{"lab":{"_id":"69ad52a3de79e566650fb5c4","accr_number":"AB 1128","country":"PL","accr_body":"PCA","address":"DZIAŁ JAKOŚCI WODY I ŚCIEKÓW, ul. Oficerska 16 a, 10-218 Olsztyn","categories":["water","microbiology"],"city":"Olsztyn","imported_at":"2026-03-08T10:42:43.265Z","methods_count":43,"name":"PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1128.pdf"],"scope_summary":"","search_text":"przedsiębiorstwo wodociągów i kanalizacji sp. z o.o. dział jakości wody i ścieków, ul. oficerska 16 a, 10-218 olsztyn microbiology water other automotive pharma electronics","status":"active","updated_at":"2026-03-08T14:50:18.416Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T07:57:26.218Z","email_confidence":"high","email_mx":true,"email_source":"https://pwik.olsztyn.pl/kontakt/","parse_date":"2026-08-13T07:57:26.218Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of drinking water, sewage"},{"codes":"K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody do spożycia przez ludzi","en":"Microbiological tests and sampling of drinking water"},{"codes":"N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of drinking water, sewage"},{"codes":"N/32","pl":"Badania właściwości fizycznych osadów","en":"Tests of physical properties of sediments"}],"issue":{"no":"18","date":"08.06.2026"},"map_coord":[53.800845,20.491954],"map_geo":"nominatim-street","lab_locations":[{"name":"DZIAŁ JAKOŚCI WODY I ŚCIEKÓW","address":"ul. Oficerska 16 a","city":null,"postal":null},{"name":"Pracownia Mikrobiologiczna","address":"ul. Oficerska 16a, 10-218 Olsztyn","city":"Olsztyn","postal":"10-218"},{"name":"Pracownia Chemii Wody","address":"ul. Oficerska 16a, 10-218 Olsztyn","city":"Olsztyn","postal":"10-218"},{"name":"Pracownia Chemii Ścieków","address":"ul. Leśna 9, 10-173 Olsztyn","city":"Olsztyn","postal":"10-173"},{"name":"Dział Jakości Wody i Ścieków; Pracownia Chemii Wody","address":null,"city":null,"postal":null},{"name":"Dział Jakości Wody i Ścieków; Pracownia Chemii Ścieków","address":null,"city":null,"postal":null},{"name":"Dział Jakości Wody i Ścieków; Pracownia Mikrobiologiczna","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/e0708e67272a873ea446de5ce18e7b0a/AB%201128.pdf","has_en":true,"category_counts":{"water":43,"microbiology":5},"category_scores":{"water":38.52,"microbiology":0.52},"has_zh":true,"lab_locations_zh":[{"name":"DZIAŁ JAKOŚCI WODY I ŚCIEKÓW","address":"ul. Oficerska 16 a","city":null,"postal":null},{"name":"Pracownia Mikrobiologiczna","address":"ul. Oficerska 16a, 10-218 Olsztyn","city":"Olsztyn","postal":"10-218"},{"name":"水化学实验室","address":"ul. Oficerska 16a, 10-218 Olsztyn","city":"Olsztyn","postal":"10-218"},{"name":"Pracownia Chemii Ścieków","address":"ul. Leśna 9, 10-173 Olsztyn","city":"Olsztyn","postal":"10-173"},{"name":"水与废水质量部；水化学检验室","address":null,"city":null,"postal":null},{"name":"水与废水质量部；废水化学实验室","address":null,"city":null,"postal":null},{"name":"水与废水质量部；微生物检验室","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7d78e60636ba417e41a3da","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Microbiology Laboratory","methodology_en":"Sampling for microbiological testing","search_en":"Water intended for human consumption Sampling for microbiological testing Water and Wastewater Quality Department; Microbiology Laboratory PN-EN ISO 19458:2007","test_object_en":"Water intended for human consumption","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 水与废水质量部；微生物检验室 PN-EN ISO 19458:2007","test_object_zh":"生活饮用水","lab_section_zh":"水与废水质量部；微生物检验室"},{"_id":"6a7d78e60636ba417e41a3db","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temp. 36°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temp. 36°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. 36°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. 36°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Microbiology Laboratory","methodology_en":"Total viable count at 36°C","search_en":"Water intended for human consumption Total viable count at 36°C Plate method (pour plate) Water and Wastewater Quality Department; Microbiology Laboratory PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 36°C 微生物总数 平板法（倾注培养） 水与废水质量部；微生物检验室 PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水","methodology_zh":"36°C 微生物总数","lab_section_zh":"水与废水质量部；微生物检验室"},{"_id":"6a7d78e60636ba417e41a3dc","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temp. 22°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temp. 22°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. 22°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. 22°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Microbiology Laboratory","methodology_en":"Total viable count at 22°C","search_en":"Water intended for human consumption Total viable count at 22°C Plate method (pour plate) Water and Wastewater Quality Department; Microbiology Laboratory PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water intended for human consumption","methodology_zh":"22°C 微生物总数","search_zh":"生活饮用水 22°C 微生物总数 平板法（倾注培养） 水与废水质量部；微生物检验室 PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水","lab_section_zh":"水与废水质量部；微生物检验室"},{"_id":"6a7d78e60636ba417e41a3dd","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12/ A1:2017-04"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04 Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","categories":["water","microbiology"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Microbiology Laboratory","methodology_en":"Coliform bacteria count","search_en":"Water intended for human consumption Coliform bacteria count Membrane filtration method Water and Wastewater Quality Department; Microbiology Laboratory PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","methodology_zh":"大肠菌群计数","search_zh":"生活饮用水 大肠菌群计数 膜过滤法 水与废水质量部；微生物检验室 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水","lab_section_zh":"水与废水质量部；微生物检验室"},{"_id":"6a7d78e60636ba417e41a3de","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12/ A1:2017-04"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04 Woda do spozycia przez ludzi Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","categories":["microbiology","water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Microbiology Laboratory","methodology_en":"Escherichia coli count","search_en":"Water intended for human consumption Escherichia coli count Membrane filtration method Water and Wastewater Quality