{"lab":{"_id":"69ad52a3de79e566650fb54c","accr_number":"AB 1044","country":"PL","accr_body":"PCA","address":"LABORATORIUM, ul. Guzewska 14, 95-030 Rzgów","categories":["water","environment","materials"],"city":"Rzgów","imported_at":"2026-03-08T10:42:43.265Z","methods_count":77,"name":"EKO-KOMPLEKS J. Fidrysiak, J. Budzińska S.J.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1044.pdf"],"scope_summary":"","search_text":"eko-kompleks j. fidrysiak, j. budzińska s.j. laboratorium, ul. guzewska 14, 95-030 rzgów water other food materials pharma electronics microbiology environment","status":"active","updated_at":"2026-03-08T14:50:13.648Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-14T12:17:01.106Z","parse_date":"2026-08-14T12:17:01.106Z","parse_source":"agent-claude-code","email_confidence":"high","email_mx":true,"email_source":"https://ekokompleks.com.pl/kontakt/","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P; C/31/P; C/32/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, gleby, osadów, odpadów","en":"Chemical tests and sampling of water, drinking water, sewage, soil, sediments, waste"},{"codes":"C/28; C/31","pl":"Badania chemiczne wody, gleby","en":"Chemical tests and sampling of water, soil"},{"codes":"N/28/P; N/29/P; N/30/P; N/31/P; N/32/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, gleby, osadów, odpadów","en":"Tests of physical properties and sampling of water, drinking water, sewage, soil, sediments, waste"},{"codes":"N/28; N/31","pl":"Badania właściwości fizycznych wody, gleby","en":"Tests of physical properties of water, soil"},{"codes":"P/29","pl":"Pobieranie próbek wody do spożycia przez ludzi","en":"Sampling of drinking water"},{"codes":"P/32","pl":"Pobieranie próbek osadów, odpadów","en":"Sampling of sediments, waste"}],"issue":{"no":"21","date":"03.08.2026"},"map_coord":[51.656864,19.464498],"map_geo":"nominatim-street","lab_locations":[{"name":"Laboratorium","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/14/ac6e611e166c2837e8157be58e8795d5/AB%201044.pdf","has_en":true,"category_counts":{"water":71,"environment":14,"materials":5,"petro":2,"microbiology":2},"category_scores":{"water":53.63,"environment":2.09,"materials":0.27,"petro":0.04,"microbiology":0.04},"has_zh":true,"lab_locations_zh":[{"name":"实验室","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7f073d5decf8eaf531b2ee","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,05 – 60,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,05 – 60,0) mg/l\nMetoda spektrofotometryczna","reference":"PB nr 31/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 302, 303, 304","norm_bases":["PB nr 31/2012 wydanie 1 z dnia 02.01.2012 r.","na podstawie testu kuwetowego Hach-Lange nr LCK 302, 303, 304"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,05 – 60,0) mg/l\nMetoda spektrofotometryczna PB nr 31/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 302, 303, 304 Woda, woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,05 – 60,0) mg/l\nMetoda spektrofotometryczna PB nr 31/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 302, 303, 304","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,05 – 60,0) mg/l"}],"search_en":"Water, water intended for human consumption Ammonium ion concentration Spectrophotometric method Laboratory Range PB nr 31/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 302, 303, 304","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 60,0) mg/l"}],"search_zh":"水、生活饮用水 铵离子浓度 分光光度法 实验室 范围 PB nr 31/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 302, 303, 304","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f073d5decf8eaf531b2ef","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,05 – 20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,05 – 20) mg/l\nMetoda spektrofotometryczna","reference":"PB nr 32/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 341, 342","norm_bases":["PB nr 32/2012 wydanie 1 z dnia 02.01.2012 r.","na podstawie testu kuwetowego Hach-Lange nr LCK 341, 342"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,05 – 20) mg/l\nMetoda spektrofotometryczna PB nr 32/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 341, 342 Woda, woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,05 – 20) mg/l\nMetoda spektrofotometryczna PB nr 32/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 341, 342","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,05 – 20) mg/l"}],"search_en":"Water, water intended for human consumption Nitrite concentration Spectrophotometric method Laboratory Range PB nr 32/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 341, 342","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 20) mg/l"}],"search_zh":"水、生活饮用水 亚硝酸盐浓度 分光光度法 实验室 范围 PB nr 32/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 341, 342","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f073d5decf8eaf531b2f0","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(1 – 155) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (1 – 155) mg/l\nMetoda spektrofotometryczna","reference":"PB nr 33/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 339, 340","norm_bases":["PB nr 33/2012 wydanie 1 z dnia 02.01.2012 r.","na podstawie testu kuwetowego Hach-Lange nr LCK 339, 340"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotanów\nZakres (1 – 155) mg/l\nMetoda spektrofotometryczna PB nr 33/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 339, 340 Woda, woda do spozycia przez ludzi Stezenie azotanow\nZakres (1 – 155) mg/l\nMetoda spektrofotometryczna PB nr 33/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 339, 340","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(1 – 155) mg/l"}],"search_en":"Water, water intended for human consumption Nitrate concentration Spectrophotometric method Laboratory Range PB nr 33/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 339, 340","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(1 – 155) mg/l"}],"search_zh":"水、生活饮用水 硝酸盐浓度 分光光度法 实验室 范围 PB nr 33/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 339, 340","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f073d5decf8eaf531b2f1","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,015 – 0,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (0,015 – 0,5) mg/l\nMetoda spektrofotometryczna","reference":"PB nr 01/2019 wydanie 1 z dnia 23.04.2019 r. | na podstawie testu kuwetowego Hach LCW 532","norm_bases":["PB nr 01/2019 wydanie 1 z dnia 23.04.2019 r.","na podstawie testu kuwetowego Hach LCW 532"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie manganu\nZakres (0,015 – 0,5) mg/l\nMetoda spektrofotometryczna PB nr 01/2019 wydanie 1 z dnia 23.04.2019 r. | na podstawie testu kuwetowego Hach LCW 532 Woda, woda do spozycia przez ludzi Stezenie manganu\nZakres (0,015 – 0,5) mg/l\nMetoda spektrofotometryczna PB nr 01/2019 wydanie 1 z dnia 23.04.2019 r. | na podstawie testu kuwetowego Hach LCW 532","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(0,015 – 0,5) mg/l"}],"search_en":"Water, water intended for human consumption Manganese concentration Spectrophotometric method Laboratory Range PB nr 01/2019 wydanie 1 z dnia 23.04.2019 r. | na podstawie testu kuwetowego Hach LCW 532","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,015 – 0,5) mg/l"}],"search_zh":"水、生活饮用水 锰浓度 分光光度法 实验室 范围 PB nr 01/2019 wydanie 1 z dnia 23.04.2019 r. | na podstawie testu kuwetowego Hach LCW 532","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f073d5decf8eaf531b2f2","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,1 – 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,1 – 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Mętność\nZakres (0,1 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, woda do spozycia przez ludzi Metnosc\nZakres (0,1 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,1 – 100) NTU"}],"search_en":"Water, water intended for human consumption Turbidity Nephelometric method Laboratory Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,1 – 100) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 实验室 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水"},{"_id":"6a7f073d5decf8eaf531b2f3","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(5 – 5000) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5 – 5000) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5 – 5000) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (5 – 5000) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(5 – 5000) mg/l CaCO3"}],"search_en":"Water, water intended for human consumption Total content of calcium and magnesium (total hardness) Titrimetric method Laboratory Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(5 – 5000) mg/l CaCO3"}],"search_zh":"水、生活饮用水 钙与镁总量（总硬度） 滴定法 实验室 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f073d5decf8eaf531b2f4","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie chlorków\nZakres (5,0 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, woda do spozycia przez ludzi Stezenie chlorkow\nZakres (5,0 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 1000) mg/l"}],"search_en":"Water, water intended for human consumption Chloride concentration Titrimetric method Laboratory Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 1000) mg/l"}],"search_zh":"水、生活饮用水 氯化物浓度 滴定法 实验室 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f073d5decf8eaf531b2f5","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(0,01 – 5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (0,01 – 5) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie żelaza\nZakres (0,01 – 5) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda, woda do spozycia przez ludzi Stezenie zelaza\nZakres (0,01 – 5) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(0,01 – 5) mg/l"}],"search_en":"Water, water intended for human consumption Iron concentration Spectrophotometric method Laboratory Range PN-ISO 6332:2001+Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(0,01 – 5) mg/l"}],"search_zh":"水、生活饮用水 铁浓度 分光光度法 实验室 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f073d5decf8eaf531b2f6","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Wody opadowe, wody roztopowe","methodology":"Pobieranie próbek do badań fizycznych i chemicznych","parameters":[],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody opadowe, wody roztopowe Pobieranie próbek do badań fizycznych i chemicznych\nMetoda manualna PN-ISO 5667-10:2021-11 Wody opadowe, wody roztopowe Pobieranie probek do badan fizycznych i chemicznych\nMetoda manualna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for physical and chemical testing","search_en":"Rainwater, snowmelt water Sampling for physical and chemical testing Manual method Laboratory PN-ISO 5667-10:2021-11","technique_en":"Manual method","test_object_en":"Rainwater, snowmelt