{"lab":{"_id":"69ad52a3de79e566650fb125","accr_number":"AB 118","country":"PL","accr_body":"PCA","address":"ul. Chmielna 132/134, 00-805 Warszawa, CENTRALNE LABORATORIUM BADAWCZE, ODDZIAŁ W LUBLINIE","categories":["water","environment"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":57,"name":"GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_118.pdf"],"scope_summary":"","search_text":"główny inspektorat ochrony środowiska ul. chmielna 132/134, 00-805 warszawa, centralne laboratorium badawcze, oddział w lublinie environment metrology water other pharma electronics food petro materials","status":"active","updated_at":"2026-03-08T14:50:21.645Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T08:28:50.867Z","email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20118,podmiot.html","parse_date":"2026-08-17T08:28:50.867Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"C/28/P; C30/P","pl":"Badania chemiczne i pobieranie próbek wody, ścieków","en":"Chemical tests and sampling of water, sewage"},{"codes":"C/36/P","pl":"Badania chemiczne i pobieranie próbek gazów odlotowych","en":"Chemical tests and sampling of waste gases"},{"codes":"G/34; G/36","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) środowisko ogólne (czynniki fizyczne – hałas, pole elektromagnetyczne)","en":"Tests concerning environmental engineering (enviromental and climatic) – general environment (physical factors – noise, electromagnetic field)"},{"codes":"N/28/P; N/30/P; N/36/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, ścieków, gazów odlotowych","en":"Tests of physical properties and sampling of water, sewage, waste gases"},{"codes":"P/31; P/32","pl":"Pobieranie próbek gleby, osadów ściekowych, odpadów","en":"Sampling of soil, sediments, waste"}],"issue":{"no":"26","date":"02.07.2026"},"map_coord":[52.227738,20.992749],"map_geo":"nominatim-street","lab_locations":[{"name":"CENTRALNE LABORATORIUM BADAWCZE ODDZIAŁ W LUBLINIE","address":"ul. Obywatelska 13","city":"Lublin","postal":"20-092"},{"name":"Pracownia Terenowa","address":"ul. Obywatelska 13, 20-092 Lublin","city":"Lublin","postal":"20-092"},{"name":"Pracownia w Lublinie","address":"ul. Obywatelska 13, 20-092 Lublin","city":"Lublin","postal":"20-092"}],"scope_format":"PCA::pracownie+siatka5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/9715c71c2bbe95f19ec366165840dde2/AB%20118.pdf","has_en":true,"category_counts":{"water":37,"environment":15,"other":6,"materials":2,"petro":2,"microbiology":1},"category_scores":{"water":21.73,"environment":3.57,"other":0.57,"materials":0.06,"petro":0.06,"microbiology":0.02},"has_zh":true},"methods":[{"_id":"6a82c643884ede9a1b2c2906","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(24 – 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (24 – 135) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (24 – 135) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (24 – 135) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 7.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(24 – 135) dB"}],"search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Range Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F","technique_en":"Direct measurement method","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(24 – 135) dB"}],"search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 A 计权等效声级 直接测量法 范围 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F","technique_zh":"直接测量法","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"},{"_id":"6a82c643884ede9a1b2c2907","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 7.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"},{"_id":"6a82c643884ede9a1b2c2908","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","methodology":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(24 – 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (24 – 135) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. 2011 Nr 140, poz. 824) z wyłączeniem punktu H (Dz.U.2011 nr 288, poz. 1697)","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. 2011 Nr 140, poz. 824) z wyłączeniem punktu H (Dz.U.2011 nr 288, poz. 1697)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (24 – 135) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. 2011 Nr 140, poz. 824) z wyłączeniem punktu H (Dz.U.2011 nr 288, poz. 1697) Srodowisko ogolne – halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A Ekspozycyjny poziom dzwieku A\nZakres (24 – 135) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz.U. 2011 Nr 140, poz. 824) z wylaczeniem punktu H (Dz.U.2011 nr 288, poz. 1697)","categories":["environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level A-weighted sound exposure level","parameters_en":[{"name":"Range","range":"(24 – 135) dB"}],"search_en":"General environment – noise from roads, railway lines, tram lines A-weighted equivalent sound level A-weighted sound exposure level Direct measurement method Range Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. 2011 Nr 140, poz. 824) z wyłączeniem punktu H (Dz.U.2011 nr 288, poz. 1697)","technique_en":"Direct measurement method","test_object_en":"General environment – noise from roads, railway lines, tram lines","parameters_zh":[{"name":"范围","range":"(24 – 135) dB"}],"search_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声 A 计权等效声级 A 计权声暴露级 直接测量法 范围 Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. 2011 Nr 140, poz. 824) z wyłączeniem punktu H (Dz.U.2011 nr 288, poz. 1697)","technique_zh":"直接测量法","test_object_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声","methodology_zh":"A 计权等效声级 A 计权声暴露级"},{"_id":"6a82c643884ede9a1b2c2909","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. 2011 Nr 140, poz. 824) z wyłączeniem punktu H (Dz.U.2011 nr 288, poz. 1697)","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. 2011 Nr 140, poz. 824) z wyłączeniem punktu H (Dz.U.2011 nr 288, poz. 1697)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. 2011 Nr 140, poz. 824) z wyłączeniem punktu H (Dz.U.2011 nr 288, poz. 1697) Srodowisko ogolne – halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz.U. 2011 Nr 140, poz. 824) z wylaczeniem punktu H (Dz.U.2011 nr 288, poz. 1697)","categories":["environment"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment – noise from roads, railway lines, tram lines A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. 2011 Nr 140, poz. 824) z wyłączeniem punktu H (Dz.U.2011 nr 288, poz. 1697)","test_object_en":"General environment – noise from roads, railway lines, tram lines","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. 2011 Nr 140, poz. 824) z wyłączeniem punktu H (Dz.U.2011 nr 288, poz. 1697)","test_object_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声"},{"_id":"6a82c643884ede9a1b2c290a","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 z wył. pkt 7.5 i 7.6 | PN-ISO 5667-11:2017-10 z wył. pkt 5.2, 6.1.2, 6.2, 6.3","norm_bases":["PN-ISO 5667-4:2017-10","PN-EN ISO 5667-6:2016-12 z wył. pkt 7.5 i 7.6","PN-ISO 5667-11:2017-10 z wył. pkt 5.2, 6.1.2, 6.2, 6.3"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 z wył. pkt 7.5 i 7.6 | PN-ISO 5667-11:2017-10 z wył. pkt 5.2, 6.1.2, 6.2, 6.3 Woda Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 z wyl. pkt 7.5 i 7.6 | PN-ISO 5667-11:2017-10 z wyl. pkt 5.2, 6.1.2, 6.2, 6.3","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water Sampling for chemical and physical testing PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 z wył. pkt 7.5 i 7.6 | PN-ISO 5667-11:2017-10 z wył. pkt 5.2, 6.1.2, 6.2, 6.3","test_object_en":"Water","methodology_zh":"化学与物理检测用样品采集","search_zh":"水 化学与物理检测用样品采集 PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 z wył. pkt 7.5 i 7.6 | PN-ISO 5667-11:2017-10 z wył. pkt 5.2, 6.1.2, 6.2, 6.3","test_object_zh":"水"},{"_id":"6a82c643884ede9a1b2c290b","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Woda","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(0,0 – 50,0) ºC"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (0,0 – 50,0) ºC","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Temperatura\nZakres (0,0 – 50,0) ºC PN-77/C-04584 Woda Temperatura\nZakres (0,0 – 50,0) ºC PN-77/C-04584","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(0,0 – 50,0) ºC"}],"search_en":"Water Temperature Range PN-77/C-04584","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,0 – 50,0) ºC"}],"search_zh":"水 温度 范围 PN-77/C-04584","test_object_zh":"水","methodology_zh":"温度"},{"_id":"6a82c643884ede9a1b2c290c","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,2 – 17,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,2 – 17,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5814:2013-04","norm_bases":["PN-EN ISO 5814:2013-04"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie tlenu rozpuszczonego\nZakres (0,2 – 17,0) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04 Woda Stezenie tlenu rozpuszczonego\nZakres (0,2 – 17,0) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(0,2 – 17,0) mg/l O2"}],"search_en":"Water Dissolved oxygen concentration Electrochemical method Range PN-EN ISO 5814:2013-04","technique_en":"Electrochemical method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,2 – 17,0) mg/l O2"}],"search_zh":"水 溶解氧浓度 电化学法 范围 PN-EN ISO 5814:2013-04","technique_zh":"电化学法","test_object_zh":"水","methodology_zh":"溶解氧浓度"},{"_id":"6a82c643884ede9a1b2c290d","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,2 – 17,0) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,2 – 17,0) mg/l O2\nMetoda optyczna","reference":"ISO 17289:2014","norm_bases":["ISO 17289:2014"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie tlenu rozpuszczonego\nZakres (0,2 – 17,0) mg/l O2\nMetoda optyczna ISO 17289:2014 Woda Stezenie tlenu rozpuszczonego\nZakres (0,2 – 17,0) mg/l O2\nMetoda optyczna ISO 17289:2014","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(0,2 – 17,0) mg/l O2"}],"search_en":"Water Dissolved oxygen concentration Optical method Range ISO 17289:2014","technique_en":"Optical method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,2 – 17,0) mg/l O2"}],"search_zh":"水 溶解氧浓度 光学法 范围 ISO 17289:2014","technique_zh":"光学法","test_object_zh":"水","methodology_zh":"溶解氧浓度"},{"_id":"6a82c643884ede9a1b2c290e","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"(2,0 – 12,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (2,0 – 12,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki pH\nZakres (2,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki pH\nZakres (2,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"(2,0 – 12,0)"}],"search_en":"Water, wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(2,0 – 12,0)"}],"search_zh":"水、废水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、废水"},{"_id":"6a82c643884ede9a1b2c290f","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10,0 – 13000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (10,0 – 13000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Przewodność elektryczna właściwa\nZakres (10,0 – 13000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, scieki Przewodnosc elektryczna wlasciwa\nZakres (10,0 – 13000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(10,0 – 13000) μS/cm"}],"search_en":"Water, wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10,0 – 13000) μS/cm"}],"search_zh":"水、废水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、废水"},{"_id":"6a82c643884ede9a1b2c2910","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a82c643884ede9a1b2c2911","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Ścieki","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(0,0 – 50,0) ºC"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (0,0 – 50,0) ºC","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Temperatura\nZakres (0,0 – 50,0) ºC PN-77/C-04584 Scieki Temperatura\nZakres (0,0 – 50,0) ºC PN-77/C-04584","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(0,0 – 50,0) ºC"}],"search_en":"Wastewater Temperature Range PN-77/C-04584","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,0 – 50,0) ºC"}],"search_zh":"污水 温度 范围 PN-77/C-04584","test_object_zh":"污水","methodology_zh":"温度"},{"_id":"6a82c643884ede9a1b2c2912","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Gleba","methodology":"Pobieranie próbek gleby do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek gleby do badań chemicznych i fizycznych","reference":"PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","norm_bases":["PN-ISO 10381-4:2007","PN-ISO 10381-5:2009"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Pobieranie próbek gleby do badań chemicznych i fizycznych PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009 Gleba Pobieranie probek gleby do badan chemicznych i fizycznych PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Soil sampling for chemical and physical testing","search_en":"Soil Soil sampling for chemical and physical testing PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","test_object_en":"Soil","search_zh":"土壤 PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","test_object_zh":"土壤"},{"_id":"6a82c643884ede9a1b2c2913","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Osady ściekowe, Odpady o) : kod 19 08 05 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Pobieranie próbek do badań chemicznych, fizycznych, mikrobiologicznych i biologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych, mikrobiologicznych i biologicznych","reference":"PN-EN ISO 5667-13:2011 z wyłączeniem punktów 6.3.3, 6.3.4, 6.3.5, 6.3.8, 6.3.10.","norm_bases":["PN-EN ISO 5667-13:2011 z wyłączeniem punktów 6.3.3, 6.3.4, 6.3.5, 6.3.8, 6.3.10."],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe, Odpady o) : kod 19 08 05 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Pobieranie próbek do badań chemicznych, fizycznych, mikrobiologicznych i biologicznych PN-EN ISO 5667-13:2011 z wyłączeniem punktów 6.3.3, 6.3.4, 6.3.5, 6.3.8, 6.3.10. Osady sciekowe, Odpady o) : kod 19 08 05 O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Pobieranie probek do badan chemicznych, fizycznych, mikrobiologicznych i biologicznych PN-EN ISO 5667-13:2011 z wylaczeniem punktow 6.3.3, 6.3.4, 6.3.5, 6.3.8, 6.3.10.","categories":["environment","water","microbiology"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical, physical, microbiological and biological testing","search_en":"Sampling for chemical, physical, microbiological and biological testing PN-EN ISO 5667-13:2011 z wyłączeniem punktów 6.3.3, 6.3.4, 6.3.5, 6.3.8, 6.3.10.","methodology_zh":"用于化学、物理、微生物与生物检验的采样","search_zh":"用于化学、物理、微生物与生物检验的采样 PN-EN ISO 5667-13:2011 z wyłączeniem punktów 6.3.3, 6.3.4, 6.3.5, 6.3.8, 6.3.10."},{"_id":"6a82c643884ede9a1b2c2914","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Środowisko: – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"- w zakresie częstotliwości 50 Hz","range":"(1 – 30 000) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\n- w zakresie częstotliwości 50 Hz (1 – 30 000) V/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenie Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenie Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko: – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natężenie pola elektrycznego:\n- w zakresie częstotliwości 50 Hz (1 – 30 000) V/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenie Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630) Srodowisko: – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natezenie pola elektrycznego:\n- w zakresie czestotliwosci 50 Hz (1 – 30 000) V/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenie Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","search_en":"Environment: – electromagnetic field in the vicinity of electric power substations and power lines Electric field strength: Direct measurement method Załącznik do Rozporządzenie Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment: – electromagnetic field in the vicinity of electric power substations and power lines","methodology_zh":"电场强度：","search_zh":"环境：－ 变电站与输电线路周围的电磁场 电场强度： 直接测量法 Załącznik do Rozporządzenie Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境：－ 变电站与输电线路周围的电磁场"},{"_id":"6a82c643884ede9a1b2c2915","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Środowisko: – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","methodology":"Indukcja magnetyczna:","parameters":[{"name":"- w zakresie częstotliwości 50 Hz","range":"0,1 µT – 9 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna:\n- w zakresie częstotliwości 50 Hz 0,1 µT – 9 mT\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenie Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenie Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko: – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Indukcja magnetyczna:\n- w zakresie częstotliwości 50 Hz 0,1 µT – 9 mT\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenie Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630) Srodowisko: – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Indukcja magnetyczna:\n- w zakresie czestotliwosci 50 Hz 0,1 µT – 9 mT\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenie Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density:","search_en":"Environment: – electromagnetic field in the vicinity of electric power substations and power lines Magnetic flux density: Direct measurement method Załącznik do Rozporządzenie Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment: – electromagnetic field in the vicinity of electric power substations and power lines","search_zh":"环境：－ 变电站与输电线路周围的电磁场 磁感应强度： 直接测量法 Załącznik do Rozporządzenie Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","methodology_zh":"磁感应强度：","test_object_zh":"环境：－ 变电站与输电线路周围的电磁场"},{"_id":"6a82c643884ede9a1b2c2916","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Środowisko: – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","methodology":"Natężenie pola magnetycznego (z obliczeń)","parameters":[{"name":"- w zakresie częstotliwości 50 Hz"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego (z obliczeń)\n- w zakresie częstotliwości 50 Hz","reference":"Załącznik do Rozporządzenie Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenie Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko: – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natężenie pola magnetycznego (z obliczeń)\n- w zakresie częstotliwości 50 Hz Załącznik do Rozporządzenie Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630) Srodowisko: – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natezenie pola magnetycznego (z obliczen)\n- w zakresie czestotliwosci 50 Hz Zalacznik do Rozporzadzenie Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength (calculated)","search_en":"Environment: – electromagnetic field in the vicinity of electric power substations and power lines Magnetic field strength (calculated) Załącznik do Rozporządzenie Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)","test_object_en":"Environment: – electromagnetic field in the vicinity of electric power substations and power lines","search_zh":"环境：－ 变电站与输电线路周围的电磁场 Załącznik do Rozporządzenie Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)","test_object_zh":"环境：－ 变电站与输电线路周围的电磁场"},{"_id":"6a82c643884ede9a1b2c2917","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Środowisko: – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe)","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"- w zakresie częstotliwości od 10 MHz do 3 GHz","range":"(0,3 – 200) V/m"},{"name":"- w zakresie częstotliwości od 100 MHz do 60 GHz","range":"(0,5 – 200) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\n- w zakresie częstotliwości od 10 MHz do 3 GHz (0,3 – 200) V/m\n- w zakresie częstotliwości od 100 MHz do 60 GHz (0,5 – 200) V/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenie Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenie Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko: – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natężenie pola elektrycznego:\nZakres:\n- w zakresie częstotliwości od 10 MHz do 3 GHz (0,3 – 200) V/m\n- w zakresie częstotliwości od 100 