{"lab":{"_id":"69ad52a3de79e566650fb53c","accr_number":"AB 1036","country":"PL","accr_body":"PCA","address":"Sp. z o.o., ul. Naruszewicza 18, 35-055 Rzeszów, LABORATORIUM CENTRALNE","categories":["water","environment","microbiology","materials"],"city":"Rzeszów","imported_at":"2026-03-08T10:42:43.265Z","methods_count":71,"name":"MIEJSKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1036.pdf"],"scope_summary":"","search_text":"miejskie przedsiębiorstwo wodociągów i kanalizacji sp. z o.o., ul. naruszewicza 18, 35-055 rzeszów, laboratorium centralne water other materials environment pharma electronics microbiology","status":"active","updated_at":"2026-03-08T14:50:13.012Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-14T12:20:13.230Z","parse_date":"2026-08-14T12:20:13.230Z","parse_source":"agent-claude-code","email_confidence":"high","email_mx":true,"email_source":"https://mpwik.rzeszow.pl/laboratorium/kontak-laboratorium-centralne/","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P; C/32/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, osadów, odpadów","en":"Chemical tests and sampling of water, drinking water, sewage, sediments, waste"},{"codes":"K/28","pl":"Badania mikrobiologiczne wody","en":"Microbiological tests of water"},{"codes":"K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody do spożycia przez ludzi","en":"Microbiological tests and sampling of drinking water"},{"codes":"N/28/P; N/29/P; N/30/P; N/32/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, osadów, odpadów","en":"Tests of physical properties and sampling of water, drinking water, sewage, sediments, waste"}],"issue":{"no":"20","date":"13.03.2026"},"map_coord":[50.035419,22.010738],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM CENTRALNE","address":"ul. Ciepłownicza 7 A, 35-959 Rzeszów","city":"Rzeszów","postal":"35-959"},{"name":"Pracownia Ścieków","address":"ul. Ciepłownicza 7 A, 35-959 Rzeszów","city":"Rzeszów","postal":"35-959"},{"name":"Pracownia Wody","address":"ul. Zwięczycka 36, 35-083 Rzeszów","city":"Rzeszów","postal":"35-083"},{"name":"Pracownia Mikrobiologii","address":"ul. Zwięczycka 36, 35-083 Rzeszów","city":"Rzeszów","postal":"35-083"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/14/8175cbf4fe1f66bd81e598562c572adb/AB%201036.pdf","has_en":true,"category_counts":{"water":64,"environment":7,"microbiology":4,"materials":4},"category_scores":{"water":51.85,"environment":0.62,"microbiology":0.2,"materials":0.2},"has_zh":true,"lab_locations_zh":[{"name":"LABORATORIUM CENTRALNE","address":"ul. Ciepłownicza 7 A, 35-959 Rzeszów","city":"Rzeszów","postal":"35-959"},{"name":"废水实验室","address":"ul. Ciepłownicza 7 A, 35-959 Rzeszów","city":"Rzeszów","postal":"35-959"},{"name":"Pracownia Wody","address":"ul. Zwięczycka 36, 35-083 Rzeszów","city":"Rzeszów","postal":"35-083"},{"name":"微生物室","address":"ul. Zwięczycka 36, 35-083 Rzeszów","city":"Rzeszów","postal":"35-083"}]},"methods":[{"_id":"6a7f07fd1995264369d8e11e","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Wody opadowe, wody roztopowe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody opadowe, wody roztopowe Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11 Wody opadowe, wody roztopowe Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Rainwater, snowmelt water Sampling for chemical and physical testing Manual method Wastewater Laboratory PN-ISO 5667-10:2021-11","technique_en":"Manual method","test_object_en":"Rainwater, snowmelt water","methodology_zh":"化学与物理检测用样品采集","search_zh":"雨水、融雪水 化学与物理检测用样品采集 手工法 废水实验室 PN-ISO 5667-10:2021-11","test_object_zh":"雨水、融雪水","technique_zh":"手工法","lab_section_zh":"废水实验室"},{"_id":"6a7f07fd1995264369d8e11f","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method Wastewater Laboratory PN-ISO 5667-10:2021-11","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 废水实验室 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"污水","lab_section_zh":"废水实验室"},{"_id":"6a7f07fd1995264369d8e120","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Ścieki","methodology":"Temperatura ścieków/pobranej próbki ścieków","parameters":[{"name":"Zakres","range":"(0,0 – 60,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura ścieków/pobranej próbki ścieków\nZakres (0,0 – 60,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Temperatura ścieków/pobranej próbki ścieków\nZakres (0,0 – 60,0) °C PN-77/C-04584 Scieki Temperatura sciekow/pobranej probki sciekow\nZakres (0,0 – 60,0) °C PN-77/C-04584","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Temperature of wastewater/collected wastewater sample","parameters_en":[{"name":"Range","range":"(0,0 – 60,0) °C"}],"search_en":"Wastewater Temperature of wastewater/collected wastewater sample Wastewater Laboratory Range PN-77/C-04584","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,0 – 60,0) °C"}],"search_zh":"污水 废水/所采废水样品的温度 废水实验室 范围 PN-77/C-04584","test_object_zh":"污水","lab_section_zh":"废水实验室","methodology_zh":"废水/所采废水样品的温度"},{"_id":"6a7f07fd1995264369d8e121","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu fosforanowego","parameters":[{"name":"Zakres","range":"(0,04 – 40) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu fosforanowego\nZakres (0,04 – 40) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+ Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006+ Ap1:2010 +Ap2:2010"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu fosforanowego\nZakres (0,04 – 40) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+ Ap1:2010 +Ap2:2010 Scieki Stezenie fosforu fosforanowego\nZakres (0,04 – 40) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+ Ap1:2010 +Ap2:2010","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Phosphate phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,04 – 40) mg/l"}],"search_en":"Wastewater Phosphate phosphorus concentration Spectrophotometric method Wastewater Laboratory Range PN-EN ISO 6878:2006+ Ap1:2010 +Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,04 – 40) mg/l"}],"search_zh":"污水 磷酸盐磷浓度 分光光度法 废水实验室 范围 PN-EN ISO 6878:2006+ Ap1:2010 +Ap2:2010","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"废水实验室","methodology_zh":"磷酸盐磷浓度"},{"_id":"6a7f07fd1995264369d8e122","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,04 – 40) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,04 – 40) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p.8 +Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 p.8 +Ap1:2010 +Ap2:2010"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,04 – 40) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p.8 +Ap1:2010 +Ap2:2010 Scieki Stezenie fosforu ogolnego\nZakres (0,04 – 40) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p.8 +Ap1:2010 +Ap2:2010","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,04 – 40) mg/l"}],"search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Wastewater Laboratory Range PN-EN ISO 6878:2006 p.8 +Ap1:2010 +Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 40) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 废水实验室 范围 PN-EN ISO 6878:2006 p.8 +Ap1:2010 +Ap2:2010","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"废水实验室"},{"_id":"6a7f07fd1995264369d8e123","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,05 – 250) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,05 – 250) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (0,05 – 250) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Scieki Stezenie azotu amonowego\nZakres (0,05 – 250) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,05 – 250) mg/l"}],"search_en":"Wastewater Ammonium nitrogen concentration Spectrophotometric method Wastewater Laboratory Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 250) mg/l"}],"search_zh":"污水 氨氮浓度 分光光度法 废水实验室 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"废水实验室"},{"_id":"6a7f07fd1995264369d8e124","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr","parameters":[{"name":"Zakres","range":"(10 – 10000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (10 – 10000) mg/l O2\nMetoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (10 – 10000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006 Scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (10 – 10000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Chemical oxygen demand - COD-Cr","parameters_en":[{"name":"Range","range":"(10 – 10000) mg/l O2"}],"search_en":"Wastewater Chemical oxygen demand - COD-Cr Titrimetric method Wastewater Laboratory Range PN-ISO 6060:2006","technique_en":"Titrimetric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(10 – 10000) mg/l O2"}],"search_zh":"污水 化学需氧量（COD-Cr） 滴定法 废水实验室 范围 PN-ISO 6060:2006","technique_zh":"滴定法","test_object_zh":"污水","methodology_zh":"化学需氧量（COD-Cr）","lab_section_zh":"废水实验室"},{"_id":"6a7f07fd1995264369d8e125","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Wastewater pH Potentiometric method Wastewater Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"污水 pH 值 电位法 废水实验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"污水","lab_section_zh":"废水实验室"},{"_id":"6a7f07fd1995264369d8e126","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,05 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,05 