{"lab":{"_id":"69ad52a3de79e566650fb566","accr_number":"AB 1063","country":"PL","accr_body":"PCA","address":"ul. Targowa 16, 74-100 Gryfino, LABORATORIUM, ul. Łączna 1 AA","categories":["water","microbiology"],"city":"Gryfino","imported_at":"2026-03-08T10:42:43.265Z","methods_count":46,"name":"PRZEDSIĘBIORSTWO USŁUG KOMUNALNYCH Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1063.pdf"],"scope_summary":"","search_text":"przedsiębiorstwo usług komunalnych sp. z o.o. ul. targowa 16, 74-100 gryfino, laboratorium, ul. łączna 1 aa water other pharma metrology electronics microbiology","status":"active","updated_at":"2026-03-08T14:50:14.659Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-14T12:36:39.606Z","parse_date":"2026-08-14T12:36:39.606Z","parse_source":"agent-claude-code","email_confidence":"high","email_mx":true,"email_source":"https://pukgryfino.pl/strona/dane-teleadresowe","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P; C/32/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, osadów","en":"Chemical tests and sampling of water, drinking water, sewage, sediments"},{"codes":"K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody do spożycia przez ludzi","en":"Microbiological tests and sampling of drinking water"},{"codes":"N/28/P; N/29/P; N/30/P; N/32/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, osadów","en":"Tests of physical properties and sampling of water, drinking water, sediments, sewage"}],"issue":{"no":"20","date":"22.06.2026"},"map_coord":[53.258137,14.485913],"map_geo":"nominatim-street","lab_locations":[{"name":"Pracownia Badań Fizyko-Chemicznych","address":"ul. Łączna 1 AA, 74-100 Gryfino","city":"Gryfino","postal":"74-100"},{"name":"Pracownia Badań Mikrobiologicznych","address":"ul. Łączna 1 AA, 74-100 Gryfino","city":"Gryfino","postal":"74-100"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/14/61556488e88c8e5787eb21844dbb2b38/AB%201063.pdf","has_en":true,"category_counts":{"water":46,"microbiology":4},"category_scores":{"water":42.32,"microbiology":0.32},"has_zh":true},"methods":[{"_id":"6a7f0bd71995264369d8e2c1","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura pobranej próbki ścieków","range":"(5 – 35) 0C"}],"technique":"Metoda manualna i automatyczna","techniques":["Metoda manualna i automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nTemperatura pobranej próbki ścieków (5 – 35) 0C\nMetoda manualna i automatyczna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nTemperatura pobranej próbki ścieków (5 – 35) 0C\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych\nTemperatura pobranej probki sciekow (5 – 35) 0C\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature of the collected wastewater sample","range":"(5 – 35) 0C"}],"search_en":"Wastewater Sampling for chemical and physical testing Manual and automatic method Temperature of the collected wastewater sample PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_en":"Manual and automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手工与自动法 所采废水样品的温度 PN-ISO 5667-10:2021-11 | PN-77/C-04584","test_object_zh":"污水","parameters_zh":[{"name":"所采废水样品的温度","range":"(5 – 35) 0C"}],"technique_zh":"手工与自动法"},{"_id":"6a7f0bd71995264369d8e2c2","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,05 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,05 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (0,05 – 100) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Scieki Stezenie azotu amonowego\nZakres (0,05 – 100) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,05 – 100) mg/l"}],"search_en":"Wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 100) mg/l"}],"search_zh":"污水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7f0bd71995264369d8e2c3","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Stężenie azotu amonowego","range":"(0,07 – 232) mg/l"},{"name":"Stężenie jonów amonowych","range":"(0,10 – 300) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres:\nStężenie azotu amonowego (0,07 – 232) mg/l\nStężenie jonów amonowych (0,10 – 300) mg/l\nMetoda spektrofotometryczna","reference":"PB-07.00 wydanie 4 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 304; LCK 305; LCK 302","norm_bases":["PB-07.00 wydanie 4 z dnia 17.12.2015 r.","na podstawie testu HACH LANGE LCK 304; LCK 305; LCK 302"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres:\nStężenie azotu amonowego (0,07 – 232) mg/l\nStężenie jonów amonowych (0,10 – 300) mg/l\nMetoda spektrofotometryczna PB-07.00 wydanie 4 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 304; LCK 305; LCK 302 Scieki Stezenie azotu amonowego\nZakres:\nStezenie azotu amonowego (0,07 – 232) mg/l\nStezenie jonow amonowych (0,10 – 300) mg/l\nMetoda spektrofotometryczna PB-07.00 wydanie 4 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 304; LCK 305; LCK 302","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Ammonium nitrogen concentration","range":"(0,07 – 232) mg/l"},{"name":"Ammonium ion concentration","range":"(0,10 – 300) mg/l"}],"search_en":"Wastewater Ammonium nitrogen concentration Spectrophotometric method Ammonium nitrogen concentration Ammonium ion concentration PB-07.00 wydanie 4 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 304; LCK 305; LCK 302","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"氨氮浓度","range":"(0,07 – 232) mg/l"},{"name":"铵离子浓度","range":"(0,10 – 300) mg/l"}],"search_zh":"污水 氨氮浓度 分光光度法 氨氮浓度 铵离子浓度 PB-07.00 wydanie 4 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 304; LCK 305; LCK 302","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7f0bd71995264369d8e2c4","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(5,0 – 200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (5,0 – 200) mg/l\nMetoda spektrofotometryczna","reference":"PB-01.00 Wydanie 7 z dnia 13.12.2017 r. | na podstawie testu HACH LANGE LCK 238; LCK 338","norm_bases":["PB-01.00 Wydanie 7 z dnia 13.12.2017 r.","na podstawie testu HACH LANGE LCK 238; LCK 338"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego\nZakres (5,0 – 200) mg/l\nMetoda spektrofotometryczna PB-01.00 Wydanie 7 z dnia 13.12.2017 r. | na