{"lab":{"_id":"69ad52a3de79e566650fb50c","accr_number":"AB 1004","country":"PL","accr_body":"PCA","address":"ARTUR KAŁA, TOMASZ POLAK, LESZEK SIEROCIŃSKI, ul. Rejtana 23, 42-200 Częstochowa","categories":["environment","materials"],"city":"Częstochowa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":105,"name":"”LAB-SERWIS” LABORATORIUM BADAŃ ŚRODOWISKA S.C.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1004.pdf"],"scope_summary":"","search_text":"”lab-serwis” laboratorium badań środowiska s.c. artur kała, tomasz polak, leszek sierociński, ul. rejtana 23, 42-200 częstochowa environment materials other construction electronics automotive metrology","status":"active","updated_at":"2026-03-08T14:50:11.002Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T07:42:40.016Z","parse_date":"2026-08-13T07:42:40.016Z","parse_source":"agent-claude-code","email_confidence":"low","email_mx":true,"email_source":"https://www.lab-serwis.com.pl/kontakt.html","needs_review":true,"review_reason":"e-mail niepewny (low) — zweryfikuj","fields_of_testing":[{"codes":"C/33/P","pl":"Badania chemiczne i pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze, pyły)","en":"Chemical tests and sampling - working environment (harmful factors – air, dust)"},{"codes":"C/36/P","pl":"Badania chemiczne i pobieranie próbek gazów odlotowych","en":"Chemical tests and sampling of waste gases"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, oświetlenie, drgania, mikroklimat, wydatek energetyczny)","en":"Tests concerning environmental engineering (environmental and climatic) - working environment (harmful and nuisance factors – noise, lighting, vibration, microclimate, energy expenditure)"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne - hałas)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors - noise)"},{"codes":"G/36","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – gazy (gazy odlotowe)","en":"Tests concerning environmental engineering (environmental and climatic) – gases (waste gases)"},{"codes":"M/39","pl":"Badania inne urządzeń ochrony powietrza","en":"Other tests air protection equipment"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Tests of physical properties and sampling) – working environment (harmful factors - air)"},{"codes":"N/36/P","pl":"Badania właściwości fizycznych i pobieranie próbek gazów odlotowych","en":"Tests of physical properties and sampling of waste gases"},{"codes":"P/33","pl":"Pobieranie próbek powietrza","en":"Sampling of air"},{"codes":"P/36","pl":"Pobieranie próbek gazów odlotowych","en":"Sampling of waste gases"}],"issue":{"no":"30","date":"16.04.2026"},"map_coord":[50.795335,19.136047],"map_geo":"nominatim-street","lab_locations":[{"name":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/5655048c13636981daf79e5e18c8331b/AB%201004.pdf","has_en":true,"category_counts":{"environment":77,"other":26,"materials":5,"construction":2},"category_scores":{"environment":53.9,"other":6.15,"materials":0.23,"construction":0.04},"has_zh":true,"lab_locations_zh":[{"name":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7d7570441eff5f15648711","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Pobieranie próbek w celu oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"metale i ich związki, w tym"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"substancje organiczne, w tym"},{"name":"frakcja wdychalna"},{"name":"substancje nieorganiczne, w tym"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"frakcja torakalna"},{"name":"azbest – włókna respirabilne"},{"name":"sztuczne włókna mineralne z wyjątkiem ogniotrwałych włókien ceramicznych – włókna respirabilne"},{"name":"węglik krzemu włóknisty – włókna respirabilne"},{"name":"ogniotrwałe włókna ceramiczne"},{"name":"ogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek w celu oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje organiczne, w tym\nfrakcja wdychalna\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nfrakcja torakalna\nazbest – włókna respirabilne\nsztuczne włókna mineralne z wyjątkiem ogniotrwałych włókien ceramicznych – włókna respirabilne\nwęglik krzemu włóknisty – włókna respirabilne\nogniotrwałe włókna ceramiczne\nogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002/Az1:2004"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Pobieranie próbek w celu oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje organiczne, w tym\nfrakcja wdychalna\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nfrakcja torakalna\nazbest – włókna respirabilne\nsztuczne włókna mineralne z wyjątkiem ogniotrwałych włókien ceramicznych – włókna respirabilne\nwęglik krzemu włóknisty – włókna respirabilne\nogniotrwałe włókna ceramiczne\nogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004 Srodowisko pracy – powietrze Pobieranie probek w celu oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe\nfrakcja wdychalna\nfrakcja respirabilna\nmetale i ich zwiazki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje organiczne, w tym\nfrakcja wdychalna\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nfrakcja torakalna\nazbest – wlokna respirabilne\nsztuczne wlokna mineralne z wyjatkiem ogniotrwalych wlokien ceramicznych – wlokna respirabilne\nweglik krzemu wloknisty – wlokna respirabilne\nogniotrwale wlokna ceramiczne\nogniotrwale wlokna ceramiczne w mieszaninie z innymi sztucznymi wloknami mineralnymi\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","categories":["materials","environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"metals and their compounds, including"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"organic substances, including"},{"name":"inhalable fraction"},{"name":"inorganic substances, including"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"thoracic fraction"},{"name":"asbestos – respirable fibres"},{"name":"man-made mineral fibres excluding refractory ceramic fibres – respirable fibres"},{"name":"silicon carbide fibrous – respirable fibres"},{"name":"refractory ceramic fibres"},{"name":"refractory ceramic fibres mixed with other man-made mineral fibres"}],"search_en":"Workplace environment – air Sampling for the assessment of occupational exposure to: Personal dosimetry method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński dust agents inhalable fraction respirable fraction metals and their compounds, including inhalable fraction respirable fraction organic substances, including inhalable fraction inorganic substances, including inhalable fraction respirable fraction thoracic fraction asbestos – respirable fibres man-made mineral fibres excluding refractory ceramic fibres – respirable fibres silicon carbide fibrous – respirable fibres refractory ceramic fibres refractory ceramic fibres mixed with other man-made mineral fibres PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"粉尘因素"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"金属及其化合物，包括"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"有机物质，包括"},{"name":"可吸入组分"},{"name":"无机物质，包括"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"胸腔组分"},{"name":"石棉 — 呼吸性纤维"},{"name":"人造矿物纤维，耐火陶瓷纤维除外 － 呼吸性纤维"},{"name":"纤维状碳化硅 － 呼吸性纤维"},{"name":"耐火陶瓷纤维"},{"name":"与其他人造矿物纤维混合的耐火陶瓷纤维"}],"search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 粉尘因素 可吸入组分 呼吸性组分 金属及其化合物，包括 可吸入组分 呼吸性组分 有机物质，包括 可吸入组分 无机物质，包括 可吸入组分 呼吸性组分 胸腔组分 石棉 — 呼吸性纤维 人造矿物纤维，耐火陶瓷纤维除外 － 呼吸性纤维 纤维状碳化硅 － 呼吸性纤维 耐火陶瓷纤维 与其他人造矿物纤维混合的耐火陶瓷纤维 PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_zh":"职业接触评估采样，针对："},{"_id":"6a7d7570441eff5f15648712","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002/Az1:2004"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004 Srodowisko pracy – powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment – air Exposure index (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","test_object_en":"Workplace environment – air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński"},{"_id":"6a7d7570441eff5f15648713","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna","parameters":[{"name":"apatyty i fosforyty"},{"name":"cement portlandzki"},{"name":"ditlenek tytanu"},{"name":"grafit naturalny"},{"name":"grafit syntetyczny"},{"name":"kaolin"},{"name":"krzemionka bezpostaciowa i syntetyczna"},{"name":"pyły drewna"},{"name":"pyły mąki"},{"name":"pyły niesklasyfikowane ze względu na toksyczność"},{"name":"pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"sadza techniczna"},{"name":"siarczan (VI) wapnia (gips)"},{"name":"talk"},{"name":"węgiel (kamienny, brunatny)"},{"name":"węglan magnezu wapnia (dolomit)"},{"name":"węglik krzemu, niewłóknisty"},{"name":"węglik krzemu, włóknisty"},{"name":"sztuczne włókna mineralne z wyjątkiem ogniotrwałych włókien ceramicznych"},{"name":"Zakres","range":"(0,1–20,5) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\napatyty i fosforyty\ncement portlandzki\nditlenek tytanu\ngrafit naturalny\ngrafit syntetyczny\nkaolin\nkrzemionka bezpostaciowa i syntetyczna\npyły drewna\npyły mąki\npyły niesklasyfikowane ze względu na toksyczność\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nsadza techniczna\nsiarczan (VI) wapnia (gips)\ntalk\nwęgiel (kamienny, brunatny)\nwęglan magnezu wapnia (dolomit)\nwęglik krzemu, niewłóknisty\nwęglik krzemu, włóknisty\nsztuczne włókna mineralne z wyjątkiem ogniotrwałych włókien ceramicznych\nZakres (0,1–20,5) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\napatyty i fosforyty\ncement portlandzki\nditlenek tytanu\ngrafit naturalny\ngrafit syntetyczny\nkaolin\nkrzemionka bezpostaciowa i syntetyczna\npyły drewna\npyły mąki\npyły niesklasyfikowane ze względu na toksyczność\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nsadza techniczna\nsiarczan (VI) wapnia (gips)\ntalk\nwęgiel (kamienny, brunatny)\nwęglan magnezu wapnia (dolomit)\nwęglik krzemu, niewłóknisty\nwęglik krzemu, włóknisty\nsztuczne włókna mineralne z wyjątkiem ogniotrwałych włókien ceramicznych\nZakres (0,1–20,5) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\napatyty i fosforyty\ncement portlandzki\nditlenek tytanu\ngrafit naturalny\ngrafit syntetyczny\nkaolin\nkrzemionka bezpostaciowa i syntetyczna\npyly drewna\npyly maki\npyly niesklasyfikowane ze wzgledu na toksycznosc\npyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nsadza techniczna\nsiarczan (VI) wapnia (gips)\ntalk\nwegiel (kamienny, brunatny)\nweglan magnezu wapnia (dolomit)\nweglik krzemu, niewloknisty\nweglik krzemu, wloknisty\nsztuczne wlokna mineralne z wyjatkiem ogniotrwalych wlokien ceramicznych\nZakres (0,1–20,5) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Concentration of harmful dust agents – inhalable fraction","parameters_en":[{"name":"apatites and phosphorites"},{"name":"portland cement"},{"name":"titanium dioxide"},{"name":"natural graphite"},{"name":"synthetic graphite"},{"name":"kaolin"},{"name":"amorphous and synthetic silica"},{"name":"wood dusts"},{"name":"flour dusts"},{"name":"dusts not classified according to toxicity"},{"name":"organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"carbon black"},{"name":"calcium sulfate (VI) (gypsum)"},{"name":"talc"},{"name":"coal (hard, brown)"},{"name":"calcium magnesium carbonate (dolomite)"},{"name":"silicon carbide, non-fibrous"},{"name":"silicon carbide, fibrous"},{"name":"man-made mineral fibres excluding refractory ceramic fibres"},{"name":"Range","range":"(0,1–20,5) mg/m3"}],"search_en":"Workplace environment – air Concentration of harmful dust agents – inhalable fraction Gravimetric method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński apatites and phosphorites portland cement titanium dioxide natural graphite synthetic graphite kaolin amorphous and synthetic silica wood dusts flour dusts dusts not classified according to toxicity organic dusts of animal and plant origin, excluding wood and flour dusts carbon black calcium sulfate (VI) (gypsum) talc coal (hard, brown) calcium magnesium carbonate (dolomite) silicon carbide, non-fibrous silicon carbide, fibrous man-made mineral fibres excluding refractory ceramic fibres Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"天然石墨"},{"name":"合成石墨"},{"name":"高岭土"},{"name":"无定形与合成二氧化硅"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"炭黑"},{"name":"硫酸钙（VI）（石膏）"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"碳酸钙镁（白云石）"},{"name":"碳化硅，非纤维状"},{"name":"碳化硅，纤维状"},{"name":"人造矿物纤维，耐火陶瓷纤维除外"},{"name":"范围","range":"(0,1–20,5) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分 重量法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 磷灰石与磷块岩 硅酸盐水泥 二氧化钛 天然石墨 合成石墨 高岭土 无定形与合成二氧化硅 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 炭黑 硫酸钙（VI）（石膏） 滑石 煤（烟煤、褐煤） 碳酸钙镁（白云石） 碳化硅，非纤维状 碳化硅，纤维状 人造矿物纤维，耐火陶瓷纤维除外 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_zh":"有害粉尘因素浓度 — 可吸入组分"},{"_id":"6a7d7570441eff5f15648714","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna","parameters":[{"name":"apatyty i fosforyty"},{"name":"cement portlandzki"},{"name":"grafit naturalny"},{"name":"krzemionka bezpostaciowa i syntetyczna"},{"name":"pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"spaliny silnika Diesla"},{"name":"talk"},{"name":"węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,05 – 40,7) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\napatyty i fosforyty\ncement portlandzki\ngrafit naturalny\nkrzemionka bezpostaciowa i syntetyczna\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nspaliny silnika Diesla\ntalk\nwęgiel (kamienny, brunatny)\nZakres (0,05 – 40,7) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\napatyty i fosforyty\ncement portlandzki\ngrafit naturalny\nkrzemionka bezpostaciowa i syntetyczna\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nspaliny silnika Diesla\ntalk\nwęgiel (kamienny, brunatny)\nZakres (0,05 – 40,7) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\napatyty i fosforyty\ncement portlandzki\ngrafit naturalny\nkrzemionka bezpostaciowa i syntetyczna\npyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nspaliny silnika Diesla\ntalk\nwegiel (kamienny, brunatny)\nZakres (0,05 – 40,7) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Concentration of harmful dust agents – respirable fraction","parameters_en":[{"name":"apatites and phosphorites"},{"name":"portland cement"},{"name":"natural graphite"},{"name":"amorphous and synthetic silica"},{"name":"organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"diesel engine exhaust"},{"name":"talc"},{"name":"coal (hard, brown)"},{"name":"Range","range":"(0,05 – 40,7) mg/m3"}],"search_en":"Workplace environment – air Concentration of harmful dust agents – respirable fraction Gravimetric method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński apatites and phosphorites portland cement natural graphite amorphous and synthetic silica organic dusts of animal and plant origin, excluding wood and flour dusts diesel engine exhaust talc coal (hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"天然石墨"},{"name":"无定形与合成二氧化硅"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"柴油机排气"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,05 – 40,7) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 呼吸性组分 重量法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 磷灰石与磷块岩 硅酸盐水泥 天然石墨 无定形与合成二氧化硅 动植物来源有机粉尘，木粉和面粉除外 柴油机排气 滑石 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分"},{"_id":"6a7d7570441eff5f15648715","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie/zawartość tlenku azotu","parameters":[{"name":"Zakres","range":"(0,23 – 9,12) mg/m3"},{"name":"Zakres","range":"(0,18 – 7,31) ppm"},{"name":"Zakres","range":"(0,0013 – 0,052) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość tlenku azotu\nZakres:\nZakres (0,23 – 9,12) mg/m3\nZakres (0,18 – 7,31) ppm\nZakres (0,0013 – 0,052) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04009-11:2008","norm_bases":["PN-Z-04009-11:2008"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie/zawartość tlenku azotu\nZakres:\nZakres (0,23 – 9,12) mg/m3\nZakres (0,18 – 7,31) ppm\nZakres (0,0013 – 0,052) mg w próbce\nMetoda spektrofotometryczna PN-Z-04009-11:2008 Srodowisko pracy – powietrze Stezenie/zawartosc tlenku azotu\nZakres:\nZakres (0,23 – 9,12) mg/m3\nZakres (0,18 – 7,31) ppm\nZakres (0,0013 – 0,052) mg w probce\nMetoda spektrofotometryczna PN-Z-04009-11:2008","categories":["environment"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Nitrogen monoxide concentration/content","parameters_en":[{"name":"Range","range":"(0,23 – 9,12) mg/m3"},{"name":"Range","range":"(0,18 – 7,31) ppm"},{"name":"Range","range":"(0,0013 – 0,052) mg w próbce"}],"search_en":"Workplace environment – air Nitrogen monoxide concentration/content Spectrophotometric method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range Range Range PN-Z-04009-11:2008","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"范围","range":"(0,23 – 9,12) mg/m3"},{"name":"范围","range":"(0,18 – 7,31) ppm"},{"name":"范围","range":"(0,0013 – 0,052) mg w próbce"}],"search_zh":"工作场所环境 — 空气 一氧化氮的浓度/含量 分光光度法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 范围 范围 PN-Z-04009-11:2008","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_zh":"一氧化氮的浓度/含量"},{"_id":"6a7d7570441eff5f15648716","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie/zawartość ditlenku azotu","parameters":[{"name":"Zakres","range":"(0,07 – 7,11) mg/m3"},{"name":"Zakres","range":"(0,037 – 3,715) ppm"},{"name":"Zakres","range":"(0,0004 – 0,016) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość ditlenku azotu\nZakres:\nZakres (0,07 – 7,11) mg/m3\nZakres (0,037 – 3,715) ppm\nZakres (0,0004 – 0,016) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04009-11:2008","norm_bases":["PN-Z-04009-11:2008"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie/zawartość ditlenku azotu\nZakres:\nZakres (0,07 – 7,11) mg/m3\nZakres (0,037 – 3,715) ppm\nZakres (0,0004 – 0,016) mg w próbce\nMetoda spektrofotometryczna PN-Z-04009-11:2008 Srodowisko pracy – powietrze Stezenie/zawartosc ditlenku azotu\nZakres:\nZakres (0,07 – 7,11) mg/m3\nZakres (0,037 – 3,715) ppm\nZakres (0,0004 – 0,016) mg w probce\nMetoda spektrofotometryczna PN-Z-04009-11:2008","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Nitrogen dioxide concentration/content","parameters_en":[{"name":"Range","range":"(0,07 – 7,11) mg/m3"},{"name":"Range","range":"(0,037 – 3,715) ppm"},{"name":"Range","range":"(0,0004 – 0,016) mg w próbce"}],"search_en":"Workplace environment – air Nitrogen dioxide concentration/content Spectrophotometric method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range Range Range PN-Z-04009-11:2008","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"范围","range":"(0,07 – 7,11) mg/m3"},{"name":"范围","range":"(0,037 – 3,715) ppm"},{"name":"范围","range":"(0,0004 – 0,016) mg w próbce"}],"search_zh":"工作场所环境 — 空气 