{"lab":{"_id":"69ad52a3de79e566650fb5a0","accr_number":"AB 1106","country":"PL","accr_body":"PCA","address":"ul. Instytutowa 1, 03-302 Warszawa, PRACOWNIA MOSTÓW I URZĄDZEŃ ODWADNIAJĄCYCH, 55-140 Żmigród","categories":["construction","materials"],"city":"Żmigród","imported_at":"2026-03-08T10:42:43.265Z","methods_count":9,"name":"INSTYTUT BADAWCZY DRÓG I MOSTÓW","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1106.pdf"],"scope_summary":"","search_text":"instytut badawczy dróg i mostów ul. instytutowa 1, 03-302 warszawa, pracownia mostów i urządzeń odwadniających, 55-140 żmigród other construction materials","status":"active","updated_at":"2026-03-08T14:50:17.237Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:17.237Z","parse_date":"2026-07-17T16:18:52.307Z","parse_source":"m5-mistral-qa","email_confidence":"high","email_mx":true,"email_source":"https://www.ibdim.edu.pl/pl/kontakt","fields_of_testing":[{"codes":"J/5","pl":"Badania mechaniczne materiałów i wyrobów budowlanych","en":"Mechanical Tests of building products, building materials"},{"codes":"N/5","pl":"Badania właściwości fizycznych materiałów budowlanych","en":"Tests of physical properities of building materials"}],"issue":{"no":"16","date":"07.10.2025"},"map_coord":[51.471739,16.908272],"map_geo":"nominatim-city","has_en":true,"category_counts":{"construction":8,"materials":6,"other":1},"category_scores":{"construction":4.27,"materials":2.4,"other":0.07},"has_zh":true},"methods":[{"_id":"6a5a55ec9af9f73f3825005b","lab_id":"69ad52a3de79e566650fb5a0","country":"PL","accr_number":"AB 1106","accr_body":"PCA","test_object":"Studzienki włazowe i niewłazowe z betonu niezbrojonego, z betonu zbrojonego włóknem stalowym i żelbetowe","test_object_en":"Manholes and inspection chambers of unreinforced concrete, steel fibre reinforced concrete and reinforced concrete","methodology":"Wytrzymałość na pionowe obciążenie Zakres siły: (20-900) kN","methodology_en":"Resistance to vertical load Force range: (20-900) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na pionowe obciążenie Zakres siły: (20-900) kN","reference":"PN-EN 1917:2004 PN-EN 1917:2004/AC:2009 Załącznik B","norm_bases":["PN-EN 1917:2004 PN-EN 1917:2004/AC:2009 Załącznik B"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Studzienki włazowe i niewłazowe z betonu niezbrojonego, z betonu zbrojonego włóknem stalowym i żelbetowe Wytrzymałość na pionowe obciążenie Zakres siły: (20-900) kN PN-EN 1917:2004 PN-EN 1917:2004/AC:2009 Załącznik B Studzienki wlazowe i niewlazowe z betonu niezbrojonego, z betonu zbrojonego wloknem stalowym i zelbetowe Wytrzymalosc na pionowe obciazenie Zakres sily: (20-900) kN PN-EN 1917:2004 PN-EN 1917:2004/AC:2009 Zalacznik B","categories":["construction","materials"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Manholes and inspection chambers of unreinforced concrete, steel fibre reinforced concrete and reinforced concrete Resistance to vertical load Force range: (20-900) kN PN-EN 1917:2004 PN-EN 1917:2004/AC:2009 Załącznik B","search_zh":"素混凝土、钢纤维混凝土与钢筋混凝土的可进入式与不可进入式检查井 PN-EN 1917:2004 PN-EN 1917:2004/AC:2009 Załącznik B","test_object_zh":"素混凝土、钢纤维混凝土与钢筋混凝土的可进入式与不可进入式检查井"},{"_id":"6a5a55ec9af9f73f3825005c","lab_id":"69ad52a3de79e566650fb5a0","country":"PL","accr_number":"AB 1106","accr_body":"PCA","test_object":"Studzienki włazowe i niewłazowe z betonu niezbrojonego, z betonu zbrojonego włóknem stalowym i żelbetowe","test_object_en":"Manholes and inspection chambers of unreinforced concrete, steel fibre