{"lab":{"_id":"69ad52a3de79e566650fb544","accr_number":"AB 1040","country":"PL","accr_body":"PCA","address":"LABORATORIUM, ul. Budowlanych 7, 86-300 Grudziądz","categories":["petro","environment"],"city":"Grudziądz","imported_at":"2026-03-08T10:42:43.265Z","methods_count":25,"name":"OPEC GRUDZIĄDZ Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1040.pdf"],"scope_summary":"","search_text":"opec grudziądz sp. z o.o. laboratorium, ul. budowlanych 7, 86-300 grudziądz petro other materials pharma environment","status":"active","updated_at":"2026-03-08T14:50:13.330Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-14T12:18:12.092Z","parse_date":"2026-08-14T12:18:12.092Z","parse_source":"agent-claude-code","email_confidence":"high","email_mx":true,"email_source":"https://www.opec.pl/laboratorium-2/","fields_of_testing":[{"codes":"C/10; C/32","pl":"Badania chemiczne paliw stałych, odpadów","en":"Chemical tests of solid fuels, waste"},{"codes":"N/10; N/32","pl":"Badanie właściwości fizycznych paliw stałych, odpadów","en":"Tests of physical properties of solid fuels, waste"}],"issue":{"no":"22","date":"11.05.2026"},"map_coord":[53.479304,18.772162],"map_geo":"nominatim-street","lab_locations":[{"name":"Laboratorium","address":"ul. Budowlanych 7","city":"Grudziądz","postal":"86-300"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/14/5cec817ce3ef56eeab63e27deafdbd73/AB%201040.pdf","has_en":true,"category_counts":{"petro":22,"environment":3},"category_scores":{"petro":19.36,"environment":0.36},"has_zh":true,"lab_locations_zh":[{"name":"实验室","address":"ul. Budowlanych 7","city":"Grudziądz","postal":"86-300"}]},"methods":[{"_id":"6a7f07841995264369d8e086","lab_id":"69ad52a3de79e566650fb544","country":"PL","accr_number":"AB 1040","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci przemijającej","parameters":[{"name":"Zakres","range":"(3,0 − 20,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci przemijającej\nZakres (3,0 − 20,0) %\nMetoda wagowa","reference":"PN-80/G-04511","norm_bases":["PN-80/G-04511"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci przemijającej\nZakres (3,0 − 20,0) %\nMetoda wagowa PN-80/G-04511 Paliwa stale: wegiel kamienny Zawartosc wilgoci przemijajacej\nZakres (3,0 − 20,0) %\nMetoda wagowa PN-80/G-04511","categories":["petro"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Free moisture content","parameters_en":[{"name":"Range","range":"(3,0 − 20,0) %"}],"search_en":"Solid fuels: hard coal Free moisture content Gravimetric method Laboratory Range PN-80/G-04511","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(3,0 − 20,0) %"}],"search_zh":"固体燃料：烟煤 外在水分含量 重量法 实验室 范围 PN-80/G-04511","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"外在水分含量"},{"_id":"6a7f07841995264369d8e087","lab_id":"69ad52a3de79e566650fb544","country":"PL","accr_number":"AB 1040","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,4 – 15,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,4 – 15,0) %\nMetoda wagowa","reference":"PN-80/G-04511","norm_bases":["PN-80/G-04511"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej\nZakres (0,4 – 15,0) %\nMetoda wagowa PN-80/G-04511 Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej\nZakres (0,4 – 15,0) %\nMetoda wagowa PN-80/G-04511","categories":["petro"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,4 – 15,0) %"}],"search_en":"Solid fuels: hard coal Moisture content in the analytical sample Gravimetric method Laboratory Range PN-80/G-04511","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","lab_section_zh":"实验室","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,4 – 15,0) %"}],"search_zh":"固体燃料：烟煤 分析样品水分含量 重量法 实验室 范围 PN-80/G-04511","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a7f07841995264369d8e088","lab_id":"69ad52a3de79e566650fb544","country":"PL","accr_number":"AB 1040","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci w węglu powietrznosuchym","parameters":[{"name":"Zakres","range":"(0,4 – 10,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w węglu powietrznosuchym\nZakres (0,4 – 10,0) %\nMetoda wagowa","reference":"PN-80/G-04511","norm_bases":["PN-80/G-04511"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w węglu powietrznosuchym\nZakres (0,4 – 10,0) %\nMetoda wagowa PN-80/G-04511 Paliwa stale: wegiel kamienny Zawartosc wilgoci w weglu powietrznosuchym\nZakres (0,4 – 10,0) %\nMetoda wagowa PN-80/G-04511","categories":["petro"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Moisture content in air-dried coal","parameters_en":[{"name":"Range","range":"(0,4 – 10,0) %"}],"search_en":"Solid fuels: hard coal Moisture