{"lab":{"_id":"69ad52a3de79e566650fb590","accr_number":"AB 1095","country":"PL","accr_body":"PCA","address":"ul. Mochtyńska 65, 03-289 Warszawa","categories":["water","environment","food","microbiology","materials","pharma","petro","construction"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":470,"name":"GBA POLSKA Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1095.pdf"],"scope_summary":"","search_text":"gba polska sp. z o.o. ul. mochtyńska 65, 03-289 warszawa food other pharma water materials petro environment construction electronics metrology microbiology automotive","status":"active","updated_at":"2026-03-08T14:50:16.733Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T08:31:59.150Z","email_confidence":"high","email_mx":true,"email_source":"https://www.gba-polska.pl/kontakt/","parse_date":"2026-08-17T08:31:59.150Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"C/1; C/4; C/5; C/10; C/17; C/18; C/20, C/21, C/22; C/28; C/29; C/30; C/31; C/32; C/36; C/42; C/43; C/44; C/49; C/55","pl":"Badania chemiczne produktów rolnych, wyrobów chemicznych, materiałów budowlanych, paliw, wyrobów innych – wyrobów medycznych, papieru, tektury , wyrobów farmaceutycznych, wyrobów z tworzyw sztucznych i gumy, żywności, wody, wody do spożycia przez ludzi, ścieków, gleby, gruntów, osadów, odpadów, gazów składowiskowych, kosmetyków, nawozów, środków wspomagających uprawę roślin, materiałów opakowaniowych, pasz dla zwierząt","en":"Chemical tests of agricultural products, chemical products, building materials, fuels, other products – medical products, paper, cardboard, pharmaceutical products, plastic and rubber products, food, water, drinking water, sewage, soil, ground, sediments, waste, landfill gases, cosmetics, fertilizers, plant growth substances, packaging materials, animal feedstuffs"},{"codes":"K/4; K/9; K/17; K/20; K/22, K/28; K/29; K/30; K/31; K/32; K/42; K/43; K/44; K/49; K/55; K/57","pl":"Badania mikrobiologiczne, wyrobów chemicznych, powietrza, wyrobów innych – obiektów z obszarów niezwiązanych z produkcją żywności, płynów, koncentratów oraz wody do dializ, wody ultraczystej, wyrobów farmaceutycznych, żywności, wody, wody do spożycia przez ludzi, ścieków, gleb, osadów, odpadów, kosmetyków, nawozów, środków wspomagających uprawę roślin, materiałów opakowaniowych, pasz dla zwierząt, obiektów z obszaru produkcji żywności","en":"Microbiological tests of chemical product, air, other products - objects from non-food related areas, liquids, concentrates and dialysis water, ultrapure water, pharmaceutical products, food, water, drinking water, sewage, soil, sediments, waste, cosmetics, fertilizers, plant growth substances, packaging materials, animal feedstuffs, objects from food production area."},{"codes":"N/1; N/4; N/9; N/10; N/17; N/21; N/22; N/28, N/29, N/30, N/31, N32, N/36, N/42, N43, N/44, N/49, N/55","pl":"Badania właściwości fizycznych produktów rolnych, wyrobów chemicznych, powierza, paliw, wyrobów innych – wyrobów medycznych, wyrobów z tworzyw sztucznych i gumy, żywności, wody, wody do spożycia przez ludzi, ścieków, gleby, gruntów, osadów, odpadów, gazów składowiskowych, kosmetyków, nawozów, środków wspomagających uprawę roślin, materiałów opakowaniowych, pasz dla zwierząt","en":"Tests of physical properties of agricultural products, chemical product, air, fuels, other products - medical products, plastic and rubber products, food, water, drinking water, sewage, soil, ground, sediments, waste, landfill gases, cosmetics, fertilizers, plant growth substances, packaging materials, animal feedstuffs,."}],"issue":{"no":"25","date":"03.07.2026"},"flexible_scope":true,"format_family":"legend-letter","lab_locations":[{"name":"Laboratorium Fizykochemiczne Badań Żywności","address":"Łajski, ul. Kościelna 2a, 05-119 Legionowo","city":"Legionowo","postal":"05-119"},{"name":"Laboratorium Mikrobiologiczne","address":"Łajski, ul. Kościelna 2a, 05-119 Legionowo","city":"Legionowo","postal":"05-119"},{"name":"Dział Próbkobrania","address":"Łajski, ul. Kościelna 2a, 05-119 Legionowo","city":"Legionowo","postal":"05-119"},{"name":"Laboratorium Fizykochemiczne","address":"ul. Fabryczna 7, 41-404 Mysłowice","city":"Mysłowice","postal":"41-404"},{"name":"Laboratorium Kosmetyczne","address":"ul. Ząbkowska 18, 03-735 Warszawa","city":"Warszawa","postal":"03-735"}],"locations_extracted_at":"2026-07-24T05:06:31.447Z","map_coord":[52.352769,21.038299],"map_geo":"nominatim-street","scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/935d87b7bca31b62fb9fb29020706ed6/AB%201095.pdf","has_en":true,"category_counts":{"water":197,"environment":135,"food":127,"microbiology":88,"other":75,"materials":30,"pharma":28,"petro":24,"construction":22,"metrology":1},"category_scores":{"water":53.38,"environment":25.07,"food":22.19,"microbiology":10.65,"other":7.74,"materials":1.24,"pharma":1.08,"petro":0.79,"construction":0.67,"metrology":0},"has_zh":true,"lab_locations_zh":[{"name":"Laboratorium Fizykochemiczne Badań Żywności","address":"Łajski, ul. Kościelna 2a, 05-119 Legionowo","city":"Legionowo","postal":"05-119"},{"name":"微生物实验室","address":"Łajski, ul. Kościelna 2a, 05-119 Legionowo","city":"Legionowo","postal":"05-119"},{"name":"Dział Próbkobrania","address":"Łajski, ul. Kościelna 2a, 05-119 Legionowo","city":"Legionowo","postal":"05-119"},{"name":"Laboratorium Fizykochemiczne","address":"ul. Fabryczna 7, 41-404 Mysłowice","city":"Mysłowice","postal":"41-404"},{"name":"Laboratorium Kosmetyczne","address":"ul. Ząbkowska 18, 03-735 Warszawa","city":"Warszawa","postal":"03-735"}]},"methods":[{"_id":"6a82c6ff884ede9a1b2c294c","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Przedmiot badań/wyrób","methodology":"Rodzaj działalności/badane cechy/metoda","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Rodzaj działalności/badane cechy/metoda","reference":"Dokumenty odniesienia","norm_bases":["Dokumenty odniesienia"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przedmiot badań/wyrób Rodzaj działalności/badane cechy/metoda Dokumenty odniesienia Przedmiot badan/wyrob Rodzaj dzialalnosci/badane cechy/metoda Dokumenty odniesienia","categories":["other"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Type of activity/characteristics tested/method","search_en":"Test object/product Type of activity/characteristics tested/method Dokumenty odniesienia","test_object_en":"Test object/product","search_zh":"检测对象/产品 活动类别/受检特性/方法 Dokumenty odniesienia","test_object_zh":"检测对象/产品","methodology_zh":"活动类别/受检特性/方法"},{"_id":"6a82c6ff884ede9a1b2c294d","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Mięso i przetwory mięsne, Ryby i przetwory rybne, Wyroby garmażeryjne, Pasze","methodology":"Zawartość skrobi","parameters":[{"name":"Zakres","range":"(0,2-80)%"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość skrobi\nZakres (0,2-80)%\nMetoda spektrofotometryczna","reference":"PB-320 wyd. 1 z dnia 14.06.2024 Ł","norm_bases":["PB-320 wyd. 1 z dnia 14.06.2024 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne, Ryby i przetwory rybne, Wyroby garmażeryjne, Pasze Zawartość skrobi\nZakres (0,2-80)%\nMetoda spektrofotometryczna PB-320 wyd. 1 z dnia 14.06.2024 Ł Mieso i przetwory miesne, Ryby i przetwory rybne, Wyroby garmazeryjne, Pasze Zawartosc skrobi\nZakres (0,2-80)%\nMetoda spektrofotometryczna PB-320 wyd. 1 z dnia 14.06.2024 L","categories":["food"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Starch content","parameters_en":[{"name":"Range","range":"(0,2-80)%"}],"search_en":"Meat and meat products, Fish and fish products, Delicatessen products, Feed Starch content Spectrophotometric method Range PB-320 wyd. 1 z dnia 14.06.2024 Ł","technique_en":"Spectrophotometric method","test_object_en":"Meat and meat products, Fish and fish products, Delicatessen products, Feed","parameters_zh":[{"name":"范围","range":"(0,2-80)%"}],"search_zh":"淀粉含量 分光光度法 范围 PB-320 wyd. 1 z dnia 14.06.2024 Ł","technique_zh":"分光光度法","methodology_zh":"淀粉含量"},{"_id":"6a82c6ff884ede9a1b2c294e","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość hydroksyproliny","parameters":[{"name":"Zakres","range":"(0,01 – 1,4)%"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość hydroksyproliny\nZakres (0,01 – 1,4)%\nMetoda spektrofotometryczna","reference":"PN-ISO 3496:2000 Ł","norm_bases":["PN-ISO 3496:2000 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość hydroksyproliny\nZakres (0,01 – 1,4)%\nMetoda spektrofotometryczna PN-ISO 3496:2000 Ł Mieso i przetwory miesne Zawartosc hydroksyproliny\nZakres (0,01 – 1,4)%\nMetoda spektrofotometryczna PN-ISO 3496:2000 L","categories":["food"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydroxyproline content","parameters_en":[{"name":"Range","range":"(0,01 – 1,4)%"}],"search_en":"Meat and meat products Hydroxyproline content Spectrophotometric method Range PN-ISO 3496:2000 Ł","technique_en":"Spectrophotometric method","test_object_en":"Meat and meat products","parameters_zh":[{"name":"范围","range":"(0,01 – 1,4)%"}],"search_zh":"肉与肉制品 羟脯氨酸含量 分光光度法 范围 PN-ISO 3496:2000 Ł","technique_zh":"分光光度法","test_object_zh":"肉与肉制品","methodology_zh":"羟脯氨酸含量"},{"_id":"6a82c6ff884ede9a1b2c294f","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość kolagenu, Z obliczeń, Zawartość tkanki łącznej, Z obliczeń","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość kolagenu, Z obliczeń, Zawartość tkanki łącznej, Z obliczeń","reference":"Rozporządzenie PEiR (UE) Nr 1169/2011 z dnia 25 października 2011 r. Załącznik VI część B, Załącznik VII część B (ze zm.) Ł","norm_bases":["Rozporządzenie PEiR (UE) Nr 1169/2011 z dnia 25 października 2011 r. Załącznik VI część B, Załącznik VII część B (ze zm.) Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość kolagenu, Z obliczeń, Zawartość tkanki łącznej, Z obliczeń Rozporządzenie PEiR (UE) Nr 1169/2011 z dnia 25 października 2011 r. Załącznik VI część B, Załącznik VII część B (ze zm.) Ł Mieso i przetwory miesne Zawartosc kolagenu, Z obliczen, Zawartosc tkanki lacznej, Z obliczen Rozporzadzenie PEiR (UE) Nr 1169/2011 z dnia 25 pazdziernika 2011 r. Zalacznik VI czesc B, Zalacznik VII czesc B (ze zm.) L","categories":["food"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Collagen content, Calculated, Connective tissue content, Calculated","search_en":"Meat and meat products Collagen content, Calculated, Connective tissue content, Calculated Rozporządzenie PEiR (UE) Nr 1169/2011 z dnia 25 października 2011 r. Załącznik VI część B, Załącznik VII część B (ze zm.) Ł","test_object_en":"Meat and meat products","search_zh":"肉与肉制品 Rozporządzenie PEiR (UE) Nr 1169/2011 z dnia 25 października 2011 r. Załącznik VI część B, Załącznik VII część B (ze zm.) Ł","test_object_zh":"肉与肉制品"},{"_id":"6a82c6ff884ede9a1b2c2950","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Mięso i przetwory mięsne, Mleko i przetwory mleczne, Koncentraty spożywcze, Ryby i przetwory rybne, Wyroby cukiernicze, Zboża i przetwory zbożowe, Wyroby garmażeryjne, Zioła i przetwory zielarskie, Suplementy diety","methodology":"Zawartość skrobi","parameters":[{"name":"Zakres","range":"(0,50 – 80)%"}],"technique":"Metoda miareczkowa (Luffa-Schoorla)","techniques":["Metoda miareczkowa (Luffa-Schoorla)"],"computed":[],"activity":"Zawartość skrobi\nZakres (0,50 – 80)%\nMetoda miareczkowa (Luffa-Schoorla)","reference":"PB-54/LF wyd. 3 z dnia 03.01.2022 Ł","norm_bases":["PB-54/LF wyd. 3 z dnia 03.01.2022 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne, Mleko i przetwory mleczne, Koncentraty spożywcze, Ryby i przetwory rybne, Wyroby cukiernicze, Zboża i przetwory zbożowe, Wyroby garmażeryjne, Zioła i przetwory zielarskie, Suplementy diety Zawartość skrobi\nZakres (0,50 – 80)%\nMetoda miareczkowa (Luffa-Schoorla) PB-54/LF wyd. 3 z dnia 03.01.2022 Ł Mieso i przetwory miesne, Mleko i przetwory mleczne, Koncentraty spozywcze, Ryby i przetwory rybne, Wyroby cukiernicze, Zboza i przetwory zbozowe, Wyroby garmazeryjne, Ziola i przetwory zielarskie, Suplementy diety Zawartosc skrobi\nZakres (0,50 – 80)%\nMetoda miareczkowa (Luffa-Schoorla) PB-54/LF wyd. 3 z dnia 03.01.2022 L","categories":["food","pharma"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Starch content","parameters_en":[{"name":"Range","range":"(0,50 – 80)%"}],"search_en":"Meat and meat products, Milk and dairy products, Food concentrates, Fish and fish products, Confectionery products, Cereals and cereal products, Delicatessen products, Herbs and herbal products, Food supplements Starch content Titrimetric method (Luff-Schoorl) Range PB-54/LF wyd. 3 z dnia 03.01.2022 Ł","technique_en":"Titrimetric method (Luff-Schoorl)","test_object_en":"Meat and meat products, Milk and dairy products, Food concentrates, Fish and fish products, Confectionery products, Cereals and cereal products, Delicatessen products, Herbs and herbal products, Food supplements","parameters_zh":[{"name":"范围","range":"(0,50 – 80)%"}],"search_zh":"淀粉含量 滴定法（Luff-Schoorl 法） 范围 PB-54/LF wyd. 3 z dnia 03.01.2022 Ł","methodology_zh":"淀粉含量","technique_zh":"滴定法（Luff-Schoorl 法）"},{"_id":"6a82c6ff884ede9a1b2c2951","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Pasze","methodology":"Zawartość skrobi","parameters":[{"name":"Zakres","range":"(0,50 - 80)%"}],"technique":"Metoda miareczkowa (Luffa-Schoorla)","techniques":["Metoda miareczkowa (Luffa-Schoorla)"],"computed":[],"activity":"Zawartość skrobi\nZakres (0,50 - 80)%\nMetoda miareczkowa (Luffa-Schoorla)","reference":"Ł","norm_bases":["Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze Zawartość skrobi\nZakres (0,50 - 80)%\nMetoda miareczkowa (Luffa-Schoorla) Ł Pasze Zawartosc skrobi\nZakres (0,50 - 80)%\nMetoda miareczkowa (Luffa-Schoorla) L","categories":["food"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Starch content","parameters_en":[{"name":"Range","range":"(0,50 - 80)%"}],"search_en":"Feed Starch content Titrimetric method (Luff-Schoorl) Range Ł","technique_en":"Titrimetric method (Luff-Schoorl)","test_object_en":"Feed","parameters_zh":[{"name":"范围","range":"(0,50 - 80)%"}],"search_zh":"饲料 淀粉含量 滴定法（Luff-Schoorl 法） 范围 Ł","test_object_zh":"饲料","methodology_zh":"淀粉含量","technique_zh":"滴定法（Luff-Schoorl 法）"},{"_id":"6a82c6ff884ede9a1b2c2952","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Kawa, Herbata, Koncentraty spożywcze, Mięso i przetwory mięsne, Mleko i przetwory mleczne, Napoje bezalkoholowe, Napoje alkoholowe, Owoce i warzywa, Przetwory owocowe i warzywne, Ryby i przetwory rybne, Wyroby cukiernicze, Zioła i przetwory zielarskie, Przyprawy, Zboża i przetwory zbożowe, Suplementy diety, Środki spożywcze specjalnego przeznaczenia medycznego, Oleje, tłuszcze zwierzęce i roślinne, Jaja i przetwory jajeczne, Dodatki do żywności, Wyroby garmażeryjne, Pasze, Kosmetyki, Chemia gospodarcza","methodology":"Aktywność wody","parameters":[{"name":"Zakres","range":"(0,050 – 0,989)"}],"technique":"Metoda wykrywania punktu rosy","techniques":["Metoda wykrywania punktu rosy"],"computed":[],"activity":"Aktywność wody\nZakres (0,050 – 0,989)\nMetoda wykrywania punktu rosy","reference":"PB-87/LF wyd. 3 z dnia 03.01.2022 Ł","norm_bases":["PB-87/LF wyd. 3 z dnia 03.01.2022 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kawa, Herbata, Koncentraty spożywcze, Mięso i przetwory mięsne, Mleko i przetwory mleczne, Napoje bezalkoholowe, Napoje alkoholowe, Owoce i warzywa, Przetwory owocowe i warzywne, Ryby i przetwory rybne, Wyroby cukiernicze, Zioła i przetwory zielarskie, Przyprawy, Zboża i przetwory zbożowe, Suplementy diety, Środki spożywcze specjalnego przeznaczenia medycznego, Oleje, tłuszcze zwierzęce i roślinne, Jaja i przetwory jajeczne, Dodatki do żywności, Wyroby garmażeryjne, Pasze, Kosmetyki, Chemia gospodarcza Aktywność wody\nZakres (0,050 – 0,989)\nMetoda wykrywania punktu rosy PB-87/LF wyd. 3 z dnia 03.01.2022 Ł Kawa, Herbata, Koncentraty spozywcze, Mieso i przetwory miesne, Mleko i przetwory mleczne, Napoje bezalkoholowe, Napoje alkoholowe, Owoce i warzywa, Przetwory owocowe i warzywne, Ryby i przetwory rybne, Wyroby cukiernicze, Ziola i przetwory zielarskie, Przyprawy, Zboza i przetwory zbozowe, Suplementy diety, Srodki spozywcze specjalnego przeznaczenia medycznego, Oleje, tluszcze zwierzece i roslinne, Jaja i przetwory jajeczne, Dodatki do zywnosci, Wyroby garmazeryjne, Pasze, Kosmetyki, Chemia gospodarcza Aktywnosc wody\nZakres (0,050 – 0,989)\nMetoda wykrywania punktu rosy PB-87/LF wyd. 3 z dnia 03.01.2022 L","categories":["food","pharma","water","petro"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water activity","parameters_en":[{"name":"Range","range":"(0,050 – 0,989)"}],"search_en":"Coffee, Tea, Food concentrates, Meat and meat products, Milk and dairy products, Non-alcoholic beverages, Alcoholic beverages, Fruit and vegetables, Fruit and vegetable products, Fish and fish products, Confectionery, Herbs and herbal products, Spices, Cereals and cereal products, Dietary supplements, Foodstuffs for special medical purposes, Oils, animal and vegetable fats, Eggs and egg products, Food additives, Delicatessen products, Feed, Cosmetics, Household chemicals Water activity Dew point detection method Range PB-87/LF wyd. 3 z dnia 03.01.2022 Ł","technique_en":"Dew point detection method","test_object_en":"Coffee, Tea, Food concentrates, Meat and meat products, Milk and dairy products, Non-alcoholic beverages, Alcoholic beverages, Fruit and vegetables, Fruit and vegetable products, Fish and fish products, Confectionery, Herbs and herbal products, Spices, Cereals and cereal products, Dietary supplements, Foodstuffs for special medical purposes, Oils, animal and vegetable fats, Eggs and egg products, Food additives, Delicatessen products, Feed, Cosmetics, Household chemicals","methodology_zh":"水分活度","parameters_zh":[{"name":"范围","range":"(0,050 – 0,989)"}],"search_zh":"水分活度 露点检测法 范围 PB-87/LF wyd. 3 z dnia 03.01.2022 Ł","technique_zh":"露点检测法"},{"_id":"6a82c6ff884ede9a1b2c2953","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Oleje, tłuszcze zwierzęce i roślinne","methodology":"Liczba kwasowa","parameters":[{"name":"Zakres","range":"(0,10 - 90) mg KOH/g"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba kwasowa\nZakres (0,10 - 90) mg KOH/g\nMetoda miareczkowa","reference":"PN-EN ISO 660:2021-03 Ł","norm_bases":["PN-EN ISO 660:2021-03 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oleje, tłuszcze zwierzęce i roślinne Liczba kwasowa\nZakres (0,10 - 90) mg KOH/g\nMetoda miareczkowa PN-EN ISO 660:2021-03 Ł Oleje, tluszcze zwierzece i roslinne Liczba kwasowa\nZakres (0,10 - 90) mg KOH/g\nMetoda miareczkowa PN-EN ISO 660:2021-03 L","categories":["food","petro"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acid value","parameters_en":[{"name":"Range","range":"(0,10 - 90) mg KOH/g"}],"search_en":"Oils, animal and vegetable fats Acid value Titrimetric method Range PN-EN ISO 660:2021-03 Ł","technique_en":"Titrimetric method","test_object_en":"Oils, animal and vegetable fats","parameters_zh":[{"name":"范围","range":"(0,10 - 90) mg KOH/g"}],"search_zh":"食用油、动植物油脂 酸值 滴定法 范围 PN-EN ISO 660:2021-03 Ł","technique_zh":"滴定法","methodology_zh":"酸值","test_object_zh":"食用油、动植物油脂"},{"_id":"6a82c6ff884ede9a1b2c2954","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Oleje, tłuszcze zwierzęce i roślinne","methodology":"Kwasowość (wolne kwasy tłuszczowe)","parameters":[{"name":"Zakres","range":"(0,05 - 45) %"},{"name":"Z obliczeń"}],"technique":null,"techniques":[],"computed":[],"activity":"Kwasowość (wolne kwasy tłuszczowe)\nZakres:\nZakres (0,05 - 45) %\nZ obliczeń","reference":"Ł","norm_bases":["Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oleje, tłuszcze zwierzęce i roślinne Kwasowość (wolne kwasy tłuszczowe)\nZakres:\nZakres (0,05 - 45) %\nZ obliczeń Ł Oleje, tluszcze zwierzece i roslinne Kwasowosc (wolne kwasy tluszczowe)\nZakres:\nZakres (0,05 - 45) %\nZ obliczen L","categories":["food","petro"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acidity (free fatty acids)","parameters_en":[{"name":"Range","range":"(0,05 - 45) %"},{"name":"Calculated"}],"search_en":"Oils, animal and vegetable fats Acidity (free fatty acids) Range Calculated Ł","test_object_en":"Oils, animal and vegetable fats","parameters_zh":[{"name":"范围","range":"(0,05 - 45) %"},{"name":"由计算得出"}],"search_zh":"食用油、动植物油脂 范围 由计算得出 Ł","test_object_zh":"食用油、动植物油脂"},{"_id":"6a82c6ff884ede9a1b2c2955","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Oleje, tłuszcze zwierzęce i roślinne","methodology":"Liczba anizydynowa","parameters":[{"name":"Zakres","range":"(0,5 - 70)"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Liczba anizydynowa\nZakres (0,5 - 70)\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6885:2016-04 Ł","norm_bases":["PN-EN ISO 6885:2016-04 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oleje, tłuszcze zwierzęce i roślinne Liczba anizydynowa\nZakres (0,5 - 70)\nMetoda spektrofotometryczna PN-EN ISO 6885:2016-04 Ł Oleje, tluszcze zwierzece i roslinne Liczba anizydynowa\nZakres (0,5 - 70)\nMetoda spektrofotometryczna PN-EN ISO 6885:2016-04 L","categories":["food","petro"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anisidine value","parameters_en":[{"name":"Range","range":"(0,5 - 70)"}],"search_en":"Oils, animal and vegetable fats Anisidine value Spectrophotometric method Range PN-EN ISO 6885:2016-04 Ł","technique_en":"Spectrophotometric method","test_object_en":"Oils, animal and vegetable fats","parameters_zh":[{"name":"范围","range":"(0,5 - 70)"}],"search_zh":"食用油、动植物油脂 茴香胺值 分光光度法 范围 PN-EN ISO 6885:2016-04 Ł","technique_zh":"分光光度法","methodology_zh":"茴香胺值","test_object_zh":"食用油、动植物油脂"},{"_id":"6a82c6ff884ede9a1b2c2956","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Koncentraty spożywcze","methodology":"Kwasowość ogólna","parameters":[{"name":"Zakres","range":"(0,20-50) °N"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość ogólna\nZakres (0,20-50) °N\nMetoda miareczkowa","reference":"PN-A-79011-9:1998 Ł","norm_bases":["PN-A-79011-9:1998 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Koncentraty spożywcze Kwasowość ogólna\nZakres (0,20-50) °N\nMetoda miareczkowa PN-A-79011-9:1998 Ł Koncentraty spozywcze Kwasowosc ogolna\nZakres (0,20-50) °N\nMetoda miareczkowa PN-A-79011-9:1998 L","categories":["other"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total acidity","parameters_en":[{"name":"Range","range":"(0,20-50) °N"}],"search_en":"Food concentrates Total acidity Titrimetric method Range PN-A-79011-9:1998 Ł","technique_en":"Titrimetric method","test_object_en":"Food concentrates","parameters_zh":[{"name":"范围","range":"(0,20-50) °N"}],"search_zh":"食品浓缩制品 总酸度 滴定法 范围 PN-A-79011-9:1998 Ł","technique_zh":"滴定法","test_object_zh":"食品浓缩制品","methodology_zh":"总酸度"},{"_id":"6a82c6ff884ede9a1b2c2957","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Koncentraty spożywcze, Ryby i przetwory rybne, Mięso i produkty mięsne, Wyroby cukiernicze i ciastkarskie, Zboża i przetwory zbożowe, Wyroby garmażeryjne, Dodatki do żywności, Suplementy diety, Porcje żywnościowe, Oleje oraz tłuszcze roślinne i zwierzęce, Przetwory owocowo-warzywne, Sosy, Majonez, Nasiona oleiste, Pasze","methodology":"Liczba nadtlenkowa i liczba nadtlenkowa wyekstrahowanego tłuszczu","parameters":[{"name":"Zakres","range":"(0,10 – 30,0) meq O2/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba nadtlenkowa i liczba nadtlenkowa wyekstrahowanego tłuszczu\nZakres (0,10 – 30,0) meq O2/kg\nMetoda miareczkowa","reference":"PB-72/LF wyd. 7 z dnia 11.12.2024 Ł","norm_bases":["PB-72/LF wyd. 7 z dnia 11.12.2024 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Koncentraty spożywcze, Ryby i przetwory rybne, Mięso i produkty mięsne, Wyroby cukiernicze i ciastkarskie, Zboża i przetwory zbożowe, Wyroby garmażeryjne, Dodatki do żywności, Suplementy diety, Porcje żywnościowe, Oleje oraz tłuszcze roślinne i zwierzęce, Przetwory owocowo-warzywne, Sosy, Majonez, Nasiona oleiste, Pasze Liczba nadtlenkowa i liczba nadtlenkowa wyekstrahowanego tłuszczu\nZakres (0,10 – 30,0) meq O2/kg\nMetoda miareczkowa PB-72/LF wyd. 7 z dnia 11.12.2024 Ł Koncentraty spozywcze, Ryby i przetwory rybne, Mieso i produkty miesne, Wyroby cukiernicze i ciastkarskie, Zboza i przetwory zbozowe, Wyroby garmazeryjne, Dodatki do zywnosci, Suplementy diety, Porcje zywnosciowe, Oleje oraz tluszcze roslinne i zwierzece, Przetwory owocowo-warzywne, Sosy, Majonez, Nasiona oleiste, Pasze Liczba nadtlenkowa i liczba nadtlenkowa wyekstrahowanego tluszczu\nZakres (0,10 – 30,0) meq O2/kg\nMetoda miareczkowa PB-72/LF wyd. 7 z dnia 11.12.2024 L","categories":["food","petro","pharma"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Peroxide value and peroxide value of extracted fat","parameters_en":[{"name":"Range","range":"(0,10 – 30,0) meq O2/kg"}],"search_en":"Food concentrates, Fish and fish products, Meat and meat products, Confectionery and bakery products, Cereals and cereal products, Delicatessen products, Food additives, Food supplements, Food rations, Vegetable and animal oils and fats, Fruit and vegetable preserves, Sauces, Mayonnaise, Oilseeds, Feed Peroxide value and peroxide value of extracted fat Titrimetric method Range PB-72/LF wyd. 7 z dnia 11.12.2024 Ł","technique_en":"Titrimetric method","test_object_en":"Food concentrates, Fish and fish products, Meat and meat products, Confectionery and bakery products, Cereals and cereal products, Delicatessen products, Food additives, Food supplements, Food rations, Vegetable and animal oils and fats, Fruit and vegetable preserves, Sauces, Mayonnaise, Oilseeds, Feed","parameters_zh":[{"name":"范围","range":"(0,10 – 30,0) meq O2/kg"}],"search_zh":"食品浓缩制品，鱼与鱼制品，肉与肉制品，糖果与糕点制品，谷物与谷物制品，熟食制品，食品添加剂，膳食补充剂 滴定法 范围 PB-72/LF wyd. 7 z dnia 11.12.2024 Ł","technique_zh":"滴定法","test_object_zh":"食品浓缩制品，鱼与鱼制品，肉与肉制品，糖果与糕点制品，谷物与谷物制品，熟食制品，食品添加剂，膳食补充剂"},{"_id":"6a82c6ff884ede9a1b2c2958","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Koncentraty spożywcze, Ryby i przetwory rybne, Mięso i produkty mięsne, Wyroby cukiernicze i ciastkarskie, Zboża i przetwory zbożowe, Wyroby garmażeryjne, Dodatki do żywności, Suplementy diety, Porcje żywnościowe, Oleje oraz tłuszcze roślinne i zwierzęce, Przetwory owocowo-warzywne, Sosy, Majonez, Nasiona oleiste, Pasze","methodology":"Liczba kwasowa i liczba kwasowa wyekstrahowanego tłuszczu","parameters":[{"name":"Zakres","range":"(0,10 - 90) mg KOH/g"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba kwasowa i liczba kwasowa wyekstrahowanego tłuszczu\nZakres (0,10 - 90) mg KOH/g\nMetoda miareczkowa","reference":"PB-20/LF wyd. 8 z dnia 14.06.2024 Ł","norm_bases":["PB-20/LF wyd. 8 z dnia 14.06.2024 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Koncentraty spożywcze, Ryby i przetwory rybne, Mięso i produkty mięsne, Wyroby cukiernicze i ciastkarskie, Zboża i przetwory zbożowe, Wyroby garmażeryjne, Dodatki do żywności, Suplementy diety, Porcje żywnościowe, Oleje oraz tłuszcze roślinne i zwierzęce, Przetwory owocowo-warzywne, Sosy, Majonez, Nasiona oleiste, Pasze Liczba kwasowa i liczba kwasowa wyekstrahowanego tłuszczu\nZakres (0,10 - 90) mg KOH/g\nMetoda miareczkowa PB-20/LF wyd. 8 z dnia 14.06.2024 Ł Koncentraty spozywcze, Ryby i przetwory rybne, Mieso i produkty miesne, Wyroby cukiernicze i ciastkarskie, Zboza i przetwory zbozowe, Wyroby garmazeryjne, Dodatki do zywnosci, Suplementy diety, Porcje zywnosciowe, Oleje oraz tluszcze roslinne i zwierzece, Przetwory owocowo-warzywne, Sosy, Majonez, Nasiona oleiste, Pasze Liczba kwasowa i liczba kwasowa wyekstrahowanego tluszczu\nZakres (0,10 - 90) mg KOH/g\nMetoda miareczkowa PB-20/LF wyd. 8 z dnia 14.06.2024 L","categories":["food","petro","pharma"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acid value and acid value of extracted fat","parameters_en":[{"name":"Range","range":"(0,10 - 90) mg KOH/g"}],"search_en":"Food concentrates, Fish and fish products, Meat and meat products, Confectionery and bakery products, Cereals and cereal products, Delicatessen products, Food additives, Food supplements, Food rations, Vegetable and animal oils and fats, Fruit and vegetable preserves, Sauces, Mayonnaise, Oilseeds, Feed Acid value and acid value of extracted fat Titrimetric method Range PB-20/LF wyd. 8 z dnia 14.06.2024 Ł","technique_en":"Titrimetric method","test_object_en":"Food concentrates, Fish and fish products, Meat and meat products, Confectionery and bakery products, Cereals and cereal products, Delicatessen products, Food additives, Food supplements, Food rations, Vegetable and animal oils and fats, Fruit and vegetable preserves, Sauces, Mayonnaise, Oilseeds, Feed","parameters_zh":[{"name":"范围","range":"(0,10 - 90) mg KOH/g"}],"search_zh":"食品浓缩制品，鱼与鱼制品，肉与肉制品，糖果与糕点制品，谷物与谷物制品，熟食制品，食品添加剂，膳食补充剂 滴定法 范围 PB-20/LF wyd. 8 z dnia 14.06.2024 Ł","technique_zh":"滴定法","test_object_zh":"食品浓缩制品，鱼与鱼制品，肉与肉制品，糖果与糕点制品，谷物与谷物制品，熟食制品，食品添加剂，膳食补充剂"},{"_id":"6a82c6ff884ede9a1b2c2959","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Koncentraty spożywcze, Ryby i przetwory rybne, Mięso i produkty mięsne, Wyroby cukiernicze i ciastkarskie, Zboża i przetwory zbożowe, Wyroby garmażeryjne, Dodatki do żywności, Suplementy diety, Porcje żywnościowe, Oleje oraz tłuszcze roślinne i zwierzęce, Przetwory owocowo-warzywne, Sosy, Majonez, Nasiona oleiste, Pasze","methodology":"Kwasowość (wolne kwasy tłuszczowe)","parameters":[{"name":"Zakres","range":"(0,05 - 45) %"},{"name":"Z obliczeń"}],"technique":null,"techniques":[],"computed":[],"activity":"Kwasowość (wolne kwasy tłuszczowe)\nZakres:\nZakres (0,05 - 45) %\nZ obliczeń","reference":"Ł","norm_bases":["Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Koncentraty spożywcze, Ryby i przetwory rybne, Mięso i produkty mięsne, Wyroby cukiernicze i ciastkarskie, Zboża i przetwory zbożowe, Wyroby garmażeryjne, Dodatki do żywności, Suplementy diety, Porcje żywnościowe, Oleje oraz tłuszcze roślinne i zwierzęce, Przetwory owocowo-warzywne, Sosy, Majonez, Nasiona oleiste, Pasze Kwasowość (wolne kwasy tłuszczowe)\nZakres:\nZakres (0,05 - 45) %\nZ obliczeń Ł Koncentraty spozywcze, Ryby i przetwory rybne, Mieso i produkty miesne, Wyroby cukiernicze i ciastkarskie, Zboza i przetwory zbozowe, Wyroby garmazeryjne, Dodatki do zywnosci, Suplementy diety, Porcje zywnosciowe, Oleje oraz tluszcze roslinne i zwierzece, Przetwory owocowo-warzywne, Sosy, Majonez, Nasiona oleiste, Pasze Kwasowosc (wolne kwasy tluszczowe)\nZakres:\nZakres (0,05 - 45) %\nZ obliczen L","categories":["food","petro","pharma"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acidity (free fatty acids)","parameters_en":[{"name":"Range","range":"(0,05 - 45) %"},{"name":"Calculated"}],"search_en":"Food concentrates, Fish and fish products, Meat and meat products, Confectionery and bakery products, Cereals and cereal products, Delicatessen products, Food additives, Food supplements, Food rations, Vegetable and animal oils and fats, Fruit and vegetable preserves, Sauces, Mayonnaise, Oilseeds, Feed Acidity (free fatty acids) Range Calculated Ł","test_object_en":"Food concentrates, Fish and fish products, Meat and meat products, Confectionery and bakery products, Cereals and cereal products, Delicatessen products, Food additives, Food supplements, Food rations, Vegetable and animal oils and fats, Fruit and vegetable preserves, Sauces, Mayonnaise, Oilseeds, Feed","parameters_zh":[{"name":"范围","range":"(0,05 - 45) %"},{"name":"由计算得出"}],"search_zh":"食品浓缩制品，鱼与鱼制品，肉与肉制品，糖果与糕点制品，谷物与谷物制品，熟食制品，食品添加剂，膳食补充剂 范围 由计算得出 Ł","test_object_zh":"食品浓缩制品，鱼与鱼制品，肉与肉制品，糖果与糕点制品，谷物与谷物制品，熟食制品，食品添加剂，膳食补充剂"},{"_id":"6a82c6ff884ede9a1b2c295a","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Przetwory owocowe i warzywne","methodology":"Kwasowość ogólna","parameters":[{"name":"Zakres","range":"(0,20 - 10)%"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość ogólna\nZakres (0,20 - 10)%\nMetoda miareczkowa","reference":"PN-A-75101-04:1990 | PN-A-75101-04:1990/Az1:2002 Ł","norm_bases":["PN-A-75101-04:1990","PN-A-75101-04:1990/Az1:2002 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory owocowe i warzywne Kwasowość ogólna\nZakres (0,20 - 10)%\nMetoda miareczkowa PN-A-75101-04:1990 | PN-A-75101-04:1990/Az1:2002 Ł Przetwory owocowe i warzywne Kwasowosc ogolna\nZakres (0,20 - 10)%\nMetoda miareczkowa PN-A-75101-04:1990 | PN-A-75101-04:1990/Az1:2002 L","categories":["other"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total acidity","parameters_en":[{"name":"Range","range":"(0,20 - 10)%"}],"search_en":"Fruit and vegetable preserves Total acidity Titrimetric method Range PN-A-75101-04:1990 | PN-A-75101-04:1990/Az1:2002 Ł","technique_en":"Titrimetric method","test_object_en":"Fruit and vegetable preserves","parameters_zh":[{"name":"范围","range":"(0,20 - 10)%"}],"search_zh":"水果与蔬菜腌渍制品 总酸度 滴定法 范围 PN-A-75101-04:1990 | PN-A-75101-04:1990/Az1:2002 Ł","technique_zh":"滴定法","methodology_zh":"总酸度","test_object_zh":"水果与蔬菜腌渍制品"},{"_id":"6a82c6ff884ede9a1b2c295b","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Przetwory owocowe i warzywne","methodology":"Zawartość ekstraktu ogólnego","parameters":[{"name":"Zakres","range":"(1,0 - 85)%"}],"technique":"Metoda refraktometryczna","techniques":["Metoda refraktometryczna"],"computed":[],"activity":"Zawartość ekstraktu ogólnego\nZakres (1,0 - 85)%\nMetoda refraktometryczna","reference":"PN-A-75101-02:1990 | PN-A-75101-02:1990/Az1:2002 Ł","norm_bases":["PN-A-75101-02:1990","PN-A-75101-02:1990/Az1:2002 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory owocowe i warzywne Zawartość ekstraktu ogólnego\nZakres (1,0 - 85)%\nMetoda refraktometryczna PN-A-75101-02:1990 | PN-A-75101-02:1990/Az1:2002 Ł Przetwory owocowe i warzywne Zawartosc ekstraktu ogolnego\nZakres (1,0 - 85)%\nMetoda refraktometryczna PN-A-75101-02:1990 | PN-A-75101-02:1990/Az1:2002 L","categories":["other"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total extract content","parameters_en":[{"name":"Range","range":"(1,0 - 85)%"}],"search_en":"Fruit and vegetable preserves Total extract content Refractometric method Range PN-A-75101-02:1990 | PN-A-75101-02:1990/Az1:2002 Ł","technique_en":"Refractometric method","test_object_en":"Fruit and vegetable preserves","parameters_zh":[{"name":"范围","range":"(1,0 - 85)%"}],"search_zh":"水果与蔬菜腌渍制品 总浸出物含量 折射法 范围 PN-A-75101-02:1990 | PN-A-75101-02:1990/Az1:2002 Ł","technique_zh":"折射法","methodology_zh":"总浸出物含量","test_object_zh":"水果与蔬菜腌渍制品"},{"_id":"6a82c6ff884ede9a1b2c295c","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Przetwory owocowe i warzywne","methodology":"Ekstrakt bezcukrowy (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekstrakt bezcukrowy (z obliczeń)","reference":"PN-A-75101-07:1990 Ł","norm_bases":["PN-A-75101-07:1990 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory owocowe i warzywne Ekstrakt bezcukrowy (z obliczeń) PN-A-75101-07:1990 Ł Przetwory owocowe i warzywne Ekstrakt bezcukrowy (z obliczen) PN-A-75101-07:1990 L","categories":["other"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sugar-free extract (calculated)","search_en":"Fruit and vegetable preserves Sugar-free extract (calculated) PN-A-75101-07:1990 Ł","test_object_en":"Fruit and vegetable preserves","search_zh":"水果与蔬菜腌渍制品 PN-A-75101-07:1990 Ł","test_object_zh":"水果与蔬菜腌渍制品"},{"_id":"6a82c6ff884ede9a1b2c295d","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Przetwory owocowe i warzywne","methodology":"Kwasowość ogólna","parameters":[{"name":"Zakres","range":"(0,30 - 70) g/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość ogólna\nZakres (0,30 - 70) g/l\nMetoda miareczkowa","reference":"PN-EN 12147:2000 Ł","norm_bases":["PN-EN 12147:2000 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory owocowe i warzywne Kwasowość ogólna\nZakres (0,30 - 70) g/l\nMetoda miareczkowa PN-EN 12147:2000 Ł Przetwory owocowe i warzywne Kwasowosc ogolna\nZakres (0,30 - 70) g/l\nMetoda miareczkowa PN-EN 12147:2000 L","categories":["other"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total acidity","parameters_en":[{"name":"Range","range":"(0,30 - 70) g/l"}],"search_en":"Fruit and vegetable preserves Total acidity Titrimetric method Range PN-EN 12147:2000 Ł","technique_en":"Titrimetric method","test_object_en":"Fruit and vegetable preserves","parameters_zh":[{"name":"范围","range":"(0,30 - 70) g/l"}],"search_zh":"水果与蔬菜腌渍制品 总酸度 滴定法 范围 PN-EN 12147:2000 Ł","technique_zh":"滴定法","methodology_zh":"总酸度","test_object_zh":"水果与蔬菜腌渍制品"},{"_id":"6a82c6ff884ede9a1b2c295e","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Przetwory owocowe i warzywne","methodology":"Zawartość ekstraktu","parameters":[{"name":"Zakres","range":"(1,0 - 85)%"}],"technique":"Metoda refraktometryczna","techniques":["Metoda refraktometryczna"],"computed":[],"activity":"Zawartość ekstraktu\nZakres (1,0 - 85)%\nMetoda refraktometryczna","reference":"PN-EN 12143:2000 Ł","norm_bases":["PN-EN 12143:2000 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory owocowe i warzywne Zawartość ekstraktu\nZakres (1,0 - 85)%\nMetoda refraktometryczna PN-EN 12143:2000 Ł Przetwory owocowe i warzywne Zawartosc ekstraktu\nZakres (1,0 - 85)%\nMetoda refraktometryczna PN-EN 12143:2000 L","categories":["other"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Extract content","parameters_en":[{"name":"Range","range":"(1,0 - 85)%"}],"search_en":"Fruit and vegetable preserves Extract content Refractometric method Range PN-EN 12143:2000 Ł","technique_en":"Refractometric method","test_object_en":"Fruit and vegetable preserves","parameters_zh":[{"name":"范围","range":"(1,0 - 85)%"}],"search_zh":"水果与蔬菜腌渍制品 浸出物含量 折射法 范围 PN-EN 12143:2000 Ł","technique_zh":"折射法","test_object_zh":"水果与蔬菜腌渍制品","methodology_zh":"浸出物含量"},{"_id":"6a82c6ff884ede9a1b2c295f","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Napoje bezalkoholowe","methodology":"Kwasowość ogólna","parameters":[{"name":"Zakres","range":"(0,20 - 10)%"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość ogólna\nZakres (0,20 - 10)%\nMetoda miareczkowa","reference":"PN-A-79033:1985 Ł","norm_bases":["PN-A-79033:1985 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje bezalkoholowe Kwasowość ogólna\nZakres (0,20 - 10)%\nMetoda miareczkowa PN-A-79033:1985 Ł Napoje bezalkoholowe Kwasowosc ogolna\nZakres (0,20 - 10)%\nMetoda miareczkowa PN-A-79033:1985 L","categories":["food"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total acidity","parameters_en":[{"name":"Range","range":"(0,20 - 10)%"}],"search_en":"Non-alcoholic beverages Total acidity Titrimetric method Range PN-A-79033:1985 Ł","technique_en":"Titrimetric method","test_object_en":"Non-alcoholic beverages","parameters_zh":[{"name":"范围","range":"(0,20 - 10)%"}],"search_zh":"无酒精饮料 总酸度 滴定法 范围 PN-A-79033:1985 Ł","technique_zh":"滴定法","test_object_zh":"无酒精饮料","methodology_zh":"总酸度"},{"_id":"6a82c6ff884ede9a1b2c2960","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Napoje bezalkoholowe","methodology":"Zawartość ekstraktu ogólnego","parameters":[{"name":"Zakres","range":"(1,0 - 85)%"}],"technique":"Metoda refraktometryczna","techniques":["Metoda refraktometryczna"],"computed":[],"activity":"Zawartość ekstraktu ogólnego\nZakres (1,0 - 85)%\nMetoda refraktometryczna","reference":"Ł","norm_bases":["Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje bezalkoholowe Zawartość ekstraktu ogólnego\nZakres (1,0 - 85)%\nMetoda refraktometryczna Ł Napoje bezalkoholowe Zawartosc ekstraktu ogolnego\nZakres (1,0 - 85)%\nMetoda refraktometryczna L","categories":["food"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total extract content","parameters_en":[{"name":"Range","range":"(1,0 - 85)%"}],"search_en":"Non-alcoholic beverages Total extract content Refractometric method Range Ł","technique_en":"Refractometric method","test_object_en":"Non-alcoholic beverages","parameters_zh":[{"name":"范围","range":"(1,0 - 85)%"}],"search_zh":"无酒精饮料 总浸出物含量 折射法 范围 Ł","technique_zh":"折射法","test_object_zh":"无酒精饮料","methodology_zh":"总浸出物含量"},{"_id":"6a82c6ff884ede9a1b2c2961","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Napoje bezalkoholowe","methodology":"Zawartość tlenku węgla (IV)","parameters":[{"name":"Zakres","range":"(1,0 – 8,0) g/l"}],"technique":"Metoda ciśnieniowa","techniques":["Metoda ciśnieniowa"],"computed":[],"activity":"Zawartość tlenku węgla (IV)\nZakres (1,0 – 8,0) g/l\nMetoda ciśnieniowa","reference":"PN-A-79033:1985 Ł","norm_bases":["PN-A-79033:1985 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje bezalkoholowe Zawartość tlenku węgla (IV)\nZakres (1,0 – 8,0) g/l\nMetoda ciśnieniowa PN-A-79033:1985 Ł Napoje bezalkoholowe Zawartosc tlenku wegla (IV)\nZakres (1,0 – 8,0) g/l\nMetoda cisnieniowa PN-A-79033:1985 L","categories":["food"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon (IV) oxide content","parameters_en":[{"name":"Range","range":"(1,0 – 8,0) g/l"}],"search_en":"Non-alcoholic beverages Carbon (IV) oxide content Pressure method Range PN-A-79033:1985 Ł","technique_en":"Pressure method","test_object_en":"Non-alcoholic beverages","parameters_zh":[{"name":"范围","range":"(1,0 – 8,0) g/l"}],"search_zh":"无酒精饮料 压力法 范围 PN-A-79033:1985 Ł","test_object_zh":"无酒精饮料","technique_zh":"压力法"},{"_id":"6a82c6ff884ede9a1b2c2962","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Ryby i przetwory rybne","methodology":"Kwasowość ogólna","parameters":[{"name":"Zakres","range":"(0,2 - 10)%"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość ogólna\nZakres (0,2 - 10)%\nMetoda miareczkowa","reference":"PN-A-86746:1974 Ł","norm_bases":["PN-A-86746:1974 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ryby i przetwory rybne Kwasowość ogólna\nZakres (0,2 - 10)%\nMetoda miareczkowa PN-A-86746:1974 Ł Ryby i przetwory rybne Kwasowosc ogolna\nZakres (0,2 - 10)%\nMetoda miareczkowa PN-A-86746:1974 L","categories":["other"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total acidity","parameters_en":[{"name":"Range","range":"(0,2 - 10)%"}],"search_en":"Fish and fish products Total acidity Titrimetric method Range PN-A-86746:1974 Ł","technique_en":"Titrimetric method","test_object_en":"Fish and fish products","parameters_zh":[{"name":"范围","range":"(0,2 - 10)%"}],"search_zh":"鱼与鱼制品 总酸度 滴定法 范围 PN-A-86746:1974 Ł","technique_zh":"滴定法","test_object_zh":"鱼与鱼制品","methodology_zh":"总酸度"},{"_id":"6a82c6ff884ede9a1b2c2963","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Zboża i przetwory zbożowe","methodology":"Kwasowość ogólna","parameters":[{"name":"Zakres","range":"(0,20 - 10)°"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość ogólna\nZakres (0,20 - 10)°\nMetoda miareczkowa","reference":"PN-A-74108:1996 Ł","norm_bases":["PN-A-74108:1996 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zboża i przetwory zbożowe Kwasowość ogólna\nZakres (0,20 - 10)°\nMetoda miareczkowa PN-A-74108:1996 Ł Zboza i przetwory zbozowe Kwasowosc ogolna\nZakres (0,20 - 10)°\nMetoda miareczkowa PN-A-74108:1996 L","categories":["other"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total acidity","parameters_en":[{"name":"Range","range":"(0,20 - 10)°"}],"search_en":"Cereals and cereal products Total acidity Titrimetric method Range PN-A-74108:1996 Ł","technique_en":"Titrimetric method","test_object_en":"Cereals and cereal products","parameters_zh":[{"name":"范围","range":"(0,20 - 10)°"}],"search_zh":"谷物与谷物制品 总酸度 滴定法 范围 PN-A-74108:1996 Ł","technique_zh":"滴定法","methodology_zh":"总酸度","test_object_zh":"谷物与谷物制品"},{"_id":"6a82c6ff884ede9a1b2c2964","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Zboża i przetwory zbożowe","methodology":"Kwasowość tłuszczowa","parameters":[{"name":"Zakres","range":"(0,50 – 70) mg KOH/100 g"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość tłuszczowa\nZakres (0,50 – 70) mg KOH/100 g\nMetoda miareczkowa","reference":"PN-ISO 7305:2001 Ł","norm_bases":["PN-ISO 7305:2001 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zboża i przetwory zbożowe Kwasowość tłuszczowa\nZakres (0,50 – 70) mg KOH/100 g\nMetoda miareczkowa PN-ISO 7305:2001 Ł Zboza i przetwory zbozowe Kwasowosc tluszczowa\nZakres (0,50 – 70) mg KOH/100 g\nMetoda miareczkowa PN-ISO 7305:2001 L","categories":["other"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fat acidity","parameters_en":[{"name":"Range","range":"(0,50 – 70) mg KOH/100 g"}],"search_en":"Cereals and cereal products Fat acidity Titrimetric method Range PN-ISO 7305:2001 Ł","technique_en":"Titrimetric method","test_object_en":"Cereals and cereal products","parameters_zh":[{"name":"范围","range":"(0,50 – 70) mg KOH/100 g"}],"search_zh":"谷物与谷物制品 滴定法 范围 PN-ISO 7305:2001 Ł","technique_zh":"滴定法","test_object_zh":"谷物与谷物制品"},{"_id":"6a82c6ff884ede9a1b2c2965","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Wyroby cukiernicze, Mleko i przetwory mleczne, Koncentraty spożywcze, Mięso i przetwory mięsne, Wyroby garmażeryjne, Kawa, Herbata, Oleje, tłuszcze zwierzęce i roślinne, Nasiona roślin oleistych, Ryby i przetwory rybne, Miód, Napoje bezalkoholowe, Napoje alkoholowe, Zboża i przetwory zbożowe, Przetwory owocowe i warzywne","methodology":"Wyróżniki jakości sensorycznej Analiza sensoryczna","parameters":[{"name":"Zakres","range":"1 – 5"}],"technique":"Metoda punktowa","techniques":["Metoda punktowa"],"computed":[],"activity":"Wyróżniki jakości sensorycznej Analiza sensoryczna\nZakres 1 – 5\nMetoda punktowa","reference":"PB-21/LF wyd. 9 z dnia 02.02.2022 Ł","norm_bases":["PB-21/LF wyd. 9 z dnia 02.02.2022 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby cukiernicze, Mleko i przetwory mleczne, Koncentraty spożywcze, Mięso i przetwory mięsne, Wyroby garmażeryjne, Kawa, Herbata, Oleje, tłuszcze zwierzęce i roślinne, Nasiona roślin oleistych, Ryby i przetwory rybne, Miód, Napoje bezalkoholowe, Napoje alkoholowe, Zboża i przetwory zbożowe, Przetwory owocowe i warzywne Wyróżniki jakości sensorycznej Analiza sensoryczna\nZakres 1 – 5\nMetoda punktowa PB-21/LF wyd. 9 z dnia 02.02.2022 Ł Wyroby cukiernicze, Mleko i przetwory mleczne, Koncentraty spozywcze, Mieso i przetwory miesne, Wyroby garmazeryjne, Kawa, Herbata, Oleje, tluszcze zwierzece i roslinne, Nasiona roslin oleistych, Ryby i przetwory rybne, Miod, Napoje bezalkoholowe, Napoje alkoholowe, Zboza i przetwory zbozowe, Przetwory owocowe i warzywne Wyrozniki jakosci sensorycznej Analiza sensoryczna\nZakres 1 – 5\nMetoda punktowa PB-21/LF wyd. 9 z dnia 02.02.2022 L","categories":["food","petro"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sensory quality attributes Sensory analysis","parameters_en":[{"name":"Range","range":"1 – 5"}],"search_en":"Confectionery products, Milk and milk products, Food concentrates, Meat and meat products, Delicatessen products, Coffee, Tea, Oils, animal and vegetable fats, Oilseeds, Fish and fish products, Honey, Non-alcoholic beverages, Alcoholic beverages, Cereals and cereal products, Fruit and vegetable preserves Sensory quality attributes Sensory analysis Point method Range PB-21/LF wyd. 9 z dnia 02.02.2022 Ł","technique_en":"Point method","test_object_en":"Confectionery products, Milk and milk products, Food concentrates, Meat and meat products, Delicatessen products, Coffee, Tea, Oils, animal and vegetable fats, Oilseeds, Fish and fish products, Honey, Non-alcoholic beverages, Alcoholic beverages, Cereals and cereal products, Fruit and vegetable preserves","parameters_zh":[{"name":"范围","range":"1 – 5"}],"search_zh":"点测法 范围 PB-21/LF wyd. 9 z dnia 02.02.2022 Ł","technique_zh":"点测法"},{"_id":"6a82c6ff884ede9a1b2c2966","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Materiały i wyroby przeznaczone do kontaktu z produktami spożywczymi - tworzywa sztuczne, Materiały i wyroby przeznaczone do kontaktu z produktami spożywczymi - papier, tektura","methodology":"Obcy zapach i smak przekazywany przy bezpośrednim kontakcie","parameters":[],"technique":"Metoda trójkątowa; Prosty test opisowy","techniques":["Metoda trójkątowa","Prosty test opisowy"],"computed":[],"activity":"Obcy zapach i smak przekazywany przy bezpośrednim kontakcie\nMetoda trójkątowa; Prosty test opisowy","reference":"PB-255/LF wyd. 4 z dnia 02.02.2022 Ł","norm_bases":["PB-255/LF wyd. 4 z dnia 02.02.2022 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby przeznaczone do kontaktu z produktami spożywczymi - tworzywa sztuczne, Materiały i wyroby przeznaczone do kontaktu z produktami spożywczymi - papier, tektura Obcy zapach i smak przekazywany przy bezpośrednim kontakcie\nMetoda trójkątowa; Prosty test opisowy PB-255/LF wyd. 4 z dnia 02.02.2022 Ł Materialy i wyroby przeznaczone do kontaktu z produktami spozywczymi - tworzywa sztuczne, Materialy i wyroby przeznaczone do kontaktu z produktami spozywczymi - papier, tektura Obcy zapach i smak przekazywany przy bezposrednim kontakcie\nMetoda trojkatowa; Prosty test opisowy PB-255/LF wyd. 4 z dnia 02.02.2022 L","categories":["materials"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Foreign odour and taste transferred on direct contact","search_en":"Materials and articles intended to come into contact with foodstuffs - plastics, Materials and articles intended to come into contact with foodstuffs - paper, board Foreign odour and taste transferred on direct contact PB-255/LF wyd. 4 z dnia 02.02.2022 Ł","test_object_en":"Materials and articles intended to come into contact with foodstuffs - plastics, Materials and articles intended to come into contact with foodstuffs - paper, board"},{"_id":"6a82c6ff884ede9a1b2c2967","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Mleko i przetwory mleczne","methodology":"Kwasowość","parameters":[{"name":"Zakres","range":"(0,50 - 90)oSH"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość\nZakres (0,50 - 90)oSH\nMetoda miareczkowa","reference":"PB-79/LF wyd. 4 z dnia 03.01.2022 Ł","norm_bases":["PB-79/LF wyd. 4 z dnia 03.01.2022 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko i przetwory mleczne Kwasowość\nZakres (0,50 - 90)oSH\nMetoda miareczkowa PB-79/LF wyd. 4 z dnia 03.01.2022 Ł Mleko i przetwory mleczne Kwasowosc\nZakres (0,50 - 90)oSH\nMetoda miareczkowa PB-79/LF wyd. 4 z dnia 03.01.2022 L","categories":["food"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acidity","parameters_en":[{"name":"Range","range":"(0,50 - 90)oSH"}],"search_en":"Milk and milk products Acidity Titrimetric method Range PB-79/LF wyd. 4 z dnia 03.01.2022 Ł","technique_en":"Titrimetric method","test_object_en":"Milk and milk products","methodology_zh":"酸度","parameters_zh":[{"name":"范围","range":"(0,50 - 90)oSH"}],"search_zh":"乳与乳制品 酸度 滴定法 范围 PB-79/LF wyd. 4 z dnia 03.01.2022 Ł","technique_zh":"滴定法","test_object_zh":"乳与乳制品"},{"_id":"6a82c6ff884ede9a1b2c2968","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Herbata","methodology":"Wyciąg wodny","parameters":[{"name":"Zakres","range":"(1,0 – 50,0)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Wyciąg wodny\nZakres (1,0 – 50,0)%\nMetoda wagowa","reference":"PN-ISO 9768:1996 | PN-ISO 9768:1996/AC1:2000 Ł","norm_bases":["PN-ISO 9768:1996","PN-ISO 9768:1996/AC1:2000 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Herbata Wyciąg wodny\nZakres (1,0 – 50,0)%\nMetoda wagowa PN-ISO 9768:1996 | PN-ISO 9768:1996/AC1:2000 Ł Herbata Wyciag wodny\nZakres (1,0 – 50,0)%\nMetoda wagowa PN-ISO 9768:1996 | PN-ISO 9768:1996/AC1:2000 L","categories":["other"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water extract","parameters_en":[{"name":"Range","range":"(1,0 – 50,0)%"}],"search_en":"Tea Water extract Gravimetric method Range PN-ISO 9768:1996 | PN-ISO 9768:1996/AC1:2000 Ł","technique_en":"Gravimetric method","test_object_en":"Tea","parameters_zh":[{"name":"范围","range":"(1,0 – 50,0)%"}],"search_zh":"茶 重量法 范围 PN-ISO 9768:1996 | PN-ISO 9768:1996/AC1:2000 Ł","technique_zh":"重量法","test_object_zh":"茶"},{"_id":"6a82c6ff884ede9a1b2c2969","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Herbata","methodology":"Zawartość popiołu rozpuszczalnego i nierozpuszczalnego w wodzie","parameters":[{"name":"Zakres","range":"(0,02 – 40)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu rozpuszczalnego i nierozpuszczalnego w wodzie\nZakres (0,02 – 40)%\nMetoda wagowa","reference":"PN-ISO 1576:1996 Ł","norm_bases":["PN-ISO 1576:1996 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Herbata Zawartość popiołu rozpuszczalnego i nierozpuszczalnego w wodzie\nZakres (0,02 – 40)%\nMetoda wagowa PN-ISO 1576:1996 Ł Herbata Zawartosc popiolu rozpuszczalnego i nierozpuszczalnego w wodzie\nZakres (0,02 – 40)%\nMetoda wagowa PN-ISO 1576:1996 L","categories":["other"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,02 – 40)%"}],"search_en":"Tea Gravimetric method Range PN-ISO 1576:1996 Ł","technique_en":"Gravimetric method","test_object_en":"Tea","parameters_zh":[{"name":"范围","range":"(0,02 – 40)%"}],"search_zh":"茶 重量法 范围 PN-ISO 1576:1996 Ł","technique_zh":"重量法","test_object_zh":"茶"},{"_id":"6a82c6ff884ede9a1b2c296a","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Herbata","methodology":"Alkaliczność popiołu","parameters":[{"name":"Zakres","range":"(0,5 – 3,0)% KOH"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Alkaliczność popiołu\nZakres (0,5 – 3,0)% KOH\nMetoda miareczkowa","reference":"PN-ISO 1578:1996 Ł","norm_bases":["PN-ISO 1578:1996 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Herbata Alkaliczność popiołu\nZakres (0,5 – 3,0)% KOH\nMetoda miareczkowa PN-ISO 1578:1996 Ł Herbata Alkalicznosc popiolu\nZakres (0,5 – 3,0)% KOH\nMetoda miareczkowa PN-ISO 1578:1996 L","categories":["other"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash alkalinity","parameters_en":[{"name":"Range","range":"(0,5 – 3,0)% KOH"}],"search_en":"Tea Ash alkalinity Titrimetric method Range PN-ISO 1578:1996 Ł","technique_en":"Titrimetric method","test_object_en":"Tea","parameters_zh":[{"name":"范围","range":"(0,5 – 3,0)% KOH"}],"search_zh":"茶 滴定法 范围 PN-ISO 1578:1996 Ł","technique_zh":"滴定法","test_object_zh":"茶"},{"_id":"6a82c6ff884ede9a1b2c296b","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Koncentraty spożywcze, Przetwory owocowe i warzywne, Napoje bezalkoholowe, Kawa, Herbata, Dodatki do żywności, Suplementy diety, Wyroby garmażeryjne","methodology":"Gęstość","parameters":[{"name":"Zakres","range":"(0,80 – 2,00) g/ml"}],"technique":"Metoda piknometryczna","techniques":["Metoda piknometryczna"],"computed":[],"activity":"Gęstość\nZakres (0,80 – 2,00) g/ml\nMetoda piknometryczna","reference":"PB-85/LF wyd. 3 z dnia 03.01.2022 Ł","norm_bases":["PB-85/LF wyd. 3 z dnia 03.01.2022 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Koncentraty spożywcze, Przetwory owocowe i warzywne, Napoje bezalkoholowe, Kawa, Herbata, Dodatki do żywności, Suplementy diety, Wyroby garmażeryjne Gęstość\nZakres (0,80 – 2,00) g/ml\nMetoda piknometryczna PB-85/LF wyd. 3 z dnia 03.01.2022 Ł Koncentraty spozywcze, Przetwory owocowe i warzywne, Napoje bezalkoholowe, Kawa, Herbata, Dodatki do zywnosci, Suplementy diety, Wyroby garmazeryjne Gestosc\nZakres (0,80 – 2,00) g/ml\nMetoda piknometryczna PB-85/LF wyd. 3 z dnia 03.01.2022 L","categories":["food","pharma"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density","parameters_en":[{"name":"Range","range":"(0,80 – 2,00) g/ml"}],"search_en":"Food concentrates, Fruit and vegetable products, Non-alcoholic beverages, Coffee, Tea, Food additives, Dietary supplements, Delicatessen products Density Pycnometric method Range PB-85/LF wyd. 3 z dnia 03.01.2022 Ł","technique_en":"Pycnometric method","test_object_en":"Food concentrates, Fruit and vegetable products, Non-alcoholic beverages, Coffee, Tea, Food additives, Dietary supplements, Delicatessen products","methodology_zh":"密度","parameters_zh":[{"name":"范围","range":"(0,80 – 2,00) g/ml"}],"search_zh":"密度 比重瓶法 范围 PB-85/LF wyd. 3 z dnia 03.01.2022 Ł","technique_zh":"比重瓶法"},{"_id":"6a82c6ff884ede9a1b2c296c","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Zboża i przetwory zbożowe, Kawa, Herbata, Dodatki do żywności, Nasiona roślin oleistych, Koncentraty spożywcze, Chemia gospodarcza","methodology":"Gęstość nasypowa","parameters":[{"name":"Zakres","range":"(100 – 1000) g/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Gęstość nasypowa\nZakres (100 – 1000) g/l\nMetoda wagowa","reference":"PB-85/LF wyd. 3 z dnia 03.01.2022 Ł","norm_bases":["PB-85/LF wyd. 3 z dnia 03.01.2022 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zboża i przetwory zbożowe, Kawa, Herbata, Dodatki do żywności, Nasiona roślin oleistych, Koncentraty spożywcze, Chemia gospodarcza Gęstość nasypowa\nZakres (100 – 1000) g/l\nMetoda wagowa PB-85/LF wyd. 3 z dnia 03.01.2022 Ł Zboza i przetwory zbozowe, Kawa, Herbata, Dodatki do zywnosci, Nasiona roslin oleistych, Koncentraty spozywcze, Chemia gospodarcza Gestosc nasypowa\nZakres (100 – 1000) g/l\nMetoda wagowa PB-85/LF wyd. 3 z dnia 03.01.2022 L","categories":["food"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bulk density","parameters_en":[{"name":"Range","range":"(100 – 1000) g/l"}],"search_en":"Cereals and cereal products, Coffee, Tea, Food additives, Oilseeds, Food concentrates, Household chemicals Bulk density Gravimetric method Range PB-85/LF wyd. 3 z dnia 03.01.2022 Ł","technique_en":"Gravimetric method","test_object_en":"Cereals and cereal products, Coffee, Tea, Food additives, Oilseeds, Food concentrates, Household chemicals","parameters_zh":[{"name":"范围","range":"(100 – 1000) g/l"}],"search_zh":"堆积密度 重量法 范围 PB-85/LF wyd. 3 z dnia 03.01.2022 Ł","technique_zh":"重量法","methodology_zh":"堆积密度"},{"_id":"6a82c6ff884ede9a1b2c296d","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Mleko i przetwory mleczne, Koncentraty spożywcze, Owoce i warzywa, Przetwory owocowe i warzywne, Ryby i przetwory rybne, Wyroby cukiernicze, Zboża i przetwory zbożowe, Wyroby garmażeryjne, Napoje bezalkoholowe, Napoje alkoholowe, Kawa, Herbata, Dodatki do żywności, Suplementy diety, Racje żywnościowe, Mięso i przetwory mięsne","methodology":"pH","parameters":[{"name":"Zakres","range":"(3,0 – 10)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (3,0 – 10)\nMetoda potencjometryczna","reference":"PB-56/LF wyd. 6 z dnia 03.01.2022 Ł","norm_bases":["PB-56/LF wyd. 6 z dnia 03.01.2022 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko i przetwory mleczne, Koncentraty spożywcze, Owoce i warzywa, Przetwory owocowe i warzywne, Ryby i przetwory rybne, Wyroby cukiernicze, Zboża i przetwory zbożowe, Wyroby garmażeryjne, Napoje bezalkoholowe, Napoje alkoholowe, Kawa, Herbata, Dodatki do żywności, Suplementy diety, Racje żywnościowe, Mięso i przetwory mięsne pH\nZakres (3,0 – 10)\nMetoda potencjometryczna PB-56/LF wyd. 6 z dnia 03.01.2022 Ł Mleko i przetwory mleczne, Koncentraty spozywcze, Owoce i warzywa, Przetwory owocowe i warzywne, Ryby i przetwory rybne, Wyroby cukiernicze, Zboza i przetwory zbozowe, Wyroby garmazeryjne, Napoje bezalkoholowe, Napoje alkoholowe, Kawa, Herbata, Dodatki do zywnosci, Suplementy diety, Racje zywnosciowe, Mieso i przetwory miesne pH\nZakres (3,0 – 10)\nMetoda potencjometryczna PB-56/LF wyd. 6 z dnia 03.01.2022 L","categories":["food","pharma"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"(3,0 – 10)"}],"search_en":"Milk and dairy products, Food concentrates, Fruit and vegetables, Fruit and vegetable products, Fish and fish products, Confectionery products, Cereals and cereal products, Delicatessen products, Non-alcoholic beverages, Alcoholic beverages, Coffee, Tea, Food additives, Food supplements, Food rations, Meat and meat products pH Potentiometric method Range PB-56/LF wyd. 6 z dnia 03.01.2022 Ł","technique_en":"Potentiometric method","test_object_en":"Milk and dairy products, Food concentrates, Fruit and vegetables, Fruit and vegetable products, Fish and fish products, Confectionery products, Cereals and cereal products, Delicatessen products, Non-alcoholic beverages, Alcoholic beverages, Coffee, Tea, Food additives, Food supplements, Food rations, Meat and meat products","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(3,0 – 10)"}],"search_zh":"pH 值 电位法 范围 PB-56/LF wyd. 6 z dnia 03.01.2022 Ł","technique_zh":"电位法"},{"_id":"6a82c6ff884ede9a1b2c296e","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Mleko i przetwory mleczne","methodology":"Zawartość azotu pochodzącego z niezdenaturowanych białek serwatkowych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość azotu pochodzącego z niezdenaturowanych białek serwatkowych (z obliczeń)","reference":"PB-155/LF wyd. 4 z dnia 03.01.2022 Ł","norm_bases":["PB-155/LF wyd. 4 z dnia 03.01.2022 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko i przetwory mleczne Zawartość azotu pochodzącego z niezdenaturowanych białek serwatkowych (z obliczeń) PB-155/LF wyd. 4 z dnia 03.01.2022 Ł Mleko i przetwory mleczne Zawartosc azotu pochodzacego z niezdenaturowanych bialek serwatkowych (z obliczen) PB-155/LF wyd. 4 z dnia 03.01.2022 L","categories":["food"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of nitrogen from undenatured whey proteins (calculated)","search_en":"Milk and milk products Content of nitrogen from undenatured whey proteins (calculated) PB-155/LF wyd. 4 z dnia 03.01.2022 Ł","test_object_en":"Milk and milk products","search_zh":"乳与乳制品 PB-155/LF wyd. 4 z dnia 03.01.2022 Ł","test_object_zh":"乳与乳制品"},{"_id":"6a82c6ff884ede9a1b2c296f","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Ryby i przetwory rybne, Owoce morza i ich przetwory","methodology":"Zawartość glazury","parameters":[{"name":"Zakres","range":"(1,0 – 35)% m/m"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość glazury\nZakres (1,0 – 35)% m/m\nMetoda wagowa","reference":"PB-154/LF wyd. 3 z dnia 03.01.2022 Ł","norm_bases":["PB-154/LF wyd. 3 z dnia 03.01.2022 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ryby i przetwory rybne, Owoce morza i ich przetwory Zawartość glazury\nZakres (1,0 – 35)% m/m\nMetoda wagowa PB-154/LF wyd. 3 z dnia 03.01.2022 Ł Ryby i przetwory rybne, Owoce morza i ich przetwory Zawartosc glazury\nZakres (1,0 – 35)% m/m\nMetoda wagowa PB-154/LF wyd. 3 z dnia 03.01.2022 L","categories":["other"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Glaze content","parameters_en":[{"name":"Range","range":"(1,0 – 35)% m/m"}],"search_en":"Fish and fish products, Seafood and seafood products Glaze content Gravimetric method Range PB-154/LF wyd. 3 z dnia 03.01.2022 Ł","technique_en":"Gravimetric method","test_object_en":"Fish and fish products, Seafood and seafood products","parameters_zh":[{"name":"范围","range":"(1,0 – 35)% m/m"}],"search_zh":"鱼与鱼制品、海产品及其制品 冰衣含量 重量法 范围 PB-154/LF wyd. 3 z dnia 03.01.2022 Ł","technique_zh":"重量法","methodology_zh":"冰衣含量","test_object_zh":"鱼与鱼制品、海产品及其制品"},{"_id":"6a82c6ff884ede9a1b2c2970","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Owoce i warzywa, Przetwory owocowe i warzywne, Napoje alkoholowe, Ocet","methodology":"Zawartość tlenku siarki (IV)","parameters":[{"name":"Zakres","range":"(5,0 - 500) mg/kg"}],"technique":"Metoda jodometryczna","techniques":["Metoda jodometryczna"],"computed":[],"activity":"Zawartość tlenku siarki (IV)\nZakres (5,0 - 500) mg/kg\nMetoda jodometryczna","reference":"PB-111/LF wyd. 4 z dnia 03.01.2022 Ł","norm_bases":["PB-111/LF wyd. 4 z dnia 03.01.2022 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Owoce i warzywa, Przetwory owocowe i warzywne, Napoje alkoholowe, Ocet Zawartość tlenku siarki (IV)\nZakres (5,0 - 500) mg/kg\nMetoda jodometryczna PB-111/LF wyd. 4 z dnia 03.01.2022 Ł Owoce i warzywa, Przetwory owocowe i warzywne, Napoje alkoholowe, Ocet Zawartosc tlenku siarki (IV)\nZakres (5,0 - 500) mg/kg\nMetoda jodometryczna PB-111/LF wyd. 4 z dnia 03.01.2022 L","categories":["food"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur (IV) oxide content","parameters_en":[{"name":"Range","range":"(5,0 - 500) mg/kg"}],"search_en":"Fruit and vegetables, Fruit and vegetable products, Alcoholic beverages, Vinegar Sulfur (IV) oxide content Iodometric method Range PB-111/LF wyd. 4 z dnia 03.01.2022 Ł","technique_en":"Iodometric method","test_object_en":"Fruit and vegetables, Fruit and vegetable products, Alcoholic beverages, Vinegar","parameters_zh":[{"name":"范围","range":"(5,0 - 500) mg/kg"}],"search_zh":"范围 PB-111/LF wyd. 4 z dnia 03.01.2022 Ł"},{"_id":"6a82c6ff884ede9a1b2c2971","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda","methodology":"Liczba progowa smaku TFN","parameters":[{"name":"Zakres","range":"(1 - 6)"}],"technique":"Metoda parzysta, pełna, wybór niewymuszony","techniques":["Metoda parzysta, pełna, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa smaku TFN\nZakres (1 - 6)\nMetoda parzysta, pełna, wybór niewymuszony","reference":"PN-EN 1622:2006 Ł","norm_bases":["PN-EN 1622:2006 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba progowa smaku TFN\nZakres (1 - 6)\nMetoda parzysta, pełna, wybór niewymuszony PN-EN 1622:2006 Ł Woda Liczba progowa smaku TFN\nZakres (1 - 6)\nMetoda parzysta, pelna, wybor niewymuszony PN-EN 1622:2006 L","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Taste threshold number TFN","parameters_en":[{"name":"Range","range":"(1 - 6)"}],"search_en":"Water Taste threshold number TFN Paired method, full, non-forced choice Range PN-EN 1622:2006 Ł","technique_en":"Paired method, full, non-forced choice","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(1 - 6)"}],"search_zh":"水 味阈值 TFN 范围 PN-EN 1622:2006 Ł","test_object_zh":"水","methodology_zh":"味阈值 TFN"},{"_id":"6a82c6ff884ede9a1b2c2972","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda","methodology":"Liczba progowa zapachu TON","parameters":[{"name":"Zakres","range":"(1 – 6)"}],"technique":"Metoda parzysta, pełna, wybór niewymuszony","techniques":["Metoda parzysta, pełna, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa zapachu TON\nZakres (1 – 6)\nMetoda parzysta, pełna, wybór niewymuszony","reference":"Ł","norm_bases":["Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba progowa zapachu TON\nZakres (1 – 6)\nMetoda parzysta, pełna, wybór niewymuszony Ł Woda Liczba progowa zapachu TON\nZakres (1 – 6)\nMetoda parzysta, pelna, wybor niewymuszony L","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Odour threshold number TON","parameters_en":[{"name":"Range","range":"(1 – 6)"}],"search_en":"Water Odour threshold number TON Paired method, full, non-forced choice Range Ł","technique_en":"Paired method, full, non-forced choice","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(1 – 6)"}],"search_zh":"水 嗅阈值 TON 范围 Ł","test_object_zh":"水","methodology_zh":"嗅阈值 TON"},{"_id":"6a82c6ff884ede9a1b2c2973","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Materiały i wyroby: - tworzywa sztuczne - papier, tektura","methodology":"Zawartość pierwiastków","parameters":[{"name":"kadm","range":"(0,50 – 50,0) mg/kg"},{"name":"ołów","range":"(1,00 – 50,0) mg/kg"},{"name":"rtęć","range":"(0,50 – 25,0) mg/kg"}],"technique":"Metoda spektrometrii mas ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP MS)","techniques":["Metoda spektrometrii mas ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP MS)"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\nkadm (0,50 – 50,0) mg/kg\nołów (1,00 – 50,0) mg/kg\nrtęć (0,50 – 25,0) mg/kg\nMetoda spektrometrii mas ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP MS)","reference":"PB-268/LF wyd. 3 z dnia 07.02.2022 Ł","norm_bases":["PB-268/LF wyd. 3 z dnia 07.02.2022 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby: - tworzywa sztuczne - papier, tektura Zawartość pierwiastków\nZakres:\nkadm (0,50 – 50,0) mg/kg\nołów (1,00 – 50,0) mg/kg\nrtęć (0,50 – 25,0) mg/kg\nMetoda spektrometrii mas ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP MS) PB-268/LF wyd. 3 z dnia 07.02.2022 Ł Materialy i wyroby: - tworzywa sztuczne - papier, tektura Zawartosc pierwiastkow\nZakres:\nkadm (0,50 – 50,0) mg/kg\nolow (1,00 – 50,0) mg/kg\nrtec (0,50 – 25,0) mg/kg\nMetoda spektrometrii mas ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP MS) PB-268/LF wyd. 3 z dnia 07.02.2022 L","categories":["materials"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","parameters_en":[{"name":"cadmium","range":"(0,50 – 50,0) mg/kg"},{"name":"lead","range":"(1,00 – 50,0) mg/kg"},{"name":"mercury","range":"(0,50 – 25,0) mg/kg"}],"search_en":"Materials and articles: - plastics - paper, cardboard Element content Inductively coupled plasma mass spectrometry method (ICP MS) cadmium lead mercury PB-268/LF wyd. 3 z dnia 07.02.2022 Ł","technique_en":"Inductively coupled plasma mass spectrometry method (ICP MS)","test_object_en":"Materials and articles: - plastics - paper, cardboard","methodology_zh":"元素含量","parameters_zh":[{"name":"镉","range":"(0,50 – 50,0) mg/kg"},{"name":"铅","range":"(1,00 – 50,0) mg/kg"},{"name":"汞","range":"(0,50 – 25,0) mg/kg"}],"search_zh":"元素含量 镉 铅 汞 PB-268/LF wyd. 3 z dnia 07.02.2022 Ł"},{"_id":"6a82c6ff884ede9a1b2c2974","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Materiały i wyroby: - tworzywa sztuczne - papier, tektura","methodology":"Zawartość chromu(VI)","parameters":[{"name":"Zakres","range":"(0,50 – 5,0) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość chromu(VI)\nZakres (0,50 – 5,0) mg/kg\nMetoda spektrofotometryczna","reference":"PB-269/LF wyd. 2 z dnia 07.02.2022 Ł","norm_bases":["PB-269/LF wyd. 2 z dnia 07.02.2022 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby: - tworzywa sztuczne - papier, tektura Zawartość chromu(VI)\nZakres (0,50 – 5,0) mg/kg\nMetoda spektrofotometryczna PB-269/LF wyd. 2 z dnia 07.02.2022 Ł Materialy i wyroby: - tworzywa sztuczne - papier, tektura Zawartosc chromu(VI)\nZakres (0,50 – 5,0) mg/kg\nMetoda spektrofotometryczna PB-269/LF wyd. 2 z dnia 07.02.2022 L","categories":["materials"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium(VI) content","parameters_en":[{"name":"Range","range":"(0,50 – 5,0) mg/kg"}],"search_en":"Materials and articles: - plastics - paper, cardboard Chromium(VI) content Spectrophotometric method Range PB-269/LF wyd. 2 z dnia 07.02.2022 Ł","technique_en":"Spectrophotometric method","test_object_en":"Materials and articles: - plastics - paper, cardboard","parameters_zh":[{"name":"范围","range":"(0,50 – 5,0) mg/kg"}],"search_zh":"分光光度法 范围 PB-269/LF wyd. 2 z dnia 07.02.2022 Ł","technique_zh":"分光光度法"},{"_id":"6a82c6ff884ede9a1b2c2975","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Mięso i przetwory mięsne, Mleko i przetwory mleczne, Ryby i przetwory rybne, Wyroby cukiernicze, Oleje, tłuszcze zwierzęce i roślinne, Zboża i przetwory zbożowe, Dodatki do żywności, Wyroby garmażeryjne, Racje żywnościowe, Suplementy diety, Koncentraty spożywcze","methodology":"Zawartość cholesterolu","parameters":[{"name":"Cholesterol","range":"(1,0 – 3000) mg/100g"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość cholesterolu\nCholesterol (1,0 – 3000) mg/100g\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PB-110/LF wyd. 3 z dnia 10.01.2022 Ł","norm_bases":["PB-110/LF wyd. 3 z dnia 10.01.2022 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne, Mleko i przetwory mleczne, Ryby i przetwory rybne, Wyroby cukiernicze, Oleje, tłuszcze zwierzęce i roślinne, Zboża i przetwory zbożowe, Dodatki do żywności, Wyroby garmażeryjne, Racje żywnościowe, Suplementy diety, Koncentraty spożywcze Zawartość cholesterolu\nCholesterol (1,0 – 3000) mg/100g\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PB-110/LF wyd. 3 z dnia 10.01.2022 Ł Mieso i przetwory miesne, Mleko i przetwory mleczne, Ryby i przetwory rybne, Wyroby cukiernicze, Oleje, tluszcze zwierzece i roslinne, Zboza i przetwory zbozowe, Dodatki do zywnosci, Wyroby garmazeryjne, Racje zywnosciowe, Suplementy diety, Koncentraty spozywcze Zawartosc cholesterolu\nCholesterol (1,0 – 3000) mg/100g\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PB-110/LF wyd. 3 z dnia 10.01.2022 L","categories":["food","petro","pharma"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cholesterol content","parameters_en":[{"name":"Cholesterol","range":"(1,0 – 3000) mg/100g"}],"search_en":"Meat and meat products, Milk and dairy products, Fish and fish products, Confectionery products, Oils, animal and vegetable fats, Cereals and cereal products, Food additives, Delicatessen products, Food rations, Food supplements, Food concentrates Cholesterol content Gas chromatography with flame ionization detection (GC-FID) Cholesterol PB-110/LF wyd. 3 z dnia 10.01.2022 Ł","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Meat and meat products, Milk and dairy products, Fish and fish products, Confectionery products, Oils, animal and vegetable fats, Cereals and cereal products, Food additives, Delicatessen products, Food rations, Food supplements, Food concentrates","search_zh":"胆固醇含量 气相色谱-氢火焰离子化检测法（GC-FID） PB-110/LF wyd. 3 z dnia 10.01.2022 Ł","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"胆固醇含量"},{"_id":"6a82c6ff884ede9a1b2c2976","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Materiały i wyroby przeznaczone do kontaktu z produktami spożywczymi - tworzywa sztuczne","methodology":"Migracja globalna do płynów modelowych przez całkowite zanurzenie/z zastosowaniem torebki/ przez napełnienie wyrobu","parameters":[{"name":"Zakres","range":"(0,5 – 15) mg/dm2"},{"name":"Zakres","range":"(3,0 - 70) mg/kg"},{"name":"Płyny modelowe: Woda Kwas octowy 3% Etanol 10% Etanol 20% Etanol 50% Etanol 95% Izooktan"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Migracja globalna do płynów modelowych przez całkowite zanurzenie/z zastosowaniem torebki/ przez napełnienie wyrobu\nZakres:\nZakres (0,5 – 15) mg/dm2\nZakres (3,0 - 70) mg/kg\nPłyny modelowe: Woda Kwas octowy 3% Etanol 10% Etanol 20% Etanol 50% Etanol 95% Izooktan\nMetoda wagowa","reference":"PN-EN 1186-3:2023-01 Ł","norm_bases":["PN-EN 1186-3:2023-01 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby przeznaczone do kontaktu z produktami spożywczymi - tworzywa sztuczne Migracja globalna do płynów modelowych przez całkowite zanurzenie/z zastosowaniem torebki/ przez napełnienie wyrobu\nZakres:\nZakres (0,5 – 15) mg/dm2\nZakres (3,0 - 70) mg/kg\nPłyny modelowe: Woda Kwas octowy 3% Etanol 10% Etanol 20% Etanol 50% Etanol 95% Izooktan\nMetoda wagowa PN-EN 1186-3:2023-01 Ł Materialy i wyroby przeznaczone do kontaktu z produktami spozywczymi - tworzywa sztuczne Migracja globalna do plynow modelowych przez calkowite zanurzenie/z zastosowaniem torebki/ przez napelnienie wyrobu\nZakres:\nZakres (0,5 – 15) mg/dm2\nZakres (3,0 - 70) mg/kg\nPlyny modelowe: Woda Kwas octowy 3% Etanol 10% Etanol 20% Etanol 50% Etanol 95% Izooktan\nMetoda wagowa PN-EN 1186-3:2023-01 L","categories":["materials","water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Overall migration into food simulants by total immersion/using a pouch/ by filling the article","parameters_en":[{"name":"Range","range":"(0,5 – 15) mg/dm2"},{"name":"Range","range":"(3,0 - 70) mg/kg"},{"name":"Simulants: Water Acetic acid 3% Ethanol 10% Ethanol 20% Ethanol 50% Ethanol 95% Isooctane"}],"search_en":"Materials and articles intended to come into contact with foodstuffs - plastics Overall migration into food simulants by total immersion/using a pouch/ by filling the article Gravimetric method Range Range Simulants: Water Acetic acid 3% Ethanol 10% Ethanol 20% Ethanol 50% Ethanol 95% Isooctane PN-EN 1186-3:2023-01 Ł","technique_en":"Gravimetric method","test_object_en":"Materials and articles intended to come into contact with foodstuffs - plastics","parameters_zh":[{"name":"范围","range":"(0,5 – 15) mg/dm2"},{"name":"范围","range":"(3,0 - 70) mg/kg"},{"name":"Płyny modelowe: Woda Kwas octowy 3% Etanol 10% Etanol 20% Etanol 50% Etanol 95% Izooktan"}],"search_zh":"重量法 范围 范围 PN-EN 1186-3:2023-01 Ł","technique_zh":"重量法"},{"_id":"6a82c6ff884ede9a1b2c2977","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Opakowania hermetycznie zamknięte","methodology":"Szczelność","parameters":[],"technique":"Metoda wizualna; Metoda przez zanurzenie; Metoda suszarkowo-próżniowa","techniques":["Metoda wizualna","Metoda przez zanurzenie","Metoda suszarkowo-próżniowa"],"computed":[],"activity":"Szczelność\nMetoda wizualna; Metoda przez zanurzenie; Metoda suszarkowo-próżniowa","reference":"PB-55/LF wyd. 5 z dnia 03.01.2022 Ł","norm_bases":["PB-55/LF wyd. 5 z dnia 03.01.2022 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Opakowania hermetycznie zamknięte Szczelność\nMetoda wizualna; Metoda przez zanurzenie; Metoda suszarkowo-próżniowa PB-55/LF wyd. 5 z dnia 03.01.2022 Ł Opakowania hermetycznie zamkniete Szczelnosc\nMetoda wizualna; Metoda przez zanurzenie; Metoda suszarkowo-prozniowa PB-55/LF wyd. 5 z dnia 03.01.2022 L","categories":["other"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Leak tightness","search_en":"Hermetically sealed packaging Leak tightness Visual method; Immersion method; Oven-vacuum method PB-55/LF wyd. 5 z dnia 03.01.2022 Ł","technique_en":"Visual method; Immersion method; Oven-vacuum method","test_object_en":"Hermetically sealed packaging","methodology_zh":"密封性","search_zh":"密封性 PB-55/LF wyd. 5 z dnia 03.01.2022 Ł"},{"_id":"6a82c6ff884ede9a1b2c2978","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Miód","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(14,0 – 27)%"}],"technique":"Metoda refraktometryczna","techniques":["Metoda refraktometryczna"],"computed":[],"activity":"Zawartość wody\nZakres (14,0 – 27)%\nMetoda refraktometryczna","reference":"PN-A-77626:1988 p. 5.3.3 | Rozporządzenie MRiRW z dnia 14.01.2009 (Dz.U.Nr 17, poz. 94) p. I ze zm. Ł","norm_bases":["PN-A-77626:1988 p. 5.3.3","Rozporządzenie MRiRW z dnia 14.01.2009 (Dz.U.Nr 17, poz. 94) p. I ze zm. Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Miód Zawartość wody\nZakres (14,0 – 27)%\nMetoda refraktometryczna PN-A-77626:1988 p. 5.3.3 | Rozporządzenie MRiRW z dnia 14.01.2009 (Dz.U.Nr 17, poz. 94) p. I ze zm. Ł Miod Zawartosc wody\nZakres (14,0 – 27)%\nMetoda refraktometryczna PN-A-77626:1988 p. 5.3.3 | Rozporzadzenie MRiRW z dnia 14.01.2009 (Dz.U.Nr 17, poz. 94) p. I ze zm. L","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(14,0 – 27)%"}],"search_en":"Honey Water content Refractometric method Range PN-A-77626:1988 p. 5.3.3 | Rozporządzenie MRiRW z dnia 14.01.2009 (Dz.U.Nr 17, poz. 94) p. I ze zm. Ł","technique_en":"Refractometric method","test_object_en":"Honey","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(14,0 – 27)%"}],"search_zh":"蜂蜜 水分含量 折射法 范围 PN-A-77626:1988 p. 5.3.3 | Rozporządzenie MRiRW z dnia 14.01.2009 (Dz.U.Nr 17, poz. 94) p. I ze zm. Ł","technique_zh":"折射法","test_object_zh":"蜂蜜"},{"_id":"6a82c6ff884ede9a1b2c2979","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Miód","methodology":"Ekstrakt","parameters":[{"name":"Zakres","range":"(71,6 – 84,4)%"}],"technique":"Metoda refraktometryczna","techniques":["Metoda refraktometryczna"],"computed":[],"activity":"Ekstrakt\nZakres (71,6 – 84,4)%\nMetoda refraktometryczna","reference":"Ł","norm_bases":["Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Miód Ekstrakt\nZakres (71,6 – 84,4)%\nMetoda refraktometryczna Ł Miod Ekstrakt\nZakres (71,6 – 84,4)%\nMetoda refraktometryczna L","categories":["other"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Extract","parameters_en":[{"name":"Range","range":"(71,6 – 84,4)%"}],"search_en":"Honey Extract Refractometric method Range Ł","technique_en":"Refractometric method","test_object_en":"Honey","parameters_zh":[{"name":"范围","range":"(71,6 – 84,4)%"}],"search_zh":"蜂蜜 浸出物 折射法 范围 Ł","technique_zh":"折射法","test_object_zh":"蜂蜜","methodology_zh":"浸出物"},{"_id":"6a82c6ff884ede9a1b2c297a","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Miód","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(15 – 1500) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (15 – 1500) μS/cm\nMetoda konduktometryczna","reference":"PN-A-77626:1988 p. 5.3.10 Ł","norm_bases":["PN-A-77626:1988 p. 5.3.10 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Miód Przewodność elektryczna właściwa\nZakres (15 – 1500) μS/cm\nMetoda konduktometryczna PN-A-77626:1988 p. 5.3.10 Ł Miod Przewodnosc elektryczna wlasciwa\nZakres (15 – 1500) μS/cm\nMetoda konduktometryczna PN-A-77626:1988 p. 5.3.10 L","categories":["other"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(15 – 1500) μS/cm"}],"search_en":"Honey Electrical conductivity Conductometric method Range PN-A-77626:1988 p. 5.3.10 Ł","technique_en":"Conductometric method","test_object_en":"Honey","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(15 – 1500) μS/cm"}],"search_zh":"蜂蜜 电导率 电导法 范围 PN-A-77626:1988 p. 5.3.10 Ł","technique_zh":"电导法","test_object_zh":"蜂蜜"},{"_id":"6a82c6ff884ede9a1b2c297b","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Miód","methodology":"Zanieczyszczenia mechaniczne","parameters":[{"name":"Zakres","range":"(0,015 – 0,15)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zanieczyszczenia mechaniczne\nZakres (0,015 – 0,15)%\nMetoda wagowa","reference":"PN-A-77626:1988 p. 5.3.11 Ł","norm_bases":["PN-A-77626:1988 p. 5.3.11 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Miód Zanieczyszczenia mechaniczne\nZakres (0,015 – 0,15)%\nMetoda wagowa PN-A-77626:1988 p. 5.3.11 Ł Miod Zanieczyszczenia mechaniczne\nZakres (0,015 – 0,15)%\nMetoda wagowa PN-A-77626:1988 p. 5.3.11 L","categories":["other"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mechanical impurities","parameters_en":[{"name":"Range","range":"(0,015 – 0,15)%"}],"search_en":"Honey Mechanical impurities Gravimetric method Range PN-A-77626:1988 p. 5.3.11 Ł","technique_en":"Gravimetric method","test_object_en":"Honey","parameters_zh":[{"name":"范围","range":"(0,015 – 0,15)%"}],"search_zh":"蜂蜜 重量法 范围 PN-A-77626:1988 p. 5.3.11 Ł","technique_zh":"重量法","test_object_zh":"蜂蜜"},{"_id":"6a82c6ff884ede9a1b2c297c","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Miód","methodology":"Wolne kwasy","parameters":[{"name":"Zakres","range":"(5,0 – 60) mval/kg"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Wolne kwasy\nZakres (5,0 – 60) mval/kg\nMetoda miareczkowania potencjometrycznego","reference":"Rozporządzenie MRiRW z dnia 14.01.2009 (Dz.U.Nr 17, poz. 94) p. VIII ze zm. Ł","norm_bases":["Rozporządzenie MRiRW z dnia 14.01.2009 (Dz.U.Nr 17, poz. 94) p. VIII ze zm. Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Miód Wolne kwasy\nZakres (5,0 – 60) mval/kg\nMetoda miareczkowania potencjometrycznego Rozporządzenie MRiRW z dnia 14.01.2009 (Dz.U.Nr 17, poz. 94) p. VIII ze zm. Ł Miod Wolne kwasy\nZakres (5,0 – 60) mval/kg\nMetoda miareczkowania potencjometrycznego Rozporzadzenie MRiRW z dnia 14.01.2009 (Dz.U.Nr 17, poz. 94) p. VIII ze zm. L","categories":["other"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free acids","parameters_en":[{"name":"Range","range":"(5,0 – 60) mval/kg"}],"search_en":"Honey Free acids Potentiometric titration method Range Rozporządzenie MRiRW z dnia 14.01.2009 (Dz.U.Nr 17, poz. 94) p. VIII ze zm. Ł","technique_en":"Potentiometric titration method","test_object_en":"Honey","parameters_zh":[{"name":"范围","range":"(5,0 – 60) mval/kg"}],"search_zh":"蜂蜜 电位滴定法 范围 Rozporządzenie MRiRW z dnia 14.01.2009 (Dz.U.Nr 17, poz. 94) p. VIII ze zm. Ł","technique_zh":"电位滴定法","test_object_zh":"蜂蜜"},{"_id":"6a82c6ff884ede9a1b2c297d","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Miód","methodology":"Zawartość proliny","parameters":[{"name":"Zakres","range":"(5,0 – 100) mg/100 g"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość proliny\nZakres (5,0 – 100) mg/100 g\nMetoda spektrofotometryczna","reference":"PN-A-77626:1988 p. 5.3.9 | Rozporządzenie MRiRW z dnia 14.01.2009 (Dz.U.Nr 17, poz. 94) p. V ze zm. Ł","norm_bases":["PN-A-77626:1988 p. 5.3.9","Rozporządzenie MRiRW z dnia 14.01.2009 (Dz.U.Nr 17, poz. 94) p. V ze zm. Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Miód Zawartość proliny\nZakres (5,0 – 100) mg/100 g\nMetoda spektrofotometryczna PN-A-77626:1988 p. 5.3.9 | Rozporządzenie MRiRW z dnia 14.01.2009 (Dz.U.Nr 17, poz. 94) p. V ze zm. Ł Miod Zawartosc proliny\nZakres (5,0 – 100) mg/100 g\nMetoda spektrofotometryczna PN-A-77626:1988 p. 5.3.9 | Rozporzadzenie MRiRW z dnia 14.01.2009 (Dz.U.Nr 17, poz. 94) p. V ze zm. L","categories":["other"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Proline content","parameters_en":[{"name":"Range","range":"(5,0 – 100) mg/100 g"}],"search_en":"Honey Proline content Spectrophotometric method Range PN-A-77626:1988 p. 5.3.9 | Rozporządzenie MRiRW z dnia 14.01.2009 (Dz.U.Nr 17, poz. 94) p. V ze zm. Ł","technique_en":"Spectrophotometric method","test_object_en":"Honey","parameters_zh":[{"name":"范围","range":"(5,0 – 100) mg/100 g"}],"search_zh":"蜂蜜 脯氨酸含量 分光光度法 范围 PN-A-77626:1988 p. 5.3.9 | Rozporządzenie MRiRW z dnia 14.01.2009 (Dz.U.Nr 17, poz. 94) p. V ze zm. Ł","technique_zh":"分光光度法","test_object_zh":"蜂蜜","methodology_zh":"脯氨酸含量"},{"_id":"6a82c6ff884ede9a1b2c297e","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Miód","methodology":"Liczba diastazowa","parameters":[{"name":"Zakres","range":"(1,0 - 20) Schade"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Liczba diastazowa\nZakres (1,0 - 20) Schade\nMetoda spektrofotometryczna","reference":"Rozporządzenie MRiRW z dnia 14.01.2009 (Dz.U.Nr 17, poz. 94) p. IX ze zm. Ł","norm_bases":["Rozporządzenie MRiRW z dnia 14.01.2009 (Dz.U.Nr 17, poz. 94) p. IX ze zm. Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Miód Liczba diastazowa\nZakres (1,0 - 20) Schade\nMetoda spektrofotometryczna Rozporządzenie MRiRW z dnia 14.01.2009 (Dz.U.Nr 17, poz. 94) p. IX ze zm. Ł Miod Liczba diastazowa\nZakres (1,0 - 20) Schade\nMetoda spektrofotometryczna Rozporzadzenie MRiRW z dnia 14.01.2009 (Dz.U.Nr 17, poz. 94) p. IX ze zm. L","categories":["other"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Diastase number","parameters_en":[{"name":"Range","range":"(1,0 - 20) Schade"}],"search_en":"Honey Diastase number Spectrophotometric method Range Rozporządzenie MRiRW z dnia 14.01.2009 (Dz.U.Nr 17, poz. 94) p. IX ze zm. Ł","technique_en":"Spectrophotometric method","test_object_en":"Honey","parameters_zh":[{"name":"范围","range":"(1,0 - 20) Schade"}],"search_zh":"蜂蜜 淀粉酶值 分光光度法 范围 Rozporządzenie MRiRW z dnia 14.01.2009 (Dz.U.Nr 17, poz. 94) p. IX ze zm. Ł","technique_zh":"分光光度法","test_object_zh":"蜂蜜","methodology_zh":"淀粉酶值"},{"_id":"6a82c6ff884ede9a1b2c297f","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Oleje, tłuszcze zwierzęce i roślinne","methodology":"Liczba jodowa","parameters":[{"name":"Zakres","range":"(3 – 200) g/100 g"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba jodowa\nZakres (3 – 200) g/100 g\nMetoda miareczkowa","reference":"PN-EN ISO 3961:2025-07 Ł","norm_bases":["PN-EN ISO 3961:2025-07 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oleje, tłuszcze zwierzęce i roślinne Liczba jodowa\nZakres (3 – 200) g/100 g\nMetoda miareczkowa PN-EN ISO 3961:2025-07 Ł Oleje, tluszcze zwierzece i roslinne Liczba jodowa\nZakres (3 – 200) g/100 g\nMetoda miareczkowa PN-EN ISO 3961:2025-07 L","categories":["food","petro"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Iodine value","parameters_en":[{"name":"Range","range":"(3 – 200) g/100 g"}],"search_en":"Oils, animal and vegetable fats Iodine value Titrimetric method Range PN-EN ISO 3961:2025-07 Ł","technique_en":"Titrimetric method","test_object_en":"Oils, animal and vegetable fats","parameters_zh":[{"name":"范围","range":"(3 – 200) g/100 g"}],"search_zh":"食用油、动植物油脂 碘值 滴定法 范围 PN-EN ISO 3961:2025-07 Ł","technique_zh":"滴定法","methodology_zh":"碘值","test_object_zh":"食用油、动植物油脂"},{"_id":"6a82c6ff884ede9a1b2c2980","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Ocet","methodology":"Kwasowość (moc)","parameters":[{"name":"Zakres","range":"(50 – 200) g/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość (moc)\nZakres (50 – 200) g/l\nMetoda miareczkowa","reference":"PN-A-79733:1996 Ł","norm_bases":["PN-A-79733:1996 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ocet Kwasowość (moc)\nZakres (50 – 200) g/l\nMetoda miareczkowa PN-A-79733:1996 Ł Ocet Kwasowosc (moc)\nZakres (50 – 200) g/l\nMetoda miareczkowa PN-A-79733:1996 L","categories":["other"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acidity (strength)","parameters_en":[{"name":"Range","range":"(50 – 200) g/l"}],"search_en":"Vinegar Acidity (strength) Titrimetric method Range PN-A-79733:1996 Ł","technique_en":"Titrimetric method","test_object_en":"Vinegar","parameters_zh":[{"name":"范围","range":"(50 – 200) g/l"}],"search_zh":"食醋 滴定法 范围 PN-A-79733:1996 Ł","technique_zh":"滴定法","test_object_zh":"食醋"},{"_id":"6a82c6ff884ede9a1b2c2981","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Mleko i przetwory mleczne, Koncentraty spożywcze, Owoce i warzywa, Przetwory owocowe i warzywne, Ryby i przetwory rybne, Wyroby cukiernicze, Zboża i przetwory zbożowe, Wyroby garmażeryjne, Napoje bezalkoholowe, Napoje alkoholowe, Kawa, Herbata, Zioła i przetwory zielarskie, Dodatki do żywności, Suplementy diety, Racje żywnościowe, Mięso i przetwory mięsne, Pasze, Jaja i przetwory jajeczne, Nasiona roślin oleistych, Oleje, tłuszcze zwierzęce i roślinne","methodology":"Masa","parameters":[{"name":"Zakres","range":"(0,100 – 3500) g"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Masa\nZakres (0,100 – 3500) g\nMetoda wagowa","reference":"PB-78/LF wyd. 5 z dnia 09.06.2025 Ł","norm_bases":["PB-78/LF wyd. 5 z dnia 09.06.2025 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko i przetwory mleczne, Koncentraty spożywcze, Owoce i warzywa, Przetwory owocowe i warzywne, Ryby i przetwory rybne, Wyroby cukiernicze, Zboża i przetwory zbożowe, Wyroby garmażeryjne, Napoje bezalkoholowe, Napoje alkoholowe, Kawa, Herbata, Zioła i przetwory zielarskie, Dodatki do żywności, Suplementy diety, Racje żywnościowe, Mięso i przetwory mięsne, Pasze, Jaja i przetwory jajeczne, Nasiona roślin oleistych, Oleje, tłuszcze zwierzęce i roślinne Masa\nZakres (0,100 – 3500) g\nMetoda wagowa PB-78/LF wyd. 5 z dnia 09.06.2025 Ł Mleko i przetwory mleczne, Koncentraty spozywcze, Owoce i warzywa, Przetwory owocowe i warzywne, Ryby i przetwory rybne, Wyroby cukiernicze, Zboza i przetwory zbozowe, Wyroby garmazeryjne, Napoje bezalkoholowe, Napoje alkoholowe, Kawa, Herbata, Ziola i przetwory zielarskie, Dodatki do zywnosci, Suplementy diety, Racje zywnosciowe, Mieso i przetwory miesne, Pasze, Jaja i przetwory jajeczne, Nasiona roslin oleistych, Oleje, tluszcze zwierzece i roslinne Masa\nZakres (0,100 – 3500) g\nMetoda wagowa PB-78/LF wyd. 5 z dnia 09.06.2025 L","categories":["food","petro","pharma"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mass","parameters_en":[{"name":"Range","range":"(0,100 – 3500) g"}],"search_en":"Milk and dairy products, Food concentrates, Fruit and vegetables, Fruit and vegetable products, Fish and fish products, Confectionery products, Cereals and cereal products, Delicatessen products, Non-alcoholic beverages, Alcoholic beverages, Coffee, Tea, Herbs and herbal products, Food additives, Food supplements, Food rations, Meat and meat products, Feed, Eggs and egg products, Oilseeds, Oils, animal and vegetable fats Mass Gravimetric method Range PB-78/LF wyd. 5 z dnia 09.06.2025 Ł","technique_en":"Gravimetric method","test_object_en":"Milk and dairy products, Food concentrates, Fruit and vegetables, Fruit and vegetable products, Fish and fish products, Confectionery products, Cereals and cereal products, Delicatessen products, Non-alcoholic beverages, Alcoholic beverages, Coffee, Tea, Herbs and herbal products, Food additives, Food supplements, Food rations, Meat and meat products, Feed, Eggs and egg products, Oilseeds, Oils, animal and vegetable fats","parameters_zh":[{"name":"范围","range":"(0,100 – 3500) g"}],"search_zh":"质量 重量法 范围 PB-78/LF wyd. 5 z dnia 09.06.2025 Ł","technique_zh":"重量法","methodology_zh":"质量"},{"_id":"6a82c6ff884ede9a1b2c2982","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Dodatki do żywności, Kawa, Herbata, Mleko i przetwory mleczne, Napoje bezalkoholowe, Napoje alkoholowe, Oleje, tłuszcze zwierzęce i roślinne, Koncentraty spożywcze","methodology":"Objętość","parameters":[{"name":"Zakres","range":"(50 – 2000) ml"}],"technique":"Metoda objętościowa","techniques":["Metoda objętościowa"],"computed":[],"activity":"Objętość\nZakres (50 – 2000) ml\nMetoda objętościowa","reference":"PB-78/LF wyd. 5 z dnia 09.06.2025 Ł","norm_bases":["PB-78/LF wyd. 5 z dnia 09.06.2025 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Dodatki do żywności, Kawa, Herbata, Mleko i przetwory mleczne, Napoje bezalkoholowe, Napoje alkoholowe, Oleje, tłuszcze zwierzęce i roślinne, Koncentraty spożywcze Objętość\nZakres (50 – 2000) ml\nMetoda objętościowa PB-78/LF wyd. 5 z dnia 09.06.2025 Ł Dodatki do zywnosci, Kawa, Herbata, Mleko i przetwory mleczne, Napoje bezalkoholowe, Napoje alkoholowe, Oleje, tluszcze zwierzece i roslinne, Koncentraty spozywcze Objetosc\nZakres (50 – 2000) ml\nMetoda objetosciowa PB-78/LF wyd. 5 z dnia 09.06.2025 L","categories":["food","petro"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volume","parameters_en":[{"name":"Range","range":"(50 – 2000) ml"}],"search_en":"Food additives, Coffee, Tea, Milk and dairy products, Non-alcoholic beverages, Alcoholic beverages, Oils, animal and vegetable fats, Food concentrates Volume Volumetric method Range PB-78/LF wyd. 5 z dnia 09.06.2025 Ł","technique_en":"Volumetric method","test_object_en":"Food additives, Coffee, Tea, Milk and dairy products, Non-alcoholic beverages, Alcoholic beverages, Oils, animal and vegetable fats, Food concentrates","parameters_zh":[{"name":"范围","range":"(50 – 2000) ml"}],"search_zh":"体积 容量法 范围 PB-78/LF wyd. 5 z dnia 09.06.2025 Ł","technique_zh":"容量法","methodology_zh":"体积"},{"_id":"6a82c6ff884ede9a1b2c2983","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Przetwory owocowe i warzywne","methodology":"Kwasowość lotna","parameters":[{"name":"Zakres","range":"(0,05 - 2,5) g/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość lotna\nZakres (0,05 - 2,5) g/l\nMetoda miareczkowa","reference":"PN-A-75101-05:1990 Ł","norm_bases":["PN-A-75101-05:1990 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory owocowe i warzywne Kwasowość lotna\nZakres (0,05 - 2,5) g/l\nMetoda miareczkowa PN-A-75101-05:1990 Ł Przetwory owocowe i warzywne Kwasowosc lotna\nZakres (0,05 - 2,5) g/l\nMetoda miareczkowa PN-A-75101-05:1990 L","categories":["other"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile acidity","parameters_en":[{"name":"Range","range":"(0,05 - 2,5) g/l"}],"search_en":"Fruit and vegetable preserves Volatile acidity Titrimetric method Range PN-A-75101-05:1990 Ł","technique_en":"Titrimetric method","test_object_en":"Fruit and vegetable preserves","parameters_zh":[{"name":"范围","range":"(0,05 - 2,5) g/l"}],"search_zh":"水果与蔬菜腌渍制品 挥发酸 滴定法 范围 PN-A-75101-05:1990 Ł","technique_zh":"滴定法","test_object_zh":"水果与蔬菜腌渍制品","methodology_zh":"挥发酸"},{"_id":"6a82c6ff884ede9a1b2c2984","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Napoje bezalkoholowe","methodology":"Kwasowość lotna","parameters":[{"name":"Zakres","range":"(0,05 – 0,5) g/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość lotna\nZakres (0,05 – 0,5) g/l\nMetoda miareczkowa","reference":"PN-A-79033:1985 Ł","norm_bases":["PN-A-79033:1985 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje bezalkoholowe Kwasowość lotna\nZakres (0,05 – 0,5) g/l\nMetoda miareczkowa PN-A-79033:1985 Ł Napoje bezalkoholowe Kwasowosc lotna\nZakres (0,05 – 0,5) g/l\nMetoda miareczkowa PN-A-79033:1985 L","categories":["food"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile acidity","parameters_en":[{"name":"Range","range":"(0,05 – 0,5) g/l"}],"search_en":"Non-alcoholic beverages Volatile acidity Titrimetric method Range PN-A-79033:1985 Ł","technique_en":"Titrimetric method","test_object_en":"Non-alcoholic beverages","parameters_zh":[{"name":"范围","range":"(0,05 – 0,5) g/l"}],"search_zh":"无酒精饮料 挥发酸 滴定法 范围 PN-A-79033:1985 Ł","technique_zh":"滴定法","test_object_zh":"无酒精饮料","methodology_zh":"挥发酸"},{"_id":"6a82c6ff884ede9a1b2c2985","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Przetwory owocowe i warzywne","methodology":"Zawartość patuliny","parameters":[{"name":"Zakres","range":"7,0 - 150 μg/kg"}],"technique":"Metoda spektrofotometryczna (ELISA)","techniques":["Metoda spektrofotometryczna (ELISA)"],"computed":[],"activity":"Zawartość patuliny\nZakres 7,0 - 150 μg/kg\nMetoda spektrofotometryczna (ELISA)","reference":"PB 331/LF wyd. 1 z dnia 14.01.2025 Ł","norm_bases":["PB 331/LF wyd. 1 z dnia 14.01.2025 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory owocowe i warzywne Zawartość patuliny\nZakres 7,0 - 150 μg/kg\nMetoda spektrofotometryczna (ELISA) PB 331/LF wyd. 1 z dnia 14.01.2025 Ł Przetwory owocowe i warzywne Zawartosc patuliny\nZakres 7,0 - 150 μg/kg\nMetoda spektrofotometryczna (ELISA) PB 331/LF wyd. 1 z dnia 14.01.2025 L","categories":["other"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Patulin content","parameters_en":[{"name":"Range","range":"7,0 - 150 μg/kg"}],"search_en":"Fruit and vegetable preserves Patulin content Spectrophotometric method (ELISA) Range PB 331/LF wyd. 1 z dnia 14.01.2025 Ł","technique_en":"Spectrophotometric method (ELISA)","test_object_en":"Fruit and vegetable preserves","parameters_zh":[{"name":"范围","range":"7,0 - 150 μg/kg"}],"search_zh":"水果与蔬菜腌渍制品 展青霉素含量 范围 PB 331/LF wyd. 1 z dnia 14.01.2025 Ł","test_object_zh":"水果与蔬菜腌渍制品","methodology_zh":"展青霉素含量"},{"_id":"6a82c6ff884ede9a1b2c2986","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Napoje bezalkoholowe, Napoje alkoholowe","methodology":"Kwasowość ogólna w przeliczeniu na odpowiedni kwas","parameters":[{"name":"Zakres","range":"(0,20 – 2,0) g/100ml"}],"technique":"Metoda miareczkowa /miareczkowania potencjometrycznego","techniques":["Metoda miareczkowa /miareczkowania potencjometrycznego"],"computed":[],"activity":"Kwasowość ogólna w przeliczeniu na odpowiedni kwas\nZakres (0,20 – 2,0) g/100ml\nMetoda miareczkowa /miareczkowania potencjometrycznego","reference":"PB-314/LF wyd. 1 z dnia 14.12.2022 Ł","norm_bases":["PB-314/LF wyd. 1 z dnia 14.12.2022 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje bezalkoholowe, Napoje alkoholowe Kwasowość ogólna w przeliczeniu na odpowiedni kwas\nZakres (0,20 – 2,0) g/100ml\nMetoda miareczkowa /miareczkowania potencjometrycznego PB-314/LF wyd. 1 z dnia 14.12.2022 Ł Napoje bezalkoholowe, Napoje alkoholowe Kwasowosc ogolna w przeliczeniu na odpowiedni kwas\nZakres (0,20 – 2,0) g/100ml\nMetoda miareczkowa /miareczkowania potencjometrycznego PB-314/LF wyd. 1 z dnia 14.12.2022 L","categories":["food"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total acidity expressed as the relevant acid","parameters_en":[{"name":"Range","range":"(0,20 – 2,0) g/100ml"}],"search_en":"Non-alcoholic beverages, Alcoholic beverages Total acidity expressed as the relevant acid Titrimetric method /potentiometric titration Range PB-314/LF wyd. 1 z dnia 14.12.2022 Ł","technique_en":"Titrimetric method /potentiometric titration","test_object_en":"Non-alcoholic beverages, Alcoholic beverages","parameters_zh":[{"name":"范围","range":"(0,20 – 2,0) g/100ml"}],"search_zh":"以相应酸计的总酸度 范围 PB-314/LF wyd. 1 z dnia 14.12.2022 Ł","methodology_zh":"以相应酸计的总酸度"},{"_id":"6a82c6ff884ede9a1b2c2987","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Owoce i warzywa, Przetwory owocowe i warzywne","methodology":"Zawartość tlenku siarki (IV)","parameters":[{"name":"Zakres","range":"(10 - 3000) mg/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość tlenku siarki (IV)\nZakres (10 - 3000) mg/kg\nMetoda miareczkowa","reference":"PB-317/LF wyd. 1 z dnia 12.12.2023 Ł","norm_bases":["PB-317/LF wyd. 1 z dnia 12.12.2023 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Owoce i warzywa, Przetwory owocowe i warzywne Zawartość tlenku siarki (IV)\nZakres (10 - 3000) mg/kg\nMetoda miareczkowa PB-317/LF wyd. 1 z dnia 12.12.2023 Ł Owoce i warzywa, Przetwory owocowe i warzywne Zawartosc tlenku siarki (IV)\nZakres (10 - 3000) mg/kg\nMetoda miareczkowa PB-317/LF wyd. 1 z dnia 12.12.2023 L","categories":["other"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur (IV) oxide content","parameters_en":[{"name":"Range","range":"(10 - 3000) mg/kg"}],"search_en":"Fruit and vegetables, Fruit and vegetable products Sulfur (IV) oxide content Titrimetric method Range PB-317/LF wyd. 1 z dnia 12.12.2023 Ł","technique_en":"Titrimetric method","test_object_en":"Fruit and vegetables, Fruit and vegetable products","parameters_zh":[{"name":"范围","range":"(10 - 3000) mg/kg"}],"search_zh":"滴定法 范围 PB-317/LF wyd. 1 z dnia 12.12.2023 Ł","technique_zh":"滴定法"},{"_id":"6a82c6ff884ede9a1b2c2988","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Ryby i przetwory rybne, Owoce morza i ich przetwory","methodology":"Zawartość lotnych zasad amonowych","parameters":[{"name":"Zakres","range":"(4,0 - 150,0) mg N/100g"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość lotnych zasad amonowych\nZakres (4,0 - 150,0) mg N/100g\nMetoda miareczkowa","reference":"PB-308/LF wyd. 1 z dnia 12.12.2023 Ł","norm_bases":["PB-308/LF wyd. 1 z dnia 12.12.2023 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ryby i przetwory rybne, Owoce morza i ich przetwory Zawartość lotnych zasad amonowych\nZakres (4,0 - 150,0) mg N/100g\nMetoda miareczkowa PB-308/LF wyd. 1 z dnia 12.12.2023 Ł Ryby i przetwory rybne, Owoce morza i ich przetwory Zawartosc lotnych zasad amonowych\nZakres (4,0 - 150,0) mg N/100g\nMetoda miareczkowa PB-308/LF wyd. 1 z dnia 12.12.2023 L","categories":["other"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile ammonium base content","parameters_en":[{"name":"Range","range":"(4,0 - 150,0) mg N/100g"}],"search_en":"Fish and fish products, Seafood and seafood products Volatile ammonium base content Titrimetric method Range PB-308/LF wyd. 1 z dnia 12.12.2023 Ł","technique_en":"Titrimetric method","test_object_en":"Fish and fish products, Seafood and seafood products","parameters_zh":[{"name":"范围","range":"(4,0 - 150,0) mg N/100g"}],"search_zh":"鱼与鱼制品、海产品及其制品 挥发性盐基氮含量 滴定法 范围 PB-308/LF wyd. 1 z dnia 12.12.2023 Ł","technique_zh":"滴定法","methodology_zh":"挥发性盐基氮含量","test_object_zh":"鱼与鱼制品、海产品及其制品"},{"_id":"6a82c6ff884ede9a1b2c2989","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Herbata, Zioła i przetwory zielarskie, Przyprawy, Suplementy diety, Miód, Produkty pszczelarskie, Przetwory owocowe i warzywne, Zboża i przetwory zbożowe","methodology":"Oznaczanie alkaloidów pirolizydynowych i tropanowych:","parameters":[{"name":"echimidyna"},{"name":"N-tlenek echimidyny"},{"name":"N-tlenek echinatyny"},{"name":"erucifolina"},{"name":"N-tlenek erucifoliny"},{"name":"europina"},{"name":"N-tlenek europiny"},{"name":"heliosupina"},{"name":"N-tlenek heliosupiny"},{"name":"heliotryna"},{"name":"N-tlenek heliotryny"},{"name":"intermedyna"},{"name":"N-tlenek intermedyny (suma N-tlenku intermedyny i N-tlenku indycyny jako N-tlenek intermedyny)"},{"name":"jacobina"},{"name":"N-tlenek jacobiny"},{"name":"lasiokarpina"},{"name":"N-tlenek lasiokarpiny"},{"name":"likopsamina (suma likopsaminy, indycyny i echinatyny jako likopsamina)"},{"name":"N-tlenek likopsaminy"},{"name":"monokrotalina"},{"name":"N-tlenek monokrotaliny"},{"name":"retrorzyna (suma retrorzyny i usaraminy jako retrorzyna)"},{"name":"N-tlenek retrorzyny"},{"name":"rinderyna"},{"name":"N-tlenek rinderyny"},{"name":"senecjonina"},{"name":"N-tlenek senecjoniny (suma N-tlenku senecjoniny i N-tlenku integerryminy jako N-tlenek senecjoniny)"},{"name":"senecyfilina (suma senecyfiliny i spartioidyny jako senecyfilina)"},{"name":"N-tlenek senecyfiliny (suma N-tlenku senecyfiliny i N-tlenku spartioidyny jako N-tlenek senecyfiliny)"},{"name":"senkirkina"},{"name":"senecywernina (suma senecywerniny i integerryminy jako senecywernina)"},{"name":"N-tlenek senecywerniny"},{"name":"trichodesmina"},{"name":"N-tlenek usaraminy"},{"name":"atropina"},{"name":"skopolamina"},{"name":"Zakres","range":"(1,0 – 1000) μg/kg"},{"name":"Suma (z obliczeń)"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)"],"computed":[],"activity":"Oznaczanie alkaloidów pirolizydynowych i tropanowych:\nZakres:\nechimidyna\nN-tlenek echimidyny\nN-tlenek echinatyny\nerucifolina\nN-tlenek erucifoliny\neuropina\nN-tlenek europiny\nheliosupina\nN-tlenek heliosupiny\nheliotryna\nN-tlenek heliotryny\nintermedyna\nN-tlenek intermedyny (suma N-tlenku intermedyny i N-tlenku indycyny jako N-tlenek intermedyny)\njacobina\nN-tlenek jacobiny\nlasiokarpina\nN-tlenek lasiokarpiny\nlikopsamina (suma likopsaminy, indycyny i echinatyny jako likopsamina)\nN-tlenek likopsaminy\nmonokrotalina\nN-tlenek monokrotaliny\nretrorzyna (suma retrorzyny i usaraminy jako retrorzyna)\nN-tlenek retrorzyny\nrinderyna\nN-tlenek rinderyny\nsenecjonina\nN-tlenek senecjoniny (suma N-tlenku senecjoniny i N-tlenku integerryminy jako N-tlenek senecjoniny)\nsenecyfilina (suma senecyfiliny i spartioidyny jako senecyfilina)\nN-tlenek senecyfiliny (suma N-tlenku senecyfiliny i N-tlenku spartioidyny jako N-tlenek senecyfiliny)\nsenkirkina\nsenecywernina (suma senecywerniny i integerryminy jako senecywernina)\nN-tlenek senecywerniny\ntrichodesmina\nN-tlenek usaraminy\natropina\nskopolamina\nZakres (1,0 – 1000) μg/kg\nSuma (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)","reference":"PB-310/LF wyd. 1 z dnia 14.12.2022 Ł","norm_bases":["PB-310/LF wyd. 1 z dnia 14.12.2022 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Herbata, Zioła i przetwory zielarskie, Przyprawy, Suplementy diety, Miód, Produkty pszczelarskie, Przetwory owocowe i warzywne, Zboża i przetwory zbożowe Oznaczanie alkaloidów pirolizydynowych i tropanowych:\nZakres:\nechimidyna\nN-tlenek echimidyny\nN-tlenek echinatyny\nerucifolina\nN-tlenek erucifoliny\neuropina\nN-tlenek europiny\nheliosupina\nN-tlenek heliosupiny\nheliotryna\nN-tlenek heliotryny\nintermedyna\nN-tlenek intermedyny (suma N-tlenku intermedyny i N-tlenku indycyny jako N-tlenek intermedyny)\njacobina\nN-tlenek jacobiny\nlasiokarpina\nN-tlenek lasiokarpiny\nlikopsamina (suma likopsaminy, indycyny i echinatyny jako likopsamina)\nN-tlenek likopsaminy\nmonokrotalina\nN-tlenek monokrotaliny\nretrorzyna (suma retrorzyny i usaraminy jako retrorzyna)\nN-tlenek retrorzyny\nrinderyna\nN-tlenek rinderyny\nsenecjonina\nN-tlenek senecjoniny (suma N-tlenku senecjoniny i N-tlenku integerryminy jako N-tlenek senecjoniny)\nsenecyfilina (suma senecyfiliny i spartioidyny jako senecyfilina)\nN-tlenek senecyfiliny (suma N-tlenku senecyfiliny i N-tlenku spartioidyny jako N-tlenek senecyfiliny)\nsenkirkina\nsenecywernina (suma senecywerniny i integerryminy jako senecywernina)\nN-tlenek senecywerniny\ntrichodesmina\nN-tlenek usaraminy\natropina\nskopolamina\nZakres (1,0 – 1000) μg/kg\nSuma (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS) PB-310/LF wyd. 1 z dnia 14.12.2022 Ł Herbata, Ziola i przetwory zielarskie, Przyprawy, Suplementy diety, Miod, Produkty pszczelarskie, Przetwory owocowe i warzywne, Zboza i przetwory zbozowe Oznaczanie alkaloidow pirolizydynowych i tropanowych:\nZakres:\nechimidyna\nN-tlenek echimidyny\nN-tlenek echinatyny\nerucifolina\nN-tlenek erucifoliny\neuropina\nN-tlenek europiny\nheliosupina\nN-tlenek heliosupiny\nheliotryna\nN-tlenek heliotryny\nintermedyna\nN-tlenek intermedyny (suma N-tlenku intermedyny i N-tlenku indycyny jako N-tlenek intermedyny)\njacobina\nN-tlenek jacobiny\nlasiokarpina\nN-tlenek lasiokarpiny\nlikopsamina (suma likopsaminy, indycyny i echinatyny jako likopsamina)\nN-tlenek likopsaminy\nmonokrotalina\nN-tlenek monokrotaliny\nretrorzyna (suma retrorzyny i usaraminy jako retrorzyna)\nN-tlenek retrorzyny\nrinderyna\nN-tlenek rinderyny\nsenecjonina\nN-tlenek senecjoniny (suma N-tlenku senecjoniny i N-tlenku integerryminy jako N-tlenek senecjoniny)\nsenecyfilina (suma senecyfiliny i spartioidyny jako senecyfilina)\nN-tlenek senecyfiliny (suma N-tlenku senecyfiliny i N-tlenku spartioidyny jako N-tlenek senecyfiliny)\nsenkirkina\nsenecywernina (suma senecywerniny i integerryminy jako senecywernina)\nN-tlenek senecywerniny\ntrichodesmina\nN-tlenek usaraminy\natropina\nskopolamina\nZakres (1,0 – 1000) μg/kg\nSuma (z obliczen)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS/MS) PB-310/LF wyd. 1 z dnia 14.12.2022 L","categories":["pharma"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Determination of pyrrolizidine and tropane alkaloids:","parameters_en":[{"name":"echimidine"},{"name":"echimidine N-oxide"},{"name":"echinatine N-oxide"},{"name":"erucifoline"},{"name":"Erucifoline N-oxide"},{"name":"europine"},{"name":"europine N-oxide"},{"name":"heliosupine"},{"name":"heliosupine N-oxide"},{"name":"heliotrine"},{"name":"heliotrine N-oxide"},{"name":"intermedine"},{"name":"N-tlenek intermedyny (suma N-tlenku intermedyny i N-tlenku indycyny jako N-tlenek intermedyny)"},{"name":"jacobine"},{"name":"Jacobine N-oxide"},{"name":"lasiocarpine"},{"name":"Lasiocarpine N-oxide"},{"name":"lycopsamine (sum of lycopsamine, indicine and echinatine as lycopsamine)"},{"name":"lycopsamine N-oxide"},{"name":"monocrotaline"},{"name":"Monocrotaline N-oxide"},{"name":"retrorsine (sum of retrorsine and usaramine as retrorsine)"},{"name":"retrorsine N-oxide"},{"name":"rinderine"},{"name":"rinderine N-oxide"},{"name":"senecionine"},{"name":"N-tlenek senecjoniny (suma N-tlenku senecjoniny i N-tlenku integerryminy jako N-tlenek senecjoniny)"},{"name":"seneciphylline (sum of seneciphylline and spartioidine as seneciphylline)"},{"name":"Seneciphylline N-oxide (sum of seneciphylline N-oxide and spartioidine N-oxide as seneciphylline N-oxide)"},{"name":"senkirkine"},{"name":"senecivernine (sum of senecivernine and integerrimine as senecivernine)"},{"name":"Senecivernine N-oxide"},{"name":"trichodesmine"},{"name":"usaramine N-oxide"},{"name":"atropine"},{"name":"scopolamine"},{"name":"Range","range":"(1,0 – 1000) μg/kg"},{"name":"Sum (calculated)"}],"search_en":"Tea, Herbs and herbal products, Spices, Dietary supplements, Honey, Bee products, Fruit and vegetable products, Cereals and cereal products Determination of pyrrolizidine and tropane alkaloids: High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS/MS) echimidine echimidine N-oxide echinatine N-oxide erucifoline Erucifoline N-oxide europine europine N-oxide heliosupine heliosupine N-oxide heliotrine heliotrine N-oxide intermedine jacobine Jacobine N-oxide lasiocarpine Lasiocarpine N-oxide lycopsamine (sum of lycopsamine, indicine and echinatine as lycopsamine) lycopsamine N-oxide monocrotaline Monocrotaline N-oxide retrorsine (sum of retrorsine and usaramine as retrorsine) retrorsine N-oxide rinderine rinderine N-oxide senecionine seneciphylline (sum of seneciphylline and spartioidine as seneciphylline) Seneciphylline N-oxide (sum of seneciphylline N-oxide and spartioidine N-oxide as seneciphylline N-oxide) senkirkine senecivernine (sum of senecivernine and integerrimine as senecivernine) Senecivernine N-oxide trichodesmine usaramine N-oxide atropine scopolamine Range Sum (calculated) PB-310/LF wyd. 1 z dnia 14.12.2022 Ł","technique_en":"High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS/MS)","test_object_en":"Tea, Herbs and herbal products, Spices, Dietary supplements, Honey, Bee products, Fruit and vegetable products, Cereals and cereal products","parameters_zh":[{"name":"echimidyna"},{"name":"N-tlenek echimidyny"},{"name":"N-tlenek echinatyny"},{"name":"erucifolina"},{"name":"N-tlenek erucifoliny"},{"name":"europina"},{"name":"N-tlenek europiny"},{"name":"heliosupina"},{"name":"N-tlenek heliosupiny"},{"name":"heliotryna"},{"name":"N-tlenek heliotryny"},{"name":"intermedyna"},{"name":"N-tlenek intermedyny (suma N-tlenku intermedyny i N-tlenku indycyny jako N-tlenek intermedyny)"},{"name":"jacobina"},{"name":"N-tlenek jacobiny"},{"name":"lasiokarpina"},{"name":"N-tlenek lasiokarpiny"},{"name":"likopsamina (suma likopsaminy, indycyny i echinatyny jako likopsamina)"},{"name":"N-tlenek likopsaminy"},{"name":"monokrotalina"},{"name":"N-tlenek monokrotaliny"},{"name":"retrorzyna (suma retrorzyny i usaraminy jako retrorzyna)"},{"name":"N-tlenek retrorzyny"},{"name":"rinderyna"},{"name":"N-tlenek rinderyny"},{"name":"senecjonina"},{"name":"N-tlenek senecjoniny (suma N-tlenku senecjoniny i N-tlenku integerryminy jako N-tlenek senecjoniny)"},{"name":"senecyfilina (suma senecyfiliny i spartioidyny jako senecyfilina)"},{"name":"N-tlenek senecyfiliny (suma N-tlenku senecyfiliny i N-tlenku spartioidyny jako N-tlenek senecyfiliny)"},{"name":"senkirkina"},{"name":"senecywernina (suma senecywerniny i integerryminy jako senecywernina)"},{"name":"N-tlenek senecywerniny"},{"name":"trichodesmina"},{"name":"N-tlenek usaraminy"},{"name":"atropina"},{"name":"skopolamina"},{"name":"范围","range":"(1,0 – 1000) μg/kg"},{"name":"总量（由计算得出）"}],"search_zh":"高效液相色谱-串联质谱法（LC-MS/MS） 范围 总量（由计算得出） PB-310/LF wyd. 1 z dnia 14.12.2022 Ł","technique_zh":"高效液相色谱-串联质谱法（LC-MS/MS）"},{"_id":"6a82c6ff884ede9a1b2c298a","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Przetwory owocowe i warzywne","methodology":"Liczba formolowa","parameters":[{"name":"Zakres","range":"(1,5-50,0) mmol NaOH/100 ml"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Liczba formolowa\nZakres (1,5-50,0) mmol NaOH/100 ml\nMetoda miareczkowania potencjometrycznego","reference":"PN-EN 1133:1999 Ł","norm_bases":["PN-EN 1133:1999 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory owocowe i warzywne Liczba formolowa\nZakres (1,5-50,0) mmol NaOH/100 ml\nMetoda miareczkowania potencjometrycznego PN-EN 1133:1999 Ł Przetwory owocowe i warzywne Liczba formolowa\nZakres (1,5-50,0) mmol NaOH/100 ml\nMetoda miareczkowania potencjometrycznego PN-EN 1133:1999 L","categories":["other"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formol number","parameters_en":[{"name":"Range","range":"(1,5-50,0) mmol NaOH/100 ml"}],"search_en":"Fruit and vegetable preserves Formol number Potentiometric titration method Range PN-EN 1133:1999 Ł","technique_en":"Potentiometric titration method","test_object_en":"Fruit and vegetable preserves","parameters_zh":[{"name":"范围","range":"(1,5-50,0) mmol NaOH/100 ml"}],"search_zh":"水果与蔬菜腌渍制品 甲醛值 电位滴定法 范围 PN-EN 1133:1999 Ł","technique_zh":"电位滴定法","test_object_zh":"水果与蔬菜腌渍制品","methodology_zh":"甲醛值"},{"_id":"6a82c6ff884ede9a1b2c298b","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Suplementy diety, Przetwory owocowe i warzywne, Wyroby cukiernicze, Zboża i przetwory zbożowe, Nasiona roślin oleistych, Pasze, Dodatki do żywności, Kawa, Herbata, Kakao, Mięso i przetwory mięsne, Oleje, tłuszcze zwierzęce i roślinne","methodology":"Zawartość akryloamidu","parameters":[{"name":"Zakres","range":"(20 – 2000) μg/kg"}],"technique":"Metoda wysokosprawnej chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS/MS)","techniques":["Metoda wysokosprawnej chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS/MS)"],"computed":[],"activity":"Zawartość akryloamidu\nZakres (20 – 2000) μg/kg\nMetoda wysokosprawnej chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS/MS)","reference":"PB-312/LF wyd. 1 z dnia 10.11.2023 Ł","norm_bases":["PB-312/LF wyd. 1 z dnia 10.11.2023 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Suplementy diety, Przetwory owocowe i warzywne, Wyroby cukiernicze, Zboża i przetwory zbożowe, Nasiona roślin oleistych, Pasze, Dodatki do żywności, Kawa, Herbata, Kakao, Mięso i przetwory mięsne, Oleje, tłuszcze zwierzęce i roślinne Zawartość akryloamidu\nZakres (20 – 2000) μg/kg\nMetoda wysokosprawnej chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS/MS) PB-312/LF wyd. 1 z dnia 10.11.2023 Ł Suplementy diety, Przetwory owocowe i warzywne, Wyroby cukiernicze, Zboza i przetwory zbozowe, Nasiona roslin oleistych, Pasze, Dodatki do zywnosci, Kawa, Herbata, Kakao, Mieso i przetwory miesne, Oleje, tluszcze zwierzece i roslinne Zawartosc akryloamidu\nZakres (20 – 2000) μg/kg\nMetoda wysokosprawnej chromatografii gazowej z detekcja tandemowa spektrometria mas (GC-MS/MS) PB-312/LF wyd. 1 z dnia 10.11.2023 L","categories":["food","petro","pharma"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acrylamide content","parameters_en":[{"name":"Range","range":"(20 – 2000) μg/kg"}],"search_en":"Food supplements, Fruit and vegetable products, Confectionery products, Cereals and cereal products, Oilseeds, Feed, Food additives, Coffee, Tea, Cocoa, Meat and meat products, Oils, animal and vegetable fats Acrylamide content High-performance gas chromatography with tandem mass spectrometry detection (GC-MS/MS) Range PB-312/LF wyd. 1 z dnia 10.11.2023 Ł","technique_en":"High-performance gas chromatography with tandem mass spectrometry detection (GC-MS/MS)","test_object_en":"Food supplements, Fruit and vegetable products, Confectionery products, Cereals and cereal products, Oilseeds, Feed, Food additives, Coffee, Tea, Cocoa, Meat and meat products, Oils, animal and vegetable fats","parameters_zh":[{"name":"范围","range":"(20 – 2000) μg/kg"}],"search_zh":"丙烯酰胺含量 范围 PB-312/LF wyd. 1 z dnia 10.11.2023 Ł","methodology_zh":"丙烯酰胺含量"},{"_id":"6a82c6ff884ede9a1b2c298c","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Suplementy diety, Wyroby cukiernicze, Zboża i przetwory zbożowe, Mleko i przetwory mleczne, Dodatki do żywności","methodology":"Zawartość laktozy","parameters":[{"name":"Zakres","range":"(0,001 – 0,1) %"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)"],"computed":[],"activity":"Zawartość laktozy\nZakres (0,001 – 0,1) %\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)","reference":"PB-315/LF wyd. 1 z dnia 29.05.2023 Ł","norm_bases":["PB-315/LF wyd. 1 z dnia 29.05.2023 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Suplementy diety, Wyroby cukiernicze, Zboża i przetwory zbożowe, Mleko i przetwory mleczne, Dodatki do żywności Zawartość laktozy\nZakres (0,001 – 0,1) %\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS) PB-315/LF wyd. 1 z dnia 29.05.2023 Ł Suplementy diety, Wyroby cukiernicze, Zboza i przetwory zbozowe, Mleko i przetwory mleczne, Dodatki do zywnosci Zawartosc laktozy\nZakres (0,001 – 0,1) %\nMetoda wysokosprawnej chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS/MS) PB-315/LF wyd. 1 z dnia 29.05.2023 L","categories":["food","pharma"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Lactose content","parameters_en":[{"name":"Range","range":"(0,001 – 0,1) %"}],"search_en":"Food supplements, Confectionery products, Cereals and cereal products, Milk and milk products, Food additives Lactose content High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS/MS) Range PB-315/LF wyd. 1 z dnia 29.05.2023 Ł","technique_en":"High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS/MS)","test_object_en":"Food supplements, Confectionery products, Cereals and cereal products, Milk and milk products, Food additives","parameters_zh":[{"name":"范围","range":"(0,001 – 0,1) %"}],"search_zh":"乳糖含量 高效液相色谱-串联质谱法（LC-MS/MS） 范围 PB-315/LF wyd. 1 z dnia 29.05.2023 Ł","technique_zh":"高效液相色谱-串联质谱法（LC-MS/MS）","methodology_zh":"乳糖含量"},{"_id":"6a82c6ff884ede9a1b2c298d","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Suplementy diety, Wyroby cukiernicze, Zboża i przetwory zbożowe, Mleko i przetwory mleczne, Dodatki do żywności","methodology":"Zawartość laktozy","parameters":[{"name":"Zakres","range":"(0,01 – 0,1) %"}],"technique":"Metoda chromatografii gazowej (GC-FID)","techniques":["Metoda chromatografii gazowej (GC-FID)"],"computed":[],"activity":"Zawartość laktozy\nZakres (0,01 – 0,1) %\nMetoda chromatografii gazowej (GC-FID)","reference":"PB-335/LF wyd. 1 z dnia 12.05.2025 Ł","norm_bases":["PB-335/LF wyd. 1 z dnia 12.05.2025 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Suplementy diety, Wyroby cukiernicze, Zboża i przetwory zbożowe, Mleko i przetwory mleczne, Dodatki do żywności Zawartość laktozy\nZakres (0,01 – 0,1) %\nMetoda chromatografii gazowej (GC-FID) PB-335/LF wyd. 1 z dnia 12.05.2025 Ł Suplementy diety, Wyroby cukiernicze, Zboza i przetwory zbozowe, Mleko i przetwory mleczne, Dodatki do zywnosci Zawartosc laktozy\nZakres (0,01 – 0,1) %\nMetoda chromatografii gazowej (GC-FID) PB-335/LF wyd. 1 z dnia 12.05.2025 L","categories":["food","pharma"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Lactose content","parameters_en":[{"name":"Range","range":"(0,01 – 0,1) %"}],"search_en":"Food supplements, Confectionery products, Cereals and cereal products, Milk and milk products, Food additives Lactose content Gas chromatography method (GC-FID) Range PB-335/LF wyd. 1 z dnia 12.05.2025 Ł","technique_en":"Gas chromatography method (GC-FID)","test_object_en":"Food supplements, Confectionery products, Cereals and cereal products, Milk and milk products, Food additives","parameters_zh":[{"name":"范围","range":"(0,01 – 0,1) %"}],"search_zh":"乳糖含量 气相色谱法（GC-FID） 范围 PB-335/LF wyd. 1 z dnia 12.05.2025 Ł","methodology_zh":"乳糖含量","technique_zh":"气相色谱法（GC-FID）"},{"_id":"6a82c6ff884ede9a1b2c298e","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Miód","methodology":"Zawartość 5-hydroksymetylofurfuralu (HMF)","parameters":[{"name":"Zakres","range":"(5,0 – 250) mg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"computed":[],"activity":"Zawartość 5-hydroksymetylofurfuralu (HMF)\nZakres (5,0 – 250) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"PB-336/LF wyd. 1 z dnia 09.06.2025 Ł","norm_bases":["PB-336/LF wyd. 1 z dnia 09.06.2025 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Miód Zawartość 5-hydroksymetylofurfuralu (HMF)\nZakres (5,0 – 250) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) PB-336/LF wyd. 1 z dnia 09.06.2025 Ł Miod Zawartosc 5-hydroksymetylofurfuralu (HMF)\nZakres (5,0 – 250) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) PB-336/LF wyd. 1 z dnia 09.06.2025 L","categories":["other"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"5-hydroxymethylfurfural (HMF) content","parameters_en":[{"name":"Range","range":"(5,0 – 250) mg/kg"}],"search_en":"Honey 5-hydroxymethylfurfural (HMF) content High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Range PB-336/LF wyd. 1 z dnia 09.06.2025 Ł","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","test_object_en":"Honey","parameters_zh":[{"name":"范围","range":"(5,0 – 250) mg/kg"}],"search_zh":"蜂蜜 5-羟甲基糠醛（HMF）含量 高效液相色谱-分光光度检测法（HPLC-UV） 范围 PB-336/LF wyd. 1 z dnia 09.06.2025 Ł","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）","test_object_zh":"蜂蜜","methodology_zh":"5-羟甲基糠醛（HMF）含量"},{"_id":"6a82c6ff884ede9a1b2c298f","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Suplementy diety, Herbata, Napoje bezalkoholowe","methodology":"Zawartość melatoniny","parameters":[{"name":"Zakres","range":"(0,1 – 10000) mg/100g"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)"],"computed":[],"activity":"Zawartość melatoniny\nZakres (0,1 – 10000) mg/100g\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)","reference":"PB-329/LF wyd. 1 z dnia 10.01.2025 L","norm_bases":["PB-329/LF wyd. 1 z dnia 10.01.2025 L"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Suplementy diety, Herbata, Napoje bezalkoholowe Zawartość melatoniny\nZakres (0,1 – 10000) mg/100g\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS) PB-329/LF wyd. 1 z dnia 10.01.2025 L Suplementy diety, Herbata, Napoje bezalkoholowe Zawartosc melatoniny\nZakres (0,1 – 10000) mg/100g\nMetoda wysokosprawnej chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS/MS) PB-329/LF wyd. 1 z dnia 10.01.2025 L","categories":["food","pharma"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Melatonin content","parameters_en":[{"name":"Range","range":"(0,1 – 10000) mg/100g"}],"search_en":"Food supplements, Tea, Non-alcoholic beverages Melatonin content High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS/MS) Range PB-329/LF wyd. 1 z dnia 10.01.2025 L","technique_en":"High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS/MS)","test_object_en":"Food supplements, Tea, Non-alcoholic beverages","parameters_zh":[{"name":"范围","range":"(0,1 – 10000) mg/100g"}],"search_zh":"高效液相色谱-串联质谱法（LC-MS/MS） 范围 PB-329/LF wyd. 1 z dnia 10.01.2025 L","technique_zh":"高效液相色谱-串联质谱法（LC-MS/MS）"},{"_id":"6a82c6ff884ede9a1b2c2990","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Dodatki do żywności","methodology":"Zawartość glikozydów stewiolowych","parameters":[{"name":"Zakres","range":"(0,1 – 100) g/100g"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)"],"computed":[],"activity":"Zawartość glikozydów stewiolowych\nZakres (0,1 – 100) g/100g\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)","reference":"PB-330/LF wyd. 1 z dnia 13.01.2025 L","norm_bases":["PB-330/LF wyd. 1 z dnia 13.01.2025 L"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Dodatki do żywności Zawartość glikozydów stewiolowych\nZakres (0,1 – 100) g/100g\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS) PB-330/LF wyd. 1 z dnia 13.01.2025 L Dodatki do zywnosci Zawartosc glikozydow stewiolowych\nZakres (0,1 – 100) g/100g\nMetoda wysokosprawnej chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS/MS) PB-330/LF wyd. 1 z dnia 13.01.2025 L","categories":["food"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Steviol glycoside content","parameters_en":[{"name":"Range","range":"(0,1 – 100) g/100g"}],"search_en":"Food additives Steviol glycoside content High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS/MS) Range PB-330/LF wyd. 1 z dnia 13.01.2025 L","technique_en":"High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS/MS)","test_object_en":"Food additives","parameters_zh":[{"name":"范围","range":"(0,1 – 100) g/100g"}],"search_zh":"食品添加剂 甜菊糖苷含量 高效液相色谱-串联质谱法（LC-MS/MS） 范围 PB-330/LF wyd. 1 z dnia 13.01.2025 L","technique_zh":"高效液相色谱-串联质谱法（LC-MS/MS）","test_object_zh":"食品添加剂","methodology_zh":"甜菊糖苷含量"},{"_id":"6a82c6ff884ede9a1b2c2991","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Suplementy diety, Wyroby cukiernicze","methodology":"Zawartość glikozydów stewiolowych","parameters":[{"name":"Zakres","range":"(1,0 – 1000) mg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)"],"computed":[],"activity":"Zawartość glikozydów stewiolowych\nZakres (1,0 – 1000) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)","reference":"PB-330/LF wyd. 1 z dnia 13.01.2025 L","norm_bases":["PB-330/LF wyd. 1 z dnia 13.01.2025 L"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Suplementy diety, Wyroby cukiernicze Zawartość glikozydów stewiolowych\nZakres (1,0 – 1000) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS) PB-330/LF wyd. 1 z dnia 13.01.2025 L Suplementy diety, Wyroby cukiernicze Zawartosc glikozydow stewiolowych\nZakres (1,0 – 1000) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS/MS) PB-330/LF wyd. 1 z dnia 13.01.2025 L","categories":["food","pharma"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Steviol glycoside content","parameters_en":[{"name":"Range","range":"(1,0 – 1000) mg/kg"}],"search_en":"Food supplements, Confectionery products Steviol glycoside content High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS/MS) Range PB-330/LF wyd. 1 z dnia 13.01.2025 L","technique_en":"High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS/MS)","test_object_en":"Food supplements, Confectionery products","parameters_zh":[{"name":"范围","range":"(1,0 – 1000) mg/kg"}],"search_zh":"甜菊糖苷含量 高效液相色谱-串联质谱法（LC-MS/MS） 范围 PB-330/LF wyd. 1 z dnia 13.01.2025 L","technique_zh":"高效液相色谱-串联质谱法（LC-MS/MS）","methodology_zh":"甜菊糖苷含量"},{"_id":"6a82c6ff884ede9a1b2c2992","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Napoje bezalkoholowe","methodology":"Zawartość glikozydów stewiolowych","parameters":[{"name":"Zakres","range":"(0,1 – 100) mg/l"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)"],"computed":[],"activity":"Zawartość glikozydów stewiolowych\nZakres (0,1 – 100) mg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)","reference":"PB-330/LF wyd. 1 z dnia 13.01.2025 L","norm_bases":["PB-330/LF wyd. 1 z dnia 13.01.2025 L"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje bezalkoholowe Zawartość glikozydów stewiolowych\nZakres (0,1 – 100) mg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS) PB-330/LF wyd. 1 z dnia 13.01.2025 L Napoje bezalkoholowe Zawartosc glikozydow stewiolowych\nZakres (0,1 – 100) mg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS/MS) PB-330/LF wyd. 1 z dnia 13.01.2025 L","categories":["food"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Steviol glycoside content","parameters_en":[{"name":"Range","range":"(0,1 – 100) mg/l"}],"search_en":"Non-alcoholic beverages Steviol glycoside content High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS/MS) Range PB-330/LF wyd. 1 z dnia 13.01.2025 L","technique_en":"High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS/MS)","test_object_en":"Non-alcoholic beverages","parameters_zh":[{"name":"范围","range":"(0,1 – 100) mg/l"}],"search_zh":"无酒精饮料 甜菊糖苷含量 高效液相色谱-串联质谱法（LC-MS/MS） 范围 PB-330/LF wyd. 1 z dnia 13.01.2025 L","technique_zh":"高效液相色谱-串联质谱法（LC-MS/MS）","test_object_zh":"无酒精饮料","methodology_zh":"甜菊糖苷含量"},{"_id":"6a82c6ff884ede9a1b2c2993","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Zawartość suchej masy/wody","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość suchej masy/wody\nMetoda wagowa","reference":"Normy Procedury badawcze Ł","norm_bases":["Normy Procedury badawcze Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E Zawartość suchej masy/wody\nMetoda wagowa Normy Procedury badawcze Ł Zywnosc E, Pasze E Zawartosc suchej masy/wody\nMetoda wagowa Normy Procedury badawcze L","categories":["food","water"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter/water content","search_en":"Food E, Feed E Dry matter/water content Gravimetric method Normy Procedury badawcze Ł","technique_en":"Gravimetric method","test_object_en":"Food E, Feed E","search_zh":"食品 E、饲料 E 重量法 Normy Procedury badawcze Ł","technique_zh":"重量法","test_object_zh":"食品 E、饲料 E"},{"_id":"6a82c6ff884ede9a1b2c2994","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Zawartość tłuszczu","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość tłuszczu\nMetoda wagowa","reference":"Normy Procedury badawcze Ł","norm_bases":["Normy Procedury badawcze Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E Zawartość tłuszczu\nMetoda wagowa Normy Procedury badawcze Ł Zywnosc E, Pasze E Zawartosc tluszczu\nMetoda wagowa Normy Procedury badawcze L","categories":["food"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fat content","search_en":"Food E, Feed E Fat content Gravimetric method Normy Procedury badawcze Ł","technique_en":"Gravimetric method","test_object_en":"Food E, Feed E","methodology_zh":"脂肪含量","search_zh":"食品 E、饲料 E 脂肪含量 重量法 Normy Procedury badawcze Ł","technique_zh":"重量法","test_object_zh":"食品 E、饲料 E"},{"_id":"6a82c6ff884ede9a1b2c2995","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Zawartość błonnika pokarmowego","parameters":[],"technique":"Metoda enzymatyczno-wagowa","techniques":["Metoda enzymatyczno-wagowa"],"computed":[],"activity":"Zawartość błonnika pokarmowego\nMetoda enzymatyczno-wagowa","reference":"Procedury badawcze Ł","norm_bases":["Procedury badawcze Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E Zawartość błonnika pokarmowego\nMetoda enzymatyczno-wagowa Procedury badawcze Ł Zywnosc E, Pasze E Zawartosc blonnika pokarmowego\nMetoda enzymatyczno-wagowa Procedury badawcze L","categories":["food"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dietary fibre content","search_en":"Food E, Feed E Dietary fibre content Enzymatic-gravimetric method Procedury badawcze Ł","technique_en":"Enzymatic-gravimetric method","test_object_en":"Food E, Feed E","methodology_zh":"膳食纤维含量","search_zh":"食品 E、饲料 E 膳食纤维含量 酶-重量法 Procedury badawcze Ł","technique_zh":"酶-重量法","test_object_zh":"食品 E、饲料 E"},{"_id":"6a82c6ff884ede9a1b2c2996","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Zawartość popiołu ogólnego","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu ogólnego\nMetoda wagowa","reference":"Procedury badawcze Ł","norm_bases":["Procedury badawcze Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E Zawartość popiołu ogólnego\nMetoda wagowa Procedury badawcze Ł Zywnosc E, Pasze E Zawartosc popiolu ogolnego\nMetoda wagowa Procedury badawcze L","categories":["food"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total ash content","search_en":"Food E, Feed E Total ash content Gravimetric method Procedury badawcze Ł","technique_en":"Gravimetric method","test_object_en":"Food E, Feed E","search_zh":"食品 E、饲料 E 总灰分含量 重量法 Procedury badawcze Ł","technique_zh":"重量法","methodology_zh":"总灰分含量","test_object_zh":"食品 E、饲料 E"},{"_id":"6a82c6ff884ede9a1b2c2997","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Zawartość azotu Kjeldahla","parameters":[{"name":"Zawartość białka (z obliczeń)"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu Kjeldahla\nZawartość białka (z obliczeń)\nMetoda miareczkowa","reference":"Procedury badawcze Ł","norm_bases":["Procedury badawcze Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E Zawartość azotu Kjeldahla\nZawartość białka (z obliczeń)\nMetoda miareczkowa Procedury badawcze Ł Zywnosc E, Pasze E Zawartosc azotu Kjeldahla\nZawartosc bialka (z obliczen)\nMetoda miareczkowa Procedury badawcze L","categories":["food"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen content","parameters_en":[{"name":"Protein content (calculated)"}],"search_en":"Food E, Feed E Kjeldahl nitrogen content Titrimetric method Protein content (calculated) Procedury badawcze Ł","technique_en":"Titrimetric method","test_object_en":"Food E, Feed E","search_zh":"食品 E、饲料 E 凯氏氮含量 滴定法 蛋白质含量（计算值） Procedury badawcze Ł","technique_zh":"滴定法","methodology_zh":"凯氏氮含量","parameters_zh":[{"name":"蛋白质含量（计算值）"}],"test_object_zh":"食品 E、饲料 E"},{"_id":"6a82c6ff884ede9a1b2c2998","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Zawartość kwasów tłuszczowych","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość kwasów tłuszczowych\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Procedury badawcze Ł","norm_bases":["Procedury badawcze Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E Zawartość kwasów tłuszczowych\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Procedury badawcze Ł Zywnosc E, Pasze E Zawartosc kwasow tluszczowych\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Procedury badawcze L","categories":["food"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fatty acid content","search_en":"Food E, Feed E Fatty acid content Gas chromatography with flame ionization detection (GC-FID) Procedury badawcze Ł","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Food E, Feed E","search_zh":"食品 E、饲料 E 脂肪酸含量 气相色谱-氢火焰离子化检测法（GC-FID） Procedury badawcze Ł","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"食品 E、饲料 E","methodology_zh":"脂肪酸含量"},{"_id":"6a82c6ff884ede9a1b2c2999","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Zawartość witamin","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV), metoda chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV), metoda chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość witamin\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV), metoda chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"Normy Procedury badawcze Ł","norm_bases":["Normy Procedury badawcze Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E Zawartość witamin\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV), metoda chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) Normy Procedury badawcze Ł Zywnosc E, Pasze E Zawartosc witamin\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV), metoda chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) Normy Procedury badawcze L","categories":["food"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Vitamin content","search_en":"Food E, Feed E Vitamin content High-performance liquid chromatography with spectrophotometric detection (HPLC-UV), liquid chromatography with fluorescence detection (HPLC-FLD) Normy Procedury badawcze Ł","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV), liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Food E, Feed E","search_zh":"食品 E、饲料 E 维生素含量 Normy Procedury badawcze Ł","test_object_zh":"食品 E、饲料 E","methodology_zh":"维生素含量"},{"_id":"6a82c6ff884ede9a1b2c299a","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość soli kuchennej","parameters":[],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość soli kuchennej\nMetoda miareczkowa","reference":"Procedury badawcze Ł","norm_bases":["Procedury badawcze Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość soli kuchennej\nMetoda miareczkowa Procedury badawcze Ł Zywnosc E Zawartosc soli kuchennej\nMetoda miareczkowa Procedury badawcze L","categories":["food"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Table salt content","search_en":"Food E Table salt content Titrimetric method Procedury badawcze Ł","technique_en":"Titrimetric method","test_object_en":"Food E","search_zh":"食品 E 食盐含量 滴定法 Procedury badawcze Ł","technique_zh":"滴定法","test_object_zh":"食品 E","methodology_zh":"食盐含量"},{"_id":"6a82c6ff884ede9a1b2c299b","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E","methodology":"Wartość energetyczna, węglowodany ogółem, węglowodany przyswajalne (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość energetyczna, węglowodany ogółem, węglowodany przyswajalne (z obliczeń)","reference":"Procedury badawcze Ł","norm_bases":["Procedury badawcze Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Wartość energetyczna, węglowodany ogółem, węglowodany przyswajalne (z obliczeń) Procedury badawcze Ł Zywnosc E Wartosc energetyczna, weglowodany ogolem, weglowodany przyswajalne (z obliczen) Procedury badawcze L","categories":["food"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Energy value, total carbohydrates, available carbohydrates (calculated)","search_en":"Food E Energy value, total carbohydrates, available carbohydrates (calculated) Procedury badawcze Ł","test_object_en":"Food E","search_zh":"食品 E Procedury badawcze Ł","test_object_zh":"食品 E"},{"_id":"6a82c6ff884ede9a1b2c299c","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E","methodology":"Analiza sensoryczna, Wyróżniki jakości sensorycznej","parameters":[],"technique":"Prosty test opisowy","techniques":["Prosty test opisowy"],"computed":[],"activity":"Analiza sensoryczna, Wyróżniki jakości sensorycznej\nProsty test opisowy","reference":"Normy Procedury badawcze Ł","norm_bases":["Normy Procedury badawcze Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Analiza sensoryczna, Wyróżniki jakości sensorycznej\nProsty test opisowy Normy Procedury badawcze Ł Zywnosc E Analiza sensoryczna, Wyrozniki jakosci sensorycznej\nProsty test opisowy Normy Procedury badawcze L","categories":["food"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Food E Simple descriptive test Normy Procedury badawcze Ł","technique_en":"Simple descriptive test","test_object_en":"Food E","search_zh":"食品 E Normy Procedury badawcze Ł","test_object_zh":"食品 E"},{"_id":"6a82c6ff884ede9a1b2c299d","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Próbki środowiskowe z obszarów produkcji i obrotu żywnością E","methodology":"Alergeny","parameters":[],"technique":"Metoda spektrofotometryczna (ELISA)","techniques":["Metoda spektrofotometryczna (ELISA)"],"computed":[],"activity":"Alergeny\nMetoda spektrofotometryczna (ELISA)","reference":"Procedury badawcze Ł","norm_bases":["Procedury badawcze Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Próbki środowiskowe z obszarów produkcji i obrotu żywnością E Alergeny\nMetoda spektrofotometryczna (ELISA) Procedury badawcze Ł Zywnosc E, Probki srodowiskowe z obszarow produkcji i obrotu zywnoscia E Alergeny\nMetoda spektrofotometryczna (ELISA) Procedury badawcze L","categories":["food","environment"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Spectrophotometric method (ELISA) Procedury badawcze Ł","technique_en":"Spectrophotometric method (ELISA)"},{"_id":"6a82c6ff884ede9a1b2c299e","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda E, Żywność E","methodology":"Stężenie pierwiastków","parameters":[],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Stężenie pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"Normy Procedury badawcze Ł","norm_bases":["Normy Procedury badawcze Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Żywność E Stężenie pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) Normy Procedury badawcze Ł Woda E, Zywnosc E Stezenie pierwiastkow\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) Normy Procedury badawcze L","categories":["water","food"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","search_en":"Element concentration Inductively coupled plasma mass spectrometry (ICP-MS) Normy Procedury badawcze Ł","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","methodology_zh":"元素浓度","search_zh":"元素浓度 电感耦合等离子体质谱法（ICP-MS） Normy Procedury badawcze Ł","technique_zh":"电感耦合等离子体质谱法（ICP-MS）"},{"_id":"6a82c6ff884ede9a1b2c299f","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość soli (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość soli (z obliczeń)","reference":"Przepisy prawa Ł","norm_bases":["Przepisy prawa Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość soli (z obliczeń) Przepisy prawa Ł Zywnosc E Zawartosc soli (z obliczen) Przepisy prawa L","categories":["food"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Salt content (calculated)","search_en":"Food E Salt content (calculated) Przepisy prawa Ł","test_object_en":"Food E","search_zh":"食品 E 盐含量（由计算得出） Przepisy prawa Ł","test_object_zh":"食品 E","methodology_zh":"盐含量（由计算得出）"},{"_id":"6a82c6ff884ede9a1b2c29a0","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Pasze E","methodology":"Stężenie pierwiastków","parameters":[],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Stężenie pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"Normy Procedury badawcze Ł","norm_bases":["Normy Procedury badawcze Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Pasze E Stężenie pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) Normy Procedury badawcze Ł Pasze E Stezenie pierwiastkow\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) Normy Procedury badawcze L","categories":["food"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","search_en":"Feed E Element concentration Inductively coupled plasma mass spectrometry (ICP-MS) Normy Procedury badawcze Ł","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Feed E","methodology_zh":"元素浓度","search_zh":"饲料 E 元素浓度 电感耦合等离子体质谱法（ICP-MS） Normy Procedury badawcze Ł","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"饲料 E"},{"_id":"6a82c6ff884ede9a1b2c29a1","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Kosmetyki E, Chemia gospodarcza E","methodology":"Stężenie pierwiastków","parameters":[],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Stężenie pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"Normy Ł","norm_bases":["Normy Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Kosmetyki E, Chemia gospodarcza E Stężenie pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) Normy Ł Kosmetyki E, Chemia gospodarcza E Stezenie pierwiastkow\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) Normy L","categories":["pharma"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","search_en":"Element concentration Inductively coupled plasma mass spectrometry (ICP-MS) Normy Ł","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","methodology_zh":"元素浓度","search_zh":"元素浓度 电感耦合等离子体质谱法（ICP-MS） Normy Ł","technique_zh":"电感耦合等离子体质谱法（ICP-MS）"},{"_id":"6a82c6ff884ede9a1b2c29a2","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Wyroby farmaceutyczne E","methodology":"Stężenie pierwiastków","parameters":[],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Stężenie pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"Normy Farmakopea Polska Farmakopea Europejska Ł","norm_bases":["Normy Farmakopea Polska Farmakopea Europejska Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Wyroby farmaceutyczne E Stężenie pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) Normy Farmakopea Polska Farmakopea Europejska Ł Wyroby farmaceutyczne E Stezenie pierwiastkow\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) Normy Farmakopea Polska Farmakopea Europejska L","categories":["pharma"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","search_en":"Element concentration Inductively coupled plasma mass spectrometry (ICP-MS) Normy Farmakopea Polska Farmakopea Europejska Ł","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","methodology_zh":"元素浓度","search_zh":"元素浓度 电感耦合等离子体质谱法（ICP-MS） Normy Farmakopea Polska Farmakopea Europejska Ł","technique_zh":"电感耦合等离子体质谱法（ICP-MS）"},{"_id":"6a82c6ff884ede9a1b2c29a3","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Stężenie pierwiastków","parameters":[],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"Procedury badawcze Ł","norm_bases":["Procedury badawcze Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E Stężenie pierwiastków\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Procedury badawcze Ł Zywnosc E, Pasze E Stezenie pierwiastkow\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Procedury badawcze L","categories":["food"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","search_en":"Food E, Feed E Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) Procedury badawcze Ł","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Food E, Feed E","methodology_zh":"元素浓度","search_zh":"食品 E、饲料 E 元素浓度 电感耦合等离子体原子发射光谱法（ICP-OES） Procedury badawcze Ł","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"食品 E、饲料 E"},{"_id":"6a82c6ff884ede9a1b2c29a4","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Zawartość mykotoksyn","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LCMS/MS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LCMS/MS)"],"computed":[],"activity":"Zawartość mykotoksyn\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LCMS/MS)","reference":"Procedury badawcze Ł","norm_bases":["Procedury badawcze Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E Zawartość mykotoksyn\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LCMS/MS) Procedury badawcze Ł Zywnosc E, Pasze E Zawartosc mykotoksyn\nMetoda wysokosprawnej chromatografii cieczowej z detekcja tandemowa spektrometria mas (LCMS/MS) Procedury badawcze L","categories":["food"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mycotoxin content","search_en":"Food E, Feed E Mycotoxin content High-performance liquid chromatography with tandem mass spectrometry detection (LCMS/MS) Procedury badawcze Ł","technique_en":"High-performance liquid chromatography with tandem mass spectrometry detection (LCMS/MS)","test_object_en":"Food E, Feed E","methodology_zh":"霉菌毒素含量","search_zh":"食品 E、饲料 E 霉菌毒素含量 Procedury badawcze Ł","test_object_zh":"食品 E、饲料 E"},{"_id":"6a82c6ff884ede9a1b2c29a5","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"Procedury badawcze Ł","norm_bases":["Procedury badawcze Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) Procedury badawcze Ł Zywnosc E Zawartosc wielopierscieniowych weglowodorow aromatycznych (WWA)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) Procedury badawcze L","categories":["food"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polycyclic aromatic hydrocarbons (PAH) content","search_en":"Food E Polycyclic aromatic hydrocarbons (PAH) content High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Procedury badawcze Ł","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Food E","search_zh":"食品 E 多环芳烃（PAHs）含量 高效液相色谱-荧光检测法（HPLC-FLD） Procedury badawcze Ł","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"食品 E","methodology_zh":"多环芳烃（PAHs）含量"},{"_id":"6a82c6ff884ede9a1b2c29a6","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość azotanów i azotynów","parameters":[],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość azotanów i azotynów\nMetoda spektrofotometryczna","reference":"Procedury badawcze Ł","norm_bases":["Procedury badawcze Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość azotanów i azotynów\nMetoda spektrofotometryczna Procedury badawcze Ł Zywnosc E Zawartosc azotanow i azotynow\nMetoda spektrofotometryczna Procedury badawcze L","categories":["food"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate and nitrite content","search_en":"Food E Nitrate and nitrite content Spectrophotometric method Procedury badawcze Ł","technique_en":"Spectrophotometric method","test_object_en":"Food E","search_zh":"食品 E 硝酸盐与亚硝酸盐含量 分光光度法 Procedury badawcze Ł","technique_zh":"分光光度法","test_object_zh":"食品 E","methodology_zh":"硝酸盐与亚硝酸盐含量"},{"_id":"6a82c6ff884ede9a1b2c29a7","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Produkty rolne E, RE), Pasze dla zwierząt E","methodology":"Zawartość pozostałości środków ochrony roślin (pestycydów)","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS); Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)"],"computed":[],"activity":"Zawartość pozostałości środków ochrony roślin (pestycydów)\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS); Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","reference":"Normy Procedury badawcze Ł","norm_bases":["Normy Procedury badawcze Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"RE) – Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów rozporządzenia (UE) nr 625/2017 Parlamentu Europejskiego i Rady z dnia 15 marca 2017 r. w sprawie kontroli urzędowych i innych czynności urzędowych przeprowadzanych w celu zapewnienia stosowania prawa żywnościowego i paszowego oraz zasad dotyczących zdrowia i dobrostanu zwierząt, zdrowia roślin i środków ochrony roślin (Dz. U. UE L 95/1 z 07.04.2017, z późn. zm.), rozporządzenia Rady (WE) nr 834/2007 z dnia 28 czerwca 2007 r. w sprawie produkcji ekologicznej i znakowania produktów ekologicznych i uchylającego rozporządzenie (EWG) nr 2092/91 (Dz.U. L 189 z 20.7.2007 str.1 z późn. zm.) oraz dokumentu SANTE/11312/2021. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Produkty rolne E, RE), Pasze dla zwierząt E Zawartość pozostałości środków ochrony roślin (pestycydów)\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS); Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS) Normy Procedury badawcze Ł Zywnosc E, Produkty rolne E, RE), Pasze dla zwierzat E Zawartosc pozostalosci srodkow ochrony roslin (pestycydow)\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC-MS-MS); Metoda chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS-MS) Normy Procedury badawcze L","categories":["food"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Gas chromatography with tandem mass spectrometry detection (GC-MS-MS); Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS) Normy Procedury badawcze Ł","technique_en":"Gas chromatography with tandem mass spectrometry detection (GC-MS-MS); Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS)"},{"_id":"6a82c6ff884ede9a1b2c29a8","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Produkty rolne E, RE), Pasze dla zwierząt E, RE)","methodology":"Zawartość pozostałości środków ochrony roślin (pestycydów)","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS); Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)"],"computed":[],"activity":"Zawartość pozostałości środków ochrony roślin (pestycydów)\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS); Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","reference":"Normy Procedury badawcze L","norm_bases":["Normy Procedury badawcze L"],"lab_section":null,"lab_address":null,"regulatory_area":"RE) – Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów rozporządzenia (UE) nr 625/2017 Parlamentu Europejskiego i Rady z dnia 15 marca 2017 r. w sprawie kontroli urzędowych i innych czynności urzędowych przeprowadzanych w celu zapewnienia stosowania prawa żywnościowego i paszowego oraz zasad dotyczących zdrowia i dobrostanu zwierząt, zdrowia roślin i środków ochrony roślin (Dz. U. UE L 95/1 z 07.04.2017, z późn. zm.), rozporządzenia Rady (WE) nr 834/2007 z dnia 28 czerwca 2007 r. w sprawie produkcji ekologicznej i znakowania produktów ekologicznych i uchylającego rozporządzenie (EWG) nr 2092/91 (Dz.U. L 189 z 20.7.2007 str.1 z późn. zm.) oraz dokumentu SANTE/11312/2021. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Produkty rolne E, RE), Pasze dla zwierząt E, RE) Zawartość pozostałości środków ochrony roślin (pestycydów)\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS); Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS) Normy Procedury badawcze L Zywnosc E, Produkty rolne E, RE), Pasze dla zwierzat E, RE) Zawartosc pozostalosci srodkow ochrony roslin (pestycydow)\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC-MS-MS); Metoda chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS-MS) Normy Procedury badawcze L","categories":["food"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Gas chromatography with tandem mass spectrometry detection (GC-MS-MS); Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS) Normy Procedury badawcze L","technique_en":"Gas chromatography with tandem mass spectrometry detection (GC-MS-MS); Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS)"},{"_id":"6a82c6ff884ede9a1b2c29a9","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba E","methodology":"Zawartość pozostałości środków ochrony roślin (pestycydów)","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektometrią mas (GC-MS-MS); Metoda chromatografii cieczowej z detekcją tandemową spektometrią mas (LC-MS-MS)","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektometrią mas (GC-MS-MS)","Metoda chromatografii cieczowej z detekcją tandemową spektometrią mas (LC-MS-MS)"],"computed":[],"activity":"Zawartość pozostałości środków ochrony roślin (pestycydów)\nMetoda chromatografii gazowej z detekcją tandemową spektometrią mas (GC-MS-MS); Metoda chromatografii cieczowej z detekcją tandemową spektometrią mas (LC-MS-MS)","reference":"Normy Procedury badawcze L","norm_bases":["Normy Procedury badawcze L"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Gleba E Zawartość pozostałości środków ochrony roślin (pestycydów)\nMetoda chromatografii gazowej z detekcją tandemową spektometrią mas (GC-MS-MS); Metoda chromatografii cieczowej z detekcją tandemową spektometrią mas (LC-MS-MS) Normy Procedury badawcze L Gleba E Zawartosc pozostalosci srodkow ochrony roslin (pestycydow)\nMetoda chromatografii gazowej z detekcja tandemowa spektometria mas (GC-MS-MS); Metoda chromatografii cieczowej z detekcja tandemowa spektometria mas (LC-MS-MS) Normy Procedury badawcze L","categories":["environment"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Soil E Gas chromatography with tandem mass spectrometry detection (GC-MS-MS); Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS) Normy Procedury badawcze L","technique_en":"Gas chromatography with tandem mass spectrometry detection (GC-MS-MS); Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS)","test_object_en":"Soil E","search_zh":"土壤 E Normy Procedury badawcze L","test_object_zh":"土壤 E"},{"_id":"6a82c6ff884ede9a1b2c29aa","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość konserwantów i ich soli","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją diodową (HPLC-DAD)"],"computed":[],"activity":"Zawartość konserwantów i ich soli\nMetoda wysokosprawnej chromatografii cieczowej z detekcją diodową (HPLC-DAD)","reference":"Normy Procedury badawcze Ł","norm_bases":["Normy Procedury badawcze Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość konserwantów i ich soli\nMetoda wysokosprawnej chromatografii cieczowej z detekcją diodową (HPLC-DAD) Normy Procedury badawcze Ł Zywnosc E Zawartosc konserwantow i ich soli\nMetoda wysokosprawnej chromatografii cieczowej z detekcja diodowa (HPLC-DAD) Normy Procedury badawcze L","categories":["food"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Food E High-performance liquid chromatography with diode array detection (HPLC-DAD) Normy Procedury badawcze Ł","technique_en":"High-performance liquid chromatography with diode array detection (HPLC-DAD)","test_object_en":"Food E","search_zh":"食品 E 高效液相色谱-二极管阵列检测法（HPLC-DAD） Normy Procedury badawcze Ł","test_object_zh":"食品 E","technique_zh":"高效液相色谱-二极管阵列检测法（HPLC-DAD）"},{"_id":"6a82c6ff884ede9a1b2c29ab","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość sztucznych substancji słodzących","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją diodową (HPLC-DAD)"],"computed":[],"activity":"Zawartość sztucznych substancji słodzących\nMetoda wysokosprawnej chromatografii cieczowej z detekcją diodową (HPLC-DAD)","reference":"Normy Procedury badawcze Ł","norm_bases":["Normy Procedury badawcze Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość sztucznych substancji słodzących\nMetoda wysokosprawnej chromatografii cieczowej z detekcją diodową (HPLC-DAD) Normy Procedury badawcze Ł Zywnosc E Zawartosc sztucznych substancji slodzacych\nMetoda wysokosprawnej chromatografii cieczowej z detekcja diodowa (HPLC-DAD) Normy Procedury badawcze L","categories":["food"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of artificial sweeteners","search_en":"Food E Content of artificial sweeteners High-performance liquid chromatography with diode array detection (HPLC-DAD) Normy Procedury badawcze Ł","technique_en":"High-performance liquid chromatography with diode array detection (HPLC-DAD)","test_object_en":"Food E","search_zh":"食品 E 高效液相色谱-二极管阵列检测法（HPLC-DAD） Normy Procedury badawcze Ł","test_object_zh":"食品 E","technique_zh":"高效液相色谱-二极管阵列检测法（HPLC-DAD）"},{"_id":"6a82c6ff884ede9a1b2c29ac","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość kofeiny","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją diodową (HPLC - DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją diodową (HPLC - DAD)"],"computed":[],"activity":"Zawartość kofeiny\nMetoda wysokosprawnej chromatografii cieczowej z detekcją diodową (HPLC - DAD)","reference":"Normy Procedury badawcze Ł","norm_bases":["Normy Procedury badawcze Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość kofeiny\nMetoda wysokosprawnej chromatografii cieczowej z detekcją diodową (HPLC - DAD) Normy Procedury badawcze Ł Zywnosc E Zawartosc kofeiny\nMetoda wysokosprawnej chromatografii cieczowej z detekcja diodowa (HPLC - DAD) Normy Procedury badawcze L","categories":["food"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Caffeine content","search_en":"Food E Caffeine content High-performance liquid chromatography with diode detection (HPLC - DAD) Normy Procedury badawcze Ł","technique_en":"High-performance liquid chromatography with diode detection (HPLC - DAD)","test_object_en":"Food E","search_zh":"食品 E 咖啡因含量 Normy Procedury badawcze Ł","test_object_zh":"食品 E","methodology_zh":"咖啡因含量"},{"_id":"6a82c6ff884ede9a1b2c29ad","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość histaminy","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją diodową (HPLC-DAD)"],"computed":[],"activity":"Zawartość histaminy\nMetoda wysokosprawnej chromatografii cieczowej z detekcją diodową (HPLC-DAD)","reference":"Procedury badawcze Ł","norm_bases":["Procedury badawcze Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość histaminy\nMetoda wysokosprawnej chromatografii cieczowej z detekcją diodową (HPLC-DAD) Procedury badawcze Ł Zywnosc E Zawartosc histaminy\nMetoda wysokosprawnej chromatografii cieczowej z detekcja diodowa (HPLC-DAD) Procedury badawcze L","categories":["food"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Histamine content","search_en":"Food E Histamine content High-performance liquid chromatography with diode array detection (HPLC-DAD) Procedury badawcze Ł","technique_en":"High-performance liquid chromatography with diode array detection (HPLC-DAD)","test_object_en":"Food E","search_zh":"食品 E 组胺含量 高效液相色谱-二极管阵列检测法（HPLC-DAD） Procedury badawcze Ł","test_object_zh":"食品 E","technique_zh":"高效液相色谱-二极管阵列检测法（HPLC-DAD）","methodology_zh":"组胺含量"},{"_id":"6a82c6ff884ede9a1b2c29ae","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Zawartość cukrów","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID)"],"computed":[],"activity":"Zawartość cukrów\nMetoda wysokosprawnej chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID)","reference":"Procedury badawcze Przepisy prawa Ł","norm_bases":["Procedury badawcze Przepisy prawa Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E Zawartość cukrów\nMetoda wysokosprawnej chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID) Procedury badawcze Przepisy prawa Ł Zywnosc E, Pasze E Zawartosc cukrow\nMetoda wysokosprawnej chromatografii cieczowej z detekcja refraktometryczna (HPLC-RID) Procedury badawcze Przepisy prawa L","categories":["food"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sugar content","search_en":"Food E, Feed E Sugar content High-performance liquid chromatography with refractive index detection (HPLC-RID) Procedury badawcze Przepisy prawa Ł","technique_en":"High-performance liquid chromatography with refractive index detection (HPLC-RID)","test_object_en":"Food E, Feed E","methodology_zh":"糖含量","search_zh":"食品 E、饲料 E 糖含量 高效液相色谱-示差折光检测法（HPLC-RID） Procedury badawcze Przepisy prawa Ł","technique_zh":"高效液相色谱-示差折光检测法（HPLC-RID）","test_object_zh":"食品 E、饲料 E"},{"_id":"6a82c6ff884ede9a1b2c29af","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość fosforu dodanego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość fosforu dodanego (z obliczeń)","reference":"Procedury badawcze Ł","norm_bases":["Procedury badawcze Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość fosforu dodanego (z obliczeń) Procedury badawcze Ł Zywnosc E Zawartosc fosforu dodanego (z obliczen) Procedury badawcze L","categories":["food"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Added phosphorus content (calculated)","search_en":"Food E Added phosphorus content (calculated) Procedury badawcze Ł","test_object_en":"Food E","search_zh":"食品 E 添加磷含量（由计算得出） Procedury badawcze Ł","test_object_zh":"食品 E","methodology_zh":"添加磷含量（由计算得出）"},{"_id":"6a82c6ff884ede9a1b2c29b0","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Zawartość włókna surowego","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość włókna surowego\nMetoda wagowa","reference":"Procedury badawcze Ł","norm_bases":["Procedury badawcze Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E Zawartość włókna surowego\nMetoda wagowa Procedury badawcze Ł Zywnosc E, Pasze E Zawartosc wlokna surowego\nMetoda wagowa Procedury badawcze L","categories":["food"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Crude fibre content","search_en":"Food E, Feed E Crude fibre content Gravimetric method Procedury badawcze Ł","technique_en":"Gravimetric method","test_object_en":"Food E, Feed E","search_zh":"食品 E、饲料 E 粗纤维含量 重量法 Procedury badawcze Ł","technique_zh":"重量法","methodology_zh":"粗纤维含量","test_object_zh":"食品 E、饲料 E"},{"_id":"6a82c6ff884ede9a1b2c29b1","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość tlenku etylenu (suma tlenku etylenu i 2-chloroetanolu wyrażona jako tlenek etylenu)","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC/MS-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC/MS-MS)"],"computed":[],"activity":"Zawartość tlenku etylenu (suma tlenku etylenu i 2-chloroetanolu wyrażona jako tlenek etylenu)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC/MS-MS)","reference":"Procedury badawcze Ł","norm_bases":["Procedury badawcze Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość tlenku etylenu (suma tlenku etylenu i 2-chloroetanolu wyrażona jako tlenek etylenu)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC/MS-MS) Procedury badawcze Ł Zywnosc E Zawartosc tlenku etylenu (suma tlenku etylenu i 2-chloroetanolu wyrazona jako tlenek etylenu)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC/MS-MS) Procedury badawcze L","categories":["food"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Food E Gas chromatography with mass spectrometry detection (GC/MS-MS) Procedury badawcze Ł","technique_en":"Gas chromatography with mass spectrometry detection (GC/MS-MS)","test_object_en":"Food E","search_zh":"食品 E Procedury badawcze Ł","test_object_zh":"食品 E"},{"_id":"6a82c6ff884ede9a1b2c29b2","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość ditiokarbaminianów wyrażona jako disiarczek węgla","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC/MS-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC/MS-MS)"],"computed":[],"activity":"Zawartość ditiokarbaminianów wyrażona jako disiarczek węgla\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC/MS-MS)","reference":"Procedury badawcze Ł","norm_bases":["Procedury badawcze Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość ditiokarbaminianów wyrażona jako disiarczek węgla\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC/MS-MS) Procedury badawcze Ł Zywnosc E Zawartosc ditiokarbaminianow wyrazona jako disiarczek wegla\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC/MS-MS) Procedury badawcze L","categories":["food"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Food E Gas chromatography with mass spectrometry detection (GC/MS-MS) Procedury badawcze Ł","technique_en":"Gas chromatography with mass spectrometry detection (GC/MS-MS)","test_object_en":"Food E","search_zh":"食品 E Procedury badawcze Ł","test_object_zh":"食品 E"},{"_id":"6a82c6ff884ede9a1b2c29b3","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Zawartość popiołu nierozpuszczalnego","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu nierozpuszczalnego\nMetoda wagowa","reference":"Procedury badawcze Ł","norm_bases":["Procedury badawcze Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E Zawartość popiołu nierozpuszczalnego\nMetoda wagowa Procedury badawcze Ł Zywnosc E, Pasze E Zawartosc popiolu nierozpuszczalnego\nMetoda wagowa Procedury badawcze L","categories":["food"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Insoluble ash content","search_en":"Food E, Feed E Insoluble ash content Gravimetric method Procedury badawcze Ł","technique_en":"Gravimetric method","test_object_en":"Food E, Feed E","search_zh":"食品 E、饲料 E 不溶性灰分含量 重量法 Procedury badawcze Ł","technique_zh":"重量法","methodology_zh":"不溶性灰分含量","test_object_zh":"食品 E、饲料 E"},{"_id":"6a82c6ff884ede9a1b2c29b4","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Zawartość witamin","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)"],"computed":[],"activity":"Zawartość witamin\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)","reference":"Procedury badawcze Ł","norm_bases":["Procedury badawcze Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E Zawartość witamin\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS) Procedury badawcze Ł Zywnosc E, Pasze E Zawartosc witamin\nMetoda wysokosprawnej chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS/MS) Procedury badawcze L","categories":["food"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Vitamin content","search_en":"Food E, Feed E Vitamin content High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS/MS) Procedury badawcze Ł","technique_en":"High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS/MS)","test_object_en":"Food E, Feed E","search_zh":"食品 E、饲料 E 维生素含量 高效液相色谱-串联质谱法（LC-MS/MS） Procedury badawcze Ł","technique_zh":"高效液相色谱-串联质谱法（LC-MS/MS）","test_object_zh":"食品 E、饲料 E","methodology_zh":"维生素含量"},{"_id":"6a82c6ff884ede9a1b2c29b5","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie żelaza(II)","parameters":[{"name":"Zakres","range":"(0,010 – 50) mg/l"},{"name":"Stężenie żelaza(III) (z obliczeń)"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza(II)\nZakres:\nZakres (0,010 – 50) mg/l\nStężenie żelaza(III) (z obliczeń)\nMetoda spektrofotometryczna","reference":"PN ISO 6332:2001 | PN ISO 6332:2001/Ap1:2016-06 M","norm_bases":["PN ISO 6332:2001","PN ISO 6332:2001/Ap1:2016-06 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie żelaza(II)\nZakres:\nZakres (0,010 – 50) mg/l\nStężenie żelaza(III) (z obliczeń)\nMetoda spektrofotometryczna PN ISO 6332:2001 | PN ISO 6332:2001/Ap1:2016-06 M Woda, woda do spozycia przez ludzi Stezenie zelaza(II)\nZakres:\nZakres (0,010 – 50) mg/l\nStezenie zelaza(III) (z obliczen)\nMetoda spektrofotometryczna PN ISO 6332:2001 | PN ISO 6332:2001/Ap1:2016-06 M","categories":["water"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Iron(II) concentration","parameters_en":[{"name":"Range","range":"(0,010 – 50) mg/l"},{"name":"Iron(III) concentration (calculated)"}],"search_en":"Water, water intended for human consumption Iron(II) concentration Spectrophotometric method Range Iron(III) concentration (calculated) PN ISO 6332:2001 | PN ISO 6332:2001/Ap1:2016-06 M","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,010 – 50) mg/l"},{"name":"Stężenie żelaza(III) (z obliczeń)"}],"search_zh":"水、生活饮用水 分光光度法 范围 PN ISO 6332:2001 | PN ISO 6332:2001/Ap1:2016-06 M","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a82c6ff884ede9a1b2c29b6","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie chlorynów","parameters":[{"name":"Zakres","range":"(0,050 – 1,0) mg/l"},{"name":"Stężenie chloranów"},{"name":"Zakres","range":"(0,050 – 1,0) mg/l"},{"name":"Suma chloranów i chlorynów (z obliczeń)"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie chlorynów\nZakres:\nZakres (0,050 – 1,0) mg/l\nStężenie chloranów\nZakres (0,050 – 1,0) mg/l\nSuma chloranów i chlorynów (z obliczeń)\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-4:2022-08 M","norm_bases":["PN-EN ISO 10304-4:2022-08 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie chlorynów\nZakres:\nZakres (0,050 – 1,0) mg/l\nStężenie chloranów\nZakres (0,050 – 1,0) mg/l\nSuma chloranów i chlorynów (z obliczeń)\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-4:2022-08 M Woda, woda do spozycia przez ludzi Stezenie chlorynow\nZakres:\nZakres (0,050 – 1,0) mg/l\nStezenie chloranow\nZakres (0,050 – 1,0) mg/l\nSuma chloranow i chlorynow (z obliczen)\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-4:2022-08 M","categories":["water"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorite concentration","parameters_en":[{"name":"Range","range":"(0,050 – 1,0) mg/l"},{"name":"Chlorate concentration"},{"name":"Range","range":"(0,050 – 1,0) mg/l"},{"name":"Sum of chlorates and chlorites (calculated)"}],"search_en":"Water, water intended for human consumption Chlorite concentration Ion chromatography with conductometric detection (IC-CD) Range Chlorate concentration Range Sum of chlorates and chlorites (calculated) PN-EN ISO 10304-4:2022-08 M","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,050 – 1,0) mg/l"},{"name":"氯酸盐浓度"},{"name":"范围","range":"(0,050 – 1,0) mg/l"},{"name":"氯酸盐与亚氯酸盐总量（由计算得出）"}],"search_zh":"水、生活饮用水 亚氯酸盐浓度 离子色谱-电导检测法（IC-CD） 范围 氯酸盐浓度 范围 氯酸盐与亚氯酸盐总量（由计算得出） PN-EN ISO 10304-4:2022-08 M","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、生活饮用水","methodology_zh":"亚氯酸盐浓度"},{"_id":"6a82c6ff884ede9a1b2c29b7","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie bromków","parameters":[{"name":"Zakres","range":"(0,10 – 20) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie bromków\nZakres (0,10 – 20) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/ AC:2012 M","norm_bases":["PN-EN ISO 10304-1:2009","PN-EN ISO 10304-1:2009/ AC:2012 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie bromków\nZakres (0,10 – 20) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/ AC:2012 M Woda, woda do spozycia przez ludzi Stezenie bromkow\nZakres (0,10 – 20) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/ AC:2012 M","categories":["water"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bromide concentration","parameters_en":[{"name":"Range","range":"(0,10 – 20) mg/l"}],"search_en":"Water, water intended for human consumption Bromide concentration Ion chromatography with conductometric detection (IC-CD) Range PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/ AC:2012 M","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,10 – 20) mg/l"}],"search_zh":"水、生活饮用水 溴化物浓度 离子色谱-电导检测法（IC-CD） 范围 PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/ AC:2012 M","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、生活饮用水","methodology_zh":"溴化物浓度"},{"_id":"6a82c6ff884ede9a1b2c29b8","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie jodków","parameters":[{"name":"Zakres","range":"(0,10 – 50) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie jodków\nZakres (0,10 – 50) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-3:2001 M","norm_bases":["PN-EN ISO 10304-3:2001 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie jodków\nZakres (0,10 – 50) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-3:2001 M Woda, woda do spozycia przez ludzi Stezenie jodkow\nZakres (0,10 – 50) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-3:2001 M","categories":["water"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Iodide concentration","parameters_en":[{"name":"Range","range":"(0,10 – 50) mg/l"}],"search_en":"Water, water intended for human consumption Iodide concentration Ion chromatography with conductometric detection (IC-CD) Range PN-EN ISO 10304-3:2001 M","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,10 – 50) mg/l"}],"search_zh":"水、生活饮用水 碘化物浓度 离子色谱-电导检测法（IC-CD） 范围 PN-EN ISO 10304-3:2001 M","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、生活饮用水","methodology_zh":"碘化物浓度"},{"_id":"6a82c6ff884ede9a1b2c29b9","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie anionów","parameters":[{"name":"azotany","range":"(0,20 - 20) mg/l"},{"name":"azotyny","range":"(0,025 – 1,0) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nazotany (0,20 - 20) mg/l\nazotyny (0,025 – 1,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/ AC:2012 M","norm_bases":["PN-EN ISO 10304-1:2009","PN-EN ISO 10304-1:2009/ AC:2012 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie anionów\nZakres:\nazotany (0,20 - 20) mg/l\nazotyny (0,025 – 1,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/ AC:2012 M Woda, woda do spozycia przez ludzi Stezenie anionow\nZakres:\nazotany (0,20 - 20) mg/l\nazotyny (0,025 – 1,0) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/ AC:2012 M","categories":["water"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"nitrates","range":"(0,20 - 20) mg/l"},{"name":"nitrites","range":"(0,025 – 1,0) mg/l"}],"search_en":"Water, water intended for human consumption Anion concentrations Ion chromatography with conductometric detection (IC-CD) nitrates nitrites PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/ AC:2012 M","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, water intended for human consumption","methodology_zh":"阴离子浓度","search_zh":"水、生活饮用水 阴离子浓度 离子色谱-电导检测法（IC-CD） 硝酸盐 亚硝酸盐 PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/ AC:2012 M","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、生活饮用水","parameters_zh":[{"name":"硝酸盐","range":"(0,20 - 20) mg/l"},{"name":"亚硝酸盐","range":"(0,025 – 1,0) mg/l"}]},{"_id":"6a82c6ff884ede9a1b2c29ba","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie bromianów","parameters":[{"name":"Zakres","range":"(1,0 – 20) μg/l"}],"technique":"Metoda chromatografii jonowej z detekcją spektrofotometryczną (IC-UV/VIS)","techniques":["Metoda chromatografii jonowej z detekcją spektrofotometryczną (IC-UV/VIS)"],"computed":[],"activity":"Stężenie bromianów\nZakres (1,0 – 20) μg/l\nMetoda chromatografii jonowej z detekcją spektrofotometryczną (IC-UV/VIS)","reference":"PN-EN ISO 11206:2013-07 M","norm_bases":["PN-EN ISO 11206:2013-07 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie bromianów\nZakres (1,0 – 20) μg/l\nMetoda chromatografii jonowej z detekcją spektrofotometryczną (IC-UV/VIS) PN-EN ISO 11206:2013-07 M Woda, woda do spozycia przez ludzi Stezenie bromianow\nZakres (1,0 – 20) μg/l\nMetoda chromatografii jonowej z detekcja spektrofotometryczna (IC-UV/VIS) PN-EN ISO 11206:2013-07 M","categories":["water"],"row_index":110,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bromate concentration","parameters_en":[{"name":"Range","range":"(1,0 – 20) μg/l"}],"search_en":"Water, water intended for human consumption Bromate concentration Ion chromatography with spectrophotometric detection (IC-UV/VIS) Range PN-EN ISO 11206:2013-07 M","technique_en":"Ion chromatography with spectrophotometric detection (IC-UV/VIS)","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(1,0 – 20) μg/l"}],"search_zh":"水、生活饮用水 溴酸盐浓度 离子色谱-分光光度检测法（IC-UV/VIS） 范围 PN-EN ISO 11206:2013-07 M","test_object_zh":"水、生活饮用水","methodology_zh":"溴酸盐浓度","technique_zh":"离子色谱-分光光度检测法（IC-UV/VIS）"},{"_id":"6a82c6ff884ede9a1b2c29bb","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie akryloamidu","parameters":[{"name":"Zakres","range":"(0,050 – 5,0) μg/l"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z tandemową spektrometrią mas (LC-MS/MS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z tandemową spektrometrią mas (LC-MS/MS)"],"computed":[],"activity":"Stężenie akryloamidu\nZakres (0,050 – 5,0) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z tandemową spektrometrią mas (LC-MS/MS)","reference":"PB-148/LF wyd. 4 z dnia 14.01.2025 M","norm_bases":["PB-148/LF wyd. 4 z dnia 14.01.2025 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie akryloamidu\nZakres (0,050 – 5,0) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z tandemową spektrometrią mas (LC-MS/MS) PB-148/LF wyd. 4 z dnia 14.01.2025 M Woda, woda do spozycia przez ludzi Stezenie akryloamidu\nZakres (0,050 – 5,0) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z tandemowa spektrometria mas (LC-MS/MS) PB-148/LF wyd. 4 z dnia 14.01.2025 M","categories":["water"],"row_index":111,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acrylamide concentration","parameters_en":[{"name":"Range","range":"(0,050 – 5,0) μg/l"}],"search_en":"Water, water intended for human consumption Acrylamide concentration High-performance liquid chromatography with tandem mass spectrometry (LC-MS/MS) Range PB-148/LF wyd. 4 z dnia 14.01.2025 M","technique_en":"High-performance liquid chromatography with tandem mass spectrometry (LC-MS/MS)","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,050 – 5,0) μg/l"}],"search_zh":"水、生活饮用水 丙烯酰胺浓度 高效液相色谱-串联质谱法（LC-MS/MS） 范围 PB-148/LF wyd. 4 z dnia 14.01.2025 M","test_object_zh":"水、生活饮用水","methodology_zh":"丙烯酰胺浓度","technique_zh":"高效液相色谱-串联质谱法（LC-MS/MS）"},{"_id":"6a82c6ff884ede9a1b2c29bc","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie epichlorohydryny","parameters":[{"name":"Zakres","range":"(0,025 – 1,0) μg/l"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)"],"computed":[],"activity":"Stężenie epichlorohydryny\nZakres (0,025 – 1,0) μg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","reference":"PB-190/LF wyd. 4 z dnia 20.01.2022 M","norm_bases":["PB-190/LF wyd. 4 z dnia 20.01.2022 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie epichlorohydryny\nZakres (0,025 – 1,0) μg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) PB-190/LF wyd. 4 z dnia 20.01.2022 M Woda, woda do spozycia przez ludzi Stezenie epichlorohydryny\nZakres (0,025 – 1,0) μg/l\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) PB-190/LF wyd. 4 z dnia 20.01.2022 M","categories":["water"],"row_index":112,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Epichlorohydrin concentration","parameters_en":[{"name":"Range","range":"(0,025 – 1,0) μg/l"}],"search_en":"Water, water intended for human consumption Epichlorohydrin concentration Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) Range PB-190/LF wyd. 4 z dnia 20.01.2022 M","technique_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,025 – 1,0) μg/l"}],"search_zh":"水、生活饮用水 环氧氯丙烷浓度 顶空气相色谱-质谱法（HS-GC-MS） 范围 PB-190/LF wyd. 4 z dnia 20.01.2022 M","test_object_zh":"水、生活饮用水","technique_zh":"顶空气相色谱-质谱法（HS-GC-MS）","methodology_zh":"环氧氯丙烷浓度"},{"_id":"6a82c6ff884ede9a1b2c29bd","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda ultraczysta","methodology":"Stężenie ogólnego węgla organicznego (OWO)","parameters":[{"name":"Zakres","range":"(0,10 – 20,0) mg/l"}],"technique":"Metoda utleniania z detekcją NDIR","techniques":["Metoda utleniania z detekcją NDIR"],"computed":[],"activity":"Stężenie ogólnego węgla organicznego (OWO)\nZakres (0,10 – 20,0) mg/l\nMetoda utleniania z detekcją NDIR","reference":"PN-EN 1484:1999 M","norm_bases":["PN-EN 1484:1999 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda ultraczysta Stężenie ogólnego węgla organicznego (OWO)\nZakres (0,10 – 20,0) mg/l\nMetoda utleniania z detekcją NDIR PN-EN 1484:1999 M Woda ultraczysta Stezenie ogolnego wegla organicznego (OWO)\nZakres (0,10 – 20,0) mg/l\nMetoda utleniania z detekcja NDIR PN-EN 1484:1999 M","categories":["water"],"row_index":113,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon concentration (TOC)","parameters_en":[{"name":"Range","range":"(0,10 – 20,0) mg/l"}],"search_en":"Ultrapure water Total organic carbon concentration (TOC) Oxidation method with NDIR detection Range PN-EN 1484:1999 M","technique_en":"Oxidation method with NDIR detection","test_object_en":"Ultrapure water","parameters_zh":[{"name":"范围","range":"(0,10 – 20,0) mg/l"}],"search_zh":"总有机碳浓度（TOC） 范围 PN-EN 1484:1999 M","methodology_zh":"总有机碳浓度（TOC）"},{"_id":"6a82c6ff884ede9a1b2c29be","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 – 500) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (5 – 500) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 pkt 6 M","norm_bases":["PN-EN ISO 7887:2012 pkt 6 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Barwa\nZakres (5 – 500) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 pkt 6 M Woda, woda do spozycia przez ludzi, scieki Barwa\nZakres (5 – 500) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 pkt 6 M","categories":["water"],"row_index":114,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 – 500) mg/l Pt"}],"search_en":"Water, water intended for human consumption, wastewater Colour Spectrophotometric method Range PN-EN ISO 7887:2012 pkt 6 M","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 500) mg/l Pt"}],"search_zh":"水、生活饮用水、污水 色度 分光光度法 范围 PN-EN ISO 7887:2012 pkt 6 M","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29bf","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Barwa pozorna","parameters":[{"name":"Zakres","range":"(5 - 500) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa pozorna\nZakres (5 - 500) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 pkt 6 M","norm_bases":["PN-EN ISO 7887:2012 pkt 6 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Barwa pozorna\nZakres (5 - 500) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 pkt 6 M Woda, woda do spozycia przez ludzi, scieki Barwa pozorna\nZakres (5 - 500) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 pkt 6 M","categories":["water"],"row_index":115,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Apparent colour","parameters_en":[{"name":"Range","range":"(5 - 500) mg/l Pt"}],"search_en":"Water, water intended for human consumption, wastewater Apparent colour Spectrophotometric method Range PN-EN ISO 7887:2012 pkt 6 M","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(5 - 500) mg/l Pt"}],"search_zh":"水、生活饮用水、污水 分光光度法 范围 PN-EN ISO 7887:2012 pkt 6 M","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29c0","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 – 750) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 – 750) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09 M","norm_bases":["PN-EN ISO 7027-1:2016-09 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Mętność\nZakres (0,10 – 750) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 M Woda, woda do spozycia przez ludzi, scieki Metnosc\nZakres (0,10 – 750) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 M","categories":["water"],"row_index":116,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,10 – 750) NTU"}],"search_en":"Water, water intended for human consumption, wastewater Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09 M","technique_en":"Nephelometric method","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 – 750) NTU"}],"search_zh":"水、生活饮用水、污水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09 M","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29c1","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Twardość ogólna (sumaryczna zawartość wapnia i magnezu) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Twardość ogólna (sumaryczna zawartość wapnia i magnezu) (z obliczeń)","reference":"PN-EN ISO 17294-2:2024-04 M","norm_bases":["PN-EN ISO 17294-2:2024-04 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Twardość ogólna (sumaryczna zawartość wapnia i magnezu) (z obliczeń) PN-EN ISO 17294-2:2024-04 M Woda, woda do spozycia przez ludzi Twardosc ogolna (sumaryczna zawartosc wapnia i magnezu) (z obliczen) PN-EN ISO 17294-2:2024-04 M","categories":["water"],"row_index":117,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total hardness (total calcium and magnesium content) (calculated)","search_en":"Water, water intended for human consumption Total hardness (total calcium and magnesium content) (calculated) PN-EN ISO 17294-2:2024-04 M","test_object_en":"Water, water intended for human consumption","search_zh":"水、生活饮用水 PN-EN ISO 17294-2:2024-04 M","test_object_zh":"水、生活饮用水"},{"_id":"6a82c6ff884ede9a1b2c29c2","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba progowa smaku (TFN)","parameters":[{"name":"Zakres","range":"(1-8)"}],"technique":"Metoda pełna, parzysta, wybór niewymuszony","techniques":["Metoda pełna, parzysta, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa smaku (TFN)\nZakres (1-8)\nMetoda pełna, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006 M","norm_bases":["PN-EN 1622:2006 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba progowa smaku (TFN)\nZakres (1-8)\nMetoda pełna, parzysta, wybór niewymuszony PN-EN 1622:2006 M Woda do spozycia przez ludzi Liczba progowa smaku (TFN)\nZakres (1-8)\nMetoda pelna, parzysta, wybor niewymuszony PN-EN 1622:2006 M","categories":["water"],"row_index":118,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Taste threshold number (TFN)","parameters_en":[{"name":"Range","range":"(1-8)"}],"search_en":"Water intended for human consumption Taste threshold