water","lab_section_zh":"实验室","methodology_zh":"物理与化学检测用样品采集","search_zh":"雨水、融雪水 物理与化学检测用样品采集 手工法 实验室 PN-ISO 5667-10:2021-11","test_object_zh":"雨水、融雪水","technique_zh":"手工法"},{"_id":"6a7f073d5decf8eaf531b2f7","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Wody opadowe, wody roztopowe","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 10000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 10000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody opadowe, wody roztopowe Zawiesiny ogólne\nZakres (2,0 – 10000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Wody opadowe, wody roztopowe Zawiesiny ogolne\nZakres (2,0 – 10000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 10000) mg/l"}],"search_en":"Rainwater, snowmelt water Total suspended solids (TSS) Gravimetric method Laboratory Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Rainwater, snowmelt water","lab_section_zh":"实验室","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 10000) mg/l"}],"search_zh":"雨水、融雪水 总悬浮物 重量法 实验室 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"雨水、融雪水"},{"_id":"6a7f073d5decf8eaf531b2f8","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Wody opadowe, wody roztopowe","methodology":"Indeks oleju mineralnego","parameters":[{"name":"Zakres","range":"(0,10 – 20) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Indeks oleju mineralnego\nZakres (0,10 – 20) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody opadowe, wody roztopowe Indeks oleju mineralnego\nZakres (0,10 – 20) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Wody opadowe, wody roztopowe Indeks oleju mineralnego\nZakres (0,10 – 20) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Mineral oil index","parameters_en":[{"name":"Range","range":"(0,10 – 20) mg/l"}],"search_en":"Rainwater, snowmelt water Mineral oil index Gas chromatography with flame ionization detection (GC-FID) Laboratory Range PN-EN ISO 9377-2:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Rainwater, snowmelt water","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,10 – 20) mg/l"}],"search_zh":"雨水、融雪水 矿物油指数 气相色谱-氢火焰离子化检测法（GC-FID） 实验室 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"雨水、融雪水","methodology_zh":"矿物油指数"},{"_id":"6a7f073d5decf8eaf531b2f9","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań fizycznych i chemicznych","parameters":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań fizycznych i chemicznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan fizycznych i chemicznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for physical and chemical testing","search_en":"Wastewater Sampling for physical and chemical testing Manual method; Automatic method Laboratory PN-ISO 5667-10:2021-11","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"物理与化学检测用样品采集","search_zh":"污水 物理与化学检测用样品采集 手动法；自动法 实验室 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a7f073d5decf8eaf531b2fa","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Ścieki","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(1,0 – 50,0)°C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (1,0 – 50,0)°C","reference":"PB nr 02/2008 wydanie 1 z dnia 15.09.2008 r.","norm_bases":["PB nr 02/2008 wydanie 1 z dnia 15.09.2008 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Temperatura\nZakres (1,0 – 50,0)°C PB nr 02/2008 wydanie 1 z dnia 15.09.2008 r. Scieki Temperatura\nZakres (1,0 – 50,0)°C PB nr 02/2008 wydanie 1 z dnia 15.09.2008 r.","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(1,0 – 50,0)°C"}],"search_en":"Wastewater Temperature Laboratory Range PB nr 02/2008 wydanie 1 z dnia 15.09.2008 r.","test_object_en":"Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(1,0 – 50,0)°C"}],"search_zh":"污水 温度 实验室 范围 PB nr 02/2008 wydanie 1 z dnia 15.09.2008 r.","test_object_zh":"污水","methodology_zh":"温度"},{"_id":"6a7f073d5decf8eaf531b2fb","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(1,0 – 250) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (1,0 – 250) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (1,0 – 250) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Scieki Stezenie azotu amonowego\nZakres (1,0 – 250) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,0 – 250) mg/l"}],"search_en":"Wastewater Ammonium nitrogen concentration Titrimetric method Laboratory Range PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 250) mg/l"}],"search_zh":"污水 氨氮浓度 滴定法 实验室 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a7f073d5decf8eaf531b2fc","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Ścieki","methodology":"Substancje ekstrahujące się eterem naftowym","parameters":[{"name":"Zakres","range":"(10,0 – 1500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje ekstrahujące się eterem naftowym\nZakres (10,0 – 1500) mg/l\nMetoda wagowa","reference":"PB nr 01/2025 wydanie 1 z dnia 11.01.2025 r.","norm_bases":["PB nr 01/2025 wydanie 1 z dnia 11.01.2025 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Substancje ekstrahujące się eterem naftowym\nZakres (10,0 – 1500) mg/l\nMetoda wagowa PB nr 01/2025 wydanie 1 z dnia 11.01.2025 r. Scieki Substancje ekstrahujace sie eterem naftowym\nZakres (10,0 – 1500) mg/l\nMetoda wagowa PB nr 01/2025 wydanie 1 z dnia 11.01.2025 r.","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(10,0 – 1500) mg/l"}],"search_en":"Wastewater Substances extractable with petroleum ether Gravimetric method Laboratory Range PB nr 01/2025 wydanie 1 z dnia 11.01.2025 r.","technique_en":"Gravimetric method","test_object_en":"Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(10,0 – 1500) mg/l"}],"search_zh":"污水 石油醚可萃取物 重量法 实验室 范围 PB nr 01/2025 wydanie 1 z dnia 11.01.2025 r.","technique_zh":"重量法","test_object_zh":"污水","methodology_zh":"石油醚可萃取物"},{"_id":"6a7f073d5decf8eaf531b2fd","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,1 – 130) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,1 – 130) mg/l\nMetoda spektrofotometryczna","reference":"PB nr 31/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 302, 303, 304","norm_bases":["PB nr 31/2012 wydanie 1 z dnia 02.01.2012 r.","na podstawie testu kuwetowego Hach-Lange nr LCK 302, 303, 304"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (0,1 – 130) mg/l\nMetoda spektrofotometryczna PB nr 31/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 302, 303, 304 Scieki Stezenie azotu amonowego\nZakres (0,1 – 130) mg/l\nMetoda spektrofotometryczna PB nr 31/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 302, 303, 304","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,1 – 130) mg/l"}],"search_en":"Wastewater Ammonium nitrogen concentration Spectrophotometric method Laboratory Range PB nr 31/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 302, 303, 304","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,1 – 130) mg/l"}],"search_zh":"污水 氨氮浓度 分光光度法 实验室 范围 PB nr 31/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 302, 303, 304","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7f073d5decf8eaf531b2fe","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,015 – 6) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,015 – 6) mg/l\nMetoda spektrofotometryczna","reference":"PB nr 32/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 341, 342","norm_bases":["PB nr 32/2012 wydanie 1 z dnia 02.01.2012 r.","na podstawie testu kuwetowego Hach-Lange nr LCK 341, 342"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotynowego\nZakres (0,015 – 6) mg/l\nMetoda spektrofotometryczna PB nr 32/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 341, 342 Scieki Stezenie azotu azotynowego\nZakres (0,015 – 6) mg/l\nMetoda spektrofotometryczna PB nr 32/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 341, 342","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,015 – 6) mg/l"}],"search_en":"Wastewater Nitrite nitrogen concentration Spectrophotometric method Laboratory Range PB nr 32/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 341, 342","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,015 – 6) mg/l"}],"search_zh":"污水 亚硝态氮浓度 分光光度法 实验室 范围 PB nr 32/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 341, 342","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7f073d5decf8eaf531b2ff","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,23 – 35) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,23 – 35) mg/l\nMetoda spektrofotometryczna","reference":"PB nr 33/2012 Wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 339, 340","norm_bases":["PB nr 33/2012 Wydanie 1 z dnia 02.01.2012 r.","na podstawie testu kuwetowego Hach-Lange nr LCK 339, 340"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotanowego\nZakres (0,23 – 35) mg/l\nMetoda spektrofotometryczna PB nr 33/2012 Wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 339, 340 Scieki Stezenie azotu azotanowego\nZakres (0,23 – 35) mg/l\nMetoda spektrofotometryczna PB nr 33/2012 Wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 339, 340","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,23 – 35) mg/l"}],"search_en":"Wastewater Nitrate nitrogen concentration Spectrophotometric method Laboratory Range PB nr 33/2012 Wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 339, 340","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,23 – 35) mg/l"}],"search_zh":"污水 硝态氮浓度 分光光度法 实验室 范围 PB nr 33/2012 Wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 339, 340","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7f073d5decf8eaf531b300","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,5 – 20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,5 – 20) mg/l\nMetoda spektrofotometryczna","reference":"PB nr 30/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 348, 350","norm_bases":["PB nr 30/2012 wydanie 1 z dnia 02.01.2012 r.","na podstawie testu kuwetowego Hach-Lange nr LCK 348, 350"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,5 – 20) mg/l\nMetoda spektrofotometryczna PB nr 30/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 348, 350 Scieki Stezenie fosforu ogolnego\nZakres (0,5 – 20) mg/l\nMetoda spektrofotometryczna PB nr 30/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 348, 350","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,5 – 20) mg/l"}],"search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Laboratory Range PB nr 30/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 348, 350","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,5 – 20) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 实验室 范围 PB nr 30/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 348, 350","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7f073d5decf8eaf531b301","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie metali","parameters":[{"name":"Ni","range":"(0,10 – 10) mg/l"},{"name":"Zn","range":"(0,050 – 