{"lab":{"_id":"69ad52a3de79e566650fb552","accr_number":"AB 1047","country":"PL","accr_body":"PCA","address":"ul. Świecka 68, 89-500 Tuchola, LABORATORIUM ANALITYCZNE, ul. Świecka 96 A","categories":["water","microbiology"],"city":"Tuchola","imported_at":"2026-03-08T10:42:43.265Z","methods_count":55,"name":"PRZEDSIĘBIORSTWO KOMUNALNE W TUCHOLI Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1047.pdf"],"scope_summary":"","search_text":"przedsiębiorstwo komunalne w tucholi sp. z o.o. ul. świecka 68, 89-500 tuchola, laboratorium analityczne, ul. świecka 96 a water other pharma electronics microbiology automotive","status":"active","updated_at":"2026-03-08T14:50:13.822Z","valid_from":"","valid_until":"07.06.2029","website":"","parsed_at":"2026-08-14T12:18:43.855Z","parse_date":"2026-08-14T12:18:43.855Z","parse_source":"agent-claude-code","email_confidence":"high","email_mx":true,"email_source":"https://www.pk.tuchola.pl/laboratorium/","fields_of_testing":[{"codes":"C/29/P, C/30/P","pl":"Badania chemiczne i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of drinking water, sewage"},{"codes":"C/28","pl":"Badania chemiczne wody","en":"Chemical tests of water"},{"codes":"K/28/P, K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Microbiological tests and sampling of water, drinking water"},{"codes":"N/29/P, N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of drinking water, sewage"},{"codes":"N/28","pl":"Badania właściwości fizycznych wody","en":"Tests of physical properties of water"}],"issue":{"no":"17","date":"03.06.2026"},"map_coord":[53.582435,17.867647],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM ANALITYCZNE","address":"ul. Świecka 96 A","city":"Tuchola","postal":"89-500"},{"name":"Pracownia Badań Fizyko-Chemicznych","address":"ul. Świecka 96 A, 89-500 Tuchola","city":"Tuchola","postal":"89-500"},{"name":"Pracownia Badań Mikrobiologicznych","address":"ul. Świecka 96 A, 89-500 Tuchola","city":"Tuchola","postal":"89-500"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/14/767e59c9768456b1ac0e67e0e05fc542/AB%201047.pdf","has_en":true,"category_counts":{"water":55,"microbiology":8},"category_scores":{"water":48.02,"microbiology":1.02},"has_zh":true},"methods":[{"_id":"6a7f07a31995264369d8e0d8","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a7f07a31995264369d8e0d9","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Temperatura pobranej próbki wody","parameters":[{"name":"Zakres","range":"(2,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura pobranej próbki wody\nZakres (2,0 – 50,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Temperatura pobranej próbki wody\nZakres (2,0 – 50,0) °C PN-77/C-04584 Woda do spozycia przez ludzi Temperatura pobranej probki wody\nZakres (2,0 – 50,0) °C PN-77/C-04584","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature of the collected water sample","parameters_en":[{"name":"Range","range":"(2,0 – 50,0) °C"}],"search_en":"Water intended for human consumption Temperature of the collected water sample Range PN-77/C-04584","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(2,0 – 50,0) °C"}],"search_zh":"生活饮用水 所采水样的温度 范围 PN-77/C-04584","test_object_zh":"生活饮用水","methodology_zh":"所采水样的温度"},{"_id":"6a7f07a31995264369d8e0da","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,033 – 1,64) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,033 – 1,64) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,033 – 1,64) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,033 – 1,64) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,033 – 1,64) mg/l"}],"search_en":"Water intended for human consumption Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,033 – 1,64) mg/l"}],"search_zh":"生活饮用水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a7f07a31995264369d8e0db","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda na pływalniach, woda do spożycia przez ludzi","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,443 − 443) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,443 − 443) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach, woda do spożycia przez ludzi Stężenie azotanów\nZakres (0,443 − 443) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda na plywalniach, woda do spozycia przez ludzi Stezenie azotanow\nZakres (0,443 − 443) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(0,443 − 443) mg/l"}],"search_en":"Swimming pool water, water intended for human consumption Nitrate concentration Spectrophotometric method Range PN-82/C-04576/08","technique_en":"Spectrophotometric method","test_object_en":"Swimming pool water, water intended for human consumption","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,443 − 443) mg/l"}],"search_zh":"硝酸盐浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法"},{"_id":"6a7f07a31995264369d8e0dc","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(100 − 3000) µS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (100 − 3000) µS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (100 − 3000) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (100 − 3000) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(100 − 3000) µS/cm"}],"search_en":"Water, water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(100 − 3000) µS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f07a31995264369d8e0dd","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,030 − 0,70) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (0,030 − 0,70) mg/l\nMetoda spektrofotometryczna","reference":"PB-02 edycja 04 z dnia 02.01.2020 r. w oparciu o test firmy Hach Lange 8149","norm_bases":["PB-02 edycja 04 z dnia 02.01.2020 r. w oparciu o test firmy Hach Lange 8149"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie manganu\nZakres (0,030 − 0,70) mg/l\nMetoda spektrofotometryczna PB-02 edycja 04 z