content in air-dried coal Gravimetric method Laboratory Range PN-80/G-04511","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,4 – 10,0) %"}],"search_zh":"固体燃料：烟煤 重量法 实验室 范围 PN-80/G-04511","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a7f07841995264369d8e089","lab_id":"69ad52a3de79e566650fb544","country":"PL","accr_number":"AB 1040","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci całkowitej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wilgoci całkowitej (z obliczeń)","reference":"PN-80/G-04511 | PN-ISO 589:2006 Metoda A2","norm_bases":["PN-80/G-04511","PN-ISO 589:2006 Metoda A2"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej (z obliczeń) PN-80/G-04511 | PN-ISO 589:2006 Metoda A2 Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej (z obliczen) PN-80/G-04511 | PN-ISO 589:2006 Metoda A2","categories":["petro"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total moisture content (calculated)","search_en":"Solid fuels: hard coal Total moisture content (calculated) Laboratory PN-80/G-04511 | PN-ISO 589:2006 Metoda A2","test_object_en":"Solid fuels: hard coal","lab_section_zh":"实验室","search_zh":"固体燃料：烟煤 全水分含量（计算值） 实验室 PN-80/G-04511 | PN-ISO 589:2006 Metoda A2","test_object_zh":"固体燃料：烟煤","methodology_zh":"全水分含量（计算值）"},{"_id":"6a7f07841995264369d8e08a","lab_id":"69ad52a3de79e566650fb544","country":"PL","accr_number":"AB 1040","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(2,0 − 45,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu\nZakres (2,0 − 45,0) %\nMetoda wagowa","reference":"PN-ISO 1171:2002","norm_bases":["PN-ISO 1171:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu\nZakres (2,0 − 45,0) %\nMetoda wagowa PN-ISO 1171:2002 Paliwa stale: wegiel kamienny Zawartosc popiolu\nZakres (2,0 − 45,0) %\nMetoda wagowa PN-ISO 1171:2002","categories":["petro"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(2,0 − 45,0) %"}],"search_en":"Solid fuels: hard coal Ash content Gravimetric method Laboratory Range PN-ISO 1171:2002","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","lab_section_zh":"实验室","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(2,0 − 45,0) %"}],"search_zh":"固体燃料：烟煤 灰分含量 重量法 实验室 范围 PN-ISO 1171:2002","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a7f07841995264369d8e08b","lab_id":"69ad52a3de79e566650fb544","country":"PL","accr_number":"AB 1040","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(12000 − 32000) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)","range":null}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres:\nZakres (12000 − 32000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-81/G-04513","norm_bases":["PN-81/G-04513"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Ciepło spalania\nZakres:\nZakres (12000 − 32000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-81/G-04513 Paliwa stale: wegiel kamienny Cieplo spalania\nZakres:\nZakres (12000 − 32000) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-81/G-04513","categories":["petro"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(12000 − 32000) kJ/kg"},{"name":"Net calorific value (calculated)","range":null}],"search_en":"Solid fuels: hard coal Gross calorific value Calorimetric method Laboratory Range Net calorific value (calculated) PN-81/G-04513","technique_en":"Calorimetric method","test_object_en":"Solid fuels: hard coal","lab_section_zh":"实验室","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(12000 − 32000) kJ/kg"},{"name":"低位发热量（计算值）","range":null}],"search_zh":"固体燃料：烟煤 高位发热量 量热法 实验室 范围 低位发热量（计算值） PN-81/G-04513","technique_zh":"量热法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a7f07841995264369d8e08c","lab_id":"69ad52a3de79e566650fb544","country":"PL","accr_number":"AB 1040","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,10 – 3,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,10 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001 | ISO 19579:2006","norm_bases":["PN-G-04584:2001","ISO 19579:2006"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość siarki całkowitej\nZakres (0,10 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 | ISO 19579:2006 Paliwa stale: wegiel kamienny Zawartosc siarki calkowitej\nZakres (0,10 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001 | ISO 19579:2006","categories":["petro"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,10 – 3,00) %"}],"search_en":"Solid fuels: hard coal Total sulfur content High-temperature combustion with IR detection Laboratory Range PN-G-04584:2001 | ISO 19579:2006","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal","lab_section_zh":"实验室","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,10 – 3,00) %"}],"search_zh":"固体燃料：烟煤 全硫含量 高温燃烧红外检测法 实验室 范围 PN-G-04584:2001 | ISO 19579:2006","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a7f07841995264369d8e08d","lab_id":"69ad52a3de79e566650fb544","country":"PL","accr_number":"AB 1040","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(12,0 – 85,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres (12,0 – 85,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość węgla całkowitego\nZakres (12,0 – 85,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc wegla calkowitego\nZakres (12,0 – 85,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(12,0 – 85,0) %"}],"search_en":"Solid fuels: hard coal Total carbon content High-temperature combustion with IR detection Laboratory Range PN-G-04571:1998","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal","lab_section_zh":"实验室","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(12,0 – 85,0) %"}],"search_zh":"固体燃料：烟煤 总碳含量 高温燃烧红外检测法 实验室 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a7f07841995264369d8e08e","lab_id":"69ad52a3de79e566650fb544","country":"PL","accr_number":"AB 1040","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość chloru","parameters":[{"name":"Zakres","range":"(0,030 − 0,700) %"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Zawartość chloru\nZakres (0,030 − 0,700) %\nMetoda miareczkowania potencjometrycznego","reference":"PN-G-04534:2024-01","norm_bases":["PN-G-04534:2024-01"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość chloru\nZakres (0,030 − 0,700) %\nMetoda miareczkowania potencjometrycznego PN-G-04534:2024-01 Paliwa stale: wegiel kamienny Zawartosc chloru\nZakres (0,030 − 0,700) %\nMetoda miareczkowania potencjometrycznego PN-G-04534:2024-01","categories":["petro"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chlorine content","parameters_en":[{"name":"Range","range":"(0,030 − 0,700) %"}],"search_en":"Solid fuels: hard coal Chlorine content Potentiometric titration method Laboratory Range PN-G-04534:2024-01","technique_en":"Potentiometric titration method","test_object_en":"Solid fuels: hard coal","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,030 − 0,700) %"}],"search_zh":"固体燃料：烟煤 氯含量 电位滴定法 实验室 范围 PN-G-04534:2024-01","technique_zh":"电位滴定法","test_object_zh":"固体燃料：烟煤","methodology_zh":"氯含量"},{"_id":"6a7f07841995264369d8e08f","lab_id":"69ad52a3de79e566650fb544","country":"PL","accr_number":"AB 1040","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci pierwszego stopnia (przemijającej)","parameters":[{"name":"Zakres","range":"(1,0 − 30,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci pierwszego stopnia (przemijającej)\nZakres (1,0 − 30,0) %\nMetoda wagowa","reference":"PN-ISO 589:2006","norm_bases":["PN-ISO 589:2006"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci pierwszego stopnia (przemijającej)\nZakres (1,0 − 30,0) %\nMetoda wagowa PN-ISO 589:2006 Paliwa stale: wegiel kamienny Zawartosc wilgoci pierwszego stopnia (przemijajacej)\nZakres (1,0 − 30,0) %\nMetoda wagowa PN-ISO 589:2006","categories":["petro"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"First-stage (free) moisture content","parameters_en":[{"name":"Range","range":"(1,0 − 30,0) %"}],"search_en":"Solid fuels: hard coal First-stage (free) moisture content Gravimetric method Laboratory Range PN-ISO 589:2006","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(1,0 − 30,0) %"}],"search_zh":"固体燃料：烟煤 第一阶段水分（外在水分）含量 重量法 实验室 范围 PN-ISO 589:2006","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"第一阶段水分（外在水分）含量"},{"_id":"6a7f07841995264369d8e090","lab_id":"69ad52a3de79e566650fb544","country":"PL","accr_number":"AB 1040","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci drugiego stopnia (wilgoci pozostałej w próbce)","parameters":[{"name":"Zakres","range":"(1,0 – 15,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci drugiego stopnia (wilgoci pozostałej w próbce)\nZakres (1,0 – 15,0) %\nMetoda wagowa","reference":"PN-ISO 589:2006 Metoda A2","norm_bases":["PN-ISO 589:2006 Metoda A2"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci drugiego stopnia (wilgoci pozostałej w próbce)\nZakres (1,0 – 15,0) %\nMetoda wagowa PN-ISO 589:2006 Metoda A2 Paliwa stale: wegiel kamienny Zawartosc wilgoci drugiego stopnia (wilgoci pozostalej w probce)\nZakres (1,0 – 15,0) %\nMetoda wagowa PN-ISO 589:2006 Metoda A2","categories":["petro"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Second-stage moisture content (moisture remaining in the sample)","parameters_en":[{"name":"Range","range":"(1,0 – 15,0) %"}],"search_en":"Solid