{"lab":{"_id":"69ad52a3de79e566650fb600","accr_number":"AB 1174","country":"PL","accr_body":"PCA","address":"LABORATORIUM, ul. Energetyczna 11, 62-600 Koło","categories":["water","microbiology"],"city":"Koło","imported_at":"2026-03-08T10:42:43.265Z","methods_count":33,"name":"MIEJSKI ZAKŁAD WODOCIĄGÓW I KANALIZACJI Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1174.pdf"],"scope_summary":"","search_text":"miejski zakład wodociągów i kanalizacji sp. z o.o. laboratorium, ul. energetyczna 11, 62-600 koło water pharma electronics other microbiology automotive materials","status":"active","updated_at":"2026-03-08T14:50:21.072Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-14T13:54:21.380Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201174,podmiot.html","parse_date":"2026-08-14T13:54:21.380Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of drinking water, sewage"},{"codes":"C/28","pl":"Badania chemiczne wody","en":"Chemical tests of water"},{"codes":"N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of drinking water, sewage"},{"codes":"N/28","pl":"Badania właściwości fizycznych wody","en":"Tests of physical properties of water"},{"codes":"K/28/P; K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Microbiological tests and sampling of water, drinking water"}],"issue":{"no":"21","date":"30.03.2026"},"map_coord":[52.21439,18.60365],"map_geo":"nominatim-street","lab_locations":[{"name":"Laboratorium","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/14/3e9b9c77fed98e86dc260248c0c28514/AB%201174.pdf","has_en":true,"category_counts":{"water":33,"microbiology":3},"category_scores":{"water":30.25,"microbiology":0.25},"has_zh":true,"lab_locations_zh":[{"name":"实验室","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7f1e0dbc25eed9be28d930","lab_id":"69ad52a3de79e566650fb600","country":"PL","accr_number":"AB 1174","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10 – 2000) µS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (10 – 2000) µS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (10 – 2000) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (10 – 2000) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(10 – 2000) µS/cm"}],"search_en":"Water, Water intended for human consumption Electrical conductivity Conductometric method Laboratory Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10 – 2000) µS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 实验室 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f1e0dbc25eed9be28d931","lab_id":"69ad52a3de79e566650fb600","country":"PL","accr_number":"AB 1174","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(2,5 – 70) mg/l Pt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa\nZakres (2,5 – 70) mg/l Pt\nMetoda wizualna","reference":"PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D","norm_bases":["PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Barwa\nZakres (2,5 – 70) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D Woda, Woda do spozycia przez ludzi Barwa\nZakres (2,5 – 70) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(2,5 – 70) mg/l Pt"}],"search_en":"Water, Water intended for human consumption Colour Visual method Laboratory Range PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D","technique_en":"Visual method","test_object_en":"Water, Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(2,5 – 70) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 目视法 实验室 范围 PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D","technique_zh":"目视法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f1e0dbc25eed9be28d932","lab_id":"69ad52a3de79e566650fb600","country":"PL","accr_number":"AB 1174","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(10 – 737) mg/l CaCO3"},{"name":"Zakres","range":"(0,10 – 7,37) mmol/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres:\nZakres (10 – 737) mg/l CaCO3\nZakres (0,10 – 7,37) mmol/l\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres:\nZakres (10 – 737) mg/l CaCO3\nZakres (0,10 – 7,37) mmol/l\nMetoda miareczkowa PN-ISO 6059:1999 Woda, Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres:\nZakres (10 – 737) mg/l CaCO3\nZakres (0,10 – 7,37) mmol/l\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(10 – 737) mg/l CaCO3"},{"name":"Range","range":"(0,10 – 7,37) mmol/l"}],"search_en":"Water, Water intended for human consumption Total content of calcium and magnesium (total hardness) Titrimetric method Laboratory Range Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(10 – 737) mg/l CaCO3"},{"name":"范围","range":"(0,10 – 