Department; Microbiology Laboratory PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 水与废水质量部；微生物检验室 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水","lab_section_zh":"水与废水质量部；微生物检验室"},{"_id":"6a7d78e60636ba417e41a3df","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Microbiology Laboratory","methodology_en":"Intestinal enterococci count","search_en":"Water intended for human consumption Intestinal enterococci count Membrane filtration method Water and Wastewater Quality Department; Microbiology Laboratory PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","methodology_zh":"粪肠球菌计数","search_zh":"生活饮用水 粪肠球菌计数 膜过滤法 水与废水质量部；微生物检验室 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"生活饮用水","lab_section_zh":"水与废水质量部；微生物检验室"},{"_id":"6a7d78e60636ba417e41a3e0","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba enterokoków kałowych","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba enterokoków kałowych\nMetoda NPL","reference":"PN-EN ISO 7899-3:2025-11","norm_bases":["PN-EN ISO 7899-3:2025-11"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba enterokoków kałowych\nMetoda NPL PN-EN ISO 7899-3:2025-11 Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba enterokokow kalowych\nMetoda NPL PN-EN ISO 7899-3:2025-11","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Microbiology Laboratory","methodology_en":"Most probable number of intestinal enterococci","search_en":"Water intended for human consumption Most probable number of intestinal enterococci MPN method Water and Wastewater Quality Department; Microbiology Laboratory PN-EN ISO 7899-3:2025-11","technique_en":"MPN method","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 粪肠球菌最可能数 最可能数法（MPN） 水与废水质量部；微生物检验室 PN-EN ISO 7899-3:2025-11","technique_zh":"最可能数法（MPN）","test_object_zh":"生活饮用水","lab_section_zh":"水与废水质量部；微生物检验室","methodology_zh":"粪肠球菌最可能数"},{"_id":"6a7d78e60636ba417e41a3e1","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Microbiology Laboratory","methodology_en":"Most probable number of coliform bacteria","search_en":"Water intended for human consumption Most probable number of coliform bacteria MPN method Water and Wastewater Quality Department; Microbiology Laboratory PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water intended for human consumption","methodology_zh":"大肠菌群最可能数（MPN）","search_zh":"生活饮用水 大肠菌群最可能数（MPN） 最可能数法（MPN） 水与废水质量部；微生物检验室 PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"生活饮用水","lab_section_zh":"水与废水质量部；微生物检验室"},{"_id":"6a7d78e60636ba417e41a3e2","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba bakterii Escherichia coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba bakterii Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba bakterii Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba bakterii Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["microbiology","water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Microbiology Laboratory","methodology_en":"Most probable number of Escherichia coli","search_en":"Water intended for human consumption Most probable number of Escherichia coli MPN method Water and Wastewater Quality Department; Microbiology Laboratory PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 大肠埃希氏菌最可能数 最可能数法（MPN） 水与废水质量部；微生物检验室 PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"生活饮用水","methodology_zh":"大肠埃希氏菌最可能数","lab_section_zh":"水与废水质量部；微生物检验室"},{"_id":"6a7d78e60636ba417e41a3e3","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Water Chemistry Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Water intended for human consumption Sampling for chemical and physical testing Water and Wastewater Quality Department; Water Chemistry Laboratory PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 水与废水质量部；水化学检验室 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水","lab_section_zh":"水与废水质量部；水化学检验室"},{"_id":"6a7d78e60636ba417e41a3e4","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 – 50) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (5 – 50) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 Metoda C + Ap1:2015","norm_bases":["PN-EN ISO 7887:2012 Metoda C + Ap1:2015"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Barwa\nZakres (5 – 50) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C + Ap1:2015 Woda do spozycia przez ludzi Barwa\nZakres (5 – 50) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C + Ap1:2015","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Water Chemistry Laboratory","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 – 50) mg/l Pt"}],"search_en":"Water intended for human consumption Colour Spectrophotometric method Water and Wastewater Quality Department; Water Chemistry Laboratory Range PN-EN ISO 7887:2012 Metoda C + Ap1:2015","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 50) mg/l Pt"}],"search_zh":"生活饮用水 色度 分光光度法 水与废水质量部；水化学检验室 范围 PN-EN ISO 7887:2012 Metoda C + Ap1:2015","technique_zh":"分光光度法","test_object_zh":"生活饮用水","lab_section_zh":"水与废水质量部；水化学检验室"},{"_id":"6a7d78e60636ba417e41a3e5","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(10 – 1000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (10 – 1000) μg/l\nMetoda spektrofotometryczna","reference":"PBL/W-02 edycja 4 wydanie z dnia 02.03.2026 r. | na podstawie testu kuwetowego Merck 1.14770.0001","norm_bases":["PBL/W-02 edycja 4 wydanie z dnia 02.03.2026 r.","na podstawie testu kuwetowego Merck 1.14770.0001"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie manganu\nZakres (10 – 1000) μg/l\nMetoda spektrofotometryczna PBL/W-02 edycja 4 wydanie z dnia 02.03.2026 r. | na podstawie testu kuwetowego Merck 1.14770.0001 Woda do spozycia przez ludzi Stezenie manganu\nZakres (10 – 1000) μg/l\nMetoda spektrofotometryczna PBL/W-02 edycja 4 wydanie z dnia 02.03.2026 r. | na podstawie testu kuwetowego Merck 1.14770.0001","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Water Chemistry Laboratory","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(10 – 1000) μg/l"}],"search_en":"Water intended for human consumption Manganese concentration Spectrophotometric method Water and Wastewater Quality Department; Water Chemistry Laboratory Range PBL/W-02 edycja 4 wydanie z dnia 02.03.2026 r. | na podstawie testu kuwetowego Merck 1.14770.0001","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(10 – 1000) μg/l"}],"search_zh":"生活饮用水 锰浓度 分光光度法 水与废水质量部；水化学检验室 范围 PBL/W-02 edycja 4 wydanie z dnia 02.03.2026 r. | na podstawie