{"lab":{"_id":"69ad52a3de79e566650fb117","accr_number":"AB 099","country":"PL","accr_body":"PCA","address":"ul. Stoczniowa 2, 82-300 Elbląg","categories":["materials"],"city":"Elbląg","imported_at":"2026-03-08T10:42:43.265Z","methods_count":27,"name":"„METROTEST” Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_099.pdf"],"scope_summary":"","search_text":"„metrotest” sp. z o.o. ul. stoczniowa 2, 82-300 elbląg other metrology materials","status":"active","updated_at":"2026-03-08T14:50:10.771Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T07:37:38.515Z","parse_date":"2026-08-13T07:37:38.515Z","parse_source":"agent-claude-code","email_confidence":"high","email_mx":true,"email_source":"https://www.metrotest.com.pl/kontakt","fields_of_testing":[{"codes":"C/8","pl":"Badania chemiczne wyrobów i materiałów konstrukcyjnych","en":"Chemical tests of construction products and materials"},{"codes":"J/8","pl":"Badania mechaniczne i metalograficzne wyrobów i materiałów konstrukcyjnych","en":"Mechanical tests, metallographic test of construction products and materials"}],"issue":{"no":"24","date":"06.08.2026"},"map_coord":[54.163435,19.391904],"map_geo":"nominatim-street","lab_locations":[{"name":"Laboratorium Badawcze (MT2)","address":"ul. Stoczniowa 2; 82-300 Elbląg","city":"Elbląg","postal":"82-300"},{"name":"Laboratorium Długości i Kąta (MT3)","address":"ul. Stoczniowa 2; 82-300 Elbląg","city":"Elbląg","postal":"82-300"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/21cc9f0ec6fe8e0be236f6b0c2421841/AB%20099.pdf","has_en":true,"category_counts":{"other":23,"materials":4},"category_scores":{"other":19.59,"materials":0.59},"has_zh":true,"lab_locations_zh":[{"name":"检测实验室（MT2）","address":"ul. Stoczniowa 2; 82-300 Elbląg","city":"Elbląg","postal":"82-300"},{"name":"Laboratorium Długości i Kąta (MT3)","address":"ul. Stoczniowa 2; 82-300 Elbląg","city":"Elbląg","postal":"82-300"}]},"methods":[{"_id":"6a7d7442ec6a53014a48771b","lab_id":"69ad52a3de79e566650fb117","country":"PL","accr_number":"AB 099","accr_body":"PCA","test_object":"Wyroby hutnicze i odlewnicze","methodology":"Własności mechaniczne","parameters":[{"name":"wyraźna granica plastyczności Re"},{"name":"umowna granica plastyczności Rp"},{"name":"wytrzymałość na rozciąganie Rm"},{"name":"wydłużenie A, Agt"},{"name":"przewężenie Z Zakres siły F","range":"do 1000 kN"},{"name":"Próba rozciągania w temperaturze pokojowej"}],"technique":null,"techniques":[],"computed":[],"activity":"Własności mechaniczne\nZakres:\nwyraźna granica plastyczności Re\numowna granica plastyczności Rp\nwytrzymałość na rozciąganie Rm\nwydłużenie A, Agt\nprzewężenie Z Zakres siły F do 1000 kN\nPróba rozciągania w temperaturze pokojowej","reference":"PN-EN ISO 6892-1:2020-05 Metoda B | ASTM E8/E8M-21","norm_bases":["PN-EN ISO 6892-1:2020-05 Metoda B","ASTM E8/E8M-21"],"lab_section":"Laboratorium Badawcze (MT2)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby hutnicze i odlewnicze Własności mechaniczne\nZakres:\nwyraźna granica plastyczności Re\numowna granica plastyczności Rp\nwytrzymałość na rozciąganie Rm\nwydłużenie A, Agt\nprzewężenie Z Zakres siły F do 1000 kN\nPróba rozciągania w temperaturze pokojowej PN-EN ISO 6892-1:2020-05 Metoda B | ASTM E8/E8M-21 Wyroby hutnicze i odlewnicze Wlasnosci mechaniczne\nZakres:\nwyrazna granica plastycznosci Re\numowna granica plastycznosci Rp\nwytrzymalosc na rozciaganie Rm\nwydluzenie A, Agt\nprzewezenie Z Zakres sily F do 1000 kN\nProba rozciagania w temperaturze pokojowej PN-EN ISO 6892-1:2020-05 Metoda B | ASTM E8/E8M-21","categories":["other"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory (MT2)","methodology_en":"Mechanical properties","parameters_en":[{"name":"distinct yield strength Re"},{"name":"proof strength, plastic extension Rp"},{"name":"tensile strength Rm"},{"name":"elongation A, Agt"},{"name":"reduction of area Z Force range F","range":"do 1000 kN"},{"name":"Tensile test at room temperature"}],"search_en":"Steel mill and foundry products Mechanical properties Testing Laboratory (MT2) distinct yield strength Re proof strength, plastic extension Rp tensile strength Rm elongation A, Agt reduction of area Z Force range F Tensile test at room temperature PN-EN ISO 6892-1:2020-05 Metoda B | ASTM E8/E8M-21","test_object_en":"Steel mill and foundry products","parameters_zh":[{"name":"明显屈服强度 Re"},{"name":"规定塑性延伸强度 Rp"},{"name":"抗拉强度 Rm"},{"name":"伸长率 A、Agt"},{"name":"przewężenie Z Zakres siły F","range":"do 1000 kN"},{"name":"室温拉伸试验"}],"search_zh":"冶金制品与铸造制品 力学性能 检测实验室（MT2） 明显屈服强度 Re 规定塑性延伸强度 Rp 抗拉强度 Rm 伸长率 A、Agt 室温拉伸试验 PN-EN ISO 6892-1:2020-05 Metoda B | ASTM E8/E8M-21","lab_section_zh":"检测实验室（MT2）","methodology_zh":"力学性能","test_object_zh":"冶金制品与铸造制品"},{"_id":"6a7d7442ec6a53014a48771c","lab_id":"69ad52a3de79e566650fb117","country":"PL","accr_number":"AB 099","accr_body":"PCA","test_object":"Wyroby hutnicze i odlewnicze","methodology":"Własności mechaniczne","parameters":[{"name":"granica plastyczności Re/Rp"},{"name":"wytrzymałość na rozciąganie Rm"},{"name":"wydłużenie A"},{"name":"przewężenie Z Zakres siły F","range":"do 200 kN"},{"name":"Próba rozciągania w temperaturze","range":"do 600 0C"}],"technique":null,"techniques":[],"computed":[],"activity":"Własności mechaniczne\nZakres:\ngranica plastyczności Re/Rp\nwytrzymałość na rozciąganie Rm\nwydłużenie A\nprzewężenie Z Zakres siły F do 200 kN\nPróba rozciągania w temperaturze do 600 0C","reference":"PN-EN ISO 6892-2:2018-08, Metoda B | ASTM E21-20","norm_bases":["PN-EN ISO 6892-2:2018-08, Metoda B","ASTM E21-20"],"lab_section":"Laboratorium Badawcze (MT2)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby hutnicze i odlewnicze Własności mechaniczne\nZakres:\ngranica plastyczności Re/Rp\nwytrzymałość na rozciąganie Rm\nwydłużenie A\nprzewężenie Z Zakres siły F do 200 kN\nPróba rozciągania w temperaturze do 600 0C PN-EN ISO 6892-2:2018-08, Metoda B | ASTM E21-20 Wyroby hutnicze i odlewnicze