{"lab":{"_id":"69ad52a3de79e566650fb5ea","accr_number":"AB 1158","country":"PL","accr_body":"PCA","address":"ul. Wojewódzka 19, 40-026 Katowice, WYDZIAŁ BADANIA WODY, ul. Żeliwna 38","categories":["water","microbiology"],"city":"Katowice","imported_at":"2026-03-08T10:42:43.265Z","methods_count":105,"name":"GÓRNOŚLĄSKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW S.A.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1158.pdf"],"scope_summary":"","search_text":"górnośląskie przedsiębiorstwo wodociągów s.a. ul. wojewódzka 19, 40-026 katowice, wydział badania wody, ul. żeliwna 38 water other pharma electronics materials microbiology automotive","status":"active","updated_at":"2026-03-08T14:50:20.030Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:20.030Z","email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%201158,podmiot.html","needs_review":true,"review_reason":"e-mail niepewny (low) — zweryfikuj","parse_date":"2026-07-17T16:19:06.571Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"C/28/P; C/29/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Chemical tests and sampling of water, drinking water"},{"codes":"C/30","pl":"Badania chemiczne ścieków","en":"Chemical tests of sewage"},{"codes":"K/28/P; K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Microbiological tests and sampling of water, drinking water"},{"codes":"N/28/P; N/29/P; N/30","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of water, drinking water, sewage"},{"codes":"Q/28/P; Q/29/P","pl":"Badania sensoryczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Senory tests and sampling of water, drinking water"}],"issue":{"no":"18","date":"02.03.2026"},"map_coord":[50.255852,19.024618],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":105,"microbiology":6,"materials":3},"category_scores":{"water":96.71,"microbiology":0.32,"materials":0.08},"has_zh":true},"methods":[{"_id":"6a5a55fa9af9f73f38252a22","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych, fizycznych (w tym sensorycznych)","methodology_en":"Sampling for chemical, physical (including sensory) testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych (w tym sensorycznych)","reference":"PN-ISO 5667-5:2017-10 PN-ISO 5667-4:2017-10 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.3","norm_bases":["PN-ISO 5667-5:2017-10 PN-ISO 5667-4:2017-10 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych, fizycznych (w tym sensorycznych) PN-ISO 5667-5:2017-10 PN-ISO 5667-4:2017-10 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.3 Woda Pobieranie probek do badan chemicznych, fizycznych (w tym sensorycznych) PN-ISO 5667-5:2017-10 PN-ISO 5667-4:2017-10 PN-EN ISO 5667-6:2016-12 z wylaczeniem pkt 7.3","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Sampling for chemical, physical (including sensory) testing PN-ISO 5667-5:2017-10 PN-ISO 5667-4:2017-10 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.3","search_zh":"水 用于化学、物理（含感官）检验的采样 PN-ISO 5667-5:2017-10 PN-ISO 5667-4:2017-10 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.3","test_object_zh":"水","methodology_zh":"用于化学、物理（含感官）检验的采样"},{"_id":"6a5a55fa9af9f73f38252a23","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Mętność Zakres: (0,20 – 40) NTU Metoda nefelometryczna","methodology_en":"Turbidity Range: (0,20 – 40) NTU Nephelometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Mętność Zakres: (0,20 – 40) NTU Metoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Mętność Zakres: (0,20 – 40) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda Metnosc Zakres: (0,20 – 40) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Turbidity Range: (0,20 – 40) NTU Nephelometric method PN-EN ISO 7027-1:2016-09","search_zh":"水 PN-EN ISO 7027-1:2016-09","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a24","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Barwa Zakres: (5 – 70) mg/l Pt Metoda wizualna","methodology_en":"Colour Range: (5 – 70) mg/l Pt Visual method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Barwa Zakres: (5 – 70) mg/l Pt Metoda wizualna","reference":"PN-EN ISO 7887:2012","norm_bases":["PN-EN ISO 7887:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Barwa Zakres: (5 – 70) mg/l Pt Metoda wizualna PN-EN ISO 7887:2012 Woda Barwa Zakres: (5 – 70) mg/l Pt Metoda wizualna PN-EN ISO 7887:2012","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Colour Range: (5 – 70) mg/l Pt Visual method PN-EN ISO 7887:2012","methodology_zh":"色度 范围：(5 – 70) mg/l Pt 目视法","search_zh":"水 色度 范围：(5 – 70) mg/l Pt 目视法 PN-EN ISO 7887:2012","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a25","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"pH Zakres: 4,0 – 10,0 Metoda potencjometryczna","methodology_en":"pH Range: 4,0 – 10,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 4,0 – 10,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda pH Zakres: 4,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Woda pH Zakres: 4,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water pH Range: 4,0 – 10,0 Potentiometric method PN-EN ISO 10523:2012","search_zh":"水 pH 范围：4,0 – 10,0 电位法 PN-EN ISO 10523:2012","test_object_zh":"水","methodology_zh":"pH 范围：4,0 – 10,0 电位法"},{"_id":"6a5a55fa9af9f73f38252a26","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Przewodność elektryczna właściwa Zakres: (84 – 13 000) µS/cm Metoda konduktometryczna","methodology_en":"Electrical conductivity Range: (84 – 13 000) µS/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (84 – 13 000) µS/cm Metoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Przewodność elektryczna właściwa Zakres: (84 – 13 000) µS/cm Metoda konduktometryczna PN-EN 27888:1999 Woda Przewodnosc elektryczna wlasciwa Zakres: (84 – 13 000) µS/cm Metoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Electrical conductivity Range: (84 – 13 000) µS/cm Conductometric method PN-EN 27888:1999","search_zh":"水 PN-EN 27888:1999","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a27","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (20 – 600) mg/l CaCO 3 (1,1 – 33,6) on Metoda miareczkowa","methodology_en":"Total calcium and magnesium content (total hardness) Range: (20 – 600) mg/l CaCO 3 (1,1 – 33,6) on Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (20 – 600) mg/l CaCO 3 (1,1 – 33,6) on Metoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (20 – 600) mg/l CaCO 3 (1,1 – 33,6) on Metoda miareczkowa PN-ISO 6059:1999 Woda Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna) Zakres: (20 – 600) mg/l CaCO 3 (1,1 – 33,6) on Metoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Total calcium and magnesium content (total hardness) Range: (20 – 600) mg/l CaCO 3 (1,1 – 33,6) on Titrimetric method PN-ISO 6059:1999","search_zh":"水 PN-ISO 6059:1999","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a28","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie anionów Zakres: chlorany (0,05 – 2,00) mg/l chloryny (0,05 – 2,00) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Σ chloranów i chlorynów (z obliczeń)","methodology_en":"Anion concentrations Range: chlorates (0,05 – 2,00) mg/l chlorites (0,05 – 2,00) mg/l Ion chromatography with conductometric detection (IC-CD) Σ of chlorates and chlorites (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie anionów Zakres: chlorany (0,05 – 2,00) mg/l chloryny (0,05 – 2,00) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Σ chloranów i chlorynów (z obliczeń)","reference":"PN-EN ISO 10304-4:2022-08","norm_bases":["PN-EN ISO 10304-4:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie anionów Zakres: chlorany (0,05 – 2,00) mg/l chloryny (0,05 – 2,00) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Σ chloranów i chlorynów (z obliczeń) PN-EN ISO 10304-4:2022-08 Woda Stezenie anionow Zakres: chlorany (0,05 – 2,00) mg/l chloryny (0,05 – 2,00) mg/l Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Σ chloranow i chlorynow (z obliczen) PN-EN ISO 10304-4:2022-08","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Anion concentrations Range: chlorates (0,05 – 2,00) mg/l chlorites (0,05 – 2,00) mg/l Ion chromatography with conductometric detection (IC-CD) Σ of chlorates and chlorites (calculated) PN-EN ISO 10304-4:2022-08","search_zh":"水 PN-EN ISO 10304-4:2022-08","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a29","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie bromianów Zakres: (0,0030 – 0,0200) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","methodology_en":"Bromate concentration Range: (0,0030 – 0,0200) mg/l Ion chromatography with conductometric detection (IC-CD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie bromianów Zakres: (0,0030 – 0,0200) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 15061:2003","norm_bases":["PN-EN ISO 15061:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie bromianów Zakres: (0,0030 – 0,0200) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 15061:2003 Woda Stezenie bromianow Zakres: (0,0030 – 0,0200) mg/l Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 15061:2003","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Bromate concentration Range: (0,0030 – 0,0200) mg/l Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 15061:2003","search_zh":"水 PN-EN ISO 15061:2003","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a2a","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie lotnych związków organicznych Zakres: benzen (0,10 – 1,5) μg/l trichloroeten (1,0 – 12,0) μg/l tetrachloroeten (1,0 – 12,0) μg/l Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją fotojonizacyjną (P&T-GC-PID) Σ trichloroetenu i tetrachloroetenu (z obliczeń)","methodology_en":"Volatile organic compounds concentration Range: benzene (0,10 – 1,5) μg/l trichloroethene (1,0 – 12,0) μg/l tetrachloroethene (1,0 – 12,0) μg/l Gas chromatography with purge and trap technique (Purge&Trap) and photoionisation detection (P&T-GC-PID) Σ of trichloroethene and tetrachloroethene (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie lotnych związków organicznych Zakres: benzen (0,10 – 1,5) μg/l trichloroeten (1,0 – 12,0) μg/l tetrachloroeten (1,0 – 12,0) μg/l Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją fotojonizacyjną (P&T-GC-PID) Σ trichloroetenu i tetrachloroetenu (z obliczeń)","reference":"PB/19 wydanie 4 z dnia 15.11.2018 r.","norm_bases":["PB/19 wydanie 4 z dnia 15.11.2018 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie lotnych związków organicznych Zakres: benzen (0,10 – 1,5) μg/l trichloroeten (1,0 – 12,0) μg/l tetrachloroeten (1,0 – 12,0) μg/l Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją fotojonizacyjną (P&T-GC-PID) Σ trichloroetenu i tetrachloroetenu (z obliczeń) PB/19 wydanie 4 z dnia 15.11.2018 r. Woda Stezenie lotnych zwiazkow organicznych Zakres: benzen (0,10 – 1,5) μg/l trichloroeten (1,0 – 12,0) μg/l tetrachloroeten (1,0 – 12,0) μg/l Metoda chromatografii gazowej z technika wylapywania i wyplukiwania (Purge&Trap) i detekcja fotojonizacyjna (P&T-GC-PID) Σ trichloroetenu i tetrachloroetenu (z obliczen) PB/19 wydanie 4 z dnia 15.11.2018 r.","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Volatile organic compounds concentration Range: benzene (0,10 – 1,5) μg/l trichloroethene (1,0 – 12,0) μg/l tetrachloroethene (1,0 – 12,0) μg/l Gas chromatography with purge and trap technique (Purge&Trap) and photoionisation detection (P&T-GC-PID) Σ of trichloroethene and tetrachloroethene (calculated) PB/19 wydanie 4 z dnia 15.11.2018 r.","search_zh":"水 PB/19 wydanie 4 z dnia 15.11.2018 r.","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a2b","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie chloru wolnego Zakres: (0,05 – 2,0) mg/l Metoda spektrofotometryczna","methodology_en":"Free chlorine concentration Range: (0,05 – 2,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chloru wolnego Zakres: (0,05 – 2,0) mg/l Metoda spektrofotometryczna","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie chloru wolnego Zakres: (0,05 – 2,0) mg/l Metoda spektrofotometryczna PN-EN ISO 7393-2:2018-04 Woda Stezenie chloru wolnego Zakres: (0,05 – 2,0) mg/l Metoda spektrofotometryczna PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Free chlorine concentration Range: (0,05 – 2,0) mg/l Spectrophotometric method PN-EN ISO 7393-2:2018-04","search_zh":"水 PN-EN ISO 7393-2:2018-04","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a2c","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie chloru całkowitego Zakres: (0,06 – 2,0) mg/l Metoda spektrofotometryczna Stężenie chloru związanego / chloramin (z obliczeń)","methodology_en":"Total chlorine concentration Range: (0,06 – 2,0) mg/l Spectrophotometric method Combined chlorine / chloramine concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chloru całkowitego Zakres: (0,06 – 2,0) mg/l Metoda spektrofotometryczna Stężenie chloru związanego / chloramin (z obliczeń)","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie chloru całkowitego Zakres: (0,06 – 2,0) mg/l Metoda spektrofotometryczna Stężenie chloru związanego / chloramin (z obliczeń) PN-EN ISO 7393-2:2018-04 Woda Stezenie chloru calkowitego Zakres: (0,06 – 2,0) mg/l Metoda spektrofotometryczna Stezenie chloru zwiazanego / chloramin (z obliczen) PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Total chlorine concentration Range: (0,06 – 2,0) mg/l Spectrophotometric method Combined chlorine / chloramine concentration (calculated) PN-EN ISO 7393-2:2018-04","search_zh":"水 PN-EN