{"lab":{"_id":"69ad52a3de79e566650fb107","accr_number":"AB 079","country":"PL","accr_body":"PCA","address":"LABORATORIUM BADAWCZE, ul. Chwaszczyńska 180, 81-571 Gdynia","categories":["food","materials","water","petro","microbiology","environment","pharma"],"city":"Gdynia","imported_at":"2026-03-08T10:42:43.265Z","methods_count":631,"name":"J.S. HAMILTON POLAND Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_079.pdf"],"scope_summary":"","search_text":"j.s. hamilton poland sp. z o.o. laboratorium badawcze, ul. chwaszczyńska 180, 81-571 gdynia petro food pharma materials other water environment automotive microbiology electronics metrology","status":"active","updated_at":"2026-03-08T14:50:09.263Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T07:46:01.502Z","parse_date":"2026-08-13T07:46:01.502Z","parse_source":"agent-claude-code","email_confidence":"high","email_mx":true,"email_source":"https://hamilton.com.pl/en/contact/","fields_of_testing":[{"codes":"B/1, B/4, B/17, B/22, B/42, B/55, B/57","pl":"Badania biologiczne i biochemiczne – produkty rolne, wyroby chemiczne, wyroby inne, żywność, kosmetyki, pasze dla zwierząt, obiekty z obszaru produkcji żywności","en":"Biological and biochemical tests of agricultural products – including animal feedstuffs, chemical products, other products, food, cosmetics, fertilizers, animal feedstuffs, objects from food production area"},{"codes":"C/1/P, C/28/P, C/29/P, C/30/P, C/31/P, C/32/P","pl":"Badania chemiczne i pobieranie próbek - produkty rolne, woda, woda do spożycia przez ludzi, ścieki, gleba, osady, odpady","en":"Chemical tests and sampling of feedstuffs, water, drinking water, sewage, soil, sediments, waste"},{"codes":"C/4, C/6, C/10, C/17, C/18, C/21, C/22, C/23, C/25, C/42, C/43, C/44, C/45, C/49, C/53, C/54, C/55","pl":"Badania chemiczne - wyroby chemiczne, wyroby i wyposażenie elektryczne, paliwa, wyroby inne, papier, tektura, wyroby z tworzyw sztucznych i gumy, żywność, tekstylia i skóra, zabawki, kosmetyki, nawozy, środki wspomagające uprawę roślin, farby i lakiery, materiały opakowaniowe, wyroby i wyposażenie telekomunikacyjne i elektroniczne, wyroby i wyposażenie elektroniczne, pasze dla zwierząt","en":"Chemical tests of agricultural products – chemical products, electrical, products and equipment, fuels (gas, liquid, solid), other products, paper, cardboard, plastic and rubber products, foods, textiles, toys, cosmetics, fertilizers, plant growth substances, paints and lacquers, packaging materials, electrical, telecommunication and electronic products and equipment, electronic equipment, animal feedstuffs"},{"codes":"K/9/P, K/28/P, K/29/P, K/30/P, K/32/P","pl":"Badania mikrobiologiczne i pobieranie próbek – powietrze, woda, woda do spożycia przez ludzi, ścieki, osady","en":"Microbiological tests and sampling of air, water, drinking water, sewage, sediments"},{"codes":"K/1, K/3, K/4, K/9, K/10, K/12, K/17, K/18, K/21, K/22, K/27, K/42, K/49, K/55, K/57","pl":"Badania mikrobiologiczne - produkty rolne, obiekty i materiały biologiczne przeznaczone do badań, wyroby chemiczne, paliwa ciekłe, szkło i ceramika, wyroby inne, papier, tektura, wyroby z tworzyw sztucznych i gumy, żywność, drewno, kosmetyki, materiały opakowaniowe, pasze dla zwierząt, obiekty z obszaru produkcji żywności","en":"Microbiological tests of agricultural products, biological materials for testing, chemical products, liquid fuels, glass and ceramics, other products, paper, cardboard, plastic and rubber products, food, wood, cosmetics, packaging materials, animal feedstuffs, objects from food production area"},{"codes":"N/28/P, N/29P, N/30/P, N/31/P, N/32/P","pl":"Badania właściwości fizycznych i pobieranie próbek – woda, woda do spożycia przez ludzi, ścieki, gleba, osady, odpady","en":"Tests of physical properties and sampling of water, drinking water, sewage, soil, sediments, waste"},{"codes":"N/1, N/4; N/10, N/18, N/21, N/22, N/23, N/25, N/42, N/49, N/55","pl":"Badania właściwości fizycznych - produkty rolne, wyroby chemiczne, paliwa, papier, tektura, wyroby z tworzyw sztucznych i gumy, żywność, tekstylia, zabawki, kosmetyki, materiały opakowaniowe, pasze dla zwierząt","en":"Tests of physical properties of agricultural products, chemical products, fuels, paper, cardboard, plastic and rubber products, food, textiles, toys, cosmetics, packaging materials, animal feedstuffs"},{"codes":"Q/28/P, Q/29/P","pl":"Badania sensoryczne i pobieranie próbek – woda, woda do spożycia przez ludzi","en":"Sensory tests and sampling of water, drinking water"},{"codes":"Q/1, Q/4, Q/6, Q/10, Q/12, Q/17, Q/18, Q/21, Q/22, Q/42, Q/49","pl":"Badania sensoryczne - produkty rolne, wyroby chemiczne, wyroby elektryczne, paliwa, szkło i ceramika, wyroby inne, papier, tektura, wyroby z tworzyw sztucznych i gumy, żywność, kosmetyki, materiały opakowaniowe","en":"Sensory tests of agricultural products, chemical products, electrical products, fuels, glass and ceramics, other products, paper, cardboard, plastic and rubber products, food, cosmetics, packaging materials"}],"issue":{"no":"71","date":"15.05.2026"},"map_coord":[54.457713,18.447425],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM BADAWCZE","address":"ul. Chwaszczyńska 180","city":null,"postal":null},{"name":"Pracownia Paliw Gdynia","address":"ul. Chwaszczyńska 180, 81-571 Gdynia","city":"Gdynia","postal":"81-571"},{"name":"Pracownia Paliw Tychy","address":"ul. Goździków 1, 43-100 Tychy","city":"Tychy","postal":"43-100"},{"name":"Pracownia Mikrobiologii Gdynia","address":"ul. Chwaszczyńska 180, 81-571 Gdynia","city":"Gdynia","postal":"81-571"},{"name":"Pracownia Biologii Molekularnej Tychy","address":"ul. Goździków 1, 43-100 Tychy","city":"Tychy","postal":"43-100"},{"name":"Pracownia Mikrobiologii Przeźmierowo","address":"ul. Rzemieślnicza 9, 62-081 Przeźmierowo","city":"Przeźmierowo","postal":"62-081"},{"name":"Pracownia Mikrobiologii Tychy","address":"ul. Goździków 1, 43-100 Tychy","city":"Tychy","postal":"43-100"},{"name":"Pracownia Mikrobiologii Kosmetyków Tychy","address":"ul. Goździków 1, 43-100 Tychy","city":"Tychy","postal":"43-100"},{"name":"Pracownia Mikrobiologii Maków Mazowiecki","address":"ul. Przemysłowa 5, 06-200 Maków Mazowiecki","city":"Maków Mazowiecki","postal":"06-200"},{"name":"Pracownia Mikrobiologii Aleksandrów Łódzki","address":"ul. Ignacego Daszyńskiego 116, 95-070 Aleksandrów Łódzki","city":"Aleksandrów Łódzki","postal":"95-070"},{"name":"Pracownia Analiz Sensorycznych","address":"ul. Chwaszczyńska 180, 81-571 Gdynia","city":"Gdynia","postal":"81-571"},{"name":"Pracownia Analiz Witamin i Dioksyn","address":"ul. Chwaszczyńska 180, 81-571 Gdynia","city":"Gdynia","postal":"81-571"},{"name":"Pracownia Analiz Instrumentalnych","address":"ul. Chwaszczyńska 180, 81-571 Gdynia","city":"Gdynia","postal":"81-571"},{"name":"Pracownia Spektrometrii","address":"ul. Chwaszczyńska 180, 81-571 Gdynia","city":"Gdynia","postal":"81-571"},{"name":"Pracownia Analiz Klasycznych","address":"ul. Chwaszczyńska 180, 81-571 Gdynia","city":"Gdynia","postal":"81-571"},{"name":"Pracownia Analiz Wartości Odżywczej","address":"ul. Chwaszczyńska 180, 81-571 Gdynia","city":"Gdynia","postal":"81-571"},{"name":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","address":"ul. Chwaszczyńska 180, 81-571 Gdynia","city":"Gdynia","postal":"81-571"},{"name":"Pracownia Analiz Środowiska Gdynia","address":"ul. Chwaszczyńska 180, 81-571 Gdynia","city":"Gdynia","postal":"81-571"},{"name":"Pracownia Analiz Środowiska Zgierz","address":"ul. Aleksandrowska 61A, 95-100 Zgierz","city":"Zgierz","postal":"95-100"},{"name":"Sekcja Poboru Próbek","address":"ul. Chwaszczyńska 180, 81-571 Gdynia","city":"Gdynia","postal":"81-571"},{"name":"Sekcja Uśredniania Próbek i Analiz Fizycznych","address":"ul. Chwaszczyńska 180, 81-571 Gdynia","city":"Gdynia","postal":"81-571"},{"name":"Sekcja Dermatologii","address":"ul. Bajana 3D, 80-463 Gdańsk","city":"Gdańsk","postal":"80-463"},{"name":"Pracownia Analiz Pozostałości Pestycydów","address":"Słomczyn 80, 05-600 Grójec","city":"Grójec","postal":"05-600"},{"name":"Pracownia Analiz Pozostałości Pestycydów; Słomczyn 80, 05-600 Grójec","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/4ffd0b52d599d27e790e55b03bbe4bc7/AB%20079.pdf","has_en":true,"category_counts":{"food":214,"materials":156,"water":130,"petro":120,"microbiology":100,"environment":79,"other":68,"pharma":37,"electronics":3,"construction":1},"category_scores":{"food":50.44,"materials":26.8,"water":18.61,"petro":15.86,"microbiology":11.01,"environment":6.87,"other":5.09,"pharma":1.51,"electronics":0.01,"construction":0},"has_zh":true,"lab_locations_zh":[{"name":"检测实验室","address":"ul. Chwaszczyńska 180","city":null,"postal":null},{"name":"燃料实验室 Gdynia","address":"ul. Chwaszczyńska 180, 81-571 Gdynia","city":"Gdynia","postal":"81-571"},{"name":"燃料实验室 Tychy","address":"ul. Goździków 1, 43-100 Tychy","city":"Tychy","postal":"43-100"},{"name":"微生物实验室 Gdynia","address":"ul. Chwaszczyńska 180, 81-571 Gdynia","city":"Gdynia","postal":"81-571"},{"name":"蒂黑分子生物学检验室","address":"ul. Goździków 1, 43-100 Tychy","city":"Tychy","postal":"43-100"},{"name":"普热兹米耶罗沃微生物检验室","address":"ul. Rzemieślnicza 9, 62-081 Przeźmierowo","city":"Przeźmierowo","postal":"62-081"},{"name":"微生物实验室 Tychy","address":"ul. Goździków 1, 43-100 Tychy","city":"Tychy","postal":"43-100"},{"name":"蒂黑化妆品微生物检验室","address":"ul. Goździków 1, 43-100 Tychy","city":"Tychy","postal":"43-100"},{"name":"微生物实验室 Maków Mazowiecki","address":"ul. Przemysłowa 5, 06-200 Maków Mazowiecki","city":"Maków Mazowiecki","postal":"06-200"},{"name":"微生物实验室 Aleksandrów Łódzki","address":"ul. Ignacego Daszyńskiego 116, 95-070 Aleksandrów Łódzki","city":"Aleksandrów Łódzki","postal":"95-070"},{"name":"感官分析检验室","address":"ul. Chwaszczyńska 180, 81-571 Gdynia","city":"Gdynia","postal":"81-571"},{"name":"维生素与二噁英分析检验室","address":"ul. Chwaszczyńska 180, 81-571 Gdynia","city":"Gdynia","postal":"81-571"},{"name":"仪器分析检验室","address":"ul. Chwaszczyńska 180, 81-571 Gdynia","city":"Gdynia","postal":"81-571"},{"name":"光谱检验室","address":"ul. Chwaszczyńska 180, 81-571 Gdynia","city":"Gdynia","postal":"81-571"},{"name":"经典分析实验室","address":"ul. Chwaszczyńska 180, 81-571 Gdynia","city":"Gdynia","postal":"81-571"},{"name":"营养价值分析实验室","address":"ul. Chwaszczyńska 180, 81-571 Gdynia","city":"Gdynia","postal":"81-571"},{"name":"非食品产品与包装检测实验室","address":"ul. Chwaszczyńska 180, 81-571 Gdynia","city":"Gdynia","postal":"81-571"},{"name":"环境分析实验室 Gdynia","address":"ul. Chwaszczyńska 180, 81-571 Gdynia","city":"Gdynia","postal":"81-571"},{"name":"环境分析实验室 Zgierz","address":"ul. Aleksandrowska 61A, 95-100 Zgierz","city":"Zgierz","postal":"95-100"},{"name":"采样科","address":"ul. Chwaszczyńska 180, 81-571 Gdynia","city":"Gdynia","postal":"81-571"},{"name":"样品均化与物理分析科","address":"ul. Chwaszczyńska 180, 81-571 Gdynia","city":"Gdynia","postal":"81-571"},{"name":"Sekcja Dermatologii","address":"ul. Bajana 3D, 80-463 Gdańsk","city":"Gdańsk","postal":"80-463"},{"name":"农药残留分析检验室","address":"Słomczyn 80, 05-600 Grójec","city":"Grójec","postal":"05-600"},{"name":"Pracownia Analiz Pozostałości Pestycydów; Słomczyn 80, 05-600 Grójec","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7d76396040ebab2620d277","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Indeks cetanowy (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks cetanowy (z obliczeń)","reference":"PN-EN ISO 4264:2018-08","norm_bases":["PN-EN ISO 4264:2018-08"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Indeks cetanowy (z obliczeń) PN-EN ISO 4264:2018-08 Paliwa ciekle: olej napedowy, olej opalowy lekki Indeks cetanowy (z obliczen) PN-EN ISO 4264:2018-08","categories":["petro"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Cetane index (calculated)","search_en":"Liquid fuels: diesel fuel, light fuel oil Cetane index (calculated) Fuels Laboratory Gdynia PN-EN ISO 4264:2018-08","test_object_en":"Liquid fuels: diesel fuel, light fuel oil","lab_section_zh":"燃料实验室 Gdynia","search_zh":"液体燃料：柴油、轻质燃料油 十六烷指数（计算值） 燃料实验室 Gdynia PN-EN ISO 4264:2018-08","test_object_zh":"液体燃料：柴油、轻质燃料油","methodology_zh":"十六烷指数（计算值）"},{"_id":"6a7d76396040ebab2620d278","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki, paliwo żeglugowe","methodology":"Korodujące działanie na miedź","parameters":[{"name":"klasa korozji","range":"(1 – 4)"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Korodujące działanie na miedź\nklasa korozji (1 – 4)\nMetoda wizualna","reference":"PN-EN ISO 2160:2004","norm_bases":["PN-EN ISO 2160:2004"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki, paliwo żeglugowe Korodujące działanie na miedź\nklasa korozji (1 – 4)\nMetoda wizualna PN-EN ISO 2160:2004 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, olej opalowy lekki, paliwo zeglugowe Korodujace dzialanie na miedz\nklasa korozji (1 – 4)\nMetoda wizualna PN-EN ISO 2160:2004","categories":["petro","materials"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Copper strip corrosion","parameters_en":[{"name":"corrosion class","range":"(1 – 4)"}],"search_en":"Liquid fuels: diesel fuel, unleaded petrol, light fuel oil, marine fuel Copper strip corrosion Visual method Fuels Laboratory Gdynia corrosion class PN-EN ISO 2160:2004","technique_en":"Visual method","test_object_en":"Liquid fuels: diesel fuel, unleaded petrol, light fuel oil, marine fuel","search_zh":"液体燃料：柴油、无铅汽油、轻质燃料油、船用燃料 铜片腐蚀 目视法 燃料实验室 Gdynia 腐蚀等级 PN-EN ISO 2160:2004","technique_zh":"目视法","lab_section_zh":"燃料实验室 Gdynia","methodology_zh":"铜片腐蚀","parameters_zh":[{"name":"腐蚀等级","range":"(1 – 4)"}],"test_object_zh":"液体燃料：柴油、无铅汽油、轻质燃料油、船用燃料"},{"_id":"6a7d76396040ebab2620d279","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, paliwo żeglugowe","methodology":"Lepkość kinematyczna w temp. 40 °C, 50 °C i 100 °C","parameters":[{"name":"Zakres","range":"(2,000 – 50,00) mm2/s"},{"name":"Lepkość dynamiczna (z obliczeń)"}],"technique":"Metoda kapilarna","techniques":["Metoda kapilarna"],"computed":[],"activity":"Lepkość kinematyczna w temp. 40 °C, 50 °C i 100 °C\nZakres:\nZakres (2,000 – 50,00) mm2/s\nLepkość dynamiczna (z obliczeń)\nMetoda kapilarna","reference":"PN-EN ISO 3104:2024-01 Procedura A","norm_bases":["PN-EN ISO 3104:2024-01 Procedura A"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, paliwo żeglugowe Lepkość kinematyczna w temp. 40 °C, 50 °C i 100 °C\nZakres:\nZakres (2,000 – 50,00) mm2/s\nLepkość dynamiczna (z obliczeń)\nMetoda kapilarna PN-EN ISO 3104:2024-01 Procedura A Paliwa ciekle: olej napedowy, olej opalowy lekki, olej opalowy ciezki, paliwo zeglugowe Lepkosc kinematyczna w temp. 40 °C, 50 °C i 100 °C\nZakres:\nZakres (2,000 – 50,00) mm2/s\nLepkosc dynamiczna (z obliczen)\nMetoda kapilarna PN-EN ISO 3104:2024-01 Procedura A","categories":["petro"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Kinematic viscosity at 40 °C, 50 °C and 100 °C","parameters_en":[{"name":"Range","range":"(2,000 – 50,00) mm2/s"},{"name":"Dynamic viscosity (calculated)"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil, heavy fuel oil, marine fuel Kinematic viscosity at 40 °C, 50 °C and 100 °C Capillary method Fuels Laboratory Gdynia Range Dynamic viscosity (calculated) PN-EN ISO 3104:2024-01 Procedura A","technique_en":"Capillary method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil, heavy fuel oil, marine fuel","parameters_zh":[{"name":"范围","range":"(2,000 – 50,00) mm2/s"},{"name":"动力黏度（由计算得出）"}],"search_zh":"液体燃料：柴油、轻质燃料油、重燃料油、船用燃料 毛细管法 燃料实验室 Gdynia 范围 动力黏度（由计算得出） PN-EN ISO 3104:2024-01 Procedura A","lab_section_zh":"燃料实验室 Gdynia","technique_zh":"毛细管法","test_object_zh":"液体燃料：柴油、轻质燃料油、重燃料油、船用燃料"},{"_id":"6a7d76396040ebab2620d27a","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, paliwo żeglugowe","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,003 – 0,100) % (m/m)"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (0,003 – 0,100) % (m/m)\nMetoda miareczkowania kulometrycznego","reference":"PN-EN ISO 12937:2005+Ap1:2021-11","norm_bases":["PN-EN ISO 12937:2005+Ap1:2021-11"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, paliwo żeglugowe Zawartość wody\nZakres (0,003 – 0,100) % (m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11 Paliwa ciekle: olej napedowy, olej opalowy lekki, paliwo zeglugowe Zawartosc wody\nZakres (0,003 – 0,100) % (m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11","categories":["petro","water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(0,003 – 0,100) % (m/m)"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil, marine fuel Water content Coulometric titration method Fuels Laboratory Gdynia Range PN-EN ISO 12937:2005+Ap1:2021-11","technique_en":"Coulometric titration method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil, marine fuel","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,003 – 0,100) % (m/m)"}],"search_zh":"液体燃料：柴油、轻质燃料油、船用燃料 水分含量 库仑滴定法 燃料实验室 Gdynia 范围 PN-EN ISO 12937:2005+Ap1:2021-11","lab_section_zh":"燃料实验室 Gdynia","technique_zh":"库仑滴定法","test_object_zh":"液体燃料：柴油、轻质燃料油、船用燃料"},{"_id":"6a7d76396040ebab2620d27b","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, paliwo żeglugowe","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(6,0 – 30,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (6,0 – 30,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-1:2024-11","norm_bases":["PN-EN 12662-1:2024-11"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, paliwo żeglugowe Zawartość zanieczyszczeń\nZakres (6,0 – 30,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11 Paliwa ciekle: olej napedowy, olej opalowy lekki, paliwo zeglugowe Zawartosc zanieczyszczen\nZakres (6,0 – 30,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11","categories":["petro"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Impurity content","parameters_en":[{"name":"Range","range":"(6,0 – 30,0) mg/kg"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil, marine fuel Impurity content Gravimetric method Fuels Laboratory Gdynia Range PN-EN 12662-1:2024-11","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil, marine fuel","parameters_zh":[{"name":"范围","range":"(6,0 – 30,0) mg/kg"}],"search_zh":"液体燃料：柴油、轻质燃料油、船用燃料 杂质含量 重量法 燃料实验室 Gdynia 范围 PN-EN 12662-1:2024-11","technique_zh":"重量法","lab_section_zh":"燃料实验室 