fuels: hard coal Second-stage moisture content (moisture remaining in the sample) Gravimetric method Laboratory Range PN-ISO 589:2006 Metoda A2","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(1,0 – 15,0) %"}],"search_zh":"固体燃料：烟煤 第二阶段水分（样品残余水分）含量 重量法 实验室 范围 PN-ISO 589:2006 Metoda A2","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"第二阶段水分（样品残余水分）含量"},{"_id":"6a7f07841995264369d8e091","lab_id":"69ad52a3de79e566650fb544","country":"PL","accr_number":"AB 1040","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(1,0 – 15,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (1,0 – 15,0) %\nMetoda wagowa","reference":"PN-ISO 11722:2009","norm_bases":["PN-ISO 11722:2009"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej\nZakres (1,0 – 15,0) %\nMetoda wagowa PN-ISO 11722:2009 Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej\nZakres (1,0 – 15,0) %\nMetoda wagowa PN-ISO 11722:2009","categories":["petro"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(1,0 – 15,0) %"}],"search_en":"Solid fuels: hard coal Moisture content in the analytical sample Gravimetric method Laboratory Range PN-ISO 11722:2009","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","lab_section_zh":"实验室","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 15,0) %"}],"search_zh":"固体燃料：烟煤 分析样品水分含量 重量法 实验室 范围 PN-ISO 11722:2009","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a7f07841995264369d8e092","lab_id":"69ad52a3de79e566650fb544","country":"PL","accr_number":"AB 1040","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(12000 − 34000) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)","range":null}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres:\nZakres (12000 − 34000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-ISO 1928:2020-05","norm_bases":["PN-ISO 1928:2020-05"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Ciepło spalania\nZakres:\nZakres (12000 − 34000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-ISO 1928:2020-05 Paliwa stale: wegiel kamienny Cieplo spalania\nZakres:\nZakres (12000 − 34000) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-ISO 1928:2020-05","categories":["petro"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(12000 − 34000) kJ/kg"},{"name":"Net calorific value (calculated)","range":null}],"search_en":"Solid fuels: hard coal Gross calorific value Calorimetric method Laboratory Range Net calorific value (calculated) PN-ISO 1928:2020-05","technique_en":"Calorimetric method","test_object_en":"Solid fuels: hard coal","lab_section_zh":"实验室","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(12000 − 34000) kJ/kg"},{"name":"低位发热量（计算值）","range":null}],"search_zh":"固体燃料：烟煤 高位发热量 量热法 实验室 范围 低位发热量（计算值） PN-ISO 1928:2020-05","technique_zh":"量热法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a7f07841995264369d8e093","lab_id":"69ad52a3de79e566650fb544","country":"PL","accr_number":"AB 1040","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wodoru","parameters":[{"name":"Zakres","range":"(2,00 − 5,50) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość wodoru\nZakres (2,00 − 5,50) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wodoru\nZakres (2,00 − 5,50) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc wodoru\nZakres (2,00 − 5,50) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Hydrogen content","parameters_en":[{"name":"Range","range":"(2,00 − 5,50) %"}],"search_en":"Solid fuels: hard coal Hydrogen content High-temperature combustion with IR detection Laboratory Range PN-G-04571:1998","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(2,00 − 5,50) %"}],"search_zh":"固体燃料：烟煤 氢含量 高温燃烧红外检测法 实验室 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤","methodology_zh":"氢含量"},{"_id":"6a7f07841995264369d8e094","lab_id":"69ad52a3de79e566650fb544","country":"PL","accr_number":"AB 1040","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość wilgoci całkowitej","parameters":[{"name":"Zakres","range":"(2,0 − 60,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci całkowitej\nZakres (2,0 − 60,0) %\nMetoda wagowa","reference":"PN-EN ISO 18134-2:2024-10","norm_bases":["PN-EN ISO 18134-2:2024-10"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość wilgoci całkowitej\nZakres (2,0 − 60,0) %\nMetoda wagowa PN-EN ISO 18134-2:2024-10 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc wilgoci calkowitej\nZakres (2,0 − 60,0) %\nMetoda wagowa PN-EN ISO 18134-2:2024-10","categories":["petro"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total moisture content","parameters_en":[{"name":"Range","range":"(2,0 − 60,0) %"}],"search_en":"Solid