Wlasnosci mechaniczne\nZakres:\ngranica plastycznosci Re/Rp\nwytrzymalosc na rozciaganie Rm\nwydluzenie A\nprzewezenie Z Zakres sily F do 200 kN\nProba rozciagania w temperaturze do 600 0C PN-EN ISO 6892-2:2018-08, Metoda B | ASTM E21-20","categories":["other"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory (MT2)","methodology_en":"Mechanical properties","parameters_en":[{"name":"yield strength Re/Rp"},{"name":"tensile strength Rm"},{"name":"elongation A"},{"name":"reduction of area Z Force range F","range":"do 200 kN"},{"name":"Tensile test at temperature","range":"do 600 0C"}],"search_en":"Steel mill and foundry products Mechanical properties Testing Laboratory (MT2) yield strength Re/Rp tensile strength Rm elongation A reduction of area Z Force range F Tensile test at temperature PN-EN ISO 6892-2:2018-08, Metoda B | ASTM E21-20","test_object_en":"Steel mill and foundry products","parameters_zh":[{"name":"granica plastyczności Re/Rp"},{"name":"抗拉强度 Rm"},{"name":"伸长率 A"},{"name":"przewężenie Z Zakres siły F","range":"do 200 kN"},{"name":"Próba rozciągania w temperaturze","range":"do 600 0C"}],"search_zh":"冶金制品与铸造制品 力学性能 检测实验室（MT2） 抗拉强度 Rm 伸长率 A PN-EN ISO 6892-2:2018-08, Metoda B | ASTM E21-20","lab_section_zh":"检测实验室（MT2）","methodology_zh":"力学性能","test_object_zh":"冶金制品与铸造制品"},{"_id":"6a7d7442ec6a53014a48771d","lab_id":"69ad52a3de79e566650fb117","country":"PL","accr_number":"AB 099","accr_body":"PCA","test_object":"Wyroby hutnicze i odlewnicze","methodology":"Twardość HBW","parameters":[{"name":"Zakres","range":"średnica kulki 2,5 mm, 5 mm,"},{"name":"10 mm Twardość Brinella"}],"technique":null,"techniques":[],"computed":[],"activity":"Twardość HBW\nZakres:\nZakres średnica kulki 2,5 mm, 5 mm,\n10 mm Twardość Brinella","reference":"PN EN ISO 6506-1: 2014-12 | ASTM E10-17","norm_bases":["PN EN ISO 6506-1: 2014-12","ASTM E10-17"],"lab_section":"Laboratorium Badawcze (MT2)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby hutnicze i odlewnicze Twardość HBW\nZakres:\nZakres średnica kulki 2,5 mm, 5 mm,\n10 mm Twardość Brinella PN EN ISO 6506-1: 2014-12 | ASTM E10-17 Wyroby hutnicze i odlewnicze Twardosc HBW\nZakres:\nZakres srednica kulki 2,5 mm, 5 mm,\n10 mm Twardosc Brinella PN EN ISO 6506-1: 2014-12 | ASTM E10-17","categories":["other"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory (MT2)","methodology_en":"HBW hardness","parameters_en":[{"name":"Range","range":"średnica kulki 2,5 mm, 5 mm,"},{"name":"10 mm Brinell hardness"}],"search_en":"Steel mill and foundry products HBW hardness Testing Laboratory (MT2) Range 10 mm Brinell hardness PN EN ISO 6506-1: 2014-12 | ASTM E10-17","test_object_en":"Steel mill and foundry products","parameters_zh":[{"name":"范围","range":"średnica kulki 2,5 mm, 5 mm,"},{"name":"10 mm Twardość Brinella"}],"search_zh":"冶金制品与铸造制品 布氏硬度 HBW 检测实验室（MT2） 范围 PN EN ISO 6506-1: 2014-12 | ASTM E10-17","lab_section_zh":"检测实验室（MT2）","methodology_zh":"布氏硬度 HBW","test_object_zh":"冶金制品与铸造制品"},{"_id":"6a7d7442ec6a53014a48771e","lab_id":"69ad52a3de79e566650fb117","country":"PL","accr_number":"AB 099","accr_body":"PCA","test_object":"Wyroby hutnicze i odlewnicze","methodology":"Twardość HV","parameters":[{"name":"Zakres","range":"HV0,5; HV1HV5; HV10;"},{"name":"HV30;"}],"technique":"Metoda Vickersa","techniques":["Metoda Vickersa"],"computed":[],"activity":"Twardość HV\nZakres:\nZakres HV0,5; HV1HV5; HV10;\nHV30;\nMetoda Vickersa","reference":"PN-EN ISO 6507-1:2024-04","norm_bases":["PN-EN ISO 6507-1:2024-04"],"lab_section":"Laboratorium Badawcze (MT2)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby hutnicze i odlewnicze Twardość HV\nZakres:\nZakres HV0,5; HV1HV5; HV10;\nHV30;\nMetoda Vickersa PN-EN ISO 6507-1:2024-04 Wyroby hutnicze i odlewnicze Twardosc HV\nZakres:\nZakres HV0,5; HV1HV5; HV10;\nHV30;\nMetoda Vickersa PN-EN ISO 6507-1:2024-04","categories":["other"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory (MT2)","methodology_en":"HV hardness","parameters_en":[{"name":"Range","range":"HV0,5; HV1HV5; HV10;"},{"name":"HV30;"}],"search_en":"Steel mill and foundry products HV hardness Vickers method Testing Laboratory (MT2) Range HV30; PN-EN ISO 6507-1:2024-04","technique_en":"Vickers method","test_object_en":"Steel mill and foundry products","parameters_zh":[{"name":"范围","range":"HV0,5; HV1HV5; HV10;"},{"name":"HV30;"}],"search_zh":"冶金制品与铸造制品 维氏硬度 HV 维氏法 检测实验室（MT2） 范围 PN-EN ISO 6507-1:2024-04","methodology_zh":"维氏硬度 HV","technique_zh":"维氏法","lab_section_zh":"检测实验室（MT2）","test_object_zh":"冶金制品与铸造制品"},{"_id":"6a7d7442ec6a53014a48771f","lab_id":"69ad52a3de79e566650fb117","country":"PL","accr_number":"AB 099","accr_body":"PCA","test_object":"Wyroby hutnicze i odlewnicze","methodology":"Głębokość odwęglenia, Zakres HV0,5; HV1","parameters":[],"technique":"Metoda Vickersa","techniques":["Metoda Vickersa"],"computed":[],"activity":"Głębokość odwęglenia, Zakres HV0,5; HV1\nMetoda Vickersa","reference":"PN-EN ISO 3887:2024-04","norm_bases":["PN-EN ISO 3887:2024-04"],"lab_section":"Laboratorium Badawcze (MT2)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby hutnicze i odlewnicze Głębokość odwęglenia, Zakres HV0,5; HV1\nMetoda Vickersa PN-EN ISO 3887:2024-04 Wyroby hutnicze i odlewnicze Glebokosc odweglenia, Zakres HV0,5; HV1\nMetoda Vickersa PN-EN ISO 3887:2024-04","categories":["other"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory (MT2)","methodology_en":"Decarburization depth, Range HV0,5; HV1","search_en":"Steel mill and foundry products Decarburization depth, Range HV0,5; HV1 Vickers method Testing Laboratory (MT2) PN-EN ISO 3887:2024-04","technique_en":"Vickers method","test_object_en":"Steel mill and foundry products","search_zh":"冶金制品与铸造制品 维氏法 检测实验室（MT2） PN-EN ISO 3887:2024-04","technique_zh":"维氏法","lab_section_zh":"检测实验室（MT2）","test_object_zh":"冶金制品与铸造制品"},{"_id":"6a7d7442ec6a53014a487720","lab_id":"69ad52a3de79e566650fb117","country":"PL","accr_number":"AB 099","accr_body":"PCA","test_object":"Wyroby