutyczne Natezenie pola magnetycznego\nZakres:\nw pasmie czestotliwosci: 10Hz – 400kHz\nZakres 0,8 A/m - 8kA/m\nw pasmie czestotliwosci 100kHz - 1GHz\nZakres 0,015 A/m - 8 A/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 | Metoda dostosowana do obszaru Regulowanego | IR-LBSP-05/PO-10 wyd. nr 2 z dnia 16.01.2020 r.","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Magnetic field strength","parameters_en":[{"name":"w paśmie częstotliwości: 10Hz – 400kHz"},{"name":"Range","range":"0,8 A/m - 8kA/m"},{"name":"w paśmie częstotliwości 100kHz - 1GHz"},{"name":"Range","range":"0,015 A/m - 8 A/m"}],"search_en":"Magnetic field strength Direct measurement method Workplace Environment Testing Laboratory Range Range PN-T-06580-3:2002 | Metoda dostosowana do obszaru Regulowanego | IR-LBŚP-05/PO-10 wyd. nr 2 z dnia 16.01.2020 r.","technique_en":"Direct measurement method","parameters_zh":[{"name":"w paśmie częstotliwości: 10Hz – 400kHz"},{"name":"范围","range":"0,8 A/m - 8kA/m"},{"name":"w paśmie częstotliwości 100kHz - 1GHz"},{"name":"范围","range":"0,015 A/m - 8 A/m"}],"search_zh":"磁场强度 直接测量法 工作场所环境检测实验室 范围 范围 PN-T-06580-3:2002 | Metoda dostosowana do obszaru Regulowanego | IR-LBŚP-05/PO-10 wyd. nr 2 z dnia 16.01.2020 r.","technique_zh":"直接测量法","lab_section_zh":"工作场所环境检测实验室","methodology_zh":"磁场强度"},{"_id":"6a82cc4c884ede9a1b2c2ddc","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne po- chodzące od urządzeń stosowa- nych w technice medycznej: - diatermie chirurgiczne, - diatermie fizykoterapeutyczne","methodology":"Natężenie pola magnetycznego w paśmie częstotliwości:","parameters":[{"name":"1GHz – 3GHz (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego w paśmie częstotliwości:\n1GHz – 3GHz (z obliczeń)","reference":"PN-T-06580-3:2002 | Metoda dostosowana do obszaru Regulowanego | IR-LBŚP-05/PO-10 wyd. nr 2 z dnia 16.01.2020 r.","norm_bases":["PN-T-06580-3:2002","Metoda dostosowana do obszaru Regulowanego","IR-LBŚP-05/PO-10 wyd. nr 2 z dnia 16.01.2020 r."],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne po- chodzące od urządzeń stosowa- nych w technice medycznej: - diatermie chirurgiczne, - diatermie fizykoterapeutyczne Natężenie pola magnetycznego w paśmie częstotliwości:\n1GHz – 3GHz (z obliczeń) PN-T-06580-3:2002 | Metoda dostosowana do obszaru Regulowanego | IR-LBŚP-05/PO-10 wyd. nr 2 z dnia 16.01.2020 r. Srodowisko pracy - pole elektromagnetyczne po- chodzace od urzadzen stosowa- nych w technice medycznej: - diatermie chirurgiczne, - diatermie fizykoterapeutyczne Natezenie pola magnetycznego w pasmie czestotliwosci:\n1GHz – 3GHz (z obliczen) PN-T-06580-3:2002 | Metoda dostosowana do obszaru Regulowanego | IR-LBSP-05/PO-10 wyd. nr 2 z dnia 16.01.2020 r.","categories":["environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Magnetic field strength in the frequency band:","search_en":"Magnetic field strength in the frequency band: Workplace Environment Testing Laboratory PN-T-06580-3:2002 | Metoda dostosowana do obszaru Regulowanego | IR-LBŚP-05/PO-10 wyd. nr 2 z dnia 16.01.2020 r.","lab_section_zh":"工作场所环境检测实验室","search_zh":"下列频段内的磁场强度： 工作场所环境检测实验室 PN-T-06580-3:2002 | Metoda dostosowana do obszaru Regulowanego | IR-LBŚP-05/PO-10 wyd. nr 2 z dnia 16.01.2020 r.","methodology_zh":"下列频段内的磁场强度："},{"_id":"6a82cc4c884ede9a1b2c2ddd","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od stacjonarnych urządzeń łączności","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości od 10 Hz – 400 kHz"},{"name":"Zakres","range":"1 V/m – 50 kV/m"},{"name":"w zakresie częstotliwości od 100 kHz – 18 GHz"},{"name":"Zakres","range":"(0,5 – 800) V/m"},{"name":"w zakresie częstotliwości od 27 MHz – 60 GHz"},{"name":"Zakres","range":"(1 – 300) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz – 400 kHz\nZakres 1 V/m – 50 kV/m\nw zakresie częstotliwości od 100 kHz – 18 GHz\nZakres (0,5 – 800) V/m\nw zakresie częstotliwości od 27 MHz – 60 GHz\nZakres (1 – 300) V/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022","norm_bases":["NO-06-A215-2:2022"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów Decyzji Nr 171/MON Ministra Obrony Narodowej z dnia 27.10.2017 r. (Dz.Urz. MON z 2017 r. poz.208 z późn.zm.).","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od stacjonarnych urządzeń łączności Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz – 400 kHz\nZakres 1 V/m – 50 kV/m\nw zakresie częstotliwości od 100 kHz – 18 GHz\nZakres (0,5 – 800) V/m\nw zakresie częstotliwości od 27 MHz – 60 GHz\nZakres (1 – 300) V/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzace od stacjonarnych urzadzen lacznosci Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 10 Hz – 400 kHz\nZakres 1 V/m – 50 kV/m\nw zakresie czestotliwosci od 100 kHz – 18 GHz\nZakres (0,5 – 800) V/m\nw zakresie czestotliwosci od 27 MHz – 60 GHz\nZakres (1 – 300) V/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Electric field strength:","parameters_en":[{"name":"w zakresie częstotliwości od 10 Hz – 400 kHz"},{"name":"Range","range":"1 V/m – 50 kV/m"},{"name":"w zakresie częstotliwości od 100 kHz – 18 GHz"},{"name":"Range","range":"(0,5 – 800) V/m"},{"name":"w zakresie częstotliwości od 27 MHz – 60 GHz"},{"name":"Range","range":"(1 – 300) V/m"}],"search_en":"Workplace environment – electromagnetic field in the workspace from stationary communication devices Electric field strength: Direct measurement method Workplace Environment Testing Laboratory Range Range Range NO-06-A215-2:2022","technique_en":"Direct measurement method","test_object_en":"Workplace environment – electromagnetic field in the workspace from stationary communication devices","methodology_zh":"电场强度：","parameters_zh":[{"name":"w zakresie częstotliwości od 10 Hz – 400 kHz"},{"name":"范围","range":"1 V/m – 50 kV/m"},{"name":"w zakresie częstotliwości od 100 kHz – 18 GHz"},{"name":"范围","range":"(0,5 – 800) V/m"},{"name":"w zakresie częstotliwości od 27 MHz – 60 GHz"},{"name":"范围","range":"(1 – 300) V/m"}],"search_zh":"工作环境 － 作业空间内由固定式通信设备产生的电磁场 电场强度： 直接测量法 工作场所环境检测实验室 范围 范围 范围 NO-06-A215-2:2022","technique_zh":"直接测量法","lab_section_zh":"工作场所环境检测实验室","test_object_zh":"工作环境 － 作业空间内由固定式通信设备产生的电磁场"},{"_id":"6a82cc4c884ede9a1b2c2dde","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od stacjonarnych urządzeń łączności","methodology":"Natężenie pola magnetycznego","parameters":[{"name":"od 100 kHz – 30 MHz"},{"name":"Zakres","range":"(0,01 – 16) A/m"},{"name":"od 20 MHz – 1 GHz"},{"name":"Zakres","range":"(0,01 – 12) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego\nZakres:\nod 100 kHz – 30 MHz\nZakres (0,01 – 16) A/m\nod 20 MHz – 1 GHz\nZakres (0,01 – 12) A/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022","norm_bases":["NO-06-A215-2:2022"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów