{"lab":{"_id":"69ad52a3de79e566650fb626","accr_number":"AB 1196","country":"PL","accr_body":"PCA","address":"ODDZIAŁ W BYDGOSZCZY, DZIAŁ RUCHU GOSPODARKI WODNEJ, ul. Energetyczna 1","categories":["petro","environment"],"city":"Bydgoszcz","imported_at":"2026-03-08T10:42:43.265Z","methods_count":14,"name":"PGE ENERGIA CIEPŁA S.A.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1196.pdf"],"scope_summary":"","search_text":"pge energia ciepła s.a. oddział w bydgoszczy, dział ruchu gospodarki wodnej, ul. energetyczna 1 petro other materials pharma environment","status":"active","updated_at":"2026-03-08T14:50:22.796Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T08:46:54.159Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201196,podmiot.html","parse_date":"2026-08-17T08:46:54.159Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"C/4; C/10; C/32","pl":"Badania chemiczne wyrobów chemicznych, paliw stałych, odpadów","en":"Chemical tests of chemical products, solid fuels, waste"},{"codes":"N/4; N/10; N/32","pl":"Badania właściwości fizycznych wyrobów chemicznych, paliw stałych, odpadów","en":"Tests of physical properties of chemical products, solid fuels, waste"}],"issue":{"no":"22","date":"29.06.2026"},"map_coord":[53.101004,18.088719],"map_geo":"nominatim-street","lab_locations":[{"name":"ODDZIAŁ W BYDGOSZCZY","address":"ul. Energetyczna 1","city":"Bydgoszcz","postal":"85-950"},{"name":"DZIAŁ RUCHU GOSPODARKI WODNEJ","address":"ul. Energetyczna 1","city":"Bydgoszcz","postal":"85-950"},{"name":"Laboratorium Badań Fizyko-Chemicznych","address":"ul. Energetyczna 1, 85-950 Bydgoszcz","city":"Bydgoszcz","postal":"85-950"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/89c096e02b9d873504c4cbd5508d7f57/AB%201196.pdf","has_en":true,"category_counts":{"petro":12,"environment":1,"other":1},"category_scores":{"petro":10.29,"environment":0.07,"other":0.07},"has_zh":true},"methods":[{"_id":"6a82ca7e884ede9a1b2c2d9a","lab_id":"69ad52a3de79e566650fb626","country":"PL","accr_number":"AB 1196","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci przemijającej","parameters":[{"name":"Zakres","range":"(1,0 – 40,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci przemijającej\nZakres (1,0 – 40,0) %\nMetoda wagowa","reference":"PN-80/G-04511","norm_bases":["PN-80/G-04511"],"lab_section":"Laboratorium Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci przemijającej\nZakres (1,0 – 40,0) %\nMetoda wagowa PN-80/G-04511 Paliwa stale: wegiel kamienny Zawartosc wilgoci przemijajacej\nZakres (1,0 – 40,0) %\nMetoda wagowa PN-80/G-04511","categories":["petro"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free moisture content","parameters_en":[{"name":"Range","range":"(1,0 – 40,0) %"}],"search_en":"Solid fuels: hard coal Free moisture content Gravimetric method Range PN-80/G-04511","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(1,0 – 40,0) %"}],"search_zh":"固体燃料：烟煤 外在水分含量 重量法 范围 PN-80/G-04511","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"外在水分含量"},{"_id":"6a82ca7e884ede9a1b2c2d9b","lab_id":"69ad52a3de79e566650fb626","country":"PL","accr_number":"AB 1196","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci pierwszego stopnia (przemijającej)","parameters":[{"name":"Zakres","range":"(1,0 – 40,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci pierwszego stopnia (przemijającej)\nZakres (1,0 – 40,0) %\nMetoda wagowa","reference":"PN-ISO 589:2006","norm_bases":["PN-ISO 589:2006"],"lab_section":"Laboratorium Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci pierwszego stopnia (przemijającej)\nZakres (1,0 – 40,0) %\nMetoda wagowa PN-ISO 589:2006 Paliwa stale: wegiel kamienny Zawartosc wilgoci pierwszego stopnia (przemijajacej)\nZakres (1,0 – 40,0) %\nMetoda wagowa PN-ISO 589:2006","categories":["petro"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"First-stage (free) moisture content","parameters_en":[{"name":"Range","range":"(1,0 – 40,0) %"}],"search_en":"Solid fuels: hard coal First-stage (free) moisture content Gravimetric method Range PN-ISO 589:2006","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(1,0 – 40,0) %"}],"search_zh":"固体燃料：烟煤 第一阶段水分（外在水分）含量 重量法 范围 PN-ISO 589:2006","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"第一阶段水分（外在水分）含量"},{"_id":"6a82ca7e884ede9a1b2c2d9c","lab_id":"69ad52a3de79e566650fb626","country":"PL","accr_number":"AB 1196","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci w węglu powietrzno – suchym","parameters":[{"name":"Zakres","range":"(0,2 – 20,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w węglu powietrzno – suchym\nZakres (0,2 – 20,0) %\nMetoda wagowa","reference":"PN-80/G-04511","norm_bases":["PN-80/G-04511"],"lab_section":"Laboratorium Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w węglu powietrzno – suchym\nZakres (0,2 – 20,0) %\nMetoda wagowa PN-80/G-04511 Paliwa stale: wegiel kamienny Zawartosc wilgoci w weglu powietrzno – suchym\nZakres (0,2 – 20,0) %\nMetoda wagowa PN-80/G-04511","categories":["petro"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,2 – 20,0) %"}],"search_en":"Solid fuels: hard coal Gravimetric method Range PN-80/G-04511","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(0,2 – 20,0) %"}],"search_zh":"固体燃料：烟煤 重量法 范围 PN-80/G-04511","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a82ca7e884ede9a1b2c2d9d","lab_id":"69ad52a3de79e566650fb626","country":"PL","accr_number":"AB 1196","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci drugiego stopnia (wilgoci pozostałej w próbce)","parameters":[{"name":"Zakres","range":"(0,2 – 20,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci drugiego stopnia (wilgoci pozostałej w próbce)\nZakres (0,2 – 20,0) %\nMetoda wagowa","reference":"PN-ISO 589:2006 Metoda A1, A2","norm_bases":["PN-ISO 589:2006 Metoda A1, A2"],"lab_section":"Laboratorium Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci drugiego stopnia (wilgoci pozostałej w próbce)\nZakres (0,2 – 20,0) %\nMetoda wagowa PN-ISO 589:2006 Metoda A1, A2 Paliwa stale: wegiel kamienny Zawartosc wilgoci drugiego stopnia (wilgoci pozostalej w probce)\nZakres (0,2 – 20,0) %\nMetoda wagowa PN-ISO 589:2006 Metoda A1, A2","categories":["petro"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Second-stage moisture content (moisture remaining in the sample)","parameters_en":[{"name":"Range","range":"(0,2 – 20,0) %"}],"search_en":"Solid fuels: hard coal Second-stage moisture content (moisture remaining in the sample) Gravimetric method Range PN-ISO 589:2006 Metoda A1, A2","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(0,2 – 20,0) %"}],"search_zh":"固体燃料：烟煤 第二阶段水分（样品残余水分）含量 重量法 范围 PN-ISO 589:2006 Metoda A1, A2","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"第二阶段水分（样品残余水分）含量"},{"_id":"6a82ca7e884ede9a1b2c2d9e","lab_id":"69ad52a3de79e566650fb626","country":"PL","accr_number":"AB 1196","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,2 – 20,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,2 – 20,0) %\nMetoda wagowa","reference":"PN-80/G-04511 | PN-ISO 11722:2009","norm_bases":["PN-80/G-04511","PN-ISO 11722:2009"],"lab_section":"Laboratorium Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej\nZakres (0,2 – 20,0) %\nMetoda wagowa PN-80/G-04511 | PN-ISO 11722:2009 Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej\nZakres (0,2 – 20,0) %\nMetoda wagowa PN-80/G-04511 | PN-ISO 11722:2009","categories":["petro"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,2 – 20,0) %"}],"search_en":"Solid fuels: hard coal Moisture content in the analytical sample Gravimetric method Range PN-80/G-04511 | PN-ISO 11722:2009","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,2 – 20,0) %"}],"search_zh":"固体燃料：烟煤 分析样品水分含量 重量法 范围 PN-80/G-04511 | PN-ISO 11722:2009","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a82ca7e884ede9a1b2c2d9f","lab_id":"69ad52a3de79e566650fb626","country":"PL","accr_number":"AB 1196","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci całkowitej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wilgoci całkowitej (z obliczeń)","reference":"PN-80/G-04511 | PN-ISO 589:2006","norm_bases":["PN-80/G-04511","PN-ISO 589:2006"],"lab_section":"Laboratorium Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej (z obliczeń) PN-80/G-04511 | PN-ISO 589:2006 Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej (z obliczen) PN-80/G-04511 | PN-ISO 589:2006","categories":["petro"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content (calculated)","search_en":"Solid fuels: hard coal Total moisture content (calculated) PN-80/G-04511 | PN-ISO 589:2006","test_object_en":"Solid fuels: hard coal","search_zh":"固体燃料：烟煤 全水分含量（计算值） PN-80/G-04511 | PN-ISO 589:2006","test_object_zh":"固体燃料：烟煤","methodology_zh":"全水分含量（计算值）"},{"_id":"6a82ca7e884ede9a1b2c2da0","lab_id":"69ad52a3de79e566650fb626","country":"PL","accr_number":"AB 1196","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(1,0 – 60,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu\nZakres (1,0 – 60,0) %\nMetoda