MHz do 60 GHz (0,5 – 200) V/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenie Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630) Srodowisko: – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natezenie pola elektrycznego:\nZakres:\n- w zakresie czestotliwosci od 10 MHz do 3 GHz (0,3 – 200) V/m\n- w zakresie czestotliwosci od 100 MHz do 60 GHz (0,5 – 200) V/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenie Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","search_en":"Environment: – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Electric field strength: Direct measurement method Załącznik do Rozporządzenie Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment: – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements)","methodology_zh":"电场强度：","search_zh":"电场强度： 直接测量法 Załącznik do Rozporządzenie Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法"},{"_id":"6a82c643884ede9a1b2c2918","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Środowisko: – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe)","methodology":"Natężenie pola magnetycznego: (z obliczeń)","parameters":[{"name":"- w zakresie częstotliwości od 10 MHz do 60 GHz"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego: (z obliczeń)\n- w zakresie częstotliwości od 10 MHz do 60 GHz","reference":"Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko: – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natężenie pola magnetycznego: (z obliczeń)\n- w zakresie częstotliwości od 10 MHz do 60 GHz Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630) Srodowisko: – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natezenie pola magnetycznego: (z obliczen)\n- w zakresie czestotliwosci od 10 MHz do 60 GHz Punkt 3 zalacznika do Rozporzadzenia Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Environment: – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)","test_object_en":"Environment: – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements)"},{"_id":"6a82c643884ede9a1b2c2919","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Strumień objętości gazów dla ciśnień dynamicznych >10 Pa","parameters":[],"technique":"Metoda spiętrzenia","techniques":["Metoda spiętrzenia"],"computed":[],"activity":"Strumień objętości gazów dla ciśnień dynamicznych >10 Pa\nMetoda spiętrzenia","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Strumień objętości gazów dla ciśnień dynamicznych >10 Pa\nMetoda spiętrzenia PN-Z-04030-7:1994 Gazy odlotowe Strumien objetosci gazow dla cisnien dynamicznych >10 Pa\nMetoda spietrzenia PN-Z-04030-7:1994","categories":["other"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Waste gases Stagnation pressure method PN-Z-04030-7:1994","technique_en":"Stagnation pressure method","test_object_en":"Waste gases","search_zh":"废气 滞止压力法 PN-Z-04030-7:1994","test_object_zh":"废气","technique_zh":"滞止压力法"},{"_id":"6a82c643884ede9a1b2c291a","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-Z-04030-7:1994 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-Z-04030-7:1994","categories":["other"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of dust concentration","search_en":"Waste gases Sampling for determination of dust concentration PN-Z-04030-7:1994","test_object_en":"Waste gases","search_zh":"废气 粉尘浓度测定采样 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样"},{"_id":"6a82c643884ede9a1b2c291b","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"(0,001 – 100) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 Gazy odlotowe Stezenie pylu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994","categories":["other"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"(0,001 – 100) g/m3"}],"search_en":"Waste gases Dust concentration Gravimetric method Range PN-Z-04030-7:1994","technique_en":"Gravimetric method","test_object_en":"Waste gases","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,001 – 100) g/m3"}],"search_zh":"废气 粉尘浓度 重量法 范围 PN-Z-04030-7:1994","technique_zh":"重量法","test_object_zh":"废气"},{"_id":"6a82c643884ede9a1b2c291c","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja pyłu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-Z-04030-7:1994 Gazy odlotowe Emisja pylu (z obliczen) PN-Z-04030-7:1994","categories":["environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust emission (calculated)","search_en":"Waste gases Dust emission (calculated) PN-Z-04030-7:1994","test_object_en":"Waste gases","search_zh":"废气 粉尘排放量（计算值） PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a82c643884ede9a1b2c291d","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie: CO, NO, NOx,SO2, CO2","parameters":[{"name":"SO2","range":"(3 – 6000) mg/m3"},{"name":"NO","range":"(20 – 600 ) mg/m3"},{"name":"CO","range":"(2 – 2500) mg/m3"},{"name":"CO2","range":"(0,5 – 20) %"},{"name":"NO","range":"(20 – 600 ) mg/m3"},{"name":"NOx","range":"(20 – 600 ) mg/m3"},{"name":"O2","range":"(0,5 – 20,9) %"}],"technique":"Metoda absorpcji promieniowania IR; Metoda chemiluminescencyjna (CLD); Metoda paramagnetyczna (PMD)","techniques":["Metoda absorpcji promieniowania IR","Metoda chemiluminescencyjna (CLD)","Metoda paramagnetyczna (PMD)"],"computed":[],"activity":"Stężenie: CO, NO, NOx,SO2, CO2\nZakres:\nSO2 (3 – 6000) mg/m3\nNO (20 – 600 ) mg/m3\nCO (2 – 2500) mg/m3\nCO2 (0,5 – 20) %\nNO (20 – 600 ) mg/m3\nNOx (20 – 600 ) mg/m3\nO2 (0,5 – 20,9) %\nMetoda absorpcji promieniowania IR; Metoda chemiluminescencyjna (CLD); Metoda paramagnetyczna (PMD)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenie: CO, NO, NOx,SO2, CO2\nZakres:\nSO2 (3 – 6000) mg/m3\nNO (20 – 600 ) mg/m3\nCO (2 – 2500) mg/m3\nCO2 (0,5 – 20) %\nNO (20 – 600 ) mg/m3\nNOx (20 – 600 ) mg/m3\nO2 (0,5 – 20,9) %\nMetoda absorpcji promieniowania IR; Metoda chemiluminescencyjna (CLD); Metoda paramagnetyczna (PMD) PN-ISO 10396:2001 Gazy odlotowe Stezenie: CO, NO, NOx,SO2, CO2\nZakres:\nSO2 (3 – 6000) mg/m3\nNO (20 – 600 ) mg/m3\nCO (2 – 2500) mg/m3\nCO2 (0,5 – 20) %\nNO (20 – 600 ) mg/m3\nNOx (20 – 600 ) mg/m3\nO2 (0,5 – 20,9) %\nMetoda absorpcji promieniowania IR; Metoda chemiluminescencyjna (CLD); Metoda paramagnetyczna (PMD) PN-ISO 10396:2001","categories":["other"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"SO2","range":"(3 – 6000) mg/m3"},{"name":"NO","range":"(20 – 600 ) mg/m3"},{"name":"CO","range":"(2 – 2500) mg/m3"},{"name":"CO2","range":"(0,5 – 20) %"},{"name":"NO","range":"(20 – 600 ) mg/m3"},{"name":"NOx","range":"(20 – 600 ) mg/m3"},{"name":"O2","range":"(0,5 – 20,9) %"}],"search_en":"Waste gases SO2 NO CO CO2 NO NOx O2 PN-ISO 10396:2001","test_object_en":"Waste gases","search_zh":"废气 SO2 NO CO CO2 NO NOx O2 PN-ISO 10396:2001","test_object_zh":"废气","parameters_zh":[{"name":"SO2","range":"(3 – 6000) mg/m3"},{"name":"NO","range":"(20 – 600 ) mg/m3"},{"name":"CO","range":"(2 – 2500) mg/m3"},{"name":"CO2","range":"(0,5 – 20) %"},{"name":"NO","range":"(20 – 600 ) mg/m3"},{"name":"NOx","range":"(20 – 600 ) mg/m3"},{"name":"O2","range":"(0,5 – 20,9) %"}]},{"_id":"6a82c643884ede9a1b2c291e","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja CO, NO, NOx (NO i NO2 w przeliczeniu na NO2), SO2, CO2, (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja CO, NO, NOx (NO i NO2 w przeliczeniu na NO2), SO2, CO2, (z obliczeń)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja CO, NO, NOx (NO i NO2 w przeliczeniu na NO2), SO2, CO2, (z obliczeń) PN-ISO 10396:2001 Gazy odlotowe Emisja CO, NO, NOx (NO i NO2 w przeliczeniu na NO2), SO2, CO2, (z obliczen) PN-ISO 10396:2001","categories":["environment"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Waste gases PN-ISO 10396:2001","test_object_en":"Waste gases","search_zh":"废气 PN-ISO 10396:2001","test_object_zh":"废气"},{"_id":"6a82c643884ede9a1b2c291f","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych PN-EN 13649:2005 Gazy odlotowe Pobieranie probek do oznaczania stezenia indywidualnych gazowych zwiazkow organicznych PN-EN 13649:2005","categories":["other"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of the concentration of individual gaseous organic compounds","search_en":"Waste gases Sampling for determination of the concentration of individual gaseous organic compounds PN-EN 13649:2005","test_object_en":"Waste gases","search_zh":"废气 单项气态有机化合物浓度测定采样 PN-EN 13649:2005","test_object_zh":"废气","methodology_zh":"单项气态有机化合物浓度测定采样"},{"_id":"6a82c643884ede9a1b2c2920","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja indywidualnych gazowych związków organicznych (z obliczeń) PN-EN 13649:2005 Gazy odlotowe Emisja indywidualnych gazowych zwiazkow organicznych (z obliczen) PN-EN 13649:2005","categories":["environment"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of individual gaseous organic compounds (calculated)","search_en":"Waste gases Emission of individual gaseous organic compounds (calculated) PN-EN 13649:2005","test_object_en":"Waste gases","search_zh":"废气 单项气态有机化合物排放量（计算值） PN-EN 13649:2005","test_object_zh":"废气","methodology_zh":"单项气态有机化合物排放量（计算值）"},{"_id":"6a82c643884ede9a1b2c2921","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężeń związków organicznych","parameters":[],"technique":"Metoda aspiracyjna z zastosowaniem węgla aktywnego i żelu krzemionkowego","techniques":["Metoda aspiracyjna z zastosowaniem węgla aktywnego i żelu krzemionkowego"],"computed":[],"activity":"Pobieranie próbek do oznaczania stężeń związków organicznych\nMetoda aspiracyjna z zastosowaniem węgla aktywnego i żelu krzemionkowego","reference":"PN-Z-04008-4:1999","norm_bases":["PN-Z-04008-4:1999"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężeń związków organicznych\nMetoda aspiracyjna z zastosowaniem węgla aktywnego i żelu krzemionkowego PN-Z-04008-4:1999 Gazy odlotowe Pobieranie probek do oznaczania stezen zwiazkow organicznych\nMetoda aspiracyjna z zastosowaniem wegla aktywnego i zelu krzemionkowego PN-Z-04008-4:1999","categories":["other"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of concentrations of organic compounds","search_en":"Waste gases Sampling for determination of concentrations of organic compounds Aspiration