testu kuwetowego Merck 1.14770.0001","technique_zh":"分光光度法","test_object_zh":"生活饮用水","lab_section_zh":"水与废水质量部；水化学检验室"},{"_id":"6a7d78e60636ba417e41a3e6","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(10 – 5000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (10 – 5000) μg/l\nMetoda spektrofotometryczna","reference":"PBL/W-03 edycja 4 wydanie z dnia 02.03.2026 r. | na podstawie testu kuwetowego Merck 1.14761.0001","norm_bases":["PBL/W-03 edycja 4 wydanie z dnia 02.03.2026 r.","na podstawie testu kuwetowego Merck 1.14761.0001"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie żelaza ogólnego\nZakres (10 – 5000) μg/l\nMetoda spektrofotometryczna PBL/W-03 edycja 4 wydanie z dnia 02.03.2026 r. | na podstawie testu kuwetowego Merck 1.14761.0001 Woda do spozycia przez ludzi Stezenie zelaza ogolnego\nZakres (10 – 5000) μg/l\nMetoda spektrofotometryczna PBL/W-03 edycja 4 wydanie z dnia 02.03.2026 r. | na podstawie testu kuwetowego Merck 1.14761.0001","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Water Chemistry Laboratory","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(10 – 5000) μg/l"}],"search_en":"Water intended for human consumption Total iron concentration Spectrophotometric method Water and Wastewater Quality Department; Water Chemistry Laboratory Range PBL/W-03 edycja 4 wydanie z dnia 02.03.2026 r. | na podstawie testu kuwetowego Merck 1.14761.0001","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(10 – 5000) μg/l"}],"search_zh":"生活饮用水 总铁浓度 分光光度法 水与废水质量部；水化学检验室 范围 PBL/W-03 edycja 4 wydanie z dnia 02.03.2026 r. | na podstawie testu kuwetowego Merck 1.14761.0001","technique_zh":"分光光度法","test_object_zh":"生活饮用水","lab_section_zh":"水与废水质量部；水化学检验室"},{"_id":"6a7d78e60636ba417e41a3e7","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(2,2 – 50,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (2,2 – 50,0) mg/l\nMetoda spektrofotometryczna","reference":"PBL/W-05 edycja 5 wydanie z dnia 02.03.2026 r. | na podstawie testu kuwetowego Merck 1.09713.0001","norm_bases":["PBL/W-05 edycja 5 wydanie z dnia 02.03.2026 r.","na podstawie testu kuwetowego Merck 1.09713.0001"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie azotanów\nZakres (2,2 – 50,0) mg/l\nMetoda spektrofotometryczna PBL/W-05 edycja 5 wydanie z dnia 02.03.2026 r. | na podstawie testu kuwetowego Merck 1.09713.0001 Woda do spozycia przez ludzi Stezenie azotanow\nZakres (2,2 – 50,0) mg/l\nMetoda spektrofotometryczna PBL/W-05 edycja 5 wydanie z dnia 02.03.2026 r. | na podstawie testu kuwetowego Merck 1.09713.0001","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Water Chemistry Laboratory","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(2,2 – 50,0) mg/l"}],"search_en":"Water intended for human consumption Nitrate concentration Spectrophotometric method Water and Wastewater Quality Department; Water Chemistry Laboratory Range PBL/W-05 edycja 5 wydanie z dnia 02.03.2026 r. | na podstawie testu kuwetowego Merck 1.09713.0001","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(2,2 – 50,0) mg/l"}],"search_zh":"生活饮用水 硝酸盐浓度 分光光度法 水与废水质量部；水化学检验室 范围 PBL/W-05 edycja 5 wydanie z dnia 02.03.2026 r. | na podstawie testu kuwetowego Merck 1.09713.0001","technique_zh":"分光光度法","test_object_zh":"生活饮用水","lab_section_zh":"水与废水质量部；水化学检验室"},{"_id":"6a7d78e60636ba417e41a3e8","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,02 – 1,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,02 – 1,00) mg/l\nMetoda spektrofotometryczna","reference":"PBL/W-06 edycja 4 wydanie z dnia 02.03.2026 r. | na podstawie testu kuwetowego Merck 1.14776.0001","norm_bases":["PBL/W-06 edycja 4 wydanie z dnia 02.03.2026 r.","na podstawie testu kuwetowego Merck 1.14776.0001"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,02 – 1,00) mg/l\nMetoda spektrofotometryczna PBL/W-06 edycja 4 wydanie z dnia 02.03.2026 r. | na podstawie testu kuwetowego Merck 1.14776.0001 Woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,02 – 1,00) mg/l\nMetoda spektrofotometryczna PBL/W-06 edycja 4 wydanie z dnia 02.03.2026 r. | na podstawie testu kuwetowego Merck 1.14776.0001","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Water Chemistry Laboratory","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,02 – 1,00) mg/l"}],"search_en":"Water intended for human consumption Nitrite concentration Spectrophotometric method Water and Wastewater Quality Department; Water Chemistry Laboratory Range PBL/W-06 edycja 4 wydanie z dnia 02.03.2026 r. | na podstawie testu kuwetowego Merck 1.14776.0001","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 1,00) mg/l"}],"search_zh":"生活饮用水 亚硝酸盐浓度 分光光度法 水与废水质量部；水化学检验室 范围 PBL/W-06 edycja 4 wydanie z dnia 02.03.2026 r. | na podstawie testu kuwetowego Merck 1.14776.0001","technique_zh":"分光光度法","test_object_zh":"生活饮用水","lab_section_zh":"水与废水质量部；水化学检验室"},{"_id":"6a7d78e60636ba417e41a3e9","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(60 – 500) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (60 – 500) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (60 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (60 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Water Chemistry Laboratory","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(60 – 500) mg/l CaCO3"}],"search_en":"Water intended for human consumption Total content of calcium and magnesium (total hardness) Titrimetric method Water and Wastewater Quality Department; Water Chemistry Laboratory Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(60 – 500) mg/l CaCO3"}],"search_zh":"生活饮用水 钙与镁总量（总硬度） 滴定法 水与废水质量部；水化学检验室 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"生活饮用水","lab_section_zh":"水与废水质量部；水化学检验室"},{"_id":"6a7d78e60636ba417e41a3ea","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda do spozycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Water Chemistry Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Water intended for human consumption pH Potentiometric method Water and Wastewater Quality Department; Water Chemistry Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water intended for human consumption","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"生活饮用水 pH 值 电位法 水与废水质量部；水化学检验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"生活饮用水","lab_section_zh":"水与废水质量部；水化学检验室"},{"_id":"6a7d78e60636ba417e41a3eb","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(1,0 – 10) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (1,0 – 10) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Indeks nadmanganianowy\nZakres (1,0 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda do spozycia przez ludzi Indeks nadmanganianowy\nZakres (1,0 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Water Chemistry Laboratory","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(1,0 – 10) mg/l O2"}],"search_en":"Water intended for human consumption Permanganate index Titrimetric method Water and Wastewater Quality Department; Water Chemistry Laboratory Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(1,0 – 10) mg/l O2"}],"search_zh":"生活饮用水 高锰酸盐指数 滴定法 水与废水质量部；水化学检验室 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"生活饮用水","lab_section_zh":"水与废水质量部；水化学检验室"},{"_id":"6a7d78e60636ba417e41a3ec","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,06 – 2,50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,06 – 2,50) mg/l\nMetoda spektrofotometryczna","reference":"PBL/W-04 edycja 5 wydanie z dnia 02.03.2026 r. | na podstawie testu kuwetowego Merck 1.14752.0001","norm_bases":["PBL/W-04 edycja 5 wydanie z dnia 02.03.2026 r.","na podstawie testu kuwetowego Merck 1.14752.0001"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,06 – 2,50) mg/l\nMetoda spektrofotometryczna PBL/W-04 edycja 5 wydanie z dnia 02.03.2026 r. | na podstawie testu kuwetowego Merck 1.14752.0001 Woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,06 – 2,50) mg/l\nMetoda spektrofotometryczna PBL/W-04 edycja 5 wydanie z dnia 02.03.2026 r. | na podstawie testu kuwetowego Merck 1.14752.0001","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Water Chemistry Laboratory","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,06 – 2,50) mg/l"}],"search_en":"Water intended for human consumption Ammonium ion concentration Spectrophotometric method Water and Wastewater Quality Department; Water Chemistry Laboratory Range PBL/W-04 edycja 5 wydanie z dnia 02.03.2026 r. | na podstawie testu kuwetowego Merck 1.14752.0001","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,06 – 2,50) mg/l"}],"search_zh":"生活饮用水 铵离子浓度 分光光度法 水与废水质量部；水化学检验室 范围 PBL/W-04 edycja 5 wydanie z dnia 02.03.2026 r. | na podstawie testu kuwetowego Merck 1.14752.0001","technique_zh":"分光光度法","test_object_zh":"生活饮用水","lab_section_zh":"水与废水质量部；水化学检验室"},{"_id":"6a7d78e60636ba417e41a3ed","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa w 25°C","parameters":[{"name":"Zakres","range":"(100 – 2500) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa w 25°C\nZakres (100 – 2500) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Przewodność elektryczna właściwa w 25°C\nZakres (100 – 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa w 25°C\nZakres (100 – 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Water Chemistry Laboratory","methodology_en":"Electrical conductivity at 25°C","parameters_en":[{"name":"Range","range":"(100 – 2500) μS/cm"}],"search_en":"Water intended for human consumption Electrical conductivity at 25°C Conductometric method Water and Wastewater Quality Department; Water Chemistry Laboratory Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(100 – 2500) μS/cm"}],"search_zh":"生活饮用水 电导法 水与废水质量部；水化学检验室 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"生活饮用水","lab_section_zh":"水与废水质量部；水化学检验室"},{"_id":"6a7d78e60636ba417e41a3ee","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 – 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Mętność\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda do spozycia przez ludzi Metnosc\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Water Chemistry Laboratory","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,10 – 100) NTU"}],"search_en":"Water intended for human consumption Turbidity Nephelometric method Water and Wastewater Quality Department; Water Chemistry Laboratory Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 – 100) NTU"}],"search_zh":"生活饮用水 浊度 浊度法（散射法） 水与废水质量部；水化学检验室 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"生活饮用水","lab_section_zh":"水与废水质量部；水化学检验室"},{"_id":"6a7d78e60636ba417e41a3ef","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(1,00 – 15,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (1,00 – 15,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie żelaza ogólnego\nZakres (1,00 – 15,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Scieki Stezenie zelaza ogolnego\nZakres (1,00 – 15,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Water Chemistry Laboratory","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(1,00 – 15,0) mg/l"}],"search_en":"Wastewater Total iron concentration Spectrophotometric method Water and Wastewater Quality Department; Water Chemistry Laboratory Range PN-ISO 6332:2001+Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(1,00 – 15,0) mg/l"}],"search_zh":"污水 总铁浓度 分光光度法 水与废水质量部；水化学检验室 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"水与废水质量部；水化学检验室"},{"_id":"6a7d78e60636ba417e41a3f0","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura pobranej próbki ścieków"},{"name":"Zakres","range":"(5,0 – 25,0) °C"}],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (5,0 – 25,0) °C\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (5,0 – 25,0) °C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura pobranej probki sciekow\nZakres (5,0 – 25,0) °C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Wastewater Chemistry Laboratory","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature of the collected wastewater sample"},{"name":"Range","range":"(5,0 – 25,0) °C"}],"search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method Water and Wastewater Quality Department; Wastewater Chemistry Laboratory Temperature of the collected wastewater sample Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"所采废水样品的温度"},{"name":"范围","range":"(5,0 – 25,0) °C"}],"search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 水与废水质量部；废水化学实验室 所采废水样品的温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_zh":"手动法；自动法","test_object_zh":"污水","lab_section_zh":"水与废水质量部；废水化学实验室"},{"_id":"6a7d78e60636ba417e41a3f1","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Wastewater Chemistry Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Wastewater pH Potentiometric method Water and Wastewater Quality Department; Wastewater Chemistry Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"污水 pH 值 电位法 