{"lab":{"_id":"69ad52a3de79e566650fb5b8","accr_number":"AB 1120","country":"PL","accr_body":"PCA","address":"ul. Warszawska 27, 15-062 Białystok, ODDZIAŁ ELEKTROCIEPŁOWNIA BIAŁYSTOK Z SIEDZIBĄ W BIAŁYMSTOKU, WYDZIAŁ LABORATORIUM, ul. Gen. Władysława Andersa 15","categories":["petro","environment"],"city":"Białystok","imported_at":"2026-03-08T10:42:43.265Z","methods_count":24,"name":"ENEA CIEPŁO SP. Z O.O.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1120.pdf"],"scope_summary":"","search_text":"enea ciepło sp. z o.o. ul. warszawska 27, 15-062 białystok, oddział elektrociepłownia białystok z siedzibą w białymstoku, wydział laboratorium, ul. gen. władysława andersa 15 materials petro other pharma environment food","status":"active","updated_at":"2026-03-08T14:50:17.969Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-14T13:33:40.812Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201120,podmiot.html","parse_date":"2026-08-14T13:33:40.812Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"C/10; C/32","pl":"Badania chemiczne paliw stałych, paliw ciekłych, odpadów","en":"Chemical tests of solid fuels, liquid fuels, waste"},{"codes":"N/10; N/32","pl":"Badania właściwości fizycznych paliw stałych, paliw ciekłych, odpadów","en":"Tests of physical properties of solid fuels, liquid fuels, waste"}],"issue":{"no":"28","date":"01.07.2026"},"map_coord":[53.132747,23.171608],"map_geo":"nominatim-street","lab_locations":[{"name":"Wydział Laboratorium","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/14/6a93e3e4e5293676ce9a52675000904a/AB%201120.pdf","has_en":true,"category_counts":{"petro":22,"environment":2},"category_scores":{"petro":20.17,"environment":0.17},"has_zh":true},"methods":[{"_id":"6a7f1934bc25eed9be28d826","lab_id":"69ad52a3de79e566650fb5b8","country":"PL","accr_number":"AB 1120","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci pierwszego stopnia","parameters":[{"name":"Zakres","range":"(1,0 – 20,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci pierwszego stopnia\nZakres (1,0 – 20,0) %\nMetoda wagowa","reference":"PN-ISO 589:2006","norm_bases":["PN-ISO 589:2006"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci pierwszego stopnia\nZakres (1,0 – 20,0) %\nMetoda wagowa PN-ISO 589:2006 Paliwa stale: wegiel kamienny Zawartosc wilgoci pierwszego stopnia\nZakres (1,0 – 20,0) %\nMetoda wagowa PN-ISO 589:2006","categories":["petro"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"First-stage moisture content","parameters_en":[{"name":"Range","range":"(1,0 – 20,0) %"}],"search_en":"Solid fuels: hard coal First-stage moisture content Gravimetric method Range PN-ISO 589:2006","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(1,0 – 20,0) %"}],"search_zh":"固体燃料：烟煤 重量法 范围 PN-ISO 589:2006","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a7f1934bc25eed9be28d827","lab_id":"69ad52a3de79e566650fb5b8","country":"PL","accr_number":"AB 1120","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci drugiego stopnia","parameters":[{"name":"Zakres","range":"(1,0 – 11,0) %"},{"name":"Wilgoć całkowita (z obliczeń)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci drugiego stopnia\nZakres:\nZakres (1,0 – 11,0) %\nWilgoć całkowita (z obliczeń)\nMetoda wagowa","reference":"PN-ISO 589:2006 Metoda A1","norm_bases":["PN-ISO 589:2006 Metoda A1"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci drugiego stopnia\nZakres:\nZakres (1,0 – 11,0) %\nWilgoć całkowita (z obliczeń)\nMetoda wagowa PN-ISO 589:2006 Metoda A1 Paliwa stale: wegiel kamienny Zawartosc wilgoci drugiego stopnia\nZakres:\nZakres (1,0 – 11,0) %\nWilgoc calkowita (z obliczen)\nMetoda wagowa PN-ISO 589:2006 Metoda A1","categories":["petro"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Second-stage moisture content","parameters_en":[{"name":"Range","range":"(1,0 – 11,0) %"},{"name":"Total moisture (calculated)"}],"search_en":"Solid fuels: hard