{"lab":{"_id":"69ad52a3de79e566650fb560","accr_number":"AB 1057","country":"PL","accr_body":"PCA","address":"ATMOSFERY GDAŃSK-GDYNIA-SOPOT”, ul. Brzozowa 15A, 80-243 Gdańsk","categories":["environment"],"city":"Gdańsk","imported_at":"2026-03-08T10:42:43.265Z","methods_count":7,"name":"FUNDACJA „AGENCJA REGIONALNEGO MONITORINGU","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1057.pdf"],"scope_summary":"","search_text":"fundacja „agencja regionalnego monitoringu atmosfery gdańsk-gdynia-sopot”, ul. brzozowa 15a, 80-243 gdańsk environment other metrology","status":"active","updated_at":"2026-03-08T14:50:14.338Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:14.338Z","parse_date":"2026-07-17T16:18:50.652Z","parse_source":"m5-mistral-qa","email_confidence":"high","email_mx":true,"email_source":"https://armaag.gda.pl/kontakt.htm","fields_of_testing":[{"codes":"C/9/P","pl":"Badania chemiczne i pobieranie próbek powietrza","en":"Chemical tests and sampling of air"}],"issue":{"no":"17","date":"06.06.2025"},"map_coord":[54.379382,18.606602],"map_geo":"nominatim-street","has_en":true,"category_counts":{"environment":7},"category_scores":{"environment":7},"has_zh":true},"methods":[{"_id":"6a5a55ea9af9f73f3824fb98","lab_id":"69ad52a3de79e566650fb560","country":"PL","accr_number":"AB 1057","accr_body":"PCA","test_object":"Środowisko ogólne − powietrze atmosferyczne","test_object_en":"General environment − ambient air","methodology":"Stężenie ditlenku siarki Zakres: (2,7 − 1000) µg/m³ Metoda fluoroscencyjna w nadfiolecie","methodology_en":"Sulphur dioxide concentration Range: (2,7 − 1000) µg/m³ Ultraviolet fluorescence method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie ditlenku siarki Zakres: (2,7 − 1000) µg/m³ Metoda fluoroscencyjna w nadfiolecie","reference":"PN-EN 14212:2013-02","norm_bases":["PN-EN 14212:2013-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne − powietrze atmosferyczne Stężenie ditlenku siarki Zakres: (2,7 − 1000) µg/m³ Metoda fluoroscencyjna w nadfiolecie PN-EN 14212:2013-02 Srodowisko ogolne − powietrze atmosferyczne Stezenie ditlenku siarki Zakres: (2,7 − 1000) µg/m³ Metoda fluoroscencyjna w nadfiolecie PN-EN 14212:2013-02","categories":["environment"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment − ambient air Sulphur dioxide concentration Range: (2,7 − 1000) µg/m³ Ultraviolet fluorescence method PN-EN 14212:2013-02","search_zh":"一般环境 － 大气空气 PN-EN 14212:2013-02","test_object_zh":"一般环境 － 大气空气"},{"_id":"6a5a55ea9af9f73f3824fb99","lab_id":"69ad52a3de79e566650fb560","country":"PL","accr_number":"AB 1057","accr_body":"PCA","test_object":"Środowisko ogólne − powietrze atmosferyczne","test_object_en":"General environment − ambient air","methodology":"Stężenie tlenku azotu Zakres: (1,3 − 625) µg/m³ Metoda chemiluminescencyjna","methodology_en":"Nitrogen monoxide concentration Range: (1,3 − 625) µg/m³ Chemiluminescence method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenku azotu Zakres: (1,3 − 625) µg/m³ Metoda chemiluminescencyjna","reference":"PN-EN 14211:2013-02","norm_bases":["PN-EN 14211:2013-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne − powietrze atmosferyczne Stężenie tlenku azotu Zakres: (1,3 − 625) µg/m³ Metoda chemiluminescencyjna PN-EN 14211:2013-02 Srodowisko ogolne − powietrze atmosferyczne Stezenie tlenku azotu Zakres: (1,3 − 625) µg/m³ Metoda chemiluminescencyjna PN-EN 14211:2013-02","categories":["environment"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment − ambient air Nitrogen monoxide concentration Range: (1,3 − 625) µg/m³ Chemiluminescence method PN-EN 14211:2013-02","search_zh":"一般环境 － 大气空气 PN-EN 14211:2013-02","test_object_zh":"一般环境 － 大气空气"},{"_id":"6a5a55ea9af9f73f3824fb9a","lab_id":"69ad52a3de79e566650fb560","country":"PL","accr_number":"AB 1057","accr_body":"PCA","test_object":"Środowisko ogólne − powietrze atmosferyczne","test_object_en":"General environment − ambient air","methodology":"Stężenie ditlenku azotu Zakres: (1,9 − 500) µg/m³ Metoda chemiluminescencyjna","methodology_en":"Nitrogen dioxide concentration Range: (1,9 − 500) µg/m³ Chemiluminescence method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie ditlenku azotu Zakres: (1,9 − 500) µg/m³ Metoda chemiluminescencyjna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne − powietrze atmosferyczne Stężenie ditlenku azotu Zakres: (1,9 − 500) µg/m³ Metoda chemiluminescencyjna Srodowisko ogolne − powietrze atmosferyczne Stezenie ditlenku azotu Zakres: (1,9 − 500) µg/m³ Metoda chemiluminescencyjna","categories":["environment"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment − ambient air Nitrogen dioxide concentration Range: (1,9 − 500) µg/m³ Chemiluminescence method","search_zh":"一般环境 － 大气空气","test_object_zh":"一般环境 － 大气空气"},{"_id":"6a5a55ea9af9f73f3824fb9b","lab_id":"69ad52a3de79e566650fb560","country":"PL","accr_number":"AB 1057","accr_body":"PCA","test_object":"Środowisko ogólne − powietrze atmosferyczne","test_object_en":"General environment − ambient air","methodology":"Stężenie tlenków azotu Zakres: (1,9 − 955) µg/m³ Metoda chemiluminescencyjna","methodology_en":"Nitrogen oxides concentration Range: (1,9 − 955) µg/m³ Chemiluminescence method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenków azotu Zakres: (1,9 − 955) µg/m³ Metoda chemiluminescencyjna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne − powietrze atmosferyczne Stężenie tlenków azotu Zakres: (1,9 − 955) µg/m³ Metoda chemiluminescencyjna Srodowisko ogolne − powietrze atmosferyczne Stezenie tlenkow azotu Zakres: (1,9 − 955) µg/m³ Metoda chemiluminescencyjna","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment − ambient air Nitrogen oxides concentration Range: (1,9 − 955) µg/m³ Chemiluminescence method","search_zh":"一般环境 － 大气空气","test_object_zh":"一般环境 － 大气空气"},{"_id":"6a5a55ea9af9f73f3824fb9c","lab_id":"69ad52a3de79e566650fb560","country":"PL","accr_number":"AB 1057","accr_body":"PCA","test_object":"Środowisko ogólne − powietrze atmosferyczne","test_object_en":"General environment − ambient air","methodology":"Stężenie tlenku węgla Zakres: (0,050 − 5,8) mg/m³ Metoda niedyspersyjnej spektroskopii w podczerwieni","methodology_en":"Carbon monoxide concentration Range: (0,050 − 5,8) mg/m³ Non-dispersive infrared spectroscopy method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenku węgla Zakres: (0,050 − 5,8) mg/m³ Metoda niedyspersyjnej spektroskopii w podczerwieni","reference":"PN-EN 14626:2013-02","norm_bases":["PN-EN 14626:2013-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne − powietrze atmosferyczne Stężenie tlenku węgla Zakres: (0,050 − 5,8) mg/m³ Metoda niedyspersyjnej spektroskopii w podczerwieni PN-EN 14626:2013-02 Srodowisko ogolne − powietrze atmosferyczne Stezenie tlenku wegla Zakres: (0,050 − 5,8) mg/m³ Metoda niedyspersyjnej spektroskopii w podczerwieni PN-EN 14626:2013-02","categories":["environment"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment − ambient air Carbon monoxide concentration Range: (0,050 − 5,8) mg/m³ Non-dispersive infrared spectroscopy method PN-EN 14626:2013-02","search_zh":"一般环境 － 大气空气 PN-EN 14626:2013-02","test_object_zh":"一般环境 － 大气空气"},{"_id":"6a5a55ea9af9f73f3824fb9d","lab_id":"69ad52a3de79e566650fb560","country":"PL","accr_number":"AB 1057","accr_body":"PCA","test_object":"Środowisko ogólne − powietrze atmosferyczne","test_object_en":"General environment − ambient air","methodology":"Stężenie ditlenku azotu Zakres: (1,9 – 500) µg/m³ Metoda chemiluminescencyjna","methodology_en":"Nitrogen dioxide concentration Range: (1,9 – 500) µg/m³ Chemiluminescence method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie ditlenku azotu Zakres: (1,9 – 500) µg/m³ Metoda chemiluminescencyjna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne − powietrze atmosferyczne Stężenie ditlenku azotu Zakres: (1,9 – 500) µg/m³ Metoda chemiluminescencyjna Srodowisko ogolne − powietrze atmosferyczne Stezenie ditlenku azotu Zakres: (1,9 – 500) µg/m³ Metoda chemiluminescencyjna","categories":["environment"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment − ambient air Nitrogen dioxide concentration Range: (1,9 – 500) µg/m³ Chemiluminescence method","search_zh":"一般环境 － 大气空气","test_object_zh":"一般环境 － 大气空气"},{"_id":"6a5a55ea9af9f73f3824fb9e","lab_id":"69ad52a3de79e566650fb560","country":"PL","accr_number":"AB 1057","accr_body":"PCA","test_object":"Środowisko ogólne − powietrze atmosferyczne","test_object_en":"General environment − ambient air","methodology":"Stężenie ozonu Zakres: (2,0 − 500) µg/m³ Metoda fotometrii w nadfiolecie","methodology_en":"Ozone concentration Range: (2,0 − 500) µg/m³ Ultraviolet photometry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie ozonu Zakres: (2,0 − 500) µg/m³ Metoda fotometrii w nadfiolecie","reference":"PN-EN 14625:2013-02","norm_bases":["PN-EN 14625:2013-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne − powietrze atmosferyczne Stężenie ozonu Zakres: (2,0 − 500) µg/m³ Metoda fotometrii w nadfiolecie PN-EN 14625:2013-02 Srodowisko ogolne − powietrze atmosferyczne Stezenie ozonu Zakres: (2,0 − 500) µg/m³ Metoda fotometrii w nadfiolecie PN-EN 14625:2013-02","categories":["environment"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment − ambient air Ozone concentration Range: (2,0 − 500) µg/m³ Ultraviolet photometry method PN-EN 14625:2013-02","search_zh":"一般环境 － 大气空气 PN-EN 14625:2013-02","test_object_zh":"一般环境 － 大气空气"}],"has_pdf":true}