ISO 7393-2:2018-04","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a2d","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie ozonu zakres: (0,03 – 0,25) mg/l Metoda spektrofotometryczna","methodology_en":"Ozone concentration range: (0,03 – 0,25) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie ozonu zakres: (0,03 – 0,25) mg/l Metoda spektrofotometryczna","reference":"PB/43 wyd. 2 z dnia 20.09.2018 na podstawie metody HACH 8311","norm_bases":["PB/43 wyd. 2 z dnia 20.09.2018 na podstawie metody HACH 8311"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie ozonu zakres: (0,03 – 0,25) mg/l Metoda spektrofotometryczna PB/43 wyd. 2 z dnia 20.09.2018 na podstawie metody HACH 8311 Woda Stezenie ozonu zakres: (0,03 – 0,25) mg/l Metoda spektrofotometryczna PB/43 wyd. 2 z dnia 20.09.2018 na podstawie metody HACH 8311","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Ozone concentration range: (0,03 – 0,25) mg/l Spectrophotometric method PB/43 wyd. 2 z dnia 20.09.2018 na podstawie metody HACH 8311","search_zh":"水 PB/43 wyd. 2 z dnia 20.09.2018 na podstawie metody HACH 8311","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a2e","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie cyjanków ogólnych Zakres: (5,0 – 50,0) µg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","methodology_en":"Total cyanide concentration Range: (5,0 – 50,0) µg/l Continuous flow analysis method (CFA) with spectrophotometric detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie cyjanków ogólnych Zakres: (5,0 – 50,0) µg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 14403-2:2012","norm_bases":["PN-EN ISO 14403-2:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie cyjanków ogólnych Zakres: (5,0 – 50,0) µg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 14403-2:2012 Woda Stezenie cyjankow ogolnych Zakres: (5,0 – 50,0) µg/l Metoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 14403-2:2012","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Total cyanide concentration Range: (5,0 – 50,0) µg/l Continuous flow analysis method (CFA) with spectrophotometric detection PN-EN ISO 14403-2:2012","search_zh":"水 PN-EN ISO 14403-2:2012","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a2f","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie jonu amonowego Zakres: (0,030 – 1,00) mg/l Metoda ciągłej analizy przepływowej (CFA) detekcją spektrofotometryczną","methodology_en":"Ammonium ion concentration Range: (0,030 – 1,00) mg/l Continuous flow analysis (CFA) method with spectrophotometric detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego Zakres: (0,030 – 1,00) mg/l Metoda ciągłej analizy przepływowej (CFA) detekcją spektrofotometryczną","reference":"PN-EN ISO 11732:2007","norm_bases":["PN-EN ISO 11732:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie jonu amonowego Zakres: (0,030 – 1,00) mg/l Metoda ciągłej analizy przepływowej (CFA) detekcją spektrofotometryczną PN-EN ISO 11732:2007 Woda Stezenie jonu amonowego Zakres: (0,030 – 1,00) mg/l Metoda ciaglej analizy przeplywowej (CFA) detekcja spektrofotometryczna PN-EN ISO 11732:2007","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Ammonium ion concentration Range: (0,030 – 1,00) mg/l Continuous flow analysis (CFA) method with spectrophotometric detection PN-EN ISO 11732:2007","search_zh":"水 PN-EN ISO 11732:2007","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a30","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie rtęci Zakres: (0,10 – 10,0) µg/l Metoda atomowej spektrometrii fluorescencyjnej (AFS)","methodology_en":"Mercury concentration Range: (0,10 – 10,0) µg/l Atomic fluorescence spectrometry method (AFS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie rtęci Zakres: (0,10 – 10,0) µg/l Metoda atomowej spektrometrii fluorescencyjnej (AFS)","reference":"PN-EN ISO 17852:2009","norm_bases":["PN-EN ISO 17852:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie rtęci Zakres: (0,10 – 10,0) µg/l Metoda atomowej spektrometrii fluorescencyjnej (AFS) PN-EN ISO 17852:2009 Woda Stezenie rteci Zakres: (0,10 – 10,0) µg/l Metoda atomowej spektrometrii fluorescencyjnej (AFS) PN-EN ISO 17852:2009","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Mercury concentration Range: (0,10 – 10,0) µg/l Atomic fluorescence spectrometry method (AFS) PN-EN ISO 17852:2009","search_zh":"水 PN-EN ISO 17852:2009","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a31","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie chromu (VI) Zakres: (0,010 – 1,0) mg/l Metoda ciągłej analizy przepływowej (CFA) detekcją spektrofotometryczną","methodology_en":"Chromium (VI) concentration Range: (0,010 – 1,0) mg/l Continuous flow analysis (CFA) method with spectrophotometric detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chromu (VI) Zakres: (0,010 – 1,0) mg/l Metoda ciągłej analizy przepływowej (CFA) detekcją spektrofotometryczną","reference":"PN-EN ISO 23913:2009","norm_bases":["PN-EN ISO 23913:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie chromu (VI) Zakres: (0,010 – 1,0) mg/l Metoda ciągłej analizy przepływowej (CFA) detekcją spektrofotometryczną PN-EN ISO 23913:2009 Woda, scieki Stezenie chromu (VI) Zakres: (0,010 – 1,0) mg/l Metoda ciaglej analizy przeplywowej (CFA) detekcja spektrofotometryczna PN-EN ISO 23913:2009","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Chromium (VI) concentration Range: (0,010 – 1,0) mg/l Continuous flow analysis (CFA) method with spectrophotometric detection PN-EN ISO 23913:2009","search_zh":"水、废水 PN-EN ISO 23913:2009","test_object_zh":"水、废水"},{"_id":"6a5a55fa9af9f73f38252a32","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie siarczków Zakres: (0,03 – 0,75) mg/l Metoda ciągłej analizy przepływowej (CFA) detekcją spektrofotometryczną","methodology_en":"Sulphide concentration Range: (0,03 – 0,75) mg/l Continuous flow analysis (CFA) method with spectrophotometric detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie siarczków Zakres: (0,03 – 0,75) mg/l Metoda ciągłej analizy przepływowej (CFA) detekcją spektrofotometryczną","reference":"PB/15 wydanie 1 z dnia 10.10.2022 r. na podstawie aplikacji Metoda nr A-096-20 Rev.0 do analizatora AA500","norm_bases":["PB/15 wydanie 1 z dnia 10.10.2022 r. na podstawie aplikacji Metoda nr A-096-20 Rev.0 do analizatora AA500"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie siarczków Zakres: (0,03 – 0,75) mg/l Metoda ciągłej analizy przepływowej (CFA) detekcją spektrofotometryczną PB/15 wydanie 1 z dnia 10.10.2022 r. na podstawie aplikacji Metoda nr A-096-20 Rev.0 do analizatora AA500 Woda, scieki Stezenie siarczkow Zakres: (0,03 – 0,75) mg/l Metoda ciaglej analizy przeplywowej (CFA) detekcja spektrofotometryczna PB/15 wydanie 1 z dnia 10.10.2022 r. na podstawie aplikacji Metoda nr A-096-20 Rev.0 do analizatora AA500","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Sulphide concentration Range: (0,03 – 0,75) mg/l Continuous flow analysis (CFA) method with spectrophotometric detection PB/15 wydanie 1 z dnia 10.10.2022 r. na podstawie aplikacji Metoda nr A-096-20 Rev.0 do analizatora AA500","search_zh":"水、废水 PB/15 wydanie 1 z dnia 10.10.2022 r. na podstawie aplikacji Metoda nr A-096-20 Rev.0 do analizatora AA500","test_object_zh":"水、废水"},{"_id":"6a5a55fa9af9f73f38252a33","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie cyjanków wolnych Zakres: (0,005 – 0,100) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną Stężenie cyjanków związanych (z obliczeń)","methodology_en":"Free cyanide concentration Range: (0,005 – 0,100) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection Bound cyanide concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie cyjanków wolnych Zakres: (0,005 – 0,100) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną Stężenie cyjanków związanych (z obliczeń)","reference":"PN-EN ISO 14403-2:2012","norm_bases":["PN-EN ISO 14403-2:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie cyjanków wolnych Zakres: (0,005 – 0,100) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną Stężenie cyjanków związanych (z obliczeń) PN-EN ISO 14403-2:2012 Woda, scieki Stezenie cyjankow wolnych Zakres: (0,005 – 0,100) mg/l Metoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna Stezenie cyjankow zwiazanych (z obliczen) PN-EN ISO 14403-2:2012","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Free cyanide concentration Range: (0,005 – 0,100) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection Bound cyanide concentration (calculated) PN-EN ISO 14403-2:2012","search_zh":"水、废水 PN-EN ISO 14403-2:2012","test_object_zh":"水、废水"},{"_id":"6a5a55fa9af9f73f38252a34","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie rtęci Zakres: (0,10 – 10,0) µg/l Metoda atomowej spektrometrii fluorescencyjnej (AFS)","methodology_en":"Mercury concentration Range: (0,10 – 10,0) µg/l Atomic fluorescence spectrometry method (AFS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie rtęci Zakres: (0,10 – 10,0) µg/l Metoda atomowej spektrometrii fluorescencyjnej (AFS)","reference":"PN-EN ISO 17852:2009","norm_bases":["PN-EN ISO 17852:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie rtęci Zakres: (0,10 – 10,0) µg/l Metoda atomowej spektrometrii fluorescencyjnej (AFS) PN-EN ISO 17852:2009 Scieki Stezenie rteci Zakres: (0,10 – 10,0) µg/l Metoda atomowej spektrometrii fluorescencyjnej (AFS) PN-EN ISO 17852:2009","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Mercury concentration Range: (0,10 – 10,0) µg/l Atomic fluorescence spectrometry method (AFS) PN-EN ISO 17852:2009","search_zh":"污水 PN-EN ISO 17852:2009","test_object_zh":"污水"},{"_id":"6a5a55fa9af9f73f38252a35","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie cyjanków ogólnych Zakres: (0,005 – 5,0) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","methodology_en":"Total cyanide concentration Range: (0,005 – 5,0) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie cyjanków ogólnych Zakres: (0,005 – 5,0) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 14403-2:2012","norm_bases":["PN-EN ISO 14403-2:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie cyjanków ogólnych Zakres: (0,005 – 5,0) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 14403-2:2012 Scieki Stezenie cyjankow ogolnych Zakres: (0,005 – 5,0) mg/l Metoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 14403-2:2012","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Total cyanide concentration Range: (0,005 – 5,0) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection PN-EN ISO 14403-2:2012","search_zh":"污水 PN-EN ISO 14403-2:2012","test_object_zh":"污水"},{"_id":"6a5a55fa9af9f73f38252a36","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie chlorowcopochodnych Zakres: Heksachlorobutadien (0,5 – 5,0) μg/l Chloroform (1,0 – 150,0) μg/l Tertachloroetylen (1,0 – 150,0) μg/l Trichloroetylen (1,0 – 150,0) μg/ Tertachlorometan (0,5 – 5,0) μg/l 1,2- dichloroetan (0,5 – 5,0) μg/l Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją wychwytu elektronów (HS-GC-ECD)","methodology_en":"Concentration of halogenated derivatives Range: Hexachlorobutadiene (0,5 – 5,0) μg/l Chloroform (1,0 – 150,0) μg/l Tetrachloroethylene (1,0 – 150,0) μg/l Trichloroethylene (1,0 – 150,0) μg/ Tetrachloromethane (0,5 – 5,0) μg/l 1,2- dichloroethane (0,5 – 5,0) μg/l Headspace gas chromatography with electron capture detection (HS-GC-ECD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorowcopochodnych Zakres: Heksachlorobutadien (0,5 – 5,0) μg/l Chloroform (1,0 – 150,0) μg/l Tertachloroetylen (1,0 – 150,0) μg/l Trichloroetylen (1,0 – 150,0) μg/ Tertachlorometan (0,5 – 5,0) μg/l 1,2- dichloroetan (0,5 – 5,0) μg/l Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją wychwytu elektronów (HS-GC-ECD)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie chlorowcopochodnych Zakres: Heksachlorobutadien (0,5 – 5,0) μg/l Chloroform (1,0 – 150,0) μg/l Tertachloroetylen (1,0 – 150,0) μg/l Trichloroetylen (1,0 – 150,0) μg/ Tertachlorometan (0,5 – 5,0) μg/l 1,2- dichloroetan (0,5 – 5,0) μg/l Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją wychwytu elektronów (HS-GC-ECD) PN-EN ISO 10301:2002 Scieki Stezenie chlorowcopochodnych Zakres: Heksachlorobutadien (0,5 – 5,0) μg/l Chloroform (1,0 – 150,0) μg/l Tertachloroetylen (1,0 – 150,0) μg/l Trichloroetylen (1,0 – 150,0) μg/ Tertachlorometan (0,5 – 5,0) μg/l 1,2- dichloroetan (0,5 – 5,0) μg/l Metoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja wychwytu elektronow (HS-GC-ECD) PN-EN ISO 10301:2002","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Concentration of halogenated derivatives Range: Hexachlorobutadiene (0,5 – 5,0) μg/l Chloroform (1,0 – 150,0) μg/l Tetrachloroethylene (1,0 – 150,0) μg/l Trichloroethylene (1,0 – 150,0) μg/ Tetrachloromethane (0,5 – 5,0) μg/l 1,2- dichloroethane (0,5 – 5,0) μg/l Headspace gas chromatography with electron capture detection (HS-GC-ECD) PN-EN ISO 10301:2002","search_zh":"污水 PN-EN ISO 10301:2002","test_object_zh":"污水"},{"_id":"6a5a55fa9af9f73f38252a37","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie pestycydów chloroorganicznych Zakres: lindan (0,010 – 0,50) μg/l heptachlor (0,010 – 0,50) μg/l aldryna (0,010 – 0,50) μg/l izodryna (0,010 – 0,50) μg/l epoksyd heptachloru (0,010 – 0,50) μg/l dieldryna (0,010 – 0,50) μg/l endryna (0,010 – 0,50) μg/l metoksychlor (0,010 – 0,50) μg/l Metoda chromatografii gazowej z detekcją spektrometrii mas (GC-MS/MS) Σ pestycydów (z obliczeń)","methodology_en":"Organochlorine