coal Second-stage moisture content Gravimetric method Range Total moisture (calculated) PN-ISO 589:2006 Metoda A1","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(1,0 – 11,0) %"},{"name":"Wilgoć całkowita (z obliczeń)"}],"search_zh":"固体燃料：烟煤 第二阶段水分含量 重量法 范围 PN-ISO 589:2006 Metoda A1","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"第二阶段水分含量"},{"_id":"6a7f1934bc25eed9be28d828","lab_id":"69ad52a3de79e566650fb5b8","country":"PL","accr_number":"AB 1120","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(1,0 – 11,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (1,0 – 11,0) %\nMetoda wagowa","reference":"PN-ISO 11722:2009","norm_bases":["PN-ISO 11722:2009"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej\nZakres (1,0 – 11,0) %\nMetoda wagowa PN-ISO 11722:2009 Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej\nZakres (1,0 – 11,0) %\nMetoda wagowa PN-ISO 11722:2009","categories":["petro"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(1,0 – 11,0) %"}],"search_en":"Solid fuels: hard coal Moisture content in the analytical sample Gravimetric method Range PN-ISO 11722:2009","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 11,0) %"}],"search_zh":"固体燃料：烟煤 分析样品水分含量 重量法 范围 PN-ISO 11722:2009","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a7f1934bc25eed9be28d829","lab_id":"69ad52a3de79e566650fb5b8","country":"PL","accr_number":"AB 1120","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(2,0 – 40,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu\nZakres (2,0 – 40,0) %\nMetoda wagowa","reference":"PN-ISO 1171:2002","norm_bases":["PN-ISO 1171:2002"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu\nZakres (2,0 – 40,0) %\nMetoda wagowa PN-ISO 1171:2002 Paliwa stale: wegiel kamienny Zawartosc popiolu\nZakres (2,0 – 40,0) %\nMetoda wagowa PN-ISO 1171:2002","categories":["petro"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(2,0 – 40,0) %"}],"search_en":"Solid fuels: hard coal Ash content Gravimetric method Range PN-ISO 1171:2002","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(2,0 – 40,0) %"}],"search_zh":"固体燃料：烟煤 灰分含量 重量法 范围 PN-ISO 1171:2002","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a7f1934bc25eed9be28d82a","lab_id":"69ad52a3de79e566650fb5b8","country":"PL","accr_number":"AB 1120","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,10 – 2,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,10 – 2,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"ISO 19579:2006","norm_bases":["ISO 19579:2006"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość siarki całkowitej\nZakres (0,10 – 2,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR ISO 19579:2006 Paliwa stale: wegiel kamienny Zawartosc siarki calkowitej\nZakres (0,10 – 2,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR ISO 19579:2006","categories":["petro"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,10 – 2,00) %"}],"search_en":"Solid fuels: hard coal Total sulfur content High-temperature combustion with IR detection Range ISO 19579:2006","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,10 – 2,00) %"}],"search_zh":"固体燃料：烟煤 全硫含量 高温燃烧红外检测法 范围 ISO 19579:2006","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a7f1934bc25eed9be28d82b","lab_id":"69ad52a3de79e566650fb5b8","country":"PL","accr_number":"AB 1120","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wodoru","parameters":[{"name":"Zakres","range":"(3,00 – 5,50) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość wodoru\nZakres (3,00 – 5,50) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"ISO 29541:2025","norm_bases":["ISO 29541:2025"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wodoru\nZakres (3,00 – 5,50) %\nMetoda wysokotemperaturowego spalania z detekcją IR ISO 29541:2025 Paliwa stale: wegiel kamienny Zawartosc wodoru\nZakres (3,00 – 5,50) %\nMetoda wysokotemperaturowego spalania z detekcja IR ISO 