{"lab":{"_id":"69ad52a3de79e566650fb5a8","accr_number":"AB 1110","country":"PL","accr_body":"PCA","address":"ul. Łączna 30, 41-303 Dąbrowa Górnicza","categories":["construction"],"city":"Dąbrowa Górnicza","imported_at":"2026-03-08T10:42:43.265Z","methods_count":55,"name":"Laboratorium Inżynierii Lądowej Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1110.pdf"],"scope_summary":"","search_text":"laboratorium inżynierii lądowej sp. z o.o. ul. łączna 30, 41-303 dąbrowa górnicza other materials pharma construction water","status":"active","updated_at":"2026-03-08T14:50:17.467Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T07:57:19.008Z","parse_date":"2026-08-13T07:57:19.008Z","parse_source":"agent-claude-code","email_confidence":"low","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%201110,podmiot.html","needs_review":true,"review_reason":"e-mail niepewny (low) — zweryfikuj","fields_of_testing":[{"codes":"N/5","pl":"Badania właściwości fizycznych wyrobów budowlanych, materiałów budowlanych, obiektów budowlanych","en":"Tests of physical properties of building products, building materials, building items"},{"codes":"J/5","pl":"Badania mechaniczne wyrobów budowlanych, obiektów budowlanych","en":"Mechanical tests of building products, building items"},{"codes":"N/5/P","pl":"Badania właściwości fizycznych i pobieranie próbek materiałów budowlanych, wyrobów budowlanych, obiektów budowlanych","en":"Tests of physical properties and sampling of building materials, building products, building items"},{"codes":"J/5/P","pl":"Badania mechaniczne i pobieranie próbek wyrobów budowlanych, obiektów budowlanych","en":"Mechanical tests and sampling of building products, buidling items"},{"codes":"N/31","pl":"Badania właściwości fizycznych gruntów","en":"Tests of physical properties of ground"},{"codes":"J/31","pl":"Badania mechaniczne gruntów","en":"Mechanical tests of ground"},{"codes":"N/31/P","pl":"Badania właściwości fizycznych i pobieranie próbek gruntów","en":"Tests of physical properties and sampling of ground"},{"codes":"J/31/P","pl":"Badania mechaniczne i pobieranie próbek gruntów","en":"Mechanical tests and sampling of ground"},{"codes":"N/45","pl":"Badanie właściwości fizycznych farb","en":"Tests of physical properties of paints"}],"issue":{"no":"26","date":"01.07.2026"},"map_coord":[50.342034,19.240828],"map_geo":"nominatim-street","lab_locations":[{"name":"Laboratorium Inżynierii Lądowej Sp. z o.o.","address":"ul. Łączna 30","city":null,"postal":null},{"name":"Laboratorium Inżynierii Lądowej","address":"ul. Łączna 30, 41-303 Dąbrowa Górnicza","city":"Dąbrowa Górnicza","postal":"41-303"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/2c89c1d79fba8189e9c4b5daf50f973b/AB%201110.pdf","has_en":true,"category_counts":{"other":42,"construction":13,"water":2},"category_scores":{"other":30.95,"construction":2.96,"water":0.07},"has_zh":true,"lab_locations_zh":[{"name":"Laboratorium Inżynierii Lądowej Sp. z o.o.","address":"ul. Łączna 30","city":null,"postal":null},{"name":"土木工程实验室","address":"ul. Łączna 30, 41-303 Dąbrowa Górnicza","city":"Dąbrowa Górnicza","postal":"41-303"}]},"methods":[{"_id":"6a7d78df0636ba417e41a379","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Grunty","methodology":"Uziarnienie","parameters":[{"name":"Zakres","range":"(0,0 - 40) mm"}],"technique":"Metoda analizy sitowej","techniques":["Metoda analizy sitowej"],"computed":[],"activity":"Uziarnienie\nZakres (0,0 - 40) mm\nMetoda analizy sitowej","reference":"PN-B-04481:1988","norm_bases":["PN-B-04481:1988"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Uziarnienie\nZakres (0,0 - 40) mm\nMetoda analizy sitowej PN-B-04481:1988 Grunty Uziarnienie\nZakres (0,0 - 40) mm\nMetoda analizy sitowej PN-B-04481:1988","categories":["other"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Grading","parameters_en":[{"name":"Range","range":"(0,0 - 40) mm"}],"search_en":"Ground Grading Sieve analysis method Civil Engineering Laboratory Range PN-B-04481:1988","technique_en":"Sieve analysis method","test_object_en":"Ground","parameters_zh":[{"name":"范围","range":"(0,0 - 40) mm"}],"search_zh":"土体 级配 筛分分析法 土木工程实验室 范围 PN-B-04481:1988","test_object_zh":"土体","lab_section_zh":"土木工程实验室","methodology_zh":"级配","technique_zh":"筛分分析法"},{"_id":"6a7d78df0636ba417e41a37a","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Grunty","methodology":"Wilgotność","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Wilgotność\nMetoda wagowa","reference":"PN-B-04481:1988 | PN-EN-1097-5:2008","norm_bases":["PN-B-04481:1988","PN-EN-1097-5:2008"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Wilgotność\nMetoda wagowa PN-B-04481:1988 | PN-EN-1097-5:2008 Grunty Wilgotnosc\nMetoda wagowa PN-B-04481:1988 | PN-EN-1097-5:2008","categories":["other"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Humidity","search_en":"Ground Humidity Gravimetric method Civil Engineering Laboratory PN-B-04481:1988 | PN-EN-1097-5:2008","technique_en":"Gravimetric method","test_object_en":"Ground","search_zh":"土体 湿度 重量法 土木工程实验室 PN-B-04481:1988 | PN-EN-1097-5:2008","technique_zh":"重量法","test_object_zh":"土体","lab_section_zh":"土木工程实验室","methodology_zh":"湿度"},{"_id":"6a7d78df0636ba417e41a37b","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Grunty","methodology":"Wilgotność optymalna, Maksymalna gęstość szkieletu gruntowego","parameters":[],"technique":"Metoda Proctora","techniques":["Metoda Proctora"],"computed":[],"activity":"Wilgotność optymalna, Maksymalna gęstość szkieletu gruntowego\nMetoda Proctora","reference":"PN-B-04481:1988","norm_bases":["PN-B-04481:1988"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Wilgotność optymalna, Maksymalna gęstość szkieletu gruntowego\nMetoda Proctora PN-B-04481:1988 Grunty Wilgotnosc optymalna, Maksymalna gestosc szkieletu gruntowego\nMetoda Proctora PN-B-04481:1988","categories":["other"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Optimum moisture content, Maximum dry density of the soil skeleton","search_en":"Ground Optimum moisture content, Maximum dry density of the soil skeleton Proctor method Civil Engineering Laboratory PN-B-04481:1988","technique_en":"Proctor method","test_object_en":"Ground","search_zh":"土体 普氏击实法 土木工程实验室 PN-B-04481:1988","test_object_zh":"土体","lab_section_zh":"土木工程实验室","technique_zh":"普氏击实法"},{"_id":"6a7d78df0636ba417e41a37c","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Grunty","methodology":"Wskaźnik nośności gruntu (wnoś)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik nośności gruntu (wnoś)","reference":"PN-S-02205:1998 zał. A | PN-B-04481:1988","norm_bases":["PN-S-02205:1998 zał. A","PN-B-04481:1988"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Wskaźnik nośności gruntu (wnoś) PN-S-02205:1998 zał. A | PN-B-04481:1988 Grunty Wskaznik nosnosci gruntu (wnos) PN-S-02205:1998 zal. A | PN-B-04481:1988","categories":["other"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Soil bearing ratio (wnoś)","search_en":"Ground Soil bearing ratio (wnoś) Civil Engineering Laboratory PN-S-02205:1998 zał. A | PN-B-04481:1988","test_object_en":"Ground","search_zh":"土体 土木工程实验室 PN-S-02205:1998 zał. A | PN-B-04481:1988","test_object_zh":"土体","lab_section_zh":"土木工程实验室"},{"_id":"6a7d78df0636ba417e41a37d","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Grunty","methodology":"Wskaźnik zagęszczenia","parameters":[],"technique":"Metoda: cylindra wciskanego","techniques":["Metoda: cylindra wciskanego"],"computed":[],"activity":"Wskaźnik zagęszczenia\nMetoda: cylindra wciskanego","reference":"BN-77/8931-12 | PN-B-04481:1988","norm_bases":["BN-77/8931-12","PN-B-04481:1988"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Wskaźnik zagęszczenia\nMetoda: cylindra wciskanego BN-77/8931-12 | PN-B-04481:1988 Grunty Wskaznik zageszczenia\nMetoda: cylindra