7,37) mmol/l"}],"search_zh":"水、生活饮用水 钙与镁总量（总硬度） 滴定法 实验室 范围 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f1e0dbc25eed9be28d933","lab_id":"69ad52a3de79e566650fb600","country":"PL","accr_number":"AB 1174","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,010 – 2,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (0,010 – 2,00) mg/l\nMetoda spektrofotometryczna","reference":"Metoda testu MERCK nr 1.01846.0001 sierpień 2024 r.","norm_bases":["Metoda testu MERCK nr 1.01846.0001 sierpień 2024 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie manganu\nZakres (0,010 – 2,00) mg/l\nMetoda spektrofotometryczna Metoda testu MERCK nr 1.01846.0001 sierpień 2024 r. Woda, Woda do spozycia przez ludzi Stezenie manganu\nZakres (0,010 – 2,00) mg/l\nMetoda spektrofotometryczna Metoda testu MERCK nr 1.01846.0001 sierpien 2024 r.","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(0,010 – 2,00) mg/l"}],"search_en":"Water, Water intended for human consumption Manganese concentration Spectrophotometric method Laboratory Range Metoda testu MERCK nr 1.01846.0001 sierpień 2024 r.","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 2,00) mg/l"}],"search_zh":"水、生活饮用水 锰浓度 分光光度法 实验室 范围 Metoda testu MERCK nr 1.01846.0001 sierpień 2024 r.","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f1e0dbc25eed9be28d934","lab_id":"69ad52a3de79e566650fb600","country":"PL","accr_number":"AB 1174","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie wapnia","parameters":[{"name":"Zakres","range":"(2,00 – 200) mg/l"},{"name":"Zakres","range":"(0,05 – 5,0) mmol/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie wapnia\nZakres:\nZakres (2,00 – 200) mg/l\nZakres (0,05 – 5,0) mmol/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie wapnia\nZakres:\nZakres (2,00 – 200) mg/l\nZakres (0,05 – 5,0) mmol/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda, Woda do spozycia przez ludzi Stezenie wapnia\nZakres:\nZakres (2,00 – 200) mg/l\nZakres (0,05 – 5,0) mmol/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Calcium concentration","parameters_en":[{"name":"Range","range":"(2,00 – 200) mg/l"},{"name":"Range","range":"(0,05 – 5,0) mmol/l"}],"search_en":"Water, Water intended for human consumption Calcium concentration Titrimetric method Laboratory Range Range PN-ISO 6058:1999","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(2,00 – 200) mg/l"},{"name":"范围","range":"(0,05 – 5,0) mmol/l"}],"search_zh":"水、生活饮用水 钙浓度 滴定法 实验室 范围 范围 PN-ISO 6058:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","methodology_zh":"钙浓度"},{"_id":"6a7f1e0dbc25eed9be28d935","lab_id":"69ad52a3de79e566650fb600","country":"PL","accr_number":"AB 1174","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie magnezu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie magnezu (z obliczeń)","reference":"PN-C-04554-4:1999","norm_bases":["PN-C-04554-4:1999"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie magnezu (z obliczeń) PN-C-04554-4:1999 Woda, Woda do spozycia przez ludzi Stezenie magnezu (z obliczen) PN-C-04554-4:1999","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Magnesium concentration (calculated)","search_en":"Water, Water intended for human consumption Magnesium concentration (calculated) Laboratory PN-C-04554-4:1999","test_object_en":"Water, Water intended for human consumption","lab_section_zh":"实验室","search_zh":"水、生活饮用水 镁浓度（计算值） 实验室 PN-C-04554-4:1999","test_object_zh":"水、生活饮用水","methodology_zh":"镁浓度（计算值）"},{"_id":"6a7f1e0dbc25eed9be28d936","lab_id":"69ad52a3de79e566650fb600","country":"PL","accr_number":"AB 1174","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 – 40) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 – 40) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Mętność\nZakres (0,10 – 40) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, Woda do spozycia przez ludzi Metnosc\nZakres (0,10 – 40) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,10 – 40) NTU"}],"search_en":"Water, Water intended for human consumption Turbidity Nephelometric method Laboratory Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water, Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 – 40) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 实验室 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水"},{"_id":"6a7f1e0dbc25eed9be28d937","lab_id":"69ad52a3de79e566650fb600","country":"PL","accr_number":"AB 1174","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,05 – 0,80) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,05 – 0,80) mg/l\nMetoda kolorymetryczna","reference":"PB/PF-18 wyd. 