dnia 02.01.2020 r. w oparciu o test firmy Hach Lange 8149 Woda, woda do spozycia przez ludzi Stezenie manganu\nZakres (0,030 − 0,70) mg/l\nMetoda spektrofotometryczna PB-02 edycja 04 z dnia 02.01.2020 r. w oparciu o test firmy Hach Lange 8149","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(0,030 − 0,70) mg/l"}],"search_en":"Water, water intended for human consumption Manganese concentration Spectrophotometric method Range PB-02 edycja 04 z dnia 02.01.2020 r. w oparciu o test firmy Hach Lange 8149","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,030 − 0,70) mg/l"}],"search_zh":"水、生活饮用水 锰浓度 分光光度法 范围 PB-02 edycja 04 z dnia 02.01.2020 r. w oparciu o test firmy Hach Lange 8149","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f07a31995264369d8e0de","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,050 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,050 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001 pkt 7.1.1 +Ap1:2016-06","norm_bases":["PN-ISO 6332:2001 pkt 7.1.1 +Ap1:2016-06"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie żelaza ogólnego\nZakres (0,050 – 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 pkt 7.1.1 +Ap1:2016-06 Woda, woda do spozycia przez ludzi Stezenie zelaza ogolnego\nZakres (0,050 – 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 pkt 7.1.1 +Ap1:2016-06","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,050 – 10,0) mg/l"}],"search_en":"Water, water intended for human consumption Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001 pkt 7.1.1 +Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 10,0) mg/l"}],"search_zh":"水、生活饮用水 总铁浓度 分光光度法 范围 PN-ISO 6332:2001 pkt 7.1.1 +Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f07a31995264369d8e0df","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Sumaryczna zawartość wapnia i magnezu","parameters":[{"name":"Zakres","range":"(10 − 500) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu\nZakres (10 − 500) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu\nZakres (10 − 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu\nZakres (10 − 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(10 − 500) mg/l CaCO3"}],"search_en":"Water, water intended for human consumption Titrimetric method Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(10 − 500) mg/l CaCO3"}],"search_zh":"水、生活饮用水 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f07a31995264369d8e0e0","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Zawartość fluorków","parameters":[{"name":"Zakres","range":"(0,20 – 2,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fluorków\nZakres (0,20 – 2,00) mg/l\nMetoda spektrofotometryczna","reference":"PB-09 edycja 03 z dnia 02.01.2020 r. w oparciu o test firmy Hach Lange 8029","norm_bases":["PB-09 edycja 03 z dnia 02.01.2020 r. w oparciu o test firmy Hach Lange 8029"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Zawartość fluorków\nZakres (0,20 – 2,00) mg/l\nMetoda spektrofotometryczna PB-09 edycja 03 z dnia 02.01.2020 r. w oparciu o test firmy Hach Lange 8029 Woda, woda do spozycia przez ludzi Zawartosc fluorkow\nZakres (0,20 – 2,00) mg/l\nMetoda spektrofotometryczna PB-09 edycja 03 z dnia 02.01.2020 r. w oparciu o test firmy Hach Lange 8029","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fluoride content","parameters_en":[{"name":"Range","range":"(0,20 – 2,00) mg/l"}],"search_en":"Water, water intended for human consumption Fluoride content Spectrophotometric method Range PB-09 edycja 03 z dnia 02.01.2020 r. w oparciu o test firmy Hach Lange 8029","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,20 – 2,00) mg/l"}],"search_zh":"水、生活饮用水 氟化物含量 分光光度法 范围 PB-09 edycja 03 z dnia 02.01.2020 r. w oparciu o test firmy Hach Lange 8029","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","methodology_zh":"氟化物含量"},{"_id":"6a7f07a31995264369d8e0e1","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 − 70) mg/l Pt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa\nZakres (5 − 70) mg/l Pt\nMetoda wizualna","reference":"PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D","norm_bases":["PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Barwa\nZakres (5 − 70) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D Woda, woda do spozycia przez ludzi Barwa\nZakres (5 − 70) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 − 70) mg/l Pt"}],"search_en":"Water, water intended for human consumption Colour Visual method Range PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D","technique_en":"Visual method","test_object_en":"Water, water intended for human consumption","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 − 70) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 目视法 范围 PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D","technique_zh":"目视法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f07a31995264369d8e0e2","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,030 − 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,030 − 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,030 − 1,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,030 − 1,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,030 − 1,0) mg/l"}],"search_en":"Water, water intended for human consumption Ammonium ion concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,030 − 1,0) mg/l"}],"search_zh":"水、生活饮用水 铵离子浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f07a31995264369d8e0e3","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie wapnia","parameters":[{"name":"Zakres","range":"(10 − 200) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie wapnia\nZakres (10 − 200) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie wapnia\nZakres (10 − 200) mg/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda, woda do spozycia przez ludzi Stezenie