pesticide concentration Range: lindane (0,010 – 0,50) μg/l heptachlor (0,010 – 0,50) μg/l aldrin (0,010 – 0,50) μg/l isodrin (0,010 – 0,50) μg/l heptachlor epoxide (0,010 – 0,50) μg/l dieldrin (0,010 – 0,50) μg/l endrin (0,010 – 0,50) μg/l methoxychlor (0,010 – 0,50) μg/l Gas chromatography with mass spectrometry detection (GC-MS/MS) Σ of pesticides (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pestycydów chloroorganicznych Zakres: lindan (0,010 – 0,50) μg/l heptachlor (0,010 – 0,50) μg/l aldryna (0,010 – 0,50) μg/l izodryna (0,010 – 0,50) μg/l epoksyd heptachloru (0,010 – 0,50) μg/l dieldryna (0,010 – 0,50) μg/l endryna (0,010 – 0,50) μg/l metoksychlor (0,010 – 0,50) μg/l Metoda chromatografii gazowej z detekcją spektrometrii mas (GC-MS/MS) Σ pestycydów (z obliczeń)","reference":"PB/10 wydanie 1 z dnia 08.10.2024","norm_bases":["PB/10 wydanie 1 z dnia 08.10.2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie pestycydów chloroorganicznych Zakres: lindan (0,010 – 0,50) μg/l heptachlor (0,010 – 0,50) μg/l aldryna (0,010 – 0,50) μg/l izodryna (0,010 – 0,50) μg/l epoksyd heptachloru (0,010 – 0,50) μg/l dieldryna (0,010 – 0,50) μg/l endryna (0,010 – 0,50) μg/l metoksychlor (0,010 – 0,50) μg/l Metoda chromatografii gazowej z detekcją spektrometrii mas (GC-MS/MS) Σ pestycydów (z obliczeń) PB/10 wydanie 1 z dnia 08.10.2024 Woda, woda do spozycia przez ludzi Stezenie pestycydow chloroorganicznych Zakres: lindan (0,010 – 0,50) μg/l heptachlor (0,010 – 0,50) μg/l aldryna (0,010 – 0,50) μg/l izodryna (0,010 – 0,50) μg/l epoksyd heptachloru (0,010 – 0,50) μg/l dieldryna (0,010 – 0,50) μg/l endryna (0,010 – 0,50) μg/l metoksychlor (0,010 – 0,50) μg/l Metoda chromatografii gazowej z detekcja spektrometrii mas (GC-MS/MS) Σ pestycydow (z obliczen) PB/10 wydanie 1 z dnia 08.10.2024","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Organochlorine pesticide concentration Range: lindane (0,010 – 0,50) μg/l heptachlor (0,010 – 0,50) μg/l aldrin (0,010 – 0,50) μg/l isodrin (0,010 – 0,50) μg/l heptachlor epoxide (0,010 – 0,50) μg/l dieldrin (0,010 – 0,50) μg/l endrin (0,010 – 0,50) μg/l methoxychlor (0,010 – 0,50) μg/l Gas chromatography with mass spectrometry detection (GC-MS/MS) Σ of pesticides (calculated) PB/10 wydanie 1 z dnia 08.10.2024","search_zh":"水、生活饮用水 PB/10 wydanie 1 z dnia 08.10.2024","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55fa9af9f73f38252a38","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie pierwiastków Zakres: antymon (1,00 – 100,0) ug/l arsen (1,00 – 100,0) ug/l bor (5,00 – 5000,0) ug/l chrom (5,00 – 5000,0) ug/l glin (5,00 – 5000,0) ug/l kadm (1,00 – 100,0) ug/l miedź (5,00 – 5000,0) ug/l mangan (5,00 – 5000,0) ug/l nikiel (5,00 – 5000,0) ug/l ołów (1,00 – 100,0) ug/l srebro (1,00 – 100,0) ug/l selen (1,00 – 100,0) ug/l uran (5,00 – 5000,0) ug/l żelazo (5,00 – 5000,0) ug/l Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","methodology_en":"Element concentrations Range: antimony (1,00 – 100,0) ug/l arsenic (1,00 – 100,0) ug/l boron (5,00 – 5000,0) ug/l chromium (5,00 – 5000,0) ug/l aluminium (5,00 – 5000,0) ug/l cadmium (1,00 – 100,0) ug/l copper (5,00 – 5000,0) ug/l manganese (5,00 – 5000,0) ug/l nickel (5,00 – 5000,0) ug/l lead (1,00 – 100,0) ug/l silver (1,00 – 100,0) ug/l selenium (1,00 – 100,0) ug/l uranium (5,00 – 5000,0) ug/l iron (5,00 – 5000,0) ug/l Inductively coupled plasma mass spectrometry (ICP-MS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pierwiastków Zakres: antymon (1,00 – 100,0) ug/l arsen (1,00 – 100,0) ug/l bor (5,00 – 5000,0) ug/l chrom (5,00 – 5000,0) ug/l glin (5,00 – 5000,0) ug/l kadm (1,00 – 100,0) ug/l miedź (5,00 – 5000,0) ug/l mangan (5,00 – 5000,0) ug/l nikiel (5,00 – 5000,0) ug/l ołów (1,00 – 100,0) ug/l srebro (1,00 – 100,0) ug/l selen (1,00 – 100,0) ug/l uran (5,00 – 5000,0) ug/l żelazo (5,00 – 5000,0) ug/l Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN ISO 17294-2: 2024-04","norm_bases":["PN-EN ISO 17294-2: 2024-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie pierwiastków Zakres: antymon (1,00 – 100,0) ug/l arsen (1,00 – 100,0) ug/l bor (5,00 – 5000,0) ug/l chrom (5,00 – 5000,0) ug/l glin (5,00 – 5000,0) ug/l kadm (1,00 – 100,0) ug/l miedź (5,00 – 5000,0) ug/l mangan (5,00 – 5000,0) ug/l nikiel (5,00 – 5000,0) ug/l ołów (1,00 – 100,0) ug/l srebro (1,00 – 100,0) ug/l selen (1,00 – 100,0) ug/l uran (5,00 – 5000,0) ug/l żelazo (5,00 – 5000,0) ug/l Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN ISO 17294-2: 2024-04 Woda do spozycia przez ludzi Stezenie pierwiastkow Zakres: antymon (1,00 – 100,0) ug/l arsen (1,00 – 100,0) ug/l bor (5,00 – 5000,0) ug/l chrom (5,00 – 5000,0) ug/l glin (5,00 – 5000,0) ug/l kadm (1,00 – 100,0) ug/l miedz (5,00 – 5000,0) ug/l mangan (5,00 – 5000,0) ug/l nikiel (5,00 – 5000,0) ug/l olow (1,00 – 100,0) ug/l srebro (1,00 – 100,0) ug/l selen (1,00 – 100,0) ug/l uran (5,00 – 5000,0) ug/l zelazo (5,00 – 5000,0) ug/l Metoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN ISO 17294-2: 2024-04","categories":["water","materials"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Element concentrations Range: antimony (1,00 – 100,0) ug/l arsenic (1,00 – 100,0) ug/l boron (5,00 – 5000,0) ug/l chromium (5,00 – 5000,0) ug/l aluminium (5,00 – 5000,0) ug/l cadmium (1,00 – 100,0) ug/l copper (5,00 – 5000,0) ug/l manganese (5,00 – 5000,0) ug/l nickel (5,00 – 5000,0) ug/l lead (1,00 – 100,0) ug/l silver (1,00 – 100,0) ug/l selenium (1,00 – 100,0) ug/l uranium (5,00 – 5000,0) ug/l iron (5,00 – 5000,0) ug/l Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN ISO 17294-2: 2024-04","search_zh":"生活饮用水 PN-EN ISO 17294-2: 2024-04","test_object_zh":"生活饮用水"},{"_id":"6a5a55fa9af9f73f38252a39","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda E","test_object_en":"Water E","methodology":"Stężenie pestycydów chloroorganicznych Metoda chromatografii gazowej z detekcją spektrometrii mas (GC-MS) Σ pestycydów (z obliczeń)","methodology_en":"Organochlorine pesticide concentration Gas chromatography with mass spectrometry detection (GC-MS) Σ of pesticides (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pestycydów chloroorganicznych Metoda chromatografii gazowej z detekcją spektrometrii mas (GC-MS) Σ pestycydów (z obliczeń)","reference":"PB/36","norm_bases":["PB/36"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda E Stężenie pestycydów chloroorganicznych Metoda chromatografii gazowej z detekcją spektrometrii mas (GC-MS) Σ pestycydów (z obliczeń) PB/36 Woda E Stezenie pestycydow chloroorganicznych Metoda chromatografii gazowej z detekcja spektrometrii mas (GC-MS) Σ pestycydow (z obliczen) PB/36","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water E Organochlorine pesticide concentration Gas chromatography with mass spectrometry detection (GC-MS) Σ of pesticides (calculated) PB/36","search_zh":"水 E PB/36","test_object_zh":"水 E"},{"_id":"6a5a55fa9af9f73f38252a3a","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda E","test_object_en":"Water E","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA) Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) Σ WWA (z obliczeń)","methodology_en":"Concentration of polycyclic aromatic hydrocarbons (PAH) High performance liquid chromatography method with fluorescence detection (HPLC-FLD) Σ PAH (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA) Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) Σ WWA (z obliczeń)","reference":"PB/49","norm_bases":["PB/49"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda E Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA) Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) Σ WWA (z obliczeń) PB/49 Woda E Stezenie wielopierscieniowych weglowodorow aromatycznych (WWA) Metoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) Σ WWA (z obliczen) PB/49","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water E Concentration of polycyclic aromatic hydrocarbons (PAH) High performance liquid chromatography method with fluorescence detection (HPLC-FLD) Σ PAH (calculated) PB/49","search_zh":"水 E PB/49","test_object_zh":"水 E"},{"_id":"6a5a55fa9af9f73f38252a3b","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda E","test_object_en":"Water E","methodology":"Stężenie anionów Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","methodology_en":"Anion concentrations Ion chromatography with conductometric detection (IC-CD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie anionów Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009 +AC:2012","norm_bases":["PN-EN ISO 10304-1:2009 +AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda E Stężenie anionów Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 +AC:2012 Woda E Stezenie anionow Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009 +AC:2012","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water E Anion concentrations Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009 +AC:2012","search_zh":"水 E PN-EN ISO 10304-1:2009 +AC:2012","test_object_zh":"水 E"},{"_id":"6a5a55fa9af9f73f38252a3c","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda E","test_object_en":"Water E","methodology":"Stężenie chlorowcopochodnych Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją wychwytu elektronów (HS-GC-ECD) Σ THM (z obliczeń) Σ trichloroetenu i tetrachloroetenu (z obliczeń)","methodology_en":"Concentration of halogenated derivatives Headspace gas chromatography with electron capture detection (HS-GC-ECD) Σ THM (calculated) Σ of trichloroethene and tetrachloroethene (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorowcopochodnych Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją wychwytu elektronów (HS-GC-ECD) Σ THM (z obliczeń) Σ trichloroetenu i tetrachloroetenu (z obliczeń)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda E Stężenie chlorowcopochodnych Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją wychwytu elektronów (HS-GC-ECD) Σ THM (z obliczeń) Σ trichloroetenu i tetrachloroetenu (z obliczeń) PN-EN ISO 10301:2002 Woda E Stezenie chlorowcopochodnych Metoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja wychwytu elektronow (HS-GC-ECD) Σ THM (z obliczen) Σ trichloroetenu i tetrachloroetenu (z obliczen) PN-EN ISO 10301:2002","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water E Concentration of halogenated derivatives Headspace gas chromatography with electron capture detection (HS-GC-ECD) Σ THM (calculated) Σ of trichloroethene and tetrachloroethene (calculated) PN-EN ISO 10301:2002","search_zh":"水 E PN-EN ISO 10301:2002","test_object_zh":"水 E"},{"_id":"6a5a55fa9af9f73f38252a3d","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi E","test_object_en":"Water intended for human consumption E","methodology":"Stężenie metali Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","methodology_en":"Metal concentrations Inductively coupled plasma optical emission spectrometry (ICP-OES)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie metali Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi E Stężenie metali Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda do spozycia przez ludzi E Stezenie metali Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["materials","water"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption E Metal concentrations Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009","search_zh":"生活饮用水 E PN-EN ISO 11885:2009","test_object_zh":"生活饮用水 E"},{"_id":"6a5a55fa9af9f73f38252a3e","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda E, ścieki E","test_object_en":"Water E, wastewater E","methodology":"Stężenie metali Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","methodology_en":"Metal concentrations Inductively coupled plasma optical emission spectrometry (ICP-OES)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie metali Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda E, ścieki E Stężenie metali Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda E, scieki E Stezenie metali Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water","materials"],"row_index":28,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water E, wastewater E Metal concentrations Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009"},{"_id":"6a5a55fa9af9f73f38252a3f","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.3","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.3 Woda Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem pkt 4.4.3","categories":["water","microbiology"],"row_index":29,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.3","methodology_zh":"微生物检测用样品采集","search_zh":"水 微生物检测用样品采集 PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.3","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a40","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","test_object_en":"Water (including swimming pool water)","methodology":"Ogólna liczba mikroorganizmów w 36°C Metoda płytkowa (posiew wgłębny)","methodology_en":"Total viable count at 36°C Plate method (pour plate)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 36°C Metoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach) Ogólna liczba mikroorganizmów w 36°C Metoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda (w tym woda na plywalniach) Ogolna liczba mikroorganizmow w 36°C Metoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":30,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water (including swimming pool water) Total viable count at 