fuels: solid biomass – solid biofuel Total moisture content Gravimetric method Laboratory Range PN-EN ISO 18134-2:2024-10","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid biomass – solid biofuel","lab_section_zh":"实验室","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(2,0 − 60,0) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 全水分含量 重量法 实验室 范围 PN-EN ISO 18134-2:2024-10","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a7f07841995264369d8e095","lab_id":"69ad52a3de79e566650fb544","country":"PL","accr_number":"AB 1040","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(12,0 − 60,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres (12,0 − 60,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 16948:2015-07","norm_bases":["PN-EN ISO 16948:2015-07"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość węgla całkowitego\nZakres (12,0 − 60,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 16948:2015-07 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc wegla calkowitego\nZakres (12,0 − 60,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 16948:2015-07","categories":["petro"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(12,0 − 60,0) %"}],"search_en":"Solid fuels: solid biomass – solid biofuel Total carbon content High-temperature combustion with IR detection Laboratory Range PN-EN ISO 16948:2015-07","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: solid biomass – solid biofuel","lab_section_zh":"实验室","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(12,0 − 60,0) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 总碳含量 高温燃烧红外检测法 实验室 范围 PN-EN ISO 16948:2015-07","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a7f07841995264369d8e096","lab_id":"69ad52a3de79e566650fb544","country":"PL","accr_number":"AB 1040","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość chloru","parameters":[{"name":"Zakres","range":"(0,005 – 1,300) %"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Zawartość chloru\nZakres (0,005 – 1,300) %\nMetoda miareczkowania potencjometrycznego","reference":"PN-EN ISO 16994:2016-10","norm_bases":["PN-EN ISO 16994:2016-10"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość chloru\nZakres (0,005 – 1,300) %\nMetoda miareczkowania potencjometrycznego PN-EN ISO 16994:2016-10 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc chloru\nZakres (0,005 – 1,300) %\nMetoda miareczkowania potencjometrycznego PN-EN ISO 16994:2016-10","categories":["petro"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chlorine content","parameters_en":[{"name":"Range","range":"(0,005 – 1,300) %"}],"search_en":"Solid fuels: solid biomass – solid biofuel Chlorine content Potentiometric titration method Laboratory Range PN-EN ISO 16994:2016-10","technique_en":"Potentiometric titration method","test_object_en":"Solid fuels: solid biomass – solid biofuel","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,005 – 1,300) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 氯含量 电位滴定法 实验室 范围 PN-EN ISO 16994:2016-10","technique_zh":"电位滴定法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料","methodology_zh":"氯含量"},{"_id":"6a7f07841995264369d8e097","lab_id":"69ad52a3de79e566650fb544","country":"PL","accr_number":"AB 1040","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,5 – 40,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,5 – 40,0) %\nMetoda wagowa","reference":"PN-EN ISO 18134-3:2023-12","norm_bases":["PN-EN ISO 18134-3:2023-12"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość wilgoci w próbce analitycznej\nZakres (0,5 – 40,0) %\nMetoda wagowa PN-EN ISO 18134-3:2023-12 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc wilgoci w probce analitycznej\nZakres (0,5 – 40,0) %\nMetoda wagowa PN-EN ISO 18134-3:2023-12","categories":["petro"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,5 – 40,0) %"}],"search_en":"Solid fuels: solid biomass – solid biofuel Moisture content in the analytical sample Gravimetric method Laboratory Range PN-EN ISO 18134-3:2023-12","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid biomass – solid biofuel","lab_section_zh":"实验室","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,5 – 40,0) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 分析样品水分含量 重量法 实验室 范围 PN-EN ISO 18134-3:2023-12","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a7f07841995264369d8e098","lab_id":"69ad52a3de79e566650fb544","country":"PL","accr_number":"AB 1040","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(0,3 – 40,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu\nZakres (0,3 – 40,0) %\nMetoda wagowa","reference":"PN-EN