wapnia\nZakres (10 − 200) mg/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Calcium concentration","parameters_en":[{"name":"Range","range":"(10 − 200) mg/l"}],"search_en":"Water, water intended for human consumption Calcium concentration Titrimetric method Range PN-ISO 6058:1999","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(10 − 200) mg/l"}],"search_zh":"水、生活饮用水 钙浓度 滴定法 范围 PN-ISO 6058:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","methodology_zh":"钙浓度"},{"_id":"6a7f07a31995264369d8e0e4","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie magnezu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie magnezu (z obliczeń)","reference":"PN-99/C-4554-04 załącznik A","norm_bases":["PN-99/C-4554-04 załącznik A"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie magnezu (z obliczeń) PN-99/C-4554-04 załącznik A Woda, woda do spozycia przez ludzi Stezenie magnezu (z obliczen) PN-99/C-4554-04 zalacznik A","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnesium concentration (calculated)","search_en":"Water, water intended for human consumption Magnesium concentration (calculated) PN-99/C-4554-04 załącznik A","test_object_en":"Water, water intended for human consumption","search_zh":"水、生活饮用水 镁浓度（计算值） PN-99/C-4554-04 załącznik A","test_object_zh":"水、生活饮用水","methodology_zh":"镁浓度（计算值）"},{"_id":"6a7f07a31995264369d8e0e5","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi","methodology":"Stężenie glinu","parameters":[{"name":"Zakres","range":"(0,050 – 1,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie glinu\nZakres (0,050 – 1,00) mg/l\nMetoda spektrofotometryczna","reference":"PB-08 edycja 03 z dnia 02.01.2020 r. w oparciu o test firmy Hach Lange 8326","norm_bases":["PB-08 edycja 03 z dnia 02.01.2020 r. w oparciu o test firmy Hach Lange 8326"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi Stężenie glinu\nZakres (0,050 – 1,00) mg/l\nMetoda spektrofotometryczna PB-08 edycja 03 z dnia 02.01.2020 r. w oparciu o test firmy Hach Lange 8326 Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi Stezenie glinu\nZakres (0,050 – 1,00) mg/l\nMetoda spektrofotometryczna PB-08 edycja 03 z dnia 02.01.2020 r. w oparciu o test firmy Hach Lange 8326","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Aluminium concentration","parameters_en":[{"name":"Range","range":"(0,050 – 1,00) mg/l"}],"search_en":"Water (including swimming pool water), water intended for human consumption Aluminium concentration Spectrophotometric method Range PB-08 edycja 03 z dnia 02.01.2020 r. w oparciu o test firmy Hach Lange 8326","technique_en":"Spectrophotometric method","test_object_en":"Water (including swimming pool water), water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,050 – 1,00) mg/l"}],"search_zh":"水（含游泳池水）、生活饮用水 铝浓度 分光光度法 范围 PB-08 edycja 03 z dnia 02.01.2020 r. w oparciu o test firmy Hach Lange 8326","technique_zh":"分光光度法","methodology_zh":"铝浓度","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a7f07a31995264369d8e0e6","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,20 − 40) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,20 − 40) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi Mętność\nZakres (0,20 − 40) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi Metnosc\nZakres (0,20 − 40) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,20 − 40) NTU"}],"search_en":"Water (including swimming pool water), water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 − 40) NTU"}],"search_zh":"水（含游泳池水）、生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a7f07a31995264369d8e0e7","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,50 – 10,0) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,50 – 10,0) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi Indeks nadmanganianowy\nZakres (0,50 – 10,0) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi Indeks nadmanganianowy\nZakres (0,50 – 10,0) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,50 – 10,0) mg/l O2"}],"search_en":"Water (including swimming pool water), water intended for human consumption Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,50 – 10,0) mg/l O2"}],"search_zh":"水（含游泳池水）、生活饮用水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a7f07a31995264369d8e0e8","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi","methodology":"Potencjał utleniająco-redukujący (redoks) wzgl. Ag/AgCl 3,5 mol KCl","parameters":[{"name":"Zakres","range":"(220 – 1000) mV"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Potencjał utleniająco-redukujący (redoks) wzgl. Ag/AgCl 3,5 mol KCl\nZakres (220 – 1000) mV\nMetoda potencjometryczna","reference":"PB-12 edycja 03 z dnia 02.01.2020 r.","norm_bases":["PB-12 edycja 03 z dnia 02.01.2020 r."],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi Potencjał utleniająco-redukujący (redoks) wzgl. Ag/AgCl 3,5 mol KCl\nZakres (220 – 1000) mV\nMetoda potencjometryczna PB-12 edycja 03 z dnia 02.01.2020 r. Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi Potencjal utleniajaco-redukujacy (redoks) wzgl. Ag/AgCl 3,5 mol KCl\nZakres (220 – 1000) mV\nMetoda potencjometryczna PB-12 edycja 03 z dnia 02.01.2020 r.","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxidation-reduction potential (redox) vs. Ag/AgCl 3,5 mol KCl","parameters_en":[{"name":"Range","range":"(220 – 1000) mV"}],"search_en":"Water (including swimming pool water), water intended for human consumption Oxidation-reduction potential (redox) vs. Ag/AgCl 3,5 mol KCl Potentiometric method Range PB-12 edycja 03 z dnia 02.01.2020 r.","technique_en":"Potentiometric method","test_object_en":"Water (including swimming pool water), water intended for human consumption","parameters_zh":[{"name":"范围","range":"(220 – 1000) mV"}],"search_zh":"水（含游泳池水）、生活饮用水 电位法 范围 PB-12 edycja 03 z dnia 02.01.2020 