method using activated carbon and silica gel PN-Z-04008-4:1999","technique_en":"Aspiration method using activated carbon and silica gel","test_object_en":"Waste gases","search_zh":"废气 有机化合物浓度测定采样 PN-Z-04008-4:1999","test_object_zh":"废气","methodology_zh":"有机化合物浓度测定采样"},{"_id":"6a82c643884ede9a1b2c2922","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja związków organicznych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja związków organicznych (z obliczeń)","reference":"PN-Z-04008-4:1999","norm_bases":["PN-Z-04008-4:1999"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja związków organicznych (z obliczeń) PN-Z-04008-4:1999 Gazy odlotowe Emisja zwiazkow organicznych (z obliczen) PN-Z-04008-4:1999","categories":["environment"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of organic compounds (calculated)","search_en":"Waste gases Emission of organic compounds (calculated) PN-Z-04008-4:1999","test_object_en":"Waste gases","search_zh":"废气 有机化合物排放量（计算值） PN-Z-04008-4:1999","test_object_zh":"废气","methodology_zh":"有机化合物排放量（计算值）"},{"_id":"6a82c643884ede9a1b2c2923","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Woda","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,5 –100) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,5 –100) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Pracownia w Lublinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Indeks nadmanganianowy\nZakres (0,5 –100) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda Indeks nadmanganianowy\nZakres (0,5 –100) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,5 –100) mg/l O2"}],"search_en":"Water Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,5 –100) mg/l O2"}],"search_zh":"水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a82c643884ede9a1b2c2924","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Woda","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) (z obliczeń)","reference":"PB-27/CLB wydanie 2 z 04.05.2026 r.","norm_bases":["PB-27/CLB wydanie 2 z 04.05.2026 r."],"lab_section":"Pracownia w Lublinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Sumaryczna zawartość wapnia i magnezu (twardość ogólna) (z obliczeń) PB-27/CLB wydanie 2 z 04.05.2026 r. Woda Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna) (z obliczen) PB-27/CLB wydanie 2 z 04.05.2026 r.","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total calcium and magnesium content (total hardness) (calculated)","search_en":"Water Total calcium and magnesium content (total hardness) (calculated) PB-27/CLB wydanie 2 z 04.05.2026 r.","test_object_en":"Water","search_zh":"水 钙与镁总含量（总硬度）（由计算得出） PB-27/CLB wydanie 2 z 04.05.2026 r.","test_object_zh":"水","methodology_zh":"钙与镁总含量（总硬度）（由计算得出）"},{"_id":"6a82c643884ede9a1b2c2925","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie anionów:","parameters":[{"name":"Fluorki","range":"(0,01 – 10) mg/l"},{"name":"Chlorki","range":"(0,1 – 1000) mg/l"},{"name":"Bromki","range":"(0,05 – 20) mg/l"},{"name":"Azot azotanowy","range":"(0,02 – 11,3) mg/l"},{"name":"Siarczany","range":"(0,1 – 100) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów:\nZakres:\nFluorki (0,01 – 10) mg/l\nChlorki (0,1 – 1000) mg/l\nBromki (0,05 – 20) mg/l\nAzot azotanowy (0,02 – 11,3) mg/l\nSiarczany (0,1 – 100) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009 +AC:2012","norm_bases":["PN-EN ISO 10304-1:2009 +AC:2012"],"lab_section":"Pracownia w Lublinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie anionów:\nZakres:\nFluorki (0,01 – 10) mg/l\nChlorki (0,1 – 1000) mg/l\nBromki (0,05 – 20) mg/l\nAzot azotanowy (0,02 – 11,3) mg/l\nSiarczany (0,1 – 100) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 +AC:2012 Woda Stezenie anionow:\nZakres:\nFluorki (0,01 – 10) mg/l\nChlorki (0,1 – 1000) mg/l\nBromki (0,05 – 20) mg/l\nAzot azotanowy (0,02 – 11,3) mg/l\nSiarczany (0,1 – 100) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009 +AC:2012","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations:","parameters_en":[{"name":"Fluorides","range":"(0,01 – 10) mg/l"},{"name":"Chlorides","range":"(0,1 – 1000) mg/l"},{"name":"Bromides","range":"(0,05 – 20) mg/l"},{"name":"Nitrate nitrogen","range":"(0,02 – 11,3) mg/l"},{"name":"Sulfates","range":"(0,1 – 100) mg/l"}],"search_en":"Water Anion concentrations: Ion chromatography with conductometric detection (IC-CD) Fluorides Chlorides Bromides Nitrate nitrogen Sulfates PN-EN ISO 10304-1:2009 +AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water","methodology_zh":"阴离子浓度：","parameters_zh":[{"name":"氟化物","range":"(0,01 – 10) mg/l"},{"name":"氯化物","range":"(0,1 – 1000) mg/l"},{"name":"Bromki","range":"(0,05 – 20) mg/l"},{"name":"硝酸盐氮","range":"(0,02 – 11,3) mg/l"},{"name":"硫酸盐","range":"(0,1 – 100) mg/l"}],"search_zh":"水 阴离子浓度： 离子色谱-电导检测法（IC-CD） 氟化物 氯化物 硝酸盐氮 硫酸盐 PN-EN ISO 10304-1:2009 +AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水"},{"_id":"6a82c643884ede9a1b2c2926","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Woda","methodology":"Azotany (z obliczeń)","parameters":[{"name":"Azotany","range":"(0,09 – 50) mg/l"}],"technique":null,"techniques":[],"computed":[],"activity":"Azotany (z obliczeń)\nAzotany (0,09 – 50) mg/l","reference":"PN-EN ISO 10304-1:2009 +AC:2012","norm_bases":["PN-EN ISO 10304-1:2009 +AC:2012"],"lab_section":"Pracownia w Lublinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Azotany (z obliczeń)\nAzotany (0,09 – 50) mg/l PN-EN ISO 10304-1:2009 +AC:2012 Woda Azotany (z obliczen)\nAzotany (0,09 – 50) mg/l PN-EN ISO 10304-1:2009 +AC:2012","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Nitrates","range":"(0,09 – 50) mg/l"}],"search_en":"Water Nitrates PN-EN ISO 10304-1:2009 +AC:2012","test_object_en":"Water","parameters_zh":[{"name":"硝酸盐","range":"(0,09 – 50) mg/l"}],"search_zh":"水 硝酸盐 PN-EN ISO 10304-1:2009 +AC:2012","test_object_zh":"水"},{"_id":"6a82c643884ede9a1b2c2927","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Woda","methodology":"Indeks oleju mineralnego","parameters":[{"name":"Zakres","range":"(0,06 – 150) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Indeks oleju mineralnego\nZakres (0,06 – 150) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":"Pracownia w Lublinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Indeks oleju mineralnego\nZakres (0,06 – 150) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda Indeks oleju mineralnego\nZakres (0,06 – 150) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil index","parameters_en":[{"name":"Range","range":"(0,06 – 150) mg/l"}],"search_en":"Water Mineral oil index Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,06 – 150) mg/l"}],"search_zh":"水 矿物油指数 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"水","methodology_zh":"矿物油指数"},{"_id":"6a82c643884ede9a1b2c2928","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Woda","methodology":"Chemiczne zapotrzebowanie tlenu ChZT-Cr","parameters":[{"name":"Zakres","range":"(10 – 150) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (10 – 150) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia w Lublinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (10 – 150) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (10 – 150) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand COD-Cr","parameters_en":[{"name":"Range","range":"(10 – 150) mg/l O2"}],"search_en":"Water Chemical oxygen demand COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(10 – 150) mg/l O2"}],"search_zh":"水 化学需氧量 COD-Cr 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"化学需氧量 COD-Cr"},{"_id":"6a82c643884ede9a1b2c2929","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie lotnych związków organicznych","parameters":[{"name":"Benzen","range":"(0,010 – 150) µg/l"},{"name":"Naftalen","range":"(0,010 – 150) µg/l"},{"name":"1,2-dichloroetan","range":"(0,050 – 150) µg/l"},{"name":"Dichlorometan","range":"(0,050 – 150) µg/l"},{"name":"Heksachlorobutadien","range":"(0,010 – 150) µg/l"},{"name":"Trichlorometan","range":"(0,050 – 150) µg/l"},{"name":"Tetrachlorometan","range":"(0,050 – 150) µg/l"},{"name":"Trichloroetylen","range":"(0,050 – 150) µg/l"},{"name":"Tetrachloroetylen","range":"(0,050 – 150) µg/l"},{"name":"1,2,3-trichlorobenzen","range":"(0,003 – 150) µg/l"},{"name":"1,2,4-trichlorobenzen","range":"(0,003 – 150) µg/l"},{"name":"1,3,5-trichlorobenzen","range":"(0,004 – 150) µg/l"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Stężenie lotnych związków organicznych\nZakres:\nBenzen (0,010 – 150) µg/l\nNaftalen (0,010 – 150) µg/l\n1,2-dichloroetan (0,050 – 150) µg/l\nDichlorometan (0,050 – 150) µg/l\nHeksachlorobutadien (0,010 – 150) µg/l\nTrichlorometan (0,050 – 150) µg/l\nTetrachlorometan (0,050 – 150) µg/l\nTrichloroetylen (0,050 – 150) µg/l\nTetrachloroetylen (0,050 – 150) µg/l\n1,2,3-trichlorobenzen (0,003 – 150) µg/l\n1,2,4-trichlorobenzen (0,003 – 150) µg/l\n1,3,5-trichlorobenzen (0,004 – 150) µg/l\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PN-EN ISO 15680:2008","norm_bases":["PN-EN ISO 15680:2008"],"lab_section":"Pracownia w Lublinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie lotnych związków organicznych\nZakres:\nBenzen (0,010 – 150) µg/l\nNaftalen (0,010 – 150) µg/l\n1,2-dichloroetan (0,050 – 150) µg/l\nDichlorometan (0,050 – 150) µg/l\nHeksachlorobutadien (0,010 – 150) µg/l\nTrichlorometan (0,050 – 150) µg/l\nTetrachlorometan (0,050 – 150) µg/l\nTrichloroetylen (0,050 – 150) µg/l\nTetrachloroetylen (0,050 – 150) µg/l\n1,2,3-trichlorobenzen (0,003 – 150) µg/l\n1,2,4-trichlorobenzen (0,003 – 150) µg/l\n1,3,5-trichlorobenzen (0,004 – 150) µg/l\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PN-EN ISO 15680:2008 Woda Stezenie lotnych zwiazkow organicznych\nZakres:\nBenzen (0,010 – 150) µg/l\nNaftalen (0,010 – 150) µg/l\n1,2-dichloroetan (0,050 – 150) µg/l\nDichlorometan (0,050 – 150) µg/l\nHeksachlorobutadien (0,010 – 150) µg/l\nTrichlorometan (0,050 – 150) µg/l\nTetrachlorometan (0,050 – 150) µg/l\nTrichloroetylen (0,050 – 150) µg/l\nTetrachloroetylen (0,050 – 150) µg/l\n1,2,3-trichlorobenzen (0,003 – 150) µg/l\n1,2,4-trichlorobenzen (0,003 – 150) µg/l\n1,3,5-trichlorobenzen (0,004 – 150) µg/l\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PN-EN ISO 15680:2008","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of volatile organic compounds","parameters_en":[{"name":"Benzene","range":"(0,010 – 150) µg/l"},{"name":"Naphthalene","range":"(0,010 – 150) µg/l"},{"name":"1,2-dichloroethane","range":"(0,050 – 150) µg/l"},{"name":"Dichloromethane","range":"(0,050 – 150) µg/l"},{"name":"Hexachlorobutadiene","range":"(0,010 – 150) µg/l"},{"name":"Trichloromethane","range":"(0,050 – 150) µg/l"},{"name":"Tetrachloromethane","range":"(0,050 – 150) µg/l"},{"name":"Trichloroethylene","range":"(0,050 – 150) µg/l"},{"name":"Tetrachloroethylene","range":"(0,050 – 150) µg/l"},{"name":"1,2,3-trichlorobenzene","range":"(0,003 – 150) µg/l"},{"name":"1,2,4-trichlorobenzene","range":"(0,003 – 150) µg/l"},{"name":"1,3,5-trichlorobenzene","range":"(0,004 – 150) µg/l"}],"search_en":"Water Concentration of volatile organic compounds Gas chromatography with mass spectrometry detection (GC-MS) Benzene Naphthalene 1,2-dichloroethane Dichloromethane Hexachlorobutadiene Trichloromethane Tetrachloromethane Trichloroethylene Tetrachloroethylene 1,2,3-trichlorobenzene 1,2,4-trichlorobenzene 1,3,5-trichlorobenzene PN-EN ISO 15680:2008","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Water","search_zh":"水 挥发性有机物浓度 气相色谱-质谱法（GC-MS） 苯 萘 1,2-二氯乙烷 二氯甲烷 六氯丁二烯 三氯甲烷 四氯化碳 1,2,3-三氯苯 1,2,4-三氯苯 1,3,5-三氯苯 PN-EN ISO 15680:2008","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"水","methodology_zh":"挥发性有机物浓度","parameters_zh":[{"name":"苯","range":"(0,010 – 150) µg/l"},{"name":"萘","range":"(0,010 – 150) µg/l"},{"name":"1,2-二氯乙烷","range":"(0,050 – 150) µg/l"},{"name":"二氯甲烷","range":"(0,050 – 150) µg/l"},{"name":"六氯丁二烯","range":"(0,010 – 150) µg/l"},{"name":"三氯甲烷","range":"(0,050 – 150) µg/l"},{"name":"四氯化碳","range":"(0,050 – 150) µg/l"},{"name":"Trichloroetylen","range":"(0,050 – 150) µg/l"},{"name":"Tetrachloroetylen","range":"(0,050 – 150) µg/l"},{"name":"1,2,3-三氯苯","range":"(0,003 – 150) µg/l"},{"name":"1,2,4-三氯苯","range":"(0,003 – 150) µg/l"},{"name":"1,3,5-三氯苯","range":"(0,004 – 150) µg/l"}]},{"_id":"6a82c643884ede9a1b2c292a","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie trichlorobenzenów (suma 1,2,3-trichlorobenzen 1,2,4-trichlorobenzen 1,3,5-trichlorobenzen (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie trichlorobenzenów (suma 1,2,3-trichlorobenzen 1,2,4-trichlorobenzen 1,3,5-trichlorobenzen (z obliczeń)","reference":"PN-EN ISO 15680:2008","norm_bases":["PN-EN ISO 15680:2008"],"lab_section":"Pracownia w Lublinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie trichlorobenzenów (suma 1,2,3-trichlorobenzen 1,2,4-trichlorobenzen 1,3,5-trichlorobenzen (z obliczeń) PN-EN ISO 15680:2008 Woda Stezenie trichlorobenzenow (suma 1,2,3-trichlorobenzen 1,2,4-trichlorobenzen 1,3,5-trichlorobenzen (z obliczen) PN-EN ISO 15680:2008","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water PN-EN ISO 15680:2008","test_object_en":"Water","search_zh":"水 PN-EN ISO 15680:2008","test_object_zh":"水"},{"_id":"6a82c643884ede9a1b2c292b","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie substancji priorytetowych","parameters":[{"name":"Aklonifen","range":"(0,02 – 0,120) µg/l"},{"name":"Alachlor","range":"(0,001 – 17,00) µg/l"},{"name":"Aldryna","range":"(0,0005 – 2,40) µg/l"},{"name":"Dieldryna","range":"(0,0005 – 0,90) µg/l"},{"name":"Endryna","range":"(0,001 – 1,30) µg/l"},{"name":"Izodryna","range":"(0,0005 – 0,120) µg/l"},{"name":"alfa-Endosulfan","range":"(0,00075 – 0,120) µg/l"},{"name":"beta-Endosulfan","range":"(0,0005 – 0,120) µg/l"},{"name":"alfa-Heksachlorocykloheksan (alfa-HCH)","range":"(0,001 – 0,120) µg/l"},{"name":"beta-Heksachlorocykloheksan (beta-HCH)","range":"(0,001 – 1,70) µg/l"},{"name":"delta-Heksachlorocykloheksan (delta-HCH)","range":"(0,001 – 0,120) µg/l"},{"name":"gamma-Heksachlorocykloheksan (gamma-HCH)","range":"(0,001 – 0,120) µg/l"},{"name":"o,p’-DDT","range":"(0,001 – 0,120) µg/l"},{"name":"p,p‘-DDD","range":"(0,001 – 0,120) µg/l"},{"name":"p,p‘-DDE","range":"(0,001 – 0,120) µg/l"},{"name":"p,p’-DDT","range":"(0,001 – 0,120) µg/l"},{"name":"Chinoksyfen","range":"(0,001 – 0,120) µg/l"},{"name":"Chlorfenwinfos","range":"(0,001 – 0,120) µg/l"},{"name":"Chlorpyrifos","range":"(0,001 – 0,120) µg/l"},{"name":"Cybutryna","range":"(0,0005 – 0,120) µg/l"},{"name":"Dichlorfos","range":"(0,00018 – 0,120) µg/l"},{"name":"Atrazyna","range":"(0,001 – 3,60) µg/l"},{"name":"Symazyna","range":"(0,001 – 1,00) µg/l"},{"name":"Terbutryna","range":"(0,001 – 0,120) µg/l"},{"name":"Trifluralina","range":"(0,001 – 0,120) µg/l"},{"name":"Heksachlorobenzen","range":"(0,001 – 4,70) µg/l"},{"name":"Pentachlorobenzen","range":"(0,001 – 0,120) µg/l"},{"name":"Bifenoks","range":"(0,003 – 0,120) µg/l"}],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)"],"computed":[],"activity":"Stężenie substancji priorytetowych\nZakres:\nAklonifen (0,02 – 0,120) µg/l\nAlachlor (0,001 – 17,00) µg/l\nAldryna (0,0005 – 2,40) µg/l\nDieldryna (0,0005 – 0,90) µg/l\nEndryna (0,001 – 1,30) µg/l\nIzodryna (0,0005 – 0,120) µg/l\nalfa-Endosulfan (0,00075 – 0,120) µg/l\nbeta-Endosulfan (0,0005 – 0,120) µg/l\nalfa-Heksachlorocykloheksan (alfa-HCH) (0,001 – 0,120) µg/l\nbeta-Heksachlorocykloheksan (beta-HCH) (0,001 – 1,70) µg/l\ndelta-Heksachlorocykloheksan (delta-HCH) (0,001 – 0,120) µg/l\ngamma-Heksachlorocykloheksan (gamma-HCH) (0,001 – 0,120) µg/l\no,p’-DDT (0,001 – 0,120) µg/l\np,p‘-DDD (0,001 – 0,120) µg/l\np,p‘-DDE (0,001 – 0,120) µg/l\np,p’-DDT (0,001 – 0,120) µg/l\nChinoksyfen (0,001 – 0,120) µg/l\nChlorfenwinfos (0,001 – 0,120) µg/l\nChlorpyrifos (0,001 – 0,120) µg/l\nCybutryna (0,0005 – 0,120) µg/l\nDichlorfos (0,00018 – 0,120) µg/l\nAtrazyna (0,001 – 3,60) µg/l\nSymazyna (0,001 – 1,00) µg/l\nTerbutryna (0,001 – 0,120) µg/l\nTrifluralina (0,001 – 0,120) µg/l\nHeksachlorobenzen (0,001 – 4,70) µg/l\nPentachlorobenzen (0,001 – 0,120) µg/l\nBifenoks (0,003 – 0,120) µg/l\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","reference":"PB-03/CLB wydanie 1 z dnia 03.01.2022","norm_bases":["PB-03/CLB wydanie 1 z dnia 03.01.2022"],"lab_section":"Pracownia w Lublinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie substancji priorytetowych\nZakres:\nAklonifen (0,02 – 0,120) µg/l\nAlachlor (0,001 – 17,00) µg/l\nAldryna (0,0005 – 2,40) µg/l\nDieldryna (0,0005 – 0,90) µg/l\nEndryna (0,001 – 1,30) µg/l\nIzodryna (0,0005 – 0,120) µg/l\nalfa-Endosulfan (0,00075 – 0,120) µg/l\nbeta-Endosulfan (0,0005 – 0,120) µg/l\nalfa-Heksachlorocykloheksan (alfa-HCH) (0,001 – 0,120) µg/l\nbeta-Heksachlorocykloheksan (beta-HCH) (0,001 – 1,70) µg/l\ndelta-Heksachlorocykloheksan (delta-HCH) (0,001 – 0,120) µg/l\ngamma-Heksachlorocykloheksan (gamma-HCH) (0,001 – 0,120) µg/l\no,p’-DDT (0,001 – 0,120) µg/l\np,p‘-DDD (0,001 – 0,120) µg/l\np,p‘-DDE (0,001 – 0,120) µg/l\np,p’-DDT (0,001 – 0,120) µg/l\nChinoksyfen (0,001 – 0,120) µg/l\nChlorfenwinfos (0,001 – 0,120) µg/l\nChlorpyrifos (0,001 – 0,120) µg/l\nCybutryna (0,0005 – 0,120) µg/l\nDichlorfos (0,00018 – 0,120) µg/l\nAtrazyna (0,001 – 3,60) µg/l\nSymazyna (0,001 – 1,00) µg/l\nTerbutryna (0,001 – 0,120) µg/l\nTrifluralina (0,001 – 0,120) µg/l\nHeksachlorobenzen (0,001 – 4,70) µg/l\nPentachlorobenzen (0,001 – 0,120) µg/l\nBifenoks (0,003 – 0,120) µg/l\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS) PB-03/CLB wydanie 1 z dnia 03.01.2022 Woda Stezenie substancji priorytetowych\nZakres:\nAklonifen (0,02 – 0,120) µg/l\nAlachlor (0,001 – 17,00) µg/l\nAldryna (0,0005 – 2,40) µg/l\nDieldryna (0,0005 – 0,90) µg/l\nEndryna (0,001 – 1,30) µg/l\nIzodryna (0,0005 – 0,120) µg/l\nalfa-Endosulfan (0,00075 – 0,120) µg/l\nbeta-Endosulfan (0,0005 – 0,120) µg/l\nalfa-Heksachlorocykloheksan (alfa-HCH) (0,001 – 0,120) µg/l\nbeta-Heksachlorocykloheksan (beta-HCH) (0,001 – 1,70) µg/l\ndelta-Heksachlorocykloheksan (delta-HCH) (0,001 – 0,120) µg/l\ngamma-Heksachlorocykloheksan (gamma-HCH) (0,001 – 0,120) µg/l\no,p’-DDT (0,001 – 0,120) µg/l\np,p‘-DDD (0,001 – 0,120) µg/l\np,p‘-DDE (0,001 – 0,120) µg/l\np,p’-DDT (0,001 – 0,120) µg/l\nChinoksyfen (0,001 – 0,120) µg/l\nChlorfenwinfos (0,001 – 0,120) µg/l\nChlorpyrifos (0,001 – 0,120) µg/l\nCybutryna (0,0005 – 0,120) µg/l\nDichlorfos (0,00018 – 0,120) µg/l\nAtrazyna (0,001 – 3,60) µg/l\nSymazyna (0,001 – 1,00) µg/l\nTerbutryna (0,001 – 0,120) µg/l\nTrifluralina (0,001 – 0,120) µg/l\nHeksachlorobenzen (0,001 – 4,70) µg/l\nPentachlorobenzen (0,001 – 0,120) µg/l\nBifenoks (0,003 – 0,120) µg/l\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC-MS-MS) PB-03/CLB wydanie 1 z dnia 03.01.2022","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Aclonifen","range":"(0,02 – 0,120) µg/l"},{"name":"Alachlor","range":"(0,001 – 17,00) µg/l"},{"name":"Aldrin","range":"(0,0005 – 2,40) µg/l"},{"name":"Dieldrin","range":"(0,0005 – 0,90) µg/l"},{"name":"Endrin","range":"(0,001 – 1,30) µg/l"},{"name":"Isodrin","range":"(0,0005 – 0,120) µg/l"},{"name":"alfa-Endosulfan","range":"(0,00075 – 0,120) µg/l"},{"name":"beta-Endosulfan","range":"(0,0005 – 0,120) µg/l"},{"name":"alfa-Heksachlorocykloheksan (alfa-HCH)","range":"(0,001 – 0,120) µg/l"},{"name":"beta-Heksachlorocykloheksan (beta-HCH)","range":"(0,001 – 1,70) µg/l"},{"name":"delta-Heksachlorocykloheksan (delta-HCH)","range":"(0,001 – 0,120) µg/l"},{"name":"gamma-Heksachlorocykloheksan (gamma-HCH)","range":"(0,001 – 0,120) µg/l"},{"name":"o,p’-DDT","range":"(0,001 – 0,120) µg/l"},{"name":"p,p‘-DDD","range":"(0,001 – 0,120) µg/l"},{"name":"p,p‘-DDE","range":"(0,001 – 0,120) µg/l"},{"name":"p,p’-DDT","range":"(0,001 – 0,120) µg/l"},{"name":"Quinoxyfen","range":"(0,001 – 0,120) µg/l"},{"name":"Chlorfenvinphos","range":"(0,001 – 0,120) µg/l"},{"name":"Chlorpyrifos","range":"(0,001 – 0,120) µg/l"},{"name":"Cybutryna","range":"(0,0005 – 0,120) µg/l"},{"name":"Dichlorvos","range":"(0,00018 – 0,120) µg/l"},{"name":"Atrazine","range":"(0,001 – 3,60) µg/l"},{"name":"Simazine","range":"(0,001 – 1,00) µg/l"},{"name":"Terbutryn","range":"(0,001 – 0,120) µg/l"},{"name":"Trifluralin","range":"(0,001 – 0,120) µg/l"},{"name":"Hexachlorobenzene","range":"(0,001 – 4,70) µg/l"},{"name":"Pentachlorobenzene","range":"(0,001 – 0,120) µg/l"},{"name":"Bifenox","range":"(0,003 – 0,120) µg/l"}],"search_en":"Water Gas chromatography with tandem mass spectrometry detection (GC-MS-MS) Aclonifen Alachlor Aldrin Dieldrin Endrin Isodrin beta-Endosulfan o,p’-DDT p,p’-DDT Quinoxyfen Chlorfenvinphos Dichlorvos Atrazine Simazine Terbutryn Trifluralin Hexachlorobenzene Pentachlorobenzene Bifenox PB-03/CLB wydanie 1 z dnia 03.01.2022","technique_en":"Gas chromatography with tandem mass spectrometry detection (GC-MS-MS)","test_object_en":"Water","search_zh":"水 气相色谱-串联质谱法（GC-MS-MS） 艾氏剂 狄氏剂 异狄氏剂 异艾氏剂 p,p'-滴滴涕（DDT） 莠去津 六氯苯 五氯苯 PB-03/CLB wydanie 1 z dnia 03.01.2022","test_object_zh":"水","technique_zh":"气相色谱-串联质谱法（GC-MS-MS）","parameters_zh":[{"name":"Aklonifen","range":"(0,02 – 0,120) µg/l"},{"name":"Alachlor","range":"(0,001 – 17,00) µg/l"},{"name":"艾氏剂","range":"(0,0005 – 2,40) µg/l"},{"name":"狄氏剂","range":"(0,0005 – 0,90) µg/l"},{"name":"异狄氏剂","range":"(0,001 – 1,30) µg/l"},{"name":"异艾氏剂","range":"(0,0005 – 0,120) µg/l"},{"name":"alfa-Endosulfan","range":"(0,00075 – 0,120) µg/l"},{"name":"beta-Endosulfan","range":"(0,0005 – 0,120) µg/l"},{"name":"alfa-Heksachlorocykloheksan (alfa-HCH)","range":"(0,001 – 0,120) µg/l"},{"name":"beta-Heksachlorocykloheksan (beta-HCH)","range":"(0,001 – 1,70) µg/l"},{"name":"delta-Heksachlorocykloheksan (delta-HCH)","range":"(0,001 – 0,120) µg/l"},{"name":"gamma-Heksachlorocykloheksan (gamma-HCH)","range":"(0,001 – 0,120) µg/l"},{"name":"o,p’-DDT","range":"(0,001 – 0,120) µg/l"},{"name":"p,p‘-DDD","range":"(0,001 – 0,120) µg/l"},{"name":"p,p‘-DDE","range":"(0,001 – 0,120) µg/l"},{"name":"p,p'-滴滴涕（DDT）","range":"(0,001 – 0,120) µg/l"},{"name":"Chinoksyfen","range":"(0,001 – 0,120) µg/l"},{"name":"Chlorfenwinfos","range":"(0,001 – 0,120) µg/l"},{"name":"Chlorpyrifos","range":"(0,001 – 0,120) µg/l"},{"name":"Cybutryna","range":"(0,0005 – 0,120) µg/l"},{"name":"Dichlorfos","range":"(0,00018 – 0,120) µg/l"},{"name":"莠去津","range":"(0,001 – 3,60) µg/l"},{"name":"Symazyna","range":"(0,001 – 1,00) µg/l"},{"name":"Terbutryna","range":"(0,001 – 0,120) µg/l"},{"name":"Trifluralina","range":"(0,001 – 0,120) µg/l"},{"name":"六氯苯","range":"(0,001 – 4,70) µg/l"},{"name":"五氯苯","range":"(0,001 – 0,120) µg/l"},{"name":"Bifenoks","range":"(0,003 – 0,120) µg/l"}]},{"_id":"6a82c643884ede9a1b2c292c","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie heksachlorocykloheksanu (HCH) (suma izomerów alfa-HCH, beta-HCH, delta-HCH, gamma-HCH) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie heksachlorocykloheksanu (HCH) (suma izomerów alfa-HCH, beta-HCH, delta-HCH, gamma-HCH) (z obliczeń)","reference":"PB-03/CLB wydanie 1 z dnia 03.01.2022","norm_bases":["PB-03/CLB wydanie 1 z dnia 03.01.2022"],"lab_section":"Pracownia w Lublinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie heksachlorocykloheksanu (HCH) (suma izomerów alfa-HCH, beta-HCH, delta-HCH, gamma-HCH) (z obliczeń) PB-03/CLB wydanie 1 z dnia 03.01.2022 Woda Stezenie heksachlorocykloheksanu (HCH) (suma izomerow alfa-HCH, beta-HCH, delta-HCH, gamma-HCH) (z obliczen) PB-03/CLB wydanie 1 z dnia 03.01.2022","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water PB-03/CLB wydanie 1 z dnia 03.01.2022","test_object_en":"Water","search_zh":"水 PB-03/CLB wydanie 1 z dnia 03.01.2022","test_object_zh":"水"},{"_id":"6a82c643884ede9a1b2c292d","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie DDT całkowitego ( suma o,p’-DDT, p,p‘-DDD, p,p‘-DDE, p,p’-DDT) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie DDT całkowitego ( suma o,p’-DDT, p,p‘-DDD, p,p‘-DDE, p,p’-DDT) (z obliczeń)","reference":"PB-03/CLB wydanie 1 z dnia 03.01.2022","norm_bases":["PB-03/CLB wydanie 1 z dnia 03.01.2022"],"lab_section":"Pracownia w Lublinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie DDT całkowitego ( suma o,p’-DDT, p,p‘-DDD, p,p‘-DDE, p,p’-DDT) (z obliczeń) PB-03/CLB wydanie 1 z dnia 03.01.2022 Woda Stezenie DDT calkowitego ( suma o,p’-DDT, p,p‘-DDD, p,p‘-DDE, p,p’-DDT) (z obliczen) PB-03/CLB wydanie 1 z dnia 03.01.2022","categories":["water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water PB-03/CLB wydanie 1 z dnia 03.01.2022","test_object_en":"Water","search_zh":"水 PB-03/CLB wydanie 1 z dnia 03.01.2022","test_object_zh":"水"},{"_id":"6a82c643884ede9a1b2c292e","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie Endosulfanu (suma izomerów alfa-Endosulfan, beta-Endosulfan) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie Endosulfanu (suma izomerów alfa-Endosulfan, beta-Endosulfan) (z obliczeń)","reference":"PB-03/CLB wydanie 1 z dnia 03.01.2022","norm_bases":["PB-03/CLB wydanie 1 z dnia 03.01.2022"],"lab_section":"Pracownia w Lublinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie Endosulfanu (suma izomerów alfa-Endosulfan, beta-Endosulfan) (z obliczeń) PB-03/CLB wydanie 1 z dnia 03.01.2022 Woda Stezenie Endosulfanu (suma izomerow alfa-Endosulfan, beta-Endosulfan) (z obliczen) PB-03/CLB wydanie 1 z dnia 03.01.2022","categories":["water"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water PB-03/CLB wydanie 1 z dnia 03.01.2022","test_object_en":"Water","search_zh":"水 PB-03/CLB wydanie 1 z dnia 03.01.2022","test_object_zh":"水"},{"_id":"6a82c643884ede9a1b2c292f","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie metali:","parameters":[{"name":"Glin","range":"(5,00 – 1000) µg/l"},{"name":"Arsen","range":"(1,00 – 100) µg/l"},{"name":"Bor","range":"(10,0 – 1000) µg/l"},{"name":"Bar","range":"(0,500 – 1000) µg/l"},{"name":"Kadm","range":"(0,020 – 100) µg/l"},{"name":"Chrom ogólny","range":"(0,200 – 100) µg/l"},{"name":"Miedź","range":"(1,00 – 1000) µg/l"},{"name":"Żelazo ogólne","range":"(5,00 – 1000) µg/l"},{"name":"Mangan","range":"(1,00 – 100) µg/l"},{"name":"Molibden","range":"(0,500 – 100) µg/l"},{"name":"Nikiel","range":"(1,00 – 100) µg/l"},{"name":"Ołów","range":"(0,200 – 100) µg/l"},{"name":"Cynk","range":"(2,00 – 1000) µg/l"},{"name":"Kobalt","range":"(0,200 – 100) µg/l"},{"name":"Srebro","range":"(0,200 – 100) µg/l"},{"name":"Wanad","range":"(1,00 – 100) µg/l"},{"name":"Beryl","range":"(0,100 – 100) µg/l"},{"name":"Stront","range":"(0,200 – 100) µg/l"},{"name":"Antymon","range":"(0,500 – 100) µg/l"},{"name":"Selen","range":"(1,00 – 100) µg/l"},{"name":"Cyna","range":"(1,00 – 100) µg/l"},{"name":"Tytan","range":"(1,00 – 100) µg/l"},{"name":"Tal","range":"(0,100 – 100) µg/l"},{"name":"Uran","range":"(0,100 – 100) µg/l"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Stężenie metali:\nZakres:\nGlin (5,00 – 1000) µg/l\nArsen (1,00 – 100) µg/l\nBor (10,0 – 1000) µg/l\nBar (0,500 – 1000) µg/l\nKadm (0,020 – 100) µg/l\nChrom ogólny (0,200 – 100) µg/l\nMiedź (1,00 – 1000) µg/l\nŻelazo ogólne (5,00 – 1000) µg/l\nMangan (1,00 – 100) µg/l\nMolibden (0,500 – 100) µg/l\nNikiel (1,00 – 100) µg/l\nOłów (0,200 – 100) µg/l\nCynk (2,00 – 1000) µg/l\nKobalt (0,200 – 100) µg/l\nSrebro (0,200 – 100) µg/l\nWanad (1,00 – 100) µg/l\nBeryl (0,100 – 100) µg/l\nStront (0,200 – 100) µg/l\nAntymon (0,500 – 100) µg/l\nSelen (1,00 – 100) µg/l\nCyna (1,00 – 100) µg/l\nTytan (1,00 – 100) µg/l\nTal (0,100 – 100) µg/l\nUran (0,100 – 100) µg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN ISO 17294-2:2024-04"],"lab_section":"Pracownia w Lublinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie metali:\nZakres:\nGlin (5,00 – 1000) µg/l\nArsen (1,00 – 100) µg/l\nBor (10,0 – 1000) µg/l\nBar (0,500 – 1000) µg/l\nKadm (0,020 – 100) µg/l\nChrom ogólny (0,200 – 100) µg/l\nMiedź (1,00 – 1000) µg/l\nŻelazo ogólne (5,00 – 1000) µg/l\nMangan (1,00 – 100) µg/l\nMolibden (0,500 – 100) µg/l\nNikiel (1,00 – 100) µg/l\nOłów (0,200 – 100) µg/l\nCynk (2,00 – 1000) µg/l\nKobalt (0,200 – 100) µg/l\nSrebro (0,200 – 100) µg/l\nWanad (1,00 – 100) µg/l\nBeryl (0,100 – 100) µg/l\nStront (0,200 – 100) µg/l\nAntymon (0,500 – 100) µg/l\nSelen (1,00 – 100) µg/l\nCyna (1,00 – 100) µg/l\nTytan (1,00 – 100) µg/l\nTal (0,100 – 100) µg/l\nUran (0,100 – 100) µg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN ISO 17294-2:2024-04 Woda Stezenie metali:\nZakres:\nGlin (5,00 – 1000) µg/l\nArsen (1,00 – 100) µg/l\nBor (10,0 – 1000) µg/l\nBar (0,500 – 1000) µg/l\nKadm (0,020 – 100) µg/l\nChrom ogolny (0,200 – 100) µg/l\nMiedz (1,00 – 1000) µg/l\nZelazo ogolne (5,00 – 1000) µg/l\nMangan (1,00 – 100) µg/l\nMolibden (0,500 – 100) µg/l\nNikiel (1,00 – 100) µg/l\nOlow (0,200 – 100) µg/l\nCynk (2,00 – 1000) µg/l\nKobalt (0,200 – 100) µg/l\nSrebro (0,200 – 100) µg/l\nWanad (1,00 – 100) µg/l\nBeryl (0,100 – 100) µg/l\nStront (0,200 – 100) µg/l\nAntymon (0,500 – 100) µg/l\nSelen (1,00 – 100) µg/l\nCyna (1,00 – 100) µg/l\nTytan (1,00 – 100) µg/l\nTal (0,100 – 100) µg/l\nUran (0,100 – 100) µg/l\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN ISO 17294-2:2024-04","categories":["materials","water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations:","parameters_en":[{"name":"Aluminium","range":"(5,00 – 1000) µg/l"},{"name":"Arsenic","range":"(1,00 – 100) µg/l"},{"name":"Boron","range":"(10,0 – 1000) µg/l"},{"name":"Barium","range":"(0,500 – 1000) µg/l"},{"name":"Cadmium","range":"(0,020 – 100) µg/l"},{"name":"Total chromium","range":"(0,200 – 100) µg/l"},{"name":"Copper","range":"(1,00 – 1000) µg/l"},{"name":"Total iron","range":"(5,00 – 1000) µg/l"},{"name":"Manganese","range":"(1,00 – 100) µg/l"},{"name":"Molybdenum","range":"(0,500 – 100) µg/l"},{"name":"Nickel","range":"(1,00 – 100) µg/l"},{"name":"Lead","range":"(0,200 – 100) µg/l"},{"name":"Zinc","range":"(2,00 – 1000) µg/l"},{"name":"Cobalt","range":"(0,200 – 100) µg/l"},{"name":"Silver","range":"(0,200 – 100) µg/l"},{"name":"Vanadium","range":"(1,00 – 100) µg/l"},{"name":"Beryllium","range":"(0,100 – 100) µg/l"},{"name":"Strontium","range":"(0,200 – 100) µg/l"},{"name":"Antimony","range":"(0,500 – 100) µg/l"},{"name":"Selenium","range":"(1,00 – 100) µg/l"},{"name":"Tin","range":"(1,00 – 100) µg/l"},{"name":"Titanium","range":"(1,00 – 100) µg/l"},{"name":"Thallium","range":"(0,100 – 