{"lab":{"_id":"69ad52a3de79e566650fb584","accr_number":"AB 1087","country":"PL","accr_body":"PCA","address":"MODLIN IM. PŁK LEK. MIKOŁAJA ZYGMUNTA, KWAŚNIEWSKIEGO, ZESPÓŁ LABORATORYJNY, ul. Leśna 4D","categories":["environment","water","microbiology","food"],"city":"Nowy Dwór Mazowiecki","imported_at":"2026-03-08T10:42:43.265Z","methods_count":69,"name":"WOJSKOWY OŚRODEK MEDYCYNY PREWENCYJNEJ –","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1087.pdf"],"scope_summary":"","search_text":"wojskowy ośrodek medycyny prewencyjnej – modlin im. płk lek. mikołaja zygmunta, kwaśniewskiego, zespół laboratoryjny, ul. leśna 4d other microbiology food pharma water automotive electronics environment metrology materials petro","status":"active","updated_at":"2026-03-08T14:50:15.983Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-14T13:06:33.819Z","parse_date":"2026-08-14T13:06:33.819Z","parse_source":"agent-claude-code","email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%201087,podmiot.html","fields_of_testing":[{"codes":"B/3","pl":"Badania biologiczne obiektów i materiałów biologicznych przeznaczonych do badań","en":""},{"codes":"C/33/P","pl":"Badania chemiczne i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Chemical tests and sampling – working environment (harmful factors - air)"},{"codes":"C/29","pl":"Badania chemiczne wody do spożycia przez ludzi","en":"Chemical tests of drinking water"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe – pole elektromagnetyczne, hałas)","en":"Tests concerning environmental engineering (environmental and climatic) – workplace (harmful factors – electromagnetic field, noise)"},{"codes":"K/3, K/22, K/28, K/29","pl":"Badania mikrobiologiczne: obiektów i materiałów biologicznych do badań, żywności, wody, wody do spożycia przez ludzi","en":"Microbiological tests of biological items and materials for testing, food, water, drinking water"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Tests of physical properties and sampling – working environment (harmful factors - air)"},{"codes":"N/22, N/29","pl":"Badania właściwości fizycznych żywności, wody do spożycia przez ludzi","en":"Tests of physical properties of food, drinking water"},{"codes":"O/17","pl":"Badania radiochemiczne i promieniowania – wyroby inne – dawkomierze","en":"Radiochemical tests and tests of radiation – other products - dosimeters"}],"issue":{"no":"19","date":"31.07.2026"},"map_coord":[52.421676,20.741492],"map_geo":"nominatim-street","lab_locations":[{"name":"ZESPÓŁ LABORATORYJNY","address":"ul. Leśna 4D","city":null,"postal":null},{"name":"Laboratorium Badań Żywności i Wody","address":"ul. Leśna 4D, 05-100 Nowy Dwór Mazowiecki","city":"Nowy Dwór Mazowiecki","postal":"05-100"},{"name":"Laboratorium Badań Środowiska Pracy","address":"ul. Leśna 4D, 05-100 Nowy Dwór Mazowiecki","city":"Nowy Dwór Mazowiecki","postal":"05-100"},{"name":"Laboratorium Mikrobiologiczne","address":"ul. Leśna 4D, 05-100 Nowy Dwór Mazowiecki","city":"Nowy Dwór Mazowiecki","postal":"05-100"},{"name":"Laboratorium Higieny Radiacyjnej","address":"ul. Leśna 4D, 05-100 Nowy Dwór Mazowiecki","city":"Nowy Dwór Mazowiecki","postal":"05-100"},{"name":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","address":null,"city":null,"postal":null},{"name":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","address":null,"city":null,"postal":null},{"name":"Zespół Laboratoryjny; Laboratorium Higieny Radiacyjnej","address":null,"city":null,"postal":null},{"name":"Zespół Laboratoryjny; Laboratorium Mikrobiologiczne","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/14/b7706c438beeeeda3b6a4d8cbb1ebe60/AB%201087.pdf","has_en":true,"category_counts":{"environment":32,"water":18,"microbiology":13,"food":10,"other":5,"automotive":3,"materials":2},"category_scores":{"environment":12.34,"water":3.9,"microbiology":2.04,"food":1.2,"other":0.3,"automotive":0.11,"materials":0.05},"has_zh":true,"lab_locations_zh":[{"name":"ZESPÓŁ LABORATORYJNY","address":"ul. Leśna 4D","city":null,"postal":null},{"name":"Laboratorium Badań Żywności i Wody","address":"ul. Leśna 4D, 05-100 Nowy Dwór Mazowiecki","city":"Nowy Dwór Mazowiecki","postal":"05-100"},{"name":"工作场所环境检测实验室","address":"ul. Leśna 4D, 05-100 Nowy Dwór Mazowiecki","city":"Nowy Dwór Mazowiecki","postal":"05-100"},{"name":"微生物实验室","address":"ul. Leśna 4D, 05-100 Nowy Dwór Mazowiecki","city":"Nowy Dwór Mazowiecki","postal":"05-100"},{"name":"Laboratorium Higieny Radiacyjnej","address":"ul. Leśna 4D, 05-100 Nowy Dwór Mazowiecki","city":"Nowy Dwór Mazowiecki","postal":"05-100"},{"name":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","address":null,"city":null,"postal":null},{"name":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","address":null,"city":null,"postal":null},{"name":"Zespół Laboratoryjny; Laboratorium Higieny Radiacyjnej","address":null,"city":null,"postal":null},{"name":"Zespół Laboratoryjny; Laboratorium Mikrobiologiczne","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7f12da1995264369d8e43e","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Mięso i przetwory mięsne, Mleko i przetwory mleczne","methodology":"Obecność Salmonella spp.","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579-1:2017-04 + A1:2020-09","norm_bases":["PN-EN ISO 6579-1:2017-04 + A1:2020-09"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne, Mleko i przetwory mleczne Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 + A1:2020-09 Mieso i przetwory miesne, Mleko i przetwory mleczne Obecnosc Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 + A1:2020-09","categories":["food","microbiology"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Salmonella spp.","search_en":"Meat and meat products, Milk and dairy products Presence of Salmonella spp. Culture method with biochemical and serological confirmation PN-EN ISO 6579-1:2017-04 + A1:2020-09","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Meat and meat products, Milk and dairy products","methodology_zh":"沙门氏菌属（Salmonella spp.）的检出","search_zh":"肉与肉制品、乳与乳制品 沙门氏菌属（Salmonella spp.）的检出 培养法结合生化与血清学确认 PN-EN ISO 6579-1:2017-04 + A1:2020-09","technique_zh":"培养法结合生化与血清学确认","test_object_zh":"肉与肉制品、乳与乳制品"},{"_id":"6a7f12da1995264369d8e43f","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Mięso i przetwory mięsne, Mleko i przetwory mleczne","methodology":"Obecność gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków)","parameters":[],"technique":"Metoda hodowlana probówkowa z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana probówkowa z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków)\nMetoda hodowlana probówkowa z potwierdzeniem biochemicznym","reference":"PN-EN ISO 6888-3:2004+AC:2005","norm_bases":["PN-EN ISO 6888-3:2004+AC:2005"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne, Mleko i przetwory mleczne Obecność gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków)\nMetoda hodowlana probówkowa z potwierdzeniem biochemicznym PN-EN ISO 6888-3:2004+AC:2005 Mieso i przetwory miesne, Mleko i przetwory mleczne Obecnosc gronkowcow koagulazo-dodatnich (Staphylococcus aureus i innych gatunkow)\nMetoda hodowlana probowkowa z potwierdzeniem biochemicznym PN-EN ISO 6888-3:2004+AC:2005","categories":["food"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of coagulase-positive staphylococci (Staphylococcus aureus and other species)","search_en":"Meat and meat products, Milk and dairy products Presence of coagulase-positive staphylococci (Staphylococcus aureus and other species) Tube culture method with biochemical confirmation PN-EN ISO 6888-3:2004+AC:2005","technique_en":"Tube culture method with biochemical confirmation","test_object_en":"Meat and meat products, Milk and dairy products","search_zh":"肉与肉制品、乳与乳制品 凝固酶阳性葡萄球菌（金黄色葡萄球菌及其他菌种）的检出 试管培养法（附生化确证） PN-EN ISO 6888-3:2004+AC:2005","technique_zh":"试管培养法（附生化确证）","test_object_zh":"肉与肉制品、乳与乳制品","methodology_zh":"凝固酶阳性葡萄球菌（金黄色葡萄球菌及其他菌种）的检出"},{"_id":"6a7f12da1995264369d8e440","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Mięso i przetwory mięsne, Mleko i przetwory mleczne","methodology":"Liczba gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków)","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków)\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6888-2:2022-03 + A1:2024-02","norm_bases":["PN-EN ISO 6888-2:2022-03 + A1:2024-02"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne, Mleko i przetwory mleczne Liczba gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków)\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6888-2:2022-03 + A1:2024-02 Mieso i przetwory miesne, Mleko i przetwory mleczne Liczba gronkowcow koagulazo-dodatnich (Staphylococcus aureus i innych gatunkow)\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6888-2:2022-03 + A1:2024-02","categories":["food"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coagulase-positive staphylococci count (Staphylococcus aureus and other species)","search_en":"Meat and meat products, Milk and dairy products Coagulase-positive staphylococci count (Staphylococcus aureus and other species) Plate method (pour plate) PN-EN ISO 6888-2:2022-03 + A1:2024-02","technique_en":"Plate method (pour plate)","test_object_en":"Meat and meat products, Milk and dairy products","search_zh":"肉与肉制品、乳与乳制品 凝固酶阳性葡萄球菌数（金黄色葡萄球菌及其他菌种） 平板法（倾注培养） PN-EN ISO 6888-2:2022-03 + A1:2024-02","technique_zh":"平板法（倾注培养）","methodology_zh":"凝固酶阳性葡萄球菌数（金黄色葡萄球菌及其他菌种）","test_object_zh":"肉与肉制品、乳与乳制品"},{"_id":"6a7f12da1995264369d8e441","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Mięso i przetwory mięsne, Mleko i przetwory mleczne","methodology":"Obecność Listeria monocytogenes","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 11290-1:2017-07","norm_bases":["PN-EN ISO 11290-1:2017-07"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne, Mleko i przetwory mleczne Obecność Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290-1:2017-07 Mieso i przetwory miesne, Mleko i przetwory mleczne Obecnosc Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290-1:2017-07","categories":["food","microbiology"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Listeria monocytogenes","search_en":"Meat and meat products, Milk and dairy products Presence of Listeria monocytogenes Culture method with biochemical confirmation PN-EN ISO 11290-1:2017-07","technique_en":"Culture method with biochemical confirmation","test_object_en":"Meat and meat products, Milk and dairy products","search_zh":"肉与肉制品、乳与乳制品 单核细胞增生李斯特氏菌的检出 培养法结合生化确认 PN-EN ISO 11290-1:2017-07","technique_zh":"培养法结合生化确认","methodology_zh":"单核细胞增生李斯特氏菌的检出","test_object_zh":"肉与肉制品、乳与乳制品"},{"_id":"6a7f12da1995264369d8e442","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Mięso i przetwory mięsne, Mleko i przetwory mleczne","methodology":"Liczba Listeria monocytogenes","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba Listeria monocytogenes\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 11290-2:2017-07","norm_bases":["PN-EN ISO 11290-2:2017-07"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne, Mleko i przetwory mleczne Liczba Listeria monocytogenes\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 11290-2:2017-07 Mieso i przetwory miesne, Mleko i przetwory mleczne Liczba Listeria monocytogenes\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 11290-2:2017-07","categories":["food","microbiology"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Listeria monocytogenes count","search_en":"Meat and meat products, Milk and dairy products Listeria monocytogenes count Plate method (spread plate) PN-EN ISO 11290-2:2017-07","technique_en":"Plate method (spread plate)","test_object_en":"Meat and meat products, Milk and dairy products","search_zh":"肉与肉制品、乳与乳制品 单核细胞增生李斯特氏菌计数 平板法（表面涂布） PN-EN ISO 11290-2:2017-07","technique_zh":"平板法（表面涂布）","methodology_zh":"单核细胞增生李斯特氏菌计数","test_object_zh":"肉与肉制品、乳与乳制品"},{"_id":"6a7f12da1995264369d8e443","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Przetwory mięsne, konserwy mięsne i warzywno-mięsne, Mleko i przetwory mleczne, Przetwory rybne, konserwy rybne","methodology":"Liczba β-glukuronidazo-dodatnich Escherichia coli","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba β-glukuronidazo-dodatnich Escherichia coli\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 16649-2:2004","norm_bases":["PN-ISO 16649-2:2004"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory mięsne, konserwy mięsne i warzywno-mięsne, Mleko i przetwory mleczne, Przetwory rybne, konserwy rybne Liczba β-glukuronidazo-dodatnich Escherichia coli\nMetoda płytkowa (posiew wgłębny) PN-ISO 16649-2:2004 Przetwory miesne, konserwy miesne i warzywno-miesne, Mleko i przetwory mleczne, Przetwory rybne, konserwy rybne Liczba β-glukuronidazo-dodatnich Escherichia coli\nMetoda plytkowa (posiew wglebny) PN-ISO 16649-2:2004","categories":["food","microbiology"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of β-glucuronidase-positive Escherichia coli","search_en":"Count of β-glucuronidase-positive Escherichia coli Plate method (pour plate) PN-ISO 16649-2:2004","technique_en":"Plate method (pour plate)","search_zh":"平板法（倾注培养） PN-ISO 16649-2:2004","technique_zh":"平板法（倾注培养）"},{"_id":"6a7f12da1995264369d8e444","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Przetwory mięsne, konserwy mięsne i warzywno-mięsne, Mleko i przetwory mleczne, Przetwory rybne, konserwy rybne","methodology":"Liczba bakterii