ISO 18122:2023-05","norm_bases":["PN-EN ISO 18122:2023-05"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość popiołu\nZakres (0,3 – 40,0) %\nMetoda wagowa PN-EN ISO 18122:2023-05 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc popiolu\nZakres (0,3 – 40,0) %\nMetoda wagowa PN-EN ISO 18122:2023-05","categories":["petro"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(0,3 – 40,0) %"}],"search_en":"Solid fuels: solid biomass – solid biofuel Ash content Gravimetric method Laboratory Range PN-EN ISO 18122:2023-05","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid biomass – solid biofuel","lab_section_zh":"实验室","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,3 – 40,0) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 灰分含量 重量法 实验室 范围 PN-EN ISO 18122:2023-05","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a7f07841995264369d8e099","lab_id":"69ad52a3de79e566650fb544","country":"PL","accr_number":"AB 1040","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość wodoru","parameters":[{"name":"Zakres","range":"(2,0 – 8,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość wodoru\nZakres (2,0 – 8,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 16948:2015-07","norm_bases":["PN-EN ISO 16948:2015-07"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość wodoru\nZakres (2,0 – 8,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 16948:2015-07 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc wodoru\nZakres (2,0 – 8,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 16948:2015-07","categories":["petro"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Hydrogen content","parameters_en":[{"name":"Range","range":"(2,0 – 8,0) %"}],"search_en":"Solid fuels: solid biomass – solid biofuel Hydrogen content High-temperature combustion with IR detection Laboratory Range PN-EN ISO 16948:2015-07","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: solid biomass – solid biofuel","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(2,0 – 8,0) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 氢含量 高温燃烧红外检测法 实验室 范围 PN-EN ISO 16948:2015-07","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料","methodology_zh":"氢含量"},{"_id":"6a7f07841995264369d8e09a","lab_id":"69ad52a3de79e566650fb544","country":"PL","accr_number":"AB 1040","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,01 – 2,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,01 – 2,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 16994:2016-10","norm_bases":["PN-EN ISO 16994:2016-10"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość siarki całkowitej\nZakres (0,01 – 2,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 16994:2016-10 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc siarki calkowitej\nZakres (0,01 – 2,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 16994:2016-10","categories":["petro"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,01 – 2,00) %"}],"search_en":"Solid fuels: solid biomass – solid biofuel Total sulfur content High-temperature combustion with IR detection Laboratory Range PN-EN ISO 16994:2016-10","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: solid biomass – solid biofuel","lab_section_zh":"实验室","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,01 – 2,00) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 全硫含量 高温燃烧红外检测法 实验室 范围 PN-EN ISO 16994:2016-10","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a7f07841995264369d8e09b","lab_id":"69ad52a3de79e566650fb544","country":"PL","accr_number":"AB 1040","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(7000 – 27000) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)","range":null}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres:\nZakres (7000 – 27000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-EN ISO 18125:2017-07","norm_bases":["PN-EN ISO 18125:2017-07"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Ciepło spalania\nZakres:\nZakres (7000 – 27000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-EN ISO 18125:2017-07 Paliwa stale: biomasa stala – biopaliwo stale Cieplo spalania\nZakres:\nZakres (7000 – 27000) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-EN ISO 18125:2017-07","categories":["petro"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(7000 – 27000) kJ/kg"},{"name":"Net calorific value (calculated)","range":null}],"search_en":"Solid fuels: solid biomass – solid biofuel Gross calorific value Calorimetric method Laboratory Range Net calorific value (calculated) PN-EN ISO 18125:2017-07","technique_en":"Calorimetric method","test_object_en":"Solid fuels: solid biomass – solid biofuel","lab_section_zh":"实验室","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(7000 – 27000) kJ/kg"},{"name":"低位发热量（计算值）","range":null}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 高位发热量 量热法 实验室 范围 低位发热量（计算值） PN-EN ISO 18125:2017-07","technique_zh":"量热法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a7f07841995264369d8e09c","lab_id":"69ad52a3de79e566650fb544","country":"PL","accr_number":"AB 1040","accr_body":"PCA","test_object":"Odpady O) kod: 10 01 01, 10 01 02, 10 01 80,","methodology":"Zawartość części palnych (straty przy prażeniu)","parameters":[{"name":"Zakres","range":"(0,50 − 50,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość części palnych (straty przy prażeniu)\nZakres (0,50 − 50,00) %\nMetoda wagowa","reference":"PN-77/G-04528/02","norm_bases":["PN-77/G-04528/02"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":"O) Kody badanych odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O) kod: 10 01 01, 10 01 02, 10 01 80, Zawartość części palnych (straty przy prażeniu)\nZakres (0,50 − 50,00) %\nMetoda wagowa PN-77/G-04528/02 Odpady O) kod: 10 01 01, 10 01 02, 10 01 80, Zawartosc czesci palnych (straty przy prazeniu)\nZakres (0,50 − 50,00) %\nMetoda wagowa PN-77/G-04528/02","categories":["environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","parameters_en":[{"name":"Range","range":"(0,50 − 50,00) %"}],"search_en":"Gravimetric method Laboratory Range PN-77/G-04528/02","technique_en":"Gravimetric method","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,50 − 50,00) %"}],"search_zh":"重量法 实验室 范围 PN-77/G-04528/02","technique_zh":"重量法"},{"_id":"6a7f07841995264369d8e09d","lab_id":"69ad52a3de79e566650fb544","country":"PL","accr_number":"AB 1040","accr_body":"PCA","test_object":"Odpady O) kod: 10 01 01, 10 01 02, 10 01 05, 10 01 80, 10 01 82","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(0,50 − 42,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres (0,50 − 42,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"IL-137 PT-05 wydanie 8 z dnia 11.12.2025 r.","norm_bases":["IL-137 PT-05 wydanie 8 z dnia 11.12.2025 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":"O) Kody badanych odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O) kod: 10 01 01, 10 01 02, 10 01 05, 10 01 80, 10 01 82 Zawartość węgla całkowitego\nZakres (0,50 − 42,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR IL-137 PT-05 wydanie 8 z dnia 11.12.2025 r. Odpady O) kod: 10 01 01, 10 01 02, 10 01 05, 10 01 80, 10 01 82 Zawartosc wegla calkowitego\nZakres (0,50 − 42,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR IL-137 PT-05 wydanie 8 z dnia 11.12.2025 r.","categories":["environment"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(0,50 − 42,00) %"}],"search_en":"Total carbon content High-temperature combustion with IR detection Laboratory Range IL-137 PT-05 wydanie 8 z dnia 11.12.2025 r.","technique_en":"High-temperature combustion with IR detection","lab_section_zh":"实验室","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(0,50 − 42,00) %"}],"search_zh":"总碳含量 高温燃烧红外检测法 实验室 范围 IL-137 PT-05 wydanie 8 z dnia 11.12.2025 r.","technique_zh":"高温燃烧红外检测法"},{"_id":"6a7f07841995264369d8e09e","lab_id":"69ad52a3de79e566650fb544","country":"PL","accr_number":"AB 1040","accr_body":"PCA","test_object":"Odpady O) kod: 10 01 01, 10 01 02, 10 01 05, 10 01 80, 10 01 82","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,2 − 10,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,2 − 10,0) %\nMetoda wagowa","reference":"IL-138 PT-06 wydanie 4 z dnia 11.12.2025 r.","norm_bases":["IL-138 PT-06 wydanie 4 z dnia 11.12.2025 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":"O) Kody badanych odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O) kod: 10 01 01, 10 01 02, 10 01 05, 10 01 80, 10 01 82 Zawartość wilgoci w próbce analitycznej\nZakres (0,2 − 10,0) %\nMetoda wagowa IL-138 PT-06 wydanie 4 z dnia 11.12.2025 r. Odpady O) kod: 10 01 01, 10 01 02, 10 01 05, 10 01 80, 10 01 82 Zawartosc wilgoci w probce analitycznej\nZakres (0,2 − 10,0) %\nMetoda wagowa IL-138 PT-06 wydanie 4 z dnia 11.12.2025 r.","categories":["environment"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,2 − 10,0) %"}],"search_en":"Moisture content in the analytical sample Gravimetric method Laboratory Range IL-138 PT-06 wydanie 4 z dnia 11.12.2025 r.","technique_en":"Gravimetric method","lab_section_zh":"实验室","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,2 − 10,0) %"}],"search_zh":"分析样品水分含量 重量法 实验室 范围 IL-138 PT-06 wydanie 4 z dnia 11.12.2025 r.","technique_zh":"重量法"}],"has_pdf":true}