二氧化氮的浓度/含量 分光光度法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 范围 范围 PN-Z-04009-11:2008","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_zh":"二氧化氮的浓度/含量"},{"_id":"6a7d7570441eff5f15648717","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie/zawartość kwasu azotowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie/zawartość kwasu azotowego (z obliczeń)","reference":"PN-Z-04009-11:2008","norm_bases":["PN-Z-04009-11:2008"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie/zawartość kwasu azotowego (z obliczeń) PN-Z-04009-11:2008 Srodowisko pracy – powietrze Stezenie/zawartosc kwasu azotowego (z obliczen) PN-Z-04009-11:2008","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Nitric acid concentration/content (calculated)","search_en":"Workplace environment – air Nitric acid concentration/content (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-Z-04009-11:2008","test_object_en":"Workplace environment – air","search_zh":"工作场所环境 — 空气 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-Z-04009-11:2008","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński"},{"_id":"6a7d7570441eff5f15648718","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie manganu i jego związków nieorganicznych w przeliczeniu na Mn","parameters":[{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,006 – 1,5) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu i jego związków nieorganicznych w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (0,006 – 1,5) mg/m3\nMetoda spektrofotometryczna","reference":"ILR 10 wydanie 4 z dnia 01.08.2018 r.","norm_bases":["ILR 10 wydanie 4 z dnia 01.08.2018 r."],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie manganu i jego związków nieorganicznych w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (0,006 – 1,5) mg/m3\nMetoda spektrofotometryczna ILR 10 wydanie 4 z dnia 01.08.2018 r. Srodowisko pracy – powietrze Stezenie manganu i jego zwiazkow nieorganicznych w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (0,006 – 1,5) mg/m3\nMetoda spektrofotometryczna ILR 10 wydanie 4 z dnia 01.08.2018 r.","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Concentration of manganese and its inorganic compounds calculated as Mn","parameters_en":[{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"Range","range":"(0,006 – 1,5) mg/m3"}],"search_en":"Workplace environment – air Concentration of manganese and its inorganic compounds calculated as Mn Spectrophotometric method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński inhalable fraction respirable fraction Range ILR 10 wydanie 4 z dnia 01.08.2018 r.","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"范围","range":"(0,006 – 1,5) mg/m3"}],"search_zh":"工作场所环境 — 空气 锰及其无机化合物浓度（以 Mn 计） 分光光度法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 可吸入组分 呼吸性组分 范围 ILR 10 wydanie 4 z dnia 01.08.2018 r.","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_zh":"锰及其无机化合物浓度（以 Mn 计）"},{"_id":"6a7d7570441eff5f15648719","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie tlenków żelaza w przeliczeniu na Fe – frakcja wdychalna – frakcja respirabilna","parameters":[{"name":"Zakres","range":"(0,07 – 166,6) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie tlenków żelaza w przeliczeniu na Fe – frakcja wdychalna – frakcja respirabilna\nZakres (0,07 – 166,6) mg/m3\nMetoda spektrofotometryczna","reference":"ILR 10 wydanie 4 z dnia 01.08.2018 r.","norm_bases":["ILR 10 wydanie 4 z dnia 01.08.2018 r."],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie tlenków żelaza w przeliczeniu na Fe – frakcja wdychalna – frakcja respirabilna\nZakres (0,07 – 166,6) mg/m3\nMetoda spektrofotometryczna ILR 10 wydanie 4 z dnia 01.08.2018 r. Srodowisko pracy – powietrze Stezenie tlenkow zelaza w przeliczeniu na Fe – frakcja wdychalna – frakcja respirabilna\nZakres (0,07 – 166,6) mg/m3\nMetoda spektrofotometryczna ILR 10 wydanie 4 z dnia 01.08.2018 r.","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Concentration of iron oxides calculated as Fe – inhalable fraction – respirable fraction","parameters_en":[{"name":"Range","range":"(0,07 – 166,6) mg/m3"}],"search_en":"Workplace environment – air Concentration of iron oxides calculated as Fe – inhalable fraction – respirable fraction Spectrophotometric method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range ILR 10 wydanie 4 z dnia 01.08.2018 r.","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"范围","range":"(0,07 – 166,6) mg/m3"}],"search_zh":"工作场所环境 — 空气 分光光度法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 ILR 10 wydanie 4 z dnia 01.08.2018 r.","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński"},{"_id":"6a7d7570441eff5f1564871a","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie tlenku węgla","parameters":[{"name":"Zakres","range":"(2,3 – 243,6) mg/m3"},{"name":"Zakres","range":"(2,0 – 210) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenku węgla\nZakres:\nZakres (2,3 – 243,6) mg/m3\nZakres (2,0 – 210) ppm\nMetoda elektrochemiczna","reference":"ILR 11 wydanie 2 z dnia 16.11.2021 r.","norm_bases":["ILR 11 wydanie 2 z dnia 16.11.2021 r."],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie tlenku węgla\nZakres:\nZakres (2,3 – 243,6) mg/m3\nZakres (2,0 – 210) ppm\nMetoda elektrochemiczna ILR 11 wydanie 2 z dnia 16.11.2021 r. Srodowisko pracy – powietrze Stezenie tlenku wegla\nZakres:\nZakres (2,3 – 243,6) mg/m3\nZakres (2,0 – 210) ppm\nMetoda elektrochemiczna ILR 11 wydanie 2 z dnia 16.11.2021 r.","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Carbon monoxide concentration","parameters_en":[{"name":"Range","range":"(2,3 – 243,6) mg/m3"},{"name":"Range","range":"(2,0 – 210) ppm"}],"search_en":"Workplace environment – air Carbon monoxide concentration Electrochemical method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range Range ILR 11 wydanie 2 z dnia 16.11.2021 r.","technique_en":"Electrochemical method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"范围","range":"(2,3 – 243,6) mg/m3"},{"name":"范围","range":"(2,0 – 210) ppm"}],"search_zh":"工作场所环境 — 空气 一氧化碳浓度 电化学法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 范围 ILR 11 wydanie 2 z dnia 16.11.2021 r.","technique_zh":"电化学法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_zh":"一氧化碳浓度"},{"_id":"6a7d7570441eff5f1564871b","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Wskaźniki narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźniki narażenia (z obliczeń)","reference":"ILR 11 wydanie 2 z dnia 16.11.2021 r.","norm_bases":["ILR 11 wydanie 2 z dnia 16.11.2021 r."],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Wskaźniki narażenia (z obliczeń) ILR 11 wydanie 2 z dnia 16.11.2021 r. Srodowisko pracy – powietrze Wskazniki narazenia (z obliczen) ILR 11 wydanie 2 z dnia 16.11.2021 r.","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Exposure indices (calculated)","search_en":"Workplace environment – air Exposure indices (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński ILR 11 wydanie 2 z dnia 16.11.2021 r.","test_object_en":"Workplace environment – air","search_zh":"工作场所环境 — 空气 暴露指数（计算值） ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński ILR 11 wydanie 2 z dnia 16.11.2021 r.","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_zh":"暴露指数（计算值）"},{"_id":"6a7d7570441eff5f1564871c","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie/zawartość amoniaku","parameters":[{"name":"Zakres","range":"(1,3 – 450) mg/m3"},{"name":"Zakres","range":"(0,02 – 2,25) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość amoniaku\nZakres:\nZakres (1,3 – 450) mg/m3\nZakres (0,02 – 2,25) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-71/Z-04041","norm_bases":["PN-71/Z-04041"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie/zawartość amoniaku\nZakres:\nZakres (1,3 – 450) mg/m3\nZakres (0,02 – 2,25) mg w próbce\nMetoda spektrofotometryczna PN-71/Z-04041 Srodowisko pracy – powietrze Stezenie/zawartosc amoniaku\nZakres:\nZakres (1,3 – 450) mg/m3\nZakres (0,02 – 2,25) mg w probce\nMetoda spektrofotometryczna PN-71/Z-04041","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Ammonia concentration/content","parameters_en":[{"name":"Range","range":"(1,3 – 450) mg/m3"},{"name":"Range","range":"(0,02 – 2,25) mg w próbce"}],"search_en":"Workplace environment – air Ammonia concentration/content Spectrophotometric method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range Range PN-71/Z-04041","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"范围","range":"(1,3 – 450) mg/m3"},{"name":"范围","range":"(0,02 – 2,25) mg w próbce"}],"search_zh":"工作场所环境 — 空气 氨浓度/含量 分光光度法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 范围 PN-71/Z-04041","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_zh":"氨浓度/含量"},{"_id":"6a7d7570441eff5f1564871d","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie/zawartość chlorowodoru","parameters":[{"name":"Zakres","range":"(0,5 – 125,0) mg/m3"},{"name":"Zakres","range":"(0,01 – 2,50) mg w próbce"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"computed":[],"activity":"Stężenie/zawartość chlorowodoru\nZakres:\nZakres (0,5 – 125,0) mg/m3\nZakres (0,01 – 2,50) mg w próbce\nMetoda turbidymetryczna","reference":"PN-93/Z-04225/03","norm_bases":["PN-93/Z-04225/03"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie/zawartość chlorowodoru\nZakres:\nZakres (0,5 – 125,0) mg/m3\nZakres (0,01 – 2,50) mg w próbce\nMetoda turbidymetryczna PN-93/Z-04225/03 Srodowisko pracy – powietrze Stezenie/zawartosc chlorowodoru\nZakres:\nZakres (0,5 – 125,0) mg/m3\nZakres (0,01 – 2,50) mg w probce\nMetoda turbidymetryczna PN-93/Z-04225/03","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Hydrogen chloride concentration/content","parameters_en":[{"name":"Range","range":"(0,5 – 125,0) mg/m3"},{"name":"Range","range":"(0,01 – 2,50) mg w próbce"}],"search_en":"Workplace environment – air Hydrogen chloride concentration/content Turbidimetric method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range Range PN-93/Z-04225/03","technique_en":"Turbidimetric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"范围","range":"(0,5 – 125,0) mg/m3"},{"name":"范围","range":"(0,01 – 2,50) mg w próbce"}],"search_zh":"工作场所环境 — 空气 氯化氢的浓度/含量 浊度法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 范围 PN-93/Z-04225/03","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","technique_zh":"浊度法","methodology_zh":"氯化氢的浓度/含量"},{"_id":"6a7d7570441eff5f1564871e","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie/zawartość fluorków","parameters":[{"name":"Zakres","range":"(0,1 – 500) mg/m3"},{"name":"Zakres","range":"(0,002 – 10) mg w próbce"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Stężenie/zawartość fluorków\nZakres:\nZakres (0,1 – 500) mg/m3\nZakres (0,002 – 10) mg w próbce\nMetoda potencjometryczna","reference":"ISO 15713-2006","norm_bases":["ISO 15713-2006"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie/zawartość fluorków\nZakres:\nZakres (0,1 – 500) mg/m3\nZakres (0,002 – 10) mg w próbce\nMetoda potencjometryczna ISO 15713-2006 Srodowisko pracy – powietrze Stezenie/zawartosc fluorkow\nZakres:\nZakres (0,1 – 500) mg/m3\nZakres (0,002 – 10) mg w probce\nMetoda potencjometryczna ISO 15713-2006","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Concentration/content of fluorides","parameters_en":[{"name":"Range","range":"(0,1 – 500) mg/m3"},{"name":"Range","range":"(0,002 – 10) mg w próbce"}],"search_en":"Workplace environment – air Concentration/content of fluorides Potentiometric method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range Range ISO 15713-2006","technique_en":"Potentiometric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"范围","range":"(0,1 – 500) mg/m3"},{"name":"范围","range":"(0,002 – 10) mg w próbce"}],"search_zh":"工作场所环境 — 空气 电位法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 范围 ISO 15713-2006","technique_zh":"电位法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński"},{"_id":"6a7d7570441eff5f1564871f","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie fluorków wyrażone jako fluorowodór (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie fluorków wyrażone jako fluorowodór (z obliczeń)","reference":"ISO 15713-2006","norm_bases":["ISO 15713-2006"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie fluorków wyrażone jako fluorowodór (z obliczeń) ISO 15713-2006 Srodowisko pracy – powietrze Stezenie fluorkow wyrazone jako fluorowodor (z obliczen) ISO 15713-2006","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Fluoride concentration expressed as hydrogen fluoride (calculated)","search_en":"Workplace environment – air Fluoride concentration expressed as hydrogen fluoride (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński ISO 15713-2006","test_object_en":"Workplace environment – air","search_zh":"工作场所环境 — 空气 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński ISO 15713-2006","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński"},{"_id":"6a7d7570441eff5f15648720","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie/zawartość ozonu","parameters":[{"name":"Zakres","range":"(0,01 – 0,25) mg/m3"},{"name":"Zakres","range":"(0,001 – 0,01) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość ozonu\nZakres:\nZakres (0,01 – 0,25) mg/m3\nZakres (0,001 – 0,01) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04007-2:1994","norm_bases":["PN-Z-04007-2:1994"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie/zawartość ozonu\nZakres:\nZakres (0,01 – 0,25) mg/m3\nZakres (0,001 – 0,01) mg w próbce\nMetoda spektrofotometryczna PN-Z-04007-2:1994 Srodowisko pracy – powietrze Stezenie/zawartosc ozonu\nZakres:\nZakres (0,01 – 0,25) mg/m3\nZakres (0,001 – 0,01) mg w probce\nMetoda spektrofotometryczna PN-Z-04007-2:1994","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Ozone concentration/content","parameters_en":[{"name":"Range","range":"(0,01 – 0,25) mg/m3"},{"name":"Range","range":"(0,001 – 0,01) mg w próbce"}],"search_en":"Workplace environment – air Ozone concentration/content Spectrophotometric method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range Range PN-Z-04007-2:1994","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"范围","range":"(0,01 – 0,25) mg/m3"},{"name":"范围","range":"(0,001 – 0,01) mg w próbce"}],"search_zh":"工作场所环境 — 空气 臭氧的浓度/含量 分光光度法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 范围 PN-Z-04007-2:1994","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_zh":"臭氧的浓度/含量"},{"_id":"6a7d7570441eff5f15648721","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie/zawartość chromu VI","parameters":[{"name":"Zakres","range":"(0,002 – 1,6) mg/m3"},{"name":"Zakres","range":"(0,002 – 0,08) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość chromu VI\nZakres:\nZakres (0,002 – 1,6) mg/m3\nZakres (0,002 – 0,08) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-87/Z-04126.03","norm_bases":["PN-87/Z-04126.03"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie/zawartość chromu VI\nZakres:\nZakres (0,002 – 1,6) mg/m3\nZakres (0,002 – 0,08) mg w próbce\nMetoda spektrofotometryczna PN-87/Z-04126.03 Srodowisko pracy – powietrze Stezenie/zawartosc chromu VI\nZakres:\nZakres (0,002 – 1,6) mg/m3\nZakres (0,002 – 0,08) mg w probce\nMetoda spektrofotometryczna PN-87/Z-04126.03","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Concentration/content of chromium VI","parameters_en":[{"name":"Range","range":"(0,002 – 1,6) mg/m3"},{"name":"Range","range":"(0,002 – 0,08) mg w próbce"}],"search_en":"Workplace environment – air Concentration/content of chromium VI Spectrophotometric method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range Range PN-87/Z-04126.03","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"范围","range":"(0,002 – 1,6) mg/m3"},{"name":"范围","range":"(0,002 – 0,08) mg w próbce"}],"search_zh":"工作场所环境 — 空气 分光光度法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 范围 PN-87/Z-04126.03","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński"},{"_id":"6a7d7570441eff5f15648722","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie/zawartość formaldehydu","parameters":[{"name":"Zakres","range":"(0,05 – 10,0) mg/m3"},{"name":"Zakres","range":"(0,001 – 0,02) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość formaldehydu\nZakres:\nZakres (0,05 – 10,0) mg/m3\nZakres (0,001 – 0,02) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04045-04:1976","norm_bases":["PN-Z-04045-04:1976"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie/zawartość formaldehydu\nZakres:\nZakres (0,05 – 10,0) mg/m3\nZakres (0,001 – 0,02) mg w próbce\nMetoda spektrofotometryczna PN-Z-04045-04:1976 Srodowisko pracy – powietrze Stezenie/zawartosc formaldehydu\nZakres:\nZakres (0,05 – 10,0) mg/m3\nZakres (0,001 – 0,02) mg w probce\nMetoda spektrofotometryczna PN-Z-04045-04:1976","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Formaldehyde concentration/content","parameters_en":[{"name":"Range","range":"(0,05 – 10,0) mg/m3"},{"name":"Range","range":"(0,001 – 0,02) mg w próbce"}],"search_en":"Workplace environment – air Formaldehyde concentration/content Spectrophotometric method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range Range PN-Z-04045-04:1976","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"范围","range":"(0,05 – 10,0) mg/m3"},{"name":"范围","range":"(0,001 – 0,02) mg w próbce"}],"search_zh":"工作场所环境 — 空气 甲醛浓度/含量 分光光度法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 范围 PN-Z-04045-04:1976","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_zh":"甲醛浓度/含量"},{"_id":"6a7d7570441eff5f15648723","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość krystalicznej krzemionki (kwarc, krystobalit)","parameters":[{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,0063 – 1,26) mg/m3"},{"name":"Zakres","range":"(0,005 – 1,0) mg w próbce"}],"technique":"Metoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)","techniques":["Metoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)"],"computed":[],"activity":"Stężenie/zawartość krystalicznej krzemionki (kwarc, krystobalit)\nZakres:\nfrakcja respirabilna\nZakres (0,0063 – 1,26) mg/m3\nZakres (0,005 – 1,0) mg w próbce\nMetoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2012, zeszyt 4 (74), str. 117-130","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2012, zeszyt 4 (74), str. 117-130"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry Stężenie/zawartość krystalicznej krzemionki (kwarc, krystobalit)\nZakres:\nfrakcja respirabilna\nZakres (0,0063 – 1,26) mg/m3\nZakres (0,005 – 1,0) mg w próbce\nMetoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR) Podstawy i Metody Oceny Środowiska Pracy 2012, zeszyt 4 (74), str. 117-130 Srodowisko pracy – powietrze – probki powietrza pobrane na filtry Stezenie/zawartosc krystalicznej krzemionki (kwarc, krystobalit)\nZakres:\nfrakcja respirabilna\nZakres (0,0063 – 1,26) mg/m3\nZakres (0,005 – 1,0) mg w probce\nMetoda spektrometrii w zakresie podczerwieni z transformacja Fouriera (FT-IR) Podstawy i Metody Oceny Srodowiska Pracy 2012, zeszyt 4 (74), str. 117-130","categories":["environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Crystalline silica (quartz, cristobalite) concentration/content","parameters_en":[{"name":"respirable fraction"},{"name":"Range","range":"(0,0063 – 1,26) mg/m3"},{"name":"Range","range":"(0,005 – 1,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected on filters Crystalline silica (quartz, cristobalite) concentration/content Fourier transform infrared spectrometry (FT-IR) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński respirable fraction Range Range Podstawy i Metody Oceny Środowiska Pracy 2012, zeszyt 4 (74), str. 117-130","technique_en":"Fourier transform infrared spectrometry (FT-IR)","test_object_en":"Workplace environment – air – air samples collected on filters","parameters_zh":[{"name":"呼吸性组分"},{"name":"范围","range":"(0,0063 – 1,26) mg/m3"},{"name":"范围","range":"(0,005 – 1,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 结晶二氧化硅（石英、方石英）的浓度/含量 傅里叶变换红外光谱法（FT-IR） ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 呼吸性组分 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2012, zeszyt 4 (74), str. 117-130","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","methodology_zh":"结晶二氧化硅（石英、方石英）的浓度/含量","technique_zh":"傅里叶变换红外光谱法（FT-IR）"},{"_id":"6a7d7570441eff5f15648724","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Stężenie/zawartość cyjanowodoru i cyjanków w przeliczeniu na CN-","parameters":[{"name":"Zakres","range":"(0,1 – 20) mg/m3"},{"name":"Zakres","range":"(0,09 – 17,8) ppm"},{"name":"Zakres","range":"(0,0005 – 0,1) mg w próbce"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Stężenie/zawartość cyjanowodoru i cyjanków w przeliczeniu na CN-\nZakres:\nZakres (0,1 – 20) mg/m3\nZakres (0,09 – 17,8) ppm\nZakres (0,0005 – 0,1) mg w próbce\nMetoda potencjometryczna","reference":"PN-70/Z-04053 | ILR 16 wydanie 1 z dn. 01.03.2021 r.","norm_bases":["PN-70/Z-04053","ILR 16 wydanie 1 z dn. 01.03.2021 r."],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego Stężenie/zawartość cyjanowodoru i cyjanków w przeliczeniu na CN-\nZakres:\nZakres (0,1 – 20) mg/m3\nZakres (0,09 – 17,8) ppm\nZakres (0,0005 – 0,1) mg w próbce\nMetoda potencjometryczna PN-70/Z-04053 | ILR 16 wydanie 1 z dn. 01.03.2021 r. Srodowisko pracy – powietrze – probki powietrza pobrane do roztworu pochlaniajacego Stezenie/zawartosc cyjanowodoru i cyjankow w przeliczeniu na CN-\nZakres:\nZakres (0,1 – 20) mg/m3\nZakres (0,09 – 17,8) ppm\nZakres (0,0005 – 0,1) mg w probce\nMetoda potencjometryczna PN-70/Z-04053 | ILR 16 wydanie 1 z dn. 01.03.2021 r.","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Concentration/content of hydrogen cyanide and cyanides calculated as CN-","parameters_en":[{"name":"Range","range":"(0,1 – 20) mg/m3"},{"name":"Range","range":"(0,09 – 17,8) ppm"},{"name":"Range","range":"(0,0005 – 0,1) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into absorbing solution Concentration/content of hydrogen cyanide and cyanides calculated as CN- Potentiometric method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range Range Range PN-70/Z-04053 | ILR 16 wydanie 1 z dn. 01.03.2021 r.","technique_en":"Potentiometric method","test_object_en":"Workplace environment – air – air samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,1 – 20) mg/m3"},{"name":"范围","range":"(0,09 – 17,8) ppm"},{"name":"范围","range":"(0,0005 – 0,1) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 电位法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 范围 范围 PN-70/Z-04053 | ILR 16 wydanie 1 z dn. 01.03.2021 r.","technique_zh":"电位法","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品"},{"_id":"6a7d7570441eff5f15648725","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Stężenie/zawartość dekatlenku fosforu (pięciotlenku fosforu)","parameters":[{"name":"Zakres","range":"(0,1 – 5) mg/m3"},{"name":"Zakres","range":"(0,001 – 0,02) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość dekatlenku fosforu (pięciotlenku fosforu)\nZakres:\nZakres (0,1 – 5) mg/m3\nZakres (0,001 – 0,02) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04073-1:2014-8","norm_bases":["PN-Z-04073-1:2014-8"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego Stężenie/zawartość dekatlenku fosforu (pięciotlenku fosforu)\nZakres:\nZakres (0,1 – 5) mg/m3\nZakres (0,001 – 0,02) mg w próbce\nMetoda spektrofotometryczna PN-Z-04073-1:2014-8 Srodowisko pracy – powietrze – probki powietrza pobrane do roztworu pochlaniajacego Stezenie/zawartosc dekatlenku fosforu (pieciotlenku fosforu)\nZakres:\nZakres (0,1 – 5) mg/m3\nZakres (0,001 – 0,02) mg w probce\nMetoda spektrofotometryczna PN-Z-04073-1:2014-8","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Concentration/content of phosphorus decaoxide (phosphorus pentoxide)","parameters_en":[{"name":"Range","range":"(0,1 – 5) mg/m3"},{"name":"Range","range":"(0,001 – 0,02) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into absorbing solution Concentration/content of phosphorus decaoxide (phosphorus pentoxide) Spectrophotometric method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range Range PN-Z-04073-1:2014-8","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment – air – air samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,1 – 5) mg/m3"},{"name":"范围","range":"(0,001 – 0,02) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 分光光度法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 范围 PN-Z-04073-1:2014-8","technique_zh":"分光光度法","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品"},{"_id":"6a7d7570441eff5f15648726","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Zawartość kwasu fosforowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość kwasu fosforowego (z obliczeń)","reference":"PN-Z-04073-1:2014-8","norm_bases":["PN-Z-04073-1:2014-8"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego Zawartość kwasu fosforowego (z obliczeń) PN-Z-04073-1:2014-8 Srodowisko pracy – powietrze – probki powietrza pobrane do roztworu pochlaniajacego Zawartosc kwasu fosforowego (z obliczen) PN-Z-04073-1:2014-8","categories":["environment"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Phosphoric acid content (calculated)","search_en":"Workplace environment – air – air samples collected into absorbing solution Phosphoric acid content (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-Z-04073-1:2014-8","test_object_en":"Workplace environment – air – air samples collected into absorbing solution","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-Z-04073-1:2014-8","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品"},{"_id":"6a7d7570441eff5f15648727","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne we wnętrzach","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(0,5 – 10000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (0,5 – 10000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03 | ILR 7 wydanie 2 z dnia 30.10.2023 r.","norm_bases":["PN-83/E-04040.03","ILR 7 wydanie 2 z dnia 30.10.2023 r."],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (0,5 – 10000) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 | ILR 7 wydanie 2 z dnia 30.10.2023 r. Srodowisko pracy – oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (0,5 – 10000) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03 | ILR 7 wydanie 2 z dnia 30.10.2023 r.","categories":["environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(0,5 – 10000) lx"}],"search_en":"Workplace environment – indoor electric lighting Illuminance Direct measurement method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range PN-83/E-04040.03 | ILR 7 wydanie 2 z dnia 30.10.2023 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment – indoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(0,5 – 10000) lx"}],"search_zh":"工作场所环境 — 室内电气照明 照度 直接测量法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 PN-83/E-04040.03 | ILR 7 wydanie 2 z dnia 30.10.2023 r.","technique_zh":"直接测量法","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a7d7570441eff5f15648728","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne we wnętrzach","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03 | ILR 7 wydanie 2 z dnia 30.10.2023 r.","norm_bases":["PN-83/E-04040.03","ILR 7 wydanie 2 z dnia 30.10.2023 r."],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 | ILR 7 wydanie 2 z dnia 30.10.2023 r. Srodowisko pracy – oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03 | ILR 7 wydanie 2 z dnia 30.10.2023 r.","categories":["environment"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment – indoor electric lighting Illuminance uniformity (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-83/E-04040.03 | ILR 7 wydanie 2 z dnia 30.10.2023 r.","test_object_en":"Workplace environment – indoor electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 — 室内电气照明 照度均匀度（计算值） ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-83/E-04040.03 | ILR 7 wydanie 2 z dnia 30.10.2023 r.","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a7d7570441eff5f15648729","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie awaryjne","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(0,5 – 500) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (0,5 – 500) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2013-11 z wyłączeniem p. 4.2.3; 4.2.4; 4.2.7; 4.3.3; 4.3.4; 4.3.9; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 4.4.7; 5","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem p. 4.2.3; 4.2.4; 4.2.7; 4.3.3; 4.3.4; 4.3.9; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 4.4.7; 5"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie awaryjne Natężenie oświetlenia\nZakres (0,5 – 500) lx\nMetoda pomiarowa bezpośrednia PN-EN 1838:2013-11 z wyłączeniem p. 4.2.3; 4.2.4; 4.2.7; 4.3.3; 4.3.4; 4.3.9; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 4.4.7; 5 Srodowisko pracy – oswietlenie awaryjne Natezenie oswietlenia\nZakres (0,5 – 500) lx\nMetoda pomiarowa bezposrednia PN-EN 1838:2013-11 z wylaczeniem p. 4.2.3; 4.2.4; 4.2.7; 4.3.3; 4.3.4; 4.3.9; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 4.4.7; 5","categories":["environment"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(0,5 – 500) lx"}],"search_en":"Workplace environment – emergency lighting Illuminance Direct measurement method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range PN-EN 1838:2013-11 z wyłączeniem p. 4.2.3; 4.2.4; 4.2.7; 4.3.3; 4.3.4; 4.3.9; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 4.4.7; 5","technique_en":"Direct measurement method","test_object_en":"Workplace environment – emergency lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(0,5 – 500) lx"}],"search_zh":"工作场所环境 — 应急照明 照度 直接测量法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 PN-EN 1838:2013-11 z wyłączeniem p. 4.2.3; 4.2.4; 4.2.7; 4.3.3; 4.3.4; 4.3.9; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 4.4.7; 5","technique_zh":"直接测量法","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","test_object_zh":"工作场所环境 — 应急照明"},{"_id":"6a7d7570441eff5f1564872a","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie awaryjne","methodology":"Czas załączania","parameters":[{"name":"Zakres","range":"(4 – 9000) s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Czas załączania\nZakres (4 – 9000) s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2013-11 z wyłączeniem p. 4.2.3; 4.2.4; 4.2.7; 4.3.3; 4.3.4; 4.3.9; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 4.4.7; 5","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem p. 4.2.3; 4.2.4; 4.2.7; 4.3.3; 4.3.4; 4.3.9; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 4.4.7; 5"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie awaryjne Czas załączania\nZakres (4 – 9000) s\nMetoda pomiarowa bezpośrednia PN-EN 1838:2013-11 z wyłączeniem p. 4.2.3; 4.2.4; 4.2.7; 4.3.3; 4.3.4; 4.3.9; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 4.4.7; 5 Srodowisko pracy – oswietlenie awaryjne Czas zalaczania\nZakres (4 – 9000) s\nMetoda pomiarowa bezposrednia PN-EN 1838:2013-11 z wylaczeniem p. 4.2.3; 4.2.4; 4.2.7; 4.3.3; 4.3.4; 4.3.9; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 4.4.7; 5","categories":["environment"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Closing time","parameters_en":[{"name":"Range","range":"(4 – 9000) s"}],"search_en":"Workplace environment – emergency lighting Closing time Direct measurement method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range PN-EN 1838:2013-11 z wyłączeniem p. 4.2.3; 4.2.4; 4.2.7; 4.3.3; 4.3.4; 4.3.9; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 4.4.7; 5","technique_en":"Direct measurement method","test_object_en":"Workplace environment – emergency lighting","parameters_zh":[{"name":"范围","range":"(4 – 9000) s"}],"search_zh":"工作场所环境 — 应急照明 接通时间 直接测量法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 PN-EN 1838:2013-11 z wyłączeniem p. 4.2.3; 4.2.4; 4.2.7; 4.3.3; 4.3.4; 4.3.9; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 4.4.7; 5","technique_zh":"直接测量法","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","test_object_zh":"工作场所环境 — 应急照明","methodology_zh":"接通时间"},{"_id":"6a7d7570441eff5f1564872b","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie awaryjne","methodology":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)","reference":"PN-EN 1838:2013-11 z wyłączeniem p. 4.2.3; 4.2.4; 4.2.7; 4.3.3; 4.3.4; 4.3.9; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 4.4.7; 5","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem p. 4.2.3; 4.2.4; 4.2.7; 4.3.3; 4.3.4; 4.3.9; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 4.4.7; 5"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie awaryjne Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń) PN-EN 1838:2013-11 z wyłączeniem p. 4.2.3; 4.2.4; 4.2.7; 4.3.3; 4.3.4; 4.3.9; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 4.4.7; 5 Srodowisko pracy – oswietlenie awaryjne Stosunek minimalnego do maksymalnego natezenia oswietlenia (z obliczen) PN-EN 1838:2013-11 z wylaczeniem p. 4.2.3; 4.2.4; 4.2.7; 4.3.3; 4.3.4; 4.3.9; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 4.4.7; 5","categories":["environment"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Ratio of minimum to maximum illuminance (calculated)","search_en":"Workplace environment – emergency lighting Ratio of minimum to maximum illuminance (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-EN 1838:2013-11 z wyłączeniem p. 4.2.3; 4.2.4; 4.2.7; 4.3.3; 4.3.4; 4.3.9; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 4.4.7; 5","test_object_en":"Workplace environment – emergency lighting","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","search_zh":"工作场所环境 — 应急照明 最小与最大照度之比（计算值） ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-EN 1838:2013-11 z wyłączeniem p. 4.2.3; 4.2.4; 4.2.7; 4.3.3; 4.3.4; 4.3.9; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 4.4.7; 5","methodology_zh":"最小与最大照度之比（计算值）","test_object_zh":"工作场所环境 — 应急照明"},{"_id":"6a7d7570441eff5f1564872c","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie awaryjne","methodology":"Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń)","reference":"PN-EN 1838:2013-11 z wyłączeniem p. 4.2.3; 4.2.4; 4.2.7; 4.3.3; 4.3.4; 4.3.9; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 4.4.7; 5","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem p. 4.2.3; 4.2.4; 4.2.7; 4.3.3; 4.3.4; 4.3.9; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 4.4.7; 5"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie awaryjne Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń) PN-EN 1838:2013-11 z wyłączeniem p. 4.2.3; 4.2.4; 4.2.7; 4.3.3; 4.3.4; 4.3.9; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 4.4.7; 5 Srodowisko pracy – oswietlenie awaryjne Rownomiernosc oswietlenia dla strefy wysokiego ryzyka (z obliczen) PN-EN 1838:2013-11 z wylaczeniem p. 4.2.3; 4.2.4; 4.2.7; 4.3.3; 4.3.4; 4.3.9; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 4.4.7; 5","categories":["environment"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Illuminance uniformity for the high-risk zone (calculated)","search_en":"Workplace environment – emergency lighting Illuminance uniformity for the high-risk zone (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-EN 1838:2013-11 z wyłączeniem p. 4.2.3; 4.2.4; 4.2.7; 4.3.3; 4.3.4; 4.3.9; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 4.4.7; 5","test_object_en":"Workplace environment – emergency lighting","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","search_zh":"工作场所环境 — 应急照明 高风险区照度均匀度（计算值） ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-EN 1838:2013-11 z wyłączeniem p. 4.2.3; 4.2.4; 4.2.7; 4.3.3; 4.3.4; 4.3.9; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 4.4.7; 5","test_object_zh":"工作场所环境 — 应急照明","methodology_zh":"高风险区照度均匀度（计算值）"},{"_id":"6a7d7570441eff5f1564872d","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – wydatek energetyczny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(5 – 35) °C"},{"name":"Przepływ powietrza"},{"name":"Zakres","range":"(10 – 59) dm3/min"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (5 – 35) °C\nPrzepływ powietrza\nZakres (10 – 59) dm3/min\nMetoda pomiarowa bezpośrednia","reference":"ILR 14 wydanie 1 z dnia 10.07.2018 r.","norm_bases":["ILR 14 wydanie 1 z dnia 10.07.2018 r."],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – wydatek energetyczny Temperatura powietrza\nZakres:\nZakres (5 – 35) °C\nPrzepływ powietrza\nZakres (10 – 59) dm3/min\nMetoda pomiarowa bezpośrednia ILR 14 wydanie 1 z dnia 10.07.2018 r. Srodowisko pracy – wydatek energetyczny Temperatura powietrza\nZakres:\nZakres (5 – 35) °C\nPrzeplyw powietrza\nZakres (10 – 59) dm3/min\nMetoda pomiarowa bezposrednia ILR 14 wydanie 1 z dnia 10.07.2018 r.","categories":["environment"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(5 – 35) °C"},{"name":"Air flow"},{"name":"Range","range":"(10 – 59) dm3/min"}],"search_en":"Workplace environment – energy expenditure Air temperature Direct measurement method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range Air flow Range ILR 14 wydanie 1 z dnia 10.07.2018 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment – energy expenditure","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(5 – 35) °C"},{"name":"空气流量"},{"name":"范围","range":"(10 – 59) dm3/min"}],"search_zh":"工作场所环境 — 能量消耗 空气温度 直接测量法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 空气流量 范围 ILR 14 wydanie 1 z dnia 10.07.2018 r.","technique_zh":"直接测量法","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","test_object_zh":"工作场所环境 — 能量消耗"},{"_id":"6a7d7570441eff5f1564872e","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – wydatek energetyczny","methodology":"Wydatek energetyczny (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wydatek energetyczny (z obliczeń)","reference":"ILR 14 wydanie 1 z dnia 10.07.2018 r.","norm_bases":["ILR 14 wydanie 1 z dnia 10.07.2018 r."],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – wydatek energetyczny Wydatek energetyczny (z obliczeń) ILR 14 wydanie 1 z dnia 10.07.2018 r. Srodowisko pracy – wydatek energetyczny Wydatek energetyczny (z obliczen) ILR 14 wydanie 1 z dnia 10.07.2018 r.","categories":["environment"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Energy expenditure (calculated)","search_en":"Workplace environment – energy expenditure Energy expenditure (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński ILR 14 wydanie 1 z dnia 10.07.2018 r.","test_object_en":"Workplace environment – energy expenditure","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","search_zh":"工作场所环境 — 能量消耗 能量消耗（计算值） ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński ILR 14 wydanie 1 z dnia 10.07.2018 r.","methodology_zh":"能量消耗（计算值）","test_object_zh":"工作场所环境 — 能量消耗"},{"_id":"6a7d7570441eff5f1564872f","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat gorący","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(15 – 60) °C"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(15 – 42) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(15 – 60) °C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (15 – 60) °C\nTemperatura wilgotna naturalna\nZakres (15 – 42) °C\nTemperatura poczernionej kuli\nZakres (15 – 60) °C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (15 – 60) °C\nTemperatura wilgotna naturalna\nZakres (15 – 42) °C\nTemperatura poczernionej kuli\nZakres (15 – 60) °C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 Srodowisko pracy – mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (15 – 60) °C\nTemperatura wilgotna naturalna\nZakres (15 – 42) °C\nTemperatura poczernionej kuli\nZakres (15 – 60) °C\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(15 – 60) °C"},{"name":"Natural wet bulb temperature"},{"name":"Range","range":"(15 – 42) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(15 – 60) °C"}],"search_en":"Workplace environment – hot microclimate Air temperature Direct measurement method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range Natural wet bulb temperature Range Black globe temperature Range PN-EN ISO 7243:2018-01","technique_en":"Direct measurement method","test_object_en":"Workplace environment – hot microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(15 – 60) °C"},{"name":"自然湿球温度"},{"name":"范围","range":"(15 – 42) °C"},{"name":"黑球温度"},{"name":"范围","range":"(15 – 60) °C"}],"search_zh":"工作场所环境 — 高温微气候 空气温度 直接测量法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 自然湿球温度 范围 黑球温度 范围 PN-EN ISO 7243:2018-01","technique_zh":"直接测量法","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a7d7570441eff5f15648730","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat gorący","methodology":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat gorący Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01 Srodowisko pracy – mikroklimat goracy Wskaznik WBGT, Wskaznik WBGTeff (z obliczen) PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"WBGT index, WBGTeff index (calculated)","search_en":"Workplace environment – hot microclimate WBGT index, WBGTeff index (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-EN ISO 7243:2018-01","test_object_en":"Workplace environment – hot microclimate","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_zh":"WBGT 指数、WBGTeff 指数（计算值）","search_zh":"工作场所环境 — 高温微气候 WBGT 指数、WBGTeff 指数（计算值） ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-EN ISO 7243:2018-01","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a7d7570441eff5f15648731","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat umiarkowany","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(10 – 42) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 – 42) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(13 – 85) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 1,5) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 – 42) °C\nTemperatura poczernionej kuli\nZakres (10 – 42) °C\nWilgotność powietrza\nZakres (13 – 85) %\nPrędkość powietrza\nZakres (0,15 – 1,5) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006","norm_bases":["PN-EN ISO 7730:2006"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 – 42) °C\nTemperatura poczernionej kuli\nZakres (10 – 42) °C\nWilgotność powietrza\nZakres (13 – 85) %\nPrędkość powietrza\nZakres (0,15 – 1,5) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006 Srodowisko pracy – mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 – 42) °C\nTemperatura poczernionej kuli\nZakres (10 – 42) °C\nWilgotnosc powietrza\nZakres (13 – 85) %\nPredkosc powietrza\nZakres (0,15 – 1,5) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006","categories":["environment"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(10 – 42) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10 – 42) °C"},{"name":"Air humidity"},{"name":"Range","range":"(13 – 85) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 – 1,5) m/s"}],"search_en":"Workplace environment – moderate microclimate Air temperature Direct measurement method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 7730:2006","technique_en":"Direct measurement method","test_object_en":"Workplace environment – moderate microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 – 42) °C"},{"name":"黑球温度"},{"name":"范围","range":"(10 – 42) °C"},{"name":"空气湿度"},{"name":"范围","range":"(13 – 85) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 1,5) m/s"}],"search_zh":"工作场所环境 — 中等微气候 空气温度 直接测量法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 7730:2006","technique_zh":"直接测量法","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a7d7570441eff5f15648732","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat umiarkowany","methodology":"Wskaźnik PMV i PPD (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik PMV i PPD (z obliczeń)","reference":"PN-EN ISO 7730:2006","norm_bases":["PN-EN ISO 7730:2006"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat umiarkowany Wskaźnik PMV i PPD (z obliczeń) PN-EN ISO 7730:2006 Srodowisko pracy – mikroklimat umiarkowany Wskaznik PMV i PPD (z obliczen) PN-EN ISO 7730:2006","categories":["environment"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"PMV and PPD index (calculated)","search_en":"Workplace environment – moderate microclimate PMV and PPD index (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-EN ISO 7730:2006","test_object_en":"Workplace environment – moderate microclimate","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","search_zh":"工作场所环境 — 中等微气候 PMV 与 PPD 指数（由计算得出） ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-EN ISO 7730:2006","test_object_zh":"工作场所环境 — 中等微气候","methodology_zh":"PMV 与 PPD 指数（由计算得出）"},{"_id":"6a7d7570441eff5f15648733","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat zimny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(-29 – 10) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(-29 – 15) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(13,0 – 85,0) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 5,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (-29 – 10) °C\nTemperatura poczernionej kuli\nZakres (-29 – 15) °C\nWilgotność powietrza\nZakres (13,0 – 85,0) %\nPrędkość powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-29 – 10) °C\nTemperatura poczernionej kuli\nZakres (-29 – 15) °C\nWilgotność powietrza\nZakres (13,0 – 85,0) %\nPrędkość powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 11079:2008 Srodowisko pracy – mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-29 – 10) °C\nTemperatura poczernionej kuli\nZakres (-29 – 15) °C\nWilgotnosc powietrza\nZakres (13,0 – 85,0) %\nPredkosc powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 11079:2008","categories":["environment"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(-29 – 10) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(-29 – 15) °C"},{"name":"Air humidity"},{"name":"Range","range":"(13,0 – 85,0) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 – 5,0) m/s"}],"search_en":"Workplace environment – cold microclimate Air temperature Direct measurement method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 11079:2008","technique_en":"Direct measurement method","test_object_en":"Workplace environment – cold microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(-29 – 10) °C"},{"name":"黑球温度"},{"name":"范围","range":"(-29 – 15) °C"},{"name":"空气湿度"},{"name":"范围","range":"(13,0 – 85,0) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 5,0) m/s"}],"search_zh":"工作场所环境 — 低温微气候 空气温度 直接测量法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 11079:2008","technique_zh":"直接测量法","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","test_object_zh":"工作场所环境 — 低温微气候"},{"_id":"6a7d7570441eff5f15648734","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat zimny","methodology":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat zimny Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń) PN-EN ISO 11079:2008 Srodowisko pracy – mikroklimat zimny Wskaznik IREQmin, Wskaznik IREQneutral, Wskaznik twc (z obliczen) PN-EN ISO 11079:2008","categories":["environment"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"IREQmin index, IREQneutral index, twc index (calculated)","search_en":"Workplace environment – cold microclimate IREQmin index, IREQneutral index, twc index (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-EN ISO 11079:2008","test_object_en":"Workplace environment – cold microclimate","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","search_zh":"工作场所环境 — 低温微气候 IREQmin 指数、IREQneutral 指数、twc 指数（计算值） ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-EN ISO 11079:2008","test_object_zh":"工作场所环境 — 低温微气候","methodology_zh":"IREQmin 指数、IREQneutral 指数、twc 指数（计算值）"},{"_id":"6a7d7570441eff5f15648735","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,3 – 100) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,3 – 100) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,3 – 100) m/s2\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,3 – 100) m/s2\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,3 – 100) m/s2"}],"search_en":"Workplace environment – hand-arm vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – hand-arm vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,3 – 100) m/s2"}],"search_zh":"工作场所环境 — 手传振动 频率计权振动加速度有效值 直接测量法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 手传振动","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński"},{"_id":"6a7d7570441eff5f15648736","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated)","search_en":"Workplace environment – hand-arm vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_en":"Workplace environment – hand-arm vibration","search_zh":"工作场所环境 — 手传振动 日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值） ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_zh":"工作场所环境 — 手传振动","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_zh":"日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值）"},{"_id":"6a7d7570441eff5f15648737","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,03 – 35,5) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,03 – 35,5) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,03 – 35,5) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,03 – 35,5) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,03 – 35,5) m/s2"}],"search_en":"Workplace environment – whole-body vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range PN-EN 14253+A1:2011","technique_en":"Direct measurement method","test_object_en":"Workplace environment – whole-body vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,03 – 35,5) m/s2"}],"search_zh":"工作场所环境 — 全身振动 频率计权振动加速度有效值 直接测量法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 PN-EN 14253+A1:2011","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 全身振动","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński"},{"_id":"6a7d7570441eff5f15648738","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz) (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated)","search_en":"Workplace environment – whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-EN 14253+A1:2011","test_object_en":"Workplace environment – whole-body vibration","search_zh":"工作场所环境 — 全身振动 日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值） ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-EN 14253+A1:2011","test_object_zh":"工作场所环境 — 全身振动","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_zh":"日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值）"},{"_id":"6a7d7570441eff5f15648739","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(30 – 135) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(60 – 138) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (30 – 135) dB\nSzczytowy poziom dźwięku C\nZakres (60 – 138) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 3 - p. 11","norm_bases":["PN-N-01307:1994","PN-ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 3 - p. 11"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (30 – 135) dB\nSzczytowy poziom dźwięku C\nZakres (60 – 138) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 3 - p. 11 Srodowisko pracy – halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (30 – 135) dB\nSzczytowy poziom dzwieku C\nZakres (60 – 138) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-ISO 9612:2025-11 z wylaczeniem metody obejmujacej Strategie 3 - p. 11","categories":["environment"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(30 – 135) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(60 – 138) dB"}],"search_en":"Workplace environment – noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 3 - p. 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(30 – 135) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(60 – 138) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 3 - p. 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński"},{"_id":"6a7d7570441eff5f1564873a","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godzinnego dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 3 - p. 11","norm_bases":["PN-N-01307:1994","PN-ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 3 - p. 11"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 3 - p. 11 Srodowisko pracy – halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-ISO 9612:2025-11 z wylaczeniem metody obejmujacej Strategie 3 - p. 11","categories":["environment"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment – noise Noise exposure level referred to: ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 3 - p. 11","test_object_en":"Workplace environment – noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 3 - p. 11","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński"},{"_id":"6a7d7570441eff5f1564873b","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – hałas ultradźwiękowy","methodology":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 do 40 kHz Maksymalne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych do 10 do 40 kHz","parameters":[{"name":"Zakres","range":"(40 – 140) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 do 40 kHz Maksymalne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych do 10 do 40 kHz\nZakres (40 – 140) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-Z-01339:2020-12","norm_bases":["PN-Z-01339:2020-12"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas ultradźwiękowy Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 do 40 kHz Maksymalne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych do 10 do 40 kHz\nZakres (40 – 140) dB\nMetoda pomiarowa bezpośrednia PN-Z-01339:2020-12 Srodowisko pracy – halas ultradzwiekowy Rownowazne poziomy cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 do 40 kHz Maksymalne poziomy cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych do 10 do 40 kHz\nZakres (40 – 140) dB\nMetoda pomiarowa bezposrednia PN-Z-01339:2020-12","categories":["environment"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Equivalent sound pressure levels in one-third octave bands with centre frequencies from 10 to 40 kHz Maximum sound pressure levels in one-third octave bands with centre frequencies from 10 to 40 kHz","parameters_en":[{"name":"Range","range":"(40 – 140) dB"}],"search_en":"Workplace environment – ultrasonic noise Equivalent sound pressure levels in one-third octave bands with centre frequencies from 10 to 40 kHz Maximum sound pressure levels in one-third octave bands with centre frequencies from 10 to 40 kHz Direct measurement method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range PN-Z-01339:2020-12","technique_en":"Direct measurement method","test_object_en":"Workplace environment – ultrasonic noise","parameters_zh":[{"name":"范围","range":"(40 – 140) dB"}],"search_zh":"工作场所环境 — 超声噪声 直接测量法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 PN-Z-01339:2020-12","technique_zh":"直接测量法","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","test_object_zh":"工作场所环境 — 超声噪声"},{"_id":"6a7d7570441eff5f1564873c","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko pracy – hałas ultradźwiękowy","methodology":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 do 40 kHz odniesiony do:","parameters":[{"name":"8-godzinnego dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 do 40 kHz odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-Z-01339:2020-12","norm_bases":["PN-Z-01339:2020-12"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas ultradźwiękowy Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 do 40 kHz odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-Z-01339:2020-12 Srodowisko pracy – halas ultradzwiekowy Rownowazne poziomy cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 do 40 kHz odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-Z-01339:2020-12","categories":["environment"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Equivalent sound pressure levels in one-third octave bands with centre frequencies from 10 to 40 kHz referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment – ultrasonic noise Equivalent sound pressure levels in one-third octave bands with centre frequencies from 10 to 40 kHz referred to: ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński an 8-hour daily working time the average weekly working time (calculated) PN-Z-01339:2020-12","test_object_en":"Workplace environment – ultrasonic noise","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 超声噪声 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 8 小时日工作时间 平均每周工作时间（计算值） PN-Z-01339:2020-12","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","test_object_zh":"工作场所环境 — 超声噪声"},{"_id":"6a7d7570441eff5f1564873d","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(24 – 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (24 – 135) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (24 – 135) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (24 – 135) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(24 – 135) dB"}],"search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","technique_en":"Direct measurement method","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(24 – 135) dB"}],"search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 A 计权等效声级 直接测量法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","technique_zh":"直接测量法","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński"},{"_id":"6a7d7570441eff5f1564873e","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński"},{"_id":"6a7d7570441eff5f1564873f","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa","parameters":[{"name":"Prędkość:"},{"name":"Zakres","range":"(0,1 – 30) m/s"}],"technique":"Metoda spiętrzenia; Metoda termoanemometryczna","techniques":["Metoda spiętrzenia","Metoda termoanemometryczna"],"computed":[],"activity":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa\nZakres:\nPrędkość:\nZakres (0,1 – 30) m/s\nMetoda spiętrzenia; Metoda termoanemometryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa\nZakres:\nPrędkość:\nZakres (0,1 – 30) m/s\nMetoda spiętrzenia; Metoda termoanemometryczna PN-Z-04030-7:1994 Gazy odlotowe Strumien objetosci gazu dla cisnien dynamicznych > 10 Pa\nZakres:\nPredkosc:\nZakres (0,1 – 30) m/s\nMetoda spietrzenia; Metoda termoanemometryczna PN-Z-04030-7:1994","categories":["other"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Gas volume flow rate for dynamic pressures > 10 Pa","parameters_en":[{"name":"Velocity:"},{"name":"Range","range":"(0,1 – 30) m/s"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Gas volume flow rate for dynamic pressures > 10 Pa Stagnation pressure method; Thermoanemometric method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Velocity: Range PN-Z-04030-7:1994","technique_en":"Stagnation pressure method; Thermoanemometric method","test_object_en":"Waste gases","parameters_zh":[{"name":"Prędkość:"},{"name":"范围","range":"(0,1 – 30) m/s"}],"search_zh":"废气 动压 > 10 Pa 时的气体体积流量 皮托管法；热线风速仪法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-Z-04030-7:1994","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"动压 > 10 Pa 时的气体体积流量","technique_zh":"皮托管法；热线风速仪法"},{"_id":"6a7d7570441eff5f15648740","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-Z-04030-7:1994 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-Z-04030-7:1994","categories":["other"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Sampling for determination of dust concentration","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for determination of dust concentration ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-Z-04030-7:1994","test_object_en":"Waste gases","search_zh":"废气 粉尘浓度测定采样 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-Z-04030-7:1994","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_zh":"粉尘浓度测定采样","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a7d7570441eff5f15648741","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"(0,001 – 70) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu\nZakres (0,001 – 70) g/m3\nMetoda grawimetryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (0,001 – 70) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 Gazy odlotowe Stezenie pylu\nZakres (0,001 – 70) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994","categories":["other"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"(0,001 – 70) g/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Dust concentration Gravimetric method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range PN-Z-04030-7:1994","technique_en":"Gravimetric method","test_object_en":"Waste gases","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,001 – 70) g/m3"}],"search_zh":"废气 粉尘浓度 重量法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-Z-04030-7:1994","technique_zh":"重量法","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a7d7570441eff5f15648742","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja pyłu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-Z-04030-7:1994 Gazy odlotowe Emisja pylu (z obliczen) PN-Z-04030-7:1994","categories":["environment"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Dust emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Dust emission (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-Z-04030-7:1994","test_object_en":"Waste gases","search_zh":"废气 粉尘排放量（计算值） ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-Z-04030-7:1994","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_zh":"粉尘排放量（计算值）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a7d7570441eff5f15648743","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-EN 13284-1:2018-02 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-EN 13284-1:2018-02","categories":["other"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Sampling for determination of dust concentration","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for determination of dust concentration ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 13284-1:2018-02","test_object_en":"Waste gases","search_zh":"废气 粉尘浓度测定采样 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 13284-1:2018-02","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_zh":"粉尘浓度测定采样","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a7d7570441eff5f15648744","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"(0,0001 – 0,050) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu\nZakres (0,0001 – 0,050) g/m3\nMetoda grawimetryczna","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (0,0001 – 0,050) g/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02 Gazy odlotowe Stezenie pylu\nZakres (0,0001 – 0,050) g/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02","categories":["other"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"(0,0001 – 0,050) g/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Dust concentration Gravimetric method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range PN-EN 13284-1:2018-02","technique_en":"Gravimetric method","test_object_en":"Waste gases","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,0001 – 0,050) g/m3"}],"search_zh":"废气 粉尘浓度 重量法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-EN 13284-1:2018-02","technique_zh":"重量法","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a7d7570441eff5f15648745","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja pyłu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-EN 13284-1:2018-02 Gazy odlotowe Emisja pylu (z obliczen) PN-EN 13284-1:2018-02","categories":["environment"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Dust emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Dust emission (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 13284-1:2018-02","test_object_en":"Waste gases","search_zh":"废气 粉尘排放量（计算值） ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 13284-1:2018-02","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_zh":"粉尘排放量（计算值）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a7d7570441eff5f15648746","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenu, dwutlenku siarki, tlenku węgla, dwutlenku węgla","parameters":[{"name":"O2","range":"(2,0 – 21) %"},{"name":"SO2","range":"(2,86 – 3000) mg/m3"},{"name":"CO2","range":"(0,1 – 15) %"}],"technique":"Metoda elektrochemiczna; Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda elektrochemiczna","Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenie tlenu, dwutlenku siarki, tlenku węgla, dwutlenku węgla\nZakres:\nO2 (2,0 – 21) %\nSO2 (2,86 – 3000) mg/m3\nCO2 (0,1 – 15) %\nMetoda elektrochemiczna; Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie tlenu, dwutlenku siarki, tlenku węgla, dwutlenku węgla\nZakres:\nO2 (2,0 – 21) %\nSO2 (2,86 – 3000) mg/m3\nCO2 (0,1 – 15) %\nMetoda elektrochemiczna; Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001 Gazy odlotowe Stezenie tlenu, dwutlenku siarki, tlenku wegla, dwutlenku wegla\nZakres:\nO2 (2,0 – 21) %\nSO2 (2,86 – 3000) mg/m3\nCO2 (0,1 – 15) %\nMetoda elektrochemiczna; Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001","categories":["other"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Concentration of oxygen, sulphur dioxide, carbon monoxide, carbon dioxide","parameters_en":[{"name":"O2","range":"(2,0 – 21) %"},{"name":"SO2","range":"(2,86 – 3000) mg/m3"},{"name":"CO2","range":"(0,1 – 15) %"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Concentration of oxygen, sulphur dioxide, carbon monoxide, carbon dioxide Electrochemical method; Non-dispersive infrared spectrometry (NDIR) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law O2 SO2 CO2 PN-ISO 10396:2001","technique_en":"Electrochemical method; Non-dispersive infrared spectrometry (NDIR)","test_object_en":"Waste gases","search_zh":"废气 电化学法；非分散红外光谱法（NDIR） ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 O2 SO2 CO2 PN-ISO 10396:2001","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","parameters_zh":[{"name":"O2","range":"(2,0 – 21) %"},{"name":"SO2","range":"(2,86 – 3000) mg/m3"},{"name":"CO2","range":"(0,1 – 15) %"}],"regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","technique_zh":"电化学法；非分散红外光谱法（NDIR）"},{"_id":"6a7d7570441eff5f15648747","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja SO2, CO2 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja SO2, CO2 (z obliczeń)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja SO2, CO2 (z obliczeń) PN-ISO 10396:2001 Gazy odlotowe Emisja SO2, CO2 (z obliczen) PN-ISO 10396:2001","categories":["environment"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Emission of SO2, CO2 (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Emission of SO2, CO2 (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-ISO 10396:2001","test_object_en":"Waste gases","search_zh":"废气 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-ISO 10396:2001","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a7d7570441eff5f15648748","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenków azotu","parameters":[{"name":"NOx","range":"(2,0 – 2000) mg/m3"}],"technique":"Metoda chemiluminescencyjna (CLD)","techniques":["Metoda chemiluminescencyjna (CLD)"],"computed":[],"activity":"Stężenie tlenków azotu\nNOx (2,0 – 2000) mg/m3\nMetoda chemiluminescencyjna (CLD)","reference":"PN-EN 14792:2017-04 | PN-ISO 10396:2001","norm_bases":["PN-EN 14792:2017-04","PN-ISO 10396:2001"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie tlenków azotu\nNOx (2,0 – 2000) mg/m3\nMetoda chemiluminescencyjna (CLD) PN-EN 14792:2017-04 | PN-ISO 10396:2001 Gazy odlotowe Stezenie tlenkow azotu\nNOx (2,0 – 2000) mg/m3\nMetoda chemiluminescencyjna (CLD) PN-EN 14792:2017-04 | PN-ISO 10396:2001","categories":["other"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Nitrogen oxides concentration","parameters_en":[{"name":"NOx","range":"(2,0 – 2000) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Nitrogen oxides concentration Chemiluminescence method (CLD) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law NOx PN-EN 14792:2017-04 | PN-ISO 10396:2001","technique_en":"Chemiluminescence method (CLD)","test_object_en":"Waste gases","search_zh":"废气 氮氧化物浓度 化学发光法（CLD） ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 NOx PN-EN 14792:2017-04 | PN-ISO 10396:2001","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","parameters_zh":[{"name":"NOx","range":"(2,0 – 2000) mg/m3"}],"regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","technique_zh":"化学发光法（CLD）","methodology_zh":"氮氧化物浓度"},{"_id":"6a7d7570441eff5f15648749","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja NOx (NO i NO2 w przeliczeniu na NO2) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja NOx (NO i NO2 w przeliczeniu na NO2) (z obliczeń)","reference":"PN-EN 14792:2017-04 | PN-ISO 10396:2001","norm_bases":["PN-EN 14792:2017-04","PN-ISO 10396:2001"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja NOx (NO i NO2 w przeliczeniu na NO2) (z obliczeń) PN-EN 14792:2017-04 | PN-ISO 10396:2001 Gazy odlotowe Emisja NOx (NO i NO2 w przeliczeniu na NO2) (z obliczen) PN-EN 14792:2017-04 | PN-ISO 10396:2001","categories":["environment"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"NOx emission (NO and NO2 expressed as NO2) (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases NOx emission (NO and NO2 expressed as NO2) (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 14792:2017-04 | PN-ISO 10396:2001","test_object_en":"Waste gases","search_zh":"废气 NOx 排放（NO 与 NO2 以 NO2 计）（由计算得出） ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 14792:2017-04 | PN-ISO 10396:2001","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"NOx 排放（NO 与 NO2 以 NO2 计）（由计算得出）"},{"_id":"6a7d7570441eff5f1564874a","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenku węgla","parameters":[{"name":"CO","range":"(1,25 – 3750) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenie tlenku węgla\nCO (1,25 – 3750) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN 15058:2017-04 | PN-ISO 10396:2001","norm_bases":["PN-EN 15058:2017-04","PN-ISO 10396:2001"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie tlenku węgla\nCO (1,25 – 3750) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15058:2017-04 | PN-ISO 10396:2001 Gazy odlotowe Stezenie tlenku wegla\nCO (1,25 – 3750) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15058:2017-04 | PN-ISO 10396:2001","categories":["other"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Carbon monoxide concentration","parameters_en":[{"name":"CO","range":"(1,25 – 3750) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Carbon monoxide concentration Non-dispersive infrared spectrometry (NDIR) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law CO PN-EN 15058:2017-04 | PN-ISO 10396:2001","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"Waste gases","search_zh":"废气 一氧化碳浓度 非分散红外光谱法（NDIR） ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 CO PN-EN 15058:2017-04 | PN-ISO 10396:2001","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_zh":"一氧化碳浓度","parameters_zh":[{"name":"CO","range":"(1,25 – 3750) mg/m3"}],"technique_zh":"非分散红外光谱法（NDIR）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a7d7570441eff5f1564874b","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja CO (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja CO (z obliczeń)","reference":"PN-EN 15058:2017-04 | PN-ISO 10396:2001","norm_bases":["PN-EN 15058:2017-04","PN-ISO 10396:2001"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja CO (z obliczeń) PN-EN 15058:2017-04 | PN-ISO 10396:2001 Gazy odlotowe Emisja CO (z obliczen) PN-EN 15058:2017-04 | PN-ISO 10396:2001","categories":["environment"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"CO emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases CO emission (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 15058:2017-04 | PN-ISO 10396:2001","test_object_en":"Waste gases","search_zh":"废气 CO 排放量（计算值） ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 15058:2017-04 | PN-ISO 10396:2001","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"CO 排放量（计算值）"},{"_id":"6a7d7570441eff5f1564874c","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia chlorowodoru","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia chlorowodoru","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia chlorowodoru PN-EN 1911:2011 Gazy odlotowe Pobieranie probek do oznaczania stezenia chlorowodoru PN-EN 1911:2011","categories":["other"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Sampling for determination of hydrogen chloride concentration","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for determination of hydrogen chloride concentration ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 1911:2011","test_object_en":"Waste gases","search_zh":"废气 氯化氢浓度测定采样 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 1911:2011","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"氯化氢浓度测定采样"},{"_id":"6a7d7570441eff5f1564874d","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie chlorowodoru","parameters":[{"name":"Zakres","range":"(0,08 – 75) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chlorowodoru\nZakres (0,08 – 75) mg/m3\nMetoda spektrofotometryczna","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie chlorowodoru\nZakres (0,08 – 75) mg/m3\nMetoda spektrofotometryczna PN-EN 1911:2011 Gazy odlotowe Stezenie chlorowodoru\nZakres (0,08 – 75) mg/m3\nMetoda spektrofotometryczna PN-EN 1911:2011","categories":["other"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Hydrogen chloride concentration","parameters_en":[{"name":"Range","range":"(0,08 – 75) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Hydrogen chloride concentration Spectrophotometric method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range PN-EN 1911:2011","technique_en":"Spectrophotometric method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,08 – 75) mg/m3"}],"search_zh":"废气 氯化氢浓度 分光光度法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-EN 1911:2011","technique_zh":"分光光度法","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"氯化氢浓度"},{"_id":"6a7d7570441eff5f1564874e","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja HCl (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja HCl (z obliczeń)","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja HCl (z obliczeń) PN-EN 1911:2011 Gazy odlotowe Emisja HCl (z obliczen) PN-EN 1911:2011","categories":["environment"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"HCl emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases HCl emission (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 1911:2011","test_object_en":"Waste gases","search_zh":"废气 HCl 排放（由计算得出） ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 1911:2011","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"HCl 排放（由计算得出）"},{"_id":"6a7d7570441eff5f1564874f","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia fluorowodoru","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia fluorowodoru","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia fluorowodoru ISO 15713:2006 Gazy odlotowe Pobieranie