2) mg/l"},{"name":"Cd","range":"(0,020 – 2) mg/l"},{"name":"Pb","range":"(0,20 – 10) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie metali\nZakres:\nNi (0,10 – 10) mg/l\nZn (0,050 – 2) mg/l\nCd (0,020 – 2) mg/l\nPb (0,20 – 10) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 metoda A","norm_bases":["PN-ISO 8288:2002 metoda A"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie metali\nZakres:\nNi (0,10 – 10) mg/l\nZn (0,050 – 2) mg/l\nCd (0,020 – 2) mg/l\nPb (0,20 – 10) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A Scieki Stezenie metali\nZakres:\nNi (0,10 – 10) mg/l\nZn (0,050 – 2) mg/l\nCd (0,020 – 2) mg/l\nPb (0,20 – 10) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A","categories":["materials","water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Metal concentrations","parameters_en":[{"name":"Ni","range":"(0,10 – 10) mg/l"},{"name":"Zn","range":"(0,050 – 2) mg/l"},{"name":"Cd","range":"(0,020 – 2) mg/l"},{"name":"Pb","range":"(0,20 – 10) mg/l"}],"search_en":"Wastewater Metal concentrations Flame atomic absorption spectrometry (FAAS) Laboratory Ni Zn Cd Pb PN-ISO 8288:2002 metoda A","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"金属浓度","parameters_zh":[{"name":"Ni","range":"(0,10 – 10) mg/l"},{"name":"Zn","range":"(0,050 – 2) mg/l"},{"name":"Cd","range":"(0,020 – 2) mg/l"},{"name":"Pb","range":"(0,20 – 10) mg/l"}],"search_zh":"污水 金属浓度 火焰原子吸收光谱法（FAAS） 实验室 Ni Zn Cd Pb PN-ISO 8288:2002 metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"污水"},{"_id":"6a7f073d5decf8eaf531b302","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chromu","parameters":[{"name":"Zakres","range":"(0,10 – 20) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie chromu\nZakres (0,10 – 20) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 1233:2000 p.3","norm_bases":["PN-EN 1233:2000 p.3"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chromu\nZakres (0,10 – 20) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 1233:2000 p.3 Scieki Stezenie chromu\nZakres (0,10 – 20) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 1233:2000 p.3","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chromium concentration","parameters_en":[{"name":"Range","range":"(0,10 – 20) mg/l"}],"search_en":"Wastewater Chromium concentration Flame atomic absorption spectrometry (FAAS) Laboratory Range PN-EN 1233:2000 p.3","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,10 – 20) mg/l"}],"search_zh":"污水 铬浓度 火焰原子吸收光谱法（FAAS） 实验室 范围 PN-EN 1233:2000 p.3","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"污水","methodology_zh":"铬浓度"},{"_id":"6a7f073d5decf8eaf531b303","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(1,0 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (1,0 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PB nr 06/2019 wydanie 2 z dnia 04.11.2019 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 138, 238, 338","norm_bases":["PB nr 06/2019 wydanie 2 z dnia 04.11.2019 r.","na podstawie testu kuwetowego Hach-Lange nr LCK 138, 238, 338"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego\nZakres (1,0 – 100) mg/l\nMetoda spektrofotometryczna PB nr 06/2019 wydanie 2 z dnia 04.11.2019 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 138, 238, 338 Scieki Stezenie azotu ogolnego\nZakres (1,0 – 100) mg/l\nMetoda spektrofotometryczna PB nr 06/2019 wydanie 2 z dnia 04.11.2019 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 138, 238, 338","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,0 – 100) mg/l"}],"search_en":"Wastewater Total nitrogen concentration Spectrophotometric method Laboratory Range PB nr 06/2019 wydanie 2 z dnia 04.11.2019 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 138, 238, 338","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 100) mg/l"}],"search_zh":"污水 总氮浓度 分光光度法 实验室 范围 PB nr 06/2019 wydanie 2 z dnia 04.11.2019 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 138, 238, 338","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7f073d5decf8eaf531b304","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 4000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 4000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chlorków\nZakres (5,0 – 4000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki Stezenie chlorkow\nZakres (5,0 – 4000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 4000) mg/l"}],"search_en":"Wastewater Chloride concentration Titrimetric method Laboratory Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 4000) mg/l"}],"search_zh":"污水 氯化物浓度 滴定法 实验室 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a7f073d5decf8eaf531b305","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(0,01 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (0,01 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie żelaza\nZakres (0,01 – 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Scieki Stezenie zelaza\nZakres (0,01 – 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(0,01 – 10,0) mg/l"}],"search_en":"Wastewater Iron concentration Spectrophotometric method Laboratory Range PN-ISO 6332:2001+Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(0,01 – 10,0) mg/l"}],"search_zh":"污水 铁浓度 分光光度法 实验室 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7f073d5decf8eaf531b306","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chromu (VI)","parameters":[{"name":"Zakres","range":"(0,010 – 5,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chromu (VI)\nZakres (0,010 – 5,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-77/C-04604/08","norm_bases":["PN-77/C-04604/08"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chromu (VI)\nZakres (0,010 – 5,00) mg/l\nMetoda spektrofotometryczna PN-77/C-04604/08 Scieki Stezenie chromu (VI)\nZakres (0,010 – 5,00) mg/l\nMetoda spektrofotometryczna PN-77/C-04604/08","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chromium(VI) concentration","parameters_en":[{"name":"Range","range":"(0,010 – 5,00) mg/l"}],"search_en":"Wastewater Chromium(VI) concentration Spectrophotometric method Laboratory Range PN-77/C-04604/08","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,010 – 5,00) mg/l"}],"search_zh":"污水 六价铬浓度 分光光度法 实验室 范围 PN-77/C-04604/08","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"六价铬浓度"},{"_id":"6a7f073d5decf8eaf531b307","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 10000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 10000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (2,0 – 10000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (2,0 – 10000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 10000) mg/l"}],"search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Laboratory Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","lab_section_zh":"实验室","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 10000) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 实验室 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a7f073d5decf8eaf531b308","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie metali","parameters":[{"name":"Fe","range":"(0,20 – 10) mg/l"},{"name":"Cu","range":"(0,050 – 6) mg/l"},{"name":"Mn","range":"(0,050 – 1) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie metali\nZakres:\nFe (0,20 – 10) mg/l\nCu (0,050 – 6) mg/l\nMn (0,050 – 1) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB nr 23/2010 wydanie 1 z dnia 11.02.2010 r.","norm_bases":["PB nr 23/2010 wydanie 1 z dnia 11.02.2010 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie metali\nZakres:\nFe (0,20 – 10) mg/l\nCu (0,050 – 6) mg/l\nMn (0,050 – 1) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB nr 23/2010 wydanie 1 z dnia 11.02.2010 r. Woda, scieki Stezenie metali\nZakres:\nFe (0,20 – 10) mg/l\nCu (0,050 – 6) mg/l\nMn (0,050 – 1) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB nr 23/2010 wydanie 1 z dnia 11.02.2010 r.","categories":["water","materials"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Metal concentrations","parameters_en":[{"name":"Fe","range":"(0,20 – 10) mg/l"},{"name":"Cu","range":"(0,050 – 6) mg/l"},{"name":"Mn","range":"(0,050 – 1) mg/l"}],"search_en":"Water, wastewater Metal concentrations Flame atomic absorption spectrometry (FAAS) Laboratory Fe Cu Mn PB nr 23/2010 wydanie 1 z dnia 11.02.2010 r.","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water, wastewater","lab_section_zh":"实验室","methodology_zh":"金属浓度","parameters_zh":[{"name":"Fe","range":"(0,20 – 10) mg/l"},{"name":"Cu","range":"(0,050 – 6) mg/l"},{"name":"Mn","range":"(0,050 – 1) mg/l"}],"search_zh":"水、废水 金属浓度 火焰原子吸收光谱法（FAAS） 实验室 Fe Cu Mn PB nr 23/2010 wydanie 1 z dnia 11.02.2010 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、废水"},{"_id":"6a7f073d5decf8eaf531b309","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforanów","parameters":[{"name":"Zakres","range":"(1,5 – 60) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforanów\nZakres (1,5 – 60) mg/l\nMetoda spektrofotometryczna","reference":"PB nr 30/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 348, 350","norm_bases":["PB nr 30/2012 wydanie 1 z dnia 02.01.2012 r.","na podstawie testu kuwetowego Hach-Lange nr LCK 348, 350"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforanów\nZakres (1,5 – 60) mg/l\nMetoda spektrofotometryczna PB nr 30/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 348, 350 Woda, scieki Stezenie fosforanow\nZakres (1,5 – 60) mg/l\nMetoda spektrofotometryczna PB nr 30/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 348, 350","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Phosphate concentration","parameters_en":[{"name":"Range","range":"(1,5 – 60) mg/l"}],"search_en":"Water, wastewater Phosphate concentration Spectrophotometric method Laboratory Range PB nr 30/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 348, 350","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(1,5 – 60) mg/l"}],"search_zh":"水、废水 磷酸盐浓度 分光光度法 实验室 范围 PB nr 30/2012 wydanie 1 z dnia 02.01.2012 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 348, 350","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"磷酸盐浓度"},{"_id":"6a7f073d5decf8eaf531b30a","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu","parameters":[{"name":"ChZT"},{"name":"Zakres","range":"(5,0 – 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (5,0 – 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (5,0 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (5,0 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chemical oxygen demand","parameters_en":[{"name":"COD"},{"name":"Range","range":"(5,0 – 10000) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand Spectrophotometric method Laboratory COD Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"化学需氧量（COD）"},{"name":"范围","range":"(5,0 – 10000) mg/l O2"}],"search_zh":"水、废水 化学需氧量（COD） 分光光度法 实验室 化学需氧量（COD） 