number (TFN) Full paired method, non-forced choice Range PN-EN 1622:2006 M","technique_en":"Full paired method, non-forced choice","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(1-8)"}],"search_zh":"生活饮用水 味阈值（TFN） 完全法、成对法、非强制选择 范围 PN-EN 1622:2006 M","test_object_zh":"生活饮用水","methodology_zh":"味阈值（TFN）","technique_zh":"完全法、成对法、非强制选择"},{"_id":"6a82c6ff884ede9a1b2c29c3","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba progowa zapachu (TON)","parameters":[{"name":"Zakres","range":"(1-8)"}],"technique":"Metoda pełna, parzysta, wybór niewymuszony","techniques":["Metoda pełna, parzysta, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa zapachu (TON)\nZakres (1-8)\nMetoda pełna, parzysta, wybór niewymuszony","reference":"M","norm_bases":["M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba progowa zapachu (TON)\nZakres (1-8)\nMetoda pełna, parzysta, wybór niewymuszony M Woda do spozycia przez ludzi Liczba progowa zapachu (TON)\nZakres (1-8)\nMetoda pelna, parzysta, wybor niewymuszony M","categories":["water"],"row_index":119,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Odour threshold number (TON)","parameters_en":[{"name":"Range","range":"(1-8)"}],"search_en":"Water intended for human consumption Odour threshold number (TON) Full paired method, non-forced choice Range M","technique_en":"Full paired method, non-forced choice","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(1-8)"}],"search_zh":"生活饮用水 嗅阈值（TON） 完全法、成对法、非强制选择 范围 M","test_object_zh":"生活饮用水","methodology_zh":"嗅阈值（TON）","technique_zh":"完全法、成对法、非强制选择"},{"_id":"6a82c6ff884ede9a1b2c29c4","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesiny łatwoopadające","parameters":[{"name":"Zakres","range":"(0,2 - 100) ml/l"}],"technique":"Metoda objętościowa","techniques":["Metoda objętościowa"],"computed":[],"activity":"Zawiesiny łatwoopadające\nZakres (0,2 - 100) ml/l\nMetoda objętościowa","reference":"PN-72/C-04559/03 M","norm_bases":["PN-72/C-04559/03 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesiny łatwoopadające\nZakres (0,2 - 100) ml/l\nMetoda objętościowa PN-72/C-04559/03 M Woda, scieki Zawiesiny latwoopadajace\nZakres (0,2 - 100) ml/l\nMetoda objetosciowa PN-72/C-04559/03 M","categories":["water"],"row_index":120,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Settleable solids","parameters_en":[{"name":"Range","range":"(0,2 - 100) ml/l"}],"search_en":"Water, wastewater Settleable solids Volumetric method Range PN-72/C-04559/03 M","technique_en":"Volumetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,2 - 100) ml/l"}],"search_zh":"水、废水 易沉降悬浮物 容量法 范围 PN-72/C-04559/03 M","test_object_zh":"水、废水","technique_zh":"容量法","methodology_zh":"易沉降悬浮物"},{"_id":"6a82c6ff884ede9a1b2c29c5","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Substancje rozpuszczone ogólne","parameters":[{"name":"Zakres","range":"(50 – 23 000) mg/l"},{"name":"Substancje rozpuszczalne mineralne"},{"name":"Zakres","range":"(10 – 3000) mg/l"},{"name":"Substancje rozpuszczone lotne (z obliczeń)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje rozpuszczone ogólne\nZakres:\nZakres (50 – 23 000) mg/l\nSubstancje rozpuszczalne mineralne\nZakres (10 – 3000) mg/l\nSubstancje rozpuszczone lotne (z obliczeń)\nMetoda wagowa","reference":"PB-338/LF wyd. 1 z dnia 7.01.2026 M","norm_bases":["PB-338/LF wyd. 1 z dnia 7.01.2026 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Substancje rozpuszczone ogólne\nZakres:\nZakres (50 – 23 000) mg/l\nSubstancje rozpuszczalne mineralne\nZakres (10 – 3000) mg/l\nSubstancje rozpuszczone lotne (z obliczeń)\nMetoda wagowa PB-338/LF wyd. 1 z dnia 7.01.2026 M Woda, woda do spozycia przez ludzi, scieki Substancje rozpuszczone ogolne\nZakres:\nZakres (50 – 23 000) mg/l\nSubstancje rozpuszczalne mineralne\nZakres (10 – 3000) mg/l\nSubstancje rozpuszczone lotne (z obliczen)\nMetoda wagowa PB-338/LF wyd. 1 z dnia 7.01.2026 M","categories":["water"],"row_index":121,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total dissolved solids","parameters_en":[{"name":"Range","range":"(50 – 23 000) mg/l"},{"name":"Substancje rozpuszczalne mineralne"},{"name":"Range","range":"(10 – 3000) mg/l"},{"name":"Volatile dissolved solids (calculated)"}],"search_en":"Water, water intended for human consumption, wastewater Total dissolved solids Gravimetric method Range Range Volatile dissolved solids (calculated) PB-338/LF wyd. 1 z dnia 7.01.2026 M","technique_en":"Gravimetric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(50 – 23 000) mg/l"},{"name":"Substancje rozpuszczalne mineralne"},{"name":"范围","range":"(10 – 3000) mg/l"},{"name":"Substancje rozpuszczone lotne (z obliczeń)"}],"search_zh":"水、生活饮用水、污水 重量法 范围 范围 PB-338/LF wyd. 1 z dnia 7.01.2026 M","technique_zh":"重量法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29c6","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Sucha pozostałość","parameters":[{"name":"Zakres","range":"(10 – 25000) mg/l"},{"name":"Pozostałość po prażeniu"},{"name":"Zakres","range":"(10 – 16000) mg/l"},{"name":"Straty prażenia (z obliczeń)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość\nZakres:\nZakres (10 – 25000) mg/l\nPozostałość po prażeniu\nZakres (10 – 16000) mg/l\nStraty prażenia (z obliczeń)\nMetoda wagowa","reference":"PB-338/LF wyd. 1 z dnia 7.01.2026 M","norm_bases":["PB-338/LF wyd. 1 z dnia 7.01.2026 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Sucha pozostałość\nZakres:\nZakres (10 – 25000) mg/l\nPozostałość po prażeniu\nZakres (10 – 16000) mg/l\nStraty prażenia (z obliczeń)\nMetoda wagowa PB-338/LF wyd. 1 z dnia 7.01.2026 M Woda, woda do spozycia przez ludzi, scieki Sucha pozostalosc\nZakres:\nZakres (10 – 25000) mg/l\nPozostalosc po prazeniu\nZakres (10 – 16000) mg/l\nStraty prazenia (z obliczen)\nMetoda wagowa PB-338/LF wyd. 1 z dnia 7.01.2026 M","categories":["water"],"row_index":122,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry residue","parameters_en":[{"name":"Range","range":"(10 – 25000) mg/l"},{"name":"Residue on ignition"},{"name":"Range","range":"(10 – 16000) mg/l"},{"name":"Loss on ignition (calculated)"}],"search_en":"Water, water intended for human consumption, wastewater Dry residue Gravimetric method Range Residue on ignition Range Loss on ignition (calculated) PB-338/LF wyd. 1 z dnia 7.01.2026 M","technique_en":"Gravimetric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(10 – 25000) mg/l"},{"name":"灼烧残渣"},{"name":"范围","range":"(10 – 16000) mg/l"},{"name":"Straty prażenia (z obliczeń)"}],"search_zh":"水、生活饮用水、污水 干残渣 重量法 范围 灼烧残渣 范围 PB-338/LF wyd. 1 z dnia 7.01.2026 M","technique_zh":"重量法","test_object_zh":"水、生活饮用水、污水","methodology_zh":"干残渣"},{"_id":"6a82c6ff884ede9a1b2c29c7","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Mineralizacja ogólna (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Mineralizacja ogólna (z obliczeń)","reference":"PB-338/LF wyd. 1 z dnia 7.01.2026 M","norm_bases":["PB-338/LF wyd. 1 z dnia 7.01.2026 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Mineralizacja ogólna (z obliczeń) PB-338/LF wyd. 1 z dnia 7.01.2026 M Woda, woda do spozycia przez ludzi, scieki Mineralizacja ogolna (z obliczen) PB-338/LF wyd. 1 z dnia 7.01.2026 M","categories":["water"],"row_index":123,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total mineralisation (calculated)","search_en":"Water, water intended for human consumption, wastewater Total mineralisation (calculated) PB-338/LF wyd. 1 z dnia 7.01.2026 M","test_object_en":"Water, water intended for human consumption, wastewater","search_zh":"水、生活饮用水、污水 PB-338/LF wyd. 1 z dnia 7.01.2026 M","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29c8","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Indeks nadmanganianowy (chemiczne zapotrzebowanie tlenu - ChZT-Mn) / utlenialność","parameters":[{"name":"Zakres","range":"(0,50 - 500) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy (chemiczne zapotrzebowanie tlenu - ChZT-Mn) / utlenialność\nZakres (0,50 - 500) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001 M","norm_bases":["PN-EN ISO 8467:2001 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Indeks nadmanganianowy (chemiczne zapotrzebowanie tlenu - ChZT-Mn) / utlenialność\nZakres (0,50 - 500) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 M Woda, woda do spozycia przez ludzi, scieki Indeks nadmanganianowy (chemiczne zapotrzebowanie tlenu - ChZT-Mn) / utlenialnosc\nZakres (0,50 - 500) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 M","categories":["water"],"row_index":124,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index (chemical oxygen demand - COD-Mn) / oxidisability","parameters_en":[{"name":"Range","range":"(0,50 - 500) mg/l O2"}],"search_en":"Water, water intended for human consumption, wastewater Permanganate index (chemical oxygen demand - COD-Mn) / oxidisability Titrimetric method Range PN-EN ISO 8467:2001 M","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,50 - 500) mg/l O2"}],"search_zh":"水、生活饮用水、污水 滴定法 范围 PN-EN ISO 8467:2001 M","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29c9","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie formaldehydu (aldehydu mrówkowego)","parameters":[{"name":"Zakres","range":"(0,020 – 10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie formaldehydu (aldehydu mrówkowego)\nZakres (0,020 – 10) mg/l\nMetoda spektrofotometryczna","reference":"PB-117/LF wyd. 3 z dnia 26.01.2022 M","norm_bases":["PB-117/LF wyd. 3 z dnia 26.01.2022 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie formaldehydu (aldehydu mrówkowego)\nZakres (0,020 – 10) mg/l\nMetoda spektrofotometryczna PB-117/LF wyd. 3 z dnia 26.01.2022 M Woda, woda do spozycia przez ludzi, scieki Stezenie formaldehydu (aldehydu mrowkowego)\nZakres (0,020 – 10) mg/l\nMetoda spektrofotometryczna PB-117/LF wyd. 3 z dnia 26.01.2022 M","categories":["water"],"row_index":125,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde (methanal) concentration","parameters_en":[{"name":"Range","range":"(0,020 – 10) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Formaldehyde (methanal) concentration Spectrophotometric method Range PB-117/LF wyd. 3 z dnia 26.01.2022 M","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,020 – 10) mg/l"}],"search_zh":"水、生活饮用水、污水 分光光度法 范围 PB-117/LF wyd. 3 z dnia 26.01.2022 M","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29ca","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie substancji powierzchniowo czynnych anionowych (surfaktantów anionowych / detergentów anionowych)","parameters":[{"name":"Zakres","range":"(0,050 – 50) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie substancji powierzchniowo czynnych anionowych (surfaktantów anionowych / detergentów anionowych)\nZakres (0,050 – 50) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 16265:2012 M","norm_bases":["PN-EN ISO 16265:2012 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie substancji powierzchniowo czynnych anionowych (surfaktantów anionowych / detergentów anionowych)\nZakres (0,050 – 50) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 16265:2012 M Woda, woda do spozycia przez ludzi, scieki Stezenie substancji powierzchniowo czynnych anionowych (surfaktantow anionowych / detergentow anionowych)\nZakres (0,050 – 50) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 16265:2012 M","categories":["water"],"row_index":126,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of anionic surfactants (anionic surfactants / anionic detergents)","parameters_en":[{"name":"Range","range":"(0,050 – 50) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Concentration of anionic surfactants (anionic surfactants / anionic detergents) Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 16265:2012 M","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,050 – 50) mg/l"}],"search_zh":"水、生活饮用水、污水 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 16265:2012 M","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29cb","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie substancji powierzchniowo","parameters":[{"name":"czynnych niejonowych (surfaktantów niejonowych / detergentów niejonowych)"},{"name":"Zakres","range":"(0,20 – 100) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie substancji powierzchniowo\nZakres:\nczynnych niejonowych (surfaktantów niejonowych / detergentów niejonowych)\nZakres (0,20 – 100) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PB-12/LF wyd. 4 z dnia 7.01.2026 M","norm_bases":["PB-12/LF wyd. 4 z dnia 7.01.2026 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie substancji powierzchniowo\nZakres:\nczynnych niejonowych (surfaktantów niejonowych / detergentów niejonowych)\nZakres (0,20 – 100) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PB-12/LF wyd. 4 z dnia 7.01.2026 M Woda, woda do spozycia przez ludzi, scieki Stezenie substancji powierzchniowo\nZakres:\nczynnych niejonowych (surfaktantow niejonowych / detergentow niejonowych)\nZakres (0,20 – 100) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PB-12/LF wyd. 4 z dnia 7.01.2026 M","categories":["water"],"row_index":127,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of surface-active","parameters_en":[{"name":"non-ionic surface active agents (non-ionic surfactants / non-ionic detergents)"},{"name":"Range","range":"(0,20 – 100) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Concentration of surface-active Continuous flow analysis (CFA) with spectrophotometric detection non-ionic surface active agents (non-ionic surfactants / non-ionic detergents) Range PB-12/LF wyd. 4 z dnia 7.01.2026 M","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"czynnych niejonowych (surfaktantów niejonowych / detergentów niejonowych)"},{"name":"范围","range":"(0,20 – 100) mg/l"}],"search_zh":"水、生活饮用水、污水 连续流动分析（CFA）分光光度检测法 范围 PB-12/LF wyd. 4 z dnia 7.01.2026 M","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29cc","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(1 - 2000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 - 2000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12 M","norm_bases":["PN-EN ISO 5815-1:2019-12 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 - 2000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 M Woda, woda do spozycia przez ludzi, scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 - 2000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 M","categories":["water"],"row_index":128,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(1 - 2000) mg/l O2"}],"search_en":"Water, water intended for human consumption, wastewater Biochemical oxygen demand - BOD5 Optical method Range PN-EN ISO 5815-1:2019-12 M","technique_en":"Optical method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(1 - 2000) mg/l O2"}],"search_zh":"水、生活饮用水、污水 五日生化需氧量（BOD5） 光学法 范围 PN-EN ISO 5815-1:2019-12 M","technique_zh":"光学法","test_object_zh":"水、生活饮用水、污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a82c6ff884ede9a1b2c29cd","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Zawiesiny ogólne, mineralne","parameters":[{"name":"Zakres","range":"(4,0 - 5000) mg/l"},{"name":"Zawiesiny lotne (z obliczeń)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne, mineralne\nZakres:\nZakres (4,0 - 5000) mg/l\nZawiesiny lotne (z obliczeń)\nMetoda wagowa","reference":"PN-72/C-04559/02 M","norm_bases":["PN-72/C-04559/02 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Zawiesiny ogólne, mineralne\nZakres:\nZakres (4,0 - 5000) mg/l\nZawiesiny lotne (z obliczeń)\nMetoda wagowa PN-72/C-04559/02 M Woda, woda do spozycia przez ludzi, scieki Zawiesiny ogolne, mineralne\nZakres:\nZakres (4,0 - 5000) mg/l\nZawiesiny lotne (z obliczen)\nMetoda wagowa PN-72/C-04559/02 M","categories":["water"],"row_index":129,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total, mineral suspended solids","parameters_en":[{"name":"Range","range":"(4,0 - 5000) mg/l"},{"name":"Volatile suspended solids (calculated)"}],"search_en":"Water, water intended for human consumption, wastewater Total, mineral suspended solids Gravimetric method Range Volatile suspended solids (calculated) PN-72/C-04559/02 M","technique_en":"Gravimetric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(4,0 - 5000) mg/l"},{"name":"Zawiesiny lotne (z obliczeń)"}],"search_zh":"水、生活饮用水、污水 重量法 范围 PN-72/C-04559/02 M","technique_zh":"重量法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29ce","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie substancji ekstrahujących się eterem naftowym","parameters":[{"name":"Zakres","range":"(10 - 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym\nZakres (10 - 1000) mg/l\nMetoda wagowa","reference":"PB-33/LF wyd. 3 z dnia 26.01.2022 M","norm_bases":["PB-33/LF wyd. 3 z dnia 26.01.2022 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie substancji ekstrahujących się eterem naftowym\nZakres (10 - 1000) mg/l\nMetoda wagowa PB-33/LF wyd. 3 z dnia 26.01.2022 M Woda, woda do spozycia przez ludzi, scieki Stezenie substancji ekstrahujacych sie eterem naftowym\nZakres (10 - 1000) mg/l\nMetoda wagowa PB-33/LF wyd. 3 z dnia 26.01.2022 M","categories":["water"],"row_index":130,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(10 - 1000) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Concentration of substances extractable with petroleum ether Gravimetric method Range PB-33/LF wyd. 3 z dnia 26.01.2022 M","technique_en":"Gravimetric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(10 - 1000) mg/l"}],"search_zh":"水、生活饮用水、污水 石油醚可萃取物浓度 重量法 范围 PB-33/LF wyd. 3 z dnia 26.01.2022 M","technique_zh":"重量法","test_object_zh":"水、生活饮用水、污水","methodology_zh":"石油醚可萃取物浓度"},{"_id":"6a82c6ff884ede9a1b2c29cf","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie substancji ekstrahujących się chloroformem","parameters":[{"name":"Zakres","range":"(10 - 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie substancji ekstrahujących się chloroformem\nZakres (10 - 1000) mg/l\nMetoda wagowa","reference":"M","norm_bases":["M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie substancji ekstrahujących się chloroformem\nZakres (10 - 1000) mg/l\nMetoda wagowa M Woda, woda do spozycia przez ludzi, scieki Stezenie substancji ekstrahujacych sie chloroformem\nZakres (10 - 1000) mg/l\nMetoda wagowa M","categories":["water"],"row_index":131,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of substances extractable with chloroform","parameters_en":[{"name":"Range","range":"(10 - 1000) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Concentration of substances extractable with chloroform Gravimetric method Range M","technique_en":"Gravimetric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(10 - 1000) mg/l"}],"search_zh":"水、生活饮用水、污水 重量法 范围 M","technique_zh":"重量法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29d0","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10 - 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10 - 5000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002 M","norm_bases":["PN-ISO 9280:2002 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie siarczanów\nZakres (10 - 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002 M Woda, woda do spozycia przez ludzi, scieki Stezenie siarczanow\nZakres (10 - 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002 M","categories":["water"],"row_index":132,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10 - 5000) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Sulfate concentration Gravimetric method Range PN-ISO 9280:2002 M","technique_en":"Gravimetric method","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 - 5000) mg/l"}],"search_zh":"水、生活饮用水、污水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002 M","technique_zh":"重量法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29d1","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, wody opadowe i roztopowe, ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(4,0 - 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (4,0 - 5000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007 M","norm_bases":["PN-EN 872:2007","PN-EN 872:2007/Ap1:2007 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, wody opadowe i roztopowe, ścieki Zawiesiny ogólne\nZakres (4,0 - 5000) mg/l\nMetoda wagowa PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007 M Woda, woda do spozycia przez ludzi, wody opadowe i roztopowe, scieki Zawiesiny ogolne\nZakres (4,0 - 5000) mg/l\nMetoda wagowa PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007 M","categories":["water"],"row_index":133,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(4,0 - 5000) mg/l"}],"search_en":"Water, water intended for human consumption, rainwater and snowmelt water, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007 M","technique_en":"Gravimetric method","test_object_en":"Water, water intended for human consumption, rainwater and snowmelt water, wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(4,0 - 5000) mg/l"}],"search_zh":"总悬浮物 重量法 范围 PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007 M","technique_zh":"重量法"},{"_id":"6a82c6ff884ede9a1b2c29d2","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Zasadowość alkaliczna (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zasadowość alkaliczna (z obliczeń)","reference":"PN-EN ISO 9963-1:2001 | PN-EN ISO 9963-1:2001/ Ap1:2004 | PN-EN ISO 11885:2009 M","norm_bases":["PN-EN ISO 9963-1:2001","PN-EN ISO 9963-1:2001/ Ap1:2004","PN-EN ISO 11885:2009 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Zasadowość alkaliczna (z obliczeń) PN-EN ISO 9963-1:2001 | PN-EN ISO 9963-1:2001/ Ap1:2004 | PN-EN ISO 11885:2009 M Woda, woda do spozycia przez ludzi, scieki Zasadowosc alkaliczna (z obliczen) PN-EN ISO 9963-1:2001 | PN-EN ISO 9963-1:2001/ Ap1:2004 | PN-EN ISO 11885:2009 M","categories":["water"],"row_index":134,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Alkaline alkalinity (calculated)","search_en":"Water, water intended for human consumption, wastewater Alkaline alkalinity (calculated) PN-EN ISO 9963-1:2001 | PN-EN ISO 9963-1:2001/ Ap1:2004 | PN-EN ISO 11885:2009 M","test_object_en":"Water, water intended for human consumption, wastewater","search_zh":"水、生活饮用水、污水 苛性碱度（由计算得出） PN-EN ISO 9963-1:2001 | PN-EN ISO 9963-1:2001/ Ap1:2004 | PN-EN ISO 11885:2009 M","test_object_zh":"水、生活饮用水、污水","methodology_zh":"苛性碱度（由计算得出）"},{"_id":"6a82c6ff884ede9a1b2c29d3","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Zasadowość ogólna","parameters":[{"name":"Zakres","range":"(0,20 – 100) mmol/l"},{"name":"Zasadowość mineralna"},{"name":"Zakres","range":"(0,20 – 100) mmol/l"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Zasadowość ogólna\nZakres:\nZakres (0,20 – 100) mmol/l\nZasadowość mineralna\nZakres (0,20 – 100) mmol/l\nMetoda miareczkowania potencjometrycznego","reference":"PN-EN ISO 9963-1:2001 | PN-EN ISO 9963-1:2001/ Ap1:2004 M","norm_bases":["PN-EN ISO 9963-1:2001","PN-EN ISO 9963-1:2001/ Ap1:2004 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Zasadowość ogólna\nZakres:\nZakres (0,20 – 100) mmol/l\nZasadowość mineralna\nZakres (0,20 – 100) mmol/l\nMetoda miareczkowania potencjometrycznego PN-EN ISO 9963-1:2001 | PN-EN ISO 9963-1:2001/ Ap1:2004 M Woda, woda do spozycia przez ludzi, scieki Zasadowosc ogolna\nZakres:\nZakres (0,20 – 100) mmol/l\nZasadowosc mineralna\nZakres (0,20 – 100) mmol/l\nMetoda miareczkowania potencjometrycznego PN-EN ISO 9963-1:2001 | PN-EN ISO 9963-1:2001/ Ap1:2004 M","categories":["water"],"row_index":135,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total alkalinity","parameters_en":[{"name":"Range","range":"(0,20 – 100) mmol/l"},{"name":"Mineral alkalinity"},{"name":"Range","range":"(0,20 – 100) mmol/l"}],"search_en":"Water, water intended for human consumption, wastewater Total alkalinity Potentiometric titration method Range Mineral alkalinity Range PN-EN ISO 9963-1:2001 | PN-EN ISO 9963-1:2001/ Ap1:2004 M","technique_en":"Potentiometric titration method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,20 – 100) mmol/l"},{"name":"矿物碱度"},{"name":"范围","range":"(0,20 – 100) mmol/l"}],"search_zh":"水、生活饮用水、污水 总碱度 电位滴定法 范围 矿物碱度 范围 PN-EN ISO 9963-1:2001 | PN-EN ISO 9963-1:2001/ Ap1:2004 M","technique_zh":"电位滴定法","test_object_zh":"水、生活饮用水、污水","methodology_zh":"总碱度"},{"_id":"6a82c6ff884ede9a1b2c29d4","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Kwasowość ogólna, kwasowość mineralna","parameters":[{"name":"Zakres","range":"(0,20 – 100) mmol/l"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Kwasowość ogólna, kwasowość mineralna\nZakres (0,20 – 100) mmol/l\nMetoda miareczkowania potencjometrycznego","reference":"PN-90/C-04540/02 | PN-90/C-04540/02/Az1:2003 M","norm_bases":["PN-90/C-04540/02","PN-90/C-04540/02/Az1:2003 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Kwasowość ogólna, kwasowość mineralna\nZakres (0,20 – 100) mmol/l\nMetoda miareczkowania potencjometrycznego PN-90/C-04540/02 | PN-90/C-04540/02/Az1:2003 M Woda, woda do spozycia przez ludzi, scieki Kwasowosc ogolna, kwasowosc mineralna\nZakres (0,20 – 100) mmol/l\nMetoda miareczkowania potencjometrycznego PN-90/C-04540/02 | PN-90/C-04540/02/Az1:2003 M","categories":["water"],"row_index":136,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total acidity, mineral acidity","parameters_en":[{"name":"Range","range":"(0,20 – 100) mmol/l"}],"search_en":"Water, water intended for human consumption, wastewater Total acidity, mineral acidity Potentiometric titration method Range PN-90/C-04540/02 | PN-90/C-04540/02/Az1:2003 M","technique_en":"Potentiometric titration method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,20 – 100) mmol/l"}],"search_zh":"水、生活饮用水、污水 电位滴定法 范围 PN-90/C-04540/02 | PN-90/C-04540/02/Az1:2003 M","technique_zh":"电位滴定法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29d5","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie wolnego dwutlenku węgla","parameters":[{"name":"Zakres","range":"(8,8 – 4400) mg/l CO2"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Stężenie wolnego dwutlenku węgla\nZakres (8,8 – 4400) mg/l CO2\nMetoda miareczkowania potencjometrycznego","reference":"PN-74/C-04547/01 pkt 2.1 M","norm_bases":["PN-74/C-04547/01 pkt 2.1 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie wolnego dwutlenku węgla\nZakres (8,8 – 4400) mg/l CO2\nMetoda miareczkowania potencjometrycznego PN-74/C-04547/01 pkt 2.1 M Woda, woda do spozycia przez ludzi, scieki Stezenie wolnego dwutlenku wegla\nZakres (8,8 – 4400) mg/l CO2\nMetoda miareczkowania potencjometrycznego PN-74/C-04547/01 pkt 2.1 M","categories":["water"],"row_index":137,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free carbon dioxide concentration","parameters_en":[{"name":"Range","range":"(8,8 – 4400) mg/l CO2"}],"search_en":"Water, water intended for human consumption, wastewater Free carbon dioxide concentration Potentiometric titration method Range PN-74/C-04547/01 pkt 2.1 M","technique_en":"Potentiometric titration method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(8,8 – 4400) mg/l CO2"}],"search_zh":"水、生活饮用水、污水 电位滴定法 范围 PN-74/C-04547/01 pkt 2.1 M","technique_zh":"电位滴定法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29d6","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie agresywnego dwutlenku węgla (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie agresywnego dwutlenku węgla (z obliczeń)","reference":"PN-74/C-04547/03 pkt 2.2 M","norm_bases":["PN-74/C-04547/03 pkt 2.2 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie agresywnego dwutlenku węgla (z obliczeń) PN-74/C-04547/03 pkt 2.2 M Woda, woda do spozycia przez ludzi, scieki Stezenie agresywnego dwutlenku wegla (z obliczen) PN-74/C-04547/03 pkt 2.2 M","categories":["water"],"row_index":138,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Aggressive carbon dioxide concentration (calculated)","search_en":"Water, water intended for human consumption, wastewater Aggressive carbon dioxide concentration (calculated) PN-74/C-04547/03 pkt 2.2 M","test_object_en":"Water, water intended for human consumption, wastewater","search_zh":"水、生活饮用水、污水 PN-74/C-04547/03 pkt 2.2 M","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29d7","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie węglanów (z obliczeń), Stężenie kwaśnych węglanów (wodorowęglanów) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie węglanów (z obliczeń), Stężenie kwaśnych węglanów (wodorowęglanów) (z obliczeń)","reference":"PN-EN ISO 9963-1:2001 | PN-EN ISO 9963-1:2001/ Ap1:2004 M","norm_bases":["PN-EN ISO 9963-1:2001","PN-EN ISO 9963-1:2001/ Ap1:2004 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie węglanów (z obliczeń), Stężenie kwaśnych węglanów (wodorowęglanów) (z obliczeń) PN-EN ISO 9963-1:2001 | PN-EN ISO 9963-1:2001/ Ap1:2004 M Woda, woda do spozycia przez ludzi, scieki Stezenie weglanow (z obliczen), Stezenie kwasnych weglanow (wodoroweglanow) (z obliczen) PN-EN ISO 9963-1:2001 | PN-EN ISO 9963-1:2001/ Ap1:2004 M","categories":["water"],"row_index":139,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbonate concentration (calculated), Acid carbonate (bicarbonate) concentration (calculated)","search_en":"Water, water intended for human consumption, wastewater Carbonate concentration (calculated), Acid carbonate (bicarbonate) concentration (calculated) PN-EN ISO 9963-1:2001 | PN-EN ISO 9963-1:2001/ Ap1:2004 M","test_object_en":"Water, water intended for human consumption, wastewater","search_zh":"水、生活饮用水、污水 PN-EN ISO 9963-1:2001 | PN-EN ISO 9963-1:2001/ Ap1:2004 M","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29d8","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Twardość węglanowa (z obliczeń), Twardość niewęglanowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Twardość węglanowa (z obliczeń), Twardość niewęglanowa (z obliczeń)","reference":"PN-EN ISO 9963-1:2001 | PN-EN ISO 9963-1:2001 /Ap1:2004 M","norm_bases":["PN-EN ISO 9963-1:2001","PN-EN ISO 9963-1:2001 /Ap1:2004 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Twardość węglanowa (z obliczeń), Twardość niewęglanowa (z obliczeń) PN-EN ISO 9963-1:2001 | PN-EN ISO 9963-1:2001 /Ap1:2004 M Woda, woda do spozycia przez ludzi Twardosc weglanowa (z obliczen), Twardosc nieweglanowa (z obliczen) PN-EN ISO 9963-1:2001 | PN-EN ISO 9963-1:2001 /Ap1:2004 M","categories":["water"],"row_index":140,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbonate hardness (calculated), Non-carbonate hardness (calculated)","search_en":"Water, water intended for human consumption Carbonate hardness (calculated), Non-carbonate hardness (calculated) PN-EN ISO 9963-1:2001 | PN-EN ISO 9963-1:2001 /Ap1:2004 M","test_object_en":"Water, water intended for human consumption","search_zh":"水、生活饮用水 PN-EN ISO 9963-1:2001 | PN-EN ISO 9963-1:2001 /Ap1:2004 M","test_object_zh":"水、生活饮用水"},{"_id":"6a82c6ff884ede9a1b2c29d9","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu (ChZT-Cr)","parameters":[{"name":"Zakres","range":"(15 – 10 000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu (ChZT-Cr)\nZakres (15 – 10 000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005 M","norm_bases":["PN-ISO 15705:2005 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Chemiczne zapotrzebowanie tlenu (ChZT-Cr)\nZakres (15 – 10 000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 M Woda, woda do spozycia przez ludzi, scieki Chemiczne zapotrzebowanie tlenu (ChZT-Cr)\nZakres (15 – 10 000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 M","categories":["water"],"row_index":141,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand (COD-Cr)","parameters_en":[{"name":"Range","range":"(15 – 10 000) mg/l O2"}],"search_en":"Water, water intended for human consumption, wastewater Chemical oxygen demand (COD-Cr) Spectrophotometric method Range PN-ISO 15705:2005 M","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"化学需氧量（ChZT-Cr / CODCr）","parameters_zh":[{"name":"范围","range":"(15 – 10 000) mg/l O2"}],"search_zh":"水、生活饮用水、污水 化学需氧量（ChZT-Cr / CODCr） 分光光度法 范围 PN-ISO 15705:2005 M","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29da","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie siarczynów","parameters":[{"name":"Zakres","range":"(0,10 - 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczynów\nZakres (0,10 - 100) mg/l\nMetoda spektrofotometryczna","reference":"PB-113/LF wyd. 3 z dnia 26.01.2022 na podstawie testu kuwetowego HACH nr LCW 054 M","norm_bases":["PB-113/LF wyd. 3 z dnia 26.01.2022 na podstawie testu kuwetowego HACH nr LCW 054 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie siarczynów\nZakres (0,10 - 100) mg/l\nMetoda spektrofotometryczna PB-113/LF wyd. 3 z dnia 26.01.2022 na podstawie testu kuwetowego HACH nr LCW 054 M Woda, woda do spozycia przez ludzi, scieki Stezenie siarczynow\nZakres (0,10 - 100) mg/l\nMetoda spektrofotometryczna PB-113/LF wyd. 3 z dnia 26.01.2022 na podstawie testu kuwetowego HACH nr LCW 054 M","categories":["water"],"row_index":142,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfite concentration","parameters_en":[{"name":"Range","range":"(0,10 - 100) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Sulfite concentration Spectrophotometric method Range PB-113/LF wyd. 3 z dnia 26.01.2022 na podstawie testu kuwetowego HACH nr LCW 054 M","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,10 - 100) mg/l"}],"search_zh":"水、生活饮用水、污水 亚硫酸盐浓度 分光光度法 范围 PB-113/LF wyd. 3 z dnia 26.01.2022 na podstawie testu kuwetowego HACH nr LCW 054 M","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水","methodology_zh":"亚硫酸盐浓度"},{"_id":"6a82c6ff884ede9a1b2c29db","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie siarkowodoru i siarczków","parameters":[{"name":"Zakres","range":"(0,10 - 20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarkowodoru i siarczków\nZakres (0,10 - 20) mg/l\nMetoda spektrofotometryczna","reference":"PB-114/LF wyd. 3 z dnia 26.01.2022 na podstawie testu kuwetowego HACH nr LCK 653 M","norm_bases":["PB-114/LF wyd. 3 z dnia 26.01.2022 na podstawie testu kuwetowego HACH nr LCK 653 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie siarkowodoru i siarczków\nZakres (0,10 - 20) mg/l\nMetoda spektrofotometryczna PB-114/LF wyd. 3 z dnia 26.01.2022 na podstawie testu kuwetowego HACH nr LCK 653 M Woda, woda do spozycia przez ludzi, scieki Stezenie siarkowodoru i siarczkow\nZakres (0,10 - 20) mg/l\nMetoda spektrofotometryczna PB-114/LF wyd. 3 z dnia 26.01.2022 na podstawie testu kuwetowego HACH nr LCK 653 M","categories":["water"],"row_index":143,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen sulfide and sulfide concentration","parameters_en":[{"name":"Range","range":"(0,10 - 20) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Hydrogen sulfide and sulfide concentration Spectrophotometric method Range PB-114/LF wyd. 3 z dnia 26.01.2022 na podstawie testu kuwetowego HACH nr LCK 653 M","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,10 - 20) mg/l"}],"search_zh":"水、生活饮用水、污水 硫化氢与硫化物浓度 分光光度法 范围 PB-114/LF wyd. 3 z dnia 26.01.2022 na podstawie testu kuwetowego HACH nr LCK 653 M","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水","methodology_zh":"硫化氢与硫化物浓度"},{"_id":"6a82c6ff884ede9a1b2c29dc","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie rodanków","parameters":[{"name":"Zakres","range":"(0,10 – 50) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie rodanków\nZakres (0,10 – 50) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-3:2001 M","norm_bases":["PN-EN ISO 10304-3:2001 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie rodanków\nZakres (0,10 – 50) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-3:2001 M Woda, woda do spozycia przez ludzi, scieki Stezenie rodankow\nZakres (0,10 – 50) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-3:2001 M","categories":["water"],"row_index":144,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Thiocyanate concentration","parameters_en":[{"name":"Range","range":"(0,10 – 50) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Thiocyanate concentration Ion chromatography with conductometric detection (IC-CD) Range PN-EN ISO 10304-3:2001 M","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,10 – 50) mg/l"}],"search_zh":"水、生活饮用水、污水 硫氰酸盐浓度 离子色谱-电导检测法（IC-CD） 范围 PN-EN ISO 10304-3:2001 M","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、生活饮用水、污水","methodology_zh":"硫氰酸盐浓度"},{"_id":"6a82c6ff884ede9a1b2c29dd","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie anionów","parameters":[{"name":"fluorki","range":"(0,10 - 20) mg/l"},{"name":"chlorki","range":"(2,0 - 500 ) mg/l"},{"name":"siarczany","range":"(2,0 - 500) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nfluorki (0,10 - 20) mg/l\nchlorki (2,0 - 500 ) mg/l\nsiarczany (2,0 - 500) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/ AC:2012 M","norm_bases":["PN-EN ISO 10304-1:2009","PN-EN ISO 10304-1:2009/ AC:2012 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie anionów\nZakres:\nfluorki (0,10 - 20) mg/l\nchlorki (2,0 - 500 ) mg/l\nsiarczany (2,0 - 500) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/ AC:2012 M Woda, woda do spozycia przez ludzi, scieki Stezenie anionow\nZakres:\nfluorki (0,10 - 20) mg/l\nchlorki (2,0 - 500 ) mg/l\nsiarczany (2,0 - 500) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/ AC:2012 M","categories":["water"],"row_index":145,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"fluorides","range":"(0,10 - 20) mg/l"},{"name":"chlorides","range":"(2,0 - 500 ) mg/l"},{"name":"sulfates","range":"(2,0 - 500) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Anion concentrations Ion chromatography with conductometric detection (IC-CD) fluorides chlorides sulfates PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/ AC:2012 M","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"阴离子浓度","search_zh":"水、生活饮用水、污水 阴离子浓度 离子色谱-电导检测法（IC-CD） 氟化物 氯化物 硫酸盐 PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/ AC:2012 M","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、生活饮用水、污水","parameters_zh":[{"name":"氟化物","range":"(0,10 - 20) mg/l"},{"name":"氯化物","range":"(2,0 - 500 ) mg/l"},{"name":"硫酸盐","range":"(2,0 - 500) mg/l"}]},{"_id":"6a82c6ff884ede9a1b2c29de","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 50 000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 50 000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994 M","norm_bases":["PN-ISO 9297:1994 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie chlorków\nZakres (5,0 – 50 000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 M Woda, woda do spozycia przez ludzi, scieki Stezenie chlorkow\nZakres (5,0 – 50 000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 M","categories":["water"],"row_index":146,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 50 000) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994 M","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 50 000) mg/l"}],"search_zh":"水、生活饮用水、污水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994 M","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29df","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie fluorków","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/l"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Stężenie fluorków\nZakres (0,10 – 100) mg/l\nMetoda potencjometryczna","reference":"PN-78/C-04588/03 M","norm_bases":["PN-78/C-04588/03 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie fluorków\nZakres (0,10 – 100) mg/l\nMetoda potencjometryczna PN-78/C-04588/03 M Woda, woda do spozycia przez ludzi, scieki Stezenie fluorkow\nZakres (0,10 – 100) mg/l\nMetoda potencjometryczna PN-78/C-04588/03 M","categories":["water"],"row_index":147,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fluoride concentration","parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Fluoride concentration Potentiometric method Range PN-78/C-04588/03 M","technique_en":"Potentiometric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/l"}],"search_zh":"水、生活饮用水、污水 氟化物浓度 电位法 范围 PN-78/C-04588/03 M","technique_zh":"电位法","test_object_zh":"水、生活饮用水、污水","methodology_zh":"氟化物浓度"},{"_id":"6a82c6ff884ede9a1b2c29e0","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(5,0 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (5,0 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001 M","norm_bases":["PN-EN 25663:2001 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie azotu Kjeldahla\nZakres (5,0 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 M Woda, woda do spozycia przez ludzi, scieki Stezenie azotu Kjeldahla\nZakres (5,0 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 M","categories":["water"],"row_index":148,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(5,0 – 1000) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001 M","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 1000) mg/l"}],"search_zh":"水、生活饮用水、污水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001 M","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29e1","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(10 – 1000) mg/l"},{"name":"Stężenie jonu amonowego/amoniaku (z obliczeń)"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres:\nZakres (10 – 1000) mg/l\nStężenie jonu amonowego/amoniaku (z obliczeń)\nMetoda miareczkowa","reference":"PN-ISO 5664:2002 M","norm_bases":["PN-ISO 5664:2002 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie azotu amonowego\nZakres:\nZakres (10 – 1000) mg/l\nStężenie jonu amonowego/amoniaku (z obliczeń)\nMetoda miareczkowa PN-ISO 5664:2002 M Woda, woda do spozycia przez ludzi, scieki Stezenie azotu amonowego\nZakres:\nZakres (10 – 1000) mg/l\nStezenie jonu amonowego/amoniaku (z obliczen)\nMetoda miareczkowa PN-ISO 5664:2002 M","categories":["water"],"row_index":149,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(10 – 1000) mg/l"},{"name":"Ammonium ion/ammonia concentration (calculated)"}],"search_en":"Water, water intended for human consumption, wastewater Ammonium nitrogen concentration Titrimetric method Range Ammonium ion/ammonia concentration (calculated) PN-ISO 5664:2002 M","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(10 – 1000) mg/l"},{"name":"Stężenie jonu amonowego/amoniaku (z obliczeń)"}],"search_zh":"水、生活饮用水、污水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002 M","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29e2","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/l"},{"name":"Stężenie jonu amonowego/amoniaku (z obliczeń)"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres:\nZakres (0,10 – 100) mg/l\nStężenie jonu amonowego/amoniaku (z obliczeń)\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 11732:2007 pkt 4 M","norm_bases":["PN-EN ISO 11732:2007 pkt 4 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie azotu amonowego\nZakres:\nZakres (0,10 – 100) mg/l\nStężenie jonu amonowego/amoniaku (z obliczeń)\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 11732:2007 pkt 4 M Woda, woda do spozycia przez ludzi, scieki Stezenie azotu amonowego\nZakres:\nZakres (0,10 – 100) mg/l\nStezenie jonu amonowego/amoniaku (z obliczen)\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 11732:2007 pkt 4 M","categories":["water"],"row_index":150,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/l"},{"name":"Ammonium ion/ammonia concentration (calculated)"}],"search_en":"Water, water intended for human consumption, wastewater Ammonium nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range Ammonium ion/ammonia concentration (calculated) PN-EN ISO 11732:2007 pkt 4 M","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/l"},{"name":"Stężenie jonu amonowego/amoniaku (z obliczeń)"}],"search_zh":"水、生活饮用水、污水 氨氮浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 11732:2007 pkt 4 M","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29e3","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,20 - 100) mg/l"},{"name":"Stężenie azotanów (z obliczeń)"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres:\nZakres (0,20 - 100) mg/l\nStężenie azotanów (z obliczeń)\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 13395:2001 M","norm_bases":["PN-EN ISO 13395:2001 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie azotu azotanowego\nZakres:\nZakres (0,20 - 100) mg/l\nStężenie azotanów (z obliczeń)\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 13395:2001 M Woda, woda do spozycia przez ludzi, scieki Stezenie azotu azotanowego\nZakres:\nZakres (0,20 - 100) mg/l\nStezenie azotanow (z obliczen)\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 13395:2001 M","categories":["water"],"row_index":151,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,20 - 100) mg/l"},{"name":"Nitrate concentration (calculated)"}],"search_en":"Water, water intended for human consumption, wastewater Nitrate nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range Nitrate concentration (calculated) PN-EN ISO 13395:2001 M","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,20 - 100) mg/l"},{"name":"硝酸盐浓度（由计算得出）"}],"search_zh":"水、生活饮用水、污水 硝态氮浓度 连续流动分析（CFA）分光光度检测法 范围 硝酸盐浓度（由计算得出） PN-EN ISO 13395:2001 M","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29e4","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,020 – 4,0) mg/l"},{"name":"Stężenie azotynów (z obliczeń)"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres:\nZakres (0,020 – 4,0) mg/l\nStężenie azotynów (z obliczeń)\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 13395:2001 M","norm_bases":["PN-EN ISO 13395:2001 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie azotu azotynowego\nZakres:\nZakres (0,020 – 4,0) mg/l\nStężenie azotynów (z obliczeń)\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 13395:2001 M Woda, woda do spozycia przez ludzi, scieki Stezenie azotu azotynowego\nZakres:\nZakres (0,020 – 4,0) mg/l\nStezenie azotynow (z obliczen)\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 13395:2001 M","categories":["water"],"row_index":152,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,020 – 4,0) mg/l"},{"name":"Nitrite concentration (calculated)"}],"search_en":"Water, water intended for human consumption, wastewater Nitrite nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range Nitrite concentration (calculated) PN-EN ISO 13395:2001 M","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,020 – 4,0) mg/l"},{"name":"亚硝酸盐浓度（由计算得出）"}],"search_zh":"水、生活饮用水、污水 亚硝态氮浓度 连续流动分析（CFA）分光光度检测法 范围 亚硝酸盐浓度（由计算得出） PN-EN ISO 13395:2001 M","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29e5","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(0,50 - 2000) mg/l"}],"technique":"Metoda chemiluminescencyjna","techniques":["Metoda chemiluminescencyjna"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (0,50 - 2000) mg/l\nMetoda chemiluminescencyjna","reference":"PN EN- ISO 20236:2025-05 M","norm_bases":["PN EN- ISO 20236:2025-05 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie azotu ogólnego\nZakres (0,50 - 2000) mg/l\nMetoda chemiluminescencyjna PN EN- ISO 20236:2025-05 M Woda, woda do spozycia przez ludzi, scieki Stezenie azotu ogolnego\nZakres (0,50 - 2000) mg/l\nMetoda chemiluminescencyjna PN EN- ISO 20236:2025-05 M","categories":["water"],"row_index":153,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,50 - 2000) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Total nitrogen concentration Chemiluminescence method Range PN EN- ISO 20236:2025-05 M","technique_en":"Chemiluminescence method","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(0,50 - 2000) mg/l"}],"search_zh":"水、生活饮用水、污水 总氮浓度 化学发光法 范围 PN EN- ISO 20236:2025-05 M","test_object_zh":"水、生活饮用水、污水","technique_zh":"化学发光法"},{"_id":"6a82c6ff884ede9a1b2c29e6","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń), Stężenie azotu organicznego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń), Stężenie azotu organicznego (z obliczeń)","reference":"PN-73/C-04576/14 M","norm_bases":["PN-73/C-04576/14 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie azotu ogólnego (z obliczeń), Stężenie azotu organicznego (z obliczeń) PN-73/C-04576/14 M Woda, woda do spozycia przez ludzi, scieki Stezenie azotu ogolnego (z obliczen), Stezenie azotu organicznego (z obliczen) PN-73/C-04576/14 M","categories":["water"],"row_index":154,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration (calculated), Organic nitrogen concentration (calculated)","search_en":"Water, water intended for human consumption, wastewater Total nitrogen concentration (calculated), Organic nitrogen concentration (calculated) PN-73/C-04576/14 M","test_object_en":"Water, water intended for human consumption, wastewater","search_zh":"水、生活饮用水、污水 PN-73/C-04576/14 M","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29e7","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie rodanków","parameters":[{"name":"Zakres","range":"(0,50 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie rodanków\nZakres (0,50 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-81/C-04566-08 M","norm_bases":["PN-81/C-04566-08 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie rodanków\nZakres (0,50 – 100) mg/l\nMetoda spektrofotometryczna PN-81/C-04566-08 M Woda, woda do spozycia przez ludzi, scieki Stezenie rodankow\nZakres (0,50 – 100) mg/l\nMetoda spektrofotometryczna PN-81/C-04566-08 M","categories":["water"],"row_index":155,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Thiocyanate concentration","parameters_en":[{"name":"Range","range":"(0,50 – 100) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Thiocyanate concentration Spectrophotometric method Range PN-81/C-04566-08 M","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,50 – 100) mg/l"}],"search_zh":"水、生活饮用水、污水 硫氰酸盐浓度 分光光度法 范围 PN-81/C-04566-08 M","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水","methodology_zh":"硫氰酸盐浓度"},{"_id":"6a82c6ff884ede9a1b2c29e8","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie fosforanów(V)","parameters":[{"name":"Zakres","range":"(0,050 – 200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforanów(V)\nZakres (0,050 – 200) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt 4 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010 M","norm_bases":["PN-EN ISO 6878:2006 pkt 4","PN-EN ISO 6878:2006/Ap1:2010","PN-EN ISO 6878:2006/Ap2:2010 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie fosforanów(V)\nZakres (0,050 – 200) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 4 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010 M Woda, woda do spozycia przez ludzi, scieki Stezenie fosforanow(V)\nZakres (0,050 – 200) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 4 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010 M","categories":["water"],"row_index":156,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phosphate(V) concentration","parameters_en":[{"name":"Range","range":"(0,050 – 200) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Phosphate(V) concentration Spectrophotometric method Range PN-EN ISO 6878:2006 pkt 4 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010 M","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,050 – 200) mg/l"}],"search_zh":"水、生活饮用水、污水 分光光度法 范围 PN-EN ISO 6878:2006 pkt 4 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010 M","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29e9","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie krzemionki zdysocjowanej","parameters":[{"name":"Zakres","range":"(0,50 – 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie krzemionki zdysocjowanej\nZakres (0,50 – 50) mg/l\nMetoda spektrofotometryczna","reference":"PN-71/C-04567/02 M","norm_bases":["PN-71/C-04567/02 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie krzemionki zdysocjowanej\nZakres (0,50 – 50) mg/l\nMetoda spektrofotometryczna PN-71/C-04567/02 M Woda, woda do spozycia przez ludzi, scieki Stezenie krzemionki zdysocjowanej\nZakres (0,50 – 50) mg/l\nMetoda spektrofotometryczna PN-71/C-04567/02 M","categories":["water"],"row_index":157,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissociated silica concentration","parameters_en":[{"name":"Range","range":"(0,50 – 50) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Dissociated silica concentration Spectrophotometric method Range PN-71/C-04567/02 M","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,50 – 50) mg/l"}],"search_zh":"水、生活饮用水、污水 解离二氧化硅浓度 分光光度法 范围 PN-71/C-04567/02 M","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水","methodology_zh":"解离二氧化硅浓度"},{"_id":"6a82c6ff884ede9a1b2c29ea","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"(2,0 – 12,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (2,0 – 12,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012 M","norm_bases":["PN-EN ISO 10523:2012 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki pH\nZakres (2,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 M Woda, woda do spozycia przez ludzi, scieki pH\nZakres (2,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 M","categories":["water"],"row_index":158,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"(2,0 – 12,0)"}],"search_en":"Water, water intended for human consumption, wastewater pH Potentiometric method Range PN-EN ISO 10523:2012 M","technique_en":"Potentiometric method","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(2,0 – 12,0)"}],"search_zh":"水、生活饮用水、污水 pH 值 电位法 范围 PN-EN ISO 10523:2012 M","technique_zh":"电位法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29eb","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10 – 12 000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (10 – 12 000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999 M","norm_bases":["PN-EN 27888:1999 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Przewodność elektryczna właściwa\nZakres (10 – 12 000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 M Woda, woda do spozycia przez ludzi, scieki Przewodnosc elektryczna wlasciwa\nZakres (10 – 12 000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 M","categories":["water"],"row_index":159,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(10 – 12 000) μS/cm"}],"search_en":"Water, water intended for human consumption, wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999 M","technique_en":"Conductometric method","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10 – 12 000) μS/cm"}],"search_zh":"水、生活饮用水、污水 电导率 电导法 范围 PN-EN 27888:1999 M","technique_zh":"电导法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29ec","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Ścieki, wody technologiczne","methodology":"Gęstość (20°C)","parameters":[{"name":"Zakres","range":"(0,90 – 1,35) kg/dm3"}],"technique":"Metoda piknometryczna","techniques":["Metoda piknometryczna"],"computed":[],"activity":"Gęstość (20°C)\nZakres (0,90 – 1,35) kg/dm3\nMetoda piknometryczna","reference":"ISO 758:1976 M","norm_bases":["ISO 758:1976 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, wody technologiczne Gęstość (20°C)\nZakres (0,90 – 1,35) kg/dm3\nMetoda piknometryczna ISO 758:1976 M Scieki, wody technologiczne Gestosc (20°C)\nZakres (0,90 – 1,35) kg/dm3\nMetoda piknometryczna ISO 758:1976 M","categories":["water"],"row_index":160,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density (20°C)","parameters_en":[{"name":"Range","range":"(0,90 – 1,35) kg/dm3"}],"search_en":"Wastewater, process waters Density (20°C) Pycnometric method Range ISO 758:1976 M","technique_en":"Pycnometric method","test_object_en":"Wastewater, process waters","parameters_zh":[{"name":"范围","range":"(0,90 – 1,35) kg/dm3"}],"search_zh":"比重瓶法 范围 ISO 758:1976 M","technique_zh":"比重瓶法"},{"_id":"6a82c6ff884ede9a1b2c29ed","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie chromu(VI)","parameters":[{"name":"Zakres","range":"(0,010 – 5,0) mg/l"},{"name":"Stężenie chromu(III) (z obliczeń)"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chromu(VI)\nZakres:\nZakres (0,010 – 5,0) mg/l\nStężenie chromu(III) (z obliczeń)\nMetoda spektrofotometryczna","reference":"PN-EN ISO 18412:2007 M","norm_bases":["PN-EN ISO 18412:2007 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie chromu(VI)\nZakres:\nZakres (0,010 – 5,0) mg/l\nStężenie chromu(III) (z obliczeń)\nMetoda spektrofotometryczna PN-EN ISO 18412:2007 M Woda, woda do spozycia przez ludzi, scieki Stezenie chromu(VI)\nZakres:\nZakres (0,010 – 5,0) mg/l\nStezenie chromu(III) (z obliczen)\nMetoda spektrofotometryczna PN-EN ISO 18412:2007 M","categories":["water"],"row_index":161,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium(VI) concentration","parameters_en":[{"name":"Range","range":"(0,010 – 5,0) mg/l"},{"name":"Chromium(III) concentration (calculated)"}],"search_en":"Water, water intended for human consumption, wastewater Chromium(VI) concentration Spectrophotometric method Range Chromium(III) concentration (calculated) PN-EN ISO 18412:2007 M","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,010 – 5,0) mg/l"},{"name":"Stężenie chromu(III) (z obliczeń)"}],"search_zh":"水、生活饮用水、污水 分光光度法 范围 PN-EN ISO 18412:2007 M","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29ee","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie cyjanków wolnych, ogólnych","parameters":[{"name":"Zakres","range":"(0,010 – 10) mg/l"},{"name":"Stężenie cyjanków związanych (z obliczeń)"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie cyjanków wolnych, ogólnych\nZakres:\nZakres (0,010 – 10) mg/l\nStężenie cyjanków związanych (z obliczeń)\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 14403-2:2012 M","norm_bases":["PN-EN ISO 14403-2:2012 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie cyjanków wolnych, ogólnych\nZakres:\nZakres (0,010 – 10) mg/l\nStężenie cyjanków związanych (z obliczeń)\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 14403-2:2012 M Woda, woda do spozycia przez ludzi, scieki Stezenie cyjankow wolnych, ogolnych\nZakres:\nZakres (0,010 – 10) mg/l\nStezenie cyjankow zwiazanych (z obliczen)\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 14403-2:2012 M","categories":["water"],"row_index":162,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free, total cyanide concentration","parameters_en":[{"name":"Range","range":"(0,010 – 10) mg/l"},{"name":"Combined cyanide concentration (calculated)"}],"search_en":"Water, water intended for human consumption, wastewater Free, total cyanide concentration Continuous flow analysis (CFA) with spectrophotometric detection Range Combined cyanide concentration (calculated) PN-EN ISO 14403-2:2012 M","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,010 – 10) mg/l"},{"name":"络合氰化物浓度（由计算得出）"}],"search_zh":"水、生活饮用水、污水 连续流动分析（CFA）分光光度检测法 范围 络合氰化物浓度（由计算得出） PN-EN ISO 14403-2:2012 M","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29ef","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Indeks fenolowy (fenol)","parameters":[{"name":"Zakres","range":"(0,0050 – 2,5) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Indeks fenolowy (fenol)\nZakres (0,0050 – 2,5) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 14402:2004 pkt 4 M","norm_bases":["PN-EN ISO 14402:2004 pkt 4 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Indeks fenolowy (fenol)\nZakres (0,0050 – 2,5) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 14402:2004 pkt 4 M Woda, woda do spozycia przez ludzi, scieki Indeks fenolowy (fenol)\nZakres (0,0050 – 2,5) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 14402:2004 pkt 4 M","categories":["water"],"row_index":163,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol index (phenol)","parameters_en":[{"name":"Range","range":"(0,0050 – 2,5) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Phenol index (phenol) Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 14402:2004 pkt 4 M","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,0050 – 2,5) mg/l"}],"search_zh":"水、生活饮用水、污水 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 14402:2004 pkt 4 M","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29f0","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Adsorbowalne związki chloroorganiczne (AOX)","parameters":[{"name":"Zakres","range":"(0,05 - 3,0) mg/l Cl"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Adsorbowalne związki chloroorganiczne (AOX)\nZakres (0,05 - 3,0) mg/l Cl\nMetoda spektrofotometryczna","reference":"PB-143/LF wyd. 4 z dnia 14.01.2025 na podstawie testu kuwetowego HACH nr LCK 390 M","norm_bases":["PB-143/LF wyd. 4 z dnia 14.01.2025 na podstawie testu kuwetowego HACH nr LCK 390 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Adsorbowalne związki chloroorganiczne (AOX)\nZakres (0,05 - 3,0) mg/l Cl\nMetoda spektrofotometryczna PB-143/LF wyd. 4 z dnia 14.01.2025 na podstawie testu kuwetowego HACH nr LCK 390 M Woda, scieki Adsorbowalne zwiazki chloroorganiczne (AOX)\nZakres (0,05 - 3,0) mg/l Cl\nMetoda spektrofotometryczna PB-143/LF wyd. 4 z dnia 14.01.2025 na podstawie testu kuwetowego HACH nr LCK 390 M","categories":["water"],"row_index":164,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Adsorbable organochlorine compounds (AOX)","parameters_en":[{"name":"Range","range":"(0,05 - 3,0) mg/l Cl"}],"search_en":"Water, wastewater Adsorbable organochlorine compounds (AOX) Spectrophotometric method Range PB-143/LF wyd. 4 z dnia 14.01.2025 na podstawie testu kuwetowego HACH nr LCK 390 M","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,05 - 3,0) mg/l Cl"}],"search_zh":"水、废水 分光光度法 范围 PB-143/LF wyd. 4 z dnia 14.01.2025 na podstawie testu kuwetowego HACH nr LCK 390 M","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a82c6ff884ede9a1b2c29f1","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie ogólnego węgla","parameters":[{"name":"organicznego (OWO), rozpuszczonego węgla organicznego (RWO)"},{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Stężenie ogólnego węgla\nZakres:\norganicznego (OWO), rozpuszczonego węgla organicznego (RWO)\nZakres (2,0 – 1000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 1484:1999 M","norm_bases":["PN-EN 1484:1999 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie ogólnego węgla\nZakres:\norganicznego (OWO), rozpuszczonego węgla organicznego (RWO)\nZakres (2,0 – 1000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 1484:1999 M Woda, woda do spozycia przez ludzi, scieki Stezenie ogolnego wegla\nZakres:\norganicznego (OWO), rozpuszczonego wegla organicznego (RWO)\nZakres (2,0 – 1000) mg/l\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 1484:1999 M","categories":["water"],"row_index":165,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon concentration","parameters_en":[{"name":"organic (TOC), dissolved organic carbon (DOC)"},{"name":"Range","range":"(2,0 – 1000) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Total carbon concentration High-temperature combustion with IR detection organic (TOC), dissolved organic carbon (DOC) Range PN-EN 1484:1999 M","technique_en":"High-temperature combustion with IR detection","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"organicznego (OWO), rozpuszczonego węgla organicznego (RWO)"},{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"水、生活饮用水、污水 总碳浓度 高温燃烧红外检测法 范围 PN-EN 1484:1999 M","technique_zh":"高温燃烧红外检测法","test_object_zh":"水、生活饮用水、污水","methodology_zh":"总碳浓度"},{"_id":"6a82c6ff884ede9a1b2c29f2","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie anionów","parameters":[{"name":"siarczany(VI)","range":"(10 - 5000) mg/l"},{"name":"chlorki","range":"(1,0 - 50 000) mg/l"},{"name":"fosforany(V)","range":"(0,060 – 200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie anionów\nZakres:\nsiarczany(VI) (10 - 5000) mg/l\nchlorki (1,0 - 50 000) mg/l\nfosforany(V) (0,060 – 200) mg/l\nMetoda spektrofotometryczna","reference":"PB-101/LF wyd. 4 z dnia 26.01.2022 M","norm_bases":["PB-101/LF wyd. 4 z dnia 26.01.2022 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie anionów\nZakres:\nsiarczany(VI) (10 - 5000) mg/l\nchlorki (1,0 - 50 000) mg/l\nfosforany(V) (0,060 – 200) mg/l\nMetoda spektrofotometryczna PB-101/LF wyd. 4 z dnia 26.01.2022 M Woda, woda do spozycia przez ludzi, scieki Stezenie anionow\nZakres:\nsiarczany(VI) (10 - 5000) mg/l\nchlorki (1,0 - 50 000) mg/l\nfosforany(V) (0,060 – 200) mg/l\nMetoda spektrofotometryczna PB-101/LF wyd. 4 z dnia 26.01.2022 M","categories":["water"],"row_index":166,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"sulfates(VI)","range":"(10 - 5000) mg/l"},{"name":"chlorides","range":"(1,0 - 50 000) mg/l"},{"name":"phosphates(V)","range":"(0,060 – 200) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Anion concentrations Spectrophotometric method sulfates(VI) chlorides phosphates(V) PB-101/LF wyd. 4 z dnia 26.01.2022 M","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"阴离子浓度","search_zh":"水、生活饮用水、污水 阴离子浓度 分光光度法 氯化物 PB-101/LF wyd. 4 z dnia 26.01.2022 M","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水","parameters_zh":[{"name":"siarczany(VI)","range":"(10 - 5000) mg/l"},{"name":"氯化物","range":"(1,0 - 50 000) mg/l"},{"name":"fosforany(V)","range":"(0,060 – 200) mg/l"}]},{"_id":"6a82c6ff884ede9a1b2c29f3","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Zasadowość ogólna","parameters":[{"name":"Zakres","range":"(0,98 - 100) mmol/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zasadowość ogólna\nZakres (0,98 - 100) mmol/l\nMetoda spektrofotometryczna","reference":"PB-101/LF wyd. 4 z dnia 26.01.2022 M","norm_bases":["PB-101/LF wyd. 4 z dnia 26.01.2022 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Zasadowość ogólna\nZakres (0,98 - 100) mmol/l\nMetoda spektrofotometryczna PB-101/LF wyd. 4 z dnia 26.01.2022 M Woda, woda do spozycia przez ludzi, scieki Zasadowosc ogolna\nZakres (0,98 - 100) mmol/l\nMetoda spektrofotometryczna PB-101/LF wyd. 4 z dnia 26.01.2022 M","categories":["water"],"row_index":167,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total alkalinity","parameters_en":[{"name":"Range","range":"(0,98 - 100) mmol/l"}],"search_en":"Water, water intended for human consumption, wastewater Total alkalinity Spectrophotometric method Range PB-101/LF wyd. 4 z dnia 26.01.2022 M","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,98 - 100) mmol/l"}],"search_zh":"水、生活饮用水、污水 总碱度 分光光度法 范围 PB-101/LF wyd. 4 z dnia 26.01.2022 M","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水","methodology_zh":"总碱度"},{"_id":"6a82c6ff884ede9a1b2c29f4","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Twardość ogólna (sumaryczna zawartość wapnia i magnezu) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Twardość ogólna (sumaryczna zawartość wapnia i magnezu) (z obliczeń)","reference":"PN-EN ISO 11885:2009 M","norm_bases":["PN-EN ISO 11885:2009 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Twardość ogólna (sumaryczna zawartość wapnia i magnezu) (z obliczeń) PN-EN ISO 11885:2009 M Woda, woda do spozycia przez ludzi, scieki Twardosc ogolna (sumaryczna zawartosc wapnia i magnezu) (z obliczen) PN-EN ISO 11885:2009 M","categories":["water"],"row_index":168,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total hardness (total calcium and magnesium content) (calculated)","search_en":"Water, water intended for human consumption, wastewater Total hardness (total calcium and magnesium content) (calculated) PN-EN ISO 11885:2009 M","test_object_en":"Water, water intended for human consumption, wastewater","search_zh":"水、生活饮用水、污水 PN-EN ISO 11885:2009 M","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29f5","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Ścieki","methodology":"Suma chlorków i siarczanów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma chlorków i siarczanów (z obliczeń)","reference":"PN-ISO 9297:1994 | PN-ISO 9280:2002 M","norm_bases":["PN-ISO 9297:1994","PN-ISO 9280:2002 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Suma chlorków i siarczanów (z obliczeń) PN-ISO 9297:1994 | PN-ISO 9280:2002 M Scieki Suma chlorkow i siarczanow (z obliczen) PN-ISO 9297:1994 | PN-ISO 9280:2002 M","categories":["water"],"row_index":169,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of chlorides and sulphates (calculated)","search_en":"Wastewater Sum of chlorides and sulphates (calculated) PN-ISO 9297:1994 | PN-ISO 9280:2002 M","test_object_en":"Wastewater","search_zh":"污水 氯化物与硫酸盐总量（由计算得出） PN-ISO 9297:1994 | PN-ISO 9280:2002 M","test_object_zh":"污水","methodology_zh":"氯化物与硫酸盐总量（由计算得出）"},{"_id":"6a82c6ff884ede9a1b2c29f6","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Ścieki","methodology":"Suma surfaktantów anionowych i niejonowych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma surfaktantów anionowych i niejonowych (z obliczeń)","reference":"PN-EN ISO 16265:2012 | PB-12/LF wyd. 4 z dnia 7.01.2026 M","norm_bases":["PN-EN ISO 16265:2012","PB-12/LF wyd. 4 z dnia 7.01.2026 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Suma surfaktantów anionowych i niejonowych (z obliczeń) PN-EN ISO 16265:2012 | PB-12/LF wyd. 4 z dnia 7.01.2026 M Scieki Suma surfaktantow anionowych i niejonowych (z obliczen) PN-EN ISO 16265:2012 | PB-12/LF wyd. 4 z dnia 7.01.2026 M","categories":["water"],"row_index":170,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of anionic and non-ionic surfactants (calculated)","search_en":"Wastewater Sum of anionic and non-ionic surfactants (calculated) PN-EN ISO 16265:2012 | PB-12/LF wyd. 4 z dnia 7.01.2026 M","test_object_en":"Wastewater","search_zh":"污水 PN-EN ISO 16265:2012 | PB-12/LF wyd. 4 z dnia 7.01.2026 M","test_object_zh":"污水"},{"_id":"6a82c6ff884ede9a1b2c29f7","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie węglowodorów C6-C12 / benzyny","parameters":[{"name":"Zakres","range":"(0,050 – 250) mg/l"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)"],"computed":[],"activity":"Stężenie węglowodorów C6-C12 / benzyny\nZakres (0,050 – 250) mg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","reference":"PB-146/LF wyd. 4 z dnia 20.01.2022 M","norm_bases":["PB-146/LF wyd. 4 z dnia 20.01.2022 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie węglowodorów C6-C12 / benzyny\nZakres (0,050 – 250) mg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID) PB-146/LF wyd. 4 z dnia 20.01.2022 M Woda, woda do spozycia przez ludzi, scieki Stezenie weglowodorow C6-C12 / benzyny\nZakres (0,050 – 250) mg/l\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja plomieniowo-jonizacyjna (HS-GC-FID) PB-146/LF wyd. 4 z dnia 20.01.2022 M","categories":["water"],"row_index":171,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of C6-C12 hydrocarbons / gasoline","parameters_en":[{"name":"Range","range":"(0,050 – 250) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Concentration of C6-C12 hydrocarbons / gasoline Headspace gas chromatography with flame ionization detection (HS-GC-FID) Range PB-146/LF wyd. 4 z dnia 20.01.2022 M","technique_en":"Headspace gas chromatography with flame ionization detection (HS-GC-FID)","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,050 – 250) mg/l"}],"search_zh":"水、生活饮用水、污水 顶空气相色谱-火焰离子化检测法（HS-GC-FID） 范围 PB-146/LF wyd. 4 z dnia 20.01.2022 M","test_object_zh":"水、生活饮用水、污水","technique_zh":"顶空气相色谱-火焰离子化检测法（HS-GC-FID）"},{"_id":"6a82c6ff884ede9a1b2c29f8","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie lotnych węglowodorów aromatycznych (BTX)","parameters":[{"name":"benzen","range":"(0,25 – 5000) μg/l"},{"name":"etylobenzen","range":"(0,50 – 5000) μg/l"},{"name":"toluen","range":"(0,50 – 5000) μg/l"},{"name":"o-ksylen","range":"(0,50 – 5000) μg/l"},{"name":"m+p-ksyleny","range":"(1,0 – 10 000) μg/l"},{"name":"styren","range":"(0,50 - 5000) μg/l"},{"name":"Suma lotnych węglowodorów aromatycznych (BTX) (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)"],"computed":[],"activity":"Stężenie lotnych węglowodorów aromatycznych (BTX)\nZakres:\nbenzen (0,25 – 5000) μg/l\netylobenzen (0,50 – 5000) μg/l\ntoluen (0,50 – 5000) μg/l\no-ksylen (0,50 – 5000) μg/l\nm+p-ksyleny (1,0 – 10 000) μg/l\nstyren (0,50 - 5000) μg/l\nSuma lotnych węglowodorów aromatycznych (BTX) (z obliczeń)\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","reference":"PN-ISO 11423-1:2002 M","norm_bases":["PN-ISO 11423-1:2002 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie lotnych węglowodorów aromatycznych (BTX)\nZakres:\nbenzen (0,25 – 5000) μg/l\netylobenzen (0,50 – 5000) μg/l\ntoluen (0,50 – 5000) μg/l\no-ksylen (0,50 – 5000) μg/l\nm+p-ksyleny (1,0 – 10 000) μg/l\nstyren (0,50 - 5000) μg/l\nSuma lotnych węglowodorów aromatycznych (BTX) (z obliczeń)\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) PN-ISO 11423-1:2002 M Woda, woda do spozycia przez ludzi, scieki Stezenie lotnych weglowodorow aromatycznych (BTX)\nZakres:\nbenzen (0,25 – 5000) μg/l\netylobenzen (0,50 – 5000) μg/l\ntoluen (0,50 – 5000) μg/l\no-ksylen (0,50 – 5000) μg/l\nm+p-ksyleny (1,0 – 10 000) μg/l\nstyren (0,50 - 5000) μg/l\nSuma lotnych weglowodorow aromatycznych (BTX) (z obliczen)\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) PN-ISO 11423-1:2002 M","categories":["water"],"row_index":172,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile aromatic hydrocarbons (BTX) concentration","parameters_en":[{"name":"benzene","range":"(0,25 – 5000) μg/l"},{"name":"ethylbenzene","range":"(0,50 – 5000) μg/l"},{"name":"toluene","range":"(0,50 – 5000) μg/l"},{"name":"o-xylene","range":"(0,50 – 5000) μg/l"},{"name":"m+p-xylenes","range":"(1,0 – 10 000) μg/l"},{"name":"styrene","range":"(0,50 - 5000) μg/l"},{"name":"Sum of volatile aromatic hydrocarbons (BTX) (calculated)"}],"search_en":"Water, water intended for human consumption, wastewater Volatile aromatic hydrocarbons (BTX) concentration Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) benzene ethylbenzene toluene o-xylene m+p-xylenes styrene Sum of volatile aromatic hydrocarbons (BTX) (calculated) PN-ISO 11423-1:2002 M","technique_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","test_object_en":"Water, water intended for human consumption, wastewater","search_zh":"水、生活饮用水、污水 挥发性芳香烃（BTX）浓度 顶空气相色谱-质谱法（HS-GC-MS） 苯 乙苯 甲苯 邻二甲苯 间+对二甲苯 苯乙烯 PN-ISO 11423-1:2002 M","test_object_zh":"水、生活饮用水、污水","parameters_zh":[{"name":"苯","range":"(0,25 – 5000) μg/l"},{"name":"乙苯","range":"(0,50 – 5000) μg/l"},{"name":"甲苯","range":"(0,50 – 5000) μg/l"},{"name":"邻二甲苯","range":"(0,50 – 5000) μg/l"},{"name":"间+对二甲苯","range":"(1,0 – 10 000) μg/l"},{"name":"苯乙烯","range":"(0,50 - 5000) μg/l"},{"name":"Suma lotnych węglowodorów aromatycznych (BTX) (z obliczeń)"}],"technique_zh":"顶空气相色谱-质谱法（HS-GC-MS）","methodology_zh":"挥发性芳香烃（BTX）浓度"},{"_id":"6a82c6ff884ede9a1b2c29f9","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie trichlorobenzenów","parameters":[{"name":"1,2,3-trichlorobenzen","range":"(1,2,3-TCB)"},{"name":"Zakres","range":"(0,10 - 4,0) μg/l"},{"name":"1,2,4-trichlorobenzen","range":"(1,2,4-TCB)"},{"name":"(0,10 - 4,0) μg/l"},{"name":"1,3,5-trichlorobenzen","range":"(1,3,5-TCB)"},{"name":"(0,10 - 4,0) μg/l"},{"name":"Suma trichlorobenzenów (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"computed":[],"activity":"Stężenie trichlorobenzenów\nZakres:\n1,2,3-trichlorobenzen (1,2,3-TCB)\nZakres (0,10 - 4,0) μg/l\n1,2,4-trichlorobenzen (1,2,4-TCB)\n(0,10 - 4,0) μg/l\n1,3,5-trichlorobenzen (1,3,5-TCB)\n(0,10 - 4,0) μg/l\nSuma trichlorobenzenów (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN ISO 6468:2002 M","norm_bases":["PN-EN ISO 6468:2002 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie trichlorobenzenów\nZakres:\n1,2,3-trichlorobenzen (1,2,3-TCB)\nZakres (0,10 - 4,0) μg/l\n1,2,4-trichlorobenzen (1,2,4-TCB)\n(0,10 - 4,0) μg/l\n1,3,5-trichlorobenzen (1,3,5-TCB)\n(0,10 - 4,0) μg/l\nSuma trichlorobenzenów (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN ISO 6468:2002 M Woda, woda do spozycia przez ludzi, scieki Stezenie trichlorobenzenow\nZakres:\n1,2,3-trichlorobenzen (1,2,3-TCB)\nZakres (0,10 - 4,0) μg/l\n1,2,4-trichlorobenzen (1,2,4-TCB)\n(0,10 - 4,0) μg/l\n1,3,5-trichlorobenzen (1,3,5-TCB)\n(0,10 - 4,0) μg/l\nSuma trichlorobenzenow (z obliczen)\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN ISO 6468:2002 M","categories":["water"],"row_index":173,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Trichlorobenzene concentration","parameters_en":[{"name":"1,2,3-trichlorobenzene","range":"(1,2,3-TCB)"},{"name":"Range","range":"(0,10 - 4,0) μg/l"},{"name":"1,2,4-trichlorobenzene","range":"(1,2,4-TCB)"},{"name":"(0,10 - 4,0) μg/l"},{"name":"1,3,5-trichlorobenzene","range":"(1,3,5-TCB)"},{"name":"(0,10 - 4,0) μg/l"},{"name":"Sum of trichlorobenzenes (calculated)"}],"search_en":"Water, water intended for human consumption, wastewater Trichlorobenzene concentration Gas chromatography with electron capture detection (GC-ECD) 1,2,3-trichlorobenzene Range 1,2,4-trichlorobenzene (0,10 - 4,0) μg/l 1,3,5-trichlorobenzene (0,10 - 4,0) μg/l Sum of trichlorobenzenes (calculated) PN-EN ISO 6468:2002 M","technique_en":"Gas chromatography with electron capture detection (GC-ECD)","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"1,2,3-三氯苯","range":"(1,2,3-TCB)"},{"name":"范围","range":"(0,10 - 4,0) μg/l"},{"name":"1,2,4-三氯苯","range":"(1,2,4-TCB)"},{"name":"(0,10 - 4,0) μg/l"},{"name":"1,3,5-三氯苯","range":"(1,3,5-TCB)"},{"name":"(0,10 - 4,0) μg/l"},{"name":"三氯苯总量（由计算得出）"}],"search_zh":"水、生活饮用水、污水 气相色谱-电子捕获检测法（GC-ECD） 1,2,3-三氯苯 范围 1,2,4-三氯苯 1,3,5-三氯苯 三氯苯总量（由计算得出） PN-EN ISO 6468:2002 M","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29fa","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie chlorobenzenów","parameters":[{"name":"pentachlorobenzen","range":"(0,010 – 2,0) μg/l"},{"name":"heksachlorobenzen (HCB)"},{"name":"Zakres","range":"(0,010 – 2,0) μg/l"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"computed":[],"activity":"Stężenie chlorobenzenów\nZakres:\npentachlorobenzen (0,010 – 2,0) μg/l\nheksachlorobenzen (HCB)\nZakres (0,010 – 2,0) μg/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN ISO 6468:2002 M","norm_bases":["PN-EN ISO 6468:2002 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie chlorobenzenów\nZakres:\npentachlorobenzen (0,010 – 2,0) μg/l\nheksachlorobenzen (HCB)\nZakres (0,010 – 2,0) μg/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN ISO 6468:2002 M Woda, woda do spozycia przez ludzi, scieki Stezenie chlorobenzenow\nZakres:\npentachlorobenzen (0,010 – 2,0) μg/l\nheksachlorobenzen (HCB)\nZakres (0,010 – 2,0) μg/l\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN ISO 6468:2002 M","categories":["water"],"row_index":174,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorobenzene concentration","parameters_en":[{"name":"pentachlorobenzene","range":"(0,010 – 2,0) μg/l"},{"name":"hexachlorobenzene (HCB)"},{"name":"Range","range":"(0,010 – 2,0) μg/l"}],"search_en":"Water, water intended for human consumption, wastewater Chlorobenzene concentration Gas chromatography with electron capture detection (GC-ECD) pentachlorobenzene hexachlorobenzene (HCB) Range PN-EN ISO 6468:2002 M","technique_en":"Gas chromatography with electron capture detection (GC-ECD)","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"五氯苯","range":"(0,010 – 2,0) μg/l"},{"name":"六氯苯（HCB）"},{"name":"范围","range":"(0,010 – 2,0) μg/l"}],"search_zh":"水、生活饮用水、污水 氯苯类浓度 气相色谱-电子捕获检测法（GC-ECD） 五氯苯 六氯苯（HCB） 范围 PN-EN ISO 6468:2002 M","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"水、生活饮用水、污水","methodology_zh":"氯苯类浓度"},{"_id":"6a82c6ff884ede9a1b2c29fb","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie polichlorowanych bifenyli","parameters":[{"name":"PCB 28","range":"(0,010 – 2,0) µg/l"},{"name":"PCB 52","range":"(0,010 – 2,0) µg/l"},{"name":"PCB 101","range":"(0,010 – 2,0) µg/l"},{"name":"PCB 118","range":"(0,010 – 2,0) µg/l"},{"name":"PCB 138","range":"(0,010 – 2,0) µg/l"},{"name":"PCB 153","range":"(0,010 – 2,0) µg/l"},{"name":"PCB 180","range":"(0,010 – 2,0) µg/l"},{"name":"Suma polichlorowanych bifenyli (PCB) (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"computed":[],"activity":"Stężenie polichlorowanych bifenyli\nZakres:\nPCB 28 (0,010 – 2,0) µg/l\nPCB 52 (0,010 – 2,0) µg/l\nPCB 101 (0,010 – 2,0) µg/l\nPCB 118 (0,010 – 2,0) µg/l\nPCB 138 (0,010 – 2,0) µg/l\nPCB 153 (0,010 – 2,0) µg/l\nPCB 180 (0,010 – 2,0) µg/l\nSuma polichlorowanych bifenyli (PCB) (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN ISO 6468:2002 M","norm_bases":["PN-EN ISO 6468:2002 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie polichlorowanych bifenyli\nZakres:\nPCB 28 (0,010 – 2,0) µg/l\nPCB 52 (0,010 – 2,0) µg/l\nPCB 101 (0,010 – 2,0) µg/l\nPCB 118 (0,010 – 2,0) µg/l\nPCB 138 (0,010 – 2,0) µg/l\nPCB 153 (0,010 – 2,0) µg/l\nPCB 180 (0,010 – 2,0) µg/l\nSuma polichlorowanych bifenyli (PCB) (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN ISO 6468:2002 M Woda, woda do spozycia przez ludzi, scieki Stezenie polichlorowanych bifenyli\nZakres:\nPCB 28 (0,010 – 2,0) µg/l\nPCB 52 (0,010 – 2,0) µg/l\nPCB 101 (0,010 – 2,0) µg/l\nPCB 118 (0,010 – 2,0) µg/l\nPCB 138 (0,010 – 2,0) µg/l\nPCB 153 (0,010 – 2,0) µg/l\nPCB 180 (0,010 – 2,0) µg/l\nSuma polichlorowanych bifenyli (PCB) (z obliczen)\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN ISO 6468:2002 M","categories":["water"],"row_index":175,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polychlorinated biphenyl concentration","parameters_en":[{"name":"PCB 28","range":"(0,010 – 2,0) µg/l"},{"name":"PCB 52","range":"(0,010 – 2,0) µg/l"},{"name":"PCB 101","range":"(0,010 – 2,0) µg/l"},{"name":"PCB 118","range":"(0,010 – 2,0) µg/l"},{"name":"PCB 138","range":"(0,010 – 2,0) µg/l"},{"name":"PCB 153","range":"(0,010 – 2,0) µg/l"},{"name":"PCB 180","range":"(0,010 – 2,0) µg/l"},{"name":"Sum of polychlorinated biphenyls (PCB) (calculated)"}],"search_en":"Water, water intended for human consumption, wastewater Polychlorinated biphenyl concentration Gas chromatography with electron capture detection (GC-ECD) PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 Sum of polychlorinated biphenyls (PCB) (calculated) PN-EN ISO 6468:2002 M","technique_en":"Gas chromatography with electron capture detection (GC-ECD)","test_object_en":"Water, water intended for human consumption, wastewater","search_zh":"水、生活饮用水、污水 气相色谱-电子捕获检测法（GC-ECD） PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 多氯联苯（PCB）总量（由计算得出） PN-EN ISO 6468:2002 M","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"水、生活饮用水、污水","parameters_zh":[{"name":"PCB 28","range":"(0,010 – 2,0) µg/l"},{"name":"PCB 52","range":"(0,010 – 2,0) µg/l"},{"name":"PCB 101","range":"(0,010 – 2,0) µg/l"},{"name":"PCB 118","range":"(0,010 – 2,0) µg/l"},{"name":"PCB 138","range":"(0,010 – 2,0) µg/l"},{"name":"PCB 153","range":"(0,010 – 2,0) µg/l"},{"name":"PCB 180","range":"(0,010 – 2,0) µg/l"},{"name":"多氯联苯（PCB）总量（由计算得出）"}]},{"_id":"6a82c6ff884ede9a1b2c29fc","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie pentachlorofenolu (PCP)","parameters":[{"name":"Zakres","range":"(0,010 – 2,0) µg/l"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"computed":[],"activity":"Stężenie pentachlorofenolu (PCP)\nZakres (0,010 – 2,0) µg/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN 12673:2004 M","norm_bases":["PN-EN 12673:2004 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie pentachlorofenolu (PCP)\nZakres (0,010 – 2,0) µg/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN 12673:2004 M Woda, woda do spozycia przez ludzi, scieki Stezenie pentachlorofenolu (PCP)\nZakres (0,010 – 2,0) µg/l\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN 12673:2004 M","categories":["water"],"row_index":176,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pentachlorophenol (PCP) concentration","parameters_en":[{"name":"Range","range":"(0,010 – 2,0) µg/l"}],"search_en":"Water, water intended for human consumption, wastewater Pentachlorophenol (PCP) concentration Gas chromatography with electron capture detection (GC-ECD) Range PN-EN 12673:2004 M","technique_en":"Gas chromatography with electron capture detection (GC-ECD)","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,010 – 2,0) µg/l"}],"search_zh":"水、生活饮用水、污水 气相色谱-电子捕获检测法（GC-ECD） 范围 PN-EN 12673:2004 M","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29fd","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie 2,4,6-trichlorofenolu","parameters":[{"name":"Zakres","range":"(0,10 – 10) µg/l"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"computed":[],"activity":"Stężenie 2,4,6-trichlorofenolu\nZakres (0,10 – 10) µg/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN 12673:2004 M","norm_bases":["PN-EN 12673:2004 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie 2,4,6-trichlorofenolu\nZakres (0,10 – 10) µg/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN 12673:2004 M Woda, woda do spozycia przez ludzi, scieki Stezenie 2,4,6-trichlorofenolu\nZakres (0,10 – 10) µg/l\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN 12673:2004 M","categories":["water"],"row_index":177,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"2,4,6-trichlorophenol concentration","parameters_en":[{"name":"Range","range":"(0,10 – 10) µg/l"}],"search_en":"Water, water intended for human consumption, wastewater 2,4,6-trichlorophenol concentration Gas chromatography with electron capture detection (GC-ECD) Range PN-EN 12673:2004 M","technique_en":"Gas chromatography with electron capture detection (GC-ECD)","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,10 – 10) µg/l"}],"search_zh":"水、生活饮用水、污水 气相色谱-电子捕获检测法（GC-ECD） 范围 PN-EN 12673:2004 M","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82c6ff884ede9a1b2c29fe","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"acenaften","range":"(0,050 – 0,50) μg/l"},{"name":"antracen","range":"(0,0050 – 0,50) μg/l"},{"name":"benzo(a)antracen","range":"(0,0050 – 0,50) μg/l"},{"name":"benzo(a)piren","range":"(0,0020 – 0,50) µg/l"},{"name":"benzo(b)fluoranten","range":"(0,0050 – 0,50) µg/l"},{"name":"benzo(k)fluoranten","range":"(0,0050 – 0,50) µg/l"},{"name":"benzo(ghi)perylen","range":"(0,0050 – 0,50) µg/l"},{"name":"chryzen","range":"(0,050 – 0,50) µg/l"},{"name":"dibenzo(a,h)antracen","range":"(0,0050 – 0,50) µg/l"},{"name":"fenantren","range":"(0,0050 – 0,50) μg/l"},{"name":"fluoranten","range":"(0,0050 – 0,50) μg/l"},{"name":"fluoren","range":"(0,0050 – 0,50) μg/l"},{"name":"indeno(1,2,3-cd)piren","range":"(0,0050 – 0,50) µg/l"},{"name":"naftalen","range":"(0,050 – 0,50) μg/l"},{"name":"piren","range":"(0,0050 – 0,50) μg/l"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nacenaften (0,050 – 0,50) μg/l\nantracen (0,0050 – 0,50) μg/l\nbenzo(a)antracen (0,0050 – 0,50) μg/l\nbenzo(a)piren (0,0020 – 0,50) µg/l\nbenzo(b)fluoranten (0,0050 – 0,50) µg/l\nbenzo(k)fluoranten (0,0050 – 0,50) µg/l\nbenzo(ghi)perylen (0,0050 – 0,50) µg/l\nchryzen (0,050 – 0,50) µg/l\ndibenzo(a,h)antracen (0,0050 – 0,50) µg/l\nfenantren (0,0050 – 0,50) μg/l\nfluoranten (0,0050 – 0,50) μg/l\nfluoren (0,0050 – 0,50) μg/l\nindeno(1,2,3-cd)piren (0,0050 – 0,50) µg/l\nnaftalen (0,050 – 0,50) μg/l\npiren (0,0050 – 0,50) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PB-160/LF wyd. 7 z dnia 20.01.2022 M","norm_bases":["PB-160/LF wyd. 7 z dnia 20.01.2022 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nacenaften (0,050 – 0,50) μg/l\nantracen (0,0050 – 0,50) μg/l\nbenzo(a)antracen (0,0050 – 0,50) μg/l\nbenzo(a)piren (0,0020 – 0,50) µg/l\nbenzo(b)fluoranten (0,0050 – 0,50) µg/l\nbenzo(k)fluoranten (0,0050 – 0,50) µg/l\nbenzo(ghi)perylen (0,0050 – 0,50) µg/l\nchryzen (0,050 – 0,50) µg/l\ndibenzo(a,h)antracen (0,0050 – 0,50) µg/l\nfenantren (0,0050 – 0,50) μg/l\nfluoranten (0,0050 – 0,50) μg/l\nfluoren (0,0050 – 0,50) μg/l\nindeno(1,2,3-cd)piren (0,0050 – 0,50) µg/l\nnaftalen (0,050 – 0,50) μg/l\npiren (0,0050 – 0,50) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PB-160/LF wyd. 7 z dnia 20.01.2022 M Woda, woda do spozycia przez ludzi, scieki Stezenie wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nacenaften (0,050 – 0,50) μg/l\nantracen (0,0050 – 0,50) μg/l\nbenzo(a)antracen (0,0050 – 0,50) μg/l\nbenzo(a)piren (0,0020 – 0,50) µg/l\nbenzo(b)fluoranten (0,0050 – 0,50) µg/l\nbenzo(k)fluoranten (0,0050 – 0,50) µg/l\nbenzo(ghi)perylen (0,0050 – 0,50) µg/l\nchryzen (0,050 – 0,50) µg/l\ndibenzo(a,h)antracen (0,0050 – 0,50) µg/l\nfenantren (0,0050 – 0,50) μg/l\nfluoranten (0,0050 – 0,50) μg/l\nfluoren (0,0050 – 0,50) μg/l\nindeno(1,2,3-cd)piren (0,0050 – 0,50) µg/l\nnaftalen (0,050 – 0,50) μg/l\npiren (0,0050 – 0,50) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PB-160/LF wyd. 7 z dnia 20.01.2022 M","categories":["water"],"row_index":178,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of polycyclic aromatic hydrocarbons (PAH)","parameters_en":[{"name":"acenaphthene","range":"(0,050 – 0,50) μg/l"},{"name":"anthracene","range":"(0,0050 – 0,50) μg/l"},{"name":"benzo(a)anthracene","range":"(0,0050 – 0,50) μg/l"},{"name":"benzo(a)pyrene","range":"(0,0020 – 0,50) µg/l"},{"name":"benzo(b)fluoranthene","range":"(0,0050 – 0,50) µg/l"},{"name":"benzo(k)fluoranthene","range":"(0,0050 – 0,50) µg/l"},{"name":"benzo(ghi)perylene","range":"(0,0050 – 0,50) µg/l"},{"name":"chrysene","range":"(0,050 – 0,50) µg/l"},{"name":"dibenzo(a,h)anthracene","range":"(0,0050 – 0,50) µg/l"},{"name":"phenanthrene","range":"(0,0050 – 0,50) μg/l"},{"name":"fluoranthene","range":"(0,0050 – 0,50) μg/l"},{"name":"fluorene","range":"(0,0050 – 0,50) μg/l"},{"name":"indeno(1,2,3-cd)pyrene","range":"(0,0050 – 0,50) µg/l"},{"name":"naphthalene","range":"(0,050 – 0,50) μg/l"},{"name":"pyrene","range":"(0,0050 – 0,50) μg/l"}],"search_en":"Water, water intended for human consumption, wastewater Concentration of polycyclic aromatic hydrocarbons (PAH) High-performance liquid chromatography with fluorescence detection (HPLC-FLD) acenaphthene anthracene benzo(a)anthracene benzo(a)pyrene benzo(b)fluoranthene benzo(k)fluoranthene benzo(ghi)perylene chrysene dibenzo(a,h)anthracene phenanthrene fluoranthene fluorene indeno(1,2,3-cd)pyrene naphthalene pyrene PB-160/LF wyd. 7 z dnia 20.01.2022 M","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Water, water intended for human consumption, wastewater","search_zh":"水、生活饮用水、污水 多环芳烃（PAHs）浓度 高效液相色谱-荧光检测法（HPLC-FLD） 苊 蒽 苯并（a）蒽 苯并（a）芘 苯并（b）荧蒽 苯并（k）荧蒽 苯并（ghi）苝 䓛 二苯并（a,h）蒽 菲 荧蒽 芴 茚并(1,2,3-cd)芘 萘 芘 PB-160/LF wyd. 7 z dnia 20.01.2022 M","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"水、生活饮用水、污水","parameters_zh":[{"name":"苊","range":"(0,050 – 0,50) μg/l"},{"name":"蒽","range":"(0,0050 – 0,50) μg/l"},{"name":"苯并（a）蒽","range":"(0,0050 – 0,50) μg/l"},{"name":"苯并（a）芘","range":"(0,0020 – 0,50) µg/l"},{"name":"苯并（b）荧蒽","range":"(0,0050 – 0,50) µg/l"},{"name":"苯并（k）荧蒽","range":"(0,0050 – 0,50) µg/l"},{"name":"苯并（ghi）苝","range":"(0,0050 – 0,50) µg/l"},{"name":"䓛","range":"(0,050 – 0,50) µg/l"},{"name":"二苯并（a,h）蒽","range":"(0,0050 – 0,50) µg/l"},{"name":"菲","range":"(0,0050 – 0,50) μg/l"},{"name":"荧蒽","range":"(0,0050 – 0,50) μg/l"},{"name":"芴","range":"(0,0050 – 0,50) μg/l"},{"name":"茚并(1,2,3-cd)芘","range":"(0,0050 – 0,50) µg/l"},{"name":"萘","range":"(0,050 – 0,50) μg/l"},{"name":"芘","range":"(0,0050 – 0,50) μg/l"}],"methodology_zh":"多环芳烃（PAHs）浓度"},{"_id":"6a82c6ff884ede9a1b2c29ff","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"acenaftylen","range":"(0,050 – 0,50) μg/l"},{"name":"Suma WWA (z obliczeń)"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"computed":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nacenaftylen (0,050 – 0,50) μg/l\nSuma WWA (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"PB-160/LF wyd. 7 z dnia 20.01.2022 M","norm_bases":["PB-160/LF wyd. 7 z dnia 20.01.2022 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nacenaftylen (0,050 – 0,50) μg/l\nSuma WWA (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) PB-160/LF wyd. 7 z dnia 20.01.2022 M Woda, woda do spozycia przez ludzi, scieki Stezenie wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nacenaftylen (0,050 – 0,50) μg/l\nSuma WWA (z obliczen)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) PB-160/LF wyd. 7 z dnia 20.01.2022 M","categories":["water"],"row_index":179,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of polycyclic aromatic hydrocarbons (PAH)","parameters_en":[{"name":"acenaphthylene","range":"(0,050 – 0,50) μg/l"},{"name":"Sum of PAH (calculated)"}],"search_en":"Water, water intended for human consumption, wastewater Concentration of polycyclic aromatic hydrocarbons (PAH) High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) acenaphthylene Sum of PAH (calculated) PB-160/LF wyd. 7 z dnia 20.01.2022 M","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","test_object_en":"Water, water intended for human consumption, wastewater","search_zh":"水、生活饮用水、污水 多环芳烃（PAHs）浓度 高效液相色谱-分光光度检测法（HPLC-UV） 苊烯 多环芳烃总量（计算值） PB-160/LF wyd. 7 z dnia 20.01.2022 M","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）","test_object_zh":"水、生活饮用水、污水","methodology_zh":"多环芳烃（PAHs）浓度","parameters_zh":[{"name":"苊烯","range":"(0,050 – 0,50) μg/l"},{"name":"多环芳烃总量（计算值）"}]},{"_id":"6a82c6ff884ede9a1b2c2a00","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie ftalanów","parameters":[{"name":"ftalan