reinforced concrete and reinforced concrete","methodology":"Wytrzymałość na zgniatanie elementów Zakres siły: (20-900) kN","methodology_en":"Crushing strength of the elements Force range: (20-900) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na zgniatanie elementów Zakres siły: (20-900) kN","reference":"PN-EN 1917:2004 PN-EN 1917:2004/AC:2009 Załącznik A","norm_bases":["PN-EN 1917:2004 PN-EN 1917:2004/AC:2009 Załącznik A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Studzienki włazowe i niewłazowe z betonu niezbrojonego, z betonu zbrojonego włóknem stalowym i żelbetowe Wytrzymałość na zgniatanie elementów Zakres siły: (20-900) kN PN-EN 1917:2004 PN-EN 1917:2004/AC:2009 Załącznik A Studzienki wlazowe i niewlazowe z betonu niezbrojonego, z betonu zbrojonego wloknem stalowym i zelbetowe Wytrzymalosc na zgniatanie elementow Zakres sily: (20-900) kN PN-EN 1917:2004 PN-EN 1917:2004/AC:2009 Zalacznik A","categories":["construction","materials"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Manholes and inspection chambers of unreinforced concrete, steel fibre reinforced concrete and reinforced concrete Crushing strength of the elements Force range: (20-900) kN PN-EN 1917:2004 PN-EN 1917:2004/AC:2009 Załącznik A","search_zh":"素混凝土、钢纤维混凝土与钢筋混凝土的可进入式与不可进入式检查井 PN-EN 1917:2004 PN-EN 1917:2004/AC:2009 Załącznik A","test_object_zh":"素混凝土、钢纤维混凝土与钢筋混凝土的可进入式与不可进入式检查井"},{"_id":"6a5a55ec9af9f73f3825005d","lab_id":"69ad52a3de79e566650fb5a0","country":"PL","accr_number":"AB 1106","accr_body":"PCA","test_object":"Studzienki włazowe i niewłazowe z betonu niezbrojonego, z betonu zbrojonego włóknem stalowym i żelbetowe","test_object_en":"Manholes and inspection chambers of unreinforced concrete, steel fibre reinforced concrete and reinforced concrete","methodology":"Nasiąkliwość wodą","methodology_en":"Water absorption","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nasiąkliwość wodą","reference":"PN-EN 1917:2004 PN-EN 1917:2004/AC:2009 Załącznik D","norm_bases":["PN-EN 1917:2004 PN-EN 1917:2004/AC:2009 Załącznik D"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Studzienki włazowe i niewłazowe z betonu niezbrojonego, z betonu zbrojonego włóknem stalowym i żelbetowe Nasiąkliwość wodą PN-EN 1917:2004 PN-EN 1917:2004/AC:2009 Załącznik D Studzienki wlazowe i niewlazowe z betonu niezbrojonego, z betonu zbrojonego wloknem stalowym i zelbetowe Nasiakliwosc woda PN-EN 1917:2004 PN-EN 1917:2004/AC:2009 Zalacznik D","categories":["construction","materials"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Manholes and inspection chambers of unreinforced concrete, steel fibre reinforced concrete and reinforced concrete Water absorption PN-EN 1917:2004 PN-EN 1917:2004/AC:2009 Załącznik D","search_zh":"素混凝土、钢纤维混凝土与钢筋混凝土的可进入式与不可进入式检查井 PN-EN 1917:2004 PN-EN 1917:2004/AC:2009 Załącznik D","test_object_zh":"素混凝土、钢纤维混凝土与钢筋混凝土的可进入式与不可进入式检查井"},{"_id":"6a5a55ec9af9f73f3825005e","lab_id":"69ad52a3de79e566650fb5a0","country":"PL","accr_number":"AB 1106","accr_body":"PCA","test_object":"Studzienki włazowe i niewłazowe z betonu niezbrojonego, z betonu zbrojonego włóknem stalowym i żelbetowe","test_object_en":"Manholes and inspection chambers of unreinforced concrete, steel fibre reinforced concrete and reinforced concrete","methodology":"Zamocowanie stopni złazowych. Próba obciążenia pionowego Zakres siły: (1-8) kN","methodology_en":"Fixing of step irons. Vertical load test Force range: (1-8) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zamocowanie stopni złazowych. Próba