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a7f073d5decf8eaf531b30b","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu","parameters":[{"name":"ChZT"},{"name":"Zakres","range":"(5,0 – 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (5,0 – 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PB nr 36/2015 wydanie 1 z dn. 18.03.2015 r. | na podstawie testów kuwetowych Hach-Lange nr LCK 414, 314, 114, 014","norm_bases":["PB nr 36/2015 wydanie 1 z dn. 18.03.2015 r.","na podstawie testów kuwetowych Hach-Lange nr LCK 414, 314, 114, 014"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (5,0 – 10000) mg/l O2\nMetoda spektrofotometryczna PB nr 36/2015 wydanie 1 z dn. 18.03.2015 r. | na podstawie testów kuwetowych Hach-Lange nr LCK 414, 314, 114, 014 Woda, scieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (5,0 – 10000) mg/l O2\nMetoda spektrofotometryczna PB nr 36/2015 wydanie 1 z dn. 18.03.2015 r. | na podstawie testow kuwetowych Hach-Lange nr LCK 414, 314, 114, 014","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chemical oxygen demand","parameters_en":[{"name":"COD"},{"name":"Range","range":"(5,0 – 10000) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand Spectrophotometric method Laboratory COD Range PB nr 36/2015 wydanie 1 z dn. 18.03.2015 r. | na podstawie testów kuwetowych Hach-Lange nr LCK 414, 314, 114, 014","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"化学需氧量（COD）"},{"name":"范围","range":"(5,0 – 10000) mg/l O2"}],"search_zh":"水、废水 化学需氧量（COD） 分光光度法 实验室 化学需氧量（COD） 范围 PB nr 36/2015 wydanie 1 z dn. 18.03.2015 r. | na podstawie testów kuwetowych Hach-Lange nr LCK 414, 314, 114, 014","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a7f073d5decf8eaf531b30c","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Indeks oleju mineralnego","parameters":[{"name":"Zakres","range":"(0,10 – 20) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Indeks oleju mineralnego\nZakres (0,10 – 20) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Indeks oleju mineralnego\nZakres (0,10 – 20) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda, scieki Indeks oleju mineralnego\nZakres (0,10 – 20) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Mineral oil index","parameters_en":[{"name":"Range","range":"(0,10 – 20) mg/l"}],"search_en":"Water, wastewater Mineral oil index Gas chromatography with flame ionization detection (GC-FID) Laboratory Range PN-EN ISO 9377-2:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Water, wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,10 – 20) mg/l"}],"search_zh":"水、废水 矿物油指数 气相色谱-氢火焰离子化检测法（GC-FID） 实验室 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"水、废水","methodology_zh":"矿物油指数"},{"_id":"6a7f073d5decf8eaf531b30d","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,013 – 10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,013 – 10) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotynowego\nZakres (0,013 – 10) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego\nZakres (0,013 – 10) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,013 – 10) mg/l"}],"search_en":"Water, wastewater Nitrite nitrogen concentration Spectrophotometric method Laboratory Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","lab_section_zh":"实验室","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,013 – 10) mg/l"}],"search_zh":"水、废水 亚硝态氮浓度 分光光度法 实验室 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a7f073d5decf8eaf531b30e","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,1 – 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,1 – 50) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,1 – 50) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,1 – 50) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,1 – 50) mg/l"}],"search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Laboratory Range PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","lab_section_zh":"实验室","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,1 – 50) mg/l"}],"search_zh":"水、废水 总磷浓度 分光光度法 实验室 范围 PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a7f073d5decf8eaf531b30f","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,1 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,1 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,1 – 100) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,1 – 100) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,1 – 100) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Spectrophotometric method Laboratory Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","lab_section_zh":"实验室","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,1 – 100) mg/l"}],"search_zh":"水、废水 氨氮浓度 分光光度法 实验室 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a7f073d5decf8eaf531b310","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Indeks fenolowy","parameters":[{"name":"Zakres","range":"(0,020 – 50,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Indeks fenolowy\nZakres (0,020 – 50,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994","norm_bases":["PN-ISO 6439:1994"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Indeks fenolowy\nZakres (0,020 – 50,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 Woda, scieki Indeks fenolowy\nZakres (0,020 – 50,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Phenol index","parameters_en":[{"name":"Range","range":"(0,020 – 50,0) mg/l"}],"search_en":"Water, wastewater Phenol index Spectrophotometric method Laboratory Range PN-ISO 6439:1994","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,020 – 50,0) mg/l"}],"search_zh":"水、废水 酚指数 分光光度法 实验室 范围 PN-ISO 6439:1994","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"酚指数"},{"_id":"6a7f073d5decf8eaf531b311","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(0,50 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(0,50 – 6,0) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand Electrochemical method Laboratory BOD5 Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","lab_section_zh":"实验室","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(0,50 – 6,0) mg/l O2"}],"search_zh":"水、废水 生化需氧量 电化学法 实验室 BZT5（BOD5） 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、废水"},{"_id":"6a7f073d5decf8eaf531b312","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(3 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(3 – 6000) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand Electrochemical method Laboratory BOD5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","lab_section_zh":"实验室","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(3 – 6000) mg/l O2"}],"search_zh":"水、废水 生化需氧量 电化学法 实验室 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、废水"},{"_id":"6a7f073d5decf8eaf531b313","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zasadowość ogólna","parameters":[{"name":"Zakres","range":"(0,4 – 10) mmol/l"},{"name":"Zakres","range":"(0,2 – 5) mmol/l CaCO3"},{"name":"Zakres","range":"(20 – 500) mg/l CaCO3"},{"name":"Zakres","range":"(1,12 – 28) °n"},{"name":"Zakres","range":"(24,4 – 610) mg/l HCO3-"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zasadowość ogólna\nZakres:\nZakres (0,4 – 10) mmol/l\nZakres (0,2 – 5) mmol/l CaCO3\nZakres (20 – 500) mg/l CaCO3\nZakres (1,12 – 28) °n\nZakres (24,4 – 610) mg/l HCO3-\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zasadowość ogólna\nZakres:\nZakres (0,4 – 10) mmol/l\nZakres (0,2 – 5) mmol/l CaCO3\nZakres (20 – 500) mg/l CaCO3\nZakres (1,12 – 28) °n\nZakres (24,4 – 610) mg/l HCO3-\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004 Woda, scieki Zasadowosc ogolna\nZakres:\nZakres (0,4 – 10) mmol/l\nZakres (0,2 – 5) mmol/l CaCO3\nZakres (20 – 500) mg/l CaCO3\nZakres (1,12 – 28) °n\nZakres (24,4 – 610) mg/l HCO3-\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total alkalinity","parameters_en":[{"name":"Range","range":"(0,4 – 10) mmol/l"},{"name":"Range","range":"(0,2 – 5) mmol/l CaCO3"},{"name":"Range","range":"(20 – 500) mg/l CaCO3"},{"name":"Range","range":"(1,12 – 28) °n"},{"name":"Range","range":"(24,4 – 610) mg/l HCO3-"}],"search_en":"Water, wastewater Total alkalinity Titrimetric method Laboratory Range Range Range Range Range PN-EN ISO 9963-1:2001+Ap1:2004","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,4 – 10) mmol/l"},{"name":"范围","range":"(0,2 – 5) mmol/l CaCO3"},{"name":"范围","range":"(20 – 500) mg/l CaCO3"},{"name":"范围","range":"(1,12 – 28) °n"},{"name":"范围","range":"(24,4 – 610) mg/l HCO3-"}],"search_zh":"水、废水 总碱度 滴定法 实验室 范围 范围 范围 范围 范围 PN-EN ISO 9963-1:2001+Ap1:2004","technique_zh":"滴定法","test_object_zh":"水、废水","methodology_zh":"总碱度"},{"_id":"6a7f073d5decf8eaf531b314","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Substancje rozpuszczone","parameters":[{"name":"Zakres","range":"(100 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje rozpuszczone\nZakres (100 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Substancje rozpuszczone\nZakres (100 – 1000) mg/l\nMetoda wagowa PN-EN 15216:2022-03 Woda, scieki Substancje rozpuszczone\nZakres (100 – 1000) mg/l\nMetoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Dissolved solids","parameters_en":[{"name":"Range","range":"(100 – 1000) mg/l"}],"search_en":"Water, wastewater Dissolved solids Gravimetric method Laboratory Range PN-EN 15216:2022-03","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(100 – 1000) mg/l"}],"search_zh":"水、废水 溶解性固体 重量法 实验室 范围 PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"溶解性固体"},{"_id":"6a7f073d5decf8eaf531b315","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Sucha pozostałość","parameters":[{"name":"Zakres","range":"(100 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość\nZakres (100 – 2000) mg/l\nMetoda wagowa","reference":"PN-78/C-04541","norm_bases":["PN-78/C-04541"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Sucha pozostałość\nZakres (100 – 2000) mg/l\nMetoda wagowa PN-78/C-04541 Woda, scieki Sucha pozostalosc\nZakres (100 – 2000) mg/l\nMetoda wagowa PN-78/C-04541","categories":["water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Dry residue","parameters_en":[{"name":"Range","range":"(100 – 2000) mg/l"}],"search_en":"Water, wastewater Dry residue Gravimetric method Laboratory Range PN-78/C-04541","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(100 – 2000) mg/l"}],"search_zh":"水、废水 干残渣 重量法 实验室 范围 PN-78/C-04541","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"干残渣"},{"_id":"6a7f073d5decf8eaf531b316","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(1,0 – 500) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (1,0 – 500) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres (1,0 – 500) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla\nZakres (1,0 – 500) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,0 – 500) mg/l"}],"search_en":"Water, wastewater Kjeldahl