36°C Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"水（含游泳池水） 36°C 微生物总数 平板法（倾注平板） PN-EN ISO 6222:2004","test_object_zh":"水（含游泳池水）","methodology_zh":"36°C 微生物总数 平板法（倾注平板）"},{"_id":"6a5a55fa9af9f73f38252a41","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","test_object_en":"Water (including swimming pool water)","methodology":"Liczba Escherichia coli Metoda filtracji membranowej","methodology_en":"Escherichia coli count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba Escherichia coli Metoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach) Liczba Escherichia coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda (w tym woda na plywalniach) Liczba Escherichia coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":31,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water (including swimming pool water) Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数 膜过滤法","search_zh":"水（含游泳池水） 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","test_object_zh":"水（含游泳池水）"},{"_id":"6a5a55fa9af9f73f38252a42","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Ogólna liczba mikroorganizmów w 22°C Metoda płytkowa (posiew wgłębny)","methodology_en":"Total viable count at 22°C Plate method (pour plate)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 22°C Metoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ogólna liczba mikroorganizmów w 22°C Metoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda Ogolna liczba mikroorganizmow w 22°C Metoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":32,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Total viable count at 22°C Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"水 22°C 微生物总数 平板法（倾注平板） PN-EN ISO 6222:2004","test_object_zh":"水","methodology_zh":"22°C 微生物总数 平板法（倾注平板）"},{"_id":"6a5a55fa9af9f73f38252a43","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba bakterii grupy coli Metoda filtracji membranowej","methodology_en":"Coliform bacteria count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli Metoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba bakterii grupy coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda Liczba bakterii grupy coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":33,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","methodology_zh":"大肠菌群计数 膜过滤法","search_zh":"水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a44","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba enterokoków kałowych Metoda filtracji membranowej","methodology_en":"Intestinal enterococci count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba enterokoków kałowych Metoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba enterokoków kałowych Metoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda Liczba enterokokow kalowych Metoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":34,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","search_zh":"水 肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","test_object_zh":"水","methodology_zh":"肠球菌计数 膜过滤法"},{"_id":"6a5a55fa9af9f73f38252a45","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba Clostridium perfringens (łącznie z przetrwalnikami) Metoda filtracji membranowej","methodology_en":"Clostridium perfringens count (including spores) Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba Clostridium perfringens (łącznie z przetrwalnikami) Metoda filtracji membranowej","reference":"Metodyka PZH-ZHK:2006 – część II","norm_bases":["Metodyka PZH-ZHK:2006 – część II"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba Clostridium perfringens (łącznie z przetrwalnikami) Metoda filtracji membranowej Metodyka PZH-ZHK:2006 – część II Woda Liczba Clostridium perfringens (lacznie z przetrwalnikami) Metoda filtracji membranowej Metodyka PZH-ZHK:2006 – czesc II","categories":["water"],"row_index":35,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Clostridium perfringens count (including spores) Membrane filtration method Metodyka PZH-ZHK:2006 – część II","search_zh":"水 产气荚膜梭菌数（含芽孢） 膜过滤法 Metodyka PZH-ZHK:2006 – część II","test_object_zh":"水","methodology_zh":"产气荚膜梭菌数（含芽孢） 膜过滤法"},{"_id":"6a5a55fa9af9f73f38252a46","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba Clostridium perfringens (łącznie z przetrwalnikami) Metoda filtracji membranowej","methodology_en":"Clostridium perfringens count (including spores) Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba Clostridium perfringens (łącznie z przetrwalnikami) Metoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba Clostridium perfringens (łącznie z przetrwalnikami) Metoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda Liczba Clostridium perfringens (lacznie z przetrwalnikami) Metoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":36,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Clostridium perfringens count (including spores) Membrane filtration method PN-EN ISO 14189:2016-10","search_zh":"水 产气荚膜梭菌数（含芽孢） 膜过滤法 PN-EN ISO 14189:2016-10","test_object_zh":"水","methodology_zh":"产气荚膜梭菌数（含芽孢） 膜过滤法"},{"_id":"6a5a55fa9af9f73f38252a47","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli i Escherichia coli Metoda NPL","methodology_en":"Most probable number of coliform bacteria and Escherichia coli MPN method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli i Escherichia coli Metoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Najbardziej prawdopodobna liczba bakterii grupy coli i Escherichia coli Metoda NPL PN-EN ISO 9308-2:2014-06 Woda Najbardziej prawdopodobna liczba bakterii grupy coli i Escherichia coli Metoda NPL PN-EN ISO 9308-2:2014-06","categories":["microbiology","water"],"row_index":37,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Most probable number of coliform bacteria and Escherichia coli MPN method PN-EN ISO 9308-2:2014-06","search_zh":"水 PN-EN ISO 9308-2:2014-06","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a48","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","test_object_en":"Water (including swimming pool water)","methodology":"Liczba bakterii z rodzaju Legionella Matryca A Procedura 5, pożywka A Procedura 7, pożywka C Metoda filtracji membranowej","methodology_en":"Count of bacteria of the genus Legionella Matrix A Procedure 5, medium A Procedure 7, medium C Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba bakterii z rodzaju Legionella Matryca A Procedura 5, pożywka A Procedura 7, pożywka C Metoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 +Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 +Ap1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach) Liczba bakterii z rodzaju Legionella Matryca A Procedura 5, pożywka A Procedura 7, pożywka C Metoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12 Woda (w tym woda na plywalniach) Liczba bakterii z rodzaju Legionella Matryca A Procedura 5, pozywka A Procedura 7, pozywka C Metoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12","categories":["microbiology","water"],"row_index":38,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water (including swimming pool water) Count of bacteria of the genus Legionella Matrix A Procedure 5, medium A Procedure 7, medium C Membrane filtration method PN-EN ISO 11731:2017-08 +Ap1:2019-12","search_zh":"水（含游泳池水） PN-EN ISO 11731:2017-08 +Ap1:2019-12","test_object_zh":"水（含游泳池水）"},{"_id":"6a5a55fa9af9f73f38252a49","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","test_object_en":"Water (including swimming pool water)","methodology":"Liczba Pseudomonas aeruginosa Metoda filtracji membranowej","methodology_en":"Pseudomonas aeruginosa count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba Pseudomonas aeruginosa Metoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach) Liczba Pseudomonas aeruginosa Metoda filtracji membranowej PN-EN ISO 16266:2009 Woda (w tym woda na plywalniach) Liczba Pseudomonas aeruginosa Metoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":39,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water (including swimming pool water) Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","search_zh":"水（含游泳池水） 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","test_object_zh":"水（含游泳池水）","methodology_zh":"铜绿假单胞菌计数 膜过滤法"},{"_id":"6a5a55fa9af9f73f38252a4a","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba progowa zapachu (TON) Zakres: 1 – 64 Metoda pełna parzysta, wybór niewymuszony","methodology_en":"Threshold odour number (TON) Range: 1 – 64 Full paired method, non-forced choice","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba progowa zapachu (TON) Zakres: 1 – 64 Metoda pełna parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba progowa zapachu (TON) Zakres: 1 – 64 Metoda pełna parzysta, wybór niewymuszony PN-EN 1622:2006 Woda Liczba progowa zapachu (TON) Zakres: 1 – 64 Metoda pelna parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":40,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Threshold odour number (TON) Range: 1 – 64 Full paired method, non-forced choice PN-EN 1622:2006","search_zh":"水 PN-EN 1622:2006","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a4b","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba progowa smaku (TFN) Zakres: 1 – 64 Metoda pełna parzysta, wybór niewymuszony","methodology_en":"Threshold flavour number (TFN) Range: 1 – 64 Full paired method, non-forced choice","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba progowa smaku (TFN) Zakres: 1 – 64 Metoda pełna parzysta, wybór niewymuszony","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba progowa smaku (TFN) Zakres: 1 – 64 Metoda pełna parzysta, wybór niewymuszony Woda Liczba progowa smaku (TFN) Zakres: 1 – 64 Metoda pelna parzysta, wybor niewymuszony","categories":["water"],"row_index":41,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Threshold flavour number (TFN) Range: 1 – 64 Full paired method, non-forced choice","search_zh":"水","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a4c","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)","methodology_en":"Sampling for chemical and physical testing (including sensory testing)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)","reference":"PN-ISO 5667-5:2017-10 PN-ISO 5667-4:2017-10 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.3","norm_bases":["PN-ISO 5667-5:2017-10 PN-ISO 5667-4:2017-10 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych) PN-ISO 5667-5:2017-10 PN-ISO 5667-4:2017-10 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.3 Woda Pobieranie probek do badan chemicznych i fizycznych (w tym sensorycznych) PN-ISO 5667-5:2017-10 PN-ISO 5667-4:2017-10 PN-EN ISO 5667-6:2016-12 z wylaczeniem pkt 7.3","categories":["water"],"row_index":42,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Sampling for chemical and physical testing (including sensory testing) PN-ISO 5667-5:2017-10 PN-ISO 5667-4:2017-10 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.3","search_zh":"水 化学和物理检测采样（含感官检测） PN-ISO 5667-5:2017-10 PN-ISO 5667-4:2017-10 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.3","test_object_zh":"水","methodology_zh":"化学和物理检测采样（含感官检测）"},{"_id":"6a5a55fa9af9f73f38252a4d","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Barwa Zakres: (5 – 70) mg/l Pt Metoda wizualna","methodology_en":"Colour Range: (5 – 70) mg/l Pt Visual method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Barwa Zakres: (5 – 70) mg/l Pt Metoda wizualna","reference":"PN-EN ISO 7887:2012 metoda D","norm_bases":["PN-EN ISO 7887:2012 metoda D"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Barwa Zakres: (5 – 70) mg/l Pt Metoda wizualna PN-EN ISO 7887:2012 metoda D Woda Barwa Zakres: (5 – 70) mg/l Pt Metoda wizualna PN-EN ISO 7887:2012 metoda D","categories":["water"],"row_index":43,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Colour Range: (5 – 70) mg/l Pt Visual method PN-EN ISO 7887:2012 metoda D","methodology_zh":"色度 范围：(5 – 70) mg/l Pt 目视法","search_zh":"水 色度 范围：(5 – 70) mg/l Pt 目视法 PN-EN ISO 7887:2012 metoda D","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a4e","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie ogólnego węgla organicznego (OWO) Zakres: (1,0 – 100) mg/l Metoda spektrometrii w zakresie podczerwieni IR","methodology_en":"Total organic carbon (TOC) concentration Range: (1,0 – 100) mg/l Infrared range spectrometry method IR","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie ogólnego węgla organicznego (OWO) Zakres: (1,0 – 100) mg/l Metoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie ogólnego węgla organicznego (OWO) Zakres: (1,0 – 100) mg/l Metoda spektrometrii w zakresie podczerwieni IR PN-EN 1484:1999 Woda Stezenie ogolnego wegla organicznego (OWO) Zakres: (1,0 – 100) mg/l Metoda spektrometrii w zakresie podczerwieni IR PN-EN 1484:1999","categories":["water"],"row_index":44,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Total organic carbon (TOC) concentration Range: (1,0 – 100) mg/l Infrared range spectrometry method IR PN-EN 1484:1999","search_zh":"水 PN-EN 1484:1999","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a4f","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie żelaza Zakres: (0,050 – 1,00) mg/l Metoda spektrofotometryczna","methodology_en":"Iron concentration Range: (0,050 – 1,00) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie żelaza Zakres: (0,050 – 1,00) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 6332:2001 z wyłączeniem pkt 7.3","norm_bases":["PN-ISO 6332:2001 z wyłączeniem pkt 7.