r.","technique_zh":"电位法","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a7f07a31995264369d8e0e9","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi, ścieki","methodology":"Stężenie chloru wolnego i ogólnego","parameters":[{"name":"Zakres","range":"(0,10 – 2,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru wolnego i ogólnego\nZakres (0,10 – 2,00) mg/l\nMetoda spektrofotometryczna","reference":"PB-11 edycja 03 z dnia 02.01.2020 r. w oparciu o test firmy Hach Lange 8021","norm_bases":["PB-11 edycja 03 z dnia 02.01.2020 r. w oparciu o test firmy Hach Lange 8021"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi, ścieki Stężenie chloru wolnego i ogólnego\nZakres (0,10 – 2,00) mg/l\nMetoda spektrofotometryczna PB-11 edycja 03 z dnia 02.01.2020 r. w oparciu o test firmy Hach Lange 8021 Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi, scieki Stezenie chloru wolnego i ogolnego\nZakres (0,10 – 2,00) mg/l\nMetoda spektrofotometryczna PB-11 edycja 03 z dnia 02.01.2020 r. w oparciu o test firmy Hach Lange 8021","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free and total chlorine concentration","parameters_en":[{"name":"Range","range":"(0,10 – 2,00) mg/l"}],"search_en":"Water (including, swimming pool water), water intended for human consumption, wastewater Free and total chlorine concentration Spectrophotometric method Range PB-11 edycja 03 z dnia 02.01.2020 r. w oparciu o test firmy Hach Lange 8021","technique_en":"Spectrophotometric method","test_object_en":"Water (including, swimming pool water), water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,10 – 2,00) mg/l"}],"search_zh":"水（含游泳池水）、生活饮用水、废水 游离氯与总氯浓度 分光光度法 范围 PB-11 edycja 03 z dnia 02.01.2020 r. w oparciu o test firmy Hach Lange 8021","technique_zh":"分光光度法","methodology_zh":"游离氯与总氯浓度","test_object_zh":"水（含游泳池水）、生活饮用水、废水"},{"_id":"6a7f07a31995264369d8e0ea","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi, ścieki","methodology":"Stężenie chloru związanego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chloru związanego (z obliczeń)","reference":"PB-11 edycja 03 z dnia 02.01.2020 r. w oparciu o test firmy Hach Lange 8021","norm_bases":["PB-11 edycja 03 z dnia 02.01.2020 r. w oparciu o test firmy Hach Lange 8021"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi, ścieki Stężenie chloru związanego (z obliczeń) PB-11 edycja 03 z dnia 02.01.2020 r. w oparciu o test firmy Hach Lange 8021 Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi, scieki Stezenie chloru zwiazanego (z obliczen) PB-11 edycja 03 z dnia 02.01.2020 r. w oparciu o test firmy Hach Lange 8021","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Combined chlorine concentration (calculated)","search_en":"Water (including, swimming pool water), water intended for human consumption, wastewater Combined chlorine concentration (calculated) PB-11 edycja 03 z dnia 02.01.2020 r. w oparciu o test firmy Hach Lange 8021","test_object_en":"Water (including, swimming pool water), water intended for human consumption, wastewater","methodology_zh":"化合氯浓度（计算值）","search_zh":"水（含游泳池水）、生活饮用水、废水 化合氯浓度（计算值） PB-11 edycja 03 z dnia 02.01.2020 r. w oparciu o test firmy Hach Lange 8021","test_object_zh":"水（含游泳池水）、生活饮用水、废水"},{"_id":"6a7f07a31995264369d8e0eb","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi, ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 − 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 − 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi, ścieki pH\nZakres 4,0 − 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi, scieki pH\nZakres 4,0 − 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 − 10,0"}],"search_en":"Water (including, swimming pool water), water intended for human consumption, wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water (including, swimming pool water), water intended for human consumption, wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 − 10,0"}],"search_zh":"水（含游泳池水）、生活饮用水、废水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水（含游泳池水）、生活饮用水、废水"},{"_id":"6a7f07a31995264369d8e0ec","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda opadowa, woda roztopowa","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda opadowa, woda roztopowa Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Woda opadowa, woda roztopowa Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Rainwater, snowmelt water Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11","technique_en":"Manual method; Automatic method","test_object_en":"Rainwater, snowmelt water","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 手动法；自动法 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法"},{"_id":"6a7f07a31995264369d8e0ed","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a7f07a31995264369d8e0ee","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Ścieki","methodology":"Temperatura pobranej próbki ścieków","parameters":[{"name":"Zakres","range":"(2,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura pobranej próbki ścieków\nZakres (2,0 – 50,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Temperatura pobranej próbki ścieków\nZakres (2,0 – 50,0) °C PN-77/C-04584 Scieki Temperatura pobranej probki sciekow\nZakres (2,0 – 50,0) °C PN-77/C-04584","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature of the collected wastewater sample","parameters_en":[{"name":"Range","range":"(2,0 – 50,0) °C"}],"search_en":"Wastewater Temperature of the collected wastewater sample Range PN-77/C-04584","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(2,0 – 50,0) °C"}],"search_zh":"污水 所采废水样品的温度 范围 PN-77/C-04584","test_object_zh":"污水","methodology_zh":"所采废水样品的温度"},{"_id":"6a7f07a31995264369d8e0ef","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu – ChZT- Cr","parameters":[{"name":"Zakres","range":"(40 – 15 