水与废水质量部；废水化学实验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"污水","lab_section_zh":"水与废水质量部；废水化学实验室"},{"_id":"6a7d78e60636ba417e41a3f2","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Wastewater Chemistry Laboratory","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 2000) mg/l"}],"search_en":"Wastewater Total suspended solids (TSS) Gravimetric method Water and Wastewater Quality Department; Wastewater Chemistry Laboratory Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 2000) mg/l"}],"search_zh":"污水 总悬浮物 重量法 水与废水质量部；废水化学实验室 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"污水","lab_section_zh":"水与废水质量部；废水化学实验室"},{"_id":"6a7d78e60636ba417e41a3f3","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie substancji ekstrahujących się eterem naftowym","parameters":[{"name":"Zakres","range":"(50 – 2500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym\nZakres (50 – 2500) mg/l\nMetoda wagowa","reference":"PBL/S-03 edycja 1 wydanie z dnia 27.02.2023 r.","norm_bases":["PBL/S-03 edycja 1 wydanie z dnia 27.02.2023 r."],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie substancji ekstrahujących się eterem naftowym\nZakres (50 – 2500) mg/l\nMetoda wagowa PBL/S-03 edycja 1 wydanie z dnia 27.02.2023 r. Scieki Stezenie substancji ekstrahujacych sie eterem naftowym\nZakres (50 – 2500) mg/l\nMetoda wagowa PBL/S-03 edycja 1 wydanie z dnia 27.02.2023 r.","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Wastewater Chemistry Laboratory","methodology_en":"Concentration of substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(50 – 2500) mg/l"}],"search_en":"Wastewater Concentration of substances extractable with petroleum ether Gravimetric method Water and Wastewater Quality Department; Wastewater Chemistry Laboratory Range PBL/S-03 edycja 1 wydanie z dnia 27.02.2023 r.","technique_en":"Gravimetric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(50 – 2500) mg/l"}],"search_zh":"污水 石油醚可萃取物浓度 重量法 水与废水质量部；废水化学实验室 范围 PBL/S-03 edycja 1 wydanie z dnia 27.02.2023 r.","technique_zh":"重量法","test_object_zh":"污水","methodology_zh":"石油醚可萃取物浓度","lab_section_zh":"水与废水质量部；废水化学实验室"},{"_id":"6a7d78e60636ba417e41a3f4","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(4 – 6000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (4 – 6000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (4 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (4 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Wastewater Chemistry Laboratory","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(4 – 6000) mg/l O2"}],"search_en":"Wastewater Biochemical oxygen demand Optical method Water and Wastewater Quality Department; Wastewater Chemistry Laboratory BOD5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Optical method","test_object_en":"Wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(4 – 6000) mg/l O2"}],"search_zh":"污水 生化需氧量 光学法 水与废水质量部；废水化学实验室 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"污水","lab_section_zh":"水与废水质量部；废水化学实验室"},{"_id":"6a7d78e60636ba417e41a3f5","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(2,0 – 6,0) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (2,0 – 6,0) mg/l O2\nMetoda optyczna","reference":"PN-EN 1899-2:2002 z wyłączeniem punktu 7.2","norm_bases":["PN-EN 1899-2:2002 z wyłączeniem punktu 7.2"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (2,0 – 6,0) mg/l O2\nMetoda optyczna PN-EN 1899-2:2002 z wyłączeniem punktu 7.2 Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (2,0 – 6,0) mg/l O2\nMetoda optyczna PN-EN 1899-2:2002 z wylaczeniem punktu 7.2","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Wastewater Chemistry Laboratory","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(2,0 – 6,0) mg/l O2"}],"search_en":"Wastewater Biochemical oxygen demand Optical method Water and Wastewater Quality Department; Wastewater Chemistry Laboratory BOD5 Range PN-EN 1899-2:2002 z wyłączeniem punktu 7.2","technique_en":"Optical method","test_object_en":"Wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(2,0 – 6,0) mg/l O2"}],"search_zh":"污水 生化需氧量 光学法 水与废水质量部；废水化学实验室 BZT5（BOD5） 范围 PN-EN 1899-2:2002 z wyłączeniem punktu 7.2","technique_zh":"光学法","test_object_zh":"污水","lab_section_zh":"水与废水质量部；废水化学实验室"},{"_id":"6a7d78e60636ba417e41a3f6","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu","parameters":[{"name":"ChZT-Cr"},{"name":"Zakres","range":"(20 – 6000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (20 – 6000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (20 – 6000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (20 – 6000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Wastewater Chemistry Laboratory","methodology_en":"Chemical oxygen demand","parameters_en":[{"name":"COD-Cr"},{"name":"Range","range":"(20 – 6000) mg/l O2"}],"search_en":"Wastewater Chemical oxygen demand Spectrophotometric method Water and Wastewater Quality Department; Wastewater Chemistry Laboratory COD-Cr Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"化学需氧量（COD-Cr）"},{"name":"范围","range":"(20 – 6000) mg/l O2"}],"search_zh":"污水 化学需氧量（COD） 分光光度法 水与废水质量部；废水化学实验室 化学需氧量（COD-Cr） 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"化学需氧量（COD）","lab_section_zh":"水与废水质量部；废水化学实验室"},{"_id":"6a7d78e60636ba417e41a3f7","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,3 – 200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,3 – 200) mg/l\nMetoda spektrofotometryczna","reference":"PBL/S-07 edycja 5 wydanie z dnia 28.02.2023 r. | na podstawie testu kuwetowego Merck 1.14543.0001; 1.14729.0001","norm_bases":["PBL/S-07 edycja 5 wydanie z dnia 28.02.2023 r.","na podstawie testu kuwetowego Merck 1.14543.0001; 1.14729.0001"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,3 – 200) mg/l\nMetoda spektrofotometryczna PBL/S-07 edycja 5 wydanie z dnia 28.02.2023 r. | na podstawie testu kuwetowego Merck 1.14543.0001; 1.14729.0001 Scieki Stezenie fosforu ogolnego\nZakres (0,3 – 200) mg/l\nMetoda spektrofotometryczna PBL/S-07 edycja 5 wydanie z dnia 28.02.2023 r. | na podstawie testu kuwetowego Merck 1.14543.0001; 1.14729.0001","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Wastewater Chemistry Laboratory","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,3 – 200) mg/l"}],"search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Water and Wastewater Quality Department; Wastewater Chemistry Laboratory Range PBL/S-07 edycja 5 wydanie z dnia 28.02.2023 r. | na podstawie testu kuwetowego Merck 1.14543.0001; 