z grupy coli","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba bakterii z grupy coli\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 4832:2007","norm_bases":["PN-ISO 4832:2007"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory mięsne, konserwy mięsne i warzywno-mięsne, Mleko i przetwory mleczne, Przetwory rybne, konserwy rybne Liczba bakterii z grupy coli\nMetoda płytkowa (posiew wgłębny) PN-ISO 4832:2007 Przetwory miesne, konserwy miesne i warzywno-miesne, Mleko i przetwory mleczne, Przetwory rybne, konserwy rybne Liczba bakterii z grupy coli\nMetoda plytkowa (posiew wglebny) PN-ISO 4832:2007","categories":["food","microbiology"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Coliform bacteria count Plate method (pour plate) PN-ISO 4832:2007","technique_en":"Plate method (pour plate)","search_zh":"大肠菌群计数 平板法（倾注培养） PN-ISO 4832:2007","technique_zh":"平板法（倾注培养）","methodology_zh":"大肠菌群计数"},{"_id":"6a7f12da1995264369d8e445","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Przetwory mięsne, konserwy mięsne i warzywno-mięsne, Mleko i przetwory mleczne, Przetwory rybne, konserwy rybne","methodology":"Ogólna liczba drobnoustrojów tlenowych","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba drobnoustrojów tlenowych\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 4833-1: 2013-12+Ap1:2016-11+A1:2022-06","norm_bases":["PN-EN ISO 4833-1: 2013-12+Ap1:2016-11+A1:2022-06"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory mięsne, konserwy mięsne i warzywno-mięsne, Mleko i przetwory mleczne, Przetwory rybne, konserwy rybne Ogólna liczba drobnoustrojów tlenowych\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 4833-1: 2013-12+Ap1:2016-11+A1:2022-06 Przetwory miesne, konserwy miesne i warzywno-miesne, Mleko i przetwory mleczne, Przetwory rybne, konserwy rybne Ogolna liczba drobnoustrojow tlenowych\nMetoda plytkowa (posiew wglebny) PN-EN ISO 4833-1: 2013-12+Ap1:2016-11+A1:2022-06","categories":["food","microbiology"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total aerobic viable count","search_en":"Total aerobic viable count Plate method (pour plate) PN-EN ISO 4833-1: 2013-12+Ap1:2016-11+A1:2022-06","technique_en":"Plate method (pour plate)","search_zh":"需氧微生物总数 平板法（倾注培养） PN-EN ISO 4833-1: 2013-12+Ap1:2016-11+A1:2022-06","technique_zh":"平板法（倾注培养）","methodology_zh":"需氧微生物总数"},{"_id":"6a7f12da1995264369d8e446","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Konserwy – mięso i przetwory mięsne","methodology":"Trwałość konserw","parameters":[],"technique":"Metoda termostatowa","techniques":["Metoda termostatowa"],"computed":[],"activity":"Trwałość konserw\nMetoda termostatowa","reference":"PN-A-82055-5: 1994","norm_bases":["PN-A-82055-5: 1994"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Konserwy – mięso i przetwory mięsne Trwałość konserw\nMetoda termostatowa PN-A-82055-5: 1994 Konserwy – mieso i przetwory miesne Trwalosc konserw\nMetoda termostatowa PN-A-82055-5: 1994","categories":["food"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Shelf stability of canned products","search_en":"Canned products – meat and meat products Shelf stability of canned products Thermostatic method PN-A-82055-5: 1994","technique_en":"Thermostatic method","test_object_en":"Canned products – meat and meat products","methodology_zh":"罐头保存性","search_zh":"罐头保存性 恒温培养法 PN-A-82055-5: 1994","technique_zh":"恒温培养法"},{"_id":"6a7f12da1995264369d8e447","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Konserwy – mięso i przetwory mięsne","methodology":"Szczelność konserw","parameters":[],"technique":"Metoda próżniowa","techniques":["Metoda próżniowa"],"computed":[],"activity":"Szczelność konserw\nMetoda próżniowa","reference":"PN-A-82055-4: 1997 pkt 2.4.1.2 + Az1:2002","norm_bases":["PN-A-82055-4: 1997 pkt 2.4.1.2 + Az1:2002"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Konserwy – mięso i przetwory mięsne Szczelność konserw\nMetoda próżniowa PN-A-82055-4: 1997 pkt 2.4.1.2 + Az1:2002 Konserwy – mieso i przetwory miesne Szczelnosc konserw\nMetoda prozniowa PN-A-82055-4: 1997 pkt 2.4.1.2 + Az1:2002","categories":["food"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Tightness of canned products","search_en":"Canned products – meat and meat products Tightness of canned products Vacuum method PN-A-82055-4: 1997 pkt 2.4.1.2 + Az1:2002","technique_en":"Vacuum method","test_object_en":"Canned products – meat and meat products","search_zh":"真空法 PN-A-82055-4: 1997 pkt 2.4.1.2 + Az1:2002","technique_zh":"真空法"},{"_id":"6a7f12da1995264369d8e448","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Konserwy warzywno – mięsne, warzywne, owocowe","methodology":"Szczelność konserw","parameters":[],"technique":"Metoda próżniowa","techniques":["Metoda próżniowa"],"computed":[],"activity":"Szczelność konserw\nMetoda próżniowa","reference":"PN -90/A-75052/02 pkt. 2.2.2","norm_bases":["PN -90/A-75052/02 pkt. 2.2.2"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Konserwy warzywno – mięsne, warzywne, owocowe Szczelność konserw\nMetoda próżniowa PN -90/A-75052/02 pkt. 2.2.2 Konserwy warzywno – miesne, warzywne, owocowe Szczelnosc konserw\nMetoda prozniowa PN -90/A-75052/02 pkt. 2.2.2","categories":["other"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Tightness of canned products","search_en":"Canned vegetable – meat, vegetable and fruit products Tightness of canned products Vacuum method PN -90/A-75052/02 pkt. 2.2.2","technique_en":"Vacuum method","test_object_en":"Canned vegetable – meat, vegetable and fruit products","search_zh":"蔬菜肉类罐头、蔬菜罐头、水果罐头 真空法 PN -90/A-75052/02 pkt. 2.2.2","technique_zh":"真空法","test_object_zh":"蔬菜肉类罐头、蔬菜罐头、水果罐头"},{"_id":"6a7f12da1995264369d8e449","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Konserwy warzywno – mięsne, warzywne, owocowe","methodology":"Trwałość konserw","parameters":[],"technique":"Metoda termostatowa","techniques":["Metoda termostatowa"],"computed":[],"activity":"Trwałość konserw\nMetoda termostatowa","reference":"PN-90/A-75052/03","norm_bases":["PN-90/A-75052/03"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Konserwy warzywno – mięsne, warzywne, owocowe Trwałość konserw\nMetoda termostatowa PN-90/A-75052/03 Konserwy warzywno – miesne, warzywne, owocowe Trwalosc konserw\nMetoda termostatowa PN-90/A-75052/03","categories":["other"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Shelf stability of canned products","search_en":"Canned vegetable – meat, vegetable and fruit products Shelf stability of canned products Thermostatic method PN-90/A-75052/03","technique_en":"Thermostatic method","test_object_en":"Canned vegetable – meat, vegetable and fruit products","methodology_zh":"罐头保存性","search_zh":"蔬菜肉类罐头、蔬菜罐头、水果罐头 罐头保存性 恒温培养法 PN-90/A-75052/03","technique_zh":"恒温培养法","test_object_zh":"蔬菜肉类罐头、蔬菜罐头、水果罐头"},{"_id":"6a7f12da1995264369d8e44a","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Konserwy rybne","methodology":"Szczelność konserw","parameters":[],"technique":"Metoda próżniowa","techniques":["Metoda próżniowa"],"computed":[],"activity":"Szczelność konserw\nMetoda próżniowa","reference":"PN-92/A-86732 pkt.2.3.10","norm_bases":["PN-92/A-86732 pkt.2.3.10"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Konserwy rybne Szczelność konserw\nMetoda próżniowa PN-92/A-86732 pkt.2.3.10 Konserwy rybne Szczelnosc konserw\nMetoda prozniowa PN-92/A-86732 pkt.2.3.10","categories":["other"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Tightness of canned products","search_en":"Canned fish Tightness of canned products Vacuum method PN-92/A-86732 pkt.2.3.10","technique_en":"Vacuum method","test_object_en":"Canned fish","search_zh":"鱼罐头 真空法 PN-92/A-86732 pkt.2.3.10","technique_zh":"真空法","test_object_zh":"鱼罐头"},{"_id":"6a7f12da1995264369d8e44b","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Konserwy rybne","methodology":"Trwałość konserw","parameters":[],"technique":"Metoda termostatowa","techniques":["Metoda termostatowa"],"computed":[],"activity":"Trwałość konserw\nMetoda termostatowa","reference":"PN-92/A-86732 pkt.2.3.11","norm_bases":["PN-92/A-86732 pkt.2.3.11"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Konserwy rybne Trwałość konserw\nMetoda termostatowa PN-92/A-86732 pkt.2.3.11 Konserwy rybne Trwalosc konserw\nMetoda termostatowa PN-92/A-86732 pkt.2.3.11","categories":["other"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Shelf stability of canned products","search_en":"Canned fish Shelf stability of canned products Thermostatic method PN-92/A-86732 pkt.2.3.11","technique_en":"Thermostatic method","test_object_en":"Canned fish","methodology_zh":"罐头保存性","search_zh":"鱼罐头 罐头保存性 恒温培养法 PN-92/A-86732 pkt.2.3.11","test_object_zh":"鱼罐头","technique_zh":"恒温培养法"},{"_id":"6a7f12da1995264369d8e44c","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temperaturze 22ºC","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temperaturze 22ºC\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temperaturze 22ºC\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temperaturze 22ºC\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water intended for human consumption Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水"},{"_id":"6a7f12da1995264369d8e44d","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Intestinal enterococci count","search_en":"Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","methodology_zh":"粪肠球菌计数","search_zh":"生活饮用水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a7f12da1995264369d8e44e","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","methodology_zh":"大肠菌群计数","search_zh":"生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a7f12da1995264369d8e44f","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach","methodology":"Ogólna liczba mikroorganizmów w temperaturze 36ºC","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temperaturze 36ºC\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach Ogólna liczba mikroorganizmów w temperaturze 36ºC\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi, Woda na plywalniach Ogolna liczba mikroorganizmow w temperaturze 36ºC\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water intended for human consumption, Swimming pool water Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water intended for human consumption, Swimming pool water","search_zh":"生活饮用水、游泳池水 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水、游泳池水"},{"_id":"6a7f12da1995264369d8e450","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda do spozycia przez ludzi, Woda na plywalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count","search_en":"Water intended for human consumption, Swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption, Swimming pool water","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"生活饮用水、游泳池水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水、游泳池水"},{"_id":"6a7f12da1995264369d8e451","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda do spozycia przez ludzi, Woda na plywalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pseudomonas aeruginosa count","search_en":"Water intended for human consumption, Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption, Swimming pool water","methodology_zh":"铜绿假单胞菌计数","search_zh":"生活饮用水、游泳池水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"生活饮用水、游泳池水"},{"_id":"6a7f12da1995264369d8e452","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach","methodology":"Liczba bakterii Legionella, Matryca B, Procedura 7 (pożywka C-GVPC)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii Legionella, Matryca B, Procedura 7 (pożywka C-GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 +AP1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 +AP1:2019-12"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach Liczba bakterii Legionella, Matryca B, Procedura 7 (pożywka C-GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +AP1:2019-12 Woda do spozycia przez ludzi, Woda na plywalniach Liczba bakterii Legionella, Matryca B, Procedura 7 (pozywka C-GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +AP1:2019-12","categories":["microbiology","water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water intended for human consumption, Swimming pool water Membrane filtration method PN-EN ISO 11731:2017-08 +AP1:2019-12","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption, Swimming pool water","search_zh":"生活饮用水、游泳池水 膜过滤法 PN-EN ISO 11731:2017-08 +AP1:2019-12","technique_zh":"膜过滤法","test_object_zh":"生活饮用水、游泳池水"},{"_id":"6a7f12da1995264369d8e453","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba gronkowców koagulazo - dodatnich","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba gronkowców koagulazo - dodatnich\nMetoda filtracji membranowej","reference":"PB-01-PM wyd. II z dn. 06.06.2019 r. opracowana na podstawie metodyki NIZP-PZH ZHK:2007","norm_bases":["PB-01-PM wyd. II z dn. 06.06.2019 r. opracowana na podstawie metodyki NIZP-PZH ZHK:2007"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba gronkowców koagulazo - dodatnich\nMetoda filtracji membranowej PB-01-PM wyd. II z dn. 06.06.2019 r. opracowana na podstawie metodyki NIZP-PZH ZHK:2007 Woda na plywalniach Liczba gronkowcow koagulazo - dodatnich\nMetoda filtracji membranowej PB-01-PM wyd. II z dn. 06.06.2019 r. opracowana na podstawie metodyki NIZP-PZH ZHK:2007","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coagulase-positive staphylococci count","search_en":"Swimming