{"lab":{"_id":"69ad52a3de79e566650fb580","accr_number":"AB 1084","country":"PL","accr_body":"PCA","address":"LABORATORIUM, Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","categories":["water","microbiology","food","environment"],"city":"Ostrzeszów","imported_at":"2026-03-08T10:42:43.265Z","methods_count":73,"name":"SPÓŁKA WODNA „STRZEGOWA”","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1084.pdf"],"scope_summary":"","search_text":"spółka wodna „strzegowa” laboratorium, rojów, ul. krotoszyńska 4, 63-500 ostrzeszów environment microbiology food other pharma water automotive electronics","status":"active","updated_at":"2026-03-08T14:50:15.816Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T07:56:59.609Z","parse_date":"2026-08-13T07:56:59.609Z","parse_source":"agent-claude-code","email_confidence":"high","email_mx":true,"email_source":"https://www.labostrzeszow.pl/asp/kontakt,14,,1","fields_of_testing":[{"codes":"C/29/P; C/30/P; C/32/P","pl":"Badania chemiczne i pobieranie próbek wody do spożycia przez ludzi, ścieków, osadów","en":"Chemical tests and sampling of drinking water, sewage, sediments"},{"codes":"C/28/P","pl":"Badania chemiczne i pobieranie próbek wody","en":"Chemical tests and sampling of water"},{"codes":"K/28/P; K/29/P; K/57/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi, obiektów z obszaru produkcji żywności","en":"Microbiological tests and sampling of water, drinking water, objects from food production area"},{"codes":"K/42; K/22","pl":"Badania mikrobiologiczne kosmetyków, żywności","en":"Microbiological tests of cosmetics, food"},{"codes":"N/29/P; N/30/P; N/31/P; N/32/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody do spożycia przez ludzi, ścieków, gleby, osadów","en":"Tests of physical properties and sampling of drinking water, sewage, soil, sediments,"},{"codes":"N/28/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody","en":"Tests of physical properties and sampling of water"}],"issue":{"no":"19","date":"08.07.2026"},"map_coord":[51.432595,17.895784],"map_geo":"nominatim-street","lab_locations":[{"name":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/59528230205e68328a6209aa9875746f/AB%201084.pdf","has_en":true,"category_counts":{"water":52,"microbiology":21,"food":17,"environment":10,"other":1},"category_scores":{"water":26.77,"microbiology":4.37,"food":2.86,"environment":0.99,"other":0.01},"has_zh":true,"lab_locations_zh":[{"name":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7d78cb0636ba417e41a270","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji, żywności i obrotu żywnością: - wymaz - odcisk","methodology":"Pobieranie próbek z powierzchni do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek z powierzchni do badań mikrobiologicznych","reference":"PN-EN ISO 18593:2018-08","norm_bases":["PN-EN ISO 18593:2018-08"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji, żywności i obrotu żywnością: - wymaz - odcisk Pobieranie próbek z powierzchni do badań mikrobiologicznych PN-EN ISO 18593:2018-08 Probki srodowiskowe z obszarow produkcji, zywnosci i obrotu zywnoscia: - wymaz - odcisk Pobieranie probek z powierzchni do badan mikrobiologicznych PN-EN ISO 18593:2018-08","categories":["food","environment","microbiology"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Surface sampling for microbiological testing","search_en":"Environmental samples from production, food and food distribution areas: - swab - imprint Surface sampling for microbiological testing Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 18593:2018-08","test_object_en":"Environmental samples from production, food and food distribution areas: - swab - imprint","methodology_zh":"微生物检测用表面样品采集","search_zh":"微生物检测用表面样品采集 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 18593:2018-08","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów"},{"_id":"6a7d78cb0636ba417e41a271","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością, pomieszczeń użyteczności publicznej: - odcisk","methodology":"Liczba drobnoustrojów w 30°C","parameters":[],"technique":"Metoda płytek kontaktowych","techniques":["Metoda płytek kontaktowych"],"computed":[],"activity":"Liczba drobnoustrojów w 30°C\nMetoda płytek kontaktowych","reference":"PN-EN ISO 4833-2:2013-12 | PN-EN ISO 4833-2:2013-12/AC:2014-04 | PN-EN ISO 4833-2:2013-12/A1:2022-06","norm_bases":["PN-EN ISO 4833-2:2013-12","PN-EN ISO 4833-2:2013-12/AC:2014-04","PN-EN ISO 4833-2:2013-12/A1:2022-06"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością, pomieszczeń użyteczności publicznej: - odcisk Liczba drobnoustrojów w 30°C\nMetoda płytek kontaktowych PN-EN ISO 4833-2:2013-12 | PN-EN ISO 4833-2:2013-12/AC:2014-04 | PN-EN ISO 4833-2:2013-12/A1:2022-06 Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia, pomieszczen uzytecznosci publicznej: - odcisk Liczba drobnoustrojow w 30°C\nMetoda plytek kontaktowych PN-EN ISO 4833-2:2013-12 | PN-EN ISO 4833-2:2013-12/AC:2014-04 | PN-EN ISO 4833-2:2013-12/A1:2022-06","categories":["food","environment","microbiology"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Microorganism count at 30°C","search_en":"Environmental samples from food production and food trade areas, public buildings: - imprint Microorganism count at 30°C Contact plate method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 4833-2:2013-12 | PN-EN ISO 4833-2:2013-12/AC:2014-04 | PN-EN ISO 4833-2:2013-12/A1:2022-06","technique_en":"Contact plate method","test_object_en":"Environmental samples from food production and food trade areas, public buildings: - imprint","search_zh":"30°C 微生物数 接触平皿法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 4833-2:2013-12 | PN-EN ISO 4833-2:2013-12/AC:2014-04 | PN-EN ISO 4833-2:2013-12/A1:2022-06","technique_zh":"接触平皿法","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_zh":"30°C 微生物数"},{"_id":"6a7d78cb0636ba417e41a272","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością, pomieszczeń użyteczności publicznej: - odcisk","methodology":"Liczba Enterobacteriaceae","parameters":[],"technique":"Metoda płytek kontaktowych","techniques":["Metoda płytek kontaktowych"],"computed":[],"activity":"Liczba Enterobacteriaceae\nMetoda płytek kontaktowych","reference":"PN-EN ISO 21528-2:2017-08","norm_bases":["PN-EN ISO 21528-2:2017-08"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością, pomieszczeń użyteczności publicznej: - odcisk Liczba Enterobacteriaceae\nMetoda płytek kontaktowych PN-EN ISO 21528-2:2017-08 Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia, pomieszczen uzytecznosci publicznej: - odcisk Liczba Enterobacteriaceae\nMetoda plytek kontaktowych PN-EN ISO 21528-2:2017-08","categories":["food","environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Enterobacteriaceae count","search_en":"Environmental samples from food production and food trade areas, public buildings: - imprint Enterobacteriaceae count Contact plate method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 21528-2:2017-08","technique_en":"Contact plate method","test_object_en":"Environmental samples from food production and food trade areas, public buildings: - imprint","methodology_zh":"肠杆菌科（Enterobacteriaceae）计数","search_zh":"肠杆菌科（Enterobacteriaceae）计数 接触平皿法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 21528-2:2017-08","technique_zh":"接触平皿法","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów"},{"_id":"6a7d78cb0636ba417e41a273","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością, pomieszczeń użyteczności publicznej: - wymaz","methodology":"Liczba drobnoustrojów w 30°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów w 30°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 4833-1:2013-12 | PN-EN ISO 4833-1:2013-12/A1:2022-06","norm_bases":["PN-EN ISO 4833-1:2013-12","PN-EN ISO 4833-1:2013-12/A1:2022-06"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością, pomieszczeń użyteczności publicznej: - wymaz Liczba drobnoustrojów w 30°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 4833-1:2013-12 | PN-EN ISO 4833-1:2013-12/A1:2022-06 Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia, pomieszczen uzytecznosci publicznej: - wymaz Liczba drobnoustrojow w 30°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 4833-1:2013-12 | PN-EN ISO 4833-1:2013-12/A1:2022-06","categories":["food","environment","microbiology"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Microorganism count at 30°C","search_en":"Environmental samples from food production and food trade areas, public buildings: - swab Microorganism count at 30°C Plate method (pour plate) Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 4833-1:2013-12 | PN-EN ISO 4833-1:2013-12/A1:2022-06","technique_en":"Plate method (pour plate)","test_object_en":"Environmental samples from food production and food trade areas, public buildings: - swab","search_zh":"来自食品生产与流通场所、公共场所房间的环境样品：－ 涂抹样 30°C 微生物数 平板法（倾注培养） 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 4833-1:2013-12 | PN-EN ISO 4833-1:2013-12/A1:2022-06","technique_zh":"平板法（倾注培养）","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_zh":"30°C 微生物数","test_object_zh":"来自食品生产与流通场所、公共场所房间的环境样品：－ 涂抹样"},{"_id":"6a7d78cb0636ba417e41a274","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością, pomieszczeń użyteczności publicznej: - wymaz","methodology":"Liczba Enterobacteriaceae","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba Enterobacteriaceae\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 21528-2:2017-08","norm_bases":["PN-EN ISO 21528-2:2017-08"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością, pomieszczeń użyteczności publicznej: - wymaz Liczba Enterobacteriaceae\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 21528-2:2017-08 Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia, pomieszczen uzytecznosci publicznej: - wymaz Liczba Enterobacteriaceae\nMetoda plytkowa (posiew wglebny) PN-EN ISO 21528-2:2017-08","categories":["food","environment"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Enterobacteriaceae count","search_en":"Environmental samples from food production and food trade areas, public buildings: - swab Enterobacteriaceae count Plate method (pour plate) Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 21528-2:2017-08","technique_en":"Plate method (pour plate)","test_object_en":"Environmental samples from food production and food trade areas, public buildings: - swab","methodology_zh":"肠杆菌科（Enterobacteriaceae）计数","search_zh":"来自食品生产与流通场所、公共场所房间的环境样品：－ 涂抹样 肠杆菌科（Enterobacteriaceae）计数 平板法（倾注培养） 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 21528-2:2017-08","technique_zh":"平板法（倾注培养）","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","test_object_zh":"来自食品生产与流通场所、公共场所房间的环境样品：－ 涂抹样"},{"_id":"6a7d78cb0636ba417e41a275","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością, pomieszczeń użyteczności publicznej: - wymaz","methodology":"Obecność Listeria monocytogenes","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 11290-1:2017-07","norm_bases":["PN-EN ISO 11290-1:2017-07"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością, pomieszczeń użyteczności publicznej: - wymaz Obecność Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290-1:2017-07 Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia, pomieszczen uzytecznosci publicznej: - wymaz Obecnosc Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290-1:2017-07","categories":["food","environment","microbiology"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Presence