000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu – ChZT- Cr\nZakres (40 – 15 000) mg/l O2\nMetoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu – ChZT- Cr\nZakres (40 – 15 000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006 Scieki Chemiczne zapotrzebowanie tlenu – ChZT- Cr\nZakres (40 – 15 000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(40 – 15 000) mg/l O2"}],"search_en":"Wastewater Titrimetric method Range PN-ISO 6060:2006","technique_en":"Titrimetric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(40 – 15 000) mg/l O2"}],"search_zh":"污水 滴定法 范围 PN-ISO 6060:2006","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a7f07a31995264369d8e0f0","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,05 − 3,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,05 − 3,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (0,05 − 3,00) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Scieki Stezenie azotu amonowego\nZakres (0,05 − 3,00) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,05 − 3,00) mg/l"}],"search_en":"Wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,05 − 3,00) mg/l"}],"search_zh":"污水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7f07a31995264369d8e0f1","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(2,0 − 500) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (2,0 − 500) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (2,0 − 500) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Scieki Stezenie azotu amonowego\nZakres (2,0 − 500) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(2,0 − 500) mg/l"}],"search_en":"Wastewater Ammonium nitrogen concentration Titrimetric method Range PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(2,0 − 500) mg/l"}],"search_zh":"污水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a7f07a31995264369d8e0f2","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,050 − 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,050 − 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001 pkt 7.1.1 +Ap1:2016-06","norm_bases":["PN-ISO 6332:2001 pkt 7.1.1 +Ap1:2016-06"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie żelaza ogólnego\nZakres (0,050 − 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 pkt 7.1.1 +Ap1:2016-06 Scieki Stezenie zelaza ogolnego\nZakres (0,050 − 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 pkt 7.1.1 +Ap1:2016-06","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,050 − 10,0) mg/l"}],"search_en":"Wastewater Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001 pkt 7.1.1 +Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,050 − 10,0) mg/l"}],"search_zh":"污水 总铁浓度 分光光度法 范围 PN-ISO 6332:2001 pkt 7.1.1 +Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7f07a31995264369d8e0f3","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda, ścieki, woda opadowa, woda roztopowa","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 − 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 − 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki, woda opadowa, woda roztopowa Zawiesiny ogólne\nZakres (2,0 − 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki, woda opadowa, woda roztopowa Zawiesiny ogolne\nZakres (2,0 − 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 − 2000) mg/l"}],"search_en":"Water, wastewater, rainwater, snowmelt water Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater, rainwater, snowmelt water","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 − 2000) mg/l"}],"search_zh":"总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法"},{"_id":"6a7f07a31995264369d8e0f4","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10 – 300) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10 – 300) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie siarczanów\nZakres (10 – 300) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, woda do spozycia przez ludzi, scieki Stezenie siarczanow\nZakres (10 – 300) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10 – 300) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 – 300) mg/l"}],"search_zh":"水、生活饮用水、污水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a7f07a31995264369d8e0f5","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 300) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 300) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie chlorków\nZakres (5,0 – 300) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, woda do spozycia przez ludzi, scieki Stezenie chlorkow\nZakres (5,0 – 300) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 300) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 300) mg/l"}],"search_zh":"水、生活饮用水、污水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a7f07a31995264369d8e0f6","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,10 − 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,10 − 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotanowego\nZakres (0,10 − 100) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda, scieki Stezenie azotu azotanowego\nZakres (0,10 − 100) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,10 − 100) mg/l"}],"search_en":"Water, wastewater Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576/08","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 − 100) mg/l"}],"search_zh":"水、废水 硝态氮浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a7f07a31995264369d8e0f7","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,010 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,010 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotynowego\nZakres (0,010 – 10,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego\nZakres (0,010 – 10,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,010 – 10,0) mg/l"}],"search_en":"Water, wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 