04 z dnia 05.12.2022 r.","norm_bases":["PB/PF-18 wyd. 04 z dnia 05.12.2022 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie chloru wolnego\nZakres (0,05 – 0,80) mg/l\nMetoda kolorymetryczna PB/PF-18 wyd. 04 z dnia 05.12.2022 r. Woda, Woda do spozycia przez ludzi Stezenie chloru wolnego\nZakres (0,05 – 0,80) mg/l\nMetoda kolorymetryczna PB/PF-18 wyd. 04 z dnia 05.12.2022 r.","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,05 – 0,80) mg/l"}],"search_en":"Water, Water intended for human consumption Free chlorine concentration Colorimetric method Laboratory Range PB/PF-18 wyd. 04 z dnia 05.12.2022 r.","technique_en":"Colorimetric method","test_object_en":"Water, Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 0,80) mg/l"}],"search_zh":"水、生活饮用水 游离氯浓度 比色法 实验室 范围 PB/PF-18 wyd. 04 z dnia 05.12.2022 r.","technique_zh":"比色法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f1e0dbc25eed9be28d938","lab_id":"69ad52a3de79e566650fb600","country":"PL","accr_number":"AB 1174","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12/A1:2017-04"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04 Woda, Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","categories":["water","microbiology"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Coliform bacteria count","search_en":"Water, Water intended for human consumption Coliform bacteria count Membrane filtration method Laboratory PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 实验室 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f1e0dbc25eed9be28d939","lab_id":"69ad52a3de79e566650fb600","country":"PL","accr_number":"AB 1174","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12/A1:2017-04"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04 Woda, Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","categories":["water","microbiology"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Escherichia coli count","search_en":"Water, Water intended for human consumption Escherichia coli count Membrane filtration method Laboratory PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 实验室 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f1e0dbc25eed9be28d93a","lab_id":"69ad52a3de79e566650fb600","country":"PL","accr_number":"AB 1174","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, Woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Intestinal enterococci count","search_en":"Water, Water intended for human consumption Intestinal enterococci count Membrane filtration method Laboratory PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"粪肠球菌计数","search_zh":"水、生活饮用水 粪肠球菌计数 膜过滤法 实验室 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f1e0dbc25eed9be28d93b","lab_id":"69ad52a3de79e566650fb600","country":"PL","accr_number":"AB 1174","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 22°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 22°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total viable count at 22°C","search_en":"Water, Water intended for human consumption Total viable count at 22°C Plate method (pour plate) Laboratory PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water, Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"22°C 微生物总数","search_zh":"水、生活饮用水 22°C 微生物总数 平板法（倾注培养） 实验室 PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水"},{"_id":"6a7f1e0dbc25eed9be28d93c","lab_id":"69ad52a3de79e566650fb600","country":"PL","accr_number":"AB 1174","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 36°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 36°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 36°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 36°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total viable count at 36°C","search_en":"Water, Water intended for human consumption Total viable count at 36°C Plate method (pour plate) Laboratory PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water, Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"36°C 微生物总数","search_zh":"水、生活饮用水 36°C 微生物总数 平板法（倾注培养） 实验室 PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水"},{"_id":"6a7f1e0dbc25eed9be28d93d","lab_id":"69ad52a3de79e566650fb600","country":"PL","accr_number":"AB 1174","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,020 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,020 – 100) mg/l\nMetoda spektrofotometryczna","reference":"Metoda testu MERCK nr 1.14752.0001 luty 2024 r.","norm_bases":["Metoda testu MERCK nr 1.14752.0001 luty 2024 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie jonu amonowego\nZakres (0,020 – 100) mg/l\nMetoda