{"lab":{"_id":"69ad52a3de79e566650fb52a","accr_number":"AB 1026","country":"PL","accr_body":"PCA","address":"ul. Warzywna 3, 95-200 Pabianice, DZIAŁ OCHRONY ŚRODOWISKA - LABORATORIUM, ul. 15 P.P. „Wilków” 12","categories":["water"],"city":"Pabianice","imported_at":"2026-03-08T10:42:43.265Z","methods_count":37,"name":"ZAKŁAD WODOCIĄGÓW I KANALIZACJI Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1026.pdf"],"scope_summary":"","search_text":"zakład wodociągów i kanalizacji sp. z o.o. ul. warzywna 3, 95-200 pabianice, dział ochrony środowiska - laboratorium, ul. 15 p.p. „wilków” 12 water other pharma electronics","status":"active","updated_at":"2026-03-08T14:50:12.111Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:12.111Z","parse_date":"2026-07-17T16:19:14.040Z","parse_source":"m5-mistral-qa","email_confidence":"high","email_mx":true,"email_source":"https://zwik.pabianice.pl/kontakt/","fields_of_testing":[{"codes":"C/28/P, C/29/P, C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of water, drinking water, sewage"},{"codes":"N/28/P, N/29/P, N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of water, drinking water, sewage"}],"issue":{"no":"20","date":"26.01.2026"},"map_coord":[51.668397,19.326041],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":37},"category_scores":{"water":37},"has_zh":true},"methods":[{"_id":"6a5a56029af9f73f382540a2","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem 7.5 i 7.6","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem 7.5 i 7.6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wyłączeniem 7.5 i 7.6 Woda Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wylaczeniem 7.5 i 7.6","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 z wyłączeniem 7.5 i 7.6","methodology_zh":"化学与物理检测用样品采集","search_zh":"水 化学与物理检测用样品采集 PN-EN ISO 5667-6:2016-12 z wyłączeniem 7.5 i 7.6","test_object_zh":"水"},{"_id":"6a5a56029af9f73f382540a3","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a5a56029af9f73f382540a4","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Barwa Zakres: (5 − 70) mg/l Pt Metoda spektrofotometryczna","methodology_en":"Colour Range: (5 − 70) mg/l Pt Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Barwa Zakres: (5 − 70) mg/l Pt Metoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Barwa Zakres: (5 − 70) mg/l Pt Metoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06 Woda, woda do spozycia przez ludzi Barwa Zakres: (5 − 70) mg/l Pt Metoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Colour Range: (5 − 70) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","search_zh":"水、生活饮用水 PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","test_object_zh":"水、生活饮用水"},{"_id":"6a5a56029af9f73f382540a5","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie chlorków Zakres: (2,0 − 500) mg/l Metoda miareczkowa","methodology_en":"Chloride concentration Range: (2,0 − 500) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (2,0 − 500) mg/l Metoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie chlorków Zakres: (2,0 − 500) mg/l Metoda miareczkowa PN-ISO 9297:1994 Woda, woda do spozycia przez ludzi Stezenie chlorkow Zakres: (2,0 − 500) mg/l Metoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Chloride concentration Range: (2,0 − 500) mg/l Titrimetric method PN-ISO 9297:1994","search_zh":"水、生活饮用水 PN-ISO 9297:1994","test_object_zh":"水、生活饮用水"},{"_id":"6a5a56029af9f73f382540a6","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie chloru wolnego Zakres: (0,02 − 0,6) mg/l Metoda spektrofotometryczna","methodology_en":"Free chlorine concentration Range: (0,02 − 0,6) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chloru wolnego Zakres: (0,02 − 0,6) mg/l Metoda spektrofotometryczna","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie chloru wolnego Zakres: (0,02 − 0,6) mg/l Metoda spektrofotometryczna PN-EN ISO 7393-2:2018-04 Woda, woda do spozycia przez ludzi Stezenie chloru wolnego Zakres: (0,02 − 0,6) mg/l Metoda spektrofotometryczna PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Free chlorine concentration Range: (0,02 − 0,6) mg/l Spectrophotometric method PN-EN ISO 7393-2:2018-04","search_zh":"水、生活饮用水 PN-EN ISO 7393-2:2018-04","test_object_zh":"水、生活饮用水"},{"_id":"6a5a56029af9f73f382540a7","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie manganu Zakres: (0,015 − 1,0) mg/l Metoda spektrofotometryczna","methodology_en":"Manganese