29541:2025","categories":["petro"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen content","parameters_en":[{"name":"Range","range":"(3,00 – 5,50) %"}],"search_en":"Solid fuels: hard coal Hydrogen content High-temperature combustion with IR detection Range ISO 29541:2025","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(3,00 – 5,50) %"}],"search_zh":"固体燃料：烟煤 氢含量 高温燃烧红外检测法 范围 ISO 29541:2025","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤","methodology_zh":"氢含量"},{"_id":"6a7f1934bc25eed9be28d82c","lab_id":"69ad52a3de79e566650fb5b8","country":"PL","accr_number":"AB 1120","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(20000 – 34000) J/g"},{"name":"Wartość opałowa (z obliczeń)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres:\nZakres (20000 – 34000) J/g\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-ISO 1928:2020-05","norm_bases":["PN-ISO 1928:2020-05"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Ciepło spalania\nZakres:\nZakres (20000 – 34000) J/g\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-ISO 1928:2020-05 Paliwa stale: wegiel kamienny Cieplo spalania\nZakres:\nZakres (20000 – 34000) J/g\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-ISO 1928:2020-05","categories":["petro"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(20000 – 34000) J/g"},{"name":"Net calorific value (calculated)"}],"search_en":"Solid fuels: hard coal Gross calorific value Calorimetric method Range Net calorific value (calculated) PN-ISO 1928:2020-05","technique_en":"Calorimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(20000 – 34000) J/g"},{"name":"低位发热量（计算值）"}],"search_zh":"固体燃料：烟煤 高位发热量 量热法 范围 低位发热量（计算值） PN-ISO 1928:2020-05","technique_zh":"量热法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a7f1934bc25eed9be28d82d","lab_id":"69ad52a3de79e566650fb5b8","country":"PL","accr_number":"AB 1120","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(40,00 – 85,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres (40,00 – 85,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"ISO 29541:2025","norm_bases":["ISO 29541:2025"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość węgla całkowitego\nZakres (40,00 – 85,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR ISO 29541:2025 Paliwa stale: wegiel kamienny Zawartosc wegla calkowitego\nZakres (40,00 – 85,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR ISO 29541:2025","categories":["petro"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(40,00 – 85,00) %"}],"search_en":"Solid fuels: hard coal Total carbon content High-temperature combustion with IR detection Range ISO 29541:2025","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(40,00 – 85,00) %"}],"search_zh":"固体燃料：烟煤 总碳含量 高温燃烧红外检测法 范围 ISO 29541:2025","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a7f1934bc25eed9be28d82e","lab_id":"69ad52a3de79e566650fb5b8","country":"PL","accr_number":"AB 1120","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość azotu","parameters":[{"name":"Zakres","range":"(0,70 – 3,70) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TC","techniques":["Metoda wysokotemperaturowego spalania z detekcją TC"],"computed":[],"activity":"Zawartość azotu\nZakres (0,70 – 3,70) %\nMetoda wysokotemperaturowego spalania z detekcją TC","reference":"ISO 29541:2025","norm_bases":["ISO 29541:2025"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość azotu\nZakres (0,70 – 3,70) %\nMetoda wysokotemperaturowego spalania z detekcją TC ISO 29541:2025 Paliwa stale: wegiel kamienny Zawartosc azotu\nZakres (0,70 – 3,70) %\nMetoda wysokotemperaturowego spalania z detekcja TC ISO 29541:2025","categories":["petro"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen content","parameters_en":[{"name":"Range","range":"(0,70 – 3,70) %"}],"search_en":"Solid fuels: hard coal Nitrogen content High-temperature combustion with TC detection Range ISO 29541:2025","technique_en":"High-temperature