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie żelaza Zakres: (0,050 – 1,00) mg/l Metoda spektrofotometryczna PN-ISO 6332:2001 z wyłączeniem pkt 7.3 Woda Stezenie zelaza Zakres: (0,050 – 1,00) mg/l Metoda spektrofotometryczna PN-ISO 6332:2001 z wylaczeniem pkt 7.3","categories":["water"],"row_index":45,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Iron concentration Range: (0,050 – 1,00) mg/l Spectrophotometric method PN-ISO 6332:2001 z wyłączeniem pkt 7.3","search_zh":"水 PN-ISO 6332:2001 z wyłączeniem pkt 7.3","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a50","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie manganu Zakres: (0,015 – 0,50) mg/l Metoda spektrofotometryczna","methodology_en":"Manganese concentration Range: (0,015 – 0,50) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie manganu Zakres: (0,015 – 0,50) mg/l Metoda spektrofotometryczna","reference":"PN-92/C-04590/03","norm_bases":["PN-92/C-04590/03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie manganu Zakres: (0,015 – 0,50) mg/l Metoda spektrofotometryczna PN-92/C-04590/03 Woda Stezenie manganu Zakres: (0,015 – 0,50) mg/l Metoda spektrofotometryczna PN-92/C-04590/03","categories":["water"],"row_index":46,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Manganese concentration Range: (0,015 – 0,50) mg/l Spectrophotometric method PN-92/C-04590/03","search_zh":"水 PN-92/C-04590/03","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a51","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie glinu Zakres: (0,050 – 1,0) mg/l Metoda spektrofotometryczna","methodology_en":"Aluminium concentration Range: (0,050 – 1,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie glinu Zakres: (0,050 – 1,0) mg/l Metoda spektrofotometryczna","reference":"PN-92/C-04605/02","norm_bases":["PN-92/C-04605/02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie glinu Zakres: (0,050 – 1,0) mg/l Metoda spektrofotometryczna PN-92/C-04605/02 Woda Stezenie glinu Zakres: (0,050 – 1,0) mg/l Metoda spektrofotometryczna PN-92/C-04605/02","categories":["water"],"row_index":47,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Aluminium concentration Range: (0,050 – 1,0) mg/l Spectrophotometric method PN-92/C-04605/02","search_zh":"水 PN-92/C-04605/02","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a52","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie jonu amonowego Zakres: (0,05 – 2,0) mg/l Metoda spektrofotometryczna","methodology_en":"Ammonium ion concentration Range: (0,05 – 2,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego Zakres: (0,05 – 2,0) mg/l Metoda spektrofotometryczna","reference":"PN-EN ISO 7150-1:2002","norm_bases":["PN-EN ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie jonu amonowego Zakres: (0,05 – 2,0) mg/l Metoda spektrofotometryczna PN-EN ISO 7150-1:2002 Woda Stezenie jonu amonowego Zakres: (0,05 – 2,0) mg/l Metoda spektrofotometryczna PN-EN ISO 7150-1:2002","categories":["water"],"row_index":48,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Ammonium ion concentration Range: (0,05 – 2,0) mg/l Spectrophotometric method PN-EN ISO 7150-1:2002","search_zh":"水 PN-EN ISO 7150-1:2002","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a53","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie azotu organicznego (z obliczeń)","methodology_en":"Organic nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu organicznego (z obliczeń)","reference":"PB/4/G wydanie 2 z dnia 07.10.2022","norm_bases":["PB/4/G wydanie 2 z dnia 07.10.2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie azotu organicznego (z obliczeń) PB/4/G wydanie 2 z dnia 07.10.2022 Woda Stezenie azotu organicznego (z obliczen) PB/4/G wydanie 2 z dnia 07.10.2022","categories":["water"],"row_index":49,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Organic nitrogen concentration (calculated) PB/4/G wydanie 2 z dnia 07.10.2022","search_zh":"水 有机氮浓度（由计算得出） PB/4/G wydanie 2 z dnia 07.10.2022","test_object_zh":"水","methodology_zh":"有机氮浓度（由计算得出）"},{"_id":"6a5a55fa9af9f73f38252a54","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie azotynów Zakres: (0,04 – 1,00) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrite concentration Range: (0,04 – 1,00) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotynów Zakres: (0,04 – 1,00) mg/l Metoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie azotynów Zakres: (0,04 – 1,00) mg/l Metoda spektrofotometryczna PN-EN 26777:1999 Woda Stezenie azotynow Zakres: (0,04 – 1,00) mg/l Metoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":50,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Nitrite concentration Range: (0,04 – 1,00) mg/l Spectrophotometric method PN-EN 26777:1999","search_zh":"水 PN-EN 26777:1999","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a55","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB/4/G wydanie 2 z dnia 07.10.2022","norm_bases":["PB/4/G wydanie 2 z dnia 07.10.2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie azotu ogólnego (z obliczeń) PB/4/G wydanie 2 z dnia 07.10.2022 Woda Stezenie azotu ogolnego (z obliczen) PB/4/G wydanie 2 z dnia 07.10.2022","categories":["water"],"row_index":51,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Total nitrogen concentration (calculated) PB/4/G wydanie 2 z dnia 07.10.2022","methodology_zh":"总氮浓度（计算值）","search_zh":"水 总氮浓度（计算值） PB/4/G wydanie 2 z dnia 07.10.2022","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a56","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie azotanów Zakres: (1,0 – 50) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrate concentration Range: (1,0 – 50) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotanów Zakres: (1,0 – 50) mg/l Metoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie azotanów Zakres: (1,0 – 50) mg/l Metoda spektrofotometryczna PN-82/C-04576/08 Woda Stezenie azotanow Zakres: (1,0 – 50) mg/l Metoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":52,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Nitrate concentration Range: (1,0 – 50) mg/l Spectrophotometric method PN-82/C-04576/08","search_zh":"水 PN-82/C-04576/08","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a57","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie azotu Kjeldahla Zakres: (1 – 10) mg/l Metoda miareczkowania potencjometrycznego","methodology_en":"Kjeldahl nitrogen concentration Range: (1 – 10) mg/l Potentiometric titration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla Zakres: (1 – 10) mg/l Metoda miareczkowania potencjometrycznego","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie azotu Kjeldahla Zakres: (1 – 10) mg/l Metoda miareczkowania potencjometrycznego PN-EN 25663:2001 Woda Stezenie azotu Kjeldahla Zakres: (1 – 10) mg/l Metoda miareczkowania potencjometrycznego PN-EN 25663:2001","categories":["water"],"row_index":53,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Kjeldahl nitrogen concentration Range: (1 – 10) mg/l Potentiometric titration method PN-EN 25663:2001","search_zh":"水 PN-EN 25663:2001","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a58","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie ozonu Zakres: (0,03 – 0,7) mg/l Metoda spektrofotometryczna","methodology_en":"Ozone concentration Range: (0,03 – 0,7) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie ozonu Zakres: (0,03 – 0,7) mg/l Metoda spektrofotometryczna","reference":"PB/43 wyd. 2 z dnia 20.09.2018 r.","norm_bases":["PB/43 wyd. 2 z dnia 20.09.2018 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie ozonu Zakres: (0,03 – 0,7) mg/l Metoda spektrofotometryczna PB/43 wyd. 2 z dnia 20.09.2018 r. Woda Stezenie ozonu Zakres: (0,03 – 0,7) mg/l Metoda spektrofotometryczna PB/43 wyd. 2 z dnia 20.09.2018 r.","categories":["water"],"row_index":54,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Ozone concentration Range: (0,03 – 0,7) mg/l Spectrophotometric method PB/43 wyd. 2 z dnia 20.09.2018 r.","search_zh":"水 PB/43 wyd. 2 z dnia 20.09.2018 r.","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a59","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie chloru wolnego Zakres: (0,05 – 2,00) mg/l Metoda spektrofotometryczna","methodology_en":"Free chlorine concentration Range: (0,05 – 2,00) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chloru wolnego Zakres: (0,05 – 2,00) mg/l Metoda spektrofotometryczna","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie chloru wolnego Zakres: (0,05 – 2,00) mg/l Metoda spektrofotometryczna PN-EN ISO 7393-2:2018-04 Woda Stezenie chloru wolnego Zakres: (0,05 – 2,00) mg/l Metoda spektrofotometryczna PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":55,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Free chlorine concentration Range: (0,05 – 2,00) mg/l Spectrophotometric method PN-EN ISO 7393-2:2018-04","search_zh":"水 PN-EN ISO 7393-2:2018-04","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a5a","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie chloru całkowitego Zakres: (0,05 – 2,00) mg/l Metoda spektrofotometryczna Stężenie chloru związanego / chloramin (z obliczeń)","methodology_en":"Total chlorine concentration Range: (0,05 – 2,00) mg/l Spectrophotometric method Combined chlorine / chloramine concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chloru całkowitego Zakres: (0,05 – 2,00) mg/l Metoda spektrofotometryczna Stężenie chloru związanego / chloramin (z obliczeń)","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie chloru całkowitego Zakres: (0,05 – 2,00) mg/l Metoda spektrofotometryczna Stężenie chloru związanego / chloramin (z obliczeń) PN-EN ISO 7393-2:2018-04 Woda Stezenie chloru calkowitego Zakres: (0,05 – 2,00) mg/l Metoda spektrofotometryczna Stezenie chloru zwiazanego / chloramin (z obliczen) PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":56,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Total chlorine concentration Range: (0,05 – 2,00) mg/l Spectrophotometric method Combined chlorine / chloramine concentration (calculated) PN-EN ISO 7393-2:2018-04","search_zh":"水 PN-EN ISO 7393-2:2018-04","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a5b","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie chlorków Zakres: (5 – 400) mg/l Metoda miareczkowa","methodology_en":"Chloride concentration Range: (5 – 400) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (5 – 400) mg/l Metoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie chlorków Zakres: (5 – 400) mg/l Metoda miareczkowa PN-ISO 9297:1994 Woda Stezenie chlorkow Zakres: (5 – 400) mg/l Metoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":57,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Chloride concentration Range: (5 – 400) mg/l Titrimetric method PN-ISO 9297:1994","search_zh":"水 氯化物浓度 范围：(5 – 400) mg/l 滴定法 PN-ISO 9297:1994","test_object_zh":"水","methodology_zh":"氯化物浓度 范围：(5 – 400) mg/l 滴定法"},{"_id":"6a5a55fa9af9f73f38252a5c","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (5 – 600) mg/l CaCO 3 (0,3 – 34) on Metoda miareczkowa","methodology_en":"Total calcium and magnesium content (total hardness) Range: (5 – 600) mg/l CaCO 3 (0,3 – 34) on Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (5 – 600) mg/l CaCO 3 (0,3 – 34) on Metoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (5 – 600) mg/l CaCO 3 (0,3 – 34) on Metoda miareczkowa PN-ISO 6059:1999 Woda Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna) Zakres: (5 – 600) mg/l CaCO 3 (0,3 – 34) on Metoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":58,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Total calcium and magnesium content (total hardness) Range: (5 – 600) mg/l CaCO 3 (0,3 – 34) on Titrimetric method PN-ISO 6059:1999","search_zh":"水 PN-ISO 6059:1999","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a5d","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie ortofosforanów Zakres: (0,050 – 3,00) mg/l Metoda spektrofotometryczna","methodology_en":"Orthophosphate concentration Range: (0,050 – 3,00) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie ortofosforanów Zakres: (0,050 – 3,00) mg/l Metoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie ortofosforanów Zakres: (0,050 – 3,00) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 Woda Stezenie ortofosforanow Zakres: (0,050 – 3,00) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":59,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Orthophosphate concentration Range: (0,050 – 3,00) mg/l Spectrophotometric method PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","search_zh":"水 PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a5e","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie siarczanów (VI) Zakres: (10 – 500) mg/l Metoda wagowa","methodology_en":"Sulfate (VI) concentration Range: (10 – 500) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie siarczanów (VI) Zakres: (10 – 500) mg/l Metoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie siarczanów (VI) Zakres: (10 – 500) mg/l Metoda wagowa PN-ISO 9280:2002 Woda Stezenie siarczanow (VI) Zakres: (10 – 500) mg/l Metoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":60,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Sulfate (VI) concentration Range: (10 – 500) mg/l Gravimetric method PN-ISO 9280:2002","search_zh":"水 硫酸盐(VI)浓度 范围：(10 – 500) mg/l 重量法 PN-ISO 9280:2002","test_object_zh":"水","methodology_zh":"硫酸盐(VI)浓度 范围：(10 – 500) mg/l 重量法"},{"_id":"6a5a55fa9af9f73f38252a5f","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Zawiesiny