of Listeria monocytogenes","search_en":"Environmental samples from food production and food trade areas, public buildings: - swab Presence of Listeria monocytogenes Culture method with biochemical confirmation Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 11290-1:2017-07","technique_en":"Culture method with biochemical confirmation","test_object_en":"Environmental samples from food production and food trade areas, public buildings: - swab","search_zh":"来自食品生产与流通场所、公共场所房间的环境样品：－ 涂抹样 单核细胞增生李斯特氏菌的检出 培养法结合生化确认 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 11290-1:2017-07","technique_zh":"培养法结合生化确认","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_zh":"单核细胞增生李斯特氏菌的检出","test_object_zh":"来自食品生产与流通场所、公共场所房间的环境样品：－ 涂抹样"},{"_id":"6a7d78cb0636ba417e41a276","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością, pomieszczeń użyteczności publicznej: - wymaz","methodology":"Obecność Salmonella spp.","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/ A1:2020-09","norm_bases":["PN-EN ISO 6579-1:2017-04","PN-EN ISO 6579-1:2017-04/ A1:2020-09"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością, pomieszczeń użyteczności publicznej: - wymaz Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/ A1:2020-09 Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia, pomieszczen uzytecznosci publicznej: - wymaz Obecnosc Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/ A1:2020-09","categories":["microbiology","food","environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Presence of Salmonella spp.","search_en":"Environmental samples from food production and food trade areas, public buildings: - swab Presence of Salmonella spp. Culture method with biochemical and serological confirmation Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/ A1:2020-09","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Environmental samples from food production and food trade areas, public buildings: - swab","methodology_zh":"沙门氏菌属（Salmonella spp.）的检出","search_zh":"来自食品生产与流通场所、公共场所房间的环境样品：－ 涂抹样 沙门氏菌属（Salmonella spp.）的检出 培养法结合生化与血清学确认 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/ A1:2020-09","technique_zh":"培养法结合生化与血清学确认","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","test_object_zh":"来自食品生产与流通场所、公共场所房间的环境样品：－ 涂抹样"},{"_id":"6a7d78cb0636ba417e41a277","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością, pomieszczeń użyteczności publicznej: - wymaz","methodology":"Obecność bakterii z grupy coli","parameters":[],"technique":"Metoda hodowlana","techniques":["Metoda hodowlana"],"computed":[],"activity":"Obecność bakterii z grupy coli\nMetoda hodowlana","reference":"PN-ISO 4831:2007","norm_bases":["PN-ISO 4831:2007"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością, pomieszczeń użyteczności publicznej: - wymaz Obecność bakterii z grupy coli\nMetoda hodowlana PN-ISO 4831:2007 Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia, pomieszczen uzytecznosci publicznej: - wymaz Obecnosc bakterii z grupy coli\nMetoda hodowlana PN-ISO 4831:2007","categories":["food","environment","microbiology"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Presence of coliform bacteria","search_en":"Environmental samples from food production and food trade areas, public buildings: - swab Presence of coliform bacteria Culture method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-ISO 4831:2007","technique_en":"Culture method","test_object_en":"Environmental samples from food production and food trade areas, public buildings: - swab","search_zh":"来自食品生产与流通场所、公共场所房间的环境样品：－ 涂抹样 大肠菌群的检出 培养法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-ISO 4831:2007","technique_zh":"培养法","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_zh":"大肠菌群的检出","test_object_zh":"来自食品生产与流通场所、公共场所房间的环境样品：－ 涂抹样"},{"_id":"6a7d78cb0636ba417e41a278","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Tusze zwierząt rzeźnych: - wymaz, Tusze drobiowe: - wycinki","methodology":"Obecność Salmonella spp.","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym.","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym."],"computed":[],"activity":"Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym.","reference":"PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020-09","norm_bases":["PN-EN ISO 6579-1:2017-04","PN-EN ISO 6579-1:2017-04/A1:2020-09"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Tusze zwierząt rzeźnych: - wymaz, Tusze drobiowe: - wycinki Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym. PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020-09 Tusze zwierzat rzeznych: - wymaz, Tusze drobiowe: - wycinki Obecnosc Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym. PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020-09","categories":["microbiology"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Presence of Salmonella spp.","search_en":"Carcasses of slaughter animals: - swab, Poultry carcasses: - excised samples Presence of Salmonella spp. Culture method with biochemical and serological confirmation. Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020-09","technique_en":"Culture method with biochemical and serological confirmation.","test_object_en":"Carcasses of slaughter animals: - swab, Poultry carcasses: - excised samples","methodology_zh":"沙门氏菌属（Salmonella spp.）的检出","search_zh":"沙门氏菌属（Salmonella spp.）的检出 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020-09","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów"},{"_id":"6a7d78cb0636ba417e41a279","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Tusze zwierząt rzeźnych: - wymaz - wycinki","methodology":"Liczba Enterobacteriaceae","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba Enterobacteriaceae\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 21528-2:2017-08","norm_bases":["PN-EN ISO 21528-2:2017-08"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Tusze zwierząt rzeźnych: - wymaz - wycinki Liczba Enterobacteriaceae\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 21528-2:2017-08 Tusze zwierzat rzeznych: - wymaz - wycinki Liczba Enterobacteriaceae\nMetoda plytkowa (posiew wglebny) PN-EN ISO 21528-2:2017-08","categories":["other"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Enterobacteriaceae count","search_en":"Slaughter animal carcasses: - swab - excisions Enterobacteriaceae count Plate method (pour plate) Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 21528-2:2017-08","technique_en":"Plate method (pour plate)","test_object_en":"Slaughter animal carcasses: - swab - excisions","methodology_zh":"肠杆菌科（Enterobacteriaceae）计数","search_zh":"屠宰动物胴体：－ 涂抹样 － 切片样 肠杆菌科（Enterobacteriaceae）计数 平板法（倾注培养） 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 21528-2:2017-08","technique_zh":"平板法（倾注培养）","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","test_object_zh":"屠宰动物胴体：－ 涂抹样 － 切片样"},{"_id":"6a7d78cb0636ba417e41a27a","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Tusze zwierząt rzeźnych: - wymaz - wycinki","methodology":"Liczba drobnoustrojów w 30°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów w 30°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 4833-1:2013-12 | PN-EN ISO 4833-1:2013-12/A1:2022-06","norm_bases":["PN-EN ISO 4833-1:2013-12","PN-EN ISO 4833-1:2013-12/A1:2022-06"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Tusze zwierząt rzeźnych: - wymaz - wycinki Liczba drobnoustrojów w 30°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 4833-1:2013-12 | PN-EN ISO 4833-1:2013-12/A1:2022-06 Tusze zwierzat rzeznych: - wymaz - wycinki Liczba drobnoustrojow w 30°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 4833-1:2013-12 | PN-EN ISO 4833-1:2013-12/A1:2022-06","categories":["microbiology"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Microorganism count at 30°C","search_en":"Slaughter animal carcasses: - swab - excisions Microorganism count at 30°C Plate method (pour plate) Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 4833-1:2013-12 | PN-EN ISO 4833-1:2013-12/A1:2022-06","technique_en":"Plate method (pour plate)","test_object_en":"Slaughter animal carcasses: - swab - excisions","search_zh":"屠宰动物胴体：－ 涂抹样 － 切片样 30°C 微生物数 平板法（倾注培养） 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 4833-1:2013-12 | PN-EN ISO 4833-1:2013-12/A1:2022-06","technique_zh":"平板法（倾注培养）","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_zh":"30°C 微生物数","test_object_zh":"屠宰动物胴体：－ 涂抹样 － 切片样"},{"_id":"6a7d78cb0636ba417e41a27b","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Mięso i produkty mięsne, Owoce, warzywa i przetwory, Mleko i produkty mleczne, Wyroby garmażeryjne, Jaja i produkty jajeczne, Wyroby cukiernicze i ciastkarskie, słodycze","methodology":"Obecność Salmonella spp.","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020-09","norm_bases":["PN-EN ISO 6579-1:2017-04","PN-EN ISO 6579-1:2017-04/A1:2020-09"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i produkty mięsne, Owoce, warzywa i przetwory, Mleko i produkty mleczne, Wyroby garmażeryjne, Jaja i produkty jajeczne, Wyroby cukiernicze i ciastkarskie, słodycze Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020-09 Mieso i produkty miesne, Owoce, warzywa i przetwory, Mleko i produkty mleczne, Wyroby garmazeryjne, Jaja i produkty jajeczne, Wyroby cukiernicze i ciastkarskie, slodycze Obecnosc Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020-09","categories":["food","microbiology"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Presence of Salmonella spp.","search_en":"Meat and meat products, Fruit, vegetables and their products, Milk and dairy products, Delicatessen products, Eggs and egg products, Confectionery and pastry products, sweets Presence of Salmonella spp. Culture method with biochemical and serological confirmation Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020-09","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Meat and meat products, Fruit, vegetables and their products, Milk and dairy products, Delicatessen products, Eggs and egg products, Confectionery and pastry products, sweets","methodology_zh":"沙门氏菌属（Salmonella spp.）的检出","search_zh":"沙门氏菌属（Salmonella spp.）