Decyzji Nr 171/MON Ministra Obrony Narodowej z dnia 27.10.2017 r. (Dz.Urz. MON z 2017 r. poz.208 z późn.zm.).","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od stacjonarnych urządzeń łączności Natężenie pola magnetycznego\nZakres:\nod 100 kHz – 30 MHz\nZakres (0,01 – 16) A/m\nod 20 MHz – 1 GHz\nZakres (0,01 – 12) A/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzace od stacjonarnych urzadzen lacznosci Natezenie pola magnetycznego\nZakres:\nod 100 kHz – 30 MHz\nZakres (0,01 – 16) A/m\nod 20 MHz – 1 GHz\nZakres (0,01 – 12) A/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Magnetic field strength","parameters_en":[{"name":"od 100 kHz – 30 MHz"},{"name":"Range","range":"(0,01 – 16) A/m"},{"name":"od 20 MHz – 1 GHz"},{"name":"Range","range":"(0,01 – 12) A/m"}],"search_en":"Workplace environment – electromagnetic field in the workspace from stationary communication devices Magnetic field strength Direct measurement method Workplace Environment Testing Laboratory Range Range NO-06-A215-2:2022","technique_en":"Direct measurement method","test_object_en":"Workplace environment – electromagnetic field in the workspace from stationary communication devices","parameters_zh":[{"name":"od 100 kHz – 30 MHz"},{"name":"范围","range":"(0,01 – 16) A/m"},{"name":"od 20 MHz – 1 GHz"},{"name":"范围","range":"(0,01 – 12) A/m"}],"search_zh":"工作环境 － 作业空间内由固定式通信设备产生的电磁场 磁场强度 直接测量法 工作场所环境检测实验室 范围 范围 NO-06-A215-2:2022","technique_zh":"直接测量法","lab_section_zh":"工作场所环境检测实验室","methodology_zh":"磁场强度","test_object_zh":"工作环境 － 作业空间内由固定式通信设备产生的电磁场"},{"_id":"6a82cc4c884ede9a1b2c2ddf","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od stacjonarnych urządzeń łączności","methodology":"Natężenie pola magnetycznego","parameters":[{"name":"od 1 GHz – 3 GHz ( z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego\nod 1 GHz – 3 GHz ( z obliczeń)","reference":"NO-06-A215-2:2022","norm_bases":["NO-06-A215-2:2022"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów Decyzji Nr 171/MON Ministra Obrony Narodowej z dnia 27.10.2017 r. (Dz.Urz. MON z 2017 r. poz.208 z późn.zm.).","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od stacjonarnych urządzeń łączności Natężenie pola magnetycznego\nod 1 GHz – 3 GHz ( z obliczeń) NO-06-A215-2:2022 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzace od stacjonarnych urzadzen lacznosci Natezenie pola magnetycznego\nod 1 GHz – 3 GHz ( z obliczen) NO-06-A215-2:2022","categories":["environment"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Magnetic field strength","search_en":"Workplace environment – electromagnetic field in the workspace from stationary communication devices Magnetic field strength Workplace Environment Testing Laboratory NO-06-A215-2:2022","test_object_en":"Workplace environment – electromagnetic field in the workspace from stationary communication devices","lab_section_zh":"工作场所环境检测实验室","search_zh":"工作环境 － 作业空间内由固定式通信设备产生的电磁场 磁场强度 工作场所环境检测实验室 NO-06-A215-2:2022","methodology_zh":"磁场强度","test_object_zh":"工作环境 － 作业空间内由固定式通信设备产生的电磁场"},{"_id":"6a82cc4c884ede9a1b2c2de0","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od mobilnych urządzeń łączności","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości od 10 Hz – 400 kHz"},{"name":"Zakres","range":"1 V/m – 50 kV/m"},{"name":"w zakresie częstotliwości od 100 kHz – 18 GHz"},{"name":"Zakres","range":"(0,5 – 800) V/m"},{"name":"w zakresie częstotliwości od 27 MHz – 60 GHz"},{"name":"Zakres","range":"(1 – 300) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz – 400 kHz\nZakres 1 V/m – 50 kV/m\nw zakresie częstotliwości od 100 kHz – 18 GHz\nZakres (0,5 – 800) V/m\nw zakresie częstotliwości od 27 MHz – 60 GHz\nZakres (1 – 300) V/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022","norm_bases":["NO-06-A215-2:2022"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów Decyzji Nr 171/MON Ministra Obrony Narodowej z dnia 27.10.2017 r. (Dz.Urz. MON z 2017 r. poz.208 z późn.zm.).","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od mobilnych urządzeń łączności Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz – 400 kHz\nZakres 1 V/m – 50 kV/m\nw zakresie częstotliwości od 100 kHz – 18 GHz\nZakres (0,5 – 800) V/m\nw zakresie częstotliwości od 27 MHz – 60 GHz\nZakres (1 – 300) V/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzace od mobilnych urzadzen lacznosci Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 10 Hz – 400 kHz\nZakres 1 V/m – 50 kV/m\nw zakresie czestotliwosci od 100 kHz – 18 GHz\nZakres (0,5 – 800) V/m\nw zakresie czestotliwosci od 27 MHz – 60 GHz\nZakres (1 – 300) V/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022","categories":["environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Electric field strength:","parameters_en":[{"name":"w zakresie częstotliwości od 10 Hz – 400 kHz"},{"name":"Range","range":"1 V/m – 50 kV/m"},{"name":"w zakresie częstotliwości od 100 kHz – 18 GHz"},{"name":"Range","range":"(0,5 – 800) V/m"},{"name":"w zakresie częstotliwości od 27 MHz – 60 GHz"},{"name":"Range","range":"(1 – 300) V/m"}],"search_en":"Workplace environment – electromagnetic field in the workspace from mobile communication devices Electric field strength: Direct measurement method Workplace Environment Testing Laboratory Range Range Range NO-06-A215-2:2022","technique_en":"Direct measurement method","test_object_en":"Workplace environment – electromagnetic field in the workspace from mobile communication devices","methodology_zh":"电场强度：","parameters_zh":[{"name":"w zakresie częstotliwości od 10 Hz – 400 kHz"},{"name":"范围","range":"1 V/m – 50 kV/m"},{"name":"w zakresie częstotliwości od 100 kHz – 18 GHz"},{"name":"范围","range":"(0,5 – 800) V/m"},{"name":"w zakresie częstotliwości od 27 MHz – 60 GHz"},{"name":"范围","range":"(1 – 300) V/m"}],"search_zh":"工作环境 － 作业空间内由移动通信设备产生的电磁场 电场强度： 直接测量法 工作场所环境检测实验室 范围 范围 范围 NO-06-A215-2:2022","technique_zh":"直接测量法","lab_section_zh":"工作场所环境检测实验室","test_object_zh":"工作环境 － 作业空间内由移动通信设备产生的电磁场"},{"_id":"6a82cc4c884ede9a1b2c2de1","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od mobilnych urządzeń łączności","methodology":"Natężenie pola magnetycznego","parameters":[{"name":"od 100 kHz – 30 MHz"},{"name":"Zakres","range":"(0,01 – 16) A/m"},{"name":"od 20 MHz – 1 GHz"},{"name":"Zakres","range":"(0,01 – 12) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego\nZakres:\nod 100 kHz – 30 MHz\nZakres (0,01 – 16) A/m\nod 20 MHz – 1 GHz\nZakres (0,01 – 12) A/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022","norm_bases":["NO-06-A215-2:2022"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów Decyzji Nr 171/MON Ministra Obrony Narodowej z dnia 27.10.2017 r. (Dz.Urz. MON z 2017 r. poz.208 z