hutnicze i odlewnicze","methodology":"Głębokość warstwy utwardzonej, Zakres HV0,5; HV1","parameters":[],"technique":"Metoda Vickersa","techniques":["Metoda Vickersa"],"computed":[],"activity":"Głębokość warstwy utwardzonej, Zakres HV0,5; HV1\nMetoda Vickersa","reference":"PN-EN ISO 18203:2022-09","norm_bases":["PN-EN ISO 18203:2022-09"],"lab_section":"Laboratorium Badawcze (MT2)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby hutnicze i odlewnicze Głębokość warstwy utwardzonej, Zakres HV0,5; HV1\nMetoda Vickersa PN-EN ISO 18203:2022-09 Wyroby hutnicze i odlewnicze Glebokosc warstwy utwardzonej, Zakres HV0,5; HV1\nMetoda Vickersa PN-EN ISO 18203:2022-09","categories":["other"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory (MT2)","methodology_en":"Depth of the hardened layer, Range HV0,5; HV1","search_en":"Steel mill and foundry products Depth of the hardened layer, Range HV0,5; HV1 Vickers method Testing Laboratory (MT2) PN-EN ISO 18203:2022-09","technique_en":"Vickers method","test_object_en":"Steel mill and foundry products","search_zh":"冶金制品与铸造制品 维氏法 检测实验室（MT2） PN-EN ISO 18203:2022-09","technique_zh":"维氏法","lab_section_zh":"检测实验室（MT2）","test_object_zh":"冶金制品与铸造制品"},{"_id":"6a7d7442ec6a53014a487721","lab_id":"69ad52a3de79e566650fb117","country":"PL","accr_number":"AB 099","accr_body":"PCA","test_object":"Wyroby hutnicze i odlewnicze","methodology":"Głębokość odwęglenia, Mikroskopia optyczna","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Głębokość odwęglenia, Mikroskopia optyczna","reference":"PN-EN ISO 3887:2024-04","norm_bases":["PN-EN ISO 3887:2024-04"],"lab_section":"Laboratorium Badawcze (MT2)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby hutnicze i odlewnicze Głębokość odwęglenia, Mikroskopia optyczna PN-EN ISO 3887:2024-04 Wyroby hutnicze i odlewnicze Glebokosc odweglenia, Mikroskopia optyczna PN-EN ISO 3887:2024-04","categories":["other"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory (MT2)","methodology_en":"Decarburization depth, Optical microscopy","search_en":"Steel mill and foundry products Decarburization depth, Optical microscopy Testing Laboratory (MT2) PN-EN ISO 3887:2024-04","test_object_en":"Steel mill and foundry products","lab_section_zh":"检测实验室（MT2）","search_zh":"冶金制品与铸造制品 检测实验室（MT2） PN-EN ISO 3887:2024-04","test_object_zh":"冶金制品与铸造制品"},{"_id":"6a7d7442ec6a53014a487722","lab_id":"69ad52a3de79e566650fb117","country":"PL","accr_number":"AB 099","accr_body":"PCA","test_object":"Wyroby hutnicze i odlewnicze","methodology":"Wielkość ziarna, Mikroskopia optyczna","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wielkość ziarna, Mikroskopia optyczna","reference":"ASTM E112-13(2021) | PN-EN ISO 643:2025-02","norm_bases":["ASTM E112-13(2021)","PN-EN ISO 643:2025-02"],"lab_section":"Laboratorium Badawcze (MT2)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby hutnicze i odlewnicze Wielkość ziarna, Mikroskopia optyczna ASTM E112-13(2021) | PN-EN ISO 643:2025-02 Wyroby hutnicze i odlewnicze Wielkosc ziarna, Mikroskopia optyczna ASTM E112-13(2021) | PN-EN ISO 643:2025-02","categories":["other"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory (MT2)","methodology_en":"Grain size, Optical microscopy","search_en":"Steel mill and foundry products Grain size, Optical microscopy Testing Laboratory (MT2) ASTM E112-13(2021) | PN-EN ISO 643:2025-02","test_object_en":"Steel mill and foundry products","lab_section_zh":"检测实验室（MT2）","search_zh":"冶金制品与铸造制品 晶粒度，光学显微镜 检测实验室（MT2） ASTM E112-13(2021) | PN-EN ISO 643:2025-02","test_object_zh":"冶金制品与铸造制品","methodology_zh":"晶粒度，光学显微镜"},{"_id":"6a7d7442ec6a53014a487723","lab_id":"69ad52a3de79e566650fb117","country":"PL","accr_number":"AB 099","accr_body":"PCA","test_object":"Wyroby hutnicze i odlewnicze","methodology":"Głębokość warstwy utwardzonej, Grubość warstwy białej, Mikroskopia optyczna","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Głębokość warstwy utwardzonej, Grubość warstwy białej, Mikroskopia optyczna","reference":"PN-82/H-04550 | PN-EN ISO 18203:2022-09","norm_bases":["PN-82/H-04550","PN-EN ISO 18203:2022-09"],"lab_section":"Laboratorium Badawcze (MT2)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby hutnicze i odlewnicze Głębokość warstwy utwardzonej, Grubość warstwy białej, Mikroskopia optyczna PN-82/H-04550 | PN-EN ISO 18203:2022-09 Wyroby hutnicze i odlewnicze Glebokosc warstwy utwardzonej, Grubosc warstwy bialej, Mikroskopia optyczna PN-82/H-04550 | PN-EN ISO 18203:2022-09","categories":["other"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory (MT2)","methodology_en":"Depth of the hardened layer, Thickness of the white layer, Optical microscopy","search_en":"Steel mill and foundry products Depth of the hardened layer, Thickness of the white layer, Optical microscopy Testing Laboratory (MT2) PN-82/H-04550 | PN-EN ISO 18203:2022-09","test_object_en":"Steel mill and foundry products","lab_section_zh":"检测实验室（MT2）","search_zh":"冶金制品与铸造制品 检测实验室（MT2） PN-82/H-04550 | PN-EN ISO 18203:2022-09","test_object_zh":"冶金制品与铸造制品"},{"_id":"6a7d7442ec6a53014a487724","lab_id":"69ad52a3de79e566650fb117","country":"PL","accr_number":"AB 099","accr_body":"PCA","test_object":"Wyroby hutnicze i odlewnicze","methodology":"Twardość HR","parameters":[{"name":"Zakres","range":"skala C i B"}],"technique":"Metoda Rockwella","techniques":["Metoda Rockwella"],"computed":[],"activity":"Twardość HR\nZakres skala C i B\nMetoda Rockwella","reference":"PN-EN ISO 6508-1:2024-06","norm_bases":["PN-EN ISO 6508-1:2024-06"],"lab_section":"Laboratorium Badawcze (MT2)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby hutnicze i odlewnicze Twardość HR\nZakres skala C i B\nMetoda Rockwella PN-EN ISO 6508-1:2024-06 Wyroby hutnicze i odlewnicze Twardosc HR\nZakres skala C i B\nMetoda Rockwella PN-EN ISO 6508-1:2024-06","categories":["other"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory (MT2)","methodology_en":"HR