的检出 培养法结合生化与血清学确认 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020-09","technique_zh":"培养法结合生化与血清学确认","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów"},{"_id":"6a7d78cb0636ba417e41a27c","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Mięso i produkty mięsne, Mleko i produkty mleczne, Napoje, Wyroby garmażeryjne","methodology":"Liczba drobnoustrojów w 30°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów w 30°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 4833-1:2013-12 | PN-EN ISO 4833-1:2013-12/A1:2022-06","norm_bases":["PN-EN ISO 4833-1:2013-12","PN-EN ISO 4833-1:2013-12/A1:2022-06"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i produkty mięsne, Mleko i produkty mleczne, Napoje, Wyroby garmażeryjne Liczba drobnoustrojów w 30°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 4833-1:2013-12 | PN-EN ISO 4833-1:2013-12/A1:2022-06 Mieso i produkty miesne, Mleko i produkty mleczne, Napoje, Wyroby garmazeryjne Liczba drobnoustrojow w 30°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 4833-1:2013-12 | PN-EN ISO 4833-1:2013-12/A1:2022-06","categories":["food","microbiology"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Microorganism count at 30°C","search_en":"Meat and meat products, Milk and dairy products, Beverages, Delicatessen products Microorganism count at 30°C Plate method (pour plate) Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 4833-1:2013-12 | PN-EN ISO 4833-1:2013-12/A1:2022-06","technique_en":"Plate method (pour plate)","test_object_en":"Meat and meat products, Milk and dairy products, Beverages, Delicatessen products","search_zh":"30°C 微生物数 平板法（倾注培养） 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 4833-1:2013-12 | PN-EN ISO 4833-1:2013-12/A1:2022-06","technique_zh":"平板法（倾注培养）","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_zh":"30°C 微生物数"},{"_id":"6a7d78cb0636ba417e41a27d","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Mięso i produkty mięsne, Owoce, warzywa i przetwory, Zboża i przetwory zbożowe, Wyroby garmażeryjne","methodology":"Liczba drobnoustrojów w 30°C","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba drobnoustrojów w 30°C\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 4833-2:2013-12 | PN-EN ISO 4833-2:2013-12/AC:2014-04 | PN-EN ISO 4833-2:2013-12/A1:2022-06","norm_bases":["PN-EN ISO 4833-2:2013-12","PN-EN ISO 4833-2:2013-12/AC:2014-04","PN-EN ISO 4833-2:2013-12/A1:2022-06"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i produkty mięsne, Owoce, warzywa i przetwory, Zboża i przetwory zbożowe, Wyroby garmażeryjne Liczba drobnoustrojów w 30°C\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 4833-2:2013-12 | PN-EN ISO 4833-2:2013-12/AC:2014-04 | PN-EN ISO 4833-2:2013-12/A1:2022-06 Mieso i produkty miesne, Owoce, warzywa i przetwory, Zboza i przetwory zbozowe, Wyroby garmazeryjne Liczba drobnoustrojow w 30°C\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 4833-2:2013-12 | PN-EN ISO 4833-2:2013-12/AC:2014-04 | PN-EN ISO 4833-2:2013-12/A1:2022-06","categories":["food","microbiology"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Microorganism count at 30°C","search_en":"Meat and meat products, Fruit, vegetables and their products, Cereals and cereal products, Delicatessen products Microorganism count at 30°C Plate method (spread plate) Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 4833-2:2013-12 | PN-EN ISO 4833-2:2013-12/AC:2014-04 | PN-EN ISO 4833-2:2013-12/A1:2022-06","technique_en":"Plate method (spread plate)","test_object_en":"Meat and meat products, Fruit, vegetables and their products, Cereals and cereal products, Delicatessen products","search_zh":"30°C 微生物数 平板法（表面涂布） 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 4833-2:2013-12 | PN-EN ISO 4833-2:2013-12/AC:2014-04 | PN-EN ISO 4833-2:2013-12/A1:2022-06","technique_zh":"平板法（表面涂布）","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_zh":"30°C 微生物数"},{"_id":"6a7d78cb0636ba417e41a27e","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Mięso i produkty mięsne, Owoce, warzywa i przetwory, Mleko i produkty mleczne, Wyroby garmażeryjne, Ryby i przetwory rybne, Wyroby cukiernicze i ciastkarskie, słodycze","methodology":"Obecność Listeria monocytogenes","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 11290-1:2017-07","norm_bases":["PN-EN ISO 11290-1:2017-07"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i produkty mięsne, Owoce, warzywa i przetwory, Mleko i produkty mleczne, Wyroby garmażeryjne, Ryby i przetwory rybne, Wyroby cukiernicze i ciastkarskie, słodycze Obecność Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290-1:2017-07 Mieso i produkty miesne, Owoce, warzywa i przetwory, Mleko i produkty mleczne, Wyroby garmazeryjne, Ryby i przetwory rybne, Wyroby cukiernicze i ciastkarskie, slodycze Obecnosc Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290-1:2017-07","categories":["food","microbiology"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Presence of Listeria monocytogenes","search_en":"Meat and meat products, Fruit, vegetables and their preserves, Milk and milk products, Delicatessen products, Fish and fish products, Confectionery and bakery products, sweets Presence of Listeria monocytogenes Culture method with biochemical confirmation Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 11290-1:2017-07","technique_en":"Culture method with biochemical confirmation","test_object_en":"Meat and meat products, Fruit, vegetables and their preserves, Milk and milk products, Delicatessen products, Fish and fish products, Confectionery and bakery products, sweets","search_zh":"单核细胞增生李斯特氏菌的检出 培养法结合生化确认 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 11290-1:2017-07","technique_zh":"培养法结合生化确认","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_zh":"单核细胞增生李斯特氏菌的检出"},{"_id":"6a7d78cb0636ba417e41a27f","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Mięso i produkty mięsne, Owoce, warzywa i przetwory, Mleko i produkty mleczne, Wyroby garmażeryjne, Ryby i przetwory rybne, Wyroby cukiernicze i ciastkarskie, słodycze","methodology":"Liczba Listeria monocytogenes","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba Listeria monocytogenes\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 11290-2:2017-07","norm_bases":["PN-EN ISO 11290-2:2017-07"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i produkty mięsne, Owoce, warzywa i przetwory, Mleko i produkty mleczne, Wyroby garmażeryjne, Ryby i przetwory rybne, Wyroby cukiernicze i ciastkarskie, słodycze Liczba Listeria monocytogenes\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 11290-2:2017-07 Mieso i produkty miesne, Owoce, warzywa i przetwory, Mleko i produkty mleczne, Wyroby garmazeryjne, Ryby i przetwory rybne, Wyroby cukiernicze i ciastkarskie, slodycze Liczba Listeria monocytogenes\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 11290-2:2017-07","categories":["food","microbiology"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Listeria monocytogenes count","search_en":"Meat and meat products, Fruit, vegetables and their preserves, Milk and milk products, Delicatessen products, Fish and fish products, Confectionery and bakery products, sweets Listeria monocytogenes count Plate method (spread plate) Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 11290-2:2017-07","technique_en":"Plate method (spread plate)","test_object_en":"Meat and meat products, Fruit, vegetables and their preserves, Milk and milk products, Delicatessen products, Fish and fish products, Confectionery and bakery products, sweets","search_zh":"单核细胞增生李斯特氏菌计数 平板法（表面涂布） 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 11290-2:2017-07","technique_zh":"平板法（表面涂布）","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_zh":"单核细胞增生李斯特氏菌计数"},{"_id":"6a7d78cb0636ba417e41a280","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Mięso i produkty mięsne, Zboża i przetwory zbożowe, Mleko i produkty mleczne, Napoje, Wyroby garmażeryjne, Jaja i produkty jajeczne","methodology":"Liczba Enterobacteriaceae","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba Enterobacteriaceae\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 21528-2:2017-08","norm_bases":["PN-EN ISO 21528-2:2017-08"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i produkty mięsne, Zboża i przetwory zbożowe, Mleko i produkty mleczne, Napoje, Wyroby garmażeryjne, Jaja i produkty jajeczne Liczba Enterobacteriaceae\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 21528-2:2017-08 Mieso i produkty miesne, Zboza i przetwory zbozowe, Mleko i produkty mleczne, Napoje, Wyroby garmazeryjne, Jaja i produkty jajeczne Liczba Enterobacteriaceae\nMetoda plytkowa (posiew wglebny) PN-EN ISO 21528-2:2017-08","categories":["food"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Enterobacteriaceae count","search_en":"Meat and meat products, Cereals and cereal products, Milk and dairy products, Beverages, Delicatessen products, Eggs and egg products Enterobacteriaceae count Plate method (pour plate) Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 21528-2:2017-08","technique_en":"Plate method (pour plate)","test_object_en":"Meat and meat products, Cereals and cereal products, Milk and dairy products, Beverages, Delicatessen products, Eggs and egg products","methodology_zh":"肠杆菌科（Enterobacteriaceae）计数","search_zh":"肠杆菌科（Enterobacteriaceae）计数 平板法（倾注培养） 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 21528-2:2017-08","technique_zh":"平板法（倾注培养）","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów"},{"_id":"6a7d78cb0636ba417e41a281","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Mięso i produkty mięsne, Napoje, Wyroby garmażeryjne, Owoce, warzywa i przetwory","methodology":"Liczba β glukoronidazo-dodatnich, Escherichia coli","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba β glukoronidazo-dodatnich, Escherichia coli\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 16649-2:2004","norm_bases":["PN-ISO 16649-2:2004"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i produkty mięsne, Napoje, Wyroby garmażeryjne, Owoce, warzywa i przetwory Liczba β glukoronidazo-dodatnich, Escherichia coli\nMetoda płytkowa (posiew wgłębny) PN-ISO 16649-2:2004 Mieso i produkty miesne, Napoje, Wyroby garmazeryjne, Owoce, warzywa i przetwory Liczba β glukoronidazo-dodatnich, Escherichia coli\nMetoda plytkowa (posiew wglebny) PN-ISO 16649-2:2004","categories":["food","microbiology"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Count of β glucuronidase-positive, Escherichia coli","search_en":"Meat and meat products, Beverages, Delicatessen products, Fruit, vegetables and their products Count of β glucuronidase-positive, Escherichia coli Plate method (pour plate) Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-ISO 16649-2:2004","technique_en":"Plate method (pour plate)","test_object_en":"Meat and meat products, Beverages, Delicatessen products, Fruit, vegetables and their products","search_zh":"平板法（倾注培养） 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-ISO 16649-2:2004","technique_zh":"平板法（倾注培养）","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów"},{"_id":"6a7d78cb0636ba417e41a282","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Mięso i wyroby mięsne","methodology":"Obecność bakterii z grupy coli","parameters":[],"technique":"Metoda hodowlana","techniques":["Metoda hodowlana"],"computed":[],"activity":"Obecność bakterii z grupy coli\nMetoda hodowlana","reference":"PN-ISO 4831:2007","norm_bases":["PN-ISO 4831:2007"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i wyroby mięsne Obecność bakterii z grupy coli\nMetoda hodowlana PN-ISO 4831:2007 Mieso i wyroby miesne Obecnosc bakterii z grupy coli\nMetoda hodowlana PN-ISO 4831:2007","categories":["food","microbiology"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Presence of coliform bacteria","search_en":"Meat and meat products Presence of coliform bacteria Culture method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-ISO 4831:2007","technique_en":"Culture method","test_object_en":"Meat and meat products","search_zh":"肉与肉制品 大肠菌群的检出 培养法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-ISO 4831:2007","technique_zh":"培养法","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_zh":"大肠菌群的检出","test_object_zh":"肉与肉制品"},{"_id":"6a7d78cb0636ba417e41a283","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Żywność o aktywności wody większej niż 0,95","methodology":"Liczba drożdży i pleśni","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba drożdży i pleśni\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 21527-1:2009","norm_bases":["PN-EN ISO 