{"lab":{"_id":"69ad52a3de79e566650fb588","accr_number":"AB 1089","country":"PL","accr_body":"PCA","address":"LABORATORIUM OCHRONY ŚRODOWISKA, ul. Harcerska 15, 45-118 Opole","categories":["environment","petro"],"city":"Opole","imported_at":"2026-03-08T10:42:43.265Z","methods_count":81,"name":"ECO LOGISTYKA Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1089.pdf"],"scope_summary":"","search_text":"eco logistyka sp. z o.o. laboratorium ochrony środowiska, ul. harcerska 15, 45-118 opole petro other materials pharma environment electronics metrology","status":"active","updated_at":"2026-03-08T14:50:16.137Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-14T13:12:04.053Z","parse_date":"2026-08-14T13:12:04.053Z","parse_source":"agent-claude-code","email_confidence":"high","email_mx":true,"email_source":"https://www.ecosa.pl/kontakt/eco-logistyka.html","fields_of_testing":[{"codes":"A/5; A/13","pl":"Badania akustyczne – obiekty budowlane (pomieszczenia), maszyny i urządzenia","en":"Acoustic tests of building items, machinery and devices"},{"codes":"C/32","pl":"Badania chemiczne odpadów","en":"Chemical tests of waste"},{"codes":"C/10/P; C/33/P; C/36/P","pl":"Badania chemiczne i pobieranie próbek paliw, środowisko pracy (czynniki szkodliwe - powietrze), gazy (gazy odlotowe),","en":"Chemical tests and sampling of fuels solid, working environment (harmful factors - air) gases (waste gases)"},{"codes":"G/33; G/34; G/36","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe - oświetlenie, hałas), środowisko ogólne (czynniki fizyczne - hałas), gazy odlotowe","en":"Tests concerning environmental engineering (environmental and climatic) - workplace (harmful and nuisance factors – lighting, noise), general environment (physical factors - noise), waste gases"},{"codes":"M/13","pl":"Badania inne – urządzenia odpylające gazy odlotowe","en":"Other tests - air protection equipment"},{"codes":"N/32","pl":"Badania właściwości fizycznych odpadów","en":"Tests of physical properties of waste"},{"codes":"N/10/P; N/33/P; N/36/P","pl":"Badania właściwości fizycznych i pobieranie próbek - paliw, środowisko pracy (czynniki szkodliwe - powietrze), gazy (gazy odlotowe)","en":"Tests of physical properties and sampling of fuels, working environment (harmful factors - air), gases (waste gases)"},{"codes":"P/36","pl":"Pobieranie próbek – gazy (gazy odlotowe)","en":"Sampling of gases (waste gases)"}],"issue":{"no":"24","date":"13.07.2026"},"map_coord":[50.68496,17.919611],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM OCHRONY ŚRODOWISKA","address":"ul. Harcerska 15","city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/14/6df7d069c10a0cfcc0f0d39e56124789/AB%201089.pdf","has_en":true,"category_counts":{"environment":43,"other":18,"petro":18,"materials":4,"metrology":1},"category_scores":{"environment":22.01,"other":3.86,"petro":3.86,"materials":0.19,"metrology":0.01},"has_zh":true},"methods":[{"_id":"6a7f14241995264369d8e49e","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Paliwa stałe – węgiel kamienny","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-G-04502:2014-11 p. 5.3.6","norm_bases":["PN-G-04502:2014-11 p. 5.3.6"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe – węgiel kamienny Pobieranie próbek do badań chemicznych i fizycznych PN-G-04502:2014-11 p. 5.3.6 Paliwa stale – wegiel kamienny Pobieranie probek do badan chemicznych i fizycznych PN-G-04502:2014-11 p. 5.3.6","categories":["petro"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Solid fuels – hard coal Sampling for chemical and physical testing Environmental Protection Laboratory PN-G-04502:2014-11 p. 5.3.6","test_object_en":"Solid fuels – hard coal","methodology_zh":"化学与物理检测用样品采集","search_zh":"固体燃料 — 烟煤 化学与物理检测用样品采集 环境保护实验室 PN-G-04502:2014-11 p. 5.3.6","test_object_zh":"固体燃料 — 烟煤","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e49f","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Paliwa stałe – węgiel kamienny","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(12 000 – 35 000) kJ/kg"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres (12 000 – 35 000) kJ/kg\nMetoda kalorymetryczna","reference":"PN-81/G-04513","norm_bases":["PN-81/G-04513"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe – węgiel kamienny Ciepło spalania\nZakres (12 000 – 35 000) kJ/kg\nMetoda kalorymetryczna PN-81/G-04513 Paliwa stale – wegiel kamienny Cieplo spalania\nZakres (12 000 – 35 000) kJ/kg\nMetoda kalorymetryczna PN-81/G-04513","categories":["petro"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(12 000 – 35 000) kJ/kg"}],"search_en":"Solid fuels – hard coal Gross calorific value Calorimetric method Environmental Protection Laboratory Range PN-81/G-04513","technique_en":"Calorimetric method","test_object_en":"Solid fuels – hard coal","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(12 000 – 35 000) kJ/kg"}],"search_zh":"固体燃料 — 烟煤 高位发热量 量热法 环境保护实验室 范围 PN-81/G-04513","technique_zh":"量热法","test_object_zh":"固体燃料 — 烟煤","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4a0","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Paliwa stałe – węgiel kamienny","methodology":"Wartość opałowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość opałowa (z obliczeń)","reference":"PN-81/G-04513","norm_bases":["PN-81/G-04513"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe – węgiel kamienny Wartość opałowa (z obliczeń) PN-81/G-04513 Paliwa stale – wegiel kamienny Wartosc opalowa (z obliczen) PN-81/G-04513","categories":["petro"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Net calorific value (calculated)","search_en":"Solid fuels – hard coal Net calorific value (calculated) Environmental Protection Laboratory PN-81/G-04513","test_object_en":"Solid fuels – hard coal","methodology_zh":"低位发热量（计算值）","search_zh":"固体燃料 — 烟煤 低位发热量（计算值） 环境保护实验室 PN-81/G-04513","test_object_zh":"固体燃料 — 烟煤","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4a1","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Paliwa stałe – węgiel kamienny","methodology":"Zawartość wilgoci przemijającej","parameters":[{"name":"Zakres","range":"(1,0 – 30,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci przemijającej\nZakres (1,0 – 30,0) %\nMetoda wagowa","reference":"PN-80/G-04511 | PN-G-04611:2020-06","norm_bases":["PN-80/G-04511","PN-G-04611:2020-06"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe – węgiel kamienny Zawartość wilgoci przemijającej\nZakres (1,0 – 30,0) %\nMetoda wagowa PN-80/G-04511 | PN-G-04611:2020-06 Paliwa stale – wegiel kamienny Zawartosc wilgoci przemijajacej\nZakres (1,0 – 30,0) %\nMetoda wagowa PN-80/G-04511 | PN-G-04611:2020-06","categories":["petro"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Free moisture content","parameters_en":[{"name":"Range","range":"(1,0 – 30,0) %"}],"search_en":"Solid fuels – hard coal Free moisture content Gravimetric method Environmental Protection Laboratory Range PN-80/G-04511 | PN-G-04611:2020-06","technique_en":"Gravimetric method","test_object_en":"Solid fuels – hard coal","parameters_zh":[{"name":"范围","range":"(1,0 – 30,0) %"}],"search_zh":"固体燃料 — 烟煤 外在水分含量 重量法 环境保护实验室 范围 PN-80/G-04511 | PN-G-04611:2020-06","technique_zh":"重量法","test_object_zh":"固体燃料 — 烟煤","lab_section_zh":"环境保护实验室","methodology_zh":"外在水分含量"},{"_id":"6a7f14241995264369d8e4a2","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Paliwa stałe – węgiel kamienny","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,2 – 10,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,2 – 10,0) %\nMetoda wagowa","reference":"PN-80/G-04511 | PN-G-04611:2020-06","norm_bases":["PN-80/G-04511","PN-G-04611:2020-06"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe – węgiel kamienny Zawartość wilgoci w próbce analitycznej\nZakres (0,2 – 10,0) %\nMetoda wagowa PN-80/G-04511 | PN-G-04611:2020-06 Paliwa stale – wegiel kamienny Zawartosc wilgoci w probce analitycznej\nZakres (0,2 – 10,0) %\nMetoda wagowa PN-80/G-04511 | PN-G-04611:2020-06","categories":["petro"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,2 – 10,0) %"}],"search_en":"Solid fuels – hard coal Moisture content in the analytical sample Gravimetric method Environmental Protection Laboratory Range PN-80/G-04511 | PN-G-04611:2020-06","technique_en":"Gravimetric method","test_object_en":"Solid fuels – hard coal","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,2 – 10,0) %"}],"search_zh":"固体燃料 — 烟煤 分析样品水分含量 重量法 环境保护实验室 范围 PN-80/G-04511 | PN-G-04611:2020-06","technique_zh":"重量法","test_object_zh":"固体燃料 — 烟煤","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4a3","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Paliwa stałe – węgiel kamienny","methodology":"Zawartość wilgoci w węglu powietrznosuchym","parameters":[{"name":"Zakres","range":"(0,2 – 10,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w węglu powietrznosuchym\nZakres (0,2 – 10,0) %\nMetoda wagowa","reference":"PN-80/G-04511","norm_bases":["PN-80/G-04511"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe – węgiel kamienny Zawartość wilgoci w węglu powietrznosuchym\nZakres (0,2 – 10,0) %\nMetoda wagowa PN-80/G-04511 Paliwa stale – wegiel kamienny Zawartosc wilgoci w weglu powietrznosuchym\nZakres (0,2 – 10,0) %\nMetoda wagowa PN-80/G-04511","categories":["petro"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Moisture content in air-dried coal","parameters_en":[{"name":"Range","range":"(0,2 – 10,0) %"}],"search_en":"Solid fuels – hard coal Moisture content in air-dried coal Gravimetric method Environmental Protection Laboratory Range PN-80/G-04511","technique_en":"Gravimetric method","test_object_en":"Solid fuels – hard coal","parameters_zh":[{"name":"范围","range":"(0,2 – 10,0) %"}],"search_zh":"固体燃料 — 烟煤 重量法 环境保护实验室 范围 PN-80/G-04511","technique_zh":"重量法","test_object_zh":"固体燃料 — 烟煤","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4a4","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Paliwa stałe – węgiel kamienny","methodology":"Zawartość wilgoci całkowitej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wilgoci całkowitej (z obliczeń)","reference":"PN-80/G-04511 | PN-G-04611:2020-06","norm_bases":["PN-80/G-04511","PN-G-04611:2020-06"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe – węgiel kamienny Zawartość wilgoci całkowitej (z obliczeń) PN-80/G-04511 | PN-G-04611:2020-06 Paliwa stale – wegiel kamienny Zawartosc wilgoci calkowitej (z obliczen) PN-80/G-04511 | PN-G-04611:2020-06","categories":["petro"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Total moisture content (calculated)","search_en":"Solid fuels – hard coal Total moisture content (calculated) Environmental Protection Laboratory PN-80/G-04511 | PN-G-04611:2020-06","test_object_en":"Solid fuels – hard coal","search_zh":"固体燃料 — 烟煤 全水分含量（计算值） 环境保护实验室 PN-80/G-04511 | PN-G-04611:2020-06","test_object_zh":"固体燃料 — 烟煤","methodology_zh":"全水分含量（计算值）","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4a5","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Paliwa stałe – węgiel kamienny","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,10 – 3,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,10 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001","norm_bases":["PN-G-04584:2001"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe – węgiel kamienny Zawartość siarki całkowitej\nZakres (0,10 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 Paliwa stale – wegiel kamienny Zawartosc siarki calkowitej\nZakres (0,10 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001","categories":["petro"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,10 – 3,00) %"}],"search_en":"Solid fuels – hard coal Total sulfur content High-temperature combustion with IR