Gdynia","methodology_zh":"杂质含量","test_object_zh":"液体燃料：柴油、轻质燃料油、船用燃料"},{"_id":"6a7d76396040ebab2620d27c","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, paliwo żeglugowe","methodology":"Temperatura mętnienia","parameters":[{"name":"Zakres","range":"(-40 – 0) °C"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Temperatura mętnienia\nZakres (-40 – 0) °C\nMetoda wizualna","reference":"PN-EN ISO 3015:2019-06","norm_bases":["PN-EN ISO 3015:2019-06"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, paliwo żeglugowe Temperatura mętnienia\nZakres (-40 – 0) °C\nMetoda wizualna PN-EN ISO 3015:2019-06 Paliwa ciekle: olej napedowy, olej opalowy lekki, paliwo zeglugowe Temperatura metnienia\nZakres (-40 – 0) °C\nMetoda wizualna PN-EN ISO 3015:2019-06","categories":["petro"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Cloud point","parameters_en":[{"name":"Range","range":"(-40 – 0) °C"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil, marine fuel Cloud point Visual method Fuels Laboratory Gdynia Range PN-EN ISO 3015:2019-06","technique_en":"Visual method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil, marine fuel","parameters_zh":[{"name":"范围","range":"(-40 – 0) °C"}],"search_zh":"液体燃料：柴油、轻质燃料油、船用燃料 浊点 目视法 燃料实验室 Gdynia 范围 PN-EN ISO 3015:2019-06","technique_zh":"目视法","lab_section_zh":"燃料实验室 Gdynia","methodology_zh":"浊点","test_object_zh":"液体燃料：柴油、轻质燃料油、船用燃料"},{"_id":"6a7d76396040ebab2620d27d","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, paliwo żeglugowe","methodology":"Temperatura płynięcia","parameters":[{"name":"Zakres","range":"(-33 – +30) °C"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Temperatura płynięcia\nZakres (-33 – +30) °C\nMetoda wizualna","reference":"PN-EN ISO 3016:2019-06","norm_bases":["PN-EN ISO 3016:2019-06"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, paliwo żeglugowe Temperatura płynięcia\nZakres (-33 – +30) °C\nMetoda wizualna PN-EN ISO 3016:2019-06 Paliwa ciekle: olej napedowy, olej opalowy lekki, olej opalowy ciezki, paliwo zeglugowe Temperatura plyniecia\nZakres (-33 – +30) °C\nMetoda wizualna PN-EN ISO 3016:2019-06","categories":["petro"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Pour point","parameters_en":[{"name":"Range","range":"(-33 – +30) °C"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil, heavy fuel oil, marine fuel Pour point Visual method Fuels Laboratory Gdynia Range PN-EN ISO 3016:2019-06","technique_en":"Visual method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil, heavy fuel oil, marine fuel","parameters_zh":[{"name":"范围","range":"(-33 – +30) °C"}],"search_zh":"液体燃料：柴油、轻质燃料油、重燃料油、船用燃料 倾点 目视法 燃料实验室 Gdynia 范围 PN-EN ISO 3016:2019-06","technique_zh":"目视法","lab_section_zh":"燃料实验室 Gdynia","methodology_zh":"倾点","test_object_zh":"液体燃料：柴油、轻质燃料油、重燃料油、船用燃料"},{"_id":"6a7d76396040ebab2620d27e","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, paliwo żeglugowe","methodology":"Pozostałość po spopieleniu","parameters":[{"name":"Zakres","range":"(0,001 – 0,180) % (m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Pozostałość po spopieleniu\nZakres (0,001 – 0,180) % (m/m)\nMetoda wagowa","reference":"PN-EN ISO 6245:2008","norm_bases":["PN-EN ISO 6245:2008"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, paliwo żeglugowe Pozostałość po spopieleniu\nZakres (0,001 – 0,180) % (m/m)\nMetoda wagowa PN-EN ISO 6245:2008 Paliwa ciekle: olej napedowy, olej opalowy lekki, olej opalowy ciezki, paliwo zeglugowe Pozostalosc po spopieleniu\nZakres (0,001 – 0,180) % (m/m)\nMetoda wagowa PN-EN ISO 6245:2008","categories":["petro"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Residue after incineration","parameters_en":[{"name":"Range","range":"(0,001 – 0,180) % (m/m)"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil, heavy fuel oil, marine fuel Residue after incineration Gravimetric method Fuels Laboratory Gdynia Range PN-EN ISO 6245:2008","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil, heavy fuel oil, marine fuel","parameters_zh":[{"name":"范围","range":"(0,001 – 0,180) % (m/m)"}],"search_zh":"液体燃料：柴油、轻质燃料油、重燃料油、船用燃料 灰化残渣 重量法 燃料实验室 Gdynia 范围 PN-EN ISO 6245:2008","technique_zh":"重量法","lab_section_zh":"燃料实验室 Gdynia","methodology_zh":"灰化残渣","test_object_zh":"液体燃料：柴油、轻质燃料油、重燃料油、船用燃料"},{"_id":"6a7d76396040ebab2620d27f","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy lekki, olej opałowy ciężki, paliwo żeglugowe","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(0,03 – 2,00) % (m/m)"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii (ED-XRF)","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii (ED-XRF)"],"computed":[],"activity":"Zawartość siarki\nZakres (0,03 – 2,00) % (m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii (ED-XRF)","reference":"PN-EN ISO 8754:2007+Ap1:2014-02","norm_bases":["PN-EN ISO 8754:2007+Ap1:2014-02"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy lekki, olej opałowy ciężki, paliwo żeglugowe Zawartość siarki\nZakres (0,03 – 2,00) % (m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii (ED-XRF) PN-EN ISO 8754:2007+Ap1:2014-02 Paliwa ciekle: olej opalowy lekki, olej opalowy ciezki, paliwo zeglugowe Zawartosc siarki\nZakres (0,03 – 2,00) % (m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja energii (ED-XRF) PN-EN ISO 8754:2007+Ap1:2014-02","categories":["petro"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(0,03 – 2,00) % (m/m)"}],"search_en":"Liquid fuels: light heating oil, heavy heating oil, marine fuel Sulfur content Energy-dispersive X-ray fluorescence spectrometry (ED-XRF) Fuels Laboratory Gdynia Range PN-EN ISO 8754:2007+Ap1:2014-02","technique_en":"Energy-dispersive X-ray fluorescence spectrometry (ED-XRF)","test_object_en":"Liquid fuels: light heating oil, heavy heating oil, marine fuel","parameters_zh":[{"name":"范围","range":"(0,03 – 2,00) % (m/m)"}],"search_zh":"硫含量 能量色散X射线荧光光谱法（ED-XRF） 燃料实验室 Gdynia 范围 PN-EN ISO 8754:2007+Ap1:2014-02","lab_section_zh":"燃料实验室 Gdynia","methodology_zh":"硫含量","technique_zh":"能量色散X射线荧光光谱法（ED-XRF）"},{"_id":"6a7d76396040ebab2620d280","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Zawartość żywic","parameters":[{"name":"żywice obecne, żywice przemywane"},{"name":"Zakres","range":"(1,0 – 10,0) mg/100 ml"},{"name":"żywice nieprzemywane","range":"(1,0 – 100,0) mg/100 ml"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość żywic\nZakres:\nżywice obecne, żywice przemywane\nZakres (1,0 – 10,0) mg/100 ml\nżywice nieprzemywane (1,0 – 100,0) mg/100 ml\nMetoda wagowa","reference":"PN-EN ISO 6246:2017-05+A1:2020-03 z wyłączeniem pkt. 8 i 9","norm_bases":["PN-EN ISO 6246:2017-05+A1:2020-03 z wyłączeniem pkt. 8 i 9"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Zawartość żywic\nZakres:\nżywice obecne, żywice przemywane\nZakres (1,0 – 10,0) mg/100 ml\nżywice nieprzemywane (1,0 – 100,0) mg/100 ml\nMetoda wagowa PN-EN ISO 6246:2017-05+A1:2020-03 z wyłączeniem pkt. 8 i 9 Paliwa ciekle: benzyna bezolowiowa Zawartosc zywic\nZakres:\nzywice obecne, zywice przemywane\nZakres (1,0 – 10,0) mg/100 ml\nzywice nieprzemywane (1,0 – 100,0) mg/100 ml\nMetoda wagowa PN-EN ISO 6246:2017-05+A1:2020-03 z wylaczeniem pkt. 8 i 9","categories":["petro"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Gum content","parameters_en":[{"name":"existent gums, washed gums"},{"name":"Range","range":"(1,0 – 10,0) mg/100 ml"},{"name":"unwashed gums","range":"(1,0 – 100,0) mg/100 ml"}],"search_en":"Liquid fuels: unleaded petrol Gum content Gravimetric method Fuels Laboratory Gdynia existent gums, washed gums Range unwashed gums PN-EN ISO 6246:2017-05+A1:2020-03 z wyłączeniem pkt. 8 i 9","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"żywice obecne, żywice przemywane"},{"name":"范围","range":"(1,0 – 10,0) mg/100 ml"},{"name":"żywice nieprzemywane","range":"(1,0 – 100,0) mg/100 ml"}],"search_zh":"液体燃料：无铅汽油 树脂含量 重量法 燃料实验室 Gdynia 范围 PN-EN ISO 6246:2017-05+A1:2020-03 z wyłączeniem pkt. 8 i 9","technique_zh":"重量法","lab_section_zh":"燃料实验室 Gdynia","test_object_zh":"液体燃料：无铅汽油","methodology_zh":"树脂含量"},{"_id":"6a7d76396040ebab2620d281","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Stabilność oksydacyjna","parameters":[{"name":"Zakres","range":"(200 – 600) min"}],"technique":"Metoda okresu indukcyjnego","techniques":["Metoda okresu indukcyjnego"],"computed":[],"activity":"Stabilność oksydacyjna\nZakres (200 – 600) min\nMetoda okresu indukcyjnego","reference":"PN-EN ISO 7536:2011","norm_bases":["PN-EN ISO 7536:2011"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Stabilność oksydacyjna\nZakres (200 – 600) min\nMetoda okresu indukcyjnego PN-EN ISO 7536:2011 Paliwa ciekle: benzyna bezolowiowa Stabilnosc oksydacyjna\nZakres (200 – 600) min\nMetoda okresu indukcyjnego PN-EN ISO 7536:2011","categories":["petro"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Oxidation stability","parameters_en":[{"name":"Range","range":"(200 – 600) min"}],"search_en":"Liquid fuels: unleaded petrol Oxidation stability Induction period method Fuels Laboratory Gdynia Range PN-EN ISO 7536:2011","technique_en":"Induction period method","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"范围","range":"(200 – 600) min"}],"search_zh":"液体燃料：无铅汽油 氧化安定性 诱导期法 燃料实验室 Gdynia 范围 PN-EN ISO 7536:2011","lab_section_zh":"燃料实验室 Gdynia","methodology_zh":"氧化安定性","test_object_zh":"液体燃料：无铅汽油","technique_zh":"诱导期法"},{"_id":"6a7d76396040ebab2620d282","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Prężność par nasyconych powietrzem (ASVP)","parameters":[{"name":"Zakres","range":"(50,0 – 90,0) kPa"}],"technique":"Metoda mini Reid","techniques":["Metoda mini Reid"],"computed":[],"activity":"Prężność par nasyconych powietrzem (ASVP)\nZakres (50,0 – 90,0) kPa\nMetoda mini Reid","reference":"PN-EN 13016-1:2024-11","norm_bases":["PN-EN 13016-1:2024-11"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Prężność par nasyconych powietrzem (ASVP)\nZakres (50,0 – 90,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11 Paliwa ciekle: benzyna bezolowiowa Preznosc par nasyconych powietrzem (ASVP)\nZakres (50,0 – 90,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11","categories":["petro","environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Air saturated vapour pressure (ASVP)","parameters_en":[{"name":"Range","range":"(50,0 – 90,0) kPa"}],"search_en":"Liquid fuels: unleaded petrol Air saturated vapour pressure (ASVP) Mini Reid method Fuels Laboratory Gdynia Range PN-EN 13016-1:2024-11","technique_en":"Mini Reid method","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"范围","range":"(50,0 – 90,0) kPa"}],"search_zh":"液体燃料：无铅汽油 迷你雷德法 燃料实验室 Gdynia 范围 PN-EN 13016-1:2024-11","lab_section_zh":"燃料实验室 Gdynia","test_object_zh":"液体燃料：无铅汽油","technique_zh":"迷你雷德法"},{"_id":"6a7d76396040ebab2620d283","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Równoważnik prężności par suchych (DVPE) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważnik prężności par suchych (DVPE) (z obliczeń)","reference":"PN-EN 13016-1:2024-11","norm_bases":["PN-EN 13016-1:2024-11"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Równoważnik prężności par suchych (DVPE) (z obliczeń) PN-EN 13016-1:2024-11 Paliwa ciekle: benzyna bezolowiowa Rownowaznik preznosci par suchych (DVPE) (z obliczen) PN-EN 13016-1:2024-11","categories":["petro"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Dry vapour pressure equivalent (DVPE) (calculated)","search_en":"Liquid fuels: unleaded petrol Dry vapour pressure equivalent (DVPE) (calculated) Fuels Laboratory Gdynia PN-EN 13016-1:2024-11","test_object_en":"Liquid fuels: unleaded petrol","lab_section_zh":"燃料实验室 Gdynia","search_zh":"液体燃料：无铅汽油 干蒸气压当量（DVPE）（由计算得出） 燃料实验室 Gdynia PN-EN 13016-1:2024-11","test_object_zh":"液体燃料：无铅汽油","methodology_zh":"干蒸气压当量（DVPE）（由计算得出）"},{"_id":"6a7d76396040ebab2620d284","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Zawartość benzenu","parameters":[{"name":"Zakres","range":"(0,1 – 2,0) % (v/v)"}],"technique":"Metoda spektrometrii w zakresie podczerwieni (IR)","techniques":["Metoda spektrometrii w zakresie podczerwieni (IR)"],"computed":[],"activity":"Zawartość benzenu\nZakres (0,1 – 2,0) % (v/v)\nMetoda spektrometrii w zakresie podczerwieni (IR)","reference":"PN-EN 238:2000+A1:2008","norm_bases":["PN-EN 238:2000+A1:2008"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Zawartość benzenu\nZakres (0,1 – 2,0) % (v/v)\nMetoda spektrometrii w zakresie podczerwieni (IR) PN-EN 238:2000+A1:2008 Paliwa ciekle: benzyna bezolowiowa Zawartosc benzenu\nZakres (0,1 – 2,0) % (v/v)\nMetoda spektrometrii w zakresie podczerwieni (IR) PN-EN 238:2000+A1:2008","categories":["petro"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Benzene content","parameters_en":[{"name":"Range","range":"(0,1 – 2,0) % (v/v)"}],"search_en":"Liquid fuels: unleaded petrol Benzene content Spectrometry method in the infrared range (IR) Fuels Laboratory Gdynia Range PN-EN 238:2000+A1:2008","technique_en":"Spectrometry method in the infrared range (IR)","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"范围","range":"(0,1 – 2,0) % (v/v)"}],"search_zh":"液体燃料：无铅汽油 苯含量 红外光谱法（IR） 燃料实验室 Gdynia 范围 PN-EN 238:2000+A1:2008","lab_section_zh":"燃料实验室 Gdynia","technique_zh":"红外光谱法（IR）","test_object_zh":"液体燃料：无铅汽油","methodology_zh":"苯含量"},{"_id":"6a7d76396040ebab2620d285","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Zawartość grup węglowodorów","parameters":[{"name":"węglowodory aromatyczne"},{"name":"Zakres","range":"(20,0 – 40,0) % (v/v)"},{"name":"węglowodory olefinowe","range":"(1,0 – 20,0) % (v/v)"},{"name":"węglowodory nasycone","range":"(45,0 – 68,0) % (v/v)"}],"technique":"Metoda chromatografii żelowej (FIA)","techniques":["Metoda chromatografii żelowej (FIA)"],"computed":[],"activity":"Zawartość grup węglowodorów\nZakres:\nwęglowodory aromatyczne\nZakres (20,0 – 40,0) % (v/v)\nwęglowodory olefinowe (1,0 – 20,0) % (v/v)\nwęglowodory nasycone (45,0 – 68,0) % (v/v)\nMetoda chromatografii żelowej (FIA)","reference":"PN-EN 15553+A1:2025-05","norm_bases":["PN-EN 15553+A1:2025-05"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Zawartość grup węglowodorów\nZakres:\nwęglowodory aromatyczne\nZakres (20,0 – 40,0) % (v/v)\nwęglowodory olefinowe (1,0 – 20,0) % (v/v)\nwęglowodory nasycone (45,0 – 68,0) % (v/v)\nMetoda chromatografii żelowej (FIA) PN-EN 15553+A1:2025-05 Paliwa ciekle: benzyna bezolowiowa Zawartosc grup weglowodorow\nZakres:\nweglowodory aromatyczne\nZakres (20,0 – 40,0) % (v/v)\nweglowodory olefinowe (1,0 – 20,0) % (v/v)\nweglowodory nasycone (45,0 – 68,0) % (v/v)\nMetoda chromatografii zelowej (FIA) PN-EN 15553+A1:2025-05","categories":["petro"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Hydrocarbon group content","parameters_en":[{"name":"aromatic hydrocarbons"},{"name":"Range","range":"(20,0 – 40,0) % (v/v)"},{"name":"olefinic hydrocarbons","range":"(1,0 – 20,0) % (v/v)"},{"name":"saturated hydrocarbons","range":"(45,0 – 68,0) % (v/v)"}],"search_en":"Liquid fuels: unleaded petrol Hydrocarbon group content Gel chromatography method (FIA) Fuels Laboratory Gdynia aromatic hydrocarbons Range olefinic hydrocarbons saturated hydrocarbons PN-EN 15553+A1:2025-05","technique_en":"Gel chromatography method (FIA)","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"芳香烃"},{"name":"范围","range":"(20,0 – 40,0) % (v/v)"},{"name":"烯烃","range":"(1,0 – 20,0) % (v/v)"},{"name":"饱和烃","range":"(45,0 – 68,0) % (v/v)"}],"search_zh":"液体燃料：无铅汽油 烃族组成含量 凝胶色谱法（FIA） 燃料实验室 Gdynia 芳香烃 范围 烯烃 饱和烃 PN-EN 15553+A1:2025-05","lab_section_zh":"燃料实验室 Gdynia","test_object_zh":"液体燃料：无铅汽油","methodology_zh":"烃族组成含量","technique_zh":"凝胶色谱法（FIA）"},{"_id":"6a7d76396040ebab2620d286","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)","parameters":[{"name":"Zakres","range":"(0,05 – 10,0) % (v/v)"}],"technique":"Metoda spektrometrii w zakresie podczerwieni (IR)","techniques":["Metoda spektrometrii w zakresie podczerwieni (IR)"],"computed":[],"activity":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres (0,05 – 10,0) % (v/v)\nMetoda spektrometrii w zakresie podczerwieni (IR)","reference":"PN-EN 14078:2014-06","norm_bases":["PN-EN 14078:2014-06"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres (0,05 – 10,0) % (v/v)\nMetoda spektrometrii w zakresie podczerwieni (IR) PN-EN 14078:2014-06 Paliwa ciekle: olej napedowy Zawartosc estrow metylowych kwasow tluszczowych (FAME)\nZakres (0,05 – 10,0) % (v/v)\nMetoda spektrometrii w zakresie podczerwieni (IR) PN-EN 14078:2014-06","categories":["petro"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Fatty acid methyl esters (FAME) content","parameters_en":[{"name":"Range","range":"(0,05 – 10,0) % (v/v)"}],"search_en":"Liquid fuels: diesel fuel Fatty acid methyl esters (FAME) content Spectrometry method in the infrared range (IR) Fuels Laboratory Gdynia Range PN-EN 14078:2014-06","technique_en":"Spectrometry method in the infrared range (IR)","test_object_en":"Liquid fuels: diesel fuel","parameters_zh":[{"name":"范围","range":"(0,05 – 10,0) % (v/v)"}],"search_zh":"液体燃料：柴油 脂肪酸甲酯（FAME）含量 红外光谱法（IR） 燃料实验室 Gdynia 范围 PN-EN 14078:2014-06","lab_section_zh":"燃料实验室 Gdynia","test_object_zh":"液体燃料：柴油","technique_zh":"红外光谱法（IR）","methodology_zh":"脂肪酸甲酯（FAME）含量"},{"_id":"6a7d76396040ebab2620d287","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki, paliwo żeglugowe","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(3,0 – 60,0) mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Zawartość siarki\nZakres (3,0 – 60,0) mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"PN-EN ISO 20846:2020-03","norm_bases":["PN-EN ISO 20846:2020-03"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki, paliwo żeglugowe Zawartość siarki\nZakres (3,0 – 60,0) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, olej opalowy lekki, paliwo zeglugowe Zawartosc siarki\nZakres (3,0 – 60,0) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03","categories":["petro"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(3,0 – 60,0) mg/kg"}],"search_en":"Liquid fuels: diesel fuel, unleaded petrol, light fuel oil, marine fuel Sulfur content Ultraviolet fluorescence method Fuels Laboratory Gdynia Range PN-EN ISO 20846:2020-03","technique_en":"Ultraviolet fluorescence method","test_object_en":"Liquid fuels: diesel fuel, unleaded petrol, light fuel oil, marine