wciskanego BN-77/8931-12 | PN-B-04481:1988","categories":["other"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Compaction index","search_en":"Ground Compaction index Method: pressed-in cylinder Civil Engineering Laboratory BN-77/8931-12 | PN-B-04481:1988","technique_en":"Method: pressed-in cylinder","test_object_en":"Ground","search_zh":"土体 土木工程实验室 BN-77/8931-12 | PN-B-04481:1988","test_object_zh":"土体","lab_section_zh":"土木工程实验室"},{"_id":"6a7d78df0636ba417e41a37e","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Grunty","methodology":"Wskaźnik piaskowy","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik piaskowy","reference":"PN-EN 933-8+A1:2015","norm_bases":["PN-EN 933-8+A1:2015"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Wskaźnik piaskowy PN-EN 933-8+A1:2015 Grunty Wskaznik piaskowy PN-EN 933-8+A1:2015","categories":["other"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Sand equivalent value","search_en":"Ground Sand equivalent value Civil Engineering Laboratory PN-EN 933-8+A1:2015","test_object_en":"Ground","search_zh":"土体 砂当量 土木工程实验室 PN-EN 933-8+A1:2015","test_object_zh":"土体","lab_section_zh":"土木工程实验室","methodology_zh":"砂当量"},{"_id":"6a7d78df0636ba417e41a37f","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Grunty","methodology":"Zawartość części organicznych","parameters":[],"technique":"Metoda: utleniania","techniques":["Metoda: utleniania"],"computed":[],"activity":"Zawartość części organicznych\nMetoda: utleniania","reference":"PN-B-04481:1988","norm_bases":["PN-B-04481:1988"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Zawartość części organicznych\nMetoda: utleniania PN-B-04481:1988 Grunty Zawartosc czesci organicznych\nMetoda: utleniania PN-B-04481:1988","categories":["other"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Organic matter content","search_en":"Ground Organic matter content Method: oxidation Civil Engineering Laboratory PN-B-04481:1988","technique_en":"Method: oxidation","test_object_en":"Ground","search_zh":"土体 有机组分含量 土木工程实验室 PN-B-04481:1988","test_object_zh":"土体","lab_section_zh":"土木工程实验室","methodology_zh":"有机组分含量"},{"_id":"6a7d78df0636ba417e41a380","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Grunty","methodology":"Kapilarność bierna","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Kapilarność bierna","reference":"PN-B-04493:1960 | PN-B-04481:1988","norm_bases":["PN-B-04493:1960","PN-B-04481:1988"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Kapilarność bierna PN-B-04493:1960 | PN-B-04481:1988 Grunty Kapilarnosc bierna PN-B-04493:1960 | PN-B-04481:1988","categories":["other"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Passive capillarity","search_en":"Ground Passive capillarity Civil Engineering Laboratory PN-B-04493:1960 | PN-B-04481:1988","test_object_en":"Ground","search_zh":"土体 被动毛细吸水性 土木工程实验室 PN-B-04493:1960 | PN-B-04481:1988","test_object_zh":"土体","lab_section_zh":"土木工程实验室","methodology_zh":"被动毛细吸水性"},{"_id":"6a7d78df0636ba417e41a381","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Grunty","methodology":"Moduł odkształcenia","parameters":[{"name":"Zakres ciśnienia (0,02 – 0,35) MPa"},{"name":"Wskaźnik odkształcenia (z obliczeń)"}],"technique":"Metoda obciążeń płytą VSS","techniques":["Metoda obciążeń płytą VSS"],"computed":[],"activity":"Moduł odkształcenia\nZakres:\nZakres ciśnienia (0,02 – 0,35) MPa\nWskaźnik odkształcenia (z obliczeń)\nMetoda obciążeń płytą VSS","reference":"PN-S-02205:1998","norm_bases":["PN-S-02205:1998"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Moduł odkształcenia\nZakres:\nZakres ciśnienia (0,02 – 0,35) MPa\nWskaźnik odkształcenia (z obliczeń)\nMetoda obciążeń płytą VSS PN-S-02205:1998 Grunty Modul odksztalcenia\nZakres:\nZakres cisnienia (0,02 – 0,35) MPa\nWskaznik odksztalcenia (z obliczen)\nMetoda obciazen plyta VSS PN-S-02205:1998","categories":["other"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Deformation modulus","parameters_en":[{"name":"Pressure range (0,02 – 0,35) MPa"},{"name":"Deformation index (calculated)"}],"search_en":"Ground Deformation modulus VSS plate loading method Civil Engineering Laboratory Pressure range (0,02 – 0,35) MPa Deformation index (calculated) PN-S-02205:1998","technique_en":"VSS plate loading method","test_object_en":"Ground","search_zh":"土体 变形模量 VSS 平板荷载法 土木工程实验室 PN-S-02205:1998","test_object_zh":"土体","lab_section_zh":"土木工程实验室","methodology_zh":"变形模量","technique_zh":"VSS 平板荷载法"},{"_id":"6a7d78df0636ba417e41a382","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Grunty","methodology":"Dynamiczny moduł odkształcenia","parameters":[{"name":"Zakres","range":"Evd ≤125MN/m2"},{"name":"LWDT"}],"technique":"Metoda: obciążenia płytą dynamiczną","techniques":["Metoda: obciążenia płytą dynamiczną"],"computed":[],"activity":"Dynamiczny moduł odkształcenia\nZakres:\nZakres Evd ≤125MN/m2\nLWDT\nMetoda: obciążenia płytą dynamiczną","reference":"PBG 10, wersja 03, 26.03.2024","norm_bases":["PBG 10, wersja 03, 26.03.2024"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Dynamiczny moduł odkształcenia\nZakres:\nZakres Evd ≤125MN/m2\nLWDT\nMetoda: obciążenia płytą dynamiczną PBG 10, wersja 03, 26.03.2024 Grunty Dynamiczny modul odksztalcenia\nZakres:\nZakres Evd ≤125MN/m2\nLWDT\nMetoda: obciazenia plyta dynamiczna PBG 10, wersja 03, 26.03.2024","categories":["other"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Dynamic deformation modulus","parameters_en":[{"name":"Range","range":"Evd ≤125MN/m2"},{"name":"LWDT"}],"search_en":"Ground Dynamic deformation modulus Method: dynamic plate loading Civil Engineering Laboratory Range LWDT PBG 10, wersja 03, 26.03.2024","technique_en":"Method: dynamic plate loading","test_object_en":"Ground","parameters_zh":[{"name":"范围","range":"Evd ≤125MN/m2"},{"name":"轻型动力触探（LWDT）"}],"search_zh":"土体 动态变形模量 土木工程实验室 范围 轻型动力触探（LWDT） PBG 10, wersja 03, 26.03.2024","test_object_zh":"土体","lab_section_zh":"土木工程实验室","methodology_zh":"动态变形模量"},{"_id":"6a7d78df0636ba417e41a383","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Grunty","methodology":"Stopień zagęszczenia","parameters":[],"technique":"Metoda: sonda lekka","techniques":["Metoda: sonda lekka"],"computed":[],"activity":"Stopień zagęszczenia\nMetoda: sonda lekka","reference":"PN-B-04452:2002 p.6","norm_bases":["PN-B-04452:2002 p.6"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Stopień zagęszczenia\nMetoda: sonda lekka PN-B-04452:2002 p.6 Grunty Stopien zageszczenia\nMetoda: sonda lekka PN-B-04452:2002 p.6","categories":["other"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Degree of compaction","search_en":"Ground Degree of compaction Method: light probe Civil Engineering Laboratory PN-B-04452:2002 p.6","technique_en":"Method: light probe","test_object_en":"Ground","search_zh":"土体 密实度 方法：轻型触探仪 土木工程实验室 PN-B-04452:2002 p.6","test_object_zh":"土体","lab_section_zh":"土木工程实验室","methodology_zh":"密实度","technique_zh":"方法：轻型触探仪"},{"_id":"6a7d78df0636ba417e41a384","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Grunty","methodology":"Wytrzymałość na ściskanie stabilizacji","parameters":[{"name":"Zakres","range":"(2 - 50) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie stabilizacji\nZakres (2 - 50) kN","reference":"PBG 15, wersja 03, 09.01.2023 | PN-EN 13286-41:2022-04","norm_bases":["PBG 15, wersja 03, 09.01.2023","PN-EN 13286-41:2022-04"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Wytrzymałość na ściskanie stabilizacji\nZakres (2 - 50) kN PBG 15, wersja 03, 09.01.2023 | PN-EN 13286-41:2022-04 Grunty Wytrzymalosc na sciskanie stabilizacji\nZakres (2 - 50) kN PBG 15, wersja 03, 09.01.2023 | PN-EN 13286-41:2022-04","categories":["other"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Compressive strength of the stabilised mixture","parameters_en":[{"name":"Range","range":"(2 - 50) kN"}],"search_en":"Ground Compressive strength of the stabilised mixture Civil Engineering Laboratory Range PBG 15, wersja 03, 09.01.2023 | PN-EN 13286-41:2022-04","test_object_en":"Ground","parameters_zh":[{"name":"范围","range":"(2 - 50) kN"}],"search_zh":"土体 稳定土抗压强度 土木工程实验室 范围 PBG 15, wersja 03, 09.01.2023 | PN-EN 13286-41:2022-04","test_object_zh":"土体","lab_section_zh":"土木工程实验室","methodology_zh":"稳定土抗压强度"},{"_id":"6a7d78df0636ba417e41a385","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Grunty","methodology":"Pobieranie próbek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek","reference":"PN-EN 932-1:1999 p. 8.8.","norm_bases":["PN-EN 932-1:1999 p. 8.8."],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Pobieranie próbek PN-EN 932-1:1999 p. 8.8. Grunty Pobieranie probek PN-EN 932-1:1999 p. 8.8.","categories":["other"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Sampling","search_en":"Ground Sampling Civil Engineering Laboratory PN-EN 932-1:1999 p. 8.8.","test_object_en":"Ground","methodology_zh":"样品采集","search_zh":"土体 样品采集 土木工程实验室 PN-EN 932-1:1999 p. 8.8.","test_object_zh":"土体","lab_section_zh":"土木工程实验室"},{"_id":"6a7d78df0636ba417e41a386","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Kruszywa","methodology":"Skład ziarnowy","parameters":[{"name":"Zakres","range":"(0,0 - 63) mm"}],"technique":"Metoda przesiewania","techniques":["Metoda przesiewania"],"computed":[],"activity":"Skład ziarnowy\nZakres (0,0 - 63) mm\nMetoda przesiewania","reference":"PN-EN 933-1:2012","norm_bases":["PN-EN 933-1:2012"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Skład ziarnowy\nZakres (0,0 - 63) mm\nMetoda przesiewania PN-EN 933-1:2012 Kruszywa Sklad ziarnowy\nZakres (0,0 - 63) mm\nMetoda przesiewania PN-EN 933-1:2012","categories":["other"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Particle size distribution","parameters_en":[{"name":"Range","range":"(0,0 - 63) mm"}],"search_en":"Aggregates Particle size distribution Sieving method Civil Engineering Laboratory Range PN-EN 933-1:2012","technique_en":"Sieving method","test_object_en":"Aggregates","parameters_zh":[{"name":"范围","range":"(0,0 - 63) mm"}],"search_zh":"骨料 粒度分布 筛分法 土木工程实验室 范围 PN-EN 933-1:2012","test_object_zh":"骨料","lab_section_zh":"土木工程实验室","methodology_zh":"粒度分布","technique_zh":"筛分法"},{"_id":"6a7d78df0636ba417e41a387","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Kruszywa","methodology":"Wilgotność","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Wilgotność\nMetoda wagowa","reference":"PN-EN-1097-5:2008","norm_bases":["PN-EN-1097-5:2008"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Wilgotność\nMetoda wagowa PN-EN-1097-5:2008 Kruszywa Wilgotnosc\nMetoda wagowa PN-EN-1097-5:2008","categories":["other"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Humidity","search_en":"Aggregates Humidity Gravimetric method Civil Engineering Laboratory PN-EN-1097-5:2008","technique_en":"Gravimetric method","test_object_en":"Aggregates","search_zh":"骨料 湿度 重量法 土木工程实验室 PN-EN-1097-5:2008","technique_zh":"重量法","test_object_zh":"骨料","lab_section_zh":"土木工程实验室","methodology_zh":"湿度"},{"_id":"6a7d78df0636ba417e41a388","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Kruszywa","methodology":"Wilgotność optymalna, Maksymalna gęstość szkieletu mieszanki kruszywa","parameters":[],"technique":"Metoda Proctora","techniques":["Metoda Proctora"],"computed":[],"activity":"Wilgotność optymalna, Maksymalna gęstość szkieletu mieszanki kruszywa\nMetoda Proctora","reference":"PN-EN 13286-2:2010+AC:2014","norm_bases":["PN-EN 13286-2:2010+AC:2014"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Wilgotność optymalna, Maksymalna gęstość szkieletu mieszanki kruszywa\nMetoda Proctora PN-EN 13286-2:2010+AC:2014 Kruszywa Wilgotnosc optymalna, Maksymalna gestosc szkieletu mieszanki kruszywa\nMetoda Proctora PN-EN 13286-2:2010+AC:2014","categories":["other"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Optimum moisture content, Maximum dry density of the aggregate mixture skeleton","search_en":"Aggregates Optimum moisture content, Maximum dry density of the aggregate mixture skeleton Proctor method Civil Engineering Laboratory PN-EN 13286-2:2010+AC:2014","technique_en":"Proctor method","test_object_en":"Aggregates","search_zh":"骨料 普氏击实法 土木工程实验室 PN-EN 13286-2:2010+AC:2014","test_object_zh":"骨料","lab_section_zh":"土木工程实验室","technique_zh":"普氏击实法"},{"_id":"6a7d78df0636ba417e41a389","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Kruszywa","methodology":"Kalifornijski wskaźnik nośności (CBR)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Kalifornijski wskaźnik nośności (CBR)","reference":"PN-EN 13286-47:2022-04","norm_bases":["PN-EN 13286-47:2022-04"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Kalifornijski wskaźnik nośności (CBR) PN-EN 13286-47:2022-04 Kruszywa Kalifornijski wskaznik nosnosci (CBR) PN-EN 13286-47:2022-04","categories":["other"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"California bearing ratio (CBR)","search_en":"Aggregates California bearing ratio (CBR) Civil Engineering Laboratory PN-EN 13286-47:2022-04","test_object_en":"Aggregates","search_zh":"骨料 加州承载比（CBR） 土木工程实验室 PN-EN 13286-47:2022-04","test_object_zh":"骨料","lab_section_zh":"土木工程实验室","methodology_zh":"加州承载比（CBR）"},{"_id":"6a7d78df0636ba417e41a38a","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Kruszywa","methodology":"Wskaźnik piaskowy","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik piaskowy","reference":"PN-EN 933-8+A1:2015","norm_bases":["PN-EN 933-8+A1:2015"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Wskaźnik piaskowy PN-EN 933-8+A1:2015 Kruszywa Wskaznik piaskowy PN-EN 933-8+A1:2015","categories":["other"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Sand equivalent value","search_en":"Aggregates Sand equivalent value Civil Engineering Laboratory PN-EN 933-8+A1:2015","test_object_en":"Aggregates","search_zh":"骨料 砂当量 土木工程实验室 PN-EN 933-8+A1:2015","test_object_zh":"骨料","lab_section_zh":"土木工程实验室","methodology_zh":"砂当量"},{"_id":"6a7d78df0636ba417e41a38b","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Kruszywa","methodology":"Zawartość części organicznych","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Zawartość części organicznych\nMetoda wizualna","reference":"PN-EN 1744-1+A1:2013-05","norm_bases":["PN-EN 1744-1+A1:2013-05"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Zawartość części organicznych\nMetoda wizualna PN-EN 1744-1+A1:2013-05 Kruszywa Zawartosc czesci organicznych\nMetoda wizualna PN-EN 1744-1+A1:2013-05","categories":["other"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Organic matter content","search_en":"Aggregates Organic matter content Visual method Civil Engineering Laboratory PN-EN 1744-1+A1:2013-05","technique_en":"Visual method","test_object_en":"Aggregates","search_zh":"骨料 有机组分含量 目视法 土木工程实验室 PN-EN 1744-1+A1:2013-05","technique_zh":"目视法","test_object_zh":"骨料","lab_section_zh":"土木工程实验室","methodology_zh":"有机组分含量"},{"_id":"6a7d78df0636ba417e41a38c","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Kruszywa","methodology":"Kapilarność bierna","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Kapilarność bierna","reference":"PN-B-04493:1960","norm_bases":["PN-B-04493:1960"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Kapilarność bierna PN-B-04493:1960 Kruszywa Kapilarnosc bierna PN-B-04493:1960","categories":["other"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Passive capillarity","search_en":"Aggregates Passive capillarity Civil Engineering Laboratory PN-B-04493:1960","test_object_en":"Aggregates","search_zh":"骨料 被动毛细吸水性 土木工程实验室 PN-B-04493:1960","test_object_zh":"骨料","lab_section_zh":"土木工程实验室","methodology_zh":"被动毛细吸水性"},{"_id":"6a7d78df0636ba417e41a38d","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Kruszywa","methodology":"Stopień