{"lab":{"_id":"69ad52a3de79e566650fb5be","accr_number":"AB 1125","country":"PL","accr_body":"PCA","address":"ul. Złota 59, 00-120 Warszawa, PGE ENERGIA CIEPŁA S.A. ODDZIAŁ WYBRZEŻE W GDAŃSKU, ul. Swojska 9","categories":["petro","water","environment"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":20,"name":"PGE ENERGIA CIEPŁA S.A.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1125.pdf"],"scope_summary":"","search_text":"pge energia ciepła s.a. ul. złota 59, 00-120 warszawa, pge energia ciepła s.a. oddział wybrzeże w gdańsku, ul. swojska 9 materials petro other pharma environment water","status":"active","updated_at":"2026-03-08T14:50:18.170Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:18.170Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201125,podmiot.html","parse_date":"2026-07-17T16:18:52.837Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"C/10; C/32","pl":"Badania chemiczne paliw stałych i odpadów","en":"Chemical tests of solid fuels and wastes"},{"codes":"N/10","pl":"Badania właściwości fizycznych paliw stałych","en":"Tests of physical properties of solid fuels"},{"codes":"C/30/P; N/30/P","pl":"Badania chemiczne, właściwości fizycznych i pobieranie próbek ścieków","en":"Chemical tests, tests of physical properties and sampling of sewage"}],"issue":{"no":"22","date":"21.01.2026"},"map_coord":[52.230071,21.002445],"map_geo":"nominatim-street","has_en":true,"category_counts":{"petro":13,"water":6,"environment":1},"category_scores":{"petro":8.45,"water":1.8,"environment":0.05},"has_zh":true},"methods":[{"_id":"6a5a55ec9af9f73f382501c4","lab_id":"69ad52a3de79e566650fb5be","country":"PL","accr_number":"AB 1125","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci pierwszego stopnia (wilgoć przemijająca) Zakres: (2,0 – 20,0)% Metoda wagowa","methodology_en":"First-stage moisture content (transient moisture) Range: (2,0 – 20,0)% Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci pierwszego stopnia (wilgoć przemijająca) Zakres: (2,0 – 20,0)% Metoda wagowa","reference":"PN-ISO 589:2006 metoda A1 PN-80/G-04511","norm_bases":["PN-ISO 589:2006 metoda A1 PN-80/G-04511"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci pierwszego stopnia (wilgoć przemijająca) Zakres: (2,0 – 20,0)% Metoda wagowa PN-ISO 589:2006 metoda A1 PN-80/G-04511 Paliwa stale: wegiel kamienny Zawartosc wilgoci pierwszego stopnia (wilgoc przemijajaca) Zakres: (2,0 – 20,0)% Metoda wagowa PN-ISO 589:2006 metoda A1 PN-80/G-04511","categories":["petro"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal First-stage moisture content (transient moisture) Range: (2,0 – 20,0)% Gravimetric method PN-ISO 589:2006 metoda A1 PN-80/G-04511","search_zh":"固体燃料：烟煤 PN-ISO 589:2006 metoda A1 PN-80/G-04511","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ec9af9f73f382501c5","lab_id":"69ad52a3de79e566650fb5be","country":"PL","accr_number":"AB 1125","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci w węglu powietrznosuchym Zakres: (0,5 – 12,0)% Metoda wagowa","methodology_en":"Moisture content in air-dry coal Range: (0,5 – 12,0)% Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci w węglu powietrznosuchym Zakres: (0,5 – 12,0)% Metoda wagowa","reference":"PN-80/G-04511","norm_bases":["PN-80/G-04511"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w węglu powietrznosuchym Zakres: (0,5 – 12,0)% Metoda wagowa PN-80/G-04511 Paliwa stale: wegiel kamienny Zawartosc wilgoci w weglu powietrznosuchym Zakres: (0,5 – 12,0)% Metoda wagowa PN-80/G-04511","categories":["petro"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Moisture content in air-dry coal Range: (0,5 – 12,0)% Gravimetric method PN-80/G-04511","search_zh":"固体燃料：烟煤 PN-80/G-04511","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ec9af9f73f382501c6","lab_id":"69ad52a3de79e566650fb5be","country":"PL","accr_number":"AB 1125","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci drugiego stopnia Zakres: (0,5 – 12,0)% Metoda wagowa","methodology_en":"Second-stage moisture content Range: (0,5 – 12,0)% Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci drugiego stopnia Zakres: (0,5 – 12,0)% Metoda wagowa","reference":"PN-ISO 589:2006 metoda A1","norm_bases":["PN-ISO 589:2006 metoda A1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci drugiego stopnia Zakres: (0,5 – 12,0)% Metoda wagowa PN-ISO 589:2006 metoda A1 Paliwa stale: wegiel kamienny Zawartosc wilgoci drugiego