fuel","parameters_zh":[{"name":"范围","range":"(3,0 – 60,0) mg/kg"}],"search_zh":"液体燃料：柴油、无铅汽油、轻质燃料油、船用燃料 硫含量 紫外荧光法 燃料实验室 Gdynia 范围 PN-EN ISO 20846:2020-03","lab_section_zh":"燃料实验室 Gdynia","methodology_zh":"硫含量","technique_zh":"紫外荧光法","test_object_zh":"液体燃料：柴油、无铅汽油、轻质燃料油、船用燃料"},{"_id":"6a7d76396040ebab2620d288","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, paliwo żeglugowe","methodology":"Temperatura zapłonu","parameters":[{"name":"Zakres","range":"(40,0 – 140,0) °C"},{"name":"Pensky’ego-Martensa"}],"technique":"Metoda zamkniętego tygla","techniques":["Metoda zamkniętego tygla"],"computed":[],"activity":"Temperatura zapłonu\nZakres:\nZakres (40,0 – 140,0) °C\nPensky’ego-Martensa\nMetoda zamkniętego tygla","reference":"PN-EN ISO 2719:2016-08 +A1:2021-06","norm_bases":["PN-EN ISO 2719:2016-08 +A1:2021-06"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, paliwo żeglugowe Temperatura zapłonu\nZakres:\nZakres (40,0 – 140,0) °C\nPensky’ego-Martensa\nMetoda zamkniętego tygla PN-EN ISO 2719:2016-08 +A1:2021-06 Paliwa ciekle: olej napedowy, olej opalowy lekki, olej opalowy ciezki, paliwo zeglugowe Temperatura zaplonu\nZakres:\nZakres (40,0 – 140,0) °C\nPensky’ego-Martensa\nMetoda zamknietego tygla PN-EN ISO 2719:2016-08 +A1:2021-06","categories":["petro"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Flash point","parameters_en":[{"name":"Range","range":"(40,0 – 140,0) °C"},{"name":"Pensky-Martens"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil, heavy fuel oil, marine fuel Flash point Closed cup method Fuels Laboratory Gdynia Range Pensky-Martens PN-EN ISO 2719:2016-08 +A1:2021-06","technique_en":"Closed cup method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil, heavy fuel oil, marine fuel","parameters_zh":[{"name":"范围","range":"(40,0 – 140,0) °C"},{"name":"宾斯基-马丁"}],"search_zh":"液体燃料：柴油、轻质燃料油、重燃料油、船用燃料 闪点 闭口杯法 燃料实验室 Gdynia 范围 宾斯基-马丁 PN-EN ISO 2719:2016-08 +A1:2021-06","lab_section_zh":"燃料实验室 Gdynia","methodology_zh":"闪点","technique_zh":"闭口杯法","test_object_zh":"液体燃料：柴油、轻质燃料油、重燃料油、船用燃料"},{"_id":"6a7d76396040ebab2620d289","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: oleje napędowe, oleje opałowe lekkie","methodology":"Temperatura zablokowania zimnego filtru","parameters":[{"name":"Zakres","range":"(-41 – 0) °C"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura zablokowania zimnego filtru\nZakres (-41 – 0) °C\nMetoda optyczna","reference":"PN-EN 116:2015-09","norm_bases":["PN-EN 116:2015-09"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: oleje napędowe, oleje opałowe lekkie Temperatura zablokowania zimnego filtru\nZakres (-41 – 0) °C\nMetoda optyczna PN-EN 116:2015-09 Paliwa ciekle: oleje napedowe, oleje opalowe lekkie Temperatura zablokowania zimnego filtru\nZakres (-41 – 0) °C\nMetoda optyczna PN-EN 116:2015-09","categories":["petro"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Cold filter plugging point","parameters_en":[{"name":"Range","range":"(-41 – 0) °C"}],"search_en":"Liquid fuels: diesel fuels, light heating oils Cold filter plugging point Optical method Fuels Laboratory Gdynia Range PN-EN 116:2015-09","technique_en":"Optical method","test_object_en":"Liquid fuels: diesel fuels, light heating oils","parameters_zh":[{"name":"范围","range":"(-41 – 0) °C"}],"search_zh":"冷滤点 光学法 燃料实验室 Gdynia 范围 PN-EN 116:2015-09","technique_zh":"光学法","lab_section_zh":"燃料实验室 Gdynia","methodology_zh":"冷滤点"},{"_id":"6a7d76396040ebab2620d28a","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: oleje napędowe, estry metylowe kwasów tłuszczowych (FAME)","methodology":"Stabilność oksydacyjna","parameters":[{"name":"Zakres","range":"(1,0 – 40,0) h"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Stabilność oksydacyjna\nZakres (1,0 – 40,0) h\nMetoda konduktometryczna","reference":"PN-EN 15751:2025-10","norm_bases":["PN-EN 15751:2025-10"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: oleje napędowe, estry metylowe kwasów tłuszczowych (FAME) Stabilność oksydacyjna\nZakres (1,0 – 40,0) h\nMetoda konduktometryczna PN-EN 15751:2025-10 Paliwa ciekle: oleje napedowe, estry metylowe kwasow tluszczowych (FAME) Stabilnosc oksydacyjna\nZakres (1,0 – 40,0) h\nMetoda konduktometryczna PN-EN 15751:2025-10","categories":["petro"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Oxidation stability","parameters_en":[{"name":"Range","range":"(1,0 – 40,0) h"}],"search_en":"Liquid fuels: diesel fuels, fatty acid methyl esters (FAME) Oxidation stability Conductometric method Fuels Laboratory Gdynia Range PN-EN 15751:2025-10","technique_en":"Conductometric method","test_object_en":"Liquid fuels: diesel fuels, fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(1,0 – 40,0) h"}],"search_zh":"氧化安定性 电导法 燃料实验室 Gdynia 范围 PN-EN 15751:2025-10","technique_zh":"电导法","lab_section_zh":"燃料实验室 Gdynia","methodology_zh":"氧化安定性"},{"_id":"6a7d76396040ebab2620d28b","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, paliwo żeglugowe","methodology":"Pozostałość po koksowaniu","parameters":[{"name":"Zakres","range":"(0,01 – 15,00) % (m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Pozostałość po koksowaniu\nZakres (0,01 – 15,00) % (m/m)\nMetoda wagowa","reference":"PN-EN ISO 10370:2014-12","norm_bases":["PN-EN ISO 10370:2014-12"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, paliwo żeglugowe Pozostałość po koksowaniu\nZakres (0,01 – 15,00) % (m/m)\nMetoda wagowa PN-EN ISO 10370:2014-12 Paliwa ciekle: olej napedowy, olej opalowy lekki, paliwo zeglugowe Pozostalosc po koksowaniu\nZakres (0,01 – 15,00) % (m/m)\nMetoda wagowa PN-EN ISO 10370:2014-12","categories":["petro"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Carbon residue","parameters_en":[{"name":"Range","range":"(0,01 – 15,00) % (m/m)"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil, marine fuel Carbon residue Gravimetric method Fuels Laboratory Gdynia Range PN-EN ISO 10370:2014-12","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil, marine fuel","parameters_zh":[{"name":"范围","range":"(0,01 – 15,00) % (m/m)"}],"search_zh":"液体燃料：柴油、轻质燃料油、船用燃料 残炭 重量法 燃料实验室 Gdynia 范围 PN-EN ISO 10370:2014-12","technique_zh":"重量法","lab_section_zh":"燃料实验室 Gdynia","methodology_zh":"残炭","test_object_zh":"液体燃料：柴油、轻质燃料油、船用燃料"},{"_id":"6a7d76396040ebab2620d28c","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, paliwo żeglugowe","methodology":"Stabilność oksydacyjna","parameters":[{"name":"Zakres","range":"(2 – 25) g/m3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stabilność oksydacyjna\nZakres (2 – 25) g/m3\nMetoda wagowa","reference":"PN-EN ISO 12205:2011 +Ap1:2013-09","norm_bases":["PN-EN ISO 12205:2011 +Ap1:2013-09"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, paliwo żeglugowe Stabilność oksydacyjna\nZakres (2 – 25) g/m3\nMetoda wagowa PN-EN ISO 12205:2011 +Ap1:2013-09 Paliwa ciekle: olej napedowy, olej opalowy lekki, paliwo zeglugowe Stabilnosc oksydacyjna\nZakres (2 – 25) g/m3\nMetoda wagowa PN-EN ISO 12205:2011 +Ap1:2013-09","categories":["petro"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Oxidation stability","parameters_en":[{"name":"Range","range":"(2 – 25) g/m3"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil, marine fuel Oxidation stability Gravimetric method Fuels Laboratory Gdynia Range PN-EN ISO 12205:2011 +Ap1:2013-09","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil, marine fuel","parameters_zh":[{"name":"范围","range":"(2 – 25) g/m3"}],"search_zh":"液体燃料：柴油、轻质燃料油、船用燃料 氧化安定性 重量法 燃料实验室 Gdynia 范围 PN-EN ISO 12205:2011 +Ap1:2013-09","technique_zh":"重量法","lab_section_zh":"燃料实验室 Gdynia","methodology_zh":"氧化安定性","test_object_zh":"液体燃料：柴油、轻质燃料油、船用燃料"},{"_id":"6a7d76396040ebab2620d28d","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(30000 – 45000) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres:\nZakres (30000 – 45000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-C-04062:2018-05","norm_bases":["PN-C-04062:2018-05"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki Ciepło spalania\nZakres:\nZakres (30000 – 45000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-C-04062:2018-05 Paliwa ciekle: olej napedowy, olej opalowy lekki, olej opalowy ciezki Cieplo spalania\nZakres:\nZakres (30000 – 45000) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-C-04062:2018-05","categories":["petro"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(30000 – 45000) kJ/kg"},{"name":"Net calorific value (calculated)"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil, heavy fuel oil Gross calorific value Calorimetric method Fuels Laboratory Gdynia Range Net calorific value (calculated) PN-C-04062:2018-05","technique_en":"Calorimetric method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil, heavy fuel oil","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(30000 – 45000) kJ/kg"},{"name":"低位发热量（计算值）"}],"search_zh":"高位发热量 量热法 燃料实验室 Gdynia 范围 低位发热量（计算值） PN-C-04062:2018-05","technique_zh":"量热法","lab_section_zh":"燃料实验室 Gdynia"},{"_id":"6a7d76396040ebab2620d28e","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy ciężki","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,05 – 25) % (m/m)"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Zawartość wody\nZakres (0,05 – 25) % (m/m)\nMetoda destylacyjna","reference":"PN-EN ISO 9029:2005","norm_bases":["PN-EN ISO 9029:2005"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy ciężki Zawartość wody\nZakres (0,05 – 25) % (m/m)\nMetoda destylacyjna PN-EN ISO 9029:2005 Paliwa ciekle: olej opalowy ciezki Zawartosc wody\nZakres (0,05 – 25) % (m/m)\nMetoda destylacyjna PN-EN ISO 9029:2005","categories":["petro","water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(0,05 – 25) % (m/m)"}],"search_en":"Liquid fuels: heavy fuel oil Water content Distillation method Fuels Laboratory Gdynia Range PN-EN ISO 9029:2005","technique_en":"Distillation method","test_object_en":"Liquid fuels: heavy fuel oil","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,05 – 25) % (m/m)"}],"search_zh":"液体燃料：重燃料油 水分含量 蒸馏法 燃料实验室 Gdynia 范围 PN-EN ISO 9029:2005","lab_section_zh":"燃料实验室 Gdynia","technique_zh":"蒸馏法","test_object_zh":"液体燃料：重燃料油"},{"_id":"6a7d76396040ebab2620d28f","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki, paliwo żeglugowe","methodology":"Skład frakcyjny","parameters":[{"name":"Zakres","range":"(10,0 – 400,0) °C"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny\nZakres (10,0 – 400,0) °C\nMetoda destylacyjna","reference":"PN-EN ISO 3405:2019-05","norm_bases":["PN-EN ISO 3405:2019-05"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki, paliwo żeglugowe Skład frakcyjny\nZakres (10,0 – 400,0) °C\nMetoda destylacyjna PN-EN ISO 3405:2019-05 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, olej opalowy lekki, paliwo zeglugowe Sklad frakcyjny\nZakres (10,0 – 400,0) °C\nMetoda destylacyjna PN-EN ISO 3405:2019-05","categories":["petro"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Fractional composition","parameters_en":[{"name":"Range","range":"(10,0 – 400,0) °C"}],"search_en":"Liquid fuels: diesel fuel, unleaded petrol, light fuel oil, marine fuel Fractional composition Distillation method Fuels Laboratory Gdynia Range PN-EN ISO 3405:2019-05","technique_en":"Distillation method","test_object_en":"Liquid fuels: diesel fuel, unleaded petrol, light fuel oil, marine fuel","parameters_zh":[{"name":"范围","range":"(10,0 – 400,0) °C"}],"search_zh":"液体燃料：柴油、无铅汽油、轻质燃料油、船用燃料 馏程组成 蒸馏法 燃料实验室 Gdynia 范围 PN-EN ISO 3405:2019-05","lab_section_zh":"燃料实验室 Gdynia","technique_zh":"蒸馏法","methodology_zh":"馏程组成","test_object_zh":"液体燃料：柴油、无铅汽油、轻质燃料油、船用燃料"},{"_id":"6a7d76396040ebab2620d290","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki, paliwo żeglugowe","methodology":"Gęstość w temperaturze 15°C, 20°C","parameters":[{"name":"Zakres","range":"(720,0 – 900,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 15°C, 20°C\nZakres (720,0 – 900,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki, paliwo żeglugowe Gęstość w temperaturze 15°C, 20°C\nZakres (720,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, olej opalowy lekki, paliwo zeglugowe Gestosc w temperaturze 15°C, 20°C\nZakres (720,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Density at 15°C, 20°C","parameters_en":[{"name":"Range","range":"(720,0 – 900,0) kg/m3"}],"search_en":"Liquid fuels: diesel fuel, unleaded petrol, light fuel oil, marine fuel Density at 15°C, 20°C Oscillation method Fuels Laboratory Gdynia Range PN-EN ISO 12185:2024-08","technique_en":"Oscillation method","test_object_en":"Liquid fuels: diesel fuel, unleaded petrol, light fuel oil, marine fuel","parameters_zh":[{"name":"范围","range":"(720,0 – 900,0) kg/m3"}],"search_zh":"液体燃料：柴油、无铅汽油、轻质燃料油、船用燃料 15°C、20°C 时的密度 振荡法 燃料实验室 Gdynia 范围 PN-EN ISO 12185:2024-08","technique_zh":"振荡法","lab_section_zh":"燃料实验室 Gdynia","methodology_zh":"15°C、20°C 时的密度","test_object_zh":"液体燃料：柴油、无铅汽油、轻质燃料油、船用燃料"},{"_id":"6a7d76396040ebab2620d291","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy ciężki","methodology":"Gęstość w temperaturze 15°C","parameters":[{"name":"Zakres","range":"(890,0 – 990) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 15°C\nZakres (890,0 – 990) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy ciężki Gęstość w temperaturze 15°C\nZakres (890,0 – 990) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: olej opalowy ciezki Gestosc w temperaturze 15°C\nZakres (890,0 – 990) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Density at 15°C","parameters_en":[{"name":"Range","range":"(890,0 – 990) kg/m3"}],"search_en":"Liquid fuels: heavy fuel oil Density at 15°C Oscillation method Fuels Laboratory Gdynia Range PN-EN ISO 12185:2024-08","technique_en":"Oscillation method","test_object_en":"Liquid fuels: heavy fuel oil","parameters_zh":[{"name":"范围","range":"(890,0 – 990) kg/m3"}],"search_zh":"液体燃料：重燃料油 15°C 时的密度 振荡法 燃料实验室 Gdynia 范围 PN-EN ISO 12185:2024-08","technique_zh":"振荡法","lab_section_zh":"燃料实验室 Gdynia","methodology_zh":"15°C 时的密度","test_object_zh":"液体燃料：重燃料油"},{"_id":"6a7d76396040ebab2620d292","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Obecność siarkowodoru","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Obecność siarkowodoru\nMetoda wizualna","reference":"PN-EN ISO 8819:2000","norm_bases":["PN-EN ISO 8819:2000"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Obecność siarkowodoru\nMetoda wizualna PN-EN ISO 8819:2000 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Obecnosc siarkowodoru\nMetoda wizualna PN-EN ISO 8819:2000","categories":["petro"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Presence of hydrogen sulfide","search_en":"Gaseous fuels: liquefied petroleum gases, LPG Presence of hydrogen sulfide Visual method Fuels Laboratory Gdynia PN-EN ISO 8819:2000","technique_en":"Visual method","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","search_zh":"气体燃料：液化石油气（LPG） 硫化氢的检出 目视法 燃料实验室 Gdynia PN-EN ISO 8819:2000","technique_zh":"目视法","lab_section_zh":"燃料实验室 Gdynia","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"硫化氢的检出"},{"_id":"6a7d76396040ebab2620d293","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(1,0 – 196) mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Zawartość siarki\nZakres (1,0 – 196) mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"ASTM D 6667-21","norm_bases":["ASTM D 6667-21"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Zawartość siarki\nZakres (1,0 – 196) mg/kg\nMetoda fluorescencji w nadfiolecie ASTM D 6667-21 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Zawartosc siarki\nZakres (1,0 – 196) mg/kg\nMetoda fluorescencji w nadfiolecie ASTM D 6667-21","categories":["petro"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(1,0 – 196) mg/kg"}],"search_en":"Gaseous fuels: liquefied petroleum gases, LPG Sulfur content Ultraviolet fluorescence method Fuels Laboratory Gdynia Range ASTM D 6667-21","technique_en":"Ultraviolet fluorescence method","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","parameters_zh":[{"name":"范围","range":"(1,0 – 196) mg/kg"}],"search_zh":"气体燃料：液化石油气（LPG） 硫含量 紫外荧光法 燃料实验室 Gdynia 范围 ASTM D 6667-21","lab_section_zh":"燃料实验室 Gdynia","methodology_zh":"硫含量","test_object_zh":"气体燃料：液化石油气（LPG）","technique_zh":"紫外荧光法"},{"_id":"6a7d76396040ebab2620d294","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Korodujące działanie na miedź","parameters":[{"name":"klasa korozji","range":"(1 – 4)"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Korodujące działanie na miedź\nklasa korozji (1 – 4)\nMetoda wizualna","reference":"PN-EN ISO 6251:2001","norm_bases":["PN-EN ISO 6251:2001"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Korodujące działanie na miedź\nklasa korozji (1 – 4)\nMetoda wizualna PN-EN ISO 6251:2001 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Korodujace dzialanie na miedz\nklasa korozji (1 – 4)\nMetoda wizualna PN-EN ISO 6251:2001","categories":["petro","materials"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Copper strip corrosion","parameters_en":[{"name":"corrosion class","range":"(1 – 4)"}],"search_en":"Gaseous fuels: liquefied petroleum gases, LPG Copper strip corrosion Visual method Fuels Laboratory Gdynia corrosion class PN-EN ISO 6251:2001","technique_en":"Visual method","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","search_zh":"气体燃料：液化石油气（LPG） 铜片腐蚀 目视法 燃料实验室 Gdynia 腐蚀等级 PN-EN ISO 6251:2001","technique_zh":"目视法","lab_section_zh":"燃料实验室 Gdynia","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"铜片腐蚀","parameters_zh":[{"name":"腐蚀等级","range":"(1 – 4)"}]},{"_id":"6a7d76396040ebab2620d295","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Obecność wody","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Obecność wody\nMetoda wizualna","reference":"PN-EN 15469:2009 | PN-C-96008:1998 p. 4.4.5","norm_bases":["PN-EN 15469:2009","PN-C-96008:1998 p. 4.4.5"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Obecność wody\nMetoda wizualna PN-EN 15469:2009 | PN-C-96008:1998 p. 4.4.5 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Obecnosc wody\nMetoda wizualna PN-EN 15469:2009 | PN-C-96008:1998 p. 4.4.5","categories":["petro","water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Presence of water","search_en":"Gaseous fuels: liquefied petroleum gases, LPG Presence of water Visual method Fuels Laboratory Gdynia PN-EN 