1.14729.0001","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,3 – 200) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 水与废水质量部；废水化学实验室 范围 PBL/S-07 edycja 5 wydanie z dnia 28.02.2023 r. | na podstawie testu kuwetowego Merck 1.14543.0001; 1.14729.0001","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"水与废水质量部；废水化学实验室"},{"_id":"6a7d78e60636ba417e41a3f8","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(1,0 – 150) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (1,0 – 150) mg/l\nMetoda spektrofotometryczna","reference":"PBL/S-09 edycja 3 wydanie z dnia 28.02.2023 r. | na podstawie testu kuwetowego Merck 1.14537.0001","norm_bases":["PBL/S-09 edycja 3 wydanie z dnia 28.02.2023 r.","na podstawie testu kuwetowego Merck 1.14537.0001"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego\nZakres (1,0 – 150) mg/l\nMetoda spektrofotometryczna PBL/S-09 edycja 3 wydanie z dnia 28.02.2023 r. | na podstawie testu kuwetowego Merck 1.14537.0001 Scieki Stezenie azotu ogolnego\nZakres (1,0 – 150) mg/l\nMetoda spektrofotometryczna PBL/S-09 edycja 3 wydanie z dnia 28.02.2023 r. | na podstawie testu kuwetowego Merck 1.14537.0001","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Wastewater Chemistry Laboratory","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,0 – 150) mg/l"}],"search_en":"Wastewater Total nitrogen concentration Spectrophotometric method Water and Wastewater Quality Department; Wastewater Chemistry Laboratory Range PBL/S-09 edycja 3 wydanie z dnia 28.02.2023 r. | na podstawie testu kuwetowego Merck 1.14537.0001","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 150) mg/l"}],"search_zh":"污水 总氮浓度 分光光度法 水与废水质量部；废水化学实验室 范围 PBL/S-09 edycja 3 wydanie z dnia 28.02.2023 r. | na podstawie testu kuwetowego Merck 1.14537.0001","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"水与废水质量部；废水化学实验室"},{"_id":"6a7d78e60636ba417e41a3f9","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,3 – 240) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,3 – 240) mg/l\nMetoda spektrofotometryczna","reference":"PBL/S-10 edycja 4 wydanie z dnia 28.02.2023 r. | na podstawie testu kuwetowego Merck 1.14752.0001","norm_bases":["PBL/S-10 edycja 4 wydanie z dnia 28.02.2023 r.","na podstawie testu kuwetowego Merck 1.14752.0001"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (0,3 – 240) mg/l\nMetoda spektrofotometryczna PBL/S-10 edycja 4 wydanie z dnia 28.02.2023 r. | na podstawie testu kuwetowego Merck 1.14752.0001 Scieki Stezenie azotu amonowego\nZakres (0,3 – 240) mg/l\nMetoda spektrofotometryczna PBL/S-10 edycja 4 wydanie z dnia 28.02.2023 r. | na podstawie testu kuwetowego Merck 1.14752.0001","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Wastewater Chemistry Laboratory","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,3 – 240) mg/l"}],"search_en":"Wastewater Ammonium nitrogen concentration Spectrophotometric method Water and Wastewater Quality Department; Wastewater Chemistry Laboratory Range PBL/S-10 edycja 4 wydanie z dnia 28.02.2023 r. | na podstawie testu kuwetowego Merck 1.14752.0001","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,3 – 240) mg/l"}],"search_zh":"污水 氨氮浓度 分光光度法 水与废水质量部；废水化学实验室 范围 PBL/S-10 edycja 4 wydanie z dnia 28.02.2023 r. | na podstawie testu kuwetowego Merck 1.14752.0001","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"水与废水质量部；废水化学实验室"},{"_id":"6a7d78e60636ba417e41a3fa","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenia azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,01 – 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenia azotu azotynowego\nZakres (0,01 – 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PBL/S-04 edycja 1 wydanie z dnia 07.02.2025 r. | na podstawie testu kuwetowego Merck 1.14776.0001","norm_bases":["PBL/S-04 edycja 1 wydanie z dnia 07.02.2025 r.","na podstawie testu kuwetowego Merck 1.14776.0001"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenia azotu azotynowego\nZakres (0,01 – 1,0) mg/l\nMetoda spektrofotometryczna PBL/S-04 edycja 1 wydanie z dnia 07.02.2025 r. | na podstawie testu kuwetowego Merck 1.14776.0001 Scieki Stezenia azotu azotynowego\nZakres (0,01 – 1,0) mg/l\nMetoda spektrofotometryczna PBL/S-04 edycja 1 wydanie z dnia 07.02.2025 r. | na podstawie testu kuwetowego Merck 1.14776.0001","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Wastewater Chemistry Laboratory","methodology_en":"Nitrite nitrogen concentrations","parameters_en":[{"name":"Range","range":"(0,01 – 1,0) mg/l"}],"search_en":"Wastewater Nitrite nitrogen concentrations Spectrophotometric method Water and Wastewater Quality Department; Wastewater Chemistry Laboratory Range PBL/S-04 edycja 1 wydanie z dnia 07.02.2025 r. | na podstawie testu kuwetowego Merck 1.14776.0001","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,01 – 1,0) mg/l"}],"search_zh":"污水 分光光度法 水与废水质量部；废水化学实验室 范围 PBL/S-04 edycja 1 wydanie z dnia 07.02.2025 r. | na podstawie testu kuwetowego Merck 1.14776.0001","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"水与废水质量部；废水化学实验室"},{"_id":"6a7d78e60636ba417e41a3fb","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenia azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,5 – 23,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenia azotu azotanowego\nZakres (0,5 – 23,0) mg/l\nMetoda spektrofotometryczna","reference":"PBL/S-02 edycja 1 wydanie z dnia 07.02.2025 r. | na podstawie testu kuwetowego Merck 1.09713.0001/1.09713.0002","norm_bases":["PBL/S-02 edycja 1 wydanie z dnia 07.02.2025 r.","na podstawie testu kuwetowego Merck 1.09713.0001/1.09713.0002"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenia azotu azotanowego\nZakres (0,5 – 23,0) mg/l\nMetoda spektrofotometryczna PBL/S-02 edycja 1 wydanie z dnia 07.02.2025 r. | na podstawie testu kuwetowego Merck 1.09713.0001/1.09713.0002 Scieki Stezenia azotu azotanowego\nZakres (0,5 – 23,0) mg/l\nMetoda spektrofotometryczna PBL/S-02 edycja 1 wydanie z dnia 07.02.2025 r. | na podstawie testu kuwetowego Merck 1.09713.0001/1.09713.0002","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Wastewater Chemistry Laboratory","methodology_en":"Nitrate nitrogen concentrations","parameters_en":[{"name":"Range","range":"(0,5 – 23,0) mg/l"}],"search_en":"Wastewater Nitrate nitrogen concentrations Spectrophotometric method Water and Wastewater Quality Department; Wastewater Chemistry Laboratory Range PBL/S-02 edycja 1 wydanie z dnia 07.02.2025 r. | na podstawie testu kuwetowego