dimetylu","range":"(1,0 - 100) µg/l"},{"name":"ftalan dietylu","range":"(1,0 - 100) µg/l"},{"name":"ftalan di-n-butylu","range":"(1,0 - 100) µg/l"},{"name":"ftalan di-n-oktylu","range":"(1,0 - 100) µg/l"},{"name":"ftalan bis(2-etyloheksylu) DEHP","range":"(1,0 - 100) µg/l"},{"name":"ftalan benzylobutylu","range":"(1,0 - 100) µg/l"},{"name":"Suma ftalanów (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Stężenie ftalanów\nZakres:\nftalan dimetylu (1,0 - 100) µg/l\nftalan dietylu (1,0 - 100) µg/l\nftalan di-n-butylu (1,0 - 100) µg/l\nftalan di-n-oktylu (1,0 - 100) µg/l\nftalan bis(2-etyloheksylu) DEHP (1,0 - 100) µg/l\nftalan benzylobutylu (1,0 - 100) µg/l\nSuma ftalanów (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PN-EN ISO 18856:2006 M","norm_bases":["PN-EN ISO 18856:2006 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie ftalanów\nZakres:\nftalan dimetylu (1,0 - 100) µg/l\nftalan dietylu (1,0 - 100) µg/l\nftalan di-n-butylu (1,0 - 100) µg/l\nftalan di-n-oktylu (1,0 - 100) µg/l\nftalan bis(2-etyloheksylu) DEHP (1,0 - 100) µg/l\nftalan benzylobutylu (1,0 - 100) µg/l\nSuma ftalanów (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PN-EN ISO 18856:2006 M Woda, woda do spozycia przez ludzi, scieki Stezenie ftalanow\nZakres:\nftalan dimetylu (1,0 - 100) µg/l\nftalan dietylu (1,0 - 100) µg/l\nftalan di-n-butylu (1,0 - 100) µg/l\nftalan di-n-oktylu (1,0 - 100) µg/l\nftalan bis(2-etyloheksylu) DEHP (1,0 - 100) µg/l\nftalan benzylobutylu (1,0 - 100) µg/l\nSuma ftalanow (z obliczen)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PN-EN ISO 18856:2006 M","categories":["water"],"row_index":180,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phthalate concentration","parameters_en":[{"name":"dimethyl phthalate","range":"(1,0 - 100) µg/l"},{"name":"diethyl phthalate","range":"(1,0 - 100) µg/l"},{"name":"di-n-butyl phthalate","range":"(1,0 - 100) µg/l"},{"name":"di-n-octyl phthalate","range":"(1,0 - 100) µg/l"},{"name":"ftalan bis(2-etyloheksylu) DEHP","range":"(1,0 - 100) µg/l"},{"name":"benzyl butyl phthalate","range":"(1,0 - 100) µg/l"},{"name":"Sum of phthalates (calculated)"}],"search_en":"Water, water intended for human consumption, wastewater Phthalate concentration Gas chromatography with mass spectrometry detection (GC-MS) dimethyl phthalate diethyl phthalate di-n-butyl phthalate di-n-octyl phthalate benzyl butyl phthalate Sum of phthalates (calculated) PN-EN ISO 18856:2006 M","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Water, water intended for human consumption, wastewater","search_zh":"水、生活饮用水、污水 气相色谱-质谱法（GC-MS） 邻苯二甲酸二甲酯 邻苯二甲酸二乙酯 邻苯二甲酸二正辛酯 邻苯二甲酸酯总量（由计算得出） PN-EN ISO 18856:2006 M","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"水、生活饮用水、污水","parameters_zh":[{"name":"邻苯二甲酸二甲酯","range":"(1,0 - 100) µg/l"},{"name":"邻苯二甲酸二乙酯","range":"(1,0 - 100) µg/l"},{"name":"ftalan di-n-butylu","range":"(1,0 - 100) µg/l"},{"name":"邻苯二甲酸二正辛酯","range":"(1,0 - 100) µg/l"},{"name":"ftalan bis(2-etyloheksylu) DEHP","range":"(1,0 - 100) µg/l"},{"name":"ftalan benzylobutylu","range":"(1,0 - 100) µg/l"},{"name":"邻苯二甲酸酯总量（由计算得出）"}]},{"_id":"6a82c6ff884ede9a1b2c2a01","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"pH","parameters":[{"name":"Zakres","range":"(2,0 – 12,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (2,0 – 12,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09 M","norm_bases":["PN-EN ISO 10390:2022-09 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe pH\nZakres (2,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 M Osady sciekowe pH\nZakres (2,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 M","categories":["water"],"row_index":181,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"(2,0 – 12,0)"}],"search_en":"Sewage sludge pH Potentiometric method Range PN-EN ISO 10390:2022-09 M","technique_en":"Potentiometric method","test_object_en":"Sewage sludge","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(2,0 – 12,0)"}],"search_zh":"污泥 pH 值 电位法 范围 PN-EN ISO 10390:2022-09 M","technique_zh":"电位法","test_object_zh":"污泥"},{"_id":"6a82c6ff884ede9a1b2c2a02","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość suchej masy / zawartość wody","parameters":[{"name":"Zakres","range":"(1,0 – 95,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość suchej masy / zawartość wody\nZakres (1,0 – 95,0) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02 metoda A M","norm_bases":["PN-EN 15934:2013-02 metoda A M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość suchej masy / zawartość wody\nZakres (1,0 – 95,0) %\nMetoda wagowa PN-EN 15934:2013-02 metoda A M Osady sciekowe Zawartosc suchej masy / zawartosc wody\nZakres (1,0 – 95,0) %\nMetoda wagowa PN-EN 15934:2013-02 metoda A M","categories":["water"],"row_index":182,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter content / water content","parameters_en":[{"name":"Range","range":"(1,0 – 95,0) %"}],"search_en":"Sewage sludge Dry matter content / water content Gravimetric method Range PN-EN 15934:2013-02 metoda A M","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(1,0 – 95,0) %"}],"search_zh":"污泥 干物质含量/水分含量 重量法 范围 PN-EN 15934:2013-02 metoda A M","technique_zh":"重量法","test_object_zh":"污泥","methodology_zh":"干物质含量/水分含量"},{"_id":"6a82c6ff884ede9a1b2c2a03","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Straty przy prażeniu suchej masy (LOI) / zawartość substancji organicznych","parameters":[{"name":"Zakres","range":"(10,0 – 85,0) %"},{"name":"Pozostałość po prażeniu / substancje mineralne (z obliczeń)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy (LOI) / zawartość substancji organicznych\nZakres:\nZakres (10,0 – 85,0) %\nPozostałość po prażeniu / substancje mineralne (z obliczeń)\nMetoda wagowa","reference":"PN-EN 15935:2022-01 M","norm_bases":["PN-EN 15935:2022-01 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Straty przy prażeniu suchej masy (LOI) / zawartość substancji organicznych\nZakres:\nZakres (10,0 – 85,0) %\nPozostałość po prażeniu / substancje mineralne (z obliczeń)\nMetoda wagowa PN-EN 15935:2022-01 M Osady sciekowe Straty przy prazeniu suchej masy (LOI) / zawartosc substancji organicznych\nZakres:\nZakres (10,0 – 85,0) %\nPozostalosc po prazeniu / substancje mineralne (z obliczen)\nMetoda wagowa PN-EN 15935:2022-01 M","categories":["water"],"row_index":183,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition of dry matter (LOI) / organic matter content","parameters_en":[{"name":"Range","range":"(10,0 – 85,0) %"},{"name":"Residue on ignition / mineral substances (calculated)"}],"search_en":"Sewage sludge Loss on ignition of dry matter (LOI) / organic matter content Gravimetric method Range Residue on ignition / mineral substances (calculated) PN-EN 15935:2022-01 M","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(10,0 – 85,0) %"},{"name":"灼烧残渣/矿物质（由计算得出）"}],"search_zh":"污泥 干物质烧失量（LOI）/ 有机物质含量 重量法 范围 灼烧残渣/矿物质（由计算得出） PN-EN 15935:2022-01 M","technique_zh":"重量法","test_object_zh":"污泥","methodology_zh":"干物质烧失量（LOI）/ 有机物质含量"},{"_id":"6a82c6ff884ede9a1b2c2a04","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba, grunty, osady ściekowe","methodology":"Zawartość azotu ogólnego","parameters":[{"name":"Zakres","range":"(0,10 – 10) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu ogólnego\nZakres (0,10 – 10) %\nMetoda miareczkowa","reference":"PN-EN 16169:2012 M","norm_bases":["PN-EN 16169:2012 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty, osady ściekowe Zawartość azotu ogólnego\nZakres (0,10 – 10) %\nMetoda miareczkowa PN-EN 16169:2012 M Gleba, grunty, osady sciekowe Zawartosc azotu ogolnego\nZakres (0,10 – 10) %\nMetoda miareczkowa PN-EN 16169:2012 M","categories":["water","environment"],"row_index":184,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen content","parameters_en":[{"name":"Range","range":"(0,10 – 10) %"}],"search_en":"Soil, ground, sewage sludge Total nitrogen content Titrimetric method Range PN-EN 16169:2012 M","technique_en":"Titrimetric method","test_object_en":"Soil, ground, sewage sludge","parameters_zh":[{"name":"范围","range":"(0,10 – 10) %"}],"search_zh":"总氮含量 滴定法 范围 PN-EN 16169:2012 M","technique_zh":"滴定法","methodology_zh":"总氮含量"},{"_id":"6a82c6ff884ede9a1b2c2a05","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba, grunty, osady ściekowe","methodology":"Zawartość azotu amonowego","parameters":[{"name":"Zakres","range":"(0,050 – 2,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu amonowego\nZakres (0,050 – 2,0) %\nMetoda miareczkowa","reference":"PB-292/LF wyd. 2 z dnia 20.01.2022 M","norm_bases":["PB-292/LF wyd. 2 z dnia 20.01.2022 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty, osady ściekowe Zawartość azotu amonowego\nZakres (0,050 – 2,0) %\nMetoda miareczkowa PB-292/LF wyd. 2 z dnia 20.01.2022 M Gleba, grunty, osady sciekowe Zawartosc azotu amonowego\nZakres (0,050 – 2,0) %\nMetoda miareczkowa PB-292/LF wyd. 2 z dnia 20.01.2022 M","categories":["water","environment"],"row_index":185,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen content","parameters_en":[{"name":"Range","range":"(0,050 – 2,0) %"}],"search_en":"Soil, ground, sewage sludge Ammonium nitrogen content Titrimetric method Range PB-292/LF wyd. 2 z dnia 20.01.2022 M","technique_en":"Titrimetric method","test_object_en":"Soil, ground, sewage sludge","parameters_zh":[{"name":"范围","range":"(0,050 – 2,0) %"}],"search_zh":"氨氮含量 滴定法 范围 PB-292/LF wyd. 2 z dnia 20.01.2022 M","technique_zh":"滴定法","methodology_zh":"氨氮含量"},{"_id":"6a82c6ff884ede9a1b2c2a06","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"pH w H2O; pH w KCl","parameters":[{"name":"Zakres","range":"(2,0 – 12,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH w H2O; pH w KCl\nZakres (2,0 – 12,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09 M","norm_bases":["PN-EN ISO 10390:2022-09 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty pH w H2O; pH w KCl\nZakres (2,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 M Gleba, grunty pH w H2O; pH w KCl\nZakres (2,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 M","categories":["environment"],"row_index":186,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(2,0 – 12,0)"}],"search_en":"Soil, ground Potentiometric method Range PN-EN ISO 10390:2022-09 M","technique_en":"Potentiometric method","test_object_en":"Soil, ground","parameters_zh":[{"name":"范围","range":"(2,0 – 12,0)"}],"search_zh":"土壤、土体 电位法 范围 PN-EN ISO 10390:2022-09 M","technique_zh":"电位法","test_object_zh":"土壤、土体"},{"_id":"6a82c6ff884ede9a1b2c2a07","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Zawartość suchej masy/zawartość wody","parameters":[{"name":"Zakres","range":"(1,0 – 99,5)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość suchej masy/zawartość wody\nZakres (1,0 – 99,5)%\nMetoda wagowa","reference":"PN-ISO 11465:1999 M","norm_bases":["PN-ISO 11465:1999 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Zawartość suchej masy/zawartość wody\nZakres (1,0 – 99,5)%\nMetoda wagowa PN-ISO 11465:1999 M Gleba, grunty Zawartosc suchej masy/zawartosc wody\nZakres (1,0 – 99,5)%\nMetoda wagowa PN-ISO 11465:1999 M","categories":["water","environment"],"row_index":187,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter content/water content","parameters_en":[{"name":"Range","range":"(1,0 – 99,5)%"}],"search_en":"Soil, ground Dry matter content/water content Gravimetric method Range PN-ISO 11465:1999 M","technique_en":"Gravimetric method","test_object_en":"Soil, ground","parameters_zh":[{"name":"范围","range":"(1,0 – 99,5)%"}],"search_zh":"土壤、土体 重量法 范围 PN-ISO 11465:1999 M","technique_zh":"重量法","test_object_zh":"土壤、土体"},{"_id":"6a82c6ff884ede9a1b2c2a08","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Zawartość suchej masy/zawartość wody","parameters":[{"name":"Zakres","range":"(1,0 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość suchej masy/zawartość wody\nZakres (1,0 – 99,0) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02 metoda A M","norm_bases":["PN-EN 15934:2013-02 metoda A M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Zawartość suchej masy/zawartość wody\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15934:2013-02 metoda A M Gleba, grunty Zawartosc suchej masy/zawartosc wody\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15934:2013-02 metoda A M","categories":["water","environment"],"row_index":188,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter content/water content","parameters_en":[{"name":"Range","range":"(1,0 – 99,0) %"}],"search_en":"Soil, ground Dry matter content/water content Gravimetric method Range PN-EN 15934:2013-02 metoda A M","technique_en":"Gravimetric method","test_object_en":"Soil, ground","parameters_zh":[{"name":"范围","range":"(1,0 – 99,0) %"}],"search_zh":"土壤、土体 重量法 范围 PN-EN 15934:2013-02 metoda A M","technique_zh":"重量法","test_object_zh":"土壤、土体"},{"_id":"6a82c6ff884ede9a1b2c2a09","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Straty przy prażeniu suchej masy (LOI) / zawartość substancji organicznych","parameters":[{"name":"Zakres","range":"(1,0 – 30,0) %"},{"name":"Pozostałość po prażeniu / substancje mineralne (z obliczeń)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy (LOI) / zawartość substancji organicznych\nZakres:\nZakres (1,0 – 30,0) %\nPozostałość po prażeniu / substancje mineralne (z obliczeń)\nMetoda wagowa","reference":"PN-EN 15935:2022-01 M","norm_bases":["PN-EN 15935:2022-01 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Straty przy prażeniu suchej masy (LOI) / zawartość substancji organicznych\nZakres:\nZakres (1,0 – 30,0) %\nPozostałość po prażeniu / substancje mineralne (z obliczeń)\nMetoda wagowa PN-EN 15935:2022-01 M Gleba, grunty Straty przy prazeniu suchej masy (LOI) / zawartosc substancji organicznych\nZakres:\nZakres (1,0 – 30,0) %\nPozostalosc po prazeniu / substancje mineralne (z obliczen)\nMetoda wagowa PN-EN 15935:2022-01 M","categories":["environment"],"row_index":189,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition of dry matter (LOI) / organic matter content","parameters_en":[{"name":"Range","range":"(1,0 – 30,0) %"},{"name":"Residue on ignition / mineral substances (calculated)"}],"search_en":"Soil, ground Loss on ignition of dry matter (LOI) / organic matter content Gravimetric method Range Residue on ignition / mineral substances (calculated) PN-EN 15935:2022-01 M","technique_en":"Gravimetric method","test_object_en":"Soil, ground","parameters_zh":[{"name":"范围","range":"(1,0 – 30,0) %"},{"name":"灼烧残渣/矿物质（由计算得出）"}],"search_zh":"土壤、土体 干物质烧失量（LOI）/ 有机物质含量 重量法 范围 灼烧残渣/矿物质（由计算得出） PN-EN 15935:2022-01 M","technique_zh":"重量法","test_object_zh":"土壤、土体","methodology_zh":"干物质烧失量（LOI）/ 有机物质含量"},{"_id":"6a82c6ff884ede9a1b2c2a0a","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Kwasowość hydrolityczna","parameters":[{"name":"Zakres","range":"(0,75 – 15) cmol/kg"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Kwasowość hydrolityczna\nZakres (0,75 – 15) cmol/kg\nMetoda miareczkowania potencjometrycznego","reference":"PB-328/LF wyd. 1 z dnia 14.01.2025 M","norm_bases":["PB-328/LF wyd. 1 z dnia 14.01.2025 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Kwasowość hydrolityczna\nZakres (0,75 – 15) cmol/kg\nMetoda miareczkowania potencjometrycznego PB-328/LF wyd. 1 z dnia 14.01.2025 M Gleba, grunty Kwasowosc hydrolityczna\nZakres (0,75 – 15) cmol/kg\nMetoda miareczkowania potencjometrycznego PB-328/LF wyd. 1 z dnia 14.01.2025 M","categories":["environment"],"row_index":190,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrolytic acidity","parameters_en":[{"name":"Range","range":"(0,75 – 15) cmol/kg"}],"search_en":"Soil, ground Hydrolytic acidity Potentiometric titration method Range PB-328/LF wyd. 1 z dnia 14.01.2025 M","technique_en":"Potentiometric titration method","test_object_en":"Soil, ground","parameters_zh":[{"name":"范围","range":"(0,75 – 15) cmol/kg"}],"search_zh":"土壤、土体 水解酸度 电位滴定法 范围 PB-328/LF wyd. 1 z dnia 14.01.2025 M","technique_zh":"电位滴定法","test_object_zh":"土壤、土体","methodology_zh":"水解酸度"},{"_id":"6a82c6ff884ede9a1b2c2a0b","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba mineralna","methodology":"Zawartość przyswajalnego fosforu","parameters":[{"name":"Zakres","range":"(1,0 – 50) mg/100g P2O5"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość przyswajalnego fosforu\nZakres (1,0 – 50) mg/100g P2O5\nMetoda spektrofotometryczna","reference":"PN-R-04023:1996 M","norm_bases":["PN-R-04023:1996 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba mineralna Zawartość przyswajalnego fosforu\nZakres (1,0 – 50) mg/100g P2O5\nMetoda spektrofotometryczna PN-R-04023:1996 M Gleba mineralna Zawartosc przyswajalnego fosforu\nZakres (1,0 – 50) mg/100g P2O5\nMetoda spektrofotometryczna PN-R-04023:1996 M","categories":["environment"],"row_index":191,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Available phosphorus content","parameters_en":[{"name":"Range","range":"(1,0 – 50) mg/100g P2O5"}],"search_en":"Mineral soil Available phosphorus content Spectrophotometric method Range PN-R-04023:1996 M","technique_en":"Spectrophotometric method","test_object_en":"Mineral soil","parameters_zh":[{"name":"范围","range":"(1,0 – 50) mg/100g P2O5"}],"search_zh":"矿质土壤 有效磷含量 分光光度法 范围 PN-R-04023:1996 M","technique_zh":"分光光度法","test_object_zh":"矿质土壤","methodology_zh":"有效磷含量"},{"_id":"6a82c6ff884ede9a1b2c2a0c","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba organiczna","methodology":"Zawartość przyswajalnego fosforu","parameters":[{"name":"Zakres","range":"(12,5 – 250) mg/100g P2O5"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość przyswajalnego fosforu\nZakres (12,5 – 250) mg/100g P2O5\nMetoda spektrofotometryczna","reference":"PN-R-04024:1997 M","norm_bases":["PN-R-04024:1997 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba organiczna Zawartość przyswajalnego fosforu\nZakres (12,5 – 250) mg/100g P2O5\nMetoda spektrofotometryczna PN-R-04024:1997 M Gleba organiczna Zawartosc przyswajalnego fosforu\nZakres (12,5 – 250) mg/100g P2O5\nMetoda spektrofotometryczna PN-R-04024:1997 M","categories":["environment"],"row_index":192,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Available phosphorus content","parameters_en":[{"name":"Range","range":"(12,5 – 250) mg/100g P2O5"}],"search_en":"Organic soil Available phosphorus content Spectrophotometric method Range PN-R-04024:1997 M","technique_en":"Spectrophotometric method","test_object_en":"Organic soil","parameters_zh":[{"name":"范围","range":"(12,5 – 250) mg/100g P2O5"}],"search_zh":"有机土壤 有效磷含量 分光光度法 范围 PN-R-04024:1997 M","technique_zh":"分光光度法","methodology_zh":"有效磷含量","test_object_zh":"有机土壤"},{"_id":"6a82c6ff884ede9a1b2c2a0d","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba mineralna, gleba organiczna","methodology":"Zawartość przyswajalnych pierwiastków","parameters":[{"name":"fosfor","range":"(2,50 – 1000) mg/kg"},{"name":"magnez","range":"(0,50 – 1000) mg/kg"},{"name":"potas","range":"(50 – 5000) mg/kg"},{"name":"wapń","range":"(0,50 – 10 000) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość przyswajalnych pierwiastków\nZakres:\nfosfor (2,50 – 1000) mg/kg\nmagnez (0,50 – 1000) mg/kg\npotas (50 – 5000) mg/kg\nwapń (0,50 – 10 000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009 | PB-49/LF wyd. 3 z dnia 20.01.2022 M","norm_bases":["PN-EN ISO 11885:2009","PB-49/LF wyd. 3 z dnia 20.01.2022 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba mineralna, gleba organiczna Zawartość przyswajalnych pierwiastków\nZakres:\nfosfor (2,50 – 1000) mg/kg\nmagnez (0,50 – 1000) mg/kg\npotas (50 – 5000) mg/kg\nwapń (0,50 – 10 000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 | PB-49/LF wyd. 3 z dnia 20.01.2022 M Gleba mineralna, gleba organiczna Zawartosc przyswajalnych pierwiastkow\nZakres:\nfosfor (2,50 – 1000) mg/kg\nmagnez (0,50 – 1000) mg/kg\npotas (50 – 5000) mg/kg\nwapn (0,50 – 10 000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009 | PB-49/LF wyd. 3 z dnia 20.01.2022 M","categories":["environment"],"row_index":193,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Available element content","parameters_en":[{"name":"phosphorus","range":"(2,50 – 1000) mg/kg"},{"name":"magnesium","range":"(0,50 – 1000) mg/kg"},{"name":"potassium","range":"(50 – 5000) mg/kg"},{"name":"calcium","range":"(0,50 – 10 000) mg/kg"}],"search_en":"Mineral soil, organic soil Available element content Inductively coupled plasma optical emission spectrometry (ICP-OES) phosphorus magnesium potassium calcium PN-EN ISO 11885:2009 | PB-49/LF wyd. 3 z dnia 20.01.2022 M","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Mineral soil, organic soil","search_zh":"速效元素含量 电感耦合等离子体原子发射光谱法（ICP-OES） 磷 镁 钾 钙 PN-EN ISO 11885:2009 | PB-49/LF wyd. 3 z dnia 20.01.2022 M","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","parameters_zh":[{"name":"磷","range":"(2,50 – 1000) mg/kg"},{"name":"镁","range":"(0,50 – 1000) mg/kg"},{"name":"钾","range":"(50 – 5000) mg/kg"},{"name":"钙","range":"(0,50 – 10 000) mg/kg"}],"methodology_zh":"速效元素含量"},{"_id":"6a82c6ff884ede9a1b2c2a0e","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość cyjanków wolnych, ogólnych","parameters":[{"name":"Zakres","range":"(1,0 - 100) mg/kg"},{"name":"Zawartość cyjanków związanych (z obliczeń)"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Zawartość cyjanków wolnych, ogólnych\nZakres:\nZakres (1,0 - 100) mg/kg\nZawartość cyjanków związanych (z obliczeń)\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 17380:2013-08 M","norm_bases":["PN-EN ISO 17380:2013-08 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość cyjanków wolnych, ogólnych\nZakres:\nZakres (1,0 - 100) mg/kg\nZawartość cyjanków związanych (z obliczeń)\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 17380:2013-08 M Gleba Zawartosc cyjankow wolnych, ogolnych\nZakres:\nZakres (1,0 - 100) mg/kg\nZawartosc cyjankow zwiazanych (z obliczen)\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 17380:2013-08 M","categories":["environment"],"row_index":194,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free and total cyanide content","parameters_en":[{"name":"Range","range":"(1,0 - 100) mg/kg"},{"name":"Combined cyanide content (calculated)"}],"search_en":"Soil Free and total cyanide content Continuous flow analysis (CFA) with spectrophotometric detection Range Combined cyanide content (calculated) PN-EN ISO 17380:2013-08 M","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(1,0 - 100) mg/kg"},{"name":"络合氰化物含量（由计算得出）"}],"search_zh":"土壤 连续流动分析（CFA）分光光度检测法 范围 络合氰化物含量（由计算得出） PN-EN ISO 17380:2013-08 M","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"土壤"},{"_id":"6a82c6ff884ede9a1b2c2a0f","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość lotnych jednopierścieniowych węglowodorów aromatycznych","parameters":[{"name":"benzen","range":"(0,020 – 15) mg/kg"},{"name":"etylobenzen","range":"(0,020 – 15) mg/kg"},{"name":"toluen","range":"(0,020 – 15) mg/kg"},{"name":"o-ksylen","range":"(0,020 – 15) mg/kg"},{"name":"m+p-ksyleny","range":"(0,040 – 30) mg/kg"},{"name":"styren","range":"(0,020 - 15) mg/kg"},{"name":"Suma jednopierścieniowych węglowodorów aromatycznych (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)"],"computed":[],"activity":"Zawartość lotnych jednopierścieniowych węglowodorów aromatycznych\nZakres:\nbenzen (0,020 – 15) mg/kg\netylobenzen (0,020 – 15) mg/kg\ntoluen (0,020 – 15) mg/kg\no-ksylen (0,020 – 15) mg/kg\nm+p-ksyleny (0,040 – 30) mg/kg\nstyren (0,020 - 15) mg/kg\nSuma jednopierścieniowych węglowodorów aromatycznych (z obliczeń)\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","reference":"PN-EN ISO 22155:2016-07 M","norm_bases":["PN-EN ISO 22155:2016-07 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość lotnych jednopierścieniowych węglowodorów aromatycznych\nZakres:\nbenzen (0,020 – 15) mg/kg\netylobenzen (0,020 – 15) mg/kg\ntoluen (0,020 – 15) mg/kg\no-ksylen (0,020 – 15) mg/kg\nm+p-ksyleny (0,040 – 30) mg/kg\nstyren (0,020 - 15) mg/kg\nSuma jednopierścieniowych węglowodorów aromatycznych (z obliczeń)\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) PN-EN ISO 22155:2016-07 M Gleba Zawartosc lotnych jednopierscieniowych weglowodorow aromatycznych\nZakres:\nbenzen (0,020 – 15) mg/kg\netylobenzen (0,020 – 15) mg/kg\ntoluen (0,020 – 15) mg/kg\no-ksylen (0,020 – 15) mg/kg\nm+p-ksyleny (0,040 – 30) mg/kg\nstyren (0,020 - 15) mg/kg\nSuma jednopierscieniowych weglowodorow aromatycznych (z obliczen)\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) PN-EN ISO 22155:2016-07 M","categories":["environment"],"row_index":195,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of volatile monocyclic aromatic hydrocarbons","parameters_en":[{"name":"benzene","range":"(0,020 – 15) mg/kg"},{"name":"ethylbenzene","range":"(0,020 – 15) mg/kg"},{"name":"toluene","range":"(0,020 – 15) mg/kg"},{"name":"o-xylene","range":"(0,020 – 15) mg/kg"},{"name":"m+p-xylenes","range":"(0,040 – 30) mg/kg"},{"name":"styrene","range":"(0,020 - 15) mg/kg"},{"name":"Sum of monocyclic aromatic hydrocarbons (calculated)"}],"search_en":"Soil Content of volatile monocyclic aromatic hydrocarbons Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) benzene ethylbenzene toluene o-xylene m+p-xylenes styrene Sum of monocyclic aromatic hydrocarbons (calculated) PN-EN ISO 22155:2016-07 M","technique_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","test_object_en":"Soil","search_zh":"土壤 顶空气相色谱-质谱法（HS-GC-MS） 苯 乙苯 甲苯 邻二甲苯 间+对二甲苯 苯乙烯 PN-EN ISO 22155:2016-07 M","test_object_zh":"土壤","parameters_zh":[{"name":"苯","range":"(0,020 – 15) mg/kg"},{"name":"乙苯","range":"(0,020 – 15) mg/kg"},{"name":"甲苯","range":"(0,020 – 15) mg/kg"},{"name":"邻二甲苯","range":"(0,020 – 15) mg/kg"},{"name":"间+对二甲苯","range":"(0,040 – 30) mg/kg"},{"name":"苯乙烯","range":"(0,020 - 15) mg/kg"},{"name":"Suma jednopierścieniowych węglowodorów aromatycznych (z obliczeń)"}],"technique_zh":"顶空气相色谱-质谱法（HS-GC-MS）"},{"_id":"6a82c6ff884ede9a1b2c2a10","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba","methodology":"Suma węglowodorów C6-C12, składników frakcji benzyn","parameters":[{"name":"Zakres","range":"(1,0 – 1000) mg/kg"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)"],"computed":[],"activity":"Suma węglowodorów C6-C12, składników frakcji benzyn\nZakres (1,0 – 1000) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","reference":"PB-200/LF wyd. 6 z dnia 20.01.2022 M","norm_bases":["PB-200/LF wyd. 6 z dnia 20.01.2022 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Suma węglowodorów C6-C12, składników frakcji benzyn\nZakres (1,0 – 1000) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID) PB-200/LF wyd. 6 z dnia 20.01.2022 M Gleba Suma weglowodorow C6-C12, skladnikow frakcji benzyn\nZakres (1,0 – 1000) mg/kg\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja plomieniowo-jonizacyjna (HS-GC-FID) PB-200/LF wyd. 6 z dnia 20.01.2022 M","categories":["environment"],"row_index":196,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of hydrocarbons C6-C12, components of the gasoline fraction","parameters_en":[{"name":"Range","range":"(1,0 – 1000) mg/kg"}],"search_en":"Soil Sum of hydrocarbons C6-C12, components of the gasoline fraction Headspace gas chromatography with flame ionization detection (HS-GC-FID) Range PB-200/LF wyd. 6 z dnia 20.01.2022 M","technique_en":"Headspace gas chromatography with flame ionization detection (HS-GC-FID)","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(1,0 – 1000) mg/kg"}],"search_zh":"土壤 顶空气相色谱-火焰离子化检测法（HS-GC-FID） 范围 PB-200/LF wyd. 6 z dnia 20.01.2022 M","test_object_zh":"土壤","technique_zh":"顶空气相色谱-火焰离子化检测法（HS-GC-FID）"},{"_id":"6a82c6ff884ede9a1b2c2a11","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość polichlorowanych bifenyli","parameters":[{"name":"PCB 28","range":"(0,020 – 2,0) mg/kg"},{"name":"PCB 52","range":"(0,020 – 2,0) mg/kg"},{"name":"PCB 101","range":"(0,020 – 2,0) mg/kg"},{"name":"PCB 118","range":"(0,020 – 2,0) mg/kg"},{"name":"PCB 138","range":"(0,020 – 2,0) mg/kg"},{"name":"PCB 153","range":"(0,020 – 2,0) mg/kg"},{"name":"PCB 180","range":"(0,020 – 2,0) mg/kg"},{"name":"Suma polichlorowanych bifenyli (PCB) (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"computed":[],"activity":"Zawartość polichlorowanych bifenyli\nZakres:\nPCB 28 (0,020 – 2,0) mg/kg\nPCB 52 (0,020 – 2,0) mg/kg\nPCB 101 (0,020 – 2,0) mg/kg\nPCB 118 (0,020 – 2,0) mg/kg\nPCB 138 (0,020 – 2,0) mg/kg\nPCB 153 (0,020 – 2,0) mg/kg\nPCB 180 (0,020 – 2,0) mg/kg\nSuma polichlorowanych bifenyli (PCB) (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-ISO 10382:2007 M","norm_bases":["PN-ISO 10382:2007 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość polichlorowanych bifenyli\nZakres:\nPCB 28 (0,020 – 2,0) mg/kg\nPCB 52 (0,020 – 2,0) mg/kg\nPCB 101 (0,020 – 2,0) mg/kg\nPCB 118 (0,020 – 2,0) mg/kg\nPCB 138 (0,020 – 2,0) mg/kg\nPCB 153 (0,020 – 2,0) mg/kg\nPCB 180 (0,020 – 2,0) mg/kg\nSuma polichlorowanych bifenyli (PCB) (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-ISO 10382:2007 M Gleba Zawartosc polichlorowanych bifenyli\nZakres:\nPCB 28 (0,020 – 2,0) mg/kg\nPCB 52 (0,020 – 2,0) mg/kg\nPCB 101 (0,020 – 2,0) mg/kg\nPCB 118 (0,020 – 2,0) mg/kg\nPCB 138 (0,020 – 2,0) mg/kg\nPCB 153 (0,020 – 2,0) mg/kg\nPCB 180 (0,020 – 2,0) mg/kg\nSuma polichlorowanych bifenyli (PCB) (z obliczen)\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-ISO 10382:2007 M","categories":["environment"],"row_index":197,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polychlorinated biphenyl content","parameters_en":[{"name":"PCB 28","range":"(0,020 – 2,0) mg/kg"},{"name":"PCB 52","range":"(0,020 – 2,0) mg/kg"},{"name":"PCB 101","range":"(0,020 – 2,0) mg/kg"},{"name":"PCB 118","range":"(0,020 – 2,0) mg/kg"},{"name":"PCB 138","range":"(0,020 – 2,0) mg/kg"},{"name":"PCB 153","range":"(0,020 – 2,0) mg/kg"},{"name":"PCB 180","range":"(0,020 – 2,0) mg/kg"},{"name":"Sum of polychlorinated biphenyls (PCB) (calculated)"}],"search_en":"Soil Polychlorinated biphenyl content Gas chromatography with electron capture detection (GC-ECD) PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 Sum of polychlorinated biphenyls (PCB) (calculated) PN-ISO 10382:2007 M","technique_en":"Gas chromatography with electron capture detection (GC-ECD)","test_object_en":"Soil","search_zh":"土壤 多氯联苯含量 气相色谱-电子捕获检测法（GC-ECD） PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 多氯联苯（PCB）总量（由计算得出） PN-ISO 10382:2007 M","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"土壤","parameters_zh":[{"name":"PCB 28","range":"(0,020 – 2,0) mg/kg"},{"name":"PCB 52","range":"(0,020 – 2,0) mg/kg"},{"name":"PCB 101","range":"(0,020 – 2,0) mg/kg"},{"name":"PCB 118","range":"(0,020 – 2,0) mg/kg"},{"name":"PCB 138","range":"(0,020 – 2,0) mg/kg"},{"name":"PCB 153","range":"(0,020 – 2,0) mg/kg"},{"name":"PCB 180","range":"(0,020 – 2,0) mg/kg"},{"name":"多氯联苯（PCB）总量（由计算得出）"}],"methodology_zh":"多氯联苯含量"},{"_id":"6a82c6ff884ede9a1b2c2a12","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"acenaften","range":"(0,020 – 100) mg/kg"},{"name":"acenaftylen","range":"(0,020 – 100) mg/kg"},{"name":"antracen","range":"(0,020 – 100) mg/kg"},{"name":"benzo(a)antracen","range":"(0,020 – 100) mg/kg"},{"name":"benzo(a)piren","range":"(0,020 – 100) mg/kg"},{"name":"benzo(b)fluoranten","range":"(0,020 – 100) mg/kg"},{"name":"benzo(k)fluoranten","range":"(0,020 – 100) mg/kg"},{"name":"benzo(ghi)perylen","range":"(0,020 – 100) mg/kg"},{"name":"chryzen","range":"(0,020 – 100) mg/kg"},{"name":"dibenzo(a,h)antracen","range":"(0,020 – 100) mg/kg"},{"name":"fenantren","range":"(0,020 – 100) mg/kg"},{"name":"fluoranten","range":"(0,020 – 100) mg/kg"},{"name":"fluoren","range":"(0,020 – 100) mg/kg"},{"name":"indeno(1,2,3-cd)piren","range":"(0,020 – 100) mg/kg"},{"name":"naftalen","range":"(0,020 – 100) mg/kg"},{"name":"piren","range":"(0,020 – 100) mg/kg"},{"name":"Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nacenaften (0,020 – 100) mg/kg\nacenaftylen (0,020 – 100) mg/kg\nantracen (0,020 – 100) mg/kg\nbenzo(a)antracen (0,020 – 100) mg/kg\nbenzo(a)piren (0,020 – 100) mg/kg\nbenzo(b)fluoranten (0,020 – 100) mg/kg\nbenzo(k)fluoranten (0,020 – 100) mg/kg\nbenzo(ghi)perylen (0,020 – 100) mg/kg\nchryzen (0,020 – 100) mg/kg\ndibenzo(a,h)antracen (0,020 – 100) mg/kg\nfenantren (0,020 – 100) mg/kg\nfluoranten (0,020 – 100) mg/kg\nfluoren (0,020 – 100) mg/kg\nindeno(1,2,3-cd)piren (0,020 – 100) mg/kg\nnaftalen (0,020 – 100) mg/kg\npiren (0,020 – 100) mg/kg\nSuma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PN-ISO 18287:2008 M","norm_bases":["PN-ISO 18287:2008 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nacenaften (0,020 – 100) mg/kg\nacenaftylen (0,020 – 100) mg/kg\nantracen (0,020 – 100) mg/kg\nbenzo(a)antracen (0,020 – 100) mg/kg\nbenzo(a)piren (0,020 – 100) mg/kg\nbenzo(b)fluoranten (0,020 – 100) mg/kg\nbenzo(k)fluoranten (0,020 – 100) mg/kg\nbenzo(ghi)perylen (0,020 – 100) mg/kg\nchryzen (0,020 – 100) mg/kg\ndibenzo(a,h)antracen (0,020 – 100) mg/kg\nfenantren (0,020 – 100) mg/kg\nfluoranten (0,020 – 100) mg/kg\nfluoren (0,020 – 100) mg/kg\nindeno(1,2,3-cd)piren (0,020 – 100) mg/kg\nnaftalen (0,020 – 100) mg/kg\npiren (0,020 – 100) mg/kg\nSuma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PN-ISO 18287:2008 M Gleba Zawartosc wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nacenaften (0,020 – 100) mg/kg\nacenaftylen (0,020 – 100) mg/kg\nantracen (0,020 – 100) mg/kg\nbenzo(a)antracen (0,020 – 100) mg/kg\nbenzo(a)piren (0,020 – 100) mg/kg\nbenzo(b)fluoranten (0,020 – 100) mg/kg\nbenzo(k)fluoranten (0,020 – 100) mg/kg\nbenzo(ghi)perylen (0,020 – 100) mg/kg\nchryzen (0,020 – 100) mg/kg\ndibenzo(a,h)antracen (0,020 – 100) mg/kg\nfenantren (0,020 – 100) mg/kg\nfluoranten (0,020 – 100) mg/kg\nfluoren (0,020 – 100) mg/kg\nindeno(1,2,3-cd)piren (0,020 – 100) mg/kg\nnaftalen (0,020 – 100) mg/kg\npiren (0,020 – 100) mg/kg\nSuma wielopierscieniowych weglowodorow aromatycznych (WWA) (z obliczen)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PN-ISO 18287:2008 M","categories":["environment"],"row_index":198,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polycyclic aromatic hydrocarbons (PAH) content","parameters_en":[{"name":"acenaphthene","range":"(0,020 – 100) mg/kg"},{"name":"acenaphthylene","range":"(0,020 – 100) mg/kg"},{"name":"anthracene","range":"(0,020 – 100) mg/kg"},{"name":"benzo(a)anthracene","range":"(0,020 – 100) mg/kg"},{"name":"benzo(a)pyrene","range":"(0,020 – 100) mg/kg"},{"name":"benzo(b)fluoranthene","range":"(0,020 – 100) mg/kg"},{"name":"benzo(k)fluoranthene","range":"(0,020 – 100) mg/kg"},{"name":"benzo(ghi)perylene","range":"(0,020 – 100) mg/kg"},{"name":"chrysene","range":"(0,020 – 100) mg/kg"},{"name":"dibenzo(a,h)anthracene","range":"(0,020 – 100) mg/kg"},{"name":"phenanthrene","range":"(0,020 – 100) mg/kg"},{"name":"fluoranthene","range":"(0,020 – 100) mg/kg"},{"name":"fluorene","range":"(0,020 – 100) mg/kg"},{"name":"indeno(1,2,3-cd)pyrene","range":"(0,020 – 100) mg/kg"},{"name":"naphthalene","range":"(0,020 – 100) mg/kg"},{"name":"pyrene","range":"(0,020 – 100) mg/kg"},{"name":"Sum of polycyclic aromatic hydrocarbons (PAH) (calculated)"}],"search_en":"Soil Polycyclic aromatic hydrocarbons (PAH) content Gas chromatography with mass spectrometry detection (GC-MS) acenaphthene acenaphthylene anthracene benzo(a)anthracene benzo(a)pyrene benzo(b)fluoranthene benzo(k)fluoranthene benzo(ghi)perylene chrysene dibenzo(a,h)anthracene phenanthrene fluoranthene fluorene indeno(1,2,3-cd)pyrene naphthalene pyrene Sum of polycyclic aromatic hydrocarbons (PAH) (calculated) PN-ISO 18287:2008 M","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Soil","search_zh":"土壤 多环芳烃（PAHs）含量 气相色谱-质谱法（GC-MS） 苊 苊烯 蒽 苯并（a）蒽 苯并（a）芘 苯并（b）荧蒽 苯并（k）荧蒽 苯并（ghi）苝 䓛 二苯并（a,h）蒽 菲 荧蒽 芴 茚并(1,2,3-cd)芘 萘 芘 多环芳烃（PAH）总量（由计算得出） PN-ISO 18287:2008 M","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"土壤","parameters_zh":[{"name":"苊","range":"(0,020 – 100) mg/kg"},{"name":"苊烯","range":"(0,020 – 100) mg/kg"},{"name":"蒽","range":"(0,020 – 100) mg/kg"},{"name":"苯并（a）蒽","range":"(0,020 – 100) mg/kg"},{"name":"苯并（a）芘","range":"(0,020 – 100) mg/kg"},{"name":"苯并（b）荧蒽","range":"(0,020 – 100) mg/kg"},{"name":"苯并（k）荧蒽","range":"(0,020 – 100) mg/kg"},{"name":"苯并（ghi）苝","range":"(0,020 – 100) mg/kg"},{"name":"䓛","range":"(0,020 – 100) mg/kg"},{"name":"二苯并（a,h）蒽","range":"(0,020 – 100) mg/kg"},{"name":"菲","range":"(0,020 – 100) mg/kg"},{"name":"荧蒽","range":"(0,020 – 100) mg/kg"},{"name":"芴","range":"(0,020 – 100) mg/kg"},{"name":"茚并(1,2,3-cd)芘","range":"(0,020 – 100) mg/kg"},{"name":"萘","range":"(0,020 – 100) mg/kg"},{"name":"芘","range":"(0,020 – 100) mg/kg"},{"name":"多环芳烃（PAH）总量（由计算得出）"}],"methodology_zh":"多环芳烃（PAHs）含量"},{"_id":"6a82c6ff884ede9a1b2c2a13","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość chlorobenzenów","parameters":[{"name":"chlorobenzen","range":"(0,010 - 25) mg/kg"},{"name":"1,2-dichlorobenzen","range":"(0,010 - 25) mg/kg"},{"name":"1,3-dichlorobenzen","range":"(0,010 - 25) mg/kg"},{"name":"1,4-dichlorobenzen","range":"(0,010 - 25) mg/kg"},{"name":"1,2,3-trichlorobenzen","range":"(0,010 - 25) mg/kg"},{"name":"1,2,4-trichlorobenzen","range":"(0,010 - 25) mg/kg"},{"name":"1,3,5-trichlorobenzen","range":"(0,010 - 25) mg/kg"},{"name":"1,2,3,4-tetrachlorobenzen","range":"(0,010 - 25) mg/kg"},{"name":"1,2,3,5-tetrachlorobenzen","range":"(0,010 - 25) mg/kg"},{"name":"1,2,4,5-tetrachlorobenzen","range":"(0,010 - 25) mg/kg"},{"name":"pentachlorobenzen","range":"(0,010 - 25) mg/kg"},{"name":"heksachlorobenzen (HCB)","range":"(0,010 - 25) mg/kg"},{"name":"Chlorobenzeny (suma) (z obliczeń)"},{"name":"Dichlorobenzeny (suma) (z obliczeń)"},{"name":"Trichlorobenzeny (suma) (z obliczeń)"},{"name":"Tetrachlorobenzeny (suma) (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość chlorobenzenów\nZakres:\nchlorobenzen (0,010 - 25) mg/kg\n1,2-dichlorobenzen (0,010 - 25) mg/kg\n1,3-dichlorobenzen (0,010 - 25) mg/kg\n1,4-dichlorobenzen (0,010 - 25) mg/kg\n1,2,3-trichlorobenzen (0,010 - 25) mg/kg\n1,2,4-trichlorobenzen (0,010 - 25) mg/kg\n1,3,5-trichlorobenzen (0,010 - 25) mg/kg\n1,2,3,4-tetrachlorobenzen (0,010 - 25) mg/kg\n1,2,3,5-tetrachlorobenzen (0,010 - 25) mg/kg\n1,2,4,5-tetrachlorobenzen (0,010 - 25) mg/kg\npentachlorobenzen (0,010 - 25) mg/kg\nheksachlorobenzen (HCB) (0,010 - 25) mg/kg\nChlorobenzeny (suma) (z obliczeń)\nDichlorobenzeny (suma) (z obliczeń)\nTrichlorobenzeny (suma) (z obliczeń)\nTetrachlorobenzeny (suma) (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PB-220/LF wyd. 4 z dnia 20.01.2022 M","norm_bases":["PB-220/LF wyd. 4 z dnia 20.01.2022 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość chlorobenzenów\nZakres:\nchlorobenzen (0,010 - 25) mg/kg\n1,2-dichlorobenzen (0,010 - 25) mg/kg\n1,3-dichlorobenzen (0,010 - 25) mg/kg\n1,4-dichlorobenzen (0,010 - 25) mg/kg\n1,2,3-trichlorobenzen (0,010 - 25) mg/kg\n1,2,4-trichlorobenzen (0,010 - 25) mg/kg\n1,3,5-trichlorobenzen (0,010 - 25) mg/kg\n1,2,3,4-tetrachlorobenzen (0,010 - 25) mg/kg\n1,2,3,5-tetrachlorobenzen (0,010 - 25) mg/kg\n1,2,4,5-tetrachlorobenzen (0,010 - 25) mg/kg\npentachlorobenzen (0,010 - 25) mg/kg\nheksachlorobenzen (HCB) (0,010 - 25) mg/kg\nChlorobenzeny (suma) (z obliczeń)\nDichlorobenzeny (suma) (z obliczeń)\nTrichlorobenzeny (suma) (z obliczeń)\nTetrachlorobenzeny (suma) (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PB-220/LF wyd. 4 z dnia 20.01.2022 M Gleba Zawartosc chlorobenzenow\nZakres:\nchlorobenzen (0,010 - 25) mg/kg\n1,2-dichlorobenzen (0,010 - 25) mg/kg\n1,3-dichlorobenzen (0,010 - 25) mg/kg\n1,4-dichlorobenzen (0,010 - 25) mg/kg\n1,2,3-trichlorobenzen (0,010 - 25) mg/kg\n1,2,4-trichlorobenzen (0,010 - 25) mg/kg\n1,3,5-trichlorobenzen (0,010 - 25) mg/kg\n1,2,3,4-tetrachlorobenzen (0,010 - 25) mg/kg\n1,2,3,5-tetrachlorobenzen (0,010 - 25) mg/kg\n1,2,4,5-tetrachlorobenzen (0,010 - 25) mg/kg\npentachlorobenzen (0,010 - 25) mg/kg\nheksachlorobenzen (HCB) (0,010 - 25) mg/kg\nChlorobenzeny (suma) (z obliczen)\nDichlorobenzeny (suma) (z obliczen)\nTrichlorobenzeny (suma) (z obliczen)\nTetrachlorobenzeny (suma) (z obliczen)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PB-220/LF wyd. 4 z dnia 20.01.2022 M","categories":["environment"],"row_index":199,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorobenzene content","parameters_en":[{"name":"chlorobenzene","range":"(0,010 - 25) mg/kg"},{"name":"1,2-dichlorobenzene","range":"(0,010 - 25) mg/kg"},{"name":"1,3-dichlorobenzene","range":"(0,010 - 25) mg/kg"},{"name":"1,4-dichlorobenzene","range":"(0,010 - 25) mg/kg"},{"name":"1,2,3-trichlorobenzene","range":"(0,010 - 25) mg/kg"},{"name":"1,2,4-trichlorobenzene","range":"(0,010 - 25) mg/kg"},{"name":"1,3,5-trichlorobenzene","range":"(0,010 - 25) mg/kg"},{"name":"1,2,3,4-tetrachlorobenzene","range":"(0,010 - 25) mg/kg"},{"name":"1,2,3,5-tetrachlorobenzene","range":"(0,010 - 25) mg/kg"},{"name":"1,2,4,5-tetrachlorobenzene","range":"(0,010 - 25) mg/kg"},{"name":"pentachlorobenzene","range":"(0,010 - 25) mg/kg"},{"name":"hexachlorobenzene (HCB)","range":"(0,010 - 25) mg/kg"},{"name":"Chlorobenzeny (suma) (z obliczeń)"},{"name":"Dichlorobenzeny (suma) (z obliczeń)"},{"name":"Trichlorobenzeny (suma) (z obliczeń)"},{"name":"Tetrachlorobenzeny (suma) (z obliczeń)"}],"search_en":"Soil Chlorobenzene content Gas chromatography with mass spectrometry detection (GC-MS) chlorobenzene 1,2-dichlorobenzene 1,3-dichlorobenzene 1,4-dichlorobenzene 1,2,3-trichlorobenzene 1,2,4-trichlorobenzene 1,3,5-trichlorobenzene 1,2,3,4-tetrachlorobenzene 1,2,3,5-tetrachlorobenzene 1,2,4,5-tetrachlorobenzene pentachlorobenzene hexachlorobenzene (HCB) PB-220/LF wyd. 4 z dnia 20.01.2022 M","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Soil","search_zh":"土壤 氯苯类含量 气相色谱-质谱法（GC-MS） 氯苯 1,2-二氯苯 1,3-二氯苯 1,4-二氯苯 1,2,3-三氯苯 1,2,4-三氯苯 1,3,5-三氯苯 1,2,3,4-四氯苯 五氯苯 六氯苯（HCB） PB-220/LF wyd. 4 z dnia 20.01.2022 M","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"土壤","parameters_zh":[{"name":"氯苯","range":"(0,010 - 25) mg/kg"},{"name":"1,2-二氯苯","range":"(0,010 - 25) mg/kg"},{"name":"1,3-二氯苯","range":"(0,010 - 25) mg/kg"},{"name":"1,4-二氯苯","range":"(0,010 - 25) mg/kg"},{"name":"1,2,3-三氯苯","range":"(0,010 - 25) mg/kg"},{"name":"1,2,4-三氯苯","range":"(0,010 - 25) mg/kg"},{"name":"1,3,5-三氯苯","range":"(0,010 - 25) mg/kg"},{"name":"1,2,3,4-四氯苯","range":"(0,010 - 25) mg/kg"},{"name":"1,2,3,5-tetrachlorobenzen","range":"(0,010 - 25) mg/kg"},{"name":"1,2,4,5-tetrachlorobenzen","range":"(0,010 - 25) mg/kg"},{"name":"五氯苯","range":"(0,010 - 25) mg/kg"},{"name":"六氯苯（HCB）","range":"(0,010 - 25) mg/kg"},{"name":"Chlorobenzeny (suma) (z obliczeń)"},{"name":"Dichlorobenzeny (suma) (z obliczeń)"},{"name":"Trichlorobenzeny (suma) (z obliczeń)"},{"name":"Tetrachlorobenzeny (suma) (z obliczeń)"}],"methodology_zh":"氯苯类含量"},{"_id":"6a82c6ff884ede9a1b2c2a14","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość chloronaftalenów","parameters":[{"name":"1-chloronaftalen","range":"(0,010 - 1,0) mg/kg"},{"name":"2-chloronaftalen","range":"(0,010 - 1,0) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość chloronaftalenów\nZakres:\n1-chloronaftalen (0,010 - 1,0) mg/kg\n2-chloronaftalen (0,010 - 1,0) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PB-221/LF wyd. 4 z dnia 20.01.2022 M","norm_bases":["PB-221/LF wyd. 4 z dnia 20.01.2022 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość chloronaftalenów\nZakres:\n1-chloronaftalen (0,010 - 1,0) mg/kg\n2-chloronaftalen (0,010 - 1,0) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PB-221/LF wyd. 4 z dnia 20.01.2022 M Gleba Zawartosc chloronaftalenow\nZakres:\n1-chloronaftalen (0,010 - 1,0) mg/kg\n2-chloronaftalen (0,010 - 1,0) mg/kg\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PB-221/LF wyd. 4 z dnia 20.01.2022 M","categories":["environment"],"row_index":200,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloronaphthalene content","parameters_en":[{"name":"1-chloronaphthalene","range":"(0,010 - 1,0) mg/kg"},{"name":"2-chloronaphthalene","range":"(0,010 - 1,0) mg/kg"}],"search_en":"Soil Chloronaphthalene content Gas chromatography with mass spectrometry detection (GC-MS) 1-chloronaphthalene 2-chloronaphthalene PB-221/LF wyd. 4 z dnia 20.01.2022 M","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Soil","search_zh":"土壤 氯代萘含量 气相色谱-质谱法（GC-MS） PB-221/LF wyd. 4 z dnia 20.01.2022 M","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"土壤","methodology_zh":"氯代萘含量"},{"_id":"6a82c6ff884ede9a1b2c2a15","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość krezoli","parameters":[{"name":"2-metylofenol (o-krezol)","range":"(0,050 - 20) mg/kg"},{"name":"3-metylofenol (m-krezol)","range":"(0,050 - 20) mg/kg"},{"name":"4-metylofenol (p-krezol)","range":"(0,050 - 20) mg/kg"},{"name":"Suma krezoli (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość krezoli\nZakres:\n2-metylofenol (o-krezol) (0,050 - 20) mg/kg\n3-metylofenol (m-krezol) (0,050 - 20) mg/kg\n4-metylofenol (p-krezol) (0,050 - 20) mg/kg\nSuma krezoli (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PB-218/LF wyd. 6 z dnia 20.01.2022 M","norm_bases":["PB-218/LF wyd. 6 z dnia 20.01.2022 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość krezoli\nZakres:\n2-metylofenol (o-krezol) (0,050 - 20) mg/kg\n3-metylofenol (m-krezol) (0,050 - 20) mg/kg\n4-metylofenol (p-krezol) (0,050 - 20) mg/kg\nSuma krezoli (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PB-218/LF wyd. 6 z dnia 20.01.2022 M Gleba Zawartosc krezoli\nZakres:\n2-metylofenol (o-krezol) (0,050 - 20) mg/kg\n3-metylofenol (m-krezol) (0,050 - 20) mg/kg\n4-metylofenol (p-krezol) (0,050 - 20) mg/kg\nSuma krezoli (z obliczen)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PB-218/LF wyd. 6 z dnia 20.01.2022 M","categories":["environment"],"row_index":201,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cresol content","parameters_en":[{"name":"2-methylphenol (o-cresol)","range":"(0,050 - 20) mg/kg"},{"name":"3-methylphenol (m-cresol)","range":"(0,050 - 20) mg/kg"},{"name":"4-methylphenol (p-cresol)","range":"(0,050 - 20) mg/kg"},{"name":"Sum of cresols (calculated)"}],"search_en":"Soil Cresol content Gas chromatography with mass spectrometry detection (GC-MS) 2-methylphenol (o-cresol) 3-methylphenol (m-cresol) 4-methylphenol (p-cresol) Sum of cresols (calculated) PB-218/LF wyd. 6 z dnia 20.01.2022 M","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Soil","search_zh":"土壤 甲酚含量 气相色谱-质谱法（GC-MS） 2-甲基苯酚（邻甲酚） 3-甲基苯酚（间甲酚） 4-甲基苯酚（对甲酚） 甲酚总量（由计算得出） PB-218/LF wyd. 6 z dnia 20.01.2022 M","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"土壤","parameters_zh":[{"name":"2-甲基苯酚（邻甲酚）","range":"(0,050 - 20) mg/kg"},{"name":"3-甲基苯酚（间甲酚）","range":"(0,050 - 20) mg/kg"},{"name":"4-甲基苯酚（对甲酚）","range":"(0,050 - 20) mg/kg"},{"name":"甲酚总量（由计算得出）"}],"methodology_zh":"甲酚含量"},{"_id":"6a82c6ff884ede9a1b2c2a16","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość fenolu","parameters":[{"name":"Zakres","range":"(0,050 - 100) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość fenolu\nZakres (0,050 - 100) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PB-218/LF wyd. 6 z dnia 20.01.2022 M","norm_bases":["PB-218/LF wyd. 6 z dnia 20.01.2022 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość fenolu\nZakres (0,050 - 100) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PB-218/LF wyd. 6 z dnia 20.01.2022 M Gleba Zawartosc fenolu\nZakres (0,050 - 100) mg/kg\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PB-218/LF wyd. 6 z dnia 20.01.2022 M","categories":["environment"],"row_index":202,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol content","parameters_en":[{"name":"Range","range":"(0,050 - 100) mg/kg"}],"search_en":"Soil Phenol content Gas chromatography with mass spectrometry detection (GC-MS) Range PB-218/LF wyd. 6 z dnia 20.01.2022 M","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(0,050 - 100) mg/kg"}],"search_zh":"土壤 苯酚含量 气相色谱-质谱法（GC-MS） 范围 PB-218/LF wyd. 6 z dnia 20.01.2022 M","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"土壤","methodology_zh":"苯酚含量"},{"_id":"6a82c6ff884ede9a1b2c2a17","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość cykloheksanu","parameters":[{"name":"Zakres","range":"(0,10 - 100) mg/kg"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)"],"computed":[],"activity":"Zawartość cykloheksanu\nZakres (0,10 - 100) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","reference":"PN-EN ISO 22155:2016-07 M","norm_bases":["PN-EN ISO 22155:2016-07 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość cykloheksanu\nZakres (0,10 - 100) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) PN-EN ISO 22155:2016-07 M Gleba Zawartosc cykloheksanu\nZakres (0,10 - 100) mg/kg\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) PN-EN ISO 22155:2016-07 M","categories":["environment"],"row_index":203,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cyclohexane content","parameters_en":[{"name":"Range","range":"(0,10 - 100) mg/kg"}],"search_en":"Soil Cyclohexane content Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) Range PN-EN ISO 22155:2016-07 M","technique_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(0,10 - 100) mg/kg"}],"search_zh":"土壤 环己烷含量 顶空气相色谱-质谱法（HS-GC-MS） 范围 PN-EN ISO 22155:2016-07 M","test_object_zh":"土壤","technique_zh":"顶空气相色谱-质谱法（HS-GC-MS）","methodology_zh":"环己烷含量"},{"_id":"6a82c6ff884ede9a1b2c2a18","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość chlorofenoli","parameters":[{"name":"2-chlorofenol","range":"(0,010 – 1,0) mg/kg"},{"name":"3-chlorofenol","range":"(0,010 – 1,0) mg/kg"},{"name":"4-chlorofenol","range":"(0,010 – 1,0) mg/kg"},{"name":"2,3-dichlorofenol","range":"(0,010 – 1,0) mg/kg"},{"name":"2,4-dichlorofenol","range":"(0,010 – 1,0) mg/kg"},{"name":"2,5-dichlorofenol","range":"(0,010 – 1,0) mg/kg"},{"name":"2,6-dichlorofenol","range":"(0,010 – 1,0) mg/kg"},{"name":"3,4-dichlorofenol","range":"(0,010 – 1,0) mg/kg"},{"name":"3,5-dichlorofenol","range":"(0,010 – 1,0) mg/kg"},{"name":"2,3,4-trichlorofenol","range":"(0,010 – 1,0) mg/kg"},{"name":"2,3,5-trichlorofenol","range":"(0,010 – 1,0) mg/kg"},{"name":"2,3,6-trichlorofenol","range":"(0,010 – 1,0) mg/kg"},{"name":"2,4,5-trichlorofenol","range":"(0,010 – 1,0) mg/kg"},{"name":"2,4,6-trichlorofenol","range":"(0,010 – 1,0) mg/kg"},{"name":"3,4,5-trichlorofenol","range":"(0,010 – 1,0) mg/kg"},{"name":"2,3,4,5-tetrachlorofenol","range":"(0,010 – 1,0) mg/kg"},{"name":"2,3,4,6-tetrachlorofenol","range":"(0,010 – 1,0) mg/kg"},{"name":"2,3,5,6-tetrachlorofenol","range":"(0,010 – 1,0) mg/kg"},{"name":"pentachlorofenol (PCP)","range":"(0,010 – 1,0) mg/kg"},{"name":"Chlorofenole (suma) (z obliczeń)"},{"name":"Monochlorofenole (suma) (z obliczeń)"},{"name":"Dichlorofenole (suma) (z obliczeń)"},{"name":"Trichlorofenole (suma) (z obliczeń)"},{"name":"Tetrachlorofenole (suma) (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość chlorofenoli\nZakres:\n2-chlorofenol (0,010 – 1,0) mg/kg\n3-chlorofenol (0,010 – 1,0) mg/kg\n4-chlorofenol (0,010 – 1,0) mg/kg\n2,3-dichlorofenol (0,010 – 1,0) mg/kg\n2,4-dichlorofenol (0,010 – 1,0) mg/kg\n2,5-dichlorofenol (0,010 – 1,0) mg/kg\n2,6-dichlorofenol (0,010 – 1,0) mg/kg\n3,4-dichlorofenol (0,010 – 1,0) mg/kg\n3,5-dichlorofenol (0,010 – 1,0) mg/kg\n2,3,4-trichlorofenol (0,010 – 1,0) mg/kg\n2,3,5-trichlorofenol (0,010 – 1,0) mg/kg\n2,3,6-trichlorofenol (0,010 – 1,0) mg/kg\n2,4,5-trichlorofenol (0,010 – 1,0) mg/kg\n2,4,6-trichlorofenol (0,010 – 1,0) mg/kg\n3,4,5-trichlorofenol (0,010 – 1,0) mg/kg\n2,3,4,5-tetrachlorofenol (0,010 – 1,0) mg/kg\n2,3,4,6-tetrachlorofenol (0,010 – 1,0) mg/kg\n2,3,5,6-tetrachlorofenol (0,010 – 1,0) mg/kg\npentachlorofenol (PCP) (0,010 – 1,0) mg/kg\nChlorofenole (suma) (z obliczeń)\nMonochlorofenole (suma) (z obliczeń)\nDichlorofenole (suma) (z obliczeń)\nTrichlorofenole (suma) (z obliczeń)\nTetrachlorofenole (suma) (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PN-ISO 14154:2008 M","norm_bases":["PN-ISO 14154:2008 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość chlorofenoli\nZakres:\n2-chlorofenol (0,010 – 1,0) mg/kg\n3-chlorofenol (0,010 – 1,0) mg/kg\n4-chlorofenol (0,010 – 1,0) mg/kg\n2,3-dichlorofenol (0,010 – 1,0) mg/kg\n2,4-dichlorofenol (0,010 – 1,0) mg/kg\n2,5-dichlorofenol (0,010 – 1,0) mg/kg\n2,6-dichlorofenol (0,010 – 1,0) mg/kg\n3,4-dichlorofenol (0,010 – 1,0) mg/kg\n3,5-dichlorofenol (0,010 – 1,0) mg/kg\n2,3,4-trichlorofenol (0,010 – 1,0) mg/kg\n2,3,5-trichlorofenol (0,010 – 1,0) mg/kg\n2,3,6-trichlorofenol (0,010 – 1,0) mg/kg\n2,4,5-trichlorofenol (0,010 – 1,0) mg/kg\n2,4,6-trichlorofenol (0,010 – 1,0) mg/kg\n3,4,5-trichlorofenol (0,010 – 1,0) mg/kg\n2,3,4,5-tetrachlorofenol (0,010 – 1,0) mg/kg\n2,3,4,6-tetrachlorofenol (0,010 – 1,0) mg/kg\n2,3,5,6-tetrachlorofenol (0,010 – 1,0) mg/kg\npentachlorofenol (PCP) (0,010 – 1,0) mg/kg\nChlorofenole (suma) (z obliczeń)\nMonochlorofenole (suma) (z obliczeń)\nDichlorofenole (suma) (z obliczeń)\nTrichlorofenole (suma) (z obliczeń)\nTetrachlorofenole (suma) (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PN-ISO 14154:2008 M Gleba Zawartosc chlorofenoli\nZakres:\n2-chlorofenol (0,010 – 1,0) mg/kg\n3-chlorofenol (0,010 – 1,0) mg/kg\n4-chlorofenol (0,010 – 1,0) mg/kg\n2,3-dichlorofenol (0,010 – 1,0) mg/kg\n2,4-dichlorofenol (0,010 – 1,0) mg/kg\n2,5-dichlorofenol (0,010 – 1,0) mg/kg\n2,6-dichlorofenol (0,010 – 1,0) mg/kg\n3,4-dichlorofenol (0,010 – 1,0) mg/kg\n3,5-dichlorofenol (0,010 – 1,0) mg/kg\n2,3,4-trichlorofenol (0,010 – 1,0) mg/kg\n2,3,5-trichlorofenol (0,010 – 1,0) mg/kg\n2,3,6-trichlorofenol (0,010 – 1,0) mg/kg\n2,4,5-trichlorofenol (0,010 – 1,0) mg/kg\n2,4,6-trichlorofenol (0,010 – 1,0) mg/kg\n3,4,5-trichlorofenol (0,010 – 1,0) mg/kg\n2,3,4,5-tetrachlorofenol (0,010 – 1,0) mg/kg\n2,3,4,6-tetrachlorofenol (0,010 – 1,0) mg/kg\n2,3,5,6-tetrachlorofenol (0,010 – 1,0) mg/kg\npentachlorofenol (PCP) (0,010 – 1,0) mg/kg\nChlorofenole (suma) (z obliczen)\nMonochlorofenole (suma) (z obliczen)\nDichlorofenole (suma) (z obliczen)\nTrichlorofenole (suma) (z obliczen)\nTetrachlorofenole (suma) (z obliczen)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PN-ISO 14154:2008 M","categories":["environment"],"row_index":204,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorophenol content","parameters_en":[{"name":"2-chlorophenol","range":"(0,010 – 1,0) mg/kg"},{"name":"3-chlorophenol","range":"(0,010 – 1,0) mg/kg"},{"name":"4-chlorophenol","range":"(0,010 – 1,0) mg/kg"},{"name":"2,3-dichlorophenol","range":"(0,010 – 1,0) mg/kg"},{"name":"2,4-dichlorophenol","range":"(0,010 – 1,0) mg/kg"},{"name":"2,5-dichlorophenol","range":"(0,010 – 1,0) mg/kg"},{"name":"2,6-dichlorophenol","range":"(0,010 – 1,0) mg/kg"},{"name":"3,4-dichlorophenol","range":"(0,010 – 1,0) mg/kg"},{"name":"3,5-dichlorophenol","range":"(0,010 – 1,0) mg/kg"},{"name":"2,3,4-trichlorophenol","range":"(0,010 – 1,0) mg/kg"},{"name":"2,3,5-trichlorophenol","range":"(0,010 – 1,0) mg/kg"},{"name":"2,3,6-trichlorophenol","range":"(0,010 – 1,0) mg/kg"},{"name":"2,4,5-trichlorophenol","range":"(0,010 – 1,0) mg/kg"},{"name":"2,4,6-trichlorophenol","range":"(0,010 – 1,0) mg/kg"},{"name":"3,4,5-trichlorophenol","range":"(0,010 – 1,0) mg/kg"},{"name":"2,3,4,5-tetrachlorophenol","range":"(0,010 – 1,0) mg/kg"},{"name":"2,3,4,6-tetrachlorophenol","range":"(0,010 – 1,0) mg/kg"},{"name":"2,3,5,6-tetrachlorophenol","range":"(0,010 – 1,0) mg/kg"},{"name":"pentachlorophenol (PCP)","range":"(0,010 – 1,0) mg/kg"},{"name":"Chlorofenole (suma) (z obliczeń)"},{"name":"Monochlorofenole (suma) (z obliczeń)"},{"name":"Dichlorofenole (suma) (z obliczeń)"},{"name":"Trichlorofenole (suma) (z obliczeń)"},{"name":"Tetrachlorofenole (suma) (z obliczeń)"}],"search_en":"Soil Chlorophenol content Gas chromatography with mass spectrometry detection (GC-MS) 2-chlorophenol 3-chlorophenol 4-chlorophenol 2,3-dichlorophenol 2,4-dichlorophenol 2,5-dichlorophenol 2,6-dichlorophenol 3,4-dichlorophenol 3,5-dichlorophenol 2,3,4-trichlorophenol 2,3,5-trichlorophenol 2,3,6-trichlorophenol 2,4,5-trichlorophenol 2,4,6-trichlorophenol 3,4,5-trichlorophenol 2,3,4,5-tetrachlorophenol 2,3,4,6-tetrachlorophenol 2,3,5,6-tetrachlorophenol pentachlorophenol (PCP) PN-ISO 14154:2008 M","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Soil","search_zh":"土壤 氯酚含量 气相色谱-质谱法（GC-MS） 3-氯苯酚 4-氯苯酚 2,3-二氯苯酚 2,6-二氯苯酚 3,4-二氯苯酚 3,5-二氯苯酚 2,3,4-三氯苯酚 2,3,5-三氯苯酚 2,3,6-三氯苯酚 2,4,5-三氯苯酚 2,4,6-三氯苯酚 3,4,5-三氯苯酚 2,3,4,5-四氯苯酚 2,3,4,6-四氯苯酚 五氯苯酚（PCP） PN-ISO 14154:2008 M","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"土壤","methodology_zh":"氯酚含量","parameters_zh":[{"name":"2-chlorofenol","range":"(0,010 – 1,0) mg/kg"},{"name":"3-氯苯酚","range":"(0,010 – 1,0) mg/kg"},{"name":"4-氯苯酚","range":"(0,010 – 1,0) mg/kg"},{"name":"2,3-二氯苯酚","range":"(0,010 – 1,0) mg/kg"},{"name":"2,4-dichlorofenol","range":"(0,010 – 1,0) mg/kg"},{"name":"2,5-dichlorofenol","range":"(0,010 – 1,0) mg/kg"},{"name":"2,6-二氯苯酚","range":"(0,010 – 1,0) mg/kg"},{"name":"3,4-二氯苯酚","range":"(0,010 – 1,0) mg/kg"},{"name":"3,5-二氯苯酚","range":"(0,010 – 1,0) mg/kg"},{"name":"2,3,4-三氯苯酚","range":"(0,010 – 1,0) mg/kg"},{"name":"2,3,5-三氯苯酚","range":"(0,010 – 1,0) mg/kg"},{"name":"2,3,6-三氯苯酚","range":"(0,010 – 1,0) mg/kg"},{"name":"2,4,5-三氯苯酚","range":"(0,010 – 1,0) mg/kg"},{"name":"2,4,6-三氯苯酚","range":"(0,010 – 1,0) mg/kg"},{"name":"3,4,5-三氯苯酚","range":"(0,010 – 1,0) mg/kg"},{"name":"2,3,4,5-四氯苯酚","range":"(0,010 – 1,0) mg/kg"},{"name":"2,3,4,6-四氯苯酚","range":"(0,010 – 1,0) mg/kg"},{"name":"2,3,5,6-tetrachlorofenol","range":"(0,010 – 1,0) mg/kg"},{"name":"五氯苯酚（PCP）","range":"(0,010 – 1,0) mg/kg"},{"name":"Chlorofenole (suma) (z obliczeń)"},{"name":"Monochlorofenole (suma) (z obliczeń)"},{"name":"Dichlorofenole (suma) (z obliczeń)"},{"name":"Trichlorofenole (suma) (z obliczeń)"},{"name":"Tetrachlorofenole (suma) (z obliczeń)"}]},{"_id":"6a82c6ff884ede9a1b2c2a19","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość ftalanów","parameters":[{"name":"ftalan dimetylu","range":"(0,10 - 60) mg/kg"},{"name":"ftalan dietylu","range":"(0,10 - 60) mg/kg"},{"name":"ftalan di-n-butylu","range":"(0,10 - 60) mg/kg"},{"name":"ftalan di-n-oktylu","range":"(0,10 - 60) mg/kg"},{"name":"ftalan bis","range":"(2-etyloheksylu) DEHP"},{"name":"Zakres","range":"(0,10 - 60) mg/kg"},{"name":"ftalan benzylobutylu","range":"(0,10 - 60) mg/kg"},{"name":"ftalan di-izo-butylu","range":"(0,10 - 60) mg/kg"},{"name":"Suma ftalanów (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość ftalanów\nZakres:\nftalan dimetylu (0,10 - 60) mg/kg\nftalan dietylu (0,10 - 60) mg/kg\nftalan di-n-butylu (0,10 - 60) mg/kg\nftalan di-n-oktylu (0,10 - 60) mg/kg\nftalan bis (2-etyloheksylu) DEHP\nZakres (0,10 - 60) mg/kg\nftalan benzylobutylu (0,10 - 60) mg/kg\nftalan di-izo-butylu (0,10 - 60) mg/kg\nSuma ftalanów (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PB-222/LF wyd. 5 z dnia 20.01.2022 M","norm_bases":["PB-222/LF wyd. 5 z dnia 20.01.2022 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość ftalanów\nZakres:\nftalan dimetylu (0,10 - 60) mg/kg\nftalan dietylu (0,10 - 60) mg/kg\nftalan di-n-butylu (0,10 - 60) mg/kg\nftalan di-n-oktylu (0,10 - 60) mg/kg\nftalan bis (2-etyloheksylu) DEHP\nZakres (0,10 - 60) mg/kg\nftalan benzylobutylu (0,10 - 60) mg/kg\nftalan di-izo-butylu (0,10 - 60) mg/kg\nSuma ftalanów (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PB-222/LF wyd. 5 z dnia 20.01.2022 M Gleba Zawartosc ftalanow\nZakres:\nftalan dimetylu (0,10 - 60) mg/kg\nftalan dietylu (0,10 - 60) mg/kg\nftalan di-n-butylu (0,10 - 60) mg/kg\nftalan di-n-oktylu (0,10 - 60) mg/kg\nftalan bis (2-etyloheksylu) DEHP\nZakres (0,10 - 60) mg/kg\nftalan benzylobutylu (0,10 - 60) mg/kg\nftalan di-izo-butylu (0,10 - 60) mg/kg\nSuma ftalanow (z obliczen)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PB-222/LF wyd. 5 z dnia 20.01.2022 M","categories":["environment"],"row_index":205,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phthalate content","parameters_en":[{"name":"dimethyl phthalate","range":"(0,10 - 60) mg/kg"},{"name":"diethyl phthalate","range":"(0,10 - 60) mg/kg"},{"name":"di-n-butyl phthalate","range":"(0,10 - 60) mg/kg"},{"name":"di-n-octyl phthalate","range":"(0,10 - 60) mg/kg"},{"name":"bis phthalate","range":"(2-etyloheksylu) DEHP"},{"name":"Range","range":"(0,10 - 60) mg/kg"},{"name":"benzyl butyl phthalate","range":"(0,10 - 60) mg/kg"},{"name":"di-iso-butyl phthalate","range":"(0,10 - 60) mg/kg"},{"name":"Sum of phthalates (calculated)"}],"search_en":"Soil Phthalate content Gas chromatography with mass spectrometry detection (GC-MS) dimethyl phthalate diethyl phthalate di-n-butyl phthalate di-n-octyl phthalate bis phthalate Range benzyl butyl phthalate di-iso-butyl phthalate Sum of phthalates (calculated) PB-222/LF wyd. 5 z dnia 20.01.2022 M","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Soil","parameters_zh":[{"name":"邻苯二甲酸二甲酯","range":"(0,10 - 60) mg/kg"},{"name":"邻苯二甲酸二乙酯","range":"(0,10 - 60) mg/kg"},{"name":"ftalan di-n-butylu","range":"(0,10 - 60) mg/kg"},{"name":"邻苯二甲酸二正辛酯","range":"(0,10 - 60) mg/kg"},{"name":"邻苯二甲酸二酯","range":"(2-etyloheksylu) DEHP"},{"name":"范围","range":"(0,10 - 60) mg/kg"},{"name":"ftalan benzylobutylu","range":"(0,10 - 60) mg/kg"},{"name":"ftalan di-izo-butylu","range":"(0,10 - 60) mg/kg"},{"name":"邻苯二甲酸酯总量（由计算得出）"}],"search_zh":"土壤 邻苯二甲酸酯含量 气相色谱-质谱法（GC-MS） 邻苯二甲酸二甲酯 邻苯二甲酸二乙酯 邻苯二甲酸二正辛酯 邻苯二甲酸二酯 范围 邻苯二甲酸酯总量（由计算得出） PB-222/LF wyd. 5 z dnia 20.01.2022 M","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"土壤","methodology_zh":"邻苯二甲酸酯含量"},{"_id":"6a82c6ff884ede9a1b2c2a1a","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość pestycydów","parameters":[{"name":"karbaryl","range":"(0,050 – 10) mg/kg"},{"name":"karbofuran","range":"(0,050 – 10) mg/kg"},{"name":"atrazyna","range":"(0,0050 – 10) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość pestycydów\nZakres:\nkarbaryl (0,050 – 10) mg/kg\nkarbofuran (0,050 – 10) mg/kg\natrazyna (0,0050 – 10) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PB-39/LF wyd. 3 z dnia 20.01.2022 M","norm_bases":["PB-39/LF wyd. 3 z dnia 20.01.2022 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość pestycydów\nZakres:\nkarbaryl (0,050 – 10) mg/kg\nkarbofuran (0,050 – 10) mg/kg\natrazyna (0,0050 – 10) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PB-39/LF wyd. 3 z dnia 20.01.2022 M Gleba Zawartosc pestycydow\nZakres:\nkarbaryl (0,050 – 10) mg/kg\nkarbofuran (0,050 – 10) mg/kg\natrazyna (0,0050 – 10) mg/kg\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PB-39/LF wyd. 3 z dnia 20.01.2022 M","categories":["environment"],"row_index":206,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pesticide content","parameters_en":[{"name":"carbaryl","range":"(0,050 – 10) mg/kg"},{"name":"carbofuran","range":"(0,050 – 10) mg/kg"},{"name":"atrazine","range":"(0,0050 – 10) mg/kg"}],"search_en":"Soil Pesticide content Gas chromatography with mass spectrometry detection (GC-MS) carbaryl carbofuran atrazine PB-39/LF wyd. 3 z dnia 20.01.2022 M","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Soil","search_zh":"土壤 农药含量 气相色谱-质谱法（GC-MS） 莠去津 PB-39/LF wyd. 3 z dnia 20.01.2022 M","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"土壤","methodology_zh":"农药含量","parameters_zh":[{"name":"karbaryl","range":"(0,050 – 10) mg/kg"},{"name":"karbofuran","range":"(0,050 – 10) mg/kg"},{"name":"莠去津","range":"(0,0050 – 10) mg/kg"}]},{"_id":"6a82c6ff884ede9a1b2c2a1b","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość tetrahydrotiofenu","parameters":[{"name":"Zakres","range":"(0,10 - 1,5) mg/kg"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)"],"computed":[],"activity":"Zawartość tetrahydrotiofenu\nZakres (0,10 - 1,5) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","reference":"PB-40/LF wyd. 3 z dnia 20.01.2022 M","norm_bases":["PB-40/LF wyd. 3 z dnia 20.01.2022 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość tetrahydrotiofenu\nZakres (0,10 - 1,5) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) PB-40/LF wyd. 3 z dnia 20.01.2022 M Gleba Zawartosc tetrahydrotiofenu\nZakres (0,10 - 1,5) mg/kg\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) PB-40/LF wyd. 3 z dnia 20.01.2022 M","categories":["environment"],"row_index":207,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Tetrahydrothiophene content","parameters_en":[{"name":"Range","range":"(0,10 - 1,5) mg/kg"}],"search_en":"Soil Tetrahydrothiophene content Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) Range PB-40/LF wyd. 3 z dnia 20.01.2022 M","technique_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(0,10 - 1,5) mg/kg"}],"search_zh":"土壤 顶空气相色谱-质谱法（HS-GC-MS） 范围 PB-40/LF wyd. 3 z dnia 20.01.2022 M","test_object_zh":"土壤","technique_zh":"顶空气相色谱-质谱法（HS-GC-MS）"},{"_id":"6a82c6ff884ede9a1b2c2a1c","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość pirydyny","parameters":[{"name":"Zakres","range":"(0,10 - 1,5) mg/kg"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)"],"computed":[],"activity":"Zawartość pirydyny\nZakres (0,10 - 1,5) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","reference":"PB-40/LF wyd. 3 z dnia 20.01.2022 M","norm_bases":["PB-40/LF wyd. 3 z dnia 20.01.2022 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość pirydyny\nZakres (0,10 - 1,5) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) PB-40/LF wyd. 3 z dnia 20.01.2022 M Gleba Zawartosc pirydyny\nZakres (0,10 - 1,5) mg/kg\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) PB-40/LF wyd. 3 z dnia 20.01.2022 M","categories":["environment"],"row_index":208,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pyridine content","parameters_en":[{"name":"Range","range":"(0,10 - 1,5) mg/kg"}],"search_en":"Soil Pyridine content Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) Range PB-40/LF wyd. 3 z dnia 20.01.2022 M","technique_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(0,10 - 1,5) mg/kg"}],"search_zh":"土壤 顶空气相色谱-质谱法（HS-GC-MS） 范围 PB-40/LF wyd. 3 z dnia 20.01.2022 M","test_object_zh":"土壤","technique_zh":"顶空气相色谱-质谱法（HS-GC-MS）"},{"_id":"6a82c6ff884ede9a1b2c2a1d","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość tetrahydrofuranu","parameters":[{"name":"Zakres","range":"(0,10 - 1,5) mg/kg"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)"],"computed":[],"activity":"Zawartość tetrahydrofuranu\nZakres (0,10 - 1,5) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","reference":"PB-40/LF wyd. 3 z dnia 20.01.2022 M","norm_bases":["PB-40/LF wyd. 3 z dnia 20.01.2022 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość tetrahydrofuranu\nZakres (0,10 - 1,5) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) PB-40/LF wyd. 3 z dnia 20.01.2022 M Gleba Zawartosc tetrahydrofuranu\nZakres (0,10 - 1,5) mg/kg\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) PB-40/LF wyd. 3 z dnia 20.01.2022 M","categories":["environment"],"row_index":209,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Tetrahydrofuran content","parameters_en":[{"name":"Range","range":"(0,10 - 1,5) mg/kg"}],"search_en":"Soil Tetrahydrofuran content Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) Range PB-40/LF wyd. 3 z dnia 20.01.2022 M","technique_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(0,10 - 1,5) mg/kg"}],"search_zh":"土壤 顶空气相色谱-质谱法（HS-GC-MS） 范围 PB-40/LF wyd. 3 z dnia 20.01.2022 M","test_object_zh":"土壤","technique_zh":"顶空气相色谱-质谱法（HS-GC-MS）"},{"_id":"6a82c6ff884ede9a1b2c2a1e","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba","methodology":"Całkowita zawartość węgla (TC)","parameters":[{"name":"Zakres","range":"(0,50 – 40) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Całkowita zawartość węgla (TC)\nZakres (0,50 – 40) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-ISO 10694:2002 M","norm_bases":["PN-ISO 10694:2002 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Całkowita zawartość węgla (TC)\nZakres (0,50 – 40) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-ISO 10694:2002 M Gleba Calkowita zawartosc wegla (TC)\nZakres (0,50 – 40) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-ISO 10694:2002 M","categories":["environment"],"row_index":210,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content (TC)","parameters_en":[{"name":"Range","range":"(0,50 – 40) %"}],"search_en":"Soil Total carbon content (TC) High-temperature combustion with IR detection Range PN-ISO 10694:2002 M","technique_en":"High-temperature combustion with IR detection","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(0,50 – 40) %"}],"search_zh":"土壤 高温燃烧红外检测法 范围 PN-ISO 10694:2002 M","technique_zh":"高温燃烧红外检测法","test_object_zh":"土壤"},{"_id":"6a82c6ff884ede9a1b2c2a1f","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość węgla nieorganicznego (TIC)","parameters":[{"name":"Zakres","range":"(0,50 - 15) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla nieorganicznego (TIC)\nZakres (0,50 - 15) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-ISO 10694:2002 M","norm_bases":["PN-ISO 10694:2002 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość węgla nieorganicznego (TIC)\nZakres (0,50 - 15) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-ISO 10694:2002 M Gleba Zawartosc wegla nieorganicznego (TIC)\nZakres (0,50 - 15) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-ISO 10694:2002 M","categories":["environment"],"row_index":211,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Inorganic carbon content (TIC)","parameters_en":[{"name":"Range","range":"(0,50 - 15) %"}],"search_en":"Soil Inorganic carbon content (TIC) High-temperature combustion with IR detection Range PN-ISO 10694:2002 M","technique_en":"High-temperature combustion with IR detection","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(0,50 - 15) %"}],"search_zh":"土壤 高温燃烧红外检测法 范围 PN-ISO 10694:2002 M","technique_zh":"高温燃烧红外检测法","test_object_zh":"土壤"},{"_id":"6a82c6ff884ede9a1b2c2a20","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość węgla organicznego (TOC) (z obliczeń), Zawartość substancji organicznej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość węgla organicznego (TOC) (z obliczeń), Zawartość substancji organicznej (z obliczeń)","reference":"PN-ISO 10694:2002 M","norm_bases":["PN-ISO 10694:2002 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość węgla organicznego (TOC) (z obliczeń), Zawartość substancji organicznej (z obliczeń) PN-ISO 10694:2002 M Gleba Zawartosc wegla organicznego (TOC) (z obliczen), Zawartosc substancji organicznej (z obliczen) PN-ISO 10694:2002 M","categories":["environment"],"row_index":212,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Organic carbon content (TOC) (calculated), Content of organic matter (calculated)","search_en":"Soil Organic carbon content (TOC) (calculated), Content of organic matter (calculated) PN-ISO 10694:2002 M","test_object_en":"Soil","search_zh":"土壤 PN-ISO 10694:2002 M","test_object_zh":"土壤"},{"_id":"6a82c6ff884ede9a1b2c2a21","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba","methodology":"Skład granulometryczny w zakresie wielkości cząstek (0,063 – 20) mm z podziałem na frakcje","parameters":[{"name":"Zakres","range":"(0,2 – 65,0) %"}],"technique":"Metoda sitowo-wagowa","techniques":["Metoda sitowo-wagowa"],"computed":[],"activity":"Skład granulometryczny w zakresie wielkości cząstek (0,063 – 20) mm z podziałem na frakcje\nZakres (0,2 – 65,0) %\nMetoda sitowo-wagowa","reference":"PB-295/LF wyd. 2 z dnia 24.01.2022 M","norm_bases":["PB-295/LF wyd. 2 z dnia 24.01.2022 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Skład granulometryczny w zakresie wielkości cząstek (0,063 – 20) mm z podziałem na frakcje\nZakres (0,2 – 65,0) %\nMetoda sitowo-wagowa PB-295/LF wyd. 2 z dnia 24.01.2022 M Gleba Sklad granulometryczny w zakresie wielkosci czastek (0,063 – 20) mm z podzialem na frakcje\nZakres (0,2 – 65,0) %\nMetoda sitowo-wagowa PB-295/LF wyd. 2 z dnia 24.01.2022 M","categories":["environment"],"row_index":213,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Particle size distribution in the particle size range (0,063 – 20) mm divided into fractions","parameters_en":[{"name":"Range","range":"(0,2 – 65,0) %"}],"search_en":"Soil Particle size distribution in the particle size range (0,063 – 20) mm divided into fractions Sieve-gravimetric method Range PB-295/LF wyd. 2 z dnia 24.01.2022 M","technique_en":"Sieve-gravimetric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(0,2 – 65,0) %"}],"search_zh":"土壤 筛析-重量法 范围 PB-295/LF wyd. 2 z dnia 24.01.2022 M","test_object_zh":"土壤","technique_zh":"筛析-重量法"},{"_id":"6a82c6ff884ede9a1b2c2a22","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Grunty, gleba","methodology":"Skład granulometryczny w zakresie wielkości cząstek (2 – 2000) μm","parameters":[{"name":"Zakres","range":"(1 – 99)%"}],"technique":"Metoda dyfrakcji laserowej","techniques":["Metoda dyfrakcji laserowej"],"computed":[],"activity":"Skład granulometryczny w zakresie wielkości cząstek (2 – 2000) μm\nZakres (1 – 99)%\nMetoda dyfrakcji laserowej","reference":"PB-264/LF wyd. 2 z dnia 24.01.2022 M","norm_bases":["PB-264/LF wyd. 2 z dnia 24.01.2022 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty, gleba Skład granulometryczny w zakresie wielkości cząstek (2 – 2000) μm\nZakres (1 – 99)%\nMetoda dyfrakcji laserowej PB-264/LF wyd. 2 z dnia 24.01.2022 M Grunty, gleba Sklad granulometryczny w zakresie wielkosci czastek (2 – 2000) μm\nZakres (1 – 99)%\nMetoda dyfrakcji laserowej PB-264/LF wyd. 2 z dnia 24.01.2022 M","categories":["environment"],"row_index":214,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Particle size distribution in the particle size range (2 – 2000) μm","parameters_en":[{"name":"Range","range":"(1 – 99)%"}],"search_en":"Ground, soil Particle size distribution in the particle size range (2 – 2000) μm Laser diffraction method Range PB-264/LF wyd. 2 z dnia 24.01.2022 M","technique_en":"Laser diffraction method","test_object_en":"Ground, soil","parameters_zh":[{"name":"范围","range":"(1 – 99)%"}],"search_zh":"土体、土壤 激光衍射法 范围 PB-264/LF wyd. 2 z dnia 24.01.2022 M","technique_zh":"激光衍射法","test_object_zh":"土体、土壤"},{"_id":"6a82c6ff884ede9a1b2c2a23","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Grunty, gleba","methodology":"Wodoprzepuszczalność - współczynnik filtracji","parameters":[{"name":"Zakres","range":"(9,0·10-8 – 1,0·10-2 ) m/s"},{"name":"(z obliczeń - USBSC)"}],"technique":null,"techniques":[],"computed":[],"activity":"Wodoprzepuszczalność - współczynnik filtracji\nZakres:\nZakres (9,0·10-8 – 1,0·10-2 ) m/s\n(z obliczeń - USBSC)","reference":"PB-62/LF wyd. 4 z dnia 24.01.2022 M","norm_bases":["PB-62/LF wyd. 4 z dnia 24.01.2022 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty, gleba Wodoprzepuszczalność - współczynnik filtracji\nZakres:\nZakres (9,0·10-8 – 1,0·10-2 ) m/s\n(z obliczeń - USBSC) PB-62/LF wyd. 4 z dnia 24.01.2022 M Grunty, gleba Wodoprzepuszczalnosc - wspolczynnik filtracji\nZakres:\nZakres (9,0·10-8 – 1,0·10-2 ) m/s\n(z obliczen - USBSC) PB-62/LF wyd. 4 z dnia 24.01.2022 M","categories":["environment"],"row_index":215,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water permeability - coefficient of permeability","parameters_en":[{"name":"Range","range":"(9,0·10-8 – 1,0·10-2 ) m/s"},{"name":"(calculated - USBSC)"}],"search_en":"Ground, soil Water permeability - coefficient of permeability Range (calculated - USBSC) PB-62/LF wyd. 4 z dnia 24.01.2022 M","test_object_en":"Ground, soil","parameters_zh":[{"name":"范围","range":"(9,0·10-8 – 1,0·10-2 ) m/s"},{"name":"（由计算得出 － USBSC）"}],"search_zh":"土体、土壤 透水性 － 渗透系数 范围 （由计算得出 － USBSC） PB-62/LF wyd. 4 z dnia 24.01.2022 M","methodology_zh":"透水性 － 渗透系数","test_object_zh":"土体、土壤"},{"_id":"6a82c6ff884ede9a1b2c2a24","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba (wyciąg glebowy)","methodology":"Zawartość azotu amonowego","parameters":[{"name":"Zakres","range":"(0,50 – 500) mg/kg"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Zawartość azotu amonowego\nZakres (0,50 – 500) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-ISO 14256-2:2010 M","norm_bases":["PN-ISO 14256-2:2010 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba (wyciąg glebowy) Zawartość azotu amonowego\nZakres (0,50 – 500) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-ISO 14256-2:2010 M Gleba (wyciag glebowy) Zawartosc azotu amonowego\nZakres (0,50 – 500) mg/kg\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-ISO 14256-2:2010 M","categories":["environment"],"row_index":216,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen content","parameters_en":[{"name":"Range","range":"(0,50 – 500) mg/kg"}],"search_en":"Soil (soil extract) Ammonium nitrogen content Continuous flow analysis (CFA) with spectrophotometric detection Range PN-ISO 14256-2:2010 M","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Soil (soil extract)","parameters_zh":[{"name":"范围","range":"(0,50 – 500) mg/kg"}],"search_zh":"土壤（土壤浸出液） 氨氮含量 连续流动分析（CFA）分光光度检测法 范围 PN-ISO 14256-2:2010 M","technique_zh":"连续流动分析（CFA）分光光度检测法","methodology_zh":"氨氮含量","test_object_zh":"土壤（土壤浸出液）"},{"_id":"6a82c6ff884ede9a1b2c2a25","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba (wyciąg glebowy)","methodology":"Zawartość azotu azotanowego","parameters":[{"name":"Zakres","range":"(1,0 – 500) mg/kg"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Zawartość azotu azotanowego\nZakres (1,0 – 500) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-ISO 14256-2:2010 M","norm_bases":["PN-ISO 14256-2:2010 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba (wyciąg glebowy) Zawartość azotu azotanowego\nZakres (1,0 – 500) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-ISO 14256-2:2010 M Gleba (wyciag glebowy) Zawartosc azotu azotanowego\nZakres (1,0 – 500) mg/kg\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-ISO 14256-2:2010 M","categories":["environment"],"row_index":217,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen content","parameters_en":[{"name":"Range","range":"(1,0 – 500) mg/kg"}],"search_en":"Soil (soil extract) Nitrate nitrogen content Continuous flow analysis (CFA) with spectrophotometric detection Range PN-ISO 14256-2:2010 M","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Soil (soil extract)","parameters_zh":[{"name":"范围","range":"(1,0 – 500) mg/kg"}],"search_zh":"土壤（土壤浸出液） 硝酸盐氮含量 连续流动分析（CFA）分光光度检测法 范围 PN-ISO 14256-2:2010 M","technique_zh":"连续流动分析（CFA）分光光度检测法","methodology_zh":"硝酸盐氮含量","test_object_zh":"土壤（土壤浸出液）"},{"_id":"6a82c6ff884ede9a1b2c2a26","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba (wyciąg glebowy)","methodology":"Zawartość azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,10 – 20) mg/kg"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Zawartość azotu azotynowego\nZakres (0,10 – 20) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-ISO 14256-2:2010 M","norm_bases":["PN-ISO 14256-2:2010 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba (wyciąg glebowy) Zawartość azotu azotynowego\nZakres (0,10 – 20) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-ISO 14256-2:2010 M Gleba (wyciag glebowy) Zawartosc azotu azotynowego\nZakres (0,10 – 20) mg/kg\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-ISO 14256-2:2010 M","categories":["environment"],"row_index":218,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen content","parameters_en":[{"name":"Range","range":"(0,10 – 20) mg/kg"}],"search_en":"Soil (soil extract) Nitrite nitrogen content Continuous flow analysis (CFA) with spectrophotometric detection Range PN-ISO 14256-2:2010 M","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Soil (soil extract)","parameters_zh":[{"name":"范围","range":"(0,10 – 20) mg/kg"}],"search_zh":"土壤（土壤浸出液） 亚硝酸盐氮含量 连续流动分析（CFA）分光光度检测法 范围 PN-ISO 14256-2:2010 M","technique_zh":"连续流动分析（CFA）分光光度检测法","methodology_zh":"亚硝酸盐氮含量","test_object_zh":"土壤（土壤浸出液）"},{"_id":"6a82c6ff884ede9a1b2c2a27","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba (wyciąg glebowy)","methodology":"Zawartość azotu mineralnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość azotu mineralnego (z obliczeń)","reference":"PN-ISO 14256-2:2010 M","norm_bases":["PN-ISO 14256-2:2010 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba (wyciąg glebowy) Zawartość azotu mineralnego (z obliczeń) PN-ISO 14256-2:2010 M Gleba (wyciag glebowy) Zawartosc azotu mineralnego (z obliczen) PN-ISO 14256-2:2010 M","categories":["environment"],"row_index":219,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral nitrogen content (calculated)","search_en":"Soil (soil extract) Mineral nitrogen content (calculated) PN-ISO 14256-2:2010 M","test_object_en":"Soil (soil extract)","methodology_zh":"矿质氮含量（由计算得出）","search_zh":"土壤（土壤浸出液） 矿质氮含量（由计算得出） PN-ISO 14256-2:2010 M","test_object_zh":"土壤（土壤浸出液）"},{"_id":"6a82c6ff884ede9a1b2c2a28","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Osad czynny","methodology":"Zawiesiny łatwoopadające (zdolność opadania osadu)","parameters":[{"name":"Zakres","range":"(100 – 1000) ml/l"}],"technique":"Metoda objętościowa","techniques":["Metoda objętościowa"],"computed":[],"activity":"Zawiesiny łatwoopadające (zdolność opadania osadu)\nZakres (100 – 1000) ml/l\nMetoda objętościowa","reference":"PN-EN 14702-1:2008 M","norm_bases":["PN-EN 14702-1:2008 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osad czynny Zawiesiny łatwoopadające (zdolność opadania osadu)\nZakres (100 – 1000) ml/l\nMetoda objętościowa PN-EN 14702-1:2008 M Osad czynny Zawiesiny latwoopadajace (zdolnosc opadania osadu)\nZakres (100 – 1000) ml/l\nMetoda objetosciowa PN-EN 14702-1:2008 M","categories":["water"],"row_index":220,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Settleable solids (sludge settleability)","parameters_en":[{"name":"Range","range":"(100 – 1000) ml/l"}],"search_en":"Activated sludge Settleable solids (sludge settleability) Volumetric method Range PN-EN 14702-1:2008 M","technique_en":"Volumetric method","test_object_en":"Activated sludge","parameters_zh":[{"name":"范围","range":"(100 – 1000) ml/l"}],"search_zh":"活性污泥 容量法 范围 PN-EN 14702-1:2008 M","technique_zh":"容量法","test_object_zh":"活性污泥"},{"_id":"6a82c6ff884ede9a1b2c2a29","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Osad czynny","methodology":"Indeks objętościowy osadu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks objętościowy osadu (z obliczeń)","reference":"PN-EN 14702-1:2008 M","norm_bases":["PN-EN 14702-1:2008 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osad czynny Indeks objętościowy osadu (z obliczeń) PN-EN 14702-1:2008 M Osad czynny Indeks objetosciowy osadu (z obliczen) PN-EN 14702-1:2008 M","categories":["water"],"row_index":221,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sludge volume index (calculated)","search_en":"Activated sludge Sludge volume index (calculated) PN-EN 14702-1:2008 M","test_object_en":"Activated sludge","search_zh":"活性污泥 污泥容积指数（由计算得出） PN-EN 14702-1:2008 M","test_object_zh":"活性污泥","methodology_zh":"污泥容积指数（由计算得出）"},{"_id":"6a82c6ff884ede9a1b2c2a2a","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Osad czynny","methodology":"Indeks gęstości osadu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks gęstości osadu (z obliczeń)","reference":"PN-EN 14702-1:2008 M","norm_bases":["PN-EN 14702-1:2008 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osad czynny Indeks gęstości osadu (z obliczeń) PN-EN 14702-1:2008 M Osad czynny Indeks gestosci osadu (z obliczen) PN-EN 14702-1:2008 M","categories":["water"],"row_index":222,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sludge density index (calculated)","search_en":"Activated sludge Sludge density index (calculated) PN-EN 14702-1:2008 M","test_object_en":"Activated sludge","search_zh":"活性污泥 PN-EN 14702-1:2008 M","test_object_zh":"活性污泥"},{"_id":"6a82c6ff884ede9a1b2c2a2b","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Osad czynny","methodology":"Zawiesiny","parameters":[{"name":"Zakres","range":"(1000 – 20 000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny\nZakres (1000 – 20 000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007 M","norm_bases":["PN-EN 872:2007","PN-EN 872:2007/Ap1:2007 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osad czynny Zawiesiny\nZakres (1000 – 20 000) mg/l\nMetoda wagowa PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007 M Osad czynny Zawiesiny\nZakres (1000 – 20 000) mg/l\nMetoda wagowa PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007 M","categories":["water"],"row_index":223,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Suspended solids","parameters_en":[{"name":"Range","range":"(1000 – 20 000) mg/l"}],"search_en":"Activated sludge Suspended solids Gravimetric method Range PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007 M","technique_en":"Gravimetric method","test_object_en":"Activated sludge","parameters_zh":[{"name":"范围","range":"(1000 – 20 000) mg/l"}],"search_zh":"活性污泥 重量法 范围 PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007 M","technique_zh":"重量法","test_object_zh":"活性污泥"},{"_id":"6a82c6ff884ede9a1b2c2a2c","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Sól (chlorek sodu), solanka, Środki do zwalczania śliskości zimowej","methodology":"Zawartość sodu","parameters":[{"name":"Zakres","range":"(0,40 - 39)%"},{"name":"Zawartość chlorku sodu (z obliczeń)"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość sodu\nZakres:\nZakres (0,40 - 39)%\nZawartość chlorku sodu (z obliczeń)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009 | PB-50/LF wyd. 2 z dnia 20.01.2022 M","norm_bases":["PN-EN ISO 11885:2009","PB-50/LF wyd. 2 z dnia 20.01.2022 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sól (chlorek sodu), solanka, Środki do zwalczania śliskości zimowej Zawartość sodu\nZakres:\nZakres (0,40 - 39)%\nZawartość chlorku sodu (z obliczeń)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 | PB-50/LF wyd. 2 z dnia 20.01.2022 M Sol (chlorek sodu), solanka, Srodki do zwalczania sliskosci zimowej Zawartosc sodu\nZakres:\nZakres (0,40 - 39)%\nZawartosc chlorku sodu (z obliczen)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009 | PB-50/LF wyd. 2 z dnia 20.01.2022 M","categories":["other"],"row_index":224,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sodium content","parameters_en":[{"name":"Range","range":"(0,40 - 39)%"},{"name":"Sodium chloride content (calculated)"}],"search_en":"Salt (sodium chloride), brine, Winter de-icing agents Sodium content Inductively coupled plasma optical emission spectrometry (ICP-OES) Range Sodium chloride content (calculated) PN-EN ISO 11885:2009 | PB-50/LF wyd. 2 z dnia 20.01.2022 M","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Salt (sodium chloride), brine, Winter de-icing agents","parameters_zh":[{"name":"范围","range":"(0,40 - 39)%"},{"name":"Zawartość chlorku sodu (z obliczeń)"}],"search_zh":"钠含量 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 PN-EN ISO 11885:2009 | PB-50/LF wyd. 2 z dnia 20.01.2022 M","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","methodology_zh":"钠含量"},{"_id":"6a82c6ff884ede9a1b2c2a2d","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Środki do zwalczania śliskości zimowej (sól, solanka)","methodology":"Zawartość chlorku sodu","parameters":[{"name":"Zakres","range":"(10 – 100) %"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Zawartość chlorku sodu\nZakres (10 – 100) %\nMetoda miareczkowania potencjometrycznego","reference":"PN-EN 16811-1:2016-10 M","norm_bases":["PN-EN 16811-1:2016-10 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środki do zwalczania śliskości zimowej (sól, solanka) Zawartość chlorku sodu\nZakres (10 – 100) %\nMetoda miareczkowania potencjometrycznego PN-EN 16811-1:2016-10 M Srodki do zwalczania sliskosci zimowej (sol, solanka) Zawartosc chlorku sodu\nZakres (10 – 100) %\nMetoda miareczkowania potencjometrycznego PN-EN 16811-1:2016-10 M","categories":["other"],"row_index":225,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sodium chloride content","parameters_en":[{"name":"Range","range":"(10 – 100) %"}],"search_en":"Winter de-icing agents (salt, brine) Sodium chloride content Potentiometric titration method Range PN-EN 16811-1:2016-10 M","technique_en":"Potentiometric titration method","test_object_en":"Winter de-icing agents (salt, brine)","parameters_zh":[{"name":"范围","range":"(10 – 100) %"}],"search_zh":"氯化钠含量 电位滴定法 范围 PN-EN 16811-1:2016-10 M","technique_zh":"电位滴定法","methodology_zh":"氯化钠含量"},{"_id":"6a82c6ff884ede9a1b2c2a2e","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Środki do zwalczania śliskości zimowej (sól)","methodology":"Zawartość heksacyjanożelazianu(II) potasu","parameters":[{"name":"Zakres","range":"(2,00 - 200) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość heksacyjanożelazianu(II) potasu\nZakres (2,00 - 200) mg/kg\nMetoda spektrofotometryczna","reference":"PN-EN 16811-1:2016-10 M","norm_bases":["PN-EN 16811-1:2016-10 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środki do zwalczania śliskości zimowej (sól) Zawartość heksacyjanożelazianu(II) potasu\nZakres (2,00 - 200) mg/kg\nMetoda spektrofotometryczna PN-EN 16811-1:2016-10 M Srodki do zwalczania sliskosci zimowej (sol) Zawartosc heksacyjanozelazianu(II) potasu\nZakres (2,00 - 200) mg/kg\nMetoda spektrofotometryczna PN-EN 16811-1:2016-10 M","categories":["other"],"row_index":226,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Potassium hexacyanoferrate(II) content","parameters_en":[{"name":"Range","range":"(2,00 - 200) mg/kg"}],"search_en":"Winter de-icing agents (salt) Potassium hexacyanoferrate(II) content Spectrophotometric method Range PN-EN 16811-1:2016-10 M","technique_en":"Spectrophotometric method","test_object_en":"Winter de-icing agents (salt)","parameters_zh":[{"name":"范围","range":"(2,00 - 200) mg/kg"}],"search_zh":"分光光度法 范围 PN-EN 16811-1:2016-10 M","technique_zh":"分光光度法"},{"_id":"6a82c6ff884ede9a1b2c2a2f","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Sól (chlorek sodu)","methodology":"Zawartość heksacyjanożelazianu(II) potasu","parameters":[{"name":"Zakres","range":"(2,00 - 200) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość heksacyjanożelazianu(II) potasu\nZakres (2,00 - 200) mg/kg\nMetoda spektrofotometryczna","reference":"PN-80/C-84081.40 M","norm_bases":["PN-80/C-84081.40 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sól (chlorek sodu) Zawartość heksacyjanożelazianu(II) potasu\nZakres (2,00 - 200) mg/kg\nMetoda spektrofotometryczna PN-80/C-84081.40 M Sol (chlorek sodu) Zawartosc heksacyjanozelazianu(II) potasu\nZakres (2,00 - 200) mg/kg\nMetoda spektrofotometryczna PN-80/C-84081.40 M","categories":["other"],"row_index":227,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Potassium hexacyanoferrate(II) content","parameters_en":[{"name":"Range","range":"(2,00 - 200) mg/kg"}],"search_en":"Salt (sodium chloride) Potassium hexacyanoferrate(II) content Spectrophotometric method Range PN-80/C-84081.40 M","technique_en":"Spectrophotometric method","test_object_en":"Salt (sodium chloride)","parameters_zh":[{"name":"范围","range":"(2,00 - 200) mg/kg"}],"search_zh":"盐（氯化钠） 分光光度法 范围 PN-80/C-84081.40 M","technique_zh":"分光光度法","test_object_zh":"盐（氯化钠）"},{"_id":"6a82c6ff884ede9a1b2c2a30","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Sól (chlorek sodu), środki do zwalczania śliskości zimowej (sól, solanka)","methodology":"pH","parameters":[{"name":"Zakres","range":"(2,0 – 12,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (2,0 – 12,0)\nMetoda potencjometryczna","reference":"PN-EN 16811-1:2016-10 pkt 7.10 | PN-EN ISO 10523:2012 M","norm_bases":["PN-EN 16811-1:2016-10 pkt 7.10","PN-EN ISO 10523:2012 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sól (chlorek sodu), środki do zwalczania śliskości zimowej (sól, solanka) pH\nZakres (2,0 – 12,0)\nMetoda potencjometryczna PN-EN 16811-1:2016-10 pkt 7.10 | PN-EN ISO 10523:2012 M Sol (chlorek sodu), srodki do zwalczania sliskosci zimowej (sol, solanka) pH\nZakres (2,0 – 12,0)\nMetoda potencjometryczna PN-EN 16811-1:2016-10 pkt 7.10 | PN-EN ISO 10523:2012 M","categories":["other"],"row_index":228,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"(2,0 – 12,0)"}],"search_en":"Salt (sodium chloride), winter de-icing agents (salt, brine) pH Potentiometric method Range PN-EN 16811-1:2016-10 pkt 7.10 | PN-EN ISO 10523:2012 M","technique_en":"Potentiometric method","test_object_en":"Salt (sodium chloride), winter de-icing agents (salt, brine)","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(2,0 – 12,0)"}],"search_zh":"pH 值 电位法 范围 PN-EN 16811-1:2016-10 pkt 7.10 | PN-EN ISO 10523:2012 M","technique_zh":"电位法"},{"_id":"6a82c6ff884ede9a1b2c2a31","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Sól (chlorek sodu), Środki do zwalczania śliskości zimowej (sól)","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,10 - 15,0)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wody\nZakres (0,10 - 15,0)%\nMetoda wagowa","reference":"PB-299/LF wyd.1 z dnia 11.01.2022 M","norm_bases":["PB-299/LF wyd.1 z dnia 11.01.2022 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sól (chlorek sodu), Środki do zwalczania śliskości zimowej (sól) Zawartość wody\nZakres (0,10 - 15,0)%\nMetoda wagowa PB-299/LF wyd.1 z dnia 11.01.2022 M Sol (chlorek sodu), Srodki do zwalczania sliskosci zimowej (sol) Zawartosc wody\nZakres (0,10 - 15,0)%\nMetoda wagowa PB-299/LF wyd.1 z dnia 11.01.2022 M","categories":["water"],"row_index":229,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(0,10 - 15,0)%"}],"search_en":"Salt (sodium chloride), De-icing agents for winter road maintenance (salt) Water content Gravimetric method Range PB-299/LF wyd.1 z dnia 11.01.2022 M","technique_en":"Gravimetric method","test_object_en":"Salt (sodium chloride), De-icing agents for winter road maintenance (salt)","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,10 - 15,0)%"}],"search_zh":"盐（氯化钠）、冬季防滑剂（盐） 水分含量 重量法 范围 PB-299/LF wyd.1 z dnia 11.01.2022 M","technique_zh":"重量法","test_object_zh":"盐（氯化钠）、冬季防滑剂（盐）"},{"_id":"6a82c6ff884ede9a1b2c2a32","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Sól (chlorek sodu), Środki do zwalczania śliskości zimowej (sól)","methodology":"Zawartość siarczanów","parameters":[{"name":"Zakres","range":"(0,10 – 5,0)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość siarczanów\nZakres (0,10 – 5,0)%\nMetoda wagowa","reference":"PN-80/C-84081.32 M","norm_bases":["PN-80/C-84081.32 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sól (chlorek sodu), Środki do zwalczania śliskości zimowej (sól) Zawartość siarczanów\nZakres (0,10 – 5,0)%\nMetoda wagowa PN-80/C-84081.32 M Sol (chlorek sodu), Srodki do zwalczania sliskosci zimowej (sol) Zawartosc siarczanow\nZakres (0,10 – 5,0)%\nMetoda wagowa PN-80/C-84081.32 M","categories":["other"],"row_index":230,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate content","parameters_en":[{"name":"Range","range":"(0,10 – 5,0)%"}],"search_en":"Salt (sodium chloride), De-icing agents for winter road maintenance (salt) Sulfate content Gravimetric method Range PN-80/C-84081.32 M","technique_en":"Gravimetric method","test_object_en":"Salt (sodium chloride), De-icing agents for winter road maintenance (salt)","parameters_zh":[{"name":"范围","range":"(0,10 – 5,0)%"}],"search_zh":"盐（氯化钠）、冬季防滑剂（盐） 硫酸盐含量 重量法 范围 PN-80/C-84081.32 M","technique_zh":"重量法","methodology_zh":"硫酸盐含量","test_object_zh":"盐（氯化钠）、冬季防滑剂（盐）"},{"_id":"6a82c6ff884ede9a1b2c2a33","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Sól (chlorek sodu), Środki do zwalczania śliskości zimowej (sól)","methodology":"Zawartość substancji nierozpuszczalnych w wodzie","parameters":[{"name":"Zakres","range":"(0,020 - 10)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość substancji nierozpuszczalnych w wodzie\nZakres (0,020 - 10)%\nMetoda wagowa","reference":"PN-80/C-84081/21 M","norm_bases":["PN-80/C-84081/21 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sól (chlorek sodu), Środki do zwalczania śliskości zimowej (sól) Zawartość substancji nierozpuszczalnych w wodzie\nZakres (0,020 - 10)%\nMetoda wagowa PN-80/C-84081/21 M Sol (chlorek sodu), Srodki do zwalczania sliskosci zimowej (sol) Zawartosc substancji nierozpuszczalnych w wodzie\nZakres (0,020 - 10)%\nMetoda wagowa PN-80/C-84081/21 M","categories":["other"],"row_index":231,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of water-insoluble substances","parameters_en":[{"name":"Range","range":"(0,020 - 10)%"}],"search_en":"Salt (sodium chloride), De-icing agents for winter road maintenance (salt) Content of water-insoluble substances Gravimetric method Range PN-80/C-84081/21 M","technique_en":"Gravimetric method","test_object_en":"Salt (sodium chloride), De-icing agents for winter road maintenance (salt)","parameters_zh":[{"name":"范围","range":"(0,020 - 10)%"}],"search_zh":"盐（氯化钠）、冬季防滑剂（盐） 水不溶物含量 重量法 范围 PN-80/C-84081/21 M","technique_zh":"重量法","methodology_zh":"水不溶物含量","test_object_zh":"盐（氯化钠）、冬季防滑剂（盐）"},{"_id":"6a82c6ff884ede9a1b2c2a34","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Środki do zwalczania śliskości zimowej (solanka)","methodology":"Gęstość (20°C)","parameters":[{"name":"Zakres","range":"(1,00 – 1,25) kg/dm3"}],"technique":"Metoda piknometryczna","techniques":["Metoda piknometryczna"],"computed":[],"activity":"Gęstość (20°C)\nZakres (1,00 – 1,25) kg/dm3\nMetoda piknometryczna","reference":"ISO 758:1976 M","norm_bases":["ISO 758:1976 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środki do zwalczania śliskości zimowej (solanka) Gęstość (20°C)\nZakres (1,00 – 1,25) kg/dm3\nMetoda piknometryczna ISO 758:1976 M Srodki do zwalczania sliskosci zimowej (solanka) Gestosc (20°C)\nZakres (1,00 – 1,25) kg/dm3\nMetoda piknometryczna ISO 758:1976 M","categories":["other"],"row_index":232,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density (20°C)","parameters_en":[{"name":"Range","range":"(1,00 – 1,25) kg/dm3"}],"search_en":"Winter de-icing agents (brine) Density (20°C) Pycnometric method Range ISO 758:1976 M","technique_en":"Pycnometric method","test_object_en":"Winter de-icing agents (brine)","parameters_zh":[{"name":"范围","range":"(1,00 – 1,25) kg/dm3"}],"search_zh":"比重瓶法 范围 ISO 758:1976 M","technique_zh":"比重瓶法"},{"_id":"6a82c6ff884ede9a1b2c2a35","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Środki do zwalczania śliskości zimowej","methodology":"Zawartość wapnia","parameters":[{"name":"Zakres","range":"(0,20 - 36)%"},{"name":"Zawartość chlorku wapnia (z obliczeń)"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość wapnia\nZakres:\nZakres (0,20 - 36)%\nZawartość chlorku wapnia (z obliczeń)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009 | PB-50/LF wyd. 2 z dnia 20.01.2022 M","norm_bases":["PN-EN ISO 11885:2009","PB-50/LF wyd. 2 z dnia 20.01.2022 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środki do zwalczania śliskości zimowej Zawartość wapnia\nZakres:\nZakres (0,20 - 36)%\nZawartość chlorku wapnia (z obliczeń)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 | PB-50/LF wyd. 2 z dnia 20.01.2022 M Srodki do zwalczania sliskosci zimowej Zawartosc wapnia\nZakres:\nZakres (0,20 - 36)%\nZawartosc chlorku wapnia (z obliczen)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009 | PB-50/LF wyd. 2 z dnia 20.01.2022 M","categories":["other"],"row_index":233,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Calcium content","parameters_en":[{"name":"Range","range":"(0,20 - 36)%"},{"name":"Calcium chloride content (calculated)"}],"search_en":"Winter de-icing and anti-skid materials Calcium content Inductively coupled plasma optical emission spectrometry (ICP-OES) Range Calcium chloride content (calculated) PN-EN ISO 11885:2009 | PB-50/LF wyd. 2 z dnia 20.01.2022 M","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Winter de-icing and anti-skid materials","parameters_zh":[{"name":"范围","range":"(0,20 - 36)%"},{"name":"Zawartość chlorku wapnia (z obliczeń)"}],"search_zh":"钙含量 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 PN-EN ISO 11885:2009 | PB-50/LF wyd. 2 z dnia 20.01.2022 M","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","methodology_zh":"钙含量"},{"_id":"6a82c6ff884ede9a1b2c2a36","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Sól (chlorek sodu), Środki do zwalczania śliskości zimowej (sól, kruszywo, piasek, żwir)","methodology":"Skład ziarnowy w zakresie wielkości cząstek (0,063 – 20) mm z podziałem na frakcje","parameters":[{"name":"Zakres","range":"(0,5 – 100) %"}],"technique":"Metoda sitowo-wagowa","techniques":["Metoda sitowo-wagowa"],"computed":[],"activity":"Skład ziarnowy w zakresie wielkości cząstek (0,063 – 20) mm z podziałem na frakcje\nZakres (0,5 – 100) %\nMetoda sitowo-wagowa","reference":"PB-38/LF wyd. 3 z dnia 24.01.2022 M","norm_bases":["PB-38/LF wyd. 3 z dnia 24.01.2022 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sól (chlorek sodu), Środki do zwalczania śliskości zimowej (sól, kruszywo, piasek, żwir) Skład ziarnowy w zakresie wielkości cząstek (0,063 – 20) mm z podziałem na frakcje\nZakres (0,5 – 100) %\nMetoda sitowo-wagowa PB-38/LF wyd. 3 z dnia 24.01.2022 M Sol (chlorek sodu), Srodki do zwalczania sliskosci zimowej (sol, kruszywo, piasek, zwir) Sklad ziarnowy w zakresie wielkosci czastek (0,063 – 20) mm z podzialem na frakcje\nZakres (0,5 – 100) %\nMetoda sitowo-wagowa PB-38/LF wyd. 3 z dnia 24.01.2022 M","categories":["construction"],"row_index":234,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Grain composition in the particle size range (0,063 – 20) mm divided into fractions","parameters_en":[{"name":"Range","range":"(0,5 – 100) %"}],"search_en":"Salt (sodium chloride), Winter de-icing and anti-skid materials (salt, aggregate, sand, gravel) Grain composition in the particle size range (0,063 – 20) mm divided into fractions Sieve-gravimetric method Range PB-38/LF wyd. 3 z dnia 24.01.2022 M","technique_en":"Sieve-gravimetric method","test_object_en":"Salt (sodium chloride), Winter de-icing and anti-skid materials (salt, aggregate, sand, gravel)","parameters_zh":[{"name":"范围","range":"(0,5 – 100) %"}],"search_zh":"筛析-重量法 范围 PB-38/LF wyd. 3 z dnia 24.01.2022 M","technique_zh":"筛析-重量法"},{"_id":"6a82c6ff884ede9a1b2c2a37","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Sól (chlorek sodu), Środki do zwalczania śliskości zimowej (sól, kruszywo, piasek, żwir)","methodology":"Gęstość nasypowa","parameters":[{"name":"Zakres","range":"(1,10 – 2,00) kg/dm3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Gęstość nasypowa\nZakres (1,10 – 2,00) kg/dm3\nMetoda wagowa","reference":"PB-41/LF wyd.3 z dnia 24.01.2022 M","norm_bases":["PB-41/LF wyd.3 z dnia 24.01.2022 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sól (chlorek sodu), Środki do zwalczania śliskości zimowej (sól, kruszywo, piasek, żwir) Gęstość nasypowa\nZakres (1,10 – 2,00) kg/dm3\nMetoda wagowa PB-41/LF wyd.3 z dnia 24.01.2022 M Sol (chlorek sodu), Srodki do zwalczania sliskosci zimowej (sol, kruszywo, piasek, zwir) Gestosc nasypowa\nZakres (1,10 – 2,00) kg/dm3\nMetoda wagowa PB-41/LF wyd.3 z dnia 24.01.2022 M","categories":["construction"],"row_index":235,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bulk density","parameters_en":[{"name":"Range","range":"(1,10 – 2,00) kg/dm3"}],"search_en":"Salt (sodium chloride), Winter de-icing and anti-skid materials (salt, aggregate, sand, gravel) Bulk density Gravimetric method Range PB-41/LF wyd.3 z dnia 24.01.2022 M","technique_en":"Gravimetric method","test_object_en":"Salt (sodium chloride), Winter de-icing and anti-skid materials (salt, aggregate, sand, gravel)","parameters_zh":[{"name":"范围","range":"(1,10 – 2,00) kg/dm3"}],"search_zh":"堆积密度 重量法 范围 PB-41/LF wyd.3 z dnia 24.01.2022 M","technique_zh":"重量法","methodology_zh":"堆积密度"},{"_id":"6a82c6ff884ede9a1b2c2a38","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne (SRF), surowce do produkcji paliw z odpadów, odpady do termicznego przekształcania zgodnie z rozporządzeniem, Ministra Środowiska Dz. U. 2016, poz. 847, Odpady kod: 01 04 81, 02 02 04, 02 04 80, 03 01 01, 03 01 04*, 03 01 05, 03 03 01, 03 03 11, 05 01 09*, 07 01 08*, 07 01 10*, 07 02 13, 07 02 80, 07 02 99, 07 03 01*, 07 05 13*, 10 01 01, 10 01 02, 10 01 15, 10 11 12, 15 01 01, 15 01 02, 15 01 03, 15 01 06, 16 01 20, 17 02 01, 17 02 03, 17 05 06, 17 06 04, 19 01 07*, 19 01 11*, 19 01 13*, 19 01 14, 19 03 05, 19 03 06*, 19 03 07, 19 05 03, 19 05 99, 19 06 06, 19 08 01, 19 08 02, 19 08 05, 19 08 12, 19 08 14, 19 12 01, 19 12 04, 19 12 07, 19 12 08, 19 12 10, 19 12 11*, 19 12 12, 20 01 01, 20 01 08, 20 01 99, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 07, 20 03 99","methodology":"Zawartość wilgoci całkowitej","parameters":[{"name":"Zakres","range":"(1,0 – 50,0)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci całkowitej\nZakres (1,0 – 50,0)%\nMetoda wagowa","reference":"CEN/TS 15414-1:2010 M","norm_bases":["CEN/TS 15414-1:2010 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwa wtórne (SRF), surowce do produkcji paliw z odpadów, odpady do termicznego przekształcania zgodnie z rozporządzeniem, Ministra Środowiska Dz. U. 2016, poz. 847, Odpady kod: 01 04 81, 02 02 04, 02 04 80, 03 01 01, 03 01 04*, 03 01 05, 03 03 01, 03 03 11, 05 01 09*, 07 01 08*, 07 01 10*, 07 02 13, 07 02 80, 07 02 99, 07 03 01*, 07 05 13*, 10 01 01, 10 01 02, 10 01 15, 10 11 12, 15 01 01, 15 01 02, 15 01 03, 15 01 06, 16 01 20, 17 02 01, 17 02 03, 17 05 06, 17 06 04, 19 01 07*, 19 01 11*, 19 01 13*, 19 01 14, 19 03 05, 19 03 06*, 19 03 07, 19 05 03, 19 05 99, 19 06 06, 19 08 01, 19 08 02, 19 08 05, 19 08 12, 19 08 14, 19 12 01, 19 12 04, 19 12 07, 19 12 08, 19 12 10, 19 12 11*, 19 12 12, 20 01 01, 20 01 08, 20 01 99, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 07, 20 03 99 Zawartość wilgoci całkowitej\nZakres (1,0 – 50,0)%\nMetoda wagowa CEN/TS 15414-1:2010 M Paliwa stale: stale paliwa wtorne (SRF), surowce do produkcji paliw z odpadow, odpady do termicznego przeksztalcania zgodnie z rozporzadzeniem, Ministra Srodowiska Dz. U. 2016, poz. 847, Odpady kod: 01 04 81, 02 02 04, 02 04 80, 03 01 01, 03 01 04*, 03 01 05, 03 03 01, 03 03 11, 05 01 09*, 07 01 08*, 07 01 10*, 07 02 13, 07 02 80, 07 02 99, 07 03 01*, 07 05 13*, 10 01 01, 10 01 02, 10 01 15, 10 11 12, 15 01 01, 15 01 02, 15 01 03, 15 01 06, 16 01 20, 17 02 01, 17 02 03, 17 05 06, 17 06 04, 19 01 07*, 19 01 11*, 19 01 13*, 19 01 14, 19 03 05, 19 03 06*, 19 03 07, 19 05 03, 19 05 99, 19 06 06, 19 08 01, 19 08 02, 19 08 05, 19 08 12, 19 08 14, 19 12 01, 19 12 04, 19 12 07, 19 12 08, 19 12 10, 19 12 11*, 19 12 12, 20 01 01, 20 01 08, 20 01 99, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 07, 20 03 99 Zawartosc wilgoci calkowitej\nZakres (1,0 – 50,0)%\nMetoda wagowa CEN/TS 15414-1:2010 M","categories":["environment","petro"],"row_index":236,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content","parameters_en":[{"name":"Range","range":"(1,0 – 50,0)%"}],"search_en":"Solid fuels: solid recovered fuels (SRF), raw materials for the production of fuels from waste, waste for thermal treatment in accordance with the Regulation of the Minister of the Environment, Dz. U. 2016, poz. 847, Waste code: 01 04 81, 02 02 04, 02 04 80, 03 01 01, 03 01 04*, 03 01 05, 03 03 01, 03 03 11, 05 01 09*, 07 01 08*, 07 01 10*, 07 02 13, 07 02 80, 07 02 99, 07 03 01*, 07 05 13*, 10 01 01, 10 01 02, 10 01 15, 10 11 12, 15 01 01, 15 01 02, 15 01 03, 15 01 06, 16 01 20, 17 02 01, 17 02 03, 17 05 06, 17 06 04, 19 01 07*, 19 01 11*, 19 01 13*, 19 01 14, 19 03 05, 19 03 06*, 19 03 07, 19 05 03, 19 05 99, 19 06 06, 19 08 01, 19 08 02, 19 08 05, 19 08 12, 19 08 14, 19 12 01, 19 12 04, 19 12 07, 19 12 08, 19 12 10, 19 12 11*, 19 12 12, 20 01 01, 20 01 08, 20 01 99, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 07, 20 03 99 Total moisture content Gravimetric method Range CEN/TS 15414-1:2010 M","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid recovered fuels (SRF), raw materials for the production of fuels from waste, waste for thermal treatment in accordance with the Regulation of the Minister of the Environment, Dz. U. 2016, poz. 847, Waste code: 01 04 81, 02 02 04, 02 04 80, 03 01 01, 03 01 04*, 03 01 05, 03 03 01, 03 03 11, 05 01 09*, 07 01 08*, 07 01 10*, 07 02 13, 07 02 80, 07 02 99, 07 03 01*, 07 05 13*, 10 01 01, 10 01 02, 10 01 15, 10 11 12, 15 01 01, 15 01 02, 15 01 03, 15 01 06, 16 01 20, 17 02 01, 17 02 03, 17 05 06, 17 06 04, 19 01 07*, 19 01 11*, 19 01 13*, 19 01 14, 19 03 05, 19 03 06*, 19 03 07, 19 05 03, 19 05 99, 19 06 06, 19 08 01, 19 08 02, 19 08 05, 19 08 12, 19 08 14, 19 12 01, 19 12 04, 19 12 07, 19 12 08, 19 12 10, 19 12 11*, 19 12 12, 20 01 01, 20 01 08, 20 01 99, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 07, 20 03 99","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 50,0)%"}],"search_zh":"全水分含量 重量法 范围 CEN/TS 15414-1:2010 M","technique_zh":"重量法"},{"_id":"6a82c6ff884ede9a1b2c2a39","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Nawozy organiczne, naturalne i mineralne, środki wspomagające uprawę roślin, w tym: środki poprawiające właściwości gleby, stymulatory wzrostu, podłoża do upraw","methodology":"pH w H2O","parameters":[{"name":"Zakres","range":"(2,0 – 12,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH w H2O\nZakres (2,0 – 12,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09 M","norm_bases":["PN-EN ISO 10390:2022-09 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy organiczne, naturalne i mineralne, środki wspomagające uprawę roślin, w tym: środki poprawiające właściwości gleby, stymulatory wzrostu, podłoża do upraw pH w H2O\nZakres (2,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 M Nawozy organiczne, naturalne i mineralne, srodki wspomagajace uprawe roslin, w tym: srodki poprawiajace wlasciwosci gleby, stymulatory wzrostu, podloza do upraw pH w H2O\nZakres (2,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 M","categories":["other"],"row_index":237,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH in H2O","parameters_en":[{"name":"Range","range":"(2,0 – 12,0)"}],"search_en":"Organic, natural and mineral fertilisers, plant cultivation aids, including: soil improvers, growth stimulators, growing media for cultivation pH in H2O Potentiometric method Range PN-EN ISO 10390:2022-09 M","technique_en":"Potentiometric method","test_object_en":"Organic, natural and mineral fertilisers, plant cultivation aids, including: soil improvers, growth stimulators, growing media for cultivation","methodology_zh":"水中 pH 值","parameters_zh":[{"name":"范围","range":"(2,0 – 12,0)"}],"search_zh":"有机肥、农家肥与矿物肥、植物栽培辅助制剂，其中包括：土壤改良剂、生长调节剂、栽培基质 水中 pH 值 电位法 范围 PN-EN ISO 10390:2022-09 M","technique_zh":"电位法","test_object_zh":"有机肥、农家肥与矿物肥、植物栽培辅助制剂，其中包括：土壤改良剂、生长调节剂、栽培基质"},{"_id":"6a82c6ff884ede9a1b2c2a3a","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Nawozy organiczne, naturalne i mineralne, środki wspomagające uprawę roślin, w tym: środki poprawiające właściwości gleby, stymulatory wzrostu, podłoża do upraw","methodology":"Zawartość suchej masy / zawartość wilgoci","parameters":[{"name":"Zakres","range":"(1,0 – 95,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość suchej masy / zawartość wilgoci\nZakres (1,0 – 95,0) %\nMetoda wagowa","reference":"PN-EN 12048:1999 M","norm_bases":["PN-EN 12048:1999 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy organiczne, naturalne i mineralne, środki wspomagające uprawę roślin, w tym: środki poprawiające właściwości gleby, stymulatory wzrostu, podłoża do upraw Zawartość suchej masy / zawartość wilgoci\nZakres (1,0 – 95,0) %\nMetoda wagowa PN-EN 12048:1999 M Nawozy organiczne, naturalne i mineralne, srodki wspomagajace uprawe roslin, w tym: srodki poprawiajace wlasciwosci gleby, stymulatory wzrostu, podloza do upraw Zawartosc suchej masy / zawartosc wilgoci\nZakres (1,0 – 95,0) %\nMetoda wagowa PN-EN 12048:1999 M","categories":["other"],"row_index":238,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter content / moisture content","parameters_en":[{"name":"Range","range":"(1,0 – 95,0) %"}],"search_en":"Organic, natural and mineral fertilisers, plant cultivation aids, including: soil improvers, growth stimulators, growing media for cultivation Dry matter content / moisture content Gravimetric method Range PN-EN 12048:1999 M","technique_en":"Gravimetric method","test_object_en":"Organic, natural and mineral fertilisers, plant cultivation aids, including: soil improvers, growth stimulators, growing media for cultivation","parameters_zh":[{"name":"范围","range":"(1,0 – 95,0) %"}],"search_zh":"有机肥、农家肥与矿物肥、植物栽培辅助制剂，其中包括：土壤改良剂、生长调节剂、栽培基质 重量法 范围 PN-EN 12048:1999 M","technique_zh":"重量法","test_object_zh":"有机肥、农家肥与矿物肥、植物栽培辅助制剂，其中包括：土壤改良剂、生长调节剂、栽培基质"},{"_id":"6a82c6ff884ede9a1b2c2a3b","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Nawozy organiczne, naturalne i mineralne, środki wspomagające uprawę roślin, w tym: środki poprawiające właściwości gleby, stymulatory wzrostu, podłoża do upraw","methodology":"Straty przy prażeniu suchej masy (LOI) / zawartość substancji organicznych","parameters":[{"name":"Zakres","range":"(1,0 – 95,0) %"},{"name":"Pozostałość po prażeniu / substancje mineralne (z obliczeń)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy (LOI) / zawartość substancji organicznych\nZakres:\nZakres (1,0 – 95,0) %\nPozostałość po prażeniu / substancje mineralne (z obliczeń)\nMetoda wagowa","reference":"PN-EN 15935:2022-01 M","norm_bases":["PN-EN 15935:2022-01 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy organiczne, naturalne i mineralne, środki wspomagające uprawę roślin, w tym: środki poprawiające właściwości gleby, stymulatory wzrostu, podłoża do upraw Straty przy prażeniu suchej masy (LOI) / zawartość substancji organicznych\nZakres:\nZakres (1,0 – 95,0) %\nPozostałość po prażeniu / substancje mineralne (z obliczeń)\nMetoda wagowa PN-EN 15935:2022-01 M Nawozy organiczne, naturalne i mineralne, srodki wspomagajace uprawe roslin, w tym: srodki poprawiajace wlasciwosci gleby, stymulatory wzrostu, podloza do upraw Straty przy prazeniu suchej masy (LOI) / zawartosc substancji organicznych\nZakres:\nZakres (1,0 – 95,0) %\nPozostalosc po prazeniu / substancje mineralne (z obliczen)\nMetoda wagowa PN-EN 15935:2022-01 M","categories":["other"],"row_index":239,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition of dry matter (LOI) / organic matter content","parameters_en":[{"name":"Range","range":"(1,0 – 95,0) %"},{"name":"Residue on ignition / mineral substances (calculated)"}],"search_en":"Organic, natural and mineral fertilisers, plant cultivation aids, including: soil improvers, growth stimulators, growing media for cultivation Loss on ignition of dry matter (LOI) / organic matter content Gravimetric method Range Residue on ignition / mineral substances (calculated) PN-EN 15935:2022-01 M","technique_en":"Gravimetric method","test_object_en":"Organic, natural and mineral fertilisers, plant cultivation aids, including: soil improvers, growth stimulators, growing media for cultivation","parameters_zh":[{"name":"范围","range":"(1,0 – 95,0) %"},{"name":"灼烧残渣/矿物质（由计算得出）"}],"search_zh":"有机肥、农家肥与矿物肥、植物栽培辅助制剂，其中包括：土壤改良剂、生长调节剂、栽培基质 干物质烧失量（LOI）/ 有机物质含量 重量法 范围 灼烧残渣/矿物质（由计算得出） PN-EN 15935:2022-01 M","technique_zh":"重量法","test_object_zh":"有机肥、农家肥与矿物肥、植物栽培辅助制剂，其中包括：土壤改良剂、生长调节剂、栽培基质","methodology_zh":"干物质烧失量（LOI）/ 有机物质含量"},{"_id":"6a82c6ff884ede9a1b2c2a3c","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Nawozy organiczne, naturalne i mineralne, środki wspomagające uprawę roślin, w tym: środki poprawiające właściwości gleby, stymulatory wzrostu, podłoża do upraw","methodology":"Zawartość azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,10 – 10) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu Kjeldahla\nZakres (0,10 – 10) %\nMetoda miareczkowa","reference":"PN-EN 16169:2012 M","norm_bases":["PN-EN 16169:2012 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy organiczne, naturalne i mineralne, środki wspomagające uprawę roślin, w tym: środki poprawiające właściwości gleby, stymulatory wzrostu, podłoża do upraw Zawartość azotu Kjeldahla\nZakres (0,10 – 10) %\nMetoda miareczkowa PN-EN 16169:2012 M Nawozy organiczne, naturalne i mineralne, srodki wspomagajace uprawe roslin, w tym: srodki poprawiajace wlasciwosci gleby, stymulatory wzrostu, podloza do upraw Zawartosc azotu Kjeldahla\nZakres (0,10 – 10) %\nMetoda miareczkowa PN-EN 16169:2012 M","categories":["other"],"row_index":240,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen content","parameters_en":[{"name":"Range","range":"(0,10 – 10) %"}],"search_en":"Organic, natural and mineral fertilisers, plant cultivation aids, including: soil improvers, growth stimulators, growing media for cultivation Kjeldahl nitrogen content Titrimetric method Range PN-EN 16169:2012 M","technique_en":"Titrimetric method","test_object_en":"Organic, natural and mineral fertilisers, plant cultivation aids, including: soil improvers, growth stimulators, growing media for cultivation","parameters_zh":[{"name":"范围","range":"(0,10 – 10) %"}],"search_zh":"有机肥、农家肥与矿物肥、植物栽培辅助制剂，其中包括：土壤改良剂、生长调节剂、栽培基质 凯氏氮含量 滴定法 范围 PN-EN 16169:2012 M","technique_zh":"滴定法","methodology_zh":"凯氏氮含量","test_object_zh":"有机肥、农家肥与矿物肥、植物栽培辅助制剂，其中包括：土壤改良剂、生长调节剂、栽培基质"},{"_id":"6a82c6ff884ede9a1b2c2a3d","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Nawozy organiczne, naturalne i mineralne, środki wspomagające uprawę roślin, w tym: środki poprawiające właściwości gleby, stymulatory wzrostu, podłoża do upraw","methodology":"Zawartość azotu amonowego","parameters":[{"name":"Zakres","range":"(0,050 – 2,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu amonowego\nZakres (0,050 – 2,0) %\nMetoda miareczkowa","reference":"PB-292/LF wyd. 2 z dnia 20.01.2022 M","norm_bases":["PB-292/LF wyd. 2 z dnia 20.01.2022 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy organiczne, naturalne i mineralne, środki wspomagające uprawę roślin, w tym: środki poprawiające właściwości gleby, stymulatory wzrostu, podłoża do upraw Zawartość azotu amonowego\nZakres (0,050 – 2,0) %\nMetoda miareczkowa PB-292/LF wyd. 2 z dnia 20.01.2022 M Nawozy organiczne, naturalne i mineralne, srodki wspomagajace uprawe roslin, w tym: srodki poprawiajace wlasciwosci gleby, stymulatory wzrostu, podloza do upraw Zawartosc azotu amonowego\nZakres (0,050 – 2,0) %\nMetoda miareczkowa PB-292/LF wyd. 2 z dnia 20.01.2022 M","categories":["other"],"row_index":241,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen content","parameters_en":[{"name":"Range","range":"(0,050 – 2,0) %"}],"search_en":"Organic, natural and mineral fertilisers, plant cultivation aids, including: soil improvers, growth stimulators, growing media for cultivation Ammonium nitrogen content Titrimetric method Range PB-292/LF wyd. 2 z dnia 20.01.2022 M","technique_en":"Titrimetric method","test_object_en":"Organic, natural and mineral fertilisers, plant cultivation aids, including: soil improvers, growth stimulators, growing media for cultivation","parameters_zh":[{"name":"范围","range":"(0,050 – 2,0) %"}],"search_zh":"有机肥、农家肥与矿物肥、植物栽培辅助制剂，其中包括：土壤改良剂、生长调节剂、栽培基质 氨氮含量 滴定法 范围 PB-292/LF wyd. 2 z dnia 20.01.2022 M","technique_zh":"滴定法","methodology_zh":"氨氮含量","test_object_zh":"有机肥、农家肥与矿物肥、植物栽培辅助制剂，其中包括：土壤改良剂、生长调节剂、栽培基质"},{"_id":"6a82c6ff884ede9a1b2c2a3e","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Nawozy organiczne, naturalne i mineralne, środki wspomagające uprawę roślin, w tym: środki poprawiające właściwości gleby, stymulatory wzrostu, podłoża do upraw","methodology":"Zawartość azotu całkowitego","parameters":[{"name":"Zakres","range":"(0,10 – 10) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu całkowitego\nZakres (0,10 – 10) %\nMetoda miareczkowa","reference":"PB-302/LF wyd. 2 z dnia 14.02.2023 M","norm_bases":["PB-302/LF wyd. 2 z dnia 14.02.2023 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy organiczne, naturalne i mineralne, środki wspomagające uprawę roślin, w tym: środki poprawiające właściwości gleby, stymulatory wzrostu, podłoża do upraw Zawartość azotu całkowitego\nZakres (0,10 – 10) %\nMetoda miareczkowa PB-302/LF wyd. 2 z dnia 14.02.2023 M Nawozy organiczne, naturalne i mineralne, srodki wspomagajace uprawe roslin, w tym: srodki poprawiajace wlasciwosci gleby, stymulatory wzrostu, podloza do upraw Zawartosc azotu calkowitego\nZakres (0,10 – 10) %\nMetoda miareczkowa PB-302/LF wyd. 2 z dnia 14.02.2023 M","categories":["other"],"row_index":242,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen content","parameters_en":[{"name":"Range","range":"(0,10 – 10) %"}],"search_en":"Organic, natural and mineral fertilisers, plant cultivation aids, including: soil improvers, growth stimulators, growing media for cultivation Total nitrogen content Titrimetric method Range PB-302/LF wyd. 2 z dnia 14.02.2023 M","technique_en":"Titrimetric method","test_object_en":"Organic, natural and mineral fertilisers, plant cultivation aids, including: soil improvers, growth stimulators, growing media for cultivation","parameters_zh":[{"name":"范围","range":"(0,10 – 10) %"}],"search_zh":"有机肥、农家肥与矿物肥、植物栽培辅助制剂，其中包括：土壤改良剂、生长调节剂、栽培基质 总氮含量 滴定法 范围 PB-302/LF wyd. 2 z dnia 14.02.2023 M","technique_zh":"滴定法","methodology_zh":"总氮含量","test_object_zh":"有机肥、农家肥与矿物肥、植物栽培辅助制剂，其中包括：土壤改良剂、生长调节剂、栽培基质"},{"_id":"6a82c6ff884ede9a1b2c2a3f","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Nawozy organiczne, naturalne i mineralne, środki wspomagające uprawę roślin, w tym: środki poprawiające właściwości gleby, stymulatory wzrostu, podłoża do upraw","methodology":"Zawartość pierwiastków","parameters":[{"name":"kadm","range":"(0,05 – 500) mg/kg"},{"name":"chrom","range":"(0,30 – 500) mg/kg"},{"name":"ołów","range":"(1,0 – 300) mg/kg"},{"name":"nikiel","range":"(0,40 – 200) mg/kg"},{"name":"miedź","range":"(0,40 – 1500) mg/kg"},{"name":"cynk","range":"(0,50 – 2000) mg/kg"},{"name":"wapń","range":"(1,0 – 150 000) mg/kg"},{"name":"magnez","range":"(0,70 – 40 000) mg/kg"},{"name":"potas","range":"(100 – 150 000) mg/kg"},{"name":"sód","range":"(100 – 30 000) mg/kg"},{"name":"fosfor","range":"(5,0 – 25 000) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze w zbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze w zbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\nkadm (0,05 – 500) mg/kg\nchrom (0,30 – 500) mg/kg\nołów (1,0 – 300) mg/kg\nnikiel (0,40 – 200) mg/kg\nmiedź (0,40 – 1500) mg/kg\ncynk (0,50 – 2000) mg/kg\nwapń (1,0 – 150 000) mg/kg\nmagnez (0,70 – 40 000) mg/kg\npotas (100 – 150 000) mg/kg\nsód (100 – 30 000) mg/kg\nfosfor (5,0 – 25 000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze w zbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 16319+A1:2016-02 M","norm_bases":["PN-EN 16319+A1:2016-02 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy organiczne, naturalne i mineralne, środki wspomagające uprawę roślin, w tym: środki poprawiające właściwości gleby, stymulatory wzrostu, podłoża do upraw Zawartość pierwiastków\nZakres:\nkadm (0,05 – 500) mg/kg\nchrom (0,30 – 500) mg/kg\nołów (1,0 – 300) mg/kg\nnikiel (0,40 – 200) mg/kg\nmiedź (0,40 – 1500) mg/kg\ncynk (0,50 – 2000) mg/kg\nwapń (1,0 – 150 000) mg/kg\nmagnez (0,70 – 40 000) mg/kg\npotas (100 – 150 000) mg/kg\nsód (100 – 30 000) mg/kg\nfosfor (5,0 – 25 000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze w zbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 16319+A1:2016-02 M Nawozy organiczne, naturalne i mineralne, srodki wspomagajace uprawe roslin, w tym: srodki poprawiajace wlasciwosci gleby, stymulatory wzrostu, podloza do upraw Zawartosc pierwiastkow\nZakres:\nkadm (0,05 – 500) mg/kg\nchrom (0,30 – 500) mg/kg\nolow (1,0 – 300) mg/kg\nnikiel (0,40 – 200) mg/kg\nmiedz (0,40 – 1500) mg/kg\ncynk (0,50 – 2000) mg/kg\nwapn (1,0 – 150 000) mg/kg\nmagnez (0,70 – 40 000) mg/kg\npotas (100 – 150 000) mg/kg\nsod (100 – 30 000) mg/kg\nfosfor (5,0 – 25 000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze w zbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 16319+A1:2016-02 M","categories":["materials"],"row_index":243,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","parameters_en":[{"name":"cadmium","range":"(0,05 – 500) mg/kg"},{"name":"chromium","range":"(0,30 – 500) mg/kg"},{"name":"lead","range":"(1,0 – 300) mg/kg"},{"name":"nickel","range":"(0,40 – 200) mg/kg"},{"name":"copper","range":"(0,40 – 1500) mg/kg"},{"name":"zinc","range":"(0,50 – 2000) mg/kg"},{"name":"calcium","range":"(1,0 – 150 000) mg/kg"},{"name":"magnesium","range":"(0,70 – 40 000) mg/kg"},{"name":"potassium","range":"(100 – 150 000) mg/kg"},{"name":"sodium","range":"(100 – 30 000) mg/kg"},{"name":"phosphorus","range":"(5,0 – 25 000) mg/kg"}],"search_en":"Organic, natural and mineral fertilisers, plant cultivation aids, including: soil improvers, growth stimulators, growing media for cultivation Element content Inductively coupled plasma atomic emission spectrometry (ICP-OES) cadmium chromium lead nickel copper zinc calcium magnesium potassium sodium phosphorus PN-EN 16319+A1:2016-02 M","technique_en":"Inductively coupled plasma atomic emission spectrometry (ICP-OES)","test_object_en":"Organic, natural and mineral fertilisers, plant cultivation aids, including: soil improvers, growth stimulators, growing media for cultivation","methodology_zh":"元素含量","parameters_zh":[{"name":"镉","range":"(0,05 – 500) mg/kg"},{"name":"铬","range":"(0,30 – 500) mg/kg"},{"name":"铅","range":"(1,0 – 300) mg/kg"},{"name":"镍","range":"(0,40 – 200) mg/kg"},{"name":"铜","range":"(0,40 – 1500) mg/kg"},{"name":"锌","range":"(0,50 – 2000) mg/kg"},{"name":"钙","range":"(1,0 – 150 000) mg/kg"},{"name":"镁","range":"(0,70 – 40 000) mg/kg"},{"name":"钾","range":"(100 – 150 000) mg/kg"},{"name":"钠","range":"(100 – 30 000) mg/kg"},{"name":"磷","range":"(5,0 – 25 000) mg/kg"}],"search_zh":"有机肥、农家肥与矿物肥、植物栽培辅助制剂，其中包括：土壤改良剂、生长调节剂、栽培基质 元素含量 镉 铬 铅 镍 铜 锌 钙 镁 钾 钠 磷 PN-EN 16319+A1:2016-02 M","test_object_zh":"有机肥、农家肥与矿物肥、植物栽培辅助制剂，其中包括：土壤改良剂、生长调节剂、栽培基质"},{"_id":"6a82c6ff884ede9a1b2c2a40","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Nawozy organiczne, naturalne i mineralne, środki wspomagające uprawę roślin, w tym: środki poprawiające właściwości gleby, stymulatory wzrostu, podłoża do upraw","methodology":"Zawartość arsenu","parameters":[{"name":"Zakres","range":"(2,0 - 10) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość arsenu\nZakres (2,0 - 10) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885 :2009 | IB-114/LF-PD wyd. 1 z dnia 14.02.2023 M","norm_bases":["PN-EN ISO 11885 :2009","IB-114/LF-PD wyd. 1 z dnia 14.02.2023 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy organiczne, naturalne i mineralne, środki wspomagające uprawę roślin, w tym: środki poprawiające właściwości gleby, stymulatory wzrostu, podłoża do upraw Zawartość arsenu\nZakres (2,0 - 10) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885 :2009 | IB-114/LF-PD wyd. 1 z dnia 14.02.2023 M Nawozy organiczne, naturalne i mineralne, srodki wspomagajace uprawe roslin, w tym: srodki poprawiajace wlasciwosci gleby, stymulatory wzrostu, podloza do upraw Zawartosc arsenu\nZakres (2,0 - 10) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885 :2009 | IB-114/LF-PD wyd. 1 z dnia 14.02.2023 M","categories":["other"],"row_index":244,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Arsenic content","parameters_en":[{"name":"Range","range":"(2,0 - 10) mg/kg"}],"search_en":"Organic, natural and mineral fertilisers, plant cultivation aids, including: soil improvers, growth stimulators, growing media for cultivation Arsenic content Inductively coupled plasma optical emission spectrometry (ICP-OES) Range PN-EN ISO 11885 :2009 | IB-114/LF-PD wyd. 1 z dnia 14.02.2023 M","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Organic, natural and mineral fertilisers, plant cultivation aids, including: soil improvers, growth stimulators, growing media for cultivation","parameters_zh":[{"name":"范围","range":"(2,0 - 10) mg/kg"}],"search_zh":"有机肥、农家肥与矿物肥、植物栽培辅助制剂，其中包括：土壤改良剂、生长调节剂、栽培基质 砷含量 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 PN-EN ISO 11885 :2009 | IB-114/LF-PD wyd. 1 z dnia 14.02.2023 M","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","methodology_zh":"砷含量","test_object_zh":"有机肥、农家肥与矿物肥、植物栽培辅助制剂，其中包括：土壤改良剂、生长调节剂、栽培基质"},{"_id":"6a82c6ff884ede9a1b2c2a41","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Nawozy organiczne, naturalne i mineralne, środki wspomagające uprawę roślin, w tym: środki poprawiające właściwości gleby, stymulatory wzrostu, podłoża do upraw","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,10 – 100) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN 16320+A1:2017-04 M","norm_bases":["PN-EN 16320+A1:2017-04 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy organiczne, naturalne i mineralne, środki wspomagające uprawę roślin, w tym: środki poprawiające właściwości gleby, stymulatory wzrostu, podłoża do upraw Zawartość rtęci\nZakres (0,10 – 100) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 16320+A1:2017-04 M Nawozy organiczne, naturalne i mineralne, srodki wspomagajace uprawe roslin, w tym: srodki poprawiajace wlasciwosci gleby, stymulatory wzrostu, podloza do upraw Zawartosc rteci\nZakres (0,10 – 100) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 16320+A1:2017-04 M","categories":["other"],"row_index":245,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/kg"}],"search_en":"Organic, natural and mineral fertilisers, plant cultivation aids, including: soil improvers, growth stimulators, growing media for cultivation Mercury content Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN 16320+A1:2017-04 M","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"Organic, natural and mineral fertilisers, plant cultivation aids, including: soil improvers, growth stimulators, growing media for cultivation","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/kg"}],"search_zh":"有机肥、农家肥与矿物肥、植物栽培辅助制剂，其中包括：土壤改良剂、生长调节剂、栽培基质 汞含量 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN 16320+A1:2017-04 M","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"有机肥、农家肥与矿物肥、植物栽培辅助制剂，其中包括：土壤改良剂、生长调节剂、栽培基质"},{"_id":"6a82c6ff884ede9a1b2c2a42","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Nawozy organiczne, naturalne i mineralne, środki wspomagające uprawę roślin, w tym: środki poprawiające właściwości gleby, stymulatory wzrostu, podłoża do upraw","methodology":"Całkowita zawartość węgla","parameters":[{"name":"Zakres","range":"(1,0 – 95,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Całkowita zawartość węgla\nZakres (1,0 – 95,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PB-76/LF wyd. 2 z dnia 20.01.2022 M","norm_bases":["PB-76/LF wyd. 2 z dnia 20.01.2022 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy organiczne, naturalne i mineralne, środki wspomagające uprawę roślin, w tym: środki poprawiające właściwości gleby, stymulatory wzrostu, podłoża do upraw Całkowita zawartość węgla\nZakres (1,0 – 95,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PB-76/LF wyd. 2 z dnia 20.01.2022 M Nawozy organiczne, naturalne i mineralne, srodki wspomagajace uprawe roslin, w tym: srodki poprawiajace wlasciwosci gleby, stymulatory wzrostu, podloza do upraw Calkowita zawartosc wegla\nZakres (1,0 – 95,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PB-76/LF wyd. 2 z dnia 20.01.2022 M","categories":["other"],"row_index":246,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(1,0 – 95,0) %"}],"search_en":"Organic, natural and mineral fertilisers, plant cultivation aids, including: soil improvers, growth stimulators, growing media for cultivation Total carbon content High-temperature combustion with IR detection Range PB-76/LF wyd. 2 z dnia 20.01.2022 M","technique_en":"High-temperature combustion with IR detection","test_object_en":"Organic, natural and mineral fertilisers, plant cultivation aids, including: soil improvers, growth stimulators, growing media for cultivation","parameters_zh":[{"name":"范围","range":"(1,0 – 95,0) %"}],"search_zh":"有机肥、农家肥与矿物肥、植物栽培辅助制剂，其中包括：土壤改良剂、生长调节剂、栽培基质 高温燃烧红外检测法 范围 PB-76/LF wyd. 2 z dnia 20.01.2022 M","technique_zh":"高温燃烧红外检测法","test_object_zh":"有机肥、农家肥与矿物肥、植物栽培辅助制剂，其中包括：土壤改良剂、生长调节剂、栽培基质"},{"_id":"6a82c6ff884ede9a1b2c2a43","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Nawozy organiczne, naturalne i mineralne, środki wspomagające uprawę roślin, w tym: środki poprawiające właściwości gleby, stymulatory wzrostu, podłoża do upraw","methodology":"Stosunek C/N (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stosunek C/N (z obliczeń)","reference":"M","norm_bases":["M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy organiczne, naturalne i mineralne, środki wspomagające uprawę roślin, w tym: środki poprawiające właściwości gleby, stymulatory wzrostu, podłoża do upraw Stosunek C/N (z obliczeń) M Nawozy organiczne, naturalne i mineralne, srodki wspomagajace uprawe roslin, w tym: srodki poprawiajace wlasciwosci gleby, stymulatory wzrostu, podloza do upraw Stosunek C/N (z obliczen) M","categories":["other"],"row_index":247,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"C/N ratio (calculated)","search_en":"Organic, natural and mineral fertilisers, plant cultivation aids, including: soil improvers, growth stimulators, growing media for cultivation C/N ratio (calculated) M","test_object_en":"Organic, natural and mineral fertilisers, plant cultivation aids, including: soil improvers, growth stimulators, growing media for cultivation","search_zh":"有机肥、农家肥与矿物肥、植物栽培辅助制剂，其中包括：土壤改良剂、生长调节剂、栽培基质 M","test_object_zh":"有机肥、农家肥与矿物肥、植物栽培辅助制剂，其中包括：土壤改良剂、生长调节剂、栽培基质"},{"_id":"6a82c6ff884ede9a1b2c2a44","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Nawozy organiczne, naturalne i mineralne, środki wspomagające uprawę roślin, w tym: środki poprawiające właściwości gleby, stymulatory wzrostu, podłoża do upraw","methodology":"Całkowita zawartość węgla (TC)","parameters":[{"name":"Zakres","range":"(0,50 – 70) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Całkowita zawartość węgla (TC)\nZakres (0,50 – 70) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 15936:2022-07 metoda A M","norm_bases":["PN-EN 15936:2022-07 metoda A M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy organiczne, naturalne i mineralne, środki wspomagające uprawę roślin, w tym: środki poprawiające właściwości gleby, stymulatory wzrostu, podłoża do upraw Całkowita zawartość węgla (TC)\nZakres (0,50 – 70) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 15936:2022-07 metoda A M Nawozy organiczne, naturalne i mineralne, srodki wspomagajace uprawe roslin, w tym: srodki poprawiajace wlasciwosci gleby, stymulatory wzrostu, podloza do upraw Calkowita zawartosc wegla (TC)\nZakres (0,50 – 70) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 15936:2022-07 metoda A M","categories":["other"],"row_index":248,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content (TC)","parameters_en":[{"name":"Range","range":"(0,50 – 70) %"}],"search_en":"Organic, natural and mineral fertilisers, plant cultivation aids, including: soil improvers, growth stimulators, growing media for cultivation Total carbon content (TC) High-temperature combustion with IR detection Range PN-EN 15936:2022-07 metoda A M","technique_en":"High-temperature combustion with IR detection","test_object_en":"Organic, natural and mineral fertilisers, plant cultivation aids, including: soil improvers, growth stimulators, growing media for cultivation","parameters_zh":[{"name":"范围","range":"(0,50 – 70) %"}],"search_zh":"有机肥、农家肥与矿物肥、植物栽培辅助制剂，其中包括：土壤改良剂、生长调节剂、栽培基质 高温燃烧红外检测法 范围 PN-EN 15936:2022-07 metoda A M","technique_zh":"高温燃烧红外检测法","test_object_zh":"有机肥、农家肥与矿物肥、植物栽培辅助制剂，其中包括：土壤改良剂、生长调节剂、栽培基质"},{"_id":"6a82c6ff884ede9a1b2c2a45","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Nawozy organiczne, naturalne i mineralne, środki wspomagające uprawę roślin, w tym: środki poprawiające właściwości gleby, stymulatory wzrostu, podłoża do upraw","methodology":"Zawartość węgla nieorganicznego (TIC)","parameters":[{"name":"Zakres","range":"(0,50 – 12) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla nieorganicznego (TIC)\nZakres (0,50 – 12) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 15936:2022-07 metoda A M","norm_bases":["PN-EN 15936:2022-07 metoda A M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy organiczne, naturalne i mineralne, środki wspomagające uprawę roślin, w tym: środki poprawiające właściwości gleby, stymulatory wzrostu, podłoża do upraw Zawartość węgla nieorganicznego (TIC)\nZakres (0,50 – 12) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 15936:2022-07 metoda A M Nawozy organiczne, naturalne i mineralne, srodki wspomagajace uprawe roslin, w tym: srodki poprawiajace wlasciwosci gleby, stymulatory wzrostu, podloza do upraw Zawartosc wegla nieorganicznego (TIC)\nZakres (0,50 – 12) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 15936:2022-07 metoda A M","categories":["other"],"row_index":249,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Inorganic carbon content (TIC)","parameters_en":[{"name":"Range","range":"(0,50 – 12) %"}],"search_en":"Organic, natural and mineral fertilisers, plant cultivation aids, including: soil improvers, growth stimulators, growing media for cultivation Inorganic carbon content (TIC) High-temperature combustion with IR detection Range PN-EN 15936:2022-07 metoda A M","technique_en":"High-temperature combustion with IR detection","test_object_en":"Organic, natural and mineral fertilisers, plant cultivation aids, including: soil improvers, growth stimulators, growing media for cultivation","parameters_zh":[{"name":"范围","range":"(0,50 – 12) %"}],"search_zh":"有机肥、农家肥与矿物肥、植物栽培辅助制剂，其中包括：土壤改良剂、生长调节剂、栽培基质 高温燃烧红外检测法 范围 PN-EN 15936:2022-07 metoda A M","technique_zh":"高温燃烧红外检测法","test_object_zh":"有机肥、农家肥与矿物肥、植物栽培辅助制剂，其中包括：土壤改良剂、生长调节剂、栽培基质"},{"_id":"6a82c6ff884ede9a1b2c2a46","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Nawozy organiczne, naturalne i mineralne, środki wspomagające uprawę roślin, w tym: środki poprawiające właściwości gleby, stymulatory wzrostu, podłoża do upraw","methodology":"Zawartość ogólnego węgla organicznego (TOC) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość ogólnego węgla organicznego (TOC) (z obliczeń)","reference":"PN-EN 15936:2022-07 metoda A M","norm_bases":["PN-EN 15936:2022-07 metoda A M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy organiczne, naturalne i mineralne, środki wspomagające uprawę roślin, w tym: środki poprawiające właściwości gleby, stymulatory wzrostu, podłoża do upraw Zawartość ogólnego węgla organicznego (TOC) (z obliczeń) PN-EN 15936:2022-07 metoda A M Nawozy organiczne, naturalne i mineralne, srodki wspomagajace uprawe roslin, w tym: srodki poprawiajace wlasciwosci gleby, stymulatory wzrostu, podloza do upraw Zawartosc ogolnego wegla organicznego (TOC) (z obliczen) PN-EN 15936:2022-07 metoda A M","categories":["other"],"row_index":250,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon content (TOC) (calculated)","search_en":"Organic, natural and mineral fertilisers, plant cultivation aids, including: soil improvers, growth stimulators, growing media for cultivation Total organic carbon content (TOC) (calculated) PN-EN 15936:2022-07 metoda A M","test_object_en":"Organic, natural and mineral fertilisers, plant cultivation aids, including: soil improvers, growth stimulators, growing media for cultivation","search_zh":"有机肥、农家肥与矿物肥、植物栽培辅助制剂，其中包括：土壤改良剂、生长调节剂、栽培基质 总有机碳（TOC）含量（由计算得出） PN-EN 15936:2022-07 metoda A M","test_object_zh":"有机肥、农家肥与矿物肥、植物栽培辅助制剂，其中包括：土壤改良剂、生长调节剂、栽培基质","methodology_zh":"总有机碳（TOC）含量（由计算得出）"},{"_id":"6a82c6ff884ede9a1b2c2a47","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E, Ścieki E, Gleba E, Grunty E","methodology":"Stężenie/zawartość lotnych związków chlorowcoorganicznych (VOX)","parameters":[],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)"],"computed":[],"activity":"Stężenie/zawartość lotnych związków chlorowcoorganicznych (VOX)\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E, Ścieki E, Gleba E, Grunty E Stężenie/zawartość lotnych związków chlorowcoorganicznych (VOX)\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) Normy M Woda E, Woda do spozycia przez ludzi E, Scieki E, Gleba E, Grunty E Stezenie/zawartosc lotnych zwiazkow chlorowcoorganicznych (VOX)\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) Normy M","categories":["water","environment"],"row_index":251,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) Normy M","technique_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","search_zh":"顶空气相色谱-质谱法（HS-GC-MS） Normy M","technique_zh":"顶空气相色谱-质谱法（HS-GC-MS）"},{"_id":"6a82c6ff884ede9a1b2c2a48","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E, Ścieki E, Gleba E, Grunty E","methodology":"Stężenie/zawartość środków ochrony roślin (pestycydów)","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Stężenie/zawartość środków ochrony roślin (pestycydów)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E, Ścieki E, Gleba E, Grunty E Stężenie/zawartość środków ochrony roślin (pestycydów)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) Normy M Woda E, Woda do spozycia przez ludzi E, Scieki E, Gleba E, Grunty E Stezenie/zawartosc srodkow ochrony roslin (pestycydow)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) Normy M","categories":["water","environment"],"row_index":252,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Gas chromatography with mass spectrometry detection (GC-MS) Normy M","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","search_zh":"气相色谱-质谱法（GC-MS） Normy M","technique_zh":"气相色谱-质谱法（GC-MS）"},{"_id":"6a82c6ff884ede9a1b2c2a49","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E, Ścieki E, Gleba E, Grunty E","methodology":"Stężenie/zawartość środków ochrony roślin (pestycydów)","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"computed":[],"activity":"Stężenie/zawartość środków ochrony roślin (pestycydów)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E, Ścieki E, Gleba E, Grunty E Stężenie/zawartość środków ochrony roślin (pestycydów)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) Normy M Woda E, Woda do spozycia przez ludzi E, Scieki E, Gleba E, Grunty E Stezenie/zawartosc srodkow ochrony roslin (pestycydow)\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) Normy M","categories":["water","environment"],"row_index":253,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Gas chromatography with electron capture detection (GC-ECD) Normy M","technique_en":"Gas chromatography with electron capture detection (GC-ECD)","search_zh":"气相色谱-电子捕获检测法（GC-ECD） Normy M","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）"},{"_id":"6a82c6ff884ede9a1b2c2a4a","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E, Ścieki E, Gleba E, Grunty E, Piasek E, Osady ściekowe E","methodology":"Indeks oleju mineralnego/ zawartość oleju mineralnego (węglowodory ropopochodne / rozpuszczone lub zemulgowane węglowodory) (substancje ropopochodne)","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Indeks oleju mineralnego/ zawartość oleju mineralnego (węglowodory ropopochodne / rozpuszczone lub zemulgowane węglowodory) (substancje ropopochodne)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E, Ścieki E, Gleba E, Grunty E, Piasek E, Osady ściekowe E Indeks oleju mineralnego/ zawartość oleju mineralnego (węglowodory ropopochodne / rozpuszczone lub zemulgowane węglowodory) (substancje ropopochodne)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy M Woda E, Woda do spozycia przez ludzi E, Scieki E, Gleba E, Grunty E, Piasek E, Osady sciekowe E Indeks oleju mineralnego/ zawartosc oleju mineralnego (weglowodory ropopochodne / rozpuszczone lub zemulgowane weglowodory) (substancje ropopochodne)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy M","categories":["water","environment","petro"],"row_index":254,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Gas chromatography with flame ionization detection (GC-FID) Normy M","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） Normy M","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a82c6ff884ede9a1b2c2a4b","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E, Ścieki E, Gleba E, Grunty E, Piasek E, Osady ściekowe E, Osady denne E, Mieszanki mineralno-asfaltowe: destrukt asfaltowy E","methodology":"Stężenie/zawartość pierwiastków","parameters":[],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie/zawartość pierwiastków\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E, Ścieki E, Gleba E, Grunty E, Piasek E, Osady ściekowe E, Osady denne E, Mieszanki mineralno-asfaltowe: destrukt asfaltowy E Stężenie/zawartość pierwiastków\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Normy M Woda E, Woda do spozycia przez ludzi E, Scieki E, Gleba E, Grunty E, Piasek E, Osady sciekowe E, Osady denne E, Mieszanki mineralno-asfaltowe: destrukt asfaltowy E Stezenie/zawartosc pierwiastkow\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Normy M","categories":["water","environment"],"row_index":255,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration/content","search_en":"Element concentration/content Inductively coupled plasma optical emission spectrometry (ICP-OES) Normy M","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","search_zh":"元素的浓度/含量 电感耦合等离子体原子发射光谱法（ICP-OES） Normy M","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","methodology_zh":"元素的浓度/含量"},{"_id":"6a82c6ff884ede9a1b2c2a4c","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda E , Woda do spożycia przez ludzi E, Ścieki E,","methodology":"Stężenie pierwiastków","parameters":[],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Stężenie pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda E , Woda do spożycia przez ludzi E, Ścieki E, Stężenie pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) Normy M Woda E , Woda do spozycia przez ludzi E, Scieki E, Stezenie pierwiastkow\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) Normy M","categories":["water"],"row_index":256,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","search_en":"Element concentration Inductively coupled plasma mass spectrometry (ICP-MS) Normy M","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","methodology_zh":"元素浓度","search_zh":"元素浓度 电感耦合等离子体质谱法（ICP-MS） Normy M","technique_zh":"电感耦合等离子体质谱法（ICP-MS）"},{"_id":"6a82c6ff884ede9a1b2c2a4d","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E, Ścieki E, Gleba E, Grunty E, Osady ściekowe E, Osady denne E, Mieszanki mineralno-asfaltowe: destrukt asfaltowy E","methodology":"Stężenie/zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,0001 – 1,00) mg/l"},{"name":"Zakres","range":"(0,10 – 100) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Stężenie/zawartość rtęci\nZakres:\nZakres (0,0001 – 1,00) mg/l\nZakres (0,10 – 100) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E, Ścieki E, Gleba E, Grunty E, Osady ściekowe E, Osady denne E, Mieszanki mineralno-asfaltowe: destrukt asfaltowy E Stężenie/zawartość rtęci\nZakres:\nZakres (0,0001 – 1,00) mg/l\nZakres (0,10 – 100) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) Normy M Woda E, Woda do spozycia przez ludzi E, Scieki E, Gleba E, Grunty E, Osady sciekowe E, Osady denne E, Mieszanki mineralno-asfaltowe: destrukt asfaltowy E Stezenie/zawartosc rteci\nZakres:\nZakres (0,0001 – 1,00) mg/l\nZakres (0,10 – 100) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) Normy M","categories":["water","environment"],"row_index":257,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of mercury","parameters_en":[{"name":"Range","range":"(0,0001 – 1,00) mg/l"},{"name":"Range","range":"(0,10 – 100) mg/kg"}],"search_en":"Concentration/content of mercury Cold vapour atomic absorption spectrometry (CVAAS) Range Range Normy M","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","parameters_zh":[{"name":"范围","range":"(0,0001 – 1,00) mg/l"},{"name":"范围","range":"(0,10 – 100) mg/kg"}],"search_zh":"汞的浓度/含量 冷蒸气原子吸收光谱法（CVAAS） 范围 范围 Normy M","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","methodology_zh":"汞的浓度/含量"},{"_id":"6a82c6ff884ede9a1b2c2a4e","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady (wyciągi wodne) O), E kod: 02 02, 03 01, 05 01, 07 02, 07 06, 11 01, 12 01, 17 01, 17 05, 19 01, 19 12","methodology":"Stężenie i zawartość formaldehydu (aldehydu mrówkowego)","parameters":[{"name":"Zakres","range":"(0,020 – 10) mg/l"},{"name":"Zakres","range":"(0,20 – 100) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie i zawartość formaldehydu (aldehydu mrówkowego)\nZakres:\nZakres (0,020 – 10) mg/l\nZakres (0,20 – 100) mg/kg\nMetoda spektrofotometryczna","reference":"Normy Procedury badawcze M","norm_bases":["Normy Procedury badawcze M"],"lab_section":null,"lab_address":null,"regulatory_area":"O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Odpady (wyciągi wodne) O), E kod: 02 02, 03 01, 05 01, 07 02, 07 06, 11 01, 12 01, 17 01, 17 05, 19 01, 19 12 Stężenie i zawartość formaldehydu (aldehydu mrówkowego)\nZakres:\nZakres (0,020 – 10) mg/l\nZakres (0,20 – 100) mg/kg\nMetoda spektrofotometryczna Normy Procedury badawcze M Odpady (wyciagi wodne) O), E kod: 02 02, 03 01, 05 01, 07 02, 07 06, 11 01, 12 01, 17 01, 17 05, 19 01, 19 12 Stezenie i zawartosc formaldehydu (aldehydu mrowkowego)\nZakres:\nZakres (0,020 – 10) mg/l\nZakres (0,20 – 100) mg/kg\nMetoda spektrofotometryczna Normy Procedury badawcze M","categories":["environment"],"row_index":258,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde (methanal) concentration and content","parameters_en":[{"name":"Range","range":"(0,020 – 10) mg/l"},{"name":"Range","range":"(0,20 – 100) mg/kg"}],"search_en":"Formaldehyde (methanal) concentration and content Spectrophotometric method Range Range Normy Procedury badawcze M","technique_en":"Spectrophotometric method","parameters_zh":[{"name":"范围","range":"(0,020 – 10) mg/l"},{"name":"范围","range":"(0,20 – 100) mg/kg"}],"search_zh":"分光光度法 范围 范围 Normy Procedury badawcze M","technique_zh":"分光光度法"},{"_id":"6a82c6ff884ede9a1b2c2a4f","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady (wyciągi wodne) O), E kod: 01 04, 10 01, 17 05, 19 05, 19 08,","methodology":"Stężenie i zawartość azotu ogólnego","parameters":[{"name":"Zakres","range":"(0,50 – 2000) mg/l"},{"name":"Zakres","range":"(5,0 – 20 000) mg/kg"}],"technique":"Metoda chemiluminescencyjna","techniques":["Metoda chemiluminescencyjna"],"computed":[],"activity":"Stężenie i zawartość azotu ogólnego\nZakres:\nZakres (0,50 – 2000) mg/l\nZakres (5,0 – 20 000) mg/kg\nMetoda chemiluminescencyjna","reference":"Normy Procedury badawcze M","norm_bases":["Normy Procedury badawcze M"],"lab_section":null,"lab_address":null,"regulatory_area":"O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Odpady (wyciągi wodne) O), E kod: 01 04, 10 01, 17 05, 19 05, 19 08, Stężenie i zawartość azotu ogólnego\nZakres:\nZakres (0,50 – 2000) mg/l\nZakres (5,0 – 20 000) mg/kg\nMetoda chemiluminescencyjna Normy Procedury badawcze M Odpady (wyciagi wodne) O), E kod: 01 04, 10 01, 17 05, 19 05, 19 08, Stezenie i zawartosc azotu ogolnego\nZakres:\nZakres (0,50 – 2000) mg/l\nZakres (5,0 – 20 000) mg/kg\nMetoda chemiluminescencyjna Normy Procedury badawcze M","categories":["environment"],"row_index":259,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration and content of total nitrogen","parameters_en":[{"name":"Range","range":"(0,50 – 2000) mg/l"},{"name":"Range","range":"(5,0 – 20 000) mg/kg"}],"search_en":"Concentration and content of total nitrogen Chemiluminescence method Range Range Normy Procedury badawcze M","technique_en":"Chemiluminescence method","parameters_zh":[{"name":"范围","range":"(0,50 – 2000) mg/l"},{"name":"范围","range":"(5,0 – 20 000) mg/kg"}],"search_zh":"化学发光法 范围 范围 Normy Procedury badawcze M","technique_zh":"化学发光法"},{"_id":"6a82c6ff884ede9a1b2c2a50","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady (wyciągi wodne) O), E kod: 01 04, 01 05, 10 01, 17 03, 19 05, 19 08, 19 12","methodology":"Stężenie i zawartość azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,20 – 100) mg/l"},{"name":"Zakres","range":"(2,0 – 1000) mg/kg"},{"name":"Stężenie i zawartość azotanów (z obliczeń)"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie i zawartość azotu azotanowego\nZakres:\nZakres (0,20 – 100) mg/l\nZakres (2,0 – 1000) mg/kg\nStężenie i zawartość azotanów (z obliczeń)\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"Normy Procedury badawcze M","norm_bases":["Normy Procedury badawcze M"],"lab_section":null,"lab_address":null,"regulatory_area":"O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Odpady (wyciągi wodne) O), E kod: 01 04, 01 05, 10 01, 17 03, 19 05, 19 08, 19 12 Stężenie i zawartość azotu azotanowego\nZakres:\nZakres (0,20 – 100) mg/l\nZakres (2,0 – 1000) mg/kg\nStężenie i zawartość azotanów (z obliczeń)\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną Normy Procedury badawcze M Odpady (wyciagi wodne) O), E kod: 01 04, 01 05, 10 01, 17 03, 19 05, 19 08, 19 12 Stezenie i zawartosc azotu azotanowego\nZakres:\nZakres (0,20 – 100) mg/l\nZakres (2,0 – 1000) mg/kg\nStezenie i zawartosc azotanow (z obliczen)\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna Normy Procedury badawcze M","categories":["environment"],"row_index":260,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration and content of nitrate nitrogen","parameters_en":[{"name":"Range","range":"(0,20 – 100) mg/l"},{"name":"Range","range":"(2,0 – 1000) mg/kg"},{"name":"Nitrate concentration and content (calculated)"}],"search_en":"Concentration and content of nitrate nitrogen Continuous flow analysis (CFA) with spectrophotometric detection Range Range Nitrate concentration and content (calculated) Normy Procedury badawcze M","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","parameters_zh":[{"name":"范围","range":"(0,20 – 100) mg/l"},{"name":"范围","range":"(2,0 – 1000) mg/kg"},{"name":"Stężenie i zawartość azotanów (z obliczeń)"}],"search_zh":"连续流动分析（CFA）分光光度检测法 范围 范围 Normy Procedury badawcze M","technique_zh":"连续流动分析（CFA）分光光度检测法"},{"_id":"6a82c6ff884ede9a1b2c2a51","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady (wyciągi wodne) O), E kod: 01 04, 01 05, 10 01, 19 05, 19 08, 19 12","methodology":"Stężenie i zawartość azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,020 – 4,0) mg/l"},{"name":"Zakres","range":"(0,20 – 40) mg/kg"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie i zawartość azotu azotynowego\nZakres:\nZakres (0,020 – 4,0) mg/l\nZakres (0,20 – 40) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"Normy Procedury badawcze M","norm_bases":["Normy Procedury badawcze M"],"lab_section":null,"lab_address":null,"regulatory_area":"O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Odpady (wyciągi wodne) O), E kod: 01 04, 01 05, 10 01, 19 05, 19 08, 19 12 Stężenie i zawartość azotu azotynowego\nZakres:\nZakres (0,020 – 4,0) mg/l\nZakres (0,20 – 40) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną Normy Procedury badawcze M Odpady (wyciagi wodne) O), E kod: 01 04, 01 05, 10 01, 19 05, 19 08, 19 12 Stezenie i zawartosc azotu azotynowego\nZakres:\nZakres (0,020 – 4,0) mg/l\nZakres (0,20 – 40) mg/kg\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna Normy Procedury badawcze M","categories":["environment"],"row_index":261,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration and content","parameters_en":[{"name":"Range","range":"(0,020 – 4,0) mg/l"},{"name":"Range","range":"(0,20 – 40) mg/kg"}],"search_en":"Nitrite nitrogen concentration and content Continuous flow analysis (CFA) with spectrophotometric detection Range Range Normy Procedury badawcze M","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","parameters_zh":[{"name":"范围","range":"(0,020 – 4,0) mg/l"},{"name":"范围","range":"(0,20 – 40) mg/kg"}],"search_zh":"亚硝酸盐氮的浓度与含量 连续流动分析（CFA）分光光度检测法 范围 范围 Normy Procedury badawcze M","technique_zh":"连续流动分析（CFA）分光光度检测法","methodology_zh":"亚硝酸盐氮的浓度与含量"},{"_id":"6a82c6ff884ede9a1b2c2a52","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady (wyciągi wodne) O), E kod: 01 01, 01 05, 10 01, 17 03, 19 05, 19 08, 19 12, 20 03","methodology":"Stężenie i zawartość cyjanków ogólnych","parameters":[{"name":"Zakres","range":"(0,010 – 0,10) mg/l"},{"name":"Zakres","range":"(0,10 – 1,0) mg/kg"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie i zawartość cyjanków ogólnych\nZakres:\nZakres (0,010 – 0,10) mg/l\nZakres (0,10 – 1,0) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"Normy Procedury badawcze M","norm_bases":["Normy Procedury badawcze M"],"lab_section":null,"lab_address":null,"regulatory_area":"O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Odpady (wyciągi wodne) O), E kod: 01 01, 01 05, 10 01, 17 03, 19 05, 19 08, 19 12, 20 03 Stężenie i zawartość cyjanków ogólnych\nZakres:\nZakres (0,010 – 0,10) mg/l\nZakres (0,10 – 1,0) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną Normy Procedury badawcze M Odpady (wyciagi wodne) O), E kod: 01 01, 01 05, 10 01, 17 03, 19 05, 19 08, 19 12, 20 03 Stezenie i zawartosc cyjankow ogolnych\nZakres:\nZakres (0,010 – 0,10) mg/l\nZakres (0,10 – 1,0) mg/kg\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna Normy Procedury badawcze M","categories":["environment"],"row_index":262,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total cyanide concentration and content","parameters_en":[{"name":"Range","range":"(0,010 – 0,10) mg/l"},{"name":"Range","range":"(0,10 – 1,0) mg/kg"}],"search_en":"Total cyanide concentration and content Continuous flow analysis (CFA) with spectrophotometric detection Range Range Normy Procedury badawcze M","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","parameters_zh":[{"name":"范围","range":"(0,010 – 0,10) mg/l"},{"name":"范围","range":"(0,10 – 1,0) mg/kg"}],"search_zh":"总氰化物的浓度与含量 连续流动分析（CFA）分光光度检测法 范围 范围 Normy Procedury badawcze M","technique_zh":"连续流动分析（CFA）分光光度检测法","methodology_zh":"总氰化物的浓度与含量"},{"_id":"6a82c6ff884ede9a1b2c2a53","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady (wyciągi wodne) E, O) kod: 01 01, 17 05,","methodology":"Stężenie i zawartość siarkowodoru i siarczków","parameters":[{"name":"Zakres","range":"(0,10 – 20) mg/l"},{"name":"Zakres","range":"(1,0 – 200) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie i zawartość siarkowodoru i siarczków\nZakres:\nZakres (0,10 – 20) mg/l\nZakres (1,0 – 200) mg/kg\nMetoda spektrofotometryczna","reference":"Procedury badawcze M","norm_bases":["Procedury badawcze M"],"lab_section":null,"lab_address":null,"regulatory_area":"O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Odpady (wyciągi wodne) E, O) kod: 01 01, 17 05, Stężenie i zawartość siarkowodoru i siarczków\nZakres:\nZakres (0,10 – 20) mg/l\nZakres (1,0 – 200) mg/kg\nMetoda spektrofotometryczna Procedury badawcze M Odpady (wyciagi wodne) E, O) kod: 01 01, 17 05, Stezenie i zawartosc siarkowodoru i siarczkow\nZakres:\nZakres (0,10 – 20) mg/l\nZakres (1,0 – 200) mg/kg\nMetoda spektrofotometryczna Procedury badawcze M","categories":["environment"],"row_index":263,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen sulphide and sulphide concentration and content","parameters_en":[{"name":"Range","range":"(0,10 – 20) mg/l"},{"name":"Range","range":"(1,0 – 200) mg/kg"}],"search_en":"Hydrogen sulphide and sulphide concentration and content Spectrophotometric method Range Range Procedury badawcze M","technique_en":"Spectrophotometric method","parameters_zh":[{"name":"范围","range":"(0,10 – 20) mg/l"},{"name":"范围","range":"(1,0 – 200) mg/kg"}],"search_zh":"分光光度法 范围 范围 Procedury badawcze M","technique_zh":"分光光度法"},{"_id":"6a82c6ff884ede9a1b2c2a54","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady (wyciągi wodne) O), E kod: 01 01, 10 01, 17 03, 19 05, 19 08, 19 09, 19 12, 20 03","methodology":"Chemiczne zapotrzebowanie tlenu (ChZT-Cr)","parameters":[{"name":"Zakres","range":"(15 – 1500) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu (ChZT-Cr)\nZakres (15 – 1500) mg/l O2\nMetoda spektrofotometryczna","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Odpady (wyciągi wodne) O), E kod: 01 01, 10 01, 17 03, 19 05, 19 08, 19 09, 19 12, 20 03 Chemiczne zapotrzebowanie tlenu (ChZT-Cr)\nZakres (15 – 1500) mg/l O2\nMetoda spektrofotometryczna Normy M Odpady (wyciagi wodne) O), E kod: 01 01, 10 01, 17 03, 19 05, 19 08, 19 09, 19 12, 20 03 Chemiczne zapotrzebowanie tlenu (ChZT-Cr)\nZakres (15 – 1500) mg/l O2\nMetoda spektrofotometryczna Normy M","categories":["environment"],"row_index":264,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand (COD-Cr)","parameters_en":[{"name":"Range","range":"(15 – 1500) mg/l O2"}],"search_en":"Chemical oxygen demand (COD-Cr) Spectrophotometric method Range Normy M","technique_en":"Spectrophotometric method","methodology_zh":"化学需氧量（ChZT-Cr / CODCr）","parameters_zh":[{"name":"范围","range":"(15 – 1500) mg/l O2"}],"search_zh":"化学需氧量（ChZT-Cr / CODCr） 分光光度法 范围 Normy M","technique_zh":"分光光度法"},{"_id":"6a82c6ff884ede9a1b2c2a55","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady (wyciągi wodne) O), E kod: 01 01, 10 01, 11 01, 12 01, 17 01, 19 08, 19 12, 20 02","methodology":"Stężenie i zawartość chromu(VI)","parameters":[{"name":"Zakres","range":"(0,010 – 5,0) mg/l"},{"name":"Zakres","range":"(0,10 – 50) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie i zawartość chromu(VI)\nZakres:\nZakres (0,010 – 5,0) mg/l\nZakres (0,10 – 50) mg/kg\nMetoda spektrofotometryczna","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Odpady (wyciągi wodne) O), E kod: 01 01, 10 01, 11 01, 12 01, 17 01, 19 08, 19 12, 20 02 Stężenie i zawartość chromu(VI)\nZakres:\nZakres (0,010 – 5,0) mg/l\nZakres (0,10 – 50) mg/kg\nMetoda spektrofotometryczna Normy M Odpady (wyciagi wodne) O), E kod: 01 01, 10 01, 11 01, 12 01, 17 01, 19 08, 19 12, 20 02 Stezenie i zawartosc chromu(VI)\nZakres:\nZakres (0,010 – 5,0) mg/l\nZakres (0,10 – 50) mg/kg\nMetoda spektrofotometryczna Normy M","categories":["environment"],"row_index":265,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium(VI) concentration and content","parameters_en":[{"name":"Range","range":"(0,010 – 5,0) mg/l"},{"name":"Range","range":"(0,10 – 50) mg/kg"}],"search_en":"Chromium(VI) concentration and content Spectrophotometric method Range Range Normy M","technique_en":"Spectrophotometric method","parameters_zh":[{"name":"范围","range":"(0,010 – 5,0) mg/l"},{"name":"范围","range":"(0,10 – 50) mg/kg"}],"search_zh":"分光光度法 范围 范围 Normy M","technique_zh":"分光光度法"},{"_id":"6a82c6ff884ede9a1b2c2a56","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady, E kod: 01 04, 07 02, 10 01, 12 01, 19 01, 19 02, 19 08","methodology":"Zawartość cyjanków wolnych, ogólnych","parameters":[{"name":"Zakres","range":"(1,0 – 100) mg/kg"},{"name":"Zawartość cyjanków związanych (z obliczeń)"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Zawartość cyjanków wolnych, ogólnych\nZakres:\nZakres (1,0 – 100) mg/kg\nZawartość cyjanków związanych (z obliczeń)\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Odpady, E kod: 01 04, 07 02, 10 01, 12 01, 19 01, 19 02, 19 08 Zawartość cyjanków wolnych, ogólnych\nZakres:\nZakres (1,0 – 100) mg/kg\nZawartość cyjanków związanych (z obliczeń)\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną Normy M Odpady, E kod: 01 04, 07 02, 10 01, 12 01, 19 01, 19 02, 19 08 Zawartosc cyjankow wolnych, ogolnych\nZakres:\nZakres (1,0 – 100) mg/kg\nZawartosc cyjankow zwiazanych (z obliczen)\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna Normy M","categories":["environment"],"row_index":266,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free and total cyanide content","parameters_en":[{"name":"Range","range":"(1,0 – 100) mg/kg"},{"name":"Combined cyanide content (calculated)"}],"search_en":"Free and total cyanide content Continuous flow analysis (CFA) with spectrophotometric detection Range Combined cyanide content (calculated) Normy M","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","parameters_zh":[{"name":"范围","range":"(1,0 – 100) mg/kg"},{"name":"络合氰化物含量（由计算得出）"}],"search_zh":"连续流动分析（CFA）分光光度检测法 范围 络合氰化物含量（由计算得出） Normy M","technique_zh":"连续流动分析（CFA）分光光度检测法"},{"_id":"6a82c6ff884ede9a1b2c2a57","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady, E kod: 02 02, 02 03","methodology":"pH","parameters":[{"name":"Zakres","range":"(2,0 – 12,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (2,0 – 12,0)\nMetoda potencjometryczna","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Odpady, E kod: 02 02, 02 03 pH\nZakres (2,0 – 12,0)\nMetoda potencjometryczna Normy M Odpady, E kod: 02 02, 02 03 pH\nZakres (2,0 – 12,0)\nMetoda potencjometryczna Normy M","categories":["environment"],"row_index":267,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"(2,0 – 12,0)"}],"search_en":"pH Potentiometric method Range Normy M","technique_en":"Potentiometric method","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(2,0 – 12,0)"}],"search_zh":"pH 值 电位法 范围 Normy M","technique_zh":"电位法"},{"_id":"6a82c6ff884ede9a1b2c2a58","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady, E kod: 02 01, 02 02, 02 03, 02 04, 02 05, 19 05, 19 08, 19 12, 20 02, 20 03","methodology":"Zawartość azotu amonowego","parameters":[],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu amonowego\nMetoda miareczkowa","reference":"Procedury badawcze M","norm_bases":["Procedury badawcze M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Odpady, E kod: 02 01, 02 02, 02 03, 02 04, 02 05, 19 05, 19 08, 19 12, 20 02, 20 03 Zawartość azotu amonowego\nMetoda miareczkowa Procedury badawcze M Odpady, E kod: 02 01, 02 02, 02 03, 02 04, 02 05, 19 05, 19 08, 19 12, 20 02, 20 03 Zawartosc azotu amonowego\nMetoda miareczkowa Procedury badawcze M","categories":["environment"],"row_index":268,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen content","search_en":"Ammonium nitrogen content Titrimetric method Procedury badawcze M","technique_en":"Titrimetric method","search_zh":"氨氮含量 滴定法 Procedury badawcze M","technique_zh":"滴定法","methodology_zh":"氨氮含量"},{"_id":"6a82c6ff884ede9a1b2c2a59","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Paliwa stałe E: stałe paliwa wtórne (SRF), surowce do produkcji paliw z odpadów, Odpady, E kod: 02 04, 19 08, 19 12","methodology":"Zawartość azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,10 – 9,00)%"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu Kjeldahla\nZakres (0,10 – 9,00)%\nMetoda miareczkowa","reference":"Procedury badawcze M","norm_bases":["Procedury badawcze M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Paliwa stałe E: stałe paliwa wtórne (SRF), surowce do produkcji paliw z odpadów, Odpady, E kod: 02 04, 19 08, 19 12 Zawartość azotu Kjeldahla\nZakres (0,10 – 9,00)%\nMetoda miareczkowa Procedury badawcze M Paliwa stale E: stale paliwa wtorne (SRF), surowce do produkcji paliw z odpadow, Odpady, E kod: 02 04, 19 08, 19 12 Zawartosc azotu Kjeldahla\nZakres (0,10 – 9,00)%\nMetoda miareczkowa Procedury badawcze M","categories":["environment","petro"],"row_index":269,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen content","parameters_en":[{"name":"Range","range":"(0,10 – 9,00)%"}],"search_en":"Kjeldahl nitrogen content Titrimetric method Range Procedury badawcze M","technique_en":"Titrimetric method","parameters_zh":[{"name":"范围","range":"(0,10 – 9,00)%"}],"search_zh":"凯氏氮含量 滴定法 范围 Procedury badawcze M","technique_zh":"滴定法","methodology_zh":"凯氏氮含量"},{"_id":"6a82c6ff884ede9a1b2c2a5a","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Paliwa stałe E: stałe paliwa wtórne (SRF), surowce do produkcji paliw z odpadów, odpady do termicznego przekształcania zgodnie z rozporządzeniem, Ministra Środowiska Dz. U. 2016, poz. 847, Odpady, E kod: 02 04, 03 01, 05 01, 07 01, 07 02, 15 01, 16 01, 17 02, 17 05, 19 05, 19 08, 19 12, 20 01, 20 02, 20 03","methodology":"Całkowita zawartość chloru","parameters":[{"name":"Zakres","range":"(0,010 – 6,5)%"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Całkowita zawartość chloru\nZakres (0,010 – 6,5)%\nMetoda spektrofotometryczna","reference":"Normy Procedury badawcze M","norm_bases":["Normy Procedury badawcze M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Paliwa stałe E: stałe paliwa wtórne (SRF), surowce do produkcji paliw z odpadów, odpady do termicznego przekształcania zgodnie z rozporządzeniem, Ministra Środowiska Dz. U. 2016, poz. 847, Odpady, E kod: 02 04, 03 01, 05 01, 07 01, 07 02, 15 01, 16 01, 17 02, 17 05, 19 05, 19 08, 19 12, 20 01, 20 02, 20 03 Całkowita zawartość chloru\nZakres (0,010 – 6,5)%\nMetoda spektrofotometryczna Normy Procedury badawcze M Paliwa stale E: stale paliwa wtorne (SRF), surowce do produkcji paliw z odpadow, odpady do termicznego przeksztalcania zgodnie z rozporzadzeniem, Ministra Srodowiska Dz. U. 2016, poz. 847, Odpady, E kod: 02 04, 03 01, 05 01, 07 01, 07 02, 15 01, 16 01, 17 02, 17 05, 19 05, 19 08, 19 12, 20 01, 20 02, 20 03 Calkowita zawartosc chloru\nZakres (0,010 – 6,5)%\nMetoda spektrofotometryczna Normy Procedury badawcze M","categories":["environment","petro"],"row_index":270,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total chlorine content","parameters_en":[{"name":"Range","range":"(0,010 – 6,5)%"}],"search_en":"Total chlorine content Spectrophotometric method Range Normy Procedury badawcze M","technique_en":"Spectrophotometric method","parameters_zh":[{"name":"范围","range":"(0,010 – 6,5)%"}],"search_zh":"分光光度法 范围 Normy Procedury badawcze M","technique_zh":"分光光度法"},{"_id":"6a82c6ff884ede9a1b2c2a5b","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady, E kod: 01 01, 01 04, 03 01, 05 01, 07 06, 17 01, 17 02, 17 03, 17 05, 19 03, 19 08, 19 12","methodology":"Zawartość fenolu","parameters":[{"name":"Zakres","range":"(0,050 – 100) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość fenolu\nZakres (0,050 – 100) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"Procedury badawcze M","norm_bases":["Procedury badawcze M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Odpady, E kod: 01 01, 01 04, 03 01, 05 01, 07 06, 17 01, 17 02, 17 03, 17 05, 19 03, 19 08, 19 12 Zawartość fenolu\nZakres (0,050 – 100) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) Procedury badawcze M Odpady, E kod: 01 01, 01 04, 03 01, 05 01, 07 06, 17 01, 17 02, 17 03, 17 05, 19 03, 19 08, 19 12 Zawartosc fenolu\nZakres (0,050 – 100) mg/kg\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) Procedury badawcze M","categories":["environment"],"row_index":271,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol content","parameters_en":[{"name":"Range","range":"(0,050 – 100) mg/kg"}],"search_en":"Phenol content Gas chromatography with mass spectrometry detection (GC-MS) Range Procedury badawcze M","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","parameters_zh":[{"name":"范围","range":"(0,050 – 100) mg/kg"}],"search_zh":"苯酚含量 气相色谱-质谱法（GC-MS） 范围 Procedury badawcze M","technique_zh":"气相色谱-质谱法（GC-MS）","methodology_zh":"苯酚含量"},{"_id":"6a82c6ff884ede9a1b2c2a5c","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady, E kod: 01 01, 01 04, 03 01, 05 01, 07 06, 17 01, 17 02, 17 03, 17 05, 19 03, 19 08, 19 12","methodology":"Zawartość krezoli","parameters":[{"name":"2-metylofenol (o-krezol)"},{"name":"Zakres","range":"(0,050 - 20) mg/kg"},{"name":"3-metylofenol (m-krezol)","range":"(0,050 - 20) mg/kg"},{"name":"4-metylofenol (p-krezol)","range":"(0,050 - 20) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość krezoli\nZakres:\n2-metylofenol (o-krezol)\nZakres (0,050 - 20) mg/kg\n3-metylofenol (m-krezol) (0,050 - 20) mg/kg\n4-metylofenol (p-krezol) (0,050 - 20) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"Procedury badawcze M","norm_bases":["Procedury badawcze M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Odpady, E kod: 01 01, 01 04, 03 01, 05 01, 07 06, 17 01, 17 02, 17 03, 17 05, 19 03, 19 08, 19 12 Zawartość krezoli\nZakres:\n2-metylofenol (o-krezol)\nZakres (0,050 - 20) mg/kg\n3-metylofenol (m-krezol) (0,050 - 20) mg/kg\n4-metylofenol (p-krezol) (0,050 - 20) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) Procedury badawcze M Odpady, E kod: 01 01, 01 04, 03 01, 05 01, 07 06, 17 01, 17 02, 17 03, 17 05, 19 03, 19 08, 19 12 Zawartosc krezoli\nZakres:\n2-metylofenol (o-krezol)\nZakres (0,050 - 20) mg/kg\n3-metylofenol (m-krezol) (0,050 - 20) mg/kg\n4-metylofenol (p-krezol) (0,050 - 20) mg/kg\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) Procedury badawcze M","categories":["environment"],"row_index":272,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cresol content","parameters_en":[{"name":"2-methylphenol (o-cresol)"},{"name":"Range","range":"(0,050 - 20) mg/kg"},{"name":"3-methylphenol (m-cresol)","range":"(0,050 - 20) mg/kg"},{"name":"4-methylphenol (p-cresol)","range":"(0,050 - 20) mg/kg"}],"search_en":"Cresol content Gas chromatography with mass spectrometry detection (GC-MS) 2-methylphenol (o-cresol) Range 3-methylphenol (m-cresol) 4-methylphenol (p-cresol) Procedury badawcze M","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","parameters_zh":[{"name":"2-甲基苯酚（邻甲酚）"},{"name":"范围","range":"(0,050 - 20) mg/kg"},{"name":"3-甲基苯酚（间甲酚）","range":"(0,050 - 20) mg/kg"},{"name":"4-甲基苯酚（对甲酚）","range":"(0,050 - 20) mg/kg"}],"search_zh":"甲酚含量 气相色谱-质谱法（GC-MS） 2-甲基苯酚（邻甲酚） 范围 3-甲基苯酚（间甲酚） 4-甲基苯酚（对甲酚） Procedury badawcze M","technique_zh":"气相色谱-质谱法（GC-MS）","methodology_zh":"甲酚含量"},{"_id":"6a82c6ff884ede9a1b2c2a5d","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Mieszanki mineralno- asfaltowe: destrukt asfaltowy E,","methodology":"Stężenie pierwiastków:","parameters":[{"name":"arsen"},{"name":"selen"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Stężenie pierwiastków:\nZakres:\narsen\nselen\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Mieszanki mineralno- asfaltowe: destrukt asfaltowy E, Stężenie pierwiastków:\nZakres:\narsen\nselen\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) Normy M Mieszanki mineralno- asfaltowe: destrukt asfaltowy E, Stezenie pierwiastkow:\nZakres:\narsen\nselen\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) Normy M","categories":["other"],"row_index":273,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentrations:","parameters_en":[{"name":"arsenic"},{"name":"selenium"}],"search_en":"Element concentrations: Inductively coupled plasma mass spectrometry (ICP-MS) arsenic selenium Normy M","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","methodology_zh":"元素浓度：","search_zh":"元素浓度： 电感耦合等离子体质谱法（ICP-MS） 砷 硒 Normy M","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","parameters_zh":[{"name":"砷"},{"name":"硒"}]},{"_id":"6a82c6ff884ede9a1b2c2a5e","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Mieszanki mineralno- asfaltowe: destrukt asfaltowy E,","methodology":"Stężenie i zawartość azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,20 – 100) mg/l"},{"name":"Zakres","range":"(2,0 – 1000) mg/kg"},{"name":"Stężenie i zawartość azotanów (z obliczeń)"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie i zawartość azotu azotanowego\nZakres:\nZakres (0,20 – 100) mg/l\nZakres (2,0 – 1000) mg/kg\nStężenie i zawartość azotanów (z obliczeń)\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"Normy Procedury badawcze M","norm_bases":["Normy Procedury badawcze M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Mieszanki mineralno- asfaltowe: destrukt asfaltowy E, Stężenie i zawartość azotu azotanowego\nZakres:\nZakres (0,20 – 100) mg/l\nZakres (2,0 – 1000) mg/kg\nStężenie i zawartość azotanów (z obliczeń)\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną Normy Procedury badawcze M Mieszanki mineralno- asfaltowe: destrukt asfaltowy E, Stezenie i zawartosc azotu azotanowego\nZakres:\nZakres (0,20 – 100) mg/l\nZakres (2,0 – 1000) mg/kg\nStezenie i zawartosc azotanow (z obliczen)\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna Normy Procedury badawcze M","categories":["other"],"row_index":274,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration and content of nitrate nitrogen","parameters_en":[{"name":"Range","range":"(0,20 – 100) mg/l"},{"name":"Range","range":"(2,0 – 1000) mg/kg"},{"name":"Nitrate concentration and content (calculated)"}],"search_en":"Concentration and content of nitrate nitrogen Continuous flow analysis (CFA) with spectrophotometric detection Range Range Nitrate concentration and content (calculated) Normy Procedury badawcze M","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","parameters_zh":[{"name":"范围","range":"(0,20 – 100) mg/l"},{"name":"范围","range":"(2,0 – 1000) mg/kg"},{"name":"Stężenie i zawartość azotanów (z obliczeń)"}],"search_zh":"连续流动分析（CFA）分光光度检测法 范围 范围 Normy Procedury badawcze M","technique_zh":"连续流动分析（CFA）分光光度检测法"},{"_id":"6a82c6ff884ede9a1b2c2a5f","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Mieszanki mineralno- asfaltowe: destrukt asfaltowy E,","methodology":"Stężenie i zawartość cyjanków ogólnych","parameters":[{"name":"Zakres","range":"(0,010 – 0,10) mg/l"},{"name":"Zakres","range":"(0,10 – 1,0) mg/kg"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie i zawartość cyjanków ogólnych\nZakres:\nZakres (0,010 – 0,10) mg/l\nZakres (0,10 – 1,0) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"Normy Procedury badawcze M","norm_bases":["Normy Procedury badawcze M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Mieszanki mineralno- asfaltowe: destrukt asfaltowy E, Stężenie i zawartość cyjanków ogólnych\nZakres:\nZakres (0,010 – 0,10) mg/l\nZakres (0,10 – 1,0) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną Normy Procedury badawcze M Mieszanki mineralno- asfaltowe: destrukt asfaltowy E, Stezenie i zawartosc cyjankow ogolnych\nZakres:\nZakres (0,010 – 0,10) mg/l\nZakres (0,10 – 1,0) mg/kg\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna Normy Procedury badawcze M","categories":["other"],"row_index":275,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total cyanide concentration and content","parameters_en":[{"name":"Range","range":"(0,010 – 0,10) mg/l"},{"name":"Range","range":"(0,10 – 1,0) mg/kg"}],"search_en":"Total cyanide concentration and content Continuous flow analysis (CFA) with spectrophotometric detection Range Range Normy Procedury badawcze M","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","parameters_zh":[{"name":"范围","range":"(0,010 – 0,10) mg/l"},{"name":"范围","range":"(0,10 – 1,0) mg/kg"}],"search_zh":"总氰化物的浓度与含量 连续流动分析（CFA）分光光度检测法 范围 范围 Normy Procedury badawcze M","technique_zh":"连续流动分析（CFA）分光光度检测法","methodology_zh":"总氰化物的浓度与含量"},{"_id":"6a82c6ff884ede9a1b2c2a60","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Mieszanki mineralno- asfaltowe: destrukt asfaltowy E,","methodology":"Chemiczne zapotrzebowanie tlenu (ChZT-Cr)","parameters":[{"name":"Zakres","range":"(15 – 1500) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu (ChZT-Cr)\nZakres (15 – 1500) mg/l O2\nMetoda spektrofotometryczna","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Mieszanki mineralno- asfaltowe: destrukt asfaltowy E, Chemiczne zapotrzebowanie tlenu (ChZT-Cr)\nZakres (15 – 1500) mg/l O2\nMetoda spektrofotometryczna Normy M Mieszanki mineralno- asfaltowe: destrukt asfaltowy E, Chemiczne zapotrzebowanie tlenu (ChZT-Cr)\nZakres (15 – 1500) mg/l O2\nMetoda spektrofotometryczna Normy M","categories":["other"],"row_index":276,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand (COD-Cr)","parameters_en":[{"name":"Range","range":"(15 – 1500) mg/l O2"}],"search_en":"Chemical oxygen demand (COD-Cr) Spectrophotometric method Range Normy M","technique_en":"Spectrophotometric method","methodology_zh":"化学需氧量（ChZT-Cr / CODCr）","parameters_zh":[{"name":"范围","range":"(15 – 1500) mg/l O2"}],"search_zh":"化学需氧量（ChZT-Cr / CODCr） 分光光度法 范围 Normy M","technique_zh":"分光光度法"},{"_id":"6a82c6ff884ede9a1b2c2a61","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Mieszanki mineralno- asfaltowe: destrukt asfaltowy E,","methodology":"Stężenie i zawartość chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 50 000) mg/l"},{"name":"Zakres","range":"(50 – 500 000) mg/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie i zawartość chlorków\nZakres:\nZakres (5,0 – 50 000) mg/l\nZakres (50 – 500 000) mg/kg\nMetoda miareczkowa","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Mieszanki mineralno- asfaltowe: destrukt asfaltowy E, Stężenie i zawartość chlorków\nZakres:\nZakres (5,0 – 50 000) mg/l\nZakres (50 – 500 000) mg/kg\nMetoda miareczkowa Normy M Mieszanki mineralno- asfaltowe: destrukt asfaltowy E, Stezenie i zawartosc chlorkow\nZakres:\nZakres (5,0 – 50 000) mg/l\nZakres (50 – 500 000) mg/kg\nMetoda miareczkowa Normy M","categories":["other"],"row_index":277,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration and content","parameters_en":[{"name":"Range","range":"(5,0 – 50 000) mg/l"},{"name":"Range","range":"(50 – 500 000) mg/kg"}],"search_en":"Chloride concentration and content Titrimetric method Range Range Normy M","technique_en":"Titrimetric method","parameters_zh":[{"name":"范围","range":"(5,0 – 50 000) mg/l"},{"name":"范围","range":"(50 – 500 000) mg/kg"}],"search_zh":"氯化物的浓度与含量 滴定法 范围 范围 Normy M","technique_zh":"滴定法","methodology_zh":"氯化物的浓度与含量"},{"_id":"6a82c6ff884ede9a1b2c2a62","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Mieszanki mineralno- asfaltowe: destrukt asfaltowy E,","methodology":"Stężenie i zawartość fluorków","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/l"},{"name":"Zakres","range":"(1,0 – 1000) mg/kg"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Stężenie i zawartość fluorków\nZakres:\nZakres (0,10 – 100) mg/l\nZakres (1,0 – 1000) mg/kg\nMetoda potencjometryczna","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Mieszanki mineralno- asfaltowe: destrukt asfaltowy E, Stężenie i zawartość fluorków\nZakres:\nZakres (0,10 – 100) mg/l\nZakres (1,0 – 1000) mg/kg\nMetoda potencjometryczna Normy M Mieszanki mineralno- asfaltowe: destrukt asfaltowy E, Stezenie i zawartosc fluorkow\nZakres:\nZakres (0,10 – 100) mg/l\nZakres (1,0 – 1000) mg/kg\nMetoda potencjometryczna Normy M","categories":["other"],"row_index":278,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fluoride concentration and content","parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/l"},{"name":"Range","range":"(1,0 – 1000) mg/kg"}],"search_en":"Fluoride concentration and content Potentiometric method Range Range Normy M","technique_en":"Potentiometric method","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/l"},{"name":"范围","range":"(1,0 – 1000) mg/kg"}],"search_zh":"氟化物的浓度与含量 电位法 范围 范围 Normy M","technique_zh":"电位法","methodology_zh":"氟化物的浓度与含量"},{"_id":"6a82c6ff884ede9a1b2c2a63","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Mieszanki mineralno- asfaltowe: destrukt asfaltowy E,","methodology":"Stężenie i zawartość siarczanów","parameters":[{"name":"Zakres","range":"(10 - 5000) mg/l"},{"name":"Zakres","range":"(100 - 50 000) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie i zawartość siarczanów\nZakres:\nZakres (10 - 5000) mg/l\nZakres (100 - 50 000) mg/kg\nMetoda wagowa","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Mieszanki mineralno- asfaltowe: destrukt asfaltowy E, Stężenie i zawartość siarczanów\nZakres:\nZakres (10 - 5000) mg/l\nZakres (100 - 50 000) mg/kg\nMetoda wagowa Normy M Mieszanki mineralno- asfaltowe: destrukt asfaltowy E, Stezenie i zawartosc siarczanow\nZakres:\nZakres (10 - 5000) mg/l\nZakres (100 - 50 000) mg/kg\nMetoda wagowa Normy M","categories":["other"],"row_index":279,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration and content","parameters_en":[{"name":"Range","range":"(10 - 5000) mg/l"},{"name":"Range","range":"(100 - 50 000) mg/kg"}],"search_en":"Sulfate concentration and content Gravimetric method Range Range Normy M","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(10 - 5000) mg/l"},{"name":"范围","range":"(100 - 50 000) mg/kg"}],"search_zh":"硫酸盐的浓度与含量 重量法 范围 范围 Normy M","technique_zh":"重量法","methodology_zh":"硫酸盐的浓度与含量"},{"_id":"6a82c6ff884ede9a1b2c2a64","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Mieszanki mineralno- asfaltowe: destrukt asfaltowy E,","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"acenaften"},{"name":"acenaftylen"},{"name":"antracen"},{"name":"benzo(a)antracen"},{"name":"benzo(a)piren"},{"name":"benzo(b)fluoranten"},{"name":"benzo(k)fluoranten"},{"name":"benzo(ghi)perylen"},{"name":"chryzen"},{"name":"dibenzo(a,h)antracen"},{"name":"fenantren"},{"name":"fluoranten"},{"name":"fluoren"},{"name":"indeno","range":"(1,2,3-cd)piren"},{"name":"naftalen"},{"name":"piren Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nacenaften\nacenaftylen\nantracen\nbenzo(a)antracen\nbenzo(a)piren\nbenzo(b)fluoranten\nbenzo(k)fluoranten\nbenzo(ghi)perylen\nchryzen\ndibenzo(a,h)antracen\nfenantren\nfluoranten\nfluoren\nindeno (1,2,3-cd)piren\nnaftalen\npiren Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Mieszanki mineralno- asfaltowe: destrukt asfaltowy E, Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nacenaften\nacenaftylen\nantracen\nbenzo(a)antracen\nbenzo(a)piren\nbenzo(b)fluoranten\nbenzo(k)fluoranten\nbenzo(ghi)perylen\nchryzen\ndibenzo(a,h)antracen\nfenantren\nfluoranten\nfluoren\nindeno (1,2,3-cd)piren\nnaftalen\npiren Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) Normy M Mieszanki mineralno- asfaltowe: destrukt asfaltowy E, Zawartosc wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nacenaften\nacenaftylen\nantracen\nbenzo(a)antracen\nbenzo(a)piren\nbenzo(b)fluoranten\nbenzo(k)fluoranten\nbenzo(ghi)perylen\nchryzen\ndibenzo(a,h)antracen\nfenantren\nfluoranten\nfluoren\nindeno (1,2,3-cd)piren\nnaftalen\npiren Suma wielopierscieniowych weglowodorow aromatycznych (WWA) (z obliczen)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) Normy M","categories":["other"],"row_index":280,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polycyclic aromatic hydrocarbons (PAH) content","parameters_en":[{"name":"acenaphthene"},{"name":"acenaphthylene"},{"name":"anthracene"},{"name":"benzo(a)anthracene"},{"name":"benzo(a)pyrene"},{"name":"benzo(b)fluoranthene"},{"name":"benzo(k)fluoranthene"},{"name":"benzo(ghi)perylene"},{"name":"chrysene"},{"name":"dibenzo(a,h)anthracene"},{"name":"phenanthrene"},{"name":"fluoranthene"},{"name":"fluorene"},{"name":"indeno","range":"(1,2,3-cd)piren"},{"name":"naphthalene"},{"name":"pyrene Sum of polycyclic aromatic hydrocarbons (PAH) (calculated)"}],"search_en":"Polycyclic aromatic hydrocarbons (PAH) content Gas chromatography with mass spectrometry detection (GC-MS) acenaphthene acenaphthylene anthracene benzo(a)anthracene benzo(a)pyrene benzo(b)fluoranthene benzo(k)fluoranthene benzo(ghi)perylene chrysene dibenzo(a,h)anthracene phenanthrene fluoranthene fluorene indeno naphthalene pyrene Sum of polycyclic aromatic hydrocarbons (PAH) (calculated) Normy M","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","search_zh":"多环芳烃（PAHs）含量 气相色谱-质谱法（GC-MS） 苊 苊烯 蒽 苯并（a）蒽 苯并（a）芘 苯并（b）荧蒽 苯并（k）荧蒽 苯并（ghi）苝 䓛 二苯并（a,h）蒽 菲 荧蒽 芴 茚 萘 Normy M","technique_zh":"气相色谱-质谱法（GC-MS）","parameters_zh":[{"name":"苊"},{"name":"苊烯"},{"name":"蒽"},{"name":"苯并（a）蒽"},{"name":"苯并（a）芘"},{"name":"苯并（b）荧蒽"},{"name":"苯并（k）荧蒽"},{"name":"苯并（ghi）苝"},{"name":"䓛"},{"name":"二苯并（a,h）蒽"},{"name":"菲"},{"name":"荧蒽"},{"name":"芴"},{"name":"茚","range":"(1,2,3-cd)piren"},{"name":"萘"},{"name":"piren Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)"}],"methodology_zh":"多环芳烃（PAHs）含量"},{"_id":"6a82c6ff884ede9a1b2c2a65","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady (wyciągi wodne) DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII), Odpady, E (wyciągi wodne) kod: 02 07 99, 04 01 99, 10 01 99, 10 02 99, 12 01 18*, 16 01 22, 16 02 16, 16 07 99, 16 80 01, 16 81 01*, 16 81 02, 16 82 02","methodology":"Stężenie i zawartość chlorków A, C, D, F, H","parameters":[{"name":"Zakres","range":"(5,0 – 50 000) mg/l"},{"name":"Zakres","range":"(50 – 500 000) mg/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie i zawartość chlorków A, C, D, F, H\nZakres:\nZakres (5,0 – 50 000) mg/l\nZakres (50 – 500 000) mg/kg\nMetoda miareczkowa","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: A. Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) B. Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. 2015, poz. 257) C. Rozporządzeniem Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. 2015, poz. 132) D. Rozporządzeniem Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. 2015, poz. 796) E. Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz. U. 2023, poz. 56) F. Rozporządzeniem Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. 2011 nr 175, poz. 1048) G. Rozporządzeniem Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. 2016, poz. 847) H. Rozporządzenie Ministra Klimatu i Środowiska z dnia 23 grudnia 2021 r. w sprawie określenia szczegółowych warunków utraty statusu odpadów dla odpadów destruktu asfaltowego (Dz. U. 2021, poz. 2468) I. Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz.U. 2017, poz. 2490) J. Rozporządzenie Ministra Rozwoju z dnia 21 stycznia 2016 r. w sprawie wymagań dotyczących prowadzenia procesu termicznego przekształcania odpadów oraz sposobów postępowania z odpadami powstałymi w wyniku tego procesu (Dz. U. 2016, poz. 108) DAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Odpady (wyciągi wodne) DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII), Odpady, E (wyciągi wodne) kod: 02 07 99, 04 01 99, 10 01 99, 10 02 99, 12 01 18*, 16 01 22, 16 02 16, 16 07 99, 16 80 01, 16 81 01*, 16 81 02, 16 82 02 Stężenie i zawartość chlorków A, C, D, F, H\nZakres:\nZakres (5,0 – 50 000) mg/l\nZakres (50 – 500 000) mg/kg\nMetoda miareczkowa Normy M Odpady (wyciagi wodne) DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV), Szlamy i odpady plynne (V), Odpady z przetwarzania odpadow (VI), Osady z procesow przemyslowych (VII), Osady sciekowe (IX), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skory i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII), Odpady, E (wyciagi wodne) kod: 02 07 99, 04 01 99, 10 01 99, 10 02 99, 12 01 18*, 16 01 22, 16 02 16, 16 07 99, 16 80 01, 16 81 01*, 16 81 02, 16 82 02 Stezenie i zawartosc chlorkow A, C, D, F, H\nZakres:\nZakres (5,0 – 50 000) mg/l\nZakres (50 – 500 000) mg/kg\nMetoda miareczkowa Normy M","categories":["water","environment","food","materials","construction"],"row_index":281,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration and content A, C, D, F, H","parameters_en":[{"name":"Range","range":"(5,0 – 50 000) mg/l"},{"name":"Range","range":"(50 – 500 000) mg/kg"}],"search_en":"Chloride concentration and content A, C, D, F, H Titrimetric method Range Range Normy M","technique_en":"Titrimetric method","parameters_zh":[{"name":"范围","range":"(5,0 – 50 000) mg/l"},{"name":"范围","range":"(50 – 500 000) mg/kg"}],"search_zh":"滴定法 范围 范围 Normy M","technique_zh":"滴定法"},{"_id":"6a82c6ff884ede9a1b2c2a66","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady (wyciągi wodne) DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII), Odpady, E (wyciągi wodne) kod: 02 07 99, 04 01 99, 10 01 99, 10 02 99, 12 01 18*, 16 01 22, 16 02 16, 16 07 99, 16 80 01, 16 81 01*, 16 81 02, 16 82 02","methodology":"Stężenie i zawartość fluorków A, C, D, F, H","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/l"},{"name":"Zakres","range":"(1,0 – 1000) mg/kg"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Stężenie i zawartość fluorków A, C, D, F, H\nZakres:\nZakres (0,10 – 100) mg/l\nZakres (1,0 – 1000) mg/kg\nMetoda potencjometryczna","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: A. Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) B. Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. 2015, poz. 257) C. Rozporządzeniem Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. 2015, poz. 132) D. Rozporządzeniem Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. 2015, poz. 796) E. Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz. U. 2023, poz. 56) F. Rozporządzeniem Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. 2011 nr 175, poz. 1048) G. Rozporządzeniem Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. 2016, poz. 847) H. Rozporządzenie Ministra Klimatu i Środowiska z dnia 23 grudnia 2021 r. w sprawie określenia szczegółowych warunków utraty statusu odpadów dla odpadów destruktu asfaltowego (Dz. U. 2021, poz. 2468) I. Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz.U. 2017, poz. 2490) J. Rozporządzenie Ministra Rozwoju z dnia 21 stycznia 2016 r. w sprawie wymagań dotyczących prowadzenia procesu termicznego przekształcania odpadów oraz sposobów postępowania z odpadami powstałymi w wyniku tego procesu (Dz. U. 2016, poz. 108) DAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Odpady (wyciągi wodne) DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII), Odpady, E (wyciągi wodne) kod: 02 07 99, 04 01 99, 10 01 99, 10 02 99, 12 01 18*, 16 01 22, 16 02 16, 16 07 99, 16 80 01, 16 81 01*, 16 81 02, 16 82 02 Stężenie i zawartość fluorków A, C, D, F, H\nZakres:\nZakres (0,10 – 100) mg/l\nZakres (1,0 – 1000) mg/kg\nMetoda potencjometryczna Normy M Odpady (wyciagi wodne) DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV), Szlamy i odpady plynne (V), Odpady z przetwarzania odpadow (VI), Osady z procesow przemyslowych (VII), Osady sciekowe (IX), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skory i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII), Odpady, E (wyciagi wodne) kod: 02 07 99, 04 01 99, 10 01 99, 10 02 99, 12 01 18*, 16 01 22, 16 02 16, 16 07 99, 16 80 01, 16 81 01*, 16 81 02, 16 82 02 Stezenie i zawartosc fluorkow A, C, D, F, H\nZakres:\nZakres (0,10 – 100) mg/l\nZakres (1,0 – 1000) mg/kg\nMetoda potencjometryczna Normy M","categories":["water","environment","food","materials","construction"],"row_index":282,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fluoride concentration and content A, C, D, F, H","parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/l"},{"name":"Range","range":"(1,0 – 1000) mg/kg"}],"search_en":"Fluoride concentration and content A, C, D, F, H Potentiometric method Range Range Normy M","technique_en":"Potentiometric method","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/l"},{"name":"范围","range":"(1,0 – 1000) mg/kg"}],"search_zh":"电位法 范围 范围 Normy M","technique_zh":"电位法"},{"_id":"6a82c6ff884ede9a1b2c2a67","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady (wyciągi wodne) DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII), Odpady, E (wyciągi wodne) kod: 02 07 99, 04 01 99, 10 01 99, 10 02 99, 12 01 18*, 16 01 22, 16 02 16, 16 07 99, 16 80 01, 16 81 01*, 16 81 02, 16 82 02","methodology":"Stężenie i zawartość siarczanów A, C, D, F, H","parameters":[{"name":"Zakres","range":"(10 - 5000) mg/l"},{"name":"Zakres","range":"(100 - 50 000) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie i zawartość siarczanów A, C, D, F, H\nZakres:\nZakres (10 - 5000) mg/l\nZakres (100 - 50 000) mg/kg\nMetoda wagowa","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: A. Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) B. Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. 2015, poz. 257) C. Rozporządzeniem Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. 2015, poz. 132) D. Rozporządzeniem Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. 2015, poz. 796) E. Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz. U. 2023, poz. 56) F. Rozporządzeniem Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. 2011 nr 175, poz. 1048) G. Rozporządzeniem Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. 2016, poz. 847) H. Rozporządzenie Ministra Klimatu i Środowiska z dnia 23 grudnia 2021 r. w sprawie określenia szczegółowych warunków utraty statusu odpadów dla odpadów destruktu asfaltowego (Dz. U. 2021, poz. 2468) I. Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz.U. 2017, poz. 2490) J. Rozporządzenie Ministra Rozwoju z dnia 21 stycznia 2016 r. w sprawie wymagań dotyczących prowadzenia procesu termicznego przekształcania odpadów oraz sposobów postępowania z odpadami powstałymi w wyniku tego procesu (Dz. U. 2016, poz. 108) DAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Odpady (wyciągi wodne) DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII), Odpady, E (wyciągi wodne) kod: 02 07 99, 04 01 99, 10 01 99, 10 02 99, 12 01 18*, 16 01 22, 16 02 16, 16 07 99, 16 80 01, 16 81 01*, 16 81 02, 16 82 02 Stężenie i zawartość siarczanów A, C, D, F, H\nZakres:\nZakres (10 - 5000) mg/l\nZakres (100 - 50 000) mg/kg\nMetoda wagowa Normy M Odpady (wyciagi wodne) DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV), Szlamy i odpady plynne (V), Odpady z przetwarzania odpadow (VI), Osady z procesow przemyslowych (VII), Osady sciekowe (IX), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skory i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII), Odpady, E (wyciagi wodne) kod: 02 07 99, 04 01 99, 10 01 99, 10 02 99, 12 01 18*, 16 01 22, 16 02 16, 16 07 99, 16 80 01, 16 81 01*, 16 81 02, 16 82 02 Stezenie i zawartosc siarczanow A, C, D, F, H\nZakres:\nZakres (10 - 5000) mg/l\nZakres (100 - 50 000) mg/kg\nMetoda wagowa Normy M","categories":["water","environment","food","materials","construction"],"row_index":283,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulphate concentration and content A, C, D, F, H","parameters_en":[{"name":"Range","range":"(10 - 5000) mg/l"},{"name":"Range","range":"(100 - 50 000) mg/kg"}],"search_en":"Sulphate concentration and content A, C, D, F, H Gravimetric method Range Range Normy M","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(10 - 5000) mg/l"},{"name":"范围","range":"(100 - 50 000) mg/kg"}],"search_zh":"重量法 范围 范围 Normy M","technique_zh":"重量法"},{"_id":"6a82c6ff884ede9a1b2c2a68","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady (wyciągi wodne) DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII), Odpady, E (wyciągi wodne) kod: 02 07 99, 04 01 99, 10 01 99, 10 02 99, 12 01 18*, 16 01 22, 16 02 16, 16 07 99, 16 80 01, 16 81 01*, 16 81 02, 16 82 02","methodology":"Wskaźnik fenolowy (indeks fenolowy) A, C, D, F","parameters":[{"name":"Zakres","range":"(0,0050 – 2,5) mg/l"},{"name":"Zakres","range":"(0,050 – 25) mg/kg"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Wskaźnik fenolowy (indeks fenolowy) A, C, D, F\nZakres:\nZakres (0,0050 – 2,5) mg/l\nZakres (0,050 – 25) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: A. Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) B. Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. 2015, poz. 257) C. Rozporządzeniem Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. 2015, poz. 132) D. Rozporządzeniem Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. 2015, poz. 796) E. Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz. U. 2023, poz. 56) F. Rozporządzeniem Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. 2011 nr 175, poz. 1048) G. Rozporządzeniem Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. 2016, poz. 847) H. Rozporządzenie Ministra Klimatu i Środowiska z dnia 23 grudnia 2021 r. w sprawie określenia szczegółowych warunków utraty statusu odpadów dla odpadów destruktu asfaltowego (Dz. U. 2021, poz. 2468) I. Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz.U. 2017, poz. 2490) J. Rozporządzenie Ministra Rozwoju z dnia 21 stycznia 2016 r. w sprawie wymagań dotyczących prowadzenia procesu termicznego przekształcania odpadów oraz sposobów postępowania z odpadami powstałymi w wyniku tego procesu (Dz. U. 2016, poz. 108) DAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Odpady (wyciągi wodne) DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII), Odpady, E (wyciągi wodne) kod: 02 07 99, 04 01 99, 10 01 99, 10 02 99, 12 01 18*, 16 01 22, 16 02 16, 16 07 99, 16 80 01, 16 81 01*, 16 81 02, 16 82 02 Wskaźnik fenolowy (indeks fenolowy) A, C, D, F\nZakres:\nZakres (0,0050 – 2,5) mg/l\nZakres (0,050 – 25) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną Normy M Odpady (wyciagi wodne) DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV), Szlamy i odpady plynne (V), Odpady z przetwarzania odpadow (VI), Osady z procesow przemyslowych (VII), Osady sciekowe (IX), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skory i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII), Odpady, E (wyciagi wodne) kod: 02 07 99, 04 01 99, 10 01 99, 10 02 99, 12 01 18*, 16 01 22, 16 02 16, 16 07 99, 16 80 01, 16 81 01*, 16 81 02, 16 82 02 Wskaznik fenolowy (indeks fenolowy) A, C, D, F\nZakres:\nZakres (0,0050 – 2,5) mg/l\nZakres (0,050 – 25) mg/kg\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna Normy M","categories":["water","environment","food","materials","construction"],"row_index":284,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol index (phenol index) A, C, D, F","parameters_en":[{"name":"Range","range":"(0,0050 – 2,5) mg/l"},{"name":"Range","range":"(0,050 – 25) mg/kg"}],"search_en":"Phenol index (phenol index) A, C, D, F Continuous flow analysis (CFA) with spectrophotometric detection Range Range Normy M","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","parameters_zh":[{"name":"范围","range":"(0,0050 – 2,5) mg/l"},{"name":"范围","range":"(0,050 – 25) mg/kg"}],"search_zh":"连续流动分析（CFA）分光光度检测法 范围 范围 Normy M","technique_zh":"连续流动分析（CFA）分光光度检测法"},{"_id":"6a82c6ff884ede9a1b2c2a69","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady (wyciągi wodne) DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII), Odpady, E (wyciągi wodne) kod: 02 07 99, 04 01 99, 10 01 99, 10 02 99, 12 01 18*, 16 01 22, 16 02 16, 16 07 99, 16 80 01, 16 81 01*, 16 81 02, 16 82 02","methodology":"Stężenie i zawartość rozpuszczonego węgla organicznego (DOC) A, C, D, F","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"},{"name":"Zakres","range":"(20 – 10 000) mg/kg"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Stężenie i zawartość rozpuszczonego węgla organicznego (DOC) A, C, D, F\nZakres:\nZakres (2,0 – 1000) mg/l\nZakres (20 – 10 000) mg/kg\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: A. Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) B. Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. 2015, poz. 257) C. Rozporządzeniem Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. 2015, poz. 132) D. Rozporządzeniem Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. 2015, poz. 796) E. Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz. U. 2023, poz. 56) F. Rozporządzeniem Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. 2011 nr 175, poz. 1048) G. Rozporządzeniem Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. 2016, poz. 847) H. Rozporządzenie Ministra Klimatu i Środowiska z dnia 23 grudnia 2021 r. w sprawie określenia szczegółowych warunków utraty statusu odpadów dla odpadów destruktu asfaltowego (Dz. U. 2021, poz. 2468) I. Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz.U. 2017, poz. 2490) J. Rozporządzenie Ministra Rozwoju z dnia 21 stycznia 2016 r. w sprawie wymagań dotyczących prowadzenia procesu termicznego przekształcania odpadów oraz sposobów postępowania z odpadami powstałymi w wyniku tego procesu (Dz. U. 2016, poz. 108) DAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Odpady (wyciągi wodne) DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII), Odpady, E (wyciągi wodne) kod: 02 07 99, 04 01 99, 10 01 99, 10 02 99, 12 01 18*, 16 01 22, 16 02 16, 16 07 99, 16 80 01, 16 81 01*, 16 81 02, 16 82 02 Stężenie i zawartość rozpuszczonego węgla organicznego (DOC) A, C, D, F\nZakres:\nZakres (2,0 – 1000) mg/l\nZakres (20 – 10 000) mg/kg\nMetoda wysokotemperaturowego spalania z detekcją IR Normy M Odpady (wyciagi wodne) DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV), Szlamy i odpady plynne (V), Odpady z przetwarzania odpadow (VI), Osady z procesow przemyslowych (VII), Osady sciekowe (IX), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skory i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII), Odpady, E (wyciagi wodne) kod: 02 07 99, 04 01 99, 10 01 99, 10 02 99, 12 01 18*, 16 01 22, 16 02 16, 16 07 99, 16 80 01, 16 81 01*, 16 81 02, 16 82 02 Stezenie i zawartosc rozpuszczonego wegla organicznego (DOC) A, C, D, F\nZakres:\nZakres (2,0 – 1000) mg/l\nZakres (20 – 10 000) mg/kg\nMetoda wysokotemperaturowego spalania z detekcja IR Normy M","categories":["water","environment","food","materials","construction"],"row_index":285,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved organic carbon (DOC) concentration and content A, C, D, F","parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"},{"name":"Range","range":"(20 – 10 000) mg/kg"}],"search_en":"Dissolved organic carbon (DOC) concentration and content A, C, D, F High-temperature combustion with IR detection Range Range Normy M","technique_en":"High-temperature combustion with IR detection","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"},{"name":"范围","range":"(20 – 10 000) mg/kg"}],"search_zh":"高温燃烧红外检测法 范围 范围 Normy M","technique_zh":"高温燃烧红外检测法"},{"_id":"6a82c6ff884ede9a1b2c2a6a","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady (wyciągi wodne) DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII), Odpady, E (wyciągi wodne) kod: 02 07 99, 04 01 99, 10 01 99, 10 02 99, 12 01 18*, 16 01 22, 16 02 16, 16 07 99, 16 80 01, 16 81 01*, 16 81 02, 16 82 02","methodology":"Stężenie i zawartość stałych związków rozpuszczonych (TDS) A, C, D, F","parameters":[{"name":"Zakres","range":"(10 – 50 000) mg/l"},{"name":"Zakres","range":"(100 – 500 000) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie i zawartość stałych związków rozpuszczonych (TDS) A, C, D, F\nZakres:\nZakres (10 – 50 000) mg/l\nZakres (100 – 500 000) mg/kg\nMetoda wagowa","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: A. Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) B. Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. 2015, poz. 257) C. Rozporządzeniem Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. 2015, poz. 132) D. Rozporządzeniem Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. 2015, poz. 796) E. Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz. U. 2023, poz. 56) F. Rozporządzeniem Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. 2011 nr 175, poz. 1048) G. Rozporządzeniem Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. 2016, poz. 847) H. Rozporządzenie Ministra Klimatu i Środowiska z dnia 23 grudnia 2021 r. w sprawie określenia szczegółowych warunków utraty statusu odpadów dla odpadów destruktu asfaltowego (Dz. U. 2021, poz. 2468) I. Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz.U. 2017, poz. 2490) J. Rozporządzenie Ministra Rozwoju z dnia 21 stycznia 2016 r. w sprawie wymagań dotyczących prowadzenia procesu termicznego przekształcania odpadów oraz sposobów postępowania z odpadami powstałymi w wyniku tego procesu (Dz. U. 2016, poz. 108) DAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Odpady (wyciągi wodne) DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII), Odpady, E (wyciągi wodne) kod: 02 07 99, 04 01 99, 10 01 99, 10 02 99, 12 01 18*, 16 01 22, 16 02 16, 16 07 99, 16 80 01, 16 81 01*, 16 81 02, 16 82 02 Stężenie i zawartość stałych związków rozpuszczonych (TDS) A, C, D, F\nZakres:\nZakres (10 – 50 000) mg/l\nZakres (100 – 500 000) mg/kg\nMetoda wagowa Normy M Odpady (wyciagi wodne) DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV), Szlamy i odpady plynne (V), Odpady z przetwarzania odpadow (VI), Osady z procesow przemyslowych (VII), Osady sciekowe (IX), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skory i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII), Odpady, E (wyciagi wodne) kod: 02 07 99, 04 01 99, 10 01 99, 10 02 99, 12 01 18*, 16 01 22, 16 02 16, 16 07 99, 16 80 01, 16 81 01*, 16 81 02, 16 82 02 Stezenie i zawartosc stalych zwiazkow rozpuszczonych (TDS) A, C, D, F\nZakres:\nZakres (10 – 50 000) mg/l\nZakres (100 – 500 000) mg/kg\nMetoda wagowa Normy M","categories":["water","environment","food","materials","construction"],"row_index":286,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total dissolved solids (TDS) concentration and content A, C, D, F","parameters_en":[{"name":"Range","range":"(10 – 50 000) mg/l"},{"name":"Range","range":"(100 – 500 000) mg/kg"}],"search_en":"Total dissolved solids (TDS) concentration and content A, C, D, F Gravimetric method Range Range Normy M","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(10 – 50 000) mg/l"},{"name":"范围","range":"(100 – 500 000) mg/kg"}],"search_zh":"重量法 范围 范围 Normy M","technique_zh":"重量法"},{"_id":"6a82c6ff884ede9a1b2c2a6b","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady (wyciągi wodne) DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII), Odpady, E (wyciągi wodne) kod: 02 07 99, 04 01 99, 10 01 99, 10 02 99, 12 01 18*, 16 01 22, 16 02 16, 16 07 99, 16 80 01, 16 81 01*, 16 81 02, 16 82 02","methodology":"pH A, C","parameters":[{"name":"Zakres","range":"(2,0 – 12,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH A, C\nZakres (2,0 – 12,0)\nMetoda potencjometryczna","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: A. Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) B. Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. 2015, poz. 257) C. Rozporządzeniem Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. 2015, poz. 132) D. Rozporządzeniem Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. 2015, poz. 796) E. Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz. U. 2023, poz. 56) F. Rozporządzeniem Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. 2011 nr 175, poz. 1048) G. Rozporządzeniem Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. 2016, poz. 847) H. Rozporządzenie Ministra Klimatu i Środowiska z dnia 23 grudnia 2021 r. w sprawie określenia szczegółowych warunków utraty statusu odpadów dla odpadów destruktu asfaltowego (Dz. U. 2021, poz. 2468) I. Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz.U. 2017, poz. 2490) J. Rozporządzenie Ministra Rozwoju z dnia 21 stycznia 2016 r. w sprawie wymagań dotyczących prowadzenia procesu termicznego przekształcania odpadów oraz sposobów postępowania z odpadami powstałymi w wyniku tego procesu (Dz. U. 2016, poz. 108) DAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Odpady (wyciągi wodne) DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII), Odpady, E (wyciągi wodne) kod: 02 07 99, 04 01 99, 10 01 99, 10 02 99, 12 01 18*, 16 01 22, 16 02 16, 16 07 99, 16 80 01, 16 81 01*, 16 81 02, 16 82 02 pH A, C\nZakres (2,0 – 12,0)\nMetoda potencjometryczna Normy M Odpady (wyciagi wodne) DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV), Szlamy i odpady plynne (V), Odpady z przetwarzania odpadow (VI), Osady z procesow przemyslowych (VII), Osady sciekowe (IX), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skory i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII), Odpady, E (wyciagi wodne) kod: 02 07 99, 04 01 99, 10 01 99, 10 02 99, 12 01 18*, 16 01 22, 16 02 16, 16 07 99, 16 80 01, 16 81 01*, 16 81 02, 16 82 02 pH A, C\nZakres (2,0 – 12,0)\nMetoda potencjometryczna Normy M","categories":["water","environment","food","materials","construction"],"row_index":287,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH A, C","parameters_en":[{"name":"Range","range":"(2,0 – 12,0)"}],"search_en":"pH A, C Potentiometric method Range Normy M","technique_en":"Potentiometric method","parameters_zh":[{"name":"范围","range":"(2,0 – 12,0)"}],"search_zh":"电位法 范围 Normy M","technique_zh":"电位法"},{"_id":"6a82c6ff884ede9a1b2c2a6c","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady (wyciągi wodne) DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII), Odpady, E (wyciągi wodne) kod: 02 07 99, 04 01 99, 10 01 99, 10 02 99, 12 01 18*, 16 01 22, 16 02 16, 16 07 99, 16 80 01, 16 81 01*, 16 81 02, 16 82 02","methodology":"Zdolność do neutralizacji kwasów (ANC) A","parameters":[{"name":"Zakres","range":"(100 – 50 000) mg/kg CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zdolność do neutralizacji kwasów (ANC) A\nZakres (100 – 50 000) mg/kg CaCO3\nMetoda miareczkowa","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: A. Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) B. Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. 2015, poz. 257) C. Rozporządzeniem Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. 2015, poz. 132) D. Rozporządzeniem Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. 2015, poz. 796) E. Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz. U. 2023, poz. 56) F. Rozporządzeniem Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. 2011 nr 175, poz. 1048) G. Rozporządzeniem Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. 2016, poz. 847) H. Rozporządzenie Ministra Klimatu i Środowiska z dnia 23 grudnia 2021 r. w sprawie określenia szczegółowych warunków utraty statusu odpadów dla odpadów destruktu asfaltowego (Dz. U. 2021, poz. 2468) I. Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz.U. 2017, poz. 2490) J. Rozporządzenie Ministra Rozwoju z dnia 21 stycznia 2016 r. w sprawie wymagań dotyczących prowadzenia procesu termicznego przekształcania odpadów oraz sposobów postępowania z odpadami powstałymi w wyniku tego procesu (Dz. U. 2016, poz. 108) DAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Odpady (wyciągi wodne) DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII), Odpady, E (wyciągi wodne) kod: 02 07 99, 04 01 99, 10 01 99, 10 02 99, 12 01 18*, 16 01 22, 16 02 16, 16 07 99, 16 80 01, 16 81 01*, 16 81 02, 16 82 02 Zdolność do neutralizacji kwasów (ANC) A\nZakres (100 – 50 000) mg/kg CaCO3\nMetoda miareczkowa Normy M Odpady (wyciagi wodne) DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV), Szlamy i odpady plynne (V), Odpady z przetwarzania odpadow (VI), Osady z procesow przemyslowych (VII), Osady sciekowe (IX), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skory i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII), Odpady, E (wyciagi wodne) kod: 02 07 99, 04 01 99, 10 01 99, 10 02 99, 12 01 18*, 16 01 22, 16 02 16, 16 07 99, 16 80 01, 16 81 01*, 16 81 02, 16 82 02 Zdolnosc do neutralizacji kwasow (ANC) A\nZakres (100 – 50 000) mg/kg CaCO3\nMetoda miareczkowa Normy M","categories":["water","environment","food","materials","construction"],"row_index":288,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acid neutralization capacity (ANC) A","parameters_en":[{"name":"Range","range":"(100 – 50 000) mg/kg CaCO3"}],"search_en":"Acid neutralization capacity (ANC) A Titrimetric method Range Normy M","technique_en":"Titrimetric method","parameters_zh":[{"name":"范围","range":"(100 – 50 000) mg/kg CaCO3"}],"search_zh":"滴定法 范围 Normy M","technique_zh":"滴定法"},{"_id":"6a82c6ff884ede9a1b2c2a6d","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady zawierające związki ropopochodne (VIII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII), Odpady E, O) kod: 02 07 99, 10 02 99, 12 01 18*, 12 01 99, 16 07 99","methodology":"Całkowita zawartość węgla (TC) A, C, D, E, F, G, I, J","parameters":[{"name":"Zakres","range":"(0,50 – 47) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Całkowita zawartość węgla (TC) A, C, D, E, F, G, I, J\nZakres (0,50 – 47) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: A. Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) B. Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. 2015, poz. 257) C. Rozporządzeniem Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. 2015, poz. 132) D. Rozporządzeniem Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. 2015, poz. 796) E. Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz. U. 2023, poz. 56) F. Rozporządzeniem Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. 2011 nr 175, poz. 1048) G. Rozporządzeniem Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. 2016, poz. 847) H. Rozporządzenie Ministra Klimatu i Środowiska z dnia 23 grudnia 2021 r. w sprawie określenia szczegółowych warunków utraty statusu odpadów dla odpadów destruktu asfaltowego (Dz. U. 2021, poz. 2468) I. Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz.U. 2017, poz. 2490) J. Rozporządzenie Ministra Rozwoju z dnia 21 stycznia 2016 r. w sprawie wymagań dotyczących prowadzenia procesu termicznego przekształcania odpadów oraz sposobów postępowania z odpadami powstałymi w wyniku tego procesu (Dz. U. 2016, poz. 108) O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. DAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady zawierające związki ropopochodne (VIII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII), Odpady E, O) kod: 02 07 99, 10 02 99, 12 01 18*, 12 01 99, 16 07 99 Całkowita zawartość węgla (TC) A, C, D, E, F, G, I, J\nZakres (0,50 – 47) %\nMetoda wysokotemperaturowego spalania z detekcją IR Normy M Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Szlamy i odpady plynne (V), Odpady z przetwarzania odpadow (VI), Osady z procesow przemyslowych (VII), Osady zawierajace zwiazki ropopochodne (VIII), Osady sciekowe (IX), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skory i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII), Odpady E, O) kod: 02 07 99, 10 02 99, 12 01 18*, 12 01 99, 16 07 99 Calkowita zawartosc wegla (TC) A, C, D, E, F, G, I, J\nZakres (0,50 – 47) %\nMetoda wysokotemperaturowego spalania z detekcja IR Normy M","categories":["water","environment","materials","construction"],"row_index":289,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content (TC) A, C, D, E, F, G, I, J","parameters_en":[{"name":"Range","range":"(0,50 – 47) %"}],"search_en":"Total carbon content (TC) A, C, D, E, F, G, I, J High-temperature combustion with IR detection Range Normy M","technique_en":"High-temperature combustion with IR detection","parameters_zh":[{"name":"范围","range":"(0,50 – 47) %"}],"search_zh":"高温燃烧红外检测法 范围 Normy M","technique_zh":"高温燃烧红外检测法"},{"_id":"6a82c6ff884ede9a1b2c2a6e","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady zawierające związki ropopochodne (VIII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII), Odpady E, O) kod: 02 07 99, 10 02 99, 12 01 18*, 12 01 99, 16 07 99","methodology":"Zawartość węgla nieorganicznego (TIC) A, C, D, E, F, G, I, J","parameters":[{"name":"Zakres","range":"(0,50 – 12) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla nieorganicznego (TIC) A, C, D, E, F, G, I, J\nZakres (0,50 – 12) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: A. Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) B. Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. 2015, poz. 257) C. Rozporządzeniem Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. 2015, poz. 132) D. Rozporządzeniem Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. 2015, poz. 796) E. Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz. U. 2023, poz. 56) F. Rozporządzeniem Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. 2011 nr 175, poz. 1048) G. Rozporządzeniem Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. 2016, poz. 847) H. Rozporządzenie Ministra Klimatu i Środowiska z dnia 23 grudnia 2021 r. w sprawie określenia szczegółowych warunków utraty statusu odpadów dla odpadów destruktu asfaltowego (Dz. U. 2021, poz. 2468) I. Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz.U. 2017, poz. 2490) J. Rozporządzenie Ministra Rozwoju z dnia 21 stycznia 2016 r. w sprawie wymagań dotyczących prowadzenia procesu termicznego przekształcania odpadów oraz sposobów postępowania z odpadami powstałymi w wyniku tego procesu (Dz. U. 2016, poz. 108) O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. DAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady zawierające związki ropopochodne (VIII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII), Odpady E, O) kod: 02 07 99, 10 02 99, 12 01 18*, 12 01 99, 16 07 99 Zawartość węgla nieorganicznego (TIC) A, C, D, E, F, G, I, J\nZakres (0,50 – 12) %\nMetoda wysokotemperaturowego spalania z detekcją IR Normy M Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Szlamy i odpady plynne (V), Odpady z przetwarzania odpadow (VI), Osady z procesow przemyslowych (VII), Osady zawierajace zwiazki ropopochodne (VIII), Osady sciekowe (IX), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skory i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII), Odpady E, O) kod: 02 07 99, 10 02 99, 12 01 18*, 12 01 99, 16 07 99 Zawartosc wegla nieorganicznego (TIC) A, C, D, E, F, G, I, J\nZakres (0,50 – 12) %\nMetoda wysokotemperaturowego spalania z detekcja IR Normy M","categories":["water","environment","materials","construction"],"row_index":290,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of inorganic carbon (TIC) A, C, D, E, F, G, I, J","parameters_en":[{"name":"Range","range":"(0,50 – 12) %"}],"search_en":"Content of inorganic carbon (TIC) A, C, D, E, F, G, I, J High-temperature combustion with IR detection Range Normy M","technique_en":"High-temperature combustion with IR detection","parameters_zh":[{"name":"范围","range":"(0,50 – 12) %"}],"search_zh":"高温燃烧红外检测法 范围 Normy M","technique_zh":"高温燃烧红外检测法"},{"_id":"6a82c6ff884ede9a1b2c2a6f","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady zawierające związki ropopochodne (VIII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII), Odpady E, O) kod: 02 07 99, 10 02 99, 12 01 18*, 12 01 99, 16 07 99","methodology":"Zawartość ogólnego węgla organicznego (TOC), A, C, D, E, F, G, I, J (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość ogólnego węgla organicznego (TOC), A, C, D, E, F, G, I, J (z obliczeń)","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: A. Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) B. Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. 2015, poz. 257) C. Rozporządzeniem Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. 2015, poz. 132) D. Rozporządzeniem Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. 2015, poz. 796) E. Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz. U. 2023, poz. 56) F. Rozporządzeniem Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. 2011 nr 175, poz. 1048) G. Rozporządzeniem Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. 2016, poz. 847) H. Rozporządzenie Ministra Klimatu i Środowiska z dnia 23 grudnia 2021 r. w sprawie określenia szczegółowych warunków utraty statusu odpadów dla odpadów destruktu asfaltowego (Dz. U. 2021, poz. 2468) I. Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz.U. 2017, poz. 2490) J. Rozporządzenie Ministra Rozwoju z dnia 21 stycznia 2016 r. w sprawie wymagań dotyczących prowadzenia procesu termicznego przekształcania odpadów oraz sposobów postępowania z odpadami powstałymi w wyniku tego procesu (Dz. U. 2016, poz. 108) O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. DAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady zawierające związki ropopochodne (VIII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII), Odpady E, O) kod: 02 07 99, 10 02 99, 12 01 18*, 12 01 99, 16 07 99 Zawartość ogólnego węgla organicznego (TOC), A, C, D, E, F, G, I, J (z obliczeń) Normy M Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Szlamy i odpady plynne (V), Odpady z przetwarzania odpadow (VI), Osady z procesow przemyslowych (VII), Osady zawierajace zwiazki ropopochodne (VIII), Osady sciekowe (IX), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skory i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII), Odpady E, O) kod: 02 07 99, 10 02 99, 12 01 18*, 12 01 99, 16 07 99 Zawartosc ogolnego wegla organicznego (TOC), A, C, D, E, F, G, I, J (z obliczen) Normy M","categories":["water","environment","materials","construction"],"row_index":291,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon content (TOC), A, C, D, E, F, G, I, J (calculated)","search_en":"Total organic carbon content (TOC), A, C, D, E, F, G, I, J (calculated) Normy M"},{"_id":"6a82c6ff884ede9a1b2c2a70","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady DAB-11, E: Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","methodology":"Aktywność oddechowa (AT4) E, I","parameters":[{"name":"Zakres","range":"(1,0 – 30) mg O2/g"}],"technique":"Metoda manometryczna","techniques":["Metoda manometryczna"],"computed":[],"activity":"Aktywność oddechowa (AT4) E, I\nZakres (1,0 – 30) mg O2/g\nMetoda manometryczna","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: A. Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) B. Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. 2015, poz. 257) C. Rozporządzeniem Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. 2015, poz. 132) D. Rozporządzeniem Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. 2015, poz. 796) E. Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz. U. 2023, poz. 56) F. Rozporządzeniem Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. 2011 nr 175, poz. 1048) G. Rozporządzeniem Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. 2016, poz. 847) H. Rozporządzenie Ministra Klimatu i Środowiska z dnia 23 grudnia 2021 r. w sprawie określenia szczegółowych warunków utraty statusu odpadów dla odpadów destruktu asfaltowego (Dz. U. 2021, poz. 2468) I. Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz.U. 2017, poz. 2490) J. Rozporządzenie Ministra Rozwoju z dnia 21 stycznia 2016 r. w sprawie wymagań dotyczących prowadzenia procesu termicznego przekształcania odpadów oraz sposobów postępowania z odpadami powstałymi w wyniku tego procesu (Dz. U. 2016, poz. 108) DAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Odpady DAB-11, E: Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Aktywność oddechowa (AT4) E, I\nZakres (1,0 – 30) mg O2/g\nMetoda manometryczna Normy M Odpady DAB-11, E: Szlamy i odpady plynne (V), Odpady z przetwarzania odpadow (VI), Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Aktywnosc oddechowa (AT4) E, I\nZakres (1,0 – 30) mg O2/g\nMetoda manometryczna Normy M","categories":["environment","water","metrology"],"row_index":292,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Respiration activity (AT4) E, I","parameters_en":[{"name":"Range","range":"(1,0 – 30) mg O2/g"}],"search_en":"Respiration activity (AT4) E, I Manometric method Range Normy M","technique_en":"Manometric method","parameters_zh":[{"name":"范围","range":"(1,0 – 30) mg O2/g"}],"search_zh":"压力计法 范围 Normy M","technique_zh":"压力计法"},{"_id":"6a82c6ff884ede9a1b2c2a71","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady zawierające związki ropopochodne (VIII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne nieorganiczne - kwasy, zasady, sole (XIII), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady metali żelaznych i nieżelaznych (XX), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII), Odpady, E kod: 10 01 99, 16 81 01*, 16 81 02","methodology":"Zawartość suchej masy/zawartość wody/wilgoć całkowita A, B, C, D, E, G, H, I, J","parameters":[{"name":"Zakres","range":"(1,0 – 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość suchej masy/zawartość wody/wilgoć całkowita A, B, C, D, E, G, H, I, J\nZakres (1,0 – 99,5) %\nMetoda wagowa","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: A. Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) B. Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. 2015, poz. 257) C. Rozporządzeniem Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. 2015, poz. 132) D. Rozporządzeniem Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. 2015, poz. 796) E. Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz. U. 2023, poz. 56) F. Rozporządzeniem Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. 2011 nr 175, poz. 1048) G. Rozporządzeniem Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. 2016, poz. 847) H. Rozporządzenie Ministra Klimatu i Środowiska z dnia 23 grudnia 2021 r. w sprawie określenia szczegółowych warunków utraty statusu odpadów dla odpadów destruktu asfaltowego (Dz. U. 2021, poz. 2468) I. Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz.U. 2017, poz. 2490) J. Rozporządzenie Ministra Rozwoju z dnia 21 stycznia 2016 r. w sprawie wymagań dotyczących prowadzenia procesu termicznego przekształcania odpadów oraz sposobów postępowania z odpadami powstałymi w wyniku tego procesu (Dz. U. 2016, poz. 108) DAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady zawierające związki ropopochodne (VIII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne nieorganiczne - kwasy, zasady, sole (XIII), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady metali żelaznych i nieżelaznych (XX), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII), Odpady, E kod: 10 01 99, 16 81 01*, 16 81 02 Zawartość suchej masy/zawartość wody/wilgoć całkowita A, B, C, D, E, G, H, I, J\nZakres (1,0 – 99,5) %\nMetoda wagowa Normy M Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV), Szlamy i odpady plynne (V), Odpady z przetwarzania odpadow (VI), Osady z procesow przemyslowych (VII), Osady zawierajace zwiazki ropopochodne (VIII), Osady sciekowe (IX), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne nieorganiczne - kwasy, zasady, sole (XIII), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), Odpady metali zelaznych i niezelaznych (XX), Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skory i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII), Odpady, E kod: 10 01 99, 16 81 01*, 16 81 02 Zawartosc suchej masy/zawartosc wody/wilgoc calkowita A, B, C, D, E, G, H, I, J\nZakres (1,0 – 99,5) %\nMetoda wagowa Normy M","categories":["water","materials","environment","food","construction"],"row_index":293,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter content/water content/total moisture A, B, C, D, E, G, H, I, J","parameters_en":[{"name":"Range","range":"(1,0 – 99,5) %"}],"search_en":"Dry matter content/water content/total moisture A, B, C, D, E, G, H, I, J Gravimetric method Range Normy M","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(1,0 – 99,5) %"}],"search_zh":"重量法 范围 Normy M","technique_zh":"重量法"},{"_id":"6a82c6ff884ede9a1b2c2a72","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady zawierające związki ropopochodne (VIII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne nieorganiczne - kwasy, zasady, sole (XIII), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII), Odpady, E kod: 10 01 99, 16 81 01*, 16 81 02","methodology":"Straty przy prażeniu suchej masy (LOI) / zawartość substancji organicznych A, B, C, D, E, G, I, J","parameters":[{"name":"Zakres","range":"(1,0 – 99,5)%"},{"name":"Pozostałość po prażeniu / substancje mineralne (z obliczeń)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy (LOI) / zawartość substancji organicznych A, B, C, D, E, G, I, J\nZakres:\nZakres (1,0 – 99,5)%\nPozostałość po prażeniu / substancje mineralne (z obliczeń)\nMetoda wagowa","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: A. Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) B. Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. 2015, poz. 257) C. Rozporządzeniem Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. 2015, poz. 132) D. Rozporządzeniem Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. 2015, poz. 796) E. Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz. U. 2023, poz. 56) F. Rozporządzeniem Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. 2011 nr 175, poz. 1048) G. Rozporządzeniem Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. 2016, poz. 847) H. Rozporządzenie Ministra Klimatu i Środowiska z dnia 23 grudnia 2021 r. w sprawie określenia szczegółowych warunków utraty statusu odpadów dla odpadów destruktu asfaltowego (Dz. U. 2021, poz. 2468) I. Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz.U. 2017, poz. 2490) J. Rozporządzenie Ministra Rozwoju z dnia 21 stycznia 2016 r. w sprawie wymagań dotyczących prowadzenia procesu termicznego przekształcania odpadów oraz sposobów postępowania z odpadami powstałymi w wyniku tego procesu (Dz. U. 2016, poz. 108) DAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady zawierające związki ropopochodne (VIII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne nieorganiczne - kwasy, zasady, sole (XIII), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII), Odpady, E kod: 10 01 99, 16 81 01*, 16 81 02 Straty przy prażeniu suchej masy (LOI) / zawartość substancji organicznych A, B, C, D, E, G, I, J\nZakres:\nZakres (1,0 – 99,5)%\nPozostałość po prażeniu / substancje mineralne (z obliczeń)\nMetoda wagowa Normy M Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV), Odpady z przetwarzania odpadow (VI), Osady z procesow przemyslowych (VII), Osady zawierajace zwiazki ropopochodne (VIII), Osady sciekowe (IX), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne nieorganiczne - kwasy, zasady, sole (XIII), Odpady chemiczne – organiczne zmieszane (XIV), Odpady chemiczne – nieorganiczne zmieszane (XV), Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skory i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII), Odpady, E kod: 10 01 99, 16 81 01*, 16 81 02 Straty przy prazeniu suchej masy (LOI) / zawartosc substancji organicznych A, B, C, D, E, G, I, J\nZakres:\nZakres (1,0 – 99,5)%\nPozostalosc po prazeniu / substancje mineralne (z obliczen)\nMetoda wagowa Normy M","categories":["water","environment","food","materials","construction"],"row_index":294,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition of dry matter (LOI) / organic matter content A, B, C, D, E, G, I, J","parameters_en":[{"name":"Range","range":"(1,0 – 99,5)%"},{"name":"Residue on ignition / mineral substances (calculated)"}],"search_en":"Loss on ignition of dry matter (LOI) / organic matter content A, B, C, D, E, G, I, J Gravimetric method Range Residue on ignition / mineral substances (calculated) Normy M","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(1,0 – 99,5)%"},{"name":"灼烧残渣/矿物质（由计算得出）"}],"search_zh":"重量法 范围 灼烧残渣/矿物质（由计算得出） Normy M","technique_zh":"重量法"},{"_id":"6a82c6ff884ede9a1b2c2a73","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady DAB-11, E: Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Osady ściekowe (IX), Żużle, popioły i pyły paleniskowe (XI), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","methodology":"Zawartość azotu Kjeldahla B, C, D","parameters":[{"name":"Zakres","range":"(0,10 -10)%"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu Kjeldahla B, C, D\nZakres (0,10 -10)%\nMetoda miareczkowa","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: A. Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) B. Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. 2015, poz. 257) C. Rozporządzeniem Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. 2015, poz. 132) D. Rozporządzeniem Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. 2015, poz. 796) E. Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz. U. 2023, poz. 56) F. Rozporządzeniem Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. 2011 nr 175, poz. 1048) G. Rozporządzeniem Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. 2016, poz. 847) H. Rozporządzenie Ministra Klimatu i Środowiska z dnia 23 grudnia 2021 r. w sprawie określenia szczegółowych warunków utraty statusu odpadów dla odpadów destruktu asfaltowego (Dz. U. 2021, poz. 2468) I. Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz.U. 2017, poz. 2490) J. Rozporządzenie Ministra Rozwoju z dnia 21 stycznia 2016 r. w sprawie wymagań dotyczących prowadzenia procesu termicznego przekształcania odpadów oraz sposobów postępowania z odpadami powstałymi w wyniku tego procesu (Dz. U. 2016, poz. 108) DAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Odpady DAB-11, E: Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Osady ściekowe (IX), Żużle, popioły i pyły paleniskowe (XI), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Zawartość azotu Kjeldahla B, C, D\nZakres (0,10 -10)%\nMetoda miareczkowa Normy M Odpady DAB-11, E: Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV), Osady sciekowe (IX), Zuzle, popioly i pyly paleniskowe (XI), Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Zawartosc azotu Kjeldahla B, C, D\nZakres (0,10 -10)%\nMetoda miareczkowa Normy M","categories":["water","environment","food"],"row_index":295,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen content B, C, D","parameters_en":[{"name":"Range","range":"(0,10 -10)%"}],"search_en":"Kjeldahl nitrogen content B, C, D Titrimetric method Range Normy M","technique_en":"Titrimetric method","parameters_zh":[{"name":"范围","range":"(0,10 -10)%"}],"search_zh":"滴定法 范围 Normy M","technique_zh":"滴定法"},{"_id":"6a82c6ff884ede9a1b2c2a74","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Paliwa stałe: E stałe paliwa wtórne (SRF), surowce do produkcji paliw z odpadów, Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady zawierające związki ropopochodne (VIII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","methodology":"Ciepło spalania A,G","parameters":[{"name":"Zakres","range":"(3900 – 40 000) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania A,G\nZakres:\nZakres (3900 – 40 000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: A. Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) B. Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. 2015, poz. 257) C. Rozporządzeniem Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. 2015, poz. 132) D. Rozporządzeniem Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. 2015, poz. 796) E. Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz. U. 2023, poz. 56) F. Rozporządzeniem Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. 2011 nr 175, poz. 1048) G. Rozporządzeniem Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. 2016, poz. 847) H. Rozporządzenie Ministra Klimatu i Środowiska z dnia 23 grudnia 2021 r. w sprawie określenia szczegółowych warunków utraty statusu odpadów dla odpadów destruktu asfaltowego (Dz. U. 2021, poz. 2468) I. Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz.U. 2017, poz. 2490) J. Rozporządzenie Ministra Rozwoju z dnia 21 stycznia 2016 r. w sprawie wymagań dotyczących prowadzenia procesu termicznego przekształcania odpadów oraz sposobów postępowania z odpadami powstałymi w wyniku tego procesu (Dz. U. 2016, poz. 108) DAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Paliwa stałe: E stałe paliwa wtórne (SRF), surowce do produkcji paliw z odpadów, Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady zawierające związki ropopochodne (VIII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Ciepło spalania A,G\nZakres:\nZakres (3900 – 40 000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna Normy M Paliwa stale: E stale paliwa wtorne (SRF), surowce do produkcji paliw z odpadow, Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV), Odpady z przetwarzania odpadow (VI), Osady z procesow przemyslowych (VII), Osady zawierajace zwiazki ropopochodne (VIII), Osady sciekowe (IX), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skory i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Cieplo spalania A,G\nZakres:\nZakres (3900 – 40 000) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna Normy M","categories":["water","environment","food","materials","petro","construction"],"row_index":296,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value A,G","parameters_en":[{"name":"Range","range":"(3900 – 40 000) kJ/kg"},{"name":"Net calorific value (calculated)"}],"search_en":"Gross calorific value A,G Calorimetric method Range Net calorific value (calculated) Normy M","technique_en":"Calorimetric method","parameters_zh":[{"name":"范围","range":"(3900 – 40 000) kJ/kg"},{"name":"低位发热量（计算值）"}],"search_zh":"量热法 范围 低位发热量（计算值） Normy M","technique_zh":"量热法"},{"_id":"6a82c6ff884ede9a1b2c2a75","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Paliwa stałe: E stałe paliwa wtórne (SRF), surowce do produkcji paliw z odpadów, Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady zawierające związki ropopochodne (VIII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","methodology":"Zawartość wilgoci w próbce analitycznej G","parameters":[{"name":"Zakres","range":"(0,10 – 55,00) %"}],"technique":"Metoda termograwimetryczna","techniques":["Metoda termograwimetryczna"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej G\nZakres (0,10 – 55,00) %\nMetoda termograwimetryczna","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: A. Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) B. Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. 2015, poz. 257) C. Rozporządzeniem Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. 2015, poz. 132) D. Rozporządzeniem Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. 2015, poz. 796) E. Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz. U. 2023, poz. 56) F. Rozporządzeniem Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. 2011 nr 175, poz. 1048) G. Rozporządzeniem Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. 2016, poz. 847) H. Rozporządzenie Ministra Klimatu i Środowiska z dnia 23 grudnia 2021 r. w sprawie określenia szczegółowych warunków utraty statusu odpadów dla odpadów destruktu asfaltowego (Dz. U. 2021, poz. 2468) I. Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz.U. 2017, poz. 2490) J. Rozporządzenie Ministra Rozwoju z dnia 21 stycznia 2016 r. w sprawie wymagań dotyczących prowadzenia procesu termicznego przekształcania odpadów oraz sposobów postępowania z odpadami powstałymi w wyniku tego procesu (Dz. U. 2016, poz. 108) DAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Paliwa stałe: E stałe paliwa wtórne (SRF), surowce do produkcji paliw z odpadów, Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady zawierające związki ropopochodne (VIII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Zawartość wilgoci w próbce analitycznej G\nZakres (0,10 – 55,00) %\nMetoda termograwimetryczna Normy M Paliwa stale: E stale paliwa wtorne (SRF), surowce do produkcji paliw z odpadow, Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV), Odpady z przetwarzania odpadow (VI), Osady z procesow przemyslowych (VII), Osady zawierajace zwiazki ropopochodne (VIII), Osady sciekowe (IX), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skory i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Zawartosc wilgoci w probce analitycznej G\nZakres (0,10 – 55,00) %\nMetoda termograwimetryczna Normy M","categories":["water","environment","food","materials","petro","construction"],"row_index":297,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample G","parameters_en":[{"name":"Range","range":"(0,10 – 55,00) %"}],"search_en":"Moisture content in the analytical sample G Thermogravimetric method Range Normy M","technique_en":"Thermogravimetric method","parameters_zh":[{"name":"范围","range":"(0,10 – 55,00) %"}],"search_zh":"热重法 范围 Normy M","technique_zh":"热重法"},{"_id":"6a82c6ff884ede9a1b2c2a76","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Paliwa stałe: E stałe paliwa wtórne (SRF), surowce do produkcji paliw z odpadów, Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady zawierające związki ropopochodne (VIII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","methodology":"Zawartość popiołu G","parameters":[{"name":"Zakres","range":"(1,50 – 95,00) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość popiołu G\nZakres (1,50 – 95,00) %\nMetoda termograwimetryczna (TGA)","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: A. Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) B. Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. 2015, poz. 257) C. Rozporządzeniem Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. 2015, poz. 132) D. Rozporządzeniem Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. 2015, poz. 796) E. Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz. U. 2023, poz. 56) F. Rozporządzeniem Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. 2011 nr 175, poz. 1048) G. Rozporządzeniem Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. 2016, poz. 847) H. Rozporządzenie Ministra Klimatu i Środowiska z dnia 23 grudnia 2021 r. w sprawie określenia szczegółowych warunków utraty statusu odpadów dla odpadów destruktu asfaltowego (Dz. U. 2021, poz. 2468) I. Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz.U. 2017, poz. 2490) J. Rozporządzenie Ministra Rozwoju z dnia 21 stycznia 2016 r. w sprawie wymagań dotyczących prowadzenia procesu termicznego przekształcania odpadów oraz sposobów postępowania z odpadami powstałymi w wyniku tego procesu (Dz. U. 2016, poz. 108) DAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Paliwa stałe: E stałe paliwa wtórne (SRF), surowce do produkcji paliw z odpadów, Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady zawierające związki ropopochodne (VIII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Zawartość popiołu G\nZakres (1,50 – 95,00) %\nMetoda termograwimetryczna (TGA) Normy M Paliwa stale: E stale paliwa wtorne (SRF), surowce do produkcji paliw z odpadow, Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV), Odpady z przetwarzania odpadow (VI), Osady z procesow przemyslowych (VII), Osady zawierajace zwiazki ropopochodne (VIII), Osady sciekowe (IX), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skory i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Zawartosc popiolu G\nZakres (1,50 – 95,00) %\nMetoda termograwimetryczna (TGA) Normy M","categories":["water","environment","food","materials","petro","construction"],"row_index":298,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content G","parameters_en":[{"name":"Range","range":"(1,50 – 95,00) %"}],"search_en":"Ash content G Thermogravimetric method (TGA) Range Normy M","technique_en":"Thermogravimetric method (TGA)","parameters_zh":[{"name":"范围","range":"(1,50 – 95,00) %"}],"search_zh":"热重法（TGA） 范围 Normy M","technique_zh":"热重法（TGA）"},{"_id":"6a82c6ff884ede9a1b2c2a77","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Paliwa stałe: E stałe paliwa wtórne (SRF), surowce do produkcji paliw z odpadów, Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady zawierające związki ropopochodne (VIII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","methodology":"Zawartość węgla całkowitego G","parameters":[{"name":"Zakres","range":"(1,0 – 95,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego G\nZakres (1,0 – 95,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: A. Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) B. Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. 2015, poz. 257) C. Rozporządzeniem Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. 2015, poz. 132) D. Rozporządzeniem Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. 2015, poz. 796) E. Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz. U. 2023, poz. 56) F. Rozporządzeniem Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. 2011 nr 175, poz. 1048) G. Rozporządzeniem Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. 2016, poz. 847) H. Rozporządzenie Ministra Klimatu i Środowiska z dnia 23 grudnia 2021 r. w sprawie określenia szczegółowych warunków utraty statusu odpadów dla odpadów destruktu asfaltowego (Dz. U. 2021, poz. 2468) I. Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz.U. 2017, poz. 2490) J. Rozporządzenie Ministra Rozwoju z dnia 21 stycznia 2016 r. w sprawie wymagań dotyczących prowadzenia procesu termicznego przekształcania odpadów oraz sposobów postępowania z odpadami powstałymi w wyniku tego procesu (Dz. U. 2016, poz. 108) DAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Paliwa stałe: E stałe paliwa wtórne (SRF), surowce do produkcji paliw z odpadów, Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady zawierające związki ropopochodne (VIII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Zawartość węgla całkowitego G\nZakres (1,0 – 95,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR Normy M Paliwa stale: E stale paliwa wtorne (SRF), surowce do produkcji paliw z odpadow, Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV), Odpady z przetwarzania odpadow (VI), Osady z procesow przemyslowych (VII), Osady zawierajace zwiazki ropopochodne (VIII), Osady sciekowe (IX), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skory i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Zawartosc wegla calkowitego G\nZakres (1,0 – 95,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR Normy M","categories":["water","environment","food","materials","petro","construction"],"row_index":299,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content G","parameters_en":[{"name":"Range","range":"(1,0 – 95,0) %"}],"search_en":"Total carbon content G High-temperature combustion with IR detection Range Normy M","technique_en":"High-temperature combustion with IR detection","parameters_zh":[{"name":"范围","range":"(1,0 – 95,0) %"}],"search_zh":"高温燃烧红外检测法 范围 Normy M","technique_zh":"高温燃烧红外检测法"},{"_id":"6a82c6ff884ede9a1b2c2a78","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Paliwa stałe: E stałe paliwa wtórne (SRF), surowce do produkcji paliw z odpadów, Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady zawierające związki ropopochodne (VIII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","methodology":"Zawartość wodoru G","parameters":[{"name":"Zakres","range":"(0,30 – 12,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość wodoru G\nZakres (0,30 – 12,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: A. Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) B. Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. 2015, poz. 257) C. Rozporządzeniem Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. 2015, poz. 132) D. Rozporządzeniem Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. 2015, poz. 796) E. Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz. U. 2023, poz. 56) F. Rozporządzeniem Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. 2011 nr 175, poz. 1048) G. Rozporządzeniem Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. 2016, poz. 847) H. Rozporządzenie Ministra Klimatu i Środowiska z dnia 23 grudnia 2021 r. w sprawie określenia szczegółowych warunków utraty statusu odpadów dla odpadów destruktu asfaltowego (Dz. U. 2021, poz. 2468) I. Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz.U. 2017, poz. 2490) J. Rozporządzenie Ministra Rozwoju z dnia 21 stycznia 2016 r. w sprawie wymagań dotyczących prowadzenia procesu termicznego przekształcania odpadów oraz sposobów postępowania z odpadami powstałymi w wyniku tego procesu (Dz. U. 2016, poz. 108) DAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Paliwa stałe: E stałe paliwa wtórne (SRF), surowce do produkcji paliw z odpadów, Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady zawierające związki ropopochodne (VIII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Zawartość wodoru G\nZakres (0,30 – 12,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR Normy M Paliwa stale: E stale paliwa wtorne (SRF), surowce do produkcji paliw z odpadow, Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV), Odpady z przetwarzania odpadow (VI), Osady z procesow przemyslowych (VII), Osady zawierajace zwiazki ropopochodne (VIII), Osady sciekowe (IX), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skory i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Zawartosc wodoru G\nZakres (0,30 – 12,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR Normy M","categories":["water","environment","food","materials","petro","construction"],"row_index":300,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen content G","parameters_en":[{"name":"Range","range":"(0,30 – 12,00) %"}],"search_en":"Hydrogen content G High-temperature combustion with IR detection Range Normy M","technique_en":"High-temperature combustion with IR detection","parameters_zh":[{"name":"范围","range":"(0,30 – 12,00) %"}],"search_zh":"高温燃烧红外检测法 范围 Normy M","technique_zh":"高温燃烧红外检测法"},{"_id":"6a82c6ff884ede9a1b2c2a79","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Paliwa stałe: E stałe paliwa wtórne (SRF), surowce do produkcji paliw z odpadów, Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady zawierające związki ropopochodne (VIII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","methodology":"Zawartość siarki całkowitej G","parameters":[{"name":"Zakres","range":"(0,01 – 5,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej G\nZakres (0,01 – 5,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: A. Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) B. Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. 2015, poz. 257) C. Rozporządzeniem Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. 2015, poz. 132) D. Rozporządzeniem Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. 2015, poz. 796) E. Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz. U. 2023, poz. 56) F. Rozporządzeniem Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. 2011 nr 175, poz. 1048) G. Rozporządzeniem Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. 2016, poz. 847) H. Rozporządzenie Ministra Klimatu i Środowiska z dnia 23 grudnia 2021 r. w sprawie określenia szczegółowych warunków utraty statusu odpadów dla odpadów destruktu asfaltowego (Dz. U. 2021, poz. 2468) I. Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz.U. 2017, poz. 2490) J. Rozporządzenie Ministra Rozwoju z dnia 21 stycznia 2016 r. w sprawie wymagań dotyczących prowadzenia procesu termicznego przekształcania odpadów oraz sposobów postępowania z odpadami powstałymi w wyniku tego procesu (Dz. U. 2016, poz. 108) DAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Paliwa stałe: E stałe paliwa wtórne (SRF), surowce do produkcji paliw z odpadów, Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady zawierające związki ropopochodne (VIII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Zawartość siarki całkowitej G\nZakres (0,01 – 5,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR Normy M Paliwa stale: E stale paliwa wtorne (SRF), surowce do produkcji paliw z odpadow, Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV), Odpady z przetwarzania odpadow (VI), Osady z procesow przemyslowych (VII), Osady zawierajace zwiazki ropopochodne (VIII), Osady sciekowe (IX), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skory i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Zawartosc siarki calkowitej G\nZakres (0,01 – 5,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR Normy M","categories":["water","environment","food","materials","petro","construction"],"row_index":301,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulphur content G","parameters_en":[{"name":"Range","range":"(0,01 – 5,00) %"}],"search_en":"Total sulphur content G High-temperature combustion with IR detection Range Normy M","technique_en":"High-temperature combustion with IR detection","parameters_zh":[{"name":"范围","range":"(0,01 – 5,00) %"}],"search_zh":"高温燃烧红外检测法 范围 Normy M","technique_zh":"高温燃烧红外检测法"},{"_id":"6a82c6ff884ede9a1b2c2a7a","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Paliwa stałe: E stałe paliwa wtórne (SRF), surowce do produkcji paliw z odpadów, Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady zawierające związki ropopochodne (VIII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","methodology":"Zawartość biomasy – udział masowy G","parameters":[{"name":"Zakres","range":"(15,0 – 100) %"},{"name":"Zawartość nie-biomasy (z obliczeń)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość biomasy – udział masowy G\nZakres:\nZakres (15,0 – 100) %\nZawartość nie-biomasy (z obliczeń)\nMetoda wagowa","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: A. Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) B. Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. 2015, poz. 257) C. Rozporządzeniem Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. 2015, poz. 132) D. Rozporządzeniem Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. 2015, poz. 796) E. Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz. U. 2023, poz. 56) F. Rozporządzeniem Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. 2011 nr 175, poz. 1048) G. Rozporządzeniem Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. 2016, poz. 847) H. Rozporządzenie Ministra Klimatu i Środowiska z dnia 23 grudnia 2021 r. w sprawie określenia szczegółowych warunków utraty statusu odpadów dla odpadów destruktu asfaltowego (Dz. U. 2021, poz. 2468) I. Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz.U. 2017, poz. 2490) J. Rozporządzenie Ministra Rozwoju z dnia 21 stycznia 2016 r. w sprawie wymagań dotyczących prowadzenia procesu termicznego przekształcania odpadów oraz sposobów postępowania z odpadami powstałymi w wyniku tego procesu (Dz. U. 2016, poz. 108) DAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Paliwa stałe: E stałe paliwa wtórne (SRF), surowce do produkcji paliw z odpadów, Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady zawierające związki ropopochodne (VIII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Zawartość biomasy – udział masowy G\nZakres:\nZakres (15,0 – 100) %\nZawartość nie-biomasy (z obliczeń)\nMetoda wagowa Normy M Paliwa stale: E stale paliwa wtorne (SRF), surowce do produkcji paliw z odpadow, Odpady DAB-11, E: Osady i odpady mineralne (I), Odpady budowlane (III), Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV), Odpady z przetwarzania odpadow (VI), Osady z procesow przemyslowych (VII), Osady zawierajace zwiazki ropopochodne (VIII), Osady sciekowe (IX), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skory i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Zawartosc biomasy – udzial masowy G\nZakres:\nZakres (15,0 – 100) %\nZawartosc nie-biomasy (z obliczen)\nMetoda wagowa Normy M","categories":["water","environment","food","materials","petro","construction"],"row_index":302,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biomass content – mass fraction G","parameters_en":[{"name":"Range","range":"(15,0 – 100) %"},{"name":"Non-biomass content (calculated)"}],"search_en":"Biomass content – mass fraction G Gravimetric method Range Non-biomass content (calculated) Normy M","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(15,0 – 100) %"},{"name":"Zawartość nie-biomasy (z obliczeń)"}],"search_zh":"重量法 范围 Normy M","technique_zh":"重量法"},{"_id":"6a82c6ff884ede9a1b2c2a7b","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Konserwy warzywno-mięsne, warzywne, owocowe","methodology":"Trwałość konserw","parameters":[],"technique":"Metoda próby termostatowej","techniques":["Metoda próby termostatowej"],"computed":[],"activity":"Trwałość konserw\nMetoda próby termostatowej","reference":"PN-A-75052-03:1990 Ł","norm_bases":["PN-A-75052-03:1990 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Konserwy warzywno-mięsne, warzywne, owocowe Trwałość konserw\nMetoda próby termostatowej PN-A-75052-03:1990 Ł Konserwy warzywno-miesne, warzywne, owocowe Trwalosc konserw\nMetoda proby termostatowej PN-A-75052-03:1990 L","categories":["other"],"row_index":303,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Shelf stability of canned products","search_en":"Canned vegetable-meat, vegetable and fruit products Shelf stability of canned products Thermostatic test method PN-A-75052-03:1990 Ł","technique_en":"Thermostatic test method","test_object_en":"Canned vegetable-meat, vegetable and fruit products","methodology_zh":"罐头保存性","search_zh":"罐头保存性 恒温试验法 PN-A-75052-03:1990 Ł","technique_zh":"恒温试验法"},{"_id":"6a82c6ff884ede9a1b2c2a7c","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Konserwy rybne","methodology":"Trwałość konserw","parameters":[],"technique":"Metoda próby termostatowej","techniques":["Metoda próby termostatowej"],"computed":[],"activity":"Trwałość konserw\nMetoda próby termostatowej","reference":"PN-A-86732:1992 pkt. 2.3.11 Ł","norm_bases":["PN-A-86732:1992 pkt. 2.3.11 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Konserwy rybne Trwałość konserw\nMetoda próby termostatowej PN-A-86732:1992 pkt. 2.3.11 Ł Konserwy rybne Trwalosc konserw\nMetoda proby termostatowej PN-A-86732:1992 pkt. 2.3.11 L","categories":["other"],"row_index":304,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Shelf stability of canned products","search_en":"Canned fish Shelf stability of canned products Thermostatic test method PN-A-86732:1992 pkt. 2.3.11 Ł","technique_en":"Thermostatic test method","test_object_en":"Canned fish","methodology_zh":"罐头保存性","search_zh":"鱼罐头 罐头保存性 恒温试验法 PN-A-86732:1992 pkt. 2.3.11 Ł","technique_zh":"恒温试验法","test_object_zh":"鱼罐头"},{"_id":"6a82c6ff884ede9a1b2c2a7d","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Konserwy mięsne","methodology":"Trwałość konserw","parameters":[],"technique":"Metoda próby termostatowej","techniques":["Metoda próby termostatowej"],"computed":[],"activity":"Trwałość konserw\nMetoda próby termostatowej","reference":"PN-A-82055-5:1994 Ł","norm_bases":["PN-A-82055-5:1994 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Konserwy mięsne Trwałość konserw\nMetoda próby termostatowej PN-A-82055-5:1994 Ł Konserwy miesne Trwalosc konserw\nMetoda proby termostatowej PN-A-82055-5:1994 L","categories":["other"],"row_index":305,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Shelf stability of canned products","search_en":"Canned meat Shelf stability of canned products Thermostatic test method PN-A-82055-5:1994 Ł","technique_en":"Thermostatic test method","test_object_en":"Canned meat","methodology_zh":"罐头保存性","search_zh":"肉类罐头 罐头保存性 恒温试验法 PN-A-82055-5:1994 Ł","technique_zh":"恒温试验法","test_object_zh":"肉类罐头"},{"_id":"6a82c6ff884ede9a1b2c2a7e","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Mleko i produkty mleczne","methodology":"Trwałość produktu","parameters":[],"technique":"Metoda próby termostatowej","techniques":["Metoda próby termostatowej"],"computed":[],"activity":"Trwałość produktu\nMetoda próby termostatowej","reference":"PN-A-86034-03:1993 Ł","norm_bases":["PN-A-86034-03:1993 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko i produkty mleczne Trwałość produktu\nMetoda próby termostatowej PN-A-86034-03:1993 Ł Mleko i produkty mleczne Trwalosc produktu\nMetoda proby termostatowej PN-A-86034-03:1993 L","categories":["food"],"row_index":306,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Product durability","search_en":"Milk and milk products Product durability Thermostatic test method PN-A-86034-03:1993 Ł","technique_en":"Thermostatic test method","test_object_en":"Milk and milk products","search_zh":"乳与乳制品 恒温试验法 PN-A-86034-03:1993 Ł","technique_zh":"恒温试验法","test_object_zh":"乳与乳制品"},{"_id":"6a82c6ff884ede9a1b2c2a7f","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Mleko i przetwory mleczne","methodology":"Obecność antybiotyków i innych substancji hamujących testem, Delvotest SP","parameters":[],"technique":"Metoda dyfuzyjna","techniques":["Metoda dyfuzyjna"],"computed":[],"activity":"Obecność antybiotyków i innych substancji hamujących testem, Delvotest SP\nMetoda dyfuzyjna","reference":"PN-A-86033:2002 Ł","norm_bases":["PN-A-86033:2002 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko i przetwory mleczne Obecność antybiotyków i innych substancji hamujących testem, Delvotest SP\nMetoda dyfuzyjna PN-A-86033:2002 Ł Mleko i przetwory mleczne Obecnosc antybiotykow i innych substancji hamujacych testem, Delvotest SP\nMetoda dyfuzyjna PN-A-86033:2002 L","categories":["food"],"row_index":307,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of antibiotics and other inhibitory substances by test, Delvotest SP","search_en":"Milk and milk products Presence of antibiotics and other inhibitory substances by test, Delvotest SP Diffusion method PN-A-86033:2002 Ł","technique_en":"Diffusion method","test_object_en":"Milk and milk products","search_zh":"乳与乳制品 扩散法 PN-A-86033:2002 Ł","technique_zh":"扩散法","test_object_zh":"乳与乳制品"},{"_id":"6a82c6ff884ede9a1b2c2a80","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Ryby i produkty rybne, Mięso i produkty mięsne, Jaja i produkty jajeczne, Pasze","methodology":"Obecność antybiotyków i innych substancji hamujących","parameters":[],"technique":"Metoda dyfuzyjna (Premi Test)","techniques":["Metoda dyfuzyjna (Premi Test)"],"computed":[],"activity":"Obecność antybiotyków i innych substancji hamujących\nMetoda dyfuzyjna (Premi Test)","reference":"Instrukcja testu PremiTest firmy R-Biopharm AG Ł","norm_bases":["Instrukcja testu PremiTest firmy R-Biopharm AG Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ryby i produkty rybne, Mięso i produkty mięsne, Jaja i produkty jajeczne, Pasze Obecność antybiotyków i innych substancji hamujących\nMetoda dyfuzyjna (Premi Test) Instrukcja testu PremiTest firmy R-Biopharm AG Ł Ryby i produkty rybne, Mieso i produkty miesne, Jaja i produkty jajeczne, Pasze Obecnosc antybiotykow i innych substancji hamujacych\nMetoda dyfuzyjna (Premi Test) Instrukcja testu PremiTest firmy R-Biopharm AG L","categories":["food"],"row_index":308,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of antibiotics and other inhibitory substances","search_en":"Fish and fish products, Meat and meat products, Eggs and egg products, Feed Presence of antibiotics and other inhibitory substances Diffusion method (Premi Test) Instrukcja testu PremiTest firmy R-Biopharm AG Ł","technique_en":"Diffusion method (Premi Test)","test_object_en":"Fish and fish products, Meat and meat products, Eggs and egg products, Feed","methodology_zh":"抗生素及其他抑菌物质的检出","search_zh":"抗生素及其他抑菌物质的检出 Instrukcja testu PremiTest firmy R-Biopharm AG Ł"},{"_id":"6a82c6ff884ede9a1b2c2a81","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Przetwory owocowe, warzywne i warzywno – mięsne","methodology":"Obecność bakterii octowych","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność bakterii octowych\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-A-75052-15:1990 Ł","norm_bases":["PN-A-75052-15:1990 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory owocowe, warzywne i warzywno – mięsne Obecność bakterii octowych\nMetoda hodowlana z potwierdzeniem biochemicznym PN-A-75052-15:1990 Ł Przetwory owocowe, warzywne i warzywno – miesne Obecnosc bakterii octowych\nMetoda hodowlana z potwierdzeniem biochemicznym PN-A-75052-15:1990 L","categories":["microbiology"],"row_index":309,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of acetic acid bacteria","search_en":"Fruit, vegetable and vegetable – meat products Presence of acetic acid bacteria Culture method with biochemical confirmation PN-A-75052-15:1990 Ł","technique_en":"Culture method with biochemical confirmation","test_object_en":"Fruit, vegetable and vegetable – meat products","search_zh":"培养法结合生化确认 PN-A-75052-15:1990 Ł","technique_zh":"培养法结合生化确认"},{"_id":"6a82c6ff884ede9a1b2c2a82","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Napoje bezalkoholowe, w tym soki, nektary owocowe oraz warzywne, Surowce do produkcji napojów i soków, Owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, Cukier i produkty pochodne","methodology":"Liczba termofilnych kwasolubnych bakterii przetrwalnikujących (Alicyclobacillus spp.) Metoda filtracji membranowej – procedura B","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Liczba termofilnych kwasolubnych bakterii przetrwalnikujących (Alicyclobacillus spp.) Metoda filtracji membranowej – procedura B","reference":"IFU No. 12 (2019) Ł","norm_bases":["IFU No. 12 (2019) Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje bezalkoholowe, w tym soki, nektary owocowe oraz warzywne, Surowce do produkcji napojów i soków, Owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, Cukier i produkty pochodne Liczba termofilnych kwasolubnych bakterii przetrwalnikujących (Alicyclobacillus spp.) Metoda filtracji membranowej – procedura B IFU No. 12 (2019) Ł Napoje bezalkoholowe, w tym soki, nektary owocowe oraz warzywne, Surowce do produkcji napojow i sokow, Owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-miesne, Cukier i produkty pochodne Liczba termofilnych kwasolubnych bakterii przetrwalnikujacych (Alicyclobacillus spp.) Metoda filtracji membranowej – procedura B IFU No. 12 (2019) L","categories":["food","microbiology"],"row_index":310,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of thermophilic acidophilic spore-forming bacteria (Alicyclobacillus spp.) Membrane filtration method – procedure B","search_en":"Non-alcoholic beverages, including juices, fruit and vegetable nectars, Raw materials for the production of beverages and juices, Fruit and vegetables and fruit and vegetable products and vegetable-meat products, Sugar and derived products Count of thermophilic acidophilic spore-forming bacteria (Alicyclobacillus spp.) Membrane filtration method – procedure B IFU No. 12 (2019) Ł","test_object_en":"Non-alcoholic beverages, including juices, fruit and vegetable nectars, Raw materials for the production of beverages and juices, Fruit and vegetables and fruit and vegetable products and vegetable-meat products, Sugar and derived products"},{"_id":"6a82c6ff884ede9a1b2c2a83","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Napoje bezalkoholowe, w tym soki, nektary owocowe oraz warzywne, Surowce do produkcji napojów i soków, Owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, Cukier i produkty pochodne","methodology":"Liczba termofilnych kwasolubnych bakterii przetrwalnikujących (Alicyclobacillus spp.) wytwarzających gwajakol","parameters":[],"technique":"Metoda filtracji membranowej z potwierdzeniem biochemicznym – procedura B","techniques":["Metoda filtracji membranowej z potwierdzeniem biochemicznym – procedura B"],"computed":[],"activity":"Liczba termofilnych kwasolubnych bakterii przetrwalnikujących (Alicyclobacillus spp.) wytwarzających gwajakol\nMetoda filtracji membranowej z potwierdzeniem biochemicznym – procedura B","reference":"IFU No. 12 (2019) Ł","norm_bases":["IFU No. 12 (2019) Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje bezalkoholowe, w tym soki, nektary owocowe oraz warzywne, Surowce do produkcji napojów i soków, Owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, Cukier i produkty pochodne Liczba termofilnych kwasolubnych bakterii przetrwalnikujących (Alicyclobacillus spp.) wytwarzających gwajakol\nMetoda filtracji membranowej z potwierdzeniem biochemicznym – procedura B IFU No. 12 (2019) Ł Napoje bezalkoholowe, w tym soki, nektary owocowe oraz warzywne, Surowce do produkcji napojow i sokow, Owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-miesne, Cukier i produkty pochodne Liczba termofilnych kwasolubnych bakterii przetrwalnikujacych (Alicyclobacillus spp.) wytwarzajacych gwajakol\nMetoda filtracji membranowej z potwierdzeniem biochemicznym – procedura B IFU No. 12 (2019) L","categories":["food","microbiology"],"row_index":311,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of thermophilic acidophilic spore-forming bacteria (Alicyclobacillus spp.) producing guaiacol","search_en":"Non-alcoholic beverages, including juices, fruit and vegetable nectars, Raw materials for the production of beverages and juices, Fruit and vegetables and fruit and vegetable products and vegetable-meat products, Sugar and derived products Count of thermophilic acidophilic spore-forming bacteria (Alicyclobacillus spp.) producing guaiacol Membrane filtration method with biochemical confirmation – procedure B IFU No. 12 (2019) Ł","technique_en":"Membrane filtration method with biochemical confirmation – procedure B","test_object_en":"Non-alcoholic beverages, including juices, fruit and vegetable nectars, Raw materials for the production of beverages and juices, Fruit and vegetables and fruit and vegetable products and vegetable-meat products, Sugar and derived products","methodology_zh":"产生愈创木酚的嗜热嗜酸芽孢杆菌（Alicyclobacillus spp.）数","search_zh":"产生愈创木酚的嗜热嗜酸芽孢杆菌（Alicyclobacillus spp.）