15469:2009 | PN-C-96008:1998 p. 4.4.5","technique_en":"Visual method","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","search_zh":"气体燃料：液化石油气（LPG） 水的检出 目视法 燃料实验室 Gdynia PN-EN 15469:2009 | PN-C-96008:1998 p. 4.4.5","technique_zh":"目视法","lab_section_zh":"燃料实验室 Gdynia","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"水的检出"},{"_id":"6a7d76396040ebab2620d296","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Wartość opałowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość opałowa (z obliczeń)","reference":"PN-C-96008:1998 p. 4.4.8","norm_bases":["PN-C-96008:1998 p. 4.4.8"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Wartość opałowa (z obliczeń) PN-C-96008:1998 p. 4.4.8 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Wartosc opalowa (z obliczen) PN-C-96008:1998 p. 4.4.8","categories":["petro"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Net calorific value (calculated)","search_en":"Gaseous fuels: liquefied petroleum gases, LPG Net calorific value (calculated) Fuels Laboratory Gdynia PN-C-96008:1998 p. 4.4.8","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","methodology_zh":"低位发热量（计算值）","search_zh":"气体燃料：液化石油气（LPG） 低位发热量（计算值） 燃料实验室 Gdynia PN-C-96008:1998 p. 4.4.8","lab_section_zh":"燃料实验室 Gdynia","test_object_zh":"气体燃料：液化石油气（LPG）"},{"_id":"6a7d76396040ebab2620d297","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Skład węglowodorowy","parameters":[{"name":"Zakres","range":"(0,1 – 100) % (m/m)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Skład węglowodorowy\nZakres (0,1 – 100) % (m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 27941:2015-12","norm_bases":["PN-EN 27941:2015-12"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Skład węglowodorowy\nZakres (0,1 – 100) % (m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 27941:2015-12 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Sklad weglowodorowy\nZakres (0,1 – 100) % (m/m)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 27941:2015-12","categories":["petro"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Hydrocarbon composition","parameters_en":[{"name":"Range","range":"(0,1 – 100) % (m/m)"}],"search_en":"Gaseous fuels: liquefied petroleum gases, LPG Hydrocarbon composition Gas chromatography with flame ionization detection (GC-FID) Fuels Laboratory Gdynia Range PN-EN 27941:2015-12","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","parameters_zh":[{"name":"范围","range":"(0,1 – 100) % (m/m)"}],"search_zh":"气体燃料：液化石油气（LPG） 烃类组成 气相色谱-氢火焰离子化检测法（GC-FID） 燃料实验室 Gdynia 范围 PN-EN 27941:2015-12","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"燃料实验室 Gdynia","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"烃类组成"},{"_id":"6a7d76396040ebab2620d298","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Całkowita zawartość dienów","parameters":[{"name":"Zakres","range":"(0,1 – 1,0) % (mol/mol)"},{"name":"Zakres","range":"(0,1 – 1,0) % (m/m)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Całkowita zawartość dienów\nZakres:\nZakres (0,1 – 1,0) % (mol/mol)\nZakres (0,1 – 1,0) % (m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 27941:2015-12","norm_bases":["PN-EN 27941:2015-12"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Całkowita zawartość dienów\nZakres:\nZakres (0,1 – 1,0) % (mol/mol)\nZakres (0,1 – 1,0) % (m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 27941:2015-12 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Calkowita zawartosc dienow\nZakres:\nZakres (0,1 – 1,0) % (mol/mol)\nZakres (0,1 – 1,0) % (m/m)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 27941:2015-12","categories":["petro"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Total diene content","parameters_en":[{"name":"Range","range":"(0,1 – 1,0) % (mol/mol)"},{"name":"Range","range":"(0,1 – 1,0) % (m/m)"}],"search_en":"Gaseous fuels: liquefied petroleum gases, LPG Total diene content Gas chromatography with flame ionization detection (GC-FID) Fuels Laboratory Gdynia Range Range PN-EN 27941:2015-12","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","parameters_zh":[{"name":"范围","range":"(0,1 – 1,0) % (mol/mol)"},{"name":"范围","range":"(0,1 – 1,0) % (m/m)"}],"search_zh":"气体燃料：液化石油气（LPG） 二烯烃总含量 气相色谱-氢火焰离子化检测法（GC-FID） 燃料实验室 Gdynia 范围 范围 PN-EN 27941:2015-12","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"燃料实验室 Gdynia","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"二烯烃总含量"},{"_id":"6a7d76396040ebab2620d299","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Liczba oktanowa motorowa MON (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Liczba oktanowa motorowa MON (z obliczeń)","reference":"PN-EN 589:2024-08 zał. B","norm_bases":["PN-EN 589:2024-08 zał. B"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Liczba oktanowa motorowa MON (z obliczeń) PN-EN 589:2024-08 zał. B Paliwa gazowe: skroplone gazy weglowodorowe, LPG Liczba oktanowa motorowa MON (z obliczen) PN-EN 589:2024-08 zal. B","categories":["petro"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Motor octane number MON (calculated)","search_en":"Gaseous fuels: liquefied petroleum gases, LPG Motor octane number MON (calculated) Fuels Laboratory Gdynia PN-EN 589:2024-08 zał. B","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","lab_section_zh":"燃料实验室 Gdynia","search_zh":"气体燃料：液化石油气（LPG） 马达法辛烷值 MON（由计算得出） 燃料实验室 Gdynia PN-EN 589:2024-08 zał. B","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"马达法辛烷值 MON（由计算得出）"},{"_id":"6a7d76396040ebab2620d29a","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Gęstość w temperaturze 15 °C (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość w temperaturze 15 °C (z obliczeń)","reference":"PN-EN ISO 8973:2000+A1:2020-10","norm_bases":["PN-EN ISO 8973:2000+A1:2020-10"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Gęstość w temperaturze 15 °C (z obliczeń) PN-EN ISO 8973:2000+A1:2020-10 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Gestosc w temperaturze 15 °C (z obliczen) PN-EN ISO 8973:2000+A1:2020-10","categories":["petro"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Density at a temperature of 15 °C (calculated)","search_en":"Gaseous fuels: liquefied petroleum gases, LPG Density at a temperature of 15 °C (calculated) Fuels Laboratory Gdynia PN-EN ISO 8973:2000+A1:2020-10","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","lab_section_zh":"燃料实验室 Gdynia","search_zh":"气体燃料：液化石油气（LPG） 燃料实验室 Gdynia PN-EN ISO 8973:2000+A1:2020-10","test_object_zh":"气体燃料：液化石油气（LPG）"},{"_id":"6a7d76396040ebab2620d29b","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Gęstość w temperaturze 15,6 °C (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość w temperaturze 15,6 °C (z obliczeń)","reference":"PN-C-96008:1998 p. 4.4.9","norm_bases":["PN-C-96008:1998 p. 4.4.9"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Gęstość w temperaturze 15,6 °C (z obliczeń) PN-C-96008:1998 p. 4.4.9 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Gestosc w temperaturze 15,6 °C (z obliczen) PN-C-96008:1998 p. 4.4.9","categories":["petro"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Density at a temperature of 15,6 °C (calculated)","search_en":"Gaseous fuels: liquefied petroleum gases, LPG Density at a temperature of 15,6 °C (calculated) Fuels Laboratory Gdynia PN-C-96008:1998 p. 4.4.9","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","lab_section_zh":"燃料实验室 Gdynia","search_zh":"气体燃料：液化石油气（LPG） 燃料实验室 Gdynia PN-C-96008:1998 p. 4.4.9","test_object_zh":"气体燃料：液化石油气（LPG）"},{"_id":"6a7d76396040ebab2620d29c","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Prężność par w temperaturach: -15 °C, 40 °C, 70 °C (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Prężność par w temperaturach: -15 °C, 40 °C, 70 °C (z obliczeń)","reference":"PN-C-96008:1998 p. 4.4.10","norm_bases":["PN-C-96008:1998 p. 4.4.10"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Prężność par w temperaturach: -15 °C, 40 °C, 70 °C (z obliczeń) PN-C-96008:1998 p. 4.4.10 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Preznosc par w temperaturach: -15 °C, 40 °C, 70 °C (z obliczen) PN-C-96008:1998 p. 4.4.10","categories":["petro"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Vapour pressure at temperatures: -15 °C, 40 °C, 70 °C (calculated)","search_en":"Gaseous fuels: liquefied petroleum gases, LPG Vapour pressure at temperatures: -15 °C, 40 °C, 70 °C (calculated) Fuels Laboratory Gdynia PN-C-96008:1998 p. 4.4.10","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","lab_section_zh":"燃料实验室 Gdynia","search_zh":"气体燃料：液化石油气（LPG） 燃料实验室 Gdynia PN-C-96008:1998 p. 4.4.10","test_object_zh":"气体燃料：液化石油气（LPG）"},{"_id":"6a7d76396040ebab2620d29d","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Prężność par, oszacowana w temperaturach: -10 °C, -5 °C, 0 °C, 10 °C, 20 °C, 37,8 °C, 40 °C, 50 °C, 70 °C (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Prężność par, oszacowana w temperaturach: -10 °C, -5 °C, 0 °C, 10 °C, 20 °C, 37,8 °C, 40 °C, 50 °C, 70 °C (z obliczeń)","reference":"PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2024-08 zał. C","norm_bases":["PN-EN ISO 8973:2000+A1:2020-10","PN-EN 589:2024-08 zał. C"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Prężność par, oszacowana w temperaturach: -10 °C, -5 °C, 0 °C, 10 °C, 20 °C, 37,8 °C, 40 °C, 50 °C, 70 °C (z obliczeń) PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2024-08 zał. C Paliwa gazowe: skroplone gazy weglowodorowe, LPG Preznosc par, oszacowana w temperaturach: -10 °C, -5 °C, 0 °C, 10 °C, 20 °C, 37,8 °C, 40 °C, 50 °C, 70 °C (z obliczen) PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2024-08 zal. C","categories":["petro"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Vapour pressure, estimated at temperatures: -10 °C, -5 °C, 0 °C, 10 °C, 20 °C, 37,8 °C, 40 °C, 50 °C, 70 °C (calculated)","search_en":"Gaseous fuels: liquefied petroleum gases, LPG Vapour pressure, estimated at temperatures: -10 °C, -5 °C, 0 °C, 10 °C, 20 °C, 37,8 °C, 40 °C, 50 °C, 70 °C (calculated) Fuels Laboratory Gdynia PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2024-08 zał. C","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","lab_section_zh":"燃料实验室 Gdynia","search_zh":"气体燃料：液化石油气（LPG） 燃料实验室 Gdynia PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2024-08 zał. C","test_object_zh":"气体燃料：液化石油气（LPG）"},{"_id":"6a7d76396040ebab2620d29e","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Temperatura, w której oszacowana względna prężność par jest nie mniejsza niż 150 kPa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura, w której oszacowana względna prężność par jest nie mniejsza niż 150 kPa (z obliczeń)","reference":"PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589+A1:2022-07 zał. C","norm_bases":["PN-EN ISO 8973:2000+A1:2020-10","PN-EN 589+A1:2022-07 zał. C"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Temperatura, w której oszacowana względna prężność par jest nie mniejsza niż 150 kPa (z obliczeń) PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589+A1:2022-07 zał. C Paliwa gazowe: skroplone gazy weglowodorowe, LPG Temperatura, w ktorej oszacowana wzgledna preznosc par jest nie mniejsza niz 150 kPa (z obliczen) PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589+A1:2022-07 zal. C","categories":["petro"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Temperature at which the estimated relative vapour pressure is not less than 150 kPa (calculated)","search_en":"Gaseous fuels: liquefied petroleum gases, LPG Temperature at which the estimated relative vapour pressure is not less than 150 kPa (calculated) Fuels Laboratory Gdynia PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589+A1:2022-07 zał. C","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","lab_section_zh":"燃料实验室 Gdynia","search_zh":"气体燃料：液化石油气（LPG） 估算相对蒸气压不低于 150 kPa 时的温度（由计算得出） 燃料实验室 Gdynia PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589+A1:2022-07 zał. C","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"估算相对蒸气压不低于 150 kPa 时的温度（由计算得出）"},{"_id":"6a7d76396040ebab2620d29f","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Zapach","parameters":[],"technique":"Metoda organoleptyczna","techniques":["Metoda organoleptyczna"],"computed":[],"activity":"Zapach\nMetoda organoleptyczna","reference":"PN-EN 589:2024-08 zał. A | PN-C-96008:1998 p. 4.4.7","norm_bases":["PN-EN 589:2024-08 zał. A","PN-C-96008:1998 p. 4.4.7"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Zapach\nMetoda organoleptyczna PN-EN 589:2024-08 zał. A | PN-C-96008:1998 p. 4.4.7 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Zapach\nMetoda organoleptyczna PN-EN 589:2024-08 zal. A | PN-C-96008:1998 p. 4.4.7","categories":["petro"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Odour","search_en":"Gaseous fuels: liquefied petroleum gases, LPG Odour Organoleptic method Fuels Laboratory Gdynia PN-EN 589:2024-08 zał. A | PN-C-96008:1998 p. 4.4.7","technique_en":"Organoleptic method","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","lab_section_zh":"燃料实验室 Gdynia","search_zh":"气体燃料：液化石油气（LPG） 气味 感官法 燃料实验室 Gdynia PN-EN 589:2024-08 zał. A | PN-C-96008:1998 p. 4.4.7","test_object_zh":"气体燃料：液化石油气（LPG）","technique_zh":"感官法","methodology_zh":"气味"},{"_id":"6a7d76396040ebab2620d2a0","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Zawartość oleju mineralnego","parameters":[{"name":"Zakres","range":"(0,0002 – 0,0100) % (m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość oleju mineralnego\nZakres (0,0002 – 0,0100) % (m/m)\nMetoda wagowa","reference":"PN-C-96008:1998 p. 4.4.4","norm_bases":["PN-C-96008:1998 p. 4.4.4"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Zawartość oleju mineralnego\nZakres (0,0002 – 0,0100) % (m/m)\nMetoda wagowa PN-C-96008:1998 p. 4.4.4 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Zawartosc oleju mineralnego\nZakres (0,0002 – 0,0100) % (m/m)\nMetoda wagowa PN-C-96008:1998 p. 4.4.4","categories":["petro"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Mineral oil content","parameters_en":[{"name":"Range","range":"(0,0002 – 0,0100) % (m/m)"}],"search_en":"Gaseous fuels: liquefied petroleum gases, LPG Mineral oil content Gravimetric method Fuels Laboratory Gdynia Range PN-C-96008:1998 p. 4.4.4","technique_en":"Gravimetric method","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","parameters_zh":[{"name":"范围","range":"(0,0002 – 0,0100) % (m/m)"}],"search_zh":"气体燃料：液化石油气（LPG） 矿物油含量 重量法 燃料实验室 Gdynia 范围 PN-C-96008:1998 p. 4.4.4","technique_zh":"重量法","lab_section_zh":"燃料实验室 Gdynia","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"矿物油含量"},{"_id":"6a7d76396040ebab2620d2a1","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Rozpuszczalna pozostałość","parameters":[{"name":"Zakres","range":"(20 – 100) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Rozpuszczalna pozostałość\nZakres (20 – 100) mg/kg\nMetoda wagowa","reference":"PN-EN 15471:2017-08","norm_bases":["PN-EN 15471:2017-08"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Rozpuszczalna pozostałość\nZakres (20 – 100) mg/kg\nMetoda wagowa PN-EN 15471:2017-08 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Rozpuszczalna pozostalosc\nZakres (20 – 100) mg/kg\nMetoda wagowa PN-EN 15471:2017-08","categories":["petro"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Soluble residue","parameters_en":[{"name":"Range","range":"(20 – 100) mg/kg"}],"search_en":"Gaseous fuels: liquefied petroleum gases, LPG Soluble residue Gravimetric method Fuels Laboratory Gdynia Range PN-EN 15471:2017-08","technique_en":"Gravimetric method","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","parameters_zh":[{"name":"范围","range":"(20 – 100) mg/kg"}],"search_zh":"气体燃料：液化石油气（LPG） 可溶性残余物 重量法 燃料实验室 Gdynia 范围 PN-EN 15471:2017-08","technique_zh":"重量法","lab_section_zh":"燃料实验室 Gdynia","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"可溶性残余物"},{"_id":"6a7d76396040ebab2620d2a2","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Skład węglowodorowy","parameters":[{"name":"Zakres","range":"(0,10 – 100,0) % (m/m)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Skład węglowodorowy\nZakres (0,10 – 100,0) % (m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"DIN 51619:2004-02","norm_bases":["DIN 51619:2004-02"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Skład węglowodorowy\nZakres (0,10 – 100,0) % (m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) DIN 51619:2004-02 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Sklad weglowodorowy\nZakres (0,10 – 100,0) % (m/m)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) DIN 51619:2004-02","categories":["petro"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Hydrocarbon composition","parameters_en":[{"name":"Range","range":"(0,10 – 100,0) % (m/m)"}],"search_en":"Gaseous fuels: liquefied petroleum gases, LPG Hydrocarbon composition Gas chromatography with flame ionization detection (GC-FID) Fuels Laboratory Gdynia Range DIN 51619:2004-02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","parameters_zh":[{"name":"范围","range":"(0,10 – 100,0) % (m/m)"}],"search_zh":"气体燃料：液化石油气（LPG） 烃类组成 气相色谱-氢火焰离子化检测法（GC-FID） 燃料实验室 Gdynia 范围 DIN 51619:2004-02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"燃料实验室 Gdynia","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"烃类组成"},{"_id":"6a7d76396040ebab2620d2a3","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Zawartość 1,3 butadienu","parameters":[{"name":"Zakres","range":"(0,01 – 1,00) % (m/m)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość 1,3 butadienu\nZakres (0,01 – 1,00) % (m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"DIN 51619:2004-02","norm_bases":["DIN 51619:2004-02"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Zawartość 1,3 butadienu\nZakres (0,01 – 1,00) % (m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) DIN 51619:2004-02 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Zawartosc 1,3 butadienu\nZakres (0,01 – 1,00) % (m/m)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) DIN 51619:2004-02","categories":["petro"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"1,3-butadiene content","parameters_en":[{"name":"Range","range":"(0,01 – 1,00) % (m/m)"}],"search_en":"Gaseous fuels: liquefied petroleum gases, LPG 1,3-butadiene content