stopnia Zakres: (0,5 – 12,0)% Metoda wagowa PN-ISO 589:2006 metoda A1","categories":["petro"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Second-stage moisture content Range: (0,5 – 12,0)% Gravimetric method PN-ISO 589:2006 metoda A1","search_zh":"固体燃料：烟煤 PN-ISO 589:2006 metoda A1","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ec9af9f73f382501c7","lab_id":"69ad52a3de79e566650fb5be","country":"PL","accr_number":"AB 1125","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci w próbce analitycznej Zakres: (0,5 – 12,0)% Metoda wagowa","methodology_en":"Moisture content in the analytical sample Range: (0,5 – 12,0)% Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej Zakres: (0,5 – 12,0)% Metoda wagowa","reference":"PN-80/G-04511 PN-ISO 11722:2009","norm_bases":["PN-80/G-04511 PN-ISO 11722:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej Zakres: (0,5 – 12,0)% Metoda wagowa PN-80/G-04511 PN-ISO 11722:2009 Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej Zakres: (0,5 – 12,0)% Metoda wagowa PN-80/G-04511 PN-ISO 11722:2009","categories":["petro"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Moisture content in the analytical sample Range: (0,5 – 12,0)% Gravimetric method PN-80/G-04511 PN-ISO 11722:2009","search_zh":"固体燃料：烟煤 PN-80/G-04511 PN-ISO 11722:2009","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ec9af9f73f382501c8","lab_id":"69ad52a3de79e566650fb5be","country":"PL","accr_number":"AB 1125","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci całkowitej (z obliczeń)","methodology_en":"Total moisture content (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej (z obliczeń)","reference":"PN-80/G-04511 PN-ISO 589:2006 metoda A1","norm_bases":["PN-80/G-04511 PN-ISO 589:2006 metoda A1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej (z obliczeń) PN-80/G-04511 PN-ISO 589:2006 metoda A1 Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej (z obliczen) PN-80/G-04511 PN-ISO 589:2006 metoda A1","categories":["petro"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Total moisture content (calculated) PN-80/G-04511 PN-ISO 589:2006 metoda A1","search_zh":"固体燃料：烟煤 全水分含量（计算值） PN-80/G-04511 PN-ISO 589:2006 metoda A1","test_object_zh":"固体燃料：烟煤","methodology_zh":"全水分含量（计算值）"},{"_id":"6a5a55ec9af9f73f382501c9","lab_id":"69ad52a3de79e566650fb5be","country":"PL","accr_number":"AB 1125","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość popiołu Zakres: (3,0 – 40,0)% Metoda wagowa","methodology_en":"Ash content Range: (3,0 – 40,0)% Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość popiołu Zakres: (3,0 – 40,0)% Metoda wagowa","reference":"PN-ISO 1171:2002","norm_bases":["PN-ISO 1171:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu Zakres: (3,0 – 40,0)% Metoda wagowa PN-ISO 1171:2002 Paliwa stale: wegiel kamienny Zawartosc popiolu Zakres: (3,0 – 40,0)% Metoda wagowa PN-ISO 1171:2002","categories":["petro"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Ash content Range: (3,0 – 40,0)% Gravimetric method PN-ISO 1171:2002","search_zh":"固体燃料：烟煤 PN-ISO 1171:2002","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ec9af9f73f382501ca","lab_id":"69ad52a3de79e566650fb5be","country":"PL","accr_number":"AB 1125","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość siarki całkowitej Zakres: (0,10 – 2,00 )% Metoda wysokotemperaturowego spalania z detekcją IR","methodology_en":"Total sulphur content Range: (0,10 – 2,00 )% High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej Zakres: (0,10 – 2,00 )% Metoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001 z wyłączeniem p. 3 ISO 19579:2006","norm_bases":["PN-G-04584:2001 z wyłączeniem p. 3 ISO 19579:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość siarki całkowitej Zakres: (0,10 – 2,00 )% Metoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 z wyłączeniem p. 3 ISO 19579:2006 Paliwa stale: wegiel kamienny Zawartosc siarki calkowitej Zakres: (0,10 – 2,00 )% Metoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001 z wylaczeniem p. 3 ISO 19579:2006","categories":["petro"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Total sulphur content Range: (0,10 – 2,00 )% High-temperature combustion method with IR detection PN-G-04584:2001 z wyłączeniem p. 3 ISO 19579:2006","search_zh":"固体燃料：烟煤 PN-G-04584:2001 z wyłączeniem p. 3 ISO 19579:2006","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ec9af9f73f382501cb","lab_id":"69ad52a3de79e566650fb5be","country":"PL","accr_number":"AB 