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotanowego\nZakres (0,05 – 100) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Scieki Stezenie azotu azotanowego\nZakres (0,05 – 100) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,05 – 100) mg/l"}],"search_en":"Wastewater Nitrate nitrogen concentration Spectrophotometric method Wastewater Laboratory Range PN-82/C-04576/08","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 100) mg/l"}],"search_zh":"污水 硝态氮浓度 分光光度法 废水实验室 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"废水实验室"},{"_id":"6a7f07fd1995264369d8e127","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,010 – 25,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,010 – 25,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotynowego\nZakres (0,010 – 25,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Scieki Stezenie azotu azotynowego\nZakres (0,010 – 25,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,010 – 25,0) mg/l"}],"search_en":"Wastewater Nitrite nitrogen concentration Spectrophotometric method Wastewater Laboratory Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 25,0) mg/l"}],"search_zh":"污水 亚硝态氮浓度 分光光度法 废水实验室 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"废水实验室"},{"_id":"6a7f07fd1995264369d8e128","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,50 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,50 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu Kjeldahla\nZakres (0,50 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Scieki Stezenie azotu Kjeldahla\nZakres (0,50 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,50 – 1000) mg/l"}],"search_en":"Wastewater Kjeldahl nitrogen concentration Titrimetric method Wastewater Laboratory Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,50 – 1000) mg/l"}],"search_zh":"污水 凯氏氮浓度 滴定法 废水实验室 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"污水","lab_section_zh":"废水实验室"},{"_id":"6a7f07fd1995264369d8e129","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576","norm_bases":["PN-73/C-04576"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576 Scieki Stezenie azotu ogolnego (z obliczen) PN-73/C-04576","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Wastewater Total nitrogen concentration (calculated) Wastewater Laboratory PN-73/C-04576","test_object_en":"Wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"污水 总氮浓度（计算值） 废水实验室 PN-73/C-04576","test_object_zh":"污水","lab_section_zh":"废水实验室"},{"_id":"6a7f07fd1995264369d8e12a","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 10000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 10000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chlorków\nZakres (5,0 – 10000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki Stezenie chlorkow\nZakres (5,0 – 10000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 10000) mg/l"}],"search_en":"Wastewater Chloride concentration Titrimetric method Wastewater Laboratory Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 10000) mg/l"}],"search_zh":"污水 氯化物浓度 滴定法 废水实验室 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"污水","lab_section_zh":"废水实验室"},{"_id":"6a7f07fd1995264369d8e12b","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Ścieki","methodology":"Indeks fenolowy","parameters":[{"name":"Zakres","range":"(0,100 – 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Indeks fenolowy\nZakres (0,100 – 50) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994 metoda A","norm_bases":["PN-ISO 6439:1994 metoda A"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Indeks fenolowy\nZakres (0,100 – 50) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 metoda A Scieki Indeks fenolowy\nZakres (0,100 – 50) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 metoda A","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Phenol index","parameters_en":[{"name":"Range","range":"(0,100 – 50) mg/l"}],"search_en":"Wastewater Phenol index Spectrophotometric method Wastewater Laboratory Range PN-ISO 6439:1994 metoda A","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,100 – 50) mg/l"}],"search_zh":"污水 酚指数 分光光度法 废水实验室 范围 PN-ISO 6439:1994 metoda A","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"酚指数","lab_section_zh":"废水实验室"},{"_id":"6a7f07fd1995264369d8e12c","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie cyjanków wolnych","parameters":[{"name":"Zakres","range":"(0,005 – 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie cyjanków wolnych\nZakres (0,005 – 50) mg/l\nMetoda spektrofotometryczna","reference":"PN-80/C-04603/01","norm_bases":["PN-80/C-04603/01"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie cyjanków wolnych\nZakres (0,005 – 50) mg/l\nMetoda spektrofotometryczna PN-80/C-04603/01 Scieki Stezenie cyjankow wolnych\nZakres (0,005 – 50) mg/l\nMetoda spektrofotometryczna PN-80/C-04603/01","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Free cyanide concentration","parameters_en":[{"name":"Range","range":"(0,005 – 50) mg/l"}],"search_en":"Wastewater Free cyanide concentration Spectrophotometric method Wastewater Laboratory Range PN-80/C-04603/01","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,005 – 50) mg/l"}],"search_zh":"污水 游离氰化物浓度 分光光度法 废水实验室 范围 PN-80/C-04603/01","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"废水实验室","methodology_zh":"游离氰化物浓度"},{"_id":"6a7f07fd1995264369d8e12d","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie surfaktantów anionowych","parameters":[{"name":"Zakres","range":"(0,10 – 1000) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie surfaktantów anionowych\nZakres (0,10 – 1000) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 903:2002","norm_bases":["PN-EN 903:2002"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie surfaktantów anionowych\nZakres (0,10 – 1000) mg/l\nMetoda spektrofotometryczna PN-EN 903:2002 Scieki Stezenie surfaktantow anionowych\nZakres (0,10 – 1000) mg/l\nMetoda spektrofotometryczna PN-EN 903:2002","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Anionic surfactant concentration","parameters_en":[{"name":"Range","range":"(0,10 – 1000) mg/l"}],"search_en":"Wastewater Anionic surfactant concentration Spectrophotometric method Wastewater Laboratory Range PN-EN 903:2002","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,10 – 1000) mg/l"}],"search_zh":"污水 阴离子表面活性剂浓度 分光光度法 废水实验室 范围 PN-EN 903:2002","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"废水实验室","methodology_zh":"阴离子表面活性剂浓度"},{"_id":"6a7f07fd1995264369d8e12e","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie substancji ekstrahujących się eterem naftowym","parameters":[{"name":"Zakres","range":"(6,0 – 10000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym\nZakres (6,0 – 10000) mg/l\nMetoda wagowa","reference":"PB-13/PS wydanie 3 z dnia 30.10.2024 r.","norm_bases":["PB-13/PS wydanie 3 z dnia 30.10.2024 r."],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie substancji ekstrahujących się eterem naftowym\nZakres (6,0 – 10000) mg/l\nMetoda wagowa PB-13/PS wydanie 3 z dnia 30.10.2024 r. Scieki Stezenie substancji ekstrahujacych sie eterem naftowym\nZakres (6,0 – 10000) mg/l\nMetoda wagowa PB-13/PS wydanie 3 z dnia 30.10.2024 r.","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Concentration of substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(6,0 – 10000) mg/l"}],"search_en":"Wastewater Concentration of substances extractable with petroleum ether Gravimetric method Wastewater Laboratory Range PB-13/PS wydanie 3 z dnia 30.10.2024 r.","technique_en":"Gravimetric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(6,0 – 10000) mg/l"}],"search_zh":"污水 石油醚可萃取物浓度 重量法 废水实验室 范围 PB-13/PS wydanie 3 z dnia 30.10.2024 r.","technique_zh":"重量法","test_object_zh":"污水","methodology_zh":"石油醚可萃取物浓度","lab_section_zh":"废水实验室"},{"_id":"6a7f07fd1995264369d8e12f","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chromu (VI)","parameters":[{"name":"Zakres","range":"(0,01 – 20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chromu (VI)\nZakres (0,01 – 20) mg/l\nMetoda spektrofotometryczna","reference":"PN-77/C-04604/08","norm_bases":["PN-77/C-04604/08"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chromu (VI)\nZakres (0,01 – 20) mg/l\nMetoda spektrofotometryczna PN-77/C-04604/08 Scieki Stezenie chromu (VI)\nZakres (0,01 – 20) mg/l\nMetoda spektrofotometryczna PN-77/C-04604/08","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Chromium(VI) concentration","parameters_en":[{"name":"Range","range":"(0,01 – 20) mg/l"}],"search_en":"Wastewater Chromium(VI) concentration Spectrophotometric method Wastewater Laboratory Range PN-77/C-04604/08","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,01 – 20) mg/l"}],"search_zh":"污水 六价铬浓度 分光光度法 废水实验室 范围 PN-77/C-04604/08","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"六价铬浓度","lab_section_zh":"废水实验室"},{"_id":"6a7f07fd1995264369d8e130","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie metali","parameters":[{"name":"ołów","range":"(0,05 – 50) mg/l"},{"name":"kadm","range":"(0,02 – 20) mg/l"},{"name":"nikiel","range":"(0,05 – 1000) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie metali\nZakres:\nołów (0,05 – 