{"lab":{"_id":"69ad52a3de79e566650fb512","accr_number":"AB 1007","country":"PL","accr_body":"PCA","address":"ul. Stara Droga 85, 97-500 Radomsko, LABORATORIUM DZIAŁU OCHRONY ŚRODOWISKA, ul. Spacerowa 120","categories":["water"],"city":"Radomsko","imported_at":"2026-03-08T10:42:43.265Z","methods_count":25,"name":"PRZEDSIĘBIORSTWO GOSPODARKI KOMUNALNEJ Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1007.pdf"],"scope_summary":"","search_text":"przedsiębiorstwo gospodarki komunalnej sp. z o.o. ul. stara droga 85, 97-500 radomsko, laboratorium działu ochrony środowiska, ul. spacerowa 120 water other pharma electronics","status":"active","updated_at":"2026-03-08T14:50:11.238Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:11.238Z","parse_date":"2026-07-17T16:19:13.685Z","parse_source":"m5-mistral-qa","email_confidence":"high","email_mx":true,"email_source":"http://www.pgk-radomsko.pl/kontakt-lab","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of water, drinking water, sewage"},{"codes":"N/28/P; N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of water, drinking water, sewage"},{"codes":"P/29","pl":"Pobieranie próbek wody do spożycia przez ludzi","en":"Sampling of drinking water"}],"issue":{"no":"17","date":"24.01.2025"},"map_coord":[51.055558,19.436918],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":25,"microbiology":1},"category_scores":{"water":24.04,"microbiology":0.04},"has_zh":true},"methods":[{"_id":"6a5a56019af9f73f38253f80","lab_id":"69ad52a3de79e566650fb512","country":"PL","accr_number":"AB 1007","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura ścieków / pobranej próbki ścieków Zakres: (0,5 – 70,0) °C","methodology_en":"Sampling for chemical and physical testing Manual method Automatic method Temperature of wastewater / of the wastewater sample taken Range: (0,5 – 70,0) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura ścieków / pobranej próbki ścieków Zakres: (0,5 – 70,0) °C","reference":"PN-ISO 5667-10:2021-11 PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11 PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura ścieków / pobranej próbki ścieków Zakres: (0,5 – 70,0) °C PN-ISO 5667-10:2021-11 PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura sciekow / pobranej probki sciekow Zakres: (0,5 – 70,0) °C PN-ISO 5667-10:2021-11 PN-77/C-04584","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Sampling for chemical and physical testing Manual method Automatic method Temperature of wastewater / of the wastewater sample taken Range: (0,5 – 70,0) °C PN-ISO 5667-10:2021-11 PN-77/C-04584","search_zh":"污水 PN-ISO 5667-10:2021-11 PN-77/C-04584","test_object_zh":"污水"},{"_id":"6a5a56019af9f73f38253f81","lab_id":"69ad52a3de79e566650fb512","country":"PL","accr_number":"AB 1007","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody / pobranej próbki wody Zakres: (0,5 – 70,0) °C","methodology_en":"Sampling for chemical and physical testing Temperature of water / collected water sample Range: (0,5 – 70,0) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody / pobranej próbki wody Zakres: (0,5 – 70,0) °C","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5 | PN-77/C-04584","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody / pobranej próbki wody Zakres: (0,5 – 70,0) °C PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5 | PN-77/C-04584 Woda Pobieranie probek do badan chemicznych i fizycznych Temperatura wody / pobranej probki wody Zakres: (0,5 – 70,0) °C PN-EN ISO 5667-6:2016-12 z wylaczeniem pkt. 7.5 | PN-77/C-04584","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Sampling for chemical and physical testing Temperature of water / collected water sample Range: (0,5 – 70,0) °C PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5 | PN-77/C-04584","search_zh":"水 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5 | PN-77/C-04584","test_object_zh":"水"},{"_id":"6a5a56019af9f73f38253f82","lab_id":"69ad52a3de79e566650fb512","country":"PL","accr_number":"AB 