późn.zm.).","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od mobilnych urządzeń łączności Natężenie pola magnetycznego\nZakres:\nod 100 kHz – 30 MHz\nZakres (0,01 – 16) A/m\nod 20 MHz – 1 GHz\nZakres (0,01 – 12) A/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzace od mobilnych urzadzen lacznosci Natezenie pola magnetycznego\nZakres:\nod 100 kHz – 30 MHz\nZakres (0,01 – 16) A/m\nod 20 MHz – 1 GHz\nZakres (0,01 – 12) A/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022","categories":["environment"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Magnetic field strength","parameters_en":[{"name":"od 100 kHz – 30 MHz"},{"name":"Range","range":"(0,01 – 16) A/m"},{"name":"od 20 MHz – 1 GHz"},{"name":"Range","range":"(0,01 – 12) A/m"}],"search_en":"Workplace environment – electromagnetic field in the workspace from mobile communication devices Magnetic field strength Direct measurement method Workplace Environment Testing Laboratory Range Range NO-06-A215-2:2022","technique_en":"Direct measurement method","test_object_en":"Workplace environment – electromagnetic field in the workspace from mobile communication devices","parameters_zh":[{"name":"od 100 kHz – 30 MHz"},{"name":"范围","range":"(0,01 – 16) A/m"},{"name":"od 20 MHz – 1 GHz"},{"name":"范围","range":"(0,01 – 12) A/m"}],"search_zh":"工作环境 － 作业空间内由移动通信设备产生的电磁场 磁场强度 直接测量法 工作场所环境检测实验室 范围 范围 NO-06-A215-2:2022","technique_zh":"直接测量法","lab_section_zh":"工作场所环境检测实验室","methodology_zh":"磁场强度","test_object_zh":"工作环境 － 作业空间内由移动通信设备产生的电磁场"},{"_id":"6a82cc4c884ede9a1b2c2de2","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od mobilnych urządzeń łączności","methodology":"Natężenie pola magnetycznego","parameters":[{"name":"od 1 GHz – 3 GHz ( z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego\nod 1 GHz – 3 GHz ( z obliczeń)","reference":"NO-06-A215-2:2022","norm_bases":["NO-06-A215-2:2022"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów Decyzji Nr 171/MON Ministra Obrony Narodowej z dnia 27.10.2017 r. (Dz.Urz. MON z 2017 r. poz.208 z późn.zm.).","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od mobilnych urządzeń łączności Natężenie pola magnetycznego\nod 1 GHz – 3 GHz ( z obliczeń) NO-06-A215-2:2022 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzace od mobilnych urzadzen lacznosci Natezenie pola magnetycznego\nod 1 GHz – 3 GHz ( z obliczen) NO-06-A215-2:2022","categories":["environment"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Magnetic field strength","search_en":"Workplace environment – electromagnetic field in the workspace from mobile communication devices Magnetic field strength Workplace Environment Testing Laboratory NO-06-A215-2:2022","test_object_en":"Workplace environment – electromagnetic field in the workspace from mobile communication devices","lab_section_zh":"工作场所环境检测实验室","search_zh":"工作环境 － 作业空间内由移动通信设备产生的电磁场 磁场强度 工作场所环境检测实验室 NO-06-A215-2:2022","methodology_zh":"磁场强度","test_object_zh":"工作环境 － 作业空间内由移动通信设备产生的电磁场"},{"_id":"6a82cc4c884ede9a1b2c2de3","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od pojazdów ze środkami łączności","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości od 10 Hz – 400 kHz"},{"name":"Zakres","range":"1 V/m – 50 kV/m"},{"name":"w zakresie częstotliwości od 100 kHz – 18 GHz"},{"name":"Zakres","range":"(0,5 – 800) V/m"},{"name":"w zakresie częstotliwości od 27 MHz – 60 GHz"},{"name":"Zakres","range":"(1 – 300) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz – 400 kHz\nZakres 1 V/m – 50 kV/m\nw zakresie częstotliwości od 100 kHz – 18 GHz\nZakres (0,5 – 800) V/m\nw zakresie częstotliwości od 27 MHz – 60 GHz\nZakres (1 – 300) V/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022","norm_bases":["NO-06-A215-2:2022"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów Decyzji Nr 171/MON Ministra Obrony Narodowej z dnia 27.10.2017 r. (Dz.Urz. MON z 2017 r. poz.208 z późn.zm.).","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od pojazdów ze środkami łączności Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz – 400 kHz\nZakres 1 V/m – 50 kV/m\nw zakresie częstotliwości od 100 kHz – 18 GHz\nZakres (0,5 – 800) V/m\nw zakresie częstotliwości od 27 MHz – 60 GHz\nZakres (1 – 300) V/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzace od pojazdow ze srodkami lacznosci Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 10 Hz – 400 kHz\nZakres 1 V/m – 50 kV/m\nw zakresie czestotliwosci od 100 kHz – 18 GHz\nZakres (0,5 – 800) V/m\nw zakresie czestotliwosci od 27 MHz – 60 GHz\nZakres (1 – 300) V/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022","categories":["environment","automotive"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Electric field strength:","parameters_en":[{"name":"w zakresie częstotliwości od 10 Hz – 400 kHz"},{"name":"Range","range":"1 V/m – 50 kV/m"},{"name":"w zakresie częstotliwości od 100 kHz – 18 GHz"},{"name":"Range","range":"(0,5 – 800) V/m"},{"name":"w zakresie częstotliwości od 27 MHz – 60 GHz"},{"name":"Range","range":"(1 – 300) V/m"}],"search_en":"Workplace environment – electromagnetic field in the workspace from vehicles with communication equipment Electric field strength: Direct measurement method Workplace Environment Testing Laboratory Range Range Range NO-06-A215-2:2022","technique_en":"Direct measurement method","test_object_en":"Workplace environment – electromagnetic field in the workspace from vehicles with communication equipment","methodology_zh":"电场强度：","parameters_zh":[{"name":"w zakresie częstotliwości od 10 Hz – 400 kHz"},{"name":"范围","range":"1 V/m – 50 kV/m"},{"name":"w zakresie częstotliwości od 100 kHz – 18 GHz"},{"name":"范围","range":"(0,5 – 800) V/m"},{"name":"w zakresie częstotliwości od 27 MHz – 60 GHz"},{"name":"范围","range":"(1 – 300) V/m"}],"search_zh":"工作环境 － 作业空间内由载有通信设备的车辆产生的电磁场 电场强度： 直接测量法 工作场所环境检测实验室 范围 范围 范围 NO-06-A215-2:2022","technique_zh":"直接测量法","lab_section_zh":"工作场所环境检测实验室","test_object_zh":"工作环境 － 作业空间内由载有通信设备的车辆产生的电磁场"},{"_id":"6a82cc4c884ede9a1b2c2de4","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od pojazdów ze środkami łączności","methodology":"Natężenie pola magnetycznego","parameters":[{"name":"od 100 kHz – 30 MHz"},{"name":"Zakres","range":"(0,01 – 16) A/m"},{"name":"od 20 MHz – 1 GHz"},{"name":"Zakres","range":"(0,01 – 12) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego\nZakres:\nod 100 kHz – 30 MHz\nZakres (0,01 – 16) A/m\nod 20 MHz – 1 GHz\nZakres (0,01 – 12) A/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022","norm_bases":["NO-06-A215-2:2022"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów Decyzji Nr 171/MON Ministra Obrony Narodowej z dnia 27.10.2017 r. (Dz.Urz. MON z 2017 r. poz.208 z późn.zm.).","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od