pool water Coagulase-positive staphylococci count Membrane filtration method PB-01-PM wyd. II z dn. 06.06.2019 r. opracowana na podstawie metodyki NIZP-PZH ZHK:2007","technique_en":"Membrane filtration method","test_object_en":"Swimming pool water","search_zh":"游泳池水 凝固酶阳性葡萄球菌数 膜过滤法 PB-01-PM wyd. II z dn. 06.06.2019 r. opracowana na podstawie metodyki NIZP-PZH ZHK:2007","technique_zh":"膜过滤法","test_object_zh":"游泳池水","methodology_zh":"凝固酶阳性葡萄球菌数"},{"_id":"6a7f12da1995264369d8e454","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(2 – 70) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (2 – 70) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","norm_bases":["PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Barwa\nZakres (2 – 70) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C Woda do spozycia przez ludzi Barwa\nZakres (2 – 70) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(2 – 70) mg/l Pt"}],"search_en":"Water intended for human consumption Colour Spectrophotometric method Range PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(2 – 70) mg/l Pt"}],"search_zh":"生活饮用水 色度 分光光度法 范围 PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a7f12da1995264369d8e455","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 – 10) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 – 10) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Mętność\nZakres (0,10 – 10) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda do spozycia przez ludzi Metnosc\nZakres (0,10 – 10) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,10 – 10) NTU"}],"search_en":"Water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 – 10) NTU"}],"search_zh":"生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"生活饮用水"},{"_id":"6a7f12da1995264369d8e456","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda do spozycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Water intended for human consumption pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water intended for human consumption","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"生活饮用水"},{"_id":"6a7f12da1995264369d8e457","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(84 – 2500) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (84 – 2500) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (84 – 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (84 – 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(84 – 2500) μS/cm"}],"search_en":"Water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water intended for human consumption","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(84 – 2500) μS/cm"}],"search_zh":"生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"生活饮用水"},{"_id":"6a7f12da1995264369d8e458","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5 – 300) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5 – 300) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie chlorków\nZakres (5 – 300) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda do spozycia przez ludzi Stezenie chlorkow\nZakres (5 – 300) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5 – 300) mg/l"}],"search_en":"Water intended for human consumption Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 – 300) mg/l"}],"search_zh":"生活饮用水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"生活饮用水"},{"_id":"6a7f12da1995264369d8e459","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(5 – 500) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5 – 500) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (5 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(5 – 500) mg/l CaCO3"}],"search_en":"Water intended for human consumption Total content of calcium and magnesium (total hardness) Titrimetric method Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(5 – 500) mg/l CaCO3"}],"search_zh":"生活饮用水 钙与镁总量（总硬度） 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"生活饮用水"},{"_id":"6a7f12da1995264369d8e45a","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,010 -0,6) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,010 -0,6) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,010 -0,6) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,010 -0,6) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,010 -0,6) mg/l"}],"search_en":"Water intended for human consumption Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,010 -0,6) mg/l"}],"search_zh":"生活饮用水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a7f12da1995264369d8e45b","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(30-3000) µg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (30-3000) µg/l\nMetoda spektrofotometryczna","reference":"Metoda HACH LANGE Nr 8008 Wydanie I z 09.2005 r.","norm_bases":["Metoda HACH LANGE Nr 8008 Wydanie I z 09.2005 r."],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie żelaza\nZakres (30-3000) µg/l\nMetoda spektrofotometryczna Metoda HACH LANGE Nr 8008 Wydanie I z 09.2005 r. Woda do spozycia przez ludzi Stezenie zelaza\nZakres (30-3000) µg/l\nMetoda spektrofotometryczna Metoda HACH LANGE Nr 8008 Wydanie I z 09.2005 r.","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(30-3000) µg/l"}],"search_en":"Water intended for human consumption Iron concentration Spectrophotometric method Range Metoda HACH LANGE Nr 8008 Wydanie I z 09.2005 r.","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(30-3000) µg/l"}],"search_zh":"生活饮用水 铁浓度 分光光度法 范围 Metoda HACH LANGE Nr 8008 Wydanie I z 09.2005 r.","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a7f12da1995264369d8e45c","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(9 – 700) µg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (9 – 700) µg/l\nMetoda spektrofotometryczna","reference":"Metoda HACH LANGE Nr 8149 Wydanie I z 04.2005 r.","norm_bases":["Metoda HACH LANGE Nr 8149 Wydanie I z 04.2005 r."],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie manganu\nZakres (9 – 700) µg/l\nMetoda spektrofotometryczna Metoda HACH LANGE Nr 8149 Wydanie I z 04.2005 r. Woda do spozycia przez ludzi Stezenie manganu\nZakres (9 – 700) µg/l\nMetoda spektrofotometryczna Metoda HACH LANGE Nr 8149 Wydanie I z 04.2005 r.","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(9 – 700) µg/l"}],"search_en":"Water intended for human consumption Manganese concentration Spectrophotometric method Range Metoda HACH LANGE Nr 8149 Wydanie I z 04.2005 r.","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(9 – 700) µg/l"}],"search_zh":"生活饮用水 锰浓度 分光光度法 范围 Metoda HACH LANGE Nr 8149 Wydanie I z 04.2005 r.","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a7f12da1995264369d8e45d","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie metali","parameters":[{"name":"Chrom","range":"(10 – 100) µg/l"},{"name":"Mangan","range":"(10 – 500) µg/l"},{"name":"Żelazo","range":"(20 – 700) µg/l"},{"name":"Miedź","range":"(0,030 – 2,0) mg/l"},{"name":"Glin","range":"(30 – 500) µg/l"},{"name":"Kadm","range":"(1,0 – 10) µg/l"},{"name":"Nikiel","range":"(5 – 40) µg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plaźmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plaźmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie metali\nZakres:\nChrom (10 – 100) µg/l\nMangan (10 – 500) µg/l\nŻelazo (20 – 700) µg/l\nMiedź (0,030 – 2,0) mg/l\nGlin (30 – 500) µg/l\nKadm (1,0 – 10) µg/l\nNikiel (5 – 40) µg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plaźmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Żywności i Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie metali\nZakres:\nChrom (10 – 100) µg/l\nMangan (10 – 500) µg/l\nŻelazo (20 – 700) µg/l\nMiedź (0,030 – 2,0) mg/l\nGlin (30 – 500) µg/l\nKadm (1,0 – 10) µg/l\nNikiel (5 – 40) µg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plaźmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda do spozycia przez ludzi Stezenie metali\nZakres:\nChrom (10 – 100) µg/l\nMangan (10 – 500) µg/l\nZelazo (20 – 700) µg/l\nMiedz (0,030 – 2,0) mg/l\nGlin (30 – 500) µg/l\nKadm (1,0 – 10) µg/l\nNikiel (5 – 40) µg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["materials","water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations","parameters_en":[{"name":"Chromium","range":"(10 – 100) µg/l"},{"name":"Manganese","range":"(10 – 500) µg/l"},{"name":"Iron","range":"(20 – 700) µg/l"},{"name":"Copper","range":"(0,030 – 2,0) mg/l"},{"name":"Aluminium","range":"(30 – 500) µg/l"},{"name":"Cadmium","range":"(1,0 – 10) µg/l"},{"name":"Nickel","range":"(5 – 40) µg/l"}],"search_en":"Water intended for human consumption Metal concentrations Chromium Manganese Iron Copper Aluminium Cadmium Nickel PN-EN ISO 11885:2009","test_object_en":"Water intended for human consumption","methodology_zh":"金属浓度","parameters_zh":[{"name":"铬","range":"(10 – 100) µg/l"},{"name":"锰","range":"(10 – 500) µg/l"},{"name":"铁","range":"(20 – 700) µg/l"},{"name":"铜","range":"(0,030 – 2,0) mg/l"},{"name":"铝","range":"(30 – 500) µg/l"},{"name":"镉","range":"(1,0 – 10) µg/l"},{"name":"镍","range":"(5 – 40) µg/l"}],"search_zh":"生活饮用水 金属浓度 铬 锰 铁 铜 铝 镉 镍 PN-EN ISO 11885:2009","test_object_zh":"生活饮用水"},{"_id":"6a7f12da1995264369d8e45e","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń radiolokacyjnych","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 800 MHz do 18 GHz"},{"name":"Zakres","range":"(5 - 600) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 800 MHz do 18 GHz\nZakres (5 - 600) V/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","norm_bases":["NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów Decyzji Nr 171/MON Ministra Obrony Narodowej z dnia 27.10.2017 r. (Dz.Urz. MON z 2017 r. poz. 208 z późn. zm.).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń radiolokacyjnych Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 800 MHz do 18 GHz\nZakres (5 - 600) V/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen radiolokacyjnych Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 800 MHz do 18 GHz\nZakres (5 - 600) V/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022 Bezpieczenstwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Czesc 2: Metody badan","categories":["environment"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range","range":"od 800 MHz do 18 GHz"},{"name":"Range","range":"(5 - 600) V/m"}],"search_en":"Workplace environment - electromagnetic field in the workspace originating from radar equipment Electric field strength: Direct measurement method in the frequency range Range NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field in the workspace originating from radar equipment","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围","range":"od 800 MHz do 18 GHz"},{"name":"范围","range":"(5 - 600) V/m"}],"search_zh":"工作环境 － 作业空间内由雷达设备产生的电磁场 电场强度： 直接测量法 频率范围 范围 NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","technique_zh":"直接测量法","test_object_zh":"工作环境 － 作业空间内由雷达设备产生的电磁场"},{"_id":"6a7f12da1995264369d8e45f","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń radiolokacyjnych","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 800 MHz do 18 GHz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 800 MHz do 18 GHz\n(z obliczeń)","reference":"NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","norm_bases":["NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów Decyzji Nr 171/MON Ministra Obrony Narodowej z dnia 27.10.2017 r. (Dz.Urz. MON z 2017 r. poz. 208 z późn. zm.).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń radiolokacyjnych Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 800 MHz do 18 GHz\n(z obliczeń) NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen radiolokacyjnych Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 800 MHz do 18 GHz\n(z obliczen) NO-06-A215-2:2022 Bezpieczenstwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Czesc 2: Metody badan","categories":["environment"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"od 800 MHz do 18 GHz"},{"name":"(calculated)"}],"search_en":"Workplace environment - electromagnetic field in the workspace originating from radar equipment Magnetic field strength: in the frequency range (calculated) NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","test_object_en":"Workplace environment - electromagnetic field in the workspace originating from radar equipment","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"od 800 MHz do 18 GHz"},{"name":"（计算得出）"}],"search_zh":"工作环境 － 作业空间内由雷达设备产生的电磁场 磁场强度： 频率范围 （计算得出） NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","test_object_zh":"工作环境 － 作业空间内由雷达设备产生的电磁场"},{"_id":"6a7f12da1995264369d8e460","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stacji naprowadzania rakiet","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 800 MHz do 18 GHz"},{"name":"Zakres","range":"(5 - 600) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 800 MHz do 18 GHz\nZakres (5 - 600) V/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","norm_bases":["NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów Decyzji Nr 171/MON Ministra Obrony Narodowej z dnia 27.10.2017 r. (Dz.Urz. MON z 2017 r. poz. 208 z późn. zm.).