combustion with TC detection","test_object_en":"Solid fuels: hard coal","methodology_zh":"氮含量","parameters_zh":[{"name":"范围","range":"(0,70 – 3,70) %"}],"search_zh":"固体燃料：烟煤 氮含量 高温燃烧总碳检测法 范围 ISO 29541:2025","test_object_zh":"固体燃料：烟煤","technique_zh":"高温燃烧总碳检测法"},{"_id":"6a7f1934bc25eed9be28d82f","lab_id":"69ad52a3de79e566650fb5b8","country":"PL","accr_number":"AB 1120","accr_body":"PCA","test_object":"OdpadyO): kod 10 01 01, 10 01 02, 10 01 80","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(0,20 – 45,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres (0,20 – 45,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"OdpadyO): kod 10 01 01, 10 01 02, 10 01 80 Zawartość węgla całkowitego\nZakres (0,20 – 45,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 OdpadyO): kod 10 01 01, 10 01 02, 10 01 80 Zawartosc wegla calkowitego\nZakres (0,20 – 45,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(0,20 – 45,00) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"WasteO): code 10 01 01, 10 01 02, 10 01 80 Total carbon content High-temperature combustion with IR detection waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-G-04571:1998","technique_en":"High-temperature combustion with IR detection","test_object_en":"WasteO): code 10 01 01, 10 01 02, 10 01 80","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(0,20 – 45,00) %"}],"search_zh":"总碳含量 高温燃烧红外检测法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a7f1934bc25eed9be28d830","lab_id":"69ad52a3de79e566650fb5b8","country":"PL","accr_number":"AB 1120","accr_body":"PCA","test_object":"OdpadyO): kod 10 01 01, 10 01 02, 10 01 80","methodology":"Zawartość wilgoci analitycznej","parameters":[{"name":"Zakres","range":"(0,05 – 2,80) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość wilgoci analitycznej\nZakres (0,05 – 2,80) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"OdpadyO): kod 10 01 01, 10 01 02, 10 01 80 Zawartość wilgoci analitycznej\nZakres (0,05 – 2,80) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 OdpadyO): kod 10 01 01, 10 01 02, 10 01 80 Zawartosc wilgoci analitycznej\nZakres (0,05 – 2,80) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Analytical moisture content","parameters_en":[{"name":"Range","range":"(0,05 – 2,80) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"WasteO): code 10 01 01, 10 01 02, 10 01 80 Analytical moisture content Thermogravimetric method (TGA) waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-G-04560:1998","technique_en":"Thermogravimetric method (TGA)","test_object_en":"WasteO): code 10 01 01, 10 01 02, 10 01 80","parameters_zh":[{"name":"范围","range":"(0,05 – 2,80) %"}],"search_zh":"分析水分含量 热重法（TGA） 依据气候部长关于废物目录的条例的废物代码。 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。","methodology_zh":"分析水分含量"},{"_id":"6a7f1934bc25eed9be28d831","lab_id":"69ad52a3de79e566650fb5b8","country":"PL","accr_number":"AB 1120","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe","methodology":"Zawartość wilgoci całkowitej","parameters":[{"name":"Zakres","range":"(5,0 – 65,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci całkowitej\nZakres (5,0 – 65,0) %\nMetoda wagowa","reference":"PN-EN ISO 18134-2:2024-10","norm_bases":["PN-EN ISO 18134-2:2024-10"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe Zawartość wilgoci całkowitej\nZakres (5,0 – 65,0) %\nMetoda wagowa PN-EN ISO 18134-2:2024-10 Paliwa stale: biomasa stala - biopaliwo stale Zawartosc wilgoci calkowitej\nZakres (5,0 – 65,0) %\nMetoda wagowa PN-EN ISO 18134-2:2024-10","categories":["petro"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content","parameters_en":[{"name":"Range","range":"(5,0 – 65,0) %"}],"search_en":"Solid fuels: solid biomass - solid biofuel Total moisture content Gravimetric method Range PN-EN ISO 18134-2:2024-10","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid biomass - solid