Gas chromatography with flame ionization detection (GC-FID) Fuels Laboratory Gdynia Range DIN 51619:2004-02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","parameters_zh":[{"name":"范围","range":"(0,01 – 1,00) % (m/m)"}],"search_zh":"气体燃料：液化石油气（LPG） 1,3-丁二烯含量 气相色谱-氢火焰离子化检测法（GC-FID） 燃料实验室 Gdynia 范围 DIN 51619:2004-02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"燃料实验室 Gdynia","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"1,3-丁二烯含量"},{"_id":"6a7d76396040ebab2620d2a4","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Całkowita zawartość dienów","parameters":[{"name":"Zakres","range":"(0,10 – 1,00) % (m/m)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Całkowita zawartość dienów\nZakres (0,10 – 1,00) % (m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"DIN 51619:2004-02","norm_bases":["DIN 51619:2004-02"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Całkowita zawartość dienów\nZakres (0,10 – 1,00) % (m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) DIN 51619:2004-02 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Calkowita zawartosc dienow\nZakres (0,10 – 1,00) % (m/m)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) DIN 51619:2004-02","categories":["petro"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Total diene content","parameters_en":[{"name":"Range","range":"(0,10 – 1,00) % (m/m)"}],"search_en":"Gaseous fuels: liquefied petroleum gases, LPG Total diene content Gas chromatography with flame ionization detection (GC-FID) Fuels Laboratory Gdynia Range DIN 51619:2004-02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","parameters_zh":[{"name":"范围","range":"(0,10 – 1,00) % (m/m)"}],"search_zh":"气体燃料：液化石油气（LPG） 二烯烃总含量 气相色谱-氢火焰离子化检测法（GC-FID） 燃料实验室 Gdynia 范围 DIN 51619:2004-02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"燃料实验室 Gdynia","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"二烯烃总含量"},{"_id":"6a7d76396040ebab2620d2a5","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Gęstość w temperaturze 15 °C, 20 °C","parameters":[{"name":"Zakres","range":"(860,0 – 900,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 15 °C, 20 °C\nZakres (860,0 – 900,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Gęstość w temperaturze 15 °C, 20 °C\nZakres (860,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Gestosc w temperaturze 15 °C, 20 °C\nZakres (860,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Density at a temperature of 15 °C, 20 °C","parameters_en":[{"name":"Range","range":"(860,0 – 900,0) kg/m3"}],"search_en":"Liquid fuels: fatty acid methyl esters (FAME) Density at a temperature of 15 °C, 20 °C Oscillation method Fuels Laboratory Gdynia Range PN-EN ISO 12185:2024-08","technique_en":"Oscillation method","test_object_en":"Liquid fuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(860,0 – 900,0) kg/m3"}],"search_zh":"液体燃料：脂肪酸甲酯（FAME） 振荡法 燃料实验室 Gdynia 范围 PN-EN ISO 12185:2024-08","technique_zh":"振荡法","lab_section_zh":"燃料实验室 Gdynia","test_object_zh":"液体燃料：脂肪酸甲酯（FAME）"},{"_id":"6a7d76396040ebab2620d2a6","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Lepkość kinematyczna w temp. 40 °C","parameters":[{"name":"Zakres","range":"(3,500 – 5,000) mm2/s"}],"technique":"Metoda kapilarna","techniques":["Metoda kapilarna"],"computed":[],"activity":"Lepkość kinematyczna w temp. 40 °C\nZakres (3,500 – 5,000) mm2/s\nMetoda kapilarna","reference":"PN-EN ISO 3104:2024-01 Procedura A","norm_bases":["PN-EN ISO 3104:2024-01 Procedura A"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Lepkość kinematyczna w temp. 40 °C\nZakres (3,500 – 5,000) mm2/s\nMetoda kapilarna PN-EN ISO 3104:2024-01 Procedura A Paliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Lepkosc kinematyczna w temp. 40 °C\nZakres (3,500 – 5,000) mm2/s\nMetoda kapilarna PN-EN ISO 3104:2024-01 Procedura A","categories":["petro"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Kinematic viscosity at 40 °C","parameters_en":[{"name":"Range","range":"(3,500 – 5,000) mm2/s"}],"search_en":"Liquid fuels: fatty acid methyl esters (FAME) Kinematic viscosity at 40 °C Capillary method Fuels Laboratory Gdynia Range PN-EN ISO 3104:2024-01 Procedura A","technique_en":"Capillary method","test_object_en":"Liquid fuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(3,500 – 5,000) mm2/s"}],"search_zh":"液体燃料：脂肪酸甲酯（FAME） 毛细管法 燃料实验室 Gdynia 范围 PN-EN ISO 3104:2024-01 Procedura A","lab_section_zh":"燃料实验室 Gdynia","technique_zh":"毛细管法","test_object_zh":"液体燃料：脂肪酸甲酯（FAME）"},{"_id":"6a7d76396040ebab2620d2a7","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Temperatura zapłonu","parameters":[{"name":"Zakres","range":"(90,0 – 180,0) °C"},{"name":"Pensky’ego-Martensa"}],"technique":"Metoda zamkniętego tygla","techniques":["Metoda zamkniętego tygla"],"computed":[],"activity":"Temperatura zapłonu\nZakres:\nZakres (90,0 – 180,0) °C\nPensky’ego-Martensa\nMetoda zamkniętego tygla","reference":"PN-EN ISO 2719:2016-08 +A1:2021-06","norm_bases":["PN-EN ISO 2719:2016-08 +A1:2021-06"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Temperatura zapłonu\nZakres:\nZakres (90,0 – 180,0) °C\nPensky’ego-Martensa\nMetoda zamkniętego tygla PN-EN ISO 2719:2016-08 +A1:2021-06 Paliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Temperatura zaplonu\nZakres:\nZakres (90,0 – 180,0) °C\nPensky’ego-Martensa\nMetoda zamknietego tygla PN-EN ISO 2719:2016-08 +A1:2021-06","categories":["petro"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Flash point","parameters_en":[{"name":"Range","range":"(90,0 – 180,0) °C"},{"name":"Pensky-Martens"}],"search_en":"Liquid fuels: fatty acid methyl esters (FAME) Flash point Closed cup method Fuels Laboratory Gdynia Range Pensky-Martens PN-EN ISO 2719:2016-08 +A1:2021-06","technique_en":"Closed cup method","test_object_en":"Liquid fuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(90,0 – 180,0) °C"},{"name":"宾斯基-马丁"}],"search_zh":"液体燃料：脂肪酸甲酯（FAME） 闪点 闭口杯法 燃料实验室 Gdynia 范围 宾斯基-马丁 PN-EN ISO 2719:2016-08 +A1:2021-06","lab_section_zh":"燃料实验室 Gdynia","methodology_zh":"闪点","test_object_zh":"液体燃料：脂肪酸甲酯（FAME）","technique_zh":"闭口杯法"},{"_id":"6a7d76396040ebab2620d2a8","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Korodujące działanie na miedź","parameters":[{"name":"klasa korozji","range":"(1 – 4)"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Korodujące działanie na miedź\nklasa korozji (1 – 4)\nMetoda wizualna","reference":"PN-EN ISO 2160:2004","norm_bases":["PN-EN ISO 2160:2004"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Korodujące działanie na miedź\nklasa korozji (1 – 4)\nMetoda wizualna PN-EN ISO 2160:2004 Paliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Korodujace dzialanie na miedz\nklasa korozji (1 – 4)\nMetoda wizualna PN-EN ISO 2160:2004","categories":["materials","petro"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Copper strip corrosion","parameters_en":[{"name":"corrosion class","range":"(1 – 4)"}],"search_en":"Liquid fuels: fatty acid methyl esters (FAME) Copper strip corrosion Visual method Fuels Laboratory Gdynia corrosion class PN-EN ISO 2160:2004","technique_en":"Visual method","test_object_en":"Liquid fuels: fatty acid methyl esters (FAME)","search_zh":"液体燃料：脂肪酸甲酯（FAME） 铜片腐蚀 目视法 燃料实验室 Gdynia 腐蚀等级 PN-EN ISO 2160:2004","technique_zh":"目视法","lab_section_zh":"燃料实验室 Gdynia","methodology_zh":"铜片腐蚀","test_object_zh":"液体燃料：脂肪酸甲酯（FAME）","parameters_zh":[{"name":"腐蚀等级","range":"(1 – 4)"}]},{"_id":"6a7d76396040ebab2620d2a9","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,010 – 0,100) % (m/m)"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (0,010 – 0,100) % (m/m)\nMetoda miareczkowania kulometrycznego","reference":"PN-EN 12937:2005+Ap1:2021-11","norm_bases":["PN-EN 12937:2005+Ap1:2021-11"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość wody\nZakres (0,010 – 0,100) % (m/m)\nMetoda miareczkowania kulometrycznego PN-EN 12937:2005+Ap1:2021-11 Paliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc wody\nZakres (0,010 – 0,100) % (m/m)\nMetoda miareczkowania kulometrycznego PN-EN 12937:2005+Ap1:2021-11","categories":["water","petro"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(0,010 – 0,100) % (m/m)"}],"search_en":"Liquid fuels: fatty acid methyl esters (FAME) Water content Coulometric titration method Fuels Laboratory Gdynia Range PN-EN 12937:2005+Ap1:2021-11","technique_en":"Coulometric titration method","test_object_en":"Liquid fuels: fatty acid methyl esters (FAME)","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,010 – 0,100) % (m/m)"}],"search_zh":"液体燃料：脂肪酸甲酯（FAME） 水分含量 库仑滴定法 燃料实验室 Gdynia 范围 PN-EN 12937:2005+Ap1:2021-11","lab_section_zh":"燃料实验室 Gdynia","technique_zh":"库仑滴定法","test_object_zh":"液体燃料：脂肪酸甲酯（FAME）"},{"_id":"6a7d76396040ebab2620d2aa","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(6,0 – 30,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (6,0 – 30,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-2:2024-11","norm_bases":["PN-EN 12662-2:2024-11"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość zanieczyszczeń\nZakres (6,0 – 30,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11 Paliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc zanieczyszczen\nZakres (6,0 – 30,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11","categories":["petro"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Impurity content","parameters_en":[{"name":"Range","range":"(6,0 – 30,0) mg/kg"}],"search_en":"Liquid fuels: fatty acid methyl esters (FAME) Impurity content Gravimetric method Fuels Laboratory Gdynia Range PN-EN 12662-2:2024-11","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(6,0 – 30,0) mg/kg"}],"search_zh":"液体燃料：脂肪酸甲酯（FAME） 杂质含量 重量法 燃料实验室 Gdynia 范围 PN-EN 12662-2:2024-11","technique_zh":"重量法","lab_section_zh":"燃料实验室 Gdynia","methodology_zh":"杂质含量","test_object_zh":"液体燃料：脂肪酸甲酯（FAME）"},{"_id":"6a7d76396040ebab2620d2ab","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(3,0 – 15,0) mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Zawartość siarki\nZakres (3,0 – 15,0) mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"PN-EN ISO 20846:2020-03","norm_bases":["PN-EN ISO 20846:2020-03"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość siarki\nZakres (3,0 – 15,0) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03 Paliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc siarki\nZakres (3,0 – 15,0) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03","categories":["petro"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(3,0 – 15,0) mg/kg"}],"search_en":"Liquid fuels: fatty acid methyl esters (FAME) Sulfur content Ultraviolet fluorescence method Fuels Laboratory Gdynia Range PN-EN ISO 20846:2020-03","technique_en":"Ultraviolet fluorescence method","test_object_en":"Liquid fuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(3,0 – 15,0) mg/kg"}],"search_zh":"液体燃料：脂肪酸甲酯（FAME） 硫含量 紫外荧光法 燃料实验室 Gdynia 范围 PN-EN ISO 20846:2020-03","lab_section_zh":"燃料实验室 Gdynia","methodology_zh":"硫含量","technique_zh":"紫外荧光法","test_object_zh":"液体燃料：脂肪酸甲酯（FAME）"},{"_id":"6a7d76396040ebab2620d2ac","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Zawartość grup węglowodorów aromatycznych","parameters":[{"name":"węglowodory aromatyczne jednopierścieniowe (MAH)"},{"name":"Zakres","range":"(6 – 30) % (m/m)"},{"name":"dwupierścieniowe węglowodory aromatyczne (DAH)","range":"(1 – 10) % (m/m)"},{"name":"trój- i wielopierścieniowe węglowodory aromatyczne (T+AH)","range":"(0 – 2) % (m/m)"},{"name":"węglowodory wielopierścieniowe (POLY-AH)","range":"(1 – 12) % (m/m)"},{"name":"Sumaryczna zawartość węglowodorów aromatycznych (z obliczeń)"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID)"],"computed":[],"activity":"Zawartość grup węglowodorów aromatycznych\nZakres:\nwęglowodory aromatyczne jednopierścieniowe (MAH)\nZakres (6 – 30) % (m/m)\ndwupierścieniowe węglowodory aromatyczne (DAH) (1 – 10) % (m/m)\ntrój- i wielopierścieniowe węglowodory aromatyczne (T+AH) (0 – 2) % (m/m)\nwęglowodory wielopierścieniowe (POLY-AH) (1 – 12) % (m/m)\nSumaryczna zawartość węglowodorów aromatycznych (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID)","reference":"PN-EN 12916:2024-08 z wyłączeniem metody B","norm_bases":["PN-EN 12916:2024-08 z wyłączeniem metody B"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Zawartość grup węglowodorów aromatycznych\nZakres:\nwęglowodory aromatyczne jednopierścieniowe (MAH)\nZakres (6 – 30) % (m/m)\ndwupierścieniowe węglowodory aromatyczne (DAH) (1 – 10) % (m/m)\ntrój- i wielopierścieniowe węglowodory aromatyczne (T+AH) (0 – 2) % (m/m)\nwęglowodory wielopierścieniowe (POLY-AH) (1 – 12) % (m/m)\nSumaryczna zawartość węglowodorów aromatycznych (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID) PN-EN 12916:2024-08 z wyłączeniem metody B Paliwa ciekle: olej napedowy Zawartosc grup weglowodorow aromatycznych\nZakres:\nweglowodory aromatyczne jednopierscieniowe (MAH)\nZakres (6 – 30) % (m/m)\ndwupierscieniowe weglowodory aromatyczne (DAH) (1 – 10) % (m/m)\ntroj- i wielopierscieniowe weglowodory aromatyczne (T+AH) (0 – 2) % (m/m)\nweglowodory wielopierscieniowe (POLY-AH) (1 – 12) % (m/m)\nSumaryczna zawartosc weglowodorow aromatycznych (z obliczen)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja refraktometryczna (HPLC-RID) PN-EN 12916:2024-08 z wylaczeniem metody B","categories":["petro"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Content of aromatic hydrocarbon groups","parameters_en":[{"name":"monocyclic aromatic hydrocarbons (MAH)"},{"name":"Range","range":"(6 – 30) % (m/m)"},{"name":"diaromatic hydrocarbons (DAH)","range":"(1 – 10) % (m/m)"},{"name":"tri- and polycyclic aromatic hydrocarbons (T+AH)","range":"(0 – 2) % (m/m)"},{"name":"polycyclic hydrocarbons (POLY-AH)","range":"(1 – 12) % (m/m)"},{"name":"Total content of aromatic hydrocarbons (calculated)"}],"search_en":"Liquid fuels: diesel fuel Content of aromatic hydrocarbon groups High-performance liquid chromatography with refractive index detection (HPLC-RID) Fuels Laboratory Gdynia monocyclic aromatic hydrocarbons (MAH) Range diaromatic hydrocarbons (DAH) tri- and polycyclic aromatic hydrocarbons (T+AH) polycyclic hydrocarbons (POLY-AH) Total content of aromatic hydrocarbons (calculated) PN-EN 12916:2024-08 z wyłączeniem metody B","technique_en":"High-performance liquid chromatography with refractive index detection (HPLC-RID)","test_object_en":"Liquid fuels: diesel fuel","parameters_zh":[{"name":"单环芳烃（MAH）"},{"name":"范围","range":"(6 – 30) % (m/m)"},{"name":"双环芳烃（DAH）","range":"(1 – 10) % (m/m)"},{"name":"三环及多环芳烃（T+AH）","range":"(0 – 2) % (m/m)"},{"name":"węglowodory wielopierścieniowe (POLY-AH)","range":"(1 – 12) % (m/m)"},{"name":"芳香烃总含量（由计算得出）"}],"search_zh":"液体燃料：柴油 芳香烃族含量 高效液相色谱-示差折光检测法（HPLC-RID） 燃料实验室 Gdynia 单环芳烃（MAH） 范围 双环芳烃（DAH） 三环及多环芳烃（T+AH） 芳香烃总含量（由计算得出） PN-EN 12916:2024-08 z wyłączeniem metody B","lab_section_zh":"燃料实验室 Gdynia","test_object_zh":"液体燃料：柴油","technique_zh":"高效液相色谱-示差折光检测法（HPLC-RID）","methodology_zh":"芳香烃族含量"},{"_id":"6a7d76396040ebab2620d2ad","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Zawartość tlenowych związków organicznych","parameters":[{"name":"Zakres","range":"(0,17 – 15,0) %(m/m), %(v/v)"},{"name":"Całkowita zawartość organicznie związanego tlenu (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość tlenowych związków organicznych\nZakres:\nZakres (0,17 – 15,0) %(m/m), %(v/v)\nCałkowita zawartość organicznie związanego tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13132:2005","norm_bases":["PN-EN 13132:2005"],"lab_section":"Pracownia Paliw Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Zawartość tlenowych związków organicznych\nZakres:\nZakres (0,17 – 15,0) %(m/m), %(v/v)\nCałkowita zawartość organicznie związanego tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13132:2005 Paliwa ciekle: benzyna bezolowiowa Zawartosc tlenowych zwiazkow organicznych\nZakres:\nZakres (0,17 – 15,0) %(m/m), %(v/v)\nCalkowita zawartosc organicznie zwiazanego tlenu (z obliczen)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13132:2005","categories":["petro"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Gdynia","methodology_en":"Content of oxygenated organic compounds","parameters_en":[{"name":"Range","range":"(0,17 – 15,0) %(m/m), %(v/v)"},{"name":"Total organically bound oxygen content (calculated)"}],"search_en":"Liquid fuels: unleaded petrol Content of oxygenated organic compounds Gas chromatography with flame ionization detection (GC-FID) Fuels Laboratory Gdynia Range Total organically bound oxygen content (calculated) PN-EN 13132:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"范围","range":"(0,17 – 15,0) %(m/m), %(v/v)"},{"name":"有机结合氧总量（由计算得出）"}],"search_zh":"液体燃料：无铅汽油 含氧有机化合物含量 气相色谱-氢火焰离子化检测法（GC-FID） 燃料实验室 Gdynia 范围 有机结合氧总量（由计算得出） PN-EN 13132:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"燃料实验室 Gdynia","test_object_zh":"液体燃料：无铅汽油","methodology_zh":"含氧有机化合物含量"},{"_id":"6a7d76396040ebab2620d2ae","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Obecność siarkowodoru","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Obecność siarkowodoru\nMetoda wizualna","reference":"PN-EN ISO 8819:2000","norm_bases":["PN-EN ISO 8819:2000"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Obecność siarkowodoru\nMetoda wizualna PN-EN ISO 8819:2000 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Obecnosc siarkowodoru\nMetoda wizualna PN-EN ISO 8819:2000","categories":["petro"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Presence of hydrogen sulfide","search_en":"Gaseous fuels: liquefied petroleum gases, LPG Presence of hydrogen sulfide Visual method Fuels Laboratory Tychy PN-EN ISO 8819:2000","technique_en":"Visual method","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","search_zh":"气体燃料：液化石油气（LPG） 硫化氢的检出 目视法 燃料实验室 Tychy PN-EN ISO 8819:2000","technique_zh":"目视法","lab_section_zh":"燃料实验室 Tychy","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"硫化氢的检出"},{"_id":"6a7d76396040ebab2620d2af","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(1,0 – 200) mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Zawartość siarki\nZakres (1,0 – 200) mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"ASTM D 6667-21","norm_bases":["ASTM D 6667-21"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Zawartość