10,0) mg/l"}],"search_zh":"水、废水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a7f07a31995264369d8e0f8","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(1,0 − 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (1,0 − 1000) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres (1,0 − 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla\nZakres (1,0 − 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,0 − 1000) mg/l"}],"search_en":"Water, wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 − 1000) mg/l"}],"search_zh":"水、废水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a7f07a31995264369d8e0f9","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-03 edycja 05 z dnia 02.01.2020 r.","norm_bases":["PB-03 edycja 05 z dnia 02.01.2020 r."],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu ogólnego (z obliczeń) PB-03 edycja 05 z dnia 02.01.2020 r. Woda, scieki Stezenie azotu ogolnego (z obliczen) PB-03 edycja 05 z dnia 02.01.2020 r.","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water, wastewater Total nitrogen concentration (calculated) PB-03 edycja 05 z dnia 02.01.2020 r.","test_object_en":"Water, wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"水、废水 总氮浓度（计算值） PB-03 edycja 05 z dnia 02.01.2020 r.","test_object_zh":"水、废水"},{"_id":"6a7f07a31995264369d8e0fa","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie substancji ekstrahujących się eterem naftowym","parameters":[{"name":"Zakres","range":"(10 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym\nZakres (10 – 1000) mg/l\nMetoda wagowa","reference":"PB-01 edycja 01 z dnia 01.10.2025 r.","norm_bases":["PB-01 edycja 01 z dnia 01.10.2025 r."],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie substancji ekstrahujących się eterem naftowym\nZakres (10 – 1000) mg/l\nMetoda wagowa PB-01 edycja 01 z dnia 01.10.2025 r. Woda, scieki Stezenie substancji ekstrahujacych sie eterem naftowym\nZakres (10 – 1000) mg/l\nMetoda wagowa PB-01 edycja 01 z dnia 01.10.2025 r.","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(10 – 1000) mg/l"}],"search_en":"Water, wastewater Concentration of substances extractable with petroleum ether Gravimetric method Range PB-01 edycja 01 z dnia 01.10.2025 r.","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(10 – 1000) mg/l"}],"search_zh":"水、废水 石油醚可萃取物浓度 重量法 范围 PB-01 edycja 01 z dnia 01.10.2025 r.","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"石油醚可萃取物浓度"},{"_id":"6a7f07a31995264369d8e0fb","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu – ChZT- Cr","parameters":[{"name":"Zakres","range":"(10,0 – 150) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu – ChZT- Cr\nZakres (10,0 – 150) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu – ChZT- Cr\nZakres (10,0 – 150) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu – ChZT- Cr\nZakres (10,0 – 150) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(10,0 – 150) mg/l O2"}],"search_en":"Water, wastewater Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(10,0 – 150) mg/l O2"}],"search_zh":"水、废水 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a7f07a31995264369d8e0fc","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu − BZT5","parameters":[{"name":"Zakres","range":"(1,0 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (1,0 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (1,0 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (1,0 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand − BOD5","parameters_en":[{"name":"Range","range":"(1,0 – 6,0) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand − BOD5 Electrochemical method Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(1,0 – 6,0) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a7f07a31995264369d8e0fd","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu − BZT5","parameters":[{"name":"Zakres","range":"(3 − 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (3 − 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (3 − 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (3 − 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand − BOD5","parameters_en":[{"name":"Range","range":"(3 − 6000) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand − BOD5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(3 − 6000) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a7f07a31995264369d8e0fe","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,060 − 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,060 − 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt 8 +Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt 8 +Ap1:2010 +Ap2:2010"],"lab_section":"Pracownia Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,060 − 100) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 8 +Ap1:2010 +Ap2:2010 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,060 − 100) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 8 +Ap1:2010 +Ap2:2010","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,060 − 100) mg/l"}],"search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 pkt 8 +Ap1:2010 +Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,060 − 100) mg/l"}],"search_zh":"水、废水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 pkt 8 +Ap1:2010 +Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a7f07a31995264369d8e0ff","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach, woda z kąpielisk), woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2, 4.4.4.2, 4.4.5, 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2, 4.4.4.2, 4.4.5, 4.4.6"],"lab_section":"Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach, woda z kąpielisk), woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2, 4.4.4.2, 4.4.5, 4.4.6 Woda (w tym, woda na plywalniach, woda z kapielisk), woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem pkt. 4.4.2, 4.4.4.2, 4.4.5, 