biofuel","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(5,0 – 65,0) %"}],"search_zh":"固体燃料：固体生物质 — 固体生物燃料 全水分含量 重量法 范围 PN-EN ISO 18134-2:2024-10","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物质 — 固体生物燃料"},{"_id":"6a7f1934bc25eed9be28d832","lab_id":"69ad52a3de79e566650fb5b8","country":"PL","accr_number":"AB 1120","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(3,0 – 10,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (3,0 – 10,0) %\nMetoda wagowa","reference":"PN-EN ISO 18134-3:2023-12","norm_bases":["PN-EN ISO 18134-3:2023-12"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe Zawartość wilgoci w próbce analitycznej\nZakres (3,0 – 10,0) %\nMetoda wagowa PN-EN ISO 18134-3:2023-12 Paliwa stale: biomasa stala - biopaliwo stale Zawartosc wilgoci w probce analitycznej\nZakres (3,0 – 10,0) %\nMetoda wagowa PN-EN ISO 18134-3:2023-12","categories":["petro"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(3,0 – 10,0) %"}],"search_en":"Solid fuels: solid biomass - solid biofuel Moisture content in the analytical sample Gravimetric method Range PN-EN ISO 18134-3:2023-12","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid biomass - solid biofuel","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(3,0 – 10,0) %"}],"search_zh":"固体燃料：固体生物质 — 固体生物燃料 分析样品水分含量 重量法 范围 PN-EN ISO 18134-3:2023-12","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物质 — 固体生物燃料"},{"_id":"6a7f1934bc25eed9be28d833","lab_id":"69ad52a3de79e566650fb5b8","country":"PL","accr_number":"AB 1120","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(0,2 – 30,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu\nZakres (0,2 – 30,0) %\nMetoda wagowa","reference":"PN-EN ISO 18122:2023-05","norm_bases":["PN-EN ISO 18122:2023-05"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe Zawartość popiołu\nZakres (0,2 – 30,0) %\nMetoda wagowa PN-EN ISO 18122:2023-05 Paliwa stale: biomasa stala - biopaliwo stale Zawartosc popiolu\nZakres (0,2 – 30,0) %\nMetoda wagowa PN-EN ISO 18122:2023-05","categories":["petro"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(0,2 – 30,0) %"}],"search_en":"Solid fuels: solid biomass - solid biofuel Ash content Gravimetric method Range PN-EN ISO 18122:2023-05","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid biomass - solid biofuel","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,2 – 30,0) %"}],"search_zh":"固体燃料：固体生物质 — 固体生物燃料 灰分含量 重量法 范围 PN-EN ISO 18122:2023-05","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物质 — 固体生物燃料"},{"_id":"6a7f1934bc25eed9be28d834","lab_id":"69ad52a3de79e566650fb5b8","country":"PL","accr_number":"AB 1120","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(0,4 – 30,0) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość popiołu\nZakres (0,4 – 30,0) %\nMetoda termograwimetryczna (TGA)","reference":"PN-EN ISO 18122:2023-05","norm_bases":["PN-EN ISO 18122:2023-05"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe Zawartość popiołu\nZakres (0,4 – 30,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 18122:2023-05 Paliwa stale: biomasa stala - biopaliwo stale Zawartosc popiolu\nZakres (0,4 – 30,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 18122:2023-05","categories":["petro"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(0,4 – 30,0) %"}],"search_en":"Solid fuels: solid biomass - solid biofuel Ash content Thermogravimetric method (TGA) Range PN-EN ISO 18122:2023-05","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Solid fuels: solid biomass - solid biofuel","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,4 – 30,0) %"}],"search_zh":"固体燃料：固体生物质 — 固体生物燃料 灰分含量 热重法（TGA） 范围 PN-EN ISO 18122:2023-05","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：固体生物质 — 固体生物燃料"},{"_id":"6a7f1934bc25eed9be28d835","lab_id":"69ad52a3de79e566650fb5b8","country":"PL","accr_number":"AB 1120","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(3,0 – 10,0) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (3,0 – 10,0) %\nMetoda termograwimetryczna (TGA)","reference":"PN-EN ISO 18134-3:2023-12","norm_bases":["PN-EN ISO 18134-3:2023-12"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe Zawartość wilgoci w próbce analitycznej\nZakres (3,0 – 10,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 18134-3:2023-12 Paliwa stale: biomasa stala - biopaliwo stale Zawartosc wilgoci w probce analitycznej\nZakres (3,0 – 10,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 18134-3:2023-12","categories":["petro"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(3,0 – 10,0) %"}],"search_en":"Solid fuels: solid biomass - solid biofuel Moisture content in the analytical sample Thermogravimetric method (TGA) Range PN-EN ISO 18134-3:2023-12","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Solid fuels: solid biomass - solid biofuel","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(3,0 – 10,0) %"}],"search_zh":"固体燃料：固体生物质 — 固体生物燃料 分析样品水分含量 热重法（TGA） 范围 PN-EN ISO 18134-3:2023-12","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：固体生物质 — 固体生物燃料"},{"_id":"6a7f1934bc25eed9be28d836","lab_id":"69ad52a3de79e566650fb5b8","country":"PL","accr_number":"AB 1120","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,01 – 0,50) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,01 – 0,50) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 16994:2016-10","norm_bases":["PN-EN ISO 16994:2016-10"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe Zawartość siarki całkowitej\nZakres (0,01 – 0,50) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 16994:2016-10 Paliwa stale: biomasa stala - biopaliwo stale Zawartosc siarki calkowitej\nZakres (0,01 – 0,50) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 16994:2016-10","categories":["petro"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,01 – 0,50) %"}],"search_en":"Solid fuels: solid biomass - solid biofuel Total sulfur content High-temperature combustion with IR detection Range PN-EN ISO 16994:2016-10","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: solid biomass - solid biofuel","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,01 – 0,50) %"}],"search_zh":"固体燃料：固体生物质 — 固体生物燃料 全硫含量 高温燃烧红外检测法 范围 PN-EN ISO 16994:2016-10","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：固体生物质 — 固体生物燃料"},{"_id":"6a7f1934bc25eed9be28d837","lab_id":"69ad52a3de79e566650fb5b8","country":"PL","accr_number":"AB 1120","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(14000 – 25000) J/g"},{"name":"Wartość opałowa (z obliczeń)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres:\nZakres (14000 – 25000) J/g\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-EN ISO 18125:2017-07","norm_bases":["PN-EN ISO 18125:2017-07"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe Ciepło spalania\nZakres:\nZakres (14000 – 25000) J/g\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-EN ISO 18125:2017-07 Paliwa stale: biomasa stala - biopaliwo stale Cieplo spalania\nZakres:\nZakres (14000 – 25000) J/g\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-EN ISO 18125:2017-07","categories":["petro"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(14000 – 25000) J/g"},{"name":"Net calorific value (calculated)"}],"search_en":"Solid fuels: solid biomass - solid biofuel Gross calorific value Calorimetric method Range Net calorific value (calculated) PN-EN ISO 18125:2017-07","technique_en":"Calorimetric method","test_object_en":"Solid fuels: solid biomass - solid biofuel","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(14000 – 25000) J/g"},{"name":"低位发热量（计算值）"}],"search_zh":"固体燃料：固体生物质 — 固体生物燃料 高位发热量 量热法 范围 低位发热量（计算值） PN-EN ISO 18125:2017-07","technique_zh":"量热法","test_object_zh":"固体燃料：固体生物质 — 固体生物燃料"},{"_id":"6a7f1934bc25eed9be28d838","lab_id":"69ad52a3de79e566650fb5b8","country":"PL","accr_number":"AB 1120","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(35,0 – 50,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres (35,0 – 50,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 16948:2015-07","norm_bases":["PN-EN ISO 16948:2015-07"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe Zawartość węgla całkowitego\nZakres (35,0 – 50,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 16948:2015-07 Paliwa stale: biomasa stala - biopaliwo stale Zawartosc wegla calkowitego\nZakres (35,0 – 50,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 16948:2015-07","categories":["petro"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(35,0 – 50,0) %"}],"search_en":"Solid fuels: solid biomass - solid biofuel Total carbon content High-temperature combustion with IR detection Range PN-EN ISO 16948:2015-07","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: solid biomass - solid biofuel","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(35,0 – 50,0) %"}],"search_zh":"固体燃料：固体生物质 — 固体生物燃料 总碳含量 高温燃烧红外检测法 范围 PN-EN ISO 16948:2015-07","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：固体生物质 — 固体生物燃料"},{"_id":"6a7f1934bc25eed9be28d839","lab_id":"69ad52a3de79e566650fb5b8","country":"PL","accr_number":"AB 1120","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe","methodology":"Zawartość wodoru","parameters":[{"name":"Zakres","range":"(5,00 – 7,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość wodoru\nZakres (5,00 – 7,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 16948:2015-07","norm_bases":["PN-EN ISO 16948:2015-07"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe Zawartość wodoru\nZakres (5,00 – 7,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 16948:2015-07 Paliwa stale: biomasa stala - biopaliwo stale Zawartosc wodoru\nZakres (5,00 – 7,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 16948:2015-07","categories":["petro"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen content","parameters_en":[{"name":"Range","range":"(5,00 – 7,00) %"}],"search_en":"Solid fuels: solid biomass - solid biofuel Hydrogen content High-temperature combustion with IR detection Range PN-EN ISO 16948:2015-07","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: solid biomass - solid biofuel","parameters_zh":[{"name":"范围","range":"(5,00 – 7,00) %"}],"search_zh":"固体燃料：固体生物质 — 固体生物燃料 氢含量 高温燃烧红外检测法 范围 PN-EN ISO 16948:2015-07","technique_zh":"高温燃烧红外检测法","methodology_zh":"氢含量","test_object_zh":"固体燃料：固体生物质 — 固体生物燃料"},{"_id":"6a7f1934bc25eed9be28d83a","lab_id":"69ad52a3de79e566650fb5b8","country":"PL","accr_number":"AB 1120","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe","methodology":"Zawartość azotu","parameters":[{"name":"Zakres","range":"(0,15 – 2,50) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TC","techniques":["Metoda wysokotemperaturowego spalania z detekcją TC"],"computed":[],"activity":"Zawartość azotu\nZakres (0,15 – 2,50) %\nMetoda wysokotemperaturowego spalania z detekcją TC","reference":"PN-EN ISO 16948:2015-07","norm_bases":["PN-EN ISO 16948:2015-07"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe Zawartość azotu\nZakres (0,15 – 2,50) %\nMetoda wysokotemperaturowego spalania z detekcją TC PN-EN ISO 16948:2015-07 Paliwa stale: biomasa stala - biopaliwo stale Zawartosc azotu\nZakres (0,15 – 2,50) %\nMetoda wysokotemperaturowego spalania z detekcja TC PN-EN ISO 16948:2015-07","categories":["petro"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen content","parameters_en":[{"name":"Range","range":"(0,15 – 2,50) %"}],"search_en":"Solid fuels: solid biomass - solid biofuel Nitrogen content High-temperature combustion with TC detection Range PN-EN ISO 16948:2015-07","technique_en":"High-temperature combustion with TC detection","test_object_en":"Solid fuels: solid biomass - solid biofuel","methodology_zh":"氮含量","parameters_zh":[{"name":"范围","range":"(0,15 – 2,50) %"}],"search_zh":"固体燃料：固体生物质 — 固体生物燃料 氮含量 高温燃烧总碳检测法 范围 PN-EN ISO 