detection Environmental Protection Laboratory Range PN-G-04584:2001","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels – hard coal","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,10 – 3,00) %"}],"search_zh":"固体燃料 — 烟煤 全硫含量 高温燃烧红外检测法 环境保护实验室 范围 PN-G-04584:2001","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料 — 烟煤","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4a6","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Paliwa stałe – węgiel kamienny","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(50,0 – 90,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres (50,0 – 90,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe – węgiel kamienny Zawartość węgla całkowitego\nZakres (50,0 – 90,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale – wegiel kamienny Zawartosc wegla calkowitego\nZakres (50,0 – 90,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(50,0 – 90,0) %"}],"search_en":"Solid fuels – hard coal Total carbon content High-temperature combustion with IR detection Environmental Protection Laboratory Range PN-G-04571:1998","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels – hard coal","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(50,0 – 90,0) %"}],"search_zh":"固体燃料 — 烟煤 总碳含量 高温燃烧红外检测法 环境保护实验室 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料 — 烟煤","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4a7","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Paliwa stałe – węgiel kamienny","methodology":"Zawartość chloru","parameters":[{"name":"Zakres","range":"(0,01 – 1,00) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość chloru\nZakres (0,01 – 1,00) %\nMetoda miareczkowa","reference":"PN-ISO 587:2000 p. 7.2.2","norm_bases":["PN-ISO 587:2000 p. 7.2.2"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe – węgiel kamienny Zawartość chloru\nZakres (0,01 – 1,00) %\nMetoda miareczkowa PN-ISO 587:2000 p. 7.2.2 Paliwa stale – wegiel kamienny Zawartosc chloru\nZakres (0,01 – 1,00) %\nMetoda miareczkowa PN-ISO 587:2000 p. 7.2.2","categories":["petro"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Chlorine content","parameters_en":[{"name":"Range","range":"(0,01 – 1,00) %"}],"search_en":"Solid fuels – hard coal Chlorine content Titrimetric method Environmental Protection Laboratory Range PN-ISO 587:2000 p. 7.2.2","technique_en":"Titrimetric method","test_object_en":"Solid fuels – hard coal","parameters_zh":[{"name":"范围","range":"(0,01 – 1,00) %"}],"search_zh":"固体燃料 — 烟煤 氯含量 滴定法 环境保护实验室 范围 PN-ISO 587:2000 p. 7.2.2","technique_zh":"滴定法","methodology_zh":"氯含量","test_object_zh":"固体燃料 — 烟煤","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4a8","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Paliwa stałe – węgiel kamienny","methodology":"Zawartość części lotnych","parameters":[{"name":"Zakres","range":"(10,00 – 50,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość części lotnych\nZakres (10,00 – 50,00) %\nMetoda wagowa","reference":"PN-G-04516:1998","norm_bases":["PN-G-04516:1998"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe – węgiel kamienny Zawartość części lotnych\nZakres (10,00 – 50,00) %\nMetoda wagowa PN-G-04516:1998 Paliwa stale – wegiel kamienny Zawartosc czesci lotnych\nZakres (10,00 – 50,00) %\nMetoda wagowa PN-G-04516:1998","categories":["petro"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Volatile matter content","parameters_en":[{"name":"Range","range":"(10,00 – 50,00) %"}],"search_en":"Solid fuels – hard coal Volatile matter content Gravimetric method Environmental Protection Laboratory Range PN-G-04516:1998","technique_en":"Gravimetric method","test_object_en":"Solid fuels – hard coal","parameters_zh":[{"name":"范围","range":"(10,00 – 50,00) %"}],"search_zh":"固体燃料 — 烟煤 挥发分含量 重量法 环境保护实验室 范围 PN-G-04516:1998","technique_zh":"重量法","methodology_zh":"挥发分含量","test_object_zh":"固体燃料 — 烟煤","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4a9","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Paliwa stałe – węgiel kamienny","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(1,0 – 40,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu\nZakres (1,0 – 40,0) %\nMetoda wagowa","reference":"PN-ISO 1171:2002","norm_bases":["PN-ISO 1171:2002"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe – węgiel kamienny Zawartość popiołu\nZakres (1,0 – 40,0) %\nMetoda wagowa PN-ISO 1171:2002 Paliwa stale – wegiel kamienny Zawartosc popiolu\nZakres (1,0 – 40,0) %\nMetoda wagowa PN-ISO 1171:2002","categories":["petro"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(1,0 – 40,0) %"}],"search_en":"Solid fuels – hard coal Ash content Gravimetric method Environmental Protection Laboratory Range PN-ISO 1171:2002","technique_en":"Gravimetric method","test_object_en":"Solid fuels – hard coal","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 40,0) %"}],"search_zh":"固体燃料 — 烟煤 灰分含量 重量法 环境保护实验室 范围 PN-ISO 1171:2002","technique_zh":"重量法","test_object_zh":"固体燃料 — 烟煤","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4aa","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Paliwa stałe – węgiel kamienny","methodology":"Zawartość wilgoci pierwszego stopnia (przemijającej)","parameters":[{"name":"Zakres","range":"(2,0 – 35,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci pierwszego stopnia (przemijającej)\nZakres (2,0 – 35,0) %\nMetoda wagowa","reference":"PN-ISO 589:2006","norm_bases":["PN-ISO 589:2006"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe – węgiel kamienny Zawartość wilgoci pierwszego stopnia (przemijającej)\nZakres (2,0 – 35,0) %\nMetoda wagowa PN-ISO 589:2006 Paliwa stale – wegiel kamienny Zawartosc wilgoci pierwszego stopnia (przemijajacej)\nZakres (2,0 – 35,0) %\nMetoda wagowa PN-ISO 589:2006","categories":["petro"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"First-stage (free) moisture content","parameters_en":[{"name":"Range","range":"(2,0 – 35,0) %"}],"search_en":"Solid fuels – hard coal First-stage (free) moisture content Gravimetric method Environmental Protection Laboratory Range PN-ISO 589:2006","technique_en":"Gravimetric method","test_object_en":"Solid fuels – hard coal","parameters_zh":[{"name":"范围","range":"(2,0 – 35,0) %"}],"search_zh":"固体燃料 — 烟煤 第一阶段水分（外在水分）含量 重量法 环境保护实验室 范围 PN-ISO 589:2006","technique_zh":"重量法","test_object_zh":"固体燃料 — 烟煤","lab_section_zh":"环境保护实验室","methodology_zh":"第一阶段水分（外在水分）含量"},{"_id":"6a7f14241995264369d8e4ab","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Paliwa stałe – węgiel kamienny","methodology":"Zawartość wilgoci drugiego stopnia (pozostałej w próbce)","parameters":[{"name":"Zakres","range":"(0,2 – 12,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci drugiego stopnia (pozostałej w próbce)\nZakres (0,2 – 12,0) %\nMetoda wagowa","reference":"PN-ISO 589:2006, metoda A1","norm_bases":["PN-ISO 589:2006, metoda A1"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe – węgiel kamienny Zawartość wilgoci drugiego stopnia (pozostałej w próbce)\nZakres (0,2 – 12,0) %\nMetoda wagowa PN-ISO 589:2006, metoda A1 Paliwa stale – wegiel kamienny Zawartosc wilgoci drugiego stopnia (pozostalej w probce)\nZakres (0,2 – 12,0) %\nMetoda wagowa PN-ISO 589:2006, metoda A1","categories":["petro"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","parameters_en":[{"name":"Range","range":"(0,2 – 12,0) %"}],"search_en":"Solid fuels – hard coal Gravimetric method Environmental Protection Laboratory Range PN-ISO 589:2006, metoda A1","technique_en":"Gravimetric method","test_object_en":"Solid fuels – hard coal","parameters_zh":[{"name":"范围","range":"(0,2 – 12,0) %"}],"search_zh":"固体燃料 — 烟煤 重量法 环境保护实验室 范围 PN-ISO 589:2006, metoda A1","technique_zh":"重量法","test_object_zh":"固体燃料 — 烟煤","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4ac","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Paliwa stałe – węgiel kamienny","methodology":"Zawartość wilgoci całkowitej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wilgoci całkowitej (z obliczeń)","reference":"PN-ISO 589:2006, metoda A1","norm_bases":["PN-ISO 589:2006, metoda A1"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe – węgiel kamienny Zawartość wilgoci całkowitej (z obliczeń) PN-ISO 589:2006, metoda A1 Paliwa stale – wegiel kamienny Zawartosc wilgoci calkowitej (z obliczen) PN-ISO 589:2006, metoda A1","categories":["petro"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Total moisture content (calculated)","search_en":"Solid fuels – hard coal Total moisture content (calculated) Environmental Protection Laboratory PN-ISO 589:2006, metoda A1","test_object_en":"Solid fuels – hard coal","search_zh":"固体燃料 — 烟煤 全水分含量（计算值） 环境保护实验室 PN-ISO 589:2006, metoda A1","test_object_zh":"固体燃料 — 烟煤","methodology_zh":"全水分含量（计算值）","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4ad","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Paliwa stałe – węgiel kamienny","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,2 – 12,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,2 – 12,0) %\nMetoda wagowa","reference":"PN-ISO 11722:2009","norm_bases":["PN-ISO 11722:2009"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe – węgiel kamienny Zawartość wilgoci w próbce analitycznej\nZakres (0,2 – 12,0) %\nMetoda wagowa PN-ISO 11722:2009 Paliwa stale – wegiel kamienny Zawartosc wilgoci w probce analitycznej\nZakres (0,2 – 12,0) %\nMetoda wagowa PN-ISO 11722:2009","categories":["petro"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,2 – 12,0) %"}],"search_en":"Solid fuels – hard coal Moisture content in the analytical sample Gravimetric method Environmental Protection Laboratory Range PN-ISO 11722:2009","technique_en":"Gravimetric method","test_object_en":"Solid fuels – hard coal","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,2 – 12,0) %"}],"search_zh":"固体燃料 — 烟煤 分析样品水分含量 重量法 环境保护实验室 范围 PN-ISO 11722:2009","technique_zh":"重量法","test_object_zh":"固体燃料 — 烟煤","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4ae","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Paliwa stałe – węgiel kamienny","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(14000 – 35000) kJ/kg"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres (14000 – 35000) kJ/kg\nMetoda kalorymetryczna","reference":"PN-ISO 1928:2020-05","norm_bases":["PN-ISO 1928:2020-05"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe – węgiel kamienny Ciepło spalania\nZakres (14000 – 35000) kJ/kg\nMetoda kalorymetryczna PN-ISO 1928:2020-05 Paliwa stale – wegiel kamienny Cieplo spalania\nZakres (14000 – 35000) kJ/kg\nMetoda kalorymetryczna PN-ISO 1928:2020-05","categories":["petro"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(14000 – 35000) kJ/kg"}],"search_en":"Solid fuels – hard coal Gross calorific value Calorimetric method Environmental Protection Laboratory Range PN-ISO 1928:2020-05","technique_en":"Calorimetric method","test_object_en":"Solid fuels – hard coal","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(14000 – 35000) kJ/kg"}],"search_zh":"固体燃料 — 烟煤 高位发热量 量热法 环境保护实验室 范围 PN-ISO 1928:2020-05","technique_zh":"量热法","test_object_zh":"固体燃料 — 烟煤","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4af","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Paliwa stałe – węgiel kamienny","methodology":"Wartość opałowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość opałowa (z obliczeń)","reference":"PN-ISO 1928:2020-05","norm_bases":["PN-ISO 1928:2020-05"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe – węgiel kamienny Wartość opałowa (z obliczeń) PN-ISO 1928:2020-05 Paliwa stale – wegiel kamienny Wartosc opalowa (z obliczen) PN-ISO 1928:2020-05","categories":["petro"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Net calorific value (calculated)","search_en":"Solid fuels – hard coal Net calorific value (calculated) Environmental Protection Laboratory PN-ISO 1928:2020-05","test_object_en":"Solid fuels – hard coal","methodology_zh":"低位发热量（计算值）","search_zh":"固体燃料 — 烟煤 低位发热量（计算值） 环境保护实验室 PN-ISO 1928:2020-05","test_object_zh":"固体燃料 — 烟煤","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4b0","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Odpady O): kod 10 01 01, 10 01 02, 10 01 80; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość wilgoci przemijającej","parameters":[{"name":"Zakres","range":"(0,1 – 50,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci przemijającej\nZakres (0,1 – 50,0) %\nMetoda wagowa","reference":"PN-G-04611:2020-06","norm_bases":["PN-G-04611:2020-06"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady O): kod 10 01 01, 10 01 02, 10 01 80; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość wilgoci przemijającej\nZakres (0,1 – 50,0) %\nMetoda wagowa PN-G-04611:2020-06 Odpady O): kod 10 01 01, 10 01 02, 10 01 80; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc wilgoci przemijajacej\nZakres (0,1 – 50,0) %\nMetoda wagowa PN-G-04611:2020-06","categories":["environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Free moisture content","parameters_en":[{"name":"Range","range":"(0,1 – 50,0) %"}],"search_en":"Free moisture content Gravimetric method Environmental Protection Laboratory Range PN-G-04611:2020-06","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(0,1 – 50,0) %"}],"search_zh":"外在水分含量 重量法 环境保护实验室 范围 PN-G-04611:2020-06","technique_zh":"重量法","lab_section_zh":"环境保护实验室","methodology_zh":"外在水分含量"},{"_id":"6a7f14241995264369d8e4b1","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Odpady O): kod 10 01 01, 10 01 02, 10 01 80; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,1 – 10,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,1 – 10,0) %\nMetoda wagowa","reference":"PN-G-04611:2020-06","norm_bases":["PN-G-04611:2020-06"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady O): kod 10 01 01, 10 01 02, 10 01 80; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość wilgoci w próbce analitycznej\nZakres (0,1 – 10,0) %\nMetoda wagowa PN-G-04611:2020-06 Odpady O): kod 10 01 01, 10 01 02, 10 01 80; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc wilgoci w probce analitycznej\nZakres (0,1 – 10,0) %\nMetoda wagowa PN-G-04611:2020-06","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,1 – 10,0) %"}],"search_en":"Moisture content in the analytical sample Gravimetric method Environmental Protection Laboratory Range PN-G-04611:2020-06","technique_en":"Gravimetric method","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,1 – 10,0) %"}],"search_zh":"分析样品水分含量 重量法 环境保护实验室 范围 PN-G-04611:2020-06","technique_zh":"重量法","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4b2","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Odpady O): kod 10 01 01, 10 01 02, 10 01 80; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość wilgoci całkowitej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wilgoci całkowitej (z obliczeń)","reference":"PN-G-04611:2020-06","norm_bases":["PN-G-04611:2020-06"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady O): kod 10 01 01, 10 01 02, 10 01 80; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość wilgoci całkowitej (z obliczeń) PN-G-04611:2020-06 Odpady O): kod 10 01 01, 10 01 02, 10 01 80; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc wilgoci calkowitej (z obliczen) PN-G-04611:2020-06","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Total moisture content (calculated)","search_en":"Total moisture content (calculated) Environmental Protection Laboratory PN-G-04611:2020-06","methodology_zh":"全水分含量（计算值）","search_zh":"全水分含量（计算值） 环境保护实验室 PN-G-04611:2020-06","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4b3","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Odpady O): kod 10 01 82; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,5 – 3,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,5 – 3,0) %\nMetoda wagowa","reference":"PN-G-04611:2020-06","norm_bases":["PN-G-04611:2020-06"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady O): kod 10 01 82; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość wilgoci w próbce analitycznej\nZakres (0,5 – 3,0) %\nMetoda wagowa PN-G-04611:2020-06 Odpady O): kod 10 01 82; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc wilgoci w probce analitycznej\nZakres (0,5 – 3,0) %\nMetoda wagowa PN-G-04611:2020-06","categories":["environment"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,5 – 3,0) %"}],"search_en":"Moisture content in the analytical sample Gravimetric method Environmental Protection Laboratory Range PN-G-04611:2020-06","technique_en":"Gravimetric method","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,5 – 3,0) %"}],"search_zh":"分析样品水分含量 重量法 环境保护实验室 范围 PN-G-04611:2020-06","technique_zh":"重量法","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4b4","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Odpady O): kod 10 01 01, 10 01 02, 10 01 80; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(1,00 – 40,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres (1,00 – 40,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady O): kod 10 01 01, 10 01 02, 10 01 80; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość węgla całkowitego\nZakres (1,00 – 40,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Odpady O): kod 10 01 01, 10 01 02, 10 01 80; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc wegla calkowitego\nZakres (1,00 – 40,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(1,00 – 40,00) %"}],"search_en":"Total carbon content High-temperature combustion with IR detection Environmental Protection Laboratory Range PN-G-04571:1998","technique_en":"High-temperature combustion with IR detection","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(1,00 – 40,00) %"}],"search_zh":"总碳含量 高温燃烧红外检测法 环境保护实验室 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4b5","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Odpady O): kod 10 01 82; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(2,00 – 30,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres (2,00 – 30,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady O): kod 10 01 82; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość węgla całkowitego\nZakres (2,00 – 30,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Odpady O): kod 10 01 82; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc wegla calkowitego\nZakres (2,00 – 30,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["environment"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(2,00 – 30,00) %"}],"search_en":"Total carbon content High-temperature combustion with IR detection Environmental Protection Laboratory Range PN-G-04571:1998","technique_en":"High-temperature combustion with IR detection","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(2,00 – 30,00) %"}],"search_zh":"总碳含量 高温燃烧红外检测法 环境保护实验室 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4b6","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"substancje nieorganiczne, w tym"},{"name":"frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje nieorganiczne, w tym\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje nieorganiczne, w tym\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy – powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje nieorganiczne, w tym\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"inorganic substances, including"},{"name":"respirable fraction"}],"search_en":"Workplace environment – air Sampling for the assessment of occupational exposure to: Personal dosimetry method Environmental Protection Laboratory dust agents inhalable fraction respirable fraction inorganic substances, including respirable fraction PN-Z-04008-7:2002+Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment – air","methodology_zh":"职业接触评估采样，针对：","parameters_zh":[{"name":"粉尘因素"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"无机物质，包括"},{"name":"呼吸性组分"}],"search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 环境保护实验室 粉尘因素 可吸入组分 呼吸性组分 无机物质，包括 呼吸性组分 PN-Z-04008-7:2002+Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4b7","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy – powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment – air Exposure index (calculated) Environmental Protection Laboratory PN-Z-04008-7:2002+Az1:2004","test_object_en":"Workplace environment – air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） 环境保护实验室 PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4b8","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:","parameters":[{"name":"Pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,19 –23,0) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nPyły niesklasyfikowane ze względu na toksyczność\nWęgiel (kamienny, brunatny)\nZakres (0,19 –23,0) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nPyły niesklasyfikowane ze względu na toksyczność\nWęgiel (kamienny, brunatny)\nZakres (0,19 –23,0) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nWegiel (kamienny, brunatny)\nZakres (0,19 –23,0) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Concentration of harmful dust agents - inhalable fraction:","parameters_en":[{"name":"Dusts not classified according to toxicity"},{"name":"Coal (hard, brown)"},{"name":"Range","range":"(0,19 –23,0) mg/m3"}],"search_en":"Workplace environment – air Concentration of harmful dust agents - inhalable fraction: Gravimetric method Environmental Protection Laboratory Dusts not classified according to toxicity Coal (hard, brown) Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"未按毒性分类的粉尘"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,19 –23,0) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分： 重量法 环境保护实验室 未按毒性分类的粉尘 煤（烟煤、褐煤） 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分：","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4b9","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja respirabilna:","parameters":[{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,12 – 10,0) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja respirabilna:\nZakres:\nWęgiel (kamienny, brunatny)\nZakres (0,12 – 10,0) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja respirabilna:\nZakres:\nWęgiel (kamienny, brunatny)\nZakres (0,12 – 10,0) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja respirabilna:\nZakres:\nWegiel (kamienny, brunatny)\nZakres (0,12 – 10,0) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Concentration of harmful dust agents - respirable fraction:","parameters_en":[{"name":"Coal (hard, brown)"},{"name":"Range","range":"(0,12 – 10,0) mg/m3"}],"search_en":"Workplace environment – air Concentration of harmful dust agents - respirable fraction: Gravimetric method Environmental Protection Laboratory Coal (hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,12 – 10,0) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害健康的粉尘因子浓度 － 呼吸性粉尘： 重量法 环境保护实验室 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"环境保护实验室","methodology_zh":"有害健康的粉尘因子浓度 － 呼吸性粉尘："},{"_id":"6a7f14241995264369d8e4ba","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne we wnętrzach","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(5 – 5000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (5 – 5000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-E-04040-03:1983","norm_bases":["PN-E-04040-03:1983"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (5 – 5000) lx\nMetoda pomiarowa bezpośrednia PN-E-04040-03:1983 Srodowisko pracy – oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (5 – 5000) lx\nMetoda pomiarowa bezposrednia PN-E-04040-03:1983","categories":["environment"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(5 – 5000) lx"}],"search_en":"Workplace environment – indoor electric lighting Illuminance Direct measurement method Environmental Protection Laboratory Range PN-E-04040-03:1983","technique_en":"Direct measurement method","test_object_en":"Workplace environment – indoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(5 – 5000) lx"}],"search_zh":"工作场所环境 — 室内电气照明 照度 直接测量法 环境保护实验室 范围 PN-E-04040-03:1983","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 室内电气照明","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4bb","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne we wnętrzach","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-E-04040-03:1983","norm_bases":["PN-E-04040-03:1983"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) PN-E-04040-03:1983 Srodowisko pracy – oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) PN-E-04040-03:1983","categories":["environment"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment – indoor electric lighting Illuminance uniformity (calculated) Environmental Protection Laboratory PN-E-04040-03:1983","test_object_en":"Workplace environment – indoor electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 — 室内电气照明 照度均匀度（计算值） 环境保护实验室 PN-E-04040-03:1983","test_object_zh":"工作场所环境 — 室内电气照明","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4bc","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25,0 – 136,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres (25,0 – 136,0) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - p. 