1125","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość węgla całkowitego Zakres: (40,0 – 90,0)% Metoda wysokotemperaturowego spalania z detekcją IR","methodology_en":"Total carbon content Range: (40,0 – 90,0)% High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego Zakres: (40,0 – 90,0)% Metoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość węgla całkowitego Zakres: (40,0 – 90,0)% Metoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc wegla calkowitego Zakres: (40,0 – 90,0)% Metoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Total carbon content Range: (40,0 – 90,0)% High-temperature combustion method with IR detection PN-G-04571:1998","search_zh":"固体燃料：烟煤 PN-G-04571:1998","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ec9af9f73f382501cc","lab_id":"69ad52a3de79e566650fb5be","country":"PL","accr_number":"AB 1125","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wodoru całkowitego Zakres: (3,00 – 5,50 )% Metoda wysokotemperaturowego spalania z detekcją IR","methodology_en":"Total hydrogen content Range: (3,00 – 5,50 )% High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wodoru całkowitego Zakres: (3,00 – 5,50 )% Metoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wodoru całkowitego Zakres: (3,00 – 5,50 )% Metoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc wodoru calkowitego Zakres: (3,00 – 5,50 )% Metoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Total hydrogen content Range: (3,00 – 5,50 )% High-temperature combustion method with IR detection PN-G-04571:1998","search_zh":"固体燃料：烟煤 PN-G-04571:1998","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ec9af9f73f382501cd","lab_id":"69ad52a3de79e566650fb5be","country":"PL","accr_number":"AB 1125","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość części lotnych Zakres: (25,00 – 40,00)% Metoda wagowa","methodology_en":"Volatile matter content Range: (25,00 – 40,00)% Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość części lotnych Zakres: (25,00 – 40,00)% Metoda wagowa","reference":"PN-G-04516:1998","norm_bases":["PN-G-04516:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość części lotnych Zakres: (25,00 – 40,00)% Metoda wagowa PN-G-04516:1998 Paliwa stale: wegiel kamienny Zawartosc czesci lotnych Zakres: (25,00 – 40,00)% Metoda wagowa PN-G-04516:1998","categories":["petro"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Volatile matter content Range: (25,00 – 40,00)% Gravimetric method PN-G-04516:1998","search_zh":"固体燃料：烟煤 PN-G-04516:1998","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ec9af9f73f382501ce","lab_id":"69ad52a3de79e566650fb5be","country":"PL","accr_number":"AB 1125","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci w próbce analitycznej Zakres (0,50 – 12,00)% Metoda termograwimetryczna TGA","methodology_en":"Moisture content in the analytical sample Range (0,50 – 12,00)% Thermogravimetric method TGA","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej Zakres (0,50 – 12,00)% Metoda termograwimetryczna TGA","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej Zakres (0,50 – 12,00)% Metoda termograwimetryczna TGA PN-G-04560:1998 Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej Zakres (0,50 – 12,00)% Metoda termograwimetryczna TGA PN-G-04560:1998","categories":["petro"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Moisture content in the analytical sample Range (0,50 – 12,00)% Thermogravimetric method TGA PN-G-04560:1998","search_zh":"固体燃料：烟煤 PN-G-04560:1998","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ec9af9f73f382501cf","lab_id":"69ad52a3de79e566650fb5be","country":"PL","accr_number":"AB 1125","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość popiołu Zakres (3,00 – 40,00)% Metoda termograwimetryczna TGA","methodology_en":"Ash content Range (3,00 – 40,00)% Thermogravimetric method TGA","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość popiołu Zakres (3,00 – 40,00)% Metoda termograwimetryczna TGA","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu Zakres (3,00 – 40,00)% Metoda termograwimetryczna TGA PN-G-04560:1998 Paliwa stale: wegiel kamienny Zawartosc popiolu Zakres (3,00 – 40,00)% Metoda termograwimetryczna TGA PN-G-04560:1998","categories":["petro"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Ash content Range (3,00 – 40,00)% Thermogravimetric