podstawie testu HACH LANGE LCK 238; LCK 338 Scieki Stezenie azotu ogolnego\nZakres (5,0 – 200) mg/l\nMetoda spektrofotometryczna PB-01.00 Wydanie 7 z dnia 13.12.2017 r. | na podstawie testu HACH LANGE LCK 238; LCK 338","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(5,0 – 200) mg/l"}],"search_en":"Wastewater Total nitrogen concentration Spectrophotometric method Range PB-01.00 Wydanie 7 z dnia 13.12.2017 r. | na podstawie testu HACH LANGE LCK 238; LCK 338","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 200) mg/l"}],"search_zh":"污水 总氮浓度 分光光度法 范围 PB-01.00 Wydanie 7 z dnia 13.12.2017 r. | na podstawie testu HACH LANGE LCK 238; LCK 338","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7f0bd71995264369d8e2c5","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu -BZT5","parameters":[{"name":"Zakres","range":"(0,50 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu -BZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu -BZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Scieki Biochemiczne zapotrzebowanie tlenu -BZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand -BOD5","parameters_en":[{"name":"Range","range":"(0,50 – 6,0) mg/l O2"}],"search_en":"Wastewater Biochemical oxygen demand -BOD5 Electrochemical method Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,50 – 6,0) mg/l O2"}],"search_zh":"污水 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"污水"},{"_id":"6a7f0bd71995264369d8e2c6","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu -BZT5","parameters":[{"name":"Zakres","range":"(6 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu -BZT5\nZakres (6 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu -BZT5\nZakres (6 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu -BZT5\nZakres (6 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand -BOD5","parameters_en":[{"name":"Range","range":"(6 – 6000) mg/l O2"}],"search_en":"Wastewater Biochemical oxygen demand -BOD5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(6 – 6000) mg/l O2"}],"search_zh":"污水 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"污水"},{"_id":"6a7f0bd71995264369d8e2c7","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr","parameters":[{"name":"Zakres","range":"(15 – 5000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (15 – 5000) mg/l O2\nMetoda spektrofotometryczna","reference":"PB-03.00 wydanie 5 z dnia 17.12.2015 r | na podstawie testu HACH LANGE LCK 314; LCK 514; LCK 014; LCK 1014","norm_bases":["PB-03.00 wydanie 5 z dnia 17.12.2015 r","na podstawie testu HACH LANGE LCK 314; LCK 514; LCK 014; LCK 1014"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (15 – 5000) mg/l O2\nMetoda spektrofotometryczna PB-03.00 wydanie 5 z dnia 17.12.2015 r | na podstawie testu HACH LANGE LCK 314; LCK 514; LCK 014; LCK 1014 Scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (15 – 5000) mg/l O2\nMetoda spektrofotometryczna PB-03.00 wydanie 5 z dnia 17.12.2015 r | na podstawie testu HACH LANGE LCK 314; LCK 514; LCK 014; LCK 1014","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand - COD-Cr","parameters_en":[{"name":"Range","range":"(15 – 5000) mg/l O2"}],"search_en":"Wastewater Chemical oxygen demand - COD-Cr Spectrophotometric method Range PB-03.00 wydanie 5 z dnia 17.12.2015 r | na podstawie testu HACH LANGE LCK 314; LCK 514; LCK 014; LCK 1014","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(15 – 5000) mg/l O2"}],"search_zh":"污水 化学需氧量（COD-Cr） 分光光度法 范围 PB-03.00 wydanie 5 z dnia 17.12.2015 r | na podstawie testu HACH LANGE LCK 314; LCK 514; LCK 014; LCK 1014","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a7f0bd71995264369d8e2c8","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu (SP-ChZT)","parameters":[{"name":"Zakres","range":"(15,0 – 5000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu (SP-ChZT)\nZakres (15,0 – 5000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu (SP-ChZT)\nZakres (15,0 – 5000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu (SP-ChZT)\nZakres (15,0 – 5000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand (SP-COD)","parameters_en":[{"name":"Range","range":"(15,0 – 5000) mg/l O2"}],"search_en":"Wastewater Chemical oxygen demand (SP-COD) Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(15,0 – 5000) mg/l O2"}],"search_zh":"污水 化学需氧量（SP-COD） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"化学需氧量（SP-COD）"},{"_id":"6a7f0bd71995264369d8e2c9","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Stężenie fosforu ogólnego","range":"(0,32 – 19,5) mg/l"},{"name":"Stężenie ortofosforanów","range":"(1,00 – 60) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres:\nStężenie fosforu ogólnego (0,32 – 19,5) mg/l\nStężenie ortofosforanów (1,00 – 60) mg/l\nMetoda spektrofotometryczna","reference":"PB-04.00 wydanie 5 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 348; LCK 350","norm_bases":["PB-04.00 wydanie 5 z dnia 17.12.2015 r.","na podstawie testu HACH LANGE LCK 348; LCK 350"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres:\nStężenie fosforu ogólnego (0,32 – 19,5) mg/l\nStężenie ortofosforanów (1,00 – 60) mg/l\nMetoda spektrofotometryczna PB-04.00 wydanie 5 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 348; LCK 350 Scieki Stezenie fosforu ogolnego\nZakres:\nStezenie fosforu ogolnego (0,32 – 19,5) mg/l\nStezenie ortofosforanow (1,00 – 60) mg/l\nMetoda spektrofotometryczna PB-04.00 wydanie 5 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 348; LCK 350","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Total phosphorus concentration","range":"(0,32 – 19,5) mg/l"},{"name":"Orthophosphate concentration","range":"(1,00 – 60) mg/l"}],"search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Total phosphorus concentration Orthophosphate concentration PB-04.00 wydanie 5 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 348; LCK 350","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"总磷浓度","range":"(0,32 – 19,5) mg/l"},{"name":"正磷酸盐浓度","range":"(1,00 – 60) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 总磷浓度 正磷酸盐浓度 PB-04.00 wydanie 5 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 348; LCK 