spektrofotometryczna Metoda testu MERCK nr 1.14752.0001 luty 2024 r. Woda, Woda do spozycia przez ludzi, Scieki Stezenie jonu amonowego\nZakres (0,020 – 100) mg/l\nMetoda spektrofotometryczna Metoda testu MERCK nr 1.14752.0001 luty 2024 r.","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,020 – 100) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Ammonium ion concentration Spectrophotometric method Laboratory Range Metoda testu MERCK nr 1.14752.0001 luty 2024 r.","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","lab_section_zh":"实验室","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,020 – 100) mg/l"}],"search_zh":"水、生活饮用水、废水 铵离子浓度 分光光度法 实验室 范围 Metoda testu MERCK nr 1.14752.0001 luty 2024 r.","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a7f1e0dbc25eed9be28d93e","lab_id":"69ad52a3de79e566650fb600","country":"PL","accr_number":"AB 1174","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,020 – 9,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,020 – 9,00) mg/l\nMetoda spektrofotometryczna","reference":"Metoda testu MERCK nr 1.14776.0001 luty 2024 r.","norm_bases":["Metoda testu MERCK nr 1.14776.0001 luty 2024 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie azotynów\nZakres (0,020 – 9,00) mg/l\nMetoda spektrofotometryczna Metoda testu MERCK nr 1.14776.0001 luty 2024 r. Woda, Woda do spozycia przez ludzi, Scieki Stezenie azotynow\nZakres (0,020 – 9,00) mg/l\nMetoda spektrofotometryczna Metoda testu MERCK nr 1.14776.0001 luty 2024 r.","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,020 – 9,00) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Nitrite concentration Spectrophotometric method Laboratory Range Metoda testu MERCK nr 1.14776.0001 luty 2024 r.","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","lab_section_zh":"实验室","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,020 – 9,00) mg/l"}],"search_zh":"水、生活饮用水、废水 亚硝酸盐浓度 分光光度法 实验室 范围 Metoda testu MERCK nr 1.14776.0001 luty 2024 r.","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a7f1e0dbc25eed9be28d93f","lab_id":"69ad52a3de79e566650fb600","country":"PL","accr_number":"AB 1174","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(1,0 – 170) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (1,0 – 170) mg/l\nMetoda spektrofotometryczna","reference":"Metoda testu MERCK nr 1.14773.0001 lipiec 2024 r.","norm_bases":["Metoda testu MERCK nr 1.14773.0001 lipiec 2024 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie azotanów\nZakres (1,0 – 170) mg/l\nMetoda spektrofotometryczna Metoda testu MERCK nr 1.14773.0001 lipiec 2024 r. Woda, Woda do spozycia przez ludzi, Scieki Stezenie azotanow\nZakres (1,0 – 170) mg/l\nMetoda spektrofotometryczna Metoda testu MERCK nr 1.14773.0001 lipiec 2024 r.","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(1,0 – 170) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Nitrate concentration Spectrophotometric method Laboratory Range Metoda testu MERCK nr 1.14773.0001 lipiec 2024 r.","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","lab_section_zh":"实验室","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 170) mg/l"}],"search_zh":"水、生活饮用水、废水 硝酸盐浓度 分光光度法 实验室 范围 Metoda testu MERCK nr 1.14773.0001 lipiec 2024 r.","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a7f1e0dbc25eed9be28d940","lab_id":"69ad52a3de79e566650fb600","country":"PL","accr_number":"AB 1174","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,25 – 25,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,25 – 25,0) mg/l\nMetoda spektrofotometryczna","reference":"Metoda testu MERCK nr 1.14848.0001 styczeń 2021 r.","norm_bases":["Metoda testu MERCK nr 1.14848.0001 styczeń 2021 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie fosforu ogólnego\nZakres (0,25 – 25,0) mg/l\nMetoda spektrofotometryczna Metoda testu MERCK nr 1.14848.0001 styczeń 2021 r. Woda, Woda do spozycia przez ludzi, Scieki Stezenie fosforu ogolnego\nZakres (0,25 – 25,0) mg/l\nMetoda spektrofotometryczna Metoda testu MERCK nr 1.14848.0001 styczen 2021 r.","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,25 – 25,0) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Total phosphorus concentration Spectrophotometric method Laboratory Range Metoda testu MERCK nr 1.14848.0001 styczeń 2021 r.","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","lab_section_zh":"实验室","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,25 – 25,0) mg/l"}],"search_zh":"水、生活饮用水、废水 总磷浓度 分光光度法 实验室 范围 Metoda testu MERCK nr 1.14848.0001 styczeń 2021 