method TGA PN-G-04560:1998","search_zh":"固体燃料：烟煤 PN-G-04560:1998","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ec9af9f73f382501d0","lab_id":"69ad52a3de79e566650fb5be","country":"PL","accr_number":"AB 1125","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Ciepło spalania Zakres: (13956 – 34890) kJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń)","methodology_en":"Gross calorific value Range: (13956 – 34890) kJ/kg Calorimetric method Net calorific value (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciepło spalania Zakres: (13956 – 34890) kJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń)","reference":"PN-81/G-04513 PN-ISO 1928:2020-05","norm_bases":["PN-81/G-04513 PN-ISO 1928:2020-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Ciepło spalania Zakres: (13956 – 34890) kJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń) PN-81/G-04513 PN-ISO 1928:2020-05 Paliwa stale: wegiel kamienny Cieplo spalania Zakres: (13956 – 34890) kJ/kg Metoda kalorymetryczna Wartosc opalowa (z obliczen) PN-81/G-04513 PN-ISO 1928:2020-05","categories":["petro"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Gross calorific value Range: (13956 – 34890) kJ/kg Calorimetric method Net calorific value (calculated) PN-81/G-04513 PN-ISO 1928:2020-05","search_zh":"固体燃料：烟煤 PN-81/G-04513 PN-ISO 1928:2020-05","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ec9af9f73f382501d1","lab_id":"69ad52a3de79e566650fb5be","country":"PL","accr_number":"AB 1125","accr_body":"PCA","test_object":"OdpadyO): kod 10 01 01, 10 01 02","test_object_en":"WasteO): code 10 01 01, 10 01 02","methodology":"Zawartość węgla całkowitego Zakres: (1,0 – 40,0) % Metoda wysokotemperaturowego spalania z detekcją IR","methodology_en":"Total carbon content Range: (1,0 – 40,0) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego Zakres: (1,0 – 40,0) % Metoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"OdpadyO): kod 10 01 01, 10 01 02 Zawartość węgla całkowitego Zakres: (1,0 – 40,0) % Metoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 OdpadyO): kod 10 01 01, 10 01 02 Zawartosc wegla calkowitego Zakres: (1,0 – 40,0) % Metoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["environment"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"WasteO): code 10 01 01, 10 01 02 Total carbon content Range: (1,0 – 40,0) % High-temperature combustion method with IR detection PN-G-04571:1998"},{"_id":"6a5a55ec9af9f73f382501d2","lab_id":"69ad52a3de79e566650fb5be","country":"PL","accr_number":"AB 1125","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Metoda automatyczna Metoda manualna Temperatura ścieków/pobranej próbki ścieków Zakres (3,0 – 45,0) ⁰C","methodology_en":"Sampling for chemical and physical testing Automatic method Manual method Temperature of wastewater/of the wastewater sample taken Range (3,0 – 45,0) ⁰C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Metoda automatyczna Metoda manualna Temperatura ścieków/pobranej próbki ścieków Zakres (3,0 – 45,0) ⁰C","reference":"PN-ISO 5667-10:2021-11 PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11 PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych Metoda automatyczna Metoda manualna Temperatura ścieków/pobranej próbki ścieków Zakres (3,0 – 45,0) ⁰C PN-ISO 5667-10:2021-11 PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych Metoda automatyczna Metoda manualna Temperatura sciekow/pobranej probki sciekow Zakres (3,0 – 45,0) ⁰C PN-ISO 5667-10:2021-11 PN-77/C-04584","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Sampling for chemical and physical testing Automatic method Manual method Temperature of wastewater/of the wastewater sample taken Range (3,0 – 45,0) ⁰C PN-ISO 5667-10:2021-11 PN-77/C-04584","search_zh":"污水 PN-ISO 5667-10:2021-11 PN-77/C-04584","test_object_zh":"污水"},{"_id":"6a5a55ec9af9f73f382501d3","lab_id":"69ad52a3de79e566650fb5be","country":"PL","accr_number":"AB 1125","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"pH Zakres: 4,0 – 10,0 Metoda potencjometryczna","methodology_en":"pH Range: 4,0 – 10,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 4,0 – 10,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki pH Zakres: 4,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH Zakres: 4,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater pH Range: 4,0 – 10,0 Potentiometric method PN-EN ISO 10523:2012","search_zh":"污水 pH 