Merck 1.09713.0001/1.09713.0002","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,5 – 23,0) mg/l"}],"search_zh":"污水 分光光度法 水与废水质量部；废水化学实验室 范围 PBL/S-02 edycja 1 wydanie z dnia 07.02.2025 r. | na podstawie testu kuwetowego Merck 1.09713.0001/1.09713.0002","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"水与废水质量部；废水化学实验室"},{"_id":"6a7d78e60636ba417e41a3fc","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu organicznego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu organicznego (z obliczeń)","reference":"PBL/S-05 edycja 1 wydanie z dnia 07.02.2025 r.","norm_bases":["PBL/S-05 edycja 1 wydanie z dnia 07.02.2025 r."],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu organicznego (z obliczeń) PBL/S-05 edycja 1 wydanie z dnia 07.02.2025 r. Scieki Stezenie azotu organicznego (z obliczen) PBL/S-05 edycja 1 wydanie z dnia 07.02.2025 r.","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Wastewater Chemistry Laboratory","methodology_en":"Organic nitrogen concentration (calculated)","search_en":"Wastewater Organic nitrogen concentration (calculated) Water and Wastewater Quality Department; Wastewater Chemistry Laboratory PBL/S-05 edycja 1 wydanie z dnia 07.02.2025 r.","test_object_en":"Wastewater","search_zh":"污水 有机氮浓度（由计算得出） 水与废水质量部；废水化学实验室 PBL/S-05 edycja 1 wydanie z dnia 07.02.2025 r.","test_object_zh":"污水","lab_section_zh":"水与废水质量部；废水化学实验室","methodology_zh":"有机氮浓度（由计算得出）"},{"_id":"6a7d78e60636ba417e41a3fd","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie anionów chlorki (5,0 – 480) mg/l siarczany (5,0 – 250) mg/l azot azotynowy (0,015 – 1,5) mg/l azot azotanowy (0,02 – 23,0) mg/l","parameters":[],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów chlorki (5,0 – 480) mg/l siarczany (5,0 – 250) mg/l azot azotynowy (0,015 – 1,5) mg/l azot azotanowy (0,02 – 23,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie anionów chlorki (5,0 – 480) mg/l siarczany (5,0 – 250) mg/l azot azotynowy (0,015 – 1,5) mg/l azot azotanowy (0,02 – 23,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Scieki Stezenie anionow chlorki (5,0 – 480) mg/l siarczany (5,0 – 250) mg/l azot azotynowy (0,015 – 1,5) mg/l azot azotanowy (0,02 – 23,0) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Wastewater Chemistry Laboratory","methodology_en":"Anion concentrations chlorides (5,0 – 480) mg/l sulfates (5,0 – 250) mg/l nitrite nitrogen (0,015 – 1,5) mg/l nitrate nitrogen (0,02 – 23,0) mg/l","search_en":"Wastewater Anion concentrations chlorides (5,0 – 480) mg/l sulfates (5,0 – 250) mg/l nitrite nitrogen (0,015 – 1,5) mg/l nitrate nitrogen (0,02 – 23,0) mg/l Ion chromatography with conductometric detection (IC-CD) Water and Wastewater Quality Department; Wastewater Chemistry Laboratory PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Wastewater","search_zh":"污水 离子色谱-电导检测法（IC-CD） 水与废水质量部；废水化学实验室 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"污水","lab_section_zh":"水与废水质量部；废水化学实验室"},{"_id":"6a7d78e60636ba417e41a3fe","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Sucha pozostałość / zawartość wody","parameters":[{"name":"Zakres","range":"(0,2 – 93,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość / zawartość wody\nZakres (0,2 – 93,0) %\nMetoda wagowa","reference":"PN-EN 12880:2004","norm_bases":["PN-EN 12880:2004"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Sucha pozostałość / zawartość wody\nZakres (0,2 – 93,0) %\nMetoda wagowa PN-EN 12880:2004 Osady sciekowe Sucha pozostalosc / zawartosc wody\nZakres (0,2 – 93,0) %\nMetoda wagowa PN-EN 12880:2004","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Wastewater Chemistry Laboratory","methodology_en":"Dry residue / water content","parameters_en":[{"name":"Range","range":"(0,2 – 93,0) %"}],"search_en":"Sewage sludge Dry residue / water content Gravimetric method Water and Wastewater Quality Department; Wastewater Chemistry Laboratory Range PN-EN 12880:2004","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,2 – 93,0) %"}],"search_zh":"污泥 干残渣/水分含量 重量法 水与废水质量部；废水化学实验室 范围 PN-EN 12880:2004","technique_zh":"重量法","test_object_zh":"污泥","lab_section_zh":"水与废水质量部；废水化学实验室","methodology_zh":"干残渣/水分含量"},{"_id":"6a7d78e60636ba417e41a3ff","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Osady czynne","methodology":"Sucha pozostałość / zawartość wody","parameters":[{"name":"Zakres","range":"(0,2 – 93,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość / zawartość wody\nZakres (0,2 – 93,0) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02 metoda A","norm_bases":["PN-EN 15934:2013-02 metoda A"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady czynne Sucha pozostałość / zawartość wody\nZakres (0,2 – 93,0) %\nMetoda wagowa PN-EN 15934:2013-02 metoda A Osady czynne Sucha pozostalosc / zawartosc wody\nZakres (0,2 – 93,0) %\nMetoda wagowa PN-EN 15934:2013-02 metoda A","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Wastewater Chemistry Laboratory","methodology_en":"Dry residue / water content","parameters_en":[{"name":"Range","range":"(0,2 – 93,0) %"}],"search_en":"Activated sludge Dry residue / water content Gravimetric method Water and Wastewater Quality Department; Wastewater Chemistry Laboratory Range PN-EN 15934:2013-02 metoda A","technique_en":"Gravimetric method","test_object_en":"Activated sludge","parameters_zh":[{"name":"范围","range":"(0,2 – 93,0) %"}],"search_zh":"活性污泥 干残渣/水分含量 重量法 水与废水质量部；废水化学实验室 范围 PN-EN 15934:2013-02 metoda A","technique_zh":"重量法","lab_section_zh":"水与废水质量部；废水化学实验室","test_object_zh":"活性污泥","methodology_zh":"干残渣/水分含量"},{"_id":"6a7d78e60636ba417e41a400","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Osady czynne","methodology":"Straty przy prażeniu suchej masy (LOI) / Pozostałość po prażeniu","parameters":[{"name":"Zakres","range":"(2,0 - 95,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy (LOI) / Pozostałość po prażeniu\nZakres (2,0 - 95,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01 z wyłączeniem pkt 7.4 i 8.2","norm_bases":["PN-EN 15935:2022-01 z wyłączeniem pkt 7.4 i 8.2"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady czynne Straty przy prażeniu suchej masy (LOI) / Pozostałość po prażeniu\nZakres (2,0 - 95,0) %\nMetoda wagowa PN-EN 15935:2022-01 z wyłączeniem pkt 7.4 i 8.2 Osady czynne Straty przy prazeniu suchej masy (LOI) / Pozostalosc po prazeniu\nZakres (2,0 - 95,0) %\nMetoda wagowa PN-EN 15935:2022-01 z wylaczeniem pkt 7.4 i 