nitrogen concentration Titrimetric method Laboratory Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","lab_section_zh":"实验室","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 500) mg/l"}],"search_zh":"水、废水 凯氏氮浓度 滴定法 实验室 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a7f073d5decf8eaf531b317","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB nr 05/2019 wydanie 1 z dnia 31.10.2019 r.","norm_bases":["PB nr 05/2019 wydanie 1 z dnia 31.10.2019 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu ogólnego (z obliczeń) PB nr 05/2019 wydanie 1 z dnia 31.10.2019 r. Woda, scieki Stezenie azotu ogolnego (z obliczen) PB nr 05/2019 wydanie 1 z dnia 31.10.2019 r.","categories":["water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water, wastewater Total nitrogen concentration (calculated) Laboratory PB nr 05/2019 wydanie 1 z dnia 31.10.2019 r.","test_object_en":"Water, wastewater","lab_section_zh":"实验室","methodology_zh":"总氮浓度（计算值）","search_zh":"水、废水 总氮浓度（计算值） 实验室 PB nr 05/2019 wydanie 1 z dnia 31.10.2019 r.","test_object_zh":"水、废水"},{"_id":"6a7f073d5decf8eaf531b318","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie surfaktantów anionowych (anionowych substancji powierzchniowo czynnych)","parameters":[{"name":"Zakres","range":"(0,10 – 80,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie surfaktantów anionowych (anionowych substancji powierzchniowo czynnych)\nZakres (0,10 – 80,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 903:2002","norm_bases":["PN-EN 903:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie surfaktantów anionowych (anionowych substancji powierzchniowo czynnych)\nZakres (0,10 – 80,0) mg/l\nMetoda spektrofotometryczna PN-EN 903:2002 Woda, scieki Stezenie surfaktantow anionowych (anionowych substancji powierzchniowo czynnych)\nZakres (0,10 – 80,0) mg/l\nMetoda spektrofotometryczna PN-EN 903:2002","categories":["water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","parameters_en":[{"name":"Range","range":"(0,10 – 80,0) mg/l"}],"search_en":"Water, wastewater Spectrophotometric method Laboratory Range PN-EN 903:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,10 – 80,0) mg/l"}],"search_zh":"水、废水 分光光度法 实验室 范围 PN-EN 903:2002","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a7f073d5decf8eaf531b319","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"1,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 1,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki pH\nZakres 1,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, woda do spozycia przez ludzi, scieki pH\nZakres 1,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"1,0 – 12,0"}],"search_en":"Water, water intended for human consumption, wastewater pH Potentiometric method Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, water intended for human consumption, wastewater","lab_section_zh":"实验室","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"1,0 – 12,0"}],"search_zh":"水、生活饮用水、污水 pH 值 电位法 实验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a7f073d5decf8eaf531b31a","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(100 – 13000) µS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (100 – 13000) µS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Przewodność elektryczna właściwa\nZakres (100 – 13000) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, woda do spozycia przez ludzi, scieki Przewodnosc elektryczna wlasciwa\nZakres (100 – 13000) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(100 – 13000) µS/cm"}],"search_en":"Water, water intended for human consumption, wastewater Electrical conductivity Conductometric method Laboratory Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, water intended for human consumption, wastewater","lab_section_zh":"实验室","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(100 – 13000) µS/cm"}],"search_zh":"水、生活饮用水、污水 电导率 电导法 实验室 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a7f073d5decf8eaf531b31b","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie indeksu nadmanganianowego","parameters":[{"name":"Zakres","range":"(0,5 – 10) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie indeksu nadmanganianowego\nZakres (0,5 – 10) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie indeksu nadmanganianowego\nZakres (0,5 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, woda do spozycia przez ludzi, scieki Stezenie indeksu nadmanganianowego\nZakres (0,5 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","parameters_en":[{"name":"Range","range":"(0,5 – 10) mg/l O2"}],"search_en":"Water, water intended for human consumption, wastewater Titrimetric method Laboratory Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption, wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,5 – 10) mg/l O2"}],"search_zh":"水、生活饮用水、污水 滴定法 实验室 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a7f073d5decf8eaf531b31c","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie fluorków","parameters":[{"name":"Zakres","range":"(0,05 – 100) mg/l"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Stężenie fluorków\nZakres (0,05 – 100) mg/l\nMetoda potencjometryczna","reference":"PN-78/C-04588/03","norm_bases":["PN-78/C-04588/03"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie fluorków\nZakres (0,05 – 100) mg/l\nMetoda potencjometryczna PN-78/C-04588/03 Woda, woda do spozycia przez ludzi, scieki Stezenie fluorkow\nZakres (0,05 – 100) mg/l\nMetoda potencjometryczna PN-78/C-04588/03","categories":["water"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Fluoride concentration","parameters_en":[{"name":"Range","range":"(0,05 – 100) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Fluoride concentration Potentiometric method Laboratory Range PN-78/C-04588/03","technique_en":"Potentiometric method","test_object_en":"Water, water intended for human consumption, wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,05 – 100) mg/l"}],"search_zh":"水、生活饮用水、污水 氟化物浓度 电位法 实验室 范围 PN-78/C-04588/03","technique_zh":"电位法","test_object_zh":"水、生活饮用水、污水","methodology_zh":"氟化物浓度"},{"_id":"6a7f073d5decf8eaf531b31d","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10 – 1000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie siarczanów\nZakres (10 – 1000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, woda do spozycia przez ludzi, scieki Stezenie siarczanow\nZakres (10 – 1000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10 – 1000) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Sulfate concentration Gravimetric method Laboratory Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Water, water intended for human consumption, wastewater","lab_section_zh":"实验室","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 – 1000) mg/l"}],"search_zh":"水、生活饮用水、污水 硫酸盐浓度 重量法 实验室 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a7f073d5decf8eaf531b31e","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,0002 – 1,0) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z amalgamacją","techniques":["Metoda absorpcyjnej spektrometrii atomowej z amalgamacją"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,0002 – 1,0) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z amalgamacją","reference":"PN-EN ISO 12846:2012 + Ap1:2016-07","norm_bases":["PN-EN ISO 12846:2012 + Ap1:2016-07"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie rtęci\nZakres (0,0002 – 1,0) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z amalgamacją PN-EN ISO 12846:2012 + Ap1:2016-07 Woda, woda do spozycia przez ludzi, scieki Stezenie rteci\nZakres (0,0002 – 1,0) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z amalgamacja PN-EN ISO 12846:2012 + Ap1:2016-07","categories":["water"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,0002 – 1,0) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Mercury concentration Atomic absorption spectrometry with amalgamation Laboratory Range PN-EN ISO 12846:2012 + Ap1:2016-07","technique_en":"Atomic absorption spectrometry with amalgamation","test_object_en":"Water, water intended for human consumption, wastewater","lab_section_zh":"实验室","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,0002 – 1,0) mg/l"}],"search_zh":"水、生活饮用水、污水 汞浓度 实验室 范围 PN-EN ISO 12846:2012 + Ap1:2016-07","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a7f073d5decf8eaf531b31f","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie surfaktantów anionowych (anionowych substancji powierzchniowo czynnych)","parameters":[{"name":"Zakres","range":"(0,050 – 80,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie surfaktantów anionowych (anionowych substancji powierzchniowo czynnych)\nZakres (0,050 – 80,0) mg/l\nMetoda spektrofotometryczna","reference":"PB nr 02/2020 wydanie 1 z dnia 30.10.2020 r. | na podstawie testu kuwetowego Hach nr LCK 332, 432","norm_bases":["PB nr 02/2020 wydanie 1 z dnia 30.10.2020 r.","na podstawie testu kuwetowego Hach nr LCK 332, 432"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie surfaktantów anionowych (anionowych substancji powierzchniowo czynnych)\nZakres (0,050 – 80,0) mg/l\nMetoda spektrofotometryczna PB nr 02/2020 wydanie 1 z dnia 30.10.2020 r. | na podstawie testu kuwetowego Hach nr LCK 332, 432 Woda, woda do spozycia przez ludzi, scieki Stezenie surfaktantow anionowych (anionowych substancji powierzchniowo czynnych)\nZakres (0,050 – 80,0) mg/l\nMetoda spektrofotometryczna PB nr 02/2020 wydanie 1 z dnia 30.10.2020 r. | na podstawie testu kuwetowego Hach nr LCK 332, 432","categories":["water"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","parameters_en":[{"name":"Range","range":"(0,050 – 80,0) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Spectrophotometric method Laboratory Range PB nr 02/2020 wydanie 1 z dnia 30.10.2020 r. | na podstawie testu kuwetowego Hach nr LCK 332, 432","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,050 – 80,0) mg/l"}],"search_zh":"水、生活饮用水、污水 分光光度法 实验室 范围 PB nr 02/2020 wydanie 1 z dnia 30.10.2020 r. | na podstawie testu kuwetowego Hach nr LCK 332, 432","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a7f073d5decf8eaf531b320","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie magnezu","parameters":[{"name":"Zakres","range":"(0,10 – 50) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie magnezu\nZakres (0,10 – 50) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN ISO 7980:2002","norm_bases":["PN-EN ISO 7980:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie magnezu\nZakres (0,10 – 50) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980:2002 Woda, woda do spozycia przez ludzi, scieki Stezenie magnezu\nZakres (0,10 – 50) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980:2002","categories":["water"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Magnesium concentration","parameters_en":[{"name":"Range","range":"(0,10 – 50) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Magnesium concentration Flame atomic absorption spectrometry (FAAS) Laboratory Range PN-EN ISO 7980:2002","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water, water intended for human consumption, wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,10 – 50) mg/l"}],"search_zh":"水、生活饮用水、污水 镁浓度 火焰原子吸收光谱法（FAAS） 实验室 范围 PN-EN ISO 7980:2002","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、生活饮用水、污水","methodology_zh":"镁浓度"},{"_id":"6a7f073d5decf8eaf531b321","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie wapnia","parameters":[{"name":"Zakres","range":"(0,50 – 200) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie wapnia\nZakres (0,50 – 200) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN ISO 7980:2002","norm_bases":["PN-EN ISO 7980:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie wapnia\nZakres (0,50 – 200) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980:2002 Woda, woda do spozycia przez ludzi, scieki Stezenie wapnia\nZakres (0,50 – 200) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980:2002","categories":["water"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Calcium concentration","parameters_en":[{"name":"Range","range":"(0,50 – 200) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Calcium concentration Flame atomic absorption spectrometry (FAAS) Laboratory Range PN-EN ISO 7980:2002","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water, water intended for human consumption, wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,50 – 200) mg/l"}],"search_zh":"水、生活饮用水、污水 钙浓度 火焰原子吸收光谱法（FAAS） 实验室 范围 PN-EN ISO 7980:2002","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、生活饮用水、污水","methodology_zh":"钙浓度"},{"_id":"6a7f073d5decf8eaf531b322","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Osady ściekowe, odpady o): kod 19 08 05","methodology":"Pobieranie próbek osadów do badań chemicznych, fizycznych, mikrobiologicznych i parazytologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek osadów do badań chemicznych, fizycznych, mikrobiologicznych i parazytologicznych","reference":"PN-EN ISO 5667-13:2011","norm_bases":["PN-EN ISO 5667-13:2011"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe, odpady o): kod 19 08 05 Pobieranie próbek osadów do badań chemicznych, fizycznych, mikrobiologicznych i parazytologicznych PN-EN ISO 5667-13:2011 Osady sciekowe, odpady o): kod 19 08 05 Pobieranie probek osadow do badan chemicznych, fizycznych, mikrobiologicznych i parazytologicznych PN-EN ISO 5667-13:2011","categories":["water","environment","microbiology"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sludge sampling for chemical, physical, microbiological and parasitological testing","search_en":"Sewage sludge, waste o): code 19 08 05 Sludge sampling for chemical, physical, microbiological and parasitological testing Laboratory PN-EN ISO 5667-13:2011","test_object_en":"Sewage sludge, waste o): code 19 08 05","lab_section_zh":"实验室","search_zh":"污水污泥、废物 o)：代码 19 08 05 实验室 PN-EN ISO 5667-13:2011","test_object_zh":"污水污泥、废物 o)：代码 19 08 05"},{"_id":"6a7f073d5decf8eaf531b323","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Osady ściekowe, odpady o): kod 19 08 05","methodology":"Zawartość metali","parameters":[{"name":"Chrom","range":"(4,0 – 2500) mg/kg"},{"name":"Miedź","range":"(2,0 – 2000) mg/kg"},{"name":"Nikiel","range":"(3,0 – 500) mg/kg"},{"name":"Kadm","range":"(2,0 – 250) mg/kg"},{"name":"Ołów","range":"(6,0 – 1500) mg/kg"},{"name":"Cynk","range":"(5,0 – 5000) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość metali\nZakres:\nChrom (4,0 – 2500) mg/kg\nMiedź (2,0 – 2000) mg/kg\nNikiel (3,0 – 500) mg/kg\nKadm (2,0 – 250) mg/kg\nOłów (6,0 – 1500) mg/kg\nCynk (5,0 – 5000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN ISO 8288:2002 | PN-EN ISO 54321:2021-07","norm_bases":["PN ISO 8288:2002","PN-EN ISO 54321:2021-07"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe, odpady o): kod 19 08 05 Zawartość metali\nZakres:\nChrom (4,0 – 2500) mg/kg\nMiedź (2,0 – 2000) mg/kg\nNikiel (3,0 – 500) mg/kg\nKadm (2,0 – 250) mg/kg\nOłów (6,0 – 1500) mg/kg\nCynk (5,0 – 5000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN ISO 8288:2002 | PN-EN ISO 54321:2021-07 Osady sciekowe, odpady o): kod 19 08 05 Zawartosc metali\nZakres:\nChrom (4,0 – 2500) mg/kg\nMiedz (2,0 – 2000) mg/kg\nNikiel (3,0 – 500) mg/kg\nKadm (2,0 – 250) mg/kg\nOlow (6,0 – 1500) mg/kg\nCynk (5,0 – 5000) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN ISO 8288:2002 | PN-EN ISO 54321:2021-07","categories":["materials","water","environment"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Metal content","parameters_en":[{"name":"Chromium","range":"(4,0 – 2500) mg/kg"},{"name":"Copper","range":"(2,0 – 2000) mg/kg"},{"name":"Nickel","range":"(3,0 – 500) mg/kg"},{"name":"Cadmium","range":"(2,0 – 250) mg/kg"},{"name":"Lead","range":"(6,0 – 1500) mg/kg"},{"name":"Zinc","range":"(5,0 – 5000) mg/kg"}],"search_en":"Sewage sludge, waste o): code 19 08 05 Metal content Flame atomic absorption spectrometry (FAAS) Laboratory Chromium Copper Nickel Cadmium Lead Zinc PN ISO 8288:2002 | PN-EN ISO 54321:2021-07","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Sewage sludge, waste o): code 19 08 05","lab_section_zh":"实验室","parameters_zh":[{"name":"铬","range":"(4,0 – 2500) mg/kg"},{"name":"铜","range":"(2,0 – 2000) mg/kg"},{"name":"镍","range":"(3,0 – 500) mg/kg"},{"name":"镉","range":"(2,0 – 250) mg/kg"},{"name":"铅","range":"(6,0 – 1500) mg/kg"},{"name":"锌","range":"(5,0 – 5000) mg/kg"}],"search_zh":"污水污泥、废物 o)：代码 19 08 05 金属含量 火焰原子吸收光谱法（FAAS） 实验室 铬 铜 镍 镉 铅 锌 PN ISO 8288:2002 | PN-EN ISO 54321:2021-07","technique_zh":"火焰原子吸收光谱法（FAAS）","methodology_zh":"金属含量","test_object_zh":"污水污泥、废物 o)：代码 19 08 05"},{"_id":"6a7f073d5decf8eaf531b324","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Osady ściekowe, odpady o): kod 19 08 05","methodology":"Zawartość metali","parameters":[{"name":"Wapń","range":"(8000 – 200000) mg/kg"},{"name":"Magnez","range":"(500 – 40000) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość metali\nZakres:\nWapń (8000 – 200000) mg/kg\nMagnez (500 – 40000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN ISO 7980:2002 | PN-EN ISO 54321:2021-07","norm_bases":["PN-EN ISO 7980:2002","PN-EN ISO 54321:2021-07"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe, odpady o): kod 19 08 05 Zawartość metali\nZakres:\nWapń (8000 – 200000) mg/kg\nMagnez (500 – 40000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980:2002 | PN-EN ISO 54321:2021-07 Osady sciekowe, odpady o): kod 19 08 05 Zawartosc metali\nZakres:\nWapn (8000 – 200000) mg/kg\nMagnez (500 – 40000) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980:2002 | PN-EN ISO 54321:2021-07","categories":["water","materials","environment"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Metal content","parameters_en":[{"name":"Calcium","range":"(8000 – 200000) mg/kg"},{"name":"Magnesium","range":"(500 – 40000) mg/kg"}],"search_en":"Sewage sludge, waste o): code 19 08 05 Metal content Flame atomic absorption spectrometry (FAAS) Laboratory Calcium Magnesium PN-EN ISO 7980:2002 | PN-EN ISO 54321:2021-07","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Sewage sludge, waste o): code 19 08 05","lab_section_zh":"实验室","search_zh":"污水污泥、废物 o)：代码 19 08 05 金属含量 火焰原子吸收光谱法（FAAS） 实验室 钙 镁 PN-EN ISO 7980:2002 | PN-EN ISO 54321:2021-07","technique_zh":"火焰原子吸收光谱法（FAAS）","methodology_zh":"金属含量","parameters_zh":[{"name":"钙","range":"(8000 – 200000) mg/kg"},{"name":"镁","range":"(500 – 40000) mg/kg"}],"test_object_zh":"污水污泥、废物 o)：代码 19 08 05"},{"_id":"6a7f073d5decf8eaf531b325","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Osady ściekowe, odpady o): kod 19 08 05","methodology":"Zawartość suchej pozostałości/ Zawartość wody","parameters":[{"name":"Zakres","range":"(1,0 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość suchej pozostałości/ Zawartość wody\nZakres (1,0 – 99,0) %\nMetoda wagowa","reference":"PN-EN 12880:2004","norm_bases":["PN-EN 12880:2004"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe, odpady o): kod 19 08 05 Zawartość suchej pozostałości/ Zawartość wody\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 12880:2004 Osady sciekowe, odpady o): kod 19 08 05 Zawartosc suchej pozostalosci/ Zawartosc wody\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 12880:2004","categories":["water","environment"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","parameters_en":[{"name":"Range","range":"(1,0 – 99,0) %"}],"search_en":"Sewage sludge, waste o): code 19 08 05 Gravimetric method Laboratory Range PN-EN 12880:2004","technique_en":"Gravimetric method","test_object_en":"Sewage sludge, waste o): code 19 08 05","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(1,0 – 99,0) %"}],"search_zh":"污水污泥、废物 o)：代码 19 08 05 重量法 实验室 范围 PN-EN 12880:2004","technique_zh":"重量法","test_object_zh":"污水污泥、废物 o)：代码 19 08 05"},{"_id":"6a7f073d5decf8eaf531b326","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Osady ściekowe, odpady o): kod 19 08 05","methodology":"Straty przy prażeniu/ Pozostałość przy prażeniu","parameters":[{"name":"Zakres","range":"(1,0 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu/ Pozostałość przy prażeniu\nZakres (1,0 – 99,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe, odpady o): kod 19 08 05 Straty przy prażeniu/ Pozostałość przy prażeniu\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15935:2022-01 Osady sciekowe, odpady o): kod 19 08 05 Straty przy prazeniu/ Pozostalosc przy prazeniu\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["water","environment"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","parameters_en":[{"name":"Range","range":"(1,0 – 99,0) %"}],"search_en":"Sewage sludge, waste o): code 19 08 05 Gravimetric method Laboratory Range PN-EN 15935:2022-01","technique_en":"Gravimetric method","test_object_en":"Sewage sludge, waste o): code 19 08 05","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(1,0 – 99,0) %"}],"search_zh":"污水污泥、废物 o)：代码 19 08 05 重量法 实验室 范围 PN-EN 15935:2022-01","technique_zh":"重量法","test_object_zh":"污水污泥、废物 o)：代码 19 08 05"},{"_id":"6a7f073d5decf8eaf531b327","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Osady ściekowe, odpady o): kod 19 08 05","methodology":"pH - w H2O","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH - w H2O\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN 10390:2022-09","norm_bases":["PN-EN 10390:2022-09"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe, odpady o): kod 19 08 05 pH - w H2O\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN 10390:2022-09 Osady sciekowe, odpady o): kod 19 08 05 pH - w H2O\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN 10390:2022-09","categories":["water","environment"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"pH - in H2O","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Sewage sludge, waste o): code 19 08 05 pH - in H2O Potentiometric method Laboratory Range PN-EN 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Sewage sludge, waste o): code 19 08 05","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"污水污泥、废物 o)：代码 19 08 05 pH - 于 H2O 中 电位法 实验室 范围 PN-EN 10390:2022-09","technique_zh":"电位法","methodology_zh":"pH - 于 H2O 中","test_object_zh":"污水污泥、废物 o)：代码 19 08 05"},{"_id":"6a7f073d5decf8eaf531b328","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Osady ściekowe, odpady o): kod 19 08 05","methodology":"Zawartość fosforu ogólnego","parameters":[{"name":"Zakres","range":"(1,00 – 10,0) %"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu ogólnego\nZakres (1,00 – 10,0) %\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 | PN-EN ISO 54321:2021-07","norm_bases":["PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","PN-EN ISO 54321:2021-07"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe, odpady o): kod 19 08 05 Zawartość fosforu ogólnego\nZakres (1,00 – 10,0) %\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 | PN-EN ISO 54321:2021-07 Osady sciekowe, odpady o): kod 19 08 05 Zawartosc fosforu ogolnego\nZakres (1,00 – 10,0) %\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 | PN-EN ISO 54321:2021-07","categories":["water","environment"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total phosphorus content","parameters_en":[{"name":"Range","range":"(1,00 – 10,0) %"}],"search_en":"Sewage sludge, waste o): code 19 08 05 Total phosphorus content Spectrophotometric method Laboratory Range PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 | PN-EN ISO 54321:2021-07","technique_en":"Spectrophotometric method","test_object_en":"Sewage sludge, waste o): code 19 08 05","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(1,00 – 10,0) %"}],"search_zh":"污水污泥、废物 o)：代码 19 08 05 总磷含量 分光光度法 实验室 范围 PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 | PN-EN ISO 54321:2021-07","technique_zh":"分光光度法","methodology_zh":"总磷含量","test_object_zh":"污水污泥、废物 o)：代码 19 08 05"},{"_id":"6a7f073d5decf8eaf531b329","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,10 – 10,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu Kjeldahla\nZakres (0,10 – 10,0) %\nMetoda miareczkowa","reference":"PN-EN 13342:2002","norm_bases":["PN-EN 13342:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość azotu Kjeldahla\nZakres (0,10 – 10,0) %\nMetoda miareczkowa PN-EN 13342:2002 Osady sciekowe Zawartosc azotu Kjeldahla\nZakres (0,10 – 10,0) %\nMetoda miareczkowa PN-EN 13342:2002","categories":["water"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Kjeldahl nitrogen content","parameters_en":[{"name":"Range","range":"(0,10 – 10,0) %"}],"search_en":"Sewage sludge Kjeldahl nitrogen content Titrimetric method Laboratory Range PN-EN 13342:2002","technique_en":"Titrimetric method","test_object_en":"Sewage sludge","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,10 – 10,0) %"}],"search_zh":"污泥 凯氏氮含量 滴定法 实验室 范围 PN-EN 13342:2002","technique_zh":"滴定法","test_object_zh":"污泥","methodology_zh":"凯氏氮含量"},{"_id":"6a7f073d5decf8eaf531b32a","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,05 – 20,0) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,05 – 20,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PN-EN ISO 12846:2012 + Ap1:2016-07 | PN-EN ISO 54321:2021-07","norm_bases":["PN-EN ISO 12846:2012 + Ap1:2016-07","PN-EN ISO 54321:2021-07"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość rtęci\nZakres (0,05 – 20,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PN-EN ISO 12846:2012 + Ap1:2016-07 | PN-EN ISO 54321:2021-07 Osady sciekowe Zawartosc rteci\nZakres (0,05 – 20,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PN-EN ISO 12846:2012 + Ap1:2016-07 | PN-EN ISO 54321:2021-07","categories":["water"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,05 – 20,0) mg/kg"}],"search_en":"Sewage sludge Mercury content Atomic absorption spectrometry with amalgamation technique Laboratory Range PN-EN ISO 12846:2012 + Ap1:2016-07 | PN-EN ISO 54321:2021-07","technique_en":"Atomic absorption spectrometry with amalgamation technique","test_object_en":"Sewage sludge","lab_section_zh":"实验室","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,05 – 20,0) mg/kg"}],"search_zh":"污泥 汞含量 原子吸收光谱法（汞齐化技术） 实验室 范围 PN-EN ISO 12846:2012 + Ap1:2016-07 | PN-EN ISO 54321:2021-07","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"污泥"},{"_id":"6a7f073d5decf8eaf531b32b","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość azotu amonowego","parameters":[{"name":"Zakres","range":"(0,010 – 5,00) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu amonowego\nZakres (0,010 – 5,00) %\nMetoda miareczkowa","reference":"PN-EN 14671:2007 | PN-ISO 5664:2002","norm_bases":["PN-EN 14671:2007","PN-ISO 5664:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość azotu amonowego\nZakres (0,010 – 5,00) %\nMetoda miareczkowa PN-EN 14671:2007 | PN-ISO 5664:2002 Osady sciekowe Zawartosc azotu amonowego\nZakres (0,010 – 5,00) %\nMetoda miareczkowa PN-EN 14671:2007 | PN-ISO 5664:2002","categories":["water"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Ammonium nitrogen content","parameters_en":[{"name":"Range","range":"(0,010 – 5,00) %"}],"search_en":"Sewage sludge Ammonium nitrogen content Titrimetric method Laboratory Range PN-EN 14671:2007 | PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Sewage sludge","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,010 – 5,00) %"}],"search_zh":"污泥 氨氮含量 滴定法 实验室 范围 PN-EN 14671:2007 | PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"污泥","methodology_zh":"氨氮含量"},{"_id":"6a7f073d5decf8eaf531b32c","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Gleba mineralna","methodology":"Zawartość przyswajalnego fosforu","parameters":[{"name":"Zakres","range":"(1 – 50) mg P2O5/100g"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość przyswajalnego fosforu\nZakres (1 – 50) mg P2O5/100g\nMetoda spektrofotometryczna","reference":"PN-R-04023:1996","norm_bases":["PN-R-04023:1996"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba mineralna Zawartość przyswajalnego fosforu\nZakres (1 – 50) mg P2O5/100g\nMetoda spektrofotometryczna PN-R-04023:1996 Gleba mineralna Zawartosc przyswajalnego fosforu\nZakres (1 – 50) mg P2O5/100g\nMetoda spektrofotometryczna PN-R-04023:1996","categories":["environment"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Available phosphorus content","parameters_en":[{"name":"Range","range":"(1 – 50) mg P2O5/100g"}],"search_en":"Mineral soil Available phosphorus content Spectrophotometric method Laboratory Range PN-R-04023:1996","technique_en":"Spectrophotometric method","test_object_en":"Mineral soil","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(1 – 50) mg P2O5/100g"}],"search_zh":"矿质土壤 有效磷含量 分光光度法 实验室 范围 PN-R-04023:1996","technique_zh":"分光光度法","test_object_zh":"矿质土壤","methodology_zh":"有效磷含量"},{"_id":"6a7f073d5decf8eaf531b32d","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Gleba organiczna","methodology":"Zawartość przyswajalnego fosforu","parameters":[{"name":"Zakres","range":"(12,5 – 250) mg P2O5/100g"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość przyswajalnego fosforu\nZakres (12,5 – 250) mg P2O5/100g\nMetoda spektrofotometryczna","reference":"PN-R-04024:1997","norm_bases":["PN-R-04024:1997"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba organiczna Zawartość przyswajalnego fosforu\nZakres (12,5 – 250) mg P2O5/100g\nMetoda spektrofotometryczna PN-R-04024:1997 Gleba organiczna Zawartosc przyswajalnego fosforu\nZakres (12,5 – 250) mg P2O5/100g\nMetoda spektrofotometryczna PN-R-04024:1997","categories":["environment"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Available phosphorus content","parameters_en":[{"name":"Range","range":"(12,5 – 250) mg P2O5/100g"}],"search_en":"Organic soil Available phosphorus content Spectrophotometric method Laboratory Range PN-R-04024:1997","technique_en":"Spectrophotometric method","test_object_en":"Organic soil","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(12,5 – 250) mg P2O5/100g"}],"search_zh":"有机土壤 有效磷含量 分光光度法 实验室 范围 PN-R-04024:1997","technique_zh":"分光光度法","methodology_zh":"有效磷含量","test_object_zh":"有机土壤"},{"_id":"6a7f073d5decf8eaf531b32e","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Gleba","methodology":"pH - w H2O","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH - w H2O\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN 10390:2022-09","norm_bases":["PN-EN 10390:2022-09"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba pH - w H2O\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN 10390:2022-09 Gleba pH - w H2O\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN 10390:2022-09","categories":["environment"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"pH - in H2O","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Soil pH - in H2O Potentiometric method Laboratory Range PN-EN 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Soil","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"土壤 pH - 于 H2O 中 电位法 实验室 范围 PN-EN 10390:2022-09","technique_zh":"电位法","test_object_zh":"土壤","methodology_zh":"pH - 于 H2O 中"},{"_id":"6a7f073d5decf8eaf531b32f","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość suchej masy / wody","parameters":[{"name":"Zakres","range":"(1,0 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość suchej masy / wody\nZakres (1,0 – 99,0) %\nMetoda wagowa","reference":"PN-ISO 11465:1999","norm_bases":["PN-ISO 11465:1999"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość suchej masy / wody\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-ISO 11465:1999 Gleba Zawartosc suchej masy / wody\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-ISO 11465:1999","categories":["water","environment"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Dry matter / water content","parameters_en":[{"name":"Range","range":"(1,0 – 99,0) %"}],"search_en":"Soil Dry matter / water content Gravimetric method Laboratory Range PN-ISO 11465:1999","technique_en":"Gravimetric method","test_object_en":"Soil","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(1,0 – 99,0) %"}],"search_zh":"土壤 重量法 实验室 范围 PN-ISO 11465:1999","technique_zh":"重量法","test_object_zh":"土壤"},{"_id":"6a7f073d5decf8eaf531b330","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość metali","parameters":[{"name":"Kadm","range":"(1,0 – 150) mg/kg"},{"name":"Ołów","range":"(5,0 – 500) mg/kg"},{"name":"Cynk","range":"(5,0 – 1500) mg/kg"},{"name":"Chrom","range":"(5,0 – 1000) mg/kg"},{"name":"Nikiel","range":"(5,0 – 500) mg/kg"},{"name":"Miedź","range":"(3,0 – 