concentration Range: (0,015 − 1,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie manganu Zakres: (0,015 − 1,0) mg/l Metoda spektrofotometryczna","reference":"PB-19 wydanie 02 z dnia 22.01.2018 r.","norm_bases":["PB-19 wydanie 02 z dnia 22.01.2018 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie manganu Zakres: (0,015 − 1,0) mg/l Metoda spektrofotometryczna PB-19 wydanie 02 z dnia 22.01.2018 r. Woda, woda do spozycia przez ludzi Stezenie manganu Zakres: (0,015 − 1,0) mg/l Metoda spektrofotometryczna PB-19 wydanie 02 z dnia 22.01.2018 r.","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Manganese concentration Range: (0,015 − 1,0) mg/l Spectrophotometric method PB-19 wydanie 02 z dnia 22.01.2018 r.","search_zh":"水、生活饮用水 PB-19 wydanie 02 z dnia 22.01.2018 r.","test_object_zh":"水、生活饮用水"},{"_id":"6a5a56029af9f73f382540a8","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Twardość ogólna Zakres: (0,05 – 10,0) mmol/l (5,0 – 1000) mg/l CaCO 3 Metoda miareczkowa","methodology_en":"Total hardness Range: (0,05 – 10,0) mmol/l (5,0 – 1000) mg/l CaCO 3 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Twardość ogólna Zakres: (0,05 – 10,0) mmol/l (5,0 – 1000) mg/l CaCO 3 Metoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Twardość ogólna Zakres: (0,05 – 10,0) mmol/l (5,0 – 1000) mg/l CaCO 3 Metoda miareczkowa PN-ISO 6059:1999 Woda, woda do spozycia przez ludzi Twardosc ogolna Zakres: (0,05 – 10,0) mmol/l (5,0 – 1000) mg/l CaCO 3 Metoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Total hardness Range: (0,05 – 10,0) mmol/l (5,0 – 1000) mg/l CaCO 3 Titrimetric method PN-ISO 6059:1999","search_zh":"水、生活饮用水 PN-ISO 6059:1999","test_object_zh":"水、生活饮用水"},{"_id":"6a5a56029af9f73f382540a9","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie wapnia Zakres: (0,05 – 7,50) mmol/l (2,0 – 300) mg/l Metoda miareczkowa","methodology_en":"Calcium concentration Range: (0,05 – 7,50) mmol/l (2,0 – 300) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie wapnia Zakres: (0,05 – 7,50) mmol/l (2,0 – 300) mg/l Metoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie wapnia Zakres: (0,05 – 7,50) mmol/l (2,0 – 300) mg/l Metoda miareczkowa PN-ISO 6058:1999 Woda, woda do spozycia przez ludzi Stezenie wapnia Zakres: (0,05 – 7,50) mmol/l (2,0 – 300) mg/l Metoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Calcium concentration Range: (0,05 – 7,50) mmol/l (2,0 – 300) mg/l Titrimetric method PN-ISO 6058:1999","search_zh":"水、生活饮用水 PN-ISO 6058:1999","test_object_zh":"水、生活饮用水"},{"_id":"6a5a56029af9f73f382540aa","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie magnezu (z obliczeń)","methodology_en":"Magnesium concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie magnezu (z obliczeń)","reference":"PN-C-04554-4:1999 Zał. A","norm_bases":["PN-C-04554-4:1999 Zał. A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie magnezu (z obliczeń) PN-C-04554-4:1999 Zał. A Woda, woda do spozycia przez ludzi Stezenie magnezu (z obliczen) PN-C-04554-4:1999 Zal. A","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Magnesium concentration (calculated) PN-C-04554-4:1999 Zał. A","search_zh":"水、生活饮用水 镁浓度（计算值） PN-C-04554-4:1999 Zał. A","test_object_zh":"水、生活饮用水","methodology_zh":"镁浓度（计算值）"},{"_id":"6a5a56029af9f73f382540ab","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie glinu Zakres: (0,050 – 1,00) mg/l Metoda spektrofotometryczna","methodology_en":"Aluminium concentration Range: (0,050 – 1,00) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie glinu Zakres: (0,050 – 1,00) mg/l Metoda spektrofotometryczna","reference":"PB-21 wydanie 02 z dnia 04.11.2019 r. na podstawie testu HACH LCK 301","norm_bases":["PB-21 wydanie 02 z dnia 04.11.2019 r. na podstawie testu HACH LCK 301"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie glinu Zakres: (0,050 – 1,00) mg/l Metoda spektrofotometryczna PB-21 wydanie 02 z dnia 04.11.2019 r. na podstawie testu HACH LCK 301 Woda, woda do spozycia przez ludzi Stezenie glinu Zakres: (0,050 – 1,00) mg/l Metoda spektrofotometryczna PB-21 wydanie 02 z dnia 04.11.2019 r. na podstawie testu HACH LCK 301","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Aluminium concentration Range: (0,050 – 1,00) mg/l Spectrophotometric method PB-21 wydanie 02 z dnia 04.11.2019 r. na podstawie testu HACH LCK 301","search_zh":"水、生活饮用水 PB-21 wydanie 02 z dnia 04.11.2019 r. na podstawie testu HACH LCK 