1007","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody / pobranej próbki wody Zakres: (0,5 – 70,0) °C","methodology_en":"Sampling for chemical and physical testing Temperature of water / collected water sample Range: (0,5 – 70,0) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody / pobranej próbki wody Zakres: (0,5 – 70,0) °C","reference":"PN-ISO 5667-5:2017-10 PN-77/C-04584","norm_bases":["PN-ISO 5667-5:2017-10 PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody / pobranej próbki wody Zakres: (0,5 – 70,0) °C PN-ISO 5667-5:2017-10 PN-77/C-04584 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych Temperatura wody / pobranej probki wody Zakres: (0,5 – 70,0) °C PN-ISO 5667-5:2017-10 PN-77/C-04584","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Sampling for chemical and physical testing Temperature of water / collected water sample Range: (0,5 – 70,0) °C PN-ISO 5667-5:2017-10 PN-77/C-04584","search_zh":"生活饮用水 PN-ISO 5667-5:2017-10 PN-77/C-04584","test_object_zh":"生活饮用水"},{"_id":"6a5a56019af9f73f38253f83","lab_id":"69ad52a3de79e566650fb512","country":"PL","accr_number":"AB 1007","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem pkt. 4.4.3","categories":["water","microbiology"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3","test_object_zh":"生活饮用水"},{"_id":"6a5a56019af9f73f38253f84","lab_id":"69ad52a3de79e566650fb512","country":"PL","accr_number":"AB 1007","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie chloru wolnego Zakres: (0,08 – 1,00) mg/l Metoda spektrofotometryczna","methodology_en":"Free chlorine concentration Range: (0,08 – 1,00) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chloru wolnego Zakres: (0,08 – 1,00) mg/l Metoda spektrofotometryczna","reference":"PN-EN ISO 7393-2:2018-04 z wyłączeniem pkt. 9.5","norm_bases":["PN-EN ISO 7393-2:2018-04 z wyłączeniem pkt. 9.5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie chloru wolnego Zakres: (0,08 – 1,00) mg/l Metoda spektrofotometryczna PN-EN ISO 7393-2:2018-04 z wyłączeniem pkt. 9.5 Woda do spozycia przez ludzi Stezenie chloru wolnego Zakres: (0,08 – 1,00) mg/l Metoda spektrofotometryczna PN-EN ISO 7393-2:2018-04 z wylaczeniem pkt. 9.5","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Free chlorine concentration Range: (0,08 – 1,00) mg/l Spectrophotometric method PN-EN ISO 7393-2:2018-04 z wyłączeniem pkt. 9.5","search_zh":"生活饮用水 PN-EN ISO 7393-2:2018-04 z wyłączeniem pkt. 9.5","test_object_zh":"生活饮用水"},{"_id":"6a5a56019af9f73f38253f85","lab_id":"69ad52a3de79e566650fb512","country":"PL","accr_number":"AB 1007","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie jonu amonowego Zakres: (0,064 – 386) mg/l Metoda spektrofotometryczna","methodology_en":"Ammonium ion concentration Range: (0,064 – 386) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego Zakres: (0,064 – 386) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie jonu amonowego Zakres: (0,064 – 386) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002 Woda do spozycia przez ludzi Stezenie jonu amonowego Zakres: (0,064 – 386) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Ammonium ion concentration Range: (0,064 – 386) mg/l Spectrophotometric method PN-ISO 7150-1:2002","search_zh":"生活饮用水 PN-ISO 7150-1:2002","test_object_zh":"生活饮用水"},{"_id":"6a5a56019af9f73f38253f86","lab_id":"69ad52a3de79e566650fb512","country":"PL","accr_number":"AB 1007","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Indeks nadmanganianowy Zakres: (1,0 – 10,0) mg/l O 2 Metoda miareczkowa","methodology_en":"Permanganate index Range: (1,0 – 10,0) mg/l O 2 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy Zakres: (1,0 – 10,0) mg/l O 2 Metoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Indeks nadmanganianowy Zakres: (1,0 – 10,0) mg/l O 2 Metoda miareczkowa PN-EN ISO 8467:2001 Woda do spozycia przez ludzi Indeks nadmanganianowy Zakres: (1,0 – 10,0) mg/l O 2 Metoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Permanganate index Range: (1,0 – 10,0) mg/l O 2 Titrimetric method PN-EN ISO 