zagęszczenia","parameters":[],"technique":"Metoda: sonda lekka","techniques":["Metoda: sonda lekka"],"computed":[],"activity":"Stopień zagęszczenia\nMetoda: sonda lekka","reference":"PN-B-04452:2002 p.6","norm_bases":["PN-B-04452:2002 p.6"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Stopień zagęszczenia\nMetoda: sonda lekka PN-B-04452:2002 p.6 Kruszywa Stopien zageszczenia\nMetoda: sonda lekka PN-B-04452:2002 p.6","categories":["other"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Degree of compaction","search_en":"Aggregates Degree of compaction Method: light probe Civil Engineering Laboratory PN-B-04452:2002 p.6","technique_en":"Method: light probe","test_object_en":"Aggregates","search_zh":"骨料 密实度 方法：轻型触探仪 土木工程实验室 PN-B-04452:2002 p.6","test_object_zh":"骨料","lab_section_zh":"土木工程实验室","methodology_zh":"密实度","technique_zh":"方法：轻型触探仪"},{"_id":"6a7d78df0636ba417e41a38e","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Kruszywa","methodology":"Mrozoodporność","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Mrozoodporność","reference":"PN-EN 1367-1:2007","norm_bases":["PN-EN 1367-1:2007"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Mrozoodporność PN-EN 1367-1:2007 Kruszywa Mrozoodpornosc PN-EN 1367-1:2007","categories":["other"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Frost resistance","search_en":"Aggregates Frost resistance Civil Engineering Laboratory PN-EN 1367-1:2007","test_object_en":"Aggregates","search_zh":"骨料 抗冻性 土木工程实验室 PN-EN 1367-1:2007","test_object_zh":"骨料","lab_section_zh":"土木工程实验室","methodology_zh":"抗冻性"},{"_id":"6a7d78df0636ba417e41a38f","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Kruszywa","methodology":"Nasiąkliwość","parameters":[],"technique":"Metoda: wagowa","techniques":["Metoda: wagowa"],"computed":[],"activity":"Nasiąkliwość\nMetoda: wagowa","reference":"PN-EN 1097-6:2013 | PN-EN 1097-6:2022-07","norm_bases":["PN-EN 1097-6:2013","PN-EN 1097-6:2022-07"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Nasiąkliwość\nMetoda: wagowa PN-EN 1097-6:2013 | PN-EN 1097-6:2022-07 Kruszywa Nasiakliwosc\nMetoda: wagowa PN-EN 1097-6:2013 | PN-EN 1097-6:2022-07","categories":["other"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Water absorption","search_en":"Aggregates Water absorption Method: gravimetric Civil Engineering Laboratory PN-EN 1097-6:2013 | PN-EN 1097-6:2022-07","technique_en":"Method: gravimetric","test_object_en":"Aggregates","methodology_zh":"吸水率","search_zh":"骨料 吸水率 方法：重量法 土木工程实验室 PN-EN 1097-6:2013 | PN-EN 1097-6:2022-07","test_object_zh":"骨料","lab_section_zh":"土木工程实验室","technique_zh":"方法：重量法"},{"_id":"6a7d78df0636ba417e41a390","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Kruszywa","methodology":"Gęstość","parameters":[],"technique":"Metoda: -piknometryczna -drucianego kosza","techniques":["Metoda: -piknometryczna -drucianego kosza"],"computed":[],"activity":"Gęstość\nMetoda: -piknometryczna -drucianego kosza","reference":"PN-EN 1097-6:2013 | PN-EN 1097-6:2022-07","norm_bases":["PN-EN 1097-6:2013","PN-EN 1097-6:2022-07"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Gęstość\nMetoda: -piknometryczna -drucianego kosza PN-EN 1097-6:2013 | PN-EN 1097-6:2022-07 Kruszywa Gestosc\nMetoda: -piknometryczna -drucianego kosza PN-EN 1097-6:2013 | PN-EN 1097-6:2022-07","categories":["other"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Density","search_en":"Aggregates Density Method: -pycnometric -wire basket Civil Engineering Laboratory PN-EN 1097-6:2013 | PN-EN 1097-6:2022-07","technique_en":"Method: -pycnometric -wire basket","test_object_en":"Aggregates","methodology_zh":"密度","search_zh":"骨料 密度 土木工程实验室 PN-EN 1097-6:2013 | PN-EN 1097-6:2022-07","test_object_zh":"骨料","lab_section_zh":"土木工程实验室"},{"_id":"6a7d78df0636ba417e41a391","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Kruszywa","methodology":"Odporność na rozdrabnianie","parameters":[],"technique":"Metoda: Los Angeles","techniques":["Metoda: Los Angeles"],"computed":[],"activity":"Odporność na rozdrabnianie\nMetoda: Los Angeles","reference":"PN-EN 1097-2:2010 | PN-EN 1097-2:2020-09","norm_bases":["PN-EN 1097-2:2010","PN-EN 1097-2:2020-09"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Odporność na rozdrabnianie\nMetoda: Los Angeles PN-EN 1097-2:2010 | PN-EN 1097-2:2020-09 Kruszywa Odpornosc na rozdrabnianie\nMetoda: Los Angeles PN-EN 1097-2:2010 | PN-EN 1097-2:2020-09","categories":["other"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Resistance to fragmentation","search_en":"Aggregates Resistance to fragmentation Method: Los Angeles Civil Engineering Laboratory PN-EN 1097-2:2010 | PN-EN 1097-2:2020-09","technique_en":"Method: Los Angeles","test_object_en":"Aggregates","search_zh":"骨料 抗破碎性 方法：洛杉矶法 土木工程实验室 PN-EN 1097-2:2010 | PN-EN 1097-2:2020-09","test_object_zh":"骨料","lab_section_zh":"土木工程实验室","methodology_zh":"抗破碎性","technique_zh":"方法：洛杉矶法"},{"_id":"6a7d78df0636ba417e41a392","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Kruszywa","methodology":"Wskaźnik kształtu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik kształtu","reference":"PN-EN 933-4:2008","norm_bases":["PN-EN 933-4:2008"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Wskaźnik kształtu PN-EN 933-4:2008 Kruszywa Wskaznik ksztaltu PN-EN 933-4:2008","categories":["other"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Shape index","search_en":"Aggregates Shape index Civil Engineering Laboratory PN-EN 933-4:2008","test_object_en":"Aggregates","search_zh":"骨料 形状指数 土木工程实验室 PN-EN 933-4:2008","test_object_zh":"骨料","lab_section_zh":"土木工程实验室","methodology_zh":"形状指数"},{"_id":"6a7d78df0636ba417e41a393","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Kruszywa","methodology":"Bazaltowa zgorzel słoneczna","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Bazaltowa zgorzel słoneczna","reference":"PN-EN 1367-3:2002","norm_bases":["PN-EN 1367-3:2002"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Bazaltowa zgorzel słoneczna PN-EN 1367-3:2002 Kruszywa Bazaltowa zgorzel sloneczna PN-EN 1367-3:2002","categories":["other"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Basalt sunburn","search_en":"Aggregates Basalt sunburn Civil Engineering Laboratory PN-EN 1367-3:2002","test_object_en":"Aggregates","search_zh":"骨料 玄武岩日晒剥落 土木工程实验室 PN-EN 1367-3:2002","test_object_zh":"骨料","lab_section_zh":"土木工程实验室","methodology_zh":"玄武岩日晒剥落"},{"_id":"6a7d78df0636ba417e41a394","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Kruszywa","methodology":"Zawartość ziarn o powierzchniach powstałych w wyniku przekruszenia lub łamania","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość ziarn o powierzchniach powstałych w wyniku przekruszenia lub łamania","reference":"PN-EN 933-5:2000 | PN-EN 933-5:2023-05 | PN-EN 933-5:2000/A1:2005","norm_bases":["PN-EN 933-5:2000","PN-EN 933-5:2023-05","PN-EN 933-5:2000/A1:2005"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Zawartość ziarn o powierzchniach powstałych w wyniku przekruszenia lub łamania PN-EN 933-5:2000 | PN-EN 933-5:2023-05 | PN-EN 933-5:2000/A1:2005 Kruszywa Zawartosc ziarn o powierzchniach powstalych w wyniku przekruszenia lub lamania PN-EN 933-5:2000 | PN-EN 933-5:2023-05 | PN-EN 933-5:2000/A1:2005","categories":["other"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Content of particles with crushed or broken surfaces","search_en":"Aggregates Content of particles with crushed or broken surfaces Civil Engineering Laboratory PN-EN 933-5:2000 | PN-EN 933-5:2023-05 | PN-EN 933-5:2000/A1:2005","test_object_en":"Aggregates","search_zh":"骨料 经压碎或破碎形成表面的颗粒含量 土木工程实验室 PN-EN 933-5:2000 | PN-EN 933-5:2023-05 | PN-EN 