siarki\nZakres (1,0 – 200) mg/kg\nMetoda fluorescencji w nadfiolecie ASTM D 6667-21 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Zawartosc siarki\nZakres (1,0 – 200) mg/kg\nMetoda fluorescencji w nadfiolecie ASTM D 6667-21","categories":["petro"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(1,0 – 200) mg/kg"}],"search_en":"Gaseous fuels: liquefied petroleum gases, LPG Sulfur content Ultraviolet fluorescence method Fuels Laboratory Tychy Range ASTM D 6667-21","technique_en":"Ultraviolet fluorescence method","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","parameters_zh":[{"name":"范围","range":"(1,0 – 200) mg/kg"}],"search_zh":"气体燃料：液化石油气（LPG） 硫含量 紫外荧光法 燃料实验室 Tychy 范围 ASTM D 6667-21","lab_section_zh":"燃料实验室 Tychy","methodology_zh":"硫含量","test_object_zh":"气体燃料：液化石油气（LPG）","technique_zh":"紫外荧光法"},{"_id":"6a7d76396040ebab2620d2b0","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Korodujące działanie na miedź","parameters":[{"name":"klasa korozji","range":"(1 – 4)"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Korodujące działanie na miedź\nklasa korozji (1 – 4)\nMetoda wizualna","reference":"PN-EN ISO 6251:2001","norm_bases":["PN-EN ISO 6251:2001"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Korodujące działanie na miedź\nklasa korozji (1 – 4)\nMetoda wizualna PN-EN ISO 6251:2001 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Korodujace dzialanie na miedz\nklasa korozji (1 – 4)\nMetoda wizualna PN-EN ISO 6251:2001","categories":["petro","materials"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Copper strip corrosion","parameters_en":[{"name":"corrosion class","range":"(1 – 4)"}],"search_en":"Gaseous fuels: liquefied petroleum gases, LPG Copper strip corrosion Visual method Fuels Laboratory Tychy corrosion class PN-EN ISO 6251:2001","technique_en":"Visual method","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","search_zh":"气体燃料：液化石油气（LPG） 铜片腐蚀 目视法 燃料实验室 Tychy 腐蚀等级 PN-EN ISO 6251:2001","technique_zh":"目视法","lab_section_zh":"燃料实验室 Tychy","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"铜片腐蚀","parameters_zh":[{"name":"腐蚀等级","range":"(1 – 4)"}]},{"_id":"6a7d76396040ebab2620d2b1","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Obecność wody","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Obecność wody\nMetoda wizualna","reference":"PN-EN 15469:2009 | PN-C-96008:1998 p. 4.4.5","norm_bases":["PN-EN 15469:2009","PN-C-96008:1998 p. 4.4.5"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Obecność wody\nMetoda wizualna PN-EN 15469:2009 | PN-C-96008:1998 p. 4.4.5 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Obecnosc wody\nMetoda wizualna PN-EN 15469:2009 | PN-C-96008:1998 p. 4.4.5","categories":["petro","water"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Presence of water","search_en":"Gaseous fuels: liquefied petroleum gases, LPG Presence of water Visual method Fuels Laboratory Tychy PN-EN 15469:2009 | PN-C-96008:1998 p. 4.4.5","technique_en":"Visual method","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","search_zh":"气体燃料：液化石油气（LPG） 水的检出 目视法 燃料实验室 Tychy PN-EN 15469:2009 | PN-C-96008:1998 p. 4.4.5","technique_zh":"目视法","lab_section_zh":"燃料实验室 Tychy","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"水的检出"},{"_id":"6a7d76396040ebab2620d2b2","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Skład węglowodorowy","parameters":[{"name":"Zakres","range":"(0,1 – 100) % (m/m)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Skład węglowodorowy\nZakres (0,1 – 100) % (m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 27941:2015-12","norm_bases":["PN-EN 27941:2015-12"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Skład węglowodorowy\nZakres (0,1 – 100) % (m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 27941:2015-12 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Sklad weglowodorowy\nZakres (0,1 – 100) % (m/m)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 27941:2015-12","categories":["petro"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Hydrocarbon composition","parameters_en":[{"name":"Range","range":"(0,1 – 100) % (m/m)"}],"search_en":"Gaseous fuels: liquefied petroleum gases, LPG Hydrocarbon composition Gas chromatography with flame ionization detection (GC-FID) Fuels Laboratory Tychy Range PN-EN 27941:2015-12","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","parameters_zh":[{"name":"范围","range":"(0,1 – 100) % (m/m)"}],"search_zh":"气体燃料：液化石油气（LPG） 烃类组成 气相色谱-氢火焰离子化检测法（GC-FID） 燃料实验室 Tychy 范围 PN-EN 27941:2015-12","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"燃料实验室 Tychy","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"烃类组成"},{"_id":"6a7d76396040ebab2620d2b3","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Całkowita zawartość dienów","parameters":[{"name":"Zakres","range":"(0,1 – 1,0) % (mol/mol)"},{"name":"Zakres","range":"(0,1 – 1,0) % (m/m)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Całkowita zawartość dienów\nZakres:\nZakres (0,1 – 1,0) % (mol/mol)\nZakres (0,1 – 1,0) % (m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 27941:2015-12","norm_bases":["PN-EN 27941:2015-12"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Całkowita zawartość dienów\nZakres:\nZakres (0,1 – 1,0) % (mol/mol)\nZakres (0,1 – 1,0) % (m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 27941:2015-12 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Calkowita zawartosc dienow\nZakres:\nZakres (0,1 – 1,0) % (mol/mol)\nZakres (0,1 – 1,0) % (m/m)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 27941:2015-12","categories":["petro"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Total diene content","parameters_en":[{"name":"Range","range":"(0,1 – 1,0) % (mol/mol)"},{"name":"Range","range":"(0,1 – 1,0) % (m/m)"}],"search_en":"Gaseous fuels: liquefied petroleum gases, LPG Total diene content Gas chromatography with flame ionization detection (GC-FID) Fuels Laboratory Tychy Range Range PN-EN 27941:2015-12","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","parameters_zh":[{"name":"范围","range":"(0,1 – 1,0) % (mol/mol)"},{"name":"范围","range":"(0,1 – 1,0) % (m/m)"}],"search_zh":"气体燃料：液化石油气（LPG） 二烯烃总含量 气相色谱-氢火焰离子化检测法（GC-FID） 燃料实验室 Tychy 范围 范围 PN-EN 27941:2015-12","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"燃料实验室 Tychy","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"二烯烃总含量"},{"_id":"6a7d76396040ebab2620d2b4","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Skład węglowodorowy","parameters":[{"name":"Zakres","range":"(0,1 – 100,0) % (m/m)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Skład węglowodorowy\nZakres (0,1 – 100,0) % (m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"DIN 51619:2004-02","norm_bases":["DIN 51619:2004-02"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Skład węglowodorowy\nZakres (0,1 – 100,0) % (m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) DIN 51619:2004-02 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Sklad weglowodorowy\nZakres (0,1 – 100,0) % (m/m)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) DIN 51619:2004-02","categories":["petro"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Hydrocarbon composition","parameters_en":[{"name":"Range","range":"(0,1 – 100,0) % (m/m)"}],"search_en":"Gaseous fuels: liquefied petroleum gases, LPG Hydrocarbon composition Gas chromatography with flame ionization detection (GC-FID) Fuels Laboratory Tychy Range DIN 51619:2004-02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","parameters_zh":[{"name":"范围","range":"(0,1 – 100,0) % (m/m)"}],"search_zh":"气体燃料：液化石油气（LPG） 烃类组成 气相色谱-氢火焰离子化检测法（GC-FID） 燃料实验室 Tychy 范围 DIN 51619:2004-02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"燃料实验室 Tychy","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"烃类组成"},{"_id":"6a7d76396040ebab2620d2b5","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Zawartość 1,3 butadienu","parameters":[{"name":"Zakres","range":"(0,01 – 1,00) % (m/m)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość 1,3 butadienu\nZakres (0,01 – 1,00) % (m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"DIN 51619:2004-02","norm_bases":["DIN 51619:2004-02"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Zawartość 1,3 butadienu\nZakres (0,01 – 1,00) % (m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) DIN 51619:2004-02 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Zawartosc 1,3 butadienu\nZakres (0,01 – 1,00) % (m/m)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) DIN 51619:2004-02","categories":["petro"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"1,3-butadiene content","parameters_en":[{"name":"Range","range":"(0,01 – 1,00) % (m/m)"}],"search_en":"Gaseous fuels: liquefied petroleum gases, LPG 1,3-butadiene content Gas chromatography with flame ionization detection (GC-FID) Fuels Laboratory Tychy Range DIN 51619:2004-02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","parameters_zh":[{"name":"范围","range":"(0,01 – 1,00) % (m/m)"}],"search_zh":"气体燃料：液化石油气（LPG） 1,3-丁二烯含量 气相色谱-氢火焰离子化检测法（GC-FID） 燃料实验室 Tychy 范围 DIN 51619:2004-02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"燃料实验室 Tychy","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"1,3-丁二烯含量"},{"_id":"6a7d76396040ebab2620d2b6","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Całkowita zawartość dienów","parameters":[{"name":"Zakres","range":"(0,10 – 1,00) % (m/m)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Całkowita zawartość dienów\nZakres (0,10 – 1,00) % (m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"DIN 51619:2004-02","norm_bases":["DIN 51619:2004-02"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Całkowita zawartość dienów\nZakres (0,10 – 1,00) % (m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) DIN 51619:2004-02 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Calkowita zawartosc dienow\nZakres (0,10 – 1,00) % (m/m)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) DIN 51619:2004-02","categories":["petro"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Total diene content","parameters_en":[{"name":"Range","range":"(0,10 – 1,00) % (m/m)"}],"search_en":"Gaseous fuels: liquefied petroleum gases, LPG Total diene content Gas chromatography with flame ionization detection (GC-FID) Fuels Laboratory Tychy Range DIN 51619:2004-02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","parameters_zh":[{"name":"范围","range":"(0,10 – 1,00) % (m/m)"}],"search_zh":"气体燃料：液化石油气（LPG） 二烯烃总含量 气相色谱-氢火焰离子化检测法（GC-FID） 燃料实验室 Tychy 范围 DIN 51619:2004-02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"燃料实验室 Tychy","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"二烯烃总含量"},{"_id":"6a7d76396040ebab2620d2b7","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Liczba oktanowa motorowa MON (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Liczba oktanowa motorowa MON (z obliczeń)","reference":"PN-EN 589:2024-08 zał. B","norm_bases":["PN-EN 589:2024-08 zał. B"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Liczba oktanowa motorowa MON (z obliczeń) PN-EN 589:2024-08 zał. B Paliwa gazowe: skroplone gazy weglowodorowe, LPG Liczba oktanowa motorowa MON (z obliczen) PN-EN 589:2024-08 zal. B","categories":["petro"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Motor octane number MON (calculated)","search_en":"Gaseous fuels: liquefied petroleum gases, LPG Motor octane number MON (calculated) Fuels Laboratory Tychy PN-EN 589:2024-08 zał. B","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","lab_section_zh":"燃料实验室 Tychy","search_zh":"气体燃料：液化石油气（LPG） 马达法辛烷值 MON（由计算得出） 燃料实验室 Tychy PN-EN 589:2024-08 zał. B","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"马达法辛烷值 MON（由计算得出）"},{"_id":"6a7d76396040ebab2620d2b8","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Gęstość w temperaturze 15 °C (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość w temperaturze 15 °C (z obliczeń)","reference":"PN-EN ISO 8973:2000+A1:2020-10","norm_bases":["PN-EN ISO 8973:2000+A1:2020-10"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Gęstość w temperaturze 15 °C (z obliczeń) PN-EN ISO 8973:2000+A1:2020-10 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Gestosc w temperaturze 15 °C (z obliczen) PN-EN ISO 8973:2000+A1:2020-10","categories":["petro"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Density at a temperature of 15 °C (calculated)","search_en":"Gaseous fuels: liquefied petroleum gases, LPG Density at a temperature of 15 °C (calculated) Fuels Laboratory Tychy PN-EN ISO 8973:2000+A1:2020-10","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","lab_section_zh":"燃料实验室 Tychy","search_zh":"气体燃料：液化石油气（LPG） 燃料实验室 Tychy PN-EN ISO 8973:2000+A1:2020-10","test_object_zh":"气体燃料：液化石油气（LPG）"},{"_id":"6a7d76396040ebab2620d2b9","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Gęstość w temperaturze 15,6 °C (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość w temperaturze 15,6 °C (z obliczeń)","reference":"PN-C-96008:1998 p. 4.4.9","norm_bases":["PN-C-96008:1998 p. 4.4.9"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Gęstość w temperaturze 15,6 °C (z obliczeń) PN-C-96008:1998 p. 4.4.9 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Gestosc w temperaturze 15,6 °C (z obliczen) PN-C-96008:1998 p. 4.4.9","categories":["petro"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Density at a temperature of 15,6 °C (calculated)","search_en":"Gaseous fuels: liquefied petroleum gases, LPG Density at a temperature of 15,6 °C (calculated) Fuels Laboratory Tychy PN-C-96008:1998 p. 4.4.9","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","lab_section_zh":"燃料实验室 Tychy","search_zh":"气体燃料：液化石油气（LPG） 燃料实验室 Tychy PN-C-96008:1998 p. 4.4.9","test_object_zh":"气体燃料：液化石油气（LPG）"},{"_id":"6a7d76396040ebab2620d2ba","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Prężność par w temperaturze -15 °C, 40 °C i 70 °C (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Prężność par w temperaturze -15 °C, 40 °C i 70 °C (z obliczeń)","reference":"PN-C-96008:1998 p. 4.4.10","norm_bases":["PN-C-96008:1998 p. 4.4.10"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Prężność par w temperaturze -15 °C, 40 °C i 70 °C (z obliczeń) PN-C-96008:1998 p. 4.4.10 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Preznosc par w temperaturze -15 °C, 40 °C i 70 °C (z obliczen) PN-C-96008:1998 p. 4.4.10","categories":["petro"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Vapour pressure at the temperature -15 °C, 40 °C and 70 °C (calculated)","search_en":"Gaseous fuels: liquefied petroleum gases, LPG Vapour pressure at the temperature -15 °C, 40 °C and 70 °C (calculated) Fuels Laboratory Tychy PN-C-96008:1998 p. 4.4.10","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","lab_section_zh":"燃料实验室 Tychy","search_zh":"气体燃料：液化石油气（LPG） 燃料实验室 Tychy PN-C-96008:1998 p. 4.4.10","test_object_zh":"气体燃料：液化石油气（LPG）"},{"_id":"6a7d76396040ebab2620d2bb","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Prężność par, oszacowana w temperaturach: -10 °C, -5 °C, 0 °C, 10 °C, 20 °C, 37,8 °C, 40 °C, 50 °C, 70 °C (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Prężność par, oszacowana w temperaturach: -10 °C, -5 °C, 0 °C, 10 °C, 20 °C, 37,8 °C, 40 °C, 50 °C, 70 °C (z obliczeń)","reference":"PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2024-08 zał. C","norm_bases":["PN-EN ISO 8973:2000+A1:2020-10","PN-EN 589:2024-08 zał. C"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Prężność par, oszacowana w temperaturach: -10 °C, -5 °C, 0 °C, 10 °C, 20 °C, 37,8 °C, 40 °C, 50 °C, 70 °C (z obliczeń) PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2024-08 zał. C Paliwa gazowe: skroplone gazy weglowodorowe, LPG Preznosc par, oszacowana w temperaturach: -10 °C, -5 °C, 0 °C, 10 °C, 20 °C, 37,8 °C, 40 °C, 50 °C, 70 °C (z obliczen) PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2024-08 zal. C","categories":["petro"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Vapour pressure, estimated at temperatures: -10 °C, -5 °C, 0 °C, 10 °C, 20 °C, 37,8 °C, 40 °C, 50 °C, 70 °C (calculated)","search_en":"Gaseous fuels: liquefied petroleum gases, LPG Vapour pressure, estimated at temperatures: -10 °C, -5 °C, 0 °C, 10 °C, 20 °C, 37,8 °C, 40 °C, 50 °C, 70 °C (calculated) Fuels Laboratory Tychy PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2024-08 zał. C","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","lab_section_zh":"燃料实验室 Tychy","search_zh":"气体燃料：液化石油气（LPG） 燃料实验室 Tychy PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2024-08 zał. C","test_object_zh":"气体燃料：液化石油气（LPG）"},{"_id":"6a7d76396040ebab2620d2bc","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Temperatura, w której oszacowana względna prężność par jest nie mniejsza niż 150 kPa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura, w której oszacowana względna prężność par jest nie mniejsza niż 150 kPa (z obliczeń)","reference":"PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589+A1:2022-07 zał. C","norm_bases":["PN-EN ISO 8973:2000+A1:2020-10","PN-EN 589+A1:2022-07 zał. C"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Temperatura, w której oszacowana względna prężność par jest nie mniejsza niż 150 kPa (z obliczeń) PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589+A1:2022-07 zał. C Paliwa gazowe: skroplone gazy weglowodorowe, LPG Temperatura, w ktorej oszacowana wzgledna preznosc par jest nie mniejsza niz 150 kPa (z obliczen) PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589+A1:2022-07 zal. C","categories":["petro"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Temperature at which the estimated relative vapour pressure is not less than 150 kPa (calculated)","search_en":"Gaseous fuels: liquefied petroleum gases, LPG Temperature at which the estimated relative vapour pressure is not less than 150 kPa (calculated) Fuels Laboratory Tychy PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589+A1:2022-07 zał. C","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","lab_section_zh":"燃料实验室 Tychy","search_zh":"气体燃料：液化石油气（LPG） 估算相对蒸气压不低于 150 kPa 时的温度（由计算得出） 燃料实验室 Tychy PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589+A1:2022-07 zał. C","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"估算相对蒸气压不低于 150 kPa 