范围：4,0 – 10,0 电位法 PN-EN ISO 10523:2012","test_object_zh":"污水","methodology_zh":"pH 范围：4,0 – 10,0 电位法"},{"_id":"6a5a55ec9af9f73f382501d4","lab_id":"69ad52a3de79e566650fb5be","country":"PL","accr_number":"AB 1125","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Zawiesiny ogólne Zakres: (2,00 – 50,0) mg/l Metoda wagowa","methodology_en":"Total suspended solids Range: (2,00 – 50,0) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: (2,00 – 50,0) mg/l Metoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Zawiesiny ogólne Zakres: (2,00 – 50,0) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne Zakres: (2,00 – 50,0) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Total suspended solids Range: (2,00 – 50,0) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007","search_zh":"污水 PN-EN 872:2007+Ap1:2007","test_object_zh":"污水"},{"_id":"6a5a55ec9af9f73f382501d5","lab_id":"69ad52a3de79e566650fb5be","country":"PL","accr_number":"AB 1125","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu ogólnego Zakres: (10 – 3000) mg/l Metoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną","methodology_en":"Total nitrogen concentration Range: (10 – 3000) mg/l High temperature combustion with chemiluminescence detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego Zakres: (10 – 3000) mg/l Metoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną","reference":"PN-EN ISO 20236:2025-05","norm_bases":["PN-EN ISO 20236:2025-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu ogólnego Zakres: (10 – 3000) mg/l Metoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną PN-EN ISO 20236:2025-05 Scieki Stezenie azotu ogolnego Zakres: (10 – 3000) mg/l Metoda wysokotemperaturowego spalania z detekcja chemiluminescencyjna PN-EN ISO 20236:2025-05","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Total nitrogen concentration Range: (10 – 3000) mg/l High temperature combustion with chemiluminescence detection PN-EN ISO 20236:2025-05","search_zh":"污水 PN-EN ISO 20236:2025-05","test_object_zh":"污水"},{"_id":"6a5a55ec9af9f73f382501d6","lab_id":"69ad52a3de79e566650fb5be","country":"PL","accr_number":"AB 1125","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie anionów Zakres: chlorki (1,0 – 30000) mg/l siarczany (1,0 – 5000) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","methodology_en":"Anion concentrations Range: chlorides (1,0 – 30000) mg/l sulfates (1,0 – 5000) mg/l Ion chromatography with conductometric detection (IC-CD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie anionów Zakres: chlorki (1,0 – 30000) mg/l siarczany (1,0 – 5000) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie anionów Zakres: chlorki (1,0 – 30000) mg/l siarczany (1,0 – 5000) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Scieki Stezenie anionow Zakres: chlorki (1,0 – 30000) mg/l siarczany (1,0 – 5000) mg/l Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Anion concentrations Range: chlorides (1,0 – 30000) mg/l sulfates (1,0 – 5000) mg/l Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","search_zh":"污水 PN-EN ISO 10304-1:2009+AC:2012","test_object_zh":"污水"},{"_id":"6a5a55ec9af9f73f382501d7","lab_id":"69ad52a3de79e566650fb5be","country":"PL","accr_number":"AB 1125","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie rtęci Zakres: (0,00010 – 0,02) mg/l (0,10 – 20) µg/l Metoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CVAFS)","methodology_en":"Mercury concentration Range: (0,00010 – 0,02) mg/l (0,10 – 20) µg/l Cold vapour atomic fluorescence spectrometry method (CVAFS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie rtęci Zakres: (0,00010 – 0,02) mg/l (0,10 – 20) µg/l Metoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CVAFS)","reference":"PN-EN ISO 17852:2009","norm_bases":["PN-EN ISO 17852:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie rtęci Zakres: (0,00010 – 0,02) mg/l (0,10 – 20) µg/l Metoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CVAFS) PN-EN ISO 17852:2009 Scieki Stezenie rteci Zakres: (0,00010 – 0,02) mg/l (0,10 – 20) µg/l Metoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CVAFS) PN-EN ISO 17852:2009","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Mercury concentration Range: (0,00010 – 0,02) mg/l (0,10 – 20) µg/l Cold vapour atomic fluorescence spectrometry method (CVAFS) PN-EN ISO 17852:2009","search_zh":"污水 PN-EN ISO 17852:2009","test_object_zh":"污水"}],"has_pdf":true}