{"lab":{"_id":"69ad52a3de79e566650fb574","accr_number":"AB 1072","country":"PL","accr_body":"PCA","address":"ZESPÓŁ MONITORINGU ŚRODOWISKA, ul. Pelplińska 19, 83-200 Starogard Gdański","categories":["water","environment"],"city":"Starogard Gdański","imported_at":"2026-03-08T10:42:43.265Z","methods_count":44,"name":"ZAKŁADY FARMACEUTYCZNE POLPHARMA S.A.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1072.pdf"],"scope_summary":"","search_text":"zakłady farmaceutyczne polpharma s.a. zespół monitoringu środowiska, ul. pelplińska 19, 83-200 starogard gdański water other materials pharma electronics food environment petro","status":"active","updated_at":"2026-03-08T14:50:15.226Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-14T12:51:07.275Z","parse_date":"2026-08-14T12:51:07.275Z","parse_source":"agent-claude-code","email_confidence":"low","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%201072,podmiot.html","needs_review":true,"review_reason":"e-mail niepewny (low) — zweryfikuj","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of water, drinking water, sewage"},{"codes":"C/33/P","pl":"Badania chemiczne i pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze)","en":"Chemical tests and sampling – working environment (harmful factors – air)"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe – hałas)","en":"Tests concerning environmental engineering (environmental and climatic) – workplace (harmful factors – noise)"},{"codes":"N/28/P; N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of water, drinking water, sewage"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze)","en":"Tests of physical properties and sampling – working environment (harmful factors – air)"}],"issue":{"no":"20","date":"07.05.2026"},"map_coord":[53.960968,18.538953],"map_geo":"nominatim-street","lab_locations":[{"name":"ZESPÓŁ MONITORINGU ŚRODOWISKA","address":"ul. Pelplińska 19","city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/14/6425983b656b0904eb3e9c2e18d833e7/AB%201072.pdf","has_en":true,"category_counts":{"water":35,"environment":9,"petro":1,"materials":1},"category_scores":{"water":26.63,"environment":1.76,"petro":0.02,"materials":0.02},"has_zh":true},"methods":[{"_id":"6a7f0f3b1995264369d8e382","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.3, 7.5, 7.6, 8.2, 9.4","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.3, 7.5, 7.6, 8.2, 9.4"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.3, 7.5, 7.6, 8.2, 9.4 Woda Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wylaczeniem pkt. 7.3, 7.5, 7.6, 8.2, 9.4","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water Sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.3, 7.5, 7.6, 8.2, 9.4","test_object_en":"Water","methodology_zh":"化学与物理检测用样品采集","search_zh":"水 化学与物理检测用样品采集 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.3, 7.5, 7.6, 8.2, 9.4","test_object_zh":"水"},{"_id":"6a7f0f3b1995264369d8e383","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Woda","methodology":"Temperatura pobranej próbki wody","parameters":[{"name":"Zakres","range":"(0,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura pobranej próbki wody\nZakres (0,0 – 50,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Temperatura pobranej próbki wody\nZakres (0,0 – 50,0) °C PN-77/C-04584 Woda Temperatura pobranej probki wody\nZakres (0,0 – 50,0) °C PN-77/C-04584","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature of the collected water sample","parameters_en":[{"name":"Range","range":"(0,0 – 50,0) °C"}],"search_en":"Water Temperature of the collected water sample Range PN-77/C-04584","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,0 – 50,0) °C"}],"search_zh":"水 所采水样的温度 范围 PN-77/C-04584","test_object_zh":"水","methodology_zh":"所采水样的温度"},{"_id":"6a7f0f3b1995264369d8e384","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Woda","methodology":"Indeks fenolowy","parameters":[{"name":"Zakres","range":"(0,002 – 0,100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Indeks fenolowy\nZakres (0,002 – 0,100) mg/l\nMetoda spektrofotometryczna","reference":"ON/IA/017/1 z dnia 09.10.2007 r. | na podstawie testu Merck Nr 1.00856","norm_bases":["ON/IA/017/1 z dnia 09.10.2007 r.","na podstawie testu Merck Nr 1.00856"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Indeks fenolowy\nZakres (0,002 – 0,100) mg/l\nMetoda spektrofotometryczna ON/IA/017/1 z dnia 09.10.2007 r. | na podstawie testu Merck Nr 1.00856 Woda Indeks fenolowy\nZakres (0,002 – 0,100) mg/l\nMetoda spektrofotometryczna ON/IA/017/1 z dnia 09.10.2007 r. | na podstawie testu Merck Nr 1.00856","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol index","parameters_en":[{"name":"Range","range":"(0,002 – 0,100) mg/l"}],"search_en":"Water Phenol index Spectrophotometric method Range ON/IA/017/1 z dnia 09.10.2007 r. | na podstawie testu Merck Nr 1.00856","technique_en":"Spectrophotometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,002 – 0,100) mg/l"}],"search_zh":"水 酚指数 分光光度法 范围 ON/IA/017/1 z dnia 09.10.2007 r. | na podstawie testu Merck Nr 1.00856","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"酚指数"},{"_id":"6a7f0f3b1995264369d8e385","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(0,005 – 5,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (0,005 – 5,00) mg/l\nMetoda spektrofotometryczna","reference":"ON/IA/020/1 z dnia 05.03.2008 r. | na podstawie testu Merck Nr 1.14761","norm_bases":["ON/IA/020/1 z dnia 05.03.2008 r.","na podstawie testu Merck Nr 1.14761"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie żelaza\nZakres (0,005 – 5,00) mg/l\nMetoda spektrofotometryczna ON/IA/020/1 z dnia 05.03.2008 r. | na podstawie testu Merck Nr 1.14761 Woda Stezenie zelaza\nZakres (0,005 – 5,00) mg/l\nMetoda spektrofotometryczna ON/IA/020/1 z dnia 05.03.2008 r. | na podstawie testu Merck Nr 1.14761","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(0,005 – 5,00) mg/l"}],"search_en":"Water Iron concentration Spectrophotometric method Range ON/IA/020/1 z dnia 05.03.2008 r. | na podstawie testu Merck Nr 1.14761","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(0,005 – 5,00) mg/l"}],"search_zh":"水 铁浓度 分光光度法 范围 ON/IA/020/1 z dnia 05.03.2008 r. | na podstawie testu Merck Nr 1.14761","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a7f0f3b1995264369d8e386","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,010 – 0,800) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie manganu\nZakres (0,010 – 0,800) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 metoda A","norm_bases":["PN-ISO 8288:2002 metoda A"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie manganu\nZakres (0,010 – 0,800) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A Woda Stezenie manganu\nZakres (0,010 – 0,800) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(0,010 – 0,800) mg/l"}],"search_en":"Water Manganese concentration Flame atomic absorption spectrometry (FAAS) Range PN-ISO 8288:2002 metoda A","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 0,800) mg/l"}],"search_zh":"水 锰浓度 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 8288:2002 metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水"},{"_id":"6a7f0f3b1995264369d8e387","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,10 – 1,0) µg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,10 – 1,0) µg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN ISO 12846:2012 + Ap1:2016-07 pkt. 6","norm_bases":["PN-EN ISO 12846:2012 + Ap1:2016-07 pkt. 6"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie rtęci\nZakres (0,10 – 1,0) µg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012 + Ap1:2016-07 pkt. 6 Woda Stezenie rteci\nZakres (0,10 – 1,0) µg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012 + Ap1:2016-07 pkt. 