r.","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a7f1e0dbc25eed9be28d941","lab_id":"69ad52a3de79e566650fb600","country":"PL","accr_number":"AB 1174","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, Woda do spozycia przez ludzi, Scieki Zawiesiny ogolne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Total suspended solids (TSS) Gravimetric method Laboratory Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, Water intended for human consumption, Wastewater","lab_section_zh":"实验室","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"水、生活饮用水、废水 总悬浮物 重量法 实验室 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a7f1e0dbc25eed9be28d942","lab_id":"69ad52a3de79e566650fb600","country":"PL","accr_number":"AB 1174","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr","parameters":[{"name":"Zakres","range":"(4,0 – 5000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (4,0 – 5000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (4,0 – 5000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, Woda do spozycia przez ludzi, Scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (4,0 – 5000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chemical oxygen demand - COD-Cr","parameters_en":[{"name":"Range","range":"(4,0 – 5000) mg/l O2"}],"search_en":"Water, Water intended for human consumption, Wastewater Chemical oxygen demand - COD-Cr Spectrophotometric method Laboratory Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(4,0 – 5000) mg/l O2"}],"search_zh":"水、生活饮用水、废水 化学需氧量（COD-Cr） 分光光度法 实验室 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a7f1e0dbc25eed9be28d943","lab_id":"69ad52a3de79e566650fb600","country":"PL","accr_number":"AB 1174","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,00 – 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,00 – 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie chlorków\nZakres (5,00 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, Woda do spozycia przez ludzi, Scieki Stezenie chlorkow\nZakres (5,00 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,00 – 400) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Chloride concentration Titrimetric method Laboratory Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption, Wastewater","lab_section_zh":"实验室","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,00 – 400) mg/l"}],"search_zh":"水、生活饮用水、废水 氯化物浓度 滴定法 实验室 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a7f1e0dbc25eed9be28d944","lab_id":"69ad52a3de79e566650fb600","country":"PL","accr_number":"AB 1174","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(5 – 250) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczanów\nZakres (5 – 250) mg/l\nMetoda spektrofotometryczna","reference":"Metoda testu MERCK nr 1.14548.0001 maj 2024 r.","norm_bases":["Metoda testu MERCK nr 1.14548.0001 maj 2024 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie siarczanów\nZakres (5 – 250) mg/l\nMetoda spektrofotometryczna Metoda testu MERCK nr 1.14548.0001 maj 2024 r. Woda, Woda do spozycia przez ludzi, Scieki Stezenie siarczanow\nZakres (5 – 250) mg/l\nMetoda spektrofotometryczna Metoda testu MERCK nr 1.14548.0001 maj 2024 r.","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(5 – 250) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Sulfate concentration Spectrophotometric method Laboratory Range Metoda testu MERCK nr 1.14548.0001 maj 2024 r.","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","lab_section_zh":"实验室","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(5 – 250) mg/l"}],"search_zh":"水、生活饮用水、废水 硫酸盐浓度 分光光度法 实验室 范围 Metoda testu MERCK nr 1.14548.0001 maj 2024 r.","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a7f1e0dbc25eed9be28d945","lab_id":"69ad52a3de79e566650fb600","country":"PL","accr_number":"AB 1174","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,010 – 50,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,010 – 50,0) mg/l\nMetoda spektrofotometryczna","reference":"Metoda testu MERCK nr 1.14761.0001 marzec 2024 r.","norm_bases":["Metoda testu MERCK nr 1.14761.0001 marzec 2024 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie żelaza ogólnego\nZakres (0,010 – 50,0) mg/l\nMetoda spektrofotometryczna Metoda testu MERCK nr 1.14761.0001 marzec 2024 r. Woda, Woda do spozycia przez ludzi, Scieki Stezenie zelaza ogolnego\nZakres (0,010 – 50,0) mg/l\nMetoda spektrofotometryczna Metoda testu MERCK nr 1.14761.0001 marzec 2024 r.","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,010 – 50,0) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Total iron concentration Spectrophotometric method Laboratory Range Metoda