数 IFU No. 12 (2019) Ł"},{"_id":"6a82c6ff884ede9a1b2c2a84","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba colifagów somatycznych","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba colifagów somatycznych\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 10705-2:2005 | PN-ISO 10705-3:2021-01 Ł","norm_bases":["PN-EN ISO 10705-2:2005","PN-ISO 10705-3:2021-01 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba colifagów somatycznych\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 10705-2:2005 | PN-ISO 10705-3:2021-01 Ł Woda, Woda do spozycia przez ludzi Liczba colifagow somatycznych\nMetoda plytkowa (posiew wglebny) PN-EN ISO 10705-2:2005 | PN-ISO 10705-3:2021-01 L","categories":["water"],"row_index":312,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Somatic coliphage count","search_en":"Water, Water intended for human consumption Somatic coliphage count Plate method (pour plate) PN-EN ISO 10705-2:2005 | PN-ISO 10705-3:2021-01 Ł","technique_en":"Plate method (pour plate)","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 体细胞噬菌体数 平板法（倾注培养） PN-EN ISO 10705-2:2005 | PN-ISO 10705-3:2021-01 Ł","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水","methodology_zh":"体细胞噬菌体数"},{"_id":"6a82c6ff884ede9a1b2c2a85","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E, Koncentrat do dializ, płyn do dializ, woda do dializ E","methodology":"Liczba bakterii mezofilnych","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba bakterii mezofilnych\nMetoda płytkowa (posiew wgłębny)","reference":"PB-01/LM Ł","norm_bases":["PB-01/LM Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E, Koncentrat do dializ, płyn do dializ, woda do dializ E Liczba bakterii mezofilnych\nMetoda płytkowa (posiew wgłębny) PB-01/LM Ł Woda E, Woda do spozycia przez ludzi E, Koncentrat do dializ, plyn do dializ, woda do dializ E Liczba bakterii mezofilnych\nMetoda plytkowa (posiew wglebny) PB-01/LM L","categories":["water","microbiology"],"row_index":313,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of mesophilic bacteria","search_en":"Count of mesophilic bacteria Plate method (pour plate) PB-01/LM Ł","technique_en":"Plate method (pour plate)","search_zh":"平板法（倾注培养） PB-01/LM Ł","technique_zh":"平板法（倾注培养）"},{"_id":"6a82c6ff884ede9a1b2c2a86","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E, Koncentrat do dializ, płyn do dializ, woda do dializ E","methodology":"Liczba bakterii psychrofilnych","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba bakterii psychrofilnych\nMetoda płytkowa (posiew wgłębny)","reference":"Ł","norm_bases":["Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E, Koncentrat do dializ, płyn do dializ, woda do dializ E Liczba bakterii psychrofilnych\nMetoda płytkowa (posiew wgłębny) Ł Woda E, Woda do spozycia przez ludzi E, Koncentrat do dializ, plyn do dializ, woda do dializ E Liczba bakterii psychrofilnych\nMetoda plytkowa (posiew wglebny) L","categories":["water","microbiology"],"row_index":314,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of psychrophilic bacteria","search_en":"Count of psychrophilic bacteria Plate method (pour plate) Ł","technique_en":"Plate method (pour plate)","search_zh":"平板法（倾注培养） Ł","technique_zh":"平板法（倾注培养）"},{"_id":"6a82c6ff884ede9a1b2c2a87","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Ogólna liczba mikroorganizmów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów\nMetoda płytkowa (posiew wgłębny)","reference":"Ł","norm_bases":["Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Ogólna liczba mikroorganizmów\nMetoda płytkowa (posiew wgłębny) Ł Woda E, Woda do spozycia przez ludzi E Ogolna liczba mikroorganizmow\nMetoda plytkowa (posiew wglebny) L","categories":["water"],"row_index":315,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total microorganism count","search_en":"Water E, Water intended for human consumption E Total microorganism count Plate method (pour plate) Ł","technique_en":"Plate method (pour plate)","test_object_en":"Water E, Water intended for human consumption E","search_zh":"水 E、生活饮用水 E 微生物总数 平板法（倾注培养） Ł","technique_zh":"平板法（倾注培养）","test_object_zh":"水 E、生活饮用水 E","methodology_zh":"微生物总数"},{"_id":"6a82c6ff884ede9a1b2c2a88","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Koncentrat do dializ, płyn do dializ, woda do dializ E","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266 Ł","norm_bases":["PN-EN ISO 16266 Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Koncentrat do dializ, płyn do dializ, woda do dializ E Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266 Ł Koncentrat do dializ, plyn do dializ, woda do dializ E Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266 L","categories":["water"],"row_index":316,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pseudomonas aeruginosa count","search_en":"Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266 Ł","technique_en":"Membrane filtration method","methodology_zh":"铜绿假单胞菌计数","search_zh":"铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266 Ł","technique_zh":"膜过滤法"},{"_id":"6a82c6ff884ede9a1b2c2a89","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Koncentrat do dializ, płyn do dializ, woda do dializ E","methodology":"Najbardziej prawdopodobna liczba drobnoustrojów","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda NPL","reference":"Normy | PB-02/LM Ł","norm_bases":["Normy","PB-02/LM Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Koncentrat do dializ, płyn do dializ, woda do dializ E Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda NPL Normy | PB-02/LM Ł Koncentrat do dializ, plyn do dializ, woda do dializ E Najbardziej prawdopodobna liczba drobnoustrojow\nMetoda NPL Normy | PB-02/LM L","categories":["water","microbiology"],"row_index":317,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of microorganisms","search_en":"Most probable number of microorganisms MPN method Normy | PB-02/LM Ł","technique_en":"MPN method","search_zh":"微生物最可能数 最可能数法（MPN） Normy | PB-02/LM Ł","technique_zh":"最可能数法（MPN）","methodology_zh":"微生物最可能数"},{"_id":"6a82c6ff884ede9a1b2c2a8a","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Koncentrat do dializ, płyn do dializ, woda do dializ E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PB-02/LM Ł","norm_bases":["PB-02/LM Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Koncentrat do dializ, płyn do dializ, woda do dializ E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym PB-02/LM Ł Koncentrat do dializ, plyn do dializ, woda do dializ E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym PB-02/LM L","categories":["water","microbiology"],"row_index":318,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of microorganisms","search_en":"Presence of microorganisms Culture method with biochemical confirmation PB-02/LM Ł","technique_en":"Culture method with biochemical confirmation","search_zh":"微生物的检出 培养法结合生化确认 PB-02/LM Ł","technique_zh":"培养法结合生化确认","methodology_zh":"微生物的检出"},{"_id":"6a82c6ff884ede9a1b2c2a8b","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością – wymazy E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda filtracji membranowej","reference":"Normy Ł","norm_bases":["Normy Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością – wymazy E Liczba drobnoustrojów\nMetoda filtracji membranowej Normy Ł Woda E, Woda do spozycia przez ludzi E, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia oraz z obszarow niezwiazanych z zywnoscia – wymazy E Liczba drobnoustrojow\nMetoda filtracji membranowej Normy L","categories":["water","food","environment","microbiology"],"row_index":319,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Microorganism count Membrane filtration method Normy Ł","technique_en":"Membrane filtration method","methodology_zh":"菌落总数","search_zh":"菌落总数 膜过滤法 Normy Ł","technique_zh":"膜过滤法"},{"_id":"6a82c6ff884ede9a1b2c2a8c","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Normy Ł","norm_bases":["Normy Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Normy Ł Woda E, Woda do spozycia przez ludzi E Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Normy L","categories":["water","microbiology"],"row_index":320,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Water E, Water intended for human consumption E Microorganism count Plate method (pour plate) Normy Ł","technique_en":"Plate method (pour plate)","test_object_en":"Water E, Water intended for human consumption E","methodology_zh":"菌落总数","search_zh":"水 E、生活饮用水 E 菌落总数 平板法（倾注培养） Normy Ł","technique_zh":"平板法（倾注培养）","test_object_zh":"水 E、生活饮用水 E"},{"_id":"6a82c6ff884ede9a1b2c2a8d","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Obecność i liczba drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem: - biochemicznym i serologicznym - biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem: - biochemicznym i serologicznym - biochemicznym"],"computed":[],"activity":"Obecność i liczba drobnoustrojów\nMetoda hodowlana z potwierdzeniem: - biochemicznym i serologicznym - biochemicznym","reference":"Normy Procedury badawcze Ł","norm_bases":["Normy Procedury badawcze Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Obecność i liczba drobnoustrojów\nMetoda hodowlana z potwierdzeniem: - biochemicznym i serologicznym - biochemicznym Normy Procedury badawcze Ł Woda E, Woda do spozycia przez ludzi E Obecnosc i liczba drobnoustrojow\nMetoda hodowlana z potwierdzeniem: - biochemicznym i serologicznym - biochemicznym Normy Procedury badawcze L","categories":["water","microbiology"],"row_index":321,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence and count of microorganisms","search_en":"Water E, Water intended for human consumption E Presence and count of microorganisms Culture method with confirmation: - biochemical and serological - biochemical Normy Procedury badawcze Ł","technique_en":"Culture method with confirmation: - biochemical and serological - biochemical","test_object_en":"Water E, Water intended for human consumption E","search_zh":"水 E、生活饮用水 E Normy Procedury badawcze Ł","test_object_zh":"水 E、生活饮用水 E"},{"_id":"6a82c6ff884ede9a1b2c2a8e","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Najbardziej prawdopodobna liczba drobnoustrojów","parameters":[],"technique":"Metoda zminiaturyzowana (NPL)","techniques":["Metoda zminiaturyzowana (NPL)"],"computed":[],"activity":"Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda zminiaturyzowana (NPL)","reference":"Normy Ł","norm_bases":["Normy Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda zminiaturyzowana (NPL) Normy Ł Woda E, Woda do spozycia przez ludzi E Najbardziej prawdopodobna liczba drobnoustrojow\nMetoda zminiaturyzowana (NPL) Normy L","categories":["water","microbiology"],"row_index":322,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of microorganisms","search_en":"Water E, Water intended for human consumption E Most probable number of microorganisms Miniaturized method (MPN) Normy Ł","technique_en":"Miniaturized method (MPN)","test_object_en":"Water E, Water intended for human consumption E","search_zh":"水 E、生活饮用水 E 微生物最可能数 微量法（MPN） Normy Ł","technique_zh":"微量法（MPN）","test_object_zh":"水 E、生活饮用水 E","methodology_zh":"微生物最可能数"},{"_id":"6a82c6ff884ede9a1b2c2a8f","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Najbardziej prawdopodobna liczba drobnoustrojów","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda NPL","reference":"Normy | PB-02/LM Ł","norm_bases":["Normy","PB-02/LM Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda NPL Normy | PB-02/LM Ł Woda E, Woda do spozycia przez ludzi E Najbardziej prawdopodobna liczba drobnoustrojow\nMetoda NPL Normy | PB-02/LM L","categories":["water","microbiology"],"row_index":323,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of microorganisms","search_en":"Water E, Water intended for human consumption E Most probable number of microorganisms MPN method Normy | PB-02/LM Ł","technique_en":"MPN method","test_object_en":"Water E, Water intended for human consumption E","search_zh":"水 E、生活饮用水 E 微生物最可能数 最可能数法（MPN） Normy | PB-02/LM Ł","technique_zh":"最可能数法（MPN）","test_object_zh":"水 E、生活饮用水 E","methodology_zh":"微生物最可能数"},{"_id":"6a82c6ff884ede9a1b2c2a90","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Płyny do dializ, koncentraty do dializ, woda do dializ, woda ultraczysta E, Woda E, Woda do spożycia przez ludzi E","methodology":"Obecność endotoksyn bakteryjnych","parameters":[],"technique":"Metoda z zastosowaniem testu LAL","techniques":["Metoda z zastosowaniem testu LAL"],"computed":[],"activity":"Obecność endotoksyn bakteryjnych\nMetoda z zastosowaniem testu LAL","reference":"Farmakopea Polska Ł","norm_bases":["Farmakopea Polska Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Płyny do dializ, koncentraty do dializ, woda do dializ, woda ultraczysta E, Woda E, Woda do spożycia przez ludzi E Obecność endotoksyn bakteryjnych\nMetoda z zastosowaniem testu LAL Farmakopea Polska Ł Plyny do dializ, koncentraty do dializ, woda do dializ, woda ultraczysta E, Woda E, Woda do spozycia przez ludzi E Obecnosc endotoksyn bakteryjnych\nMetoda z zastosowaniem testu LAL Farmakopea Polska L","categories":["water"],"row_index":324,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of bacterial endotoxins","search_en":"Presence of bacterial endotoxins Method using the LAL test Farmakopea Polska Ł","technique_en":"Method using the LAL test","methodology_zh":"细菌内毒素的检出","search_zh":"细菌内毒素的检出 Farmakopea Polska Ł"},{"_id":"6a82c6ff884ede9a1b2c2a91","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Płyny do dializ, koncentraty do dializ, woda do dializ, woda ultraczysta E, Woda E, Woda do spożycia przez ludzi E","methodology":"Liczba drożdży i pleśni","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba drożdży i pleśni\nMetoda filtracji membranowej","reference":"Ł","norm_bases":["Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Płyny do dializ, koncentraty do dializ, woda do dializ, woda ultraczysta E, Woda E, Woda do spożycia przez ludzi E Liczba drożdży i pleśni\nMetoda filtracji membranowej Ł Plyny do dializ, koncentraty do dializ, woda do dializ, woda ultraczysta E, Woda E, Woda do spozycia przez ludzi E Liczba drozdzy i plesni\nMetoda filtracji membranowej L","categories":["water"],"row_index":325,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Yeast and mould count","search_en":"Yeast and mould count Membrane filtration method Ł","technique_en":"Membrane filtration method","methodology_zh":"酵母菌与霉菌计数","search_zh":"酵母菌与霉菌计数 膜过滤法 Ł","technique_zh":"膜过滤法"},{"_id":"6a82c6ff884ede9a1b2c2a92","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Płyny do dializ, koncentraty do dializ, woda do dializ, woda ultraczysta E, Woda E, Woda do spożycia przez ludzi E","methodology":"Liczba drożdży i pleśni","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drożdży i pleśni\nMetoda płytkowa (posiew wgłębny)","reference":"Ł","norm_bases":["Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Płyny do dializ, koncentraty do dializ, woda do dializ, woda ultraczysta E, Woda E, Woda do spożycia przez ludzi E Liczba drożdży i pleśni\nMetoda płytkowa (posiew wgłębny) Ł Plyny do dializ, koncentraty do dializ, woda do dializ, woda ultraczysta E, Woda E, Woda do spozycia przez ludzi E Liczba drozdzy i plesni\nMetoda plytkowa (posiew wglebny) L","categories":["water"],"row_index":326,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Yeast and mould count","search_en":"Yeast and mould count Plate method (pour plate) Ł","technique_en":"Plate method (pour plate)","methodology_zh":"酵母菌与霉菌计数","search_zh":"酵母菌与霉菌计数 平板法（倾注培养） Ł","technique_zh":"平板法（倾注培养）"},{"_id":"6a82c6ff884ede9a1b2c2a93","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Płyny do dializ, koncentraty do dializ, woda do dializ, woda ultraczysta E, Woda E, Woda do spożycia przez ludzi E","methodology":"Liczba bakterii mezofilnych / liczba drobnoustrojów tlenowych","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba bakterii mezofilnych / liczba drobnoustrojów tlenowych\nMetoda płytkowa (posiew wgłębny)","reference":"Ł","norm_bases":["Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Płyny do dializ, koncentraty do dializ, woda do dializ, woda ultraczysta E, Woda E, Woda do spożycia przez ludzi E Liczba bakterii mezofilnych / liczba drobnoustrojów tlenowych\nMetoda płytkowa (posiew wgłębny) Ł Plyny do dializ, koncentraty do dializ, woda do dializ, woda ultraczysta E, Woda E, Woda do spozycia przez ludzi E Liczba bakterii mezofilnych / liczba drobnoustrojow tlenowych\nMetoda plytkowa (posiew wglebny) L","categories":["microbiology","water"],"row_index":327,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of mesophilic bacteria / count of aerobic microorganisms","search_en":"Count of mesophilic bacteria / count of aerobic microorganisms Plate method (pour plate) Ł","technique_en":"Plate method (pour plate)","search_zh":"平板法（倾注培养） Ł","technique_zh":"平板法（倾注培养）"},{"_id":"6a82c6ff884ede9a1b2c2a94","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Płyny do dializ, koncentraty do dializ, woda do dializ, woda ultraczysta E, Woda E, Woda do spożycia przez ludzi E","methodology":"Liczba bakterii mezofilnych / liczba drobnoustrojów tlenowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii mezofilnych / liczba drobnoustrojów tlenowych\nMetoda filtracji membranowej","reference":"Ł","norm_bases":["Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Płyny do dializ, koncentraty do dializ, woda do dializ, woda ultraczysta E, Woda E, Woda do spożycia przez ludzi E Liczba bakterii mezofilnych / liczba drobnoustrojów tlenowych\nMetoda filtracji membranowej Ł Plyny do dializ, koncentraty do dializ, woda do dializ, woda ultraczysta E, Woda E, Woda do spozycia przez ludzi E Liczba bakterii mezofilnych / liczba drobnoustrojow tlenowych\nMetoda filtracji membranowej L","categories":["microbiology","water"],"row_index":328,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of mesophilic bacteria / count of aerobic microorganisms","search_en":"Count of mesophilic bacteria / count of aerobic microorganisms Membrane filtration method Ł","technique_en":"Membrane filtration method","search_zh":"膜过滤法 Ł","technique_zh":"膜过滤法"},{"_id":"6a82c6ff884ede9a1b2c2a95","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Powietrze E","methodology":"Ogólna liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa","techniques":["Metoda płytkowa"],"computed":[],"activity":"Ogólna liczba drobnoustrojów\nMetoda płytkowa","reference":"PB-05/LM Ł","norm_bases":["PB-05/LM Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Powietrze E Ogólna liczba drobnoustrojów\nMetoda płytkowa PB-05/LM Ł Powietrze E Ogolna liczba drobnoustrojow\nMetoda plytkowa PB-05/LM L","categories":["environment","microbiology"],"row_index":329,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count","search_en":"Air E Total viable count Plate method PB-05/LM Ł","technique_en":"Plate method","test_object_en":"Air E","methodology_zh":"微生物总数","search_zh":"空气 E 微生物总数 平板法 PB-05/LM Ł","technique_zh":"平板法","test_object_zh":"空气 E"},{"_id":"6a82c6ff884ede9a1b2c2a96","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Powietrze E","methodology":"Liczba bakterii tlenowych mezofilnych","parameters":[],"technique":"Metoda płytkowa","techniques":["Metoda płytkowa"],"computed":[],"activity":"Liczba bakterii tlenowych mezofilnych\nMetoda płytkowa","reference":"Ł","norm_bases":["Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Powietrze E Liczba bakterii tlenowych mezofilnych\nMetoda płytkowa Ł Powietrze E Liczba bakterii tlenowych mezofilnych\nMetoda plytkowa L","categories":["environment","microbiology"],"row_index":330,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Aerobic mesophilic bacteria count","search_en":"Air E Aerobic mesophilic bacteria count Plate method Ł","technique_en":"Plate method","test_object_en":"Air E","search_zh":"空气 E 嗜温需氧菌数 平板法 Ł","technique_zh":"平板法","test_object_zh":"空气 E","methodology_zh":"嗜温需氧菌数"},{"_id":"6a82c6ff884ede9a1b2c2a97","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Powietrze E","methodology":"Liczba drożdży i pleśni","parameters":[],"technique":"Metoda płytkowa","techniques":["Metoda płytkowa"],"computed":[],"activity":"Liczba drożdży i pleśni\nMetoda płytkowa","reference":"Ł","norm_bases":["Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Powietrze E Liczba drożdży i pleśni\nMetoda płytkowa Ł Powietrze E Liczba drozdzy i plesni\nMetoda plytkowa L","categories":["environment"],"row_index":331,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Yeast and mould count","search_en":"Air E Yeast and mould count Plate method Ł","technique_en":"Plate method","test_object_en":"Air E","methodology_zh":"酵母菌与霉菌计数","search_zh":"空气 E 酵母菌与霉菌计数 平板法 Ł","technique_zh":"平板法","test_object_zh":"空气 E"},{"_id":"6a82c6ff884ede9a1b2c2a98","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Pasze E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E","methodology":"Obecność specyficznego DNA drobnoustrojów","parameters":[],"technique":"Metoda real-time PCR","techniques":["Metoda real-time PCR"],"computed":[],"activity":"Obecność specyficznego DNA drobnoustrojów\nMetoda real-time PCR","reference":"Procedury badawcze Ł","norm_bases":["Procedury badawcze Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E Obecność specyficznego DNA drobnoustrojów\nMetoda real-time PCR Procedury badawcze Ł Zywnosc E, Pasze E, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia oraz z obszarow niezwiazanych z zywnoscia E Obecnosc specyficznego DNA drobnoustrojow\nMetoda real-time PCR Procedury badawcze L","categories":["food","environment","microbiology"],"row_index":332,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Real-time PCR method Procedury badawcze Ł","technique_en":"Real-time PCR method","search_zh":"实时荧光 PCR 法 Procedury badawcze Ł","technique_zh":"实时荧光 PCR 法"},{"_id":"6a82c6ff884ede9a1b2c2a99","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Dodatki do żywności E, Pasze E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem: - biochemicznym - biochemicznym i serologicznym - serologicznym","techniques":["Metoda hodowlana z potwierdzeniem: - biochemicznym - biochemicznym i serologicznym - serologicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem: - biochemicznym - biochemicznym i serologicznym - serologicznym","reference":"Procedury badawcze Normy Ł","norm_bases":["Procedury badawcze Normy Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Dodatki do żywności E, Pasze E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem: - biochemicznym - biochemicznym i serologicznym - serologicznym Procedury badawcze Normy Ł Zywnosc E, Dodatki do zywnosci E, Pasze E, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia oraz z obszarow niezwiazanych z zywnoscia E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem: - biochemicznym - biochemicznym i serologicznym - serologicznym Procedury badawcze Normy L","categories":["food","environment","microbiology"],"row_index":333,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of microorganisms","search_en":"Presence of microorganisms Culture method with confirmation: - biochemical - biochemical and serological - serological Procedury badawcze Normy Ł","technique_en":"Culture method with confirmation: - biochemical - biochemical and serological - serological","methodology_zh":"微生物的检出","search_zh":"微生物的检出 Procedury badawcze Normy Ł"},{"_id":"6a82c6ff884ede9a1b2c2a9a","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana","techniques":["Metoda hodowlana"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana","reference":"Procedury badawcze Ł","norm_bases":["Procedury badawcze Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Obecność drobnoustrojów\nMetoda hodowlana Procedury badawcze Ł Zywnosc E Obecnosc drobnoustrojow\nMetoda hodowlana Procedury badawcze L","categories":["food","microbiology"],"row_index":334,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of microorganisms","search_en":"Food E Presence of microorganisms Culture method Procedury badawcze Ł","technique_en":"Culture method","test_object_en":"Food E","search_zh":"食品 E 微生物的检出 培养法 Procedury badawcze Ł","technique_zh":"培养法","test_object_zh":"食品 E","methodology_zh":"微生物的检出"},{"_id":"6a82c6ff884ede9a1b2c2a9b","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Dodatki do żywności E, Pasze E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E, Tusze E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny i powierzchniowy)","techniques":["Metoda płytkowa (posiew wgłębny i powierzchniowy)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny i powierzchniowy)","reference":"Procedury badawcze Normy Ł","norm_bases":["Procedury badawcze Normy Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Dodatki do żywności E, Pasze E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E, Tusze E Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny i powierzchniowy) Procedury badawcze Normy Ł Zywnosc E, Dodatki do zywnosci E, Pasze E, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia oraz z obszarow niezwiazanych z zywnoscia E, Tusze E Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny i powierzchniowy) Procedury badawcze Normy L","categories":["food","environment","microbiology"],"row_index":335,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Microorganism count Plate method (pour plate and spread plate) Procedury badawcze Normy Ł","technique_en":"Plate method (pour plate and spread plate)","methodology_zh":"菌落总数","search_zh":"菌落总数 平板法（倾注平板与表面涂布） Procedury badawcze Normy Ł","technique_zh":"平板法（倾注平板与表面涂布）"},{"_id":"6a82c6ff884ede9a1b2c2a9c","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Pasze E, Dodatki do żywności E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (Easy Plate)","techniques":["Metoda płytkowa (Easy Plate)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (Easy Plate)","reference":"Instrukcje producenta Ł","norm_bases":["Instrukcje producenta Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E, Dodatki do żywności E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E Liczba drobnoustrojów\nMetoda płytkowa (Easy Plate) Instrukcje producenta Ł Zywnosc E, Pasze E, Dodatki do zywnosci E, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia oraz z obszarow niezwiazanych z zywnoscia E Liczba drobnoustrojow\nMetoda plytkowa (Easy Plate) Instrukcje producenta L","categories":["food","environment","microbiology"],"row_index":336,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Microorganism count Instrukcje producenta Ł","methodology_zh":"菌落总数","search_zh":"菌落总数 Instrukcje producenta Ł"},{"_id":"6a82c6ff884ede9a1b2c2a9d","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji pierwotnej E - wymazy","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"Normy Ł","norm_bases":["Normy Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji pierwotnej E - wymazy Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy Ł Probki srodowiskowe z obszarow produkcji pierwotnej E - wymazy Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy L","categories":["environment","microbiology"],"row_index":337,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of microorganisms","search_en":"Presence of microorganisms Culture method with biochemical and serological confirmation Normy Ł","technique_en":"Culture method with biochemical and serological confirmation","search_zh":"微生物的检出 培养法结合生化与血清学确认 Normy Ł","technique_zh":"培养法结合生化与血清学确认","methodology_zh":"微生物的检出"},{"_id":"6a82c6ff884ede9a1b2c2a9e","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji pierwotnej E - wymazy","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Normy Ł","norm_bases":["Normy Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji pierwotnej E - wymazy Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Normy Ł Probki srodowiskowe z obszarow produkcji pierwotnej E - wymazy Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Normy L","categories":["environment","microbiology"],"row_index":338,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Microorganism count Plate method (pour plate) Normy Ł","technique_en":"Plate method (pour plate)","methodology_zh":"菌落总数","search_zh":"菌落总数 平板法（倾注培养） Normy Ł","technique_zh":"平板法（倾注培养）"},{"_id":"6a82c6ff884ede9a1b2c2a9f","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji pierwotnej E - wymazy","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy)","reference":"Normy Ł","norm_bases":["Normy Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji pierwotnej E - wymazy Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy) Normy Ł Probki srodowiskowe z obszarow produkcji pierwotnej E - wymazy Liczba drobnoustrojow\nMetoda plytkowa (posiew powierzchniowy) Normy L","categories":["environment","microbiology"],"row_index":339,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Microorganism count Plate method (spread plate) Normy Ł","technique_en":"Plate method (spread plate)","methodology_zh":"菌落总数","search_zh":"菌落总数 平板法（表面涂布） Normy Ł","technique_zh":"平板法（表面涂布）"},{"_id":"6a82c6ff884ede9a1b2c2aa0","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Najbardziej prawdopodobna liczba drobnoustrojów","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda NPL","reference":"Normy Ł","norm_bases":["Normy Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda NPL Normy Ł Zywnosc E, Pasze E Najbardziej prawdopodobna liczba drobnoustrojow\nMetoda NPL Normy L","categories":["food","microbiology"],"row_index":340,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of microorganisms","search_en":"Food E, Feed E Most probable number of microorganisms MPN method Normy Ł","technique_en":"MPN method","test_object_en":"Food E, Feed E","search_zh":"食品 E、饲料 E 微生物最可能数 最可能数法（MPN） Normy Ł","technique_zh":"最可能数法（MPN）","methodology_zh":"微生物最可能数","test_object_zh":"食品 E、饲料 E"},{"_id":"6a82c6ff884ede9a1b2c2aa1","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Najbardziej prawdopodobna liczba drobnoustrojów","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda NPL","reference":"Procedury badawcze Ł","norm_bases":["Procedury badawcze Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda NPL Procedury badawcze Ł Zywnosc E, Pasze E Najbardziej prawdopodobna liczba drobnoustrojow\nMetoda NPL Procedury badawcze L","categories":["food","microbiology"],"row_index":341,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of microorganisms","search_en":"Food E, Feed E Most probable number of microorganisms MPN method Procedury badawcze Ł","technique_en":"MPN method","test_object_en":"Food E, Feed E","search_zh":"食品 E、饲料 E 微生物最可能数 最可能数法（MPN） Procedury badawcze Ł","technique_zh":"最可能数法（MPN）","methodology_zh":"微生物最可能数","test_object_zh":"食品 E、饲料 E"},{"_id":"6a82c6ff884ede9a1b2c2aa2","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Obecność specyficznej sekwencji dla, GMO","parameters":[],"technique":"Metoda real-time PCR","techniques":["Metoda real-time PCR"],"computed":[],"activity":"Obecność specyficznej sekwencji dla, GMO\nMetoda real-time PCR","reference":"PB-27/LM Ł","norm_bases":["PB-27/LM Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E Obecność specyficznej sekwencji dla, GMO\nMetoda real-time PCR PB-27/LM Ł Zywnosc E, Pasze E Obecnosc specyficznej sekwencji dla, GMO\nMetoda real-time PCR PB-27/LM L","categories":["food"],"row_index":342,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Food E, Feed E Real-time PCR method PB-27/LM Ł","technique_en":"Real-time PCR method","test_object_en":"Food E, Feed E","search_zh":"食品 E、饲料 E 实时荧光 PCR 法 PB-27/LM Ł","technique_zh":"实时荧光 PCR 法","test_object_zh":"食品 E、饲料 E"},{"_id":"6a82c6ff884ede9a1b2c2aa3","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E","methodology":"Obecność specyficznego DNA dla alergenu","parameters":[],"technique":"Metoda real-time PCR","techniques":["Metoda real-time PCR"],"computed":[],"activity":"Obecność specyficznego DNA dla alergenu\nMetoda real-time PCR","reference":"PB-22/LM Ł","norm_bases":["PB-22/LM Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E Obecność specyficznego DNA dla alergenu\nMetoda real-time PCR PB-22/LM Ł Zywnosc E, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia E Obecnosc specyficznego DNA dla alergenu\nMetoda real-time PCR PB-22/LM L","categories":["food","environment"],"row_index":343,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Food E, Environmental samples from food production and food trade areas E Real-time PCR method PB-22/LM Ł","technique_en":"Real-time PCR method","test_object_en":"Food E, Environmental samples from food production and food trade areas E","search_zh":"食品 E、来自食品生产与流通场所的环境样品 E 实时荧光 PCR 法 PB-22/LM Ł","technique_zh":"实时荧光 PCR 法","test_object_zh":"食品 E、来自食品生产与流通场所的环境样品 E"},{"_id":"6a82c6ff884ede9a1b2c2aa4","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Woda butelkowana E","methodology":"Obecność specyficznego RNA materiału genetycznego wirusów","parameters":[],"technique":"Metoda real-time PCR","techniques":["Metoda real-time PCR"],"computed":[],"activity":"Obecność specyficznego RNA materiału genetycznego wirusów\nMetoda real-time PCR","reference":"Normy Instrukcje producenta Ł","norm_bases":["Normy Instrukcje producenta Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Woda butelkowana E Obecność specyficznego RNA materiału genetycznego wirusów\nMetoda real-time PCR Normy Instrukcje producenta Ł Zywnosc E, Woda butelkowana E Obecnosc specyficznego RNA materialu genetycznego wirusow\nMetoda real-time PCR Normy Instrukcje producenta L","categories":["water","food","materials"],"row_index":344,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Real-time PCR method Normy Instrukcje producenta Ł","technique_en":"Real-time PCR method","search_zh":"实时荧光 PCR 法 Normy Instrukcje producenta Ł","technique_zh":"实时荧光 PCR 法"},{"_id":"6a82c6ff884ede9a1b2c2aa5","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność Escherichia coli wytwarzających toksynę Shiga (STEC) oraz identyfikacja serogrup O103, O157, O111, O26, O145, O121, O45, O104","parameters":[],"technique":"Metoda real-time PCR","techniques":["Metoda real-time PCR"],"computed":[],"activity":"Obecność Escherichia coli wytwarzających toksynę Shiga (STEC) oraz identyfikacja serogrup O103, O157, O111, O26, O145, O121, O45, O104\nMetoda real-time PCR","reference":"ISO 13136 Instrukcje producenta Ł","norm_bases":["ISO 13136 Instrukcje producenta Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Obecność Escherichia coli wytwarzających toksynę Shiga (STEC) oraz identyfikacja serogrup O103, O157, O111, O26, O145, O121, O45, O104\nMetoda real-time PCR ISO 13136 Instrukcje producenta Ł Zywnosc E Obecnosc Escherichia coli wytwarzajacych toksyne Shiga (STEC) oraz identyfikacja serogrup O103, O157, O111, O26, O145, O121, O45, O104\nMetoda real-time PCR ISO 13136 Instrukcje producenta L","categories":["food","microbiology"],"row_index":345,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Shiga toxin-producing Escherichia coli (STEC) and identification of serogroups O103, O157, O111, O26, O145, O121, O45, O104","search_en":"Food E Presence of Shiga toxin-producing Escherichia coli (STEC) and identification of serogroups O103, O157, O111, O26, O145, O121, O45, O104 Real-time PCR method ISO 13136 Instrukcje producenta Ł","technique_en":"Real-time PCR method","test_object_en":"Food E","search_zh":"食品 E 实时荧光 PCR 法 ISO 13136 Instrukcje producenta Ł","test_object_zh":"食品 E","technique_zh":"实时荧光 PCR 法"},{"_id":"6a82c6ff884ede9a1b2c2aa6","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Zawartość witaminy","parameters":[],"technique":"Metoda mikropłytkowa z odczytem spektrofotometrycznym","techniques":["Metoda mikropłytkowa z odczytem spektrofotometrycznym"],"computed":[],"activity":"Zawartość witaminy\nMetoda mikropłytkowa z odczytem spektrofotometrycznym","reference":"Instrukcje producenta Ł","norm_bases":["Instrukcje producenta Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E Zawartość witaminy\nMetoda mikropłytkowa z odczytem spektrofotometrycznym Instrukcje producenta Ł Zywnosc E, Pasze E Zawartosc witaminy\nMetoda mikroplytkowa z odczytem spektrofotometrycznym Instrukcje producenta L","categories":["food"],"row_index":346,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Food E, Feed E Microplate method with spectrophotometric reading Instrukcje producenta Ł","technique_en":"Microplate method with spectrophotometric reading","test_object_en":"Food E, Feed E","search_zh":"食品 E、饲料 E 微孔板法附分光光度读数 Instrukcje producenta Ł","test_object_zh":"食品 E、饲料 E","technique_zh":"微孔板法附分光光度读数"},{"_id":"6a82c6ff884ede9a1b2c2aa7","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E","methodology":"Liczba drożdży i pleśni","parameters":[],"technique":"Metoda płytek kontaktowych","techniques":["Metoda płytek kontaktowych"],"computed":[],"activity":"Liczba drożdży i pleśni\nMetoda płytek kontaktowych","reference":"PB-89/LM Ł","norm_bases":["PB-89/LM Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E Liczba drożdży i pleśni\nMetoda płytek kontaktowych PB-89/LM Ł Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia oraz z obszarow niezwiazanych z zywnoscia E Liczba drozdzy i plesni\nMetoda plytek kontaktowych PB-89/LM L","categories":["food","environment"],"row_index":347,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Yeast and mould count","search_en":"Yeast and mould count Contact plate method PB-89/LM Ł","technique_en":"Contact plate method","methodology_zh":"酵母菌与霉菌计数","search_zh":"酵母菌与霉菌计数 接触平皿法 PB-89/LM Ł","technique_zh":"接触平皿法"},{"_id":"6a82c6ff884ede9a1b2c2aa8","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E","methodology":"Liczba Enterobacteriaceae","parameters":[],"technique":"Metoda płytek kontaktowych","techniques":["Metoda płytek kontaktowych"],"computed":[],"activity":"Liczba Enterobacteriaceae\nMetoda płytek kontaktowych","reference":"Ł","norm_bases":["Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E Liczba Enterobacteriaceae\nMetoda płytek kontaktowych Ł Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia oraz z obszarow niezwiazanych z zywnoscia E Liczba Enterobacteriaceae\nMetoda plytek kontaktowych L","categories":["food","environment"],"row_index":348,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Enterobacteriaceae count","search_en":"Enterobacteriaceae count Contact plate method Ł","technique_en":"Contact plate method","methodology_zh":"肠杆菌科（Enterobacteriaceae）计数","search_zh":"肠杆菌科（Enterobacteriaceae）计数 接触平皿法 Ł","technique_zh":"接触平皿法"},{"_id":"6a82c6ff884ede9a1b2c2aa9","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E","methodology":"Ogólna liczba drobnoustrojów","parameters":[],"technique":"Metoda płytek kontaktowych","techniques":["Metoda płytek kontaktowych"],"computed":[],"activity":"Ogólna liczba drobnoustrojów\nMetoda płytek kontaktowych","reference":"Ł","norm_bases":["Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E Ogólna liczba drobnoustrojów\nMetoda płytek kontaktowych Ł Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia oraz z obszarow niezwiazanych z zywnoscia E Ogolna liczba drobnoustrojow\nMetoda plytek kontaktowych L","categories":["food","environment","microbiology"],"row_index":349,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count","search_en":"Total viable count Contact plate method Ł","technique_en":"Contact plate method","methodology_zh":"微生物总数","search_zh":"微生物总数 接触平皿法 Ł","technique_zh":"接触平皿法"},{"_id":"6a82c6ff884ede9a1b2c2aaa","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Kosmetyki, surowce i półprodukty do produkcji kosmetyków, chemia gospodarcza, artykuły higieniczne E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Normy Ł","norm_bases":["Normy Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Kosmetyki, surowce i półprodukty do produkcji kosmetyków, chemia gospodarcza, artykuły higieniczne E Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Normy Ł Kosmetyki, surowce i polprodukty do produkcji kosmetykow, chemia gospodarcza, artykuly higieniczne E Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Normy L","categories":["microbiology","pharma"],"row_index":350,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Microorganism count Plate method (pour plate) Normy Ł","technique_en":"Plate method (pour plate)","methodology_zh":"菌落总数","search_zh":"菌落总数 平板法（倾注培养） Normy Ł","technique_zh":"平板法（倾注培养）"},{"_id":"6a82c6ff884ede9a1b2c2aab","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Kosmetyki, surowce i półprodukty do produkcji kosmetyków, chemia gospodarcza, artykuły higieniczne E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana; Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana","Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana; Metoda hodowlana z potwierdzeniem biochemicznym","reference":"Normy Ł","norm_bases":["Normy Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Kosmetyki, surowce i półprodukty do produkcji kosmetyków, chemia gospodarcza, artykuły higieniczne E Obecność drobnoustrojów\nMetoda hodowlana; Metoda hodowlana z potwierdzeniem biochemicznym Normy Ł Kosmetyki, surowce i polprodukty do produkcji kosmetykow, chemia gospodarcza, artykuly higieniczne E Obecnosc drobnoustrojow\nMetoda hodowlana; Metoda hodowlana z potwierdzeniem biochemicznym Normy L","categories":["microbiology","pharma"],"row_index":351,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of microorganisms","search_en":"Presence of microorganisms Culture method; Culture method with biochemical confirmation Normy Ł","technique_en":"Culture method; Culture method with biochemical confirmation","methodology_zh":"微生物的检出","search_zh":"微生物的检出 Normy Ł"},{"_id":"6a82c6ff884ede9a1b2c2aac","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Kosmetyki E, Wyroby farmaceutyczne E","methodology":"Skuteczność zakonserwowania – test konserwacji","parameters":[],"technique":"Metoda płytkowa","techniques":["Metoda płytkowa"],"computed":[],"activity":"Skuteczność zakonserwowania – test konserwacji\nMetoda płytkowa","reference":"Normy Farmakopea Polska Ł","norm_bases":["Normy Farmakopea Polska Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Kosmetyki E, Wyroby farmaceutyczne E Skuteczność zakonserwowania – test konserwacji\nMetoda płytkowa Normy Farmakopea Polska Ł Kosmetyki E, Wyroby farmaceutyczne E Skutecznosc zakonserwowania – test konserwacji\nMetoda plytkowa Normy Farmakopea Polska L","categories":["pharma"],"row_index":352,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Preservation efficacy – preservation test","search_en":"Preservation efficacy – preservation test Plate method Normy Farmakopea Polska Ł","technique_en":"Plate method","search_zh":"平板法 Normy Farmakopea Polska Ł","technique_zh":"平板法"},{"_id":"6a82c6ff884ede9a1b2c2aad","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Chemiczne środki dezynfekcyjne i antyseptyczne E","methodology":"Skuteczność działania biobójczego","parameters":[],"technique":"Metoda zawiesinowa","techniques":["Metoda zawiesinowa"],"computed":[],"activity":"Skuteczność działania biobójczego\nMetoda zawiesinowa","reference":"Normy Ł","norm_bases":["Normy Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Chemiczne środki dezynfekcyjne i antyseptyczne E Skuteczność działania biobójczego\nMetoda zawiesinowa Normy Ł Chemiczne srodki dezynfekcyjne i antyseptyczne E Skutecznosc dzialania biobojczego\nMetoda zawiesinowa Normy L","categories":["other"],"row_index":353,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Chemical disinfectants and antiseptics E Suspension method Normy Ł","technique_en":"Suspension method","test_object_en":"Chemical disinfectants and antiseptics E","search_zh":"化学消毒剂与防腐剂 E Normy Ł","test_object_zh":"化学消毒剂与防腐剂 E"},{"_id":"6a82c6ff884ede9a1b2c2aae","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Chemiczne środki dezynfekcyjne i antyseptyczne E","methodology":"Skuteczność działania biobójczego na powierzchniach nieporowatych","parameters":[],"technique":"Metoda płytkowa","techniques":["Metoda płytkowa"],"computed":[],"activity":"Skuteczność działania biobójczego na powierzchniach nieporowatych\nMetoda płytkowa","reference":"Normy Ł","norm_bases":["Normy Ł"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Chemiczne środki dezynfekcyjne i antyseptyczne E Skuteczność działania biobójczego na powierzchniach nieporowatych\nMetoda płytkowa Normy Ł Chemiczne srodki dezynfekcyjne i antyseptyczne E Skutecznosc dzialania biobojczego na powierzchniach nieporowatych\nMetoda plytkowa Normy L","categories":["other"],"row_index":354,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Chemical disinfectants and antiseptics E Plate method Normy Ł","technique_en":"Plate method","test_object_en":"Chemical disinfectants and antiseptics E","search_zh":"化学消毒剂与防腐剂 E 平板法 Normy Ł","technique_zh":"平板法","test_object_zh":"化学消毒剂与防腐剂 E"},{"_id":"6a82c6ff884ede9a1b2c2aaf","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E, Koncentrat do dializ, płyn do dializ, woda do dializ E","methodology":"Liczba bakterii mezofilnych","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba bakterii mezofilnych\nMetoda płytkowa (posiew wgłębny)","reference":"PB-01/LM P","norm_bases":["PB-01/LM P"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E, Koncentrat do dializ, płyn do dializ, woda do dializ E Liczba bakterii mezofilnych\nMetoda płytkowa (posiew wgłębny) PB-01/LM P Woda E, Woda do spozycia przez ludzi E, Koncentrat do dializ, plyn do dializ, woda do dializ E Liczba bakterii mezofilnych\nMetoda plytkowa (posiew wglebny) PB-01/LM P","categories":["water","microbiology"],"row_index":355,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of mesophilic bacteria","search_en":"Count of mesophilic bacteria Plate method (pour plate) PB-01/LM P","technique_en":"Plate method (pour plate)","search_zh":"平板法（倾注培养） PB-01/LM P","technique_zh":"平板法（倾注培养）"},{"_id":"6a82c6ff884ede9a1b2c2ab0","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E, Koncentrat do dializ, płyn do dializ, woda do dializ E","methodology":"Liczba bakterii psychrofilnych","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba bakterii psychrofilnych\nMetoda płytkowa (posiew wgłębny)","reference":"PB-01/LM P","norm_bases":["PB-01/LM P"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E, Koncentrat do dializ, płyn do dializ, woda do dializ E Liczba bakterii psychrofilnych\nMetoda płytkowa (posiew wgłębny) PB-01/LM P Woda E, Woda do spozycia przez ludzi E, Koncentrat do dializ, plyn do dializ, woda do dializ E Liczba bakterii psychrofilnych\nMetoda plytkowa (posiew wglebny) PB-01/LM P","categories":["water","microbiology"],"row_index":356,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of psychrophilic bacteria","search_en":"Count of psychrophilic bacteria Plate method (pour plate) PB-01/LM P","technique_en":"Plate method (pour plate)","search_zh":"平板法（倾注培养） PB-01/LM P","technique_zh":"平板法（倾注培养）"},{"_id":"6a82c6ff884ede9a1b2c2ab1","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Koncentrat do dializ, płyn do dializ, woda do dializ E","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266 P","norm_bases":["PN-EN ISO 16266 P"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Koncentrat do dializ, płyn do dializ, woda do dializ E Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266 P Koncentrat do dializ, plyn do dializ, woda do dializ E Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266 P","categories":["water"],"row_index":357,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pseudomonas aeruginosa count","search_en":"Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266 P","technique_en":"Membrane filtration method","methodology_zh":"铜绿假单胞菌计数","search_zh":"铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266 P","technique_zh":"膜过滤法"},{"_id":"6a82c6ff884ede9a1b2c2ab2","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda filtracji membranowej","reference":"Normy P","norm_bases":["Normy P"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Liczba drobnoustrojów\nMetoda filtracji membranowej Normy P Woda E, Woda do spozycia przez ludzi E Liczba drobnoustrojow\nMetoda filtracji membranowej Normy P","categories":["water","microbiology"],"row_index":358,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Water E, Water intended for human consumption E Microorganism count Membrane filtration method Normy P","technique_en":"Membrane filtration method","test_object_en":"Water E, Water intended for human consumption E","methodology_zh":"菌落总数","search_zh":"水 E、生活饮用水 E 菌落总数 膜过滤法 Normy P","technique_zh":"膜过滤法","test_object_zh":"水 E、生活饮用水 E"},{"_id":"6a82c6ff884ede9a1b2c2ab3","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Normy P","norm_bases":["Normy P"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Normy P Woda E, Woda do spozycia przez ludzi E Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Normy P","categories":["water","microbiology"],"row_index":359,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Water E, Water intended for human consumption E Microorganism count Plate method (pour plate) Normy P","technique_en":"Plate method (pour plate)","test_object_en":"Water E, Water intended for human consumption E","methodology_zh":"菌落总数","search_zh":"水 E、生活饮用水 E 菌落总数 平板法（倾注培养） Normy P","technique_zh":"平板法（倾注培养）","test_object_zh":"水 E、生活饮用水 E"},{"_id":"6a82c6ff884ede9a1b2c2ab4","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E, Koncentrat do dializ, płyn do dializ, woda do dializ, woda ultraczysta E","methodology":"Obecność endotoksyn bakteryjnych","parameters":[],"technique":"Metoda z zastosowaniem testu LAL","techniques":["Metoda z zastosowaniem testu LAL"],"computed":[],"activity":"Obecność endotoksyn bakteryjnych\nMetoda z zastosowaniem testu LAL","reference":"Farmakopea Polska P","norm_bases":["Farmakopea Polska P"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E, Koncentrat do dializ, płyn do dializ, woda do dializ, woda ultraczysta E Obecność endotoksyn bakteryjnych\nMetoda z zastosowaniem testu LAL Farmakopea Polska P Woda E, Woda do spozycia przez ludzi E, Koncentrat do dializ, plyn do dializ, woda do dializ, woda ultraczysta E Obecnosc endotoksyn bakteryjnych\nMetoda z zastosowaniem testu LAL Farmakopea Polska P","categories":["water"],"row_index":360,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of bacterial endotoxins","search_en":"Presence of bacterial endotoxins Method using the LAL test Farmakopea Polska P","technique_en":"Method using the LAL test","methodology_zh":"细菌内毒素的检出","search_zh":"细菌内毒素的检出 Farmakopea Polska P"},{"_id":"6a82c6ff884ede9a1b2c2ab5","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E, Koncentrat do dializ, płyn do dializ, woda do dializ, woda ultraczysta E","methodology":"Liczba drożdży i pleśni","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba drożdży i pleśni\nMetoda filtracji membranowej","reference":"Farmakopea Polska P","norm_bases":["Farmakopea Polska P"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E, Koncentrat do dializ, płyn do dializ, woda do dializ, woda ultraczysta E Liczba drożdży i pleśni\nMetoda filtracji membranowej Farmakopea Polska P Woda E, Woda do spozycia przez ludzi E, Koncentrat do dializ, plyn do dializ, woda do dializ, woda ultraczysta E Liczba drozdzy i plesni\nMetoda filtracji membranowej Farmakopea Polska P","categories":["water"],"row_index":361,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Yeast and mould count","search_en":"Yeast and mould count Membrane filtration method Farmakopea Polska P","technique_en":"Membrane filtration method","methodology_zh":"酵母菌与霉菌计数","search_zh":"酵母菌与霉菌计数 膜过滤法 Farmakopea Polska P","technique_zh":"膜过滤法"},{"_id":"6a82c6ff884ede9a1b2c2ab6","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E, Koncentrat do dializ, płyn do dializ, woda do dializ, woda ultraczysta E","methodology":"Liczba drożdży i pleśni","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drożdży i pleśni\nMetoda płytkowa (posiew wgłębny)","reference":"Farmakopea Polska P","norm_bases":["Farmakopea Polska P"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E, Koncentrat do dializ, płyn do dializ, woda do dializ, woda ultraczysta E Liczba drożdży i pleśni\nMetoda płytkowa (posiew wgłębny) Farmakopea Polska P Woda E, Woda do spozycia przez ludzi E, Koncentrat do dializ, plyn do dializ, woda do dializ, woda ultraczysta E Liczba drozdzy i plesni\nMetoda plytkowa (posiew wglebny) Farmakopea Polska P","categories":["water"],"row_index":362,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Yeast and mould count","search_en":"Yeast and mould count Plate method (pour plate) Farmakopea Polska P","technique_en":"Plate method (pour plate)","methodology_zh":"酵母菌与霉菌计数","search_zh":"酵母菌与霉菌计数 平板法（倾注培养） Farmakopea Polska P","technique_zh":"平板法（倾注培养）"},{"_id":"6a82c6ff884ede9a1b2c2ab7","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E, Koncentrat do dializ, płyn do dializ, woda do dializ, woda ultraczysta E","methodology":"Liczba bakterii mezofilnych/liczba drobnoustrojów tlenowych","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba bakterii mezofilnych/liczba drobnoustrojów tlenowych\nMetoda płytkowa (posiew wgłębny)","reference":"Farmakopea Polska P","norm_bases":["Farmakopea Polska P"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E, Koncentrat do dializ, płyn do dializ, woda do dializ, woda ultraczysta E Liczba bakterii mezofilnych/liczba drobnoustrojów tlenowych\nMetoda płytkowa (posiew wgłębny) Farmakopea Polska P Woda E, Woda do spozycia przez ludzi E, Koncentrat do dializ, plyn do dializ, woda do dializ, woda ultraczysta E Liczba bakterii mezofilnych/liczba drobnoustrojow tlenowych\nMetoda plytkowa (posiew wglebny) Farmakopea Polska P","categories":["microbiology","water"],"row_index":363,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of mesophilic bacteria/count of aerobic microorganisms","search_en":"Count of mesophilic bacteria/count of aerobic microorganisms Plate method (pour plate) Farmakopea Polska P","technique_en":"Plate method (pour plate)","search_zh":"平板法（倾注培养） Farmakopea Polska P","technique_zh":"平板法（倾注培养）"},{"_id":"6a82c6ff884ede9a1b2c2ab8","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E, Koncentrat do dializ, płyn do dializ, woda do dializ, woda ultraczysta E","methodology":"Liczba bakterii mezofilnych/liczba drobnoustrojów tlenowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii mezofilnych/liczba drobnoustrojów tlenowych\nMetoda filtracji membranowej","reference":"Farmakopea Polska P","norm_bases":["Farmakopea Polska P"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E, Koncentrat do dializ, płyn do dializ, woda do dializ, woda ultraczysta E Liczba bakterii mezofilnych/liczba drobnoustrojów tlenowych\nMetoda filtracji membranowej Farmakopea Polska P Woda E, Woda do spozycia przez ludzi E, Koncentrat do dializ, plyn do dializ, woda do dializ, woda ultraczysta E Liczba bakterii mezofilnych/liczba drobnoustrojow tlenowych\nMetoda filtracji membranowej Farmakopea Polska P","categories":["microbiology","water"],"row_index":364,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of mesophilic bacteria/count of aerobic microorganisms","search_en":"Count of mesophilic bacteria/count of aerobic microorganisms Membrane filtration method Farmakopea Polska P","technique_en":"Membrane filtration method","search_zh":"膜过滤法 Farmakopea Polska P","technique_zh":"膜过滤法"},{"_id":"6a82c6ff884ede9a1b2c2ab9","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda powierzchniowa , w tym woda z kąpielisk E","methodology":"Najbardziej prawdopodobna liczba, Escherichia coli","parameters":[],"technique":"Metoda zminiaturyzowana (NPL)","techniques":["Metoda zminiaturyzowana (NPL)"],"computed":[],"activity":"Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda zminiaturyzowana (NPL)","reference":"Normy P","norm_bases":["Normy P"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda powierzchniowa , w tym woda z kąpielisk E Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda zminiaturyzowana (NPL) Normy P Woda powierzchniowa , w tym woda z kapielisk E Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda zminiaturyzowana (NPL) Normy P","categories":["water","microbiology"],"row_index":365,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number, Escherichia coli","search_en":"Most probable number, Escherichia coli Miniaturized method (MPN) Normy P","technique_en":"Miniaturized method (MPN)","methodology_zh":"大肠埃希氏菌（Escherichia coli）最可能数（MPN）","search_zh":"大肠埃希氏菌（Escherichia coli）最可能数（MPN） 微量法（MPN） Normy P","technique_zh":"微量法（MPN）"},{"_id":"6a82c6ff884ede9a1b2c2aba","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda powierzchniowa , w tym woda z kąpielisk E","methodology":"Najbardziej prawdopodobna liczba enterokoków kałowych","parameters":[],"technique":"Metoda zminiaturyzowana (NPL)","techniques":["Metoda zminiaturyzowana (NPL)"],"computed":[],"activity":"Najbardziej prawdopodobna liczba enterokoków kałowych\nMetoda zminiaturyzowana (NPL)","reference":"Normy P","norm_bases":["Normy P"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda powierzchniowa , w tym woda z kąpielisk E Najbardziej prawdopodobna liczba enterokoków kałowych\nMetoda zminiaturyzowana (NPL) Normy P Woda powierzchniowa , w tym woda z kapielisk E Najbardziej prawdopodobna liczba enterokokow kalowych\nMetoda zminiaturyzowana (NPL) Normy P","categories":["water"],"row_index":366,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of intestinal enterococci","search_en":"Most probable number of intestinal enterococci Miniaturized method (MPN) Normy P","technique_en":"Miniaturized method (MPN)","search_zh":"粪肠球菌最可能数 微量法（MPN） Normy P","technique_zh":"微量法（MPN）","methodology_zh":"粪肠球菌最可能数"},{"_id":"6a82c6ff884ede9a1b2c2abb","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Powietrze E","methodology":"Ogólna liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa","techniques":["Metoda płytkowa"],"computed":[],"activity":"Ogólna liczba drobnoustrojów\nMetoda płytkowa","reference":"PB-05/LM P","norm_bases":["PB-05/LM P"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Powietrze E Ogólna liczba drobnoustrojów\nMetoda płytkowa PB-05/LM P Powietrze E Ogolna liczba drobnoustrojow\nMetoda plytkowa PB-05/LM P","categories":["environment","microbiology"],"row_index":367,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count","search_en":"Air E Total viable count Plate method PB-05/LM P","technique_en":"Plate method","test_object_en":"Air E","methodology_zh":"微生物总数","search_zh":"空气 E 微生物总数 平板法 PB-05/LM P","technique_zh":"平板法","test_object_zh":"空气 E"},{"_id":"6a82c6ff884ede9a1b2c2abc","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Powietrze E","methodology":"Liczba drożdży i pleśni","parameters":[],"technique":"Metoda płytkowa","techniques":["Metoda płytkowa"],"computed":[],"activity":"Liczba drożdży i pleśni\nMetoda płytkowa","reference":"PB-05/LM P","norm_bases":["PB-05/LM P"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Powietrze E Liczba drożdży i pleśni\nMetoda płytkowa PB-05/LM P Powietrze E Liczba drozdzy i plesni\nMetoda plytkowa PB-05/LM P","categories":["environment"],"row_index":368,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Yeast and mould count","search_en":"Air E Yeast and mould count Plate method PB-05/LM P","technique_en":"Plate method","test_object_en":"Air E","methodology_zh":"酵母菌与霉菌计数","search_zh":"空气 E 酵母菌与霉菌计数 平板法 PB-05/LM P","technique_zh":"平板法","test_object_zh":"空气 E"},{"_id":"6a82c6ff884ede9a1b2c2abd","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Pasze E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E","methodology":"Obecność specyficznego DNA drobnoustrojów","parameters":[],"technique":"Metoda real-time PCR","techniques":["Metoda real-time PCR"],"computed":[],"activity":"Obecność specyficznego DNA drobnoustrojów\nMetoda real-time PCR","reference":"Procedury badawcze P","norm_bases":["Procedury badawcze P"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E Obecność specyficznego DNA drobnoustrojów\nMetoda real-time PCR Procedury badawcze P Zywnosc E, Pasze E, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia E Obecnosc specyficznego DNA drobnoustrojow\nMetoda real-time PCR Procedury badawcze P","categories":["food","environment","microbiology"],"row_index":369,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Real-time PCR method Procedury badawcze P","technique_en":"Real-time PCR method","search_zh":"实时荧光 PCR 法 Procedury badawcze P","technique_zh":"实时荧光 PCR 法"},{"_id":"6a82c6ff884ede9a1b2c2abe","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Pasze E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"Procedury badawcze Normy P","norm_bases":["Procedury badawcze Normy P"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym Procedury badawcze Normy P Zywnosc E, Pasze E, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia oraz z obszarow niezwiazanych z zywnoscia E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym Procedury badawcze Normy P","categories":["food","environment","microbiology"],"row_index":370,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of microorganisms","search_en":"Presence of microorganisms Culture method with biochemical confirmation Procedury badawcze Normy P","technique_en":"Culture method with biochemical confirmation","search_zh":"微生物的检出 培养法结合生化确认 Procedury badawcze Normy P","technique_zh":"培养法结合生化确认","methodology_zh":"微生物的检出"},{"_id":"6a82c6ff884ede9a1b2c2abf","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Pasze E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"Normy","norm_bases":["Normy"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy Zywnosc E, Pasze E, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia oraz z obszarow niezwiazanych z zywnoscia E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy","categories":["food","environment","microbiology"],"row_index":371,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of microorganisms","search_en":"Presence of microorganisms Culture method with biochemical and serological confirmation Normy","technique_en":"Culture method with biochemical and serological confirmation","search_zh":"微生物的检出 培养法结合生化与血清学确认 Normy","technique_zh":"培养法结合生化与血清学确认","methodology_zh":"微生物的检出"},{"_id":"6a82c6ff884ede9a1b2c2ac0","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Pasze E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem serologicznym","techniques":["Metoda hodowlana z potwierdzeniem serologicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem serologicznym","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem serologicznym Procedury badawcze Zywnosc E, Pasze E, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia oraz z obszarow niezwiazanych z zywnoscia E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem serologicznym Procedury badawcze","categories":["food","environment","microbiology"],"row_index":372,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of microorganisms","search_en":"Presence of microorganisms Culture method with serological confirmation Procedury badawcze","technique_en":"Culture method with serological confirmation","methodology_zh":"微生物的检出","search_zh":"微生物的检出 Procedury badawcze"},{"_id":"6a82c6ff884ede9a1b2c2ac1","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E","methodology":"Obecność Campylobacter spp.","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym"],"computed":[],"activity":"Obecność Campylobacter spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym","reference":"PN -EN ISO 10272-1 P","norm_bases":["PN -EN ISO 10272-1 P"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E Obecność Campylobacter spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym PN -EN ISO 10272-1 P Zywnosc E, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia oraz z obszarow niezwiazanych z zywnoscia E Obecnosc Campylobacter spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym PN -EN ISO 10272-1 P","categories":["food","environment"],"row_index":373,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Campylobacter spp.","search_en":"Presence of Campylobacter spp. Culture method with biochemical and microscopic confirmation PN -EN ISO 10272-1 P","technique_en":"Culture method with biochemical and microscopic confirmation","search_zh":"弯曲杆菌属的检出 培养法（附生化与显微确证） PN -EN ISO 10272-1 P","technique_zh":"培养法（附生化与显微确证）","methodology_zh":"弯曲杆菌属的检出"},{"_id":"6a82c6ff884ede9a1b2c2ac2","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana","techniques":["Metoda hodowlana"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana","reference":"Procedury badawcze P","norm_bases":["Procedury badawcze P"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Obecność drobnoustrojów\nMetoda hodowlana Procedury badawcze P Zywnosc E Obecnosc drobnoustrojow\nMetoda hodowlana Procedury badawcze P","categories":["food","microbiology"],"row_index":374,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of microorganisms","search_en":"Food E Presence of microorganisms Culture method Procedury badawcze P","technique_en":"Culture method","test_object_en":"Food E","search_zh":"食品 E 微生物的检出 培养法 Procedury badawcze P","technique_zh":"培养法","test_object_zh":"食品 E","methodology_zh":"微生物的检出"},{"_id":"6a82c6ff884ede9a1b2c2ac3","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Pasze E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E, Tusze E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Procedury badawcze Normy P","norm_bases":["Procedury badawcze Normy P"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E, Tusze E Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Procedury badawcze Normy P Zywnosc E, Pasze E, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia oraz z obszarow niezwiazanych z zywnoscia E, Tusze E Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Procedury badawcze Normy P","categories":["food","environment","microbiology"],"row_index":375,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Microorganism count Plate method (pour plate) Procedury badawcze Normy P","technique_en":"Plate method (pour plate)","methodology_zh":"菌落总数","search_zh":"菌落总数 平板法（倾注培养） Procedury badawcze Normy P","technique_zh":"平板法（倾注培养）"},{"_id":"6a82c6ff884ede9a1b2c2ac4","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Pasze E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E, Tusze E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy)","reference":"Procedury badawcze Normy P","norm_bases":["Procedury badawcze Normy P"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E, Tusze E Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy) Procedury badawcze Normy P Zywnosc E, Pasze E, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia oraz z obszarow niezwiazanych z zywnoscia E, Tusze E Liczba drobnoustrojow\nMetoda plytkowa (posiew powierzchniowy) Procedury badawcze Normy P","categories":["food","environment","microbiology"],"row_index":376,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Microorganism count Plate method (spread plate) Procedury badawcze Normy P","technique_en":"Plate method (spread plate)","methodology_zh":"菌落总数","search_zh":"菌落总数 平板法（表面涂布） Procedury badawcze Normy P","technique_zh":"平板法（表面涂布）"},{"_id":"6a82c6ff884ede9a1b2c2ac5","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E","methodology":"Liczba Enterobacteriaceae","parameters":[],"technique":"Metoda płytek kontaktowych","techniques":["Metoda płytek kontaktowych"],"computed":[],"activity":"Liczba Enterobacteriaceae\nMetoda płytek kontaktowych","reference":"PB-89/LM P","norm_bases":["PB-89/LM P"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E Liczba Enterobacteriaceae\nMetoda płytek kontaktowych PB-89/LM P Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia oraz z obszarow niezwiazanych z zywnoscia E Liczba Enterobacteriaceae\nMetoda plytek kontaktowych PB-89/LM P","categories":["food","environment"],"row_index":377,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Enterobacteriaceae count","search_en":"Enterobacteriaceae count Contact plate method PB-89/LM P","technique_en":"Contact plate method","methodology_zh":"肠杆菌科（Enterobacteriaceae）计数","search_zh":"肠杆菌科（Enterobacteriaceae）计数 接触平皿法 PB-89/LM P","technique_zh":"接触平皿法"},{"_id":"6a82c6ff884ede9a1b2c2ac6","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E","methodology":"Ogólna liczba drobnoustrojów","parameters":[],"technique":"Metoda płytek kontaktowych","techniques":["Metoda płytek kontaktowych"],"computed":[],"activity":"Ogólna liczba drobnoustrojów\nMetoda płytek kontaktowych","reference":"PB-89/LM P","norm_bases":["PB-89/LM P"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E Ogólna liczba drobnoustrojów\nMetoda płytek kontaktowych PB-89/LM P Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia oraz z obszarow niezwiazanych z zywnoscia E Ogolna liczba drobnoustrojow\nMetoda plytek kontaktowych PB-89/LM P","categories":["food","environment","microbiology"],"row_index":378,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count","search_en":"Total viable count Contact plate method PB-89/LM P","technique_en":"Contact plate method","methodology_zh":"微生物总数","search_zh":"微生物总数 接触平皿法 PB-89/LM P","technique_zh":"接触平皿法"},{"_id":"6a82c6ff884ede9a1b2c2ac7","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Konserwy warzywno – mięsne, warzywne, owocowe","methodology":"Trwałość konserw","parameters":[],"technique":"Metoda próby termostatowej","techniques":["Metoda próby termostatowej"],"computed":[],"activity":"Trwałość konserw\nMetoda próby termostatowej","reference":"PN-A-75052-03:1990 M","norm_bases":["PN-A-75052-03:1990 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Konserwy warzywno – mięsne, warzywne, owocowe Trwałość konserw\nMetoda próby termostatowej PN-A-75052-03:1990 M Konserwy warzywno – miesne, warzywne, owocowe Trwalosc konserw\nMetoda proby termostatowej PN-A-75052-03:1990 M","categories":["other"],"row_index":379,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Shelf stability of canned products","search_en":"Canned vegetable – meat, vegetable and fruit products Shelf stability of canned products Thermostatic test method PN-A-75052-03:1990 M","technique_en":"Thermostatic test method","test_object_en":"Canned vegetable – meat, vegetable and fruit products","methodology_zh":"罐头保存性","search_zh":"蔬菜肉类罐头、蔬菜罐头、水果罐头 罐头保存性 恒温试验法 PN-A-75052-03:1990 M","technique_zh":"恒温试验法","test_object_zh":"蔬菜肉类罐头、蔬菜罐头、水果罐头"},{"_id":"6a82c6ff884ede9a1b2c2ac8","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Konserwy rybne","methodology":"Trwałość konserw","parameters":[],"technique":"Metoda próby termostatowej","techniques":["Metoda próby termostatowej"],"computed":[],"activity":"Trwałość konserw\nMetoda próby termostatowej","reference":"PN-A-86732:1992 pkt. 2.3.11 M","norm_bases":["PN-A-86732:1992 pkt. 2.3.11 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Konserwy rybne Trwałość konserw\nMetoda próby termostatowej PN-A-86732:1992 pkt. 2.3.11 M Konserwy rybne Trwalosc konserw\nMetoda proby termostatowej PN-A-86732:1992 pkt. 2.3.11 M","categories":["other"],"row_index":380,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Shelf stability of canned products","search_en":"Canned fish Shelf stability of canned products Thermostatic test method PN-A-86732:1992 pkt. 2.3.11 M","technique_en":"Thermostatic test method","test_object_en":"Canned fish","methodology_zh":"罐头保存性","search_zh":"鱼罐头 罐头保存性 恒温试验法 PN-A-86732:1992 pkt. 2.3.11 M","technique_zh":"恒温试验法","test_object_zh":"鱼罐头"},{"_id":"6a82c6ff884ede9a1b2c2ac9","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Konserwy mięsne","methodology":"Trwałość konserw","parameters":[],"technique":"Metoda próby termostatowej","techniques":["Metoda próby termostatowej"],"computed":[],"activity":"Trwałość konserw\nMetoda próby termostatowej","reference":"PN-A-82055-5:1994 M","norm_bases":["PN-A-82055-5:1994 M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Konserwy mięsne Trwałość konserw\nMetoda próby termostatowej PN-A-82055-5:1994 M Konserwy miesne Trwalosc konserw\nMetoda proby termostatowej PN-A-82055-5:1994 M","categories":["other"],"row_index":381,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Shelf stability of canned products","search_en":"Canned meat Shelf stability of canned products Thermostatic test method PN-A-82055-5:1994 M","technique_en":"Thermostatic test method","test_object_en":"Canned meat","methodology_zh":"罐头保存性","search_zh":"肉类罐头 罐头保存性 恒温试验法 PN-A-82055-5:1994 M","technique_zh":"恒温试验法","test_object_zh":"肉类罐头"},{"_id":"6a82c6ff884ede9a1b2c2aca","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Płyny do dializ, koncentraty do dializ, woda do dializ, woda ultraczysta E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda filtracji membranowej","reference":"Procedury badawcze Normy Farmakopea Polska M","norm_bases":["Procedury badawcze Normy Farmakopea Polska M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Płyny do dializ, koncentraty do dializ, woda do dializ, woda ultraczysta E Liczba drobnoustrojów\nMetoda filtracji membranowej Procedury badawcze Normy Farmakopea Polska M Plyny do dializ, koncentraty do dializ, woda do dializ, woda ultraczysta E Liczba drobnoustrojow\nMetoda filtracji membranowej Procedury badawcze Normy Farmakopea Polska M","categories":["water","microbiology"],"row_index":382,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Microorganism count Membrane filtration method Procedury badawcze Normy Farmakopea Polska M","technique_en":"Membrane filtration method","methodology_zh":"菌落总数","search_zh":"菌落总数 膜过滤法 Procedury badawcze Normy Farmakopea Polska M","technique_zh":"膜过滤法"},{"_id":"6a82c6ff884ede9a1b2c2acb","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Płyny do dializ, koncentraty do dializ, woda do dializ, woda ultraczysta E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Procedury badawcze Normy Farmakopea Polska M","norm_bases":["Procedury badawcze Normy Farmakopea Polska M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Płyny do dializ, koncentraty do dializ, woda do dializ, woda ultraczysta E Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Procedury badawcze Normy Farmakopea Polska M Plyny do dializ, koncentraty do dializ, woda do dializ, woda ultraczysta E Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Procedury badawcze Normy Farmakopea Polska M","categories":["water","microbiology"],"row_index":383,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Microorganism count Plate method (pour plate) Procedury badawcze Normy Farmakopea Polska M","technique_en":"Plate method (pour plate)","methodology_zh":"菌落总数","search_zh":"菌落总数 平板法（倾注培养） Procedury badawcze Normy Farmakopea Polska M","technique_zh":"平板法（倾注培养）"},{"_id":"6a82c6ff884ede9a1b2c2acc","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Płyny do dializ, koncentraty do dializ, woda do dializ, woda ultraczysta E","methodology":"Najbardziej prawdopodobna liczba drobnoustrojów","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda NPL","reference":"Procedury badawcze Normy M","norm_bases":["Procedury badawcze Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Płyny do dializ, koncentraty do dializ, woda do dializ, woda ultraczysta E Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda NPL Procedury badawcze Normy M Plyny do dializ, koncentraty do dializ, woda do dializ, woda ultraczysta E Najbardziej prawdopodobna liczba drobnoustrojow\nMetoda NPL Procedury badawcze Normy M","categories":["water","microbiology"],"row_index":384,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of microorganisms","search_en":"Most probable number of microorganisms MPN method Procedury badawcze Normy M","technique_en":"MPN method","search_zh":"微生物最可能数 最可能数法（MPN） Procedury badawcze Normy M","technique_zh":"最可能数法（MPN）","methodology_zh":"微生物最可能数"},{"_id":"6a82c6ff884ede9a1b2c2acd","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Płyny do dializ, koncentraty do dializ, woda do dializ, woda ultraczysta E","methodology":"Obecność endotoksyn bakteryjnych","parameters":[],"technique":"Metoda test LAL","techniques":["Metoda test LAL"],"computed":[],"activity":"Obecność endotoksyn bakteryjnych\nMetoda test LAL","reference":"Farmakopea Polska M","norm_bases":["Farmakopea Polska M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Płyny do dializ, koncentraty do dializ, woda do dializ, woda ultraczysta E Obecność endotoksyn bakteryjnych\nMetoda test LAL Farmakopea Polska M Plyny do dializ, koncentraty do dializ, woda do dializ, woda ultraczysta E Obecnosc endotoksyn bakteryjnych\nMetoda test LAL Farmakopea Polska M","categories":["water"],"row_index":385,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of bacterial endotoxins","search_en":"Presence of bacterial endotoxins LAL test method Farmakopea Polska M","technique_en":"LAL test method","methodology_zh":"细菌内毒素的检出","search_zh":"细菌内毒素的检出 Farmakopea Polska M"},{"_id":"6a82c6ff884ede9a1b2c2ace","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda filtracji membranowej","reference":"Procedury badawcze Normy Przepisy prawa Farmakopea Polska M","norm_bases":["Procedury badawcze Normy Przepisy prawa Farmakopea Polska M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Liczba drobnoustrojów\nMetoda filtracji membranowej Procedury badawcze Normy Przepisy prawa Farmakopea Polska M Woda E, Woda do spozycia przez ludzi E Liczba drobnoustrojow\nMetoda filtracji membranowej Procedury badawcze Normy Przepisy prawa Farmakopea Polska M","categories":["water","microbiology"],"row_index":386,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Water E, Water intended for human consumption E Microorganism count Membrane filtration method Procedury badawcze Normy Przepisy prawa Farmakopea Polska M","technique_en":"Membrane filtration method","test_object_en":"Water E, Water intended for human consumption E","methodology_zh":"菌落总数","search_zh":"水 E、生活饮用水 E 菌落总数 膜过滤法 Procedury badawcze Normy Przepisy prawa Farmakopea Polska M","technique_zh":"膜过滤法","test_object_zh":"水 E、生活饮用水 E"},{"_id":"6a82c6ff884ede9a1b2c2acf","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Procedury badawcze Normy Przepisy prawa Farmakopea Polska M","norm_bases":["Procedury badawcze Normy Przepisy prawa Farmakopea Polska M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Procedury badawcze Normy Przepisy prawa Farmakopea Polska M Woda E, Woda do spozycia przez ludzi E Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Procedury badawcze Normy Przepisy prawa Farmakopea Polska M","categories":["water","microbiology"],"row_index":387,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Water E, Water intended for human consumption E Microorganism count Plate method (pour plate) Procedury badawcze Normy Przepisy prawa Farmakopea Polska M","technique_en":"Plate method (pour plate)","test_object_en":"Water E, Water intended for human consumption E","methodology_zh":"菌落总数","search_zh":"水 E、生活饮用水 E 菌落总数 平板法（倾注培养） Procedury badawcze Normy Przepisy prawa Farmakopea Polska M","technique_zh":"平板法（倾注培养）","test_object_zh":"水 E、生活饮用水 E"},{"_id":"6a82c6ff884ede9a1b2c2ad0","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Najbardziej prawdopodobna liczba drobnoustrojów","parameters":[{"name":"Metoda NPL (hodowlana fermentacyjna probówkowa)"}],"technique":null,"techniques":[],"computed":[],"activity":"Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda NPL (hodowlana fermentacyjna probówkowa)","reference":"Procedury badawcze Normy Przepisy prawa Farmakopea Polska M","norm_bases":["Procedury badawcze Normy Przepisy prawa Farmakopea Polska M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda NPL (hodowlana fermentacyjna probówkowa) Procedury badawcze Normy Przepisy prawa Farmakopea Polska M Woda E, Woda do spozycia przez ludzi E Najbardziej prawdopodobna liczba drobnoustrojow\nMetoda NPL (hodowlana fermentacyjna probowkowa) Procedury badawcze Normy Przepisy prawa Farmakopea Polska M","categories":["water","microbiology"],"row_index":388,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of microorganisms","parameters_en":[{"name":"MPN method (culture fermentation tube)"}],"search_en":"Water E, Water intended for human consumption E Most probable number of microorganisms MPN method (culture fermentation tube) Procedury badawcze Normy Przepisy prawa Farmakopea Polska M","test_object_en":"Water E, Water intended for human consumption E","search_zh":"水 E、生活饮用水 E 微生物最可能数 MPN 法（试管发酵培养法） Procedury badawcze Normy Przepisy prawa Farmakopea Polska M","test_object_zh":"水 E、生活饮用水 E","methodology_zh":"微生物最可能数","parameters_zh":[{"name":"MPN 法（试管发酵培养法）"}]},{"_id":"6a82c6ff884ede9a1b2c2ad1","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem: biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem: biochemicznym i serologicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem: biochemicznym i serologicznym","reference":"Procedury badawcze Normy Przepisy prawa Farmakopea Polska M","norm_bases":["Procedury badawcze Normy Przepisy prawa Farmakopea Polska M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem: biochemicznym i serologicznym Procedury badawcze Normy Przepisy prawa Farmakopea Polska M Woda E, Woda do spozycia przez ludzi E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem: biochemicznym i serologicznym Procedury badawcze Normy Przepisy prawa Farmakopea Polska M","categories":["water","microbiology"],"row_index":389,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of microorganisms","search_en":"Water E, Water intended for human consumption E Presence of microorganisms Culture method with confirmation: biochemical and serological Procedury badawcze Normy Przepisy prawa Farmakopea Polska M","technique_en":"Culture method with confirmation: biochemical and serological","test_object_en":"Water E, Water intended for human consumption E","methodology_zh":"微生物的检出","search_zh":"水 E、生活饮用水 E 微生物的检出 Procedury badawcze Normy Przepisy prawa Farmakopea Polska M","test_object_zh":"水 E、生活饮用水 E"},{"_id":"6a82c6ff884ede9a1b2c2ad2","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Najbardziej prawdopodobna liczba drobnoustrojów","parameters":[],"technique":"Metoda zminiaturyzowana (NPL)","techniques":["Metoda zminiaturyzowana (NPL)"],"computed":[],"activity":"Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda zminiaturyzowana (NPL)","reference":"Procedury badawcze Normy Przepisy prawa Farmakopea Polska M","norm_bases":["Procedury badawcze Normy Przepisy prawa Farmakopea Polska M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda zminiaturyzowana (NPL) Procedury badawcze Normy Przepisy prawa Farmakopea Polska M Woda E, Woda do spozycia przez ludzi E Najbardziej prawdopodobna liczba drobnoustrojow\nMetoda zminiaturyzowana (NPL) Procedury badawcze Normy Przepisy prawa Farmakopea Polska M","categories":["water","microbiology"],"row_index":390,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of microorganisms","search_en":"Water E, Water intended for human consumption E Most probable number of microorganisms Miniaturized method (MPN) Procedury badawcze Normy Przepisy prawa Farmakopea Polska M","technique_en":"Miniaturized method (MPN)","test_object_en":"Water E, Water intended for human consumption E","search_zh":"水 E、生活饮用水 E 微生物最可能数 微量法（MPN） Procedury badawcze Normy Przepisy prawa Farmakopea Polska M","technique_zh":"微量法（MPN）","test_object_zh":"水 E、生活饮用水 E","methodology_zh":"微生物最可能数"},{"_id":"6a82c6ff884ede9a1b2c2ad3","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Najbardziej prawdopodobna liczba drobnoustrojów","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda NPL","reference":"Procedury badawcze Normy Przepisy prawa Farmakopea Polska M","norm_bases":["Procedury badawcze Normy Przepisy prawa Farmakopea Polska M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda NPL Procedury badawcze Normy Przepisy prawa Farmakopea Polska M Woda E, Woda do spozycia przez ludzi E Najbardziej prawdopodobna liczba drobnoustrojow\nMetoda NPL Procedury badawcze Normy Przepisy prawa Farmakopea Polska M","categories":["water","microbiology"],"row_index":391,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of microorganisms","search_en":"Water E, Water intended for human consumption E Most probable number of microorganisms MPN method Procedury badawcze Normy Przepisy prawa Farmakopea Polska M","technique_en":"MPN method","test_object_en":"Water E, Water intended for human consumption E","search_zh":"水 E、生活饮用水 E 微生物最可能数 最可能数法（MPN） Procedury badawcze Normy Przepisy prawa Farmakopea Polska M","technique_zh":"最可能数法（MPN）","test_object_zh":"水 E、生活饮用水 E","methodology_zh":"微生物最可能数"},{"_id":"6a82c6ff884ede9a1b2c2ad4","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E,","methodology":"Obecność endotoksyn bakteryjnych","parameters":[],"technique":"Metoda test LAL","techniques":["Metoda test LAL"],"computed":[],"activity":"Obecność endotoksyn bakteryjnych\nMetoda test LAL","reference":"Farmakopea Polska M","norm_bases":["Farmakopea Polska M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E, Obecność endotoksyn bakteryjnych\nMetoda test LAL Farmakopea Polska M Woda E, Woda do spozycia przez ludzi E, Obecnosc endotoksyn bakteryjnych\nMetoda test LAL Farmakopea Polska M","categories":["water"],"row_index":392,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of bacterial endotoxins","search_en":"Presence of bacterial endotoxins LAL test method Farmakopea Polska M","technique_en":"LAL test method","methodology_zh":"细菌内毒素的检出","search_zh":"细菌内毒素的检出 Farmakopea Polska M"},{"_id":"6a82c6ff884ede9a1b2c2ad5","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda filtracji membranowej","reference":"Procedury badawcze Normy M","norm_bases":["Procedury badawcze Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E Liczba drobnoustrojów\nMetoda filtracji membranowej Procedury badawcze Normy M Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia oraz z obszarow niezwiazanych z zywnoscia E Liczba drobnoustrojow\nMetoda filtracji membranowej Procedury badawcze Normy M","categories":["food","environment","microbiology"],"row_index":393,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Microorganism count Membrane filtration method Procedury badawcze Normy M","technique_en":"Membrane filtration method","methodology_zh":"菌落总数","search_zh":"菌落总数 膜过滤法 Procedury badawcze Normy M","technique_zh":"膜过滤法"},{"_id":"6a82c6ff884ede9a1b2c2ad6","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny i powierzchniowy)","techniques":["Metoda płytkowa (posiew wgłębny i powierzchniowy)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny i powierzchniowy)","reference":"Procedury badawcze Normy M","norm_bases":["Procedury badawcze Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny i powierzchniowy) Procedury badawcze Normy M Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia oraz z obszarow niezwiazanych z zywnoscia E Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny i powierzchniowy) Procedury badawcze Normy M","categories":["food","environment","microbiology"],"row_index":394,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Microorganism count Plate method (pour plate and spread plate) Procedury badawcze Normy M","technique_en":"Plate method (pour plate and spread plate)","methodology_zh":"菌落总数","search_zh":"菌落总数 平板法（倾注平板与表面涂布） Procedury badawcze Normy M","technique_zh":"平板法（倾注平板与表面涂布）"},{"_id":"6a82c6ff884ede9a1b2c2ad7","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem: - biochemicznym - biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem: - biochemicznym - biochemicznym i serologicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem: - biochemicznym - biochemicznym i serologicznym","reference":"Procedury badawcze Normy M","norm_bases":["Procedury badawcze Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem: - biochemicznym - biochemicznym i serologicznym Procedury badawcze Normy M Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia oraz z obszarow niezwiazanych z zywnoscia E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem: - biochemicznym - biochemicznym i serologicznym Procedury badawcze Normy M","categories":["food","environment","microbiology"],"row_index":395,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of microorganisms","search_en":"Presence of microorganisms Culture method with confirmation: - biochemical - biochemical and serological Procedury badawcze Normy M","technique_en":"Culture method with confirmation: - biochemical - biochemical and serological","methodology_zh":"微生物的检出","search_zh":"微生物的检出 Procedury badawcze Normy M"},{"_id":"6a82c6ff884ede9a1b2c2ad8","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E","methodology":"Liczba bakterii wskaźnikowych","parameters":[],"technique":"Metoda płytek kontaktowych","techniques":["Metoda płytek kontaktowych"],"computed":[],"activity":"Liczba bakterii wskaźnikowych\nMetoda płytek kontaktowych","reference":"Procedury badawcze M","norm_bases":["Procedury badawcze M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E Liczba bakterii wskaźnikowych\nMetoda płytek kontaktowych Procedury badawcze M Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia oraz z obszarow niezwiazanych z zywnoscia E Liczba bakterii wskaznikowych\nMetoda plytek kontaktowych Procedury badawcze M","categories":["food","environment","microbiology"],"row_index":396,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Contact plate method Procedury badawcze M","technique_en":"Contact plate method","search_zh":"接触平皿法 Procedury badawcze M","technique_zh":"接触平皿法"},{"_id":"6a82c6ff884ede9a1b2c2ad9","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E","methodology":"Liczba drożdży i pleśni","parameters":[],"technique":"Metoda płytek kontaktowych","techniques":["Metoda płytek kontaktowych"],"computed":[],"activity":"Liczba drożdży i pleśni\nMetoda płytek kontaktowych","reference":"Procedury badawcze M","norm_bases":["Procedury badawcze M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością oraz z obszarów niezwiązanych z żywnością E Liczba drożdży i pleśni\nMetoda płytek kontaktowych Procedury badawcze M Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia oraz z obszarow niezwiazanych z zywnoscia E Liczba drozdzy i plesni\nMetoda plytek kontaktowych Procedury badawcze M","categories":["food","environment"],"row_index":397,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Yeast and mould count","search_en":"Yeast and mould count Contact plate method Procedury badawcze M","technique_en":"Contact plate method","methodology_zh":"酵母菌与霉菌计数","search_zh":"酵母菌与霉菌计数 接触平皿法 Procedury badawcze M","technique_zh":"接触平皿法"},{"_id":"6a82c6ff884ede9a1b2c2ada","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba E, Grunty E, Komposty E, Osady E, Nawozy E, Środki wspomagające uprawę roślin E, Odpady, E : 02 01, 02 02, 02 03, 02 04, 02 05, 19 05, 19 06, 19 08, 19 09, 19 13, 20 03","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Gleba E, Grunty E, Komposty E, Osady E, Nawozy E, Środki wspomagające uprawę roślin E, Odpady, E : 02 01, 02 02, 02 03, 02 04, 02 05, 19 05, 19 06, 19 08, 19 09, 19 13, 20 03 Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Normy M Gleba E, Grunty E, Komposty E, Osady E, Nawozy E, Srodki wspomagajace uprawe roslin E, Odpady, E : 02 01, 02 02, 02 03, 02 04, 02 05, 19 05, 19 06, 19 08, 19 09, 19 13, 20 03 Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Normy M","categories":["environment","water","microbiology"],"row_index":398,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Microorganism count Plate method (pour plate) Normy M","technique_en":"Plate method (pour plate)","methodology_zh":"菌落总数","search_zh":"菌落总数 平板法（倾注培养） Normy M","technique_zh":"平板法（倾注培养）"},{"_id":"6a82c6ff884ede9a1b2c2adb","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba E, Grunty E, Komposty, Osady E, Nawozy E, Środki wspomagające uprawę roślin E, Odpady, E : 02 01, 02 02, 02 03, 02 04, 02 05, 10 01, 19 01, 19 05, 19 06, 19 08, 19 09, 19 13, 20 03","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda: - hodowlana - hodowlana fermentacyjna probówkowa - hodowlana z potwierdzeniem: - biochemicznym - biochemicznym i serologicznym","techniques":["Metoda: - hodowlana - hodowlana fermentacyjna probówkowa - hodowlana z potwierdzeniem: - biochemicznym - biochemicznym i serologicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda: - hodowlana - hodowlana fermentacyjna probówkowa - hodowlana z potwierdzeniem: - biochemicznym - biochemicznym i serologicznym","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Gleba E, Grunty E, Komposty, Osady E, Nawozy E, Środki wspomagające uprawę roślin E, Odpady, E : 02 01, 02 02, 02 03, 02 04, 02 05, 10 01, 19 01, 19 05, 19 06, 19 08, 19 09, 19 13, 20 03 Obecność drobnoustrojów\nMetoda: - hodowlana - hodowlana fermentacyjna probówkowa - hodowlana z potwierdzeniem: - biochemicznym - biochemicznym i serologicznym Normy M Gleba E, Grunty E, Komposty, Osady E, Nawozy E, Srodki wspomagajace uprawe roslin E, Odpady, E : 02 01, 02 02, 02 03, 02 04, 02 05, 10 01, 19 01, 19 05, 19 06, 19 08, 19 09, 19 13, 20 03 Obecnosc drobnoustrojow\nMetoda: - hodowlana - hodowlana fermentacyjna probowkowa - hodowlana z potwierdzeniem: - biochemicznym - biochemicznym i serologicznym Normy M","categories":["environment","water","microbiology"],"row_index":399,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of microorganisms","search_en":"Presence of microorganisms Method: - culture - culture fermentation tube - culture with confirmation: - biochemical - biochemical and serological Normy M","technique_en":"Method: - culture - culture fermentation tube - culture with confirmation: - biochemical - biochemical and serological","methodology_zh":"微生物的检出","search_zh":"微生物的检出 Normy M"},{"_id":"6a82c6ff884ede9a1b2c2adc","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba E, Grunty E, Komposty, Osady E, Nawozy E, Środki wspomagające uprawę roślin E, Odpady, E : 02 01, 02 02, 02 03, 02 04, 02 05, 10 01, 19 01, 19 05, 19 06, 19 08, 19 09, 19 13, 20 03","methodology":"Najbardziej prawdopodobna liczba drobnoustrojów","parameters":[],"technique":"Metoda NPL (hodowlana fermentacyjna probówkowa)","techniques":["Metoda NPL (hodowlana fermentacyjna probówkowa)"],"computed":[],"activity":"Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda NPL (hodowlana fermentacyjna probówkowa)","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Gleba E, Grunty E, Komposty, Osady E, Nawozy E, Środki wspomagające uprawę roślin E, Odpady, E : 02 01, 02 02, 02 03, 02 04, 02 05, 10 01, 19 01, 19 05, 19 06, 19 08, 19 09, 19 13, 20 03 Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda NPL (hodowlana fermentacyjna probówkowa) Normy M Gleba E, Grunty E, Komposty, Osady E, Nawozy E, Srodki wspomagajace uprawe roslin E, Odpady, E : 02 01, 02 02, 02 03, 02 04, 02 05, 10 01, 19 01, 19 05, 19 06, 19 08, 19 09, 19 13, 20 03 Najbardziej prawdopodobna liczba drobnoustrojow\nMetoda NPL (hodowlana fermentacyjna probowkowa) Normy M","categories":["environment","water","microbiology"],"row_index":400,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of microorganisms","search_en":"Most probable number of microorganisms MPN method (culture fermentation tube) Normy M","technique_en":"MPN method (culture fermentation tube)","methodology_zh":"微生物最可能数","search_zh":"微生物最可能数 MPN 法（试管发酵培养法） Normy M","technique_zh":"MPN 法（试管发酵培养法）"},{"_id":"6a82c6ff884ede9a1b2c2add","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba E, Grunty E, Komposty, Osady E, Nawozy E, Środki wspomagające uprawę roślin E, Odpady, E : 02 01, 02 02, 02 03, 02 04, 02 05, 10 01, 19 01, 19 05, 19 06, 19 08, 19 09, 19 13, 20 03","methodology":"Najbardziej prawdopodobna liczba drobnoustrojów","parameters":[],"technique":"Metoda zminiaturyzowana (NPL)","techniques":["Metoda zminiaturyzowana (NPL)"],"computed":[],"activity":"Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda zminiaturyzowana (NPL)","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Gleba E, Grunty E, Komposty, Osady E, Nawozy E, Środki wspomagające uprawę roślin E, Odpady, E : 02 01, 02 02, 02 03, 02 04, 02 05, 10 01, 19 01, 19 05, 19 06, 19 08, 19 09, 19 13, 20 03 Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda zminiaturyzowana (NPL) Normy M Gleba E, Grunty E, Komposty, Osady E, Nawozy E, Srodki wspomagajace uprawe roslin E, Odpady, E : 02 01, 02 02, 02 03, 02 04, 02 05, 10 01, 19 01, 19 05, 19 06, 19 08, 19 09, 19 13, 20 03 Najbardziej prawdopodobna liczba drobnoustrojow\nMetoda zminiaturyzowana (NPL) Normy M","categories":["environment","water","microbiology"],"row_index":401,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of microorganisms","search_en":"Most probable number of microorganisms Miniaturized method (MPN) Normy M","technique_en":"Miniaturized method (MPN)","search_zh":"微生物最可能数 微量法（MPN） Normy M","technique_zh":"微量法（MPN）","methodology_zh":"微生物最可能数"},{"_id":"6a82c6ff884ede9a1b2c2ade","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba E, Grunty E, Komposty, Osady E, Nawozy E, Środki wspomagające uprawę roślin E, Odpady, E : 02 01, 02 02, 02 03, 02 04, 02 05, 10 01, 19 01, 19 05, 19 06, 19 08, 19 09, 19 13, 20 03","methodology":"Najbardziej prawdopodobna liczba drobnoustrojów","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda NPL","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Gleba E, Grunty E, Komposty, Osady E, Nawozy E, Środki wspomagające uprawę roślin E, Odpady, E : 02 01, 02 02, 02 03, 02 04, 02 05, 10 01, 19 01, 19 05, 19 06, 19 08, 19 09, 19 13, 20 03 Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda NPL Normy M Gleba E, Grunty E, Komposty, Osady E, Nawozy E, Srodki wspomagajace uprawe roslin E, Odpady, E : 02 01, 02 02, 02 03, 02 04, 02 05, 10 01, 19 01, 19 05, 19 06, 19 08, 19 09, 19 13, 20 03 Najbardziej prawdopodobna liczba drobnoustrojow\nMetoda NPL Normy M","categories":["environment","water","microbiology"],"row_index":402,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of microorganisms","search_en":"Most probable number of microorganisms MPN method Normy M","technique_en":"MPN method","search_zh":"微生物最可能数 最可能数法（MPN） Normy M","technique_zh":"最可能数法（MPN）","methodology_zh":"微生物最可能数"},{"_id":"6a82c6ff884ede9a1b2c2adf","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba E, Grunty E, Komposty, Osady E, Nawozy E, Środki wspomagające uprawę roślin E, Odpady, E : 02 01, 02 02, 02 03, 02 04, 02 05, 10 01, 19 01, 19 05, 19 06, 19 08, 19 09, 19 13, 20 03","methodology":"Obecność i liczba żywych jaj pasożytów jelitowych","parameters":[],"technique":"Metoda flotacji, mikroskopowa","techniques":["Metoda flotacji, mikroskopowa"],"computed":[],"activity":"Obecność i liczba żywych jaj pasożytów jelitowych\nMetoda flotacji, mikroskopowa","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Gleba E, Grunty E, Komposty, Osady E, Nawozy E, Środki wspomagające uprawę roślin E, Odpady, E : 02 01, 02 02, 02 03, 02 04, 02 05, 10 01, 19 01, 19 05, 19 06, 19 08, 19 09, 19 13, 20 03 Obecność i liczba żywych jaj pasożytów jelitowych\nMetoda flotacji, mikroskopowa Procedury badawcze Gleba E, Grunty E, Komposty, Osady E, Nawozy E, Srodki wspomagajace uprawe roslin E, Odpady, E : 02 01, 02 02, 02 03, 02 04, 02 05, 10 01, 19 01, 19 05, 19 06, 19 08, 19 09, 19 13, 20 03 Obecnosc i liczba zywych jaj pasozytow jelitowych\nMetoda flotacji, mikroskopowa Procedury badawcze","categories":["environment","water"],"row_index":403,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Flotation method, microscopic Procedury badawcze","technique_en":"Flotation method, microscopic","search_zh":"浮选显微镜法 Procedury badawcze","technique_zh":"浮选显微镜法"},{"_id":"6a82c6ff884ede9a1b2c2ae0","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Ścieki E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda: - hodowlana fermentacyjna probówkowa - hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda: - hodowlana fermentacyjna probówkowa - hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda: - hodowlana fermentacyjna probówkowa - hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Ścieki E Obecność drobnoustrojów\nMetoda: - hodowlana fermentacyjna probówkowa - hodowlana z potwierdzeniem biochemicznym i serologicznym Normy M Scieki E Obecnosc drobnoustrojow\nMetoda: - hodowlana fermentacyjna probowkowa - hodowlana z potwierdzeniem biochemicznym i serologicznym Normy M","categories":["water","microbiology"],"row_index":404,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of