wagowa","reference":"PN-ISO 1171:2002","norm_bases":["PN-ISO 1171:2002"],"lab_section":"Laboratorium Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu\nZakres (1,0 – 60,0) %\nMetoda wagowa PN-ISO 1171:2002 Paliwa stale: wegiel kamienny Zawartosc popiolu\nZakres (1,0 – 60,0) %\nMetoda wagowa PN-ISO 1171:2002","categories":["petro"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(1,0 – 60,0) %"}],"search_en":"Solid fuels: hard coal Ash content Gravimetric method Range PN-ISO 1171:2002","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 60,0) %"}],"search_zh":"固体燃料：烟煤 灰分含量 重量法 范围 PN-ISO 1171:2002","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a82ca7e884ede9a1b2c2da1","lab_id":"69ad52a3de79e566650fb626","country":"PL","accr_number":"AB 1196","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(20,0 – 85,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres (20,0 – 85,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":"Laboratorium Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość węgla całkowitego\nZakres (20,0 – 85,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc wegla calkowitego\nZakres (20,0 – 85,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(20,0 – 85,0) %"}],"search_en":"Solid fuels: hard coal Total carbon content High-temperature combustion with IR detection Range PN-G-04571:1998","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(20,0 – 85,0) %"}],"search_zh":"固体燃料：烟煤 总碳含量 高温燃烧红外检测法 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a82ca7e884ede9a1b2c2da2","lab_id":"69ad52a3de79e566650fb626","country":"PL","accr_number":"AB 1196","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wodoru całkowitego","parameters":[{"name":"Zakres","range":"(2,00 – 5,50) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość wodoru całkowitego\nZakres (2,00 – 5,50) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":"Laboratorium Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wodoru całkowitego\nZakres (2,00 – 5,50) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc wodoru calkowitego\nZakres (2,00 – 5,50) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total hydrogen content","parameters_en":[{"name":"Range","range":"(2,00 – 5,50) %"}],"search_en":"Solid fuels: hard coal Total hydrogen content High-temperature combustion with IR detection Range PN-G-04571:1998","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(2,00 – 5,50) %"}],"search_zh":"固体燃料：烟煤 全氢含量 高温燃烧红外检测法 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤","methodology_zh":"全氢含量"},{"_id":"6a82ca7e884ede9a1b2c2da3","lab_id":"69ad52a3de79e566650fb626","country":"PL","accr_number":"AB 1196","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,10 – 2,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,10 – 2,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001 | ISO 19579:2006","norm_bases":["PN-G-04584:2001","ISO 19579:2006"],"lab_section":"Laboratorium Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość siarki całkowitej\nZakres (0,10 – 2,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 | ISO 19579:2006 Paliwa stale: wegiel kamienny Zawartosc siarki calkowitej\nZakres (0,10 – 2,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001 | ISO 19579:2006","categories":["petro"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,10 – 2,00) %"}],"search_en":"Solid fuels: hard coal Total sulfur content High-temperature combustion with IR detection Range PN-G-04584:2001 | ISO 19579:2006","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,10 – 2,00) %"}],"search_zh":"固体燃料：烟煤 全硫含量 高温燃烧红外检测法 范围 PN-G-04584:2001 | ISO 19579:2006","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a82ca7e884ede9a1b2c2da4","lab_id":"69ad52a3de79e566650fb626","country":"PL","accr_number":"AB 1196","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(10 000 – 35 000) kJ/kg"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres (10 000 – 35 000) kJ/kg\nMetoda kalorymetryczna","reference":"PN-81/G-04513 | PN-ISO 1928:2020-05","norm_bases":["PN-81/G-04513","PN-ISO 1928:2020-05"],"lab_section":"Laboratorium Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Ciepło spalania\nZakres (10 000 – 35 000) kJ/kg\nMetoda kalorymetryczna PN-81/G-04513 | PN-ISO 1928:2020-05 Paliwa stale: wegiel kamienny Cieplo spalania\nZakres (10 000 – 35 000) kJ/kg\nMetoda kalorymetryczna PN-81/G-04513 | PN-ISO 1928:2020-05","categories":["petro"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(10 000 – 35 000) kJ/kg"}],"search_en":"Solid