6","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,10 – 1,0) µg/l"}],"search_en":"Water Mercury concentration Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN ISO 12846:2012 + Ap1:2016-07 pkt. 6","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"Water","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 1,0) µg/l"}],"search_zh":"水 汞浓度 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN ISO 12846:2012 + Ap1:2016-07 pkt. 6","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"水"},{"_id":"6a7f0f3b1995264369d8e388","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667- 5:2017-10","norm_bases":["PN-ISO 5667- 5:2017-10"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667- 5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667- 5:2017-10","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667- 5:2017-10","test_object_en":"Water intended for human consumption","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 PN-ISO 5667- 5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a7f0f3b1995264369d8e389","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Temperatura pobranej próbki wody","parameters":[{"name":"Zakres","range":"(0,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura pobranej próbki wody\nZakres (0,0 – 50,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Temperatura pobranej próbki wody\nZakres (0,0 – 50,0) °C PN-77/C-04584 Woda do spozycia przez ludzi Temperatura pobranej probki wody\nZakres (0,0 – 50,0) °C PN-77/C-04584","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature of the collected water sample","parameters_en":[{"name":"Range","range":"(0,0 – 50,0) °C"}],"search_en":"Water intended for human consumption Temperature of the collected water sample Range PN-77/C-04584","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,0 – 50,0) °C"}],"search_zh":"生活饮用水 所采水样的温度 范围 PN-77/C-04584","test_object_zh":"生活饮用水","methodology_zh":"所采水样的温度"},{"_id":"6a7f0f3b1995264369d8e38a","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(0,005 – 1,000) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (0,005 – 1,000) mg/l\nMetoda spektrofotometryczna","reference":"ON/IA/020/1 z dnia 05.03.2008 r. | na podstawie testu Merck Nr 1.14761","norm_bases":["ON/IA/020/1 z dnia 05.03.2008 r.","na podstawie testu Merck Nr 1.14761"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie żelaza\nZakres (0,005 – 1,000) mg/l\nMetoda spektrofotometryczna ON/IA/020/1 z dnia 05.03.2008 r. | na podstawie testu Merck Nr 1.14761 Woda do spozycia przez ludzi Stezenie zelaza\nZakres (0,005 – 1,000) mg/l\nMetoda spektrofotometryczna ON/IA/020/1 z dnia 05.03.2008 r. | na podstawie testu Merck Nr 1.14761","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(0,005 – 1,000) mg/l"}],"search_en":"Water intended for human consumption Iron concentration Spectrophotometric method Range ON/IA/020/1 z dnia 05.03.2008 r. | na podstawie testu Merck Nr 1.14761","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(0,005 – 1,000) mg/l"}],"search_zh":"生活饮用水 铁浓度 分光光度法 范围 ON/IA/020/1 z dnia 05.03.2008 r. | na podstawie testu Merck Nr 1.14761","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a7f0f3b1995264369d8e38b","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(5 – 250) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczanów\nZakres (5 – 250) mg/l\nMetoda spektrofotometryczna","reference":"ON/IA/019/2 z dnia 07.04.2021 r. | na podstawie testu Merck Nr 1.14548","norm_bases":["ON/IA/019/2 z dnia 07.04.2021 r.","na podstawie testu Merck Nr 1.14548"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie siarczanów\nZakres (5 – 250) mg/l\nMetoda spektrofotometryczna ON/IA/019/2 z dnia 07.04.2021 r. | na podstawie testu Merck Nr 1.14548 Woda do spozycia przez ludzi Stezenie siarczanow\nZakres (5 – 250) mg/l\nMetoda spektrofotometryczna ON/IA/019/2 z dnia 07.04.2021 r. | na podstawie testu Merck Nr 1.14548","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(5 – 250) mg/l"}],"search_en":"Water intended for human consumption Sulfate concentration Spectrophotometric method Range ON/IA/019/2 z dnia 07.04.2021 r. | na podstawie testu Merck Nr 1.14548","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(5 – 250) mg/l"}],"search_zh":"生活饮用水 硫酸盐浓度 分光光度法 范围 ON/IA/019/2 z dnia 07.04.2021 r. | na podstawie testu Merck Nr 1.14548","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a7f0f3b1995264369d8e38c","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie azotu amonowego / jonu amonowego","parameters":[{"name":"Zakres","range":"(0,010 – 0,500) mg/l N-NH4"},{"name":"Zakres","range":"(0,013 – 0,644) mg/l NH4 +"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego / jonu amonowego\nZakres:\nZakres (0,010 – 0,500) mg/l N-NH4\nZakres (0,013 – 0,644) mg/l NH4 +\nMetoda spektrofotometryczna","reference":"ON/IA/014/3 z dnia 11.12.2012 r. | na podstawie testu Merck Nr 1.14752","norm_bases":["ON/IA/014/3 z dnia 11.12.2012 r.","na podstawie testu Merck Nr 1.14752"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie azotu amonowego / jonu amonowego\nZakres:\nZakres (0,010 – 0,500) mg/l N-NH4\nZakres (0,013 – 0,644) mg/l NH4 +\nMetoda spektrofotometryczna ON/IA/014/3 z dnia 11.12.2012 r. | na podstawie testu Merck Nr 1.14752 Woda do spozycia przez ludzi Stezenie azotu amonowego / jonu amonowego\nZakres:\nZakres (0,010 – 0,500) mg/l N-NH4\nZakres (0,013 – 0,644) mg/l NH4 +\nMetoda spektrofotometryczna ON/IA/014/3 z dnia 11.12.2012 r. | na podstawie testu Merck Nr 1.14752","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,010 – 0,500) mg/l N-NH4"},{"name":"Range","range":"(0,013 – 0,644) mg/l NH4 +"}],"search_en":"Water intended for human consumption Spectrophotometric method Range Range ON/IA/014/3 z dnia 11.12.2012 r. | na podstawie testu Merck Nr 1.14752","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,010 – 0,500) mg/l N-NH4"},{"name":"范围","range":"(0,013 – 0,644) mg/l NH4 +"}],"search_zh":"生活饮用水 分光光度法 范围 范围 ON/IA/014/3 z dnia 11.12.2012 r. | na podstawie testu Merck Nr 1.14752","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a7f0f3b1995264369d8e38d","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,010 – 0,120) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie manganu\nZakres (0,010 – 0,120) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 metoda A","norm_bases":["PN-ISO 8288:2002 metoda A"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie manganu\nZakres (0,010 – 0,120) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A Woda do spozycia przez ludzi Stezenie manganu\nZakres (0,010 – 0,120) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(0,010 – 0,120) mg/l"}],"search_en":"Water intended for human consumption Manganese concentration Flame atomic absorption spectrometry (FAAS) Range PN-ISO 8288:2002 metoda A","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water intended for human consumption","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 0,120) mg/l"}],"search_zh":"生活饮用水 锰浓度 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 8288:2002 metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"生活饮用水"},{"_id":"6a7f0f3b1995264369d8e38e","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a7f0f3b1995264369d8e38f","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Ścieki","methodology":"Temperatura ścieku / pobranej próbki ścieku","parameters":[{"name":"Zakres","range":"(0,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura ścieku / pobranej próbki ścieku\nZakres (0,0 – 50,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Temperatura ścieku / pobranej próbki ścieku\nZakres (0,0 – 50,0) °C PN-77/C-04584 Scieki Temperatura scieku / pobranej probki scieku\nZakres (0,0 – 50,0) °C PN-77/C-04584","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature of wastewater / of the collected wastewater