microorganisms","search_en":"Wastewater E Presence of microorganisms Method: - culture fermentation tube - culture with biochemical and serological confirmation Normy M","technique_en":"Method: - culture fermentation tube - culture with biochemical and serological confirmation","test_object_en":"Wastewater E","methodology_zh":"微生物的检出","search_zh":"微生物的检出 Normy M"},{"_id":"6a82c6ff884ede9a1b2c2ae1","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Ścieki E","methodology":"Najbardziej prawdopodobna liczba drobnoustrojów","parameters":[],"technique":"Metoda NPL (hodowlana fermentacyjna probówkowa)","techniques":["Metoda NPL (hodowlana fermentacyjna probówkowa)"],"computed":[],"activity":"Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda NPL (hodowlana fermentacyjna probówkowa)","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Ścieki E Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda NPL (hodowlana fermentacyjna probówkowa) Normy M Scieki E Najbardziej prawdopodobna liczba drobnoustrojow\nMetoda NPL (hodowlana fermentacyjna probowkowa) Normy M","categories":["water","microbiology"],"row_index":405,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of microorganisms","search_en":"Wastewater E Most probable number of microorganisms MPN method (culture fermentation tube) Normy M","technique_en":"MPN method (culture fermentation tube)","test_object_en":"Wastewater E","methodology_zh":"微生物最可能数","search_zh":"微生物最可能数 MPN 法（试管发酵培养法） Normy M","technique_zh":"MPN 法（试管发酵培养法）"},{"_id":"6a82c6ff884ede9a1b2c2ae2","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Ścieki E","methodology":"Najbardziej prawdopodobna liczba drobnoustrojów","parameters":[],"technique":"Metoda zminiaturyzowana (NPL)","techniques":["Metoda zminiaturyzowana (NPL)"],"computed":[],"activity":"Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda zminiaturyzowana (NPL)","reference":"Normy M","norm_bases":["Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Ścieki E Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda zminiaturyzowana (NPL) Normy M Scieki E Najbardziej prawdopodobna liczba drobnoustrojow\nMetoda zminiaturyzowana (NPL) Normy M","categories":["water","microbiology"],"row_index":406,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of microorganisms","search_en":"Wastewater E Most probable number of microorganisms Miniaturized method (MPN) Normy M","technique_en":"Miniaturized method (MPN)","test_object_en":"Wastewater E","search_zh":"微生物最可能数 微量法（MPN） Normy M","technique_zh":"微量法（MPN）","methodology_zh":"微生物最可能数"},{"_id":"6a82c6ff884ede9a1b2c2ae3","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Ścieki E","methodology":"Obecność i liczba żywych jaj pasożytów jelitowych","parameters":[],"technique":"Metoda flotacji (mikroskopowa)","techniques":["Metoda flotacji (mikroskopowa)"],"computed":[],"activity":"Obecność i liczba żywych jaj pasożytów jelitowych\nMetoda flotacji (mikroskopowa)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Ścieki E Obecność i liczba żywych jaj pasożytów jelitowych\nMetoda flotacji (mikroskopowa) Procedury badawcze Scieki E Obecnosc i liczba zywych jaj pasozytow jelitowych\nMetoda flotacji (mikroskopowa) Procedury badawcze","categories":["water"],"row_index":407,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Wastewater E Flotation method (microscopic) Procedury badawcze","technique_en":"Flotation method (microscopic)","test_object_en":"Wastewater E"},{"_id":"6a82c6ff884ede9a1b2c2ae4","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Powietrze E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa","techniques":["Metoda płytkowa"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa","reference":"Procedury badawcze Normy M","norm_bases":["Procedury badawcze Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Powietrze E Liczba drobnoustrojów\nMetoda płytkowa Procedury badawcze Normy M Powietrze E Liczba drobnoustrojow\nMetoda plytkowa Procedury badawcze Normy M","categories":["environment","microbiology"],"row_index":408,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Air E Microorganism count Plate method Procedury badawcze Normy M","technique_en":"Plate method","test_object_en":"Air E","methodology_zh":"菌落总数","search_zh":"空气 E 菌落总数 平板法 Procedury badawcze Normy M","technique_zh":"平板法","test_object_zh":"空气 E"},{"_id":"6a82c6ff884ede9a1b2c2ae5","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Powietrze E","methodology":"Liczba drożdży i pleśni","parameters":[],"technique":"Metoda płytkowa","techniques":["Metoda płytkowa"],"computed":[],"activity":"Liczba drożdży i pleśni\nMetoda płytkowa","reference":"Procedury badawcze Normy M","norm_bases":["Procedury badawcze Normy M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Powietrze E Liczba drożdży i pleśni\nMetoda płytkowa Procedury badawcze Normy M Powietrze E Liczba drozdzy i plesni\nMetoda plytkowa Procedury badawcze Normy M","categories":["environment"],"row_index":409,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Yeast and mould count","search_en":"Air E Yeast and mould count Plate method Procedury badawcze Normy M","technique_en":"Plate method","test_object_en":"Air E","methodology_zh":"酵母菌与霉菌计数","search_zh":"空气 E 酵母菌与霉菌计数 平板法 Procedury badawcze Normy M","technique_zh":"平板法","test_object_zh":"空气 E"},{"_id":"6a82c6ff884ede9a1b2c2ae6","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Pasze E, Tusze E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem: - biochemicznym - biochemicznym i serologicznym - serologicznym","techniques":["Metoda hodowlana z potwierdzeniem: - biochemicznym - biochemicznym i serologicznym - serologicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem: - biochemicznym - biochemicznym i serologicznym - serologicznym","reference":"Procedury badawcze Normy Przepisy prawa M","norm_bases":["Procedury badawcze Normy Przepisy prawa M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E, Tusze E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem: - biochemicznym - biochemicznym i serologicznym - serologicznym Procedury badawcze Normy Przepisy prawa M Zywnosc E, Pasze E, Tusze E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem: - biochemicznym - biochemicznym i serologicznym - serologicznym Procedury badawcze Normy Przepisy prawa M","categories":["food","microbiology"],"row_index":410,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of microorganisms","search_en":"Presence of microorganisms Culture method with confirmation: - biochemical - biochemical and serological - serological Procedury badawcze Normy Przepisy prawa M","technique_en":"Culture method with confirmation: - biochemical - biochemical and serological - serological","methodology_zh":"微生物的检出","search_zh":"微生物的检出 Procedury badawcze Normy Przepisy prawa M"},{"_id":"6a82c6ff884ede9a1b2c2ae7","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Żywność E, Pasze E, Tusze E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny i powierzchniowy)","techniques":["Metoda płytkowa (posiew wgłębny i powierzchniowy)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny i powierzchniowy)","reference":"Procedury badawcze Normy Przepisy prawa M","norm_bases":["Procedury badawcze Normy Przepisy prawa M"],"lab_section":null,"lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych Wykaz działań prowadzonych w ramach elastycznego zakresu akredytacji jest publicznie udostępniany przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E, Tusze E Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny i powierzchniowy) Procedury badawcze Normy Przepisy prawa M Zywnosc E, Pasze E, Tusze E Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny i powierzchniowy) Procedury badawcze Normy Przepisy prawa M","categories":["food","microbiology"],"row_index":411,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Microorganism count Plate method (pour plate and spread plate) Procedury badawcze Normy Przepisy prawa M","technique_en":"Plate method (pour plate and spread plate)","methodology_zh":"菌落总数","search_zh":"菌落总数 平板法（倾注平板与表面涂布） Procedury badawcze Normy Przepisy prawa M","technique_zh":"平板法（倾注平板与表面涂布）"},{"_id":"6a82c6ff884ede9a1b2c2ae8","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Kosmetyki i chemia gospodarcza","methodology":"pH","parameters":[{"name":"Zakres","range":"(3,00 – 11,00)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (3,00 – 11,00)\nMetoda potencjometryczna","reference":"PB-1/LK, wyd.7 z dnia 13.01.2022 W","norm_bases":["PB-1/LK, wyd.7 z dnia 13.01.2022 W"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kosmetyki i chemia gospodarcza pH\nZakres (3,00 – 11,00)\nMetoda potencjometryczna PB-1/LK, wyd.7 z dnia 13.01.2022 W Kosmetyki i chemia gospodarcza pH\nZakres (3,00 – 11,00)\nMetoda potencjometryczna PB-1/LK, wyd.7 z dnia 13.01.2022 W","categories":["pharma"],"row_index":412,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"(3,00 – 11,00)"}],"search_en":"Cosmetics and household chemicals pH Potentiometric method Range PB-1/LK, wyd.7 z dnia 13.01.2022 W","technique_en":"Potentiometric method","test_object_en":"Cosmetics and household chemicals","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(3,00 – 11,00)"}],"search_zh":"化妆品与家用化学品 pH 值 电位法 范围 PB-1/LK, wyd.7 z dnia 13.01.2022 W","technique_zh":"电位法","test_object_zh":"化妆品与家用化学品"},{"_id":"6a82c6ff884ede9a1b2c2ae9","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Kosmetyki i chemia gospodarcza","methodology":"Gęstość","parameters":[{"name":"Zakres","range":"(0,700 – 1,400) g/cm3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość\nZakres (0,700 – 1,400) g/cm3\nMetoda oscylacyjna","reference":"PB-2/LK, wyd.6 z dnia 13.01.2022 W","norm_bases":["PB-2/LK, wyd.6 z dnia 13.01.2022 W"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kosmetyki i chemia gospodarcza Gęstość\nZakres (0,700 – 1,400) g/cm3\nMetoda oscylacyjna PB-2/LK, wyd.6 z dnia 13.01.2022 W Kosmetyki i chemia gospodarcza Gestosc\nZakres (0,700 – 1,400) g/cm3\nMetoda oscylacyjna PB-2/LK, wyd.6 z dnia 13.01.2022 W","categories":["pharma"],"row_index":413,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density","parameters_en":[{"name":"Range","range":"(0,700 – 1,400) g/cm3"}],"search_en":"Cosmetics and household chemicals Density Oscillation method Range PB-2/LK, wyd.6 z dnia 13.01.2022 W","technique_en":"Oscillation method","test_object_en":"Cosmetics and household chemicals","methodology_zh":"密度","parameters_zh":[{"name":"范围","range":"(0,700 – 1,400) g/cm3"}],"search_zh":"化妆品与家用化学品 密度 振荡法 范围 PB-2/LK, wyd.6 z dnia 13.01.2022 W","technique_zh":"振荡法","test_object_zh":"化妆品与家用化学品"},{"_id":"6a82c6ff884ede9a1b2c2aea","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Kosmetyki i chemia gospodarcza","methodology":"Lepkość dynamiczna","parameters":[{"name":"Zakres","range":"(50,00 – 30000) mPa s"}],"technique":"Metoda Brookfield’a (z zastosowaniem lepkościomierza rotacyjnego)","techniques":["Metoda Brookfield’a (z zastosowaniem lepkościomierza rotacyjnego)"],"computed":[],"activity":"Lepkość dynamiczna\nZakres (50,00 – 30000) mPa s\nMetoda Brookfield’a (z zastosowaniem lepkościomierza rotacyjnego)","reference":"PB-5/LK, wyd.5 z dnia 13.01.2022 W","norm_bases":["PB-5/LK, wyd.5 z dnia 13.01.2022 W"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kosmetyki i chemia gospodarcza Lepkość dynamiczna\nZakres (50,00 – 30000) mPa s\nMetoda Brookfield’a (z zastosowaniem lepkościomierza rotacyjnego) PB-5/LK, wyd.5 z dnia 13.01.2022 W Kosmetyki i chemia gospodarcza Lepkosc dynamiczna\nZakres (50,00 – 30000) mPa s\nMetoda Brookfield’a (z zastosowaniem lepkosciomierza rotacyjnego) PB-5/LK, wyd.5 z dnia 13.01.2022 W","categories":["pharma"],"row_index":414,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dynamic viscosity","parameters_en":[{"name":"Range","range":"(50,00 – 30000) mPa s"}],"search_en":"Cosmetics and household chemicals Dynamic viscosity Brookfield method (using a rotational viscometer) Range PB-5/LK, wyd.5 z dnia 13.01.2022 W","technique_en":"Brookfield method (using a rotational viscometer)","test_object_en":"Cosmetics and household chemicals","methodology_zh":"动力粘度","parameters_zh":[{"name":"范围","range":"(50,00 – 30000) mPa s"}],"search_zh":"化妆品与家用化学品 动力粘度 范围 PB-5/LK, wyd.5 z dnia 13.01.2022 W","test_object_zh":"化妆品与家用化学品"},{"_id":"6a82c6ff884ede9a1b2c2aeb","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Kosmetyki i chemia gospodarcza","methodology":"Masa netto","parameters":[{"name":"Zakres","range":"(1 – 3000) g"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Masa netto\nZakres (1 – 3000) g\nMetoda wagowa","reference":"PB-6/LK, wyd.6 z dnia 13.01.2022 W","norm_bases":["PB-6/LK, wyd.6 z dnia 13.01.2022 W"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kosmetyki i chemia gospodarcza Masa netto\nZakres (1 – 3000) g\nMetoda wagowa PB-6/LK, wyd.6 z dnia 13.01.2022 W Kosmetyki i chemia gospodarcza Masa netto\nZakres (1 – 3000) g\nMetoda wagowa PB-6/LK, wyd.6 z dnia 13.01.2022 W","categories":["pharma"],"row_index":415,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net weight","parameters_en":[{"name":"Range","range":"(1 – 3000) g"}],"search_en":"Cosmetics and household chemicals Net weight Gravimetric method Range PB-6/LK, wyd.6 z dnia 13.01.2022 W","technique_en":"Gravimetric method","test_object_en":"Cosmetics and household chemicals","parameters_zh":[{"name":"范围","range":"(1 – 3000) g"}],"search_zh":"化妆品与家用化学品 净重 重量法 范围 PB-6/LK, wyd.6 z dnia 13.01.2022 W","technique_zh":"重量法","test_object_zh":"化妆品与家用化学品","methodology_zh":"净重"},{"_id":"6a82c6ff884ede9a1b2c2aec","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Kosmetyki i chemia gospodarcza","methodology":"Objętość netto","parameters":[{"name":"Zakres","range":"(1 – 2000) ml"}],"technique":"Metoda objętościowa","techniques":["Metoda objętościowa"],"computed":[],"activity":"Objętość netto\nZakres (1 – 2000) ml\nMetoda objętościowa","reference":"PB-6/LK, wyd.6 z dnia 13.01.2022 W","norm_bases":["PB-6/LK, wyd.6 z dnia 13.01.2022 W"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kosmetyki i chemia gospodarcza Objętość netto\nZakres (1 – 2000) ml\nMetoda objętościowa PB-6/LK, wyd.6 z dnia 13.01.2022 W Kosmetyki i chemia gospodarcza Objetosc netto\nZakres (1 – 2000) ml\nMetoda objetosciowa PB-6/LK, wyd.6 z dnia 13.01.2022 W","categories":["pharma"],"row_index":416,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net volume","parameters_en":[{"name":"Range","range":"(1 – 2000) ml"}],"search_en":"Cosmetics and household chemicals Net volume Volumetric method Range PB-6/LK, wyd.6 z dnia 13.01.2022 W","technique_en":"Volumetric method","test_object_en":"Cosmetics and household chemicals","parameters_zh":[{"name":"范围","range":"(1 – 2000) ml"}],"search_zh":"化妆品与家用化学品 容量法 范围 PB-6/LK, wyd.6 z dnia 13.01.2022 W","technique_zh":"容量法","test_object_zh":"化妆品与家用化学品"},{"_id":"6a82c6ff884ede9a1b2c2aed","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Kosmetyki i chemia gospodarcza","methodology":"Wymiary","parameters":[{"name":"Zakres","range":"(0,001 – 50) cm"}],"technique":"Metoda pomiaru długości","techniques":["Metoda pomiaru długości"],"computed":[],"activity":"Wymiary\nZakres (0,001 – 50) cm\nMetoda pomiaru długości","reference":"PB-7/LK, wyd.6 z dnia 13.01.2022 W","norm_bases":["PB-7/LK, wyd.6 z dnia 13.01.2022 W"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kosmetyki i chemia gospodarcza Wymiary\nZakres (0,001 – 50) cm\nMetoda pomiaru długości PB-7/LK, wyd.6 z dnia 13.01.2022 W Kosmetyki i chemia gospodarcza Wymiary\nZakres (0,001 – 50) cm\nMetoda pomiaru dlugosci PB-7/LK, wyd.6 z dnia 13.01.2022 W","categories":["pharma"],"row_index":417,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dimensions","parameters_en":[{"name":"Range","range":"(0,001 – 50) cm"}],"search_en":"Cosmetics and household chemicals Dimensions Length measurement method Range PB-7/LK, wyd.6 z dnia 13.01.2022 W","technique_en":"Length measurement method","test_object_en":"Cosmetics and household chemicals","parameters_zh":[{"name":"范围","range":"(0,001 – 50) cm"}],"search_zh":"化妆品与家用化学品 尺寸 范围 PB-7/LK, wyd.6 z dnia 13.01.2022 W","methodology_zh":"尺寸","test_object_zh":"化妆品与家用化学品"},{"_id":"6a82c6ff884ede9a1b2c2aee","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Kosmetyki i chemia gospodarcza","methodology":"Gramatura (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gramatura (z obliczeń)","reference":"PB-7/LK, wyd.6 z dnia 13.01.2022 W","norm_bases":["PB-7/LK, wyd.6 z dnia 13.01.2022 W"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kosmetyki i chemia gospodarcza Gramatura (z obliczeń) PB-7/LK, wyd.6 z dnia 13.01.2022 W Kosmetyki i chemia gospodarcza Gramatura (z obliczen) PB-7/LK, wyd.6 z dnia 13.01.2022 W","categories":["pharma"],"row_index":418,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Grammage (calculated)","search_en":"Cosmetics and household chemicals Grammage (calculated) PB-7/LK, wyd.6 z dnia 13.01.2022 W","test_object_en":"Cosmetics and household chemicals","search_zh":"化妆品与家用化学品 PB-7/LK, wyd.6 z dnia 13.01.2022 W","test_object_zh":"化妆品与家用化学品"},{"_id":"6a82c6ff884ede9a1b2c2aef","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Kosmetyki i chemia gospodarcza","methodology":"Sucha masa","parameters":[{"name":"Zakres","range":"(1,0 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa\nZakres (1,0 – 99,0) %\nMetoda wagowa","reference":"PB-20/LK, wyd.2 z dnia 13.01.2022 W","norm_bases":["PB-20/LK, wyd.2 z dnia 13.01.2022 W"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kosmetyki i chemia gospodarcza Sucha masa\nZakres (1,0 – 99,0) %\nMetoda wagowa PB-20/LK, wyd.2 z dnia 13.01.2022 W Kosmetyki i chemia gospodarcza Sucha masa\nZakres (1,0 – 99,0) %\nMetoda wagowa PB-20/LK, wyd.2 z dnia 13.01.2022 W","categories":["pharma"],"row_index":419,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter","parameters_en":[{"name":"Range","range":"(1,0 – 99,0) %"}],"search_en":"Cosmetics and household chemicals Dry matter Gravimetric method Range PB-20/LK, wyd.2 z dnia 13.01.2022 W","technique_en":"Gravimetric method","test_object_en":"Cosmetics and household chemicals","methodology_zh":"干物质","parameters_zh":[{"name":"范围","range":"(1,0 – 99,0) %"}],"search_zh":"化妆品与家用化学品 干物质 重量法 范围 PB-20/LK, wyd.2 z dnia 13.01.2022 W","technique_zh":"重量法","test_object_zh":"化妆品与家用化学品"},{"_id":"6a82c6ff884ede9a1b2c2af0","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Wyroby medyczne: emulsje, kremy, maści, pasty do zębów, kleje, kremy do protez, pianki, gliceryna, płyny, krople, żele, syropy, szampony","methodology":"pH","parameters":[{"name":"Zakres","range":"(3,00 – 11,00)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (3,00 – 11,00)\nMetoda potencjometryczna","reference":"PB-1/LK, wyd.7 z dnia 13.01.2022 W","norm_bases":["PB-1/LK, wyd.7 z dnia 13.01.2022 W"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby medyczne: emulsje, kremy, maści, pasty do zębów, kleje, kremy do protez, pianki, gliceryna, płyny, krople, żele, syropy, szampony pH\nZakres (3,00 – 11,00)\nMetoda potencjometryczna PB-1/LK, wyd.7 z dnia 13.01.2022 W Wyroby medyczne: emulsje, kremy, masci, pasty do zebow, kleje, kremy do protez, pianki, gliceryna, plyny, krople, zele, syropy, szampony pH\nZakres (3,00 – 11,00)\nMetoda potencjometryczna PB-1/LK, wyd.7 z dnia 13.01.2022 W","categories":["other"],"row_index":420,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"(3,00 – 11,00)"}],"search_en":"Medical devices: emulsions, creams, ointments, toothpastes, adhesives, denture creams, foams, glycerine, liquids, drops, gels, syrups, shampoos pH Potentiometric method Range PB-1/LK, wyd.7 z dnia 13.01.2022 W","technique_en":"Potentiometric method","test_object_en":"Medical devices: emulsions, creams, ointments, toothpastes, adhesives, denture creams, foams, glycerine, liquids, drops, gels, syrups, shampoos","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(3,00 – 11,00)"}],"search_zh":"医疗器械：乳剂、乳膏、软膏、牙膏、胶粘剂、义齿粘固剂、泡沫、甘油、溶液、滴剂、凝胶、糖浆、洗发剂 pH 值 电位法 范围 PB-1/LK, wyd.7 z dnia 13.01.2022 W","technique_zh":"电位法","test_object_zh":"医疗器械：乳剂、乳膏、软膏、牙膏、胶粘剂、义齿粘固剂、泡沫、甘油、溶液、滴剂、凝胶、糖浆、洗发剂"},{"_id":"6a82c6ff884ede9a1b2c2af1","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Wyroby medyczne: emulsje, kremy, maści, pasty do zębów, kleje, kremy do protez, pianki, gliceryna, płyny, krople, żele, syropy, szampony","methodology":"Gęstość","parameters":[{"name":"Zakres","range":"(0,700 – 1,400) g/cm3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość\nZakres (0,700 – 1,400) g/cm3\nMetoda oscylacyjna","reference":"PB-2/LK, wyd.6 z dnia 13.01.2022 W","norm_bases":["PB-2/LK, wyd.6 z dnia 13.01.2022 W"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby medyczne: emulsje, kremy, maści, pasty do zębów, kleje, kremy do protez, pianki, gliceryna, płyny, krople, żele, syropy, szampony Gęstość\nZakres (0,700 – 1,400) g/cm3\nMetoda oscylacyjna PB-2/LK, wyd.6 z dnia 13.01.2022 W Wyroby medyczne: emulsje, kremy, masci, pasty do zebow, kleje, kremy do protez, pianki, gliceryna, plyny, krople, zele, syropy, szampony Gestosc\nZakres (0,700 – 1,400) g/cm3\nMetoda oscylacyjna PB-2/LK, wyd.6 z dnia 13.01.2022 W","categories":["other"],"row_index":421,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density","parameters_en":[{"name":"Range","range":"(0,700 – 1,400) g/cm3"}],"search_en":"Medical devices: emulsions, creams, ointments, toothpastes, adhesives, denture creams, foams, glycerine, liquids, drops, gels, syrups, shampoos Density Oscillation method Range PB-2/LK, wyd.6 z dnia 13.01.2022 W","technique_en":"Oscillation method","test_object_en":"Medical devices: emulsions, creams, ointments, toothpastes, adhesives, denture creams, foams, glycerine, liquids, drops, gels, syrups, shampoos","methodology_zh":"密度","parameters_zh":[{"name":"范围","range":"(0,700 – 1,400) g/cm3"}],"search_zh":"医疗器械：乳剂、乳膏、软膏、牙膏、胶粘剂、义齿粘固剂、泡沫、甘油、溶液、滴剂、凝胶、糖浆、洗发剂 密度 振荡法 范围 PB-2/LK, wyd.6 z dnia 13.01.2022 W","technique_zh":"振荡法","test_object_zh":"医疗器械：乳剂、乳膏、软膏、牙膏、胶粘剂、义齿粘固剂、泡沫、甘油、溶液、滴剂、凝胶、糖浆、洗发剂"},{"_id":"6a82c6ff884ede9a1b2c2af2","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Wyroby medyczne: emulsje, kremy, maści, pasty do zębów, kleje, kremy do protez, pianki, gliceryna, płyny, krople, żele, syropy, szampony","methodology":"Lepkość dynamiczna","parameters":[{"name":"Zakres","range":"(50,00 – 30000) mPa s"}],"technique":"Metoda Brookfield’a (z zastosowaniem lepkościomierza rotacyjnego)","techniques":["Metoda Brookfield’a (z zastosowaniem lepkościomierza rotacyjnego)"],"computed":[],"activity":"Lepkość dynamiczna\nZakres (50,00 – 30000) mPa s\nMetoda Brookfield’a (z zastosowaniem lepkościomierza rotacyjnego)","reference":"PB-5/LK, wyd.5 z dnia 13.01.2022 W","norm_bases":["PB-5/LK, wyd.5 z dnia 13.01.2022 W"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby medyczne: emulsje, kremy, maści, pasty do zębów, kleje, kremy do protez, pianki, gliceryna, płyny, krople, żele, syropy, szampony Lepkość dynamiczna\nZakres (50,00 – 30000) mPa s\nMetoda Brookfield’a (z zastosowaniem lepkościomierza rotacyjnego) PB-5/LK, wyd.5 z dnia 13.01.2022 W Wyroby medyczne: emulsje, kremy, masci, pasty do zebow, kleje, kremy do protez, pianki, gliceryna, plyny, krople, zele, syropy, szampony Lepkosc dynamiczna\nZakres (50,00 – 30000) mPa s\nMetoda Brookfield’a (z zastosowaniem lepkosciomierza rotacyjnego) PB-5/LK, wyd.5 z dnia 13.01.2022 W","categories":["other"],"row_index":422,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dynamic viscosity","parameters_en":[{"name":"Range","range":"(50,00 – 30000) mPa s"}],"search_en":"Medical devices: emulsions, creams, ointments, toothpastes, adhesives, denture creams, foams, glycerine, liquids, drops, gels, syrups, shampoos Dynamic viscosity Brookfield method (using a rotational viscometer) Range PB-5/LK, wyd.5 z dnia 13.01.2022 W","technique_en":"Brookfield method (using a rotational viscometer)","test_object_en":"Medical devices: emulsions, creams, ointments, toothpastes, adhesives, denture creams, foams, glycerine, liquids, drops, gels, syrups, shampoos","methodology_zh":"动力粘度","parameters_zh":[{"name":"范围","range":"(50,00 – 30000) mPa s"}],"search_zh":"医疗器械：乳剂、乳膏、软膏、牙膏、胶粘剂、义齿粘固剂、泡沫、甘油、溶液、滴剂、凝胶、糖浆、洗发剂 动力粘度 范围 PB-5/LK, wyd.5 z dnia 13.01.2022 W","test_object_zh":"医疗器械：乳剂、乳膏、软膏、牙膏、胶粘剂、义齿粘固剂、泡沫、甘油、溶液、滴剂、凝胶、糖浆、洗发剂"},{"_id":"6a82c6ff884ede9a1b2c2af3","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Wyroby medyczne: emulsje, kremy, maści, pasty do zębów, kleje, kremy do protez, pianki, gliceryna, płyny, krople, żele, syropy, szampony","methodology":"Masa netto","parameters":[{"name":"Zakres","range":"(1 – 3000) g"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Masa netto\nZakres (1 – 3000) g\nMetoda wagowa","reference":"PB-6/LK, wyd.6 z dnia 13.01.2022 W","norm_bases":["PB-6/LK, wyd.6 z dnia 13.01.2022 W"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby medyczne: emulsje, kremy, maści, pasty do zębów, kleje, kremy do protez, pianki, gliceryna, płyny, krople, żele, syropy, szampony Masa netto\nZakres (1 – 3000) g\nMetoda wagowa PB-6/LK, wyd.6 z dnia 13.01.2022 W Wyroby medyczne: emulsje, kremy, masci, pasty do zebow, kleje, kremy do protez, pianki, gliceryna, plyny, krople, zele, syropy, szampony Masa netto\nZakres (1 – 3000) g\nMetoda wagowa PB-6/LK, wyd.6 z dnia 13.01.2022 W","categories":["other"],"row_index":423,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net weight","parameters_en":[{"name":"Range","range":"(1 – 3000) g"}],"search_en":"Medical devices: emulsions, creams, ointments, toothpastes, adhesives, denture creams, foams, glycerine, liquids, drops, gels, syrups, shampoos Net weight Gravimetric method Range PB-6/LK, wyd.6 z dnia 13.01.2022 W","technique_en":"Gravimetric method","test_object_en":"Medical devices: emulsions, creams, ointments, toothpastes, adhesives, denture creams, foams, glycerine, liquids, drops, gels, syrups, shampoos","parameters_zh":[{"name":"范围","range":"(1 – 3000) g"}],"search_zh":"医疗器械：乳剂、乳膏、软膏、牙膏、胶粘剂、义齿粘固剂、泡沫、甘油、溶液、滴剂、凝胶、糖浆、洗发剂 净重 重量法 范围 PB-6/LK, wyd.6 z dnia 13.01.2022 W","technique_zh":"重量法","methodology_zh":"净重","test_object_zh":"医疗器械：乳剂、乳膏、软膏、牙膏、胶粘剂、义齿粘固剂、泡沫、甘油、溶液、滴剂、凝胶、糖浆、洗发剂"},{"_id":"6a82c6ff884ede9a1b2c2af4","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Wyroby medyczne: emulsje, kremy, maści, pasty do zębów, kleje, kremy do protez, pianki, gliceryna, płyny, krople, żele, syropy, szampony","methodology":"Objętość netto","parameters":[{"name":"Zakres","range":"(1 – 2000) ml"}],"technique":"Metoda objętościowa","techniques":["Metoda objętościowa"],"computed":[],"activity":"Objętość netto\nZakres (1 – 2000) ml\nMetoda objętościowa","reference":"PB-6/LK, wyd.6 z dnia 13.01.2022 W","norm_bases":["PB-6/LK, wyd.6 z dnia 13.01.2022 W"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby medyczne: emulsje, kremy, maści, pasty do zębów, kleje, kremy do protez, pianki, gliceryna, płyny, krople, żele, syropy, szampony Objętość netto\nZakres (1 – 2000) ml\nMetoda objętościowa PB-6/LK, wyd.6 z dnia 13.01.2022 W Wyroby medyczne: emulsje, kremy, masci, pasty do zebow, kleje, kremy do protez, pianki, gliceryna, plyny, krople, zele, syropy, szampony Objetosc netto\nZakres (1 – 2000) ml\nMetoda objetosciowa PB-6/LK, wyd.6 z dnia 13.01.2022 W","categories":["other"],"row_index":424,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net volume","parameters_en":[{"name":"Range","range":"(1 – 2000) ml"}],"search_en":"Medical devices: emulsions, creams, ointments, toothpastes, adhesives, denture creams, foams, glycerine, liquids, drops, gels, syrups, shampoos Net volume Volumetric method Range PB-6/LK, wyd.6 z dnia 13.01.2022 W","technique_en":"Volumetric method","test_object_en":"Medical devices: emulsions, creams, ointments, toothpastes, adhesives, denture creams, foams, glycerine, liquids, drops, gels, syrups, shampoos","parameters_zh":[{"name":"范围","range":"(1 – 2000) ml"}],"search_zh":"医疗器械：乳剂、乳膏、软膏、牙膏、胶粘剂、义齿粘固剂、泡沫、甘油、溶液、滴剂、凝胶、糖浆、洗发剂 容量法 范围 PB-6/LK, wyd.6 z dnia 13.01.2022 W","technique_zh":"容量法","test_object_zh":"医疗器械：乳剂、乳膏、软膏、牙膏、胶粘剂、义齿粘固剂、泡沫、甘油、溶液、滴剂、凝胶、糖浆、洗发剂"},{"_id":"6a82c6ff884ede9a1b2c2af5","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Wyroby medyczne: materiały opatrunkowe, materiały medyczne jednorazowe, tabletki, proszki, kapsułki, czopki, sztyfty","methodology":"Masa netto","parameters":[{"name":"Zakres","range":"(1 – 3000) g"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Masa netto\nZakres (1 – 3000) g\nMetoda wagowa","reference":"PB-6/LK, wyd.6 z dnia 13.01.2022 W","norm_bases":["PB-6/LK, wyd.6 z dnia 13.01.2022 W"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby medyczne: materiały opatrunkowe, materiały medyczne jednorazowe, tabletki, proszki, kapsułki, czopki, sztyfty Masa netto\nZakres (1 – 3000) g\nMetoda wagowa PB-6/LK, wyd.6 z dnia 13.01.2022 W Wyroby medyczne: materialy opatrunkowe, materialy medyczne jednorazowe, tabletki, proszki, kapsulki, czopki, sztyfty Masa netto\nZakres (1 – 3000) g\nMetoda wagowa PB-6/LK, wyd.6 z dnia 13.01.2022 W","categories":["materials"],"row_index":425,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net weight","parameters_en":[{"name":"Range","range":"(1 – 3000) g"}],"search_en":"Medical devices: dressing materials, single-use medical materials, tablets, powders, capsules, suppositories, sticks Net weight Gravimetric method Range PB-6/LK, wyd.6 z dnia 13.01.2022 W","technique_en":"Gravimetric method","test_object_en":"Medical devices: dressing materials, single-use medical materials, tablets, powders, capsules, suppositories, sticks","parameters_zh":[{"name":"范围","range":"(1 – 3000) g"}],"search_zh":"医疗器械：敷料、一次性医用材料、片剂、粉剂、胶囊、栓剂、棒剂 净重 重量法 范围 PB-6/LK, wyd.6 z dnia 13.01.2022 W","technique_zh":"重量法","methodology_zh":"净重","test_object_zh":"医疗器械：敷料、一次性医用材料、片剂、粉剂、胶囊、栓剂、棒剂"},{"_id":"6a82c6ff884ede9a1b2c2af6","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Wyroby medyczne: materiały opatrunkowe, materiały medyczne jednorazowe, tabletki, proszki, kapsułki, czopki, sztyfty","methodology":"Wymiary","parameters":[{"name":"Zakres","range":"(0,001 – 50) cm"}],"technique":"Metoda pomiaru długości","techniques":["Metoda pomiaru długości"],"computed":[],"activity":"Wymiary\nZakres (0,001 – 50) cm\nMetoda pomiaru długości","reference":"PB-7/LK, wyd.6 z dnia 13.01.2022 W","norm_bases":["PB-7/LK, wyd.6 z dnia 13.01.2022 W"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby medyczne: materiały opatrunkowe, materiały medyczne jednorazowe, tabletki, proszki, kapsułki, czopki, sztyfty Wymiary\nZakres (0,001 – 50) cm\nMetoda pomiaru długości PB-7/LK, wyd.6 z dnia 13.01.2022 W Wyroby medyczne: materialy opatrunkowe, materialy medyczne jednorazowe, tabletki, proszki, kapsulki, czopki, sztyfty Wymiary\nZakres (0,001 – 50) cm\nMetoda pomiaru dlugosci PB-7/LK, wyd.6 z dnia 13.01.2022 W","categories":["materials"],"row_index":426,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dimensions","parameters_en":[{"name":"Range","range":"(0,001 – 50) cm"}],"search_en":"Medical devices: dressing materials, single-use medical materials, tablets, powders, capsules, suppositories, sticks Dimensions Length measurement method Range PB-7/LK, wyd.6 z dnia 13.01.2022 W","technique_en":"Length measurement method","test_object_en":"Medical devices: dressing materials, single-use medical materials, tablets, powders, capsules, suppositories, sticks","parameters_zh":[{"name":"范围","range":"(0,001 – 50) cm"}],"search_zh":"医疗器械：敷料、一次性医用材料、片剂、粉剂、胶囊、栓剂、棒剂 尺寸 范围 PB-7/LK, wyd.6 z dnia 13.01.2022 W","methodology_zh":"尺寸","test_object_zh":"医疗器械：敷料、一次性医用材料、片剂、粉剂、胶囊、栓剂、棒剂"},{"_id":"6a82c6ff884ede9a1b2c2af7","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Wyroby medyczne: materiały opatrunkowe, materiały medyczne jednorazowe, tabletki, proszki, kapsułki, czopki, sztyfty","methodology":"Gramatura (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gramatura (z obliczeń)","reference":"PB-7/LK, wyd.6 z dnia 13.01.2022 W","norm_bases":["PB-7/LK, wyd.6 z dnia 13.01.2022 W"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby medyczne: materiały opatrunkowe, materiały medyczne jednorazowe, tabletki, proszki, kapsułki, czopki, sztyfty Gramatura (z obliczeń) PB-7/LK, wyd.6 z dnia 13.01.2022 W Wyroby medyczne: materialy opatrunkowe, materialy medyczne jednorazowe, tabletki, proszki, kapsulki, czopki, sztyfty Gramatura (z obliczen) PB-7/LK, wyd.6 z dnia 13.01.2022 W","categories":["materials"],"row_index":427,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Grammage (calculated)","search_en":"Medical devices: dressing materials, single-use medical materials, tablets, powders, capsules, suppositories, sticks Grammage (calculated) PB-7/LK, wyd.6 z dnia 13.01.2022 W","test_object_en":"Medical devices: dressing materials, single-use medical materials, tablets, powders, capsules, suppositories, sticks","search_zh":"医疗器械：敷料、一次性医用材料、片剂、粉剂、胶囊、栓剂、棒剂 PB-7/LK, wyd.6 z dnia 13.01.2022 W","test_object_zh":"医疗器械：敷料、一次性医用材料、片剂、粉剂、胶囊、栓剂、棒剂"},{"_id":"6a82c6ff884ede9a1b2c2af8","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura"},{"name":"Zakres","range":"(1,0 – 85,0)oC"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (1,0 – 85,0)oC","reference":"PN-ISO 5667-5:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-4 :2017-10 | PB-49/P wyd. 4 z dnia 10.01.2022 Ł, M","norm_bases":["PN-ISO 5667-5:2017-10","PN-EN ISO 5667-6:2016-12","PN-ISO 5667-4 :2017-10","PB-49/P wyd. 4 z dnia 10.01.2022 Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (1,0 – 85,0)oC PN-ISO 5667-5:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-4 :2017-10 | PB-49/P wyd. 4 z dnia 10.01.2022 Ł, M Woda, woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (1,0 – 85,0)oC PN-ISO 5667-5:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-4 :2017-10 | PB-49/P wyd. 4 z dnia 10.01.2022 L, M","categories":["water"],"row_index":428,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature"},{"name":"Range","range":"(1,0 – 85,0)oC"}],"search_en":"Water, water intended for human consumption Sampling for chemical and physical testing Temperature Range PN-ISO 5667-5:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-4 :2017-10 | PB-49/P wyd. 4 z dnia 10.01.2022 Ł, M","test_object_en":"Water, water intended for human consumption","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"温度"},{"name":"范围","range":"(1,0 – 85,0)oC"}],"search_zh":"水、生活饮用水 化学与物理检测用样品采集 温度 范围 PN-ISO 5667-5:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-4 :2017-10 | PB-49/P wyd. 4 z dnia 10.01.2022 Ł, M","test_object_zh":"水、生活饮用水"},{"_id":"6a82c6ff884ede9a1b2c2af9","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych, Pobieranie próbek do badań w kierunku bakterii z rodzaju Legionella spp.","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych, Pobieranie próbek do badań w kierunku bakterii z rodzaju Legionella spp.","reference":"PN-EN ISO 19458:2007 Ł, M","norm_bases":["PN-EN ISO 19458:2007 Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych, Pobieranie próbek do badań w kierunku bakterii z rodzaju Legionella spp. PN-EN ISO 19458:2007 Ł, M Woda, woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych, Pobieranie probek do badan w kierunku bakterii z rodzaju Legionella spp. PN-EN ISO 19458:2007 L, M","categories":["microbiology","water"],"row_index":429,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing, Sampling for testing for bacteria of the genus Legionella spp.","search_en":"Water, water intended for human consumption Sampling for microbiological testing, Sampling for testing for bacteria of the genus Legionella spp. PN-EN ISO 19458:2007 Ł, M","test_object_en":"Water, water intended for human consumption","search_zh":"水、生活饮用水 PN-EN ISO 19458:2007 Ł, M","test_object_zh":"水、生活饮用水"},{"_id":"6a82c6ff884ede9a1b2c2afa","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Obiekty z obszaru produkcji żywności","methodology":"Pobieranie próbek z powierzchni metodą płytek kontaktowych do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek z powierzchni metodą płytek kontaktowych do badań mikrobiologicznych","reference":"PN-EN ISO 18593:2018-08 | PN-A-82055-19:2000 Ł, M","norm_bases":["PN-EN ISO 18593:2018-08","PN-A-82055-19:2000 Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Obiekty z obszaru produkcji żywności Pobieranie próbek z powierzchni metodą płytek kontaktowych do badań mikrobiologicznych PN-EN ISO 18593:2018-08 | PN-A-82055-19:2000 Ł, M Obiekty z obszaru produkcji zywnosci Pobieranie probek z powierzchni metoda plytek kontaktowych do badan mikrobiologicznych PN-EN ISO 18593:2018-08 | PN-A-82055-19:2000 L, M","categories":["food","microbiology"],"row_index":430,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling from surfaces by the contact plate method for microbiological testing","search_en":"Objects from the food production area Sampling from surfaces by the contact plate method for microbiological testing PN-EN ISO 18593:2018-08 | PN-A-82055-19:2000 Ł, M","test_object_en":"Objects from the food production area","search_zh":"食品生产场所的对象 PN-EN ISO 18593:2018-08 | PN-A-82055-19:2000 Ł, M","test_object_zh":"食品生产场所的对象"},{"_id":"6a82c6ff884ede9a1b2c2afb","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Obiekty z obszaru produkcji żywności","methodology":"Pobieranie próbek z powierzchni i rąk metodą wymazową do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek z powierzchni i rąk metodą wymazową do badań mikrobiologicznych","reference":"Ł, M","norm_bases":["Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Obiekty z obszaru produkcji żywności Pobieranie próbek z powierzchni i rąk metodą wymazową do badań mikrobiologicznych Ł, M Obiekty z obszaru produkcji zywnosci Pobieranie probek z powierzchni i rak metoda wymazowa do badan mikrobiologicznych L, M","categories":["food","microbiology"],"row_index":431,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling from surfaces and hands by the swab method for microbiological testing","search_en":"Objects from the food production area Sampling from surfaces and hands by the swab method for microbiological testing Ł, M","test_object_en":"Objects from the food production area","search_zh":"食品生产场所的对象 Ł, M","test_object_zh":"食品生产场所的对象"},{"_id":"6a82c6ff884ede9a1b2c2afc","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów niezwiązanych z żywnością","methodology":"Pobieranie próbek z powierzchni metodą płytek kontaktowych do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek z powierzchni metodą płytek kontaktowych do badań mikrobiologicznych","reference":"PN-EN ISO 18593:2018-08 Ł, M","norm_bases":["PN-EN ISO 18593:2018-08 Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z obszarów niezwiązanych z żywnością Pobieranie próbek z powierzchni metodą płytek kontaktowych do badań mikrobiologicznych PN-EN ISO 18593:2018-08 Ł, M Probki srodowiskowe z obszarow niezwiazanych z zywnoscia Pobieranie probek z powierzchni metoda plytek kontaktowych do badan mikrobiologicznych PN-EN ISO 18593:2018-08 L, M","categories":["food","environment","microbiology"],"row_index":432,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling from surfaces by the contact plate method for microbiological testing","search_en":"Environmental samples from non-food areas Sampling from surfaces by the contact plate method for microbiological testing PN-EN ISO 18593:2018-08 Ł, M","test_object_en":"Environmental samples from non-food areas"},{"_id":"6a82c6ff884ede9a1b2c2afd","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów niezwiązanych z żywnością","methodology":"Pobieranie próbek z powierzchni i rąk metodą wymazową do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek z powierzchni i rąk metodą wymazową do badań mikrobiologicznych","reference":"Ł, M","norm_bases":["Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z obszarów niezwiązanych z żywnością Pobieranie próbek z powierzchni i rąk metodą wymazową do badań mikrobiologicznych Ł, M Probki srodowiskowe z obszarow niezwiazanych z zywnoscia Pobieranie probek z powierzchni i rak metoda wymazowa do badan mikrobiologicznych L, M","categories":["food","environment","microbiology"],"row_index":433,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling from surfaces and hands by the swab method for microbiological testing","search_en":"Environmental samples from non-food areas Sampling from surfaces and hands by the swab method for microbiological testing Ł, M","test_object_en":"Environmental samples from non-food areas"},{"_id":"6a82c6ff884ede9a1b2c2afe","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Higiena uboju - tusze / półtusze zwierząt rzeźnych","methodology":"Pobieranie próbek do badań mikrobiologicznych metodą niszczącą i nieniszczącą","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych metodą niszczącą i nieniszczącą","reference":"PN-ISO 17604:2015-10 Ł, M","norm_bases":["PN-ISO 17604:2015-10 Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Higiena uboju - tusze / półtusze zwierząt rzeźnych Pobieranie próbek do badań mikrobiologicznych metodą niszczącą i nieniszczącą PN-ISO 17604:2015-10 Ł, M Higiena uboju - tusze / poltusze zwierzat rzeznych Pobieranie probek do badan mikrobiologicznych metoda niszczaca i nieniszczaca PN-ISO 17604:2015-10 L, M","categories":["microbiology"],"row_index":434,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing by the destructive and non-destructive method","search_en":"Slaughter hygiene - carcasses / half-carcasses of slaughter animals Sampling for microbiological testing by the destructive and non-destructive method PN-ISO 17604:2015-10 Ł, M","test_object_en":"Slaughter hygiene - carcasses / half-carcasses of slaughter animals"},{"_id":"6a82c6ff884ede9a1b2c2aff","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Higiena uboju - tusze drobiowe","methodology":"Pobieranie próbek do badań mikrobiologicznych metodą niszczącą","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych metodą niszczącą","reference":"Rozporządzenie Komisji (WE) nr 2073/2005 z dnia 15 listopada 2005 r. z późn. zm. Ł, M","norm_bases":["Rozporządzenie Komisji (WE) nr 2073/2005 z dnia 15 listopada 2005 r. z późn. zm. Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Higiena uboju - tusze drobiowe Pobieranie próbek do badań mikrobiologicznych metodą niszczącą Rozporządzenie Komisji (WE) nr 2073/2005 z dnia 15 listopada 2005 r. z późn. zm. Ł, M Higiena uboju - tusze drobiowe Pobieranie probek do badan mikrobiologicznych metoda niszczaca Rozporzadzenie Komisji (WE) nr 2073/2005 z dnia 15 listopada 2005 r. z pozn. zm. L, M","categories":["microbiology"],"row_index":435,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing by the destructive method","search_en":"Slaughter hygiene - poultry carcasses Sampling for microbiological testing by the destructive method Rozporządzenie Komisji (WE) nr 2073/2005 z dnia 15 listopada 2005 r. z późn. zm. Ł, M","test_object_en":"Slaughter hygiene - poultry carcasses"},{"_id":"6a82c6ff884ede9a1b2c2b00","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda powierzchniowa","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 Ł, M","norm_bases":["PN-EN ISO 19458:2007 Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda powierzchniowa Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Ł, M Woda powierzchniowa Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 L, M","categories":["water","microbiology"],"row_index":436,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Surface water Sampling for microbiological testing PN-EN ISO 19458:2007 Ł, M","test_object_en":"Surface water","methodology_zh":"微生物检测用样品采集","search_zh":"地表水 微生物检测用样品采集 PN-EN ISO 19458:2007 Ł, M","test_object_zh":"地表水"},{"_id":"6a82c6ff884ede9a1b2c2b01","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda podziemna","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Poziom lustra wody","parameters":[{"name":"Zakres","range":"(0,1 – 100) m. p.p.t."},{"name":"Temperatura"},{"name":"Zakres","range":"(1,0 – 85,0)oC"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Poziom lustra wody\nZakres:\nZakres (0,1 – 100) m. p.p.t.\nTemperatura\nZakres (1,0 – 85,0)oC","reference":"PN-ISO 5667-11:2017-10 | PB-109/P wyd. 7 z dnia 10.01.2022 | PB-49/P wyd. 4 z dnia 10.01.2022 Ł, M","norm_bases":["PN-ISO 5667-11:2017-10","PB-109/P wyd. 7 z dnia 10.01.2022","PB-49/P wyd. 4 z dnia 10.01.2022 Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda podziemna Pobieranie próbek do badań chemicznych i fizycznych Poziom lustra wody\nZakres:\nZakres (0,1 – 100) m. p.p.t.\nTemperatura\nZakres (1,0 – 85,0)oC PN-ISO 5667-11:2017-10 | PB-109/P wyd. 7 z dnia 10.01.2022 | PB-49/P wyd. 4 z dnia 10.01.2022 Ł, M Woda podziemna Pobieranie probek do badan chemicznych i fizycznych Poziom lustra wody\nZakres:\nZakres (0,1 – 100) m. p.p.t.\nTemperatura\nZakres (1,0 – 85,0)oC PN-ISO 5667-11:2017-10 | PB-109/P wyd. 7 z dnia 10.01.2022 | PB-49/P wyd. 4 z dnia 10.01.2022 L, M","categories":["water"],"row_index":437,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing Water table level","parameters_en":[{"name":"Range","range":"(0,1 – 100) m. p.p.t."},{"name":"Temperature"},{"name":"Range","range":"(1,0 – 85,0)oC"}],"search_en":"Groundwater Sampling for chemical and physical testing Water table level Range Temperature Range PN-ISO 5667-11:2017-10 | PB-109/P wyd. 7 z dnia 10.01.2022 | PB-49/P wyd. 4 z dnia 10.01.2022 Ł, M","test_object_en":"Groundwater","parameters_zh":[{"name":"范围","range":"(0,1 – 100) m. p.p.t."},{"name":"温度"},{"name":"范围","range":"(1,0 – 85,0)oC"}],"search_zh":"地下水 范围 温度 范围 PN-ISO 5667-11:2017-10 | PB-109/P wyd. 7 z dnia 10.01.2022 | PB-49/P wyd. 4 z dnia 10.01.2022 Ł, M","test_object_zh":"地下水"},{"_id":"6a82c6ff884ede9a1b2c2b02","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura próbki wody","parameters":[{"name":"Zakres","range":"(1,0 – 85,0)oC"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura próbki wody\nZakres (1,0 – 85,0)oC","reference":"PB-164/P wyd. 5 z dnia 10.01.2022 | PB-49/P wyd. 4 z dnia 10.01.2022 Ł, M","norm_bases":["PB-164/P wyd. 5 z dnia 10.01.2022","PB-49/P wyd. 4 z dnia 10.01.2022 Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Pobieranie próbek do badań chemicznych i fizycznych Temperatura próbki wody\nZakres (1,0 – 85,0)oC PB-164/P wyd. 5 z dnia 10.01.2022 | PB-49/P wyd. 4 z dnia 10.01.2022 Ł, M Woda na plywalniach Pobieranie probek do badan chemicznych i fizycznych Temperatura probki wody\nZakres (1,0 – 85,0)oC PB-164/P wyd. 5 z dnia 10.01.2022 | PB-49/P wyd. 4 z dnia 10.01.2022 L, M","categories":["water"],"row_index":438,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample","parameters_en":[{"name":"Range","range":"(1,0 – 85,0)oC"}],"search_en":"Swimming pool water Sampling for chemical and physical testing Temperature of the water sample Range PB-164/P wyd. 5 z dnia 10.01.2022 | PB-49/P wyd. 4 z dnia 10.01.2022 Ł, M","test_object_en":"Swimming pool water","parameters_zh":[{"name":"范围","range":"(1,0 – 85,0)oC"}],"search_zh":"游泳池水 范围 PB-164/P wyd. 5 z dnia 10.01.2022 | PB-49/P wyd. 4 z dnia 10.01.2022 Ł, M","test_object_zh":"游泳池水"},{"_id":"6a82c6ff884ede9a1b2c2b03","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Płyn do dializ, woda do dializ","methodology":"Pobieranie próbek do badań chemicznych, fizycznych i mikrobiologicznych Temperatura próbki wody","parameters":[{"name":"Zakres","range":"(1,0 – 85,0)oC"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych i mikrobiologicznych Temperatura próbki wody\nZakres (1,0 – 85,0)oC","reference":"PB-157/P wyd. 4 z dnia 10.01.2022 | PB-49/P wyd. 4 z dnia 10.01.2022 Ł, M","norm_bases":["PB-157/P wyd. 4 z dnia 10.01.2022","PB-49/P wyd. 4 z dnia 10.01.2022 Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Płyn do dializ, woda do dializ Pobieranie próbek do badań chemicznych, fizycznych i mikrobiologicznych Temperatura próbki wody\nZakres (1,0 – 85,0)oC PB-157/P wyd. 4 z dnia 10.01.2022 | PB-49/P wyd. 4 z dnia 10.01.2022 Ł, M Plyn do dializ, woda do dializ Pobieranie probek do badan chemicznych, fizycznych i mikrobiologicznych Temperatura probki wody\nZakres (1,0 – 85,0)oC PB-157/P wyd. 4 z dnia 10.01.2022 | PB-49/P wyd. 4 z dnia 10.01.2022 L, M","categories":["water","microbiology"],"row_index":439,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical, physical and microbiological testing Temperature of the water sample","parameters_en":[{"name":"Range","range":"(1,0 – 85,0)oC"}],"search_en":"Dialysis fluid, dialysis water Sampling for chemical, physical and microbiological testing Temperature of the water sample Range PB-157/P wyd. 4 z dnia 10.01.2022 | PB-49/P wyd. 4 z dnia 10.01.2022 Ł, M","test_object_en":"Dialysis fluid, dialysis water","parameters_zh":[{"name":"范围","range":"(1,0 – 85,0)oC"}],"search_zh":"范围 PB-157/P wyd. 4 z dnia 10.01.2022 | PB-49/P wyd. 4 z dnia 10.01.2022 Ł, M"},{"_id":"6a82c6ff884ede9a1b2c2b04","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Ścieki, wody opadowe i roztopowe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura"},{"name":"Zakres","range":"(1,0 – 85,0)°C"}],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (1,0 – 85,0)°C\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11 | PB-49/P wyd. 4 z dnia 10.01.2022 Ł, M","norm_bases":["PN-ISO 5667-10:2021-11","PB-49/P wyd. 4 z dnia 10.01.2022 Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, wody opadowe i roztopowe Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (1,0 – 85,0)°C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PB-49/P wyd. 4 z dnia 10.01.2022 Ł, M Scieki, wody opadowe i roztopowe Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (1,0 – 85,0)°C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PB-49/P wyd. 4 z dnia 10.01.2022 L, M","categories":["water"],"row_index":440,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature"},{"name":"Range","range":"(1,0 – 85,0)°C"}],"search_en":"Wastewater, rainwater and snowmelt water Sampling for chemical and physical testing Manual method; Automatic method Temperature Range PN-ISO 5667-10:2021-11 | PB-49/P wyd. 4 z dnia 10.01.2022 Ł, M","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater, rainwater and snowmelt water","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"温度"},{"name":"范围","range":"(1,0 – 85,0)°C"}],"search_zh":"废水、雨水与融雪水 化学与物理检测用样品采集 手动法；自动法 温度 范围 PN-ISO 5667-10:2021-11 | PB-49/P wyd. 4 z dnia 10.01.2022 Ł, M","technique_zh":"手动法；自动法","test_object_zh":"废水、雨水与融雪水"},{"_id":"6a82c6ff884ede9a1b2c2b05","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych\nMetoda manualna","reference":"PN-EN ISO 19458:2007 Ł, M","norm_bases":["PN-EN ISO 19458:2007 Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań mikrobiologicznych\nMetoda manualna PN-EN ISO 19458:2007 Ł, M Scieki Pobieranie probek do badan mikrobiologicznych\nMetoda manualna PN-EN ISO 19458:2007 L, M","categories":["water","microbiology"],"row_index":441,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Wastewater Sampling for microbiological testing Manual method PN-EN ISO 19458:2007 Ł, M","technique_en":"Manual method","test_object_en":"Wastewater","methodology_zh":"微生物检测用样品采集","search_zh":"污水 微生物检测用样品采集 手工法 PN-EN ISO 19458:2007 Ł, M","test_object_zh":"污水","technique_zh":"手工法"},{"_id":"6a82c6ff884ede9a1b2c2b06","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych, biologicznych i mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych, biologicznych i mikrobiologicznych","reference":"PN-EN ISO 5667-13:2011 | PB-167/P wyd. 4 z dnia 10.01.2022 Ł, M","norm_bases":["PN-EN ISO 5667-13:2011","PB-167/P wyd. 4 z dnia 10.01.2022 Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Pobieranie próbek do badań chemicznych i fizycznych, biologicznych i mikrobiologicznych PN-EN ISO 5667-13:2011 | PB-167/P wyd. 4 z dnia 10.01.2022 Ł, M Osady sciekowe Pobieranie probek do badan chemicznych i fizycznych, biologicznych i mikrobiologicznych PN-EN ISO 5667-13:2011 | PB-167/P wyd. 4 z dnia 10.01.2022 L, M","categories":["water","microbiology"],"row_index":442,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical, biological and microbiological testing","search_en":"Sewage sludge Sampling for chemical and physical, biological and microbiological testing PN-EN ISO 5667-13:2011 | PB-167/P wyd. 4 z dnia 10.01.2022 Ł, M","test_object_en":"Sewage sludge","search_zh":"污泥 PN-EN ISO 5667-13:2011 | PB-167/P wyd. 4 z dnia 10.01.2022 Ł, M","test_object_zh":"污泥"},{"_id":"6a82c6ff884ede9a1b2c2b07","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Osady denne","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 4364:2005 Ł, M","norm_bases":["PN-ISO 4364:2005 Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady denne Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 4364:2005 Ł, M Osady denne Pobieranie probek do badan chemicznych i fizycznych PN-ISO 4364:2005 L, M","categories":["water"],"row_index":443,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Bottom sediments Sampling for chemical and physical testing PN-ISO 4364:2005 Ł, M","test_object_en":"Bottom sediments","methodology_zh":"化学与物理检测用样品采集","search_zh":"底泥 化学与物理检测用样品采集 PN-ISO 4364:2005 Ł, M","test_object_zh":"底泥"},{"_id":"6a82c6ff884ede9a1b2c2b08","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gleba","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009 Ł, M","norm_bases":["PN-ISO 10381-4:2007","PN-ISO 10381-5:2009 Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009 Ł, M Gleba Pobieranie probek do badan chemicznych i fizycznych PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009 L, M","categories":["environment"],"row_index":444,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Soil Sampling for chemical and physical testing PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009 Ł, M","test_object_en":"Soil","methodology_zh":"化学与物理检测用样品采集","search_zh":"土壤 化学与物理检测用样品采集 PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009 Ł, M","test_object_zh":"土壤"},{"_id":"6a82c6ff884ede9a1b2c2b09","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Kompost, biomasa, stabilizat, nawóz organiczny","methodology":"Pobieranie próbek do badań chemicznych, fizycznych, biologicznych i mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych, biologicznych i mikrobiologicznych","reference":"PB-51/P wyd. 2 z dnia 10.01.2022 Ł, M","norm_bases":["PB-51/P wyd. 2 z dnia 10.01.2022 Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kompost, biomasa, stabilizat, nawóz organiczny Pobieranie próbek do badań chemicznych, fizycznych, biologicznych i mikrobiologicznych PB-51/P wyd. 2 z dnia 10.01.2022 Ł, M Kompost, biomasa, stabilizat, nawoz organiczny Pobieranie probek do badan chemicznych, fizycznych, biologicznych i mikrobiologicznych PB-51/P wyd. 2 z dnia 10.01.2022 L, M","categories":["microbiology"],"row_index":445,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical, physical, biological and microbiological testing","search_en":"Compost, biomass, stabilised waste, organic fertiliser Sampling for chemical, physical, biological and microbiological testing PB-51/P wyd. 2 z dnia 10.01.2022 Ł, M","test_object_en":"Compost, biomass, stabilised waste, organic fertiliser"},{"_id":"6a82c6ff884ede9a1b2c2b0a","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Środki wspomagające uprawę roślin, w tym: środki poprawiające właściwości gleby, stymulatory wzrostu, podłoża do upraw","methodology":"Pobieranie próbek do badań chemicznych, fizycznych i mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych i mikrobiologicznych","reference":"PN-EN 12579:2024-09 Ł, M","norm_bases":["PN-EN 12579:2024-09 Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środki wspomagające uprawę roślin, w tym: środki poprawiające właściwości gleby, stymulatory wzrostu, podłoża do upraw Pobieranie próbek do badań chemicznych, fizycznych i mikrobiologicznych PN-EN 12579:2024-09 Ł, M Srodki wspomagajace uprawe roslin, w tym: srodki poprawiajace wlasciwosci gleby, stymulatory wzrostu, podloza do upraw Pobieranie probek do badan chemicznych, fizycznych i mikrobiologicznych PN-EN 12579:2024-09 L, M","categories":["microbiology"],"row_index":446,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical, physical and microbiological testing","search_en":"Plant cultivation aids, including: soil improvers, growth stimulants, growing media Sampling for chemical, physical and microbiological testing PN-EN 12579:2024-09 Ł, M","test_object_en":"Plant cultivation aids, including: soil improvers, growth stimulants, growing media","methodology_zh":"用于化学、物理与微生物检验的采样","search_zh":"用于化学、物理与微生物检验的采样 PN-EN 12579:2024-09 Ł, M"},{"_id":"6a82c6ff884ede9a1b2c2b0b","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Mieszanki mineralno-asfaltowe: destrukt asfaltowy","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PB-168/P wyd. 5 z dnia 10.01.2022 Ł, M","norm_bases":["PB-168/P wyd. 5 z dnia 10.01.2022 Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno-asfaltowe: destrukt asfaltowy Pobieranie próbek do badań chemicznych i fizycznych PB-168/P wyd. 5 z dnia 10.01.2022 Ł, M Mieszanki mineralno-asfaltowe: destrukt asfaltowy Pobieranie probek do badan chemicznych i fizycznych PB-168/P wyd. 5 z dnia 10.01.2022 L, M","categories":["other"],"row_index":447,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Bituminous mixtures: reclaimed asphalt Sampling for chemical and physical testing PB-168/P wyd. 5 z dnia 10.01.2022 Ł, M","test_object_en":"Bituminous mixtures: reclaimed asphalt","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 PB-168/P wyd. 5 z dnia 10.01.2022 Ł, M"},{"_id":"6a82c6ff884ede9a1b2c2b0c","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Powietrze","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":"Metoda sedymentacyjna, zderzeniowa","techniques":["Metoda sedymentacyjna, zderzeniowa"],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych\nMetoda sedymentacyjna, zderzeniowa","reference":"PB-05/P wyd. 3 z dnia 10.01.2022 Ł, M","norm_bases":["PB-05/P wyd. 3 z dnia 10.01.2022 Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Powietrze Pobieranie próbek do badań mikrobiologicznych\nMetoda sedymentacyjna, zderzeniowa PB-05/P wyd. 3 z dnia 10.01.2022 Ł, M Powietrze Pobieranie probek do badan mikrobiologicznych\nMetoda sedymentacyjna, zderzeniowa PB-05/P wyd. 3 z dnia 10.01.2022 L, M","categories":["environment","microbiology"],"row_index":448,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Air Sampling for microbiological testing PB-05/P wyd. 3 z dnia 10.01.2022 Ł, M","test_object_en":"Air","methodology_zh":"微生物检测用样品采集","search_zh":"空气 微生物检测用样品采集 PB-05/P wyd. 3 z dnia 10.01.2022 Ł, M","test_object_zh":"空气"},{"_id":"6a82c6ff884ede9a1b2c2b0d","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Środki do zwalczania śliskości zimowej","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PB-249/P wyd. 3 z dnia 10.01.2022 Ł, M","norm_bases":["PB-249/P wyd. 3 z dnia 10.01.2022 Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środki do zwalczania śliskości zimowej Pobieranie próbek do badań chemicznych i fizycznych PB-249/P wyd. 3 z dnia 10.01.2022 Ł, M Srodki do zwalczania sliskosci zimowej Pobieranie probek do badan chemicznych i fizycznych PB-249/P wyd. 3 z dnia 10.01.2022 L, M","categories":["other"],"row_index":449,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Winter de-icing and anti-skid materials Sampling for chemical and physical testing PB-249/P wyd. 3 z dnia 10.01.2022 Ł, M","test_object_en":"Winter de-icing and anti-skid materials","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 PB-249/P wyd. 3 z dnia 10.01.2022 Ł, M"},{"_id":"6a82c6ff884ede9a1b2c2b0e","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"(3,0 – 12,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (3,0 – 12,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012 Ł, M","norm_bases":["PN-EN ISO 10523:2012 Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki pH\nZakres (3,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Ł, M Woda, scieki pH\nZakres (3,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 L, M","categories":["water"],"row_index":450,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"(3,0 – 12,0)"}],"search_en":"Water, wastewater pH Potentiometric method Range PN-EN ISO 10523:2012 Ł, M","technique_en":"Potentiometric method","test_object_en":"Water, wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(3,0 – 12,0)"}],"search_zh":"水、废水 pH 值 电位法 范围 PN-EN ISO 10523:2012 Ł, M","technique_zh":"电位法","test_object_zh":"水、废水"},{"_id":"6a82c6ff884ede9a1b2c2b0f","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Przewodność elektryczna właściwa Zakres: (10 – 19999) μS/cm","parameters":[],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa Zakres: (10 – 19999) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999 Ł, M","norm_bases":["PN-EN 27888:1999 Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Przewodność elektryczna właściwa Zakres: (10 – 19999) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Ł, M Woda, scieki Przewodnosc elektryczna wlasciwa Zakres: (10 – 19999) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 L, M","categories":["water"],"row_index":451,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity Range: (10 – 19999) μS/cm","search_en":"Water, wastewater Electrical conductivity Range: (10 – 19999) μS/cm Conductometric method PN-EN 27888:1999 Ł, M","technique_en":"Conductometric method","test_object_en":"Water, wastewater","search_zh":"水、废水 电导法 PN-EN 27888:1999 Ł, M","technique_zh":"电导法","test_object_zh":"水、废水"},{"_id":"6a82c6ff884ede9a1b2c2b10","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,05 – 6,0) mg/l"},{"name":"Stężenie chloru ogólnego"},{"name":"Zakres","range":"(0,05 – 6,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres:\nZakres (0,05 – 6,0) mg/l\nStężenie chloru ogólnego\nZakres (0,05 – 6,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-25/P wyd. 7 z dnia 10.01.2022 Ł, M","norm_bases":["PB-25/P wyd. 7 z dnia 10.01.2022 Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chloru wolnego\nZakres:\nZakres (0,05 – 6,0) mg/l\nStężenie chloru ogólnego\nZakres (0,05 – 6,0) mg/l\nMetoda spektrofotometryczna PB-25/P wyd. 7 z dnia 10.01.2022 Ł, M Woda, scieki Stezenie chloru wolnego\nZakres:\nZakres (0,05 – 6,0) mg/l\nStezenie chloru ogolnego\nZakres (0,05 – 6,0) mg/l\nMetoda spektrofotometryczna PB-25/P wyd. 7 z dnia 10.01.2022 L, M","categories":["water"],"row_index":452,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,05 – 6,0) mg/l"},{"name":"Total chlorine concentration"},{"name":"Range","range":"(0,05 – 6,0) mg/l"}],"search_en":"Water, wastewater Free chlorine concentration Spectrophotometric method Range Total chlorine concentration Range PB-25/P wyd. 7 z dnia 10.01.2022 Ł, M","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 6,0) mg/l"},{"name":"总氯浓度"},{"name":"范围","range":"(0,05 – 6,0) mg/l"}],"search_zh":"水、废水 游离氯浓度 分光光度法 范围 总氯浓度 范围 PB-25/P wyd. 7 z dnia 10.01.2022 Ł, M","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a82c6ff884ede9a1b2c2b11","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chloru związanego (stężenie chloramin) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chloru związanego (stężenie chloramin) (z obliczeń)","reference":"Ł, M","norm_bases":["Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chloru związanego (stężenie chloramin) (z obliczeń) Ł, M Woda, scieki Stezenie chloru zwiazanego (stezenie chloramin) (z obliczen) L, M","categories":["water"],"row_index":453,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Combined chlorine concentration (chloramine concentration) (calculated)","search_en":"Water, wastewater Combined chlorine concentration (chloramine concentration) (calculated) Ł, M","test_object_en":"Water, wastewater","search_zh":"水、废水 Ł, M","test_object_zh":"水、废水"},{"_id":"6a82c6ff884ede9a1b2c2b12","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,50 – 25) mg/l"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,50 – 25) mg/l\nMetoda elektrochemiczna","reference":"PN-EN ISO 5814:2013-04 Ł, M","norm_bases":["PN-EN ISO 5814:2013-04 Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie tlenu rozpuszczonego\nZakres (0,50 – 25) mg/l\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04 Ł, M Woda, scieki Stezenie tlenu rozpuszczonego\nZakres (0,50 – 25) mg/l\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04 L, M","categories":["water"],"row_index":454,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(0,50 – 25) mg/l"}],"search_en":"Water, wastewater Dissolved oxygen concentration Electrochemical method Range PN-EN ISO 5814:2013-04 Ł, M","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,50 – 25) mg/l"}],"search_zh":"水、废水 溶解氧浓度 电化学法 范围 PN-EN ISO 5814:2013-04 Ł, M","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"溶解氧浓度"},{"_id":"6a82c6ff884ede9a1b2c2b13","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie ozonu","parameters":[{"name":"Zakres","range":"(0,03 – 0,6) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ozonu\nZakres (0,03 – 0,6) mg/l\nMetoda spektrofotometryczna","reference":"PB-26/P wyd. 4 z dnia 10.01.2022 Ł, M","norm_bases":["PB-26/P wyd. 4 z dnia 10.01.2022 Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie ozonu\nZakres (0,03 – 0,6) mg/l\nMetoda spektrofotometryczna PB-26/P wyd. 4 z dnia 10.01.2022 Ł, M Woda, scieki Stezenie ozonu\nZakres (0,03 – 0,6) mg/l\nMetoda spektrofotometryczna PB-26/P wyd. 4 z dnia 10.01.2022 L, M","categories":["water"],"row_index":455,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ozone concentration","parameters_en":[{"name":"Range","range":"(0,03 – 0,6) mg/l"}],"search_en":"Water, wastewater Ozone concentration Spectrophotometric method Range PB-26/P wyd. 4 z dnia 10.01.2022 Ł, M","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,03 – 0,6) mg/l"}],"search_zh":"水、废水 臭氧浓度 分光光度法 范围 PB-26/P wyd. 4 z dnia 10.01.2022 Ł, M","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"臭氧浓度"},{"_id":"6a82c6ff884ede9a1b2c2b14","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie kwasu izocyjanurowego","parameters":[{"name":"Zakres","range":"(5 - 200) mg/l"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"computed":[],"activity":"Stężenie kwasu izocyjanurowego\nZakres (5 - 200) mg/l\nMetoda turbidymetryczna","reference":"PB-27/P wyd. 3 z dnia 10.01.2022 | na podstawie metody HACH nr 8139 Ł, M","norm_bases":["PB-27/P wyd. 3 z dnia 10.01.2022","na podstawie metody HACH nr 8139 Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie kwasu izocyjanurowego\nZakres (5 - 200) mg/l\nMetoda turbidymetryczna PB-27/P wyd. 3 z dnia 10.01.2022 | na podstawie metody HACH nr 8139 Ł, M Woda Stezenie kwasu izocyjanurowego\nZakres (5 - 200) mg/l\nMetoda turbidymetryczna PB-27/P wyd. 3 z dnia 10.01.2022 | na podstawie metody HACH nr 8139 L, M","categories":["water"],"row_index":456,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Isocyanuric acid concentration","parameters_en":[{"name":"Range","range":"(5 - 200) mg/l"}],"search_en":"Water Isocyanuric acid concentration Turbidimetric method Range PB-27/P wyd. 3 z dnia 10.01.2022 | na podstawie metody HACH nr 8139 Ł, M","technique_en":"Turbidimetric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(5 - 200) mg/l"}],"search_zh":"水 异氰尿酸浓度 浊度法 范围 PB-27/P wyd. 3 z dnia 10.01.2022 | na podstawie metody HACH nr 8139 Ł, M","test_object_zh":"水","technique_zh":"浊度法","methodology_zh":"异氰尿酸浓度"},{"_id":"6a82c6ff884ede9a1b2c2b15","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Woda","methodology":"Potencjał utleniająco-redukujący (redoks)","parameters":[{"name":"Zakres","range":"(- 400 – 1000 ) mV"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Potencjał utleniająco-redukujący (redoks)\nZakres (- 400 – 1000 ) mV\nMetoda potencjometryczna","reference":"PB-247/P wyd. 4 z dnia 10.01.2022 Ł, M","norm_bases":["PB-247/P wyd. 4 z dnia 10.01.2022 Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Potencjał utleniająco-redukujący (redoks)\nZakres (- 400 – 1000 ) mV\nMetoda potencjometryczna PB-247/P wyd. 4 z dnia 10.01.2022 Ł, M Woda Potencjal utleniajaco-redukujacy (redoks)\nZakres (- 400 – 1000 ) mV\nMetoda potencjometryczna PB-247/P wyd. 4 z dnia 10.01.2022 L, M","categories":["water"],"row_index":457,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxidation-reduction potential (redox)","parameters_en":[{"name":"Range","range":"(- 400 – 1000 ) mV"}],"search_en":"Water Oxidation-reduction potential (redox) Potentiometric method Range PB-247/P wyd. 4 z dnia 10.01.2022 Ł, M","technique_en":"Potentiometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(- 400 – 1000 ) mV"}],"search_zh":"水 氧化还原电位（redox） 电位法 范围 PB-247/P wyd. 4 z dnia 10.01.2022 Ł, M","technique_zh":"电位法","test_object_zh":"水","methodology_zh":"氧化还原电位（redox）"},{"_id":"6a82c6ff884ede9a1b2c2b16","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gazy składowiskowe","methodology":"Prędkość przepływu","parameters":[{"name":"Zakres","range":"(0,1 – 10) m/s"}],"technique":"Metoda termoanemometryczna","techniques":["Metoda termoanemometryczna"],"computed":[],"activity":"Prędkość przepływu\nZakres (0,1 – 10) m/s\nMetoda termoanemometryczna","reference":"PB-171/P wyd. 5 z dnia 10.01.2022 Ł, M","norm_bases":["PB-171/P wyd. 5 z dnia 10.01.2022 Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy składowiskowe Prędkość przepływu\nZakres (0,1 – 10) m/s\nMetoda termoanemometryczna PB-171/P wyd. 5 z dnia 10.01.2022 Ł, M Gazy skladowiskowe Predkosc przeplywu\nZakres (0,1 – 10) m/s\nMetoda termoanemometryczna PB-171/P wyd. 5 z dnia 10.01.2022 L, M","categories":["other"],"row_index":458,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Flow velocity","parameters_en":[{"name":"Range","range":"(0,1 – 10) m/s"}],"search_en":"Landfill gases Flow velocity Thermoanemometric method Range PB-171/P wyd. 5 z dnia 10.01.2022 Ł, M","technique_en":"Thermoanemometric method","test_object_en":"Landfill gases","parameters_zh":[{"name":"范围","range":"(0,1 – 10) m/s"}],"search_zh":"填埋场气体 流速 热线风速仪法 范围 PB-171/P wyd. 5 z dnia 10.01.2022 Ł, M","test_object_zh":"填埋场气体","methodology_zh":"流速","technique_zh":"热线风速仪法"},{"_id":"6a82c6ff884ede9a1b2c2b17","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gazy składowiskowe","methodology":"Stężenie: O2, CO2, CH4","parameters":[{"name":"O2","range":"(0,5 – 21)%"},{"name":"CO2","range":"(0,3 – 40,0)%"},{"name":"CH4","range":"(0,3 – 70,0)%"}],"technique":"Metoda elektrochemiczna; Metoda absorpcji promieniowania IR","techniques":["Metoda elektrochemiczna","Metoda absorpcji promieniowania IR"],"computed":[],"activity":"Stężenie: O2, CO2, CH4\nZakres:\nO2 (0,5 – 21)%\nCO2 (0,3 – 40,0)%\nCH4 (0,3 – 70,0)%\nMetoda elektrochemiczna; Metoda absorpcji promieniowania IR","reference":"Ł, M","norm_bases":["Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy składowiskowe Stężenie: O2, CO2, CH4\nZakres:\nO2 (0,5 – 21)%\nCO2 (0,3 – 40,0)%\nCH4 (0,3 – 70,0)%\nMetoda elektrochemiczna; Metoda absorpcji promieniowania IR Ł, M Gazy skladowiskowe Stezenie: O2, CO2, CH4\nZakres:\nO2 (0,5 – 21)%\nCO2 (0,3 – 40,0)%\nCH4 (0,3 – 70,0)%\nMetoda elektrochemiczna; Metoda absorpcji promieniowania IR L, M","categories":["other"],"row_index":459,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of: O2, CO2, CH4","parameters_en":[{"name":"O2","range":"(0,5 – 21)%"},{"name":"CO2","range":"(0,3 – 40,0)%"},{"name":"CH4","range":"(0,3 – 70,0)%"}],"search_en":"Landfill gases Concentration of: O2, CO2, CH4 Electrochemical method; IR radiation absorption method O2 CO2 CH4 Ł, M","technique_en":"Electrochemical method; IR radiation absorption method","test_object_en":"Landfill gases","parameters_zh":[{"name":"O2","range":"(0,5 – 21)%"},{"name":"CO2","range":"(0,3 – 40,0)%"},{"name":"CH4","range":"(0,3 – 70,0)%"}],"search_zh":"填埋场气体 O2 CO2 Ł, M","test_object_zh":"填埋场气体"},{"_id":"6a82c6ff884ede9a1b2c2b18","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Gazy składowiskowe","methodology":"Emisja: CO2, CH4 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja: CO2, CH4 (z obliczeń)","reference":"Ł, M","norm_bases":["Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy składowiskowe Emisja: CO2, CH4 (z obliczeń) Ł, M Gazy skladowiskowe Emisja: CO2, CH4 (z obliczen) L, M","categories":["environment"],"row_index":460,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission: CO2, CH4 (calculated)","search_en":"Landfill gases Emission: CO2, CH4 (calculated) Ł, M","test_object_en":"Landfill gases","search_zh":"填埋场气体 Ł, M","test_object_zh":"填埋场气体"},{"_id":"6a82c6ff884ede9a1b2c2b19","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady DAB-11: Osady i odpady mineralne (I), Odpady budowalne (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI)","methodology":"Pobieranie próbek do badań chemicznych, fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych","reference":"PB-168/P wyd. 5 z dnia 10.01.2022 Ł, M","norm_bases":["PB-168/P wyd. 5 z dnia 10.01.2022 Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":"Pobieranie próbek wykonywane dla celów obszaru regulowanego: - Rozporządzenie Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277). - Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz.U. 2017, poz. 2490) - Rozporządzenie Ministra Środowiska z dnia 06 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz.U. 2015, poz. 257) - Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. 2015, poz. 132). - Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. 2015, poz. 796). - Rozporządzenie Ministra Klimatu z dnia 24 grudnia 2019 r. w sprawie warunków uznania odpadów za posiadające właściwości zakaźne oraz sposobu ustalania tych właściwości (Dz.U. 2020, poz. 3) - Rozporządzenie Ministra Klimatu i Środowiska z dnia 23 grudnia 2021 r. w sprawie określenia szczegółowych warunków utraty statusu odpadów dla odpadów destruktu asfaltowego - Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz. U. 2023, poz. 56 z późn. zm.) - Rozporządzenie Ministra Rozwoju z dnia 21 stycznia 2016 r. w sprawie wymagań dotyczących prowadzenia procesu termicznego przekształcania odpadów oraz sposobów postępowania z odpadami powstałymi w wyniku tego procesu (Dz.U. 2016 poz. 108) DAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.","flexible":false,"search_text":"Odpady DAB-11: Osady i odpady mineralne (I), Odpady budowalne (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) Pobieranie próbek do badań chemicznych, fizycznych PB-168/P wyd. 5 z dnia 10.01.2022 Ł, M Odpady DAB-11: Osady i odpady mineralne (I), Odpady budowalne (III), Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV), Odpady z przetwarzania odpadow (VI), Osady z procesow przemyslowych (VII), Osady sciekowe (IX), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI), Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) Pobieranie probek do badan chemicznych, fizycznych PB-168/P wyd. 5 z dnia 10.01.2022 L, M","categories":["environment","water","food"],"row_index":461,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical, physical testing","search_en":"Sampling for chemical, physical testing PB-168/P wyd. 5 z dnia 10.01.2022 Ł, M","methodology_zh":"用于化学、物理检验的采样","search_zh":"用于化学、物理检验的采样 PB-168/P wyd. 5 z dnia 10.01.2022 Ł, M"},{"_id":"6a82c6ff884ede9a1b2c2b1a","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady DAB-11: Osady i odpady mineralne (I), Odpady z przetwarzania odpadów (VI), Osady ściekowe (IX), Żużle, popioły i pyły paleniskowe (XI)","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"Ł, M","norm_bases":["Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":"Pobieranie próbek wykonywane dla celów obszaru regulowanego: - Rozporządzenie Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277). - Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz.U. 2017, poz. 2490) - Rozporządzenie Ministra Środowiska z dnia 06 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz.U. 2015, poz. 257) - Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. 2015, poz. 132). - Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. 2015, poz. 796). - Rozporządzenie Ministra Klimatu z dnia 24 grudnia 2019 r. w sprawie warunków uznania odpadów za posiadające właściwości zakaźne oraz sposobu ustalania tych właściwości (Dz.U. 2020, poz. 3) - Rozporządzenie Ministra Klimatu i Środowiska z dnia 23 grudnia 2021 r. w sprawie określenia szczegółowych warunków utraty statusu odpadów dla odpadów destruktu asfaltowego - Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz. U. 2023, poz. 56 z późn. zm.) - Rozporządzenie Ministra Rozwoju z dnia 21 stycznia 2016 r. w sprawie wymagań dotyczących prowadzenia procesu termicznego przekształcania odpadów oraz sposobów postępowania z odpadami powstałymi w wyniku tego procesu (Dz.U. 2016 poz. 108) DAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.","flexible":false,"search_text":"Odpady DAB-11: Osady i odpady mineralne (I), Odpady z przetwarzania odpadów (VI), Osady ściekowe (IX), Żużle, popioły i pyły paleniskowe (XI) Pobieranie próbek do badań mikrobiologicznych Ł, M Odpady DAB-11: Osady i odpady mineralne (I), Odpady z przetwarzania odpadow (VI), Osady sciekowe (IX), Zuzle, popioly i pyly paleniskowe (XI) Pobieranie probek do badan mikrobiologicznych L, M","categories":["environment","water","microbiology"],"row_index":462,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Sampling for microbiological testing Ł, M","methodology_zh":"微生物检测用样品采集","search_zh":"微生物检测用样品采集 Ł, M"},{"_id":"6a82c6ff884ede9a1b2c2b1b","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady DAB-11: Tworzywa sztuczne (XXV), Drewno (XXVI)","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PB-168/P wyd. 5 z dnia 10.01.2022 Ł, M","norm_bases":["PB-168/P wyd. 5 z dnia 10.01.2022 Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":"Pobieranie próbek wykonywane dla celów obszaru regulowanego: - Rozporządzenie Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277). - Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz.U. 2017, poz. 2490) - Rozporządzenie Ministra Środowiska z dnia 06 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz.U. 2015, poz. 257) - Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. 2015, poz. 132). - Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. 2015, poz. 796). - Rozporządzenie Ministra Klimatu z dnia 24 grudnia 2019 r. w sprawie warunków uznania odpadów za posiadające właściwości zakaźne oraz sposobu ustalania tych właściwości (Dz.U. 2020, poz. 3) - Rozporządzenie Ministra Klimatu i Środowiska z dnia 23 grudnia 2021 r. w sprawie określenia szczegółowych warunków utraty statusu odpadów dla odpadów destruktu asfaltowego - Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz. U. 2023, poz. 56 z późn. zm.) - Rozporządzenie Ministra Rozwoju z dnia 21 stycznia 2016 r. w sprawie wymagań dotyczących prowadzenia procesu termicznego przekształcania odpadów oraz sposobów postępowania z odpadami powstałymi w wyniku tego procesu (Dz.U. 2016 poz. 108) DAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.","flexible":false,"search_text":"Odpady DAB-11: Tworzywa sztuczne (XXV), Drewno (XXVI) Pobieranie próbek do badań chemicznych i fizycznych PB-168/P wyd. 5 z dnia 10.01.2022 Ł, M Odpady DAB-11: Tworzywa sztuczne (XXV), Drewno (XXVI) Pobieranie probek do badan chemicznych i fizycznych PB-168/P wyd. 5 z dnia 10.01.2022 L, M","categories":["environment","materials"],"row_index":463,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Sampling for chemical and physical testing PB-168/P wyd. 5 z dnia 10.01.2022 Ł, M","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 PB-168/P wyd. 5 z dnia 10.01.2022 Ł, M"},{"_id":"6a82c6ff884ede9a1b2c2b1c","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"OdpadyDAB-11: Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","methodology":"Pobieranie próbek do badań chemicznych, fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych","reference":"Ł, M","norm_bases":["Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":"Pobieranie próbek wykonywane dla celów obszaru regulowanego: - Rozporządzenie Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277). - Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz.U. 2017, poz. 2490) - Rozporządzenie Ministra Środowiska z dnia 06 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz.U. 2015, poz. 257) - Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. 2015, poz. 132). - Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. 2015, poz. 796). - Rozporządzenie Ministra Klimatu z dnia 24 grudnia 2019 r. w sprawie warunków uznania odpadów za posiadające właściwości zakaźne oraz sposobu ustalania tych właściwości (Dz.U. 2020, poz. 3) - Rozporządzenie Ministra Klimatu i Środowiska z dnia 23 grudnia 2021 r. w sprawie określenia szczegółowych warunków utraty statusu odpadów dla odpadów destruktu asfaltowego - Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz. U. 2023, poz. 56 z późn. zm.) - Rozporządzenie Ministra Rozwoju z dnia 21 stycznia 2016 r. w sprawie wymagań dotyczących prowadzenia procesu termicznego przekształcania odpadów oraz sposobów postępowania z odpadami powstałymi w wyniku tego procesu (Dz.U. 2016 poz. 108) DAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.","flexible":false,"search_text":"OdpadyDAB-11: Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Pobieranie próbek do badań chemicznych, fizycznych Ł, M OdpadyDAB-11: Skory i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Pobieranie probek do badan chemicznych, fizycznych L, M","categories":["environment","water"],"row_index":464,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical, physical testing","search_en":"WasteDAB-11: Leather and textiles (XXVII), Other municipal waste and waste derived from municipal waste, including mixed waste, and other waste from wastewater treatment and water treatment (XXVIII) Sampling for chemical, physical testing Ł, M","test_object_en":"WasteDAB-11: Leather and textiles (XXVII), Other municipal waste and waste derived from municipal waste, including mixed waste, and other waste from wastewater treatment and water treatment (XXVIII)","methodology_zh":"用于化学、物理检验的采样","search_zh":"用于化学、物理检验的采样 Ł, M"},{"_id":"6a82c6ff884ede9a1b2c2b1d","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady o) kod: 16 81 02,","methodology":"Pobieranie próbek do badań chemicznych, fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych","reference":"Ł, M","norm_bases":["Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":"Pobieranie próbek wykonywane dla celów obszaru regulowanego: - Rozporządzenie Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277). - Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz.U. 2017, poz. 2490) - Rozporządzenie Ministra Środowiska z dnia 06 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz.U. 2015, poz. 257) - Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. 2015, poz. 132). - Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. 2015, poz. 796). - Rozporządzenie Ministra Klimatu z dnia 24 grudnia 2019 r. w sprawie warunków uznania odpadów za posiadające właściwości zakaźne oraz sposobu ustalania tych właściwości (Dz.U. 2020, poz. 3) - Rozporządzenie Ministra Klimatu i Środowiska z dnia 23 grudnia 2021 r. w sprawie określenia szczegółowych warunków utraty statusu odpadów dla odpadów destruktu asfaltowego - Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz. U. 2023, poz. 56 z późn. zm.) - Rozporządzenie Ministra Rozwoju z dnia 21 stycznia 2016 r. w sprawie wymagań dotyczących prowadzenia procesu termicznego przekształcania odpadów oraz sposobów postępowania z odpadami powstałymi w wyniku tego procesu (Dz.U. 2016 poz. 108) O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady o) kod: 16 81 02, Pobieranie próbek do badań chemicznych, fizycznych Ł, M Odpady o) kod: 16 81 02, Pobieranie probek do badan chemicznych, fizycznych L, M","categories":["environment"],"row_index":465,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical, physical testing","search_en":"Sampling for chemical, physical testing Ł, M","methodology_zh":"用于化学、物理检验的采样","search_zh":"用于化学、物理检验的采样 Ł, M"},{"_id":"6a82c6ff884ede9a1b2c2b1e","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"OdpadyDAB-11: Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"Ł, M","norm_bases":["Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":"Pobieranie próbek wykonywane dla celów obszaru regulowanego: - Rozporządzenie Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277). - Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz.U. 2017, poz. 2490) - Rozporządzenie Ministra Środowiska z dnia 06 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz.U. 2015, poz. 257) - Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. 2015, poz. 132). - Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. 2015, poz. 796). - Rozporządzenie Ministra Klimatu z dnia 24 grudnia 2019 r. w sprawie warunków uznania odpadów za posiadające właściwości zakaźne oraz sposobu ustalania tych właściwości (Dz.U. 2020, poz. 3) - Rozporządzenie Ministra Klimatu i Środowiska z dnia 23 grudnia 2021 r. w sprawie określenia szczegółowych warunków utraty statusu odpadów dla odpadów destruktu asfaltowego - Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz. U. 2023, poz. 56 z późn. zm.) - Rozporządzenie Ministra Rozwoju z dnia 21 stycznia 2016 r. w sprawie wymagań dotyczących prowadzenia procesu termicznego przekształcania odpadów oraz sposobów postępowania z odpadami powstałymi w wyniku tego procesu (Dz.U. 2016 poz. 108) DAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.","flexible":false,"search_text":"OdpadyDAB-11: Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Pobieranie próbek do badań mikrobiologicznych Ł, M OdpadyDAB-11: Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Pobieranie probek do badan mikrobiologicznych L, M","categories":["environment","water","microbiology"],"row_index":466,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"WasteDAB-11: Other municipal waste and waste derived from municipal waste, including mixed waste, and other waste from wastewater treatment and water treatment (XXVIII) Sampling for microbiological testing Ł, M","test_object_en":"WasteDAB-11: Other municipal waste and waste derived from municipal waste, including mixed waste, and other waste from wastewater treatment and water treatment (XXVIII)","methodology_zh":"微生物检测用样品采集","search_zh":"微生物检测用样品采集 Ł, M"},{"_id":"6a82c6ff884ede9a1b2c2b1f","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady o) kod: 16 81 02,","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"Ł, M","norm_bases":["Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":"Pobieranie próbek wykonywane dla celów obszaru regulowanego: - Rozporządzenie Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277). - Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz.U. 2017, poz. 2490) - Rozporządzenie Ministra Środowiska z dnia 06 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz.U. 2015, poz. 257) - Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. 2015, poz. 132). - Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. 2015, poz. 796). - Rozporządzenie Ministra Klimatu z dnia 24 grudnia 2019 r. w sprawie warunków uznania odpadów za posiadające właściwości zakaźne oraz sposobu ustalania tych właściwości (Dz.U. 2020, poz. 3) - Rozporządzenie Ministra Klimatu i Środowiska z dnia 23 grudnia 2021 r. w sprawie określenia szczegółowych warunków utraty statusu odpadów dla odpadów destruktu asfaltowego - Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz. U. 2023, poz. 56 z późn. zm.) - Rozporządzenie Ministra Rozwoju z dnia 21 stycznia 2016 r. w sprawie wymagań dotyczących prowadzenia procesu termicznego przekształcania odpadów oraz sposobów postępowania z odpadami powstałymi w wyniku tego procesu (Dz.U. 2016 poz. 108) O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady o) kod: 16 81 02, Pobieranie próbek do badań mikrobiologicznych Ł, M Odpady o) kod: 16 81 02, Pobieranie probek do badan mikrobiologicznych L, M","categories":["environment","microbiology"],"row_index":467,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Sampling for microbiological testing Ł, M","methodology_zh":"微生物检测用样品采集","search_zh":"微生物检测用样品采集 Ł, M"},{"_id":"6a82c6ff884ede9a1b2c2b20","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady DAB-11: Szlamy i odpady płynne (V)","methodology":"Pobieranie próbek do badań chemicznych, fizycznych i mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych i mikrobiologicznych","reference":"PB-168/P wyd. 5 z dnia 10.01.2022 Ł, M","norm_bases":["PB-168/P wyd. 5 z dnia 10.01.2022 Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":"Pobieranie próbek wykonywane dla celów obszaru regulowanego: - Rozporządzenie Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277). - Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz.U. 2017, poz. 2490) - Rozporządzenie Ministra Środowiska z dnia 06 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz.U. 2015, poz. 257) - Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. 2015, poz. 132). - Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. 2015, poz. 796). - Rozporządzenie Ministra Klimatu z dnia 24 grudnia 2019 r. w sprawie warunków uznania odpadów za posiadające właściwości zakaźne oraz sposobu ustalania tych właściwości (Dz.U. 2020, poz. 3) - Rozporządzenie Ministra Klimatu i Środowiska z dnia 23 grudnia 2021 r. w sprawie określenia szczegółowych warunków utraty statusu odpadów dla odpadów destruktu asfaltowego - Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz. U. 2023, poz. 56 z późn. zm.) - Rozporządzenie Ministra Rozwoju z dnia 21 stycznia 2016 r. w sprawie wymagań dotyczących prowadzenia procesu termicznego przekształcania odpadów oraz sposobów postępowania z odpadami powstałymi w wyniku tego procesu (Dz.U. 2016 poz. 108) DAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.","flexible":false,"search_text":"Odpady DAB-11: Szlamy i odpady płynne (V) Pobieranie próbek do badań chemicznych, fizycznych i mikrobiologicznych PB-168/P wyd. 5 z dnia 10.01.2022 Ł, M Odpady DAB-11: Szlamy i odpady plynne (V) Pobieranie probek do badan chemicznych, fizycznych i mikrobiologicznych PB-168/P wyd. 5 z dnia 10.01.2022 L, M","categories":["environment","microbiology"],"row_index":468,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical, physical and microbiological testing","search_en":"Sampling for chemical, physical and microbiological testing PB-168/P wyd. 5 z dnia 10.01.2022 Ł, M","methodology_zh":"用于化学、物理与微生物检验的采样","search_zh":"用于化学、物理与微生物检验的采样 PB-168/P wyd. 5 z dnia 10.01.2022 Ł, M"},{"_id":"6a82c6ff884ede9a1b2c2b21","lab_id":"69ad52a3de79e566650fb590","country":"PL","accr_number":"AB 1095","accr_body":"PCA","test_object":"Odpady DAB-11: Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI)","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PB-168/P wyd. 5 z dnia 10.01.2022 Ł, M","norm_bases":["PB-168/P wyd. 5 z dnia 10.01.2022 Ł, M"],"lab_section":null,"lab_address":null,"regulatory_area":"Pobieranie próbek wykonywane dla celów obszaru regulowanego: - Rozporządzenie Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277). - Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz.U. 2017, poz. 2490) - Rozporządzenie Ministra Środowiska z dnia 06 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz.U. 2015, poz. 257) - Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. 2015, poz. 132). - Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. 2015, poz. 796). - Rozporządzenie Ministra Klimatu z dnia 24 grudnia 2019 r. w sprawie warunków uznania odpadów za posiadające właściwości zakaźne oraz sposobu ustalania tych właściwości (Dz.U. 2020, poz. 3) - Rozporządzenie Ministra Klimatu i Środowiska z dnia 23 grudnia 2021 r. w sprawie określenia szczegółowych warunków utraty statusu odpadów dla odpadów destruktu asfaltowego - Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz. U. 2023, poz. 56 z późn. zm.) - Rozporządzenie Ministra Rozwoju z dnia 21 stycznia 2016 r. w sprawie wymagań dotyczących prowadzenia procesu termicznego przekształcania odpadów oraz sposobów postępowania z odpadami powstałymi w wyniku tego procesu (Dz.U. 2016 poz. 108) DAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.","flexible":false,"search_text":"Odpady DAB-11: Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI) Pobieranie próbek do badań chemicznych i fizycznych PB-168/P wyd. 5 z dnia 10.01.2022 Ł, M Odpady DAB-11: Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI) Pobieranie probek do badan chemicznych i fizycznych PB-168/P wyd. 5 z dnia 10.01.2022 L, M","categories":["environment"],"row_index":469,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Sampling for chemical and physical testing PB-168/P wyd. 5 z dnia 10.01.2022 Ł, M","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 PB-168/P wyd. 5 z dnia 10.01.2022 Ł, M"}],"has_pdf":true}