hardness","parameters_en":[{"name":"Range","range":"skala C i B"}],"search_en":"Steel mill and foundry products HR hardness Rockwell method Testing Laboratory (MT2) Range PN-EN ISO 6508-1:2024-06","technique_en":"Rockwell method","test_object_en":"Steel mill and foundry products","parameters_zh":[{"name":"范围","range":"skala C i B"}],"search_zh":"冶金制品与铸造制品 洛氏硬度 HR 洛氏法 检测实验室（MT2） 范围 PN-EN ISO 6508-1:2024-06","lab_section_zh":"检测实验室（MT2）","technique_zh":"洛氏法","test_object_zh":"冶金制品与铸造制品","methodology_zh":"洛氏硬度 HR"},{"_id":"6a7d7442ec6a53014a487725","lab_id":"69ad52a3de79e566650fb117","country":"PL","accr_number":"AB 099","accr_body":"PCA","test_object":"Wyroby hutnicze i odlewnicze","methodology":"Praca łamania, Zakres KV2; KU2, KV8, Początkowa energia młota 300 J, Zakres temperatur od -70 0C do +500°C i w temp. ciekłego azotu, Próba udarności sposobem, Charpy’ego","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Praca łamania, Zakres KV2; KU2, KV8, Początkowa energia młota 300 J, Zakres temperatur od -70 0C do +500°C i w temp. ciekłego azotu, Próba udarności sposobem, Charpy’ego","reference":"PN-EN ISO 148-1:2017-02 | ASTM E23-23a","norm_bases":["PN-EN ISO 148-1:2017-02","ASTM E23-23a"],"lab_section":"Laboratorium Badawcze (MT2)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby hutnicze i odlewnicze Praca łamania, Zakres KV2; KU2, KV8, Początkowa energia młota 300 J, Zakres temperatur od -70 0C do +500°C i w temp. ciekłego azotu, Próba udarności sposobem, Charpy’ego PN-EN ISO 148-1:2017-02 | ASTM E23-23a Wyroby hutnicze i odlewnicze Praca lamania, Zakres KV2; KU2, KV8, Poczatkowa energia mlota 300 J, Zakres temperatur od -70 0C do +500°C i w temp. cieklego azotu, Proba udarnosci sposobem, Charpy’ego PN-EN ISO 148-1:2017-02 | ASTM E23-23a","categories":["other"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory (MT2)","methodology_en":"Absorbed impact energy, Range KV2; KU2, KV8, Initial hammer energy 300 J, Temperature range from -70 0C to +500°C and at liquid nitrogen temperature, Impact test by the, Charpy method","search_en":"Steel mill and foundry products Absorbed impact energy, Range KV2; KU2, KV8, Initial hammer energy 300 J, Temperature range from -70 0C to +500°C and at liquid nitrogen temperature, Impact test by the, Charpy method Testing Laboratory (MT2) PN-EN ISO 148-1:2017-02 | ASTM E23-23a","test_object_en":"Steel mill and foundry products","lab_section_zh":"检测实验室（MT2）","search_zh":"冶金制品与铸造制品 检测实验室（MT2） PN-EN ISO 148-1:2017-02 | ASTM E23-23a","test_object_zh":"冶金制品与铸造制品"},{"_id":"6a7d7442ec6a53014a487726","lab_id":"69ad52a3de79e566650fb117","country":"PL","accr_number":"AB 099","accr_body":"PCA","test_object":"Wyroby hutnicze i odlewnicze","methodology":"Przełom próbki udarnościowej","parameters":[{"name":"temperatura przejścia Tt"},{"name":"procentowy udział przełomu SFA"},{"name":"rozszerzenie boczne próbek LE Próba udarności sposobem Charpy’ego"}],"technique":null,"techniques":[],"computed":[],"activity":"Przełom próbki udarnościowej\nZakres:\ntemperatura przejścia Tt\nprocentowy udział przełomu SFA\nrozszerzenie boczne próbek LE Próba udarności sposobem Charpy’ego","reference":"PN-EN ISO 148-1:2017-02 | ASTM E23-23a","norm_bases":["PN-EN ISO 148-1:2017-02","ASTM E23-23a"],"lab_section":"Laboratorium Badawcze (MT2)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby hutnicze i odlewnicze Przełom próbki udarnościowej\nZakres:\ntemperatura przejścia Tt\nprocentowy udział przełomu SFA\nrozszerzenie boczne próbek LE Próba udarności sposobem Charpy’ego PN-EN ISO 148-1:2017-02 | ASTM E23-23a Wyroby hutnicze i odlewnicze Przelom probki udarnosciowej\nZakres:\ntemperatura przejscia Tt\nprocentowy udzial przelomu SFA\nrozszerzenie boczne probek LE Proba udarnosci sposobem Charpy’ego PN-EN ISO 148-1:2017-02 | ASTM E23-23a","categories":["other"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory (MT2)","methodology_en":"Fracture surface of the impact test specimen","parameters_en":[{"name":"transition temperature Tt"},{"name":"percentage of shear fracture area SFA"},{"name":"lateral expansion of specimens LE Charpy impact test"}],"search_en":"Steel mill and foundry products Fracture surface of the impact test specimen Testing Laboratory (MT2) transition temperature Tt percentage of shear fracture area SFA lateral expansion of specimens LE Charpy impact test PN-EN ISO 148-1:2017-02 | ASTM E23-23a","test_object_en":"Steel mill and foundry products","lab_section_zh":"检测实验室（MT2）","search_zh":"冶金制品与铸造制品 检测实验室（MT2） PN-EN ISO 148-1:2017-02 | ASTM E23-23a","test_object_zh":"冶金制品与铸造制品"},{"_id":"6a7d7442ec6a53014a487727","lab_id":"69ad52a3de79e566650fb117","country":"PL","accr_number":"AB 099","accr_body":"PCA","test_object":"Wyroby hutnicze i odlewnicze","methodology":"Podatność na odkształcenia plastyczne, Technologiczna próba zginania","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Podatność na odkształcenia plastyczne, Technologiczna próba zginania","reference":"PN-EN ISO 7438:2021-04","norm_bases":["PN-EN ISO 7438:2021-04"],"lab_section":"Laboratorium Badawcze (MT2)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby hutnicze i odlewnicze Podatność na odkształcenia plastyczne, Technologiczna próba zginania PN-EN ISO 7438:2021-04 Wyroby hutnicze i odlewnicze Podatnosc na odksztalcenia plastyczne, Technologiczna proba zginania PN-EN ISO 7438:2021-04","categories":["other"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory (MT2)","methodology_en":"Susceptibility to plastic deformation, Technological bend test","search_en":"Steel mill and foundry products Susceptibility to plastic deformation, Technological bend test Testing Laboratory (MT2) PN-EN ISO 7438:2021-04","test_object_en":"Steel mill and foundry products","lab_section_zh":"检测实验室（MT2）","search_zh":"冶金制品与铸造制品 检测实验室（MT2） PN-EN ISO 7438:2021-04","test_object_zh":"冶金制品与铸造制品"},{"_id":"6a7d7442ec6a53014a487728","lab_id":"69ad52a3de79e566650fb117","country":"PL","accr_number":"AB 