100) µg/l"},{"name":"Uranium","range":"(0,100 – 100) µg/l"}],"search_en":"Water Metal concentrations: Inductively coupled plasma mass spectrometry (ICP-MS) Aluminium Arsenic Boron Barium Cadmium Total chromium Copper Total iron Manganese Molybdenum Nickel Lead Zinc Cobalt Silver Vanadium Beryllium Strontium Antimony Selenium Tin Titanium Thallium Uranium PN-EN ISO 17294-2:2024-04","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Water","parameters_zh":[{"name":"铝","range":"(5,00 – 1000) µg/l"},{"name":"砷","range":"(1,00 – 100) µg/l"},{"name":"硼","range":"(10,0 – 1000) µg/l"},{"name":"钡","range":"(0,500 – 1000) µg/l"},{"name":"镉","range":"(0,020 – 100) µg/l"},{"name":"总铬","range":"(0,200 – 100) µg/l"},{"name":"铜","range":"(1,00 – 1000) µg/l"},{"name":"Żelazo ogólne","range":"(5,00 – 1000) µg/l"},{"name":"锰","range":"(1,00 – 100) µg/l"},{"name":"钼","range":"(0,500 – 100) µg/l"},{"name":"镍","range":"(1,00 – 100) µg/l"},{"name":"铅","range":"(0,200 – 100) µg/l"},{"name":"锌","range":"(2,00 – 1000) µg/l"},{"name":"钴","range":"(0,200 – 100) µg/l"},{"name":"银","range":"(0,200 – 100) µg/l"},{"name":"钒","range":"(1,00 – 100) µg/l"},{"name":"铍","range":"(0,100 – 100) µg/l"},{"name":"锶","range":"(0,200 – 100) µg/l"},{"name":"锑","range":"(0,500 – 100) µg/l"},{"name":"硒","range":"(1,00 – 100) µg/l"},{"name":"锡","range":"(1,00 – 100) µg/l"},{"name":"钛","range":"(1,00 – 100) µg/l"},{"name":"铊","range":"(0,100 – 100) µg/l"},{"name":"铀","range":"(0,100 – 100) µg/l"}],"search_zh":"水 金属浓度： 电感耦合等离子体质谱法（ICP-MS） 铝 砷 硼 钡 镉 总铬 铜 锰 钼 镍 铅 锌 钴 银 钒 铍 锶 锑 硒 锡 钛 铊 铀 PN-EN ISO 17294-2:2024-04","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"水","methodology_zh":"金属浓度："},{"_id":"6a82c643884ede9a1b2c2930","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie rtęci:","parameters":[{"name":"Zakres","range":"(0,020 – 1,000) µg/l"}],"technique":"Metoda atomowej spektrometrii fluorescencyjnej ( AFS)","techniques":["Metoda atomowej spektrometrii fluorescencyjnej ( AFS)"],"computed":[],"activity":"Stężenie rtęci:\nZakres (0,020 – 1,000) µg/l\nMetoda atomowej spektrometrii fluorescencyjnej ( AFS)","reference":"PN-EN ISO 17852:2009","norm_bases":["PN-EN ISO 17852:2009"],"lab_section":"Pracownia w Lublinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie rtęci:\nZakres (0,020 – 1,000) µg/l\nMetoda atomowej spektrometrii fluorescencyjnej ( AFS) PN-EN ISO 17852:2009 Woda, scieki Stezenie rteci:\nZakres (0,020 – 1,000) µg/l\nMetoda atomowej spektrometrii fluorescencyjnej ( AFS) PN-EN ISO 17852:2009","categories":["water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,020 – 1,000) µg/l"}],"search_en":"Water, wastewater Range PN-EN ISO 17852:2009","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,020 – 1,000) µg/l"}],"search_zh":"水、废水 范围 PN-EN ISO 17852:2009","test_object_zh":"水、废水"},{"_id":"6a82c643884ede9a1b2c2931","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap.1:2007","norm_bases":["PN-EN 872:2007+Ap.1:2007"],"lab_section":"Pracownia w Lublinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap.1:2007 Woda, scieki Zawiesiny ogolne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap.1:2007","categories":["water"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap.1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap.1:2007","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a82c643884ede9a1b2c2932","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(0,50 – 6,0 ) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,50 – 6,0 ) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Pracownia w Lublinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,50 – 6,0 ) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,50 – 6,0 ) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(0,50 – 6,0 ) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,50 – 6,0 ) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a82c643884ede9a1b2c2933","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(1 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Pracownia w Lublinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(1 – 6000) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(1 – 6000) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a82c643884ede9a1b2c2934","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforanów","parameters":[{"name":"Zakres","range":"(0,015 – 2,45) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforanów\nZakres (0,015 – 2,45) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010"],"lab_section":"Pracownia w Lublinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforanów\nZakres (0,015 – 2,45) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 Woda, scieki Stezenie fosforanow\nZakres (0,015 – 2,45) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","categories":["water"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phosphate concentration","parameters_en":[{"name":"Range","range":"(0,015 – 2,45) mg/l"}],"search_en":"Water, wastewater Phosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,015 – 2,45) mg/l"}],"search_zh":"水、废水 磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"磷酸盐浓度"},{"_id":"6a82c643884ede9a1b2c2935","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,005 – 40,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,005 – 40,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010"],"lab_section":"Pracownia w Lublinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,005 – 40,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,005 – 40,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","categories":["water"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,005 – 40,0) mg/l"}],"search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,005 – 40,0) mg/l"}],"search_zh":"水、废水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a82c643884ede9a1b2c2936","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,20 – 200) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,20 – 200) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Pracownia w Lublinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,20 – 200) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,20 – 200) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,20 – 200) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Titrimetric method Range PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 200) mg/l"}],"search_zh":"水、废水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a82c643884ede9a1b2c2937","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,20 – 200) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,20 – 200) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Pracownia w Lublinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres (0,20 – 200) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla\nZakres (0,20 – 200) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,20 – 200) mg/l"}],"search_en":"Water, wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 200) mg/l"}],"search_zh":"水、废水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a82c643884ede9a1b2c2938","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu ogólnego z obliczeń","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego z obliczeń","reference":"PB-26/CLB wyd.1 z dnia 16.01.2026","norm_bases":["PB-26/CLB wyd.1 z dnia 16.01.2026"],"lab_section":"Pracownia w Lublinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu ogólnego z obliczeń PB-26/CLB wyd.1 z dnia 16.01.2026 Woda, scieki Stezenie azotu ogolnego z obliczen PB-26/CLB wyd.1 z dnia 16.01.2026","categories":["water"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration calculated","search_en":"Water, wastewater Total nitrogen concentration calculated PB-26/CLB wyd.1 z dnia 16.01.2026","test_object_en":"Water, wastewater","search_zh":"水、废水 PB-26/CLB wyd.1 z dnia 16.01.2026","test_object_zh":"水、废水"},{"_id":"6a82c643884ede9a1b2c2939","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,0010 –0,25) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,0010 –0,25) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia w Lublinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotynowego\nZakres (0,0010 –0,25) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego\nZakres (0,0010 –0,25) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,0010 –0,25) mg/l"}],"search_en":"Water, wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,0010 –0,25) mg/l"}],"search_zh":"水、废水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a82c643884ede9a1b2c293a","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie anionów:","parameters":[{"name":"Siarczany","range":"(0,1 – 500) mg/l"},{"name":"Chlorki","range":"(0,1 – 3900) mg/l"},{"name":"Azot azotanowy","range":"(0,02 – 50) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów:\nZakres:\nSiarczany (0,1 – 500) mg/l\nChlorki (0,1 – 3900) mg/l\nAzot azotanowy (0,02 – 50) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Pracownia w Lublinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie anionów:\nZakres:\nSiarczany (0,1 – 500) mg/l\nChlorki (0,1 – 3900) mg/l\nAzot azotanowy (0,02 – 50) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, scieki Stezenie anionow:\nZakres:\nSiarczany (0,1 – 500) mg/l\nChlorki (0,1 – 3900) mg/l\nAzot azotanowy (0,02 – 50) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations:","parameters_en":[{"name":"Sulfates","range":"(0,1 – 500) mg/l"},{"name":"Chlorides","range":"(0,1 – 3900) mg/l"},{"name":"Nitrate nitrogen","range":"(0,02 – 50) mg/l"}],"search_en":"Water, wastewater Anion concentrations: Ion chromatography with conductometric detection (IC-CD) Sulfates Chlorides Nitrate nitrogen PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, wastewater","methodology_zh":"阴离子浓度：","parameters_zh":[{"name":"硫酸盐","range":"(0,1 – 500) mg/l"},{"name":"氯化物","range":"(0,1 – 3900) mg/l"},{"name":"硝酸盐氮","range":"(0,02 – 50) mg/l"}],"search_zh":"水、废水 阴离子浓度： 离子色谱-电导检测法（IC-CD） 硫酸盐 氯化物 硝酸盐氮 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、废水"},{"_id":"6a82c643884ede9a1b2c293b","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie ogólnego