8467:2001","search_zh":"生活饮用水 PN-EN ISO 8467:2001","test_object_zh":"生活饮用水"},{"_id":"6a5a56019af9f73f38253f87","lab_id":"69ad52a3de79e566650fb512","country":"PL","accr_number":"AB 1007","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie azotanów Zakres: (0,20 – 100) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrate concentration Range: (0,20 – 100) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotanów Zakres: (0,20 – 100) mg/l Metoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie azotanów Zakres: (0,20 – 100) mg/l Metoda spektrofotometryczna PN-82/C-04576/08 Woda do spozycia przez ludzi Stezenie azotanow Zakres: (0,20 – 100) mg/l Metoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Nitrate concentration Range: (0,20 – 100) mg/l Spectrophotometric method PN-82/C-04576/08","search_zh":"生活饮用水 PN-82/C-04576/08","test_object_zh":"生活饮用水"},{"_id":"6a5a56019af9f73f38253f88","lab_id":"69ad52a3de79e566650fb512","country":"PL","accr_number":"AB 1007","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie azotynów Zakres: (0,030 – 20,0) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrite concentration Range: (0,030 – 20,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotynów Zakres: (0,030 – 20,0) mg/l Metoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie azotynów Zakres: (0,030 – 20,0) mg/l Metoda spektrofotometryczna PN-EN 26777:1999 Woda do spozycia przez ludzi Stezenie azotynow Zakres: (0,030 – 20,0) mg/l Metoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Nitrite concentration Range: (0,030 – 20,0) mg/l Spectrophotometric method PN-EN 26777:1999","search_zh":"生活饮用水 PN-EN 26777:1999","test_object_zh":"生活饮用水"},{"_id":"6a5a56019af9f73f38253f89","lab_id":"69ad52a3de79e566650fb512","country":"PL","accr_number":"AB 1007","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Mętność Zakres: (0,50 – 20) NTU Metoda nefelometryczna","methodology_en":"Turbidity Range: (0,50 – 20) NTU Nephelometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Mętność Zakres: (0,50 – 20) NTU Metoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Mętność Zakres: (0,50 – 20) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda do spozycia przez ludzi Metnosc Zakres: (0,50 – 20) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Turbidity Range: (0,50 – 20) NTU Nephelometric method PN-EN ISO 7027-1:2016-09","search_zh":"生活饮用水 PN-EN ISO 7027-1:2016-09","test_object_zh":"生活饮用水"},{"_id":"6a5a56019af9f73f38253f8a","lab_id":"69ad52a3de79e566650fb512","country":"PL","accr_number":"AB 1007","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (18 – 500) mg/l CaCO 3 Metoda miareczkowa","methodology_en":"Total calcium and magnesium content (total hardness) Range: (18 – 500) mg/l CaCO 3 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (18 – 500) mg/l CaCO 3 Metoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (18 – 500) mg/l CaCO 3 Metoda miareczkowa PN-ISO 6059:1999 Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna) Zakres: (18 – 500) mg/l CaCO 3 Metoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Total calcium and magnesium content (total hardness) Range: (18 – 500) mg/l CaCO 3 Titrimetric method PN-ISO 6059:1999","search_zh":"生活饮用水 PN-ISO 6059:1999","test_object_zh":"生活饮用水"},{"_id":"6a5a56019af9f73f38253f8b","lab_id":"69ad52a3de79e566650fb512","country":"PL","accr_number":"AB 1007","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Barwa Zakres: (5 – 40) mg/l Pt Metoda wizualna","methodology_en":"Colour Range: (5 – 40) mg/l Pt Visual method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Barwa Zakres: (5 – 40) mg/l Pt Metoda wizualna","reference":"PN-EN ISO 7887:2012+Ap1:2015 Metoda D","norm_bases":["PN-EN ISO 7887:2012+Ap1:2015 Metoda D"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Barwa Zakres: (5 – 40) mg/l Pt Metoda wizualna PN-EN ISO 7887:2012+Ap1:2015 Metoda D Woda do spozycia przez ludzi Barwa Zakres: (5 – 40) mg/l Pt Metoda wizualna PN-EN ISO 7887:2012+Ap1:2015 Metoda D","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Colour