{"lab":{"_id":"69ad52a3de79e566650fb564","accr_number":"AB 1060","country":"PL","accr_body":"PCA","address":"LABORATORIUM DZIAŁU OCHRONY ŚRODOWISKA, ul. Ks. Józefa Schulza 5, 85-315 Bydgoszcz","categories":["petro","environment"],"city":"Bydgoszcz","imported_at":"2026-03-08T10:42:43.265Z","methods_count":20,"name":"KOMUNALNE PRZEDSIĘBIORSTWO ENERGETYKI CIEPLNEJ Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1060.pdf"],"scope_summary":"","search_text":"komunalne przedsiębiorstwo energetyki cieplnej sp. z o.o. laboratorium działu ochrony środowiska, ul. ks. józefa schulza 5, 85-315 bydgoszcz petro other","status":"active","updated_at":"2026-03-08T14:50:14.582Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:14.582Z","parse_date":"2026-07-17T16:18:50.825Z","parse_source":"m5-mistral-qa","email_confidence":"high","email_mx":true,"email_source":"https://www.kpec.bydgoszcz.pl/strona/kontakt","fields_of_testing":[{"codes":"C/10; C/36","pl":"Badania chemiczne paliw stałych, gazów odlotowych","en":"Chemical tests of solid fuels, waste gases"},{"codes":"G/36","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – gazy odlotowe","en":"Tests concerning environmental engineering (environmental and climatic) – waste gases"},{"codes":"N/10; N/36","pl":"Badania właściwości fizycznych paliw stałych, gazów odlotowych","en":"Tests of physical properties of solid fuels, waste gases"},{"codes":"P/36","pl":"Pobieranie próbek gazów odlotowych","en":"Sampling of waste gases"}],"issue":{"no":"17","date":"16.06.2025"},"map_coord":[53.115578,17.957911],"map_geo":"nominatim-street","has_en":true,"category_counts":{"other":8,"petro":8,"environment":4},"category_scores":{"other":3.2,"petro":3.2,"environment":0.8},"has_zh":true},"methods":[{"_id":"6a5a55ea9af9f73f3824fc07","lab_id":"69ad52a3de79e566650fb564","country":"PL","accr_number":"AB 1060","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci przemijającej Zakres: (0,5 – 25,0) % Metoda wagowa","methodology_en":"Transient moisture content Range: (0,5 – 25,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci przemijającej Zakres: (0,5 – 25,0) % Metoda wagowa","reference":"PN-G-04611:2020-06","norm_bases":["PN-G-04611:2020-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci przemijającej Zakres: (0,5 – 25,0) % Metoda wagowa PN-G-04611:2020-06 Paliwa stale: wegiel kamienny Zawartosc wilgoci przemijajacej Zakres: (0,5 – 25,0) % Metoda wagowa PN-G-04611:2020-06","categories":["petro"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Transient moisture content Range: (0,5 – 25,0) % Gravimetric method PN-G-04611:2020-06","search_zh":"固体燃料：烟煤 PN-G-04611:2020-06","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ea9af9f73f3824fc08","lab_id":"69ad52a3de79e566650fb564","country":"PL","accr_number":"AB 1060","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci w próbce analitycznej Zakres: (0,5 – 18,0) % Metoda wagowa","methodology_en":"Moisture content in the analytical sample Range: (0,5 – 18,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej Zakres: (0,5 – 18,0) % Metoda wagowa","reference":"PN-G-04611:2020-06","norm_bases":["PN-G-04611:2020-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej Zakres: (0,5 – 18,0) % Metoda wagowa PN-G-04611:2020-06 Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej Zakres: (0,5 – 18,0) % Metoda wagowa PN-G-04611:2020-06","categories":["petro"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Moisture content in the analytical sample Range: (0,5 – 18,0) % Gravimetric method PN-G-04611:2020-06","search_zh":"固体燃料：烟煤 PN-G-04611:2020-06","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ea9af9f73f3824fc09","lab_id":"69ad52a3de79e566650fb564","country":"PL","accr_number":"AB 1060","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci całkowitej (z obliczeń)","methodology_en":"Total moisture content (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej (z obliczeń)","reference":"PN-G-04611:2020-06","norm_bases":["PN-G-04611:2020-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej (z obliczeń) PN-G-04611:2020-06 Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej (z obliczen) PN-G-04611:2020-06","categories":["petro"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Total moisture content (calculated) PN-G-04611:2020-06","search_zh":"固体燃料：烟煤 全水分含量（计算值） PN-G-04611:2020-06","test_object_zh":"固体燃料：烟煤","methodology_zh":"全水分含量（计算值）"},{"_id":"6a5a55ea9af9f73f3824fc0a","lab_id":"69ad52a3de79e566650fb564","country":"PL","accr_number":"AB 1060","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość popiołu Zakres: (0,7 – 50,0) % Metoda wagowa","methodology_en":"Ash content Range: (0,7 – 50,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość popiołu Zakres: (0,7 – 50,0) % Metoda wagowa","reference":"PN-ISO 1171:2002","norm_bases":["PN-ISO 1171:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu Zakres: (0,7 – 50,0) % Metoda wagowa PN-ISO 1171:2002 Paliwa stale: wegiel kamienny Zawartosc popiolu Zakres: (0,7 – 50,0) % Metoda wagowa PN-ISO 1171:2002","categories":["petro"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Ash content Range: (0,7 – 50,0) % Gravimetric method PN-ISO 1171:2002","search_zh":"固体燃料：烟煤 PN-ISO 1171:2002","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ea9af9f73f3824fc0b","lab_id":"69ad52a3de79e566650fb564","country":"PL","accr_number":"AB 1060","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Ciepło spalania Zakres: (12 000 – 35 000) kJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń)","methodology_en":"Gross calorific value Range: (12 000 – 35 000) kJ/kg Calorimetric method Net calorific value (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciepło spalania Zakres: (12 000 – 35 000) kJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń)","reference":"PN-81/G-04513","norm_bases":["PN-81/G-04513"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Ciepło spalania Zakres: (12 000 – 35 000) kJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń) PN-81/G-04513 Paliwa stale: wegiel kamienny Cieplo spalania Zakres: (12 000 – 35 000) kJ/kg Metoda kalorymetryczna Wartosc opalowa (z obliczen) PN-81/G-04513","categories":["petro"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Gross calorific value Range: (12 000 – 35 000) kJ/kg Calorimetric method Net calorific value (calculated) PN-81/G-04513","search_zh":"固体燃料：烟煤 PN-81/G-04513","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ea9af9f73f3824fc0c","lab_id":"69ad52a3de79e566650fb564","country":"PL","accr_number":"AB 1060","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość siarki całkowitej Zakres: (0,100 – 2,500) % Metoda wagowa","methodology_en":"Total sulphur content Range: (0,100 – 2,500) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej Zakres: (0,100 – 2,500) % Metoda wagowa","reference":"PN-ISO 334:1997","norm_bases":["PN-ISO 334:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość siarki całkowitej Zakres: (0,100 – 2,500) % Metoda wagowa PN-ISO 334:1997 Paliwa stale: wegiel kamienny Zawartosc siarki calkowitej Zakres: (0,100 – 2,500) % Metoda wagowa PN-ISO 334:1997","categories":["petro"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Total sulphur content Range: (0,100 – 2,500) % Gravimetric method PN-ISO 334:1997","search_zh":"固体燃料：烟煤 PN-ISO 334:1997","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ea9af9f73f3824fc0d","lab_id":"69ad52a3de79e566650fb564","country":"PL","accr_number":"AB 1060","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość siarki całkowitej Zakres: (0,10 – 2,50) % Metoda wysokotemperaturowego spalania z detekcją IR","methodology_en":"Total sulfur content Range: (0,10 – 2,50) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej Zakres: (0,10 – 2,50) % Metoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001","norm_bases":["PN-G-04584:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość siarki całkowitej Zakres: (0,10 – 2,50) % Metoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 Paliwa stale: wegiel kamienny Zawartosc siarki calkowitej Zakres: (0,10 – 2,50) % Metoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001","categories":["petro"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Total sulfur content Range: (0,10 – 2,50) % High-temperature combustion method with IR detection PN-G-04584:2001","search_zh":"固体燃料：烟煤 PN-G-04584:2001","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ea9af9f73f3824fc0e","lab_id":"69ad52a3de79e566650fb564","country":"PL","accr_number":"AB 1060","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość węgla całkowitego Zakres: (12,0 – 85,0) % Metoda wysokotemperaturowego spalania z detekcją IR","methodology_en":"Total carbon content Range: (12,0 – 85,0) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego Zakres: (12,0 – 85,0) % Metoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość węgla całkowitego Zakres: (12,0 – 85,0) % Metoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc wegla calkowitego Zakres: (12,0 – 85,0) % Metoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Total carbon content Range: (12,0 – 85,0) % High-temperature combustion method with IR detection