{"lab":{"_id":"69ad52a3de79e566650fb578","accr_number":"AB 1079","country":"PL","accr_body":"PCA","address":"ul. Elizy Orzeszkowej 1, 76-200 Słupsk, LABORATORIUM BADANIA WODY I ŚCIEKÓW, ul. Sportowa 73","categories":["water","microbiology"],"city":"Słupsk","imported_at":"2026-03-08T10:42:43.265Z","methods_count":48,"name":"„WODOCIĄGI SŁUPSK” Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1079.pdf"],"scope_summary":"","search_text":"„wodociągi słupsk” sp. z o.o. ul. elizy orzeszkowej 1, 76-200 słupsk, laboratorium badania wody i ścieków, ul. sportowa 73 water other pharma electronics microbiology automotive","status":"active","updated_at":"2026-03-08T14:50:15.459Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T07:56:39.474Z","parse_date":"2026-08-13T07:56:39.474Z","parse_source":"agent-claude-code","email_confidence":"high","email_mx":true,"email_source":"https://www.wodociagi.slupsk.pl/laboratorium/","fields_of_testing":[{"codes":"C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of drinking water, sewage"},{"codes":"C/28","pl":"Badania chemiczne wody","en":"Chemical tests of water"},{"codes":"K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody do spożycia przez ludzi","en":"Microbiological tests and sampling of drinking water"},{"codes":"N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of drinking water, sewage"},{"codes":"N/28; N/32; N/43","pl":"Badania właściwości fizycznych wody, osadów, nawozów","en":"Tests of physical properties of water, sediments, fertilizers"},{"codes":"P/43","pl":"Pobieranie próbek nawozów","en":"Sampling of fertilizers"}],"issue":{"no":"18","date":"08.05.2026"},"map_coord":[54.475737,17.030976],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM BADANIA WODY I ŚCIEKÓW","address":"ul. Sportowa 73","city":null,"postal":null},{"name":"Laboratorium Badania Ścieków","address":"ul. Sportowa 73, 76-200 Słupsk","city":"Słupsk","postal":"76-200"},{"name":"Laboratorium Badania Wody","address":"ul. Bohaterów Westerplatte 54B, 76-200 Słupsk","city":"Słupsk","postal":"76-200"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/c4bb87107426f60209f6ed149169e57e/AB%201079.pdf","has_en":true,"category_counts":{"water":45,"microbiology":4,"other":2},"category_scores":{"water":39.71,"microbiology":0.31,"other":0.08},"has_zh":true,"lab_locations_zh":[{"name":"LABORATORIUM BADANIA WODY I ŚCIEKÓW","address":"ul. Sportowa 73","city":null,"postal":null},{"name":"废水检测实验室","address":"ul. Sportowa 73, 76-200 Słupsk","city":"Słupsk","postal":"76-200"},{"name":"水检测实验室","address":"ul. Bohaterów Westerplatte 54B, 76-200 Słupsk","city":"Słupsk","postal":"76-200"}]},"methods":[{"_id":"6a7d78b70636ba417e41a11f","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method Wastewater Testing Laboratory PN-ISO 5667-10:2021-11","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 废水检测实验室 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"污水","lab_section_zh":"废水检测实验室"},{"_id":"6a7d78b70636ba417e41a120","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,50 – 300) mg/l"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,50 – 300) mg/l\nMetoda miareczkowania potencjometrycznego","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (0,50 – 300) mg/l\nMetoda miareczkowania potencjometrycznego PN-ISO 5664:2002 Scieki Stezenie azotu amonowego\nZakres (0,50 – 300) mg/l\nMetoda miareczkowania potencjometrycznego PN-ISO 5664:2002","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,50 – 300) mg/l"}],"search_en":"Wastewater Ammonium nitrogen concentration Potentiometric titration method Wastewater Testing Laboratory Range PN-ISO 5664:2002","technique_en":"Potentiometric titration method","test_object_en":"Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,50 – 300) mg/l"}],"search_zh":"污水 氨氮浓度 电位滴定法 废水检测实验室 范围 PN-ISO 5664:2002","technique_zh":"电位滴定法","test_object_zh":"污水","lab_section_zh":"废水检测实验室"},{"_id":"6a7d78b70636ba417e41a121","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki, Woda pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Wastewater, Water pH Potentiometric method Wastewater Testing Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Wastewater, Water","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"废水、水 pH 值 电位法 废水检测实验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"废水、水","lab_section_zh":"废水检测实验室"},{"_id":"6a7d78b70636ba417e41a122","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 3000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 3000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Zawiesiny ogólne\nZakres (2,0 – 3000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki, Woda Zawiesiny ogolne\nZakres (2,0 – 3000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 3000) mg/l"}],"search_en":"Wastewater, Water Total suspended solids (TSS) Gravimetric method Wastewater Testing Laboratory Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Wastewater, Water","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 3000) mg/l"}],"search_zh":"废水、水 总悬浮物 重量法 废水检测实验室 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"废水、水","lab_section_zh":"废水检测实验室"},{"_id":"6a7d78b70636ba417e41a123","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(3 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki, Woda Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(3 – 6000) mg/l O2"}],"search_en":"Wastewater, Water Biochemical oxygen demand Electrochemical method Wastewater Testing Laboratory BOD5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Wastewater, Water","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(3 – 6000) mg/l O2"}],"search_zh":"废水、水 生化需氧量 电化学法 废水检测实验室 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"废水、水","lab_section_zh":"废水检测实验室"},{"_id":"6a7d78b70636ba417e41a124","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(0,5 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Scieki, Woda Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(0,5 – 6,0) mg/l