8.2","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Wastewater Chemistry Laboratory","methodology_en":"Loss on ignition of dry matter (LOI) / Residue on ignition","parameters_en":[{"name":"Range","range":"(2,0 - 95,0) %"}],"search_en":"Activated sludge Loss on ignition of dry matter (LOI) / Residue on ignition Gravimetric method Water and Wastewater Quality Department; Wastewater Chemistry Laboratory Range PN-EN 15935:2022-01 z wyłączeniem pkt 7.4 i 8.2","technique_en":"Gravimetric method","test_object_en":"Activated sludge","parameters_zh":[{"name":"范围","range":"(2,0 - 95,0) %"}],"search_zh":"活性污泥 干物质烧失量（LOI）/ 灼烧残渣 重量法 水与废水质量部；废水化学实验室 范围 PN-EN 15935:2022-01 z wyłączeniem pkt 7.4 i 8.2","technique_zh":"重量法","lab_section_zh":"水与废水质量部；废水化学实验室","test_object_zh":"活性污泥","methodology_zh":"干物质烧失量（LOI）/ 灼烧残渣"},{"_id":"6a7d78e60636ba417e41a401","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Osady czynne","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(1000 – 15000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (1000 – 15000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady czynne Zawiesiny ogólne\nZakres (1000 – 15000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Osady czynne Zawiesiny ogolne\nZakres (1000 – 15000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Wastewater Chemistry Laboratory","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(1000 – 15000) mg/l"}],"search_en":"Activated sludge Total suspended solids (TSS) Gravimetric method Water and Wastewater Quality Department; Wastewater Chemistry Laboratory Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Activated sludge","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(1000 – 15000) mg/l"}],"search_zh":"活性污泥 总悬浮物 重量法 水与废水质量部；废水化学实验室 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","lab_section_zh":"水与废水质量部；废水化学实验室","test_object_zh":"活性污泥"},{"_id":"6a7d78e60636ba417e41a402","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Osady czynne","methodology":"Objętość względna","parameters":[{"name":"Zakres","range":"(100 – 1000) ml/l"}],"technique":"Metoda objętościowa","techniques":["Metoda objętościowa"],"computed":[],"activity":"Objętość względna\nZakres (100 – 1000) ml/l\nMetoda objętościowa","reference":"PN-EN 14702-1:2008","norm_bases":["PN-EN 14702-1:2008"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady czynne Objętość względna\nZakres (100 – 1000) ml/l\nMetoda objętościowa PN-EN 14702-1:2008 Osady czynne Objetosc wzgledna\nZakres (100 – 1000) ml/l\nMetoda objetosciowa PN-EN 14702-1:2008","categories":["water"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Wastewater Chemistry Laboratory","methodology_en":"Relative volume","parameters_en":[{"name":"Range","range":"(100 – 1000) ml/l"}],"search_en":"Activated sludge Relative volume Volumetric method Water and Wastewater Quality Department; Wastewater Chemistry Laboratory Range PN-EN 14702-1:2008","technique_en":"Volumetric method","test_object_en":"Activated sludge","parameters_zh":[{"name":"范围","range":"(100 – 1000) ml/l"}],"search_zh":"活性污泥 相对体积 容量法 水与废水质量部；废水化学实验室 范围 PN-EN 14702-1:2008","technique_zh":"容量法","lab_section_zh":"水与废水质量部；废水化学实验室","test_object_zh":"活性污泥","methodology_zh":"相对体积"},{"_id":"6a7d78e60636ba417e41a403","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Osady czynne","methodology":"Indeks objętościowy (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks objętościowy (z obliczeń)","reference":"PN-EN 14702-1:2008","norm_bases":["PN-EN 14702-1:2008"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady czynne Indeks objętościowy (z obliczeń) PN-EN 14702-1:2008 Osady czynne Indeks objetosciowy (z obliczen) PN-EN 14702-1:2008","categories":["water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Wastewater Chemistry Laboratory","methodology_en":"Volume index (calculated)","search_en":"Activated sludge Volume index (calculated) Water and Wastewater Quality Department; Wastewater Chemistry Laboratory PN-EN 14702-1:2008","test_object_en":"Activated sludge","lab_section_zh":"水与废水质量部；废水化学实验室","search_zh":"活性污泥 水与废水质量部；废水化学实验室 PN-EN 14702-1:2008","test_object_zh":"活性污泥"},{"_id":"6a7d78e60636ba417e41a404","lab_id":"69ad52a3de79e566650fb5c4","country":"PL","accr_number":"AB 1128","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie anionów","parameters":[{"name":"chlorki","range":"(5,0 – 250) mg/l"},{"name":"siarczany","range":"(5,0 – 250) mg/l"},{"name":"azotany","range":"(0,10 – 50,0) mg/l"},{"name":"azotyny","range":"(0,05 – 5,0) mg/l"},{"name":"fluorki","range":"(0,10 – 5,0) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nchlorki (5,0 – 250) mg/l\nsiarczany (5,0 – 250) mg/l\nazotany (0,10 – 50,0) mg/l\nazotyny (0,05 – 5,0) mg/l\nfluorki (0,10 – 5,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Dział Jakości Wody i Ścieków; Pracownia Chemii Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie anionów\nZakres:\nchlorki (5,0 – 250) mg/l\nsiarczany (5,0 – 250) mg/l\nazotany (0,10 – 50,0) mg/l\nazotyny (0,05 – 5,0) mg/l\nfluorki (0,10 – 5,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda do spozycia przez ludzi Stezenie anionow\nZakres:\nchlorki (5,0 – 250) mg/l\nsiarczany (5,0 – 250) mg/l\nazotany (0,10 – 50,0) mg/l\nazotyny (0,05 – 5,0) mg/l\nfluorki (0,10 – 5,0) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Quality Department; Wastewater Chemistry Laboratory","methodology_en":"Anion concentrations","parameters_en":[{"name":"chlorides","range":"(5,0 – 250) mg/l"},{"name":"sulfates","range":"(5,0 – 250) mg/l"},{"name":"nitrates","range":"(0,10 – 50,0) mg/l"},{"name":"nitrites","range":"(0,05 – 5,0) mg/l"},{"name":"fluorides","range":"(0,10 – 5,0) mg/l"}],"search_en":"Water intended for human consumption Anion concentrations Ion chromatography with conductometric detection (IC-CD) Water and Wastewater Quality Department; Wastewater Chemistry Laboratory chlorides sulfates nitrates nitrites fluorides PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water intended for human consumption","methodology_zh":"阴离子浓度","search_zh":"生活饮用水 阴离子浓度 离子色谱-电导检测法（IC-CD） 水与废水质量部；废水化学实验室 氯化物 硫酸盐 硝酸盐 亚硝酸盐 氟化物 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"生活饮用水","parameters_zh":[{"name":"氯化物","range":"(5,0 – 250) mg/l"},{"name":"硫酸盐","range":"(5,0 – 250) mg/l"},{"name":"硝酸盐","range":"(0,10 – 50,0) mg/l"},{"name":"亚硝酸盐","range":"(0,05 – 5,0) mg/l"},{"name":"氟化物","range":"(0,10 – 5,0) mg/l"}],"lab_section_zh":"水与废水质量部；废水化学实验室"}],"has_pdf":true}