PN-G-04571:1998","search_zh":"固体燃料：烟煤 PN-G-04571:1998","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ea9af9f73f3824fc0f","lab_id":"69ad52a3de79e566650fb564","country":"PL","accr_number":"AB 1060","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa Metoda spiętrzenia","methodology_en":"Gas volume flow rate for dynamic pressures > 10 Pa Pitot tube method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa Metoda spiętrzenia","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa Metoda spiętrzenia PN-Z-04030-7:1994 Gazy odlotowe Strumien objetosci gazu dla cisnien dynamicznych > 10 Pa Metoda spietrzenia PN-Z-04030-7:1994","categories":["other"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Gas volume flow rate for dynamic pressures > 10 Pa Pitot tube method PN-Z-04030-7:1994","search_zh":"废气 动压 > 10 Pa 时的气体体积流量 皮托管法 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"动压 > 10 Pa 时的气体体积流量 皮托管法"},{"_id":"6a5a55ea9af9f73f3824fc10","lab_id":"69ad52a3de79e566650fb564","country":"PL","accr_number":"AB 1060","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Metoda spiętrzenia","methodology_en":"Stagnation pressure method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Metoda spiętrzenia","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Metoda spiętrzenia Gazy odlotowe Metoda spietrzenia","categories":["other"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Stagnation pressure method","search_zh":"废气 滞止压力法","test_object_zh":"废气","methodology_zh":"滞止压力法"},{"_id":"6a5a55ea9af9f73f3824fc11","lab_id":"69ad52a3de79e566650fb564","country":"PL","accr_number":"AB 1060","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","methodology_en":"Sampling for determination of dust concentration","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu","categories":["other"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of dust concentration","search_zh":"废气 粉尘浓度测定采样","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样"},{"_id":"6a5a55ea9af9f73f3824fc12","lab_id":"69ad52a3de79e566650fb564","country":"PL","accr_number":"AB 1060","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pyłu Zakres: (0,001 – 30) g/m3 Metoda grawimetryczna","methodology_en":"Dust concentration Range: (0,001 – 30) g/m3 Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pyłu Zakres: (0,001 – 30) g/m3 Metoda grawimetryczna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pyłu Zakres: (0,001 – 30) g/m3 Metoda grawimetryczna Gazy odlotowe Stezenie pylu Zakres: (0,001 – 30) g/m3 Metoda grawimetryczna","categories":["other"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Dust concentration Range: (0,001 – 30) g/m3 Gravimetric method","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a55ea9af9f73f3824fc13","lab_id":"69ad52a3de79e566650fb564","country":"PL","accr_number":"AB 1060","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja pyłu (z obliczeń)","methodology_en":"Dust emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja pyłu (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) Gazy odlotowe Emisja pylu (z obliczen)","categories":["environment"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Dust emission (calculated)","search_zh":"废气 粉尘排放量（计算值）","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a5a55ea9af9f73f3824fc14","lab_id":"69ad52a3de79e566650fb564","country":"PL","accr_number":"AB 1060","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie dwutlenku siarki Zakres: (40 – 1600) mg/m3 Metoda niedyspersyjnej spektrometrii w poczerwieni (NDIR)","methodology_en":"Sulphur dioxide concentration Range: (40 – 1600) mg/m3 Non-dispersive infrared spectrometry method (NDIR)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie dwutlenku siarki Zakres: (40 – 1600) mg/m3 Metoda niedyspersyjnej spektrometrii w poczerwieni (NDIR)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie dwutlenku siarki Zakres: (40 – 1600) mg/m3 Metoda niedyspersyjnej spektrometrii w poczerwieni (NDIR) PN-ISO 10396:2001 Gazy odlotowe Stezenie dwutlenku siarki Zakres: (40 – 1600) mg/m3 Metoda niedyspersyjnej spektrometrii w poczerwieni (NDIR) PN-ISO 10396:2001","categories":["other"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sulphur dioxide concentration Range: (40 – 1600) mg/m3 Non-dispersive infrared spectrometry method (NDIR) PN-ISO 10396:2001","search_zh":"废气 PN-ISO 10396:2001","test_object_zh":"废气"},{"_id":"6a5a55ea9af9f73f3824fc15","lab_id":"69ad52a3de79e566650fb564","country":"PL","accr_number":"AB 1060","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja SO 2 (z obliczeń)","methodology_en":"SO 2 emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja SO 2 (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja SO 2 (z obliczeń) Gazy odlotowe Emisja SO 2 (z obliczen)","categories":["environment"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases SO 2 emission (calculated)","search_zh":"废气 SO2 排放（由计算得出）","test_object_zh":"废气","methodology_zh":"SO2 排放（由计算得出）"},{"_id":"6a5a55ea9af9f73f3824fc16","lab_id":"69ad52a3de79e566650fb564","country":"PL","accr_number":"AB 1060","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenu Zakres: (2,0 – 16,0) % Metoda paramagnetyczna","methodology_en":"Oxygen concentration Range: (2,0 – 16,0) % Paramagnetic method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenu Zakres: (2,0 – 16,0) % Metoda paramagnetyczna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenu Zakres: (2,0 – 16,0) % Metoda paramagnetyczna Gazy odlotowe Stezenie tlenu Zakres: (2,0 – 16,0) % Metoda paramagnetyczna","categories":["other"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Oxygen concentration Range: (2,0 – 16,0) % Paramagnetic method","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a55ea9af9f73f3824fc17","lab_id":"69ad52a3de79e566650fb564","country":"PL","accr_number":"AB 1060","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenku azotu, tlenków azotu Zakres: NO (20 – 500) mg/m3 NO (30 – 800) mg/m3 x Metoda chemiluminescencyjna","methodology_en":"Concentration of nitrogen monoxide, nitrogen oxides Range: NO (20 – 500) mg/m3 NO (30 – 800) mg/m3 x Chemiluminescence method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenku azotu, tlenków azotu Zakres: NO (20 – 500) mg/m3 NO (30 – 800) mg/m3 x Metoda chemiluminescencyjna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenku azotu, tlenków azotu Zakres: NO (20 – 500) mg/m3 NO (30 – 800) mg/m3 x Metoda chemiluminescencyjna Gazy odlotowe Stezenie tlenku azotu, tlenkow azotu Zakres: NO (20 – 500) mg/m3 NO (30 – 800) mg/m3 x Metoda chemiluminescencyjna","categories":["other"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Concentration of nitrogen monoxide, nitrogen oxides Range: NO (20 – 500) mg/m3 NO (30 – 800) mg/m3 x Chemiluminescence method","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a55ea9af9f73f3824fc18","lab_id":"69ad52a3de79e566650fb564","country":"PL","accr_number":"AB 1060","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja NO, NO (NO i NO w x 2 przeliczeniu na NO ) 2 (z obliczeń)","methodology_en":"Emission of NO, NO (NO and NO in x 2 calculated as NO ) 2 (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja NO, NO (NO i NO w x 2 przeliczeniu na NO ) 2 (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja NO, NO (NO i NO w x 2 przeliczeniu na NO ) 2 (z obliczeń) Gazy odlotowe Emisja NO, NO (NO i NO w x 2 przeliczeniu na NO ) 2 (z obliczen)","categories":["environment"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of NO, NO (NO and NO in x 2 calculated as NO ) 2 (calculated)","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a55ea9af9f73f3824fc19","lab_id":"69ad52a3de79e566650fb564","country":"PL","accr_number":"AB 1060","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie dwutlenku węgla Zakres: (1,0 – 18) % Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","methodology_en":"Carbon dioxide concentration Range: (1,0 – 18) % Non-dispersive infrared spectrometry method (NDIR)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie dwutlenku węgla Zakres: (1,0 – 18) % Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie dwutlenku węgla Zakres: (1,0 – 18) % Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) Gazy odlotowe Stezenie dwutlenku wegla Zakres: (1,0 – 18) % Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","categories":["other"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Carbon dioxide concentration Range: (1,0 – 18) % Non-dispersive infrared spectrometry method (NDIR)","search_zh":"废气 二氧化碳浓度 范围：(1,0 – 18) % 非分散红外光谱法（NDIR）","test_object_zh":"废气","methodology_zh":"二氧化碳浓度 范围：(1,0 – 18) % 非分散红外光谱法（NDIR）"},{"_id":"6a5a55ea9af9f73f3824fc1a","lab_id":"69ad52a3de79e566650fb564","country":"PL","accr_number":"AB 1060","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja CO 2 (z obliczeń)","methodology_en":"CO 2 emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja CO 2 (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja CO 2 (z obliczeń) Gazy odlotowe Emisja CO 2 (z obliczen)","categories":["environment"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases CO 2 emission (calculated)","search_zh":"废气","test_object_zh":"废气"}],"has_pdf":true}