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stacji naprowadzania rakiet Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 800 MHz do 18 GHz\nZakres (5 - 600) V/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od stacji naprowadzania rakiet Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 800 MHz do 18 GHz\nZakres (5 - 600) V/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022 Bezpieczenstwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Czesc 2: Metody badan","categories":["environment"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range","range":"od 800 MHz do 18 GHz"},{"name":"Range","range":"(5 - 600) V/m"}],"search_en":"Workplace environment - electromagnetic field in the workspace originating from missile guidance stations Electric field strength: Direct measurement method in the frequency range Range NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field in the workspace originating from missile guidance stations","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围","range":"od 800 MHz do 18 GHz"},{"name":"范围","range":"(5 - 600) V/m"}],"search_zh":"工作环境 － 作业空间内由导弹制导站产生的电磁场 电场强度： 直接测量法 频率范围 范围 NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","technique_zh":"直接测量法","test_object_zh":"工作环境 － 作业空间内由导弹制导站产生的电磁场"},{"_id":"6a7f12da1995264369d8e461","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stacji naprowadzania rakiet","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 800 MHz do 18 GHz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 800 MHz do 18 GHz\n(z obliczeń)","reference":"NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","norm_bases":["NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów Decyzji Nr 171/MON Ministra Obrony Narodowej z dnia 27.10.2017 r. (Dz.Urz. MON z 2017 r. poz. 208 z późn. zm.).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stacji naprowadzania rakiet Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 800 MHz do 18 GHz\n(z obliczeń) NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od stacji naprowadzania rakiet Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 800 MHz do 18 GHz\n(z obliczen) NO-06-A215-2:2022 Bezpieczenstwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Czesc 2: Metody badan","categories":["environment"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"od 800 MHz do 18 GHz"},{"name":"(calculated)"}],"search_en":"Workplace environment - electromagnetic field in the workspace originating from missile guidance stations Magnetic field strength: in the frequency range (calculated) NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","test_object_en":"Workplace environment - electromagnetic field in the workspace originating from missile guidance stations","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"od 800 MHz do 18 GHz"},{"name":"（计算得出）"}],"search_zh":"工作环境 － 作业空间内由导弹制导站产生的电磁场 磁场强度： 频率范围 （计算得出） NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","test_object_zh":"工作环境 － 作业空间内由导弹制导站产生的电磁场"},{"_id":"6a7f12da1995264369d8e462","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stacjonarnych urządzeń łączności","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 0,1 MHz do 18 GHz"},{"name":"Zakres","range":"(1 - 1000) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 18 GHz\nZakres (1 - 1000) V/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","norm_bases":["NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów Decyzji Nr 171/MON Ministra Obrony Narodowej z dnia 27.10.2017 r. (Dz.Urz. MON z 2017 r. poz. 208 z późn. zm.).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stacjonarnych urządzeń łączności Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 18 GHz\nZakres (1 - 1000) V/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od stacjonarnych urzadzen lacznosci Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 0,1 MHz do 18 GHz\nZakres (1 - 1000) V/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022 Bezpieczenstwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Czesc 2: Metody badan","categories":["environment"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range","range":"od 0,1 MHz do 18 GHz"},{"name":"Range","range":"(1 - 1000) V/m"}],"search_en":"Workplace environment - electromagnetic field in the workspace from stationary communication equipment Electric field strength: Direct measurement method in the frequency range Range NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field in the workspace from stationary communication equipment","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围","range":"od 0,1 MHz do 18 GHz"},{"name":"范围","range":"(1 - 1000) V/m"}],"search_zh":"工作环境 － 作业空间内由固定式通信设备产生的电磁场 电场强度： 直接测量法 频率范围 范围 NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","technique_zh":"直接测量法","test_object_zh":"工作环境 － 作业空间内由固定式通信设备产生的电磁场"},{"_id":"6a7f12da1995264369d8e463","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stacjonarnych urządzeń łączności","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 0,1 MHz do 800 MHz"},{"name":"Zakres","range":"(0,01 – 15) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 800 MHz\nZakres (0,01 – 15) A/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","norm_bases":["NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów Decyzji Nr 171/MON Ministra Obrony Narodowej z dnia 27.10.2017 r. (Dz.Urz. MON z 2017 r. poz. 208 z późn. zm.).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stacjonarnych urządzeń łączności Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 800 MHz\nZakres (0,01 – 15) A/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od stacjonarnych urzadzen lacznosci Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 0,1 MHz do 800 MHz\nZakres (0,01 – 15) A/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022 Bezpieczenstwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Czesc 2: Metody badan","categories":["environment"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"od 0,1 MHz do 800 MHz"},{"name":"Range","range":"(0,01 – 15) A/m"}],"search_en":"Workplace environment - electromagnetic field in the workspace from stationary communication equipment Magnetic field strength: Direct measurement method in the frequency range Range NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field in the workspace from stationary communication equipment","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"od 0,1 MHz do 800 MHz"},{"name":"范围","range":"(0,01 – 15) A/m"}],"search_zh":"工作环境 － 作业空间内由固定式通信设备产生的电磁场 磁场强度： 直接测量法 频率范围 范围 NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","technique_zh":"直接测量法","test_object_zh":"工作环境 － 作业空间内由固定式通信设备产生的电磁场"},{"_id":"6a7f12da1995264369d8e464","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stacjonarnych urządzeń łączności","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 800 MHz do 18 GHz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 800 MHz do 18 GHz\n(z obliczeń)","reference":"NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","norm_bases":["NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów Decyzji Nr 171/MON Ministra Obrony Narodowej z dnia 27.10.2017 r. (Dz.Urz. MON z 2017 r. poz. 208 z późn. zm.).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stacjonarnych urządzeń łączności Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 800 MHz do 18 GHz\n(z obliczeń) NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od stacjonarnych urzadzen lacznosci Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 800 MHz do 18 GHz\n(z obliczen) NO-06-A215-2:2022 Bezpieczenstwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Czesc 2: Metody badan","categories":["environment"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"od 800 MHz do 18 GHz"},{"name":"(calculated)"}],"search_en":"Workplace environment - electromagnetic field in the workspace from stationary communication equipment Magnetic field strength: in the frequency range (calculated) NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","test_object_en":"Workplace environment - electromagnetic field in the workspace from stationary communication equipment","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"od 800 MHz do 18 GHz"},{"name":"（计算得出）"}],"search_zh":"工作环境 － 作业空间内由固定式通信设备产生的电磁场 磁场强度： 频率范围 （计算得出） NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","test_object_zh":"工作环境 － 作业空间内由固定式通信设备产生的电磁场"},{"_id":"6a7f12da1995264369d8e465","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od mobilnych urządzeń łączności","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 0,1 MHz do 18 GHz"},{"name":"Zakres","range":"(1 - 1000) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 18 GHz\nZakres (1 - 1000) V/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","norm_bases":["NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów Decyzji Nr 171/MON Ministra Obrony Narodowej z dnia 27.10.2017 r. (Dz.Urz. MON z 2017 r. poz. 208 z późn. zm.).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od mobilnych urządzeń łączności Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 18 GHz\nZakres (1 - 1000) V/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od mobilnych urzadzen lacznosci Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 0,1 MHz do 18 GHz\nZakres (1 - 1000) V/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022 Bezpieczenstwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Czesc 2: Metody badan","categories":["environment"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range","range":"od 0,1 MHz do 18 GHz"},{"name":"Range","range":"(1 - 1000) V/m"}],"search_en":"Workplace environment - electromagnetic field in the workspace originating from mobile communication devices Electric field strength: Direct measurement method in the frequency range Range NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field in the workspace originating from mobile communication devices","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围","range":"od 0,1 MHz do 18 GHz"},{"name":"范围","range":"(1 - 1000) V/m"}],"search_zh":"工作环境 － 作业空间内由移动通信设备产生的电磁场 电场强度： 直接测量法 频率范围 范围 NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","technique_zh":"直接测量法","test_object_zh":"工作环境 － 作业空间内由移动通信设备产生的电磁场"},{"_id":"6a7f12da1995264369d8e466","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od mobilnych urządzeń łączności","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 0,1 MHz do 800 MHz"},{"name":"Zakres","range":"(0,01 – 15) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 800 MHz\nZakres (0,01 – 15) A/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","norm_bases":["NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów Decyzji Nr 171/MON Ministra Obrony Narodowej z dnia 27.10.2017 r. (Dz.Urz. MON z 2017 r. poz. 208 z późn. zm.).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od mobilnych urządzeń łączności Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 800 MHz\nZakres (0,01 – 15) A/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od mobilnych urzadzen lacznosci Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 0,1 MHz do 800 MHz\nZakres (0,01 – 15) A/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022 Bezpieczenstwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Czesc 2: Metody badan","categories":["environment"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"od 0,1 MHz do 800 MHz"},{"name":"Range","range":"(0,01 – 15) A/m"}],"search_en":"Workplace environment - electromagnetic field in the workspace originating from mobile communication devices Magnetic field strength: Direct measurement method in the frequency range Range NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field in the workspace originating from mobile communication devices","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"od 0,1 MHz do 800 MHz"},{"name":"范围","range":"(0,01 – 15) A/m"}],"search_zh":"工作环境 － 作业空间内由移动通信设备产生的电磁场 磁场强度： 直接测量法 频率范围 范围 NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","technique_zh":"直接测量法","test_object_zh":"工作环境 － 作业空间内由移动通信设备产生的电磁场"},{"_id":"6a7f12da1995264369d8e467","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od mobilnych urządzeń łączności","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 800 MHz do 18 GHz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 800 MHz do 18 GHz\n(z obliczeń)","reference":"NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","norm_bases":["NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów Decyzji Nr 171/MON Ministra Obrony Narodowej z dnia 27.10.2017 r. (Dz.Urz. MON z 2017 r. poz. 208 z późn. zm.).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od mobilnych urządzeń łączności Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 800 MHz do 18 GHz\n(z obliczeń) NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od mobilnych urzadzen lacznosci Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 800 MHz do 18 GHz\n(z obliczen) NO-06-A215-2:2022 Bezpieczenstwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Czesc 2: Metody badan","categories":["environment"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"od 800 MHz do 18 GHz"},{"name":"(calculated)"}],"search_en":"Workplace environment - electromagnetic field in the workspace originating from mobile communication devices Magnetic field strength: in the frequency range (calculated) NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","test_object_en":"Workplace environment - electromagnetic field in the workspace originating from mobile communication devices","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"od 800 MHz do 18 GHz"},{"name":"（计算得出）"}],"search_zh":"工作环境 － 作业空间内由移动通信设备产生的电磁场 磁场强度： 频率范围 （计算得出） NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","test_object_zh":"工作环境 － 作业空间内由移动通信设备产生的电磁场"},{"_id":"6a7f12da1995264369d8e468","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od pojazdów ze środkami łączności","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 0,1 MHz do 18 GHz"},{"name":"Zakres","range":"(1 - 1000) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 18 GHz\nZakres (1 - 1000) V/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","norm_bases":["NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów Decyzji Nr 171/MON Ministra Obrony Narodowej z dnia 27.10.2017 r. (Dz.Urz. MON z 2017 r. poz. 208 z późn. zm.).