pojazdów ze środkami łączności Natężenie pola magnetycznego\nZakres:\nod 100 kHz – 30 MHz\nZakres (0,01 – 16) A/m\nod 20 MHz – 1 GHz\nZakres (0,01 – 12) A/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzace od pojazdow ze srodkami lacznosci Natezenie pola magnetycznego\nZakres:\nod 100 kHz – 30 MHz\nZakres (0,01 – 16) A/m\nod 20 MHz – 1 GHz\nZakres (0,01 – 12) A/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022","categories":["environment","automotive"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Magnetic field strength","parameters_en":[{"name":"od 100 kHz – 30 MHz"},{"name":"Range","range":"(0,01 – 16) A/m"},{"name":"od 20 MHz – 1 GHz"},{"name":"Range","range":"(0,01 – 12) A/m"}],"search_en":"Workplace environment – electromagnetic field in the workspace from vehicles with communication equipment Magnetic field strength Direct measurement method Workplace Environment Testing Laboratory Range Range NO-06-A215-2:2022","technique_en":"Direct measurement method","test_object_en":"Workplace environment – electromagnetic field in the workspace from vehicles with communication equipment","parameters_zh":[{"name":"od 100 kHz – 30 MHz"},{"name":"范围","range":"(0,01 – 16) A/m"},{"name":"od 20 MHz – 1 GHz"},{"name":"范围","range":"(0,01 – 12) A/m"}],"search_zh":"工作环境 － 作业空间内由载有通信设备的车辆产生的电磁场 磁场强度 直接测量法 工作场所环境检测实验室 范围 范围 NO-06-A215-2:2022","technique_zh":"直接测量法","lab_section_zh":"工作场所环境检测实验室","methodology_zh":"磁场强度","test_object_zh":"工作环境 － 作业空间内由载有通信设备的车辆产生的电磁场"},{"_id":"6a82cc4c884ede9a1b2c2de5","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od pojazdów ze środkami łączności","methodology":"Natężenie pola magnetycznego","parameters":[{"name":"od 1 GHz – 3 GHz ( z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego\nod 1 GHz – 3 GHz ( z obliczeń)","reference":"NO-06-A215-2:2022","norm_bases":["NO-06-A215-2:2022"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów Decyzji Nr 171/MON Ministra Obrony Narodowej z dnia 27.10.2017 r. (Dz.Urz. MON z 2017 r. poz.208 z późn.zm.).","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od pojazdów ze środkami łączności Natężenie pola magnetycznego\nod 1 GHz – 3 GHz ( z obliczeń) NO-06-A215-2:2022 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzace od pojazdow ze srodkami lacznosci Natezenie pola magnetycznego\nod 1 GHz – 3 GHz ( z obliczen) NO-06-A215-2:2022","categories":["environment","automotive"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Magnetic field strength","search_en":"Workplace environment – electromagnetic field in the workspace from vehicles with communication equipment Magnetic field strength Workplace Environment Testing Laboratory NO-06-A215-2:2022","test_object_en":"Workplace environment – electromagnetic field in the workspace from vehicles with communication equipment","lab_section_zh":"工作场所环境检测实验室","search_zh":"工作环境 － 作业空间内由载有通信设备的车辆产生的电磁场 磁场强度 工作场所环境检测实验室 NO-06-A215-2:2022","methodology_zh":"磁场强度","test_object_zh":"工作环境 － 作业空间内由载有通信设备的车辆产生的电磁场"},{"_id":"6a82cc4c884ede9a1b2c2de6","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od doręcznych i przenośnych środków łączności.","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości od 10 Hz – 400 kHz"},{"name":"Zakres","range":"1 V/m – 50 kV/m"},{"name":"w zakresie częstotliwości od 100 kHz – 18 GHz"},{"name":"Zakres","range":"(0,5 – 800) V/m"},{"name":"w zakresie częstotliwości od 27 MHz – 60 GHz"},{"name":"Zakres","range":"(1 – 300) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz – 400 kHz\nZakres 1 V/m – 50 kV/m\nw zakresie częstotliwości od 100 kHz – 18 GHz\nZakres (0,5 – 800) V/m\nw zakresie częstotliwości od 27 MHz – 60 GHz\nZakres (1 – 300) V/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022","norm_bases":["NO-06-A215-2:2022"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów Decyzji Nr 171/MON Ministra Obrony Narodowej z dnia 27.10.2017 r. (Dz.Urz. MON z 2017 r. poz.208 z późn.zm.).","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od doręcznych i przenośnych środków łączności. Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz – 400 kHz\nZakres 1 V/m – 50 kV/m\nw zakresie częstotliwości od 100 kHz – 18 GHz\nZakres (0,5 – 800) V/m\nw zakresie częstotliwości od 27 MHz – 60 GHz\nZakres (1 – 300) V/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzace od dorecznych i przenosnych srodkow lacznosci. Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 10 Hz – 400 kHz\nZakres 1 V/m – 50 kV/m\nw zakresie czestotliwosci od 100 kHz – 18 GHz\nZakres (0,5 – 800) V/m\nw zakresie czestotliwosci od 27 MHz – 60 GHz\nZakres (1 – 300) V/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022","categories":["environment"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Electric field strength:","parameters_en":[{"name":"w zakresie częstotliwości od 10 Hz – 400 kHz"},{"name":"Range","range":"1 V/m – 50 kV/m"},{"name":"w zakresie częstotliwości od 100 kHz – 18 GHz"},{"name":"Range","range":"(0,5 – 800) V/m"},{"name":"w zakresie częstotliwości od 27 MHz – 60 GHz"},{"name":"Range","range":"(1 – 300) V/m"}],"search_en":"Workplace environment – electromagnetic field in the workspace from hand-held and portable communication devices. Electric field strength: Direct measurement method Workplace Environment Testing Laboratory Range Range Range NO-06-A215-2:2022","technique_en":"Direct measurement method","test_object_en":"Workplace environment – electromagnetic field in the workspace from hand-held and portable communication devices.","methodology_zh":"电场强度：","parameters_zh":[{"name":"w zakresie częstotliwości od 10 Hz – 400 kHz"},{"name":"范围","range":"1 V/m – 50 kV/m"},{"name":"w zakresie częstotliwości od 100 kHz – 18 GHz"},{"name":"范围","range":"(0,5 – 800) V/m"},{"name":"w zakresie częstotliwości od 27 MHz – 60 GHz"},{"name":"范围","range":"(1 – 300) V/m"}],"search_zh":"工作环境 － 作业空间内由手持式与便携式通信设备产生的电磁场。 电场强度： 直接测量法 工作场所环境检测实验室 范围 范围 范围 NO-06-A215-2:2022","technique_zh":"直接测量法","lab_section_zh":"工作场所环境检测实验室","test_object_zh":"工作环境 － 作业空间内由手持式与便携式通信设备产生的电磁场。"