ogólne Zakres: (4,0 – 500) mg/l Metoda wagowa","methodology_en":"Total suspended solids (TSS) Range: (4,0 – 500) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: (4,0 – 500) mg/l Metoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Zawiesiny ogólne Zakres: (4,0 – 500) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007 Woda Zawiesiny ogolne Zakres: (4,0 – 500) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":61,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Total suspended solids (TSS) Range: (4,0 – 500) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007","search_zh":"水 PN-EN 872:2007+Ap1:2007","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a60","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT (Cr) Zakres: (30 – 300) mg/l O 2 Metoda miareczkowa","methodology_en":"Chemical oxygen demand - COD (Cr) Range: (30 – 300) mg/l O 2 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT (Cr) Zakres: (30 – 300) mg/l O 2 Metoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Chemiczne zapotrzebowanie tlenu - ChZT (Cr) Zakres: (30 – 300) mg/l O 2 Metoda miareczkowa PN-ISO 6060:2006 Woda Chemiczne zapotrzebowanie tlenu - ChZT (Cr) Zakres: (30 – 300) mg/l O 2 Metoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":62,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Chemical oxygen demand - COD (Cr) Range: (30 – 300) mg/l O 2 Titrimetric method PN-ISO 6060:2006","search_zh":"水 PN-ISO 6060:2006","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a61","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3 – 300) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD 5 Range: (3 – 300) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3 – 300) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019","norm_bases":["PN-EN ISO 5815-1:2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3 – 300) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019 Woda Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3 – 300) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019","categories":["water"],"row_index":63,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Biochemical oxygen demand - BOD 5 Range: (3 – 300) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019","search_zh":"水 PN-EN ISO 5815-1:2019","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a62","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,7 – 6,0) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD 5 Range: (0,7 – 6,0) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,7 – 6,0) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,7 – 6,0) mg/l O 2 Metoda elektrochemiczna PN-EN 1899-2:2002 Woda Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,7 – 6,0) mg/l O 2 Metoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":64,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Biochemical oxygen demand - BOD 5 Range: (0,7 – 6,0) mg/l O 2 Electrochemical method PN-EN 1899-2:2002","search_zh":"水 PN-EN 1899-2:2002","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a63","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Substancje ekstrahujące się eterem naftowym Zakres: (5,0 – 200) mg/l Metoda wagowa","methodology_en":"Petroleum ether extractable substances Range: (5,0 – 200) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Substancje ekstrahujące się eterem naftowym Zakres: (5,0 – 200) mg/l Metoda wagowa","reference":"PB/6/G wydanie 1 z dnia 30.09.2025","norm_bases":["PB/6/G wydanie 1 z dnia 30.09.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Substancje ekstrahujące się eterem naftowym Zakres: (5,0 – 200) mg/l Metoda wagowa PB/6/G wydanie 1 z dnia 30.09.2025 Woda, scieki Substancje ekstrahujace sie eterem naftowym Zakres: (5,0 – 200) mg/l Metoda wagowa PB/6/G wydanie 1 z dnia 30.09.2025","categories":["water"],"row_index":65,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Petroleum ether extractable substances Range: (5,0 – 200) mg/l Gravimetric method PB/6/G wydanie 1 z dnia 30.09.2025","search_zh":"水、废水 PB/6/G wydanie 1 z dnia 30.09.2025","test_object_zh":"水、废水"},{"_id":"6a5a55fa9af9f73f38252a64","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie siarczanów (VI) Zakres: (10 – 500) mg/l Metoda wagowa","methodology_en":"Sulfate (VI) concentration Range: (10 – 500) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie siarczanów (VI) Zakres: (10 – 500) mg/l Metoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie siarczanów (VI) Zakres: (10 – 500) mg/l Metoda wagowa PN-ISO 9280:2002 Scieki Stezenie siarczanow (VI) Zakres: (10 – 500) mg/l Metoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":66,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Sulfate (VI) concentration Range: (10 – 500) mg/l Gravimetric method PN-ISO 9280:2002","search_zh":"污水 硫酸盐(VI)浓度 范围：(10 – 500) mg/l 重量法 PN-ISO 9280:2002","test_object_zh":"污水","methodology_zh":"硫酸盐(VI)浓度 范围：(10 – 500) mg/l 重量法"},{"_id":"6a5a55fa9af9f73f38252a65","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"pH Zakres: (4,0 – 10,0) Metoda potencjometryczna","methodology_en":"pH Range: (4,0 – 10,0) Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: (4,0 – 10,0) Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki pH Zakres: (4,0 – 10,0) Metoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH Zakres: (4,0 – 10,0) Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":67,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater pH Range: (4,0 – 10,0) Potentiometric method PN-EN ISO 10523:2012","search_zh":"污水 pH 范围：(4,0 – 10,0) 电位法 PN-EN ISO 10523:2012","test_object_zh":"污水","methodology_zh":"pH 范围：(4,0 – 10,0) 电位法"},{"_id":"6a5a55fa9af9f73f38252a66","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Zawiesiny ogólne Zakres: (4,0 – 500) mg/l Metoda wagowa","methodology_en":"Total suspended solids (TSS) Range: (4,0 – 500) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: (4,0 – 500) mg/l Metoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Zawiesiny ogólne Zakres: (4,0 – 500) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne Zakres: (4,0 – 500) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":68,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Total suspended solids (TSS) Range: (4,0 – 500) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007","search_zh":"污水 PN-EN 872:2007+Ap1:2007","test_object_zh":"污水"},{"_id":"6a5a55fa9af9f73f38252a67","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT (Cr) Zakres: (30 – 800) mg/l O 2 Metoda miareczkowa","methodology_en":"Chemical oxygen demand - COD (Cr) Range: (30 – 800) mg/l O 2 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT (Cr) Zakres: (30 – 800) mg/l O 2 Metoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu - ChZT (Cr) Zakres: (30 – 800) mg/l O 2 Metoda miareczkowa PN-ISO 6060:2006 Scieki Chemiczne zapotrzebowanie tlenu - ChZT (Cr) Zakres: (30 – 800) mg/l O 2 Metoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":69,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Chemical oxygen demand - COD (Cr) Range: (30 – 800) mg/l O 2 Titrimetric method PN-ISO 6060:2006","search_zh":"污水 PN-ISO 6060:2006","test_object_zh":"污水"},{"_id":"6a5a55fa9af9f73f38252a68","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3 – 300) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD 5 Range: (3 – 300) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3 – 300) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019","norm_bases":["PN-EN ISO 5815-1:2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3 – 300) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019 Scieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3 – 300) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019","categories":["water"],"row_index":70,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Biochemical oxygen demand - BOD 5 Range: (3 – 300) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019","search_zh":"污水 PN-EN ISO 5815-1:2019","test_object_zh":"污水"},{"_id":"6a5a55fa9af9f73f38252a69","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,7 – 6,0) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD 5 Range: (0,7 – 6,0) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,7 – 6,0) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,7 – 6,0) mg/l O 2 Metoda elektrochemiczna PN-EN 1899-2:2002 Scieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,7 – 6,0) mg/l O 2 Metoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":71,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Biochemical oxygen demand - BOD 5 Range: (0,7 – 6,0) mg/l O 2 Electrochemical method PN-EN 1899-2:2002","search_zh":"污水 PN-EN 1899-2:2002","test_object_zh":"污水"},{"_id":"6a5a55fa9af9f73f38252a6a","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie chlorków Zakres: (10 – 800) mg/l Metoda miareczkowa","methodology_en":"Chloride concentration Range: (10 – 800) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (10 – 800) mg/l Metoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie chlorków Zakres: (10 – 800) mg/l Metoda miareczkowa PN-ISO 9297:1994 Scieki Stezenie chlorkow Zakres: (10 – 800) mg/l Metoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":72,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Chloride concentration Range: (10 – 800) mg/l Titrimetric method PN-ISO 9297:1994","search_zh":"污水 PN-ISO 9297:1994","test_object_zh":"污水"},{"_id":"6a5a55fa9af9f73f38252a6b","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu Kjeldahla Zakres: (1 – 10) mg/l Metoda miareczkowania potencjometrycznego","methodology_en":"Kjeldahl nitrogen concentration Range: (1 – 10) mg/l Potentiometric titration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla Zakres: (1 – 10) mg/l Metoda miareczkowania potencjometrycznego","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu Kjeldahla Zakres: (1 – 10) mg/l Metoda miareczkowania potencjometrycznego PN-EN 25663:2001 Scieki Stezenie azotu Kjeldahla Zakres: (1 – 10) mg/l Metoda miareczkowania potencjometrycznego PN-EN 25663:2001","categories":["water"],"row_index":73,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Kjeldahl nitrogen concentration Range: (1 – 10) mg/l Potentiometric titration method PN-EN 25663:2001","search_zh":"污水 PN-EN 25663:2001","test_object_zh":"污水"},{"_id":"6a5a55fa9af9f73f38252a6c","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie jonu amonowego Zakres: (0,05 – 2,0) mg/l Metoda spektrofotometryczna","methodology_en":"Ammonium ion concentration Range: (0,05 – 2,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego Zakres: (0,05 – 2,0) mg/l Metoda spektrofotometryczna","reference":"PN-EN ISO 7150-1:2002","norm_bases":["PN-EN ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie jonu amonowego Zakres: (0,05 – 2,0) mg/l Metoda spektrofotometryczna PN-EN ISO 7150-1:2002 Scieki Stezenie jonu amonowego Zakres: (0,05 – 2,0) mg/l Metoda spektrofotometryczna PN-EN ISO 7150-1:2002","categories":["water"],"row_index":74,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Ammonium ion concentration Range: (0,05 – 2,0) mg/l Spectrophotometric method PN-EN ISO 7150-1:2002","search_zh":"污水 PN-EN ISO 7150-1:2002","test_object_zh":"污水"},{"_id":"6a5a55fa9af9f73f38252a6d","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu organicznego (z obliczeń)","methodology_en":"Organic nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu organicznego (z obliczeń)","reference":"PB/4/G wydanie 2 z dnia 07.10.2022","norm_bases":["PB/4/G wydanie 2 z dnia 07.10.2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu organicznego (z obliczeń) PB/4/G wydanie 2 z dnia 07.10.2022 Scieki Stezenie azotu organicznego (z obliczen) PB/4/G wydanie 2 z dnia 07.10.2022","categories":["water"],"row_index":75,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Organic nitrogen concentration (calculated) PB/4/G wydanie 2 z dnia 07.10.2022","search_zh":"污水 有机氮浓度（由计算得出） PB/4/G wydanie 2 z dnia 07.10.2022","test_object_zh":"污水","methodology_zh":"有机氮浓度（由计算得出）"},{"_id":"6a5a55fa9af9f73f38252a6e","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotynów Zakres: (0,04 – 1,00) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrite concentration Range: (0,04 – 1,00) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotynów Zakres: (0,04 – 1,00) mg/l Metoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotynów Zakres: (0,04 – 1,00) mg/l Metoda spektrofotometryczna PN-EN 26777:1999 Scieki Stezenie azotynow Zakres: (0,04 – 1,00) mg/l Metoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":76,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Nitrite concentration Range: (0,04 – 1,00) mg/l Spectrophotometric method PN-EN 26777:1999","search_zh":"污水 PN-EN 26777:1999","test_object_zh":"污水"},{"_id":"6a5a55fa9af9f73f38252a6f","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB/4/G wydanie 2 z dnia 07.10.2022","norm_bases":["PB/4/G wydanie 2 z dnia 07.10.2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu ogólnego (z obliczeń) PB/4/G wydanie 2 z dnia 07.10.2022 Scieki Stezenie azotu ogolnego (z obliczen) PB/4/G wydanie 2 z dnia 07.10.2022","categories":["water"],"row_index":77,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Total nitrogen concentration (calculated) PB/4/G wydanie 2 z dnia 07.10.2022","methodology_zh":"总氮浓度（计算值）","search_zh":"污水 总氮浓度（计算值） PB/4/G wydanie 2 z dnia 07.10.2022","test_object_zh":"污水"},{"_id":"6a5a55fa9af9f73f38252a70","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotanów Zakres: (1,0 – 50) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrate concentration Range: (1,0 – 50) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotanów Zakres: (1,0 – 50) mg/l Metoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotanów Zakres: (1,0 – 50) mg/l Metoda spektrofotometryczna PN-82/C-04576/08 Scieki Stezenie azotanow Zakres: (1,0 – 50) mg/l Metoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":78,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Nitrate concentration Range: (1,0 – 50) mg/l Spectrophotometric method PN-82/C-04576/08","search_zh":"污水 PN-82/C-04576/08","test_object_zh":"污水"},{"_id":"6a5a55fa9af9f73f38252a71","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Ogólna liczba mikroorganizmów w 22°C i 36°C Metoda płytkowa (posiew wgłębny)","methodology_en":"Total microorganism count at 22°C and 36°C Plate method (pour plate)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 22°C i 36°C Metoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ogólna liczba mikroorganizmów w 22°C i 36°C Metoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda Ogolna liczba mikroorganizmow w 22°C i 36°C Metoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":79,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Total microorganism count at 22°C and 36°C Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"水 22°C 与 36°C 微生物总数 平板法（倾注平板） PN-EN ISO 6222:2004","test_object_zh":"水","methodology_zh":"22°C 与 36°C 微生物总数 平板法（倾注平板）"},{"_id":"6a5a55fa9af9f73f38252a72","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba Enterokoków kałowych Metoda filtracji membranowej","methodology_en":"Intestinal enterococci count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba Enterokoków kałowych Metoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba Enterokoków kałowych Metoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda Liczba Enterokokow kalowych Metoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":80,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","methodology_zh":"粪肠球菌计数 膜过滤法","search_zh":"水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a73","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba bakterii grupy coli i Escherichia coli Metoda filtracji membranowej","methodology_en":"Coliform bacteria and Escherichia coli count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli i Escherichia coli Metoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba bakterii grupy coli i Escherichia coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda Liczba bakterii grupy coli i Escherichia coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["microbiology","water"],"row_index":81,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Coliform bacteria and Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","search_zh":"水 大肠菌群与大肠埃希氏菌数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","test_object_zh":"水","methodology_zh":"大肠菌群与大肠埃希氏菌数 膜过滤法"},{"_id":"6a5a55fa9af9f73f38252a74","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Mętność Zakres: (0,10 – 40,0) NTU Metoda nefelometryczna","methodology_en":"Turbidity Range: (0,10 – 40,0) NTU Nephelometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Mętność Zakres: (0,10 – 40,0) NTU Metoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Mętność Zakres: (0,10 – 40,0) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda Metnosc Zakres: (0,10 – 40,0) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":82,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Turbidity Range: (0,10 – 40,0) NTU Nephelometric method PN-EN ISO 7027-1:2016-09","search_zh":"水 PN-EN ISO 7027-1:2016-09","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a75","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie chloru całkowitego Zakres: (0,05 – 2,0) mg/l Metoda spektrofotometryczna Stężenie chloru związanego / chloramin (z obliczeń)","methodology_en":"Total chlorine concentration Range: (0,05 – 2,0) mg/l Spectrophotometric method Combined chlorine / chloramine concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chloru całkowitego Zakres: (0,05 – 2,0) mg/l Metoda spektrofotometryczna Stężenie chloru związanego / chloramin (z obliczeń)","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie chloru całkowitego Zakres: (0,05 – 2,0) mg/l Metoda spektrofotometryczna Stężenie chloru związanego / chloramin (z obliczeń) PN-EN ISO 7393-2:2018-04 Woda Stezenie chloru calkowitego Zakres: (0,05 – 2,0) mg/l Metoda spektrofotometryczna Stezenie chloru zwiazanego / chloramin (z obliczen) PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":83,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Total chlorine concentration Range: (0,05 – 2,0) mg/l Spectrophotometric method Combined chlorine / chloramine concentration (calculated) PN-EN ISO 7393-2:2018-04","search_zh":"水 PN-EN ISO 7393-2:2018-04","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a76","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie manganu Zakres: (0,015 – 0,50) mg/l Metoda spektrofotometryczna","methodology_en":"Manganese concentration Range: (0,015 – 0,50) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie manganu Zakres: (0,015 – 0,50) mg/l Metoda spektrofotometryczna","reference":"PN-92/C-04590/02","norm_bases":["PN-92/C-04590/02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie manganu Zakres: (0,015 – 0,50) mg/l Metoda spektrofotometryczna PN-92/C-04590/02 Woda Stezenie manganu Zakres: (0,015 – 0,50) mg/l Metoda spektrofotometryczna PN-92/C-04590/02","categories":["water"],"row_index":84,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Manganese concentration Range: (0,015 – 0,50) mg/l Spectrophotometric method PN-92/C-04590/02","search_zh":"水 PN-92/C-04590/02","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a77","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (10 – 600) mg/l CaCO 3 (0,6 – 33,6) on Metoda miareczkowa","methodology_en":"Total calcium and magnesium content (total hardness) Range: (10 – 600) mg/l CaCO 3 (0,6 – 33,6) on Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (10 – 600) mg/l CaCO 3 (0,6 – 33,6) on Metoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (10 – 600) mg/l CaCO 3 (0,6 – 33,6) on Metoda miareczkowa PN-ISO 6059:1999 Woda Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna) Zakres: (10 – 600) mg/l CaCO 3 (0,6 – 33,6) on Metoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":85,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Total calcium and magnesium content (total hardness) Range: (10 – 600) mg/l CaCO 3 (0,6 – 33,6) on Titrimetric method PN-ISO 6059:1999","search_zh":"水 PN-ISO 6059:1999","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a78","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie azotynów Zakres: (0,04 – 1,00) mg/l Stężenie azotu azotynowego Zakres: (0,01 – 0,30) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrite concentration Range: (0,04 – 1,00) mg/l Nitrite nitrogen concentration Range: (0,01 – 0,30) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotynów Zakres: (0,04 – 1,00) mg/l Stężenie azotu azotynowego Zakres: (0,01 – 0,30) mg/l Metoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie azotynów Zakres: (0,04 – 1,00) mg/l Stężenie azotu azotynowego Zakres: (0,01 – 0,30) mg/l Metoda spektrofotometryczna PN-EN 26777:1999 Woda Stezenie azotynow Zakres: (0,04 – 1,00) mg/l Stezenie azotu azotynowego Zakres: (0,01 – 0,30) mg/l Metoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":86,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Nitrite concentration Range: (0,04 – 1,00) mg/l Nitrite nitrogen concentration Range: (0,01 – 0,30) mg/l Spectrophotometric method PN-EN 26777:1999","search_zh":"水 PN-EN 26777:1999","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a79","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie azotanów Zakres: (1,0 – 100,0) mg/l Stężenie azotu azotanowego Zakres: (0,25 – 22,0) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrate concentration Range: (1,0 – 100,0) mg/l Nitrate nitrogen concentration Range: (0,25 – 22,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotanów Zakres: (1,0 – 100,0) mg/l Stężenie azotu azotanowego Zakres: (0,25 – 22,0) mg/l Metoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie azotanów Zakres: (1,0 – 100,0) mg/l Stężenie azotu azotanowego Zakres: (0,25 – 22,0) mg/l Metoda spektrofotometryczna PN-82/C-04576/08 Woda Stezenie azotanow Zakres: (1,0 – 100,0) mg/l Stezenie azotu azotanowego Zakres: (0,25 – 22,0) mg/l Metoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":87,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Nitrate concentration Range: (1,0 – 100,0) mg/l Nitrate nitrogen concentration Range: (0,25 – 22,0) mg/l Spectrophotometric method PN-82/C-04576/08","search_zh":"水 PN-82/C-04576/08","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a7a","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie rtęci Zakres: (0,0005 – 0,010) mg/l Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","methodology_en":"Mercury concentration Range: (0,0005 – 0,010) mg/l Atomic absorption spectrometry with amalgamation technique","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie rtęci Zakres: (0,0005 – 0,010) mg/l Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB/31/M wydanie 2 z dnia 21.10.2024","norm_bases":["PB/31/M wydanie 2 z dnia 21.10.2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie rtęci Zakres: (0,0005 – 0,010) mg/l Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB/31/M wydanie 2 z dnia 21.10.2024 Woda Stezenie rteci Zakres: (0,0005 – 0,010) mg/l Metoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB/31/M wydanie 2 z dnia 21.10.2024","categories":["water"],"row_index":88,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Mercury concentration Range: (0,0005 – 0,010) mg/l Atomic absorption spectrometry with amalgamation technique PB/31/M wydanie 2 z dnia 21.10.2024","search_zh":"水 PB/31/M wydanie 2 z dnia 21.10.2024","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a7b","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie antymonu Zakres: (0,0005 – 0,010) mg/l Metoda absorpcyjnej spektrometrii atomowej z generacją wodorków (HGAAS)","methodology_en":"Antimony concentration Range: (0,0005 – 0,010) mg/l Hydride generation atomic absorption spectrometry (HGAAS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie antymonu Zakres: (0,0005 – 0,010) mg/l Metoda absorpcyjnej spektrometrii atomowej z generacją wodorków (HGAAS)","reference":"PB/6/M wydanie 5 z dnia 21.10.2024","norm_bases":["PB/6/M wydanie 5 z dnia 21.10.2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie antymonu Zakres: (0,0005 – 0,010) mg/l Metoda absorpcyjnej spektrometrii atomowej z generacją wodorków (HGAAS) PB/6/M wydanie 5 z dnia 21.10.2024 Woda Stezenie antymonu Zakres: (0,0005 – 0,010) mg/l Metoda absorpcyjnej spektrometrii atomowej z generacja wodorkow (HGAAS) PB/6/M wydanie 5 z dnia 21.10.2024","categories":["water"],"row_index":89,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Antimony concentration Range: (0,0005 – 0,010) mg/l Hydride generation atomic absorption spectrometry (HGAAS) PB/6/M wydanie 5 z dnia 21.10.2024","search_zh":"水 PB/6/M wydanie 5 z dnia 21.10.2024","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a7c","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie siarczanów (VI) Zakres: (20 - 300) mg/l Metoda turbidymetryczna","methodology_en":"Sulphate (VI) concentration Range: (20 - 300) mg/l Turbidimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie siarczanów (VI) Zakres: (20 - 300) mg/l Metoda turbidymetryczna","reference":"PB/17/M wydanie 3 z dnia 31.05.2019 r. na podstawie testu Nanocolor nr 985 086; nr 985 087 i nr 985 062","norm_bases":["PB/17/M wydanie 3 z dnia 31.05.2019 r. na podstawie testu Nanocolor nr 985 086; nr 985 087 i nr 985 062"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie siarczanów (VI) Zakres: (20 - 300) mg/l Metoda turbidymetryczna PB/17/M wydanie 3 z dnia 31.05.2019 r. na podstawie testu Nanocolor nr 985 086; nr 985 087 i nr 985 062 Woda Stezenie siarczanow (VI) Zakres: (20 - 300) mg/l Metoda turbidymetryczna PB/17/M wydanie 3 z dnia 31.05.2019 r. na podstawie testu Nanocolor nr 985 086; nr 985 087 i nr 985 062","categories":["water"],"row_index":90,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Sulphate (VI) concentration Range: (20 - 300) mg/l Turbidimetric method PB/17/M wydanie 3 z dnia 31.05.2019 r. na podstawie testu Nanocolor nr 985 086; nr 985 087 i nr 985 062","search_zh":"水 PB/17/M wydanie 3 z dnia 31.05.2019 r. na podstawie testu Nanocolor nr 985 086; nr 985 087 i nr 985 062","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a7d","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie siarczanów (VI) Zakres: (10 – 500) mg/l Metoda wagowa","methodology_en":"Sulfate (VI) concentration Range: (10 – 500) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie siarczanów (VI) Zakres: (10 – 500) mg/l Metoda wagowa","reference":"PN-ISO 9280: 2002","norm_bases":["PN-ISO 9280: 2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie siarczanów (VI) Zakres: (10 – 500) mg/l Metoda wagowa PN-ISO 9280: 2002 Woda Stezenie siarczanow (VI) Zakres: (10 – 500) mg/l Metoda wagowa PN-ISO 9280: 2002","categories":["water"],"row_index":91,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Sulfate (VI) concentration Range: (10 – 500) mg/l Gravimetric method