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od pojazdów ze środkami łączności Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 18 GHz\nZakres (1 - 1000) V/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od pojazdow ze srodkami lacznosci Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 0,1 MHz do 18 GHz\nZakres (1 - 1000) V/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022 Bezpieczenstwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Czesc 2: Metody badan","categories":["environment","automotive"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range","range":"od 0,1 MHz do 18 GHz"},{"name":"Range","range":"(1 - 1000) V/m"}],"search_en":"Workplace environment - electromagnetic field in the workspace from vehicles with communication equipment Electric field strength: Direct measurement method in the frequency range Range NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field in the workspace from vehicles with communication equipment","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围","range":"od 0,1 MHz do 18 GHz"},{"name":"范围","range":"(1 - 1000) V/m"}],"search_zh":"工作环境 － 作业空间内由载有通信设备的车辆产生的电磁场 电场强度： 直接测量法 频率范围 范围 NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","technique_zh":"直接测量法","test_object_zh":"工作环境 － 作业空间内由载有通信设备的车辆产生的电磁场"},{"_id":"6a7f12da1995264369d8e469","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od pojazdów ze środkami łączności","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 0,1 MHz do 800 MHz"},{"name":"Zakres","range":"(0,01 – 15) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 800 MHz\nZakres (0,01 – 15) A/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","norm_bases":["NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów Decyzji Nr 171/MON Ministra Obrony Narodowej z dnia 27.10.2017 r. (Dz.Urz. MON z 2017 r. poz. 208 z późn. zm.).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od pojazdów ze środkami łączności Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 800 MHz\nZakres (0,01 – 15) A/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od pojazdow ze srodkami lacznosci Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 0,1 MHz do 800 MHz\nZakres (0,01 – 15) A/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022 Bezpieczenstwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Czesc 2: Metody badan","categories":["environment","automotive"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"od 0,1 MHz do 800 MHz"},{"name":"Range","range":"(0,01 – 15) A/m"}],"search_en":"Workplace environment - electromagnetic field in the workspace from vehicles with communication equipment Magnetic field strength: Direct measurement method in the frequency range Range NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field in the workspace from vehicles with communication equipment","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"od 0,1 MHz do 800 MHz"},{"name":"范围","range":"(0,01 – 15) A/m"}],"search_zh":"工作环境 － 作业空间内由载有通信设备的车辆产生的电磁场 磁场强度： 直接测量法 频率范围 范围 NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","technique_zh":"直接测量法","test_object_zh":"工作环境 － 作业空间内由载有通信设备的车辆产生的电磁场"},{"_id":"6a7f12da1995264369d8e46a","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od pojazdów ze środkami łączności","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 800 MHz do 18 GHz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 800 MHz do 18 GHz\n(z obliczeń)","reference":"NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","norm_bases":["NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów Decyzji Nr 171/MON Ministra Obrony Narodowej z dnia 27.10.2017 r. (Dz.Urz. MON z 2017 r. poz. 208 z późn. zm.).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od pojazdów ze środkami łączności Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 800 MHz do 18 GHz\n(z obliczeń) NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od pojazdow ze srodkami lacznosci Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 800 MHz do 18 GHz\n(z obliczen) NO-06-A215-2:2022 Bezpieczenstwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Czesc 2: Metody badan","categories":["environment","automotive"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"od 800 MHz do 18 GHz"},{"name":"(calculated)"}],"search_en":"Workplace environment - electromagnetic field in the workspace from vehicles with communication equipment Magnetic field strength: in the frequency range (calculated) NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","test_object_en":"Workplace environment - electromagnetic field in the workspace from vehicles with communication equipment","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"od 800 MHz do 18 GHz"},{"name":"（计算得出）"}],"search_zh":"工作环境 － 作业空间内由载有通信设备的车辆产生的电磁场 磁场强度： 频率范围 （计算得出） NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","test_object_zh":"工作环境 － 作业空间内由载有通信设备的车辆产生的电磁场"},{"_id":"6a7f12da1995264369d8e46b","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od doręcznych i przenośnych środków łączności","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 0,1 MHz do 800 MHz"},{"name":"Zakres","range":"(1 - 1000) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 800 MHz\nZakres (1 - 1000) V/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","norm_bases":["NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów Decyzji Nr 171/MON Ministra Obrony Narodowej z dnia 27.10.2017 r. (Dz.Urz. MON z 2017 r. poz. 208 z późn. zm.).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od doręcznych i przenośnych środków łączności Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 800 MHz\nZakres (1 - 1000) V/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od dorecznych i przenosnych srodkow lacznosci Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 0,1 MHz do 800 MHz\nZakres (1 - 1000) V/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022 Bezpieczenstwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Czesc 2: Metody badan","categories":["environment"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range","range":"od 0,1 MHz do 800 MHz"},{"name":"Range","range":"(1 - 1000) V/m"}],"search_en":"Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices Electric field strength: Direct measurement method in the frequency range Range NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围","range":"od 0,1 MHz do 800 MHz"},{"name":"范围","range":"(1 - 1000) V/m"}],"search_zh":"工作环境 － 作业空间内由手持式与便携式通信设备产生的电磁场 电场强度： 直接测量法 频率范围 范围 NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","technique_zh":"直接测量法","test_object_zh":"工作环境 － 作业空间内由手持式与便携式通信设备产生的电磁场"},{"_id":"6a7f12da1995264369d8e46c","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od doręcznych i przenośnych środków łączności","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 0,1 MHz do 1 GHz"},{"name":"Zakres","range":"(0,01 – 15) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 1 GHz\nZakres (0,01 – 15) A/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","norm_bases":["NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów Decyzji Nr 171/MON Ministra Obrony Narodowej z dnia 27.10.2017 r. (Dz.Urz. MON z 2017 r. poz. 208 z późn. zm.).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od doręcznych i przenośnych środków łączności Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 1 GHz\nZakres (0,01 – 15) A/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od dorecznych i przenosnych srodkow lacznosci Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 0,1 MHz do 1 GHz\nZakres (0,01 – 15) A/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022 Bezpieczenstwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Czesc 2: Metody badan","categories":["environment"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"od 0,1 MHz do 1 GHz"},{"name":"Range","range":"(0,01 – 15) A/m"}],"search_en":"Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices Magnetic field strength: Direct measurement method in the frequency range Range NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"od 0,1 MHz do 1 GHz"},{"name":"范围","range":"(0,01 – 15) A/m"}],"search_zh":"工作环境 － 作业空间内由手持式与便携式通信设备产生的电磁场 磁场强度： 直接测量法 频率范围 范围 NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","technique_zh":"直接测量法","test_object_zh":"工作环境 － 作业空间内由手持式与便携式通信设备产生的电磁场"},{"_id":"6a7f12da1995264369d8e46d","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stanowisk kontrolno-pomiarowych","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 0,1 MHz do 18 GHz"},{"name":"Zakres","range":"(1 - 1000) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 18 GHz\nZakres (1 - 1000) V/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","norm_bases":["NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów Decyzji Nr 171/MON Ministra Obrony Narodowej z dnia 27.10.2017 r. (Dz.Urz. MON z 2017 r. poz. 208 z późn. zm.).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stanowisk kontrolno-pomiarowych Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 18 GHz\nZakres (1 - 1000) V/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od stanowisk kontrolno-pomiarowych Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 0,1 MHz do 18 GHz\nZakres (1 - 1000) V/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022 Bezpieczenstwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Czesc 2: Metody badan","categories":["environment"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range","range":"od 0,1 MHz do 18 GHz"},{"name":"Range","range":"(1 - 1000) V/m"}],"search_en":"Workplace environment - electromagnetic field in the work space originating from control and measurement stations Electric field strength: Direct measurement method in the frequency range Range NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field in the work space originating from control and measurement stations","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围","range":"od 0,1 MHz do 18 GHz"},{"name":"范围","range":"(1 - 1000) V/m"}],"search_zh":"电场强度： 直接测量法 频率范围 范围 NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","technique_zh":"直接测量法"},{"_id":"6a7f12da1995264369d8e46e","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stanowisk kontrolno-pomiarowych","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 0,1 MHz do 800 MHz"},{"name":"Zakres","range":"(0,01 – 15) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 800 MHz\nZakres (0,01 – 15) A/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","norm_bases":["NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów Decyzji Nr 171/MON Ministra Obrony Narodowej z dnia 27.10.2017 r. (Dz.Urz. MON z 2017 r. poz. 208 z późn. zm.).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stanowisk kontrolno-pomiarowych Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 800 MHz\nZakres (0,01 – 15) A/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od stanowisk kontrolno-pomiarowych Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 0,1 MHz do 800 MHz\nZakres (0,01 – 15) A/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022 Bezpieczenstwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Czesc 2: Metody badan","categories":["environment"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"od 0,1 MHz do 800 MHz"},{"name":"Range","range":"(0,01 – 15) A/m"}],"search_en":"Workplace environment - electromagnetic field in the work space originating from control and measurement stations Magnetic field strength: Direct measurement method in the frequency range Range NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field in the work space originating from control and measurement stations","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"od 0,1 MHz do 800 MHz"},{"name":"范围","range":"(0,01 – 15) A/m"}],"search_zh":"磁场强度： 直接测量法 频率范围 范围 NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","technique_zh":"直接测量法"},{"_id":"6a7f12da1995264369d8e46f","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stanowisk kontrolno-pomiarowych","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 800 MHz do 18 GHz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 800 MHz do 18 GHz\n(z obliczeń)","reference":"NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","norm_bases":["NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów Decyzji Nr 171/MON Ministra Obrony Narodowej z dnia 27.10.2017 r. (Dz.Urz. MON z 2017 r. poz. 208 z późn. zm.).