fuels: hard coal Gross calorific value Calorimetric method Range PN-81/G-04513 | PN-ISO 1928:2020-05","technique_en":"Calorimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(10 000 – 35 000) kJ/kg"}],"search_zh":"固体燃料：烟煤 高位发热量 量热法 范围 PN-81/G-04513 | PN-ISO 1928:2020-05","technique_zh":"量热法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a82ca7e884ede9a1b2c2da5","lab_id":"69ad52a3de79e566650fb626","country":"PL","accr_number":"AB 1196","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Wartość opałowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość opałowa (z obliczeń)","reference":"PN-81/G-04513 | PN-ISO 1928:2020-05","norm_bases":["PN-81/G-04513","PN-ISO 1928:2020-05"],"lab_section":"Laboratorium Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Wartość opałowa (z obliczeń) PN-81/G-04513 | PN-ISO 1928:2020-05 Paliwa stale: wegiel kamienny Wartosc opalowa (z obliczen) PN-81/G-04513 | PN-ISO 1928:2020-05","categories":["petro"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net calorific value (calculated)","search_en":"Solid fuels: hard coal Net calorific value (calculated) PN-81/G-04513 | PN-ISO 1928:2020-05","test_object_en":"Solid fuels: hard coal","methodology_zh":"低位发热量（计算值）","search_zh":"固体燃料：烟煤 低位发热量（计算值） PN-81/G-04513 | PN-ISO 1928:2020-05","test_object_zh":"固体燃料：烟煤"},{"_id":"6a82ca7e884ede9a1b2c2da6","lab_id":"69ad52a3de79e566650fb626","country":"PL","accr_number":"AB 1196","accr_body":"PCA","test_object":"Odpady O): kod 10 01 01, 10 01 02, 10 01 80","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(0,10 – 40,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres (0,10 – 40,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"Procedura badawcza PB/OP-02 Wydanie 10 z dnia 01.10.2025 r.","norm_bases":["Procedura badawcza PB/OP-02 Wydanie 10 z dnia 01.10.2025 r."],"lab_section":"Laboratorium Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O): kod 10 01 01, 10 01 02, 10 01 80 Zawartość węgla całkowitego\nZakres (0,10 – 40,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR Procedura badawcza PB/OP-02 Wydanie 10 z dnia 01.10.2025 r. Odpady O): kod 10 01 01, 10 01 02, 10 01 80 Zawartosc wegla calkowitego\nZakres (0,10 – 40,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR Procedura badawcza PB/OP-02 Wydanie 10 z dnia 01.10.2025 r.","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(0,10 – 40,00) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Waste O): code 10 01 01, 10 01 02, 10 01 80 Total carbon content High-temperature combustion with IR detection waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range Procedura badawcza PB/OP-02 Wydanie 10 z dnia 01.10.2025 r.","technique_en":"High-temperature combustion with IR detection","test_object_en":"Waste O): code 10 01 01, 10 01 02, 10 01 80","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(0,10 – 40,00) %"}],"search_zh":"废物 O)：代码 10 01 01、10 01 02、10 01 80 总碳含量 高温燃烧红外检测法 依据气候部长关于废物目录的条例的废物代码。 范围 Procedura badawcza PB/OP-02 Wydanie 10 z dnia 01.10.2025 r.","technique_zh":"高温燃烧红外检测法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。","test_object_zh":"废物 O)：代码 10 01 01、10 01 02、10 01 80"},{"_id":"6a82ca7e884ede9a1b2c2da7","lab_id":"69ad52a3de79e566650fb626","country":"PL","accr_number":"AB 1196","accr_body":"PCA","test_object":"Popiół lotny, żużel","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,05 – 10,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,05 – 10,00) %\nMetoda wagowa","reference":"Procedura badawcza PB/OP-03 Wydanie 10 z dnia 01.10.2025 r.","norm_bases":["Procedura badawcza PB/OP-03 Wydanie 10 z dnia 01.10.2025 r."],"lab_section":"Laboratorium Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Popiół lotny, żużel Zawartość wilgoci w próbce analitycznej\nZakres (0,05 – 10,00) %\nMetoda wagowa Procedura badawcza PB/OP-03 Wydanie 10 z dnia 01.10.2025 r. Popiol lotny, zuzel Zawartosc wilgoci w probce analitycznej\nZakres (0,05 – 10,00) %\nMetoda wagowa Procedura badawcza PB/OP-03 Wydanie 10 z dnia 01.10.2025 r.","categories":["other"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,05 – 10,00) %"}],"search_en":"Moisture content in the analytical sample Gravimetric method Range Procedura badawcza PB/OP-03 Wydanie 10 z dnia 01.10.2025 r.","technique_en":"Gravimetric method","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,05 – 10,00) %"}],"search_zh":"分析样品水分含量 重量法 范围 Procedura badawcza PB/OP-03 Wydanie 10 z dnia 01.10.2025 r.","technique_zh":"重量法"}],"has_pdf":true}