O2"}],"search_en":"Wastewater, Water Biochemical oxygen demand Electrochemical method Wastewater Testing Laboratory BOD5 Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Wastewater, Water","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(0,5 – 6,0) mg/l O2"}],"search_zh":"废水、水 生化需氧量 电化学法 废水检测实验室 BZT5（BOD5） 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"废水、水","lab_section_zh":"废水检测实验室"},{"_id":"6a7d78b70636ba417e41a125","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Chemiczne zapotrzebowanie tlenu","parameters":[{"name":"ChZT-Cr"},{"name":"Zakres","range":"(5,00 – 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (5,00 – 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (5,00 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki, Woda Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (5,00 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Chemical oxygen demand","parameters_en":[{"name":"COD-Cr"},{"name":"Range","range":"(5,00 – 10000) mg/l O2"}],"search_en":"Wastewater, Water Chemical oxygen demand Spectrophotometric method Wastewater Testing Laboratory COD-Cr Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, Water","parameters_zh":[{"name":"化学需氧量（COD-Cr）"},{"name":"范围","range":"(5,00 – 10000) mg/l O2"}],"search_zh":"废水、水 化学需氧量（COD） 分光光度法 废水检测实验室 化学需氧量（COD-Cr） 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","methodology_zh":"化学需氧量（COD）","test_object_zh":"废水、水","lab_section_zh":"废水检测实验室"},{"_id":"6a7d78b70636ba417e41a126","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,10 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PB-PBŚ-06 wydanie 3 z dnia 25.02.2009 r. | na podstawie metody Hach Lange Nr 8038","norm_bases":["PB-PBŚ-06 wydanie 3 z dnia 25.02.2009 r.","na podstawie metody Hach Lange Nr 8038"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Stężenie azotu amonowego\nZakres (0,10 – 100) mg/l\nMetoda spektrofotometryczna PB-PBŚ-06 wydanie 3 z dnia 25.02.2009 r. | na podstawie metody Hach Lange Nr 8038 Scieki, Woda Stezenie azotu amonowego\nZakres (0,10 – 100) mg/l\nMetoda spektrofotometryczna PB-PBS-06 wydanie 3 z dnia 25.02.2009 r. | na podstawie metody Hach Lange Nr 8038","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/l"}],"search_en":"Wastewater, Water Ammonium nitrogen concentration Spectrophotometric method Wastewater Testing Laboratory Range PB-PBŚ-06 wydanie 3 z dnia 25.02.2009 r. | na podstawie metody Hach Lange Nr 8038","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, Water","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/l"}],"search_zh":"废水、水 氨氮浓度 分光光度法 废水检测实验室 范围 PB-PBŚ-06 wydanie 3 z dnia 25.02.2009 r. | na podstawie metody Hach Lange Nr 8038","technique_zh":"分光光度法","test_object_zh":"废水、水","lab_section_zh":"废水检测实验室"},{"_id":"6a7d78b70636ba417e41a127","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,50 – 27,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,50 – 27,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-PBŚ-01 wydanie 2 z dnia 25.02.2009 r. | na podstawie testu kuwetowego Hach Lange Nr LCK 339","norm_bases":["PB-PBŚ-01 wydanie 2 z dnia 25.02.2009 r.","na podstawie testu kuwetowego Hach Lange Nr LCK 339"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Stężenie azotu azotanowego\nZakres (0,50 – 27,0) mg/l\nMetoda spektrofotometryczna PB-PBŚ-01 wydanie 2 z dnia 25.02.2009 r. | na podstawie testu kuwetowego Hach Lange Nr LCK 339 Scieki, Woda Stezenie azotu azotanowego\nZakres (0,50 – 27,0) mg/l\nMetoda spektrofotometryczna PB-PBS-01 wydanie 2 z dnia 25.02.2009 r. | na podstawie testu kuwetowego Hach Lange Nr LCK 339","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,50 – 27,0) mg/l"}],"search_en":"Wastewater, Water Nitrate nitrogen concentration Spectrophotometric method Wastewater Testing Laboratory Range PB-PBŚ-01 wydanie 2 z dnia 25.02.2009 r. | na podstawie testu kuwetowego Hach Lange Nr LCK 339","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, Water","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,50 – 27,0) mg/l"}],"search_zh":"废水、水 硝态氮浓度 分光光度法 废水检测实验室 范围 PB-PBŚ-01 wydanie 2 z dnia 25.02.2009 r. | na podstawie testu kuwetowego Hach Lange Nr LCK 339","technique_zh":"分光光度法","test_object_zh":"废水、水","lab_section_zh":"废水检测实验室"},{"_id":"6a7d78b70636ba417e41a128","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,50 – 27,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,50 – 27,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Stężenie azotu azotanowego\nZakres (0,50 – 27,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Scieki, Woda Stezenie azotu azotanowego\nZakres (0,50 – 27,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,50 – 27,0) mg/l"}],"search_en":"Wastewater, Water Nitrate nitrogen concentration Spectrophotometric method Wastewater Testing Laboratory Range PN-82/C-04576.08","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, Water","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,50 – 27,0) mg/l"}],"search_zh":"废水、水 硝态氮浓度 分光光度法 废水检测实验室 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"废水、水","lab_section_zh":"废水检测实验室"},{"_id":"6a7d78b70636ba417e41a129","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,02 – 1,2) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,02 – 1,2) mg/l\nMetoda spektrofotometryczna","reference":"PB-PBŚ-03 wydanie 2 z dnia 25.02.2009 r. | na podstawie testu kuwetowego Hach Lange Nr LCK 341","norm_bases":["PB-PBŚ-03 wydanie 2 z dnia 25.02.2009 r.","na podstawie testu kuwetowego Hach Lange Nr LCK 341"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Stężenie azotu azotynowego\nZakres (0,02 – 1,2) mg/l\nMetoda spektrofotometryczna PB-PBŚ-03 wydanie 2 z dnia 25.02.2009 r. | na podstawie testu kuwetowego Hach Lange Nr LCK 341 Scieki, Woda Stezenie azotu azotynowego\nZakres (0,02 – 1,2) mg/l\nMetoda spektrofotometryczna PB-PBS-03 wydanie 2 z dnia 25.02.2009 r. | na podstawie testu kuwetowego Hach Lange Nr LCK 341","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,02 – 