obciążenia pionowego Zakres siły: (1-8) kN","reference":"PN-EN 1917:2004 Załącznik E","norm_bases":["PN-EN 1917:2004 Załącznik E"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Studzienki włazowe i niewłazowe z betonu niezbrojonego, z betonu zbrojonego włóknem stalowym i żelbetowe Zamocowanie stopni złazowych. Próba obciążenia pionowego Zakres siły: (1-8) kN PN-EN 1917:2004 Załącznik E Studzienki wlazowe i niewlazowe z betonu niezbrojonego, z betonu zbrojonego wloknem stalowym i zelbetowe Zamocowanie stopni zlazowych. Proba obciazenia pionowego Zakres sily: (1-8) kN PN-EN 1917:2004 Zalacznik E","categories":["construction","materials"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Manholes and inspection chambers of unreinforced concrete, steel fibre reinforced concrete and reinforced concrete Fixing of step irons. Vertical load test Force range: (1-8) kN PN-EN 1917:2004 Załącznik E","search_zh":"素混凝土、钢纤维混凝土与钢筋混凝土的可进入式与不可进入式检查井 PN-EN 1917:2004 Załącznik E","test_object_zh":"素混凝土、钢纤维混凝土与钢筋混凝土的可进入式与不可进入式检查井"},{"_id":"6a5a55ec9af9f73f3825005f","lab_id":"69ad52a3de79e566650fb5a0","country":"PL","accr_number":"AB 1106","accr_body":"PCA","test_object":"Studzienki włazowe i niewłazowe z betonu niezbrojonego, z betonu zbrojonego włóknem stalowym i żelbetowe","test_object_en":"Manholes and inspection chambers of unreinforced concrete, steel fibre reinforced concrete and reinforced concrete","methodology":"Zamocowanie stopni złazowych. Próba poziomego wyrywania Zakres siły: (1-8) kN","methodology_en":"Fixing of step irons. Horizontal pull-out test Force range: (1-8) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zamocowanie stopni złazowych. Próba poziomego wyrywania Zakres siły: (1-8) kN","reference":"PN-EN 1917:2004 Załącznik E","norm_bases":["PN-EN 1917:2004 Załącznik E"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Studzienki włazowe i niewłazowe z betonu niezbrojonego, z betonu zbrojonego włóknem stalowym i żelbetowe Zamocowanie stopni złazowych. Próba poziomego wyrywania Zakres siły: (1-8) kN PN-EN 1917:2004 Załącznik E Studzienki wlazowe i niewlazowe z betonu niezbrojonego, z betonu zbrojonego wloknem stalowym i zelbetowe Zamocowanie stopni zlazowych. Proba poziomego wyrywania Zakres sily: (1-8) kN PN-EN 1917:2004 Zalacznik E","categories":["construction","materials"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Manholes and inspection chambers of unreinforced concrete, steel fibre reinforced concrete and reinforced concrete Fixing of step irons. Horizontal pull-out test Force range: (1-8) kN PN-EN 1917:2004 Załącznik E","search_zh":"素混凝土、钢纤维混凝土与钢筋混凝土的可进入式与不可进入式检查井 PN-EN 1917:2004 Załącznik E","test_object_zh":"素混凝土、钢纤维混凝土与钢筋混凝土的可进入式与不可进入式检查井"},{"_id":"6a5a55ec9af9f73f38250060","lab_id":"69ad52a3de79e566650fb5a0","country":"PL","accr_number":"AB 1106","accr_body":"PCA","test_object":"Rury i kształtki z betonu, betonu niezbrojonego, betonu zbrojonego włóknem stalowym i żelbetowym","test_object_en":"Pipes and fittings of concrete, unreinforced concrete, steel fibre reinforced concrete and reinforced concrete","methodology":"Nasiąkliwość wodą","methodology_en":"Water absorption","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nasiąkliwość wodą","reference":"PN-EN 1916: 2005 PN-EN 1916: 2005/AC:2009 Załącznik F","norm_bases":["PN-EN 1916: 2005 PN-EN 1916: 2005/AC:2009 Załącznik F"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury i kształtki z betonu, betonu niezbrojonego, betonu zbrojonego włóknem stalowym i żelbetowym