16948:2015-07","test_object_zh":"固体燃料：固体生物质 — 固体生物燃料","technique_zh":"高温燃烧总碳检测法"},{"_id":"6a7f1934bc25eed9be28d83b","lab_id":"69ad52a3de79e566650fb5b8","country":"PL","accr_number":"AB 1120","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy lekki","methodology":"Gęstość w temp. 15°C","parameters":[{"name":"Zakres","range":"(815,0 – 850,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temp. 15°C\nZakres (815,0 – 850,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy lekki Gęstość w temp. 15°C\nZakres (815,0 – 850,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: olej opalowy lekki Gestosc w temp. 15°C\nZakres (815,0 – 850,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density at 15°C","parameters_en":[{"name":"Range","range":"(815,0 – 850,0) kg/m3"}],"search_en":"Liquid fuels: light fuel oil Density at 15°C Oscillation method Range PN-EN ISO 12185:2024-08","technique_en":"Oscillation method","test_object_en":"Liquid fuels: light fuel oil","parameters_zh":[{"name":"范围","range":"(815,0 – 850,0) kg/m3"}],"search_zh":"液体燃料：轻质燃料油 振荡法 范围 PN-EN ISO 12185:2024-08","technique_zh":"振荡法","test_object_zh":"液体燃料：轻质燃料油"},{"_id":"6a7f1934bc25eed9be28d83c","lab_id":"69ad52a3de79e566650fb5b8","country":"PL","accr_number":"AB 1120","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy lekki","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(0,002 – 0,100) %(m/m)"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii"],"computed":[],"activity":"Zawartość siarki\nZakres (0,002 – 0,100) %(m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii","reference":"PN-EN ISO 8754:2007","norm_bases":["PN-EN ISO 8754:2007"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy lekki Zawartość siarki\nZakres (0,002 – 0,100) %(m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii PN-EN ISO 8754:2007 Paliwa ciekle: olej opalowy lekki Zawartosc siarki\nZakres (0,002 – 0,100) %(m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja energii PN-EN ISO 8754:2007","categories":["petro"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(0,002 – 0,100) %(m/m)"}],"search_en":"Liquid fuels: light fuel oil Sulfur content Energy-dispersive X-ray fluorescence spectrometry Range PN-EN ISO 8754:2007","technique_en":"Energy-dispersive X-ray fluorescence spectrometry","test_object_en":"Liquid fuels: light fuel oil","parameters_zh":[{"name":"范围","range":"(0,002 – 0,100) %(m/m)"}],"search_zh":"液体燃料：轻质燃料油 硫含量 能量色散X射线荧光光谱法 范围 PN-EN ISO 8754:2007","methodology_zh":"硫含量","technique_zh":"能量色散X射线荧光光谱法","test_object_zh":"液体燃料：轻质燃料油"},{"_id":"6a7f1934bc25eed9be28d83d","lab_id":"69ad52a3de79e566650fb5b8","country":"PL","accr_number":"AB 1120","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy lekki","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(45300 – 46200) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres:\nZakres (45300 – 46200) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-C-04062:2018-05","norm_bases":["PN-C-04062:2018-05"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy lekki Ciepło spalania\nZakres:\nZakres (45300 – 46200) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-C-04062:2018-05 Paliwa ciekle: olej opalowy lekki Cieplo spalania\nZakres:\nZakres (45300 – 46200) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-C-04062:2018-05","categories":["petro"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(45300 – 46200) kJ/kg"},{"name":"Net calorific value (calculated)"}],"search_en":"Liquid fuels: light fuel oil Gross calorific value Calorimetric method Range Net calorific value (calculated) PN-C-04062:2018-05","technique_en":"Calorimetric method","test_object_en":"Liquid fuels: light fuel oil","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(45300 – 46200) kJ/kg"},{"name":"低位发热量（计算值）"}],"search_zh":"液体燃料：轻质燃料油 高位发热量 量热法 范围 低位发热量（计算值） PN-C-04062:2018-05","technique_zh":"量热法","test_object_zh":"液体燃料：轻质燃料油"}],"has_pdf":true}