1000) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość metali\nZakres:\nKadm (1,0 – 150) mg/kg\nOłów (5,0 – 500) mg/kg\nCynk (5,0 – 1500) mg/kg\nChrom (5,0 – 1000) mg/kg\nNikiel (5,0 – 500) mg/kg\nMiedź (3,0 – 1000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 11047:2001 | PN-ISO 11466:2002","norm_bases":["PN-ISO 11047:2001","PN-ISO 11466:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość metali\nZakres:\nKadm (1,0 – 150) mg/kg\nOłów (5,0 – 500) mg/kg\nCynk (5,0 – 1500) mg/kg\nChrom (5,0 – 1000) mg/kg\nNikiel (5,0 – 500) mg/kg\nMiedź (3,0 – 1000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 11047:2001 | PN-ISO 11466:2002 Gleba Zawartosc metali\nZakres:\nKadm (1,0 – 150) mg/kg\nOlow (5,0 – 500) mg/kg\nCynk (5,0 – 1500) mg/kg\nChrom (5,0 – 1000) mg/kg\nNikiel (5,0 – 500) mg/kg\nMiedz (3,0 – 1000) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 11047:2001 | PN-ISO 11466:2002","categories":["materials","environment"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Metal content","parameters_en":[{"name":"Cadmium","range":"(1,0 – 150) mg/kg"},{"name":"Lead","range":"(5,0 – 500) mg/kg"},{"name":"Zinc","range":"(5,0 – 1500) mg/kg"},{"name":"Chromium","range":"(5,0 – 1000) mg/kg"},{"name":"Nickel","range":"(5,0 – 500) mg/kg"},{"name":"Copper","range":"(3,0 – 1000) mg/kg"}],"search_en":"Soil Metal content Flame atomic absorption spectrometry (FAAS) Laboratory Cadmium Lead Zinc Chromium Nickel Copper PN-ISO 11047:2001 | PN-ISO 11466:2002","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Soil","lab_section_zh":"实验室","parameters_zh":[{"name":"镉","range":"(1,0 – 150) mg/kg"},{"name":"铅","range":"(5,0 – 500) mg/kg"},{"name":"锌","range":"(5,0 – 1500) mg/kg"},{"name":"铬","range":"(5,0 – 1000) mg/kg"},{"name":"镍","range":"(5,0 – 500) mg/kg"},{"name":"铜","range":"(3,0 – 1000) mg/kg"}],"search_zh":"土壤 金属含量 火焰原子吸收光谱法（FAAS） 实验室 镉 铅 锌 铬 镍 铜 PN-ISO 11047:2001 | PN-ISO 11466:2002","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"土壤","methodology_zh":"金属含量"},{"_id":"6a7f073d5decf8eaf531b331","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,00050 – 1,00) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z amalgamacją","techniques":["Metoda absorpcyjnej spektrometrii atomowej z amalgamacją"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,00050 – 1,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z amalgamacją","reference":"PB nr 02/2021 wydanie 1 z dnia 12.05.2021 r.","norm_bases":["PB nr 02/2021 wydanie 1 z dnia 12.05.2021 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość rtęci\nZakres (0,00050 – 1,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z amalgamacją PB nr 02/2021 wydanie 1 z dnia 12.05.2021 r. Gleba Zawartosc rteci\nZakres (0,00050 – 1,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z amalgamacja PB nr 02/2021 wydanie 1 z dnia 12.05.2021 r.","categories":["environment"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,00050 – 1,00) mg/kg"}],"search_en":"Soil Mercury content Atomic absorption spectrometry with amalgamation Laboratory Range PB nr 02/2021 wydanie 1 z dnia 12.05.2021 r.","technique_en":"Atomic absorption spectrometry with amalgamation","test_object_en":"Soil","lab_section_zh":"实验室","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,00050 – 1,00) mg/kg"}],"search_zh":"土壤 汞含量 实验室 范围 PB nr 02/2021 wydanie 1 z dnia 12.05.2021 r.","test_object_zh":"土壤"},{"_id":"6a7f073d5decf8eaf531b332","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Gleba","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 10381-4:2007 | PN-R-04031:1997","norm_bases":["PN-ISO 10381-4:2007","PN-R-04031:1997"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 10381-4:2007 | PN-R-04031:1997 Gleba Pobieranie probek do badan chemicznych i fizycznych PN-ISO 10381-4:2007 | PN-R-04031:1997","categories":["environment"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Soil Sampling for chemical and physical testing Laboratory PN-ISO 10381-4:2007 | PN-R-04031:1997","test_object_en":"Soil","lab_section_zh":"实验室","methodology_zh":"化学与物理检测用样品采集","search_zh":"土壤 化学与物理检测用样品采集 实验室 PN-ISO 10381-4:2007 | PN-R-04031:1997","test_object_zh":"土壤"},{"_id":"6a7f073d5decf8eaf531b333","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Water intended for human consumption Sampling for chemical and physical testing Laboratory PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 实验室 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a7f073d5decf8eaf531b334","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(1,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (1,0 – 50,0) °C","reference":"PB nr 02/2008 wydanie 1 z dnia 15.09.2008 r.","norm_bases":["PB nr 02/2008 wydanie 1 z dnia 15.09.2008 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Temperatura\nZakres (1,0 – 50,0) °C PB nr 02/2008 wydanie 1 z dnia 15.09.2008 r. Woda do spozycia przez ludzi Temperatura\nZakres (1,0 – 50,0) °C PB nr 02/2008 wydanie 1 z dnia 15.09.2008 r.","categories":["water"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(1,0 – 50,0) °C"}],"search_en":"Water intended for human consumption Temperature Laboratory Range PB nr 02/2008 wydanie 1 z dnia 15.09.2008 r.","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(1,0 – 50,0) °C"}],"search_zh":"生活饮用水 温度 实验室 范围 PB nr 02/2008 wydanie 1 z dnia 15.09.2008 r.","test_object_zh":"生活饮用水","methodology_zh":"温度"},{"_id":"6a7f073d5decf8eaf531b335","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for microbiological testing","search_en":"Water intended for human consumption Sampling for microbiological testing Laboratory PN-EN ISO 19458:2007","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 实验室 PN-EN ISO 19458:2007","test_object_zh":"生活饮用水"},{"_id":"6a7f073d5decf8eaf531b336","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie miedzi","parameters":[{"name":"Zakres","range":"(0,050 – 6) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie miedzi\nZakres (0,050 – 6) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB nr 23/2010 wydanie 1 z dnia 11.02.2010 r.","norm_bases":["PB nr 23/2010 wydanie 1 z dnia 11.02.2010 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie miedzi\nZakres (0,050 – 6) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB nr 23/2010 wydanie 1 z dnia 11.02.2010 r. Woda do spozycia przez ludzi Stezenie miedzi\nZakres (0,050 – 6) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB nr 23/2010 wydanie 1 z dnia 11.02.2010 r.","categories":["water"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Copper concentration","parameters_en":[{"name":"Range","range":"(0,050 – 6) mg/l"}],"search_en":"Water intended for human consumption Copper concentration Flame atomic absorption spectrometry (FAAS) Laboratory Range PB nr 23/2010 wydanie 1 z dnia 11.02.2010 r.","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,050 – 6) mg/l"}],"search_zh":"生活饮用水 铜浓度 火焰原子吸收光谱法（FAAS） 实验室 范围 PB nr 23/2010 wydanie 1 z dnia 11.02.2010 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"生活饮用水","methodology_zh":"铜浓度"},{"_id":"6a7f073d5decf8eaf531b337","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda powierzchniowa","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-6:2016-12","norm_bases":["PN-EN ISO 5667-6:2016-12"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda powierzchniowa Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 Woda powierzchniowa Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-6:2016-12","categories":["water"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Surface water Sampling for chemical and physical testing Laboratory PN-EN ISO 5667-6:2016-12","test_object_en":"Surface water","lab_section_zh":"实验室","methodology_zh":"化学与物理检测用样品采集","search_zh":"地表水 化学与物理检测用样品采集 实验室 PN-EN ISO 5667-6:2016-12","test_object_zh":"地表水"},{"_id":"6a7f073d5decf8eaf531b338","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda powierzchniowa","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(1,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (1,0 – 50,0) °C","reference":"PB nr 02/2008 wydanie 1 z dnia 15.09.2008 r.","norm_bases":["PB nr 02/2008 wydanie 1 z dnia 15.09.2008 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda powierzchniowa Temperatura\nZakres (1,0 – 50,0) °C PB nr 02/2008 wydanie 1 z dnia 15.09.2008 r. Woda powierzchniowa Temperatura\nZakres (1,0 – 50,0) °C PB nr 02/2008 wydanie 1 z dnia 15.09.2008 r.","categories":["water"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(1,0 – 50,0) °C"}],"search_en":"Surface water Temperature Laboratory Range PB nr 02/2008 wydanie 1 z dnia 15.09.2008 r.","test_object_en":"Surface water","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(1,0 – 50,0) °C"}],"search_zh":"地表水 温度 实验室 范围 PB nr 02/2008 wydanie 1 z dnia 15.09.2008 r.","methodology_zh":"温度","test_object_zh":"地表水"},{"_id":"6a7f073d5decf8eaf531b339","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda podziemna","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2, 5.3.2.2, 6.2, 6.3","norm_bases":["PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2, 5.3.2.2, 6.2, 6.3"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda podziemna Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2, 5.3.2.2, 6.2, 6.3 Woda podziemna Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-11:2017-10 z wylaczeniem pkt 5.2, 5.3.2.2, 6.2, 6.3","categories":["water"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Groundwater Sampling for chemical and physical testing Laboratory PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2, 5.3.2.2, 6.2, 6.3","test_object_en":"Groundwater","lab_section_zh":"实验室","methodology_zh":"化学与物理检测用样品采集","search_zh":"地下水 化学与物理检测用样品采集 实验室 PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2, 5.3.2.2, 6.2, 6.3","test_object_zh":"地下水"},{"_id":"6a7f073d5decf8eaf531b33a","lab_id":"69ad52a3de79e566650fb54c","country":"PL","accr_number":"AB 1044","accr_body":"PCA","test_object":"Woda podziemna","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(1,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (1,0 – 50,0) °C","reference":"PB nr 02/2008 wydanie 1 z dnia 15.09.2008 r.","norm_bases":["PB nr 02/2008 wydanie 1 z dnia 15.09.2008 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda podziemna Temperatura\nZakres (1,0 – 50,0) °C PB nr 02/2008 wydanie 1 z dnia 15.09.2008 r. Woda podziemna Temperatura\nZakres (1,0 – 50,0) °C PB nr 02/2008 wydanie 1 z dnia 15.09.2008 r.","categories":["water"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(1,0 – 50,0) °C"}],"search_en":"Groundwater Temperature Laboratory Range PB nr 02/2008 wydanie 1 z dnia 15.09.2008 r.","test_object_en":"Groundwater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(1,0 – 50,0) °C"}],"search_zh":"地下水 温度 实验室 范围 PB nr 02/2008 wydanie 1 z dnia 15.09.2008 r.","methodology_zh":"温度","test_object_zh":"地下水"}],"has_pdf":true}