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - p. 10 i 11"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres (25,0 – 136,0) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - p. 10 i 11 Srodowisko pracy – halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres (25,0 – 136,0) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 - p. 10 i 11","categories":["environment"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(25,0 – 136,0) dB"}],"search_en":"Workplace environment – noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Environmental Protection Laboratory Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - p. 10 i 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(25,0 – 136,0) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 环境保护实验室 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - p. 10 i 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4bd","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Szczytowy poziom dźwięku C","parameters":[{"name":"Zakres","range":"(25,0 – 140,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Szczytowy poziom dźwięku C\nZakres (25,0 – 140,0) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - p. 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - p. 10 i 11"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Szczytowy poziom dźwięku C\nZakres (25,0 – 140,0) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - p. 10 i 11 Srodowisko pracy – halas Szczytowy poziom dzwieku C\nZakres (25,0 – 140,0) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 - p. 10 i 11","categories":["environment"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"C-weighted peak sound pressure level","parameters_en":[{"name":"Range","range":"(25,0 – 140,0) dB"}],"search_en":"Workplace environment – noise C-weighted peak sound pressure level Direct measurement method Environmental Protection Laboratory Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - p. 10 i 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – noise","methodology_zh":"C 计权峰值声级","parameters_zh":[{"name":"范围","range":"(25,0 – 140,0) dB"}],"search_zh":"工作场所环境 — 噪声 C 计权峰值声级 直接测量法 环境保护实验室 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - p. 10 i 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4be","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - p. 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - p. 10 i 11"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - p. 10 i 11 Srodowisko pracy – halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 - p. 10 i 11","categories":["environment"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment – noise Noise exposure level referred to: Environmental Protection Laboratory an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - p. 10 i 11","test_object_en":"Workplace environment – noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 环境保护实验室 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - p. 10 i 11","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4bf","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(24,0 – 130,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (24,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) | PN-ISO 9613-2:2002","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)","PN-ISO 9613-2:2002"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (24,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) | PN-ISO 9613-2:2002 Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (24,0 – 130,0) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) | PN-ISO 9613-2:2002","categories":["environment"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(24,0 – 130,0) dB"}],"search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Environmental Protection Laboratory Range Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) | PN-ISO 9613-2:2002","technique_en":"Direct measurement method","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(24,0 – 130,0) dB"}],"search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 A 计权等效声级 直接测量法 环境保护实验室 范围 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) | PN-ISO 9613-2:2002","technique_zh":"直接测量法","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4c0","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) | PN-ISO 9613-2:2002","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)","PN-ISO 9613-2:2002"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) | PN-ISO 9613-2:2002 Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) | PN-ISO 9613-2:2002","categories":["environment"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Environmental Protection Laboratory Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) | PN-ISO 9613-2:2002","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） 环境保护实验室 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) | PN-ISO 9613-2:2002","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4c1","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN","parameters":[],"technique":"Metoda obliczeniowa","techniques":["Metoda obliczeniowa"],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN\nMetoda obliczeniowa","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) | PN-ISO 9613-2:2002","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)","PN-ISO 9613-2:2002"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN\nMetoda obliczeniowa Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) | PN-ISO 9613-2:2002 Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN\nMetoda obliczeniowa Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) | PN-ISO 9613-2:2002","categories":["environment"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Equivalent A-weighted sound level for the reference time T expressed by the indicators LAeqD and LAeqN","search_en":"General environment – noise from installations, equipment and industrial plants Equivalent A-weighted sound level for the reference time T expressed by the indicators LAeqD and LAeqN Calculation method Environmental Protection Laboratory Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) | PN-ISO 9613-2:2002","technique_en":"Calculation method","test_object_en":"General environment – noise from installations, equipment and industrial plants","search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 以 LAeqD 与 LAeqN 指标表示的参考时段 T 内的 A 计权等效声级 计算法 环境保护实验室 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) | PN-ISO 9613-2:2002","technique_zh":"计算法","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声","lab_section_zh":"环境保护实验室","methodology_zh":"以 LAeqD 与 LAeqN 指标表示的参考时段 T 内的 A 计权等效声级"},{"_id":"6a7f14241995264369d8e4c2","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","methodology":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(24,0 – 130,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (24,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) NMPB-Routes-96 (XPS 31-133)","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) NMPB-Routes-96 (XPS 31-133)"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (24,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) NMPB-Routes-96 (XPS 31-133) Srodowisko ogolne – halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A Ekspozycyjny poziom dzwieku A\nZakres (24,0 – 130,0) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) NMPB-Routes-96 (XPS 31-133)","categories":["environment"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"A-weighted equivalent sound level A-weighted sound exposure level","parameters_en":[{"name":"Range","range":"(24,0 – 130,0) dB"}],"search_en":"General environment – noise from roads, railway lines, tram lines A-weighted equivalent sound level A-weighted sound exposure level Direct measurement method Environmental Protection Laboratory Range Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) NMPB-Routes-96 (XPS 31-133)","technique_en":"Direct measurement method","test_object_en":"General environment – noise from roads, railway lines, tram lines","parameters_zh":[{"name":"范围","range":"(24,0 – 130,0) dB"}],"search_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声 A 计权等效声级 A 计权声暴露级 直接测量法 环境保护实验室 范围 Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) NMPB-Routes-96 (XPS 31-133)","technique_zh":"直接测量法","test_object_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声","methodology_zh":"A 计权等效声级 A 计权声暴露级","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4c3","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) NMPB-Routes-96 (XPS 31-133)","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) NMPB-Routes-96 (XPS 31-133)"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) NMPB-Routes-96 (XPS 31-133) Srodowisko ogolne – halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) NMPB-Routes-96 (XPS 31-133)","categories":["environment"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment – noise from roads, railway lines, tram lines A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Environmental Protection Laboratory Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) NMPB-Routes-96 (XPS 31-133)","test_object_en":"General environment – noise from roads, railway lines, tram lines","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） 环境保护实验室 Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) NMPB-Routes-96 (XPS 31-133)","test_object_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4c4","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN","parameters":[],"technique":"Metoda obliczeniowa","techniques":["Metoda obliczeniowa"],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN\nMetoda obliczeniowa","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) NMPB-Routes-96 (XPS 31-133)","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) NMPB-Routes-96 (XPS 31-133)"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN\nMetoda obliczeniowa Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) NMPB-Routes-96 (XPS 31-133) Srodowisko ogolne – halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN\nMetoda