21527-1:2009"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność o aktywności wody większej niż 0,95 Liczba drożdży i pleśni\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 21527-1:2009 Zywnosc o aktywnosci wody wiekszej niz 0,95 Liczba drozdzy i plesni\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 21527-1:2009","categories":["water","food"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Yeast and mould count","search_en":"Food with water activity greater than 0,95 Yeast and mould count Plate method (spread plate) Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 21527-1:2009","technique_en":"Plate method (spread plate)","test_object_en":"Food with water activity greater than 0,95","methodology_zh":"酵母菌与霉菌计数","search_zh":"水分活度大于 0,95 的食品 酵母菌与霉菌计数 平板法（表面涂布） 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 21527-1:2009","technique_zh":"平板法（表面涂布）","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","test_object_zh":"水分活度大于 0,95 的食品"},{"_id":"6a7d78cb0636ba417e41a284","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Sampling for microbiological testing","search_en":"Water (including swimming pool water), Water intended for human consumption Sampling for microbiological testing Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 19458:2007","test_object_en":"Water (including swimming pool water), Water intended for human consumption","methodology_zh":"微生物检测用样品采集","search_zh":"水（含游泳池水）、生活饮用水 微生物检测用样品采集 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 19458:2007","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a7d78cb0636ba417e41a285","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 36°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 36°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 36°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 36°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Total viable count at 36°C","search_en":"Water (including swimming pool water), Water intended for human consumption Total viable count at 36°C Plate method (pour plate) Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water (including swimming pool water), Water intended for human consumption","methodology_zh":"36°C 微生物总数","search_zh":"水（含游泳池水）、生活饮用水 36°C 微生物总数 平板法（倾注培养） 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a7d78cb0636ba417e41a286","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Liczba bakterii Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12/ A1:2017-04"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04 Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","categories":["microbiology","water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Escherichia coli count","search_en":"Water (including swimming pool water), Water intended for human consumption Escherichia coli count Membrane filtration method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), Water intended for human consumption","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水（含游泳池水）、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","technique_zh":"膜过滤法","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a7d78cb0636ba417e41a287","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Liczba bakterii Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Liczba bakterii Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Liczba bakterii Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water","microbiology"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Pseudomonas aeruginosa bacteria count","search_en":"Water (including swimming pool water), Water intended for human consumption Pseudomonas aeruginosa bacteria count Membrane filtration method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 16266:2009","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), Water intended for human consumption","search_zh":"水（含游泳池水）、生活饮用水 铜绿假单胞菌数 膜过滤法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 16266:2009","technique_zh":"膜过滤法","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","test_object_zh":"水（含游泳池水）、生活饮用水","methodology_zh":"铜绿假单胞菌数"},{"_id":"6a7d78cb0636ba417e41a288","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Liczba bakterii z rodzaju Legionella, Matryca A, Procedura 5 (pożywka BCYE), 7 (pożywka GVPC)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii z rodzaju Legionella, Matryca A, Procedura 5 (pożywka BCYE), 7 (pożywka GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731-2017-08 | PN-EN ISO 11731-2017-08/ Ap1:2019-12","norm_bases":["PN-EN ISO 11731-2017-08","PN-EN ISO 11731-2017-08/ Ap1:2019-12"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Liczba bakterii z rodzaju Legionella, Matryca A, Procedura 5 (pożywka BCYE), 7 (pożywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731-2017-08 | PN-EN ISO 11731-2017-08/ Ap1:2019-12 Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Liczba bakterii z rodzaju Legionella, Matryca A, Procedura 5 (pozywka BCYE), 7 (pozywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731-2017-08 | PN-EN ISO 11731-2017-08/ Ap1:2019-12","categories":["microbiology","water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Count of bacteria of the genus Legionella, Matrix A, Procedure 5 (BCYE medium), 7 (GVPC medium)","search_en":"Water (including swimming pool water), Water intended for human consumption Count of bacteria of the genus Legionella, Matrix A, Procedure 5 (BCYE medium), 7 (GVPC medium) Membrane filtration method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 11731-2017-08 | PN-EN ISO 11731-2017-08/ Ap1:2019-12","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), Water intended for human consumption","search_zh":"水（含游泳池水）、生活饮用水 军团菌属细菌数，基质 A，程序 5（培养基 BCYE）、7（培养基 GVPC） 膜过滤法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 11731-2017-08 | PN-EN ISO 11731-2017-08/ Ap1:2019-12","technique_zh":"膜过滤法","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","test_object_zh":"水（含游泳池水）、生活饮用水","methodology_zh":"军团菌属细菌数，基质 A，程序 5（培养基 BCYE）、7（培养基 GVPC）"},{"_id":"6a7d78cb0636ba417e41a289","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba mikroorganizmów w 22°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba mikroorganizmów w 22°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba mikroorganizmów w 22°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Liczba mikroorganizmow w 22°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Microorganism count at 22°C","search_en":"Water, Water intended for human consumption Microorganism count at 22°C Plate method (pour plate) Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 22°C 微生物数 平板法（倾注培养） 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_zh":"22°C 微生物数"},{"_id":"6a7d78cb0636ba417e41a28a","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12/ A1:2017-04"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04 Woda, Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","categories":["water","microbiology"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Coliform bacteria count","search_en":"Water, Water intended for human consumption Coliform bacteria count Membrane filtration method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów"},{"_id":"6a7d78cb0636ba417e41a28b","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, Woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Intestinal enterococci count","search_en":"Water, Water intended for human consumption Intestinal enterococci count Membrane filtration method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"粪肠球菌计数","search_zh":"水、生活饮用水 粪肠球菌计数 膜过滤法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów"},{"_id":"6a7d78cb0636ba417e41a28c","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda","methodology":"Najbardziej prawdopodobna liczba, Escherichia coli","parameters":[],"technique":"Metoda zminiaturyzowana (NPL)","techniques":["Metoda zminiaturyzowana (NPL)"],"computed":[],"activity":"Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda zminiaturyzowana (NPL)","reference":"PN-EN ISO 9308-3:2002","norm_bases":["PN-EN ISO 9308-3:2002"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda zminiaturyzowana (NPL) PN-EN ISO 9308-3:2002 Woda Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda zminiaturyzowana (NPL) PN-EN ISO 9308-3:2002","categories":["water","microbiology"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Most probable number, Escherichia coli","search_en":"Water Most probable number, Escherichia coli Miniaturized method (MPN) Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 9308-3:2002","technique_en":"Miniaturized method (MPN)","test_object_en":"Water","methodology_zh":"大肠埃希氏菌（Escherichia coli）最可能数（MPN）","search_zh":"水 大肠埃希氏菌（Escherichia coli）最可能数（MPN） 微量法（MPN） 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-EN ISO 9308-3:2002","test_object_zh":"水","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","technique_zh":"微量法（MPN）"},{"_id":"6a7d78cb0636ba417e41a28d","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura"},{"name":"Zakres","range":"(0,0 – 50,0) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0,0 – 50,0) oC","reference":"PN-ISO 5667-5:2017-10 | PN-77/C- 04584","norm_bases":["PN-ISO 5667-5:2017-10","PN-77/C- 04584"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0,0 – 50,0) oC PN-ISO 5667-5:2017-10 | PN-77/C- 04584 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0,0 – 50,0) oC PN-ISO 5667-5:2017-10 | PN-77/C- 04584","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature"},{"name":"Range","range":"(0,0 – 50,0) oC"}],"search_en":"Water intended for human consumption Sampling for chemical and physical testing Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Temperature Range PN-ISO 5667-5:2017-10 | PN-77/C- 04584","test_object_en":"Water intended for human consumption","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"温度"},{"name":"范围","range":"(0,0 – 50,0) oC"}],"search_zh":"生活饮用水 化学与物理检测用样品采集 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 温度 范围 PN-ISO 5667-5:2017-10 | PN-77/C- 04584","test_object_zh":"生活饮用水","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów"},{"_id":"6a7d78cb0636ba417e41a28e","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda powierzchniowa","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura"},{"name":"Zakres","range":"(0,0 – 50,0) oC"}],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0,0 – 50,0) oC\nMetoda manualna","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5 i 7.6 | PN-77/C- 04584","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5 i 7.6","PN-77/C- 04584"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda powierzchniowa Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0,0 – 50,0) oC\nMetoda manualna PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5 i 7.6 | PN-77/C- 04584 Woda powierzchniowa Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0,0 – 50,0) oC\nMetoda manualna PN-EN ISO 5667-6:2016-12 z wylaczeniem pkt 7.5 i 7.6 | PN-77/C- 04584","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature"},{"name":"Range","range":"(0,0 – 50,0) oC"}],"search_en":"Surface water Sampling for chemical and physical testing Manual method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Temperature Range PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5 i 7.6 | PN-77/C- 04584","technique_en":"Manual method","test_object_en":"Surface water","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"温度"},{"name":"范围","range":"(0,0 – 50,0) oC"}],"search_zh":"地表水 化学与物理检测用样品采集 手工法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 温度 范围 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5 i 7.6 | PN-77/C- 04584","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","technique_zh":"手工法","test_object_zh":"地表水"},{"_id":"6a7d78cb0636ba417e41a28f","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(0,05 – 5,0) mmol/l"},{"name":"Zakres","range":"(5 – 500) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres:\nZakres (0,05 – 5,0) mmol/l\nZakres (5 – 500) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres:\nZakres (0,05 – 5,0) mmol/l\nZakres (5 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres:\nZakres (0,05 – 5,0) mmol/l\nZakres (5 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(0,05 – 5,0) mmol/l"},{"name":"Range","range":"(5 – 500) mg/l CaCO3"}],"search_en":"Water, Water intended for human consumption Total content of calcium and magnesium (total hardness) Titrimetric method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(0,05 – 5,0) mmol/l"},{"name":"范围","range":"(5 – 500) mg/l CaCO3"}],"search_zh":"水、生活饮用水 钙与镁总量（总硬度） 滴定法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów"},{"_id":"6a7d78cb0636ba417e41a290","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 250) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 250) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie chlorków\nZakres (5,0 – 250) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, Woda do spozycia przez ludzi Stezenie chlorkow\nZakres (5,0 – 250) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 250) mg/l"}],"search_en":"Water, Water intended for human consumption Chloride concentration Titrimetric method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 250) mg/l"}],"search_zh":"水、生活饮用水 氯化物浓度 滴定法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów"},{"_id":"6a7d78cb0636ba417e41a291","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(2,0 – 45) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (2,0 – 45) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 pkt. 6 | PN-EN ISO 7887:2012/Ap1:2015-06 pkt. 6","norm_bases":["PN-EN ISO 7887:2012 pkt. 6","PN-EN ISO 7887:2012/Ap1:2015-06 pkt. 6"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Barwa\nZakres (2,0 – 45) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 pkt. 6 | PN-EN ISO 7887:2012/Ap1:2015-06 pkt. 6 Woda, Woda do spozycia przez ludzi Barwa\nZakres (2,0 – 45) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 pkt. 6 | PN-EN ISO 7887:2012/Ap1:2015-06 pkt. 6","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(2,0 – 45) mg/l Pt"}],"search_en":"Water, Water intended for human consumption Colour Spectrophotometric method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range PN-EN ISO 7887:2012 pkt. 6 | PN-EN ISO 7887:2012/Ap1:2015-06 pkt. 6","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(2,0 – 45) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 分光光度法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 PN-EN ISO 7887:2012 pkt. 6 | PN-EN ISO 7887:2012/Ap1:2015-06 pkt. 6","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów"},{"_id":"6a7d78cb0636ba417e41a292","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,01 – 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (0,01 – 1,0) mg/l\nMetoda spektrofotometryczna","reference":"Test kuwetowy Merck nr 1.14770.0001 wydanie z 07.2024 r.","norm_bases":["Test kuwetowy Merck nr 1.14770.0001 wydanie z 07.2024 r."],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie manganu\nZakres (0,01 – 1,0) mg/l\nMetoda spektrofotometryczna Test kuwetowy Merck nr 1.14770.0001 wydanie z 07.2024 r. Woda, Woda do spozycia przez ludzi Stezenie manganu\nZakres (0,01 – 1,0) mg/l\nMetoda spektrofotometryczna Test kuwetowy Merck nr 1.14770.0001 wydanie z 07.2024 r.","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(0,01 – 1,0) mg/l"}],"search_en":"Water, Water intended for human consumption Manganese concentration Spectrophotometric method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range Test kuwetowy Merck nr 1.14770.0001 wydanie z 07.2024 r.","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,01 – 1,0) mg/l"}],"search_zh":"水、生活饮用水 锰浓度 分光光度法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 Test kuwetowy Merck nr 1.14770.0001 wydanie z 07.2024 r.","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów"},{"_id":"6a7d78cb0636ba417e41a293","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,05 – 3,28) mg/l NO2"},{"name":"Zakres","range":"(0,02 – 1,0) mg/l N-NO2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres:\nZakres (0,05 – 3,28) mg/l NO2\nZakres (0,02 – 1,0) mg/l N-NO2\nMetoda spektrofotometryczna","reference":"Test kuwetowy Merck nr 1.14776.0001 wydanie z 02.2024 r.","norm_bases":["Test kuwetowy Merck nr 1.14776.0001 wydanie z 02.2024 r."],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotynów\nZakres:\nZakres (0,05 – 3,28) mg/l NO2\nZakres (0,02 – 1,0) mg/l N-NO2\nMetoda spektrofotometryczna Test kuwetowy Merck nr 1.14776.0001 wydanie z 02.2024 r. Woda, Woda do spozycia przez ludzi Stezenie azotynow\nZakres:\nZakres (0,05 – 3,28) mg/l NO2\nZakres (0,02 – 1,0) mg/l N-NO2\nMetoda spektrofotometryczna Test kuwetowy Merck nr 1.14776.0001 wydanie z 02.2024 r.","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,05 – 3,28) mg/l NO2"},{"name":"Range","range":"(0,02 – 1,0) mg/l N-NO2"}],"search_en":"Water, Water intended for human consumption Nitrite concentration Spectrophotometric method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range Range Test kuwetowy Merck nr 1.14776.0001 wydanie z 02.2024 r.","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 3,28) mg/l NO2"},{"name":"范围","range":"(0,02 – 1,0) mg/l N-NO2"}],"search_zh":"水、生活饮用水 亚硝酸盐浓度 分光光度法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 范围 Test kuwetowy Merck nr 1.14776.0001 wydanie z 02.2024 r.","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów"},{"_id":"6a7d78cb0636ba417e41a294","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,100 – 3,80) mg/l NH4"},{"name":"Zakres","range":"(0,077– 2,95) mg/l N-NH4"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres:\nZakres (0,100 – 3,80) mg/l NH4\nZakres (0,077– 2,95) mg/l N-NH4\nMetoda spektrofotometryczna","reference":"Test kuwetowy Merck nr 1.14752.0001 wydanie z 02.2024 r.","norm_bases":["Test kuwetowy Merck nr 1.14752.0001 wydanie z 02.2024 r."],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres:\nZakres (0,100 – 3,80) mg/l NH4\nZakres (0,077– 2,95) mg/l N-NH4\nMetoda spektrofotometryczna Test kuwetowy Merck nr 1.14752.0001 wydanie z 02.2024 r. Woda, Woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres:\nZakres (0,100 – 3,80) mg/l NH4\nZakres (0,077– 2,95) mg/l N-NH4\nMetoda spektrofotometryczna Test kuwetowy Merck nr 1.14752.0001 wydanie z 02.2024 r.","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,100 – 3,80) mg/l NH4"},{"name":"Range","range":"(0,077– 2,95) mg/l N-NH4"}],"search_en":"Water, Water intended for human consumption Ammonium ion concentration Spectrophotometric method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range Range Test kuwetowy Merck nr 1.14752.0001 wydanie z 02.2024 r.","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,100 – 3,80) mg/l NH4"},{"name":"范围","range":"(0,077– 2,95) mg/l N-NH4"}],"search_zh":"水、生活饮用水 铵离子浓度 分光光度法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 范围 Test kuwetowy Merck nr 1.14752.0001 wydanie z 02.2024 r.","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów"},{"_id":"6a7d78cb0636ba417e41a295","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(80 – 5000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (80 – 5000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (80 – 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (80 – 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(80 – 5000) μS/cm"}],"search_en":"Water, Water intended for human consumption Electrical conductivity Conductometric method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(80 – 5000) μS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów"},{"_id":"6a7d78cb0636ba417e41a296","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,01 – 5,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,01 – 5,00) mg/l\nMetoda spektrofotometryczna","reference":"Test kuwetowy Merck nr 1.14761.0001 wydanie z 03.2024 r.","norm_bases":["Test kuwetowy Merck nr 1.14761.0001 wydanie z 03.2024 r."],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie żelaza ogólnego\nZakres (0,01 – 5,00) mg/l\nMetoda spektrofotometryczna Test kuwetowy Merck nr 1.14761.0001 wydanie z 03.2024 r. Woda, Woda do spozycia przez ludzi Stezenie zelaza ogolnego\nZakres (0,01 – 5,00) mg/l\nMetoda spektrofotometryczna Test kuwetowy Merck nr 1.14761.0001 wydanie z 03.2024 r.","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,01 – 5,00) mg/l"}],"search_en":"Water, Water intended for human consumption Total iron concentration Spectrophotometric method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range Test kuwetowy Merck nr 1.14761.0001 wydanie z 03.2024 r.","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,01 – 5,00) mg/l"}],"search_zh":"水、生活饮用水 总铁浓度 分光光度法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 Test kuwetowy Merck nr 1.14761.0001 wydanie z 03.2024 r.","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów"},{"_id":"6a7d78cb0636ba417e41a297","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,5 – 15) mg/l"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,5 – 15) mg/l\nMetoda elektrochemiczna","reference":"PN-EN ISO 5814:2013-04","norm_bases":["PN-EN ISO 5814:2013-04"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie tlenu rozpuszczonego\nZakres (0,5 – 15) mg/l\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04 Woda, Woda do spozycia przez ludzi Stezenie tlenu rozpuszczonego\nZakres (0,5 – 15) mg/l\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04","categories":["water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(0,5 – 15) mg/l"}],"search_en":"Water, Water intended for human consumption Dissolved oxygen concentration Electrochemical method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range PN-EN ISO 5814:2013-04","technique_en":"Electrochemical method","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,5 – 15) mg/l"}],"search_zh":"水、生活饮用水 溶解氧浓度 电化学法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 PN-EN ISO 5814:2013-04","technique_zh":"电化学法","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_zh":"溶解氧浓度"},{"_id":"6a7d78cb0636ba417e41a298","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,5 – 10) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,5 – 10) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Indeks nadmanganianowy\nZakres (0,5 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Indeks nadmanganianowy\nZakres (0,5 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,5 – 10) mg/l O2"}],"search_en":"Water (including swimming pool water), Water intended for human consumption Permanganate index Titrimetric method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water (including swimming pool water), Water intended for human consumption","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,5 – 10) mg/l O2"}],"search_zh":"水（含游泳池水）、生活饮用水 高锰酸盐指数 