301","test_object_zh":"水、生活饮用水"},{"_id":"6a5a56029af9f73f382540ac","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Indeks nadmanganianowy Zakres: (0,50 – 10) mg/l O 2 Metoda miareczkowa","methodology_en":"Permanganate index Range: (0,50 – 10) mg/l O 2 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy Zakres: (0,50 – 10) mg/l O 2 Metoda miareczkowa","reference":"EN ISO 8467:2001","norm_bases":["EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Indeks nadmanganianowy Zakres: (0,50 – 10) mg/l O 2 Metoda miareczkowa EN ISO 8467:2001 Woda, woda do spozycia przez ludzi Indeks nadmanganianowy Zakres: (0,50 – 10) mg/l O 2 Metoda miareczkowa EN ISO 8467:2001","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Permanganate index Range: (0,50 – 10) mg/l O 2 Titrimetric method EN ISO 8467:2001","search_zh":"水、生活饮用水 高锰酸盐指数 范围：(0,50 – 10) mg/l O2 滴定法 EN ISO 8467:2001","test_object_zh":"水、生活饮用水","methodology_zh":"高锰酸盐指数 范围：(0,50 – 10) mg/l O2 滴定法"},{"_id":"6a5a56029af9f73f382540ad","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda, ścieki, woda do spożycia przez ludzi","test_object_en":"Water, wastewater, water intended for human consumption","methodology":"Stężenie azotu amonowego Zakres: (0,050 – 1,00) mg/l Metoda spektrofotometryczna","methodology_en":"Ammonium nitrogen concentration Range: (0,050 – 1,00) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego Zakres: (0,050 – 1,00) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki, woda do spożycia przez ludzi Stężenie azotu amonowego Zakres: (0,050 – 1,00) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, scieki, woda do spozycia przez ludzi Stezenie azotu amonowego Zakres: (0,050 – 1,00) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater, water intended for human consumption Ammonium nitrogen concentration Range: (0,050 – 1,00) mg/l Spectrophotometric method PN-ISO 7150-1:2002","search_zh":"水、废水、生活饮用水 PN-ISO 7150-1:2002","test_object_zh":"水、废水、生活饮用水"},{"_id":"6a5a56029af9f73f382540ae","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda, ścieki, woda do spożycia przez ludzi","test_object_en":"Water, wastewater, water intended for human consumption","methodology":"Stężenie azotu azotanowego Zakres: (0,23 – 22,6) mg/l Stężenie azotanów Zakres: (1,00 – 100) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrate nitrogen concentration Range: (0,23 – 22,6) mg/l Nitrate concentration Range: (1,00 – 100) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego Zakres: (0,23 – 22,6) mg/l Stężenie azotanów Zakres: (1,00 – 100) mg/l Metoda spektrofotometryczna","reference":"PB-22 wydanie 01 z dnia 28.05.2020 r. na podstawie testu HACH LCK 339","norm_bases":["PB-22 wydanie 01 z dnia 28.05.2020 r. na podstawie testu HACH LCK 339"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki, woda do spożycia przez ludzi Stężenie azotu azotanowego Zakres: (0,23 – 22,6) mg/l Stężenie azotanów Zakres: (1,00 – 100) mg/l Metoda spektrofotometryczna PB-22 wydanie 01 z dnia 28.05.2020 r. na podstawie testu HACH LCK 339 Woda, scieki, woda do spozycia przez ludzi Stezenie azotu azotanowego Zakres: (0,23 – 22,6) mg/l Stezenie azotanow Zakres: (1,00 – 100) mg/l Metoda spektrofotometryczna PB-22 wydanie 01 z dnia 28.05.2020 r. na podstawie testu HACH LCK 339","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater, water intended for human consumption Nitrate nitrogen concentration Range: (0,23 – 22,6) mg/l Nitrate concentration Range: (1,00 – 100) mg/l Spectrophotometric method PB-22 wydanie 01 z dnia 28.05.2020 r. na podstawie testu HACH LCK 339","search_zh":"水、废水、生活饮用水 PB-22 wydanie 01 z dnia 28.05.2020 r. na podstawie testu HACH LCK 339","test_object_zh":"水、废水、生活饮用水"},{"_id":"6a5a56029af9f73f382540af","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda, ścieki, woda do spożycia przez ludzi","test_object_en":"Water, wastewater, water intended for human consumption","methodology":"Stężenia azotu azotynowego Zakres: (0,02 − 0,30) mg/l Stężenia azotynów Zakres: (0,07− 1,00) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrite nitrogen concentrations Range: (0,02 − 0,30) mg/l Nitrite concentrations Range: (0,07− 1,00) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenia azotu azotynowego Zakres: (0,02 − 0,30) mg/l Stężenia azotynów Zakres: (0,07− 1,00) mg/l Metoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki, woda do spożycia przez ludzi Stężenia azotu azotynowego Zakres: (0,02 − 