时的温度（由计算得出）"},{"_id":"6a7d76396040ebab2620d2bd","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Wartość opałowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość opałowa (z obliczeń)","reference":"PN-C-96008:1998 p. 4.4.8","norm_bases":["PN-C-96008:1998 p. 4.4.8"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Wartość opałowa (z obliczeń) PN-C-96008:1998 p. 4.4.8 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Wartosc opalowa (z obliczen) PN-C-96008:1998 p. 4.4.8","categories":["petro"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Net calorific value (calculated)","search_en":"Gaseous fuels: liquefied petroleum gases, LPG Net calorific value (calculated) Fuels Laboratory Tychy PN-C-96008:1998 p. 4.4.8","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","methodology_zh":"低位发热量（计算值）","search_zh":"气体燃料：液化石油气（LPG） 低位发热量（计算值） 燃料实验室 Tychy PN-C-96008:1998 p. 4.4.8","lab_section_zh":"燃料实验室 Tychy","test_object_zh":"气体燃料：液化石油气（LPG）"},{"_id":"6a7d76396040ebab2620d2be","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Zapach","parameters":[],"technique":"Metoda organoleptyczna","techniques":["Metoda organoleptyczna"],"computed":[],"activity":"Zapach\nMetoda organoleptyczna","reference":"PN-EN 589:2024-08 zał. A | PN-C-96008:1998 p. 4.4.7","norm_bases":["PN-EN 589:2024-08 zał. A","PN-C-96008:1998 p. 4.4.7"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Zapach\nMetoda organoleptyczna PN-EN 589:2024-08 zał. A | PN-C-96008:1998 p. 4.4.7 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Zapach\nMetoda organoleptyczna PN-EN 589:2024-08 zal. A | PN-C-96008:1998 p. 4.4.7","categories":["petro"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Odour","search_en":"Gaseous fuels: liquefied petroleum gases, LPG Odour Organoleptic method Fuels Laboratory Tychy PN-EN 589:2024-08 zał. A | PN-C-96008:1998 p. 4.4.7","technique_en":"Organoleptic method","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","lab_section_zh":"燃料实验室 Tychy","search_zh":"气体燃料：液化石油气（LPG） 气味 感官法 燃料实验室 Tychy PN-EN 589:2024-08 zał. A | PN-C-96008:1998 p. 4.4.7","test_object_zh":"气体燃料：液化石油气（LPG）","technique_zh":"感官法","methodology_zh":"气味"},{"_id":"6a7d76396040ebab2620d2bf","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Rozpuszczalna pozostałość","parameters":[{"name":"Zakres","range":"(20 – 100) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Rozpuszczalna pozostałość\nZakres (20 – 100) mg/kg\nMetoda wagowa","reference":"PN-EN 15471:2017-08","norm_bases":["PN-EN 15471:2017-08"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Rozpuszczalna pozostałość\nZakres (20 – 100) mg/kg\nMetoda wagowa PN-EN 15471:2017-08 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Rozpuszczalna pozostalosc\nZakres (20 – 100) mg/kg\nMetoda wagowa PN-EN 15471:2017-08","categories":["petro"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Soluble residue","parameters_en":[{"name":"Range","range":"(20 – 100) mg/kg"}],"search_en":"Gaseous fuels: liquefied petroleum gases, LPG Soluble residue Gravimetric method Fuels Laboratory Tychy Range PN-EN 15471:2017-08","technique_en":"Gravimetric method","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","parameters_zh":[{"name":"范围","range":"(20 – 100) mg/kg"}],"search_zh":"气体燃料：液化石油气（LPG） 可溶性残余物 重量法 燃料实验室 Tychy 范围 PN-EN 15471:2017-08","technique_zh":"重量法","lab_section_zh":"燃料实验室 Tychy","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"可溶性残余物"},{"_id":"6a7d76396040ebab2620d2c0","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Zawartość oleju mineralnego","parameters":[{"name":"Zakres","range":"(0,0010 – 0,0100) % (m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość oleju mineralnego\nZakres (0,0010 – 0,0100) % (m/m)\nMetoda wagowa","reference":"PN-C-96008:1998 p. 4.4.4","norm_bases":["PN-C-96008:1998 p. 4.4.4"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Zawartość oleju mineralnego\nZakres (0,0010 – 0,0100) % (m/m)\nMetoda wagowa PN-C-96008:1998 p. 4.4.4 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Zawartosc oleju mineralnego\nZakres (0,0010 – 0,0100) % (m/m)\nMetoda wagowa PN-C-96008:1998 p. 4.4.4","categories":["petro"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Mineral oil content","parameters_en":[{"name":"Range","range":"(0,0010 – 0,0100) % (m/m)"}],"search_en":"Gaseous fuels: liquefied petroleum gases, LPG Mineral oil content Gravimetric method Fuels Laboratory Tychy Range PN-C-96008:1998 p. 4.4.4","technique_en":"Gravimetric method","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","parameters_zh":[{"name":"范围","range":"(0,0010 – 0,0100) % (m/m)"}],"search_zh":"气体燃料：液化石油气（LPG） 矿物油含量 重量法 燃料实验室 Tychy 范围 PN-C-96008:1998 p. 4.4.4","technique_zh":"重量法","lab_section_zh":"燃料实验室 Tychy","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"矿物油含量"},{"_id":"6a7d76396040ebab2620d2c1","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość części lotnych","parameters":[{"name":"Zakres","range":"(1,50 – 44,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość części lotnych\nZakres (1,50 – 44,00) %\nMetoda wagowa","reference":"PN-G-04516:1998","norm_bases":["PN-G-04516:1998"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość części lotnych\nZakres (1,50 – 44,00) %\nMetoda wagowa PN-G-04516:1998 Paliwa stale: wegiel kamienny Zawartosc czesci lotnych\nZakres (1,50 – 44,00) %\nMetoda wagowa PN-G-04516:1998","categories":["petro"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Volatile matter content","parameters_en":[{"name":"Range","range":"(1,50 – 44,00) %"}],"search_en":"Solid fuels: hard coal Volatile matter content Gravimetric method Fuels Laboratory Tychy Range PN-G-04516:1998","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(1,50 – 44,00) %"}],"search_zh":"固体燃料：烟煤 挥发分含量 重量法 燃料实验室 Tychy 范围 PN-G-04516:1998","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","lab_section_zh":"燃料实验室 Tychy","methodology_zh":"挥发分含量"},{"_id":"6a7d76396040ebab2620d2c2","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci całkowitej","parameters":[{"name":"Zakres","range":"(1,0 – 25,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci całkowitej\nZakres (1,0 – 25,0) %\nMetoda wagowa","reference":"PN-ISO 589:2006 met. B1","norm_bases":["PN-ISO 589:2006 met. B1"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej\nZakres (1,0 – 25,0) %\nMetoda wagowa PN-ISO 589:2006 met. B1 Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej\nZakres (1,0 – 25,0) %\nMetoda wagowa PN-ISO 589:2006 met. B1","categories":["petro"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Total moisture content","parameters_en":[{"name":"Range","range":"(1,0 – 25,0) %"}],"search_en":"Solid fuels: hard coal Total moisture content Gravimetric method Fuels Laboratory Tychy Range PN-ISO 589:2006 met. B1","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 25,0) %"}],"search_zh":"固体燃料：烟煤 全水分含量 重量法 燃料实验室 Tychy 范围 PN-ISO 589:2006 met. B1","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","lab_section_zh":"燃料实验室 Tychy"},{"_id":"6a7d76396040ebab2620d2c3","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Wskaźnik emisji CO2 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik emisji CO2 (z obliczeń)","reference":"PB-258 wyd. 2 z dn. 26.08.2024","norm_bases":["PB-258 wyd. 2 z dn. 26.08.2024"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Wskaźnik emisji CO2 (z obliczeń) PB-258 wyd. 2 z dn. 26.08.2024 Paliwa stale: wegiel kamienny Wskaznik emisji CO2 (z obliczen) PB-258 wyd. 2 z dn. 26.08.2024","categories":["environment","petro"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"CO2 emission factor (calculated)","search_en":"Solid fuels: hard coal CO2 emission factor (calculated) Fuels Laboratory Tychy PB-258 wyd. 2 z dn. 26.08.2024","test_object_en":"Solid fuels: hard coal","search_zh":"固体燃料：烟煤 燃料实验室 Tychy PB-258 wyd. 2 z dn. 26.08.2024","test_object_zh":"固体燃料：烟煤","lab_section_zh":"燃料实验室 Tychy"},{"_id":"6a7d76396040ebab2620d2c4","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Współczynnik utleniania (z obliczeń - w oparciu o zawartość węgla całkowitego w paliwie oraz stałych produktach spalania)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Współczynnik utleniania (z obliczeń - w oparciu o zawartość węgla całkowitego w paliwie oraz stałych produktach spalania)","reference":"PB-259 wyd. 2 z dn. 26.08.2024","norm_bases":["PB-259 wyd. 2 z dn. 26.08.2024"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Współczynnik utleniania (z obliczeń - w oparciu o zawartość węgla całkowitego w paliwie oraz stałych produktach spalania) PB-259 wyd. 2 z dn. 26.08.2024 Paliwa stale: wegiel kamienny Wspolczynnik utleniania (z obliczen - w oparciu o zawartosc wegla calkowitego w paliwie oraz stalych produktach spalania) PB-259 wyd. 2 z dn. 26.08.2024","categories":["petro"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Oxidation factor (calculated - based on the total carbon content in the fuel and in the solid combustion products)","search_en":"Solid fuels: hard coal Oxidation factor (calculated - based on the total carbon content in the fuel and in the solid combustion products) Fuels Laboratory Tychy PB-259 wyd. 2 z dn. 26.08.2024","test_object_en":"Solid fuels: hard coal","search_zh":"固体燃料：烟煤 燃料实验室 Tychy PB-259 wyd. 2 z dn. 26.08.2024","test_object_zh":"固体燃料：烟煤","lab_section_zh":"燃料实验室 Tychy"},{"_id":"6a7d76396040ebab2620d2c5","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zdolność spiekania","parameters":[{"name":"Zakres","range":"0 - 80"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zdolność spiekania\nZakres 0 - 80\nMetoda wagowa","reference":"PN-81/G-04518","norm_bases":["PN-81/G-04518"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zdolność spiekania\nZakres 0 - 80\nMetoda wagowa PN-81/G-04518 Paliwa stale: wegiel kamienny Zdolnosc spiekania\nZakres 0 - 80\nMetoda wagowa PN-81/G-04518","categories":["petro"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Caking ability","parameters_en":[{"name":"Range","range":"0 - 80"}],"search_en":"Solid fuels: hard coal Caking ability Gravimetric method Fuels Laboratory Tychy Range PN-81/G-04518","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"0 - 80"}],"search_zh":"固体燃料：烟煤 黏结性 重量法 燃料实验室 Tychy 范围 PN-81/G-04518","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","lab_section_zh":"燃料实验室 Tychy","methodology_zh":"黏结性"},{"_id":"6a7d76396040ebab2620d2c6","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Wskaźnik fixed carbon (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik fixed carbon (z obliczeń)","reference":"PN-G-04516:1998","norm_bases":["PN-G-04516:1998"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Wskaźnik fixed carbon (z obliczeń) PN-G-04516:1998 Paliwa stale: wegiel kamienny Wskaznik fixed carbon (z obliczen) PN-G-04516:1998","categories":["petro"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Fixed carbon index (calculated)","search_en":"Solid fuels: hard coal Fixed carbon index (calculated) Fuels Laboratory Tychy PN-G-04516:1998","test_object_en":"Solid fuels: hard coal","search_zh":"固体燃料：烟煤 固定碳指标（由计算得出） 燃料实验室 Tychy PN-G-04516:1998","test_object_zh":"固体燃料：烟煤","lab_section_zh":"燃料实验室 Tychy","methodology_zh":"固定碳指标（由计算得出）"},{"_id":"6a7d76396040ebab2620d2c7","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa stałe: koks z węgla kamiennego","methodology":"Zawartość wilgoci całkowitej","parameters":[{"name":"Zakres","range":"(1,0 – 60,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci całkowitej\nZakres (1,0 – 60,0) %\nMetoda wagowa","reference":"PN-ISO 579:2002","norm_bases":["PN-ISO 579:2002"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks z węgla kamiennego Zawartość wilgoci całkowitej\nZakres (1,0 – 60,0) %\nMetoda wagowa PN-ISO 579:2002 Paliwa stale: koks z wegla kamiennego Zawartosc wilgoci calkowitej\nZakres (1,0 – 60,0) %\nMetoda wagowa PN-ISO 579:2002","categories":["petro"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Total moisture content","parameters_en":[{"name":"Range","range":"(1,0 – 60,0) %"}],"search_en":"Solid fuels: coke from hard coal Total moisture content Gravimetric method Fuels Laboratory Tychy Range PN-ISO 579:2002","technique_en":"Gravimetric method","test_object_en":"Solid fuels: coke from hard coal","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 60,0) %"}],"search_zh":"固体燃料：烟煤焦炭 全水分含量 重量法 燃料实验室 Tychy 范围 PN-ISO 579:2002","technique_zh":"重量法","lab_section_zh":"燃料实验室 Tychy","test_object_zh":"固体燃料：烟煤焦炭"},{"_id":"6a7d76396040ebab2620d2c8","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa stałe: koks z węgla kamiennego","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,1 – 6,0) % (m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,1 – 6,0) % (m/m)\nMetoda wagowa","reference":"PN-ISO 687:2005","norm_bases":["PN-ISO 687:2005"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks z węgla kamiennego Zawartość wilgoci w próbce analitycznej\nZakres (0,1 – 6,0) % (m/m)\nMetoda wagowa PN-ISO 687:2005 Paliwa stale: koks z wegla kamiennego Zawartosc wilgoci w probce analitycznej\nZakres (0,1 – 6,0) % (m/m)\nMetoda wagowa PN-ISO 687:2005","categories":["petro"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,1 – 6,0) % (m/m)"}],"search_en":"Solid fuels: coke from hard coal Moisture content in the analytical sample Gravimetric method Fuels Laboratory Tychy Range PN-ISO 687:2005","technique_en":"Gravimetric method","test_object_en":"Solid fuels: coke from hard coal","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,1 – 6,0) % (m/m)"}],"search_zh":"固体燃料：烟煤焦炭 分析样品水分含量 重量法 燃料实验室 Tychy 范围 PN-ISO 687:2005","technique_zh":"重量法","lab_section_zh":"燃料实验室 Tychy","test_object_zh":"固体燃料：烟煤焦炭"},{"_id":"6a7d76396040ebab2620d2c9","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny i koks","methodology":"Zawartość wilgoci całkowitej","parameters":[{"name":"Zakres","range":"(1,0 – 30,0) % dla węgla kamiennego"},{"name":"Zakres","range":"(0,1 – 10,0) % dla koksu"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci całkowitej\nZakres:\nZakres (1,0 – 30,0) % dla węgla kamiennego\nZakres (0,1 – 10,0) % dla koksu\nMetoda wagowa","reference":"PN-80/G-04511 pkt. 2.3.2, pkt. 2.3.4","norm_bases":["PN-80/G-04511 pkt. 2.3.2, pkt. 2.3.4"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny i koks Zawartość wilgoci całkowitej\nZakres:\nZakres (1,0 – 30,0) % dla węgla kamiennego\nZakres (0,1 – 10,0) % dla koksu\nMetoda wagowa PN-80/G-04511 pkt. 2.3.2, pkt. 2.3.4 Paliwa stale: wegiel kamienny i koks Zawartosc wilgoci calkowitej\nZakres:\nZakres (1,0 – 30,0) % dla wegla kamiennego\nZakres (0,1 – 10,0) % dla koksu\nMetoda wagowa PN-80/G-04511 pkt. 2.3.2, pkt. 2.3.4","categories":["petro"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Total moisture content","parameters_en":[{"name":"Range","range":"(1,0 – 30,0) % dla węgla kamiennego"},{"name":"Range","range":"(0,1 – 10,0) % dla koksu"}],"search_en":"Solid fuels: hard coal and coke Total moisture content Gravimetric method Fuels Laboratory Tychy Range Range PN-80/G-04511 pkt. 2.3.2, pkt. 2.3.4","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal and coke","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 30,0) % dla węgla kamiennego"},{"name":"范围","range":"(0,1 – 10,0) % dla koksu"}],"search_zh":"固体燃料：烟煤与焦炭 全水分含量 重量法 燃料实验室 Tychy 范围 范围 PN-80/G-04511 pkt. 2.3.2, pkt. 2.3.4","technique_zh":"重量法","lab_section_zh":"燃料实验室 Tychy","test_object_zh":"固体燃料：烟煤与焦炭"},{"_id":"6a7d76396040ebab2620d2ca","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny i koks","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,10 – 10,00) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,10 – 10,00) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny i koks Zawartość wilgoci w próbce analitycznej\nZakres (0,10 – 10,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Paliwa stale: wegiel kamienny i koks Zawartosc wilgoci w probce analitycznej\nZakres (0,10 – 10,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["petro"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,10 – 10,00) %"}],"search_en":"Solid fuels: hard coal and coke Moisture content in the analytical sample Thermogravimetric method (TGA) Fuels Laboratory Tychy Range PN-G-04560:1998","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Solid fuels: hard coal and coke","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,10 – 10,00) %"}],"search_zh":"固体燃料：烟煤与焦炭 分析样品水分含量 热重法（TGA） 燃料实验室 Tychy 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）","lab_section_zh":"燃料实验室 Tychy","test_object_zh":"固体燃料：烟煤与焦炭"},{"_id":"6a7d76396040ebab2620d2cb","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny i koks","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,1 – 10,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,1 – 10,0) %\nMetoda wagowa","reference":"PN-ISO 11722:2009","norm_bases":["PN-ISO 11722:2009"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny i koks Zawartość wilgoci w próbce analitycznej\nZakres (0,1 – 10,0) %\nMetoda wagowa PN-ISO 11722:2009 Paliwa stale: wegiel kamienny i koks Zawartosc wilgoci w probce analitycznej\nZakres (0,1 – 10,0) %\nMetoda wagowa PN-ISO 11722:2009","categories":["petro"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,1 – 10,0) %"}],"search_en":"Solid fuels: hard coal and coke Moisture content in the analytical sample Gravimetric method Fuels Laboratory Tychy Range PN-ISO 11722:2009","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal and coke","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,1 – 10,0) %"}],"search_zh":"固体燃料：烟煤与焦炭 分析样品水分含量 重量法 燃料实验室 Tychy 范围 PN-ISO 11722:2009","technique_zh":"重量法","lab_section_zh":"燃料实验室 Tychy","test_object_zh":"固体燃料：烟煤与焦炭"},{"_id":"6a7d76396040ebab2620d2cc","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny i koks","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(0,10 – 55,00) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość popiołu\nZakres (0,10 – 55,00) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny i koks Zawartość popiołu\nZakres (0,10 – 55,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Paliwa stale: wegiel kamienny i koks Zawartosc popiolu\nZakres (0,10 – 55,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["petro"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(0,10 – 