933-5:2000/A1:2005","test_object_zh":"骨料","lab_section_zh":"土木工程实验室","methodology_zh":"经压碎或破碎形成表面的颗粒含量"},{"_id":"6a7d78df0636ba417e41a395","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Kruszywa","methodology":"Pobieranie próbek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek","reference":"PN-EN 932-1:1999 p.8.8","norm_bases":["PN-EN 932-1:1999 p.8.8"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Pobieranie próbek PN-EN 932-1:1999 p.8.8 Kruszywa Pobieranie probek PN-EN 932-1:1999 p.8.8","categories":["other"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Sampling","search_en":"Aggregates Sampling Civil Engineering Laboratory PN-EN 932-1:1999 p.8.8","test_object_en":"Aggregates","methodology_zh":"样品采集","search_zh":"骨料 样品采集 土木工程实验室 PN-EN 932-1:1999 p.8.8","test_object_zh":"骨料","lab_section_zh":"土木工程实验室"},{"_id":"6a7d78df0636ba417e41a396","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Warstwy konstrukcyjne nawierzchni","methodology":"Moduł odkształcenia","parameters":[{"name":"Zakres ciśnienia","range":"(0,02 – 0,45) MPa"},{"name":"Wskaźnik odkształcenia (z obliczeń)"}],"technique":"Metoda obciążeń płytą VSS","techniques":["Metoda obciążeń płytą VSS"],"computed":[],"activity":"Moduł odkształcenia\nZakres:\nZakres ciśnienia (0,02 – 0,45) MPa\nWskaźnik odkształcenia (z obliczeń)\nMetoda obciążeń płytą VSS","reference":"PN-S-02205:1998","norm_bases":["PN-S-02205:1998"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Warstwy konstrukcyjne nawierzchni Moduł odkształcenia\nZakres:\nZakres ciśnienia (0,02 – 0,45) MPa\nWskaźnik odkształcenia (z obliczeń)\nMetoda obciążeń płytą VSS PN-S-02205:1998 Warstwy konstrukcyjne nawierzchni Modul odksztalcenia\nZakres:\nZakres cisnienia (0,02 – 0,45) MPa\nWskaznik odksztalcenia (z obliczen)\nMetoda obciazen plyta VSS PN-S-02205:1998","categories":["other"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Deformation modulus","parameters_en":[{"name":"Pressure range","range":"(0,02 – 0,45) MPa"},{"name":"Deformation index (calculated)"}],"search_en":"Pavement structural layers Deformation modulus VSS plate loading method Civil Engineering Laboratory Pressure range Deformation index (calculated) PN-S-02205:1998","technique_en":"VSS plate loading method","test_object_en":"Pavement structural layers","lab_section_zh":"土木工程实验室","search_zh":"路面结构层 变形模量 VSS 平板荷载法 土木工程实验室 压力范围 PN-S-02205:1998","test_object_zh":"路面结构层","methodology_zh":"变形模量","technique_zh":"VSS 平板荷载法","parameters_zh":[{"name":"压力范围","range":"(0,02 – 0,45) MPa"},{"name":"Wskaźnik odkształcenia (z obliczeń)"}]},{"_id":"6a7d78df0636ba417e41a397","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Warstwy konstrukcyjne nawierzchni","methodology":"Dynamiczny moduł odkształcenia","parameters":[{"name":"Zakres","range":"Evd ≤125MN/m2"},{"name":"LWDT"}],"technique":"Metoda: obciążenia płytą dynamiczną","techniques":["Metoda: obciążenia płytą dynamiczną"],"computed":[],"activity":"Dynamiczny moduł odkształcenia\nZakres:\nZakres Evd ≤125MN/m2\nLWDT\nMetoda: obciążenia płytą dynamiczną","reference":"PBG 10, wersja 03, 26.03.2024","norm_bases":["PBG 10, wersja 03, 26.03.2024"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Warstwy konstrukcyjne nawierzchni Dynamiczny moduł odkształcenia\nZakres:\nZakres Evd ≤125MN/m2\nLWDT\nMetoda: obciążenia płytą dynamiczną PBG 10, wersja 03, 26.03.2024 Warstwy konstrukcyjne nawierzchni Dynamiczny modul odksztalcenia\nZakres:\nZakres Evd ≤125MN/m2\nLWDT\nMetoda: obciazenia plyta dynamiczna PBG 10, wersja 03, 26.03.2024","categories":["other"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Dynamic deformation modulus","parameters_en":[{"name":"Range","range":"Evd ≤125MN/m2"},{"name":"LWDT"}],"search_en":"Pavement structural layers Dynamic deformation modulus Method: dynamic plate loading Civil Engineering Laboratory Range LWDT PBG 10, wersja 03, 26.03.2024","technique_en":"Method: dynamic plate loading","test_object_en":"Pavement structural layers","parameters_zh":[{"name":"范围","range":"Evd ≤125MN/m2"},{"name":"轻型动力触探（LWDT）"}],"search_zh":"路面结构层 动态变形模量 土木工程实验室 范围 轻型动力触探（LWDT） PBG 10, wersja 03, 26.03.2024","lab_section_zh":"土木工程实验室","test_object_zh":"路面结构层","methodology_zh":"动态变形模量"},{"_id":"6a7d78df0636ba417e41a398","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Mieszanki związane spoiwem hydraulicznym","methodology":"Wytrzymałość na ściskanie stabilizacji","parameters":[{"name":"Zakres","range":"(2 - 50) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie stabilizacji\nZakres (2 - 50) kN","reference":"PBG 15, wersja 03, 09.01.2023 | PN-EN 13286-41:2022-04","norm_bases":["PBG 15, wersja 03, 09.01.2023","PN-EN 13286-41:2022-04"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki związane spoiwem hydraulicznym Wytrzymałość na ściskanie stabilizacji\nZakres (2 - 50) kN PBG 15, wersja 03, 09.01.2023 | PN-EN 13286-41:2022-04 Mieszanki zwiazane spoiwem hydraulicznym Wytrzymalosc na sciskanie stabilizacji\nZakres (2 - 50) kN PBG 15, wersja 03, 09.01.2023 | PN-EN 13286-41:2022-04","categories":["other"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Compressive strength of the stabilised mixture","parameters_en":[{"name":"Range","range":"(2 - 50) kN"}],"search_en":"Hydraulically bound mixtures Compressive strength of the stabilised mixture Civil Engineering Laboratory Range PBG 15, wersja 03, 09.01.2023 | PN-EN 13286-41:2022-04","test_object_en":"Hydraulically bound mixtures","parameters_zh":[{"name":"范围","range":"(2 - 50) kN"}],"search_zh":"水硬性胶结料结合的混合料 稳定土抗压强度 土木工程实验室 范围 PBG 15, wersja 03, 09.01.2023 | PN-EN 13286-41:2022-04","lab_section_zh":"土木工程实验室","test_object_zh":"水硬性胶结料结合的混合料","methodology_zh":"稳定土抗压强度"},{"_id":"6a7d78df0636ba417e41a399","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Mieszanki związane spoiwem hydraulicznym","methodology":"Pobór próbek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobór próbek","reference":"PN-EN 13286-1:2022-04","norm_bases":["PN-EN 13286-1:2022-04"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki związane spoiwem hydraulicznym Pobór próbek PN-EN 13286-1:2022-04 Mieszanki zwiazane spoiwem hydraulicznym Pobor probek PN-EN 13286-1:2022-04","categories":["other"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Sampling","search_en":"Hydraulically bound mixtures Sampling Civil Engineering Laboratory PN-EN 13286-1:2022-04","test_object_en":"Hydraulically bound mixtures","lab_section_zh":"土木工程实验室","search_zh":"水硬性胶结料结合的混合料 土木工程实验室 PN-EN 13286-1:2022-04","test_object_zh":"水硬性胶结料结合的混合料"},{"_id":"6a7d78df0636ba417e41a39a","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Mieszanki betonowe","methodology":"Zawartość powietrza","parameters":[],"technique":"Metoda ciśnieniomierza","techniques":["Metoda ciśnieniomierza"],"computed":[],"activity":"Zawartość powietrza\nMetoda ciśnieniomierza","reference":"PN-EN 12350-7:2011 | PN-EN 12350-7:2019-08","norm_bases":["PN-EN 12350-7:2011","PN-EN 12350-7:2019-08"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki betonowe Zawartość powietrza\nMetoda ciśnieniomierza PN-EN 12350-7:2011 | PN-EN 12350-7:2019-08 Mieszanki betonowe Zawartosc powietrza\nMetoda cisnieniomierza PN-EN 12350-7:2011 | PN-EN 12350-7:2019-08","categories":["construction"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Air content","search_en":"Fresh concrete mixes Air content Pressure gauge method Civil Engineering Laboratory PN-EN 12350-7:2011 | PN-EN 12350-7:2019-08","technique_en":"Pressure gauge method","test_object_en":"Fresh concrete mixes","methodology_zh":"含气量","search_zh":"混凝土拌合物 含气量 压力计法 土木工程实验室 PN-EN 12350-7:2011 | PN-EN 12350-7:2019-08","technique_zh":"压力计法","lab_section_zh":"土木工程实验室","test_object_zh":"混凝土拌合物"},{"_id":"6a7d78df0636ba417e41a39b","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Mieszanki betonowe","methodology":"Konsystencja","parameters":[],"technique":"Metoda opadu stożka","techniques":["Metoda