{"lab":{"_id":"69ad52a3de79e566650fb524","accr_number":"AB 1023","country":"PL","accr_body":"PCA","address":"„EKO-POMIAR” ANDRZEJ KOJDER, LABORATORIUM BADAWCZE, ul. Olbrachta 182, 35-614 Rzeszów","categories":["water"],"city":"Rzeszów","imported_at":"2026-03-08T10:42:43.265Z","methods_count":9,"name":"ZESPÓŁ USŁUG EKOLOGICZNYCH","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1023.pdf"],"scope_summary":"","search_text":"zespół usług ekologicznych „eko-pomiar” andrzej kojder, laboratorium badawcze, ul. olbrachta 182, 35-614 rzeszów water other environment pharma electronics","status":"active","updated_at":"2026-03-08T14:50:11.874Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:11.874Z","parse_date":"2026-07-17T16:19:13.943Z","parse_source":"m5-mistral-qa","email_confidence":"high","email_mx":true,"email_source":"https://ekopomiar.rzeszow.pl/kontakt/","fields_of_testing":[{"codes":"C/28/P; C/30/P; C/32/P","pl":"Badania chemiczne i pobieranie próbek wody, ścieków, odpadów","en":"Chemical tests and sampling of water, sewage, waste"},{"codes":"N/28/P; N/30/P; N/31/P; N/32/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, ścieków, gleby, osadów, odpadów","en":"Tests of physical properties and sampling of water, sewage, soil, sediments, waste"},{"codes":"P/32","pl":"Pobieranie próbek osadów, odpadów","en":"Sampling of sediments, waste"}],"issue":{"no":"20","date":"26.03.2025"},"map_coord":[50.032017,22.066259],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":9},"category_scores":{"water":9},"has_zh":true},"methods":[{"_id":"6a5a56019af9f73f3825404b","lab_id":"69ad52a3de79e566650fb524","country":"PL","accr_number":"AB 1023","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Przewodność elektryczna właściwa Zakres: (80 – 5000) µS/cm Metoda konduktometryczna","methodology_en":"Electrical conductivity Range: (80 – 5000) µS/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (80 – 5000) µS/cm Metoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Przewodność elektryczna właściwa Zakres: (80 – 5000) µS/cm Metoda konduktometryczna PN-EN 27888:1999 Woda Scieki Przewodnosc elektryczna wlasciwa Zakres: (80 – 5000) µS/cm Metoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Electrical conductivity Range: (80 – 5000) µS/cm Conductometric method PN-EN 27888:1999","search_zh":"水 废水 PN-EN 27888:1999","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f3825404c","lab_id":"69ad52a3de79e566650fb524","country":"PL","accr_number":"AB 1023","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"pH Zakres: 4,0 – 12,0 Metoda potencjometryczna","methodology_en":"pH Range: 4,0 – 12,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 4,0 – 12,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki pH Zakres: 4,0 – 12,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Woda Scieki pH Zakres: 4,0 – 12,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater pH Range: 4,0 – 12,0 Potentiometric method PN-EN ISO 10523:2012","search_zh":"水 废水 pH 范围：4,0 – 12,0 电位法 PN-EN ISO 10523:2012","test_object_zh":"水 废水","methodology_zh":"pH 范围：4,0 – 12,0 电位法"},{"_id":"6a5a56019af9f73f3825404d","lab_id":"69ad52a3de79e566650fb524","country":"PL","accr_number":"AB 1023","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu azotanowego Zakres: (0,10 – 30) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrate nitrogen concentration Range: (0,10 – 30) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego Zakres: (0,10 – 30) mg/l Metoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu azotanowego Zakres: (0,10 – 30) mg/l Metoda spektrofotometryczna PN-82/C-04576/08 Woda Scieki Stezenie azotu azotanowego Zakres: (0,10 – 30) mg/l Metoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Nitrate nitrogen concentration Range: (0,10 – 30) mg/l Spectrophotometric method PN-82/C-04576/08","search_zh":"水 废水 PN-82/C-04576/08","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f3825404e","lab_id":"69ad52a3de79e566650fb524","country":"PL","accr_number":"AB 1023","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu azotynowego Zakres: (0,010 – 25) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrite nitrogen concentration Range: (0,010 – 25) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego Zakres: (0,010 – 25) mg/l Metoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu azotynowego Zakres: (0,010 – 25) mg/l Metoda spektrofotometryczna PN-EN 26777:1999 Woda Scieki Stezenie azotu azotynowego Zakres: (0,010 – 25) mg/l Metoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Nitrite nitrogen concentration Range: (0,010 – 25) mg/l Spectrophotometric method PN-EN 26777:1999","search_zh":"水 废水 PN-EN 26777:1999","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f3825404f","lab_id":"69ad52a3de79e566650fb524","country":"PL","accr_number":"AB 1023","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu amonowego Zakres: (0,040 – 25) mg/l Metoda spektrofotometryczna","methodology_en":"Ammonium nitrogen concentration Range: (0,040 – 25) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego Zakres: (0,040 – 25) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu amonowego Zakres: (0,040 – 25) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002 Woda Scieki Stezenie azotu amonowego Zakres: (0,040 – 25) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Ammonium nitrogen concentration Range: (0,040 – 25) mg/l Spectrophotometric method PN-ISO 7150-1:2002","search_zh":"水 废水 PN-ISO 7150-1:2002","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38254050","lab_id":"69ad52a3de79e566650fb524","country":"PL","accr_number":"AB 1023","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu Kjeldahla Zakres: (0,50 – 50) mg/l Metoda spektrofotometryczna","methodology_en":"Kjeldahl nitrogen concentration Range: (0,50 – 50) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla Zakres: (0,50 – 50) mg/l Metoda spektrofotometryczna","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu Kjeldahla Zakres: (0,50 – 50) mg/l Metoda spektrofotometryczna PN-EN 25663:2001 Woda Scieki Stezenie azotu Kjeldahla Zakres: (0,50 – 50) mg/l Metoda spektrofotometryczna PN-EN 25663:2001","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Kjeldahl nitrogen concentration Range: (0,50 – 50) mg/l Spectrophotometric method PN-EN 25663:2001","search_zh":"水 废水 PN-EN 25663:2001","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38254051","lab_id":"69ad52a3de79e566650fb524","country":"PL","accr_number":"AB 1023","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576.14","norm_bases":["PN-73/C-04576.14"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576.14 Woda Scieki Stezenie azotu ogolnego (z obliczen) PN-73/C-04576.14","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Total nitrogen concentration (calculated) PN-73/C-04576.14","methodology_zh":"总氮浓度（计算值）","search_zh":"水 废水 总氮浓度（计算值） PN-73/C-04576.14","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38254052","lab_id":"69ad52a3de79e566650fb524","country":"PL","accr_number":"AB 1023","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie chlorków Zakres: (5,0 – 4000) mg/l Metoda miareczkowa","methodology_en":"Chloride concentration Range: (5,0 – 4000) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (5,0 – 4000) mg/l Metoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie chlorków Zakres: (5,0 – 4000) mg/l Metoda miareczkowa PN-ISO 9297:1994 Woda Scieki Stezenie chlorkow Zakres: (5,0 – 4000) mg/l Metoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Chloride concentration Range: (5,0 – 4000) mg/l Titrimetric method PN-ISO 9297:1994","search_zh":"水 废水 氯化物浓度 范围：(5,0 – 4000) mg/l 滴定法 PN-ISO 9297:1994","test_object_zh":"水 废水","methodology_zh":"氯化物浓度 范围：(5,0 – 4000) mg/l 滴定法"},{"_id":"6a5a56019af9f73f38254053","lab_id":"69ad52a3de79e566650fb524","country":"PL","accr_number":"AB 1023","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie żelaza ogólnego Zakres: (0,10 – 20) mg/l Metoda spektrofotometryczna","methodology_en":"Total iron concentration Range: (0,10 – 20) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego Zakres: (0,10 – 20) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie żelaza ogólnego Zakres: (0,10 – 20) mg/l Metoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda Scieki Stezenie zelaza ogolnego Zakres: (0,10 – 20) mg/l Metoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Total iron concentration Range: (0,10 – 20) mg/l Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06","search_zh":"水 废水 PN-ISO 6332:2001+Ap1:2016-06","test_object_zh":"水 废水"}],"has_pdf":true}