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stanowisk kontrolno-pomiarowych Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 800 MHz do 18 GHz\n(z obliczeń) NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od stanowisk kontrolno-pomiarowych Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 800 MHz do 18 GHz\n(z obliczen) NO-06-A215-2:2022 Bezpieczenstwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Czesc 2: Metody badan","categories":["environment"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"od 800 MHz do 18 GHz"},{"name":"(calculated)"}],"search_en":"Workplace environment - electromagnetic field in the work space originating from control and measurement stations Magnetic field strength: in the frequency range (calculated) NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań","test_object_en":"Workplace environment - electromagnetic field in the work space originating from control and measurement stations","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"od 800 MHz do 18 GHz"},{"name":"（计算得出）"}],"search_zh":"磁场强度： 频率范围 （计算得出） NO-06-A215-2:2022 Bezpieczeństwo i Higiena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań"},{"_id":"6a7f12da1995264369d8e470","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 20 Hz do 50 Hz"},{"name":"Zakres","range":"(0,01 – 50) mT"}],"technique":"Metoda pomiarowa bezpośrednia (uproszczona)","techniques":["Metoda pomiarowa bezpośrednia (uproszczona)"],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 20 Hz do 50 Hz\nZakres (0,01 – 50) mT\nMetoda pomiarowa bezpośrednia (uproszczona)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 20 Hz do 50 Hz\nZakres (0,01 – 50) mT\nMetoda pomiarowa bezpośrednia (uproszczona) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen do magnetoterapii Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 20 Hz do 50 Hz\nZakres (0,01 – 50) mT\nMetoda pomiarowa bezposrednia (uproszczona) Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 151 – 180","categories":["environment"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"od 20 Hz do 50 Hz"},{"name":"Range","range":"(0,01 – 50) mT"}],"search_en":"Workplace environment - electromagnetic field in the workspace from magnetotherapy devices Magnetic field strength: Direct measurement method (simplified) in the frequency range Range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180","technique_en":"Direct measurement method (simplified)","test_object_en":"Workplace environment - electromagnetic field in the workspace from magnetotherapy devices","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"od 20 Hz do 50 Hz"},{"name":"范围","range":"(0,01 – 50) mT"}],"search_zh":"工作场所环境 — 工作空间内来自磁疗设备的电磁场 磁场强度： 直接测量法（简化） 频率范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180","test_object_zh":"工作场所环境 — 工作空间内来自磁疗设备的电磁场","technique_zh":"直接测量法（简化）"},{"_id":"6a7f12da1995264369d8e471","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(44 – 157) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres (44 – 157) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres (44 – 157) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11 Srodowisko pracy - halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres (44 – 157) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 - punkt 10 i 11","categories":["environment"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(44 – 157) dB"}],"search_en":"Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(44 – 157) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a7f12da1995264369d8e472","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Szczytowy poziom dźwięku C","parameters":[{"name":"Zakres","range":"(44 – 157) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Szczytowy poziom dźwięku C\nZakres (44 – 157) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Szczytowy poziom dźwięku C\nZakres (44 – 157) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11 Srodowisko pracy - halas Szczytowy poziom dzwieku C\nZakres (44 – 157) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 - punkt 10 i 11","categories":["environment"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"C-weighted peak sound pressure level","parameters_en":[{"name":"Range","range":"(44 – 157) dB"}],"search_en":"Workplace environment - noise C-weighted peak sound pressure level Direct measurement method Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - noise","methodology_zh":"C 计权峰值声级","parameters_zh":[{"name":"范围","range":"(44 – 157) dB"}],"search_zh":"工作场所环境 — 噪声 C 计权峰值声级 直接测量法 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a7f12da1995264369d8e473","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11 Srodowisko pracy - halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 - punkt 10 i 11","categories":["environment"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment - noise Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","test_object_en":"Workplace environment - noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a7f12da1995264369d8e474","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"substancje nieorganiczne"},{"name":"frakcja respirabilna"},{"name":"metale i ich związki, w tym"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"substancje organiczne"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje nieorganiczne\nfrakcja respirabilna\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje organiczne\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Ap1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002+Ap1:2004"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje nieorganiczne\nfrakcja respirabilna\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje organiczne\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Ap1:2004 Srodowisko pracy - powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje nieorganiczne\nfrakcja respirabilna\nmetale i ich zwiazki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje organiczne\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Ap1:2004","categories":["materials","environment"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"inorganic substances"},{"name":"respirable fraction"},{"name":"metals and their compounds, including"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"organic substances"}],"search_en":"Workplace environment - air Sampling for the assessment of occupational exposure to: Personal dosimetry method dust agents inhalable fraction respirable fraction inorganic substances respirable fraction metals and their compounds, including inhalable fraction respirable fraction organic substances PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Ap1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment - air","methodology_zh":"职业接触评估采样，针对：","parameters_zh":[{"name":"粉尘因素"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"无机物质"},{"name":"呼吸性组分"},{"name":"金属及其化合物，包括"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"有机物质"}],"search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 粉尘因素 可吸入组分 呼吸性组分 无机物质 呼吸性组分 金属及其化合物，包括 可吸入组分 呼吸性组分 有机物质 PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Ap1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a7f12da1995264369d8e475","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Ap1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002+Ap1:2004"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Ap1:2004 Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Ap1:2004","categories":["environment"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment - air Exposure index (calculated) PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Ap1:2004","test_object_en":"Workplace environment - air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Ap1:2004","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a7f12da1995264369d8e476","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna","parameters":[{"name":"pyły drewna"},{"name":"węgiel (kamienny, brunatny)"},{"name":"pyły niesklasyfikowane ze względu na toksyczność"},{"name":"pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Zakres","range":"(0,04 – 30,66) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\npyły drewna\nwęgiel (kamienny, brunatny)\npyły niesklasyfikowane ze względu na toksyczność\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nZakres (0,04 – 30,66) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05","norm_bases":["PN-Z-04507:2022-05"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\npyły drewna\nwęgiel (kamienny, brunatny)\npyły niesklasyfikowane ze względu na toksyczność\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nZakres (0,04 – 30,66) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\npyly drewna\nwegiel (kamienny, brunatny)\npyly niesklasyfikowane ze wzgledu na toksycznosc\npyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nZakres (0,04 – 30,66) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05","categories":["environment"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents – inhalable fraction","parameters_en":[{"name":"wood dusts"},{"name":"coal (hard, brown)"},{"name":"dusts not classified according to toxicity"},{"name":"organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Range","range":"(0,04 – 30,66) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents – inhalable fraction Gravimetric method wood dusts coal (hard, brown) dusts not classified according to toxicity organic dusts of animal and plant origin, excluding wood and flour dusts Range PN-Z-04507:2022-05","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"木粉尘"},{"name":"煤（烟煤、褐煤）"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"范围","range":"(0,04 – 30,66) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分 重量法 木粉尘 煤（烟煤、褐煤） 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 范围 PN-Z-04507:2022-05","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分"},{"_id":"6a7f12da1995264369d8e477","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna","parameters":[{"name":"węgiel (kamienny, brunatny)"},{"name":"pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Zakres","range":"(0,04 – 12,39) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\nwęgiel (kamienny, brunatny)\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nZakres (0,04 – 12,39) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05","norm_bases":["PN-Z-04508:2022-05"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\nwęgiel (kamienny, brunatny)\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nZakres (0,04 – 12,39) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\nwegiel (kamienny, brunatny)\npyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nZakres (0,04 – 12,39) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05","categories":["environment"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents – respirable fraction","parameters_en":[{"name":"coal (hard, brown)"},{"name":"organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Range","range":"(0,04 – 12,39) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents – respirable fraction Gravimetric method coal (hard, brown) organic dusts of animal and plant origin, excluding wood and flour dusts Range PN-Z-04508:2022-05","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"煤（烟煤、褐煤）"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"范围","range":"(0,04 – 12,39) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 呼吸性组分 重量法 煤（烟煤、褐煤） 动植物来源有机粉尘，木粉和面粉除外 范围 PN-Z-04508:2022-05","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分"},{"_id":"6a7f12da1995264369d8e478","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry","methodology":"Stężenie tlenków żelaza w przeliczeniu na Fe","parameters":[{"name":"Tlenek żelaza (III)"},{"name":"Tlenek żelaza (II)"},{"name":"Tetratlenek triżelaza"},{"name":"frakcja wdychalna","range":"(0,417 – 20,833) mg/m3"},{"name":"frakcja respirabilna","range":"(0,189 – 9,470) mg/m3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie tlenków żelaza w przeliczeniu na Fe\nZakres:\nTlenek żelaza (III)\nTlenek żelaza (II)\nTetratlenek triżelaza\nfrakcja wdychalna (0,417 – 20,833) mg/m3\nfrakcja respirabilna (0,189 – 9,470) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04469:2015-10","norm_bases":["PN-Z-04469:2015-10"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry Stężenie tlenków żelaza w przeliczeniu na Fe\nZakres:\nTlenek żelaza (III)\nTlenek żelaza (II)\nTetratlenek triżelaza\nfrakcja wdychalna (0,417 – 20,833) mg/m3\nfrakcja respirabilna (0,189 – 9,470) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04469:2015-10 Srodowisko pracy - powietrze - probki powietrza pobrane na filtry Stezenie tlenkow zelaza w przeliczeniu na Fe\nZakres:\nTlenek zelaza (III)\nTlenek zelaza (II)\nTetratlenek trizelaza\nfrakcja wdychalna (0,417 – 20,833) mg/m3\nfrakcja respirabilna (0,189 – 9,470) mg/m3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04469:2015-10","categories":["environment"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of iron oxides calculated as Fe","parameters_en":[{"name":"Iron(III) oxide"},{"name":"Iron(II) oxide"},{"name":"Triiron tetraoxide"},{"name":"inhalable fraction","range":"(0,417 – 20,833) mg/m3"},{"name":"respirable fraction","range":"(0,189 – 9,470) mg/m3"}],"search_en":"Workplace environment - air - air samples collected on filters Concentration of iron oxides calculated as Fe Flame atomic absorption spectrometry (FAAS) Iron(III) oxide Iron(II) oxide Triiron tetraoxide inhalable fraction respirable fraction PN-Z-04469:2015-10","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air - air samples collected on filters","parameters_zh":[{"name":"Tlenek żelaza (III)"},{"name":"Tlenek żelaza (II)"},{"name":"四氧化三铁"},{"name":"可吸入组分","range":"(0,417 – 20,833) mg/m3"},{"name":"呼吸性组分","range":"(0,189 – 9,470) mg/m3"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 铁氧化物浓度（以 Fe 计） 火焰原子吸收光谱法（FAAS） 四氧化三铁 