},{"_id":"6a82cc4c884ede9a1b2c2de7","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od doręcznych i przenośnych środków łączności.","methodology":"Natężenie pola magnetycznego","parameters":[{"name":"od 100 kHz – 30 MHz"},{"name":"Zakres","range":"(0,01 – 16) A/m"},{"name":"od 20 MHz – 1 GHz"},{"name":"Zakres","range":"(0,01 – 12) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego\nZakres:\nod 100 kHz – 30 MHz\nZakres (0,01 – 16) A/m\nod 20 MHz – 1 GHz\nZakres (0,01 – 12) A/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022","norm_bases":["NO-06-A215-2:2022"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów Decyzji Nr 171/MON Ministra Obrony Narodowej z dnia 27.10.2017 r. (Dz.Urz. MON z 2017 r. poz.208 z późn.zm.).","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od doręcznych i przenośnych środków łączności. Natężenie pola magnetycznego\nZakres:\nod 100 kHz – 30 MHz\nZakres (0,01 – 16) A/m\nod 20 MHz – 1 GHz\nZakres (0,01 – 12) A/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzace od dorecznych i przenosnych srodkow lacznosci. Natezenie pola magnetycznego\nZakres:\nod 100 kHz – 30 MHz\nZakres (0,01 – 16) A/m\nod 20 MHz – 1 GHz\nZakres (0,01 – 12) A/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022","categories":["environment"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Magnetic field strength","parameters_en":[{"name":"od 100 kHz – 30 MHz"},{"name":"Range","range":"(0,01 – 16) A/m"},{"name":"od 20 MHz – 1 GHz"},{"name":"Range","range":"(0,01 – 12) A/m"}],"search_en":"Workplace environment – electromagnetic field in the workspace from hand-held and portable communication devices. Magnetic field strength Direct measurement method Workplace Environment Testing Laboratory Range Range NO-06-A215-2:2022","technique_en":"Direct measurement method","test_object_en":"Workplace environment – electromagnetic field in the workspace from hand-held and portable communication devices.","parameters_zh":[{"name":"od 100 kHz – 30 MHz"},{"name":"范围","range":"(0,01 – 16) A/m"},{"name":"od 20 MHz – 1 GHz"},{"name":"范围","range":"(0,01 – 12) A/m"}],"search_zh":"工作环境 － 作业空间内由手持式与便携式通信设备产生的电磁场。 磁场强度 直接测量法 工作场所环境检测实验室 范围 范围 NO-06-A215-2:2022","technique_zh":"直接测量法","lab_section_zh":"工作场所环境检测实验室","methodology_zh":"磁场强度","test_object_zh":"工作环境 － 作业空间内由手持式与便携式通信设备产生的电磁场。"},{"_id":"6a82cc4c884ede9a1b2c2de8","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od doręcznych i przenośnych środków łączności.","methodology":"Natężenie pola magnetycznego","parameters":[{"name":"od 1 GHz – 3 GHz (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego\nod 1 GHz – 3 GHz (z obliczeń)","reference":"NO-06-A215-2:2022","norm_bases":["NO-06-A215-2:2022"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów Decyzji Nr 171/MON Ministra Obrony Narodowej z dnia 27.10.2017 r. (Dz.Urz. MON z 2017 r. poz.208 z późn.zm.).","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od doręcznych i przenośnych środków łączności. Natężenie pola magnetycznego\nod 1 GHz – 3 GHz (z obliczeń) NO-06-A215-2:2022 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzace od dorecznych i przenosnych srodkow lacznosci. Natezenie pola magnetycznego\nod 1 GHz – 3 GHz (z obliczen) NO-06-A215-2:2022","categories":["environment"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Magnetic field strength","search_en":"Workplace environment – electromagnetic field in the workspace from hand-held and portable communication devices. Magnetic field strength Workplace Environment Testing Laboratory NO-06-A215-2:2022","test_object_en":"Workplace environment – electromagnetic field in the workspace from hand-held and portable communication devices.","lab_section_zh":"工作场所环境检测实验室","search_zh":"工作环境 － 作业空间内由手持式与便携式通信设备产生的电磁场。 磁场强度 工作场所环境检测实验室 NO-06-A215-2:2022","methodology_zh":"磁场强度","test_object_zh":"工作环境 － 作业空间内由手持式与便携式通信设备产生的电磁场。"},{"_id":"6a82cc4c884ede9a1b2c2de9","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od aparatury kontrolno-pomiarowej.","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości od 10 Hz – 400 kHz"},{"name":"Zakres","range":"1 V/m – 50 kV/m"},{"name":"w zakresie częstotliwości od 100 kHz – 18 GHz"},{"name":"Zakres","range":"(0,5 – 800) V/m"},{"name":"w zakresie częstotliwości od 27 MHz – 60 GHz"},{"name":"Zakres","range":"(1 – 300) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz – 400 kHz\nZakres 1 V/m – 50 kV/m\nw zakresie częstotliwości od 100 kHz – 18 GHz\nZakres (0,5 – 800) V/m\nw zakresie częstotliwości od 27 MHz – 60 GHz\nZakres (1 – 300) V/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022","norm_bases":["NO-06-A215-2:2022"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów Decyzji Nr 171/MON Ministra Obrony Narodowej z dnia 27.10.2017 r. (Dz.Urz. MON z 2017 r. poz.208 z późn.zm.).","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od aparatury kontrolno-pomiarowej. Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz – 400 kHz\nZakres 1 V/m – 50 kV/m\nw zakresie częstotliwości od 100 kHz – 18 GHz\nZakres (0,5 – 800) V/m\nw zakresie częstotliwości od 27 MHz – 60 GHz\nZakres (1 – 300) V/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzace od aparatury kontrolno-pomiarowej. Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 10 Hz – 400 kHz\nZakres 1 V/m – 50 kV/m\nw zakresie czestotliwosci od 100 kHz – 18 GHz\nZakres (0,5 – 800) V/m\nw zakresie czestotliwosci od 27 MHz – 60 GHz\nZakres (1 – 300) V/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022","categories":["environment"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Electric field strength:","parameters_en":[{"name":"w zakresie częstotliwości od 10 Hz – 400 kHz"},{"name":"Range","range":"1 V/m – 50 kV/m"},{"name":"w zakresie częstotliwości od 100 kHz – 18 GHz"},{"name":"Range","range":"(0,5 – 800) V/m"},{"name":"w zakresie częstotliwości od 27 MHz – 60 GHz"},{"name":"Range","range":"(1 – 300) V/m"}],"search_en":"Workplace environment – electromagnetic field in the workspace from control and measuring apparatus. Electric field strength: Direct measurement method Workplace Environment Testing Laboratory Range Range Range NO-06-A215-2:2022","technique_en":"Direct measurement method","test_object_en":"Workplace environment – electromagnetic field in the workspace from control and measuring apparatus.","methodology_zh":"电场强度：","parameters_zh":[{"name":"w zakresie częstotliwości od 10 Hz – 400 kHz"},{"name":"范围","range":"1 V/m – 50 kV/m"},{"name":"w zakresie częstotliwości od 100 kHz – 18 GHz"},{"name":"范围","range":"(0,5 – 800) V/m"},{"name":"w zakresie częstotliwości od 27 MHz – 60 GHz"},{"name":"范围","range":"(1 – 300) V/m"}],"search_zh":"工作环境 － 作业空间内由检测与测量仪器产生的电磁场。 电场强度： 直接测量法 工作场所环境检测实验室 范围 范围 范围 NO-06-A215-2:2022","technique_zh":"直接测量法","lab_section_zh":"工作场所环境检测实验室","test_object_zh":"工作环境 － 作业空间内由检测与测量仪器产生的电磁场。"