50) mg/l\nkadm (0,02 – 20) mg/l\nnikiel (0,05 – 1000) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 Metoda A","norm_bases":["PN-ISO 8288:2002 Metoda A"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie metali\nZakres:\nołów (0,05 – 50) mg/l\nkadm (0,02 – 20) mg/l\nnikiel (0,05 – 1000) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 Metoda A Scieki Stezenie metali\nZakres:\nolow (0,05 – 50) mg/l\nkadm (0,02 – 20) mg/l\nnikiel (0,05 – 1000) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 Metoda A","categories":["materials","water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Metal concentrations","parameters_en":[{"name":"lead","range":"(0,05 – 50) mg/l"},{"name":"cadmium","range":"(0,02 – 20) mg/l"},{"name":"nickel","range":"(0,05 – 1000) mg/l"}],"search_en":"Wastewater Metal concentrations Flame atomic absorption spectrometry (FAAS) Wastewater Laboratory lead cadmium nickel PN-ISO 8288:2002 Metoda A","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Wastewater","methodology_zh":"金属浓度","parameters_zh":[{"name":"铅","range":"(0,05 – 50) mg/l"},{"name":"镉","range":"(0,02 – 20) mg/l"},{"name":"镍","range":"(0,05 – 1000) mg/l"}],"search_zh":"污水 金属浓度 火焰原子吸收光谱法（FAAS） 废水实验室 铅 镉 镍 PN-ISO 8288:2002 Metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"污水","lab_section_zh":"废水实验室"},{"_id":"6a7f07fd1995264369d8e131","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10 – 5000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie siarczanów\nZakres (10 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Scieki Stezenie siarczanow\nZakres (10 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10 – 5000) mg/l"}],"search_en":"Wastewater Sulfate concentration Gravimetric method Wastewater Laboratory Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 – 5000) mg/l"}],"search_zh":"污水 硫酸盐浓度 重量法 废水实验室 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"污水","lab_section_zh":"废水实验室"},{"_id":"6a7f07fd1995264369d8e132","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(1 – 10000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 10000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 10000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 10000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(1 – 10000) mg/l O2"}],"search_en":"Wastewater Biochemical oxygen demand - BOD5 Optical method Wastewater Laboratory Range PN-EN ISO 5815-1:2019-12","technique_en":"Optical method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(1 – 10000) mg/l O2"}],"search_zh":"污水 五日生化需氧量（BOD5） 光学法 废水实验室 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"污水","methodology_zh":"五日生化需氧量（BOD5）","lab_section_zh":"废水实验室"},{"_id":"6a7f07fd1995264369d8e133","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(1 – 1000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 1000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 1000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Woda Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 1000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(1 – 1000) mg/l O2"}],"search_en":"Water Biochemical oxygen demand - BOD5 Optical method Wastewater Laboratory Range PN-EN ISO 5815-1:2019-12","technique_en":"Optical method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(1 – 1000) mg/l O2"}],"search_zh":"水 五日生化需氧量（BOD5） 光学法 废水实验室 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"水","methodology_zh":"五日生化需氧量（BOD5）","lab_section_zh":"废水实验室"},{"_id":"6a7f07fd1995264369d8e134","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 10000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 10000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (2,0 – 10000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (2,0 – 10000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 10000) mg/l"}],"search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Wastewater Laboratory Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 10000) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 废水实验室 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水","lab_section_zh":"废水实验室"},{"_id":"6a7f07fd1995264369d8e135","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr","parameters":[{"name":"Zakres","range":"(10,0 – 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (10,0 – 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (10,0 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (10,0 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Chemical oxygen demand - COD-Cr","parameters_en":[{"name":"Range","range":"(10,0 – 10000) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand - COD-Cr Spectrophotometric method Wastewater Laboratory Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(10,0 – 10000) mg/l O2"}],"search_zh":"水、废水 化学需氧量（COD-Cr） 分光光度法 废水实验室 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"化学需氧量（COD-Cr）","lab_section_zh":"废水实验室"},{"_id":"6a7f07fd1995264369d8e136","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie metali","parameters":[{"name":"cynk","range":"(0,050 – 50) mg/l"},{"name":"miedź","range":"(0,020 – 50) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie metali\nZakres:\ncynk (0,050 – 50) mg/l\nmiedź (0,020 – 50) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 Metoda A","norm_bases":["PN-ISO 8288:2002 Metoda A"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie metali\nZakres:\ncynk (0,050 – 50) mg/l\nmiedź (0,020 – 50) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 Metoda A Woda, scieki Stezenie metali\nZakres:\ncynk (0,050 – 50) mg/l\nmiedz (0,020 – 50) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 Metoda A","categories":["materials","water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Metal concentrations","parameters_en":[{"name":"zinc","range":"(0,050 – 50) mg/l"},{"name":"copper","range":"(0,020 – 50) mg/l"}],"search_en":"Water, wastewater Metal concentrations Flame atomic absorption spectrometry (FAAS) Wastewater Laboratory zinc copper PN-ISO 8288:2002 Metoda A","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water, wastewater","methodology_zh":"金属浓度","parameters_zh":[{"name":"锌","range":"(0,050 – 50) mg/l"},{"name":"铜","range":"(0,020 – 50) mg/l"}],"search_zh":"水、废水 金属浓度 火焰原子吸收光谱法（FAAS） 废水实验室 锌 铜 PN-ISO 8288:2002 Metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、废水","lab_section_zh":"废水实验室"},{"_id":"6a7f07fd1995264369d8e137","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-13:2011 z wył. pkt 6.3.3, 6.3.4, 6.3.7, 6.3.8, 6.3.10","norm_bases":["PN-EN ISO 5667-13:2011 z wył. pkt 6.3.3, 6.3.4, 6.3.7, 6.3.8, 6.3.10"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-13:2011 z wył. pkt 6.3.3, 6.3.4, 6.3.7, 6.3.8, 6.3.10 Osady sciekowe Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-13:2011 z wyl. pkt 6.3.3, 6.3.4, 6.3.7, 6.3.8, 6.3.10","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Sewage sludge Sampling for chemical and physical testing Wastewater Laboratory PN-EN ISO 5667-13:2011 z wył. pkt 6.3.3, 6.3.4, 6.3.7, 6.3.8, 6.3.10","test_object_en":"Sewage sludge","methodology_zh":"化学与物理检测用样品采集","search_zh":"污泥 化学与物理检测用样品采集 废水实验室 PN-EN ISO 5667-13:2011 z wył. pkt 6.3.3, 6.3.4, 6.3.7, 6.3.8, 6.3.10","test_object_zh":"污泥","lab_section_zh":"废水实验室"},{"_id":"6a7f07fd1995264369d8e138","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"pH - w H2O","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH - w H2O\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe pH - w H2O\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Osady sciekowe pH - w H2O\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"pH - in H2O","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Sewage sludge pH - in H2O Potentiometric method Wastewater Laboratory Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"污泥 pH - 于 H2O 中 电位法 废水实验室 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"污泥","lab_section_zh":"废水实验室","methodology_zh":"pH - 于 H2O 中"},{"_id":"6a7f07fd1995264369d8e139","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość metali","parameters":[{"name":"nikiel","range":"(15,0 – 1000) mg/kg"},{"name":"chrom","range":"(15,0 – 2500) mg/kg"},{"name":"kadm","range":"(5,0 – 1000) mg/kg"},{"name":"cynk","range":"(15,0 – 5000) mg/kg"},{"name":"miedź","range":"(5,0 – 2000) mg/kg"},{"name":"ołów","range":"(15,0 – 1500) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość metali\nZakres:\nnikiel (15,0 – 1000) mg/kg\nchrom (15,0 – 2500) mg/kg\nkadm (5,0 – 1000) mg/kg\ncynk (15,0 – 5000) mg/kg\nmiedź (5,0 – 2000) mg/kg\nołów (15,0 – 1500) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN ISO 54321:2021-07 | PN-ISO 8288:2002 Metoda A","norm_bases":["PN-EN ISO 54321:2021-07","PN-ISO 8288:2002 Metoda A"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość metali\nZakres:\nnikiel (15,0 – 1000) mg/kg\nchrom (15,0 – 2500) mg/kg\nkadm (5,0 – 1000) mg/kg\ncynk (15,0 – 5000) mg/kg\nmiedź (5,0 – 2000) mg/kg\nołów (15,0 – 1500) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 54321:2021-07 | PN-ISO 8288:2002 Metoda A Osady sciekowe Zawartosc metali\nZakres:\nnikiel (15,0 – 1000) mg/kg\nchrom (15,0 – 2500) mg/kg\nkadm (5,0 – 1000) mg/kg\ncynk (15,0 – 5000) mg/kg\nmiedz (5,0 – 2000) mg/kg\nolow (15,0 – 1500) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 54321:2021-07 | PN-ISO 8288:2002 Metoda A","categories":["materials","water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Metal content","parameters_en":[{"name":"nickel","range":"(15,0 – 1000) mg/kg"},{"name":"chromium","range":"(15,0 – 2500) mg/kg"},{"name":"cadmium","range":"(5,0 – 1000) mg/kg"},{"name":"zinc","range":"(15,0 – 5000) mg/kg"},{"name":"copper","range":"(5,0 – 2000) mg/kg"},{"name":"lead","range":"(15,0 – 1500) mg/kg"}],"search_en":"Sewage sludge Metal content Flame atomic absorption spectrometry (FAAS) Wastewater Laboratory nickel chromium cadmium zinc copper lead PN-EN ISO 54321:2021-07 | PN-ISO 8288:2002 Metoda A","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Sewage sludge","parameters_zh":[{"name":"镍","range":"(15,0 – 1000) mg/kg"},{"name":"铬","range":"(15,0 – 2500) mg/kg"},{"name":"镉","range":"(5,0 – 1000) mg/kg"},{"name":"锌","range":"(15,0 – 5000) mg/kg"},{"name":"铜","range":"(5,0 – 2000) mg/kg"},{"name":"铅","range":"(15,0 – 1500) mg/kg"}],"search_zh":"污泥 金属含量 火焰原子吸收光谱法（FAAS） 废水实验室 镍 铬 镉 锌 铜 铅 PN-EN ISO 54321:2021-07 | PN-ISO 8288:2002 Metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"污泥","methodology_zh":"金属含量","lab_section_zh":"废水实验室"},{"_id":"6a7f07fd1995264369d8e13a","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Sucha pozostałość","parameters":[{"name":"Zakres","range":"(1,0 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość\nZakres (1,0 – 99,0) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02 metoda A","norm_bases":["PN-EN 15934:2013-02 metoda A"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Sucha pozostałość\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15934:2013-02 metoda A Osady sciekowe Sucha pozostalosc\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15934:2013-02 metoda A","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Dry residue","parameters_en":[{"name":"Range","range":"(1,0 – 99,0) %"}],"search_en":"Sewage sludge Dry residue Gravimetric method Wastewater Laboratory Range PN-EN 15934:2013-02 metoda A","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(1,0 – 99,0) %"}],"search_zh":"污泥 干残渣 重量法 废水实验室 范围 PN-EN 15934:2013-02 metoda A","technique_zh":"重量法","test_object_zh":"污泥","methodology_zh":"干残渣","lab_section_zh":"废水实验室"},{"_id":"6a7f07fd1995264369d8e13b","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Straty przy prażeniu suchej masy (LOI) / pozostałość po prażeniu","parameters":[{"name":"Zakres","range":"(0,5 – 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy (LOI) / pozostałość po prażeniu\nZakres (0,5 – 99,5) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Straty przy prażeniu suchej masy (LOI) / pozostałość po prażeniu\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 15935:2022-01 Osady sciekowe Straty przy prazeniu suchej masy (LOI) / pozostalosc po prazeniu\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Loss on ignition of dry matter (LOI) / residue on ignition","parameters_en":[{"name":"Range","range":"(0,5 – 99,5) %"}],"search_en":"Sewage sludge Loss on ignition of dry matter (LOI) / residue on ignition Gravimetric method Wastewater Laboratory Range PN-EN 15935:2022-01","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,5 – 99,5) %"}],"search_zh":"污泥 干物质烧失量（LOI）/ 灼烧残渣 重量法 废水实验室 范围 PN-EN 15935:2022-01","technique_zh":"重量法","test_object_zh":"污泥","lab_section_zh":"废水实验室","methodology_zh":"干物质烧失量（LOI）/ 灼烧残渣"},{"_id":"6a7f07fd1995264369d8e13c","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,10 – 7,5) %"},{"name":"Zakres","range":"(1000 – 75000) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu ogólnego\nZakres:\nZakres (0,10 – 7,5) %\nZakres (1000 – 75000) mg/kg\nMetoda spektrofotometryczna","reference":"PN-EN ISO 54321:2021-07 | PN-EN ISO 6878:2006 p. 8 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 54321:2021-07","PN-EN ISO 6878:2006 p. 8 +Ap1:2010+Ap2:2010"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość fosforu ogólnego\nZakres:\nZakres (0,10 – 7,5) %\nZakres (1000 – 75000) mg/kg\nMetoda spektrofotometryczna PN-EN ISO 54321:2021-07 | PN-EN ISO 6878:2006 p. 8 +Ap1:2010+Ap2:2010 Osady sciekowe Zawartosc fosforu ogolnego\nZakres:\nZakres (0,10 – 7,5) %\nZakres (1000 – 75000) mg/kg\nMetoda spektrofotometryczna PN-EN ISO 54321:2021-07 | PN-EN ISO 6878:2006 p. 8 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Total phosphorus content","parameters_en":[{"name":"Range","range":"(0,10 – 7,5) %"},{"name":"Range","range":"(1000 – 75000) mg/kg"}],"search_en":"Sewage sludge Total phosphorus content Spectrophotometric method Wastewater Laboratory Range Range PN-EN ISO 54321:2021-07 | PN-EN ISO 6878:2006 p. 8 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,10 – 7,5) %"},{"name":"范围","range":"(1000 – 75000) mg/kg"}],"search_zh":"污泥 总磷含量 分光光度法 废水实验室 范围 范围 PN-EN ISO 54321:2021-07 | PN-EN ISO 6878:2006 p. 8 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"污泥","methodology_zh":"总磷含量","lab_section_zh":"废水实验室"},{"_id":"6a7f07fd1995264369d8e13d","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość azotu ogólnego Kjeldahla","parameters":[{"name":"Zakres","range":"(0,10 – 10,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu ogólnego Kjeldahla\nZakres (0,10 – 10,0) %\nMetoda miareczkowa","reference":"PN-EN 13342: 2002-04","norm_bases":["PN-EN 13342: 2002-04"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość azotu ogólnego Kjeldahla\nZakres (0,10 – 10,0) %\nMetoda miareczkowa PN-EN 13342: 2002-04 Osady sciekowe Zawartosc azotu ogolnego Kjeldahla\nZakres (0,10 – 10,0) %\nMetoda miareczkowa PN-EN 13342: 2002-04","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Total Kjeldahl nitrogen content","parameters_en":[{"name":"Range","range":"(0,10 – 10,0) %"}],"search_en":"Sewage sludge Total Kjeldahl nitrogen content Titrimetric method Wastewater Laboratory Range PN-EN 13342: 2002-04","technique_en":"Titrimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,10 – 10,0) %"}],"search_zh":"污泥 凯氏总氮含量 滴定法 废水实验室 范围 PN-EN 13342: 2002-04","technique_zh":"滴定法","test_object_zh":"污泥","lab_section_zh":"废水实验室","methodology_zh":"凯氏总氮含量"},{"_id":"6a7f07fd1995264369d8e13e","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Odpady O): kod 19 08 05","methodology":"Pobieranie próbek do badań chemicznych, fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych","reference":"PN-EN ISO 5667-13:2011 z wył. pkt 6.3.3, 6.3.4, 6.3.7, 6.3.8, 6.3.10","norm_bases":["PN-EN ISO 5667-13:2011 z wył. pkt 6.3.3, 6.3.4, 6.3.7, 6.3.8, 6.3.10"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":"Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O): kod 19 08 05 Pobieranie próbek do badań chemicznych, fizycznych PN-EN ISO 5667-13:2011 z wył. pkt 6.3.3, 6.3.4, 6.3.7, 6.3.8, 6.3.10 Odpady O): kod 19 08 05 Pobieranie probek do badan chemicznych, fizycznych PN-EN ISO 5667-13:2011 z wyl. pkt 6.3.3, 6.3.4, 6.3.7, 6.3.8, 6.3.10","categories":["environment"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Sampling for chemical, physical testing","search_en":"Waste O): code 19 08 05 Sampling for chemical, physical testing Wastewater Laboratory PN-EN ISO 5667-13:2011 z wył. pkt 6.3.3, 6.3.4, 6.3.7, 6.3.8, 6.3.10","test_object_en":"Waste O): code 19 08 05","lab_section_zh":"废水实验室","search_zh":"废物 O)：代码 19 08 05 用于化学、物理检验的采样 废水实验室 PN-EN ISO 5667-13:2011 z wył. pkt 6.3.3, 6.3.4, 6.3.7, 6.3.8, 6.3.10","test_object_zh":"废物 O)：代码 19 08 05","methodology_zh":"用于化学、物理检验的采样"},{"_id":"6a7f07fd1995264369d8e13f","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Odpady O): kod 19 08 05","methodology":"pH - w H2O","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH - w H2O\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":"Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O): kod 19 08 05 pH - w H2O\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Odpady O): kod 19 08 05 pH - w H2O\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"pH - in H2O","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Waste O): code 19 08 05 pH - in H2O Potentiometric method Wastewater Laboratory Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Waste O): code 19 08 05","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"废物 O)：代码 19 08 05 pH - 于 H2O 中 电位法 废水实验室 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","lab_section_zh":"废水实验室","methodology_zh":"pH - 于 H2O 中","test_object_zh":"废物 O)：代码 19 08 05"},{"_id":"6a7f07fd1995264369d8e140","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Odpady O): kod 19 08 05","methodology":"Zawartość metali","parameters":[{"name":"nikiel","range":"(15,0 – 1000) mg/kg"},{"name":"chrom","range":"(15,0 – 2500) mg/kg"},{"name":"kadm","range":"(5,0 – 1000) mg/kg"},{"name":"cynk","range":"(15,0 – 5000) mg/kg"},{"name":"miedź","range":"(5,0 – 2000) mg/kg"},{"name":"ołów","range":"(15,0 – 1500) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość metali\nZakres:\nnikiel (15,0 – 1000) mg/kg\nchrom (15,0 – 2500) mg/kg\nkadm (5,0 – 1000) mg/kg\ncynk (15,0 – 5000) mg/kg\nmiedź (5,0 – 2000) mg/kg\nołów (15,0 – 1500) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN ISO 54321:2021-07 | PN-ISO 8288:2002 Metoda A","norm_bases":["PN-EN ISO 54321:2021-07","PN-ISO 8288:2002 Metoda A"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":"Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O): kod 19 08 05 Zawartość metali\nZakres:\nnikiel (15,0 – 1000) mg/kg\nchrom (15,0 – 2500) mg/kg\nkadm (5,0 – 1000) mg/kg\ncynk (15,0 – 5000) mg/kg\nmiedź (5,0 – 2000) mg/kg\nołów (15,0 – 1500) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 54321:2021-07 | PN-ISO 8288:2002 Metoda A Odpady O): kod 19 08 05 Zawartosc metali\nZakres:\nnikiel (15,0 – 1000) mg/kg\nchrom (15,0 – 2500) mg/kg\nkadm (5,0 – 1000) mg/kg\ncynk (15,0 – 5000) mg/kg\nmiedz (5,0 – 2000) mg/kg\nolow (15,0 – 1500) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 54321:2021-07 | PN-ISO 8288:2002 Metoda A","categories":["materials","environment"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Metal content","parameters_en":[{"name":"nickel","range":"(15,0 – 1000) mg/kg"},{"name":"chromium","range":"(15,0 – 2500) mg/kg"},{"name":"cadmium","range":"(5,0 – 1000) mg/kg"},{"name":"zinc","range":"(15,0 – 5000) mg/kg"},{"name":"copper","range":"(5,0 – 2000) mg/kg"},{"name":"lead","range":"(15,0 – 1500) mg/kg"}],"search_en":"Waste O): code 19 08 05 Metal content Flame atomic absorption spectrometry (FAAS) Wastewater Laboratory nickel chromium cadmium zinc copper lead PN-EN ISO 54321:2021-07 | PN-ISO 8288:2002 Metoda A","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Waste O): code 19 08 05","parameters_zh":[{"name":"镍","range":"(15,0 – 1000) mg/kg"},{"name":"铬","range":"(15,0 – 2500) mg/kg"},{"name":"镉","range":"(5,0 – 1000) mg/kg"},{"name":"锌","range":"(15,0 – 5000) mg/kg"},{"name":"铜","range":"(5,0 – 2000) mg/kg"},{"name":"铅","range":"(15,0 – 1500) mg/kg"}],"search_zh":"废物 O)：代码 19 08 05 金属含量 火焰原子吸收光谱法（FAAS） 废水实验室 镍 铬 镉 锌 铜 铅 PN-EN ISO 54321:2021-07 | PN-ISO 8288:2002 Metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","methodology_zh":"金属含量","lab_section_zh":"废水实验室","test_object_zh":"废物 O)：代码 19 08 05"},{"_id":"6a7f07fd1995264369d8e141","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Odpady O): kod 19 08 05","methodology":"Zawartość fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,10 – 7,5) %"},{"name":"Zakres","range":"(1000 – 75000) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu ogólnego\nZakres:\nZakres (0,10 – 7,5) %\nZakres (1000 – 75000) mg/kg\nMetoda spektrofotometryczna","reference":"PN-EN ISO 54321:2021-07 | PN-EN ISO 6878:2006 p. 8 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 54321:2021-07","PN-EN ISO 6878:2006 p. 8 +Ap1:2010+Ap2:2010"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":"Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O): kod 19 08 05 Zawartość fosforu ogólnego\nZakres:\nZakres (0,10 – 7,5) %\nZakres (1000 – 75000) mg/kg\nMetoda spektrofotometryczna PN-EN ISO 54321:2021-07 | PN-EN ISO 6878:2006 p. 8 +Ap1:2010+Ap2:2010 Odpady O): kod 19 08 05 Zawartosc fosforu ogolnego\nZakres:\nZakres (0,10 – 7,5) %\nZakres (1000 – 75000) mg/kg\nMetoda spektrofotometryczna PN-EN ISO 54321:2021-07 | PN-EN ISO 6878:2006 p. 8 +Ap1:2010+Ap2:2010","categories":["environment"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Total phosphorus content","parameters_en":[{"name":"Range","range":"(0,10 – 7,5) %"},{"name":"Range","range":"(1000 – 75000) mg/kg"}],"search_en":"Waste O): code 19 08 05 Total phosphorus content Spectrophotometric method Wastewater Laboratory Range Range PN-EN ISO 54321:2021-07 | PN-EN ISO 6878:2006 p. 8 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Waste O): code 19 08 05","parameters_zh":[{"name":"范围","range":"(0,10 – 7,5) %"},{"name":"范围","range":"(1000 – 75000) mg/kg"}],"search_zh":"废物 O)：代码 19 08 05 总磷含量 分光光度法 废水实验室 范围 范围 PN-EN ISO 54321:2021-07 | PN-EN ISO 6878:2006 p. 8 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","methodology_zh":"总磷含量","lab_section_zh":"废水实验室","test_object_zh":"废物 O)：代码 19 08 05"},{"_id":"6a7f07fd1995264369d8e142","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Odpady O): kod 19 08 05","methodology":"Zawartość azotu ogólnego Kjeldahla","parameters":[{"name":"Zakres","range":"(0,10 – 10,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu ogólnego Kjeldahla\nZakres (0,10 – 10,0) %\nMetoda miareczkowa","reference":"PN-EN 13342: 2002-04","norm_bases":["PN-EN 13342: 2002-04"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":"Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O): kod 19 08 05 Zawartość azotu ogólnego Kjeldahla\nZakres (0,10 – 10,0) %\nMetoda miareczkowa PN-EN 13342: 2002-04 Odpady O): kod 19 08 05 Zawartosc azotu ogolnego Kjeldahla\nZakres (0,10 – 10,0) %\nMetoda miareczkowa PN-EN 13342: 2002-04","categories":["environment"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Total Kjeldahl nitrogen content","parameters_en":[{"name":"Range","range":"(0,10 – 10,0) %"}],"search_en":"Waste O): code 19 08 05 Total Kjeldahl nitrogen content Titrimetric method Wastewater Laboratory Range PN-EN 13342: 2002-04","technique_en":"Titrimetric method","test_object_en":"Waste O): code 19 08 05","parameters_zh":[{"name":"范围","range":"(0,10 – 10,0) %"}],"search_zh":"废物 O)：代码 19 08 05 凯氏总氮含量 滴定法 废水实验室 范围 PN-EN 13342: 2002-04","technique_zh":"滴定法","lab_section_zh":"废水实验室","methodology_zh":"凯氏总氮含量","test_object_zh":"废物 O)：代码 19 08 05"},{"_id":"6a7f07fd1995264369d8e143","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Odpady O): kod 19 08 05, 19 08 02","methodology":"Sucha pozostałość","parameters":[{"name":"Zakres","range":"(1,0 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość\nZakres (1,0 – 99,0) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02 metoda A","norm_bases":["PN-EN 15934:2013-02 metoda A"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":"Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O): kod 19 08 05, 19 08 02 Sucha pozostałość\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15934:2013-02 metoda A Odpady O): kod 19 08 05, 19 08 02 Sucha pozostalosc\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15934:2013-02 metoda A","categories":["environment"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Dry residue","parameters_en":[{"name":"Range","range":"(1,0 – 99,0) %"}],"search_en":"Waste O): code 19 08 05, 19 08 02 Dry residue Gravimetric method Wastewater Laboratory Range PN-EN 15934:2013-02 metoda A","technique_en":"Gravimetric method","test_object_en":"Waste O): code 19 08 05, 19 08 02","parameters_zh":[{"name":"范围","range":"(1,0 – 99,0) %"}],"search_zh":"干残渣 重量法 废水实验室 范围 PN-EN 15934:2013-02 metoda A","technique_zh":"重量法","methodology_zh":"干残渣","lab_section_zh":"废水实验室"},{"_id":"6a7f07fd1995264369d8e144","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Odpady O): kod 19 08 05, 19 08 02","methodology":"Straty przy prażeniu suchej masy (LOI) / pozostałość po prażeniu","parameters":[{"name":"Zakres","range":"(0,5 – 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy (LOI) / pozostałość po prażeniu\nZakres (0,5 – 99,5) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Pracownia Ścieków","lab_address":null,"regulatory_area":"Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O): kod 19 08 05, 19 08 02 Straty przy prażeniu suchej masy (LOI) / pozostałość po prażeniu\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 15935:2022-01 Odpady O): kod 19 08 05, 19 08 02 Straty przy prazeniu suchej masy (LOI) / pozostalosc po prazeniu\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["environment"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Laboratory","methodology_en":"Loss on ignition of dry matter (LOI) / residue on ignition","parameters_en":[{"name":"Range","range":"(0,5 – 99,5) %"}],"search_en":"Waste O): code 19 08 05, 19 08 02 Loss on ignition of dry matter (LOI) / residue on ignition Gravimetric method Wastewater Laboratory Range PN-EN 15935:2022-01","technique_en":"Gravimetric method","test_object_en":"Waste O): code 19 08 05, 19 08 02","parameters_zh":[{"name":"范围","range":"(0,5 – 99,5) %"}],"search_zh":"干物质烧失量（LOI）/ 灼烧残渣 重量法 废水实验室 范围 PN-EN 15935:2022-01","technique_zh":"重量法","lab_section_zh":"废水实验室","methodology_zh":"干物质烧失量（LOI）/ 灼烧残渣"},{"_id":"6a7f07fd1995264369d8e145","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Pracownia Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a7f07fd1995264369d8e146","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Temperatura wody/pobranej próbki wody","parameters":[{"name":"Zakres","range":"(0,0 – 30,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura wody/pobranej próbki wody\nZakres (0,0 – 30,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Pracownia Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Temperatura wody/pobranej próbki wody\nZakres (0,0 – 30,0) °C PN-77/C-04584 Woda do spozycia przez ludzi Temperatura wody/pobranej probki wody\nZakres (0,0 – 30,0) °C PN-77/C-04584","categories":["water"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature of water/collected water sample","parameters_en":[{"name":"Range","range":"(0,0 – 30,0) °C"}],"search_en":"Water intended for human consumption Temperature of water/collected water sample Range