1,2) mg/l"}],"search_en":"Wastewater, Water Nitrite nitrogen concentration Spectrophotometric method Wastewater Testing Laboratory Range PB-PBŚ-03 wydanie 2 z dnia 25.02.2009 r. | na podstawie testu kuwetowego Hach Lange Nr LCK 341","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, Water","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 1,2) mg/l"}],"search_zh":"废水、水 亚硝态氮浓度 分光光度法 废水检测实验室 范围 PB-PBŚ-03 wydanie 2 z dnia 25.02.2009 r. | na podstawie testu kuwetowego Hach Lange Nr LCK 341","technique_zh":"分光光度法","test_object_zh":"废水、水","lab_section_zh":"废水检测实验室"},{"_id":"6a7d78b70636ba417e41a12a","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,02 – 1,20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,02 – 1,20) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Stężenie azotu azotynowego\nZakres (0,02 – 1,20) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Scieki, Woda Stezenie azotu azotynowego\nZakres (0,02 – 1,20) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,02 – 1,20) mg/l"}],"search_en":"Wastewater, Water Nitrite nitrogen concentration Spectrophotometric method Wastewater Testing Laboratory Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, Water","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 1,20) mg/l"}],"search_zh":"废水、水 亚硝态氮浓度 分光光度法 废水检测实验室 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"废水、水","lab_section_zh":"废水检测实验室"},{"_id":"6a7d78b70636ba417e41a12b","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(1,00 – 1000) mg/l"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (1,00 – 1000) mg/l\nMetoda miareczkowania potencjometrycznego","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Stężenie azotu Kjeldahla\nZakres (1,00 – 1000) mg/l\nMetoda miareczkowania potencjometrycznego PN-EN 25663:2001 Scieki, Woda Stezenie azotu Kjeldahla\nZakres (1,00 – 1000) mg/l\nMetoda miareczkowania potencjometrycznego PN-EN 25663:2001","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,00 – 1000) mg/l"}],"search_en":"Wastewater, Water Kjeldahl nitrogen concentration Potentiometric titration method Wastewater Testing Laboratory Range PN-EN 25663:2001","technique_en":"Potentiometric titration method","test_object_en":"Wastewater, Water","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(1,00 – 1000) mg/l"}],"search_zh":"废水、水 凯氏氮浓度 电位滴定法 废水检测实验室 范围 PN-EN 25663:2001","technique_zh":"电位滴定法","test_object_zh":"废水、水","lab_section_zh":"废水检测实验室"},{"_id":"6a7d78b70636ba417e41a12c","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-PBŚ-04 wydanie 3 z dnia 26.04.2018 r.","norm_bases":["PB-PBŚ-04 wydanie 3 z dnia 26.04.2018 r."],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Stężenie azotu ogólnego (z obliczeń) PB-PBŚ-04 wydanie 3 z dnia 26.04.2018 r. Scieki, Woda Stezenie azotu ogolnego (z obliczen) PB-PBS-04 wydanie 3 z dnia 26.04.2018 r.","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Wastewater, Water Total nitrogen concentration (calculated) Wastewater Testing Laboratory PB-PBŚ-04 wydanie 3 z dnia 26.04.2018 r.","test_object_en":"Wastewater, Water","methodology_zh":"总氮浓度（计算值）","search_zh":"废水、水 总氮浓度（计算值） 废水检测实验室 PB-PBŚ-04 wydanie 3 z dnia 26.04.2018 r.","test_object_zh":"废水、水","lab_section_zh":"废水检测实验室"},{"_id":"6a7d78b70636ba417e41a12d","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,05 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,05 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PB-PBŚ-02 wydanie 3 z dnia 30.05.2016 r. | na podstawie testu kuwetowego Hach Lange Nr LCK 348, LCK 349, LCK 350","norm_bases":["PB-PBŚ-02 wydanie 3 z dnia 30.05.2016 r.","na podstawie testu kuwetowego Hach Lange Nr LCK 348, LCK 349, LCK 350"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Stężenie fosforu ogólnego\nZakres (0,05 – 100) mg/l\nMetoda spektrofotometryczna PB-PBŚ-02 wydanie 3 z dnia 30.05.2016 r. | na podstawie testu kuwetowego Hach Lange Nr LCK 348, LCK 349, LCK 350 Scieki, Woda Stezenie fosforu ogolnego\nZakres (0,05 – 100) mg/l\nMetoda spektrofotometryczna PB-PBS-02 wydanie 3 z dnia 30.05.2016 r. | na podstawie testu kuwetowego Hach Lange Nr LCK 348, LCK 349, LCK 350","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,05 – 100) mg/l"}],"search_en":"Wastewater, Water Total phosphorus concentration Spectrophotometric method Wastewater Testing Laboratory Range PB-PBŚ-02 wydanie 3 z dnia 30.05.2016 r. | na podstawie testu kuwetowego Hach Lange Nr LCK 348, LCK 349, LCK 350","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, Water","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 100) mg/l"}],"search_zh":"废水、水 总磷浓度 分光光度法 废水检测实验室 范围 PB-PBŚ-02 wydanie 3 z dnia 30.05.2016 r. | na podstawie testu kuwetowego Hach Lange Nr LCK 348, LCK 349, LCK 350","technique_zh":"分光光度法","test_object_zh":"废水、水","lab_section_zh":"废水检测实验室"},{"_id":"6a7d78b70636ba417e41a12e","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,00 – 10 000) mg/l"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,00 – 10 000) mg/l\nMetoda miareczkowania potencjometrycznego","reference":"PB-PBŚ-09 wydanie 1 z dnia 25.02.2010 r.","norm_bases":["PB-PBŚ-09 wydanie 1 z dnia 25.02.2010 r."],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Stężenie chlorków\nZakres (5,00 – 10 000) mg/l\nMetoda miareczkowania potencjometrycznego PB-PBŚ-09 wydanie 1 z dnia 25.02.2010 r. Scieki, Woda Stezenie chlorkow\nZakres (5,00 – 10 000) mg/l\nMetoda miareczkowania potencjometrycznego PB-PBS-09 wydanie 1 z dnia 25.02.2010 r.","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,00 – 10 000) mg/l"}],"search_en":"Wastewater, Water Chloride concentration Potentiometric titration method Wastewater Testing Laboratory Range PB-PBŚ-09 wydanie 1 z dnia 25.02.2010 r.","technique_en":"Potentiometric titration method","test_object_en":"Wastewater, Water","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,00 – 10 000) mg/l"}],"search_zh":"废水、水 氯化物浓度 电位滴定法 废水检测实验室 范围 PB-PBŚ-09 wydanie 1 z dnia 25.02.2010 