obliczeniowa Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) NMPB-Routes-96 (XPS 31-133)","categories":["environment"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Equivalent A-weighted sound level for the reference time T expressed by the indicators LAeqD and LAeqN","search_en":"General environment – noise from roads, railway lines, tram lines Equivalent A-weighted sound level for the reference time T expressed by the indicators LAeqD and LAeqN Calculation method Environmental Protection Laboratory Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) NMPB-Routes-96 (XPS 31-133)","technique_en":"Calculation method","test_object_en":"General environment – noise from roads, railway lines, tram lines","search_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声 以 LAeqD 与 LAeqN 指标表示的参考时段 T 内的 A 计权等效声级 计算法 环境保护实验室 Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) NMPB-Routes-96 (XPS 31-133)","technique_zh":"计算法","test_object_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声","lab_section_zh":"环境保护实验室","methodology_zh":"以 LAeqD 与 LAeqN 指标表示的参考时段 T 内的 A 计权等效声级"},{"_id":"6a7f14241995264369d8e4c5","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(22,0 – 130,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres (22,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-87/B-02156","norm_bases":["PN-87/B-02156"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres (22,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia PN-87/B-02156 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres (22,0 – 130,0) dB\nMetoda pomiarowa bezposrednia PN-87/B-02156","categories":["environment"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(22,0 – 130,0) dB"}],"search_en":"Rooms in residential, collective residence and public utility buildings – noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Environmental Protection Laboratory Range PN-87/B-02156","technique_en":"Direct measurement method","test_object_en":"Rooms in residential, collective residence and public utility buildings – noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(22,0 – 130,0) dB"}],"search_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声 A 计权等效声级 A 计权最大声级 直接测量法 环境保护实验室 范围 PN-87/B-02156","technique_zh":"直接测量法","test_object_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4c6","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń)","reference":"PN-87/B-02156","norm_bases":["PN-87/B-02156"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń) PN-87/B-02156 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas Rownowazny poziom dzwieku A dla czasu odniesienia T (z obliczen) PN-87/B-02156","categories":["environment"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"A-weighted equivalent sound level for reference time T (calculated)","search_en":"Rooms in residential, collective residence and public utility buildings – noise A-weighted equivalent sound level for reference time T (calculated) Environmental Protection Laboratory PN-87/B-02156","test_object_en":"Rooms in residential, collective residence and public utility buildings – noise","methodology_zh":"参考时间 T 内的 A 计权等效声级（计算得出）","search_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声 参考时间 T 内的 A 计权等效声级（计算得出） 环境保护实验室 PN-87/B-02156","test_object_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4c7","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(22,0 – 130,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres (22,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 10052:2007+ A1:2010 | PN-EN ISO 10052:2021-12","norm_bases":["PN-EN ISO 10052:2007+ A1:2010","PN-EN ISO 10052:2021-12"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres (22,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia PN-EN ISO 10052:2007+ A1:2010 | PN-EN ISO 10052:2021-12 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres (22,0 – 130,0) dB\nMetoda pomiarowa bezposrednia PN-EN ISO 10052:2007+ A1:2010 | PN-EN ISO 10052:2021-12","categories":["environment"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(22,0 – 130,0) dB"}],"search_en":"Rooms in residential, collective residence and public utility buildings – noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Environmental Protection Laboratory Range PN-EN ISO 10052:2007+ A1:2010 | PN-EN ISO 10052:2021-12","technique_en":"Direct measurement method","test_object_en":"Rooms in residential, collective residence and public utility buildings – noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(22,0 – 130,0) dB"}],"search_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声 A 计权等效声级 A 计权最大声级 直接测量法 环境保护实验室 范围 PN-EN ISO 10052:2007+ A1:2010 | PN-EN ISO 10052:2021-12","technique_zh":"直接测量法","test_object_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4c8","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas","methodology":"Wzorcowy równoważny poziom dźwięku A, Wzorcowy maksymalny poziom dźwięku A (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wzorcowy równoważny poziom dźwięku A, Wzorcowy maksymalny poziom dźwięku A (z obliczeń)","reference":"PN-EN ISO 10052:2007+ A1:2010 | PN-EN ISO 10052:2021-12","norm_bases":["PN-EN ISO 10052:2007+ A1:2010","PN-EN ISO 10052:2021-12"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas Wzorcowy równoważny poziom dźwięku A, Wzorcowy maksymalny poziom dźwięku A (z obliczeń) PN-EN ISO 10052:2007+ A1:2010 | PN-EN ISO 10052:2021-12 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas Wzorcowy rownowazny poziom dzwieku A, Wzorcowy maksymalny poziom dzwieku A (z obliczen) PN-EN ISO 10052:2007+ A1:2010 | PN-EN ISO 10052:2021-12","categories":["environment","metrology"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","search_en":"Rooms in residential, collective residence and public utility buildings – noise Environmental Protection Laboratory PN-EN ISO 10052:2007+ A1:2010 | PN-EN ISO 10052:2021-12","test_object_en":"Rooms in residential, collective residence and public utility buildings – noise","search_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声 环境保护实验室 PN-EN ISO 10052:2007+ A1:2010 | PN-EN ISO 10052:2021-12","test_object_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4c9","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Maszyny i urządzenia – hałas","methodology":"Poziom ciśnienia akustycznego skorygowany charakterystyką częstotliwościową A","parameters":[{"name":"Zakres","range":"(24,0 – 137,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Poziom ciśnienia akustycznego skorygowany charakterystyką częstotliwościową A\nZakres (24,0 – 137,0) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 3746:2011+Ap1:2017-09","norm_bases":["PN-EN ISO 3746:2011+Ap1:2017-09"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia – hałas Poziom ciśnienia akustycznego skorygowany charakterystyką częstotliwościową A\nZakres (24,0 – 137,0) dB\nMetoda pomiarowa bezpośrednia PN-EN ISO 3746:2011+Ap1:2017-09 Maszyny i urzadzenia – halas Poziom cisnienia akustycznego skorygowany charakterystyka czestotliwosciowa A\nZakres (24,0 – 137,0) dB\nMetoda pomiarowa bezposrednia PN-EN ISO 3746:2011+Ap1:2017-09","categories":["environment"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"A-frequency-weighted sound pressure level","parameters_en":[{"name":"Range","range":"(24,0 – 137,0) dB"}],"search_en":"Machinery and equipment – noise A-frequency-weighted sound pressure level Direct measurement method Environmental Protection Laboratory Range PN-EN ISO 3746:2011+Ap1:2017-09","technique_en":"Direct measurement method","test_object_en":"Machinery and equipment – noise","parameters_zh":[{"name":"范围","range":"(24,0 – 137,0) dB"}],"search_zh":"机器与设备 – 噪声 直接测量法 环境保护实验室 范围 PN-EN ISO 3746:2011+Ap1:2017-09","technique_zh":"直接测量法","test_object_zh":"机器与设备 – 噪声","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4ca","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Maszyny i urządzenia – hałas","methodology":"Poziom mocy akustycznej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Poziom mocy akustycznej (z obliczeń)","reference":"PN-EN ISO 3746:2011+Ap1:2017-09","norm_bases":["PN-EN ISO 3746:2011+Ap1:2017-09"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia – hałas Poziom mocy akustycznej (z obliczeń) PN-EN ISO 3746:2011+Ap1:2017-09 Maszyny i urzadzenia – halas Poziom mocy akustycznej (z obliczen) PN-EN ISO 3746:2011+Ap1:2017-09","categories":["environment"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Sound power level (calculated)","search_en":"Machinery and equipment – noise Sound power level (calculated) Environmental Protection Laboratory PN-EN ISO 3746:2011+Ap1:2017-09","test_object_en":"Machinery and equipment – noise","search_zh":"机器与设备 – 噪声 声功率级（计算值） 环境保护实验室 PN-EN ISO 3746:2011+Ap1:2017-09","test_object_zh":"机器与设备 – 噪声","methodology_zh":"声功率级（计算值）","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4cb","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Środowisko ogólne - ekrany akustyczne „in situ”","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(24,0 – 130,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (24,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-ISO 10847:2002","norm_bases":["PN-ISO 10847:2002"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - ekrany akustyczne „in situ” Równoważny poziom dźwięku A\nZakres (24,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia PN-ISO 10847:2002 Srodowisko ogolne - ekrany akustyczne „in situ” Rownowazny poziom dzwieku A\nZakres (24,0 – 130,0) dB\nMetoda pomiarowa bezposrednia PN-ISO 10847:2002","categories":["environment"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(24,0 – 130,0) dB"}],"search_en":"General environment - noise barriers „in situ” A-weighted equivalent sound pressure level Direct measurement method Environmental Protection Laboratory Range PN-ISO 10847:2002","technique_en":"Direct measurement method","test_object_en":"General environment - noise barriers „in situ”","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(24,0 – 130,0) dB"}],"search_zh":"一般环境 － 声屏障「现场」 A 计权等效声级 直接测量法 环境保护实验室 范围 PN-ISO 10847:2002","technique_zh":"直接测量法","lab_section_zh":"环境保护实验室","test_object_zh":"一般环境 － 声屏障「现场」"},{"_id":"6a7f14241995264369d8e4cc","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Środowisko ogólne - ekrany akustyczne „in situ”","methodology":"Skuteczność ekranów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczność ekranów (z obliczeń)","reference":"PN-ISO 10847:2002","norm_bases":["PN-ISO 10847:2002"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - ekrany akustyczne „in situ” Skuteczność ekranów (z obliczeń) PN-ISO 10847:2002 Srodowisko ogolne - ekrany akustyczne „in situ” Skutecznosc ekranow (z obliczen) PN-ISO 10847:2002","categories":["environment"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Effectiveness of screens (calculated)","search_en":"General environment - noise barriers „in situ” Effectiveness of screens (calculated) Environmental Protection Laboratory PN-ISO 10847:2002","test_object_en":"General environment - noise barriers „in situ”","lab_section_zh":"环境保护实验室","search_zh":"一般环境 － 声屏障「现场」 屏蔽效能（由计算得出） 环境保护实验室 PN-ISO 10847:2002","methodology_zh":"屏蔽效能（由计算得出）","test_object_zh":"一般环境 － 声屏障「现场」"},{"_id":"6a7f14241995264369d8e4cd","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia frakcji pyłu PM 2,5 i PM 10","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia frakcji pyłu PM 2,5 i PM 10","reference":"PN-Z-04030-7:1994 I04/L05 wydanie 1 z dnia 12.03.2019 r.","norm_bases":["PN-Z-04030-7:1994 I04/L05 wydanie 1 z dnia 12.03.2019 r."],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia frakcji pyłu PM 2,5 i PM 10 PN-Z-04030-7:1994 I04/L05 wydanie 1 z dnia 12.03.2019 