},{"_id":"6a82cc4c884ede9a1b2c2dea","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od aparatury kontrolno-pomiarowej.","methodology":"Natężenie pola magnetycznego","parameters":[{"name":"od 100 kHz – 30 MHz"},{"name":"Zakres","range":"(0,01 – 16) A/m"},{"name":"od 20 MHz – 1 GHz"},{"name":"Zakres","range":"(0,01 – 12) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego\nZakres:\nod 100 kHz – 30 MHz\nZakres (0,01 – 16) A/m\nod 20 MHz – 1 GHz\nZakres (0,01 – 12) A/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022","norm_bases":["NO-06-A215-2:2022"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów Decyzji Nr 171/MON Ministra Obrony Narodowej z dnia 27.10.2017 r. (Dz.Urz. MON z 2017 r. poz.208 z późn.zm.).","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od aparatury kontrolno-pomiarowej. Natężenie pola magnetycznego\nZakres:\nod 100 kHz – 30 MHz\nZakres (0,01 – 16) A/m\nod 20 MHz – 1 GHz\nZakres (0,01 – 12) A/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzace od aparatury kontrolno-pomiarowej. Natezenie pola magnetycznego\nZakres:\nod 100 kHz – 30 MHz\nZakres (0,01 – 16) A/m\nod 20 MHz – 1 GHz\nZakres (0,01 – 12) A/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022","categories":["environment"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Magnetic field strength","parameters_en":[{"name":"od 100 kHz – 30 MHz"},{"name":"Range","range":"(0,01 – 16) A/m"},{"name":"od 20 MHz – 1 GHz"},{"name":"Range","range":"(0,01 – 12) A/m"}],"search_en":"Workplace environment – electromagnetic field in the workspace from control and measuring apparatus. Magnetic field strength Direct measurement method Workplace Environment Testing Laboratory Range Range NO-06-A215-2:2022","technique_en":"Direct measurement method","test_object_en":"Workplace environment – electromagnetic field in the workspace from control and measuring apparatus.","parameters_zh":[{"name":"od 100 kHz – 30 MHz"},{"name":"范围","range":"(0,01 – 16) A/m"},{"name":"od 20 MHz – 1 GHz"},{"name":"范围","range":"(0,01 – 12) A/m"}],"search_zh":"工作环境 － 作业空间内由检测与测量仪器产生的电磁场。 磁场强度 直接测量法 工作场所环境检测实验室 范围 范围 NO-06-A215-2:2022","technique_zh":"直接测量法","lab_section_zh":"工作场所环境检测实验室","methodology_zh":"磁场强度","test_object_zh":"工作环境 － 作业空间内由检测与测量仪器产生的电磁场。"},{"_id":"6a82cc4c884ede9a1b2c2deb","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od aparatury kontrolno-pomiarowej.","methodology":"Natężenie pola magnetycznego","parameters":[{"name":"od 1 GHz – 3 GHz (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego\nod 1 GHz – 3 GHz (z obliczeń)","reference":"NO-06-A215-2:2022","norm_bases":["NO-06-A215-2:2022"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów Decyzji Nr 171/MON Ministra Obrony Narodowej z dnia 27.10.2017 r. (Dz.Urz. MON z 2017 r. poz.208 z późn.zm.).","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od aparatury kontrolno-pomiarowej. Natężenie pola magnetycznego\nod 1 GHz – 3 GHz (z obliczeń) NO-06-A215-2:2022 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzace od aparatury kontrolno-pomiarowej. Natezenie pola magnetycznego\nod 1 GHz – 3 GHz (z obliczen) NO-06-A215-2:2022","categories":["environment"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Magnetic field strength","search_en":"Workplace environment – electromagnetic field in the workspace from control and measuring apparatus. Magnetic field strength Workplace Environment Testing Laboratory NO-06-A215-2:2022","test_object_en":"Workplace environment – electromagnetic field in the workspace from control and measuring apparatus.","lab_section_zh":"工作场所环境检测实验室","search_zh":"工作环境 － 作业空间内由检测与测量仪器产生的电磁场。 磁场强度 工作场所环境检测实验室 NO-06-A215-2:2022","methodology_zh":"磁场强度","test_object_zh":"工作环境 － 作业空间内由检测与测量仪器产生的电磁场。"},{"_id":"6a82cc4c884ede9a1b2c2dec","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii","methodology":"Indukcja pola magnetycznego w zakresie częstotliwości od 10 Hz do 400 Hz","parameters":[{"name":"zakres","range":"1 µT – 19 mT"}],"technique":"Metoda pomiarowa bezpośrednia (uproszczona).","techniques":["Metoda pomiarowa bezpośrednia (uproszczona)."],"computed":[],"activity":"Indukcja pola magnetycznego w zakresie częstotliwości od 10 Hz do 400 Hz\nzakres 1 µT – 19 mT\nMetoda pomiarowa bezpośrednia (uproszczona).","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s.151–180","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s.151–180"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego Potwierdzone kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz.331).","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii Indukcja pola magnetycznego w zakresie częstotliwości od 10 Hz do 400 Hz\nzakres 1 µT – 19 mT\nMetoda pomiarowa bezpośrednia (uproszczona). Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s.151–180 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen do magnetoterapii Indukcja pola magnetycznego w zakresie czestotliwosci od 10 Hz do 400 Hz\nzakres 1 µT – 19 mT\nMetoda pomiarowa bezposrednia (uproszczona). Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s.151–180","categories":["environment"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","parameters_en":[{"name":"range","range":"1 µT – 19 mT"}],"search_en":"Workplace environment – electromagnetic field in the workspace from magnetotherapy devices Workplace Environment Testing Laboratory range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s.151–180","test_object_en":"Workplace environment – electromagnetic field in the workspace from magnetotherapy devices","lab_section_zh":"工作场所环境检测实验室","parameters_zh":[{"name":"范围","range":"1 µT – 19 mT"}],"search_zh":"工作环境 － 作业空间内由磁疗设备产生的电磁场 工作场所环境检测实验室 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s.151–180","test_object_zh":"工作环境 － 作业空间内由磁疗设备产生的电磁场"},{"_id":"6a82cc4c884ede9a1b2c2ded","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"Liczba Enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) Liczba Enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda (w tym woda na plywalniach) Liczba Enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Intestinal enterococci count","search_en":"Water (including swimming pool water) Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water)","search_zh":"水（含游泳池水） 粪肠球菌数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）","methodology_zh":"粪肠球菌数"},{"_id":"6a82cc4c884ede9a1b2c2dee","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"Ogólna liczba mikroorganizmów w 22°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 22°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) Ogólna liczba mikroorganizmów w 22°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda (w tym woda na plywalniach) Ogolna liczba mikroorganizmow w 22°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 22°C","search_en":"Water (including swimming pool water) Total viable count at 22°C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water (including swimming pool water)","methodology_zh":"22°C 微生物总数","search_zh":"水（含游泳池水） 22°C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水（含游泳池水）"},{"_id":"6a82cc4c884ede9a1b2c2def","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"Ogólna liczba mikroorganizmów w 36°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 36°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) Ogólna liczba mikroorganizmów w 36°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda (w tym woda na plywalniach) Ogolna liczba mikroorganizmow w 36°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 36°C","search_en":"Water (including swimming pool water) Total viable count at 36°C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water (including swimming pool water)","methodology_zh":"36°C 微生物总数","search_zh":"水（含游泳池水） 36°C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水（含游泳池水）"},{"_id":"6a82cc4c884ede9a1b2c2df0","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda (w tym woda na plywalniach) Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pseudomonas aeruginosa count","search_en":"Water (including swimming pool water) Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water)","methodology_zh":"铜绿假单胞菌计数","search_zh":"水（含游泳池水） 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）"},{"_id":"6a82cc4c884ede9a1b2c2df1","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda (w tym woda na plywalniach) Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of coliform bacteria","search_en":"Water (including swimming pool water) Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water (including swimming pool water)","methodology_zh":"大肠菌群最可能数（MPN）","search_zh":"水（含游泳池水） 大肠菌群最可能数（MPN） 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水（含游泳池水）"},{"_id":"6a82cc4c884ede9a1b2c2df2","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"Najbardziej prawdopodobna liczba Escherichia coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) Najbardziej prawdopodobna liczba Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda (w tym woda na plywalniach) Najbardziej prawdopodobna liczba Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of Escherichia coli","search_en":"Water (including swimming pool water) Most probable number of Escherichia coli MPN method PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water (including swimming pool water)","search_zh":"水（含游泳池水） 大肠埃希氏菌最可能数 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水（含游泳池水）","methodology_zh":"大肠埃希氏菌最可能数"},{"_id":"6a82cc4c884ede9a1b2c2df3","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba Clostridium perfringens","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Clostridium perfringens\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":"Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba Clostridium perfringens\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda do spozycia przez ludzi Liczba Clostridium perfringens\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Clostridium perfringens count","search_en":"Water intended for human consumption Clostridium perfringens count Membrane filtration method PN-EN ISO 14189:2016-10","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 产气荚膜梭菌计数 膜过滤法 PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","test_object_zh":"生活饮用水","methodology_zh":"产气荚膜梭菌计数"},{"_id":"6a82cc4c884ede9a1b2c2df4","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12/A1:2017-04"],"lab_section":"Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04 Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","categories":["water","microbiology"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","methodology_zh":"大肠菌群计数","search_zh":"生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a82cc4c884ede9a1b2c2df5","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12/A1:2017-04"],"lab_section":"Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04 Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","categories":["water","microbiology"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count","search_en":"Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a82cc4c884ede9a1b2c2df6","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,05-0,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,05-0,5) mg/l\nMetoda spektrofotometryczna","reference":"PB-LBŻiW -02 wyd. 4 z dnia 05.02.2020 r. | na podstawie metody HACH 8008","norm_bases":["PB-LBŻiW -02 wyd. 4 z dnia 05.02.2020 r.","na podstawie metody HACH 8008"],"lab_section":"Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie żelaza ogólnego\nZakres (0,05-0,5) mg/l\nMetoda spektrofotometryczna PB-LBŻiW -02 wyd. 4 z dnia 05.02.2020 r. | na podstawie metody HACH 8008 Woda Stezenie zelaza ogolnego\nZakres (0,05-0,5) mg/l\nMetoda spektrofotometryczna PB-LBZiW -02 wyd. 4 z dnia 05.02.2020 r. | na podstawie metody HACH 8008","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,05-0,5) mg/l"}],"search_en":"Water Total iron concentration Spectrophotometric method Range PB-LBŻiW -02 wyd. 4 z dnia 05.02.2020 r. | na podstawie metody HACH 8008","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,05-0,5) mg/l"}],"search_zh":"水 总铁浓度 分光光度法 范围 PB-LBŻiW -02 wyd. 4 z dnia 05.02.2020 r. | na podstawie metody HACH 8008","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a82cc4c884ede9a1b2c2df7","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie amoniaku (jonu amonowego)","parameters":[{"name":"Zakres","range":"(0,05-1,03) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie amoniaku (jonu amonowego)\nZakres (0,05-1,03) mg/l\nMetoda spektrofotometryczna","reference":"PB-LBŻiW -01 wyd. 4 z dnia 05.02.2020 r. | na podstawie metody HACH 8038","norm_bases":["PB-LBŻiW -01 wyd. 4 z dnia 05.02.2020 r.","na podstawie metody HACH 8038"],"lab_section":"Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie amoniaku (jonu amonowego)\nZakres (0,05-1,03) mg/l\nMetoda spektrofotometryczna PB-LBŻiW -01 wyd. 4 z dnia 05.02.2020 r. | na podstawie metody HACH 8038 Woda Stezenie amoniaku (jonu amonowego)\nZakres (0,05-1,03) mg/l\nMetoda spektrofotometryczna PB-LBZiW -01 wyd. 4 z dnia 05.02.2020 r. | na podstawie metody HACH 8038","categories":["water"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonia (ammonium ion) concentration","parameters_en":[{"name":"Range","range":"(0,05-1,03) mg/l"}],"search_en":"Water Ammonia (ammonium ion) concentration Spectrophotometric method Range PB-LBŻiW -01 wyd. 4 z dnia 05.02.2020 r. | na podstawie metody HACH 8038","technique_en":"Spectrophotometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,05-1,03) mg/l"}],"search_zh":"水 分光光度法 范围 PB-LBŻiW -01 wyd. 4 z dnia 05.02.2020 r. | na podstawie metody HACH 8038","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a82cc4c884ede9a1b2c2df8","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Woda","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 – 40) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (5 – 40) mg/l Pt\nMetoda spektrofotometryczna","reference":"PB-LBŻiW-08 wyd. 4 z dnia 05.02.2020 r. | na podstawie metody HACH 8025","norm_bases":["PB-LBŻiW-08 wyd. 4 z dnia 05.02.2020 r.","na podstawie metody HACH 