0,30) mg/l Stężenia azotynów Zakres: (0,07− 1,00) mg/l Metoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki, woda do spozycia przez ludzi Stezenia azotu azotynowego Zakres: (0,02 − 0,30) mg/l Stezenia azotynow Zakres: (0,07− 1,00) mg/l Metoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater, water intended for human consumption Nitrite nitrogen concentrations Range: (0,02 − 0,30) mg/l Nitrite concentrations Range: (0,07− 1,00) mg/l Spectrophotometric method PN-EN 26777:1999","search_zh":"水、废水、生活饮用水 PN-EN 26777:1999","test_object_zh":"水、废水、生活饮用水"},{"_id":"6a5a56029af9f73f382540b0","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda, ścieki, woda do spożycia przez ludzi","test_object_en":"Water, wastewater, water intended for human consumption","methodology":"pH Zakres: 2,0 – 12,0 Metoda potencjometryczna","methodology_en":"pH Range: 2,0 – 12,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 2,0 – 12,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki, woda do spożycia przez ludzi pH Zakres: 2,0 – 12,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki, woda do spozycia przez ludzi pH Zakres: 2,0 – 12,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater, water intended for human consumption pH Range: 2,0 – 12,0 Potentiometric method PN-EN ISO 10523:2012","methodology_zh":"pH 范围：2,0 – 12,0 电位法","search_zh":"水、废水、生活饮用水 pH 范围：2,0 – 12,0 电位法 PN-EN ISO 10523:2012","test_object_zh":"水、废水、生活饮用水"},{"_id":"6a5a56029af9f73f382540b1","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda, ścieki, woda do spożycia przez ludzi","test_object_en":"Water, wastewater, water intended for human consumption","methodology":"Przewodność elektryczna właściwa Zakres: (0,100 − 10,0) mS/cm Metoda konduktometryczna","methodology_en":"Electrical conductivity Range: (0,100 − 10,0) mS/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (0,100 − 10,0) mS/cm Metoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki, woda do spożycia przez ludzi Przewodność elektryczna właściwa Zakres: (0,100 − 10,0) mS/cm Metoda konduktometryczna PN-EN 27888:1999 Woda, scieki, woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa Zakres: (0,100 − 10,0) mS/cm Metoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater, water intended for human consumption Electrical conductivity Range: (0,100 − 10,0) mS/cm Conductometric method PN-EN 27888:1999","search_zh":"水、废水、生活饮用水 PN-EN 27888:1999","test_object_zh":"水、废水、生活饮用水"},{"_id":"6a5a56029af9f73f382540b2","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda, ścieki, woda do spożycia przez ludzi","test_object_en":"Water, wastewater, water intended for human consumption","methodology":"Stężenie siarczanów Zakres: (2,0 – 250) mg/l Metoda turbidymetryczna","methodology_en":"Sulphate concentration Range: (2,0 – 250) mg/l Turbidimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie siarczanów Zakres: (2,0 – 250) mg/l Metoda turbidymetryczna","reference":"PN-79/C-04566.10","norm_bases":["PN-79/C-04566.10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki, woda do spożycia przez ludzi Stężenie siarczanów Zakres: (2,0 – 250) mg/l Metoda turbidymetryczna PN-79/C-04566.10 Woda, scieki, woda do spozycia przez ludzi Stezenie siarczanow Zakres: (2,0 – 250) mg/l Metoda turbidymetryczna PN-79/C-04566.10","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater, water intended for human consumption Sulphate concentration Range: (2,0 – 250) mg/l Turbidimetric method PN-79/C-04566.10","search_zh":"水、废水、生活饮用水 PN-79/C-04566.10","test_object_zh":"水、废水、生活饮用水"},{"_id":"6a5a56029af9f73f382540b3","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda, ścieki, woda do spożycia przez ludzi","test_object_en":"Water, wastewater, water intended for human consumption","methodology":"Stężenie siarczanów Zakres: (10 – 1000) mg/l Metoda wagowa","methodology_en":"Sulphate concentration Range: (10 – 1000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie siarczanów Zakres: (10 – 1000) mg/l Metoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki, woda do spożycia przez ludzi Stężenie siarczanów Zakres: (10 – 1000) mg/l Metoda wagowa PN-ISO 9280:2002 Woda, scieki, woda do spozycia przez ludzi Stezenie siarczanow Zakres: (10 – 1000) mg/l Metoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater, water intended for human consumption Sulphate concentration Range: (10 – 1000) mg/l Gravimetric method PN-ISO 