r. Gazy odlotowe Pobieranie probek do oznaczania stezenia frakcji pylu PM 2,5 i PM 10 PN-Z-04030-7:1994 I04/L05 wydanie 1 z dnia 12.03.2019 r.","categories":["other"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Sampling for determination of the concentration of dust fractions PM 2,5 and PM 10","search_en":"Waste gases Sampling for determination of the concentration of dust fractions PM 2,5 and PM 10 Environmental Protection Laboratory PN-Z-04030-7:1994 I04/L05 wydanie 1 z dnia 12.03.2019 r.","test_object_en":"Waste gases","search_zh":"废气 环境保护实验室 PN-Z-04030-7:1994 I04/L05 wydanie 1 z dnia 12.03.2019 r.","test_object_zh":"废气","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4ce","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja frakcji pyłu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja frakcji pyłu (z obliczeń)","reference":"PN-Z-04030-7:1994 I04/L05 wydanie 1 z dnia 12.03.2019 r.","norm_bases":["PN-Z-04030-7:1994 I04/L05 wydanie 1 z dnia 12.03.2019 r."],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja frakcji pyłu (z obliczeń) PN-Z-04030-7:1994 I04/L05 wydanie 1 z dnia 12.03.2019 r. Gazy odlotowe Emisja frakcji pylu (z obliczen) PN-Z-04030-7:1994 I04/L05 wydanie 1 z dnia 12.03.2019 r.","categories":["environment"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Emission of the dust fraction (calculated)","search_en":"Waste gases Emission of the dust fraction (calculated) Environmental Protection Laboratory PN-Z-04030-7:1994 I04/L05 wydanie 1 z dnia 12.03.2019 r.","test_object_en":"Waste gases","search_zh":"废气 粉尘分级排放（由计算得出） 环境保护实验室 PN-Z-04030-7:1994 I04/L05 wydanie 1 z dnia 12.03.2019 r.","test_object_zh":"废气","lab_section_zh":"环境保护实验室","methodology_zh":"粉尘分级排放（由计算得出）"},{"_id":"6a7f14241995264369d8e4cf","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia metali w pyle (Al, As, Ba, Cd, Cr, Co, Cu, Sn, Zn, Fe, Mn, Ni, Pb, Sb, Tl, V)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia metali w pyle (Al, As, Ba, Cd, Cr, Co, Cu, Sn, Zn, Fe, Mn, Ni, Pb, Sb, Tl, V)","reference":"PN-Z-04030-7:1994 I05/L05 wydanie 1 z dnia 12.03.2019 r.","norm_bases":["PN-Z-04030-7:1994 I05/L05 wydanie 1 z dnia 12.03.2019 r."],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia metali w pyle (Al, As, Ba, Cd, Cr, Co, Cu, Sn, Zn, Fe, Mn, Ni, Pb, Sb, Tl, V) PN-Z-04030-7:1994 I05/L05 wydanie 1 z dnia 12.03.2019 r. Gazy odlotowe Pobieranie probek do oznaczania stezenia metali w pyle (Al, As, Ba, Cd, Cr, Co, Cu, Sn, Zn, Fe, Mn, Ni, Pb, Sb, Tl, V) PN-Z-04030-7:1994 I05/L05 wydanie 1 z dnia 12.03.2019 r.","categories":["materials"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Sampling for determination of metal concentrations in dust (Al, As, Ba, Cd, Cr, Co, Cu, Sn, Zn, Fe, Mn, Ni, Pb, Sb, Tl, V)","search_en":"Waste gases Sampling for determination of metal concentrations in dust (Al, As, Ba, Cd, Cr, Co, Cu, Sn, Zn, Fe, Mn, Ni, Pb, Sb, Tl, V) Environmental Protection Laboratory PN-Z-04030-7:1994 I05/L05 wydanie 1 z dnia 12.03.2019 r.","test_object_en":"Waste gases","search_zh":"废气 环境保护实验室 PN-Z-04030-7:1994 I05/L05 wydanie 1 z dnia 12.03.2019 r.","test_object_zh":"废气","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4d0","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja metali w pyle (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja metali w pyle (z obliczeń)","reference":"PN-Z-04030-7:1994 I05/L05 wydanie 1 z dnia 12.03.2019 r.","norm_bases":["PN-Z-04030-7:1994 I05/L05 wydanie 1 z dnia 12.03.2019 r."],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja metali w pyle (z obliczeń) PN-Z-04030-7:1994 I05/L05 wydanie 1 z dnia 12.03.2019 r. Gazy odlotowe Emisja metali w pyle (z obliczen) PN-Z-04030-7:1994 I05/L05 wydanie 1 z dnia 12.03.2019 r.","categories":["materials","environment"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Emission of metals in dust (calculated)","search_en":"Waste gases Emission of metals in dust (calculated) Environmental Protection Laboratory PN-Z-04030-7:1994 I05/L05 wydanie 1 z dnia 12.03.2019 r.","test_object_en":"Waste gases","search_zh":"废气 粉尘中的金属排放（由计算得出） 环境保护实验室 PN-Z-04030-7:1994 I05/L05 wydanie 1 z dnia 12.03.2019 r.","test_object_zh":"废气","lab_section_zh":"环境保护实验室","methodology_zh":"粉尘中的金属排放（由计算得出）"},{"_id":"6a7f14241995264369d8e4d1","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia amoniaku (NH3)","parameters":[],"technique":"Metoda aspiracyjna","techniques":["Metoda aspiracyjna"],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia amoniaku (NH3)\nMetoda aspiracyjna","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia amoniaku (NH3)\nMetoda aspiracyjna PN-EN ISO 21877:2020-03 Gazy odlotowe Pobieranie probek do oznaczania stezenia amoniaku (NH3)\nMetoda aspiracyjna PN-EN ISO 21877:2020-03","categories":["other"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Sampling for the determination of ammonia (NH3) concentration","search_en":"Waste gases Sampling for the determination of ammonia (NH3) concentration Aspiration method Environmental Protection Laboratory PN-EN ISO 21877:2020-03","technique_en":"Aspiration method","test_object_en":"Waste gases","search_zh":"废气 抽气法 环境保护实验室 PN-EN ISO 21877:2020-03","test_object_zh":"废气","technique_zh":"抽气法","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4d2","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja amoniaku (NH3) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja amoniaku (NH3) (z obliczeń)","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja amoniaku (NH3) (z obliczeń) PN-EN ISO 21877:2020-03 Gazy odlotowe Emisja amoniaku (NH3) (z obliczen) PN-EN ISO 21877:2020-03","categories":["environment"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Ammonia (NH3) emission (calculated)","search_en":"Waste gases Ammonia (NH3) emission (calculated) Environmental Protection Laboratory PN-EN ISO 21877:2020-03","test_object_en":"Waste gases","search_zh":"废气 氨（NH3）排放（由计算得出） 环境保护实验室 PN-EN ISO 21877:2020-03","test_object_zh":"废气","lab_section_zh":"环境保护实验室","methodology_zh":"氨（NH3）排放（由计算得出）"},{"_id":"6a7f14241995264369d8e4d3","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Urządzenia odpylające gazy odlotowe","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"(0,001 – 100) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna","reference":"PN-Z-04030-7:1994 | PN-M-34129:1987 metoda A","norm_bases":["PN-Z-04030-7:1994","PN-M-34129:1987 metoda A"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia odpylające gazy odlotowe Stężenie pyłu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 | PN-M-34129:1987 metoda A Urzadzenia odpylajace gazy odlotowe Stezenie pylu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 | PN-M-34129:1987 metoda A","categories":["other"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"(0,001 – 100) g/m3"}],"search_en":"Waste gas dedusting equipment Dust concentration Gravimetric method Environmental Protection Laboratory Range PN-Z-04030-7:1994 | PN-M-34129:1987 metoda A","technique_en":"Gravimetric method","test_object_en":"Waste gas dedusting equipment","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,001 – 100) g/m3"}],"search_zh":"废气除尘设备 粉尘浓度 重量法 环境保护实验室 范围 PN-Z-04030-7:1994 | PN-M-34129:1987 metoda A","technique_zh":"重量法","test_object_zh":"废气除尘设备","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4d4","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Urządzenia odpylające gazy odlotowe","methodology":"Skuteczność odpylania (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczność odpylania (z obliczeń)","reference":"PN-Z-04030-7:1994 | PN-M-34129:1987 metoda A","norm_bases":["PN-Z-04030-7:1994","PN-M-34129:1987 metoda A"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia odpylające gazy odlotowe Skuteczność odpylania (z obliczeń) PN-Z-04030-7:1994 | PN-M-34129:1987 metoda A Urzadzenia odpylajace gazy odlotowe Skutecznosc odpylania (z obliczen) PN-Z-04030-7:1994 | PN-M-34129:1987 metoda A","categories":["other"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Dust removal efficiency (calculated)","search_en":"Waste gas dedusting equipment Dust removal efficiency (calculated) Environmental Protection Laboratory PN-Z-04030-7:1994 | PN-M-34129:1987 metoda A","test_object_en":"Waste gas dedusting equipment","search_zh":"废气除尘设备 除尘效率（由计算得出） 环境保护实验室 PN-Z-04030-7:1994 | PN-M-34129:1987 metoda A","test_object_zh":"废气除尘设备","lab_section_zh":"环境保护实验室","methodology_zh":"除尘效率（由计算得出）"},{"_id":"6a7f14241995264369d8e4d5","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa","parameters":[],"technique":"Metoda spiętrzenia","techniques":["Metoda spiętrzenia"],"computed":[],"activity":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa\nMetoda spiętrzenia","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo Ochrony Środowiska","flexible":false,"search_text":"Gazy odlotowe Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa\nMetoda spiętrzenia PN-Z-04030-7:1994 Gazy odlotowe Strumien objetosci gazu dla cisnien dynamicznych > 10 Pa\nMetoda spietrzenia PN-Z-04030-7:1994","categories":["other"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Gas volume flow rate for dynamic pressures > 10 Pa","search_en":"Waste gases Gas volume flow rate for dynamic pressures > 10 Pa Stagnation pressure method Environmental Protection Laboratory PN-Z-04030-7:1994","technique_en":"Stagnation pressure method","test_object_en":"Waste gases","search_zh":"废气 动压 > 10 Pa 时的气体体积流量 滞止压力法 环境保护实验室 PN-Z-04030-7:1994","test_object_zh":"废气","lab_section_zh":"环境保护实验室","methodology_zh":"动压 > 10 Pa 时的气体体积流量","technique_zh":"滞止压力法"},{"_id":"6a7f14241995264369d8e4d6","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Prędkość","parameters":[{"name":"Zakres","range":"(0,2 – 40) m/s"}],"technique":"Metoda termoanemometryczna","techniques":["Metoda termoanemometryczna"],"computed":[],"activity":"Prędkość\nZakres (0,2 – 40) m/s\nMetoda termoanemometryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo Ochrony Środowiska","flexible":false,"search_text":"Gazy odlotowe Prędkość\nZakres (0,2 – 40) m/s\nMetoda termoanemometryczna PN-Z-04030-7:1994 Gazy odlotowe Predkosc\nZakres (0,2 – 40) m/s\nMetoda termoanemometryczna PN-Z-04030-7:1994","categories":["other"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Velocity","parameters_en":[{"name":"Range","range":"(0,2 – 40) m/s"}],"search_en":"Waste gases Velocity Thermoanemometric method Environmental Protection Laboratory Range PN-Z-04030-7:1994","technique_en":"Thermoanemometric method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,2 – 40) m/s"}],"search_zh":"废气 速度 热线风速仪法 环境保护实验室 范围 PN-Z-04030-7:1994","test_object_zh":"废气","lab_section_zh":"环境保护实验室","methodology_zh":"速度","technique_zh":"热线风速仪法"},{"_id":"6a7f14241995264369d8e4d7","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo Ochrony Środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-Z-04030-7:1994 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-Z-04030-7:1994","categories":["other"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Sampling for determination of dust concentration","search_en":"Waste gases Sampling for determination of dust concentration Environmental Protection Laboratory PN-Z-04030-7:1994","test_object_en":"Waste gases","search_zh":"废气 粉尘浓度测定采样 环境保护实验室 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4d8","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"(0,001 – 100) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo Ochrony Środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 Gazy odlotowe Stezenie pylu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994","categories":["other"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"(0,001 – 