sample","parameters_en":[{"name":"Range","range":"(0,0 – 50,0) °C"}],"search_en":"Wastewater Temperature of wastewater / of the collected wastewater sample Range PN-77/C-04584","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,0 – 50,0) °C"}],"search_zh":"污水 范围 PN-77/C-04584","test_object_zh":"污水"},{"_id":"6a7f0f3b1995264369d8e390","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT","parameters":[{"name":"Zakres","range":"(30 – 2000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (30 – 2000) mg/l O2\nMetoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (30 – 2000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006 Scieki Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (30 – 2000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand - COD","parameters_en":[{"name":"Range","range":"(30 – 2000) mg/l O2"}],"search_en":"Wastewater Chemical oxygen demand - COD Titrimetric method Range PN-ISO 6060:2006","technique_en":"Titrimetric method","test_object_en":"Wastewater","methodology_zh":"化学需氧量 ChZT（COD）","parameters_zh":[{"name":"范围","range":"(30 – 2000) mg/l O2"}],"search_zh":"污水 化学需氧量 ChZT（COD） 滴定法 范围 PN-ISO 6060:2006","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a7f0f3b1995264369d8e391","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,10 – 100) µg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,10 – 100) µg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN ISO 12846:2012 + Ap1:2016-07 pkt. 6","norm_bases":["PN-EN ISO 12846:2012 + Ap1:2016-07 pkt. 6"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie rtęci\nZakres (0,10 – 100) µg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012 + Ap1:2016-07 pkt. 6 Scieki Stezenie rteci\nZakres (0,10 – 100) µg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012 + Ap1:2016-07 pkt. 6","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,10 – 100) µg/l"}],"search_en":"Wastewater Mercury concentration Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN ISO 12846:2012 + Ap1:2016-07 pkt. 6","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"Wastewater","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 100) µg/l"}],"search_zh":"污水 汞浓度 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN ISO 12846:2012 + Ap1:2016-07 pkt. 6","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"污水"},{"_id":"6a7f0f3b1995264369d8e392","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Ścieki","methodology":"Indeks fenolowy","parameters":[{"name":"Zakres","range":"(0,002 – 2,50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Indeks fenolowy\nZakres (0,002 – 2,50) mg/l\nMetoda spektrofotometryczna","reference":"ON/IA/017/1 z dnia 09.10.2007 r. | na podstawie testu Merck Nr 1.00856","norm_bases":["ON/IA/017/1 z dnia 09.10.2007 r.","na podstawie testu Merck Nr 1.00856"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Indeks fenolowy\nZakres (0,002 – 2,50) mg/l\nMetoda spektrofotometryczna ON/IA/017/1 z dnia 09.10.2007 r. | na podstawie testu Merck Nr 1.00856 Scieki Indeks fenolowy\nZakres (0,002 – 2,50) mg/l\nMetoda spektrofotometryczna ON/IA/017/1 z dnia 09.10.2007 r. | na podstawie testu Merck Nr 1.00856","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol index","parameters_en":[{"name":"Range","range":"(0,002 – 2,50) mg/l"}],"search_en":"Wastewater Phenol index Spectrophotometric method Range ON/IA/017/1 z dnia 09.10.2007 r. | na podstawie testu Merck Nr 1.00856","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,002 – 2,50) mg/l"}],"search_zh":"污水 酚指数 分光光度法 范围 ON/IA/017/1 z dnia 09.10.2007 r. | na podstawie testu Merck Nr 1.00856","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"酚指数"},{"_id":"6a7f0f3b1995264369d8e393","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Ścieki oczyszczone","methodology":"Stężenie metali","parameters":[{"name":"ołów","range":"(0,100 – 1,00) mg/l"},{"name":"kadm","range":"(0,02 – 0,80) mg/l"},{"name":"miedź","range":"(0,05 – 1,00) mg/l"},{"name":"nikiel","range":"(0,100 – 1,00) mg/l"},{"name":"cynk","range":"(0,050 – 2,10) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie metali\nZakres:\nołów (0,100 – 1,00) mg/l\nkadm (0,02 – 0,80) mg/l\nmiedź (0,05 – 1,00) mg/l\nnikiel (0,100 – 1,00) mg/l\ncynk (0,050 – 2,10) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 metoda A","norm_bases":["PN-ISO 8288:2002 metoda A"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki oczyszczone Stężenie metali\nZakres:\nołów (0,100 – 1,00) mg/l\nkadm (0,02 – 0,80) mg/l\nmiedź (0,05 – 1,00) mg/l\nnikiel (0,100 – 1,00) mg/l\ncynk (0,050 – 2,10) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A Scieki oczyszczone Stezenie metali\nZakres:\nolow (0,100 – 1,00) mg/l\nkadm (0,02 – 0,80) mg/l\nmiedz (0,05 – 1,00) mg/l\nnikiel (0,100 – 1,00) mg/l\ncynk (0,050 – 2,10) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A","categories":["materials","water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations","parameters_en":[{"name":"lead","range":"(0,100 – 1,00) mg/l"},{"name":"cadmium","range":"(0,02 – 0,80) mg/l"},{"name":"copper","range":"(0,05 – 1,00) mg/l"},{"name":"nickel","range":"(0,100 – 1,00) mg/l"},{"name":"zinc","range":"(0,050 – 2,10) mg/l"}],"search_en":"Treated wastewater Metal concentrations Flame atomic absorption spectrometry (FAAS) lead cadmium copper nickel zinc PN-ISO 8288:2002 metoda A","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Treated wastewater","methodology_zh":"金属浓度","parameters_zh":[{"name":"铅","range":"(0,100 – 1,00) mg/l"},{"name":"镉","range":"(0,02 – 0,80) mg/l"},{"name":"铜","range":"(0,05 – 1,00) mg/l"},{"name":"镍","range":"(0,100 – 1,00) mg/l"},{"name":"锌","range":"(0,050 – 2,10) mg/l"}],"search_zh":"处理后废水 金属浓度 火焰原子吸收光谱法（FAAS） 铅 镉 铜 镍 锌 PN-ISO 8288:2002 metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"处理后废水"},{"_id":"6a7f0f3b1995264369d8e394","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,20 – 1 000) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,20 – 1 000) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Mętność\nZakres (0,20 – 1 000) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, woda do spozycia przez ludzi Metnosc\nZakres (0,20 – 1 000) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,20 – 1 000) NTU"}],"search_en":"Water, water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 – 1 000) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水"},{"_id":"6a7f0f3b1995264369d8e395","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie azotu azotynowego /azotynów","parameters":[{"name":"Zakres","range":"(0,003 – 0,152) mg/l N-NO2"},{"name":"Zakres","range":"(0,010 – 0,500) mg/l NO2-"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego /azotynów\nZakres:\nZakres (0,003 – 0,152) mg/l N-NO2\nZakres (0,010 – 0,500) mg/l NO2-\nMetoda spektrofotometryczna","reference":"ON/IA/013/1 z dnia 05.10.2007 r. | na podstawie testu Merck Nr 1.14776","norm_bases":["ON/IA/013/1 z dnia 05.10.2007 r.","na podstawie testu Merck Nr 1.14776"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotu azotynowego /azotynów\nZakres:\nZakres (0,003 – 0,152) mg/l N-NO2\nZakres (0,010 – 0,500) mg/l NO2-\nMetoda spektrofotometryczna ON/IA/013/1 z dnia 05.10.2007 r. | na podstawie testu Merck Nr 1.14776 Woda, woda do spozycia przez ludzi Stezenie azotu azotynowego /azotynow\nZakres:\nZakres (0,003 – 0,152) mg/l N-NO2\nZakres (0,010 – 0,500) mg/l NO2-\nMetoda spektrofotometryczna ON/IA/013/1 z dnia 05.10.2007 r. | na podstawie testu Merck Nr 1.14776","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,003 – 0,152) mg/l N-NO2"},{"name":"Range","range":"(0,010 – 0,500) mg/l NO2-"}],"search_en":"Water, water intended for human consumption Spectrophotometric method Range Range ON/IA/013/1 z dnia 05.10.2007 r. | na podstawie testu Merck Nr 1.14776","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,003 – 0,152) mg/l N-NO2"},{"name":"范围","range":"(0,010 – 0,500) mg/l NO2-"}],"search_zh":"水、生活饮用水 分光光度法 范围 范围 ON/IA/013/1 z dnia 05.10.2007 r. | na podstawie testu Merck Nr 1.14776","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f0f3b1995264369d8e396","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie glinu","parameters":[{"name":"Zakres","range":"(0,020 – 0,200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie glinu\nZakres (0,020 – 0,200) mg/l\nMetoda spektrofotometryczna","reference":"ON/IA/015/2 z dnia 14.12.2009 r. | na podstawie testu Merck Nr 1.00594","norm_bases":["ON/IA/015/2 z dnia 14.12.2009 r.","na podstawie testu Merck Nr 1.00594"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie glinu\nZakres (0,020 – 0,200) mg/l\nMetoda spektrofotometryczna ON/IA/015/2 z dnia 14.12.2009 r. | na podstawie testu Merck Nr 1.00594 Woda, woda do spozycia przez ludzi Stezenie glinu\nZakres (0,020 – 0,200) mg/l\nMetoda spektrofotometryczna ON/IA/015/2 z dnia 14.12.2009 r. | na podstawie testu Merck Nr 1.00594","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Aluminium concentration","parameters_en":[{"name":"Range","range":"(0,020 – 0,200) mg/l"}],"search_en":"Water, water intended for human consumption Aluminium concentration Spectrophotometric method Range ON/IA/015/2 z dnia 14.12.2009 r. | na podstawie testu Merck Nr 1.00594","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,020 – 0,200) mg/l"}],"search_zh":"水、生活饮用水 铝浓度 分光光度法 范围 ON/IA/015/2 z dnia 14.12.2009 r. | na podstawie testu Merck Nr 1.00594","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","methodology_zh":"铝浓度"},{"_id":"6a7f0f3b1995264369d8e397","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,010 – 0,800) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (0,010 – 0,800) mg/l\nMetoda spektrofotometryczna","reference":"ON/IA/016/1 z dnia 09.10.2007 r. | na podstawie testu Merck Nr 1.14770","norm_bases":["ON/IA/016/1 z dnia 09.10.2007 r.","na podstawie testu Merck Nr 1.14770"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie manganu\nZakres (0,010 – 0,800) mg/l\nMetoda spektrofotometryczna ON/IA/016/1 z dnia 09.10.2007 r. | na podstawie testu Merck Nr 1.14770 Woda, woda do spozycia przez ludzi Stezenie manganu\nZakres (0,010 – 0,800) mg/l\nMetoda spektrofotometryczna ON/IA/016/1 z dnia 09.10.2007 r. | na podstawie testu Merck Nr 1.14770","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(0,010 – 0,800) mg/l"}],"search_en":"Water, water intended for human consumption Manganese concentration Spectrophotometric method Range ON/IA/016/1 z dnia 09.10.2007 r. | na podstawie testu Merck Nr 1.14770","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 0,800) mg/l"}],"search_zh":"水、生活饮用水 锰浓度 分光光度法 范围 ON/IA/016/1 z dnia 09.10.2007 r. | na podstawie testu Merck Nr 1.14770","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f0f3b1995264369d8e398","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(2 – 100) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (2 – 100) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 Metoda C","norm_bases":["PN-EN ISO 7887:2012 Metoda C"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Barwa\nZakres (2 – 100) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C Woda, woda do spozycia przez ludzi Barwa\nZakres (2 – 100) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(2 – 100) mg/l Pt"}],"search_en":"Water, water intended for human consumption Colour Spectrophotometric method Range PN-EN ISO 7887:2012 Metoda C","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(2 – 100) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 分光光度法 范围 PN-EN ISO 7887:2012 Metoda C","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f0f3b1995264369d8e399","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, woda do spozycia przez ludzi, scieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Water, water intended for human consumption, wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"水、生活饮用水、污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a7f0f3b1995264369d8e39a","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(5,0 – 4 000) µS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (5,0 – 4 000) µS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Przewodność elektryczna właściwa\nZakres (5,0 – 4 000) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, woda do spozycia przez ludzi, scieki Przewodnosc elektryczna wlasciwa\nZakres (5,0 – 4 000) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(5,0 – 4 000) µS/cm"}],"search_en":"Water, water intended for human consumption, wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(5,0 – 4 000) µS/cm"}],"search_zh":"水、生活饮用水、污水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a7f0f3b1995264369d8e39b","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie azotu azotanowego /azotanów","parameters":[{"name":"Zakres","range":"(0,10 – 18,0) mg/l N-NO3"},{"name":"Zakres","range":"(0,5 – 79,9) mg/l NO3-"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego /azotanów\nZakres:\nZakres (0,10 – 18,0) mg/l N-NO3\nZakres (0,5 – 79,9) mg/l NO3-\nMetoda spektrofotometryczna","reference":"ON/IA/012/2 z dnia 07.12.2011 r. | na podstawie testu Merck Nr 1.14556, Nr 1.14542","norm_bases":["ON/IA/012/2 z dnia 07.12.2011 r.","na podstawie testu Merck Nr 1.14556, Nr 1.14542"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie azotu azotanowego /azotanów\nZakres:\nZakres (0,10 – 18,0) mg/l N-NO3\nZakres (0,5 – 79,9) mg/l NO3-\nMetoda spektrofotometryczna ON/IA/012/2 z dnia 07.12.2011 r. | na podstawie testu Merck Nr 1.14556, Nr 1.14542 Woda, woda do spozycia przez ludzi, scieki Stezenie azotu azotanowego /azotanow\nZakres:\nZakres (0,10 – 18,0) mg/l N-NO3\nZakres (0,5 – 79,9) mg/l NO3-\nMetoda spektrofotometryczna ON/IA/012/2 z dnia 07.12.2011 r. | na podstawie testu Merck Nr 1.14556, Nr 1.14542","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,10 – 18,0) mg/l N-NO3"},{"name":"Range","range":"(0,5 – 79,9) mg/l NO3-"}],"search_en":"Water, water intended for human consumption, wastewater Spectrophotometric method Range Range ON/IA/012/2 z dnia 07.12.2011 r. | na podstawie testu Merck Nr 1.14556, Nr 1.14542","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,10 – 18,0) mg/l N-NO3"},{"name":"范围","range":"(0,5 – 79,9) mg/l NO3-"}],"search_zh":"水、生活饮用水、污水 分光光度法 范围 范围 ON/IA/012/2 z dnia 07.12.2011 r. | na podstawie testu Merck Nr 1.14556, Nr 1.14542","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a7f0f3b1995264369d8e39c","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,05 – 5,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,05 – 5,00) mg/l\nMetoda spektrofotometryczna","reference":"ON/IA/010/2 z dnia 22.11.2011 r. | na podstawie testu Merck Nr 1.14543","norm_bases":["ON/IA/010/2 z dnia 22.11.2011 r.","na podstawie testu Merck Nr 1.14543"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,05 – 5,00) mg/l\nMetoda spektrofotometryczna ON/IA/010/2 z dnia 22.11.2011 r. | na podstawie testu Merck Nr 1.14543 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,05 – 5,00) mg/l\nMetoda spektrofotometryczna ON/IA/010/2 z dnia 22.11.2011 r. | na podstawie testu Merck Nr 1.14543","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,05 – 5,00) mg/l"}],"search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Range ON/IA/010/2 z dnia 22.11.2011 r. | na podstawie testu Merck Nr 1.14543","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 5,00) mg/l"}],"search_zh":"水、废水 总磷浓度 分光光度法 范围 ON/IA/010/2 z dnia 22.11.2011 r. | na podstawie testu Merck Nr 1.14543","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a7f0f3b1995264369d8e39d","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie węglowodorów aromatycznych (BTEX):","parameters":[{"name":"benzen"},{"name":"toluen"},{"name":"etylobenzen"},{"name":"Zakres","range":"(0,005 – 2,0) mg/l"},{"name":"suma ksylenów"},{"name":"Zakres","range":"(0,015 – 6,0) mg/l"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)"],"computed":[],"activity":"Stężenie węglowodorów aromatycznych (BTEX):\nZakres:\nbenzen\ntoluen\netylobenzen\nZakres (0,005 – 2,0) mg/l\nsuma ksylenów\nZakres (0,015 – 6,0) mg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","reference":"PN-ISO 11423-1:2002","norm_bases":["PN-ISO 11423-1:2002"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie węglowodorów aromatycznych (BTEX):\nZakres:\nbenzen\ntoluen\netylobenzen\nZakres (0,005 – 2,0) mg/l\nsuma ksylenów\nZakres (0,015 – 6,0) mg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID) PN-ISO 11423-1:2002 Woda, scieki Stezenie weglowodorow aromatycznych (BTEX):\nZakres:\nbenzen\ntoluen\netylobenzen\nZakres (0,005 – 2,0) mg/l\nsuma ksylenow\nZakres (0,015 – 6,0) mg/l\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja plomieniowo-jonizacyjna (HS-GC-FID) PN-ISO 11423-1:2002","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"benzene"},{"name":"toluene"},{"name":"ethylbenzene"},{"name":"Range","range":"(0,005 – 2,0) mg/l"},{"name":"sum of xylenes"},{"name":"Range","range":"(0,015 – 6,0) mg/l"}],"search_en":"Water, wastewater Headspace gas chromatography with flame ionization detection (HS-GC-FID) benzene toluene ethylbenzene Range sum of xylenes Range PN-ISO 11423-1:2002","technique_en":"Headspace gas chromatography with flame ionization detection (HS-GC-FID)","test_object_en":"Water, wastewater","parameters_zh":[{"name":"苯"},{"name":"甲苯"},{"name":"乙苯"},{"name":"范围","range":"(0,005 – 2,0) mg/l"},{"name":"二甲苯总量"},{"name":"范围","range":"(0,015 – 6,0) mg/l"}],"search_zh":"水、废水 顶空气相色谱-火焰离子化检测法（HS-GC-FID） 苯 甲苯 乙苯 范围 二甲苯总量 范围 PN-ISO 11423-1:2002","test_object_zh":"水、废水","technique_zh":"顶空气相色谱-火焰离子化检测法（HS-GC-FID）"},{"_id":"6a7f0f3b1995264369d8e39e","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT","parameters":[{"name":"Zakres","range":"(4,0 – 40,0) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (4,0 – 40,0) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (4,0 – 40,0) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (4,0 – 40,0) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand - COD","parameters_en":[{"name":"Range","range":"(4,0 – 40,0) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand - COD Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"化学需氧量 ChZT（COD）","parameters_zh":[{"name":"范围","range":"(4,0 – 40,0) mg/l O2"}],"search_zh":"水、废水 化学需氧量 ChZT（COD） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a7f0f3b1995264369d8e39f","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 500) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007 + Ap1:2007","norm_bases":["PN-EN 872:2007 + Ap1:2007"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (2,0 – 500) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (2,0 – 500) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap1:2007","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 500) mg/l"}],"search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007 + Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 500) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 范围 PN-EN 872:2007 + Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a7f0f3b1995264369d8e3a0","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Indeks oleju mineralnego (stężenie węglowodorów C10-C40)","parameters":[{"name":"Zakres","range":"(0,12 – 18) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Indeks oleju mineralnego (stężenie węglowodorów C10-C40)\nZakres (0,12 – 18) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Indeks oleju mineralnego (stężenie węglowodorów C10-C40)\nZakres (0,12 – 18) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda, scieki Indeks oleju mineralnego (stezenie weglowodorow C10-C40)\nZakres (0,12 – 18) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,12 – 18) mg/l"}],"search_en":"Water, wastewater Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,12 – 18) mg/l"}],"search_zh":"水、废水 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"水、废水"},{"_id":"6a7f0f3b1995264369d8e3a1","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(5 – 500) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczanów\nZakres (5 – 500) mg/l\nMetoda spektrofotometryczna","reference":"ON/IA/019/2 z dnia 07.04.2021 r. | na podstawie testu Merck Nr 1.14548; 1.00617","norm_bases":["ON/IA/019/2 z dnia 07.04.2021 r.","na podstawie testu Merck Nr 1.14548; 1.00617"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie siarczanów\nZakres (5 – 500) mg/l\nMetoda spektrofotometryczna ON/IA/019/2 z dnia 07.04.2021 r. | na podstawie testu Merck Nr 1.14548; 1.00617 Woda, scieki Stezenie siarczanow\nZakres (5 – 500) mg/l\nMetoda spektrofotometryczna ON/IA/019/2 z dnia 07.04.2021 r. | na podstawie testu Merck Nr 1.14548; 1.00617","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(5 – 500) mg/l"}],"search_en":"Water, wastewater Sulfate concentration Spectrophotometric method Range ON/IA/019/2 z dnia 07.04.2021 r. | na podstawie testu Merck Nr 1.14548; 1.00617","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(5 – 500) mg/l"}],"search_zh":"水、废水 硫酸盐浓度 分光光度法 范围 ON/IA/019/2 z dnia 07.04.2021 r. | na podstawie testu Merck Nr 1.14548; 1.00617","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a7f0f3b1995264369d8e3a2","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego / jonu amonowego","parameters":[{"name":"Zakres","range":"(0,010 – 1,500) mg/l N-NH4"},{"name":"Zakres","range":"(0,013 – 1,93) mg/l NH4 +"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego / jonu amonowego\nZakres:\nZakres (0,010 – 1,500) mg/l N-NH4\nZakres (0,013 – 1,93) mg/l NH4 +\nMetoda spektrofotometryczna","reference":"ON/IA/014/3 z dnia 11.12.2012 r. | na podstawie testu Merck Nr 1.14752","norm_bases":["ON/IA/014/3 z dnia 11.12.2012 r.","na podstawie testu Merck Nr 1.14752"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego / jonu amonowego\nZakres:\nZakres (0,010 – 1,500) mg/l N-NH4\nZakres (0,013 – 1,93) mg/l NH4 +\nMetoda spektrofotometryczna ON/IA/014/3 z dnia 11.12.2012 r. | na podstawie testu Merck Nr 1.14752 Woda, scieki Stezenie azotu amonowego / jonu amonowego\nZakres:\nZakres (0,010 – 1,500) mg/l N-NH4\nZakres (0,013 – 1,93) mg/l NH4 +\nMetoda spektrofotometryczna ON/IA/014/3 z dnia 11.12.2012 r. | na podstawie testu Merck Nr 1.14752","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,010 – 1,500) mg/l N-NH4"},{"name":"Range","range":"(0,013 – 1,93) mg/l NH4 +"}],"search_en":"Water, wastewater Spectrophotometric method Range Range ON/IA/014/3 z dnia 11.12.2012 r. | na podstawie testu Merck Nr 1.14752","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,010 – 1,500) mg/l N-NH4"},{"name":"范围","range":"(0,013 – 1,93) mg/l NH4 +"}],"search_zh":"水、废水 分光光度法 范围 范围 ON/IA/014/3 z dnia 11.12.2012 r. | na podstawie testu Merck Nr 1.14752","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a7f0f3b1995264369d8e3a3","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chlorków\nZakres (5,0 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, scieki Stezenie chlorkow\nZakres (5,0 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 400) mg/l"}],"search_en":"Water, wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 400) mg/l"}],"search_zh":"水、废水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a7f0f3b1995264369d8e3a4","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(0,5 – 75,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (0,5 – 75,0) mg/l\nMetoda spektrofotometryczna","reference":"ON/IA/011/2 z dnia 22.11.2011 r. | na podstawie testu Merck Nr 1.14537","norm_bases":["ON/IA/011/2 z dnia 22.11.2011 