9280:2002","search_zh":"水、废水、生活饮用水 硫酸盐浓度 范围：(10 – 1000) mg/l 重量法 PN-ISO 9280:2002","test_object_zh":"水、废水、生活饮用水","methodology_zh":"硫酸盐浓度 范围：(10 – 1000) mg/l 重量法"},{"_id":"6a5a56029af9f73f382540b4","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda, ścieki, woda do spożycia przez ludzi","test_object_en":"Water, wastewater, water intended for human consumption","methodology":"Stężenie żelaza ogólnego Zakres: (0,020 − 15,0) mg/l Metoda spektrofotometryczna","methodology_en":"Total iron concentration Range: (0,020 − 15,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego Zakres: (0,020 − 15,0) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki, woda do spożycia przez ludzi Stężenie żelaza ogólnego Zakres: (0,020 − 15,0) mg/l Metoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda, scieki, woda do spozycia przez ludzi Stezenie zelaza ogolnego Zakres: (0,020 − 15,0) mg/l Metoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater, water intended for human consumption Total iron concentration Range: (0,020 − 15,0) mg/l Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06","search_zh":"水、废水、生活饮用水 PN-ISO 6332:2001+Ap1:2016-06","test_object_zh":"水、废水、生活饮用水"},{"_id":"6a5a56029af9f73f382540b5","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-05 wydanie 05 z dnia 22.08.2022 r.","norm_bases":["PB-05 wydanie 05 z dnia 22.08.2022 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu ogólnego (z obliczeń) PB-05 wydanie 05 z dnia 22.08.2022 r. Woda, scieki Stezenie azotu ogolnego (z obliczen) PB-05 wydanie 05 z dnia 22.08.2022 r.","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Total nitrogen concentration (calculated) PB-05 wydanie 05 z dnia 22.08.2022 r.","methodology_zh":"总氮浓度（计算值）","search_zh":"水、废水 总氮浓度（计算值） PB-05 wydanie 05 z dnia 22.08.2022 r.","test_object_zh":"水、废水"},{"_id":"6a5a56029af9f73f382540b6","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu amonowego Zakres: (0,5 − 1000) mg/l Metoda miareczkowa","methodology_en":"Ammonium nitrogen concentration Range: (0,5 − 1000) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego Zakres: (0,5 − 1000) mg/l Metoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu amonowego Zakres: (0,5 − 1000) mg/l Metoda miareczkowa PN-ISO 5664:2002 Woda, scieki Stezenie azotu amonowego Zakres: (0,5 − 1000) mg/l Metoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Ammonium nitrogen concentration Range: (0,5 − 1000) mg/l Titrimetric method PN-ISO 5664:2002","search_zh":"水、废水 PN-ISO 5664:2002","test_object_zh":"水、废水"},{"_id":"6a5a56029af9f73f382540b7","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu Kjeldahla Zakres: (1,0 − 1000) mg/l Metoda miareczkowa","methodology_en":"Kjeldahl nitrogen concentration Range: (1,0 − 1000) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla Zakres: (1,0 − 1000) mg/l Metoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla Zakres: (1,0 − 1000) mg/l Metoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla Zakres: (1,0 − 1000) mg/l Metoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Kjeldahl nitrogen concentration Range: (1,0 − 1000) mg/l Titrimetric method PN-EN 25663:2001","search_zh":"水、废水 PN-EN 25663:2001","test_object_zh":"水、废水"},{"_id":"6a5a56029af9f73f382540b8","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu – BZT 5 Zakres: (3 − 6000) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand – BOD 5 Range: (3 − 6000) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu – BZT 5 Zakres: (3 − 6000) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu – BZT 5 Zakres: (3 − 6000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu – BZT 5 Zakres: (3 − 6000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Biochemical oxygen demand – BOD 5 Range: (3 − 6000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12","search_zh":"水、废水 PN-EN ISO 5815-1:2019-12","test_object_zh":"水、废水"},{"_id":"6a5a56029af9f73f382540b9","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu – BZT , 5 Zakres: (0,50 − 6,0) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand – BOD , 5 Range: (0,50 − 6,0) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu – BZT , 5 Zakres: (0,50 − 6,0) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu – BZT , 5 Zakres: (0,50 − 6,0) mg/l O 2 Metoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu – BZT , 5 Zakres: (0,50 − 6,0) mg/l O 2 Metoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Biochemical