350","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7f0bd71995264369d8e2ca","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,06 – 19,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,06 – 19,5) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6878:2006 +Ap1:2010+Ap2:2010 pkt. 7","norm_bases":["PN-ISO 6878:2006 +Ap1:2010+Ap2:2010 pkt. 7"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,06 – 19,5) mg/l\nMetoda spektrofotometryczna PN-ISO 6878:2006 +Ap1:2010+Ap2:2010 pkt. 7 Scieki Stezenie fosforu ogolnego\nZakres (0,06 – 19,5) mg/l\nMetoda spektrofotometryczna PN-ISO 6878:2006 +Ap1:2010+Ap2:2010 pkt. 7","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,06 – 19,5) mg/l"}],"search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Range PN-ISO 6878:2006 +Ap1:2010+Ap2:2010 pkt. 7","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,06 – 19,5) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 范围 PN-ISO 6878:2006 +Ap1:2010+Ap2:2010 pkt. 7","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7f0bd71995264369d8e2cb","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,20 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,20 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PB-17.00 wydanie 2 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 321","norm_bases":["PB-17.00 wydanie 2 z dnia 17.12.2015 r.","na podstawie testu HACH LANGE LCK 321"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie żelaza ogólnego\nZakres (0,20 – 100) mg/l\nMetoda spektrofotometryczna PB-17.00 wydanie 2 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 321 Scieki Stezenie zelaza ogolnego\nZakres (0,20 – 100) mg/l\nMetoda spektrofotometryczna PB-17.00 wydanie 2 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 321","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,20 – 100) mg/l"}],"search_en":"Wastewater Total iron concentration Spectrophotometric method Range PB-17.00 wydanie 2 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 321","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 100) mg/l"}],"search_zh":"污水 总铁浓度 分光光度法 范围 PB-17.00 wydanie 2 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 321","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7f0bd71995264369d8e2cc","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(40 – 500) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczanów\nZakres (40 – 500) mg/l\nMetoda spektrofotometryczna","reference":"PB-05.00 wydanie 5 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 153; LCK 353","norm_bases":["PB-05.00 wydanie 5 z dnia 17.12.2015 r.","na podstawie testu HACH LANGE LCK 153; LCK 353"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie siarczanów\nZakres (40 – 500) mg/l\nMetoda spektrofotometryczna PB-05.00 wydanie 5 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 153; LCK 353 Scieki Stezenie siarczanow\nZakres (40 – 500) mg/l\nMetoda spektrofotometryczna PB-05.00 wydanie 5 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 153; LCK 353","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(40 – 500) mg/l"}],"search_en":"Wastewater Sulfate concentration Spectrophotometric method Range PB-05.00 wydanie 5 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 153; LCK 353","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(40 – 500) mg/l"}],"search_zh":"污水 硫酸盐浓度 分光光度法 范围 PB-05.00 wydanie 5 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 153; LCK 353","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7f0bd71995264369d8e2cd","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(5,0 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (5,0 – 5000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Zawiesiny ogólne\nZakres (5,0 – 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne\nZakres (5,0 – 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(5,0 – 5000) mg/l"}],"search_en":"Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(5,0 – 5000) mg/l"}],"search_zh":"污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a7f0bd71995264369d8e2ce","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie anionowych substancji powierzchniowo-czynnych","parameters":[{"name":"Zakres","range":"(0,10 – 40,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie anionowych substancji powierzchniowo-czynnych\nZakres (0,10 – 40,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-19.00 wydanie 3 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 332","norm_bases":["PB-19.00 wydanie 3 z dnia 17.12.2015 r.","na podstawie testu HACH LANGE LCK 332"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie anionowych substancji powierzchniowo-czynnych\nZakres (0,10 – 40,0) mg/l\nMetoda spektrofotometryczna PB-19.00 wydanie 3 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 332 Scieki Stezenie anionowych substancji powierzchniowo-czynnych\nZakres (0,10 – 40,0) mg/l\nMetoda spektrofotometryczna PB-19.00 wydanie 3 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 332","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anionic surfactants concentration","parameters_en":[{"name":"Range","range":"(0,10 – 40,0) mg/l"}],"search_en":"Wastewater Anionic surfactants concentration Spectrophotometric method Range PB-19.00 wydanie 3 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 332","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,10 – 40,0) mg/l"}],"search_zh":"污水 分光光度法 范围 PB-19.00 wydanie 3 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 332","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7f0bd71995264369d8e2cf","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie niejonowych substancji powierzchniowo-czynnych","parameters":[{"name":"Zakres","range":"(0,20 – 80) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie niejonowych substancji powierzchniowo-czynnych\nZakres (0,20 – 80) mg/l\nMetoda spektrofotometryczna","reference":"PB-16.00 wydanie 2 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 333","norm_bases":["PB-16.00 wydanie 2 z dnia 17.12.2015 r.","na podstawie testu HACH LANGE LCK 333"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie niejonowych substancji