PN-77/C-04584","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,0 – 30,0) °C"}],"search_zh":"生活饮用水 水/所采水样的温度 范围 PN-77/C-04584","test_object_zh":"生活饮用水","methodology_zh":"水/所采水样的温度"},{"_id":"6a7f07fd1995264369d8e147","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie glinu","parameters":[{"name":"Zakres","range":"(0,04 – 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie glinu\nZakres (0,04 – 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04605/02","norm_bases":["PN-92/C-04605/02"],"lab_section":"Pracownia Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie glinu\nZakres (0,04 – 1,0) mg/l\nMetoda spektrofotometryczna PN-92/C-04605/02 Woda do spozycia przez ludzi Stezenie glinu\nZakres (0,04 – 1,0) mg/l\nMetoda spektrofotometryczna PN-92/C-04605/02","categories":["water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Aluminium concentration","parameters_en":[{"name":"Range","range":"(0,04 – 1,0) mg/l"}],"search_en":"Water intended for human consumption Aluminium concentration Spectrophotometric method Range PN-92/C-04605/02","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,04 – 1,0) mg/l"}],"search_zh":"生活饮用水 铝浓度 分光光度法 范围 PN-92/C-04605/02","technique_zh":"分光光度法","test_object_zh":"生活饮用水","methodology_zh":"铝浓度"},{"_id":"6a7f07fd1995264369d8e148","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,05 – 1,0) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,05 – 1,0) mg/l\nMetoda kolorymetryczna","reference":"PB-01/PW wydanie 2 z dnia 02.01.2020 na podstawie testu kuwetowego Hach nr 21055-28","norm_bases":["PB-01/PW wydanie 2 z dnia 02.01.2020 na podstawie testu kuwetowego Hach nr 21055-28"],"lab_section":"Pracownia Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie chloru wolnego\nZakres (0,05 – 1,0) mg/l\nMetoda kolorymetryczna PB-01/PW wydanie 2 z dnia 02.01.2020 na podstawie testu kuwetowego Hach nr 21055-28 Woda do spozycia przez ludzi Stezenie chloru wolnego\nZakres (0,05 – 1,0) mg/l\nMetoda kolorymetryczna PB-01/PW wydanie 2 z dnia 02.01.2020 na podstawie testu kuwetowego Hach nr 21055-28","categories":["water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,05 – 1,0) mg/l"}],"search_en":"Water intended for human consumption Free chlorine concentration Colorimetric method Range PB-01/PW wydanie 2 z dnia 02.01.2020 na podstawie testu kuwetowego Hach nr 21055-28","technique_en":"Colorimetric method","test_object_en":"Water intended for human consumption","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 1,0) mg/l"}],"search_zh":"生活饮用水 游离氯浓度 比色法 范围 PB-01/PW wydanie 2 z dnia 02.01.2020 na podstawie testu kuwetowego Hach nr 21055-28","technique_zh":"比色法","test_object_zh":"生活饮用水"},{"_id":"6a7f07fd1995264369d8e149","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5; 7.6; 8.2","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5; 7.6; 8.2"],"lab_section":"Pracownia Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5; 7.6; 8.2 Woda Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wylaczeniem pkt. 7.5; 7.6; 8.2","categories":["water"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water Sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5; 7.6; 8.2","test_object_en":"Water","methodology_zh":"化学与物理检测用样品采集","search_zh":"水 化学与物理检测用样品采集 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5; 7.6; 8.2","test_object_zh":"水"},{"_id":"6a7f07fd1995264369d8e14a","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda","methodology":"Temperatura wody/pobranej próbki wody","parameters":[{"name":"Zakres","range":"(0,0 – 30,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura wody/pobranej próbki wody\nZakres (0,0 – 30,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Pracownia Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Temperatura wody/pobranej próbki wody\nZakres (0,0 – 30,0) °C PN-77/C-04584 Woda Temperatura wody/pobranej probki wody\nZakres (0,0 – 30,0) °C PN-77/C-04584","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature of water/collected water sample","parameters_en":[{"name":"Range","range":"(0,0 – 30,0) °C"}],"search_en":"Water Temperature of water/collected water sample Range PN-77/C-04584","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,0 – 30,0) °C"}],"search_zh":"水 水/所采水样的温度 范围 PN-77/C-04584","test_object_zh":"水","methodology_zh":"水/所采水样的温度"},{"_id":"6a7f07fd1995264369d8e14b","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,2 – 40) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,2 – 40) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Pracownia Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Mętność\nZakres (0,2 – 40) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, woda do spozycia przez ludzi Metnosc\nZakres (0,2 – 40) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,2 – 40) NTU"}],"search_en":"Water, water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,2 – 40) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水"},{"_id":"6a7f07fd1995264369d8e14c","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,025 – 4,0) mg/l"},{"name":"Stężenie jonu amonowego","range":"(0,032 – 5,1) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres:\nZakres (0,025 – 4,0) mg/l\nStężenie jonu amonowego (0,032 – 5,1) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotu amonowego\nZakres:\nZakres (0,025 – 4,0) mg/l\nStężenie jonu amonowego (0,032 – 5,1) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, woda do spozycia przez ludzi Stezenie azotu amonowego\nZakres:\nZakres (0,025 – 4,0) mg/l\nStezenie jonu amonowego (0,032 – 5,1) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,025 – 4,0) mg/l"},{"name":"Ammonium ion concentration","range":"(0,032 – 5,1) mg/l"}],"search_en":"Water, water intended for human consumption Ammonium nitrogen concentration Spectrophotometric method Range Ammonium ion concentration PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,025 – 4,0) mg/l"},{"name":"铵离子浓度","range":"(0,032 – 5,1) mg/l"}],"search_zh":"水、生活饮用水 氨氮浓度 分光光度法 范围 铵离子浓度 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f07fd1995264369d8e14d","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,02 – 20,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,02 – 20,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001","norm_bases":["PN-ISO 6332:2001"],"lab_section":"Pracownia Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie żelaza ogólnego\nZakres (0,02 – 20,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 Woda, woda do spozycia przez ludzi Stezenie zelaza ogolnego\nZakres (0,02 – 20,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001","categories":["water"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,02 – 20,0) mg/l"}],"search_en":"Water, water intended for human consumption Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 20,0) mg/l"}],"search_zh":"水、生活饮用水 总铁浓度 分光光度法 范围 PN-ISO 6332:2001","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f07fd1995264369d8e14e","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(10 – 625) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (10 – 625) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Pracownia Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (10 – 625) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (10 – 625) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(10 – 625) mg/l CaCO3"}],"search_en":"Water, water intended for human consumption Total content of calcium and magnesium (total hardness) Titrimetric method Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(10 – 625) mg/l CaCO3"}],"search_zh":"水、生活饮用水 钙与镁总量（总硬度） 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f07fd1995264369d8e14f","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie anionów","parameters":[{"name":"bromiany","range":"(0,004 – 0, 08) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nbromiany (0,004 – 0, 08) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 15061:2003","norm_bases":["PN-EN ISO 15061:2003"],"lab_section":"Pracownia Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie anionów\nbromiany (0,004 – 0, 08) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 15061:2003 Woda, woda do spozycia przez ludzi Stezenie anionow\nbromiany (0,004 – 0, 08) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 15061:2003","categories":["water"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"bromates","range":"(0,004 – 0, 08) mg/l"}],"search_en":"Water, water intended for human consumption Anion concentrations Ion chromatography with conductometric detection (IC-CD) bromates PN-EN ISO 15061:2003","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, water intended for human consumption","methodology_zh":"阴离子浓度","search_zh":"水、生活饮用水 阴离子浓度 离子色谱-电导检测法（IC-CD） PN-EN ISO 15061:2003","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、生活饮用水"},{"_id":"6a7f07fd1995264369d8e150","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie anionów","parameters":[{"name":"chloryny","range":"(0,05 – 1,0) mg/l"},{"name":"chlorany","range":"(0,1 – 2,0) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nchloryny (0,05 – 1,0) mg/l\nchlorany (0,1 – 2,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-4:2022-08","norm_bases":["PN-EN ISO 