opadu stożka"],"computed":[],"activity":"Konsystencja\nMetoda opadu stożka","reference":"PN-EN 12350-2:2011 | PN-EN 12350-2:2019-07","norm_bases":["PN-EN 12350-2:2011","PN-EN 12350-2:2019-07"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki betonowe Konsystencja\nMetoda opadu stożka PN-EN 12350-2:2011 | PN-EN 12350-2:2019-07 Mieszanki betonowe Konsystencja\nMetoda opadu stozka PN-EN 12350-2:2011 | PN-EN 12350-2:2019-07","categories":["construction"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Consistency","search_en":"Fresh concrete mixes Consistency Slump test method Civil Engineering Laboratory PN-EN 12350-2:2011 | PN-EN 12350-2:2019-07","technique_en":"Slump test method","test_object_en":"Fresh concrete mixes","methodology_zh":"稠度","search_zh":"混凝土拌合物 稠度 坍落度法 土木工程实验室 PN-EN 12350-2:2011 | PN-EN 12350-2:2019-07","technique_zh":"坍落度法","lab_section_zh":"土木工程实验室","test_object_zh":"混凝土拌合物"},{"_id":"6a7d78df0636ba417e41a39c","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Mieszanki betonowe","methodology":"Pobieranie próbek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek","reference":"PN-EN 12350-1:2011 | PN-EN 12350-1:2019-07","norm_bases":["PN-EN 12350-1:2011","PN-EN 12350-1:2019-07"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki betonowe Pobieranie próbek PN-EN 12350-1:2011 | PN-EN 12350-1:2019-07 Mieszanki betonowe Pobieranie probek PN-EN 12350-1:2011 | PN-EN 12350-1:2019-07","categories":["construction"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Sampling","search_en":"Fresh concrete mixes Sampling Civil Engineering Laboratory PN-EN 12350-1:2011 | PN-EN 12350-1:2019-07","test_object_en":"Fresh concrete mixes","methodology_zh":"样品采集","search_zh":"混凝土拌合物 样品采集 土木工程实验室 PN-EN 12350-1:2011 | PN-EN 12350-1:2019-07","lab_section_zh":"土木工程实验室","test_object_zh":"混凝土拌合物"},{"_id":"6a7d78df0636ba417e41a39d","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Beton","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres siły","range":"(100 - 2000) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres siły (100 - 2000) kN","reference":"PN-EN 12390-3:2011 | PN-EN 12390-3:2011 / AC: 2012 | PN-EN 12390-3:2019-07","norm_bases":["PN-EN 12390-3:2011","PN-EN 12390-3:2011 / AC: 2012","PN-EN 12390-3:2019-07"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Wytrzymałość na ściskanie\nZakres siły (100 - 2000) kN PN-EN 12390-3:2011 | PN-EN 12390-3:2011 / AC: 2012 | PN-EN 12390-3:2019-07 Beton Wytrzymalosc na sciskanie\nZakres sily (100 - 2000) kN PN-EN 12390-3:2011 | PN-EN 12390-3:2011 / AC: 2012 | PN-EN 12390-3:2019-07","categories":["construction"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Compressive strength","parameters_en":[{"name":"Force range","range":"(100 - 2000) kN"}],"search_en":"Concrete Compressive strength Civil Engineering Laboratory Force range PN-EN 12390-3:2011 | PN-EN 12390-3:2011 / AC: 2012 | PN-EN 12390-3:2019-07","test_object_en":"Concrete","methodology_zh":"抗压强度","parameters_zh":[{"name":"力值范围","range":"(100 - 2000) kN"}],"search_zh":"混凝土 抗压强度 土木工程实验室 力值范围 PN-EN 12390-3:2011 | PN-EN 12390-3:2011 / AC: 2012 | PN-EN 12390-3:2019-07","test_object_zh":"混凝土","lab_section_zh":"土木工程实验室"},{"_id":"6a7d78df0636ba417e41a39e","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Beton","methodology":"Nasiąkliwość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Nasiąkliwość","reference":"PN-B-06250:1988","norm_bases":["PN-B-06250:1988"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Nasiąkliwość PN-B-06250:1988 Beton Nasiakliwosc PN-B-06250:1988","categories":["construction"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Water absorption","search_en":"Concrete Water absorption Civil Engineering Laboratory PN-B-06250:1988","test_object_en":"Concrete","methodology_zh":"吸水率","search_zh":"混凝土 吸水率 土木工程实验室 PN-B-06250:1988","test_object_zh":"混凝土","lab_section_zh":"土木工程实验室"},{"_id":"6a7d78df0636ba417e41a39f","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Beton","methodology":"Mrozoodporność","parameters":[],"technique":"Metoda zwykła","techniques":["Metoda zwykła"],"computed":[],"activity":"Mrozoodporność\nMetoda zwykła","reference":"PN-B-06250:1988","norm_bases":["PN-B-06250:1988"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Mrozoodporność\nMetoda zwykła PN-B-06250:1988 Beton Mrozoodpornosc\nMetoda zwykla PN-B-06250:1988","categories":["construction"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Frost resistance","search_en":"Concrete Frost resistance Ordinary method Civil Engineering Laboratory PN-B-06250:1988","technique_en":"Ordinary method","test_object_en":"Concrete","search_zh":"混凝土 抗冻性 常规法 土木工程实验室 PN-B-06250:1988","test_object_zh":"混凝土","lab_section_zh":"土木工程实验室","methodology_zh":"抗冻性","technique_zh":"常规法"},{"_id":"6a7d78df0636ba417e41a3a0","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Beton","methodology":"Przepuszczalność wody przez beton","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Przepuszczalność wody przez beton","reference":"PN-B-06250:1988","norm_bases":["PN-B-06250:1988"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Przepuszczalność wody przez beton PN-B-06250:1988 Beton Przepuszczalnosc wody przez beton PN-B-06250:1988","categories":["water","construction"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Water permeability of concrete","search_en":"Concrete Water permeability of concrete Civil Engineering Laboratory PN-B-06250:1988","test_object_en":"Concrete","search_zh":"混凝土 混凝土透水性 土木工程实验室 PN-B-06250:1988","test_object_zh":"混凝土","lab_section_zh":"土木工程实验室","methodology_zh":"混凝土透水性"},{"_id":"6a7d78df0636ba417e41a3a1","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Beton","methodology":"Głębokość penetracji wody pod ciśnieniem","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Głębokość penetracji wody pod ciśnieniem","reference":"PN-EN 12390-8:2011 | PN-EN 12390-8:2019-08","norm_bases":["PN-EN 12390-8:2011","PN-EN 12390-8:2019-08"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Głębokość penetracji wody pod ciśnieniem PN-EN 12390-8:2011 | PN-EN 12390-8:2019-08 Beton Glebokosc penetracji wody pod cisnieniem PN-EN 12390-8:2011 | PN-EN 12390-8:2019-08","categories":["water","construction"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Depth of penetration of water under pressure","search_en":"Concrete Depth of penetration of water under pressure Civil Engineering Laboratory PN-EN 12390-8:2011 | PN-EN 12390-8:2019-08","test_object_en":"Concrete","methodology_zh":"压力水渗透深度","search_zh":"混凝土 压力水渗透深度 土木工程实验室 PN-EN 12390-8:2011 | PN-EN 12390-8:2019-08","test_object_zh":"混凝土","lab_section_zh":"土木工程实验室"},{"_id":"6a7d78df0636ba417e41a3a2","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Beton w konstrukcjach","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres","range":"(100 - 2000) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres (100 - 2000) kN","reference":"PN-EN 12504-1:2011 | PN-EN 12504-1:2019-08 | PN-EN 12390-3:2011 | PN-EN 12390-3:2011 / AC:2012 | PN-EN 12390-3:2019-07","norm_bases":["PN-EN 12504-1:2011","PN-EN 12504-1:2019-08","PN-EN 12390-3:2011","PN-EN 12390-3:2011 / AC:2012","PN-EN 12390-3:2019-07"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton w konstrukcjach Wytrzymałość na ściskanie\nZakres (100 - 2000) kN PN-EN 12504-1:2011 | PN-EN 12504-1:2019-08 | PN-EN 12390-3:2011 | PN-EN 12390-3:2011 / AC:2012 | PN-EN 12390-3:2019-07 Beton w konstrukcjach Wytrzymalosc na sciskanie\nZakres (100 - 2000) kN PN-EN 12504-1:2011 | PN-EN 12504-1:2019-08 | PN-EN 12390-3:2011 | PN-EN 12390-3:2011 / AC:2012 | PN-EN 12390-3:2019-07","categories":["construction"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Compressive strength","parameters_en":[{"name":"Range","range":"(100 - 2000) kN"}],"search_en":"Concrete in structures