8025"],"lab_section":"Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Barwa\nZakres (5 – 40) mg/l Pt\nMetoda spektrofotometryczna PB-LBŻiW-08 wyd. 4 z dnia 05.02.2020 r. | na podstawie metody HACH 8025 Woda Barwa\nZakres (5 – 40) mg/l Pt\nMetoda spektrofotometryczna PB-LBZiW-08 wyd. 4 z dnia 05.02.2020 r. | na podstawie metody HACH 8025","categories":["water"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 – 40) mg/l Pt"}],"search_en":"Water Colour Spectrophotometric method Range PB-LBŻiW-08 wyd. 4 z dnia 05.02.2020 r. | na podstawie metody HACH 8025","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 40) mg/l Pt"}],"search_zh":"水 色度 分光光度法 范围 PB-LBŻiW-08 wyd. 4 z dnia 05.02.2020 r. | na podstawie metody HACH 8025","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a82cc4c884ede9a1b2c2df9","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Woda","methodology":"pH","parameters":[{"name":"Zakres","range":"(4,0 – 10,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (4,0 – 10,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda pH\nZakres (4,0 – 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda pH\nZakres (4,0 – 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"(4,0 – 10,0)"}],"search_en":"Water pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(4,0 – 10,0)"}],"search_zh":"水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水"},{"_id":"6a82cc4c884ede9a1b2c2dfa","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Woda","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 – 20) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 – 20) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Mętność\nZakres (0,10 – 20) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda Metnosc\nZakres (0,10 – 20) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,10 – 20) NTU"}],"search_en":"Water Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 – 20) NTU"}],"search_zh":"水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水"},{"_id":"6a82cc4c884ede9a1b2c2dfb","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,050-0,800) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,050-0,800) mg/l\nMetoda spektrofotometryczna","reference":"PB-LBŻiW-04 Wyd. 5 z dnia 05.02.2020 r. | na podstawie metody HACH 8507","norm_bases":["PB-LBŻiW-04 Wyd. 5 z dnia 05.02.2020 r.","na podstawie metody HACH 8507"],"lab_section":"Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotynów\nZakres (0,050-0,800) mg/l\nMetoda spektrofotometryczna PB-LBŻiW-04 Wyd. 5 z dnia 05.02.2020 r. | na podstawie metody HACH 8507 Woda Stezenie azotynow\nZakres (0,050-0,800) mg/l\nMetoda spektrofotometryczna PB-LBZiW-04 Wyd. 5 z dnia 05.02.2020 r. | na podstawie metody HACH 8507","categories":["water"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,050-0,800) mg/l"}],"search_en":"Water Nitrite concentration Spectrophotometric method Range PB-LBŻiW-04 Wyd. 5 z dnia 05.02.2020 r. | na podstawie metody HACH 8507","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,050-0,800) mg/l"}],"search_zh":"水 亚硝酸盐浓度 分光光度法 范围 PB-LBŻiW-04 Wyd. 5 z dnia 05.02.2020 r. | na podstawie metody HACH 8507","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a82cc4c884ede9a1b2c2dfc","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Woda","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(148-2500) µS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (148-2500) µS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Przewodność elektryczna właściwa\nZakres (148-2500) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda Przewodnosc elektryczna wlasciwa\nZakres (148-2500) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(148-2500) µS/cm"}],"search_en":"Water Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(148-2500) µS/cm"}],"search_zh":"水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水"},{"_id":"6a82cc4c884ede9a1b2c2dfd","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,50-50) mg/l"}],"technique":"Metoda chromatografii jonowej","techniques":["Metoda chromatografii jonowej"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,50-50) mg/l\nMetoda chromatografii jonowej","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotanów\nZakres (0,50-50) mg/l\nMetoda chromatografii jonowej PN-EN ISO 10304-1:2009+AC:2012 Woda Stezenie azotanow\nZakres (0,50-50) mg/l\nMetoda chromatografii jonowej PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(0,50-50) mg/l"}],"search_en":"Water Nitrate concentration Ion chromatography method Range PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography method","test_object_en":"Water","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,50-50) mg/l"}],"search_zh":"水 硝酸盐浓度 离子色谱法 范围 PN-EN ISO 10304-1:2009+AC:2012","test_object_zh":"水","technique_zh":"离子色谱法"},{"_id":"6a82cc4c884ede9a1b2c2dfe","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,010-0,50) mg/l"}],"technique":"Metoda chromatografii jonowej","techniques":["Metoda chromatografii jonowej"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,010-0,50) mg/l\nMetoda chromatografii jonowej","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotynów\nZakres (0,010-0,50) mg/l\nMetoda chromatografii jonowej PN-EN ISO 10304-1:2009+AC:2012 Woda Stezenie azotynow\nZakres (0,010-0,50) mg/l\nMetoda chromatografii jonowej PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,010-0,50) mg/l"}],"search_en":"Water Nitrite concentration Ion chromatography method Range PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography method","test_object_en":"Water","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,010-0,50) mg/l"}],"search_zh":"水 亚硝酸盐浓度 离子色谱法 范围 PN-EN ISO 10304-1:2009+AC:2012","test_object_zh":"水","technique_zh":"离子色谱法"},{"_id":"6a82cc4c884ede9a1b2c2dff","lab_id":"69ad52a3de79e566650fb628","country":"PL","accr_number":"AB 1197","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 -250) mg/l"}],"technique":"Metoda chromatografii jonowej","techniques":["Metoda chromatografii jonowej"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 -250) mg/l\nMetoda chromatografii jonowej","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie chlorków\nZakres (5,0 -250) mg/l\nMetoda chromatografii jonowej PN-EN ISO 10304-1:2009+AC:2012 Woda Stezenie chlorkow\nZakres (5,0 -250) mg/l\nMetoda chromatografii jonowej PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 -250) mg/l"}],"search_en":"Water Chloride concentration Ion chromatography method Range PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography method","test_object_en":"Water","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 -250) mg/l"}],"search_zh":"水 氯化物浓度 离子色谱法 范围 PN-EN ISO 10304-1:2009+AC:2012","test_object_zh":"水","technique_zh":"离子色谱法"}],"has_pdf":true}