probek do oznaczania stezenia fluorowodoru ISO 15713:2006","categories":["other"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Sampling for determination of hydrogen fluoride concentration","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for determination of hydrogen fluoride concentration ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law ISO 15713:2006","test_object_en":"Waste gases","search_zh":"废气 氟化氢浓度测定采样 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 ISO 15713:2006","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"氟化氢浓度测定采样"},{"_id":"6a7d7570441eff5f15648750","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie fluorowodoru","parameters":[{"name":"Zakres","range":"(0,02 – 100) mg/m3"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Stężenie fluorowodoru\nZakres (0,02 – 100) mg/m3\nMetoda potencjometryczna","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie fluorowodoru\nZakres (0,02 – 100) mg/m3\nMetoda potencjometryczna ISO 15713:2006 Gazy odlotowe Stezenie fluorowodoru\nZakres (0,02 – 100) mg/m3\nMetoda potencjometryczna ISO 15713:2006","categories":["other"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Hydrogen fluoride concentration","parameters_en":[{"name":"Range","range":"(0,02 – 100) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Hydrogen fluoride concentration Potentiometric method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range ISO 15713:2006","technique_en":"Potentiometric method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,02 – 100) mg/m3"}],"search_zh":"废气 氟化氢浓度 电位法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 ISO 15713:2006","technique_zh":"电位法","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"氟化氢浓度"},{"_id":"6a7d7570441eff5f15648751","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja HF (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja HF (z obliczeń)","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja HF (z obliczeń) ISO 15713:2006 Gazy odlotowe Emisja HF (z obliczen) ISO 15713:2006","categories":["environment"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"HF emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases HF emission (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law ISO 15713:2006","test_object_en":"Waste gases","search_zh":"废气 HF 排放量（计算值） ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 ISO 15713:2006","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"HF 排放量（计算值）"},{"_id":"6a7d7570441eff5f15648752","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej","reference":"PN-EN 13211+AC:2006","norm_bases":["PN-EN 13211+AC:2006"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia rtęci ogólnej PN-EN 13211+AC:2006 Gazy odlotowe Pobieranie probek do oznaczania stezenia rteci ogolnej PN-EN 13211+AC:2006","categories":["other"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Sampling for determination of total mercury concentration","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for determination of total mercury concentration ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 13211+AC:2006","test_object_en":"Waste gases","search_zh":"废气 总汞浓度测定采样 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 13211+AC:2006","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"总汞浓度测定采样"},{"_id":"6a7d7570441eff5f15648753","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja rtęci ogólnej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja rtęci ogólnej (z obliczeń)","reference":"PN-EN 13211+AC:2006","norm_bases":["PN-EN 13211+AC:2006"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja rtęci ogólnej (z obliczeń) PN-EN 13211+AC:2006 Gazy odlotowe Emisja rteci ogolnej (z obliczen) PN-EN 13211+AC:2006","categories":["environment"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Total mercury emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Total mercury emission (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 13211+AC:2006","test_object_en":"Waste gases","search_zh":"废气 总汞排放量（计算值） ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 13211+AC:2006","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"总汞排放量（计算值）"},{"_id":"6a7d7570441eff5f15648754","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V","reference":"PN-EN 14385:2005","norm_bases":["PN-EN 14385:2005"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V PN-EN 14385:2005 Gazy odlotowe Pobieranie probek do oznaczania stezenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V PN-EN 14385:2005","categories":["materials"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 14385:2005","test_object_en":"Waste gases","search_zh":"废气 用于测定金属浓度的采样：As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 14385:2005","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"用于测定金属浓度的采样：As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V"},{"_id":"6a7d7570441eff5f15648755","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń)","reference":"PN-EN 14385:2005","norm_bases":["PN-EN 14385:2005"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń) PN-EN 14385:2005 Gazy odlotowe Emisja metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczen) PN-EN 14385:2005","categories":["materials","environment"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Emission of metals: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Emission of metals: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 14385:2005","test_object_en":"Waste gases","search_zh":"废气 金属排放：As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V（由计算得出） ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 14385:2005","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"金属排放：As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V（由计算得出）"},{"_id":"6a7d7570441eff5f15648756","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia związków organicznych","parameters":[],"technique":"Metoda aspiracyjna z zastosowaniem węgla aktywnego/ żelu krzemionkowego/ roztworów pochłaniających","techniques":["Metoda aspiracyjna z zastosowaniem węgla aktywnego/ żelu krzemionkowego/ roztworów pochłaniających"],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia związków organicznych\nMetoda aspiracyjna z zastosowaniem węgla aktywnego/ żelu krzemionkowego/ roztworów pochłaniających","reference":"PN-Z-04008-4:1999","norm_bases":["PN-Z-04008-4:1999"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia związków organicznych\nMetoda aspiracyjna z zastosowaniem węgla aktywnego/ żelu krzemionkowego/ roztworów pochłaniających PN-Z-04008-4:1999 Gazy odlotowe Pobieranie probek do oznaczania stezenia zwiazkow organicznych\nMetoda aspiracyjna z zastosowaniem wegla aktywnego/ zelu krzemionkowego/ roztworow pochlaniajacych PN-Z-04008-4:1999","categories":["other"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Sampling for the determination of organic compound concentration","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for the determination of organic compound concentration Aspiration method using activated carbon/ silica gel/ absorbing solutions ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-Z-04008-4:1999","technique_en":"Aspiration method using activated carbon/ silica gel/ absorbing solutions","test_object_en":"Waste gases","search_zh":"废气 用于测定有机化合物浓度的采样 使用活性炭/硅胶/吸收液的抽气采样法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-Z-04008-4:1999","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"用于测定有机化合物浓度的采样","technique_zh":"使用活性炭/硅胶/吸收液的抽气采样法"},{"_id":"6a7d7570441eff5f15648757","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja związków organicznych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja związków organicznych (z obliczeń)","reference":"PN-Z-04008-4:1999","norm_bases":["PN-Z-04008-4:1999"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja związków organicznych (z obliczeń) PN-Z-04008-4:1999 Gazy odlotowe Emisja zwiazkow organicznych (z obliczen) PN-Z-04008-4:1999","categories":["environment"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Emission of organic compounds (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Emission of organic compounds (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-Z-04008-4:1999","test_object_en":"Waste gases","search_zh":"废气 有机化合物排放量（计算值） ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-Z-04008-4:1999","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_zh":"有机化合物排放量（计算值）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a7d7570441eff5f15648758","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania dwutlenku siarki","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania dwutlenku siarki","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania dwutlenku siarki PN-EN 14791:2017-04 Gazy odlotowe Pobieranie probek do oznaczania dwutlenku siarki PN-EN 14791:2017-04","categories":["other"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Sampling for determination of sulfur dioxide","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for determination of sulfur dioxide ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 14791:2017-04","test_object_en":"Waste gases","search_zh":"废气 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 14791:2017-04","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a7d7570441eff5f15648759","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie dwutlenku siarki","parameters":[{"name":"Zakres","range":"(2,0 – 2000) mg/m3"}],"technique":"Metoda toronowa","techniques":["Metoda toronowa"],"computed":[],"activity":"Stężenie dwutlenku siarki\nZakres (2,0 – 2000) mg/m3\nMetoda toronowa","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie dwutlenku siarki\nZakres (2,0 – 2000) mg/m3\nMetoda toronowa PN-EN 14791:2017-04 Gazy odlotowe Stezenie dwutlenku siarki\nZakres (2,0 – 2000) mg/m3\nMetoda toronowa PN-EN 14791:2017-04","categories":["other"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Sulphur dioxide concentration","parameters_en":[{"name":"Range","range":"(2,0 – 2000) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sulphur dioxide concentration Thoron method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range PN-EN 14791:2017-04","technique_en":"Thoron method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(2,0 – 2000) mg/m3"}],"search_zh":"废气 二氧化硫浓度 钍射气法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-EN 14791:2017-04","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","technique_zh":"钍射气法","methodology_zh":"二氧化硫浓度"},{"_id":"6a7d7570441eff5f1564875a","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja dwutlenku siarki (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja dwutlenku siarki (z obliczeń)","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja dwutlenku siarki (z obliczeń) PN-EN 14791:2017-04 Gazy odlotowe Emisja dwutlenku siarki (z obliczen) PN-EN 14791:2017-04","categories":["environment"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Sulphur dioxide emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sulphur dioxide emission (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 14791:2017-04","test_object_en":"Waste gases","search_zh":"废气 二氧化硫排放（由计算得出） ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 14791:2017-04","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"二氧化硫排放（由计算得出）"},{"_id":"6a7d7570441eff5f1564875b","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/m3"}],"technique":"Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","techniques":["Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)"],"computed":[],"activity":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (2,0 – 1000) mg/m3\nMetoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","reference":"PN-EN 12619:2013-05","norm_bases":["PN-EN 12619:2013-05"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (2,0 – 1000) mg/m3\nMetoda ciągłej detekcji płomieniowo-jonizacyjnej (FID) PN-EN 12619:2013-05 Gazy odlotowe Stezenie substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny\nZakres (2,0 – 1000) mg/m3\nMetoda ciaglej detekcji plomieniowo-jonizacyjnej (FID) PN-EN 12619:2013-05","categories":["other"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon","parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Continuous flame ionization detection method (FID) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range PN-EN 12619:2013-05","technique_en":"Continuous flame ionization detection method (FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/m3"}],"search_zh":"废气 以总气态有机碳表示的气态与蒸气态有机物浓度 连续火焰离子化检测法（FID） ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-EN 12619:2013-05","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物浓度","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","technique_zh":"连续火焰离子化检测法（FID）"},{"_id":"6a7d7570441eff5f1564875c","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń)","reference":"PN-EN 12619:2013-05","norm_bases":["PN-EN 12619:2013-05"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń) PN-EN 12619:2013-05 Gazy odlotowe Emisja substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny (z obliczen) PN-EN 12619:2013-05","categories":["environment"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 12619:2013-05","test_object_en":"Waste gases","search_zh":"废气 以总气态有机碳表示的气态与蒸气态有机物排放量（计算值） ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 12619:2013-05","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物排放量（计算值）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a7d7570441eff5f1564875d","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia PCDD/PCDF","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia PCDD/PCDF","reference":"PN-EN 1948-1:2006","norm_bases":["PN-EN 1948-1:2006"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia PCDD/PCDF PN-EN 1948-1:2006 Gazy odlotowe Pobieranie probek do oznaczania stezenia PCDD/PCDF PN-EN 1948-1:2006","categories":["other"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Sampling for the determination of PCDD/PCDF concentration","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for the determination of PCDD/PCDF concentration ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 1948-1:2006","test_object_en":"Waste gases","search_zh":"废气 用于测定 PCDD/PCDF 浓度的采样 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 1948-1:2006","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"用于测定 PCDD/PCDF 浓度的采样"},{"_id":"6a7d7570441eff5f1564875e","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja PCDD/PCDF (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja PCDD/PCDF (z obliczeń)","reference":"PN-EN 1948-1:2006","norm_bases":["PN-EN 1948-1:2006"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja PCDD/PCDF (z obliczeń) PN-EN 1948-1:2006 Gazy odlotowe Emisja PCDD/PCDF (z obliczen) PN-EN 1948-1:2006","categories":["environment"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"PCDD/PCDF emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases PCDD/PCDF emission (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 1948-1:2006","test_object_en":"Waste gases","search_zh":"废气 PCDD/PCDF 排放（由计算得出） ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 1948-1:2006","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"PCDD/PCDF 排放（由计算得出）"},{"_id":"6a7d7570441eff5f1564875f","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia pyłu PM 2,5 i PM 10","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu PM 2,5 i PM 10","reference":"PN-EN ISO 23210:2010","norm_bases":["PN-EN ISO 23210:2010"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PM 2,5 i PM 10 PN-EN ISO 23210:2010 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PM 2,5 i PM 10 PN-EN ISO 23210:2010","categories":["other"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Sampling for determination of the concentration of PM 2,5 and PM 10 dust","search_en":"Waste gases Sampling for determination of the concentration of PM 2,5 and PM 10 dust ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-EN ISO 23210:2010","test_object_en":"Waste gases","search_zh":"废气 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-EN ISO 23210:2010","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński"},{"_id":"6a7d7570441eff5f15648760","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie pyłu PM 2,5 i PM 10","parameters":[{"name":"Zakres","range":"(0,6 – 40) mg/m3"}],"technique":"Metoda impakcyjna","techniques":["Metoda impakcyjna"],"computed":[],"activity":"Stężenie pyłu PM 2,5 i PM 10\nZakres (0,6 – 40) mg/m3\nMetoda impakcyjna","reference":"PN-EN ISO 23210:2010","norm_bases":["PN-EN ISO 23210:2010"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie pyłu PM 2,5 i PM 10\nZakres (0,6 – 40) mg/m3\nMetoda impakcyjna PN-EN ISO 23210:2010 Gazy odlotowe Stezenie pylu PM 2,5 i PM 10\nZakres (0,6 – 40) mg/m3\nMetoda impakcyjna PN-EN ISO 23210:2010","categories":["other"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"PM 2,5 and PM 10 dust concentration","parameters_en":[{"name":"Range","range":"(0,6 – 40) mg/m3"}],"search_en":"Waste gases PM 2,5 and PM 10 dust concentration Impaction method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range PN-EN ISO 23210:2010","technique_en":"Impaction method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,6 – 40) mg/m3"}],"search_zh":"废气 PM 2,5 与 PM 10 粉尘浓度 撞击法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 PN-EN ISO 23210:2010","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","technique_zh":"撞击法","methodology_zh":"PM 2,5 与 PM 10 粉尘浓度"},{"_id":"6a7d7570441eff5f15648761","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja pyłu PM 2,5 i PM 10 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja pyłu PM 2,5 i PM 10 (z obliczeń)","reference":"PN-EN ISO 23210:2010","norm_bases":["PN-EN ISO 23210:2010"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja pyłu PM 2,5 i PM 10 (z obliczeń) PN-EN ISO 23210:2010 Gazy odlotowe Emisja pylu PM 2,5 i PM 10 (z obliczen) PN-EN ISO 23210:2010","categories":["environment"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"PM 2,5 and PM 10 dust emission (calculated)","search_en":"Waste gases PM 2,5 and PM 10 dust emission (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-EN ISO 23210:2010","test_object_en":"Waste gases","search_zh":"废气 PM 2,5 与 PM 10 粉尘排放（由计算得出） ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-EN ISO 23210:2010","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_zh":"PM 2,5 与 PM 10 粉尘排放（由计算得出）"},{"_id":"6a7d7570441eff5f15648762","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia metali: Sb, As, Ba, Cr, Zn, Sn, Al, Cd, Co, Mn, Cu, Mo, Ni, Pb, Ti, Ag, V, Fe, Bi, K, Li, Na, Se","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia metali: Sb, As, Ba, Cr, Zn, Sn, Al, Cd, Co, Mn, Cu, Mo, Ni, Pb, Ti, Ag, V, Fe, Bi, K, Li, Na, Se","reference":"ILR 