可吸入组分 呼吸性组分 PN-Z-04469:2015-10","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","methodology_zh":"铁氧化物浓度（以 Fe 计）"},{"_id":"6a7f12da1995264369d8e479","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry","methodology":"Stężenie manganu i jego związków nieorganicznych w przeliczeniu na Mn","parameters":[{"name":"frakcja wdychalna","range":"(0,017 – 0,444) mg/m3"},{"name":"frakcja respirabilna","range":"(0,004 – 0,101) mg/m3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie manganu i jego związków nieorganicznych w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna (0,017 – 0,444) mg/m3\nfrakcja respirabilna (0,004 – 0,101) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04472:2015-10 | PN-Z-04472:2015-10/AP1:2015-12","norm_bases":["PN-Z-04472:2015-10","PN-Z-04472:2015-10/AP1:2015-12"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry Stężenie manganu i jego związków nieorganicznych w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna (0,017 – 0,444) mg/m3\nfrakcja respirabilna (0,004 – 0,101) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04472:2015-10 | PN-Z-04472:2015-10/AP1:2015-12 Srodowisko pracy - powietrze - probki powietrza pobrane na filtry Stezenie manganu i jego zwiazkow nieorganicznych w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna (0,017 – 0,444) mg/m3\nfrakcja respirabilna (0,004 – 0,101) mg/m3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04472:2015-10 | PN-Z-04472:2015-10/AP1:2015-12","categories":["environment"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of manganese and its inorganic compounds calculated as Mn","parameters_en":[{"name":"inhalable fraction","range":"(0,017 – 0,444) mg/m3"},{"name":"respirable fraction","range":"(0,004 – 0,101) mg/m3"}],"search_en":"Workplace environment - air - air samples collected on filters Concentration of manganese and its inorganic compounds calculated as Mn Flame atomic absorption spectrometry (FAAS) inhalable fraction respirable fraction PN-Z-04472:2015-10 | PN-Z-04472:2015-10/AP1:2015-12","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air - air samples collected on filters","parameters_zh":[{"name":"可吸入组分","range":"(0,017 – 0,444) mg/m3"},{"name":"呼吸性组分","range":"(0,004 – 0,101) mg/m3"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 锰及其无机化合物浓度（以 Mn 计） 火焰原子吸收光谱法（FAAS） 可吸入组分 呼吸性组分 PN-Z-04472:2015-10 | PN-Z-04472:2015-10/AP1:2015-12","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","methodology_zh":"锰及其无机化合物浓度（以 Mn 计）"},{"_id":"6a7f12da1995264369d8e47a","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry","methodology":"Stężenie ołowiu i jego związków nieorganicznych, z wyjątkiem arsenianu(V) ołowiu(II) oraz chromianu(VI) ołowiu(II) – w przeliczeniu na Pb","parameters":[{"name":"frakcja wdychalna","range":"(0,0035 – 0,1389) mg/m3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie ołowiu i jego związków nieorganicznych, z wyjątkiem arsenianu(V) ołowiu(II) oraz chromianu(VI) ołowiu(II) – w przeliczeniu na Pb\nfrakcja wdychalna (0,0035 – 0,1389) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04487:2017-10","norm_bases":["PN-Z-04487:2017-10"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry Stężenie ołowiu i jego związków nieorganicznych, z wyjątkiem arsenianu(V) ołowiu(II) oraz chromianu(VI) ołowiu(II) – w przeliczeniu na Pb\nfrakcja wdychalna (0,0035 – 0,1389) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04487:2017-10 Srodowisko pracy - powietrze - probki powietrza pobrane na filtry Stezenie olowiu i jego zwiazkow nieorganicznych, z wyjatkiem arsenianu(V) olowiu(II) oraz chromianu(VI) olowiu(II) – w przeliczeniu na Pb\nfrakcja wdychalna (0,0035 – 0,1389) mg/m3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04487:2017-10","categories":["environment"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"inhalable fraction","range":"(0,0035 – 0,1389) mg/m3"}],"search_en":"Workplace environment - air - air samples collected on filters Flame atomic absorption spectrometry (FAAS) inhalable fraction PN-Z-04487:2017-10","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air - air samples collected on filters","parameters_zh":[{"name":"可吸入组分","range":"(0,0035 – 0,1389) mg/m3"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 火焰原子吸收光谱法（FAAS） 可吸入组分 PN-Z-04487:2017-10","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品"},{"_id":"6a7f12da1995264369d8e47b","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość krystalicznej krzemionki (kwarc, krystobalit)","parameters":[{"name":"frakcja respirabilna","range":"(0,013 – 0,505) mg/m3"},{"name":"frakcja respirabilna","range":"(10 – 400) μg w próbce"}],"technique":"Metoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)","techniques":["Metoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)"],"computed":[],"activity":"Stężenie/zawartość krystalicznej krzemionki (kwarc, krystobalit)\nZakres:\nfrakcja respirabilna (0,013 – 0,505) mg/m3\nfrakcja respirabilna (10 – 400) μg w próbce\nMetoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry Stężenie/zawartość krystalicznej krzemionki (kwarc, krystobalit)\nZakres:\nfrakcja respirabilna (0,013 – 0,505) mg/m3\nfrakcja respirabilna (10 – 400) μg w próbce\nMetoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR) Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130 Srodowisko pracy - powietrze - probki powietrza pobrane na filtry Stezenie/zawartosc krystalicznej krzemionki (kwarc, krystobalit)\nZakres:\nfrakcja respirabilna (0,013 – 0,505) mg/m3\nfrakcja respirabilna (10 – 400) μg w probce\nMetoda spektrometrii w zakresie podczerwieni z transformacja Fouriera (FT-IR) Podstawy i Metody Oceny Srodowiska Pracy 2012, 4 (74), str. 117-130","categories":["environment"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Crystalline silica (quartz, cristobalite) concentration/content","parameters_en":[{"name":"respirable fraction","range":"(0,013 – 0,505) mg/m3"},{"name":"respirable fraction","range":"(10 – 400) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected on filters Crystalline silica (quartz, cristobalite) concentration/content Fourier transform infrared spectrometry (FT-IR) respirable fraction respirable fraction Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130","technique_en":"Fourier transform infrared spectrometry (FT-IR)","test_object_en":"Workplace environment - air - air samples collected on filters","parameters_zh":[{"name":"呼吸性组分","range":"(0,013 – 0,505) mg/m3"},{"name":"呼吸性组分","range":"(10 – 400) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 结晶二氧化硅（石英、方石英）的浓度/含量 傅里叶变换红外光谱法（FT-IR） 呼吸性组分 呼吸性组分 Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","methodology_zh":"结晶二氧化硅（石英、方石英）的浓度/含量","technique_zh":"傅里叶变换红外光谱法（FT-IR）"},{"_id":"6a7f12da1995264369d8e47c","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość związków organicznych","parameters":[{"name":"aceton","range":"(38,3 – 3833) mg/m3"},{"name":"aceton","range":"(0,03 – 3,45) mg w próbce"},{"name":"butan - 1-ol","range":"(4,5 – 450) mg/m3"},{"name":"butan - 1-ol","range":"(0,03 – 3,24) mg w próbce"},{"name":"2-butoksyetanol","range":"(8,5 – 425) mg/m3"},{"name":"2-butoksyetanol","range":"(0,06 – 3,06) mg w próbce"},{"name":"etanol","range":"(84,2 – 4208) mg/m3"},{"name":"etanol","range":"(0,02 – 0,95) mg w próbce"},{"name":"2-etoksyetanol","range":"(0,5 – 26) mg/m3"},{"name":"2-etoksyetanol","range":"(0,002 – 0,09) mg w próbce"},{"name":"ksylen (mieszanina izomerów 1,2; 1,3; 1,4)","range":"(4,3 – 433) mg/m3"},{"name":"ksylen (mieszanina izomerów 1,2; 1,3; 1,4)","range":"(0,03 – 3,12) mg w próbce"},{"name":"2-Metylopropan-1-ol","range":"(4,9 – 490) mg/m3"},{"name":"2-Metylopropan-1-ol","range":"(0,04 – 3,53) mg w próbce"},{"name":"octan n-butylu","range":"(19,6 – 1960) mg/m3"},{"name":"octan n-butylu","range":"(0,14 – 14,11) mg w próbce"},{"name":"octan 2-etoksyetylu","range":"(1,0 – 49) mg/m3"},{"name":"octan 2-etoksyetylu","range":"(0,01 – 0,35) mg w próbce"},{"name":"octan etylu","range":"(20,0 – 3007) mg/m3"},{"name":"octan etylu","range":"(0,14 – 21,65) mg w próbce"},{"name":"toluen","range":"(8,2 – 409) mg/m3"},{"name":"toluen","range":"(0,06 – 2,95) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrii mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrii mas (GC-MS)"],"computed":[],"activity":"Stężenie / zawartość związków organicznych\nZakres:\naceton (38,3 – 3833) mg/m3\naceton (0,03 – 3,45) mg w próbce\nbutan - 1-ol (4,5 – 450) mg/m3\nbutan - 1-ol (0,03 – 3,24) mg w próbce\n2-butoksyetanol (8,5 – 425) mg/m3\n2-butoksyetanol (0,06 – 3,06) mg w próbce\netanol (84,2 – 4208) mg/m3\netanol (0,02 – 0,95) mg w próbce\n2-etoksyetanol (0,5 – 26) mg/m3\n2-etoksyetanol (0,002 – 0,09) mg w próbce\nksylen (mieszanina izomerów 1,2; 1,3; 1,4) (4,3 – 433) mg/m3\nksylen (mieszanina izomerów 1,2; 1,3; 1,4) (0,03 – 3,12) mg w próbce\n2-Metylopropan-1-ol (4,9 – 490) mg/m3\n2-Metylopropan-1-ol (0,04 – 3,53) mg w próbce\noctan n-butylu (19,6 – 1960) mg/m3\noctan n-butylu (0,14 – 14,11) mg w próbce\noctan 2-etoksyetylu (1,0 – 49) mg/m3\noctan 2-etoksyetylu (0,01 – 0,35) mg w próbce\noctan etylu (20,0 – 3007) mg/m3\noctan etylu (0,14 – 21,65) mg w próbce\ntoluen (8,2 – 409) mg/m3\ntoluen (0,06 – 2,95) mg w próbce\nMetoda chromatografii gazowej z detekcją spektrometrii mas (GC-MS)","reference":"PN-Z-04023-02:1989","norm_bases":["PN-Z-04023-02:1989"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość związków organicznych\nZakres:\naceton (38,3 – 3833) mg/m3\naceton (0,03 – 3,45) mg w próbce\nbutan - 1-ol (4,5 – 450) mg/m3\nbutan - 1-ol (0,03 – 3,24) mg w próbce\n2-butoksyetanol (8,5 – 425) mg/m3\n2-butoksyetanol (0,06 – 3,06) mg w próbce\netanol (84,2 – 4208) mg/m3\netanol (0,02 – 0,95) mg w próbce\n2-etoksyetanol (0,5 – 26) mg/m3\n2-etoksyetanol (0,002 – 0,09) mg w próbce\nksylen (mieszanina izomerów 1,2; 1,3; 1,4) (4,3 – 433) mg/m3\nksylen (mieszanina izomerów 1,2; 1,3; 1,4) (0,03 – 3,12) mg w próbce\n2-Metylopropan-1-ol (4,9 – 490) mg/m3\n2-Metylopropan-1-ol (0,04 – 3,53) mg w próbce\noctan n-butylu (19,6 – 1960) mg/m3\noctan n-butylu (0,14 – 14,11) mg w próbce\noctan 2-etoksyetylu (1,0 – 49) mg/m3\noctan 2-etoksyetylu (0,01 – 0,35) mg w próbce\noctan etylu (20,0 – 3007) mg/m3\noctan etylu (0,14 – 21,65) mg w próbce\ntoluen (8,2 – 409) mg/m3\ntoluen (0,06 – 2,95) mg w próbce\nMetoda chromatografii gazowej z detekcją spektrometrii mas (GC-MS) PN-Z-04023-02:1989 Srodowisko pracy - powietrze - probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc zwiazkow organicznych\nZakres:\naceton (38,3 – 3833) mg/m3\naceton (0,03 – 3,45) mg w probce\nbutan - 1-ol (4,5 – 450) mg/m3\nbutan - 1-ol (0,03 – 3,24) mg w probce\n2-butoksyetanol (8,5 – 425) mg/m3\n2-butoksyetanol (0,06 – 3,06) mg w probce\netanol (84,2 – 4208) mg/m3\netanol (0,02 – 0,95) mg w probce\n2-etoksyetanol (0,5 – 26) mg/m3\n2-etoksyetanol (0,002 – 0,09) mg w probce\nksylen (mieszanina izomerow 1,2; 1,3; 1,4) (4,3 – 433) mg/m3\nksylen (mieszanina izomerow 1,2; 1,3; 1,4) (0,03 – 3,12) mg w probce\n2-Metylopropan-1-ol (4,9 – 490) mg/m3\n2-Metylopropan-1-ol (0,04 – 3,53) mg w probce\noctan n-butylu (19,6 – 1960) mg/m3\noctan n-butylu (0,14 – 14,11) mg w probce\noctan 2-etoksyetylu (1,0 – 49) mg/m3\noctan 2-etoksyetylu (0,01 – 0,35) mg w probce\noctan etylu (20,0 – 3007) mg/m3\noctan etylu (0,14 – 21,65) mg w probce\ntoluen (8,2 – 409) mg/m3\ntoluen (0,06 – 2,95) mg w probce\nMetoda chromatografii gazowej z detekcja spektrometrii mas (GC-MS) PN-Z-04023-02:1989","categories":["environment"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"acetone","range":"(38,3 – 3833) mg/m3"},{"name":"acetone","range":"(0,03 – 3,45) mg w próbce"},{"name":"butan - 1-ol","range":"(4,5 – 450) mg/m3"},{"name":"butan - 1-ol","range":"(0,03 – 3,24) mg w próbce"},{"name":"2-butoxyethanol","range":"(8,5 – 425) mg/m3"},{"name":"2-butoxyethanol","range":"(0,06 – 3,06) mg w próbce"},{"name":"ethanol","range":"(84,2 – 4208) mg/m3"},{"name":"ethanol","range":"(0,02 – 0,95) mg w próbce"},{"name":"2-ethoxyethanol","range":"(0,5 – 26) mg/m3"},{"name":"2-ethoxyethanol","range":"(0,002 – 0,09) mg w próbce"},{"name":"ksylen (mieszanina izomerów 1,2; 1,3; 1,4)","range":"(4,3 – 433) mg/m3"},{"name":"ksylen (mieszanina izomerów 1,2; 1,3; 1,4)","range":"(0,03 – 3,12) mg w próbce"},{"name":"2-Methylpropan-1-ol","range":"(4,9 – 490) mg/m3"},{"name":"2-Methylpropan-1-ol","range":"(0,04 – 3,53) mg w próbce"},{"name":"n-butyl acetate","range":"(19,6 – 1960) mg/m3"},{"name":"n-butyl acetate","range":"(0,14 – 14,11) mg w próbce"},{"name":"2-ethoxyethyl acetate","range":"(1,0 – 49) mg/m3"},{"name":"2-ethoxyethyl acetate","range":"(0,01 – 0,35) mg w próbce"},{"name":"ethyl acetate","range":"(20,0 – 3007) mg/m3"},{"name":"ethyl acetate","range":"(0,14 – 21,65) mg w próbce"},{"name":"toluene","range":"(8,2 – 409) mg/m3"},{"name":"toluene","range":"(0,06 – 2,95) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected into sorbent tubes Gas chromatography with mass spectrometry detection (GC-MS) acetone acetone 2-butoxyethanol 2-butoxyethanol ethanol ethanol 2-ethoxyethanol 2-ethoxyethanol 2-Methylpropan-1-ol 2-Methylpropan-1-ol n-butyl acetate n-butyl acetate 2-ethoxyethyl acetate 2-ethoxyethyl acetate ethyl acetate ethyl acetate toluene toluene PN-Z-04023-02:1989","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Workplace environment - air - air samples collected into sorbent tubes","parameters_zh":[{"name":"丙酮","range":"(38,3 – 