099","accr_body":"PCA","test_object":"Odlewy","methodology":"Mikrostruktura, Mikroskopia optyczna","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Mikrostruktura, Mikroskopia optyczna","reference":"PN-EN ISO 945-1:2019-09 | PN-75/H-04661","norm_bases":["PN-EN ISO 945-1:2019-09","PN-75/H-04661"],"lab_section":"Laboratorium Badawcze (MT2)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odlewy Mikrostruktura, Mikroskopia optyczna PN-EN ISO 945-1:2019-09 | PN-75/H-04661 Odlewy Mikrostruktura, Mikroskopia optyczna PN-EN ISO 945-1:2019-09 | PN-75/H-04661","categories":["other"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory (MT2)","methodology_en":"Microstructure, Optical microscopy","search_en":"Castings Microstructure, Optical microscopy Testing Laboratory (MT2) PN-EN ISO 945-1:2019-09 | PN-75/H-04661","test_object_en":"Castings","lab_section_zh":"检测实验室（MT2）","search_zh":"铸件 显微组织，光学显微镜 检测实验室（MT2） PN-EN ISO 945-1:2019-09 | PN-75/H-04661","test_object_zh":"铸件","methodology_zh":"显微组织，光学显微镜"},{"_id":"6a7d7442ec6a53014a487729","lab_id":"69ad52a3de79e566650fb117","country":"PL","accr_number":"AB 099","accr_body":"PCA","test_object":"Złącza spawane","methodology":"Własności mechaniczne","parameters":[{"name":"wytrzymałość na rozciąganie Rm"},{"name":"wydłużenie A Zakres siły F","range":"do 1000 kN"},{"name":"Próba rozciągania w temperaturze pokojowej"}],"technique":null,"techniques":[],"computed":[],"activity":"Własności mechaniczne\nZakres:\nwytrzymałość na rozciąganie Rm\nwydłużenie A Zakres siły F do 1000 kN\nPróba rozciągania w temperaturze pokojowej","reference":"PN EN ISO 4136:2022-12 | PN-EN ISO 5178:2019-04 | PN-EN ISO 6892-1:2020-05 Metoda B","norm_bases":["PN EN ISO 4136:2022-12","PN-EN ISO 5178:2019-04","PN-EN ISO 6892-1:2020-05 Metoda B"],"lab_section":"Laboratorium Badawcze (MT2)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Złącza spawane Własności mechaniczne\nZakres:\nwytrzymałość na rozciąganie Rm\nwydłużenie A Zakres siły F do 1000 kN\nPróba rozciągania w temperaturze pokojowej PN EN ISO 4136:2022-12 | PN-EN ISO 5178:2019-04 | PN-EN ISO 6892-1:2020-05 Metoda B Zlacza spawane Wlasnosci mechaniczne\nZakres:\nwytrzymalosc na rozciaganie Rm\nwydluzenie A Zakres sily F do 1000 kN\nProba rozciagania w temperaturze pokojowej PN EN ISO 4136:2022-12 | PN-EN ISO 5178:2019-04 | PN-EN ISO 6892-1:2020-05 Metoda B","categories":["other"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory (MT2)","methodology_en":"Mechanical properties","parameters_en":[{"name":"tensile strength Rm"},{"name":"elongation A Force range F","range":"do 1000 kN"},{"name":"Tensile test at room temperature"}],"search_en":"Welded joints Mechanical properties Testing Laboratory (MT2) tensile strength Rm elongation A Force range F Tensile test at room temperature PN EN ISO 4136:2022-12 | PN-EN ISO 5178:2019-04 | PN-EN ISO 6892-1:2020-05 Metoda B","test_object_en":"Welded joints","search_zh":"焊接接头 力学性能 检测实验室（MT2） 抗拉强度 Rm 室温拉伸试验 PN EN ISO 4136:2022-12 | PN-EN ISO 5178:2019-04 | PN-EN ISO 6892-1:2020-05 Metoda B","test_object_zh":"焊接接头","parameters_zh":[{"name":"抗拉强度 Rm"},{"name":"wydłużenie A Zakres siły F","range":"do 1000 kN"},{"name":"室温拉伸试验"}],"lab_section_zh":"检测实验室（MT2）","methodology_zh":"力学性能"},{"_id":"6a7d7442ec6a53014a48772a","lab_id":"69ad52a3de79e566650fb117","country":"PL","accr_number":"AB 099","accr_body":"PCA","test_object":"Złącza spawane","methodology":"Praca łamania, Zakres KV2; KU2, KV8, Początkowa energia młota 300 J, Zakres temperatur od -70 0C do +500°C i w temp. ciekłego azotu, Próba udarności sposobem, Charpy’ego","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Praca łamania, Zakres KV2; KU2, KV8, Początkowa energia młota 300 J, Zakres temperatur od -70 0C do +500°C i w temp. ciekłego azotu, Próba udarności sposobem, Charpy’ego","reference":"PN-EN ISO 148-1:2017-02 | PN-EN ISO 9016:2022-09 | ASTM E23-23a","norm_bases":["PN-EN ISO 148-1:2017-02","PN-EN ISO 9016:2022-09","ASTM E23-23a"],"lab_section":"Laboratorium Badawcze (MT2)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Złącza spawane Praca łamania, Zakres KV2; KU2, KV8, Początkowa energia młota 300 J, Zakres temperatur od -70 0C do +500°C i w temp. ciekłego azotu, Próba udarności sposobem, Charpy’ego PN-EN ISO 148-1:2017-02 | PN-EN ISO 9016:2022-09 | ASTM E23-23a Zlacza spawane Praca lamania, Zakres KV2; KU2, KV8, Poczatkowa energia mlota 300 J, Zakres temperatur od -70 0C do +500°C i w temp. cieklego azotu, Proba udarnosci sposobem, Charpy’ego PN-EN ISO 148-1:2017-02 | PN-EN ISO 9016:2022-09 | ASTM E23-23a","categories":["other"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory (MT2)","methodology_en":"Absorbed impact energy, Range KV2; KU2, KV8, Initial hammer energy 300 J, Temperature range from -70 0C to +500°C and at liquid nitrogen temperature, Impact test by the, Charpy method","search_en":"Welded joints Absorbed impact energy, Range KV2; KU2, KV8, Initial hammer energy 300 J, Temperature range from -70 0C to +500°C and at liquid nitrogen temperature, Impact test by the, Charpy method Testing Laboratory (MT2) PN-EN ISO 148-1:2017-02 | PN-EN ISO 9016:2022-09 | ASTM E23-23a","test_object_en":"Welded joints","search_zh":"焊接接头 检测实验室（MT2） PN-EN ISO 148-1:2017-02 | PN-EN ISO 9016:2022-09 | ASTM E23-23a","test_object_zh":"焊接接头","lab_section_zh":"检测实验室（MT2）"},{"_id":"6a7d7442ec6a53014a48772b","lab_id":"69ad52a3de79e566650fb117","country":"PL","accr_number":"AB 099","accr_body":"PCA","test_object":"Złącza spawane","methodology":"Podatność na odkształcenia plastyczne, Próba zginania spawanych złączy metali","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Podatność na odkształcenia plastyczne, Próba zginania spawanych złączy metali","reference":"PN-EN ISO 5173:2023-06","norm_bases":["PN-EN ISO 5173:2023-06"],"lab_section":"Laboratorium Badawcze (MT2)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Złącza spawane Podatność na