oxygen demand – BOD , 5 Range: (0,50 − 6,0) mg/l O 2 Electrochemical method PN-EN 1899-2:2002","search_zh":"水、废水 PN-EN 1899-2:2002","test_object_zh":"水、废水"},{"_id":"6a5a56029af9f73f382540ba","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie tlenu rozpuszczonego Zakres: (0,5 – 11,0) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Dissolved oxygen concentration Range: (0,5 – 11,0) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenu rozpuszczonego Zakres: (0,5 – 11,0) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN ISO 5814:2013-04","norm_bases":["PN-EN ISO 5814:2013-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie tlenu rozpuszczonego Zakres: (0,5 – 11,0) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5814:2013-04 Woda, scieki Stezenie tlenu rozpuszczonego Zakres: (0,5 – 11,0) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5814:2013-04","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Dissolved oxygen concentration Range: (0,5 – 11,0) mg/l O 2 Electrochemical method PN-EN ISO 5814:2013-04","search_zh":"水、废水 PN-EN ISO 5814:2013-04","test_object_zh":"水、废水"},{"_id":"6a5a56029af9f73f382540bb","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Chemiczne zapotrzebowanie tlenu – ChZT Zakres: (6,0 − 10000) mg/l O 2 Metoda spektrofotometryczna","methodology_en":"Chemical oxygen demand – COD Range: (6,0 − 10000) mg/l O 2 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu – ChZT Zakres: (6,0 − 10000) mg/l O 2 Metoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu – ChZT Zakres: (6,0 − 10000) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu – ChZT Zakres: (6,0 − 10000) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Chemical oxygen demand – COD Range: (6,0 − 10000) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005","search_zh":"水、废水 PN-ISO 15705:2005","test_object_zh":"水、废水"},{"_id":"6a5a56029af9f73f382540bc","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie fosforu ogólnego Zakres: (0,06 − 30,0) mg/l (0,18 − 90,0) mg/l PO 3- 4 Metoda spektrofotometryczna","methodology_en":"Total phosphorus concentration Range: (0,06 − 30,0) mg/l (0,18 − 90,0) mg/l PO 3- 4 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego Zakres: (0,06 − 30,0) mg/l (0,18 − 90,0) mg/l PO 3- 4 Metoda spektrofotometryczna","reference":"PB-10 wydanie 03 z dnia 07.11.2019 r. na podstawie testu HACH LCK 349","norm_bases":["PB-10 wydanie 03 z dnia 07.11.2019 r. na podstawie testu HACH LCK 349"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie fosforu ogólnego Zakres: (0,06 − 30,0) mg/l (0,18 − 90,0) mg/l PO 3- 4 Metoda spektrofotometryczna PB-10 wydanie 03 z dnia 07.11.2019 r. na podstawie testu HACH LCK 349 Woda, scieki Stezenie fosforu ogolnego Zakres: (0,06 − 30,0) mg/l (0,18 − 90,0) mg/l PO 3- 4 Metoda spektrofotometryczna PB-10 wydanie 03 z dnia 07.11.2019 r. na podstawie testu HACH LCK 349","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Total phosphorus concentration Range: (0,06 − 30,0) mg/l (0,18 − 90,0) mg/l PO 3- 4 Spectrophotometric method PB-10 wydanie 03 z dnia 07.11.2019 r. na podstawie testu HACH LCK 349","search_zh":"水、废水 PB-10 wydanie 03 z dnia 07.11.2019 r. na podstawie testu HACH LCK 349","test_object_zh":"水、废水"},{"_id":"6a5a56029af9f73f382540bd","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie ortofosforanów Zakres: (0,18 − 90,0) mg/l Metoda spektrofotometryczna","methodology_en":"Orthophosphate concentration Range: (0,18 − 90,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie ortofosforanów Zakres: (0,18 − 90,0) mg/l Metoda spektrofotometryczna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie ortofosforanów Zakres: (0,18 − 90,0) mg/l Metoda spektrofotometryczna Woda, scieki Stezenie ortofosforanow Zakres: (0,18 − 90,0) mg/l Metoda spektrofotometryczna","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Orthophosphate concentration Range: (0,18 − 90,0) mg/l Spectrophotometric method","search_zh":"水、废水","test_object_zh":"水、废水"},{"_id":"6a5a56029af9f73f382540be","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie fosforu ogólnego Zakres: (0,060 − 30,0) mg/l (0,18 − 90,0) mg/l PO 3- 4 Metoda spektrofotometryczna","methodology_en":"Total phosphorus concentration Range: (0,060 − 30,0) mg/l (0,18 − 90,0) mg/l PO 3- 4 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego Zakres: (0,060 − 30,0) mg/l (0,18 − 90,0) mg/l PO 3- 4 Metoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie fosforu ogólnego Zakres: (0,060 − 30,0) mg/l (0,18 − 90,0) mg/l PO 3- 4 Metoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 Woda, scieki Stezenie fosforu ogolnego Zakres: (0,060 − 30,0) mg/l (0,18 − 90,0) mg/l PO 3- 4 Metoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","categories":["water"],"row_index":28,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Total phosphorus concentration Range: (0,060 − 30,0) mg/l (0,18 − 90,0) mg/l PO 3- 4 Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","search_zh":"水、废水 PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","test_object_zh":"水、废水"},{"_id":"6a5a56029af9f73f382540bf","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie miedzi Zakres: (0,05 − 1,20) mg/l Metoda spektrofotometryczna","methodology_en":"Copper concentration Range: (0,05 − 1,20) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie miedzi Zakres: (0,05 − 1,20) mg/l Metoda spektrofotometryczna","reference":"PB-13 wydanie 02 z dnia 07.11.2019 r. na podstawie testu HACH LCK 529","norm_bases":["PB-13 wydanie 02 z dnia 07.11.2019 r. na podstawie testu HACH LCK 529"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie miedzi Zakres: (0,05 − 1,20) mg/l Metoda spektrofotometryczna PB-13 wydanie 02 z dnia 07.11.2019 r. na podstawie testu HACH LCK 529 Woda, scieki Stezenie miedzi Zakres: (0,05 − 1,20) mg/l Metoda spektrofotometryczna PB-13 wydanie 02 z dnia 07.11.2019 r. na podstawie testu HACH LCK 529","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Copper concentration Range: (0,05 − 1,20) mg/l Spectrophotometric method PB-13 wydanie 02 z dnia 07.11.2019 r. na podstawie testu HACH LCK 529","search_zh":"水、废水 PB-13 wydanie 02 z dnia 07.11.2019 r. na podstawie testu HACH LCK 529","test_object_zh":"水、废水"},{"_id":"6a5a56029af9f73f382540c0","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie cynku Zakres: (0,2 − 7,2) mg/l Metoda spektrofotometryczna","methodology_en":"Zinc concentration Range: (0,2 − 7,2) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie cynku Zakres: (0,2 − 7,2) mg/l Metoda spektrofotometryczna","reference":"PB-14 wydanie 02 z dnia 07.11.2019 r. na podstawie testu HACH LCK 360","norm_bases":["PB-14 wydanie 02 z dnia 07.11.2019 r. na podstawie testu HACH LCK 360"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie cynku Zakres: (0,2 − 7,2) mg/l Metoda spektrofotometryczna PB-14 wydanie 02 z dnia 07.11.2019 r. na podstawie testu HACH LCK 360 Woda, scieki Stezenie cynku Zakres: (0,2 − 7,2) mg/l Metoda spektrofotometryczna PB-14 wydanie 02 z dnia 07.11.2019 r. na podstawie testu HACH LCK 360","categories":["water"],"row_index":30,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Zinc concentration Range: (0,2 − 7,2) mg/l Spectrophotometric method PB-14 wydanie 02 z dnia 07.11.2019 r. na podstawie testu HACH LCK 360","search_zh":"水、废水 PB-14 wydanie 02 z dnia 07.11.2019 r. na podstawie testu HACH LCK 360","test_object_zh":"水、废水"},{"_id":"6a5a56029af9f73f382540c1","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie chromu ogólnego Zakres: (0,05 − 1,00) mg/l Metoda spektrofotometryczna","methodology_en":"Total chromium concentration Range: (0,05 − 1,00) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chromu ogólnego Zakres: (0,05 − 1,00) mg/l Metoda spektrofotometryczna","reference":"PB-11 wydanie 02 z dnia 07.11.2019 r. na podstawie testu HACH LCK 313","norm_bases":["PB-11 wydanie 02 z dnia 07.11.2019 r. na podstawie testu HACH LCK 313"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie chromu ogólnego Zakres: (0,05 − 1,00) mg/l Metoda spektrofotometryczna PB-11 wydanie 02 z dnia 07.11.2019 r. na podstawie testu HACH LCK 313 Woda, scieki Stezenie chromu ogolnego Zakres: (0,05 − 1,00) mg/l Metoda spektrofotometryczna PB-11 wydanie 02 z dnia 07.11.2019 r. na podstawie testu HACH LCK 313","categories":["water"],"row_index":31,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Total chromium concentration Range: (0,05 − 1,00) mg/l Spectrophotometric method PB-11 wydanie 02 z dnia 07.11.2019 r. na podstawie testu HACH LCK 313","search_zh":"水、废水 PB-11 wydanie 02 z dnia 07.11.2019 r. na podstawie testu HACH LCK 313","test_object_zh":"水、废水"},{"_id":"6a5a56029af9f73f382540c2","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie niklu Zakres: (0,05 − 1,00) mg/l Metoda spektrofotometryczna","methodology_en":"Nickel concentration Range: (0,05 − 