3833) mg/m3"},{"name":"丙酮","range":"(0,03 – 3,45) mg w próbce"},{"name":"butan - 1-ol","range":"(4,5 – 450) mg/m3"},{"name":"butan - 1-ol","range":"(0,03 – 3,24) mg w próbce"},{"name":"2-丁氧基乙醇","range":"(8,5 – 425) mg/m3"},{"name":"2-丁氧基乙醇","range":"(0,06 – 3,06) mg w próbce"},{"name":"乙醇","range":"(84,2 – 4208) mg/m3"},{"name":"乙醇","range":"(0,02 – 0,95) mg w próbce"},{"name":"2-乙氧基乙醇","range":"(0,5 – 26) mg/m3"},{"name":"2-乙氧基乙醇","range":"(0,002 – 0,09) mg w próbce"},{"name":"ksylen (mieszanina izomerów 1,2; 1,3; 1,4)","range":"(4,3 – 433) mg/m3"},{"name":"ksylen (mieszanina izomerów 1,2; 1,3; 1,4)","range":"(0,03 – 3,12) mg w próbce"},{"name":"2-Metylopropan-1-ol","range":"(4,9 – 490) mg/m3"},{"name":"2-Metylopropan-1-ol","range":"(0,04 – 3,53) mg w próbce"},{"name":"乙酸正丁酯","range":"(19,6 – 1960) mg/m3"},{"name":"乙酸正丁酯","range":"(0,14 – 14,11) mg w próbce"},{"name":"乙二醇乙醚醋酸酯","range":"(1,0 – 49) mg/m3"},{"name":"乙二醇乙醚醋酸酯","range":"(0,01 – 0,35) mg w próbce"},{"name":"乙酸乙酯","range":"(20,0 – 3007) mg/m3"},{"name":"乙酸乙酯","range":"(0,14 – 21,65) mg w próbce"},{"name":"甲苯","range":"(8,2 – 409) mg/m3"},{"name":"甲苯","range":"(0,06 – 2,95) mg w próbce"}],"search_zh":"工作环境 － 空气 － 采集于吸附管中的空气样品 气相色谱-质谱检测法（GC-MS） 丙酮 丙酮 2-丁氧基乙醇 2-丁氧基乙醇 乙醇 乙醇 2-乙氧基乙醇 2-乙氧基乙醇 乙酸正丁酯 乙酸正丁酯 乙二醇乙醚醋酸酯 乙二醇乙醚醋酸酯 乙酸乙酯 乙酸乙酯 甲苯 甲苯 PN-Z-04023-02:1989","technique_zh":"气相色谱-质谱检测法（GC-MS）","test_object_zh":"工作环境 － 空气 － 采集于吸附管中的空气样品"},{"_id":"6a7f12da1995264369d8e47d","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość związków organicznych","parameters":[{"name":"benzen","range":"(0,05 – 3,54) mg/m3"},{"name":"benzen","range":"(0,001 – 0,070) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrii mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrii mas (GC-MS)"],"computed":[],"activity":"Stężenie / zawartość związków organicznych\nZakres:\nbenzen (0,05 – 3,54) mg/m3\nbenzen (0,001 – 0,070) mg w próbce\nMetoda chromatografii gazowej z detekcją spektrometrii mas (GC-MS)","reference":"PN-Z-04016:2005-10","norm_bases":["PN-Z-04016:2005-10"],"lab_section":"Zespół Laboratoryjny; Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość związków organicznych\nZakres:\nbenzen (0,05 – 3,54) mg/m3\nbenzen (0,001 – 0,070) mg w próbce\nMetoda chromatografii gazowej z detekcją spektrometrii mas (GC-MS) PN-Z-04016:2005-10 Srodowisko pracy - powietrze - probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc zwiazkow organicznych\nZakres:\nbenzen (0,05 – 3,54) mg/m3\nbenzen (0,001 – 0,070) mg w probce\nMetoda chromatografii gazowej z detekcja spektrometrii mas (GC-MS) PN-Z-04016:2005-10","categories":["environment"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"benzene","range":"(0,05 – 3,54) mg/m3"},{"name":"benzene","range":"(0,001 – 0,070) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected into sorbent tubes Gas chromatography with mass spectrometry detection (GC-MS) benzene benzene PN-Z-04016:2005-10","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Workplace environment - air - air samples collected into sorbent tubes","parameters_zh":[{"name":"苯","range":"(0,05 – 3,54) mg/m3"},{"name":"苯","range":"(0,001 – 0,070) mg w próbce"}],"search_zh":"工作环境 － 空气 － 采集于吸附管中的空气样品 气相色谱-质谱检测法（GC-MS） 苯 苯 PN-Z-04016:2005-10","technique_zh":"气相色谱-质谱检测法（GC-MS）","test_object_zh":"工作环境 － 空气 － 采集于吸附管中的空气样品"},{"_id":"6a7f12da1995264369d8e47e","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Kał / wymaz z kału","methodology":"Obecność pałeczek z rodzaju Salmonella, Shigella","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność pałeczek z rodzaju Salmonella, Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB-01-LM, wyd. 5 z dnia 10.05.2026 r. w oparciu o publikację M.Jagielski Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń i zarażeń przewodu pokarmowego oraz zatruć pokarmowych Wydanie I, 2010 r. Schemat White’a Kaufmanna–Le Minora wyd. 9 z 2007 r.","norm_bases":["PB-01-LM, wyd. 5 z dnia 10.05.2026 r. w oparciu o publikację M.Jagielski Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń i zarażeń przewodu pokarmowego oraz zatruć pokarmowych Wydanie I, 2010 r. Schemat White’a Kaufmanna–Le Minora wyd. 9 z 2007 r."],"lab_section":"Zespół Laboratoryjny; Laboratorium Mikrobiologiczne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał / wymaz z kału Obecność pałeczek z rodzaju Salmonella, Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-01-LM, wyd. 5 z dnia 10.05.2026 r. w oparciu o publikację M.Jagielski Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń i zarażeń przewodu pokarmowego oraz zatruć pokarmowych Wydanie I, 2010 r. Schemat White’a Kaufmanna–Le Minora wyd. 9 z 2007 r. Kal / wymaz z kalu Obecnosc paleczek z rodzaju Salmonella, Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-01-LM, wyd. 5 z dnia 10.05.2026 r. w oparciu o publikacje M.Jagielski Etiologia, obraz kliniczny i diagnostyka ostrych zakazen i zarazen przewodu pokarmowego oraz zatruc pokarmowych Wydanie I, 2010 r. Schemat White’a Kaufmanna–Le Minora wyd. 9 z 2007 r.","categories":["microbiology"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Culture method with biochemical and serological confirmation PB-01-LM, wyd. 5 z dnia 10.05.2026 r. w oparciu o publikację M.Jagielski Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń i zarażeń przewodu pokarmowego oraz zatruć pokarmowych Wydanie I, 2010 r. Schemat White’a Kaufmanna–Le Minora wyd. 9 z 2007 r.","technique_en":"Culture method with biochemical and serological confirmation","search_zh":"培养法结合生化与血清学确认 PB-01-LM, wyd. 5 z dnia 10.05.2026 r. w oparciu o publikację M.Jagielski Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń i zarażeń przewodu pokarmowego oraz zatruć pokarmowych Wydanie I, 2010 r. Schemat White’a Kaufmanna–Le Minora wyd. 9 z 2007 r.","technique_zh":"培养法结合生化与血清学确认"},{"_id":"6a7f12da1995264369d8e47f","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Biologiczny wskaźnik kontroli skuteczności sterylizacji Sporal A","methodology":"Obecność drobnoustrojów wskaźnikowych Geobacillus stearothermaphilus","parameters":[],"technique":"Metoda hodowlana","techniques":["Metoda hodowlana"],"computed":[],"activity":"Obecność drobnoustrojów wskaźnikowych Geobacillus stearothermaphilus\nMetoda hodowlana","reference":"PB-02-LM, wyd. 6 z dnia 01.02.2026 r. w oparciu o instrukcję producenta testów","norm_bases":["PB-02-LM, wyd. 6 z dnia 01.02.2026 r. w oparciu o instrukcję producenta testów"],"lab_section":"Zespół Laboratoryjny; Laboratorium Mikrobiologiczne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Biologiczny wskaźnik kontroli skuteczności sterylizacji Sporal A Obecność drobnoustrojów wskaźnikowych Geobacillus stearothermaphilus\nMetoda hodowlana PB-02-LM, wyd. 6 z dnia 01.02.2026 r. w oparciu o instrukcję producenta testów Biologiczny wskaznik kontroli skutecznosci sterylizacji Sporal A Obecnosc drobnoustrojow wskaznikowych Geobacillus stearothermaphilus\nMetoda hodowlana PB-02-LM, wyd. 6 z dnia 01.02.2026 r. w oparciu o instrukcje producenta testow","categories":["microbiology"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Culture method PB-02-LM, wyd. 6 z dnia 01.02.2026 r. w oparciu o instrukcję producenta testów","technique_en":"Culture method","search_zh":"培养法 PB-02-LM, wyd. 6 z dnia 01.02.2026 r. w oparciu o instrukcję producenta testów","technique_zh":"培养法"},{"_id":"6a7f12da1995264369d8e480","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Kał / Wymaz z odbytu","methodology":"Obecność pałeczek z rodzaju Salmonella, Shigella","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność pałeczek z rodzaju Salmonella, Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB-04-LM, wyd. 3 z dnia 10.05.2026 r. w oparciu o publikację M.Jagielski Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń i zarażeń przewodu pokarmowego oraz zatruć pokarmowych Wydanie I, 2010 r. Schemat White’a Kaufmanna–Le Minora wyd. 9 z 2007r.","norm_bases":["PB-04-LM, wyd. 3 z dnia 10.05.2026 r. w oparciu o publikację M.Jagielski Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń i zarażeń przewodu pokarmowego oraz zatruć pokarmowych Wydanie I, 2010 r. Schemat White’a Kaufmanna–Le Minora wyd. 9 z 2007r."],"lab_section":"Zespół Laboratoryjny; Laboratorium Mikrobiologiczne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał / Wymaz z odbytu Obecność pałeczek z rodzaju Salmonella, Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-04-LM, wyd. 3 z dnia 10.05.2026 r. w oparciu o publikację M.Jagielski Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń i zarażeń przewodu pokarmowego oraz zatruć pokarmowych Wydanie I, 2010 r. Schemat White’a Kaufmanna–Le Minora wyd. 9 z 2007r. Kal / Wymaz z odbytu Obecnosc paleczek z rodzaju Salmonella, Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-04-LM, wyd. 3 z dnia 10.05.2026 r. w oparciu o publikacje M.Jagielski Etiologia, obraz kliniczny i diagnostyka ostrych zakazen i zarazen przewodu pokarmowego oraz zatruc pokarmowych Wydanie I, 2010 r. Schemat White’a Kaufmanna–Le Minora wyd. 9 z 2007r.","categories":["microbiology"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Culture method with biochemical and serological confirmation PB-04-LM, wyd. 3 z dnia 10.05.2026 r. w oparciu o publikację M.Jagielski Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń i zarażeń przewodu pokarmowego oraz zatruć pokarmowych Wydanie I, 2010 r. Schemat White’a Kaufmanna–Le Minora wyd. 9 z 2007r.","technique_en":"Culture method with biochemical and serological confirmation","search_zh":"培养法结合生化与血清学确认 PB-04-LM, wyd. 3 z dnia 10.05.2026 r. w oparciu o publikację M.Jagielski Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń i zarażeń przewodu pokarmowego oraz zatruć pokarmowych Wydanie I, 2010 r. Schemat White’a Kaufmanna–Le Minora wyd. 9 z 2007r.","technique_zh":"培养法结合生化与血清学确认"},{"_id":"6a7f12da1995264369d8e481","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Wymaz z kału, odbytu / kał","methodology":"Wykrywanie kwasów nukleinowych specyficznych dla Salmonella sp., Shigella sp./enteroinwazyjne szczepy E. coli (EIEC), Yersinia enterocolitica, Campylobacter (jejuni, coli i upsaliensis)","parameters":[],"technique":"Metoda nested multiplex PCR","techniques":["Metoda nested multiplex PCR"],"computed":[],"activity":"Wykrywanie kwasów nukleinowych specyficznych dla Salmonella sp., Shigella sp./enteroinwazyjne szczepy E. coli (EIEC), Yersinia enterocolitica, Campylobacter (jejuni, coli i upsaliensis)\nMetoda nested multiplex PCR","reference":"Instrukcja producenta testu FilmArray®Gastrointestrial (GI) Panel z 04.06.2017 r.","norm_bases":["Instrukcja producenta testu FilmArray®Gastrointestrial (GI) Panel z 04.06.2017 r."],"lab_section":"Zespół Laboratoryjny; Laboratorium Mikrobiologiczne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wymaz z kału, odbytu / kał Wykrywanie kwasów nukleinowych specyficznych dla Salmonella sp., Shigella sp./enteroinwazyjne szczepy E. coli (EIEC), Yersinia enterocolitica, Campylobacter (jejuni, coli i upsaliensis)\nMetoda nested multiplex PCR Instrukcja producenta testu FilmArray®Gastrointestrial (GI) Panel z 04.06.2017 r. Wymaz z kalu, odbytu / kal Wykrywanie kwasow nukleinowych specyficznych dla Salmonella sp., Shigella sp./enteroinwazyjne szczepy E. coli (EIEC), Yersinia enterocolitica, Campylobacter (jejuni, coli i upsaliensis)\nMetoda nested multiplex PCR Instrukcja producenta testu FilmArray®Gastrointestrial (GI) Panel z 04.06.2017 r.","categories":["microbiology"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a7f12da1995264369d8e482","lab_id":"69ad52a3de79e566650fb584","country":"PL","accr_number":"AB 1087","accr_body":"PCA","test_object":"Dawkomierze w polu promieniowania jonizującego","methodology":"Indywidualny równoważnik dawki Hp(10) promieniowania fotonowego","parameters":[{"name":"Zakres","range":"(0,05 – 1500) mSv"}],"technique":"Metoda dozymetrii termoluminescencyjnej (TLD)","techniques":["Metoda dozymetrii termoluminescencyjnej (TLD)"],"computed":[],"activity":"Indywidualny równoważnik dawki Hp(10) promieniowania fotonowego\nZakres (0,05 – 1500) mSv\nMetoda dozymetrii termoluminescencyjnej (TLD)","reference":"PB-03-LHR z dnia 01.02.2022","norm_bases":["PB-03-LHR z dnia 01.02.2022"],"lab_section":"Zespół Laboratoryjny; Laboratorium Higieny Radiacyjnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Dawkomierze w polu promieniowania jonizującego Indywidualny równoważnik dawki Hp(10) promieniowania fotonowego\nZakres (0,05 – 1500) mSv\nMetoda dozymetrii termoluminescencyjnej (TLD) PB-03-LHR z dnia 01.02.2022 Dawkomierze w polu promieniowania jonizujacego Indywidualny rownowaznik dawki Hp(10) promieniowania fotonowego\nZakres (0,05 – 1500) mSv\nMetoda dozymetrii termoluminescencyjnej (TLD) PB-03-LHR z dnia 01.02.2022","categories":["other"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Personal dose equivalent Hp(10) of photon radiation","parameters_en":[{"name":"Range","range":"(0,05 – 1500) mSv"}],"search_en":"Dosimeters in an ionising radiation field Personal dose equivalent Hp(10) of photon radiation Thermoluminescence dosimetry method (TLD) Range PB-03-LHR z dnia 01.02.2022","technique_en":"Thermoluminescence dosimetry method (TLD)","test_object_en":"Dosimeters in an ionising radiation field","parameters_zh":[{"name":"范围","range":"(0,05 – 1500) mSv"}],"search_zh":"电离辐射场中的剂量计 热释光剂量测定法（TLD） 范围 PB-03-LHR z dnia 01.02.2022","test_object_zh":"电离辐射场中的剂量计","technique_zh":"热释光剂量测定法（TLD）"}],"has_pdf":true}