r.","technique_zh":"电位滴定法","test_object_zh":"废水、水","lab_section_zh":"废水检测实验室"},{"_id":"6a7d78b70636ba417e41a12f","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(5,0 – 300) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczanów\nZakres (5,0 – 300) mg/l\nMetoda spektrofotometryczna","reference":"PB-PBŚ-08 wydanie 2 z dnia 06.02.2017 r. | na podstawie metody Hach Lange Nr 8051","norm_bases":["PB-PBŚ-08 wydanie 2 z dnia 06.02.2017 r.","na podstawie metody Hach Lange Nr 8051"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Stężenie siarczanów\nZakres (5,0 – 300) mg/l\nMetoda spektrofotometryczna PB-PBŚ-08 wydanie 2 z dnia 06.02.2017 r. | na podstawie metody Hach Lange Nr 8051 Scieki, Woda Stezenie siarczanow\nZakres (5,0 – 300) mg/l\nMetoda spektrofotometryczna PB-PBS-08 wydanie 2 z dnia 06.02.2017 r. | na podstawie metody Hach Lange Nr 8051","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(5,0 – 300) mg/l"}],"search_en":"Wastewater, Water Sulfate concentration Spectrophotometric method Wastewater Testing Laboratory Range PB-PBŚ-08 wydanie 2 z dnia 06.02.2017 r. | na podstawie metody Hach Lange Nr 8051","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, Water","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 300) mg/l"}],"search_zh":"废水、水 硫酸盐浓度 分光光度法 废水检测实验室 范围 PB-PBŚ-08 wydanie 2 z dnia 06.02.2017 r. | na podstawie metody Hach Lange Nr 8051","technique_zh":"分光光度法","test_object_zh":"废水、水","lab_section_zh":"废水检测实验室"},{"_id":"6a7d78b70636ba417e41a130","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,0005 – 1,0) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,0005 – 1,0) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB-PBŚ-10 wydanie 1 z dnia 10.01.2011 r.","norm_bases":["PB-PBŚ-10 wydanie 1 z dnia 10.01.2011 r."],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Stężenie rtęci\nZakres (0,0005 – 1,0) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB-PBŚ-10 wydanie 1 z dnia 10.01.2011 r. Scieki, Woda Stezenie rteci\nZakres (0,0005 – 1,0) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB-PBS-10 wydanie 1 z dnia 10.01.2011 r.","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,0005 – 1,0) mg/l"}],"search_en":"Wastewater, Water Mercury concentration Atomic absorption spectrometry with amalgamation technique Wastewater Testing Laboratory Range PB-PBŚ-10 wydanie 1 z dnia 10.01.2011 r.","technique_en":"Atomic absorption spectrometry with amalgamation technique","test_object_en":"Wastewater, Water","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,0005 – 1,0) mg/l"}],"search_zh":"废水、水 汞浓度 原子吸收光谱法（汞齐化技术） 废水检测实验室 范围 PB-PBŚ-10 wydanie 1 z dnia 10.01.2011 r.","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"废水、水","lab_section_zh":"废水检测实验室"},{"_id":"6a7d78b70636ba417e41a131","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Stężenie substancji ekstrahujących się eterem naftowym","parameters":[{"name":"Zakres","range":"(10,0 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym\nZakres (10,0 – 2000) mg/l\nMetoda wagowa","reference":"PB-PBŚ-11 wydanie 2 z dnia 26.02.2019 r.","norm_bases":["PB-PBŚ-11 wydanie 2 z dnia 26.02.2019 r."],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Stężenie substancji ekstrahujących się eterem naftowym\nZakres (10,0 – 2000) mg/l\nMetoda wagowa PB-PBŚ-11 wydanie 2 z dnia 26.02.2019 r. Scieki, Woda Stezenie substancji ekstrahujacych sie eterem naftowym\nZakres (10,0 – 2000) mg/l\nMetoda wagowa PB-PBS-11 wydanie 2 z dnia 26.02.2019 r.","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Concentration of substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(10,0 – 2000) mg/l"}],"search_en":"Wastewater, Water Concentration of substances extractable with petroleum ether Gravimetric method Wastewater Testing Laboratory Range PB-PBŚ-11 wydanie 2 z dnia 26.02.2019 r.","technique_en":"Gravimetric method","test_object_en":"Wastewater, Water","parameters_zh":[{"name":"范围","range":"(10,0 – 2000) mg/l"}],"search_zh":"废水、水 石油醚可萃取物浓度 重量法 废水检测实验室 范围 PB-PBŚ-11 wydanie 2 z dnia 26.02.2019 r.","technique_zh":"重量法","test_object_zh":"废水、水","methodology_zh":"石油醚可萃取物浓度","lab_section_zh":"废水检测实验室"},{"_id":"6a7d78b70636ba417e41a132","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Nawóz organiczny - kompost","methodology":"Pobieranie próbek do badań chemicznych, fizycznych, mikrobiologicznych i parazytologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych, mikrobiologicznych i parazytologicznych","reference":"PB-PBŚ-12 wydanie 1 z dnia 11.02.2026 r.","norm_bases":["PB-PBŚ-12 wydanie 1 z dnia 11.02.2026 r."],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawóz organiczny - kompost Pobieranie próbek do badań chemicznych, fizycznych, mikrobiologicznych i parazytologicznych PB-PBŚ-12 wydanie 1 z dnia 11.02.2026 r. Nawoz organiczny - kompost Pobieranie probek do badan chemicznych, fizycznych, mikrobiologicznych i parazytologicznych PB-PBS-12 wydanie 1 z dnia 11.02.2026 r.","categories":["microbiology"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Sampling for chemical, physical, microbiological and parasitological testing","search_en":"Organic fertiliser - compost Sampling for chemical, physical, microbiological and parasitological testing Wastewater Testing Laboratory PB-PBŚ-12 wydanie 1 z dnia 11.02.2026 r.","test_object_en":"Organic fertiliser - compost","lab_section_zh":"废水检测实验室","search_zh":"有机肥 － 堆肥 用于化学、物理、微生物与寄生虫学检验的采样 废水检测实验室 PB-PBŚ-12 wydanie 1 z dnia 11.02.2026 r.","methodology_zh":"用于化学、物理、微生物与寄生虫学检验的采样","test_object_zh":"有机肥 － 堆肥"},{"_id":"6a7d78b70636ba417e41a133","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Nawóz organiczny - kompost","methodology":"pH","parameters":[{"name":"Zakres","range":"6,0 – 9,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 6,0 – 9,0\nMetoda potencjometryczna","reference":"PN-Z-15011-3:2001","norm_bases":["PN-Z-15011-3:2001"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawóz organiczny - kompost pH\nZakres 6,0 – 9,0\nMetoda potencjometryczna PN-Z-15011-3:2001 