滴定法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a7d78cb0636ba417e41a299","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Water (including swimming pool water), Water intended for human consumption pH Potentiometric method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water (including swimming pool water), Water intended for human consumption","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"水（含游泳池水）、生活饮用水 pH 值 电位法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a7d78cb0636ba417e41a29a","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,15 – 30) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,15 – 30) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Mętność\nZakres (0,15 – 30) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Metnosc\nZakres (0,15 – 30) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,15 – 30) NTU"}],"search_en":"Water (including swimming pool water), Water intended for human consumption Turbidity Nephelometric method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water (including swimming pool water), Water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,15 – 30) NTU"}],"search_zh":"水（含游泳池水）、生活饮用水 浊度 浊度法（散射法） 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a7d78cb0636ba417e41a29b","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,02 – 2,00) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,02 – 2,00) mg/l\nMetoda kolorymetryczna","reference":"PB-47 wyd. 02 z dnia 19.01.2016 | na podstawie testu odczynnikowego firmy Hach nr 8021","norm_bases":["PB-47 wyd. 02 z dnia 19.01.2016","na podstawie testu odczynnikowego firmy Hach nr 8021"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Stężenie chloru wolnego\nZakres (0,02 – 2,00) mg/l\nMetoda kolorymetryczna PB-47 wyd. 02 z dnia 19.01.2016 | na podstawie testu odczynnikowego firmy Hach nr 8021 Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Stezenie chloru wolnego\nZakres (0,02 – 2,00) mg/l\nMetoda kolorymetryczna PB-47 wyd. 02 z dnia 19.01.2016 | na podstawie testu odczynnikowego firmy Hach nr 8021","categories":["water"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,02 – 2,00) mg/l"}],"search_en":"Water (including swimming pool water), Water intended for human consumption Free chlorine concentration Colorimetric method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range PB-47 wyd. 02 z dnia 19.01.2016 | na podstawie testu odczynnikowego firmy Hach nr 8021","technique_en":"Colorimetric method","test_object_en":"Water (including swimming pool water), Water intended for human consumption","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 2,00) mg/l"}],"search_zh":"水（含游泳池水）、生活饮用水 游离氯浓度 比色法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 PB-47 wyd. 02 z dnia 19.01.2016 | na podstawie testu odczynnikowego firmy Hach nr 8021","technique_zh":"比色法","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a7d78cb0636ba417e41a29c","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Stężenie chloru ogólnego","parameters":[{"name":"Zakres","range":"(0,02 – 2,00) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Stężenie chloru ogólnego\nZakres (0,02 – 2,00) mg/l\nMetoda kolorymetryczna","reference":"PB-47 wyd. 02 z dnia 19.01.2016 | na podstawie testu odczynnikowego firmy Hach nr 8167","norm_bases":["PB-47 wyd. 02 z dnia 19.01.2016","na podstawie testu odczynnikowego firmy Hach nr 8167"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Stężenie chloru ogólnego\nZakres (0,02 – 2,00) mg/l\nMetoda kolorymetryczna PB-47 wyd. 02 z dnia 19.01.2016 | na podstawie testu odczynnikowego firmy Hach nr 8167 Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Stezenie chloru ogolnego\nZakres (0,02 – 2,00) mg/l\nMetoda kolorymetryczna PB-47 wyd. 02 z dnia 19.01.2016 | na podstawie testu odczynnikowego firmy Hach nr 8167","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Total chlorine concentration","parameters_en":[{"name":"Range","range":"(0,02 – 2,00) mg/l"}],"search_en":"Water (including swimming pool water), Water intended for human consumption Total chlorine concentration Colorimetric method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range PB-47 wyd. 02 z dnia 19.01.2016 | na podstawie testu odczynnikowego firmy Hach nr 8167","technique_en":"Colorimetric method","test_object_en":"Water (including swimming pool water), Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,02 – 2,00) mg/l"}],"search_zh":"水（含游泳池水）、生活饮用水 总氯浓度 比色法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 PB-47 wyd. 02 z dnia 19.01.2016 | na podstawie testu odczynnikowego firmy Hach nr 8167","technique_zh":"比色法","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_zh":"总氯浓度","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a7d78cb0636ba417e41a29d","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Stężenie chloru związanego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chloru związanego (z obliczeń)","reference":"PB-47 wyd. 02 z dnia 19.01.2016 | na podstawie testu odczynnikowego firmy Hach nr 8021 i nr 8167","norm_bases":["PB-47 wyd. 02 z dnia 19.01.2016","na podstawie testu odczynnikowego firmy Hach nr 8021 i nr 8167"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Stężenie chloru związanego (z obliczeń) PB-47 wyd. 02 z dnia 19.01.2016 | na podstawie testu odczynnikowego firmy Hach nr 8021 i nr 8167 Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Stezenie chloru zwiazanego (z obliczen) PB-47 wyd. 02 z dnia 19.01.2016 | na podstawie testu odczynnikowego firmy Hach nr 8021 i nr 8167","categories":["water"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Combined chlorine concentration (calculated)","search_en":"Water (including swimming pool water), Water intended for human consumption Combined chlorine concentration (calculated) Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PB-47 wyd. 02 z dnia 19.01.2016 | na podstawie testu odczynnikowego firmy Hach nr 8021 i nr 8167","test_object_en":"Water (including swimming pool water), Water intended for human consumption","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_zh":"化合氯浓度（计算值）","search_zh":"水（含游泳池水）、生活饮用水 化合氯浓度（计算值） 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PB-47 wyd. 02 z dnia 19.01.2016 | na podstawie testu odczynnikowego firmy Hach nr 8021 i nr 8167","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a7d78cb0636ba417e41a29e","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(1,5 – 110) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (1,5 – 110) mg/l\nMetoda spektrofotometryczna","reference":"Test kuwetowy Merck nr 1.09713.0001 wydanie z 05.2025 r.","norm_bases":["Test kuwetowy Merck nr 1.09713.0001 wydanie z 05.2025 r."],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Stężenie azotanów\nZakres (1,5 – 110) mg/l\nMetoda spektrofotometryczna Test kuwetowy Merck nr 1.09713.0001 wydanie z 05.2025 r. Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Stezenie azotanow\nZakres (1,5 – 110) mg/l\nMetoda spektrofotometryczna Test kuwetowy Merck nr 1.09713.0001 wydanie z 05.2025 r.","categories":["water"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(1,5 – 110) mg/l"}],"search_en":"Water (including swimming pool water), Water intended for human consumption Nitrate concentration Spectrophotometric method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range Test kuwetowy Merck nr 1.09713.0001 wydanie z 05.2025 r.","technique_en":"Spectrophotometric method","test_object_en":"Water (including swimming pool water), Water intended for human consumption","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(1,5 – 110) mg/l"}],"search_zh":"水（含游泳池水）、生活饮用水 硝酸盐浓度 分光光度法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 Test kuwetowy Merck nr 1.09713.0001 wydanie z 05.2025 r.","technique_zh":"分光光度法","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a7d78cb0636ba417e41a29f","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda","methodology":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr","parameters":[{"name":"Zakres","range":"(10 – 1500) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (10 – 1500) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (10 – 1500) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (10 – 1500) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Chemical oxygen demand – COD-Cr","parameters_en":[{"name":"Range","range":"(10 – 1500) mg/l O2"}],"search_en":"Water Chemical oxygen demand – COD-Cr Spectrophotometric method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(10 – 1500) mg/l O2"}],"search_zh":"水 化学需氧量（COD-Cr） 分光光度法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a7d78cb0636ba417e41a2a0","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,07 – 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,07 – 5,0) mg/l\nMetoda spektrofotometryczna","reference":"Test kuwetowy Merck nr 1.14848.0001 wydanie z 11.2024 r.","norm_bases":["Test kuwetowy Merck nr 1.14848.0001 wydanie z 11.2024 r."],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie fosforu ogólnego\nZakres (0,07 – 5,0) mg/l\nMetoda spektrofotometryczna Test kuwetowy Merck nr 1.14848.0001 wydanie z 11.2024 r. Woda Stezenie fosforu ogolnego\nZakres (0,07 – 5,0) mg/l\nMetoda spektrofotometryczna Test kuwetowy Merck nr 1.14848.0001 wydanie z 11.2024 r.","categories":["water"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,07 – 5,0) mg/l"}],"search_en":"Water Total phosphorus concentration Spectrophotometric method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range Test kuwetowy Merck nr 1.14848.0001 wydanie z 11.2024 r.","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,07 – 5,0) mg/l"}],"search_zh":"水 总磷浓度 分光光度法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 Test kuwetowy Merck nr 1.14848.0001 wydanie z 11.2024 r.","technique_zh":"分光光度法","test_object_zh":"水","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów"},{"_id":"6a7d78cb0636ba417e41a2a1","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(1,0 – 1000) mg/l NH4"},{"name":"Zakres","range":"(0,78 – 780) mg/l N-NH4"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres:\nZakres (1,0 – 1000) mg/l NH4\nZakres (0,78 – 780) mg/l N-NH4\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu amonowego\nZakres:\nZakres (1,0 – 1000) mg/l NH4\nZakres (0,78 – 780) mg/l N-NH4\nMetoda miareczkowa PN-ISO 5664:2002 Woda, Scieki Stezenie azotu amonowego\nZakres:\nZakres (1,0 – 1000) mg/l NH4\nZakres (0,78 – 780) mg/l N-NH4\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,0 – 1000) mg/l NH4"},{"name":"Range","range":"(0,78 – 780) mg/l N-NH4"}],"search_en":"Water, Wastewater Ammonium nitrogen concentration Titrimetric method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range Range PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Water, Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 1000) mg/l NH4"},{"name":"范围","range":"(0,78 – 780) mg/l N-NH4"}],"search_zh":"水、污水 氨氮浓度 滴定法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"水、污水","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów"},{"_id":"6a7d78cb0636ba417e41a2a2","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(1,0 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (1,0 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu Kjeldahla\nZakres (1,0 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, Scieki Stezenie azotu Kjeldahla\nZakres (1,0 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,0 – 1000) mg/l"}],"search_en":"Water, Wastewater Kjeldahl