Nasiąkliwość wodą PN-EN 1916: 2005 PN-EN 1916: 2005/AC:2009 Załącznik F Rury i ksztaltki z betonu, betonu niezbrojonego, betonu zbrojonego wloknem stalowym i zelbetowym Nasiakliwosc woda PN-EN 1916: 2005 PN-EN 1916: 2005/AC:2009 Zalacznik F","categories":["construction","materials"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Pipes and fittings of concrete, unreinforced concrete, steel fibre reinforced concrete and reinforced concrete Water absorption PN-EN 1916: 2005 PN-EN 1916: 2005/AC:2009 Załącznik F"},{"_id":"6a5a55ec9af9f73f38250061","lab_id":"69ad52a3de79e566650fb5a0","country":"PL","accr_number":"AB 1106","accr_body":"PCA","test_object":"Rury z tworzyw termoplastycznych","test_object_en":"Thermoplastic pipes","methodology":"Sztywność obwodowa Zakres:(0,1 – 150) kN","methodology_en":"Ring stiffness Range:(0,1 – 150) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sztywność obwodowa Zakres:(0,1 – 150) kN","reference":"PN-EN ISO 9969:2016-02","norm_bases":["PN-EN ISO 9969:2016-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury z tworzyw termoplastycznych Sztywność obwodowa Zakres:(0,1 – 150) kN PN-EN ISO 9969:2016-02 Rury z tworzyw termoplastycznych Sztywnosc obwodowa Zakres:(0,1 – 150) kN PN-EN ISO 9969:2016-02","categories":["other"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermoplastic pipes Ring stiffness Range:(0,1 – 150) kN PN-EN ISO 9969:2016-02","search_zh":"热塑性塑料管材 PN-EN ISO 9969:2016-02","test_object_zh":"热塑性塑料管材"},{"_id":"6a5a55ec9af9f73f38250062","lab_id":"69ad52a3de79e566650fb5a0","country":"PL","accr_number":"AB 1106","accr_body":"PCA","test_object":"Beton","test_object_en":"Concrete","methodology":"Wytrzymałość na ściskanie Zakres siły: (300 – 3000) kN","methodology_en":"Compressive strength Force range: (300 – 3000) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie Zakres siły: (300 – 3000) kN","reference":"PN-EN 12390-3:2011 PN-EN 12390-3:2011/AC:2012 PN-EN 12390-3:2019-07","norm_bases":["PN-EN 12390-3:2011 PN-EN 12390-3:2011/AC:2012 PN-EN 12390-3:2019-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton Wytrzymałość na ściskanie Zakres siły: (300 – 3000) kN PN-EN 12390-3:2011 PN-EN 12390-3:2011/AC:2012 PN-EN 12390-3:2019-07 Beton Wytrzymalosc na sciskanie Zakres sily: (300 – 3000) kN PN-EN 12390-3:2011 PN-EN 12390-3:2011/AC:2012 PN-EN 12390-3:2019-07","categories":["construction"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete Compressive strength Force range: (300 – 3000) kN PN-EN 12390-3:2011 PN-EN 12390-3:2011/AC:2012 PN-EN 12390-3:2019-07","search_zh":"混凝土 PN-EN 12390-3:2011 PN-EN 12390-3:2011/AC:2012 PN-EN 12390-3:2019-07","test_object_zh":"混凝土"},{"_id":"6a5a55ec9af9f73f38250063","lab_id":"69ad52a3de79e566650fb5a0","country":"PL","accr_number":"AB 1106","accr_body":"PCA","test_object":"Beton","test_object_en":"Concrete","methodology":"Odporność na działanie mrozu","methodology_en":"Resistance to freezing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie mrozu","reference":"PN-B-06265:2022-06 Załącznik N","norm_bases":["PN-B-06265:2022-06 Załącznik N"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton Odporność na działanie mrozu PN-B-06265:2022-06 Załącznik N Beton Odpornosc na dzialanie mrozu PN-B-06265:2022-06 Zalacznik N","categories":["construction"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete Resistance to freezing PN-B-06265:2022-06 Załącznik N","methodology_zh":"抗冻性","search_zh":"混凝土 抗冻性 PN-B-06265:2022-06 Załącznik N","test_object_zh":"混凝土"}],"has_pdf":true}