1,00) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie niklu Zakres: (0,05 − 1,00) mg/l Metoda spektrofotometryczna","reference":"PB-12 wydanie 02 z dnia 07.11.2019 r. na podstawie testu HACH LCK 537","norm_bases":["PB-12 wydanie 02 z dnia 07.11.2019 r. na podstawie testu HACH LCK 537"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie niklu Zakres: (0,05 − 1,00) mg/l Metoda spektrofotometryczna PB-12 wydanie 02 z dnia 07.11.2019 r. na podstawie testu HACH LCK 537 Woda, scieki Stezenie niklu Zakres: (0,05 − 1,00) mg/l Metoda spektrofotometryczna PB-12 wydanie 02 z dnia 07.11.2019 r. na podstawie testu HACH LCK 537","categories":["water"],"row_index":32,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Nickel concentration Range: (0,05 − 1,00) mg/l Spectrophotometric method PB-12 wydanie 02 z dnia 07.11.2019 r. na podstawie testu HACH LCK 537","search_zh":"水、废水 PB-12 wydanie 02 z dnia 07.11.2019 r. na podstawie testu HACH LCK 537","test_object_zh":"水、废水"},{"_id":"6a5a56029af9f73f382540c3","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Woda, ścieki, wody opadowe, wody roztopowe","test_object_en":"Water, wastewater, rainwater, snowmelt water","methodology":"Zawiesiny ogólne Zakres: (2,0 − 1000) mg/l Metoda wagowa","methodology_en":"Total suspended solids (TSS) Range: (2,0 − 1000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: (2,0 − 1000) mg/l Metoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki, wody opadowe, wody roztopowe Zawiesiny ogólne Zakres: (2,0 − 1000) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki, wody opadowe, wody roztopowe Zawiesiny ogolne Zakres: (2,0 − 1000) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":33,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater, rainwater, snowmelt water Total suspended solids (TSS) Range: (2,0 − 1000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物 范围：(2,0 − 1000) mg/l 重量法","search_zh":"水、废水、雨水、融雪水 总悬浮物 范围：(2,0 − 1000) mg/l 重量法 PN-EN 872:2007+Ap1:2007","test_object_zh":"水、废水、雨水、融雪水"},{"_id":"6a5a56029af9f73f382540c4","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Wody opadowe, wody roztopowe","test_object_en":"Rainwater, snowmelt water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna","methodology_en":"Sampling for chemical and physical testing Manual method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wody opadowe, wody roztopowe Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna PN-ISO 5667-10:2021-11 Wody opadowe, wody roztopowe Pobieranie probek do badan chemicznych i fizycznych Metoda manualna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":34,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rainwater, snowmelt water Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11","search_zh":"雨水、融雪水 用于化学与物理检验的采样 手工法 PN-ISO 5667-10:2021-11","test_object_zh":"雨水、融雪水","methodology_zh":"用于化学与物理检验的采样 手工法"},{"_id":"6a5a56029af9f73f382540c5","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna i automatyczna","methodology_en":"Sampling for chemical and physical testing Manual and automatic method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna i automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna i automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych Metoda manualna i automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":35,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Sampling for chemical and physical testing Manual and automatic method PN-ISO 5667-10:2021-11","search_zh":"污水 用于化学与物理检验的采样 手工与自动法 PN-ISO 5667-10:2021-11","test_object_zh":"污水","methodology_zh":"用于化学与物理检验的采样 手工与自动法"},{"_id":"6a5a56029af9f73f382540c6","lab_id":"69ad52a3de79e566650fb52a","country":"PL","accr_number":"AB 1026","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie chlorków Zakres: (5,0 − 1000) mg/l Metoda miareczkowa","methodology_en":"Chloride concentration Range: (5,0 − 1000) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (5,0 − 1000) mg/l Metoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie chlorków Zakres: (5,0 − 1000) mg/l Metoda miareczkowa PN-ISO 9297:1994 Scieki Stezenie chlorkow Zakres: (5,0 − 1000) mg/l Metoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":36,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Chloride concentration Range: (5,0 − 1000) mg/l Titrimetric method PN-ISO 9297:1994","search_zh":"污水 PN-ISO 9297:1994","test_object_zh":"污水"}],"has_pdf":true}