węgla organicznego","parameters":[{"name":"Zakres","range":"(1,0 – 1000) mg/l"}],"technique":"Metoda spektrometrii w zakresie podczerwieni (IR)","techniques":["Metoda spektrometrii w zakresie podczerwieni (IR)"],"computed":[],"activity":"Stężenie ogólnego węgla organicznego\nZakres (1,0 – 1000) mg/l\nMetoda spektrometrii w zakresie podczerwieni (IR)","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Pracownia w Lublinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie ogólnego węgla organicznego\nZakres (1,0 – 1000) mg/l\nMetoda spektrometrii w zakresie podczerwieni (IR) PN-EN 1484:1999 Woda, scieki Stezenie ogolnego wegla organicznego\nZakres (1,0 – 1000) mg/l\nMetoda spektrometrii w zakresie podczerwieni (IR) PN-EN 1484:1999","categories":["water"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon concentration","parameters_en":[{"name":"Range","range":"(1,0 – 1000) mg/l"}],"search_en":"Water, wastewater Total organic carbon concentration Spectrometry method in the infrared range (IR) Range PN-EN 1484:1999","technique_en":"Spectrometry method in the infrared range (IR)","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(1,0 – 1000) mg/l"}],"search_zh":"水、废水 总有机碳浓度 红外光谱法（IR） 范围 PN-EN 1484:1999","test_object_zh":"水、废水","technique_zh":"红外光谱法（IR）","methodology_zh":"总有机碳浓度"},{"_id":"6a82c643884ede9a1b2c293c","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie metali:","parameters":[{"name":"Kadm","range":"(0,0004 – 10) mg/l"},{"name":"Chrom ogólny","range":"(0,0010 – 10) mg/l"},{"name":"Miedź","range":"(0,0040 – 10) mg/l"},{"name":"Żelazo ogólne","range":"(0,0050 – 100) mg/l"},{"name":"Mangan","range":"(0,0050 – 20) mg/l"},{"name":"Nikiel","range":"(0,0020 – 10) mg/l"},{"name":"Ołów","range":"(0,0050 – 10) mg/l"},{"name":"Cynk","range":"(0,0050 – 20) mg/l"},{"name":"Cyna","range":"(0,050 – 10) mg/l"},{"name":"Sód","range":"(0,050 – 1000 )mg/l"},{"name":"Potas","range":"(0,050 – 100) mg/l"},{"name":"Wapń","range":"(0,050 – 1000) mg/l"},{"name":"Magnez","range":"(0,010 – 100) mg/l"},{"name":"Glin","range":"(0,010 – 10) mg/l"},{"name":"Arsen","range":"(0,0050 – 10) mg/l"},{"name":"Bar","range":"(0,0050 – 10) mg/l"},{"name":"Beryl","range":"(0,0002 – 10) mg/l"},{"name":"Bor","range":"(0,020 – 10) mg/l"},{"name":"Kobalt","range":"(0,0050 – 10) mg/l"},{"name":"Molibden","range":"(0,0050 – 10) mg/l"},{"name":"Selen","range":"(0,0050 – 10) mg/l"},{"name":"Stront","range":"(0,0020 – 10) mg/l"},{"name":"Wanad","range":"(0,0050 – 10) mg/l"},{"name":"Srebro","range":"(0,0050 – 10) mg/l"},{"name":"Tal","range":"(0,0020 – 10) mg/l"},{"name":"Tytan","range":"(0,0050 – 10) mg/l"},{"name":"Antymon","range":"(0,0020 – 10) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie metali:\nZakres:\nKadm (0,0004 – 10) mg/l\nChrom ogólny (0,0010 – 10) mg/l\nMiedź (0,0040 – 10) mg/l\nŻelazo ogólne (0,0050 – 100) mg/l\nMangan (0,0050 – 20) mg/l\nNikiel (0,0020 – 10) mg/l\nOłów (0,0050 – 10) mg/l\nCynk (0,0050 – 20) mg/l\nCyna (0,050 – 10) mg/l\nSód (0,050 – 1000 )mg/l\nPotas (0,050 – 100) mg/l\nWapń (0,050 – 1000) mg/l\nMagnez (0,010 – 100) mg/l\nGlin (0,010 – 10) mg/l\nArsen (0,0050 – 10) mg/l\nBar (0,0050 – 10) mg/l\nBeryl (0,0002 – 10) mg/l\nBor (0,020 – 10) mg/l\nKobalt (0,0050 – 10) mg/l\nMolibden (0,0050 – 10) mg/l\nSelen (0,0050 – 10) mg/l\nStront (0,0020 – 10) mg/l\nWanad (0,0050 – 10) mg/l\nSrebro (0,0050 – 10) mg/l\nTal (0,0020 – 10) mg/l\nTytan (0,0050 – 10) mg/l\nAntymon (0,0020 – 10) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Pracownia w Lublinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie metali:\nZakres:\nKadm (0,0004 – 10) mg/l\nChrom ogólny (0,0010 – 10) mg/l\nMiedź (0,0040 – 10) mg/l\nŻelazo ogólne (0,0050 – 100) mg/l\nMangan (0,0050 – 20) mg/l\nNikiel (0,0020 – 10) mg/l\nOłów (0,0050 – 10) mg/l\nCynk (0,0050 – 20) mg/l\nCyna (0,050 – 10) mg/l\nSód (0,050 – 1000 )mg/l\nPotas (0,050 – 100) mg/l\nWapń (0,050 – 1000) mg/l\nMagnez (0,010 – 100) mg/l\nGlin (0,010 – 10) mg/l\nArsen (0,0050 – 10) mg/l\nBar (0,0050 – 10) mg/l\nBeryl (0,0002 – 10) mg/l\nBor (0,020 – 10) mg/l\nKobalt (0,0050 – 10) mg/l\nMolibden (0,0050 – 10) mg/l\nSelen (0,0050 – 10) mg/l\nStront (0,0020 – 10) mg/l\nWanad (0,0050 – 10) mg/l\nSrebro (0,0050 – 10) mg/l\nTal (0,0020 – 10) mg/l\nTytan (0,0050 – 10) mg/l\nAntymon (0,0020 – 10) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, scieki Stezenie metali:\nZakres:\nKadm (0,0004 – 10) mg/l\nChrom ogolny (0,0010 – 10) mg/l\nMiedz (0,0040 – 10) mg/l\nZelazo ogolne (0,0050 – 100) mg/l\nMangan (0,0050 – 20) mg/l\nNikiel (0,0020 – 10) mg/l\nOlow (0,0050 – 10) mg/l\nCynk (0,0050 – 20) mg/l\nCyna (0,050 – 10) mg/l\nSod (0,050 – 1000 )mg/l\nPotas (0,050 – 100) mg/l\nWapn (0,050 – 1000) mg/l\nMagnez (0,010 – 100) mg/l\nGlin (0,010 – 10) mg/l\nArsen (0,0050 – 10) mg/l\nBar (0,0050 – 10) mg/l\nBeryl (0,0002 – 10) mg/l\nBor (0,020 – 10) mg/l\nKobalt (0,0050 – 10) mg/l\nMolibden (0,0050 – 10) mg/l\nSelen (0,0050 – 10) mg/l\nStront (0,0020 – 10) mg/l\nWanad (0,0050 – 10) mg/l\nSrebro (0,0050 – 10) mg/l\nTal (0,0020 – 10) mg/l\nTytan (0,0050 – 10) mg/l\nAntymon (0,0020 – 10) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["materials","water"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations:","parameters_en":[{"name":"Cadmium","range":"(0,0004 – 10) mg/l"},{"name":"Total chromium","range":"(0,0010 – 10) mg/l"},{"name":"Copper","range":"(0,0040 – 10) mg/l"},{"name":"Total iron","range":"(0,0050 – 100) mg/l"},{"name":"Manganese","range":"(0,0050 – 20) mg/l"},{"name":"Nickel","range":"(0,0020 – 10) mg/l"},{"name":"Lead","range":"(0,0050 – 10) mg/l"},{"name":"Zinc","range":"(0,0050 – 20) mg/l"},{"name":"Tin","range":"(0,050 – 10) mg/l"},{"name":"Sodium","range":"(0,050 – 1000 )mg/l"},{"name":"Potassium","range":"(0,050 – 100) mg/l"},{"name":"Calcium","range":"(0,050 – 1000) mg/l"},{"name":"Magnesium","range":"(0,010 – 100) mg/l"},{"name":"Aluminium","range":"(0,010 – 10) mg/l"},{"name":"Arsenic","range":"(0,0050 – 10) mg/l"},{"name":"Barium","range":"(0,0050 – 10) mg/l"},{"name":"Beryllium","range":"(0,0002 – 10) mg/l"},{"name":"Boron","range":"(0,020 – 10) mg/l"},{"name":"Cobalt","range":"(0,0050 – 10) mg/l"},{"name":"Molybdenum","range":"(0,0050 – 10) mg/l"},{"name":"Selenium","range":"(0,0050 – 10) mg/l"},{"name":"Strontium","range":"(0,0020 – 10) mg/l"},{"name":"Vanadium","range":"(0,0050 – 10) mg/l"},{"name":"Silver","range":"(0,0050 – 10) mg/l"},{"name":"Thallium","range":"(0,0020 – 10) mg/l"},{"name":"Titanium","range":"(0,0050 – 10) mg/l"},{"name":"Antimony","range":"(0,0020 – 10) mg/l"}],"search_en":"Water, wastewater Metal concentrations: Inductively coupled plasma optical emission spectrometry (ICP-OES) Cadmium Total chromium Copper Total iron Manganese Nickel Lead Zinc Tin Sodium Potassium Calcium Magnesium Aluminium Arsenic Barium Beryllium Boron Cobalt Molybdenum Selenium Strontium Vanadium Silver Thallium Titanium Antimony PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water, wastewater","parameters_zh":[{"name":"镉","range":"(0,0004 – 10) mg/l"},{"name":"总铬","range":"(0,0010 – 10) mg/l"},{"name":"铜","range":"(0,0040 – 10) mg/l"},{"name":"Żelazo ogólne","range":"(0,0050 – 100) mg/l"},{"name":"锰","range":"(0,0050 – 20) mg/l"},{"name":"镍","range":"(0,0020 – 10) mg/l"},{"name":"铅","range":"(0,0050 – 10) mg/l"},{"name":"锌","range":"(0,0050 – 20) mg/l"},{"name":"锡","range":"(0,050 – 10) mg/l"},{"name":"钠","range":"(0,050 – 1000 )mg/l"},{"name":"钾","range":"(0,050 – 100) mg/l"},{"name":"钙","range":"(0,050 – 1000) mg/l"},{"name":"镁","range":"(0,010 – 100) mg/l"},{"name":"铝","range":"(0,010 – 10) mg/l"},{"name":"砷","range":"(0,0050 – 10) mg/l"},{"name":"钡","range":"(0,0050 – 10) mg/l"},{"name":"铍","range":"(0,0002 – 10) mg/l"},{"name":"硼","range":"(0,020 – 10) mg/l"},{"name":"钴","range":"(0,0050 – 10) mg/l"},{"name":"钼","range":"(0,0050 – 10) mg/l"},{"name":"硒","range":"(0,0050 – 10) mg/l"},{"name":"锶","range":"(0,0020 – 10) mg/l"},{"name":"钒","range":"(0,0050 – 10) mg/l"},{"name":"银","range":"(0,0050 – 10) mg/l"},{"name":"铊","range":"(0,0020 – 10) mg/l"},{"name":"钛","range":"(0,0050 – 10) mg/l"},{"name":"锑","range":"(0,0020 – 10) mg/l"}],"search_zh":"水、废水 金属浓度： 电感耦合等离子体原子发射光谱法（ICP-OES） 镉 总铬 铜 锰 镍 铅 锌 锡 钠 钾 钙 镁 铝 砷 钡 铍 硼 钴 钼 硒 锶 钒 银 铊 钛 锑 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水、废水","methodology_zh":"金属浓度："},{"_id":"6a82c643884ede9a1b2c293d","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Ścieki","methodology":"Indeks oleju mineralnego","parameters":[{"name":"Zakres","range":"(1,0 – 150) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Indeks oleju mineralnego\nZakres (1,0 – 150) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":"Pracownia w Lublinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Indeks oleju mineralnego\nZakres (1,0 – 150) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Scieki Indeks oleju mineralnego\nZakres (1,0 – 150) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil index","parameters_en":[{"name":"Range","range":"(1,0 – 150) mg/l"}],"search_en":"Wastewater Mineral oil index Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(1,0 – 150) mg/l"}],"search_zh":"污水 矿物油指数 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"污水","methodology_zh":"矿物油指数"},{"_id":"6a82c643884ede9a1b2c293e","lab_id":"69ad52a3de79e566650fb125","country":"PL","accr_number":"AB 118","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu ChZT-Cr","parameters":[{"name":"Zakres","range":"(10 – 2400) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (10 – 2400) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia w Lublinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (10 – 2400) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (10 – 2400) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand COD-Cr","parameters_en":[{"name":"Range","range":"(10 – 2400) mg/l O2"}],"search_en":"Wastewater Chemical oxygen demand COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(10 – 2400) mg/l O2"}],"search_zh":"污水 化学需氧量 COD-Cr 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"化学需氧量 COD-Cr"}],"has_pdf":true}