r.","na podstawie testu Merck Nr 1.14537"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu ogólnego\nZakres (0,5 – 75,0) mg/l\nMetoda spektrofotometryczna ON/IA/011/2 z dnia 22.11.2011 r. | na podstawie testu Merck Nr 1.14537 Woda, scieki Stezenie azotu ogolnego\nZakres (0,5 – 75,0) mg/l\nMetoda spektrofotometryczna ON/IA/011/2 z dnia 22.11.2011 r. | na podstawie testu Merck Nr 1.14537","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,5 – 75,0) mg/l"}],"search_en":"Water, wastewater Total nitrogen concentration Spectrophotometric method Range ON/IA/011/2 z dnia 22.11.2011 r. | na podstawie testu Merck Nr 1.14537","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(0,5 – 75,0) mg/l"}],"search_zh":"水、废水 总氮浓度 分光光度法 范围 ON/IA/011/2 z dnia 22.11.2011 r. | na podstawie testu Merck Nr 1.14537","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a7f0f3b1995264369d8e3a5","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Środowisko pracy − hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(35 − 119) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres (35 − 119) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 - punkt 10 i strategię 3 - punkt 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 - punkt 10 i strategię 3 - punkt 11"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres (35 − 119) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 - punkt 10 i strategię 3 - punkt 11 Srodowisko pracy − halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres (35 − 119) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wylaczeniem metod obejmujacych strategie 2 - punkt 10 i strategie 3 - punkt 11","categories":["environment"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(35 − 119) dB"}],"search_en":"Workplace environment − noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 - punkt 10 i strategię 3 - punkt 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment − noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(35 − 119) dB"}],"search_zh":"工作环境 − 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 - punkt 10 i strategię 3 - punkt 11","technique_zh":"直接测量法","test_object_zh":"工作环境 − 噪声"},{"_id":"6a7f0f3b1995264369d8e3a6","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Środowisko pracy − hałas","methodology":"Szczytowy poziom dźwięku C","parameters":[{"name":"Zakres","range":"(35 − 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Szczytowy poziom dźwięku C\nZakres (35 − 135) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 - punkt 10 i strategię 3 - punkt 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 - punkt 10 i strategię 3 - punkt 11"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − hałas Szczytowy poziom dźwięku C\nZakres (35 − 135) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 - punkt 10 i strategię 3 - punkt 11 Srodowisko pracy − halas Szczytowy poziom dzwieku C\nZakres (35 − 135) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wylaczeniem metod obejmujacych strategie 2 - punkt 10 i strategie 3 - punkt 11","categories":["environment"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"C-weighted peak sound pressure level","parameters_en":[{"name":"Range","range":"(35 − 135) dB"}],"search_en":"Workplace environment − noise C-weighted peak sound pressure level Direct measurement method Range PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 - punkt 10 i strategię 3 - punkt 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment − noise","methodology_zh":"C 计权峰值声级","parameters_zh":[{"name":"范围","range":"(35 − 135) dB"}],"search_zh":"工作环境 − 噪声 C 计权峰值声级 直接测量法 范围 PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 - punkt 10 i strategię 3 - punkt 11","technique_zh":"直接测量法","test_object_zh":"工作环境 − 噪声"},{"_id":"6a7f0f3b1995264369d8e3a7","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Środowisko pracy − hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godzinnego dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 - punkt 10 i strategię 3 - punkt 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 - punkt 10 i strategię 3 - punkt 11"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 - punkt 10 i strategię 3 - punkt 11 Srodowisko pracy − halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wylaczeniem metod obejmujacych strategie 2 - punkt 10 i strategie 3 - punkt 11","categories":["environment"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment − noise Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 - punkt 10 i strategię 3 - punkt 11","test_object_en":"Workplace environment − noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作环境 − 噪声 噪声暴露级，参照： 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 - punkt 10 i strategię 3 - punkt 11","test_object_zh":"工作环境 − 噪声"},{"_id":"6a7f0f3b1995264369d8e3a8","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe – frakcja wdychalna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nczynniki pyłowe – frakcja wdychalna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 + Az1:2004","norm_bases":["PN-Z-04008-7:2002 + Az1:2004"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nczynniki pyłowe – frakcja wdychalna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 + Az1:2004 Srodowisko pracy − powietrze Pobieranie probek do oceny narazenia zawodowego na:\nczynniki pylowe – frakcja wdychalna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 + Az1:2004","categories":["environment"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","search_en":"Workplace environment − air Sampling for the assessment of occupational exposure to: Personal dosimetry method PN-Z-04008-7:2002 + Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment − air","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作环境 − 空气 职业接触评估采样，针对： 个体剂量测定法 PN-Z-04008-7:2002 + Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作环境 − 空气"},{"_id":"6a7f0f3b1995264369d8e3a9","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"substancje organiczne, w tym – frakcja wdychalna"},{"name":"substancje nieorganiczne"}],"technique":"Metoda stacjonarna; Metoda dozymetrii indywidualnej","techniques":["Metoda stacjonarna","Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne\nMetoda stacjonarna; Metoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 + Az1:2004","norm_bases":["PN-Z-04008-7:2002 + Az1:2004"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne\nMetoda stacjonarna; Metoda dozymetrii indywidualnej PN-Z-04008-7:2002 + Az1:2004 Srodowisko pracy − powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne\nMetoda stacjonarna; Metoda dozymetrii indywidualnej PN-Z-04008-7:2002 + Az1:2004","categories":["environment"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"organic substances, including – inhalable fraction"},{"name":"inorganic substances"}],"search_en":"Workplace environment − air Sampling for the assessment of occupational exposure to: Stationary method; Personal dosimetry method organic substances, including – inhalable fraction inorganic substances PN-Z-04008-7:2002 + Az1:2004","technique_en":"Stationary method; Personal dosimetry method","test_object_en":"Workplace environment − air","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作环境 − 空气 职业接触评估采样，针对： 定点法；个体剂量测定法 有机物质，包括 — 可吸入组分 无机物质 PN-Z-04008-7:2002 + Az1:2004","test_object_zh":"工作环境 − 空气","parameters_zh":[{"name":"有机物质，包括 — 可吸入组分"},{"name":"无机物质"}],"technique_zh":"定点法；个体剂量测定法"},{"_id":"6a7f0f3b1995264369d8e3aa","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002 + Az1:2004","norm_bases":["PN-Z-04008-7:2002 + Az1:2004"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002 + Az1:2004 Srodowisko pracy − powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002 + Az1:2004","categories":["environment"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment − air Exposure index (calculated) PN-Z-04008-7:2002 + Az1:2004","test_object_en":"Workplace environment − air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作环境 − 空气 暴露指数（计算得出） PN-Z-04008-7:2002 + Az1:2004","test_object_zh":"工作环境 − 空气"},{"_id":"6a7f0f3b1995264369d8e3ab","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia − frakcja wdychalna","parameters":[{"name":"pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Zakres","range":"(0,58 – 17,4) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia − frakcja wdychalna\nZakres:\npyły niesklasyfikowane ze względu na toksyczność\nZakres (0,58 – 17,4) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia − frakcja wdychalna\nZakres:\npyły niesklasyfikowane ze względu na toksyczność\nZakres (0,58 – 17,4) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy − powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia − frakcja wdychalna\nZakres:\npyly niesklasyfikowane ze wzgledu na toksycznosc\nZakres (0,58 – 17,4) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents − inhalable fraction","parameters_en":[{"name":"dusts not classified according to toxicity"},{"name":"Range","range":"(0,58 – 17,4) mg/m3"}],"search_en":"Workplace environment − air Concentration of harmful dust agents − inhalable fraction Gravimetric method dusts not classified according to toxicity Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"未按毒性分类的粉尘"},{"name":"范围","range":"(0,58 – 17,4) mg/m3"}],"search_zh":"工作环境 − 空气 重量法 未按毒性分类的粉尘 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作环境 − 空气"},{"_id":"6a7f0f3b1995264369d8e3ac","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie amoniaku","parameters":[{"name":"Zakres","range":"(1,25 – 58,4) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie amoniaku\nZakres (1,25 – 58,4) mg/m3\nMetoda spektrofotometryczna","reference":"PN-71/Z-04041","norm_bases":["PN-71/Z-04041"],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie amoniaku\nZakres (1,25 – 58,4) mg/m3\nMetoda spektrofotometryczna PN-71/Z-04041 Srodowisko pracy − powietrze Stezenie amoniaku\nZakres (1,25 – 58,4) mg/m3\nMetoda spektrofotometryczna PN-71/Z-04041","categories":["environment"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonia concentration","parameters_en":[{"name":"Range","range":"(1,25 – 58,4) mg/m3"}],"search_en":"Workplace environment − air Ammonia concentration Spectrophotometric method Range PN-71/Z-04041","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(1,25 – 58,4) mg/m3"}],"search_zh":"工作环境 − 空气 氨浓度 分光光度法 范围 PN-71/Z-04041","technique_zh":"分光光度法","test_object_zh":"工作环境 − 空气","methodology_zh":"氨浓度"},{"_id":"6a7f0f3b1995264369d8e3ad","lab_id":"69ad52a3de79e566650fb574","country":"PL","accr_number":"AB 1072","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie substancji organicznych","parameters":[{"name":"aceton","range":"(22 – 3600) mg/m3"},{"name":"aceton","range":"(40 – 1350) µg w próbce"},{"name":"metanol","range":"(2,8 – 600) mg/m3"},{"name":"metanol","range":"(5,0 – 250) µg w próbce"},{"name":"chlorobenzen","range":"(0,9 – 140) mg/m3"},{"name":"chlorobenzen","range":"(1,7 – 75,0) µg w próbce"},{"name":"toluen","range":"(2,8 – 400) mg/m3"},{"name":"toluen","range":"(5,0 – 200) µg w próbce"},{"name":"etanol","range":"(66,7 – 3825) mg/m3"},{"name":"etanol","range":"(120 – 2800) µg w próbce"},{"name":"1-chloro-2,3-epoksypropan","range":"(0,111 – 2,837) mg/m3"},{"name":"1-chloro-2,3-epoksypropan","range":"(0,104 – 2,128) µg w próbce"},{"name":"octan etylu","range":"(2,8 – 2936) mg/m3"},{"name":"octan etylu","range":"(30,0 – 1200) µg w próbce"},{"name":"octan etylu","range":"(0,77 – 804) ppm"},{"name":"4-metylopentan-2-on","range":"(2,8 – 400) mg/m3"},{"name":"4-metylopentan-2-on","range":"(5,0 – 200) µg w próbce"},{"name":"benzen","range":"(0,060 – 3,473) mg/m3"},{"name":"benzen","range":"(0,108 – 2,584) µg w próbce"},{"name":"benzen","range":"(0,02 – 1,1) ppm"},{"name":"propan-2-ol","range":"(36 – 2400) mg/m3"},{"name":"propan-2-ol","range":"(65 – 1355) µg w próbce"},{"name":"chloro(fenylo)metan","range":"(0,27–18) mg/m3"},{"name":"chloro(fenylo)metan","range":"(0,20 ÷ 9,0) µg w próbce"},{"name":"dichlorometan","range":"(2,8 – 707) mg/m3"},{"name":"dichlorometan","range":"(5,0 – 270) µg w próbce"},{"name":"dichlorometan","range":"(0,79 – 200) ppm"},{"name":"chloroform","range":"(0,78 – 40,0) mg/m3"},{"name":"chloroform","range":"(0,60 – 30,0) µg w próbce"},{"name":"fenol","range":"(0,78 – 40,0) mg/m3"},{"name":"fenol","range":"(0,50 – 30,0) µg"},{"name":"kwas octowy","range":"(2,5 – 100) mg/m3"},{"name":"kwas octowy","range":"(2,30 – 59,1) µg w próbce"},{"name":"kwas octowy","range":"(1,0 – 40) ppm"},{"name":"pirydyna","range":"(0,50 – 25,2) mg/m3"},{"name":"pirydyna","range":"(0,75 – 19,1) µg w próbce"},{"name":"tetrahydrofuran","range":"(2,8 – 600) mg/m3"},{"name":"tetrahydrofuran","range":"(5,0 ÷ 225) µg"},{"name":"N,N-dimetyloformamid","range":"(0,60 – 600) mg/m3"},{"name":"N,N-dimetyloformamid","range":"(1,01 – 24,0) µg w próbce"},{"name":"N,N-dimetyloformamid","range":"(0,20 – 20) ppm"}],"technique":"Metoda chromatografii gazowej z termodesorpcją i detekcją płomieniowo-jonizacyjną (TD-GC-FID)","techniques":["Metoda chromatografii gazowej z termodesorpcją i detekcją płomieniowo-jonizacyjną (TD-GC-FID)"],"computed":[],"activity":"Stężenie substancji organicznych\nZakres:\naceton (22 – 3600) mg/m3\naceton (40 – 1350) µg w próbce\nmetanol (2,8 – 600) mg/m3\nmetanol (5,0 – 250) µg w próbce\nchlorobenzen (0,9 – 140) mg/m3\nchlorobenzen (1,7 – 75,0) µg w próbce\ntoluen (2,8 – 400) mg/m3\ntoluen (5,0 – 200) µg w próbce\netanol (66,7 – 3825) mg/m3\netanol (120 – 2800) µg w próbce\n1-chloro-2,3-epoksypropan (0,111 – 2,837) mg/m3\n1-chloro-2,3-epoksypropan (0,104 – 2,128) µg w próbce\noctan etylu (2,8 – 2936) mg/m3\noctan etylu (30,0 – 1200) µg w próbce\noctan etylu (0,77 – 804) ppm\n4-metylopentan-2-on (2,8 – 400) mg/m3\n4-metylopentan-2-on (5,0 – 200) µg w próbce\nbenzen (0,060 – 3,473) mg/m3\nbenzen (0,108 – 2,584) µg w próbce\nbenzen (0,02 – 1,1) ppm\npropan-2-ol (36 – 2400) mg/m3\npropan-2-ol (65 – 1355) µg w próbce\nchloro(fenylo)metan (0,27–18) mg/m3\nchloro(fenylo)metan (0,20 ÷ 9,0) µg w próbce\ndichlorometan (2,8 – 707) mg/m3\ndichlorometan (5,0 – 270) µg w próbce\ndichlorometan (0,79 – 200) ppm\nchloroform (0,78 – 40,0) mg/m3\nchloroform (0,60 – 30,0) µg w próbce\nfenol (0,78 – 40,0) mg/m3\nfenol (0,50 – 30,0) µg\nkwas octowy (2,5 – 100) mg/m3\nkwas octowy (2,30 – 59,1) µg w próbce\nkwas octowy (1,0 – 40) ppm\npirydyna (0,50 – 25,2) mg/m3\npirydyna (0,75 – 19,1) µg w próbce\ntetrahydrofuran (2,8 – 600) mg/m3\ntetrahydrofuran (5,0 ÷ 225) µg\nN,N-dimetyloformamid (0,60 – 600) mg/m3\nN,N-dimetyloformamid (1,01 – 24,0) µg w próbce\nN,N-dimetyloformamid (0,20 – 20) ppm\nMetoda chromatografii gazowej z termodesorpcją i detekcją płomieniowo-jonizacyjną (TD-GC-FID)","reference":"M/24/6/2025 wydanie 6 z dnia 04.06.2025 r.","norm_bases":["M/24/6/2025 wydanie 6 z dnia 04.06.2025 r."],"lab_section":"Zespół Monitoringu Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie substancji organicznych\nZakres:\naceton (22 – 3600) mg/m3\naceton (40 – 1350) µg w próbce\nmetanol (2,8 – 600) mg/m3\nmetanol (5,0 – 250) µg w próbce\nchlorobenzen (0,9 – 140) mg/m3\nchlorobenzen (1,7 – 75,0) µg w próbce\ntoluen (2,8 – 400) mg/m3\ntoluen (5,0 – 200) µg w próbce\netanol (66,7 – 3825) mg/m3\netanol (120 – 2800) µg w próbce\n1-chloro-2,3-epoksypropan (0,111 – 2,837) mg/m3\n1-chloro-2,3-epoksypropan (0,104 – 2,128) µg w próbce\noctan etylu (2,8 – 2936) mg/m3\noctan etylu (30,0 – 1200) µg w próbce\noctan etylu (0,77 – 804) ppm\n4-metylopentan-2-on (2,8 – 400) mg/m3\n4-metylopentan-2-on (5,0 – 200) µg w próbce\nbenzen (0,060 – 3,473) mg/m3\nbenzen (0,108 – 2,584) µg w próbce\nbenzen (0,02 – 1,1) ppm\npropan-2-ol (36 – 2400) mg/m3\npropan-2-ol (65 – 1355) µg w próbce\nchloro(fenylo)metan (0,27–18) mg/m3\nchloro(fenylo)metan (0,20 ÷ 9,0) µg w próbce\ndichlorometan (2,8 – 707) mg/m3\ndichlorometan (5,0 – 270) µg w próbce\ndichlorometan (0,79 – 200) ppm\nchloroform (0,78 – 40,0) mg/m3\nchloroform (0,60 – 30,0) µg w próbce\nfenol (0,78 – 40,0) mg/m3\nfenol (0,50 – 30,0) µg\nkwas octowy (2,5 – 100) mg/m3\nkwas octowy (2,30 – 59,1) µg w próbce\nkwas octowy (1,0 – 40) ppm\npirydyna (0,50 – 25,2) mg/m3\npirydyna (0,75 – 19,1) µg w próbce\ntetrahydrofuran (2,8 – 600) mg/m3\ntetrahydrofuran (5,0 ÷ 225) µg\nN,N-dimetyloformamid (0,60 – 600) mg/m3\nN,N-dimetyloformamid (1,01 – 24,0) µg w próbce\nN,N-dimetyloformamid (0,20 – 20) ppm\nMetoda chromatografii gazowej z termodesorpcją i detekcją płomieniowo-jonizacyjną (TD-GC-FID) M/24/6/2025 wydanie 6 z dnia 04.06.2025 r. Srodowisko pracy − powietrze Stezenie substancji organicznych\nZakres:\naceton (22 – 3600) mg/m3\naceton (40 – 1350) µg w probce\nmetanol (2,8 – 600) mg/m3\nmetanol (5,0 – 250) µg w probce\nchlorobenzen (0,9 – 140) mg/m3\nchlorobenzen (1,7 – 75,0) µg w probce\ntoluen (2,8 – 400) mg/m3\ntoluen (5,0 – 200) µg w probce\netanol (66,7 – 3825) mg/m3\netanol (120 – 2800) µg w probce\n1-chloro-2,3-epoksypropan (0,111 – 2,837) mg/m3\n1-chloro-2,3-epoksypropan (0,104 – 2,128) µg w probce\noctan etylu (2,8 – 2936) mg/m3\noctan etylu (30,0 – 1200) µg w probce\noctan etylu (0,77 – 804) ppm\n4-metylopentan-2-on (2,8 – 400) mg/m3\n4-metylopentan-2-on (5,0 – 200) µg w probce\nbenzen (0,060 – 3,473) mg/m3\nbenzen (0,108 – 2,584) µg w probce\nbenzen (0,02 – 1,1) ppm\npropan-2-ol (36 – 2400) mg/m3\npropan-2-ol (65 – 1355) µg w probce\nchloro(fenylo)metan (0,27–18) mg/m3\nchloro(fenylo)metan (0,20 ÷ 9,0) µg w probce\ndichlorometan (2,8 – 707) mg/m3\ndichlorometan (5,0 – 270) µg w probce\ndichlorometan (0,79 – 200) ppm\nchloroform (0,78 – 40,0) mg/m3\nchloroform (0,60 – 30,0) µg w probce\nfenol (0,78 – 40,0) mg/m3\nfenol (0,50 – 30,0) µg\nkwas octowy (2,5 – 100) mg/m3\nkwas octowy (2,30 – 59,1) µg w probce\nkwas octowy (1,0 – 40) ppm\npirydyna (0,50 – 25,2) mg/m3\npirydyna (0,75 – 19,1) µg w probce\ntetrahydrofuran (2,8 – 600) mg/m3\ntetrahydrofuran (5,0 ÷ 225) µg\nN,N-dimetyloformamid (0,60 – 600) mg/m3\nN,N-dimetyloformamid (1,01 – 24,0) µg w probce\nN,N-dimetyloformamid (0,20 – 20) ppm\nMetoda chromatografii gazowej z termodesorpcja i detekcja plomieniowo-jonizacyjna (TD-GC-FID) M/24/6/2025 wydanie 6 z dnia 04.06.2025 r.","categories":["environment"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of organic substances","parameters_en":[{"name":"acetone","range":"(22 – 3600) mg/m3"},{"name":"acetone","range":"(40 – 1350) µg w próbce"},{"name":"methanol","range":"(2,8 – 600) mg/m3"},{"name":"methanol","range":"(5,0 – 250) µg w próbce"},{"name":"chlorobenzene","range":"(0,9 – 140) mg/m3"},{"name":"chlorobenzene","range":"(1,7 – 75,0) µg w próbce"},{"name":"toluene","range":"(2,8 – 400) mg/m3"},{"name":"toluene","range":"(5,0 – 200) µg w próbce"},{"name":"ethanol","range":"(66,7 – 3825) mg/m3"},{"name":"ethanol","range":"(120 – 2800) µg w próbce"},{"name":"1-chloro-2,3-epoksypropan","range":"(0,111 – 2,837) mg/m3"},{"name":"1-chloro-2,3-epoksypropan","range":"(0,104 – 2,128) µg w próbce"},{"name":"ethyl acetate","range":"(2,8 – 2936) mg/m3"},{"name":"ethyl acetate","range":"(30,0 – 1200) µg w próbce"},{"name":"ethyl acetate","range":"(0,77 – 804) ppm"},{"name":"4-methylpentan-2-one","range":"(2,8 – 400) mg/m3"},{"name":"4-methylpentan-2-one","range":"(5,0 – 200) µg w próbce"},{"name":"benzene","range":"(0,060 – 3,473) mg/m3"},{"name":"benzene","range":"(0,108 – 2,584) µg w próbce"},{"name":"benzene","range":"(0,02 – 1,1) ppm"},{"name":"propan-2-ol","range":"(36 – 2400) mg/m3"},{"name":"propan-2-ol","range":"(65 – 1355) µg w próbce"},{"name":"chloro(fenylo)metan","range":"(0,27–18) mg/m3"},{"name":"chloro(fenylo)metan","range":"(0,20 ÷ 9,0) µg w próbce"},{"name":"dichloromethane","range":"(2,8 – 707) mg/m3"},{"name":"dichloromethane","range":"(5,0 – 270) µg w próbce"},{"name":"dichloromethane","range":"(0,79 – 200) ppm"},{"name":"chloroform","range":"(0,78 – 40,0) mg/m3"},{"name":"chloroform","range":"(0,60 – 30,0) µg w próbce"},{"name":"phenol","range":"(0,78 – 40,0) mg/m3"},{"name":"phenol","range":"(0,50 – 30,0) µg"},{"name":"acetic acid","range":"(2,5 – 100) mg/m3"},{"name":"acetic acid","range":"(2,30 – 59,1) µg w próbce"},{"name":"acetic acid","range":"(1,0 – 40) ppm"},{"name":"pyridine","range":"(0,50 – 25,2) mg/m3"},{"name":"pyridine","range":"(0,75 – 19,1) µg w próbce"},{"name":"tetrahydrofuran","range":"(2,8 – 600) mg/m3"},{"name":"tetrahydrofuran","range":"(5,0 ÷ 225) µg"},{"name":"N,N-dimetyloformamid","range":"(0,60 – 600) mg/m3"},{"name":"N,N-dimetyloformamid","range":"(1,01 – 24,0) µg w próbce"},{"name":"N,N-dimetyloformamid","range":"(0,20 – 20) ppm"}],"search_en":"Workplace environment − air Concentration of organic substances acetone acetone methanol methanol chlorobenzene chlorobenzene toluene toluene ethanol ethanol ethyl acetate ethyl acetate ethyl acetate 4-methylpentan-2-one 4-methylpentan-2-one benzene benzene benzene propan-2-ol propan-2-ol dichloromethane dichloromethane dichloromethane chloroform chloroform phenol phenol acetic acid acetic acid acetic acid pyridine pyridine tetrahydrofuran tetrahydrofuran M/24/6/2025 wydanie 6 z dnia 04.06.2025 r.","test_object_en":"Workplace environment − air","search_zh":"工作环境 − 空气 有机物质浓度 丙酮 丙酮 甲醇 甲醇 氯苯 氯苯 甲苯 甲苯 乙醇 乙醇 乙酸乙酯 乙酸乙酯 乙酸乙酯 4-甲基-2-戊酮 4-甲基-2-戊酮 苯 苯 苯 异丙醇 异丙醇 二氯甲烷 二氯甲烷 二氯甲烷 三氯甲烷 三氯甲烷 苯酚 苯酚 乙酸 乙酸 乙酸 M/24/6/2025 wydanie 6 z dnia 04.06.2025 r.","test_object_zh":"工作环境 − 空气","parameters_zh":[{"name":"丙酮","range":"(22 – 3600) mg/m3"},{"name":"丙酮","range":"(40 – 1350) µg w próbce"},{"name":"甲醇","range":"(2,8 – 600) mg/m3"},{"name":"甲醇","range":"(5,0 – 250) µg w próbce"},{"name":"氯苯","range":"(0,9 – 140) mg/m3"},{"name":"氯苯","range":"(1,7 – 75,0) µg w próbce"},{"name":"甲苯","range":"(2,8 – 400) mg/m3"},{"name":"甲苯","range":"(5,0 – 200) µg w próbce"},{"name":"乙醇","range":"(66,7 – 3825) mg/m3"},{"name":"乙醇","range":"(120 – 2800) µg w próbce"},{"name":"1-chloro-2,3-epoksypropan","range":"(0,111 – 2,837) mg/m3"},{"name":"1-chloro-2,3-epoksypropan","range":"(0,104 – 2,128) µg w próbce"},{"name":"乙酸乙酯","range":"(2,8 – 2936) mg/m3"},{"name":"乙酸乙酯","range":"(30,0 – 1200) µg w próbce"},{"name":"乙酸乙酯","range":"(0,77 – 804) ppm"},{"name":"4-甲基-2-戊酮","range":"(2,8 – 400) mg/m3"},{"name":"4-甲基-2-戊酮","range":"(5,0 – 200) µg w próbce"},{"name":"苯","range":"(0,060 – 3,473) mg/m3"},{"name":"苯","range":"(0,108 – 2,584) µg w próbce"},{"name":"苯","range":"(0,02 – 1,1) ppm"},{"name":"异丙醇","range":"(36 – 2400) mg/m3"},{"name":"异丙醇","range":"(65 – 1355) µg w próbce"},{"name":"chloro(fenylo)metan","range":"(0,27–18) mg/m3"},{"name":"chloro(fenylo)metan","range":"(0,20 ÷ 9,0) µg w próbce"},{"name":"二氯甲烷","range":"(2,8 – 707) mg/m3"},{"name":"二氯甲烷","range":"(5,0 – 270) µg w próbce"},{"name":"二氯甲烷","range":"(0,79 – 200) ppm"},{"name":"三氯甲烷","range":"(0,78 – 40,0) mg/m3"},{"name":"三氯甲烷","range":"(0,60 – 30,0) µg w próbce"},{"name":"苯酚","range":"(0,78 – 40,0) mg/m3"},{"name":"苯酚","range":"(0,50 – 30,0) µg"},{"name":"乙酸","range":"(2,5 – 100) mg/m3"},{"name":"乙酸","range":"(2,30 – 59,1) µg w próbce"},{"name":"乙酸","range":"(1,0 – 40) ppm"},{"name":"pirydyna","range":"(0,50 – 25,2) mg/m3"},{"name":"pirydyna","range":"(0,75 – 19,1) µg w próbce"},{"name":"tetrahydrofuran","range":"(2,8 – 600) mg/m3"},{"name":"tetrahydrofuran","range":"(5,0 ÷ 225) µg"},{"name":"N,N-dimetyloformamid","range":"(0,60 – 600) mg/m3"},{"name":"N,N-dimetyloformamid","range":"(1,01 – 24,0) µg w próbce"},{"name":"N,N-dimetyloformamid","range":"(0,20 – 20) ppm"}],"methodology_zh":"有机物质浓度"}],"has_pdf":true}