powierzchniowo-czynnych\nZakres (0,20 – 80) mg/l\nMetoda spektrofotometryczna PB-16.00 wydanie 2 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 333 Scieki Stezenie niejonowych substancji powierzchniowo-czynnych\nZakres (0,20 – 80) mg/l\nMetoda spektrofotometryczna PB-16.00 wydanie 2 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 333","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of non-ionic surfactants","parameters_en":[{"name":"Range","range":"(0,20 – 80) mg/l"}],"search_en":"Wastewater Concentration of non-ionic surfactants Spectrophotometric method Range PB-16.00 wydanie 2 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 333","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,20 – 80) mg/l"}],"search_zh":"污水 分光光度法 范围 PB-16.00 wydanie 2 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 333","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7f0bd71995264369d8e2d0","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,23 – 13,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,23 – 13,5) mg/l\nMetoda spektrofotometryczna","reference":"PB-21.00 wydanie 2 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 339","norm_bases":["PB-21.00 wydanie 2 z dnia 17.12.2015 r.","na podstawie testu HACH LANGE LCK 339"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotanowego\nZakres (0,23 – 13,5) mg/l\nMetoda spektrofotometryczna PB-21.00 wydanie 2 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 339 Scieki Stezenie azotu azotanowego\nZakres (0,23 – 13,5) mg/l\nMetoda spektrofotometryczna PB-21.00 wydanie 2 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 339","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,23 – 13,5) mg/l"}],"search_en":"Wastewater Nitrate nitrogen concentration Spectrophotometric method Range PB-21.00 wydanie 2 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 339","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,23 – 13,5) mg/l"}],"search_zh":"污水 硝态氮浓度 分光光度法 范围 PB-21.00 wydanie 2 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 339","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7f0bd71995264369d8e2d1","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,15 – 0,60) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,15 – 0,60) mg/l\nMetoda spektrofotometryczna","reference":"PB-22.00 wydanie 2 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 341","norm_bases":["PB-22.00 wydanie 2 z dnia 17.12.2015 r.","na podstawie testu HACH LANGE LCK 341"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotynowego\nZakres (0,15 – 0,60) mg/l\nMetoda spektrofotometryczna PB-22.00 wydanie 2 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 341 Scieki Stezenie azotu azotynowego\nZakres (0,15 – 0,60) mg/l\nMetoda spektrofotometryczna PB-22.00 wydanie 2 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 341","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,15 – 0,60) mg/l"}],"search_en":"Wastewater Nitrite nitrogen concentration Spectrophotometric method Range PB-22.00 wydanie 2 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 341","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,15 – 0,60) mg/l"}],"search_zh":"污水 亚硝态氮浓度 分光光度法 范围 PB-22.00 wydanie 2 z dnia 17.12.2015 r. | na podstawie testu HACH LANGE LCK 341","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7f0bd71995264369d8e2d2","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,1 – 40) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,1 – 40) mg/l\nMetoda spektrofotometryczna","reference":"PN ISO 6332:2001 pkt. 7.1.1","norm_bases":["PN ISO 6332:2001 pkt. 7.1.1"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie żelaza ogólnego\nZakres (0,1 – 40) mg/l\nMetoda spektrofotometryczna PN ISO 6332:2001 pkt. 7.1.1 Scieki Stezenie zelaza ogolnego\nZakres (0,1 – 40) mg/l\nMetoda spektrofotometryczna PN ISO 6332:2001 pkt. 7.1.1","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,1 – 40) mg/l"}],"search_en":"Wastewater Total iron concentration Spectrophotometric method Range PN ISO 6332:2001 pkt. 7.1.1","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,1 – 40) mg/l"}],"search_zh":"污水 总铁浓度 分光光度法 范围 PN ISO 6332:2001 pkt. 7.1.1","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7f0bd71995264369d8e2d3","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Ścieki, woda do spożycia przez ludzi","methodology":"pH + Badania wykonywane w siedzibie i poza siedzibą laboratorium","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH + Badania wykonywane w siedzibie i poza siedzibą laboratorium\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda do spożycia przez ludzi pH + Badania wykonywane w siedzibie i poza siedzibą laboratorium\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki, woda do spozycia przez ludzi pH + Badania wykonywane w siedzibie i poza siedziba laboratorium\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Wastewater, water intended for human consumption Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Wastewater, water intended for human consumption","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"废水、生活饮用水 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"废水、生活饮用水"},{"_id":"6a7f0bd71995264369d8e2d4","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Ścieki, woda do spożycia przez ludzi","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda do spożycia przez ludzi Stężenie chlorków\nZakres (5,0 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki, woda do spozycia przez ludzi Stezenie chlorkow\nZakres (5,0 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 1000) mg/l"}],"search_en":"Wastewater, water intended for human consumption Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Wastewater, water intended for human consumption","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 1000) mg/l"}],"search_zh":"废水、生活饮用水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"废水、生活饮用水"},{"_id":"6a7f0bd71995264369d8e2d5","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Ścieki, woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa + Badania wykonywane w siedzibie i poza siedzibą laboratorium","parameters":[{"name":"Zakres","range":"(500 – 12900) µS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa + Badania wykonywane w siedzibie i poza siedzibą laboratorium\nZakres (500 – 12900) µS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda do spożycia przez ludzi Przewodność elektryczna właściwa + Badania wykonywane w siedzibie i poza siedzibą laboratorium\nZakres (500 – 12900) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Scieki, woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa + Badania wykonywane w siedzibie i poza siedziba laboratorium\nZakres (500 – 12900) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(500 – 12900) µS/cm"}],"search_en":"Wastewater, water intended for human consumption Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Wastewater, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(500 – 12900) µS/cm"}],"search_zh":"废水、生活饮用水 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"废水、生活饮用水"},{"_id":"6a7f0bd71995264369d8e2d6","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Ścieki, woda do spożycia przez ludzi","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10,0 – 500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10,0 – 500) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda do spożycia przez ludzi Stężenie siarczanów\nZakres (10,0 – 500) mg/l\nMetoda wagowa PN-ISO 9280:2002 Scieki, woda do spozycia przez ludzi Stezenie siarczanow\nZakres (10,0 – 500) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10,0 – 500) mg/l"}],"search_en":"Wastewater, water intended for human consumption Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Wastewater, water intended for human consumption","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10,0 – 500) mg/l"}],"search_zh":"废水、生活饮用水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"废水、生活饮用水"},{"_id":"6a7f0bd71995264369d8e2d7","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Osady ściekowe, osad czynny","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-13:2011","norm_bases":["PN-EN ISO 5667-13:2011"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe, osad czynny Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-13:2011 Osady sciekowe, osad czynny Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-13:2011","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Sewage sludge, activated sludge Sampling for chemical and physical testing PN-EN ISO 5667-13:2011","test_object_en":"Sewage sludge, activated sludge","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水污泥、活性污泥 化学与物理检测用样品采集 PN-EN ISO 5667-13:2011","test_object_zh":"污水污泥、活性污泥"},{"_id":"6a7f0bd71995264369d8e2d8","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Osady ściekowe, osad czynny","methodology":"pH","parameters":[{"name":"Zakres","range":"(4,0 – 10,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (4,0 – 10,0)\nMetoda potencjometryczna","reference":"PN-EN 12176:2004","norm_bases":["PN-EN 12176:2004"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe, osad czynny pH\nZakres (4,0 – 10,0)\nMetoda potencjometryczna PN-EN 12176:2004 Osady sciekowe, osad czynny pH\nZakres (4,0 – 10,0)\nMetoda potencjometryczna PN-EN 12176:2004","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"(4,0 – 10,0)"}],"search_en":"Sewage sludge, activated sludge pH Potentiometric method Range PN-EN 12176:2004","technique_en":"Potentiometric method","test_object_en":"Sewage sludge, activated sludge","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(4,0 – 10,0)"}],"search_zh":"污水污泥、活性污泥 pH 值 电位法 范围 PN-EN 12176:2004","technique_zh":"电位法","test_object_zh":"污水污泥、活性污泥"},{"_id":"6a7f0bd71995264369d8e2d9","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Osady ściekowe, osad czynny","methodology":"Sucha pozostałość/ zawartość wody","parameters":[{"name":"Zakres","range":"(1,0 – 50) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość/ zawartość wody\nZakres (1,0 – 50) %\nMetoda wagowa","reference":"PN-EN 12880:2004","norm_bases":["PN-EN 12880:2004"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe, osad czynny Sucha pozostałość/ zawartość wody\nZakres (1,0 – 50) %\nMetoda wagowa PN-EN 12880:2004 Osady sciekowe, osad czynny Sucha pozostalosc/ zawartosc wody\nZakres (1,0 – 50) %\nMetoda wagowa PN-EN 12880:2004","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(1,0 – 50) %"}],"search_en":"Sewage sludge, activated sludge Gravimetric method Range PN-EN 12880:2004","technique_en":"Gravimetric method","test_object_en":"Sewage sludge, activated sludge","parameters_zh":[{"name":"范围","range":"(1,0 – 50) %"}],"search_zh":"污水污泥、活性污泥 重量法 范围 PN-EN 12880:2004","technique_zh":"重量法","test_object_zh":"污水污泥、活性污泥"},{"_id":"6a7f0bd71995264369d8e2da","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Osad czynny","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2000 – 10000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2000 – 10000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osad czynny Zawiesiny ogólne\nZakres (2000 – 10000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Osad czynny Zawiesiny ogolne\nZakres (2000 – 10000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2000 – 10000) mg/l"}],"search_en":"Activated sludge Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Activated sludge","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2000 – 10000) mg/l"}],"search_zh":"活性污泥 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"活性污泥"},{"_id":"6a7f0bd71995264369d8e2db","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10 z wyłączeniem pkt. 6.5","norm_bases":["PN-ISO 5667-5:2017-10 z wyłączeniem pkt. 6.5"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 z wyłączeniem pkt. 6.5 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10 z wylaczeniem pkt. 6.5","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10 z wyłączeniem pkt. 6.5","test_object_en":"Water intended for human consumption","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 PN-ISO 5667-5:2017-10 z wyłączeniem pkt. 6.5","test_object_zh":"生活饮用水"},{"_id":"6a7f0bd71995264369d8e2dc","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(40 – 500) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczanów\nZakres (40 – 500) mg/l\nMetoda spektrofotometryczna","reference":"PB-08.00 wydanie 4 z dnia 09.07.2020 r. | na podstawie testu HACH LANGE LCK 153; LCK 353","norm_bases":["PB-08.00 wydanie 4 z dnia 09.07.2020 r.","na podstawie testu HACH LANGE LCK 153; LCK 353"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie siarczanów\nZakres (40 – 500) mg/l\nMetoda spektrofotometryczna PB-08.00 wydanie 4 z dnia 09.07.2020 r. | na podstawie testu HACH LANGE LCK 153; LCK 353 Woda do spozycia przez ludzi Stezenie siarczanow\nZakres (40 – 500) mg/l\nMetoda spektrofotometryczna PB-08.00 wydanie 4 z dnia 09.07.2020 r. | na podstawie testu HACH LANGE LCK 153; LCK 353","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(40 – 500) mg/l"}],"search_en":"Water intended for human consumption Sulfate concentration Spectrophotometric method Range PB-08.00 wydanie 4 z dnia 09.07.2020 r. | na podstawie testu HACH LANGE LCK 153; LCK 353","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(40 – 500) mg/l"}],"search_zh":"生活饮用水 硫酸盐浓度 分光光度法 范围 PB-08.00 wydanie 4 z dnia 09.07.2020 r. | na podstawie testu HACH LANGE LCK 153; LCK 353","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a7f0bd71995264369d8e2dd","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,05 – 2,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,05 – 2,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,05 – 2,00) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,05 – 2,00) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,05 – 2,00) mg/l"}],"search_en":"Water intended for human consumption Ammonium ion concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 2,00) mg/l"}],"search_zh":"生活饮用水 铵离子浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a7f0bd71995264369d8e2de","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie jonów amonowych","parameters":[{"name":"Zakres","range":"(0,10 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonów amonowych\nZakres (0,10 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-09.00 wydanie 4 z dnia 09.07.2020 r. | na podstawie testu HACH LANGE LCK 304","norm_bases":["PB-09.00 wydanie 4 z dnia 09.07.2020 r.","na podstawie testu HACH LANGE LCK 304"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie jonów amonowych\nZakres (0,10 – 2,0) mg/l\nMetoda spektrofotometryczna PB-09.00 wydanie 4 z dnia 09.07.2020 r. | na podstawie testu HACH LANGE LCK 304 Woda do spozycia przez ludzi Stezenie jonow amonowych\nZakres (0,10 – 2,0) mg/l\nMetoda spektrofotometryczna PB-09.00 wydanie 4 z dnia 09.07.2020 r. | na podstawie testu HACH LANGE LCK 304","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,10 – 2,0) mg/l"}],"search_en":"Water intended for human consumption Ammonium ion concentration Spectrophotometric method Range PB-09.00 wydanie 4 z dnia 09.07.2020 r. | na podstawie testu HACH LANGE LCK 304","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,10 – 2,0) mg/l"}],"search_zh":"生活饮用水 铵离子浓度 分光光度法 范围 PB-09.00 wydanie 4 z dnia 09.07.2020 r. | na podstawie testu HACH LANGE LCK 304","technique_zh":"分光光度法","test_object_zh":"生活饮用水","methodology_zh":"铵离子浓度"},{"_id":"6a7f0bd71995264369d8e2df","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,15 – 0,75) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,15 – 0,75) mg/l\nMetoda kolorymetryczna","reference":"PB-10.00 wydanie 4 z dnia 09.07.2020 r. | na podstawie metody HACH LANGE","norm_bases":["PB-10.00 wydanie 4 z dnia 09.07.2020 r.","na podstawie metody HACH LANGE"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie chloru wolnego\nZakres (0,15 – 0,75) mg/l\nMetoda kolorymetryczna PB-10.00 wydanie 4 z dnia 09.07.2020 r. | na podstawie metody HACH LANGE Woda do spozycia przez ludzi Stezenie chloru wolnego\nZakres (0,15 – 0,75) mg/l\nMetoda kolorymetryczna PB-10.00 wydanie 4 z dnia 09.07.2020 r. | na podstawie metody HACH LANGE","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,15 – 0,75) mg/l"}],"search_en":"Water intended for human consumption Free chlorine concentration Colorimetric method Range PB-10.00 wydanie 4 z dnia 09.07.2020 r. | na podstawie metody HACH LANGE","technique_en":"Colorimetric method","test_object_en":"Water intended for human consumption","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,15 – 0,75) mg/l"}],"search_zh":"生活饮用水 游离氯浓度 比色法 范围 PB-10.00 wydanie 4 z dnia 09.07.2020 r. | na podstawie metody HACH LANGE","technique_zh":"比色法","test_object_zh":"生活饮用水"},{"_id":"6a7f0bd71995264369d8e2e0","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(1,00 – 55) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (1,00 – 55) mg/l\nMetoda spektrofotometryczna","reference":"PB-11.00 wydanie 5 z dnia 09.07.2020 r. | na podstawie testu HACH LANGE LCK 339","norm_bases":["PB-11.00 wydanie 5 z dnia 09.07.2020 r.","na podstawie testu HACH LANGE LCK 339"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie azotanów\nZakres (1,00 – 55) mg/l\nMetoda spektrofotometryczna PB-11.00 wydanie 5 z dnia 09.07.2020 r. | na podstawie testu HACH LANGE LCK 339 Woda do spozycia przez ludzi Stezenie azotanow\nZakres (1,00 – 55) mg/l\nMetoda spektrofotometryczna PB-11.00 wydanie 5 z dnia 09.07.2020 r. | na podstawie testu HACH LANGE LCK 339","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(1,00 – 55) mg/l"}],"search_en":"Water intended for human consumption Nitrate concentration Spectrophotometric method Range PB-11.00 wydanie 5 z dnia 09.07.2020 r. | na podstawie testu HACH LANGE LCK 339","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(1,00 – 55) mg/l"}],"search_zh":"生活饮用水 硝酸盐浓度 分光光度法 范围 PB-11.00 wydanie 5 z dnia 09.07.2020 r. | na podstawie testu HACH LANGE LCK 339","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a7f0bd71995264369d8e2e1","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,020 – 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,020 – 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-12.00 wydanie 4 z dnia 14.07.2020 r. | na podstawie testu HACH LANGE LCK 341","norm_bases":["PB-12.00 wydanie 4 z dnia 14.07.2020 r.","na podstawie testu HACH LANGE LCK 341"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,020 – 1,0) mg/l\nMetoda spektrofotometryczna PB-12.00 wydanie 4 z dnia 14.07.2020 r. | na podstawie testu HACH LANGE LCK 341 Woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,020 – 1,0) mg/l\nMetoda spektrofotometryczna PB-12.00 wydanie 4 z dnia 14.07.2020 r. | na podstawie testu HACH LANGE LCK 341","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,020 – 1,0) mg/l"}],"search_en":"Water intended for human consumption Nitrite concentration Spectrophotometric method Range PB-12.00 wydanie 4 z dnia 14.07.2020 r. | na podstawie testu HACH LANGE LCK 341","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,020 – 1,0) mg/l"}],"search_zh":"生活饮用水 亚硝酸盐浓度 分光光度法 范围 PB-12.00 wydanie 4 z dnia 14.07.2020 r. | na podstawie testu HACH LANGE LCK 341","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a7f0bd71995264369d8e2e2","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(10 – 5000) µg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (10 – 5000) µg/l\nMetoda spektrofotometryczna","reference":"PB-13.00 wydanie 4 z dnia 14.07.2020 r. | na podstawie testu HACH LANGE LCK 521","norm_bases":["PB-13.00 wydanie 4 z dnia 14.07.2020 r.","na podstawie testu HACH LANGE LCK 521"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie żelaza\nZakres (10 – 5000) µg/l\nMetoda spektrofotometryczna PB-13.00 wydanie 4 z dnia 14.07.2020 r. | na podstawie testu HACH LANGE LCK 521 Woda do spozycia przez ludzi Stezenie zelaza\nZakres (10 – 5000) µg/l\nMetoda spektrofotometryczna PB-13.00 wydanie 4 z dnia 14.07.2020 r. | na podstawie testu HACH LANGE LCK 521","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(10 – 5000) µg/l"}],"search_en":"Water intended for human consumption Iron concentration Spectrophotometric method Range PB-13.00 wydanie 4 z dnia 14.07.2020 r. | na podstawie testu HACH LANGE LCK 521","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(10 – 5000) µg/l"}],"search_zh":"生活饮用水 铁浓度 分光光度法 范围 PB-13.00 wydanie 4 z dnia 14.07.2020 r. | na podstawie testu HACH LANGE LCK 521","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a7f0bd71995264369d8e2e3","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(20 – 1000) µg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (20 – 1000) µg/l\nMetoda spektrofotometryczna","reference":"PB-14.00 wydanie 4 z dnia 14.07.2020 r. | na podstawie testu HACH LANGE LCW 032","norm_bases":["PB-14.00 wydanie 4 z dnia 14.07.2020 r.","na podstawie testu HACH LANGE LCW 032"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie manganu\nZakres (20 – 1000) µg/l\nMetoda spektrofotometryczna PB-14.00 wydanie 4 z dnia 14.07.2020 r. | na podstawie testu HACH LANGE LCW 032 Woda do spozycia przez ludzi Stezenie manganu\nZakres (20 – 1000) µg/l\nMetoda spektrofotometryczna PB-14.00 wydanie 4 z dnia 14.07.2020 r. | na podstawie testu HACH LANGE LCW 032","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(20 – 1000) µg/l"}],"search_en":"Water intended for human consumption Manganese concentration Spectrophotometric method Range PB-14.00 wydanie 4 z dnia 14.07.2020 r. | na podstawie testu HACH LANGE LCW 032","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(20 – 1000) µg/l"}],"search_zh":"生活饮用水 锰浓度 分光光度法 范围 PB-14.00 wydanie 4 z dnia 14.07.2020 r. | na podstawie testu HACH LANGE LCW 032","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a7f0bd71995264369d8e2e4","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Twardość ogólna","parameters":[{"name":"Zakres","range":"(1,00 – 55,8) O dH"},{"name":"Zakres","range":"(17,9 – 1000) mg/l CaCO3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Twardość ogólna\nZakres:\nZakres (1,00 – 55,8) O dH\nZakres (17,9 – 1000) mg/l CaCO3\nMetoda spektrofotometryczna","reference":"PB-15.00 wydanie 4 z dnia 14.07.2020 r. | na podstawie testu HACH LANGE LCK 327","norm_bases":["PB-15.00 wydanie 4 z dnia 14.07.2020 r.","na podstawie testu HACH LANGE LCK 327"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Twardość ogólna\nZakres:\nZakres (1,00 – 55,8) O dH\nZakres (17,9 – 1000) mg/l CaCO3\nMetoda spektrofotometryczna PB-15.00 wydanie 4 z dnia 14.07.2020 r. | na podstawie testu HACH LANGE LCK 327 Woda do spozycia przez ludzi Twardosc ogolna\nZakres:\nZakres (1,00 – 55,8) O dH\nZakres (17,9 – 1000) mg/l CaCO3\nMetoda spektrofotometryczna PB-15.00 wydanie 4 z dnia 14.07.2020 r. | na podstawie testu HACH LANGE LCK 327","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total hardness","parameters_en":[{"name":"Range","range":"(1,00 – 55,8) O dH"},{"name":"Range","range":"(17,9 – 1000) mg/l CaCO3"}],"search_en":"Water intended for human consumption Total hardness Spectrophotometric method Range Range PB-15.00 wydanie 4 z dnia 14.07.2020 r. | na podstawie testu HACH LANGE LCK 327","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(1,00 – 55,8) O dH"},{"name":"范围","range":"(17,9 – 1000) mg/l CaCO3"}],"search_zh":"生活饮用水 总硬度 分光光度法 范围 范围 PB-15.00 wydanie 4 z dnia 14.07.2020 r. | na podstawie testu HACH LANGE LCK 327","technique_zh":"分光光度法","test_object_zh":"生活饮用水","methodology_zh":"总硬度"},{"_id":"6a7f0bd71995264369d8e2e5","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,20 – 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,20 – 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Mętność\nZakres (0,20 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda do spozycia przez ludzi Metnosc\nZakres (0,20 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,20 – 100) NTU"}],"search_en":"Water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 – 100) NTU"}],"search_zh":"生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"生活饮用水"},{"_id":"6a7f0bd71995264369d8e2e6","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(3,0 – 45,0) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (3,0 – 45,0) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 metoda C","norm_bases":["PN-EN ISO 7887:2012 metoda C"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Barwa\nZakres (3,0 – 45,0) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C Woda do spozycia przez ludzi Barwa\nZakres (3,0 – 45,0) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(3,0 – 45,0) mg/l Pt"}],"search_en":"Water intended for human consumption Colour Spectrophotometric method Range PN-EN ISO 7887:2012 metoda C","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(3,0 – 45,0) mg/l Pt"}],"search_zh":"生活饮用水 色度 分光光度法 范围 PN-EN ISO 7887:2012 metoda C","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a7f0bd71995264369d8e2e7","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(10 – 2000) µg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (10 – 2000) µg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001 pkt. 7.2","norm_bases":["PN-ISO 6332:2001 pkt. 7.2"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie żelaza\nZakres (10 – 2000) µg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 pkt. 7.2 Woda do spozycia przez ludzi Stezenie zelaza\nZakres (10 – 2000) µg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 pkt. 7.2","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(10 – 2000) µg/l"}],"search_en":"Water intended for human consumption Iron concentration Spectrophotometric method Range PN-ISO 6332:2001 pkt. 7.2","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(10 – 2000) µg/l"}],"search_zh":"生活饮用水 铁浓度 分光光度法 范围 PN-ISO 6332:2001 pkt. 7.2","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a7f0bd71995264369d8e2e8","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,50 – 10,0) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,50 – 10,0) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Indeks nadmanganianowy\nZakres (0,50 – 10,0) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda do spozycia przez ludzi Indeks nadmanganianowy\nZakres (0,50 – 10,0) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,50 – 10,0) mg/l O2"}],"search_en":"Water intended for human consumption Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,50 – 10,0) mg/l O2"}],"search_zh":"生活饮用水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"生活饮用水"},{"_id":"6a7f0bd71995264369d8e2e9","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6"],"lab_section":"Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6","categories":["water","microbiology"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6","test_object_en":"Water intended for human consumption","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6","test_object_zh":"生活饮用水"},{"_id":"6a7f0bd71995264369d8e2ea","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"NPL bakterii z grupy coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"NPL bakterii z grupy coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi NPL bakterii z grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda do spozycia przez ludzi NPL bakterii z grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water intended for human consumption MPN method PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"生活饮用水"},{"_id":"6a7f0bd71995264369d8e2eb","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"NPL bakterii Escherichia coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"NPL bakterii Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi NPL bakterii Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda do spozycia przez ludzi NPL bakterii Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["microbiology","water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water intended for human consumption MPN method PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"生活饮用水"},{"_id":"6a7f0bd71995264369d8e2ec","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"NPL bakterii Enterokoki","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"NPL bakterii Enterokoki\nMetoda NPL","reference":"PB-27.00 wydanie 3 z dnia 03.04.2025 r.","norm_bases":["PB-27.00 wydanie 3 z dnia 03.04.2025 r."],"lab_section":"Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi NPL bakterii Enterokoki\nMetoda NPL PB-27.00 wydanie 3 z dnia 03.04.2025 r. Woda do spozycia przez ludzi NPL bakterii Enterokoki\nMetoda NPL PB-27.00 wydanie 3 z dnia 03.04.2025 r.","categories":["water","microbiology"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water intended for human consumption MPN method PB-27.00 wydanie 3 z dnia 03.04.2025 r.","technique_en":"MPN method","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 最可能数法（MPN） PB-27.00 wydanie 3 z dnia 03.04.2025 r.","technique_zh":"最可能数法（MPN）","test_object_zh":"生活饮用水"},{"_id":"6a7f0bd71995264369d8e2ed","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólnej liczby mikroorganizmów w 36 ⁰C","parameters":[],"technique":"Metoda płytkowa posiewu wgłębnego","techniques":["Metoda płytkowa posiewu wgłębnego"],"computed":[],"activity":"Ogólnej liczby mikroorganizmów w 36 ⁰C\nMetoda płytkowa posiewu wgłębnego","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólnej liczby mikroorganizmów w 36 ⁰C\nMetoda płytkowa posiewu wgłębnego PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolnej liczby mikroorganizmow w 36 ⁰C\nMetoda plytkowa posiewu wglebnego PN-EN ISO 6222:2004","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water intended for human consumption PN-EN ISO 6222:2004","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 PN-EN ISO 6222:2004","test_object_zh":"生活饮用水"},{"_id":"6a7f0bd71995264369d8e2ee","lab_id":"69ad52a3de79e566650fb566","country":"PL","accr_number":"AB 1063","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólnej liczby mikroorganizmów w 22 ⁰C","parameters":[],"technique":"Metoda płytkowa posiewu wgłębnego","techniques":["Metoda płytkowa posiewu wgłębnego"],"computed":[],"activity":"Ogólnej liczby mikroorganizmów w 22 ⁰C\nMetoda płytkowa posiewu wgłębnego","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólnej liczby mikroorganizmów w 22 ⁰C\nMetoda płytkowa posiewu wgłębnego PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolnej liczby mikroorganizmow w 22 ⁰C\nMetoda plytkowa posiewu wglebnego PN-EN ISO 6222:2004","categories":["water"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water intended for human consumption PN-EN ISO 6222:2004","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 PN-EN ISO 6222:2004","test_object_zh":"生活饮用水"}],"has_pdf":true}