34 wydanie 1 z dnia 04.04.2014 r.","norm_bases":["ILR 34 wydanie 1 z dnia 04.04.2014 r."],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia metali: Sb, As, Ba, Cr, Zn, Sn, Al, Cd, Co, Mn, Cu, Mo, Ni, Pb, Ti, Ag, V, Fe, Bi, K, Li, Na, Se ILR 34 wydanie 1 z dnia 04.04.2014 r. Gazy odlotowe Pobieranie probek do oznaczania stezenia metali: Sb, As, Ba, Cr, Zn, Sn, Al, Cd, Co, Mn, Cu, Mo, Ni, Pb, Ti, Ag, V, Fe, Bi, K, Li, Na, Se ILR 34 wydanie 1 z dnia 04.04.2014 r.","categories":["materials"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Sampling for determination of metal concentrations: Sb, As, Ba, Cr, Zn, Sn, Al, Cd, Co, Mn, Cu, Mo, Ni, Pb, Ti, Ag, V, Fe, Bi, K, Li, Na, Se","search_en":"Waste gases Sampling for determination of metal concentrations: Sb, As, Ba, Cr, Zn, Sn, Al, Cd, Co, Mn, Cu, Mo, Ni, Pb, Ti, Ag, V, Fe, Bi, K, Li, Na, Se ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński ILR 34 wydanie 1 z dnia 04.04.2014 r.","test_object_en":"Waste gases","search_zh":"废气 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński ILR 34 wydanie 1 z dnia 04.04.2014 r.","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński"},{"_id":"6a7d7570441eff5f15648763","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja metali: Sb, As, Ba, Cr, Zn, Sn, Al, Cd, Co, Mn, Cu, Mo, Ni, Pb, Ti, Ag, V, Fe, Bi, K, Li, Na, Se (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja metali: Sb, As, Ba, Cr, Zn, Sn, Al, Cd, Co, Mn, Cu, Mo, Ni, Pb, Ti, Ag, V, Fe, Bi, K, Li, Na, Se (z obliczeń)","reference":"ILR 34 wydanie 1 z dnia 04.04.2014 r.","norm_bases":["ILR 34 wydanie 1 z dnia 04.04.2014 r."],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja metali: Sb, As, Ba, Cr, Zn, Sn, Al, Cd, Co, Mn, Cu, Mo, Ni, Pb, Ti, Ag, V, Fe, Bi, K, Li, Na, Se (z obliczeń) ILR 34 wydanie 1 z dnia 04.04.2014 r. Gazy odlotowe Emisja metali: Sb, As, Ba, Cr, Zn, Sn, Al, Cd, Co, Mn, Cu, Mo, Ni, Pb, Ti, Ag, V, Fe, Bi, K, Li, Na, Se (z obliczen) ILR 34 wydanie 1 z dnia 04.04.2014 r.","categories":["materials","environment"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Emission of metals: Sb, As, Ba, Cr, Zn, Sn, Al, Cd, Co, Mn, Cu, Mo, Ni, Pb, Ti, Ag, V, Fe, Bi, K, Li, Na, Se (calculated)","search_en":"Waste gases Emission of metals: Sb, As, Ba, Cr, Zn, Sn, Al, Cd, Co, Mn, Cu, Mo, Ni, Pb, Ti, Ag, V, Fe, Bi, K, Li, Na, Se (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński ILR 34 wydanie 1 z dnia 04.04.2014 r.","test_object_en":"Waste gases","search_zh":"废气 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński ILR 34 wydanie 1 z dnia 04.04.2014 r.","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński"},{"_id":"6a7d7570441eff5f15648764","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia amoniaku, chloru, cyjanowodoru, kwasu siarkowego, siarkowodoru, ozonu","parameters":[],"technique":"Metoda aspiracyjna z zastosowaniem roztworów pochłaniających i filtrów membranowych","techniques":["Metoda aspiracyjna z zastosowaniem roztworów pochłaniających i filtrów membranowych"],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia amoniaku, chloru, cyjanowodoru, kwasu siarkowego, siarkowodoru, ozonu\nMetoda aspiracyjna z zastosowaniem roztworów pochłaniających i filtrów membranowych","reference":"ILR 33 wydanie 7 z dnia 12.12.2022 r.","norm_bases":["ILR 33 wydanie 7 z dnia 12.12.2022 r."],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia amoniaku, chloru, cyjanowodoru, kwasu siarkowego, siarkowodoru, ozonu\nMetoda aspiracyjna z zastosowaniem roztworów pochłaniających i filtrów membranowych ILR 33 wydanie 7 z dnia 12.12.2022 r. Gazy odlotowe Pobieranie probek do oznaczania stezenia amoniaku, chloru, cyjanowodoru, kwasu siarkowego, siarkowodoru, ozonu\nMetoda aspiracyjna z zastosowaniem roztworow pochlaniajacych i filtrow membranowych ILR 33 wydanie 7 z dnia 12.12.2022 r.","categories":["other"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Sampling for determination of the concentration of ammonia, chlorine, hydrogen cyanide, sulfuric acid, hydrogen sulfide, ozone","search_en":"Waste gases Sampling for determination of the concentration of ammonia, chlorine, hydrogen cyanide, sulfuric acid, hydrogen sulfide, ozone Aspiration method using absorbing solutions and membrane filters ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński ILR 33 wydanie 7 z dnia 12.12.2022 r.","technique_en":"Aspiration method using absorbing solutions and membrane filters","test_object_en":"Waste gases","search_zh":"废气 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński ILR 33 wydanie 7 z dnia 12.12.2022 r.","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński"},{"_id":"6a7d7570441eff5f15648765","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja amoniaku, chloru, cyjanowodoru, kwasu siarkowego, siarkowodoru, ozonu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja amoniaku, chloru, cyjanowodoru, kwasu siarkowego, siarkowodoru, ozonu (z obliczeń)","reference":"ILR 33 wydanie 7 z dnia 12.12.2022 r.","norm_bases":["ILR 33 wydanie 7 z dnia 12.12.2022 r."],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja amoniaku, chloru, cyjanowodoru, kwasu siarkowego, siarkowodoru, ozonu (z obliczeń) ILR 33 wydanie 7 z dnia 12.12.2022 r. Gazy odlotowe Emisja amoniaku, chloru, cyjanowodoru, kwasu siarkowego, siarkowodoru, ozonu (z obliczen) ILR 33 wydanie 7 z dnia 12.12.2022 r.","categories":["environment"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Emission of ammonia, chlorine, hydrogen cyanide, sulphuric acid, hydrogen sulphide, ozone (calculated)","search_en":"Waste gases Emission of ammonia, chlorine, hydrogen cyanide, sulphuric acid, hydrogen sulphide, ozone (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński ILR 33 wydanie 7 z dnia 12.12.2022 r.","test_object_en":"Waste gases","search_zh":"废气 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński ILR 33 wydanie 7 z dnia 12.12.2022 r.","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński"},{"_id":"6a7d7570441eff5f15648766","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia PCB typu dioksyn (dioksyny i furany)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia PCB typu dioksyn (dioksyny i furany)","reference":"PN-EN 1948-4:2013+A1:2014-03","norm_bases":["PN-EN 1948-4:2013+A1:2014-03"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia PCB typu dioksyn (dioksyny i furany) PN-EN 1948-4:2013+A1:2014-03 Gazy odlotowe Pobieranie probek do oznaczania stezenia PCB typu dioksyn (dioksyny i furany) PN-EN 1948-4:2013+A1:2014-03","categories":["other"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Sampling for determination of the concentration of dioxin-like PCB (dioxins and furans)","search_en":"Waste gases Sampling for determination of the concentration of dioxin-like PCB (dioxins and furans) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-EN 1948-4:2013+A1:2014-03","test_object_en":"Waste gases","search_zh":"废气 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-EN 1948-4:2013+A1:2014-03","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński"},{"_id":"6a7d7570441eff5f15648767","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja PCB typu dioksyn (dioksyny i furany) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja PCB typu dioksyn (dioksyny i furany) (z obliczeń)","reference":"PN-EN 1948-4:2013+A1:2014-03","norm_bases":["PN-EN 1948-4:2013+A1:2014-03"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja PCB typu dioksyn (dioksyny i furany) (z obliczeń) PN-EN 1948-4:2013+A1:2014-03 Gazy odlotowe Emisja PCB typu dioksyn (dioksyny i furany) (z obliczen) PN-EN 1948-4:2013+A1:2014-03","categories":["environment"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Emission of dioxin-like PCBs (dioxins and furans) (calculated)","search_en":"Waste gases Emission of dioxin-like PCBs (dioxins and furans) (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-EN 1948-4:2013+A1:2014-03","test_object_en":"Waste gases","search_zh":"废气 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-EN 1948-4:2013+A1:2014-03","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński"},{"_id":"6a7d7570441eff5f15648768","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia amoniaku","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia amoniaku","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia amoniaku PN-EN ISO 21877:2020-03 Gazy odlotowe Pobieranie probek do oznaczania stezenia amoniaku PN-EN ISO 21877:2020-03","categories":["other"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Sampling for determination of ammonia concentration","search_en":"Waste gases Sampling for determination of ammonia concentration ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-EN ISO 21877:2020-03","test_object_en":"Waste gases","search_zh":"废气 氨浓度测定采样 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-EN ISO 21877:2020-03","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_zh":"氨浓度测定采样"},{"_id":"6a7d7570441eff5f15648769","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość amoniaku","parameters":[{"name":"Zakres","range":"(0,08 – 83) mg/m3"},{"name":"Zakres","range":"(0,005 – 2,5) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość amoniaku\nZakres:\nZakres (0,08 – 83) mg/m3\nZakres (0,005 – 2,5) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość amoniaku\nZakres:\nZakres (0,08 – 83) mg/m3\nZakres (0,005 – 2,5) mg w próbce\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03 Gazy odlotowe Stezenie/zawartosc amoniaku\nZakres:\nZakres (0,08 – 83) mg/m3\nZakres (0,005 – 2,5) mg w probce\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03","categories":["other"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Ammonia concentration/content","parameters_en":[{"name":"Range","range":"(0,08 – 83) mg/m3"},{"name":"Range","range":"(0,005 – 2,5) mg w próbce"}],"search_en":"Waste gases Ammonia concentration/content Spectrophotometric method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range Range PN-EN ISO 21877:2020-03","technique_en":"Spectrophotometric method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,08 – 83) mg/m3"},{"name":"范围","range":"(0,005 – 2,5) mg w próbce"}],"search_zh":"废气 氨浓度/含量 分光光度法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 范围 PN-EN ISO 21877:2020-03","technique_zh":"分光光度法","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_zh":"氨浓度/含量"},{"_id":"6a7d7570441eff5f1564876a","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja amoniaku (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja amoniaku (z obliczeń)","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja amoniaku (z obliczeń) PN-EN ISO 21877:2020-03 Gazy odlotowe Emisja amoniaku (z obliczen) PN-EN ISO 21877:2020-03","categories":["environment"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Ammonia emission (calculated)","search_en":"Waste gases Ammonia emission (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-EN ISO 21877:2020-03","test_object_en":"Waste gases","search_zh":"废气 氨排放量（计算值） ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-EN ISO 21877:2020-03","test_object_zh":"废气","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_zh":"氨排放量（计算值）"},{"_id":"6a7d7570441eff5f1564876b","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe, Środowisko ogólne – próbki gazów odlotowych","methodology":"Pobieranie próbek do oznaczania stężenia fluoru","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia fluoru","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Środowisko ogólne – próbki gazów odlotowych Pobieranie próbek do oznaczania stężenia fluoru ISO 15713:2006 Gazy odlotowe, Srodowisko ogolne – probki gazow odlotowych Pobieranie probek do oznaczania stezenia fluoru ISO 15713:2006","categories":["environment"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Sampling for the determination of fluorine concentration","search_en":"Waste gases, General environment – waste gas samples Sampling for the determination of fluorine concentration ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński ISO 15713:2006","test_object_en":"Waste gases, General environment – waste gas samples","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","search_zh":"排放气体、一般环境 － 排放气体样品 用于测定氟浓度的采样 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński ISO 15713:2006","test_object_zh":"排放气体、一般环境 － 排放气体样品","methodology_zh":"用于测定氟浓度的采样"},{"_id":"6a7d7570441eff5f1564876c","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe, Środowisko ogólne – próbki gazów odlotowych","methodology":"Stężenie/zawartość fluoru","parameters":[{"name":"Zakres","range":"(0,02– 100,00) mg/m3"},{"name":"Zakres","range":"(0,002 – 10,00) mg w próbce"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Stężenie/zawartość fluoru\nZakres:\nZakres (0,02– 100,00) mg/m3\nZakres (0,002 – 10,00) mg w próbce\nMetoda potencjometryczna","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Środowisko ogólne – próbki gazów odlotowych Stężenie/zawartość fluoru\nZakres:\nZakres (0,02– 100,00) mg/m3\nZakres (0,002 – 10,00) mg w próbce\nMetoda potencjometryczna ISO 15713:2006 Gazy odlotowe, Srodowisko ogolne – probki gazow odlotowych Stezenie/zawartosc fluoru\nZakres:\nZakres (0,02– 100,00) mg/m3\nZakres (0,002 – 10,00) mg w probce\nMetoda potencjometryczna ISO 15713:2006","categories":["environment"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Concentration/content of fluorine","parameters_en":[{"name":"Range","range":"(0,02– 100,00) mg/m3"},{"name":"Range","range":"(0,002 – 10,00) mg w próbce"}],"search_en":"Waste gases, General environment – waste gas samples Concentration/content of fluorine Potentiometric method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range Range ISO 15713:2006","technique_en":"Potentiometric method","test_object_en":"Waste gases, General environment – waste gas samples","parameters_zh":[{"name":"范围","range":"(0,02– 100,00) mg/m3"},{"name":"范围","range":"(0,002 – 10,00) mg w próbce"}],"search_zh":"排放气体、一般环境 － 排放气体样品 电位法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 范围 ISO 15713:2006","technique_zh":"电位法","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","test_object_zh":"排放气体、一般环境 － 排放气体样品"},{"_id":"6a7d7570441eff5f1564876d","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe, Środowisko ogólne – próbki gazów odlotowych","methodology":"Emisja fluoru (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja fluoru (z obliczeń)","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Środowisko ogólne – próbki gazów odlotowych Emisja fluoru (z obliczeń) ISO 15713:2006 Gazy odlotowe, Srodowisko ogolne – probki gazow odlotowych Emisja fluoru (z obliczen) ISO 15713:2006","categories":["environment"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Fluorine emission (calculated)","search_en":"Waste gases, General environment – waste gas samples Fluorine emission (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński ISO 15713:2006","test_object_en":"Waste gases, General environment – waste gas samples","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","search_zh":"排放气体、一般环境 － 排放气体样品 氟排放（由计算得出） ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński ISO 15713:2006","test_object_zh":"排放气体、一般环境 － 排放气体样品","methodology_zh":"氟排放（由计算得出）"},{"_id":"6a7d7570441eff5f1564876e","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe, Środowisko ogólne – próbki gazów odlotowych","methodology":"Stężenie/zawartość cyjanowodoru i cyjanków w przeliczeniu na CN-","parameters":[{"name":"Zakres","range":"(0,02 – 33,33) mg/m3"},{"name":"Zakres","range":"(0,0005 – 0,1) mg w próbce"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Stężenie/zawartość cyjanowodoru i cyjanków w przeliczeniu na CN-\nZakres:\nZakres (0,02 – 33,33) mg/m3\nZakres (0,0005 – 0,1) mg w próbce\nMetoda potencjometryczna","reference":"PN-70/Z-04053 z wyłączeniem pkt. 7 | ILR 16 wydanie 1 z dn. 01.03.2021 r.","norm_bases":["PN-70/Z-04053 z wyłączeniem pkt. 7","ILR 16 wydanie 1 z dn. 01.03.2021 r."],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Środowisko ogólne – próbki gazów odlotowych Stężenie/zawartość cyjanowodoru i cyjanków w przeliczeniu na CN-\nZakres:\nZakres (0,02 – 33,33) mg/m3\nZakres (0,0005 – 0,1) mg w próbce\nMetoda potencjometryczna PN-70/Z-04053 z wyłączeniem pkt. 7 | ILR 16 wydanie 1 z dn. 01.03.2021 r. Gazy odlotowe, Srodowisko ogolne – probki gazow odlotowych Stezenie/zawartosc cyjanowodoru i cyjankow w przeliczeniu na CN-\nZakres:\nZakres (0,02 – 33,33) mg/m3\nZakres (0,0005 – 0,1) mg w probce\nMetoda potencjometryczna PN-70/Z-04053 z wylaczeniem pkt. 7 | ILR 16 wydanie 1 z dn. 01.03.2021 r.","categories":["environment"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Concentration/content of hydrogen cyanide and cyanides calculated as CN-","parameters_en":[{"name":"Range","range":"(0,02 – 33,33) mg/m3"},{"name":"Range","range":"(0,0005 – 0,1) mg w próbce"}],"search_en":"Waste gases, General environment – waste gas samples Concentration/content of hydrogen cyanide and cyanides calculated as CN- Potentiometric method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range Range PN-70/Z-04053 z wyłączeniem pkt. 7 | ILR 16 wydanie 1 z dn. 01.03.2021 r.","technique_en":"Potentiometric method","test_object_en":"Waste gases, General environment – waste gas samples","parameters_zh":[{"name":"范围","range":"(0,02 – 33,33) mg/m3"},{"name":"范围","range":"(0,0005 – 0,1) mg w próbce"}],"search_zh":"排放气体、一般环境 － 排放气体样品 电位法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 范围 PN-70/Z-04053 z wyłączeniem pkt. 7 | ILR 16 wydanie 1 z dn. 01.03.2021 r.","technique_zh":"电位法","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","test_object_zh":"排放气体、一般环境 － 排放气体样品"},{"_id":"6a7d7570441eff5f1564876f","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe, Środowisko ogólne – próbki gazów odlotowych","methodology":"Stężenie/zawartość tlenku azotu","parameters":[{"name":"Zakres","range":"(0,07– 23,11) mg/m3"},{"name":"Zakres","range":"(0,0013-0,0104) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość tlenku azotu\nZakres:\nZakres (0,07– 23,11) mg/m3\nZakres (0,0013-0,0104) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04009-11:2008 z wyłączeniem pkt. 7","norm_bases":["PN-Z-04009-11:2008 z wyłączeniem pkt. 7"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Środowisko ogólne – próbki gazów odlotowych Stężenie/zawartość tlenku azotu\nZakres:\nZakres (0,07– 23,11) mg/m3\nZakres (0,0013-0,0104) mg w próbce\nMetoda spektrofotometryczna PN-Z-04009-11:2008 z wyłączeniem pkt. 7 Gazy odlotowe, Srodowisko ogolne – probki gazow odlotowych Stezenie/zawartosc tlenku azotu\nZakres:\nZakres (0,07– 23,11) mg/m3\nZakres (0,0013-0,0104) mg w probce\nMetoda spektrofotometryczna PN-Z-04009-11:2008 z wylaczeniem pkt. 