odkształcenia plastyczne, Próba zginania spawanych złączy metali PN-EN ISO 5173:2023-06 Zlacza spawane Podatnosc na odksztalcenia plastyczne, Proba zginania spawanych zlaczy metali PN-EN ISO 5173:2023-06","categories":["materials"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory (MT2)","methodology_en":"Susceptibility to plastic deformation, Bend test of welded metal joints","search_en":"Welded joints Susceptibility to plastic deformation, Bend test of welded metal joints Testing Laboratory (MT2) PN-EN ISO 5173:2023-06","test_object_en":"Welded joints","search_zh":"焊接接头 检测实验室（MT2） PN-EN ISO 5173:2023-06","test_object_zh":"焊接接头","lab_section_zh":"检测实验室（MT2）"},{"_id":"6a7d7442ec6a53014a48772c","lab_id":"69ad52a3de79e566650fb117","country":"PL","accr_number":"AB 099","accr_body":"PCA","test_object":"Złącza spawane","methodology":"Twardość na przekroju, Zakres HV1, HV5, HV10","parameters":[],"technique":"Metoda Vickersa","techniques":["Metoda Vickersa"],"computed":[],"activity":"Twardość na przekroju, Zakres HV1, HV5, HV10\nMetoda Vickersa","reference":"PN-EN ISO 6507-1:2024-04 | PN-EN ISO 9015-1:2011 | PN-EN ISO 9015-2:2016-04","norm_bases":["PN-EN ISO 6507-1:2024-04","PN-EN ISO 9015-1:2011","PN-EN ISO 9015-2:2016-04"],"lab_section":"Laboratorium Badawcze (MT2)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Złącza spawane Twardość na przekroju, Zakres HV1, HV5, HV10\nMetoda Vickersa PN-EN ISO 6507-1:2024-04 | PN-EN ISO 9015-1:2011 | PN-EN ISO 9015-2:2016-04 Zlacza spawane Twardosc na przekroju, Zakres HV1, HV5, HV10\nMetoda Vickersa PN-EN ISO 6507-1:2024-04 | PN-EN ISO 9015-1:2011 | PN-EN ISO 9015-2:2016-04","categories":["other"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory (MT2)","methodology_en":"Hardness across the cross-section, Range HV1, HV5, HV10","search_en":"Welded joints Hardness across the cross-section, Range HV1, HV5, HV10 Vickers method Testing Laboratory (MT2) PN-EN ISO 6507-1:2024-04 | PN-EN ISO 9015-1:2011 | PN-EN ISO 9015-2:2016-04","technique_en":"Vickers method","test_object_en":"Welded joints","search_zh":"焊接接头 维氏法 检测实验室（MT2） PN-EN ISO 6507-1:2024-04 | PN-EN ISO 9015-1:2011 | PN-EN ISO 9015-2:2016-04","test_object_zh":"焊接接头","technique_zh":"维氏法","lab_section_zh":"检测实验室（MT2）"},{"_id":"6a7d7442ec6a53014a48772d","lab_id":"69ad52a3de79e566650fb117","country":"PL","accr_number":"AB 099","accr_body":"PCA","test_object":"Złącza spawane","methodology":"Mikrostruktura, Mikroskopia optyczna","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Mikrostruktura, Mikroskopia optyczna","reference":"PN-EN ISO 17639:2022-07","norm_bases":["PN-EN ISO 17639:2022-07"],"lab_section":"Laboratorium Badawcze (MT2)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Złącza spawane Mikrostruktura, Mikroskopia optyczna PN-EN ISO 17639:2022-07 Zlacza spawane Mikrostruktura, Mikroskopia optyczna PN-EN ISO 17639:2022-07","categories":["other"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory (MT2)","methodology_en":"Microstructure, Optical microscopy","search_en":"Welded joints Microstructure, Optical microscopy Testing Laboratory (MT2) PN-EN ISO 17639:2022-07","test_object_en":"Welded joints","search_zh":"焊接接头 显微组织，光学显微镜 检测实验室（MT2） PN-EN ISO 17639:2022-07","test_object_zh":"焊接接头","lab_section_zh":"检测实验室（MT2）","methodology_zh":"显微组织，光学显微镜"},{"_id":"6a7d7442ec6a53014a48772e","lab_id":"69ad52a3de79e566650fb117","country":"PL","accr_number":"AB 099","accr_body":"PCA","test_object":"Złącza spawane","methodology":"Wady złączy spawanych, Badania makroskopowe","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wady złączy spawanych, Badania makroskopowe","reference":"PN-EN ISO 17639:2022-07","norm_bases":["PN-EN ISO 17639:2022-07"],"lab_section":"Laboratorium Badawcze (MT2)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Złącza spawane Wady złączy spawanych, Badania makroskopowe PN-EN ISO 17639:2022-07 Zlacza spawane Wady zlaczy spawanych, Badania makroskopowe PN-EN ISO 17639:2022-07","categories":["other"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory (MT2)","methodology_en":"Defects of welded joints, Macroscopic examinations","search_en":"Welded joints Defects of welded joints, Macroscopic examinations Testing Laboratory (MT2) PN-EN ISO 17639:2022-07","test_object_en":"Welded joints","search_zh":"焊接接头 检测实验室（MT2） PN-EN ISO 17639:2022-07","test_object_zh":"焊接接头","lab_section_zh":"检测实验室（MT2）"},{"_id":"6a7d7442ec6a53014a48772f","lab_id":"69ad52a3de79e566650fb117","country":"PL","accr_number":"AB 099","accr_body":"PCA","test_object":"Wyroby hutnicze i odlewnicze o dużych gabarytach","methodology":"Twardość","parameters":[],"technique":"Metoda UCI/ Pomiar twardości poprzez pomiar powierzchni odcisku metodą ultradźwiękową","techniques":["Metoda UCI/ Pomiar twardości poprzez pomiar powierzchni odcisku metodą ultradźwiękową"],"computed":[],"activity":"Twardość\nMetoda UCI/ Pomiar twardości poprzez pomiar powierzchni odcisku metodą ultradźwiękową","reference":"ASTM A-1038-19","norm_bases":["ASTM A-1038-19"],"lab_section":"Laboratorium Badawcze (MT2)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby hutnicze i odlewnicze o dużych gabarytach Twardość\nMetoda UCI/ Pomiar twardości poprzez pomiar powierzchni odcisku metodą ultradźwiękową ASTM A-1038-19 Wyroby hutnicze i odlewnicze o duzych gabarytach Twardosc\nMetoda UCI/ Pomiar twardosci poprzez pomiar powierzchni odcisku metoda ultradzwiekowa ASTM A-1038-19","categories":["other"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory (MT2)","methodology_en":"Hardness","search_en":"Large-size metallurgical and foundry products Hardness UCI method/ Hardness measurement by measuring the indentation area using the ultrasonic method Testing Laboratory (MT2) ASTM A-1038-19","technique_en":"UCI method/ Hardness measurement by measuring the indentation area using the ultrasonic method","test_object_en":"Large-size metallurgical and foundry