nitrogen concentration Titrimetric method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water, Wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 1000) mg/l"}],"search_zh":"水、污水 凯氏氮浓度 滴定法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、污水","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów"},{"_id":"6a7d78cb0636ba417e41a2a3","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-15 wydanie 01 z dnia 10.03.2009 r.","norm_bases":["PB-15 wydanie 01 z dnia 10.03.2009 r."],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu ogólnego (z obliczeń) PB-15 wydanie 01 z dnia 10.03.2009 r. Woda, Scieki Stezenie azotu ogolnego (z obliczen) PB-15 wydanie 01 z dnia 10.03.2009 r.","categories":["water"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water, Wastewater Total nitrogen concentration (calculated) Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PB-15 wydanie 01 z dnia 10.03.2009 r.","test_object_en":"Water, Wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"水、污水 总氮浓度（计算值） 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PB-15 wydanie 01 z dnia 10.03.2009 r.","test_object_zh":"水、污水","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów"},{"_id":"6a7d78cb0636ba417e41a2a4","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(1 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, Scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(1 – 6000) mg/l O2"}],"search_en":"Water, Wastewater Biochemical oxygen demand - BOD5 Electrochemical method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(1 – 6000) mg/l O2"}],"search_zh":"水、污水 五日生化需氧量（BOD5） 电化学法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、污水","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a7d78cb0636ba417e41a2a5","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(0,5 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, Scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(0,5 – 6,0) mg/l O2"}],"search_en":"Water, Wastewater Biochemical oxygen demand - BOD5 Electrochemical method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,5 – 6,0) mg/l O2"}],"search_zh":"水、污水 五日生化需氧量（BOD5） 电化学法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、污水","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a7d78cb0636ba417e41a2a6","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Woda, Ścieki, Wody opadowe i roztopowe","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(5,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (5,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki, Wody opadowe i roztopowe Zawiesiny ogólne\nZakres (5,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, Scieki, Wody opadowe i roztopowe Zawiesiny ogolne\nZakres (5,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(5,0 – 1000) mg/l"}],"search_en":"Water, Wastewater, Rainwater and snowmelt water Total suspended solids (TSS) Gravimetric method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater, Rainwater and snowmelt water","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(5,0 – 1000) mg/l"}],"search_zh":"水、废水、雨水与融雪水 总悬浮物 重量法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","test_object_zh":"水、废水、雨水与融雪水"},{"_id":"6a7d78cb0636ba417e41a2a7","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Ścieki, Wody opadowe i roztopowe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura"},{"name":"Zakres","range":"(0,0 – 50,0) oC"}],"technique":"Metoda manualna i automatyczna","techniques":["Metoda manualna i automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0,0 – 50,0) oC\nMetoda manualna i automatyczna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C- 04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C- 04584"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Wody opadowe i roztopowe Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0,0 – 50,0) oC\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 | PN-77/C- 04584 Scieki, Wody opadowe i roztopowe Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0,0 – 50,0) oC\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 | PN-77/C- 04584","categories":["water"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature"},{"name":"Range","range":"(0,0 – 50,0) oC"}],"search_en":"Wastewater, Rainwater and snowmelt water Sampling for chemical and physical testing Manual and automatic method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Temperature Range PN-ISO 5667-10:2021-11 | PN-77/C- 04584","technique_en":"Manual and automatic method","test_object_en":"Wastewater, Rainwater and snowmelt water","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"温度"},{"name":"范围","range":"(0,0 – 50,0) oC"}],"search_zh":"废水、雨水与融雪水 化学与物理检测用样品采集 手工与自动法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C- 04584","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","technique_zh":"手工与自动法","test_object_zh":"废水、雨水与融雪水"},{"_id":"6a7d78cb0636ba417e41a2a8","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Wastewater pH Potentiometric method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"污水 pH 值 电位法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"污水","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów"},{"_id":"6a7d78cb0636ba417e41a2a9","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,077 – 70) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,077 – 70) mg/l\nMetoda spektrofotometryczna","reference":"Test kuwetowy Merck nr 1.14752.0001 wydanie z 02.2024 r","norm_bases":["Test kuwetowy Merck nr 1.14752.0001 wydanie z 02.2024 r"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (0,077 – 70) mg/l\nMetoda spektrofotometryczna Test kuwetowy Merck nr 1.14752.0001 wydanie z 02.2024 r Scieki Stezenie azotu amonowego\nZakres (0,077 – 70) mg/l\nMetoda spektrofotometryczna Test kuwetowy Merck nr 1.14752.0001 wydanie z 02.2024 r","categories":["water"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,077 – 70) mg/l"}],"search_en":"Wastewater Ammonium nitrogen concentration Spectrophotometric method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range Test kuwetowy Merck nr 1.14752.0001 wydanie z 02.2024 r","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,077 – 70) mg/l"}],"search_zh":"污水 氨氮浓度 分光光度法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 Test kuwetowy Merck nr 1.14752.0001 wydanie z 02.2024 r","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów"},{"_id":"6a7d78cb0636ba417e41a2aa","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(1,5 – 110) mg/l NO3"},{"name":"Zakres","range":"(0,34 – 24,8) mg/l N-NO3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres:\nZakres (1,5 – 110) mg/l NO3\nZakres (0,34 – 24,8) mg/l N-NO3\nMetoda spektrofotometryczna","reference":"Test kuwetowy Merck nr 1.09713.0001 wydanie z 05.2025 r.","norm_bases":["Test kuwetowy Merck nr 1.09713.0001 wydanie z 05.2025 r."],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotanów\nZakres:\nZakres (1,5 – 110) mg/l NO3\nZakres (0,34 – 24,8) mg/l N-NO3\nMetoda spektrofotometryczna Test kuwetowy Merck nr 1.09713.0001 wydanie z 05.2025 r. Scieki Stezenie azotanow\nZakres:\nZakres (1,5 – 110) mg/l NO3\nZakres (0,34 – 24,8) mg/l N-NO3\nMetoda spektrofotometryczna Test kuwetowy Merck nr 1.09713.0001 wydanie z 05.2025 r.","categories":["water"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(1,5 – 110) mg/l NO3"},{"name":"Range","range":"(0,34 – 24,8) mg/l N-NO3"}],"search_en":"Wastewater Nitrate concentration Spectrophotometric method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range Range Test kuwetowy Merck nr 1.09713.0001 wydanie z 05.2025 r.","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(1,5 – 110) mg/l NO3"},{"name":"范围","range":"(0,34 – 24,8) mg/l N-NO3"}],"search_zh":"污水 硝酸盐浓度 分光光度法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 范围 Test kuwetowy Merck nr 1.09713.0001 wydanie z 05.2025 r.","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów"},{"_id":"6a7d78cb0636ba417e41a2ab","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,02 – 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,02 – 5,0) mg/l\nMetoda spektrofotometryczna","reference":"Test kuwetowy Merck nr 1.14776.0001 wydanie z 02.2024 r.","norm_bases":["Test kuwetowy Merck nr 1.14776.0001 wydanie z 02.2024 r."],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotynowego\nZakres (0,02 – 5,0) mg/l\nMetoda spektrofotometryczna Test kuwetowy Merck nr 1.14776.0001 wydanie z 02.2024 r. Scieki Stezenie azotu azotynowego\nZakres (0,02 – 5,0) mg/l\nMetoda spektrofotometryczna Test kuwetowy Merck nr 1.14776.0001 wydanie z 02.2024 r.","categories":["water"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,02 – 5,0) mg/l"}],"search_en":"Wastewater Nitrite nitrogen concentration Spectrophotometric method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range Test kuwetowy Merck nr 1.14776.0001 wydanie z 02.2024 r.","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 5,0) mg/l"}],"search_zh":"污水 亚硝态氮浓度 分光光度法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 Test kuwetowy Merck nr 1.14776.0001 wydanie z 02.2024 r.","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów"},{"_id":"6a7d78cb0636ba417e41a2ac","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,07 – 50,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,07 – 50,0) mg/l\nMetoda spektrofotometryczna","reference":"Test kuwetowy Merck nr 1.14848.0001 wydanie z 11.2024 r.","norm_bases":["Test kuwetowy Merck nr 1.14848.0001 wydanie z 11.2024 r."],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,07 – 50,0) mg/l\nMetoda spektrofotometryczna Test kuwetowy Merck nr 1.14848.0001 wydanie z 11.2024 r. Scieki Stezenie fosforu ogolnego\nZakres (0,07 – 50,0) mg/l\nMetoda spektrofotometryczna Test kuwetowy Merck nr 1.14848.0001 wydanie z 11.2024 r.","categories":["water"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,07 – 50,0) mg/l"}],"search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range Test kuwetowy Merck nr 1.14848.0001 wydanie z 11.2024 r.","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,07 – 50,0) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 Test kuwetowy Merck nr 1.14848.0001 wydanie z 11.2024 r.","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów"},{"_id":"6a7d78cb0636ba417e41a2ad","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(80 – 5000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (80 – 5000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Przewodność elektryczna właściwa\nZakres (80 – 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Scieki Przewodnosc elektryczna wlasciwa\nZakres (80 – 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(80 – 5000) μS/cm"}],"search_en":"Wastewater Electrical conductivity Conductometric method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(80 – 5000) μS/cm"}],"search_zh":"污水 电导率 电导法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"污水","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów"},{"_id":"6a7d78cb0636ba417e41a2ae","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,01 – 5,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,01 – 5,00) mg/l\nMetoda spektrofotometryczna","reference":"Test kuwetowy Merck nr 1.14761.0001 wydanie z 03.2024 r.","norm_bases":["Test kuwetowy Merck nr 1.14761.0001 wydanie z 03.2024 r."],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie żelaza ogólnego\nZakres (0,01 – 5,00) mg/l\nMetoda spektrofotometryczna Test kuwetowy Merck nr 