Compressive strength Civil Engineering Laboratory Range PN-EN 12504-1:2011 | PN-EN 12504-1:2019-08 | PN-EN 12390-3:2011 | PN-EN 12390-3:2011 / AC:2012 | PN-EN 12390-3:2019-07","test_object_en":"Concrete in structures","methodology_zh":"抗压强度","parameters_zh":[{"name":"范围","range":"(100 - 2000) kN"}],"search_zh":"结构中的混凝土 抗压强度 土木工程实验室 范围 PN-EN 12504-1:2011 | PN-EN 12504-1:2019-08 | PN-EN 12390-3:2011 | PN-EN 12390-3:2011 / AC:2012 | PN-EN 12390-3:2019-07","lab_section_zh":"土木工程实验室","test_object_zh":"结构中的混凝土"},{"_id":"6a7d78df0636ba417e41a3a3","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Beton w konstrukcjach","methodology":"Nasiąkliwość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Nasiąkliwość","reference":"PN-B-06250:1988","norm_bases":["PN-B-06250:1988"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton w konstrukcjach Nasiąkliwość PN-B-06250:1988 Beton w konstrukcjach Nasiakliwosc PN-B-06250:1988","categories":["construction"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Water absorption","search_en":"Concrete in structures Water absorption Civil Engineering Laboratory PN-B-06250:1988","test_object_en":"Concrete in structures","methodology_zh":"吸水率","search_zh":"结构中的混凝土 吸水率 土木工程实验室 PN-B-06250:1988","lab_section_zh":"土木工程实验室","test_object_zh":"结构中的混凝土"},{"_id":"6a7d78df0636ba417e41a3a4","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Beton w konstrukcjach","methodology":"Mrozoodporność","parameters":[],"technique":"Metoda zwykła","techniques":["Metoda zwykła"],"computed":[],"activity":"Mrozoodporność\nMetoda zwykła","reference":"PN-B-06250:1988","norm_bases":["PN-B-06250:1988"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton w konstrukcjach Mrozoodporność\nMetoda zwykła PN-B-06250:1988 Beton w konstrukcjach Mrozoodpornosc\nMetoda zwykla PN-B-06250:1988","categories":["construction"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Frost resistance","search_en":"Concrete in structures Frost resistance Ordinary method Civil Engineering Laboratory PN-B-06250:1988","technique_en":"Ordinary method","test_object_en":"Concrete in structures","lab_section_zh":"土木工程实验室","search_zh":"结构中的混凝土 抗冻性 常规法 土木工程实验室 PN-B-06250:1988","methodology_zh":"抗冻性","technique_zh":"常规法","test_object_zh":"结构中的混凝土"},{"_id":"6a7d78df0636ba417e41a3a5","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Beton w konstrukcjach","methodology":"Pobieranie próbek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek","reference":"PN-EN 12504-1:2011 | PN-EN 12504-1:2019-08","norm_bases":["PN-EN 12504-1:2011","PN-EN 12504-1:2019-08"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton w konstrukcjach Pobieranie próbek PN-EN 12504-1:2011 | PN-EN 12504-1:2019-08 Beton w konstrukcjach Pobieranie probek PN-EN 12504-1:2011 | PN-EN 12504-1:2019-08","categories":["construction"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Sampling","search_en":"Concrete in structures Sampling Civil Engineering Laboratory PN-EN 12504-1:2011 | PN-EN 12504-1:2019-08","test_object_en":"Concrete in structures","methodology_zh":"样品采集","search_zh":"结构中的混凝土 样品采集 土木工程实验室 PN-EN 12504-1:2011 | PN-EN 12504-1:2019-08","lab_section_zh":"土木工程实验室","test_object_zh":"结构中的混凝土"},{"_id":"6a7d78df0636ba417e41a3a6","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Wyroby i systemy do ochrony i napraw konstrukcji betonowych","methodology":"Wytrzymałość na odrywanie","parameters":[{"name":"Zakres","range":"(1 - 16) kN"},{"name":"Przyczepność [MPa] (z obliczeń)"}],"technique":"Metoda pull-off","techniques":["Metoda pull-off"],"computed":[],"activity":"Wytrzymałość na odrywanie\nZakres:\nZakres (1 - 16) kN\nPrzyczepność [MPa] (z obliczeń)\nMetoda pull-off","reference":"PN-EN 1542:2000","norm_bases":["PN-EN 1542:2000"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i systemy do ochrony i napraw konstrukcji betonowych Wytrzymałość na odrywanie\nZakres:\nZakres (1 - 16) kN\nPrzyczepność [MPa] (z obliczeń)\nMetoda pull-off PN-EN 1542:2000 Wyroby i systemy do ochrony i napraw konstrukcji betonowych Wytrzymalosc na odrywanie\nZakres:\nZakres (1 - 16) kN\nPrzyczepnosc [MPa] (z obliczen)\nMetoda pull-off PN-EN 1542:2000","categories":["construction"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Pull-off strength","parameters_en":[{"name":"Range","range":"(1 - 16) kN"},{"name":"Adhesion [MPa] (calculated)"}],"search_en":"Products and systems for the protection and repair of concrete structures Pull-off strength Pull-off method Civil Engineering Laboratory Range Adhesion [MPa] (calculated) PN-EN 1542:2000","technique_en":"Pull-off method","test_object_en":"Products and systems for the protection and repair of concrete structures","parameters_zh":[{"name":"范围","range":"(1 - 16) kN"},{"name":"Przyczepność [MPa] (z obliczeń)"}],"search_zh":"混凝土结构防护与修复制品与系统 拉拔强度 拉拔法 土木工程实验室 范围 PN-EN 1542:2000","lab_section_zh":"土木工程实验室","technique_zh":"拉拔法","test_object_zh":"混凝土结构防护与修复制品与系统","methodology_zh":"拉拔强度"},{"_id":"6a7d78df0636ba417e41a3a7","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Mieszanki mineralno-asfaltowe","methodology":"Gęstość w wodzie","parameters":[],"technique":"Metoda: A","techniques":["Metoda: A"],"computed":[],"activity":"Gęstość w wodzie\nMetoda: A","reference":"PN-EN 12697-5:2010 | PN-EN 12697-5:2010 / AC:2012 | PN-EN 12697-5:2019-01","norm_bases":["PN-EN 12697-5:2010","PN-EN 12697-5:2010 / AC:2012","PN-EN 12697-5:2019-01"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno-asfaltowe Gęstość w wodzie\nMetoda: A PN-EN 12697-5:2010 | PN-EN 12697-5:2010 / AC:2012 | PN-EN 12697-5:2019-01 Mieszanki mineralno-asfaltowe Gestosc w wodzie\nMetoda: A PN-EN 12697-5:2010 | PN-EN 12697-5:2010 / AC:2012 | PN-EN 12697-5:2019-01","categories":["other"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Density in water","search_en":"Bituminous mixtures Density in water Method: A Civil Engineering Laboratory PN-EN 12697-5:2010 | PN-EN 12697-5:2010 / AC:2012 | PN-EN 12697-5:2019-01","technique_en":"Method: A","test_object_en":"Bituminous mixtures","lab_section_zh":"土木工程实验室","search_zh":"沥青混合料 水中密度 方法：A 土木工程实验室 PN-EN 12697-5:2010 | PN-EN 12697-5:2010 / AC:2012 | PN-EN 12697-5:2019-01","test_object_zh":"沥青混合料","methodology_zh":"水中密度","technique_zh":"方法：A"},{"_id":"6a7d78df0636ba417e41a3a8","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Mieszanki mineralno-asfaltowe","methodology":"Gęstość objętościowa","parameters":[],"technique":"Metoda: B","techniques":["Metoda: B"],"computed":[],"activity":"Gęstość objętościowa\nMetoda: B","reference":"PN-EN 12697-6:2012 | PN-EN 12697-6:2020-07","norm_bases":["PN-EN 12697-6:2012","PN-EN 12697-6:2020-07"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno-asfaltowe Gęstość objętościowa\nMetoda: B PN-EN 12697-6:2012 | PN-EN 12697-6:2020-07 Mieszanki mineralno-asfaltowe Gestosc objetosciowa\nMetoda: B PN-EN 12697-6:2012 | PN-EN 12697-6:2020-07","categories":["other"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Bulk density","search_en":"Bituminous mixtures Bulk density Method: B Civil Engineering Laboratory PN-EN 12697-6:2012 | PN-EN 12697-6:2020-07","technique_en":"Method: B","test_object_en":"Bituminous mixtures","lab_section_zh":"土木工程实验室","search_zh":"沥青混合料 堆积密度 方法：B 土木工程实验室 PN-EN 12697-6:2012 | PN-EN 12697-6:2020-07","test_object_zh":"沥青混合料","methodology_zh":"堆积密度","technique_zh":"方法：B"},{"_id":"6a7d78df0636ba417e41a3a9","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Mieszanki mineralno-asfaltowe","methodology":"Oznaczanie zawartości wolnej przestrzeni (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Oznaczanie zawartości wolnej przestrzeni (z obliczeń)","reference":"PN-EN 12697-8:2005 | PN-EN 12697-8:2019-01","norm_bases":["PN-EN 12697-8:2005","PN-EN 12697-8:2019-01"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno-asfaltowe