100) g/m3"}],"search_en":"Waste gases Dust concentration Gravimetric method Environmental Protection Laboratory Range PN-Z-04030-7:1994","technique_en":"Gravimetric method","test_object_en":"Waste gases","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,001 – 100) g/m3"}],"search_zh":"废气 粉尘浓度 重量法 环境保护实验室 范围 PN-Z-04030-7:1994","technique_zh":"重量法","test_object_zh":"废气","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4d9","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja pyłu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo Ochrony Środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-Z-04030-7:1994 Gazy odlotowe Emisja pylu (z obliczen) PN-Z-04030-7:1994","categories":["environment"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Dust emission (calculated)","search_en":"Waste gases Dust emission (calculated) Environmental Protection Laboratory PN-Z-04030-7:1994","test_object_en":"Waste gases","search_zh":"废气 粉尘排放量（计算值） 环境保护实验室 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4da","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie dwutlenku siarki, tlenku węgla, dwutlenku węgla, tlenu","parameters":[{"name":"SO2","range":"(10 – 3480) mg/m3"},{"name":"CO","range":"(4,0 – 6740) mg/m3"},{"name":"CO2","range":"(0,15 – 16,70) %"},{"name":"Zakres","range":"(1,0 - 21,0) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR); Metoda paramagnetyczna","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","Metoda paramagnetyczna"],"computed":[],"activity":"Stężenie dwutlenku siarki, tlenku węgla, dwutlenku węgla, tlenu\nZakres:\nSO2 (10 – 3480) mg/m3\nCO (4,0 – 6740) mg/m3\nCO2 (0,15 – 16,70) %\nZakres (1,0 - 21,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR); Metoda paramagnetyczna","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo Ochrony Środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie dwutlenku siarki, tlenku węgla, dwutlenku węgla, tlenu\nZakres:\nSO2 (10 – 3480) mg/m3\nCO (4,0 – 6740) mg/m3\nCO2 (0,15 – 16,70) %\nZakres (1,0 - 21,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR); Metoda paramagnetyczna PN-ISO 10396:2001 Gazy odlotowe Stezenie dwutlenku siarki, tlenku wegla, dwutlenku wegla, tlenu\nZakres:\nSO2 (10 – 3480) mg/m3\nCO (4,0 – 6740) mg/m3\nCO2 (0,15 – 16,70) %\nZakres (1,0 - 21,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR); Metoda paramagnetyczna PN-ISO 10396:2001","categories":["other"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","parameters_en":[{"name":"SO2","range":"(10 – 3480) mg/m3"},{"name":"CO","range":"(4,0 – 6740) mg/m3"},{"name":"CO2","range":"(0,15 – 16,70) %"},{"name":"Range","range":"(1,0 - 21,0) %"}],"search_en":"Waste gases Environmental Protection Laboratory SO2 CO CO2 Range PN-ISO 10396:2001","test_object_en":"Waste gases","parameters_zh":[{"name":"SO2","range":"(10 – 3480) mg/m3"},{"name":"CO","range":"(4,0 – 6740) mg/m3"},{"name":"CO2","range":"(0,15 – 16,70) %"},{"name":"范围","range":"(1,0 - 21,0) %"}],"search_zh":"废气 环境保护实验室 SO2 CO CO2 范围 PN-ISO 10396:2001","test_object_zh":"废气","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4db","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja SO2, CO, CO2 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja SO2, CO, CO2 (z obliczeń)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo Ochrony Środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja SO2, CO, CO2 (z obliczeń) PN-ISO 10396:2001 Gazy odlotowe Emisja SO2, CO, CO2 (z obliczen) PN-ISO 10396:2001","categories":["environment"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"SO2, CO, CO2 emission (calculated)","search_en":"Waste gases SO2, CO, CO2 emission (calculated) Environmental Protection Laboratory PN-ISO 10396:2001","test_object_en":"Waste gases","search_zh":"废气 环境保护实验室 PN-ISO 10396:2001","test_object_zh":"废气","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4dc","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenków azotu","parameters":[{"name":"NO","range":"(4,0 – 630) mg/m3"},{"name":"NOx","range":"(6,2 – 960) mg/m3"}],"technique":"Metoda chemiluminescencyjna","techniques":["Metoda chemiluminescencyjna"],"computed":[],"activity":"Stężenie tlenków azotu\nZakres:\nNO (4,0 – 630) mg/m3\nNOx (6,2 – 960) mg/m3\nMetoda chemiluminescencyjna","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo Ochrony Środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie tlenków azotu\nZakres:\nNO (4,0 – 630) mg/m3\nNOx (6,2 – 960) mg/m3\nMetoda chemiluminescencyjna PN-ISO 10396:2001 Gazy odlotowe Stezenie tlenkow azotu\nZakres:\nNO (4,0 – 630) mg/m3\nNOx (6,2 – 960) mg/m3\nMetoda chemiluminescencyjna PN-ISO 10396:2001","categories":["other"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Nitrogen oxides concentration","parameters_en":[{"name":"NO","range":"(4,0 – 630) mg/m3"},{"name":"NOx","range":"(6,2 – 960) mg/m3"}],"search_en":"Waste gases Nitrogen oxides concentration Chemiluminescence method Environmental Protection Laboratory NO NOx PN-ISO 10396:2001","technique_en":"Chemiluminescence method","test_object_en":"Waste gases","search_zh":"废气 氮氧化物浓度 化学发光法 环境保护实验室 NO NOx PN-ISO 10396:2001","test_object_zh":"废气","parameters_zh":[{"name":"NO","range":"(4,0 – 630) mg/m3"},{"name":"NOx","range":"(6,2 – 960) mg/m3"}],"technique_zh":"化学发光法","lab_section_zh":"环境保护实验室","methodology_zh":"氮氧化物浓度"},{"_id":"6a7f14241995264369d8e4dd","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja NO i NOx (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja NO i NOx (z obliczeń)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo Ochrony Środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja NO i NOx (z obliczeń) PN-ISO 10396:2001 Gazy odlotowe Emisja NO i NOx (z obliczen) PN-ISO 10396:2001","categories":["environment"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Emission of NO and NOx (calculated)","search_en":"Waste gases Emission of NO and NOx (calculated) Environmental Protection Laboratory PN-ISO 10396:2001","test_object_en":"Waste gases","search_zh":"废气 环境保护实验室 PN-ISO 10396:2001","test_object_zh":"废气","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4de","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenków azotu","parameters":[{"name":"NO","range":"(4,0 – 630) mg/m3"},{"name":"NOx","range":"(6,2 – 960) mg/m3"}],"technique":"Metoda chemiluminescencyjna","techniques":["Metoda chemiluminescencyjna"],"computed":[],"activity":"Stężenie tlenków azotu\nZakres:\nNO (4,0 – 630) mg/m3\nNOx (6,2 – 960) mg/m3\nMetoda chemiluminescencyjna","reference":"PN-EN 14792:2006","norm_bases":["PN-EN 14792:2006"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo Ochrony Środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie tlenków azotu\nZakres:\nNO (4,0 – 630) mg/m3\nNOx (6,2 – 960) mg/m3\nMetoda chemiluminescencyjna PN-EN 14792:2006 Gazy odlotowe Stezenie tlenkow azotu\nZakres:\nNO (4,0 – 630) mg/m3\nNOx (6,2 – 960) mg/m3\nMetoda chemiluminescencyjna PN-EN 14792:2006","categories":["other"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Nitrogen oxides concentration","parameters_en":[{"name":"NO","range":"(4,0 – 630) mg/m3"},{"name":"NOx","range":"(6,2 – 960) mg/m3"}],"search_en":"Waste gases Nitrogen oxides concentration Chemiluminescence method Environmental Protection Laboratory NO NOx PN-EN 14792:2006","technique_en":"Chemiluminescence method","test_object_en":"Waste gases","search_zh":"废气 氮氧化物浓度 化学发光法 环境保护实验室 NO NOx PN-EN 14792:2006","test_object_zh":"废气","parameters_zh":[{"name":"NO","range":"(4,0 – 630) mg/m3"},{"name":"NOx","range":"(6,2 – 960) mg/m3"}],"technique_zh":"化学发光法","lab_section_zh":"环境保护实验室","methodology_zh":"氮氧化物浓度"},{"_id":"6a7f14241995264369d8e4df","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja NO i NOx (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja NO i NOx (z obliczeń)","reference":"PN-EN 14792:2006","norm_bases":["PN-EN 14792:2006"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo Ochrony Środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja NO i NOx (z obliczeń) PN-EN 14792:2006 Gazy odlotowe Emisja NO i NOx (z obliczen) PN-EN 14792:2006","categories":["environment"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Emission of NO and NOx (calculated)","search_en":"Waste gases Emission of NO and NOx (calculated) Environmental Protection Laboratory PN-EN 14792:2006","test_object_en":"Waste gases","search_zh":"废气 环境保护实验室 PN-EN 14792:2006","test_object_zh":"废气","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4e0","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia chlorowodoru","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia chlorowodoru","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo Ochrony Środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia chlorowodoru PN-EN 1911:2011 Gazy odlotowe Pobieranie probek do oznaczania stezenia chlorowodoru PN-EN 1911:2011","categories":["other"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Sampling for determination of hydrogen chloride concentration","search_en":"Waste gases Sampling for determination of hydrogen chloride concentration Environmental Protection Laboratory PN-EN 1911:2011","test_object_en":"Waste gases","search_zh":"废气 氯化氢浓度测定采样 环境保护实验室 PN-EN 1911:2011","test_object_zh":"废气","lab_section_zh":"环境保护实验室","methodology_zh":"氯化氢浓度测定采样"},{"_id":"6a7f14241995264369d8e4e1","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja HCl (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja HCl (z obliczeń)","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo Ochrony Środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja HCl (z obliczeń) PN-EN 1911:2011 Gazy odlotowe Emisja HCl (z obliczen) PN-EN 1911:2011","categories":["environment"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"HCl emission (calculated)","search_en":"Waste gases HCl emission (calculated) Environmental Protection Laboratory PN-EN 1911:2011","test_object_en":"Waste gases","search_zh":"废气 HCl 排放（由计算得出） 环境保护实验室 PN-EN 1911:2011","test_object_zh":"废气","lab_section_zh":"环境保护实验室","methodology_zh":"HCl 排放（由计算得出）"},{"_id":"6a7f14241995264369d8e4e2","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia fluorowodoru","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia fluorowodoru","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo Ochrony Środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia fluorowodoru ISO 15713:2006 Gazy odlotowe Pobieranie probek do oznaczania stezenia fluorowodoru ISO 15713:2006","categories":["other"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Sampling for determination of hydrogen fluoride concentration","search_en":"Waste gases Sampling for determination of hydrogen fluoride concentration Environmental Protection Laboratory ISO 15713:2006","test_object_en":"Waste gases","search_zh":"废气 氟化氢浓度测定采样 环境保护实验室 ISO 15713:2006","test_object_zh":"废气","lab_section_zh":"环境保护实验室","methodology_zh":"氟化氢浓度测定采样"},{"_id":"6a7f14241995264369d8e4e3","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja HF (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja HF (z obliczeń)","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo Ochrony Środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja HF (z obliczeń) ISO 15713:2006 Gazy odlotowe Emisja HF (z obliczen) ISO 15713:2006","categories":["environment"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"HF emission (calculated)","search_en":"Waste gases HF emission (calculated) Environmental Protection Laboratory ISO 15713:2006","test_object_en":"Waste gases","search_zh":"废气 HF 排放量（计算值） 环境保护实验室 ISO 15713:2006","test_object_zh":"废气","lab_section_zh":"环境保护实验室","methodology_zh":"HF 排放量（计算值）"},{"_id":"6a7f14241995264369d8e4e4","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych PN-EN 13649:2005 Gazy odlotowe Pobieranie probek do oznaczania stezenia indywidualnych gazowych zwiazkow organicznych PN-EN 13649:2005","categories":["other"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Sampling for determination of the concentration of individual gaseous organic compounds","regulatory_area_en":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for determination of the concentration of individual gaseous organic compounds Environmental Protection Laboratory Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 13649:2005","test_object_en":"Waste gases","search_zh":"废气 单项气态有机化合物浓度测定采样 环境保护实验室 Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 13649:2005","test_object_zh":"废气","regulatory_area_zh":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","lab_section_zh":"环境保护实验室","methodology_zh":"单项气态有机化合物浓度测定采样"},{"_id":"6a7f14241995264369d8e4e5","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja indywidualnych gazowych związków organicznych (z obliczeń) PN-EN 13649:2005 Gazy odlotowe Emisja indywidualnych gazowych zwiazkow organicznych (z obliczen) PN-EN 13649:2005","categories":["environment"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Emission of individual gaseous organic compounds (calculated)","regulatory_area_en":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Emission of individual gaseous organic compounds (calculated) Environmental Protection Laboratory Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 13649:2005","test_object_en":"Waste gases","search_zh":"废气 单项气态有机化合物排放量（计算值） 环境保护实验室 Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 13649:2005","test_object_zh":"废气","methodology_zh":"单项气态有机化合物排放量（计算值）","regulatory_area_zh":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4e6","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężeń związków organicznych","parameters":[],"technique":"Metoda aspiracyjna z zastosowaniem roztworów pochłaniających i adsorbentów","techniques":["Metoda aspiracyjna z zastosowaniem roztworów pochłaniających i adsorbentów"],"computed":[],"activity":"Pobieranie próbek do oznaczania stężeń związków organicznych\nMetoda aspiracyjna z zastosowaniem roztworów pochłaniających i adsorbentów","reference":"PN-Z-04008-4:1999","norm_bases":["PN-Z-04008-4:1999"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężeń związków organicznych\nMetoda aspiracyjna z zastosowaniem roztworów pochłaniających i adsorbentów PN-Z-04008-4:1999 Gazy odlotowe Pobieranie probek do oznaczania stezen zwiazkow organicznych\nMetoda aspiracyjna z zastosowaniem roztworow pochlaniajacych i adsorbentow PN-Z-04008-4:1999","categories":["other"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Sampling for determination of concentrations of organic compounds","regulatory_area_en":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for determination of concentrations of organic compounds Environmental Protection Laboratory Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-Z-04008-4:1999","test_object_en":"Waste gases","search_zh":"废气 有机化合物浓度测定采样 环境保护实验室 Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-Z-04008-4:1999","test_object_zh":"废气","regulatory_area_zh":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","lab_section_zh":"环境保护实验室","methodology_zh":"有机化合物浓度测定采样"},{"_id":"6a7f14241995264369d8e4e7","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja związków organicznych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja związków organicznych (z obliczeń)","reference":"PN-Z-04008-4:1999","norm_bases":["PN-Z-04008-4:1999"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja związków organicznych (z obliczeń) PN-Z-04008-4:1999 Gazy odlotowe Emisja zwiazkow organicznych (z obliczen) PN-Z-04008-4:1999","categories":["environment"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Emission of organic compounds (calculated)","regulatory_area_en":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Emission of organic compounds (calculated) Environmental Protection Laboratory Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-Z-04008-4:1999","test_object_en":"Waste gases","search_zh":"废气 有机化合物排放量（计算值） 环境保护实验室 Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-Z-04008-4:1999","test_object_zh":"废气","methodology_zh":"有机化合物排放量（计算值）","regulatory_area_zh":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4e8","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V","reference":"PN-EN 14385:2025","norm_bases":["PN-EN 14385:2025"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V PN-EN 14385:2025 Gazy odlotowe Pobieranie probek do oznaczania stezenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V PN-EN 14385:2025","categories":["materials"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V","regulatory_area_en":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V Environmental Protection Laboratory Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 14385:2025","test_object_en":"Waste gases","search_zh":"废气 用于测定金属浓度的采样：As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V 环境保护实验室 Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 14385:2025","test_object_zh":"废气","regulatory_area_zh":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","lab_section_zh":"环境保护实验室","methodology_zh":"用于测定金属浓度的采样：As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V"},{"_id":"6a7f14241995264369d8e4e9","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń)","reference":"PN-EN 14385:2025","norm_bases":["PN-EN 14385:2025"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń) PN-EN 14385:2025 Gazy odlotowe Emisja metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczen) PN-EN 14385:2025","categories":["materials","environment"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Emission of metals: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated)","regulatory_area_en":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Emission of metals: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated) Environmental Protection Laboratory Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 14385:2025","test_object_en":"Waste gases","search_zh":"废气 金属排放：As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V（由计算得出） 环境保护实验室 Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 14385:2025","test_object_zh":"废气","regulatory_area_zh":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","lab_section_zh":"环境保护实验室","methodology_zh":"金属排放：As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V（由计算得出）"},{"_id":"6a7f14241995264369d8e4ea","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej","reference":"PN-EN 13211+AC:2006","norm_bases":["PN-EN 13211+AC:2006"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia rtęci ogólnej PN-EN 13211+AC:2006 Gazy odlotowe Pobieranie probek do oznaczania stezenia rteci ogolnej PN-EN 13211+AC:2006","categories":["other"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Sampling for determination of total mercury concentration","regulatory_area_en":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for determination of total mercury concentration Environmental Protection Laboratory Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 13211+AC:2006","test_object_en":"Waste gases","search_zh":"废气 总汞浓度测定采样 环境保护实验室 Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 13211+AC:2006","test_object_zh":"废气","regulatory_area_zh":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","lab_section_zh":"环境保护实验室","methodology_zh":"总汞浓度测定采样"},{"_id":"6a7f14241995264369d8e4eb","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja Hg (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja Hg (z obliczeń)","reference":"PN-EN 13211+AC:2006","norm_bases":["PN-EN 13211+AC:2006"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja Hg (z obliczeń) PN-EN 13211+AC:2006 Gazy odlotowe Emisja Hg (z obliczen) PN-EN 13211+AC:2006","categories":["environment"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Hg emission (calculated)","regulatory_area_en":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Hg emission (calculated) Environmental Protection Laboratory Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 13211+AC:2006","test_object_en":"Waste gases","search_zh":"废气 Hg 排放（由计算得出） 环境保护实验室 Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 13211+AC:2006","test_object_zh":"废气","regulatory_area_zh":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","lab_section_zh":"环境保护实验室","methodology_zh":"Hg 排放（由计算得出）"},{"_id":"6a7f14241995264369d8e4ec","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-EN ISO 13284-1:2018-02","norm_bases":["PN-EN ISO 13284-1:2018-02"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-EN ISO 13284-1:2018-02 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-EN ISO 13284-1:2018-02","categories":["other"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Sampling for determination of dust concentration","regulatory_area_en":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for determination of dust concentration Environmental Protection Laboratory Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN ISO 13284-1:2018-02","test_object_en":"Waste gases","search_zh":"废气 粉尘浓度测定采样 环境保护实验室 Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN ISO 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样","regulatory_area_zh":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4ed","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"(0,0005 – 0,05) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu\nZakres (0,0005 – 0,05) g/m3\nMetoda grawimetryczna","reference":"PN-EN ISO 13284-1:2018-02","norm_bases":["PN-EN ISO 13284-1:2018-02"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (0,0005 – 0,05) g/m3\nMetoda grawimetryczna PN-EN ISO 13284-1:2018-02 Gazy odlotowe Stezenie pylu\nZakres (0,0005 – 0,05) g/m3\nMetoda grawimetryczna PN-EN ISO 13284-1:2018-02","categories":["other"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"(0,0005 – 0,05) g/m3"}],"regulatory_area_en":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Dust concentration Gravimetric method Environmental Protection Laboratory Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range PN-EN ISO 13284-1:2018-02","technique_en":"Gravimetric method","test_object_en":"Waste gases","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,0005 – 0,05) g/m3"}],"search_zh":"废气 粉尘浓度 重量法 环境保护实验室 Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-EN ISO 13284-1:2018-02","technique_zh":"重量法","test_object_zh":"废气","regulatory_area_zh":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","lab_section_zh":"环境保护实验室"},{"_id":"6a7f14241995264369d8e4ee","lab_id":"69ad52a3de79e566650fb588","country":"PL","accr_number":"AB 1089","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja pyłu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-EN ISO 13284-1:2018-02","norm_bases":["PN-EN ISO 13284-1:2018-02"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-EN ISO 13284-1:2018-02 Gazy odlotowe Emisja pylu (z obliczen) PN-EN ISO 13284-1:2018-02","categories":["environment"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Dust emission (calculated)","regulatory_area_en":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Dust emission (calculated) Environmental Protection Laboratory Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN ISO 13284-1:2018-02","test_object_en":"Waste gases","search_zh":"废气 粉尘排放量（计算值） 环境保护实验室 Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN ISO 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）","regulatory_area_zh":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","lab_section_zh":"环境保护实验室"}],"has_pdf":true}