Nawoz organiczny - kompost pH\nZakres 6,0 – 9,0\nMetoda potencjometryczna PN-Z-15011-3:2001","categories":["other"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"6,0 – 9,0"}],"search_en":"Organic fertiliser - compost pH Potentiometric method Wastewater Testing Laboratory Range PN-Z-15011-3:2001","technique_en":"Potentiometric method","test_object_en":"Organic fertiliser - compost","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"6,0 – 9,0"}],"search_zh":"有机肥 － 堆肥 pH 值 电位法 废水检测实验室 范围 PN-Z-15011-3:2001","technique_zh":"电位法","lab_section_zh":"废水检测实验室","test_object_zh":"有机肥 － 堆肥"},{"_id":"6a7d78b70636ba417e41a134","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Nawóz organiczny - kompost","methodology":"Sucha pozostałość / zawartość wody","parameters":[{"name":"Zakres","range":"(20,0 – 80,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość / zawartość wody\nZakres (20,0 – 80,0) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02 Metoda A","norm_bases":["PN-EN 15934:2013-02 Metoda A"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawóz organiczny - kompost Sucha pozostałość / zawartość wody\nZakres (20,0 – 80,0) %\nMetoda wagowa PN-EN 15934:2013-02 Metoda A Nawoz organiczny - kompost Sucha pozostalosc / zawartosc wody\nZakres (20,0 – 80,0) %\nMetoda wagowa PN-EN 15934:2013-02 Metoda A","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Dry residue / water content","parameters_en":[{"name":"Range","range":"(20,0 – 80,0) %"}],"search_en":"Organic fertiliser - compost Dry residue / water content Gravimetric method Wastewater Testing Laboratory Range PN-EN 15934:2013-02 Metoda A","technique_en":"Gravimetric method","test_object_en":"Organic fertiliser - compost","parameters_zh":[{"name":"范围","range":"(20,0 – 80,0) %"}],"search_zh":"有机肥 － 堆肥 干残渣/水分含量 重量法 废水检测实验室 范围 PN-EN 15934:2013-02 Metoda A","technique_zh":"重量法","lab_section_zh":"废水检测实验室","methodology_zh":"干残渣/水分含量","test_object_zh":"有机肥 － 堆肥"},{"_id":"6a7d78b70636ba417e41a135","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Nawóz organiczny - kompost","methodology":"Straty przy prażeniu suchej masy (LOI) / pozostałość po prażeniu","parameters":[{"name":"Zakres","range":"(30,0 – 80,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy (LOI) / pozostałość po prażeniu\nZakres (30,0 – 80,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawóz organiczny - kompost Straty przy prażeniu suchej masy (LOI) / pozostałość po prażeniu\nZakres (30,0 – 80,0) %\nMetoda wagowa PN-EN 15935:2022-01 Nawoz organiczny - kompost Straty przy prazeniu suchej masy (LOI) / pozostalosc po prazeniu\nZakres (30,0 – 80,0) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["other"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Loss on ignition of dry matter (LOI) / residue on ignition","parameters_en":[{"name":"Range","range":"(30,0 – 80,0) %"}],"search_en":"Organic fertiliser - compost Loss on ignition of dry matter (LOI) / residue on ignition Gravimetric method Wastewater Testing Laboratory Range PN-EN 15935:2022-01","technique_en":"Gravimetric method","test_object_en":"Organic fertiliser - compost","parameters_zh":[{"name":"范围","range":"(30,0 – 80,0) %"}],"search_zh":"有机肥 － 堆肥 干物质烧失量（LOI）/ 灼烧残渣 重量法 废水检测实验室 范围 PN-EN 15935:2022-01","technique_zh":"重量法","lab_section_zh":"废水检测实验室","methodology_zh":"干物质烧失量（LOI）/ 灼烧残渣","test_object_zh":"有机肥 － 堆肥"},{"_id":"6a7d78b70636ba417e41a136","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"pH – w H2O","parameters":[{"name":"Zakres","range":"6,0 – 9,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH – w H2O\nZakres 6,0 – 9,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe pH – w H2O\nZakres 6,0 – 9,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Osady sciekowe pH – w H2O\nZakres 6,0 – 9,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"pH – in H2O","parameters_en":[{"name":"Range","range":"6,0 – 9,0"}],"search_en":"Sewage sludge pH – in H2O Potentiometric method Wastewater Testing Laboratory Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"6,0 – 9,0"}],"search_zh":"污泥 pH — 于 H2O 中 电位法 废水检测实验室 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"污泥","lab_section_zh":"废水检测实验室","methodology_zh":"pH — 于 H2O 中"},{"_id":"6a7d78b70636ba417e41a137","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Sucha pozostałość / zawartość wody","parameters":[{"name":"Zakres","range":"(1,0 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość / zawartość wody\nZakres (1,0 – 99,0) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02 Metoda A","norm_bases":["PN-EN 15934:2013-02 Metoda A"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Sucha pozostałość / zawartość wody\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15934:2013-02 Metoda A Osady sciekowe Sucha pozostalosc / zawartosc wody\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15934:2013-02 Metoda A","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Dry residue / water content","parameters_en":[{"name":"Range","range":"(1,0 – 99,0) %"}],"search_en":"Sewage sludge Dry residue / water content Gravimetric method Wastewater Testing Laboratory Range PN-EN 15934:2013-02 Metoda A","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(1,0 – 99,0) %"}],"search_zh":"污泥 干残渣/水分含量 重量法 废水检测实验室 范围 PN-EN 15934:2013-02 Metoda A","technique_zh":"重量法","test_object_zh":"污泥","lab_section_zh":"废水检测实验室","methodology_zh":"干残渣/水分含量"},{"_id":"6a7d78b70636ba417e41a138","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Straty przy prażeniu suchej masy (LOI) / pozostałość po prażeniu","parameters":[{"name":"Zakres","range":"(1,0 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy (LOI) / pozostałość po prażeniu\nZakres (1,0 – 99,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Straty przy prażeniu suchej masy (LOI) / pozostałość po prażeniu\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15935:2022-01 Osady sciekowe Straty przy prazeniu suchej masy (LOI) / pozostalosc po