Oznaczanie zawartości wolnej przestrzeni (z obliczeń) PN-EN 12697-8:2005 | PN-EN 12697-8:2019-01 Mieszanki mineralno-asfaltowe Oznaczanie zawartosci wolnej przestrzeni (z obliczen) PN-EN 12697-8:2005 | PN-EN 12697-8:2019-01","categories":["other"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Determination of void content (calculated)","search_en":"Bituminous mixtures Determination of void content (calculated) Civil Engineering Laboratory PN-EN 12697-8:2005 | PN-EN 12697-8:2019-01","test_object_en":"Bituminous mixtures","lab_section_zh":"土木工程实验室","search_zh":"沥青混合料 土木工程实验室 PN-EN 12697-8:2005 | PN-EN 12697-8:2019-01","test_object_zh":"沥青混合料"},{"_id":"6a7d78df0636ba417e41a3aa","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Mieszanki mineralno-asfaltowe","methodology":"Zawartość lepiszcza rozpuszczalnego","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość lepiszcza rozpuszczalnego","reference":"PN-EN 12697-1:2012 | PN-EN 12697-1:2020-08","norm_bases":["PN-EN 12697-1:2012","PN-EN 12697-1:2020-08"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno-asfaltowe Zawartość lepiszcza rozpuszczalnego PN-EN 12697-1:2012 | PN-EN 12697-1:2020-08 Mieszanki mineralno-asfaltowe Zawartosc lepiszcza rozpuszczalnego PN-EN 12697-1:2012 | PN-EN 12697-1:2020-08","categories":["other"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Soluble binder content","search_en":"Bituminous mixtures Soluble binder content Civil Engineering Laboratory PN-EN 12697-1:2012 | PN-EN 12697-1:2020-08","test_object_en":"Bituminous mixtures","lab_section_zh":"土木工程实验室","search_zh":"沥青混合料 可溶性胶结料含量 土木工程实验室 PN-EN 12697-1:2012 | PN-EN 12697-1:2020-08","test_object_zh":"沥青混合料","methodology_zh":"可溶性胶结料含量"},{"_id":"6a7d78df0636ba417e41a3ab","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Mieszanki mineralno-asfaltowe","methodology":"Skład ziarnowy","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skład ziarnowy","reference":"PN-EN 12697-2:2015-06 | PN-EN 12697-2+A1:2019-12","norm_bases":["PN-EN 12697-2:2015-06","PN-EN 12697-2+A1:2019-12"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno-asfaltowe Skład ziarnowy PN-EN 12697-2:2015-06 | PN-EN 12697-2+A1:2019-12 Mieszanki mineralno-asfaltowe Sklad ziarnowy PN-EN 12697-2:2015-06 | PN-EN 12697-2+A1:2019-12","categories":["other"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Particle size distribution","search_en":"Bituminous mixtures Particle size distribution Civil Engineering Laboratory PN-EN 12697-2:2015-06 | PN-EN 12697-2+A1:2019-12","test_object_en":"Bituminous mixtures","lab_section_zh":"土木工程实验室","methodology_zh":"粒度分布","search_zh":"沥青混合料 粒度分布 土木工程实验室 PN-EN 12697-2:2015-06 | PN-EN 12697-2+A1:2019-12","test_object_zh":"沥青混合料"},{"_id":"6a7d78df0636ba417e41a3ac","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Mieszanki mineralno-asfaltowe","methodology":"Pobieranie próbek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek","reference":"PN-EN 12697-27:2005 p. 4.3 (spod ślimaka rozkładarki) p. 4.7 (odwiert) | PN-EN 12697-27:2005+Ap1:2013 | PN-EN 12697-27:2017-07","norm_bases":["PN-EN 12697-27:2005 p. 4.3 (spod ślimaka rozkładarki) p. 4.7 (odwiert)","PN-EN 12697-27:2005+Ap1:2013","PN-EN 12697-27:2017-07"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno-asfaltowe Pobieranie próbek PN-EN 12697-27:2005 p. 4.3 (spod ślimaka rozkładarki) p. 4.7 (odwiert) | PN-EN 12697-27:2005+Ap1:2013 | PN-EN 12697-27:2017-07 Mieszanki mineralno-asfaltowe Pobieranie probek PN-EN 12697-27:2005 p. 4.3 (spod slimaka rozkladarki) p. 4.7 (odwiert) | PN-EN 12697-27:2005+Ap1:2013 | PN-EN 12697-27:2017-07","categories":["other"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Sampling","search_en":"Bituminous mixtures Sampling Civil Engineering Laboratory PN-EN 12697-27:2005 p. 4.3 (spod ślimaka rozkładarki) p. 4.7 (odwiert) | PN-EN 12697-27:2005+Ap1:2013 | PN-EN 12697-27:2017-07","test_object_en":"Bituminous mixtures","methodology_zh":"样品采集","search_zh":"沥青混合料 样品采集 土木工程实验室 PN-EN 12697-27:2005 p. 4.3 (spod ślimaka rozkładarki) p. 4.7 (odwiert) | PN-EN 12697-27:2005+Ap1:2013 | PN-EN 12697-27:2017-07","lab_section_zh":"土木工程实验室","test_object_zh":"沥青混合料"},{"_id":"6a7d78df0636ba417e41a3ad","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Nawierzchnie asfaltowe","methodology":"Grubość warstwy","parameters":[{"name":"Zakres","range":"(0-1000) mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Grubość warstwy\nZakres (0-1000) mm","reference":"PN-EN 12697-36:2005 p. 4.1 | PN-EN 12697-36:2022-09 p. 6.1","norm_bases":["PN-EN 12697-36:2005 p. 4.1","PN-EN 12697-36:2022-09 p. 6.1"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawierzchnie asfaltowe Grubość warstwy\nZakres (0-1000) mm PN-EN 12697-36:2005 p. 4.1 | PN-EN 12697-36:2022-09 p. 6.1 Nawierzchnie asfaltowe Grubosc warstwy\nZakres (0-1000) mm PN-EN 12697-36:2005 p. 4.1 | PN-EN 12697-36:2022-09 p. 6.1","categories":["other"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Layer thickness","parameters_en":[{"name":"Range","range":"(0-1000) mm"}],"search_en":"Asphalt pavements Layer thickness Civil Engineering Laboratory Range PN-EN 12697-36:2005 p. 4.1 | PN-EN 12697-36:2022-09 p. 6.1","test_object_en":"Asphalt pavements","parameters_zh":[{"name":"范围","range":"(0-1000) mm"}],"search_zh":"层厚 土木工程实验室 范围 PN-EN 12697-36:2005 p. 4.1 | PN-EN 12697-36:2022-09 p. 6.1","lab_section_zh":"土木工程实验室","methodology_zh":"层厚"},{"_id":"6a7d78df0636ba417e41a3ae","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Powłoki malarskie","methodology":"Grubość powłok","parameters":[{"name":"Zakres","range":"(0 - 500) μm"}],"technique":"Metoda 7C i 7D","techniques":["Metoda 7C i 7D"],"computed":[],"activity":"Grubość powłok\nZakres (0 - 500) μm\nMetoda 7C i 7D","reference":"PN-EN ISO 2808:2008","norm_bases":["PN-EN ISO 2808:2008"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Powłoki malarskie Grubość powłok\nZakres (0 - 500) μm\nMetoda 7C i 7D PN-EN ISO 2808:2008 Powloki malarskie Grubosc powlok\nZakres (0 - 500) μm\nMetoda 7C i 7D PN-EN ISO 2808:2008","categories":["other"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Thickness of coatings","parameters_en":[{"name":"Range","range":"(0 - 500) μm"}],"search_en":"Paint coatings Thickness of coatings Method 7C and 7D Civil Engineering Laboratory Range PN-EN ISO 2808:2008","technique_en":"Method 7C and 7D","test_object_en":"Paint coatings","parameters_zh":[{"name":"范围","range":"(0 - 500) μm"}],"search_zh":"土木工程实验室 范围 PN-EN ISO 2808:2008","lab_section_zh":"土木工程实验室"},{"_id":"6a7d78df0636ba417e41a3af","lab_id":"69ad52a3de79e566650fb5a8","country":"PL","accr_number":"AB 1110","accr_body":"PCA","test_object":"Powłoki malarskie","methodology":"Grubość powłok","parameters":[{"name":"Zakres","range":"(0 - 500) μm"}],"technique":"Metoda 7B.2 i 7C","techniques":["Metoda 7B.2 i 7C"],"computed":[],"activity":"Grubość powłok\nZakres (0 - 500) μm\nMetoda 7B.2 i 7C","reference":"PN-EN ISO 2808:2020-01","norm_bases":["PN-EN ISO 2808:2020-01"],"lab_section":"Laboratorium Inżynierii Lądowej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Powłoki malarskie Grubość powłok\nZakres (0 - 500) μm\nMetoda 7B.2 i 7C PN-EN ISO 2808:2020-01 Powloki malarskie Grubosc powlok\nZakres (0 - 500) μm\nMetoda 7B.2 i 7C PN-EN ISO 2808:2020-01","categories":["other"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Civil Engineering Laboratory","methodology_en":"Thickness of coatings","parameters_en":[{"name":"Range","range":"(0 - 500) μm"}],"search_en":"Paint coatings Thickness of coatings Method 7B.2 and 7C Civil Engineering Laboratory Range PN-EN ISO 2808:2020-01","technique_en":"Method 7B.2 and 7C","test_object_en":"Paint coatings","parameters_zh":[{"name":"范围","range":"(0 - 500) μm"}],"search_zh":"土木工程实验室 范围 PN-EN ISO 2808:2020-01","lab_section_zh":"土木工程实验室"}],"has_pdf":true}