PN-ISO 9280: 2002","search_zh":"水 硫酸盐(VI)浓度 范围：(10 – 500) mg/l 重量法 PN-ISO 9280: 2002","test_object_zh":"水","methodology_zh":"硫酸盐(VI)浓度 范围：(10 – 500) mg/l 重量法"},{"_id":"6a5a55fa9af9f73f38252a7e","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Zawiesiny ogólne Zakres: (2,0 – 500) mg/l Metoda wagowa","methodology_en":"Total suspended solids (TSS) Range: (2,0 – 500) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: (2,0 – 500) mg/l Metoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Zawiesiny ogólne Zakres: (2,0 – 500) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007 Woda Zawiesiny ogolne Zakres: (2,0 – 500) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":92,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Total suspended solids (TSS) Range: (2,0 – 500) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007","search_zh":"水 总悬浮物 范围：(2,0 – 500) mg/l 重量法 PN-EN 872:2007+Ap1:2007","test_object_zh":"水","methodology_zh":"总悬浮物 范围：(2,0 – 500) mg/l 重量法"},{"_id":"6a5a55fa9af9f73f38252a7f","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT (Cr) Zakres: (10 – 200) mg/l O 2 Metoda spektrofotometryczna","methodology_en":"Chemical oxygen demand - COD (Cr) Range: (10 – 200) mg/l O 2 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT (Cr) Zakres: (10 – 200) mg/l O 2 Metoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Chemiczne zapotrzebowanie tlenu - ChZT (Cr) Zakres: (10 – 200) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005 Woda Chemiczne zapotrzebowanie tlenu - ChZT (Cr) Zakres: (10 – 200) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":93,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Chemical oxygen demand - COD (Cr) Range: (10 – 200) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005","search_zh":"水 PN-ISO 15705:2005","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a80","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,6 – 6,0) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD 5 Range: (0,6 – 6,0) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,6 – 6,0) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,6 – 6,0) mg/l O 2 Metoda elektrochemiczna PN-EN 1899-2:2002 Woda Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,6 – 6,0) mg/l O 2 Metoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":94,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Biochemical oxygen demand - BOD 5 Range: (0,6 – 6,0) mg/l O 2 Electrochemical method PN-EN 1899-2:2002","search_zh":"水 PN-EN 1899-2:2002","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a81","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Indeks nadmanganiowy Zakres: (0,5 – 10) mg/l Metoda miareczkowa","methodology_en":"Permanganate index Range: (0,5 – 10) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indeks nadmanganiowy Zakres: (0,5 – 10) mg/l Metoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Indeks nadmanganiowy Zakres: (0,5 – 10) mg/l Metoda miareczkowa PN-EN ISO 8467:2001 Woda Indeks nadmanganiowy Zakres: (0,5 – 10) mg/l Metoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":95,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Permanganate index Range: (0,5 – 10) mg/l Titrimetric method PN-EN ISO 8467:2001","search_zh":"水 PN-EN ISO 8467:2001","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a82","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Indeks fenolowy Zakres: (0,005 – 0,100) mg/l Metoda spektrofotometryczna","methodology_en":"Phenol index Range: (0,005 – 0,100) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indeks fenolowy Zakres: (0,005 – 0,100) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 6439:1994","norm_bases":["PN-ISO 6439:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Indeks fenolowy Zakres: (0,005 – 0,100) mg/l Metoda spektrofotometryczna PN-ISO 6439:1994 Woda Indeks fenolowy Zakres: (0,005 – 0,100) mg/l Metoda spektrofotometryczna PN-ISO 6439:1994","categories":["water"],"row_index":96,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Phenol index Range: (0,005 – 0,100) mg/l Spectrophotometric method PN-ISO 6439:1994","search_zh":"水 PN-ISO 6439:1994","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a83","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie krzemianów Zakres: (1 – 50) mg/l SiO 2 Metoda spektrofotometryczna","methodology_en":"Silicate concentration Range: (1 – 50) mg/l SiO 2 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie krzemianów Zakres: (1 – 50) mg/l SiO 2 Metoda spektrofotometryczna","reference":"PB/14/M wydanie 2 z dnia 30.06.2022 na postawie testu Nanocolor 918 48","norm_bases":["PB/14/M wydanie 2 z dnia 30.06.2022 na postawie testu Nanocolor 918 48"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie krzemianów Zakres: (1 – 50) mg/l SiO 2 Metoda spektrofotometryczna PB/14/M wydanie 2 z dnia 30.06.2022 na postawie testu Nanocolor 918 48 Woda Stezenie krzemianow Zakres: (1 – 50) mg/l SiO 2 Metoda spektrofotometryczna PB/14/M wydanie 2 z dnia 30.06.2022 na postawie testu Nanocolor 918 48","categories":["water"],"row_index":97,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Silicate concentration Range: (1 – 50) mg/l SiO 2 Spectrophotometric method PB/14/M wydanie 2 z dnia 30.06.2022 na postawie testu Nanocolor 918 48","search_zh":"水 PB/14/M wydanie 2 z dnia 30.06.2022 na postawie testu Nanocolor 918 48","test_object_zh":"水"},{"_id":"6a5a55fa9af9f73f38252a84","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie siarczanów (VI) Zakres: (10 – 500) mg/l Metoda wagowa","methodology_en":"Sulfate (VI) concentration Range: (10 – 500) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie siarczanów (VI) Zakres: (10 – 500) mg/l Metoda wagowa","reference":"PN-ISO 9280: 2002","norm_bases":["PN-ISO 9280: 2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie siarczanów (VI) Zakres: (10 – 500) mg/l Metoda wagowa PN-ISO 9280: 2002 Scieki Stezenie siarczanow (VI) Zakres: (10 – 500) mg/l Metoda wagowa PN-ISO 9280: 2002","categories":["water"],"row_index":98,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Sulfate (VI) concentration Range: (10 – 500) mg/l Gravimetric method PN-ISO 9280: 2002","search_zh":"污水 硫酸盐(VI)浓度 范围：(10 – 500) mg/l 重量法 PN-ISO 9280: 2002","test_object_zh":"污水","methodology_zh":"硫酸盐(VI)浓度 范围：(10 – 500) mg/l 重量法"},{"_id":"6a5a55fa9af9f73f38252a85","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Zawiesiny ogólne Zakres: (2,0 – 500) mg/l Metoda wagowa","methodology_en":"Total suspended solids (TSS) Range: (2,0 – 500) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: (2,0 – 500) mg/l Metoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Zawiesiny ogólne Zakres: (2,0 – 500) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne Zakres: (2,0 – 500) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":99,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Total suspended solids (TSS) Range: (2,0 – 500) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007","search_zh":"污水 总悬浮物 范围：(2,0 – 500) mg/l 重量法 PN-EN 872:2007+Ap1:2007","test_object_zh":"污水","methodology_zh":"总悬浮物 范围：(2,0 – 500) mg/l 重量法"},{"_id":"6a5a55fa9af9f73f38252a86","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT (Cr) Zakres: (10 – 800) mg/l O 2 Metoda spektrofotometryczna","methodology_en":"Chemical oxygen demand - COD (Cr) Range: (10 – 800) mg/l O 2 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT (Cr) Zakres: (10 – 800) mg/l O 2 Metoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu - ChZT (Cr) Zakres: (10 – 800) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu - ChZT (Cr) Zakres: (10 – 800) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":100,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Chemical oxygen demand - COD (Cr) Range: (10 – 800) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005","search_zh":"污水 PN-ISO 15705:2005","test_object_zh":"污水"},{"_id":"6a5a55fa9af9f73f38252a87","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Indeks fenolowy Zakres: (0,005 – 0,100) mg/l Metoda spektrofotometryczna","methodology_en":"Phenol index Range: (0,005 – 0,100) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indeks fenolowy Zakres: (0,005 – 0,100) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 6439:1994","norm_bases":["PN-ISO 6439:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Indeks fenolowy Zakres: (0,005 – 0,100) mg/l Metoda spektrofotometryczna PN-ISO 6439:1994 Scieki Indeks fenolowy Zakres: (0,005 – 0,100) mg/l Metoda spektrofotometryczna PN-ISO 6439:1994","categories":["water"],"row_index":101,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Phenol index Range: (0,005 – 0,100) mg/l Spectrophotometric method PN-ISO 6439:1994","search_zh":"污水 PN-ISO 6439:1994","test_object_zh":"污水"},{"_id":"6a5a55fa9af9f73f38252a88","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie surfaktantów anionowych (anionowych substancji powierzchniowo czynnych) Zakres: (0,1 – 5,0) mg/l Metoda spektrofotometryczna","methodology_en":"Anionic surfactant concentration (anionic surface active agents) Range: (0,1 – 5,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie surfaktantów anionowych (anionowych substancji powierzchniowo czynnych) Zakres: (0,1 – 5,0) mg/l Metoda spektrofotometryczna","reference":"PB/5/M wydanie 2 z dnia 10.12.2024 r. na podstawie testów kuwetowych Hach Lange nr LCK 432","norm_bases":["PB/5/M wydanie 2 z dnia 10.12.2024 r. na podstawie testów kuwetowych Hach Lange nr LCK 432"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie surfaktantów anionowych (anionowych substancji powierzchniowo czynnych) Zakres: (0,1 – 5,0) mg/l Metoda spektrofotometryczna PB/5/M wydanie 2 z dnia 10.12.2024 r. na podstawie testów kuwetowych Hach Lange nr LCK 432 Woda, scieki Stezenie surfaktantow anionowych (anionowych substancji powierzchniowo czynnych) Zakres: (0,1 – 5,0) mg/l Metoda spektrofotometryczna PB/5/M wydanie 2 z dnia 10.12.2024 r. na podstawie testow kuwetowych Hach Lange nr LCK 432","categories":["water"],"row_index":102,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Anionic surfactant concentration (anionic surface active agents) Range: (0,1 – 5,0) mg/l Spectrophotometric method PB/5/M wydanie 2 z dnia 10.12.2024 r. na podstawie testów kuwetowych Hach Lange nr LCK 432","search_zh":"水、废水 PB/5/M wydanie 2 z dnia 10.12.2024 r. na podstawie testów kuwetowych Hach Lange nr LCK 432","test_object_zh":"水、废水"},{"_id":"6a5a55fa9af9f73f38252a89","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie surfaktantów niejonowych (niejonowych substancji powierzchniowo czynnych) Zakres: (0,2 – 10,0) mg/l Metoda spektrofotometryczna","methodology_en":"Non-ionic surfactant concentration (non-ionic surface active agents) Range: (0,2 – 10,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie surfaktantów niejonowych (niejonowych substancji powierzchniowo czynnych) Zakres: (0,2 – 10,0) mg/l Metoda spektrofotometryczna","reference":"PB/5/M wydanie 2 z dnia 10.12.2024 r. na podstawie testów kuwetowych Hach Lange nr LCK 333","norm_bases":["PB/5/M wydanie 2 z dnia 10.12.2024 r. na podstawie testów kuwetowych Hach Lange nr LCK 333"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie surfaktantów niejonowych (niejonowych substancji powierzchniowo czynnych) Zakres: (0,2 – 10,0) mg/l Metoda spektrofotometryczna PB/5/M wydanie 2 z dnia 10.12.2024 r. na podstawie testów kuwetowych Hach Lange nr LCK 333 Woda, scieki Stezenie surfaktantow niejonowych (niejonowych substancji powierzchniowo czynnych) Zakres: (0,2 – 10,0) mg/l Metoda spektrofotometryczna PB/5/M wydanie 2 z dnia 10.12.2024 r. na podstawie testow kuwetowych Hach Lange nr LCK 333","categories":["water"],"row_index":103,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Non-ionic surfactant concentration (non-ionic surface active agents) Range: (0,2 – 10,0) mg/l Spectrophotometric method PB/5/M wydanie 2 z dnia 10.12.2024 r. na podstawie testów kuwetowych Hach Lange nr LCK 333","search_zh":"水、废水 PB/5/M wydanie 2 z dnia 10.12.2024 r. na podstawie testów kuwetowych Hach Lange nr LCK 333","test_object_zh":"水、废水"},{"_id":"6a5a55fa9af9f73f38252a8a","lab_id":"69ad52a3de79e566650fb5ea","country":"PL","accr_number":"AB 1158","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Suma surfaktantów anionowych i niejonowych (z obliczeń)","methodology_en":"Sum of anionic and non-ionic surfactants (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma surfaktantów anionowych i niejonowych (z obliczeń)","reference":"PB/5/M wydanie 2 z dnia 10.12.2024 r. na podstawie testów kuwetowych Hach Lange nr LCK 432 i LCK 333","norm_bases":["PB/5/M wydanie 2 z dnia 10.12.2024 r. na podstawie testów kuwetowych Hach Lange nr LCK 432 i LCK 333"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Suma surfaktantów anionowych i niejonowych (z obliczeń) PB/5/M wydanie 2 z dnia 10.12.2024 r. na podstawie testów kuwetowych Hach Lange nr LCK 432 i LCK 333 Woda, scieki Suma surfaktantow anionowych i niejonowych (z obliczen) PB/5/M wydanie 2 z dnia 10.12.2024 r. na podstawie testow kuwetowych Hach Lange nr LCK 432 i LCK 333","categories":["water"],"row_index":104,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Sum of anionic and non-ionic surfactants (calculated) PB/5/M wydanie 2 z dnia 10.12.2024 r. na podstawie testów kuwetowych Hach Lange nr LCK 432 i LCK 333","search_zh":"水、废水 PB/5/M wydanie 2 z dnia 10.12.2024 r. na podstawie testów kuwetowych Hach Lange nr LCK 432 i LCK 333","test_object_zh":"水、废水"}],"has_pdf":true}