prazeniu\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Loss on ignition of dry matter (LOI) / residue on ignition","parameters_en":[{"name":"Range","range":"(1,0 – 99,0) %"}],"search_en":"Sewage sludge Loss on ignition of dry matter (LOI) / residue on ignition Gravimetric method Wastewater Testing Laboratory Range PN-EN 15935:2022-01","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(1,0 – 99,0) %"}],"search_zh":"污泥 干物质烧失量（LOI）/ 灼烧残渣 重量法 废水检测实验室 范围 PN-EN 15935:2022-01","technique_zh":"重量法","test_object_zh":"污泥","lab_section_zh":"废水检测实验室","methodology_zh":"干物质烧失量（LOI）/ 灼烧残渣"},{"_id":"6a7d78b70636ba417e41a139","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Water intended for human consumption Sampling for chemical and physical testing Water Testing Laboratory PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 水检测实验室 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水","lab_section_zh":"水检测实验室"},{"_id":"6a7d78b70636ba417e41a13a","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6","categories":["water","microbiology"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Sampling for microbiological testing","search_en":"Water intended for human consumption Sampling for microbiological testing Water Testing Laboratory PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6","test_object_en":"Water intended for human consumption","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 水检测实验室 PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6","test_object_zh":"生活饮用水","lab_section_zh":"水检测实验室"},{"_id":"6a7d78b70636ba417e41a13b","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(2 – 70) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (2 – 70) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","norm_bases":["PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Barwa\nZakres (2 – 70) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C Woda do spozycia przez ludzi, Woda Barwa\nZakres (2 – 70) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(2 – 70) mg/l Pt"}],"search_en":"Water intended for human consumption, Water Colour Spectrophotometric method Water Testing Laboratory Range PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(2 – 70) mg/l Pt"}],"search_zh":"生活饮用水、水 色度 分光光度法 水检测实验室 范围 PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","technique_zh":"分光光度法","test_object_zh":"生活饮用水、水","lab_section_zh":"水检测实验室"},{"_id":"6a7d78b70636ba417e41a13c","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 – 40) mg/l Pt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa\nZakres (5 – 40) mg/l Pt\nMetoda wizualna","reference":"PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D","norm_bases":["PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Barwa\nZakres (5 – 40) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D Woda do spozycia przez ludzi, Woda Barwa\nZakres (5 – 40) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 – 40) mg/l Pt"}],"search_en":"Water intended for human consumption, Water Colour Visual method Water Testing Laboratory Range PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D","technique_en":"Visual method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 40) mg/l Pt"}],"search_zh":"生活饮用水、水 色度 目视法 水检测实验室 范围 PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D","technique_zh":"目视法","test_object_zh":"生活饮用水、水","lab_section_zh":"水检测实验室"},{"_id":"6a7d78b70636ba417e41a13d","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(5 – 2000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (5 – 2000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Przewodność elektryczna właściwa\nZakres (5 – 2000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi, Woda Przewodnosc elektryczna wlasciwa\nZakres (5 – 2000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(5 – 2000) μS/cm"}],"search_en":"Water intended for human consumption, Water Electrical conductivity Conductometric method Water Testing Laboratory Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(5 – 2000) μS/cm"}],"search_zh":"生活饮用水、水 电导率 电导法 水检测实验室 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"生活饮用水、水","lab_section_zh":"水检测实验室"},{"_id":"6a7d78b70636ba417e41a13e","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,1 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,1 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04576-4:1994","norm_bases":["PN-C-04576-4:1994"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Stężenie jonu amonowego\nZakres (0,1 – 2,0) mg/l\nMetoda spektrofotometryczna PN-C-04576-4:1994 Woda do spozycia przez ludzi, Woda Stezenie jonu amonowego\nZakres (0,1 – 2,0) mg/l\nMetoda spektrofotometryczna PN-C-04576-4:1994","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,1 – 2,0) mg/l"}],"search_en":"Water intended for human consumption, Water Ammonium ion concentration Spectrophotometric method Water Testing Laboratory Range PN-C-04576-4:1994","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,1 – 2,0) mg/l"}],"search_zh":"生活饮用水、水 铵离子浓度 分光光度法 水检测实验室 范围 PN-C-04576-4:1994","technique_zh":"分光光度法","test_object_zh":"生活饮用水、水","lab_section_zh":"水检测实验室"},{"_id":"6a7d78b70636ba417e41a13f","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,005 – 0,80) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,005 – 0,80) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Stężenie azotynów\nZakres (0,005 – 0,80) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda do spozycia przez ludzi, Woda Stezenie azotynow\nZakres (0,005 – 0,80) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,005 – 0,80) mg/l"}],"search_en":"Water intended for human consumption, Water Nitrite concentration Spectrophotometric method Water Testing Laboratory Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,005 – 0,80) mg/l"}],"search_zh":"生活饮用水、水 亚硝酸盐浓度 分光光度法 水检测实验室 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"生活饮用水、水","lab_section_zh":"水检测实验室"},{"_id":"6a7d78b70636ba417e41a140","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(30 – 5000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (30 – 5000) μg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Stężenie żelaza\nZakres (30 – 5000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda do spozycia przez ludzi, Woda Stezenie zelaza\nZakres (30 – 5000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(30 – 5000) μg/l"}],"search_en":"Water intended for human consumption, Water Iron concentration Spectrophotometric method Water Testing Laboratory Range PN-ISO 6332:2001+Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(30 – 5000) μg/l"}],"search_zh":"生活饮用水、水 铁浓度 分光光度法 水检测实验室 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"生活饮用水、水","lab_section_zh":"水检测实验室"},{"_id":"6a7d78b70636ba417e41a141","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,20 – 40) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,20 – 40) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Mętność\nZakres (0,20 – 40) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda do spozycia przez ludzi, Woda Metnosc\nZakres (0,20 – 40) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,20 – 40) NTU"}],"search_en":"Water intended for human consumption, Water Turbidity Nephelometric method Water Testing Laboratory Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 – 40) NTU"}],"search_zh":"生活饮用水、水 浊度 浊度法（散射法） 水检测实验室 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"生活饮用水、水","lab_section_zh":"水检测实验室"},{"_id":"6a7d78b70636ba417e41a142","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,10 – 80,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,10 – 80,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Stężenie azotanów\nZakres (0,10 – 80,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda do spozycia przez ludzi, Woda Stezenie azotanow\nZakres (0,10 – 80,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(0,10 – 80,0) mg/l"}],"search_en":"Water intended for human consumption, Water Nitrate concentration Spectrophotometric method Water Testing Laboratory Range PN-82/C-04576.08","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 80,0) mg/l"}],"search_zh":"生活饮用水、水 硝酸盐浓度 分光光度法 水检测实验室 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"生活饮用水、水","lab_section_zh":"水检测实验室"},{"_id":"6a7d78b70636ba417e41a143","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(10 – 2000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (10 – 2000) μg/l\nMetoda spektrofotometryczna","reference":"PB-PBW-02 wydanie 3 z dnia 18.06.2012 r. | na podstawie metody Hach Lange Nr 8149","norm_bases":["PB-PBW-02 wydanie 3 z dnia 18.06.2012 r.","na podstawie metody Hach Lange Nr 8149"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Stężenie manganu\nZakres (10 – 2000) μg/l\nMetoda spektrofotometryczna PB-PBW-02 wydanie 3 z dnia 18.06.2012 r. | na podstawie metody Hach Lange Nr 8149 Woda do spozycia przez ludzi, Woda Stezenie manganu\nZakres (10 – 2000) μg/l\nMetoda spektrofotometryczna PB-PBW-02 wydanie 3 z dnia 18.06.2012 r. | na podstawie metody Hach Lange Nr 8149","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(10 – 2000) μg/l"}],"search_en":"Water intended for human consumption, Water Manganese concentration Spectrophotometric method Water Testing Laboratory Range PB-PBW-02 wydanie 3 z dnia 18.06.2012 r. | na podstawie metody Hach Lange Nr 8149","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(10 – 2000) μg/l"}],"search_zh":"生活饮用水、水 锰浓度 分光光度法 水检测实验室 范围 PB-PBW-02 wydanie 3 z dnia 18.06.2012 r. | na podstawie metody Hach Lange Nr 8149","technique_zh":"分光光度法","test_object_zh":"生活饮用水、水","lab_section_zh":"水检测实验室"},{"_id":"6a7d78b70636ba417e41a144","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda do spozycia przez ludzi, Woda pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 10,0"}],"search_en":"Water intended for human consumption, Water pH Potentiometric method Water Testing Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 10,0"}],"search_zh":"生活饮用水、水 pH 值 电位法 水检测实验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"生活饮用水、水","lab_section_zh":"水检测实验室"},{"_id":"6a7d78b70636ba417e41a145","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(5,0 – 300) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczanów\nZakres (5,0 – 300) mg/l\nMetoda spektrofotometryczna","reference":"PB-PBW-03 wydanie 4 z dnia 14.02.2017 r. | na podstawie metody Hach Lange Nr 8051","norm_bases":["PB-PBW-03 wydanie 4 z dnia 14.02.2017 r.","na podstawie metody Hach Lange Nr 8051"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Stężenie siarczanów\nZakres (5,0 – 300) mg/l\nMetoda spektrofotometryczna PB-PBW-03 wydanie 4 z dnia 14.02.2017 r. | na podstawie metody Hach Lange Nr 8051 Woda do spozycia przez ludzi, Woda Stezenie siarczanow\nZakres (5,0 – 300) mg/l\nMetoda spektrofotometryczna PB-PBW-03 wydanie 4 z dnia 14.02.2017 r. | na podstawie metody Hach Lange Nr 8051","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(5,0 – 300) mg/l"}],"search_en":"Water intended for human consumption, Water Sulfate concentration Spectrophotometric method Water Testing Laboratory Range PB-PBW-03 wydanie 4 z dnia 14.02.2017 r. | na podstawie metody Hach Lange Nr 8051","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 300) mg/l"}],"search_zh":"生活饮用水、水 硫酸盐浓度 分光光度法 水检测实验室 范围 PB-PBW-03 wydanie 4 z dnia 14.02.2017 r. | na podstawie metody Hach Lange Nr 8051","technique_zh":"分光光度法","test_object_zh":"生活饮用水、水","lab_section_zh":"水检测实验室"},{"_id":"6a7d78b70636ba417e41a146","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 400) mg/l\nMetoda miareczkowa","reference":"PB-PBW-07 wydanie 1 z dnia 01.03.2011 r.","norm_bases":["PB-PBW-07 wydanie 1 z dnia 01.03.2011 r."],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Stężenie chlorków\nZakres (5,0 – 400) mg/l\nMetoda miareczkowa PB-PBW-07 wydanie 1 z dnia 01.03.2011 r. Woda do spozycia przez ludzi, Woda Stezenie chlorkow\nZakres (5,0 – 400) mg/l\nMetoda miareczkowa PB-PBW-07 wydanie 1 z dnia 01.03.2011 