1.14761.0001 wydanie z 03.2024 r. Scieki Stezenie zelaza ogolnego\nZakres (0,01 – 5,00) mg/l\nMetoda spektrofotometryczna Test kuwetowy Merck nr 1.14761.0001 wydanie z 03.2024 r.","categories":["water"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,01 – 5,00) mg/l"}],"search_en":"Wastewater Total iron concentration Spectrophotometric method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range Test kuwetowy Merck nr 1.14761.0001 wydanie z 03.2024 r.","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,01 – 5,00) mg/l"}],"search_zh":"污水 总铁浓度 分光光度法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 Test kuwetowy Merck nr 1.14761.0001 wydanie z 03.2024 r.","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów"},{"_id":"6a7d78cb0636ba417e41a2af","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,5 – 15) mg/l"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,5 – 15) mg/l\nMetoda elektrochemiczna","reference":"PN-EN ISO 5814:2013-04","norm_bases":["PN-EN ISO 5814:2013-04"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie tlenu rozpuszczonego\nZakres (0,5 – 15) mg/l\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04 Scieki Stezenie tlenu rozpuszczonego\nZakres (0,5 – 15) mg/l\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04","categories":["water"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(0,5 – 15) mg/l"}],"search_en":"Wastewater Dissolved oxygen concentration Electrochemical method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range PN-EN ISO 5814:2013-04","technique_en":"Electrochemical method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,5 – 15) mg/l"}],"search_zh":"污水 溶解氧浓度 电化学法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 PN-EN ISO 5814:2013-04","technique_zh":"电化学法","test_object_zh":"污水","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_zh":"溶解氧浓度"},{"_id":"6a7d78cb0636ba417e41a2b0","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr","parameters":[{"name":"Zakres","range":"(10 – 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (10 – 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (10 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (10 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Chemical oxygen demand - COD-Cr","parameters_en":[{"name":"Range","range":"(10 – 10000) mg/l O2"}],"search_en":"Wastewater Chemical oxygen demand - COD-Cr Spectrophotometric method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(10 – 10000) mg/l O2"}],"search_zh":"污水 化学需氧量（COD-Cr） 分光光度法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a7d78cb0636ba417e41a2b1","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Gleba","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-R-04031:1997","norm_bases":["PN-R-04031:1997"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Pobieranie próbek do badań chemicznych i fizycznych PN-R-04031:1997 Gleba Pobieranie probek do badan chemicznych i fizycznych PN-R-04031:1997","categories":["environment"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Sampling for chemical and physical testing","search_en":"Soil Sampling for chemical and physical testing Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-R-04031:1997","test_object_en":"Soil","methodology_zh":"化学与物理检测用样品采集","search_zh":"土壤 化学与物理检测用样品采集 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów PN-R-04031:1997","test_object_zh":"土壤","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów"},{"_id":"6a7d78cb0636ba417e41a2b2","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Gleba","methodology":"pH - w H2O","parameters":[{"name":"Zakres","range":"3,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH - w H2O\nZakres 3,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba pH - w H2O\nZakres 3,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Gleba pH - w H2O\nZakres 3,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"pH - in H2O","parameters_en":[{"name":"Range","range":"3,0 – 10,0"}],"search_en":"Soil pH - in H2O Potentiometric method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"3,0 – 10,0"}],"search_zh":"土壤 pH - 于 H2O 中 电位法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"土壤","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_zh":"pH - 于 H2O 中"},{"_id":"6a7d78cb0636ba417e41a2b3","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"P N-EN ISO 5667-13:2011","norm_bases":["P N-EN ISO 5667-13:2011"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Pobieranie próbek do badań chemicznych i fizycznych P N-EN ISO 5667-13:2011 Osady sciekowe Pobieranie probek do badan chemicznych i fizycznych P N-EN ISO 5667-13:2011","categories":["water"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Sampling for chemical and physical testing","search_en":"Sewage sludge Sampling for chemical and physical testing Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów P N-EN ISO 5667-13:2011","test_object_en":"Sewage sludge","methodology_zh":"化学与物理检测用样品采集","search_zh":"污泥 化学与物理检测用样品采集 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów P N-EN ISO 5667-13:2011","test_object_zh":"污泥","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów"},{"_id":"6a7d78cb0636ba417e41a2b4","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"pH, pH - w H2O","parameters":[{"name":"Zakres","range":"3,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH, pH - w H2O\nZakres 3,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe pH, pH - w H2O\nZakres 3,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Osady sciekowe pH, pH - w H2O\nZakres 3,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"pH, pH - in H2O","parameters_en":[{"name":"Range","range":"3,0 – 10,0"}],"search_en":"Sewage sludge pH, pH - in H2O Potentiometric method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"3,0 – 10,0"}],"search_zh":"污泥 电位法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"污泥","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów"},{"_id":"6a7d78cb0636ba417e41a2b5","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Sucha pozostałość / zawartość wody","parameters":[{"name":"Zakres","range":"(5,0 – 995,0) g/kg"},{"name":"Zakres","range":"(0,5 – 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość / zawartość wody\nZakres:\nZakres (5,0 – 995,0) g/kg\nZakres (0,5 – 99,5) %\nMetoda wagowa","reference":"PN-EN 12880:2004","norm_bases":["PN-EN 12880:2004"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Sucha pozostałość / zawartość wody\nZakres:\nZakres (5,0 – 995,0) g/kg\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 12880:2004 Osady sciekowe Sucha pozostalosc / zawartosc wody\nZakres:\nZakres (5,0 – 995,0) g/kg\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 12880:2004","categories":["water"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Dry residue / water content","parameters_en":[{"name":"Range","range":"(5,0 – 995,0) g/kg"},{"name":"Range","range":"(0,5 – 99,5) %"}],"search_en":"Sewage sludge Dry residue / water content Gravimetric method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range Range PN-EN 12880:2004","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(5,0 – 995,0) g/kg"},{"name":"范围","range":"(0,5 – 99,5) %"}],"search_zh":"污泥 干残渣/水分含量 重量法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 范围 PN-EN 12880:2004","technique_zh":"重量法","test_object_zh":"污泥","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_zh":"干残渣/水分含量"},{"_id":"6a7d78cb0636ba417e41a2b6","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Strata przy prażeniu suchej masy","parameters":[{"name":"Zakres","range":"(10,0 – 90,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Strata przy prażeniu suchej masy\nZakres (10,0 – 90,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Strata przy prażeniu suchej masy\nZakres (10,0 – 90,0) %\nMetoda wagowa PN-EN 15935:2022-01 Osady sciekowe Strata przy prazeniu suchej masy\nZakres (10,0 – 90,0) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["water"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Loss on ignition of dry matter","parameters_en":[{"name":"Range","range":"(10,0 – 90,0) %"}],"search_en":"Sewage sludge Loss on ignition of dry matter Gravimetric method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range PN-EN 15935:2022-01","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(10,0 – 90,0) %"}],"search_zh":"污泥 重量法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 PN-EN 15935:2022-01","technique_zh":"重量法","test_object_zh":"污泥","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów"},{"_id":"6a7d78cb0636ba417e41a2b7","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Stężenie azotu ogólnego Kjeldahla","parameters":[{"name":"Zakres","range":"(10 – 100) g/kg"},{"name":"Zakres","range":"(1,0 – 10) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu ogólnego Kjeldahla\nZakres:\nZakres (10 – 100) g/kg\nZakres (1,0 – 10) %\nMetoda miareczkowa","reference":"PN-EN 13342:2002","norm_bases":["PN-EN 13342:2002"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Stężenie azotu ogólnego Kjeldahla\nZakres:\nZakres (10 – 100) g/kg\nZakres (1,0 – 10) %\nMetoda miareczkowa PN-EN 13342:2002 Osady sciekowe Stezenie azotu ogolnego Kjeldahla\nZakres:\nZakres (10 – 100) g/kg\nZakres (1,0 – 10) %\nMetoda miareczkowa PN-EN 13342:2002","categories":["water"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Total Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(10 – 100) g/kg"},{"name":"Range","range":"(1,0 – 10) %"}],"search_en":"Sewage sludge Total Kjeldahl nitrogen concentration Titrimetric method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range Range PN-EN 13342:2002","technique_en":"Titrimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(10 – 100) g/kg"},{"name":"范围","range":"(1,0 – 10) %"}],"search_zh":"污泥 凯氏总氮浓度 滴定法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 范围 PN-EN 13342:2002","technique_zh":"滴定法","test_object_zh":"污泥","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_zh":"凯氏总氮浓度"},{"_id":"6a7d78cb0636ba417e41a2b8","lab_id":"69ad52a3de79e566650fb580","country":"PL","accr_number":"AB 1084","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość azotu amonowego","parameters":[{"name":"Zakres","range":"(0,01 – 3,00) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu amonowego\nZakres (0,01 – 3,00) %\nMetoda miareczkowa","reference":"PN-ISO 5664:2002 | PN-EN 14671:2007","norm_bases":["PN-ISO 5664:2002","PN-EN 14671:2007"],"lab_section":"Laboratorium; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość azotu amonowego\nZakres (0,01 – 3,00) %\nMetoda miareczkowa PN-ISO 5664:2002 | PN-EN 14671:2007 Osady sciekowe Zawartosc azotu amonowego\nZakres (0,01 – 3,00) %\nMetoda miareczkowa PN-ISO 5664:2002 | PN-EN 14671:2007","categories":["water"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_en":"Ammonium nitrogen content","parameters_en":[{"name":"Range","range":"(0,01 – 3,00) %"}],"search_en":"Sewage sludge Ammonium nitrogen content Titrimetric method Laboratory; Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów Range PN-ISO 5664:2002 | PN-EN 14671:2007","technique_en":"Titrimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,01 – 3,00) %"}],"search_zh":"污泥 氨氮含量 滴定法 实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów 范围 PN-ISO 5664:2002 | PN-EN 14671:2007","technique_zh":"滴定法","test_object_zh":"污泥","lab_section_zh":"实验室；Rojów, ul. Krotoszyńska 4, 63-500 Ostrzeszów","methodology_zh":"氨氮含量"}],"has_pdf":true}