testu MERCK nr 1.14761.0001 marzec 2024 r.","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","lab_section_zh":"实验室","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 50,0) mg/l"}],"search_zh":"水、生活饮用水、废水 总铁浓度 分光光度法 实验室 范围 Metoda testu MERCK nr 1.14761.0001 marzec 2024 r.","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a7f1e0dbc25eed9be28d946","lab_id":"69ad52a3de79e566650fb600","country":"PL","accr_number":"AB 1174","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":"Badania wykonywane w siedzibie i poza siedzibą laboratorium","flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki pH\nZakres 4,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Woda do spozycia przez ludzi, Scieki pH\nZakres 4,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 12,0"}],"search_en":"Water, Water intended for human consumption, Wastewater pH Potentiometric method Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","lab_section_zh":"实验室","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 12,0"}],"search_zh":"水、生活饮用水、废水 pH 值 电位法 实验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a7f1e0dbc25eed9be28d947","lab_id":"69ad52a3de79e566650fb600","country":"PL","accr_number":"AB 1174","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(0,5 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, Woda do spozycia przez ludzi, Scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(0,5 – 6,0) mg/l O2"}],"search_en":"Water, Water intended for human consumption, Wastewater Biochemical oxygen demand - BOD5 Electrochemical method Laboratory Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, Water intended for human consumption, Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,5 – 6,0) mg/l O2"}],"search_zh":"水、生活饮用水、废水 五日生化需氧量（BOD5） 电化学法 实验室 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、生活饮用水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a7f1e0dbc25eed9be28d948","lab_id":"69ad52a3de79e566650fb600","country":"PL","accr_number":"AB 1174","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(0,5 – 150) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (0,5 – 150) mg/l\nMetoda spektrofotometryczna","reference":"Metoda testu MERCK nr 1.14537.0001 wrzesień 2024 r.","norm_bases":["Metoda testu MERCK nr 1.14537.0001 wrzesień 2024 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego\nZakres (0,5 – 150) mg/l\nMetoda spektrofotometryczna Metoda testu MERCK nr 1.14537.0001 wrzesień 2024 r. Scieki Stezenie azotu ogolnego\nZakres (0,5 – 150) mg/l\nMetoda spektrofotometryczna Metoda testu MERCK nr 1.14537.0001 wrzesien 2024 r.","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,5 – 150) mg/l"}],"search_en":"Wastewater Total nitrogen concentration Spectrophotometric method Laboratory Range Metoda testu MERCK nr 1.14537.0001 wrzesień 2024 r.","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(0,5 – 150) mg/l"}],"search_zh":"污水 总氮浓度 分光光度法 实验室 范围 Metoda testu MERCK nr 1.14537.0001 wrzesień 2024 r.","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7f1e0dbc25eed9be28d949","lab_id":"69ad52a3de79e566650fb600","country":"PL","accr_number":"AB 1174","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(1 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(1 – 6000) mg/l O2"}],"search_en":"Wastewater Biochemical oxygen demand - BOD5 Electrochemical method Laboratory Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(1 – 6000) mg/l O2"}],"search_zh":"污水 五日生化需氧量（BOD5） 电化学法 实验室 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a7f1e0dbc25eed9be28d94a","lab_id":"69ad52a3de79e566650fb600","country":"PL","accr_number":"AB 1174","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie substancji ekstrahujących się eterem naftowym","parameters":[{"name":"Zakres","range":"(5 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym\nZakres (5 – 1000) mg/l\nMetoda wagowa","reference":"PN-86/C-04573/01","norm_bases":["PN-86/C-04573/01"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie substancji ekstrahujących się eterem naftowym\nZakres (5 – 1000) mg/l\nMetoda wagowa PN-86/C-04573/01 Scieki Stezenie substancji ekstrahujacych sie eterem naftowym\nZakres (5 – 1000) mg/l\nMetoda wagowa PN-86/C-04573/01","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Concentration of substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(5 – 1000) mg/l"}],"search_en":"Wastewater Concentration of substances extractable with petroleum ether Gravimetric method Laboratory Range PN-86/C-04573/01","technique_en":"Gravimetric method","test_object_en":"Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(5 – 1000) mg/l"}],"search_zh":"污水 石油醚可萃取物浓度 重量法 实验室 范围 PN-86/C-04573/01","technique_zh":"重量法","test_object_zh":"污水","methodology_zh":"石油醚可萃取物浓度"},{"_id":"6a7f1e0dbc25eed9be28d94b","lab_id":"69ad52a3de79e566650fb600","country":"PL","accr_number":"AB 1174","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Water intended for human consumption Sampling for chemical and physical testing Laboratory PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 实验室 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a7f1e0dbc25eed9be28d94c","lab_id":"69ad52a3de79e566650fb600","country":"PL","accr_number":"AB 1174","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(1,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (1,0 – 50,0) °C","reference":"PN-C-04584:1977","norm_bases":["PN-C-04584:1977"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Temperatura\nZakres (1,0 – 50,0) °C PN-C-04584:1977 Woda do spozycia przez ludzi Temperatura\nZakres (1,0 – 50,0) °C PN-C-04584:1977","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(1,0 – 50,0) °C"}],"search_en":"Water intended for human consumption Temperature Laboratory Range PN-C-04584:1977","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(1,0 – 50,0) °C"}],"search_zh":"生活饮用水 温度 实验室 范围 PN-C-04584:1977","test_object_zh":"生活饮用水","methodology_zh":"温度"},{"_id":"6a7f1e0dbc25eed9be28d94d","lab_id":"69ad52a3de79e566650fb600","country":"PL","accr_number":"AB 1174","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna i automatyczna","techniques":["Metoda manualna i automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna i automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual and automatic method Laboratory PN-ISO 5667-10:2021-11","technique_en":"Manual and automatic method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手工与自动法 实验室 PN-ISO 5667-10:2021-11","test_object_zh":"污水","technique_zh":"手工与自动法"},{"_id":"6a7f1e0dbc25eed9be28d94e","lab_id":"69ad52a3de79e566650fb600","country":"PL","accr_number":"AB 1174","accr_body":"PCA","test_object":"Ścieki","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(1,0 - 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (1,0 - 50,0) °C","reference":"PN-C-04584:1977","norm_bases":["PN-C-04584:1977"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Temperatura\nZakres (1,0 - 50,0) °C PN-C-04584:1977 Scieki Temperatura\nZakres (1,0 - 50,0) °C PN-C-04584:1977","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(1,0 - 50,0) °C"}],"search_en":"Wastewater Temperature Laboratory Range PN-C-04584:1977","test_object_en":"Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(1,0 - 50,0) °C"}],"search_zh":"污水 温度 实验室 范围 PN-C-04584:1977","test_object_zh":"污水","methodology_zh":"温度"},{"_id":"6a7f1e0dbc25eed9be28d94f","lab_id":"69ad52a3de79e566650fb600","country":"PL","accr_number":"AB 1174","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.3, 4.4.5, 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.3, 4.4.5, 4.4.6"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.3, 4.4.5, 4.4.6 Woda, Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem p. 4.4.3, 4.4.5, 4.4.6","categories":["water","microbiology"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for microbiological testing","search_en":"Water, Water intended for human consumption Sampling for microbiological testing Laboratory PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.3, 4.4.5, 4.4.6","test_object_en":"Water, Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"微生物检测用样品采集","search_zh":"水、生活饮用水 微生物检测用样品采集 实验室 PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.3, 4.4.5, 4.4.6","test_object_zh":"水、生活饮用水"},{"_id":"6a7f1e0dbc25eed9be28d950","lab_id":"69ad52a3de79e566650fb600","country":"PL","accr_number":"AB 1174","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(1,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (1,0 – 50,0) °C","reference":"PN-C-04584:1977","norm_bases":["PN-C-04584:1977"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Temperatura\nZakres (1,0 – 50,0) °C PN-C-04584:1977 Woda, Woda do spozycia przez ludzi Temperatura\nZakres (1,0 – 50,0) °C PN-C-04584:1977","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(1,0 – 50,0) °C"}],"search_en":"Water, Water intended for human consumption Temperature Laboratory Range PN-C-04584:1977","test_object_en":"Water, Water intended for human consumption","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(1,0 – 50,0) °C"}],"search_zh":"水、生活饮用水 温度 实验室 范围 PN-C-04584:1977","test_object_zh":"水、生活饮用水","methodology_zh":"温度"}],"has_pdf":true}