r.","categories":["water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 400) mg/l"}],"search_en":"Water intended for human consumption, Water Chloride concentration Titrimetric method Water Testing Laboratory Range PB-PBW-07 wydanie 1 z dnia 01.03.2011 r.","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 400) mg/l"}],"search_zh":"生活饮用水、水 氯化物浓度 滴定法 水检测实验室 范围 PB-PBW-07 wydanie 1 z dnia 01.03.2011 r.","technique_zh":"滴定法","test_object_zh":"生活饮用水、水","lab_section_zh":"水检测实验室"},{"_id":"6a7d78b70636ba417e41a147","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Stężenie fluorków","parameters":[{"name":"Zakres","range":"(0,1 – 2,0) mg/l"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Stężenie fluorków\nZakres (0,1 – 2,0) mg/l\nMetoda potencjometryczna","reference":"PB-PBW-08 wydanie 3 z dnia 20.02.2019 r.","norm_bases":["PB-PBW-08 wydanie 3 z dnia 20.02.2019 r."],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Stężenie fluorków\nZakres (0,1 – 2,0) mg/l\nMetoda potencjometryczna PB-PBW-08 wydanie 3 z dnia 20.02.2019 r. Woda do spozycia przez ludzi, Woda Stezenie fluorkow\nZakres (0,1 – 2,0) mg/l\nMetoda potencjometryczna PB-PBW-08 wydanie 3 z dnia 20.02.2019 r.","categories":["water"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Fluoride concentration","parameters_en":[{"name":"Range","range":"(0,1 – 2,0) mg/l"}],"search_en":"Water intended for human consumption, Water Fluoride concentration Potentiometric method Water Testing Laboratory Range PB-PBW-08 wydanie 3 z dnia 20.02.2019 r.","technique_en":"Potentiometric method","test_object_en":"Water intended for human consumption, Water","parameters_zh":[{"name":"范围","range":"(0,1 – 2,0) mg/l"}],"search_zh":"生活饮用水、水 氟化物浓度 电位法 水检测实验室 范围 PB-PBW-08 wydanie 3 z dnia 20.02.2019 r.","technique_zh":"电位法","methodology_zh":"氟化物浓度","test_object_zh":"生活饮用水、水","lab_section_zh":"水检测实验室"},{"_id":"6a7d78b70636ba417e41a148","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,5 – 50) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,5 – 50) mg/l\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Indeks nadmanganianowy\nZakres (0,5 – 50) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda do spozycia przez ludzi, Woda Indeks nadmanganianowy\nZakres (0,5 – 50) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,5 – 50) mg/l"}],"search_en":"Water intended for human consumption, Water Permanganate index Titrimetric method Water Testing Laboratory Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,5 – 50) mg/l"}],"search_zh":"生活饮用水、水 高锰酸盐指数 滴定法 水检测实验室 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"生活饮用水、水","lab_section_zh":"水检测实验室"},{"_id":"6a7d78b70636ba417e41a149","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(5,0 – 500) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5,0 – 500) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5,0 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda do spozycia przez ludzi, Woda Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (5,0 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(5,0 – 500) mg/l CaCO3"}],"search_en":"Water intended for human consumption, Water Total content of calcium and magnesium (total hardness) Titrimetric method Water Testing Laboratory Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(5,0 – 500) mg/l CaCO3"}],"search_zh":"生活饮用水、水 钙与镁总量（总硬度） 滴定法 水检测实验室 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"生活饮用水、水","lab_section_zh":"水检测实验室"},{"_id":"6a7d78b70636ba417e41a14a","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Coliform bacteria count","search_en":"Water intended for human consumption Coliform bacteria count Membrane filtration method Water Testing Laboratory PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","methodology_zh":"大肠菌群计数","search_zh":"生活饮用水 大肠菌群计数 膜过滤法 水检测实验室 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水","lab_section_zh":"水检测实验室"},{"_id":"6a7d78b70636ba417e41a14b","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Escherichia coli count","search_en":"Water intended for human consumption Escherichia coli count Membrane filtration method Water Testing Laboratory PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 水检测实验室 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水","lab_section_zh":"水检测实验室"},{"_id":"6a7d78b70636ba417e41a14c","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 36 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 36 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Total viable count at 36 °C","search_en":"Water intended for human consumption Total viable count at 36 °C Plate method (pour plate) Water Testing Laboratory PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water intended for human consumption","methodology_zh":"36 °C 微生物总数","search_zh":"生活饮用水 36 °C 微生物总数 平板法（倾注培养） 水检测实验室 PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水","lab_section_zh":"水检测实验室"},{"_id":"6a7d78b70636ba417e41a14d","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 22 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Total viable count at 22 °C","search_en":"Water intended for human consumption Total viable count at 22 °C Plate method (pour plate) Water Testing Laboratory PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water intended for human consumption","methodology_zh":"22 °C 微生物总数","search_zh":"生活饮用水 22 °C 微生物总数 平板法（倾注培养） 水检测实验室 PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水","lab_section_zh":"水检测实验室"},{"_id":"6a7d78b70636ba417e41a14e","lab_id":"69ad52a3de79e566650fb578","country":"PL","accr_number":"AB 1079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Intestinal enterococci count","search_en":"Water intended for human consumption Intestinal enterococci count Membrane filtration method Water Testing Laboratory PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","methodology_zh":"粪肠球菌计数","search_zh":"生活饮用水 粪肠球菌计数 膜过滤法 水检测实验室 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"生活饮用水","lab_section_zh":"水检测实验室"}],"has_pdf":true}