Range: (5 – 40) mg/l Pt Visual method PN-EN ISO 7887:2012+Ap1:2015 Metoda D","search_zh":"生活饮用水 PN-EN ISO 7887:2012+Ap1:2015 Metoda D","test_object_zh":"生活饮用水"},{"_id":"6a5a56019af9f73f38253f8c","lab_id":"69ad52a3de79e566650fb512","country":"PL","accr_number":"AB 1007","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1 – 3000) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD 5 Range: (1 – 3000) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1 – 3000) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1 – 3000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda Scieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1 – 3000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Biochemical oxygen demand - BOD 5 Range: (1 – 3000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12","search_zh":"水 废水 PN-EN ISO 5815-1:2019-12","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253f8d","lab_id":"69ad52a3de79e566650fb512","country":"PL","accr_number":"AB 1007","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu azotanowego Zakres: (0,05 – 22,0) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrate nitrogen concentration Range: (0,05 – 22,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego Zakres: (0,05 – 22,0) mg/l Metoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu azotanowego Zakres: (0,05 – 22,0) mg/l Metoda spektrofotometryczna PN-82/C-04576/08 Woda Scieki Stezenie azotu azotanowego Zakres: (0,05 – 22,0) mg/l Metoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Nitrate nitrogen concentration Range: (0,05 – 22,0) mg/l Spectrophotometric method PN-82/C-04576/08","search_zh":"水 废水 PN-82/C-04576/08","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253f8e","lab_id":"69ad52a3de79e566650fb512","country":"PL","accr_number":"AB 1007","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu azotynowego Zakres: (0,009 – 6,00) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrite nitrogen concentration Range: (0,009 – 6,00) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego Zakres: (0,009 – 6,00) mg/l Metoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu azotynowego Zakres: (0,009 – 6,00) mg/l Metoda spektrofotometryczna PN-EN 26777:1999 Woda Scieki Stezenie azotu azotynowego Zakres: (0,009 – 6,00) mg/l Metoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Nitrite nitrogen concentration Range: (0,009 – 6,00) mg/l Spectrophotometric method PN-EN 26777:1999","search_zh":"水 废水 PN-EN 26777:1999","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253f8f","lab_id":"69ad52a3de79e566650fb512","country":"PL","accr_number":"AB 1007","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie fosforu ogólnego Zakres: (0,10 – 50,0) mg/l Metoda spektrofotometryczna","methodology_en":"Total phosphorus concentration Range: (0,10 – 50,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego Zakres: (0,10 – 50,0) mg/l Metoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie fosforu ogólnego Zakres: (0,10 – 50,0) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010 Woda Scieki Stezenie fosforu ogolnego Zakres: (0,10 – 50,0) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Total phosphorus concentration Range: (0,10 – 50,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","search_zh":"水 废水 PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253f90","lab_id":"69ad52a3de79e566650fb512","country":"PL","accr_number":"AB 1007","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu amonowego Zakres: (0,050 – 300) mg/l Metoda spektrofotometryczna","methodology_en":"Ammonium nitrogen concentration Range: (0,050 – 300) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego Zakres: (0,050 – 300) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu amonowego Zakres: (0,050 – 300) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002 Woda Scieki Stezenie azotu amonowego Zakres: (0,050 – 300) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Ammonium nitrogen concentration Range: (0,050 – 300) mg/l Spectrophotometric method PN-ISO 7150-1:2002","search_zh":"水 废水 PN-ISO 7150-1:2002","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253f91","lab_id":"69ad52a3de79e566650fb512","country":"PL","accr_number":"AB 1007","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Przewodność elektryczna właściwa Zakres: (84 – 2500) μS/cm Metoda konduktometryczna","methodology_en":"Electrical conductivity Range: (84 – 2500) μS/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (84 – 2500) μS/cm Metoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Przewodność elektryczna właściwa Zakres: (84 – 2500) μS/cm Metoda konduktometryczna PN-EN 27888:1999 Woda Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa Zakres: (84 – 2500) μS/cm Metoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Electrical conductivity Range: (84 – 2500) μS/cm Conductometric method PN-EN 27888:1999","search_zh":"水 生活饮用水 PN-EN 27888:1999","test_object_zh":"水 生活饮用水"},{"_id":"6a5a56019af9f73f38253f92","lab_id":"69ad52a3de79e566650fb512","country":"PL","accr_number":"AB 1007","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi Ścieki","test_object_en":"Water Water intended for human consumption Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,5 – 6,0) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD 5 Range: (0,5 – 6,0) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,5 – 6,0) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Ścieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,5 – 6,0) mg/l O 2 Metoda elektrochemiczna PN-EN 1899-2:2002 Woda Woda do spozycia przez ludzi Scieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,5 – 6,0) mg/l O 2 Metoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Wastewater Biochemical oxygen demand - BOD 5 Range: (0,5 – 6,0) mg/l O 2 Electrochemical method PN-EN 1899-2:2002","search_zh":"水 生活饮用水 废水 五日生化需氧量 BZT 5 范围：(0,5 – 6,0) mg/l O 2 电化学法 PN-EN 1899-2:2002","test_object_zh":"水 生活饮用水 废水","methodology_zh":"五日生化需氧量 BZT 5 范围：(0,5 – 6,0) mg/l O 2 电化学法"},{"_id":"6a5a56019af9f73f38253f93","lab_id":"69ad52a3de79e566650fb512","country":"PL","accr_number":"AB 1007","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi Ścieki","test_object_en":"Water Water intended for human consumption Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (10 – 10000) mg/l O 2 Metoda spektrofotometryczna","methodology_en":"Chemical oxygen demand - COD-Cr Range: (10 – 10000) mg/l O 2 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (10 – 10000) mg/l O 2 Metoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (10 – 10000) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005 Woda Woda do spozycia przez ludzi Scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (10 – 10000) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Wastewater Chemical oxygen demand - COD-Cr Range: (10 – 10000) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005","search_zh":"水 生活饮用水 废水 PN-ISO 15705:2005","test_object_zh":"水 生活饮用水 废水"},{"_id":"6a5a56019af9f73f38253f94","lab_id":"69ad52a3de79e566650fb512","country":"PL","accr_number":"AB 1007","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi Ścieki","test_object_en":"Water Water intended for human consumption Wastewater","methodology":"Zawiesiny ogólne Zakres: (2,0 – 3000) mg/l Metoda wagowa","methodology_en":"Total suspended solids (TSS) Range: (2,0 – 3000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: (2,0 – 3000) mg/l Metoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Ścieki Zawiesiny ogólne Zakres: (2,0 – 3000) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007 Woda Woda do spozycia przez ludzi Scieki Zawiesiny ogolne Zakres: (2,0 – 3000) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Wastewater Total suspended solids (TSS) Range: (2,0 – 3000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007","search_zh":"水 生活饮用水 废水 总悬浮物 范围：(2,0 – 3000) mg/l 重量法 PN-EN 872:2007+Ap1:2007","test_object_zh":"水 生活饮用水 废水","methodology_zh":"总悬浮物 范围：(2,0 – 3000) mg/l 