4.4.6","categories":["water","microbiology"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Water (including swimming pool water, bathing water), water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2, 4.4.4.2, 4.4.5, 4.4.6","test_object_en":"Water (including swimming pool water, bathing water), water intended for human consumption","methodology_zh":"微生物检测用样品采集","search_zh":"微生物检测用样品采集 PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2, 4.4.4.2, 4.4.5, 4.4.6"},{"_id":"6a7f07a31995264369d8e100","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda, woda do spozycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of coliform bacteria","search_en":"Water, water intended for human consumption Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water, water intended for human consumption","methodology_zh":"大肠菌群最可能数（MPN）","search_zh":"水、生活饮用水 大肠菌群最可能数（MPN） 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水、生活饮用水"},{"_id":"6a7f07a31995264369d8e101","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba Escherichii coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba Escherichii coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Najbardziej prawdopodobna liczba Escherichii coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda, woda do spozycia przez ludzi Najbardziej prawdopodobna liczba Escherichii coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water, water intended for human consumption MPN method PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water, water intended for human consumption","search_zh":"水、生活饮用水 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水、生活饮用水"},{"_id":"6a7f07a31995264369d8e102","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda, woda do spozycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pseudomonas aeruginosa count","search_en":"Water, water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","technique_en":"Membrane filtration method","test_object_en":"Water, water intended for human consumption","methodology_zh":"铜绿假单胞菌计数","search_zh":"水、生活饮用水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f07a31995264369d8e103","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temp. 22 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temp. 22 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. 22 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. 22 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 22 °C","search_en":"Water, water intended for human consumption Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water, water intended for human consumption","search_zh":"水、生活饮用水 22 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水","methodology_zh":"22 °C 微生物总数"},{"_id":"6a7f07a31995264369d8e104","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temp. 36 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temp. 36 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. 36 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. 36 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total microorganism count at 36 °C","search_en":"Water, water intended for human consumption Total microorganism count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water, water intended for human consumption","search_zh":"水、生活饮用水 36 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水","methodology_zh":"36 °C 微生物总数"},{"_id":"6a7f07a31995264369d8e105","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Liczba Clostridium perfringens łącznie z przetrwalnikami","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Clostridium perfringens łącznie z przetrwalnikami\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":"Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Liczba Clostridium perfringens łącznie z przetrwalnikami\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda, woda do spozycia przez ludzi Liczba Clostridium perfringens lacznie z przetrwalnikami\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Clostridium perfringens count including spores","search_en":"Water, water intended for human consumption Clostridium perfringens count including spores Membrane filtration method PN-EN ISO 14189:2016-10","technique_en":"Membrane filtration method","test_object_en":"Water, water intended for human consumption","search_zh":"水、生活饮用水 产气荚膜梭菌数（含芽孢） 膜过滤法 PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","methodology_zh":"产气荚膜梭菌数（含芽孢）"},{"_id":"6a7f07a31995264369d8e106","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Water, water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water, water intended for human consumption","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f07a31995264369d8e107","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda (w tym woda z kąpielisk), woda do spożycia przez ludzi","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda z kąpielisk), woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda (w tym woda z kapielisk), woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count","search_en":"Water (including bathing water), water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water (including bathing water), water intended for human consumption","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水（含浴场水）、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水（含浴场水）、生活饮用水"},{"_id":"6a7f07a31995264369d8e108","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda (w tym woda z kąpielisk), woda do spożycia przez ludzi","methodology":"Liczba Enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda z kąpielisk), woda do spożycia przez ludzi Liczba Enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda (w tym woda z kapielisk), woda do spozycia przez ludzi Liczba Enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Intestinal enterococci count","search_en":"Water (including bathing