products","lab_section_zh":"检测实验室（MT2）","methodology_zh":"硬度","search_zh":"硬度 检测实验室（MT2） ASTM A-1038-19"},{"_id":"6a7d7442ec6a53014a487730","lab_id":"69ad52a3de79e566650fb117","country":"PL","accr_number":"AB 099","accr_body":"PCA","test_object":"Wyroby hutnicze i odlewnicze o dużych gabarytach","methodology":"Twardość HL","parameters":[{"name":"Zakres","range":"D"}],"technique":"Metoda Leeb’a","techniques":["Metoda Leeb’a"],"computed":[],"activity":"Twardość HL\nZakres D\nMetoda Leeb’a","reference":"ASTM A956/A956M-22","norm_bases":["ASTM A956/A956M-22"],"lab_section":"Laboratorium Badawcze (MT2)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby hutnicze i odlewnicze o dużych gabarytach Twardość HL\nZakres D\nMetoda Leeb’a ASTM A956/A956M-22 Wyroby hutnicze i odlewnicze o duzych gabarytach Twardosc HL\nZakres D\nMetoda Leeb’a ASTM A956/A956M-22","categories":["other"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory (MT2)","methodology_en":"HL hardness","parameters_en":[{"name":"Range","range":"D"}],"search_en":"Large-size metallurgical and foundry products HL hardness Leeb method Testing Laboratory (MT2) Range ASTM A956/A956M-22","technique_en":"Leeb method","test_object_en":"Large-size metallurgical and foundry products","parameters_zh":[{"name":"范围","range":"D"}],"search_zh":"检测实验室（MT2） 范围 ASTM A956/A956M-22","lab_section_zh":"检测实验室（MT2）"},{"_id":"6a7d7442ec6a53014a487731","lab_id":"69ad52a3de79e566650fb117","country":"PL","accr_number":"AB 099","accr_body":"PCA","test_object":"Stalowe wyroby hutnicze i wyroby konstrukcyjne","methodology":"Baza Fe","parameters":[{"name":"Zawartość: C, Si, Mn, P, S, Cr, Ni, Mo, V, Al, W, Co, Nb, Ti, Cu"},{"name":"C","range":"(0,045 – 1,38) %"},{"name":"Si","range":"(0,1 – 2,28) %"},{"name":"Mn","range":"(0,29 – 5,8) %"},{"name":"P","range":"(0,01 – 0,04)%"},{"name":"S","range":"(0,002 – 0,16)%"},{"name":"Cr","range":"(0,12 – 26,3) %"},{"name":"Ni","range":"(0,073 – 19,6) %"},{"name":"Mo","range":"(0,02 – 4,1) %"},{"name":"V","range":"(0,03 – 0,5) %"},{"name":"Al","range":"(0,007 – 1,5) %"},{"name":"W","range":"(0,03 – 1,00) %"},{"name":"Co","range":"(0,01 – 0,25) %"},{"name":"Nb","range":"(0,01 – 1,1) %"},{"name":"Ti","range":"(0,01 – 1,0) %"},{"name":"Cu","range":"(0,06 – 2,9) %"}],"technique":"Metoda spektrometrii emisyjnej ze wzbudzeniem iskrowym","techniques":["Metoda spektrometrii emisyjnej ze wzbudzeniem iskrowym"],"computed":[],"activity":"Baza Fe\nZakres:\nZawartość: C, Si, Mn, P, S, Cr, Ni, Mo, V, Al, W, Co, Nb, Ti, Cu\nC (0,045 – 1,38) %\nSi (0,1 – 2,28) %\nMn (0,29 – 5,8) %\nP (0,01 – 0,04)%\nS (0,002 – 0,16)%\nCr (0,12 – 26,3) %\nNi (0,073 – 19,6) %\nMo (0,02 – 4,1) %\nV (0,03 – 0,5) %\nAl (0,007 – 1,5) %\nW (0,03 – 1,00) %\nCo (0,01 – 0,25) %\nNb (0,01 – 1,1) %\nTi (0,01 – 1,0) %\nCu (0,06 – 2,9) %\nMetoda spektrometrii emisyjnej ze wzbudzeniem iskrowym","reference":"MT/I-105 wydanie 6 Data wydania 20-01-2023","norm_bases":["MT/I-105 wydanie 6 Data wydania 20-01-2023"],"lab_section":"Laboratorium Badawcze (MT2)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stalowe wyroby hutnicze i wyroby konstrukcyjne Baza Fe\nZakres:\nZawartość: C, Si, Mn, P, S, Cr, Ni, Mo, V, Al, W, Co, Nb, Ti, Cu\nC (0,045 – 1,38) %\nSi (0,1 – 2,28) %\nMn (0,29 – 5,8) %\nP (0,01 – 0,04)%\nS (0,002 – 0,16)%\nCr (0,12 – 26,3) %\nNi (0,073 – 19,6) %\nMo (0,02 – 4,1) %\nV (0,03 – 0,5) %\nAl (0,007 – 1,5) %\nW (0,03 – 1,00) %\nCo (0,01 – 0,25) %\nNb (0,01 – 1,1) %\nTi (0,01 – 1,0) %\nCu (0,06 – 2,9) %\nMetoda spektrometrii emisyjnej ze wzbudzeniem iskrowym MT/I-105 wydanie 6 Data wydania 20-01-2023 Stalowe wyroby hutnicze i wyroby konstrukcyjne Baza Fe\nZakres:\nZawartosc: C, Si, Mn, P, S, Cr, Ni, Mo, V, Al, W, Co, Nb, Ti, Cu\nC (0,045 – 1,38) %\nSi (0,1 – 2,28) %\nMn (0,29 – 5,8) %\nP (0,01 – 0,04)%\nS (0,002 – 0,16)%\nCr (0,12 – 26,3) %\nNi (0,073 – 19,6) %\nMo (0,02 – 4,1) %\nV (0,03 – 0,5) %\nAl (0,007 – 1,5) %\nW (0,03 – 1,00) %\nCo (0,01 – 0,25) %\nNb (0,01 – 1,1) %\nTi (0,01 – 1,0) %\nCu (0,06 – 2,9) %\nMetoda spektrometrii emisyjnej ze wzbudzeniem iskrowym MT/I-105 wydanie 6 Data wydania 20-01-2023","categories":["materials"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory (MT2)","methodology_en":"Fe base","parameters_en":[{"name":"Content: C, Si, Mn, P, S, Cr, Ni, Mo, V, Al, W, Co, Nb, Ti, Cu"},{"name":"C","range":"(0,045 – 1,38) %"},{"name":"Si","range":"(0,1 – 2,28) %"},{"name":"Mn","range":"(0,29 – 5,8) %"},{"name":"P","range":"(0,01 – 0,04)%"},{"name":"S","range":"(0,002 – 0,16)%"},{"name":"Cr","range":"(0,12 – 26,3) %"},{"name":"Ni","range":"(0,073 – 19,6) %"},{"name":"Mo","range":"(0,02 – 4,1) %"},{"name":"V","range":"(0,03 – 0,5) %"},{"name":"Al","range":"(0,007 – 1,5) %"},{"name":"W","range":"(0,03 – 1,00) %"},{"name":"Co","range":"(0,01 – 0,25) %"},{"name":"Nb","range":"(0,01 – 1,1) %"},{"name":"Ti","range":"(0,01 – 1,0) %"},{"name":"Cu","range":"(0,06 – 2,9) %"}],"search_en":"Steel mill products and structural products Fe base Emission spectrometry method with spark excitation Testing Laboratory (MT2) Content: C, Si, Mn, P, S, Cr, Ni, Mo, V, Al, W, Co, Nb, Ti, Cu C Si Mn P S Cr Ni Mo V Al W Co Nb Ti Cu MT/I-105 wydanie 6 Data wydania 20-01-2023","technique_en":"Emission spectrometry method with spark excitation","test_object_en":"Steel mill products and structural products","parameters_zh":[{"name":"Zawartość: C, Si, Mn, P, S, Cr, Ni, Mo, V, Al, W, Co, Nb, Ti, Cu"},{"name":"C","range":"(0,045 – 1,38) %"},{"name":"Si","range":"(0,1 – 2,28) %"},{"name":"Mn","range":"(0,29 – 5,8) %"},{"name":"P","range":"(0,01 – 0,04)%"},{"name":"S","range":"(0,002 – 0,16)%"},{"name":"Cr","range":"(0,12 – 26,3) %"},{"name":"Ni","range":"(0,073 – 19,6) %"},{"name":"Mo","range":"(0,02 – 4,1) %"},{"name":"V","range":"(0,03 – 0,5) %"},{"name":"Al","range":"(0,007 – 1,5) %"},{"name":"W","range":"(0,03 – 1,00) %"},{"name":"Co","range":"(0,01 – 0,25) %"},{"name":"Nb","range":"(0,01 – 1,1) %"},{"name":"Ti","range":"(0,01 – 1,0) %"},{"name":"Cu","range":"(0,06 – 2,9) %"}],"search_zh":"钢制冶金制品与结构制品 检测实验室（MT2） C Si Mn P S Cr Ni Mo V Al Co Ti Cu MT/I-105 wydanie 6 Data wydania 20-01-2023","lab_section_zh":"检测实验室（MT2）","test_object_zh":"钢制冶金制品与结构制品"},{"_id":"6a7d7442ec6a53014a487732","lab_id":"69ad52a3de79e566650fb117","country":"PL","accr_number":"AB 099","accr_body":"PCA","test_object":"Sprężyny walcowe i talerzowe","methodology":"Charakterystyka sprężyn","parameters":[{"name":"Zakres","range":"siła, ugięcie, sztywność"}],"technique":null,"techniques":[],"computed":[],"activity":"Charakterystyka sprężyn\nZakres siła, ugięcie, sztywność","reference":"PN-88/M-80700 | PN-73/M-80707","norm_bases":["PN-88/M-80700","PN-73/M-80707"],"lab_section":"Laboratorium Badawcze (MT2)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sprężyny walcowe i talerzowe Charakterystyka sprężyn\nZakres siła, ugięcie, sztywność PN-88/M-80700 | PN-73/M-80707 Sprezyny walcowe i talerzowe Charakterystyka sprezyn\nZakres sila, ugiecie, sztywnosc PN-88/M-80700 | PN-73/M-80707","categories":["other"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory (MT2)","methodology_en":"Spring characteristics","parameters_en":[{"name":"Range","range":"siła, ugięcie, sztywność"}],"search_en":"Helical and disc springs Spring characteristics Testing Laboratory (MT2) Range PN-88/M-80700 | PN-73/M-80707","test_object_en":"Helical and disc springs","parameters_zh":[{"name":"范围","range":"siła, ugięcie, sztywność"}],"search_zh":"检测实验室（MT2） 范围 PN-88/M-80700 | PN-73/M-80707","lab_section_zh":"检测实验室（MT2）"},{"_id":"6a7d7442ec6a53014a487733","lab_id":"69ad52a3de79e566650fb117","country":"PL","accr_number":"AB 099","accr_body":"PCA","test_object":"Urządzenia wytwarzające lub przenoszące obciążenia rozciągające i ściskające","methodology":"Siła do +/- 1000 kN","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Siła do +/- 1000 kN","reference":"MT/I-127, wydanie 6, Data wydania 10.05.2023","norm_bases":["MT/I-127, wydanie 6, Data wydania 10.05.2023"],"lab_section":"Laboratorium Badawcze (MT2)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia wytwarzające lub przenoszące obciążenia rozciągające i ściskające Siła do +/- 1000 kN MT/I-127, wydanie 6, Data wydania 10.05.2023 Urzadzenia wytwarzajace lub przenoszace obciazenia rozciagajace i sciskajace Sila do +/- 1000 kN MT/I-127, wydanie 6, Data wydania 10.05.2023","categories":["other"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory (MT2)","methodology_en":"Force up to +/- 1000 kN","search_en":"Devices generating or transmitting tensile and compressive loads Force up to +/- 1000 kN Testing Laboratory (MT2) MT/I-127, wydanie 6, Data wydania 10.05.2023","test_object_en":"Devices generating or transmitting tensile and compressive loads","lab_section_zh":"检测实验室（MT2）","search_zh":"检测实验室（MT2） MT/I-127, wydanie 6, Data wydania 10.05.2023"},{"_id":"6a7d7442ec6a53014a487734","lab_id":"69ad52a3de79e566650fb117","country":"PL","accr_number":"AB 099","accr_body":"PCA","test_object":"Wyroby z metali i niemetali","methodology":"Pomiary długości (0 – 1200) mm","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pomiary długości (0 – 1200) mm","reference":"MT/I-223 wyd.6 z dnia 29.03.2019 MT/I-224 wyd.8 z dnia 29.03.2019 MT/I-225 wyd.7 z dnia 29.03.2023 MT/I-226 wyd.4 z dnia 29.03.2019 MT/I-227 wyd.6 z dnia 29.03.2019 MT/I-228 wyd.6 z dnia 29.03.2019","norm_bases":["MT/I-223 wyd.6 z dnia 29.03.2019 MT/I-224 wyd.8 z dnia 29.03.2019 MT/I-225 wyd.7 z dnia 29.03.2023 MT/I-226 wyd.4 z dnia 29.03.2019 MT/I-227 wyd.6 z dnia 29.03.2019 MT/I-228 wyd.6 z dnia 29.03.2019"],"lab_section":"Laboratorium Długości i Kąta (MT3)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby z metali i niemetali Pomiary długości (0 – 1200) mm MT/I-223 wyd.6 z dnia 29.03.2019 MT/I-224 wyd.8 z dnia 29.03.2019 MT/I-225 wyd.7 z dnia 29.03.2023 MT/I-226 wyd.4 z dnia 29.03.2019 MT/I-227 wyd.6 z dnia 29.03.2019 MT/I-228 wyd.6 z dnia 29.03.2019 Wyroby z metali i niemetali Pomiary dlugosci (0 – 1200) mm MT/I-223 wyd.6 z dnia 29.03.2019 MT/I-224 wyd.8 z dnia 29.03.2019 MT/I-225 wyd.7 z dnia 29.03.2023 MT/I-226 wyd.4 z dnia 29.03.2019 MT/I-227 wyd.6 z dnia 29.03.2019 MT/I-228 wyd.6 z dnia 29.03.2019","categories":["materials"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Length and Angle Laboratory (MT3)","methodology_en":"Length measurements (0 – 1200) mm","search_en":"Products made of metals and non-metals Length measurements (0 – 1200) mm Length and Angle Laboratory (MT3) MT/I-223 wyd.6 z dnia 29.03.2019 MT/I-224 wyd.8 z dnia 29.03.2019 MT/I-225 wyd.7 z dnia 29.03.2023 MT/I-226 wyd.4 z dnia 29.03.2019 MT/I-227 wyd.6 z dnia 29.03.2019 MT/I-228 wyd.6 z dnia 29.03.2019","test_object_en":"Products made of metals and non-metals"},{"_id":"6a7d7442ec6a53014a487735","lab_id":"69ad52a3de79e566650fb117","country":"PL","accr_number":"AB 099","accr_body":"PCA","test_object":"Wyroby z metali i niemetali","methodology":"Pomiary kąta (0 – 360) °","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pomiary kąta (0 – 360) °","reference":"MT/I-224 wyd.8 z dnia 29.03.2019 MT/I-225 wyd.7 z dnia 29.03.2023","norm_bases":["MT/I-224 wyd.8 z dnia 29.03.2019 MT/I-225 wyd.7 z dnia 29.03.2023"],"lab_section":"Laboratorium Długości i Kąta (MT3)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby z metali i niemetali Pomiary kąta (0 – 360) ° MT/I-224 wyd.8 z dnia 29.03.2019 MT/I-225 wyd.7 z dnia 29.03.2023 Wyroby z metali i niemetali Pomiary kata (0 – 360) ° MT/I-224 wyd.8 z dnia 29.03.2019 MT/I-225 wyd.7 z dnia 29.03.2023","categories":["materials"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Length and Angle Laboratory (MT3)","methodology_en":"Angle measurements (0 – 360) °","search_en":"Products made of metals and non-metals Angle measurements (0 – 360) ° Length and Angle Laboratory (MT3) MT/I-224 wyd.8 z dnia 29.03.2019 MT/I-225 wyd.7 z dnia 29.03.2023","test_object_en":"Products made of metals and non-metals"}],"has_pdf":true}