重量法"},{"_id":"6a5a56019af9f73f38253f95","lab_id":"69ad52a3de79e566650fb512","country":"PL","accr_number":"AB 1007","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi Ścieki","test_object_en":"Water Water intended for human consumption Wastewater","methodology":"Stężenie chlorków Zakres: (5,0 – 1000) mg/l Metoda miareczkowa","methodology_en":"Chloride concentration Range: (5,0 – 1000) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (5,0 – 1000) mg/l Metoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Ścieki Stężenie chlorków Zakres: (5,0 – 1000) mg/l Metoda miareczkowa PN-ISO 9297:1994 Woda Woda do spozycia przez ludzi Scieki Stezenie chlorkow Zakres: (5,0 – 1000) mg/l Metoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Wastewater Chloride concentration Range: (5,0 – 1000) mg/l Titrimetric method PN-ISO 9297:1994","search_zh":"水 生活饮用水 废水 氯化物浓度 范围：(5,0 – 1000) mg/l 滴定法 PN-ISO 9297:1994","test_object_zh":"水 生活饮用水 废水","methodology_zh":"氯化物浓度 范围：(5,0 – 1000) mg/l 滴定法"},{"_id":"6a5a56019af9f73f38253f96","lab_id":"69ad52a3de79e566650fb512","country":"PL","accr_number":"AB 1007","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi Ścieki","test_object_en":"Water Water intended for human consumption Wastewater","methodology":"Stężenie ortofosforanów Zakres: (0,050 – 150) mg/l Metoda spektrofotometryczna","methodology_en":"Orthophosphate concentration Range: (0,050 – 150) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie ortofosforanów Zakres: (0,050 – 150) mg/l Metoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Ścieki Stężenie ortofosforanów Zakres: (0,050 – 150) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+Ap2:2010 Woda Woda do spozycia przez ludzi Scieki Stezenie ortofosforanow Zakres: (0,050 – 150) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Wastewater Orthophosphate concentration Range: (0,050 – 150) mg/l Spectrophotometric method PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+Ap2:2010","search_zh":"水 生活饮用水 废水 PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+Ap2:2010","test_object_zh":"水 生活饮用水 废水"},{"_id":"6a5a56019af9f73f38253f97","lab_id":"69ad52a3de79e566650fb512","country":"PL","accr_number":"AB 1007","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi Ścieki","test_object_en":"Water Water intended for human consumption Wastewater","methodology":"Stężenie żelaza Zakres: (0,050 – 15,0) mg/l Metoda spektrofotometryczna","methodology_en":"Iron concentration Range: (0,050 – 15,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie żelaza Zakres: (0,050 – 15,0) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016","norm_bases":["PN-ISO 6332:2001+Ap1:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Ścieki Stężenie żelaza Zakres: (0,050 – 15,0) mg/l Metoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016 Woda Woda do spozycia przez ludzi Scieki Stezenie zelaza Zakres: (0,050 – 15,0) mg/l Metoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Wastewater Iron concentration Range: (0,050 – 15,0) mg/l Spectrophotometric method PN-ISO 6332:2001+Ap1:2016","search_zh":"水 生活饮用水 废水 PN-ISO 6332:2001+Ap1:2016","test_object_zh":"水 生活饮用水 废水"},{"_id":"6a5a56019af9f73f38253f98","lab_id":"69ad52a3de79e566650fb512","country":"PL","accr_number":"AB 1007","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi Ścieki","test_object_en":"Water Water intended for human consumption Wastewater","methodology":"pH Zakres: 4,0 – 10,0 Metoda potencjometryczna","methodology_en":"pH Range: 4,0 – 10,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 4,0 – 10,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Ścieki pH Zakres: 4,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Woda Woda do spozycia przez ludzi Scieki pH Zakres: 4,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Wastewater pH Range: 4,0 – 10,0 Potentiometric method PN-EN ISO 10523:2012","search_zh":"水 生活饮用水 废水 pH 范围：4,0 – 10,0 电位法 PN-EN ISO 10523:2012","test_object_zh":"水 生活饮用水 废水","methodology_zh":"pH 范围：4,0 – 10,0 电位法"}],"has_pdf":true}