water), water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water (including bathing water), water intended for human consumption","search_zh":"水（含浴场水）、生活饮用水 粪肠球菌数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","methodology_zh":"粪肠球菌数","test_object_zh":"水（含浴场水）、生活饮用水"},{"_id":"6a7f07a31995264369d8e109","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Ogólna liczba mikroorganizmów w temp. 36 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temp. 36 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Ogólna liczba mikroorganizmów w temp. 36 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda na plywalniach Ogolna liczba mikroorganizmow w temp. 36 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total microorganism count at 36 °C","search_en":"Swimming pool water Total microorganism count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Swimming pool water","search_zh":"游泳池水 36 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"游泳池水","methodology_zh":"36 °C 微生物总数"},{"_id":"6a7f07a31995264369d8e10a","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 + A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 + A1:2017-04"],"lab_section":"Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 + A1:2017-04 Woda na plywalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 + A1:2017-04","categories":["water","microbiology"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count","search_en":"Swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 + A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Swimming pool water","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"游泳池水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 + A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"游泳池水"},{"_id":"6a7f07a31995264369d8e10b","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Najbardziej prawdopodobna liczba Escherichia coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Najbardziej prawdopodobna liczba Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda na plywalniach Najbardziej prawdopodobna liczba Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of Escherichia coli","search_en":"Swimming pool water Most probable number of Escherichia coli MPN method PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Swimming pool water","search_zh":"游泳池水 大肠埃希氏菌最可能数 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"游泳池水","methodology_zh":"大肠埃希氏菌最可能数"},{"_id":"6a7f07a31995264369d8e10c","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda na plywalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pseudomonas aeruginosa count","search_en":"Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","technique_en":"Membrane filtration method","test_object_en":"Swimming pool water","methodology_zh":"铜绿假单胞菌计数","search_zh":"游泳池水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"游泳池水"},{"_id":"6a7f07a31995264369d8e10d","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba bakterii z rodzaju Legionella sp. Matryca A, Procedura 5, Pożywka A-BCYE Matryca A, Procedura 7, Pożywka C-GVPC Matryca B, Procedura 7, Pożywka C-GVPC","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii z rodzaju Legionella sp. Matryca A, Procedura 5, Pożywka A-BCYE Matryca A, Procedura 7, Pożywka C-GVPC Matryca B, Procedura 7, Pożywka C-GVPC\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 +Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 +Ap1:2019-12"],"lab_section":"Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba bakterii z rodzaju Legionella sp. Matryca A, Procedura 5, Pożywka A-BCYE Matryca A, Procedura 7, Pożywka C-GVPC Matryca B, Procedura 7, Pożywka C-GVPC\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12 Woda na plywalniach Liczba bakterii z rodzaju Legionella sp. Matryca A, Procedura 5, Pozywka A-BCYE Matryca A, Procedura 7, Pozywka C-GVPC Matryca B, Procedura 7, Pozywka C-GVPC\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12","categories":["microbiology","water"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Swimming pool water Membrane filtration method PN-EN ISO 11731:2017-08 +Ap1:2019-12","technique_en":"Membrane filtration method","test_object_en":"Swimming pool water","search_zh":"游泳池水 膜过滤法 PN-EN ISO 11731:2017-08 +Ap1:2019-12","technique_zh":"膜过滤法","test_object_zh":"游泳池水"},{"_id":"6a7f07a31995264369d8e10e","lab_id":"69ad52a3de79e566650fb552","country":"PL","accr_number":"AB 1047","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii z rodzaju Legionella sp. Matryca A, Procedura 5, Pożywka A-BCYE Matryca A, Procedura 7, Pożywka C-GVPC Matryca B, Procedura 7, Pożywka C-GVPC","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii z rodzaju Legionella sp. Matryca A, Procedura 5, Pożywka A-BCYE Matryca A, Procedura 7, Pożywka C-GVPC Matryca B, Procedura 7, Pożywka C-GVPC\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 +Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 +Ap1:2019-12"],"lab_section":"Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii z rodzaju Legionella sp. Matryca A, Procedura 5, Pożywka A-BCYE Matryca A, Procedura 7, Pożywka C-GVPC Matryca B, Procedura 7, Pożywka C-GVPC\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12 Woda do spozycia przez ludzi Liczba bakterii z rodzaju Legionella sp. Matryca A, Procedura 5, Pozywka A-BCYE Matryca A, Procedura 7, Pozywka C-GVPC Matryca B, Procedura 7, Pozywka C-GVPC\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12","categories":["microbiology","water"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water intended for human consumption Membrane filtration method PN-EN ISO 11731:2017-08 +Ap1:2019-12","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 膜过滤法 PN-EN ISO 11731:2017-08 +Ap1:2019-12","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"}],"has_pdf":true}