10304-4:2022-08"],"lab_section":"Pracownia Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie anionów\nZakres:\nchloryny (0,05 – 1,0) mg/l\nchlorany (0,1 – 2,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-4:2022-08 Woda, woda do spozycia przez ludzi Stezenie anionow\nZakres:\nchloryny (0,05 – 1,0) mg/l\nchlorany (0,1 – 2,0) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-4:2022-08","categories":["water"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"chlorites","range":"(0,05 – 1,0) mg/l"},{"name":"chlorates","range":"(0,1 – 2,0) mg/l"}],"search_en":"Water, water intended for human consumption Anion concentrations Ion chromatography with conductometric detection (IC-CD) chlorites chlorates PN-EN ISO 10304-4:2022-08","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, water intended for human consumption","methodology_zh":"阴离子浓度","search_zh":"水、生活饮用水 阴离子浓度 离子色谱-电导检测法（IC-CD） 亚氯酸盐 氯酸盐 PN-EN ISO 10304-4:2022-08","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、生活饮用水","parameters_zh":[{"name":"亚氯酸盐","range":"(0,05 – 1,0) mg/l"},{"name":"氯酸盐","range":"(0,1 – 2,0) mg/l"}]},{"_id":"6a7f07fd1995264369d8e151","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Suma chloranów i chlorynów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma chloranów i chlorynów (z obliczeń)","reference":"PN-EN ISO 10304-4:2022-08","norm_bases":["PN-EN ISO 10304-4:2022-08"],"lab_section":"Pracownia Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Suma chloranów i chlorynów (z obliczeń) PN-EN ISO 10304-4:2022-08 Woda, woda do spozycia przez ludzi Suma chloranow i chlorynow (z obliczen) PN-EN ISO 10304-4:2022-08","categories":["water"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of chlorates and chlorites (calculated)","search_en":"Water, water intended for human consumption Sum of chlorates and chlorites (calculated) PN-EN ISO 10304-4:2022-08","test_object_en":"Water, water intended for human consumption","search_zh":"水、生活饮用水 氯酸盐与亚氯酸盐总量（由计算得出） PN-EN ISO 10304-4:2022-08","test_object_zh":"水、生活饮用水","methodology_zh":"氯酸盐与亚氯酸盐总量（由计算得出）"},{"_id":"6a7f07fd1995264369d8e152","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie anionów","parameters":[{"name":"chlorki","range":"(2,5 – 250) mg/l"},{"name":"fluorki","range":"(0,1 – 2) mg/l"},{"name":"azotany","range":"(2,5 – 50) mg/l"},{"name":"azotyny","range":"(0,05 – 1) mg/l"},{"name":"siarczany","range":"(5 – 250) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nchlorki (2,5 – 250) mg/l\nfluorki (0,1 – 2) mg/l\nazotany (2,5 – 50) mg/l\nazotyny (0,05 – 1) mg/l\nsiarczany (5 – 250) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009 + AC:2012","norm_bases":["PN-EN ISO 10304-1:2009 + AC:2012"],"lab_section":"Pracownia Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie anionów\nZakres:\nchlorki (2,5 – 250) mg/l\nfluorki (0,1 – 2) mg/l\nazotany (2,5 – 50) mg/l\nazotyny (0,05 – 1) mg/l\nsiarczany (5 – 250) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 + AC:2012 Woda, woda do spozycia przez ludzi Stezenie anionow\nZakres:\nchlorki (2,5 – 250) mg/l\nfluorki (0,1 – 2) mg/l\nazotany (2,5 – 50) mg/l\nazotyny (0,05 – 1) mg/l\nsiarczany (5 – 250) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009 + AC:2012","categories":["water"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"chlorides","range":"(2,5 – 250) mg/l"},{"name":"fluorides","range":"(0,1 – 2) mg/l"},{"name":"nitrates","range":"(2,5 – 50) mg/l"},{"name":"nitrites","range":"(0,05 – 1) mg/l"},{"name":"sulfates","range":"(5 – 250) mg/l"}],"search_en":"Water, water intended for human consumption Anion concentrations Ion chromatography with conductometric detection (IC-CD) chlorides fluorides nitrates nitrites sulfates PN-EN ISO 10304-1:2009 + AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, water intended for human consumption","methodology_zh":"阴离子浓度","search_zh":"水、生活饮用水 阴离子浓度 离子色谱-电导检测法（IC-CD） 氯化物 氟化物 硝酸盐 亚硝酸盐 硫酸盐 PN-EN ISO 10304-1:2009 + AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、生活饮用水","parameters_zh":[{"name":"氯化物","range":"(2,5 – 250) mg/l"},{"name":"氟化物","range":"(0,1 – 2) mg/l"},{"name":"硝酸盐","range":"(2,5 – 50) mg/l"},{"name":"亚硝酸盐","range":"(0,05 – 1) mg/l"},{"name":"硫酸盐","range":"(5 – 250) mg/l"}]},{"_id":"6a7f07fd1995264369d8e153","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, woda do spozycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Water, water intended for human consumption pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"水、生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f07fd1995264369d8e154","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(100 – 3000) µS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (100 – 3000) µS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Pracownia Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (100 – 3000) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (100 – 3000) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(100 – 3000) µS/cm"}],"search_en":"Water, water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(100 – 3000) µS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f07fd1995264369d8e155","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,015 – 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (0,015 – 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04590/03","norm_bases":["PN-92/C-04590/03"],"lab_section":"Pracownia Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie manganu\nZakres (0,015 – 1,0) mg/l\nMetoda spektrofotometryczna PN-92/C-04590/03 Woda, woda do spozycia przez ludzi Stezenie manganu\nZakres (0,015 – 1,0) mg/l\nMetoda spektrofotometryczna PN-92/C-04590/03","categories":["water"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(0,015 – 1,0) mg/l"}],"search_en":"Water, water intended for human consumption Manganese concentration Spectrophotometric method Range PN-92/C-04590/03","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,015 – 1,0) mg/l"}],"search_zh":"水、生活饮用水 锰浓度 分光光度法 范围 PN-92/C-04590/03","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f07fd1995264369d8e156","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,05 – 20,0) mg/l"},{"name":"Nasycenie tlenem","range":"(1 – 200) %"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres:\nZakres (0,05 – 20,0) mg/l\nNasycenie tlenem (1 – 200) %\nMetoda optyczna","reference":"ISO 17289:2014","norm_bases":["ISO 17289:2014"],"lab_section":"Pracownia Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie tlenu rozpuszczonego\nZakres:\nZakres (0,05 – 20,0) mg/l\nNasycenie tlenem (1 – 200) %\nMetoda optyczna ISO 17289:2014 Woda, woda do spozycia przez ludzi Stezenie tlenu rozpuszczonego\nZakres:\nZakres (0,05 – 20,0) mg/l\nNasycenie tlenem (1 – 200) %\nMetoda optyczna ISO 17289:2014","categories":["water"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(0,05 – 20,0) mg/l"},{"name":"Oxygen saturation","range":"(1 – 200) %"}],"search_en":"Water, water intended for human consumption Dissolved oxygen concentration Optical method Range Oxygen saturation ISO 17289:2014","technique_en":"Optical method","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,05 – 20,0) mg/l"},{"name":"氧饱和度","range":"(1 – 200) %"}],"search_zh":"水、生活饮用水 溶解氧浓度 光学法 范围 氧饱和度 ISO 17289:2014","technique_zh":"光学法","test_object_zh":"水、生活饮用水","methodology_zh":"溶解氧浓度"},{"_id":"6a7f07fd1995264369d8e157","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5 – 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5 – 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Pracownia Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie chlorków\nZakres (5 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, woda do spozycia przez ludzi Stezenie chlorkow\nZakres (5 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5 – 400) mg/l"}],"search_en":"Water, water intended for human consumption Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 – 400) mg/l"}],"search_zh":"水、生活饮用水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f07fd1995264369d8e158","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10 – 500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10 – 500) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Pracownia Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie siarczanów\nZakres (10 – 500) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, woda do spozycia przez ludzi Stezenie siarczanow\nZakres (10 – 500) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10 – 500) mg/l"}],"search_en":"Water, water intended for human consumption Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 – 500) mg/l"}],"search_zh":"水、生活饮用水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f07fd1995264369d8e159","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Zasadowość ogólna","parameters":[{"name":"Zakres","range":"(0,5 – 10) mmol/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zasadowość ogólna\nZakres (0,5 – 10) mmol/l\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001 +Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001 +Ap1:2004"],"lab_section":"Pracownia Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Zasadowość ogólna\nZakres (0,5 – 10) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001 +Ap1:2004 Woda, woda do spozycia przez ludzi Zasadowosc ogolna\nZakres (0,5 – 10) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001 +Ap1:2004","categories":["water"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total alkalinity","parameters_en":[{"name":"Range","range":"(0,5 – 10) mmol/l"}],"search_en":"Water, water intended for human consumption Total alkalinity Titrimetric method Range PN-EN ISO 9963-1:2001 +Ap1:2004","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,5 – 10) mmol/l"}],"search_zh":"水、生活饮用水 总碱度 滴定法 范围 PN-EN ISO 9963-1:2001 +Ap1:2004","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","methodology_zh":"总碱度"},{"_id":"6a7f07fd1995264369d8e15a","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,44 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,44 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04576-08:1982","norm_bases":["PN-C-04576-08:1982"],"lab_section":"Pracownia Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotanów\nZakres (0,44 – 100) mg/l\nMetoda spektrofotometryczna PN-C-04576-08:1982 Woda, woda do spozycia przez ludzi Stezenie azotanow\nZakres (0,44 – 100) mg/l\nMetoda spektrofotometryczna PN-C-04576-08:1982","categories":["water"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(0,44 – 100) mg/l"}],"search_en":"Water, water intended for human consumption Nitrate concentration Spectrophotometric method Range PN-C-04576-08:1982","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,44 – 100) mg/l"}],"search_zh":"水、生活饮用水 硝酸盐浓度 分光光度法 范围 PN-C-04576-08:1982","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f07fd1995264369d8e15b","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,04 – 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,04 – 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,04 – 1,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,04 – 1,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,04 – 1,0) mg/l"}],"search_en":"Water, water intended for human consumption Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 1,0) mg/l"}],"search_zh":"水、生活饮用水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a7f07fd1995264369d8e15c","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":"Pracownia Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory","methodology_en":"Sampling for microbiological testing","search_en":"Water intended for human consumption Sampling for microbiological testing Microbiology Laboratory PN-EN ISO 19458:2007","test_object_en":"Water intended for human consumption","lab_section_zh":"微生物室","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 微生物室 PN-EN ISO 19458:2007","test_object_zh":"生活饮用水"},{"_id":"6a7f07fd1995264369d8e15d","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda","methodology":"Ogólna liczba mikroorganizmów w 22⁰C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 22⁰C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222: 2004","norm_bases":["PN-EN ISO 6222: 2004"],"lab_section":"Pracownia Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Ogólna liczba mikroorganizmów w 22⁰C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222: 2004 Woda Ogolna liczba mikroorganizmow w 22⁰C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222: 2004","categories":["water"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory","search_en":"Water Plate method (pour plate) Microbiology Laboratory PN-EN ISO 6222: 2004","technique_en":"Plate method (pour plate)","test_object_en":"Water","lab_section_zh":"微生物室","search_zh":"水 平板法（倾注培养） 微生物室 PN-EN ISO 6222: 2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水"},{"_id":"6a7f07fd1995264369d8e15e","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda","methodology":"Ogólna liczba mikroorganizmów w 36⁰C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 36⁰C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222: 2004","norm_bases":["PN-EN ISO 6222: 2004"],"lab_section":"Pracownia Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Ogólna liczba mikroorganizmów w 36⁰C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222: 2004 Woda Ogolna liczba mikroorganizmow w 36⁰C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222: 2004","categories":["water"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory","search_en":"Water Plate method (pour plate) Microbiology Laboratory PN-EN ISO 6222: 2004","technique_en":"Plate method (pour plate)","test_object_en":"Water","lab_section_zh":"微生物室","search_zh":"水 平板法（倾注培养） 微生物室 PN-EN ISO 6222: 2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水"},{"_id":"6a7f07fd1995264369d8e15f","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Pracownia Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory","methodology_en":"Intestinal enterococci count","search_en":"Water Intestinal enterococci count Membrane filtration method Microbiology Laboratory PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water","lab_section_zh":"微生物室","methodology_zh":"粪肠球菌计数","search_zh":"水 粪肠球菌计数 膜过滤法 微生物室 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水"},{"_id":"6a7f07fd1995264369d8e160","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda","methodology":"Liczba Clostridium perfringens (łącznie z przetrwalnikami)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Clostridium perfringens (łącznie z przetrwalnikami)\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":"Pracownia Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba Clostridium perfringens (łącznie z przetrwalnikami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda Liczba Clostridium perfringens (lacznie z przetrwalnikami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory","methodology_en":"Clostridium perfringens count (including spores)","search_en":"Water Clostridium perfringens count (including spores) Membrane filtration method Microbiology Laboratory PN-EN ISO 14189:2016-10","technique_en":"Membrane filtration method","test_object_en":"Water","lab_section_zh":"微生物室","search_zh":"水 产气荚膜梭菌数（含芽孢） 膜过滤法 微生物室 PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","test_object_zh":"水","methodology_zh":"产气荚膜梭菌数（含芽孢）"},{"_id":"6a7f07fd1995264369d8e161","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda","methodology":"Liczba bakterii grupy coli i Escherichia coli","parameters":[],"technique":"Metoda NPL (test Colilert)","techniques":["Metoda NPL (test Colilert)"],"computed":[],"activity":"Liczba bakterii grupy coli i Escherichia coli\nMetoda NPL (test Colilert)","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Pracownia Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba bakterii grupy coli i Escherichia coli\nMetoda NPL (test Colilert) PN-EN ISO 9308-2:2014-06 Woda Liczba bakterii grupy coli i Escherichia coli\nMetoda NPL (test Colilert) PN-EN ISO 9308-2:2014-06","categories":["microbiology","water"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory","methodology_en":"Coliform bacteria and Escherichia coli count","search_en":"Water Coliform bacteria and Escherichia coli count MPN method (Colilert test) Microbiology Laboratory PN-EN ISO 9308-2:2014-06","technique_en":"MPN method (Colilert test)","test_object_en":"Water","lab_section_zh":"微生物室","search_zh":"水 大肠菌群数与大肠埃希氏菌数 MPN 法（Colilert 测试） 微生物室 PN-EN ISO 9308-2:2014-06","test_object_zh":"水","methodology_zh":"大肠菌群数与大肠埃希氏菌数","technique_zh":"MPN 法（Colilert 测试）"},{"_id":"6a7f07fd1995264369d8e162","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Pracownia Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory","methodology_en":"Coliform bacteria count","search_en":"Water Coliform bacteria count Membrane filtration method Microbiology Laboratory PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water","lab_section_zh":"微生物室","methodology_zh":"大肠菌群计数","search_zh":"水 大肠菌群计数 膜过滤法 微生物室 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水"},{"_id":"6a7f07fd1995264369d8e163","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda","methodology":"Liczba bakterii Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Pracownia Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["microbiology","water"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory","methodology_en":"Escherichia coli count","search_en":"Water Escherichia coli count Membrane filtration method Microbiology Laboratory PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water","lab_section_zh":"微生物室","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 微生物室 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水"},{"_id":"6a7f07fd1995264369d8e164","lab_id":"69ad52a3de79e566650fb53c","country":"PL","accr_number":"AB 1036","accr_body":"PCA","test_object":"Woda","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"Pracownia Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory","methodology_en":"Pseudomonas aeruginosa count","search_en":"Water Pseudomonas aeruginosa count Membrane filtration method Microbiology Laboratory PN-EN ISO 16266:2009","technique_en":"Membrane filtration method","test_object_en":"Water","lab_section_zh":"微生物室","methodology_zh":"铜绿假单胞菌计数","search_zh":"水 铜绿假单胞菌计数 膜过滤法 微生物室 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"水"}],"has_pdf":true}