7","categories":["environment"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Nitrogen monoxide concentration/content","parameters_en":[{"name":"Range","range":"(0,07– 23,11) mg/m3"},{"name":"Range","range":"(0,0013-0,0104) mg w próbce"}],"search_en":"Waste gases, General environment – waste gas samples Nitrogen monoxide concentration/content Spectrophotometric method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range Range PN-Z-04009-11:2008 z wyłączeniem pkt. 7","technique_en":"Spectrophotometric method","test_object_en":"Waste gases, General environment – waste gas samples","parameters_zh":[{"name":"范围","range":"(0,07– 23,11) mg/m3"},{"name":"范围","range":"(0,0013-0,0104) mg w próbce"}],"search_zh":"排放气体、一般环境 － 排放气体样品 一氧化氮的浓度/含量 分光光度法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 范围 PN-Z-04009-11:2008 z wyłączeniem pkt. 7","technique_zh":"分光光度法","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_zh":"一氧化氮的浓度/含量","test_object_zh":"排放气体、一般环境 － 排放气体样品"},{"_id":"6a7d7570441eff5f15648770","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe, Środowisko ogólne – próbki gazów odlotowych","methodology":"Stężenie/zawartość ditlenku azotu","parameters":[{"name":"Zakres","range":"(0,02 – 7,11) mg/m3"},{"name":"Zakres","range":"(0,0004 – 0,016) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość ditlenku azotu\nZakres:\nZakres (0,02 – 7,11) mg/m3\nZakres (0,0004 – 0,016) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04009-11:2008 z wyłączeniem pkt. 7","norm_bases":["PN-Z-04009-11:2008 z wyłączeniem pkt. 7"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Środowisko ogólne – próbki gazów odlotowych Stężenie/zawartość ditlenku azotu\nZakres:\nZakres (0,02 – 7,11) mg/m3\nZakres (0,0004 – 0,016) mg w próbce\nMetoda spektrofotometryczna PN-Z-04009-11:2008 z wyłączeniem pkt. 7 Gazy odlotowe, Srodowisko ogolne – probki gazow odlotowych Stezenie/zawartosc ditlenku azotu\nZakres:\nZakres (0,02 – 7,11) mg/m3\nZakres (0,0004 – 0,016) mg w probce\nMetoda spektrofotometryczna PN-Z-04009-11:2008 z wylaczeniem pkt. 7","categories":["environment"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Nitrogen dioxide concentration/content","parameters_en":[{"name":"Range","range":"(0,02 – 7,11) mg/m3"},{"name":"Range","range":"(0,0004 – 0,016) mg w próbce"}],"search_en":"Waste gases, General environment – waste gas samples Nitrogen dioxide concentration/content Spectrophotometric method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range Range PN-Z-04009-11:2008 z wyłączeniem pkt. 7","technique_en":"Spectrophotometric method","test_object_en":"Waste gases, General environment – waste gas samples","parameters_zh":[{"name":"范围","range":"(0,02 – 7,11) mg/m3"},{"name":"范围","range":"(0,0004 – 0,016) mg w próbce"}],"search_zh":"排放气体、一般环境 － 排放气体样品 二氧化氮的浓度/含量 分光光度法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 范围 PN-Z-04009-11:2008 z wyłączeniem pkt. 7","technique_zh":"分光光度法","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_zh":"二氧化氮的浓度/含量","test_object_zh":"排放气体、一般环境 － 排放气体样品"},{"_id":"6a7d7570441eff5f15648771","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe, Środowisko ogólne – próbki gazów odlotowych","methodology":"Stężenie/zawartość amoniaku","parameters":[{"name":"Zakres","range":"(1,3 – 450) mg/m3"},{"name":"Zakres","range":"(0,02 – 2,25) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość amoniaku\nZakres:\nZakres (1,3 – 450) mg/m3\nZakres (0,02 – 2,25) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-71/Z-04041 z wyłączeniem pkt. 7","norm_bases":["PN-71/Z-04041 z wyłączeniem pkt. 7"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Środowisko ogólne – próbki gazów odlotowych Stężenie/zawartość amoniaku\nZakres:\nZakres (1,3 – 450) mg/m3\nZakres (0,02 – 2,25) mg w próbce\nMetoda spektrofotometryczna PN-71/Z-04041 z wyłączeniem pkt. 7 Gazy odlotowe, Srodowisko ogolne – probki gazow odlotowych Stezenie/zawartosc amoniaku\nZakres:\nZakres (1,3 – 450) mg/m3\nZakres (0,02 – 2,25) mg w probce\nMetoda spektrofotometryczna PN-71/Z-04041 z wylaczeniem pkt. 7","categories":["environment"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Ammonia concentration/content","parameters_en":[{"name":"Range","range":"(1,3 – 450) mg/m3"},{"name":"Range","range":"(0,02 – 2,25) mg w próbce"}],"search_en":"Waste gases, General environment – waste gas samples Ammonia concentration/content Spectrophotometric method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range Range PN-71/Z-04041 z wyłączeniem pkt. 7","technique_en":"Spectrophotometric method","test_object_en":"Waste gases, General environment – waste gas samples","parameters_zh":[{"name":"范围","range":"(1,3 – 450) mg/m3"},{"name":"范围","range":"(0,02 – 2,25) mg w próbce"}],"search_zh":"排放气体、一般环境 － 排放气体样品 氨浓度/含量 分光光度法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 范围 PN-71/Z-04041 z wyłączeniem pkt. 7","technique_zh":"分光光度法","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_zh":"氨浓度/含量","test_object_zh":"排放气体、一般环境 － 排放气体样品"},{"_id":"6a7d7570441eff5f15648772","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe, Środowisko ogólne – próbki gazów odlotowych","methodology":"Stężenie/zawartość kwasu siarkowego (VI) i tritlenku siarki","parameters":[{"name":"Zakres","range":"(0,1 – 20) mg/m3"},{"name":"Zakres","range":"(0,1 – 10) mg w próbce"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"computed":[],"activity":"Stężenie/zawartość kwasu siarkowego (VI) i tritlenku siarki\nZakres:\nZakres (0,1 – 20) mg/m3\nZakres (0,1 – 10) mg w próbce\nMetoda turbidymetryczna","reference":"PN-91/Z-04056.02 z wyłączeniem pkt. 7","norm_bases":["PN-91/Z-04056.02 z wyłączeniem pkt. 7"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Środowisko ogólne – próbki gazów odlotowych Stężenie/zawartość kwasu siarkowego (VI) i tritlenku siarki\nZakres:\nZakres (0,1 – 20) mg/m3\nZakres (0,1 – 10) mg w próbce\nMetoda turbidymetryczna PN-91/Z-04056.02 z wyłączeniem pkt. 7 Gazy odlotowe, Srodowisko ogolne – probki gazow odlotowych Stezenie/zawartosc kwasu siarkowego (VI) i tritlenku siarki\nZakres:\nZakres (0,1 – 20) mg/m3\nZakres (0,1 – 10) mg w probce\nMetoda turbidymetryczna PN-91/Z-04056.02 z wylaczeniem pkt. 7","categories":["environment"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Concentration/content of sulfuric(VI) acid and sulfur trioxide","parameters_en":[{"name":"Range","range":"(0,1 – 20) mg/m3"},{"name":"Range","range":"(0,1 – 10) mg w próbce"}],"search_en":"Waste gases, General environment – waste gas samples Concentration/content of sulfuric(VI) acid and sulfur trioxide Turbidimetric method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range Range PN-91/Z-04056.02 z wyłączeniem pkt. 7","technique_en":"Turbidimetric method","test_object_en":"Waste gases, General environment – waste gas samples","parameters_zh":[{"name":"范围","range":"(0,1 – 20) mg/m3"},{"name":"范围","range":"(0,1 – 10) mg w próbce"}],"search_zh":"排放气体、一般环境 － 排放气体样品 浊度法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 范围 PN-91/Z-04056.02 z wyłączeniem pkt. 7","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","technique_zh":"浊度法","test_object_zh":"排放气体、一般环境 － 排放气体样品"},{"_id":"6a7d7570441eff5f15648773","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe, Środowisko ogólne – próbki gazów odlotowych","methodology":"Stężenie/zawartość chromu (VI)","parameters":[{"name":"Zakres","range":"(0,01 – 1,60) mg/m3"},{"name":"Zakres","range":"(0,002 – 0,08) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość chromu (VI)\nZakres:\nZakres (0,01 – 1,60) mg/m3\nZakres (0,002 – 0,08) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-87/Z-04126.03 z wyłączeniem pkt. 7","norm_bases":["PN-87/Z-04126.03 z wyłączeniem pkt. 7"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Środowisko ogólne – próbki gazów odlotowych Stężenie/zawartość chromu (VI)\nZakres:\nZakres (0,01 – 1,60) mg/m3\nZakres (0,002 – 0,08) mg w próbce\nMetoda spektrofotometryczna PN-87/Z-04126.03 z wyłączeniem pkt. 7 Gazy odlotowe, Srodowisko ogolne – probki gazow odlotowych Stezenie/zawartosc chromu (VI)\nZakres:\nZakres (0,01 – 1,60) mg/m3\nZakres (0,002 – 0,08) mg w probce\nMetoda spektrofotometryczna PN-87/Z-04126.03 z wylaczeniem pkt. 7","categories":["environment"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Concentration/content of chromium (VI)","parameters_en":[{"name":"Range","range":"(0,01 – 1,60) mg/m3"},{"name":"Range","range":"(0,002 – 0,08) mg w próbce"}],"search_en":"Waste gases, General environment – waste gas samples Concentration/content of chromium (VI) Spectrophotometric method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range Range PN-87/Z-04126.03 z wyłączeniem pkt. 7","technique_en":"Spectrophotometric method","test_object_en":"Waste gases, General environment – waste gas samples","parameters_zh":[{"name":"范围","range":"(0,01 – 1,60) mg/m3"},{"name":"范围","range":"(0,002 – 0,08) mg w próbce"}],"search_zh":"排放气体、一般环境 － 排放气体样品 分光光度法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 范围 PN-87/Z-04126.03 z wyłączeniem pkt. 7","technique_zh":"分光光度法","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","test_object_zh":"排放气体、一般环境 － 排放气体样品"},{"_id":"6a7d7570441eff5f15648774","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe, Środowisko ogólne – próbki gazów odlotowych","methodology":"Stężenie/zawartość formaldehydu","parameters":[{"name":"Zakres","range":"(0,03 – 10,0) mg/m3"},{"name":"Zakres","range":"(0,0005 – 0,20) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość formaldehydu\nZakres:\nZakres (0,03 – 10,0) mg/m3\nZakres (0,0005 – 0,20) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-76/Z-04045.04 z wyłączeniem pkt. 7","norm_bases":["PN-76/Z-04045.04 z wyłączeniem pkt. 7"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Środowisko ogólne – próbki gazów odlotowych Stężenie/zawartość formaldehydu\nZakres:\nZakres (0,03 – 10,0) mg/m3\nZakres (0,0005 – 0,20) mg w próbce\nMetoda spektrofotometryczna PN-76/Z-04045.04 z wyłączeniem pkt. 7 Gazy odlotowe, Srodowisko ogolne – probki gazow odlotowych Stezenie/zawartosc formaldehydu\nZakres:\nZakres (0,03 – 10,0) mg/m3\nZakres (0,0005 – 0,20) mg w probce\nMetoda spektrofotometryczna PN-76/Z-04045.04 z wylaczeniem pkt. 7","categories":["environment"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Formaldehyde concentration/content","parameters_en":[{"name":"Range","range":"(0,03 – 10,0) mg/m3"},{"name":"Range","range":"(0,0005 – 0,20) mg w próbce"}],"search_en":"Waste gases, General environment – waste gas samples Formaldehyde concentration/content Spectrophotometric method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range Range PN-76/Z-04045.04 z wyłączeniem pkt. 7","technique_en":"Spectrophotometric method","test_object_en":"Waste gases, General environment – waste gas samples","parameters_zh":[{"name":"范围","range":"(0,03 – 10,0) mg/m3"},{"name":"范围","range":"(0,0005 – 0,20) mg w próbce"}],"search_zh":"排放气体、一般环境 － 排放气体样品 甲醛浓度/含量 分光光度法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 范围 PN-76/Z-04045.04 z wyłączeniem pkt. 7","technique_zh":"分光光度法","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_zh":"甲醛浓度/含量","test_object_zh":"排放气体、一般环境 － 排放气体样品"},{"_id":"6a7d7570441eff5f15648775","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Gazy odlotowe, Środowisko ogólne – próbki gazów odlotowych","methodology":"Stężenie/zawartość ozonu","parameters":[{"name":"Zakres","range":"(0,01 – 0,25) mg/m3"},{"name":"Zakres","range":"(0,001 – 0,01) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość ozonu\nZakres:\nZakres (0,01 – 0,25) mg/m3\nZakres (0,001 – 0,01) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04007-2:1994 z wyłączeniem pkt. 7","norm_bases":["PN-Z-04007-2:1994 z wyłączeniem pkt. 7"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Środowisko ogólne – próbki gazów odlotowych Stężenie/zawartość ozonu\nZakres:\nZakres (0,01 – 0,25) mg/m3\nZakres (0,001 – 0,01) mg w próbce\nMetoda spektrofotometryczna PN-Z-04007-2:1994 z wyłączeniem pkt. 7 Gazy odlotowe, Srodowisko ogolne – probki gazow odlotowych Stezenie/zawartosc ozonu\nZakres:\nZakres (0,01 – 0,25) mg/m3\nZakres (0,001 – 0,01) mg w probce\nMetoda spektrofotometryczna PN-Z-04007-2:1994 z wylaczeniem pkt. 7","categories":["environment"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Ozone concentration/content","parameters_en":[{"name":"Range","range":"(0,01 – 0,25) mg/m3"},{"name":"Range","range":"(0,001 – 0,01) mg w próbce"}],"search_en":"Waste gases, General environment – waste gas samples Ozone concentration/content Spectrophotometric method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range Range PN-Z-04007-2:1994 z wyłączeniem pkt. 7","technique_en":"Spectrophotometric method","test_object_en":"Waste gases, General environment – waste gas samples","parameters_zh":[{"name":"范围","range":"(0,01 – 0,25) mg/m3"},{"name":"范围","range":"(0,001 – 0,01) mg w próbce"}],"search_zh":"排放气体、一般环境 － 排放气体样品 臭氧的浓度/含量 分光光度法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 范围 PN-Z-04007-2:1994 z wyłączeniem pkt. 7","technique_zh":"分光光度法","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_zh":"臭氧的浓度/含量","test_object_zh":"排放气体、一般环境 － 排放气体样品"},{"_id":"6a7d7570441eff5f15648776","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych","methodology":"Zawartość chlorowodoru","parameters":[{"name":"Zakres","range":"(0,017 – 7,50) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość chlorowodoru\nZakres (0,017 – 7,50) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki gazów odlotowych Zawartość chlorowodoru\nZakres (0,017 – 7,50) mg w próbce\nMetoda spektrofotometryczna PN-EN 1911:2011 Srodowisko ogolne – probki gazow odlotowych Zawartosc chlorowodoru\nZakres (0,017 – 7,50) mg w probce\nMetoda spektrofotometryczna PN-EN 1911:2011","categories":["environment"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Hydrogen chloride content","parameters_en":[{"name":"Range","range":"(0,017 – 7,50) mg w próbce"}],"search_en":"General environment – waste gas samples Hydrogen chloride content Spectrophotometric method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range PN-EN 1911:2011","technique_en":"Spectrophotometric method","test_object_en":"General environment – waste gas samples","parameters_zh":[{"name":"范围","range":"(0,017 – 7,50) mg w próbce"}],"search_zh":"氯化氢含量 分光光度法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 PN-EN 1911:2011","technique_zh":"分光光度法","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_zh":"氯化氢含量"},{"_id":"6a7d7570441eff5f15648777","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych","methodology":"Zawartość fluorowodoru","parameters":[{"name":"Zakres","range":"(0,002 – 10,00) mg w próbce"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Zawartość fluorowodoru\nZakres (0,002 – 10,00) mg w próbce\nMetoda potencjometryczna","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki gazów odlotowych Zawartość fluorowodoru\nZakres (0,002 – 10,00) mg w próbce\nMetoda potencjometryczna ISO 15713:2006 Srodowisko ogolne – probki gazow odlotowych Zawartosc fluorowodoru\nZakres (0,002 – 10,00) mg w probce\nMetoda potencjometryczna ISO 15713:2006","categories":["environment"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Hydrogen fluoride content","parameters_en":[{"name":"Range","range":"(0,002 – 10,00) mg w próbce"}],"search_en":"General environment – waste gas samples Hydrogen fluoride content Potentiometric method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range ISO 15713:2006","technique_en":"Potentiometric method","test_object_en":"General environment – waste gas samples","parameters_zh":[{"name":"范围","range":"(0,002 – 10,00) mg w próbce"}],"search_zh":"氟化氢含量 电位法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 ISO 15713:2006","technique_zh":"电位法","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_zh":"氟化氢含量"},{"_id":"6a7d7570441eff5f15648778","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Urządzenia odpylające gazy odlotowe","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"(0,001 – 100) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna","reference":"PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PN-87/M-34129, metoda A","norm_bases":["PN-Z-04030-7:1994","PN-EN 13284-1:2018-02","PN-87/M-34129, metoda A"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia odpylające gazy odlotowe Stężenie pyłu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PN-87/M-34129, metoda A Urzadzenia odpylajace gazy odlotowe Stezenie pylu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PN-87/M-34129, metoda A","categories":["other"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"(0,001 – 100) g/m3"}],"search_en":"Waste gas dedusting equipment Dust concentration Gravimetric method ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński Range PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PN-87/M-34129, metoda A","technique_en":"Gravimetric method","test_object_en":"Waste gas dedusting equipment","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,001 – 100) g/m3"}],"search_zh":"废气除尘设备 粉尘浓度 重量法 ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński 范围 PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PN-87/M-34129, metoda A","technique_zh":"重量法","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","test_object_zh":"废气除尘设备"},{"_id":"6a7d7570441eff5f15648779","lab_id":"69ad52a3de79e566650fb50c","country":"PL","accr_number":"AB 1004","accr_body":"PCA","test_object":"Urządzenia odpylające gazy odlotowe","methodology":"Skuteczność odpylania (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczność odpylania (z obliczeń)","reference":"PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PN-87/M-34129, metoda A","norm_bases":["PN-Z-04030-7:1994","PN-EN 13284-1:2018-02","PN-87/M-34129, metoda A"],"lab_section":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia odpylające gazy odlotowe Skuteczność odpylania (z obliczeń) PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PN-87/M-34129, metoda A Urzadzenia odpylajace gazy odlotowe Skutecznosc odpylania (z obliczen) PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PN-87/M-34129, metoda A","categories":["other"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","methodology_en":"Dust removal efficiency (calculated)","search_en":"Waste gas dedusting equipment Dust removal efficiency (calculated) ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PN-87/M-34129, metoda A","test_object_en":"Waste gas dedusting equipment","lab_section_zh":"”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński","search_zh":"废气除尘设备 除尘效率（由计算得出） ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PN-87/M-34129, metoda A","test_object_zh":"废气除尘设备","methodology_zh":"除尘效率（由计算得出）"}],"has_pdf":true}