55,00) %"}],"search_en":"Solid fuels: hard coal and coke Ash content Thermogravimetric method (TGA) Fuels Laboratory Tychy Range PN-G-04560:1998","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Solid fuels: hard coal and coke","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,10 – 55,00) %"}],"search_zh":"固体燃料：烟煤与焦炭 灰分含量 热重法（TGA） 燃料实验室 Tychy 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）","lab_section_zh":"燃料实验室 Tychy","test_object_zh":"固体燃料：烟煤与焦炭"},{"_id":"6a7d76396040ebab2620d2cd","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny i koks","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(1,0 – 55,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu\nZakres (1,0 – 55,0) %\nMetoda wagowa","reference":"PN-ISO 1171:2002","norm_bases":["PN-ISO 1171:2002"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny i koks Zawartość popiołu\nZakres (1,0 – 55,0) %\nMetoda wagowa PN-ISO 1171:2002 Paliwa stale: wegiel kamienny i koks Zawartosc popiolu\nZakres (1,0 – 55,0) %\nMetoda wagowa PN-ISO 1171:2002","categories":["petro"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(1,0 – 55,0) %"}],"search_en":"Solid fuels: hard coal and coke Ash content Gravimetric method Fuels Laboratory Tychy Range PN-ISO 1171:2002","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal and coke","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 55,0) %"}],"search_zh":"固体燃料：烟煤与焦炭 灰分含量 重量法 燃料实验室 Tychy 范围 PN-ISO 1171:2002","technique_zh":"重量法","lab_section_zh":"燃料实验室 Tychy","test_object_zh":"固体燃料：烟煤与焦炭"},{"_id":"6a7d76396040ebab2620d2ce","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny i koks","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(14000 – 35000) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres:\nZakres (14000 – 35000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-81/G-04513 | PN-ISO 1928:2020-05","norm_bases":["PN-81/G-04513","PN-ISO 1928:2020-05"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny i koks Ciepło spalania\nZakres:\nZakres (14000 – 35000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-81/G-04513 | PN-ISO 1928:2020-05 Paliwa stale: wegiel kamienny i koks Cieplo spalania\nZakres:\nZakres (14000 – 35000) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-81/G-04513 | PN-ISO 1928:2020-05","categories":["petro"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(14000 – 35000) kJ/kg"},{"name":"Net calorific value (calculated)"}],"search_en":"Solid fuels: hard coal and coke Gross calorific value Calorimetric method Fuels Laboratory Tychy Range Net calorific value (calculated) PN-81/G-04513 | PN-ISO 1928:2020-05","technique_en":"Calorimetric method","test_object_en":"Solid fuels: hard coal and coke","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(14000 – 35000) kJ/kg"},{"name":"低位发热量（计算值）"}],"search_zh":"固体燃料：烟煤与焦炭 高位发热量 量热法 燃料实验室 Tychy 范围 低位发热量（计算值） PN-81/G-04513 | PN-ISO 1928:2020-05","technique_zh":"量热法","lab_section_zh":"燃料实验室 Tychy","test_object_zh":"固体燃料：烟煤与焦炭"},{"_id":"6a7d76396040ebab2620d2cf","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny i koks","methodology":"Zawartość części lotnych","parameters":[{"name":"Zakres","range":"(1,6 – 44,0) % dla węgla kamiennego"},{"name":"Zakres","range":"(0,5 – 10,0) % dla koksu"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość części lotnych\nZakres:\nZakres (1,6 – 44,0) % dla węgla kamiennego\nZakres (0,5 – 10,0) % dla koksu\nMetoda wagowa","reference":"ISO 562:2024-08","norm_bases":["ISO 562:2024-08"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny i koks Zawartość części lotnych\nZakres:\nZakres (1,6 – 44,0) % dla węgla kamiennego\nZakres (0,5 – 10,0) % dla koksu\nMetoda wagowa ISO 562:2024-08 Paliwa stale: wegiel kamienny i koks Zawartosc czesci lotnych\nZakres:\nZakres (1,6 – 44,0) % dla wegla kamiennego\nZakres (0,5 – 10,0) % dla koksu\nMetoda wagowa ISO 562:2024-08","categories":["petro"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Volatile matter content","parameters_en":[{"name":"Range","range":"(1,6 – 44,0) % dla węgla kamiennego"},{"name":"Range","range":"(0,5 – 10,0) % dla koksu"}],"search_en":"Solid fuels: hard coal and coke Volatile matter content Gravimetric method Fuels Laboratory Tychy Range Range ISO 562:2024-08","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal and coke","parameters_zh":[{"name":"范围","range":"(1,6 – 44,0) % dla węgla kamiennego"},{"name":"范围","range":"(0,5 – 10,0) % dla koksu"}],"search_zh":"固体燃料：烟煤与焦炭 挥发分含量 重量法 燃料实验室 Tychy 范围 范围 ISO 562:2024-08","technique_zh":"重量法","lab_section_zh":"燃料实验室 Tychy","methodology_zh":"挥发分含量","test_object_zh":"固体燃料：烟煤与焦炭"},{"_id":"6a7d76396040ebab2620d2d0","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny i koks","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,10 – 2,50) % (m/m)"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,10 – 2,50) % (m/m)\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001 | ASTM D 4239-18 Ɛ1 (metoda A)","norm_bases":["PN-G-04584:2001","ASTM D 4239-18 Ɛ1 (metoda A)"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny i koks Zawartość siarki całkowitej\nZakres (0,10 – 2,50) % (m/m)\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 | ASTM D 4239-18 Ɛ1 (metoda A) Paliwa stale: wegiel kamienny i koks Zawartosc siarki calkowitej\nZakres (0,10 – 2,50) % (m/m)\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001 | ASTM D 4239-18 Ɛ1 (metoda A)","categories":["petro"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,10 – 2,50) % (m/m)"}],"search_en":"Solid fuels: hard coal and coke Total sulfur content High-temperature combustion with IR detection Fuels Laboratory Tychy Range PN-G-04584:2001 | ASTM D 4239-18 Ɛ1 (metoda A)","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal and coke","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,10 – 2,50) % (m/m)"}],"search_zh":"固体燃料：烟煤与焦炭 全硫含量 高温燃烧红外检测法 燃料实验室 Tychy 范围 PN-G-04584:2001 | ASTM D 4239-18 Ɛ1 (metoda A)","technique_zh":"高温燃烧红外检测法","lab_section_zh":"燃料实验室 Tychy","test_object_zh":"固体燃料：烟煤与焦炭"},{"_id":"6a7d76396040ebab2620d2d1","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny i koks","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,20 – 2,50) % (m/m)"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,20 – 2,50) % (m/m)\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"ISO 19579:2006","norm_bases":["ISO 19579:2006"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny i koks Zawartość siarki całkowitej\nZakres (0,20 – 2,50) % (m/m)\nMetoda wysokotemperaturowego spalania z detekcją IR ISO 19579:2006 Paliwa stale: wegiel kamienny i koks Zawartosc siarki calkowitej\nZakres (0,20 – 2,50) % (m/m)\nMetoda wysokotemperaturowego spalania z detekcja IR ISO 19579:2006","categories":["petro"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,20 – 2,50) % (m/m)"}],"search_en":"Solid fuels: hard coal and coke Total sulfur content High-temperature combustion with IR detection Fuels Laboratory Tychy Range ISO 19579:2006","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal and coke","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,20 – 2,50) % (m/m)"}],"search_zh":"固体燃料：烟煤与焦炭 全硫含量 高温燃烧红外检测法 燃料实验室 Tychy 范围 ISO 19579:2006","technique_zh":"高温燃烧红外检测法","lab_section_zh":"燃料实验室 Tychy","test_object_zh":"固体燃料：烟煤与焦炭"},{"_id":"6a7d76396040ebab2620d2d2","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny i koks","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(40,0 – 100,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres (40,0 – 100,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998 PKN-ISO/TS 12902:2007","norm_bases":["PN-G-04571:1998 PKN-ISO/TS 12902:2007"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny i koks Zawartość węgla całkowitego\nZakres (40,0 – 100,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 PKN-ISO/TS 12902:2007 Paliwa stale: wegiel kamienny i koks Zawartosc wegla calkowitego\nZakres (40,0 – 100,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998 PKN-ISO/TS 12902:2007","categories":["petro"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(40,0 – 100,0) %"}],"search_en":"Solid fuels: hard coal and coke Total carbon content High-temperature combustion with IR detection Fuels Laboratory Tychy Range PN-G-04571:1998 PKN-ISO/TS 12902:2007","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal and coke","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(40,0 – 100,0) %"}],"search_zh":"固体燃料：烟煤与焦炭 总碳含量 高温燃烧红外检测法 燃料实验室 Tychy 范围 PN-G-04571:1998 PKN-ISO/TS 12902:2007","technique_zh":"高温燃烧红外检测法","lab_section_zh":"燃料实验室 Tychy","test_object_zh":"固体燃料：烟煤与焦炭"},{"_id":"6a7d76396040ebab2620d2d3","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny i koks","methodology":"Zawartość wodoru","parameters":[{"name":"Zakres","range":"(0,10 – 5,60) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość wodoru\nZakres (0,10 – 5,60) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998 PKN-ISO/TS 12902:2007","norm_bases":["PN-G-04571:1998 PKN-ISO/TS 12902:2007"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny i koks Zawartość wodoru\nZakres (0,10 – 5,60) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 PKN-ISO/TS 12902:2007 Paliwa stale: wegiel kamienny i koks Zawartosc wodoru\nZakres (0,10 – 5,60) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998 PKN-ISO/TS 12902:2007","categories":["petro"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Hydrogen content","parameters_en":[{"name":"Range","range":"(0,10 – 5,60) %"}],"search_en":"Solid fuels: hard coal and coke Hydrogen content High-temperature combustion with IR detection Fuels Laboratory Tychy Range PN-G-04571:1998 PKN-ISO/TS 12902:2007","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal and coke","parameters_zh":[{"name":"范围","range":"(0,10 – 5,60) %"}],"search_zh":"固体燃料：烟煤与焦炭 氢含量 高温燃烧红外检测法 燃料实验室 Tychy 范围 PN-G-04571:1998 PKN-ISO/TS 12902:2007","technique_zh":"高温燃烧红外检测法","lab_section_zh":"燃料实验室 Tychy","methodology_zh":"氢含量","test_object_zh":"固体燃料：烟煤与焦炭"},{"_id":"6a7d76396040ebab2620d2d4","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny i koks","methodology":"Zawartość chloru","parameters":[{"name":"Zakres","range":"(0,03 – 0,50) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość chloru\nZakres (0,03 – 0,50) %\nMetoda miareczkowa","reference":"PN-ISO 587:2000 p. 7.2.1","norm_bases":["PN-ISO 587:2000 p. 7.2.1"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny i koks Zawartość chloru\nZakres (0,03 – 0,50) %\nMetoda miareczkowa PN-ISO 587:2000 p. 7.2.1 Paliwa stale: wegiel kamienny i koks Zawartosc chloru\nZakres (0,03 – 0,50) %\nMetoda miareczkowa PN-ISO 587:2000 p. 7.2.1","categories":["petro"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Chlorine content","parameters_en":[{"name":"Range","range":"(0,03 – 0,50) %"}],"search_en":"Solid fuels: hard coal and coke Chlorine content Titrimetric method Fuels Laboratory Tychy Range PN-ISO 587:2000 p. 7.2.1","technique_en":"Titrimetric method","test_object_en":"Solid fuels: hard coal and coke","parameters_zh":[{"name":"范围","range":"(0,03 – 0,50) %"}],"search_zh":"固体燃料：烟煤与焦炭 氯含量 滴定法 燃料实验室 Tychy 范围 PN-ISO 587:2000 p. 7.2.1","technique_zh":"滴定法","lab_section_zh":"燃料实验室 Tychy","methodology_zh":"氯含量","test_object_zh":"固体燃料：烟煤与焦炭"},{"_id":"6a7d76396040ebab2620d2d5","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Odpady O) kod: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,10 – 10,00) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,10 – 10,00) %\nMetoda termograwimetryczna (TGA)","reference":"PB-72 wyd. 2 z dn. 26.08.2024","norm_bases":["PB-72 wyd. 2 z dn. 26.08.2024"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":"O) Kody odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O) kod: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80 Zawartość wilgoci w próbce analitycznej\nZakres (0,10 – 10,00) %\nMetoda termograwimetryczna (TGA) PB-72 wyd. 2 z dn. 26.08.2024 Odpady O) kod: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80 Zawartosc wilgoci w probce analitycznej\nZakres (0,10 – 10,00) %\nMetoda termograwimetryczna (TGA) PB-72 wyd. 2 z dn. 26.08.2024","categories":["environment"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,10 – 10,00) %"}],"regulatory_area_en":"O) Waste codes given according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Waste O) code: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80 Moisture content in the analytical sample Thermogravimetric method (TGA) Fuels Laboratory Tychy O) Waste codes given according to the Regulation of the Minister of Climate on the waste catalogue. Range PB-72 wyd. 2 z dn. 26.08.2024","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Waste O) code: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,10 – 10,00) %"}],"search_zh":"废物 O) 代码：10 01 01、10 01 02、10 01 03、10 01 15、10 01 17、10 01 80 分析样品水分含量 热重法（TGA） 燃料实验室 Tychy O) 废物代码依据气候部长关于废物名录的条例给出。 范围 PB-72 wyd. 2 z dn. 26.08.2024","technique_zh":"热重法（TGA）","lab_section_zh":"燃料实验室 Tychy","regulatory_area_zh":"O) 废物代码依据气候部长关于废物名录的条例给出。","test_object_zh":"废物 O) 代码：10 01 01、10 01 02、10 01 03、10 01 15、10 01 17、10 01 80"},{"_id":"6a7d76396040ebab2620d2d6","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Odpady O) kod: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(40,00 – 99,90) % (m/m)"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość popiołu\nZakres (40,00 – 99,90) % (m/m)\nMetoda termograwimetryczna (TGA)","reference":"PB-347 wyd. 2 z dn. 26.08.2024","norm_bases":["PB-347 wyd. 2 z dn. 26.08.2024"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":"O) Kody odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O) kod: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80 Zawartość popiołu\nZakres (40,00 – 99,90) % (m/m)\nMetoda termograwimetryczna (TGA) PB-347 wyd. 2 z dn. 26.08.2024 Odpady O) kod: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80 Zawartosc popiolu\nZakres (40,00 – 99,90) % (m/m)\nMetoda termograwimetryczna (TGA) PB-347 wyd. 2 z dn. 26.08.2024","categories":["environment"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(40,00 – 99,90) % (m/m)"}],"regulatory_area_en":"O) Waste codes given according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Waste O) code: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80 Ash content Thermogravimetric method (TGA) Fuels Laboratory Tychy O) Waste codes given according to the Regulation of the Minister of Climate on the waste catalogue. Range PB-347 wyd. 2 z dn. 26.08.2024","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Waste O) code: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(40,00 – 99,90) % (m/m)"}],"search_zh":"废物 O) 代码：10 01 01、10 01 02、10 01 03、10 01 15、10 01 17、10 01 80 灰分含量 热重法（TGA） 燃料实验室 Tychy O) 废物代码依据气候部长关于废物名录的条例给出。 范围 PB-347 wyd. 2 z dn. 26.08.2024","technique_zh":"热重法（TGA）","lab_section_zh":"燃料实验室 Tychy","regulatory_area_zh":"O) 废物代码依据气候部长关于废物名录的条例给出。","test_object_zh":"废物 O) 代码：10 01 01、10 01 02、10 01 03、10 01 15、10 01 17、10 01 80"},{"_id":"6a7d76396040ebab2620d2d7","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Odpady O) kod: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(0,3 – 40,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres (0,3 – 40,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PB-73 wyd. 2 z dn. 15.03.2024","norm_bases":["PB-73 wyd. 2 z dn. 15.03.2024"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":"O) Kody odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O) kod: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80 Zawartość węgla całkowitego\nZakres (0,3 – 40,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PB-73 wyd. 2 z dn. 15.03.2024 Odpady O) kod: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80 Zawartosc wegla calkowitego\nZakres (0,3 – 40,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PB-73 wyd. 2 z dn. 15.03.2024","categories":["environment"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(0,3 – 40,0) %"}],"regulatory_area_en":"O) Waste codes given according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Waste O) code: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80 Total carbon content High-temperature combustion with IR detection Fuels Laboratory Tychy O) Waste codes given according to the Regulation of the Minister of Climate on the waste catalogue. Range PB-73 wyd. 2 z dn. 15.03.2024","technique_en":"High-temperature combustion with IR detection","test_object_en":"Waste O) code: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(0,3 – 40,0) %"}],"search_zh":"废物 O) 代码：10 01 01、10 01 02、10 01 03、10 01 15、10 01 17、10 01 80 总碳含量 高温燃烧红外检测法 燃料实验室 Tychy O) 废物代码依据气候部长关于废物名录的条例给出。 范围 PB-73 wyd. 2 z dn. 15.03.2024","technique_zh":"高温燃烧红外检测法","lab_section_zh":"燃料实验室 Tychy","regulatory_area_zh":"O) 废物代码依据气候部长关于废物名录的条例给出。","test_object_zh":"废物 O) 代码：10 01 01、10 01 02、10 01 03、10 01 15、10 01 17、10 01 80"},{"_id":"6a7d76396040ebab2620d2d8","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Odpady O) kod: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80","methodology":"Zawartość wilgoci całkowitej","parameters":[{"name":"Zakres","range":"(0,1 – 40,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci całkowitej\nZakres (0,1 – 40,0) %\nMetoda wagowa","reference":"PB-90 wyd. 2 z dn. 26.08.2024","norm_bases":["PB-90 wyd. 2 z dn. 26.08.2024"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":"O) Kody odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O) kod: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80 Zawartość wilgoci całkowitej\nZakres (0,1 – 40,0) %\nMetoda wagowa PB-90 wyd. 2 z dn. 26.08.2024 Odpady O) kod: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80 Zawartosc wilgoci calkowitej\nZakres (0,1 – 40,0) %\nMetoda wagowa PB-90 wyd. 2 z dn. 26.08.2024","categories":["environment"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Total moisture content","parameters_en":[{"name":"Range","range":"(0,1 – 40,0) %"}],"regulatory_area_en":"O) Waste codes given according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Waste O) code: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80 Total moisture content Gravimetric method Fuels Laboratory Tychy O) Waste codes given according to the Regulation of the Minister of Climate on the waste catalogue. Range PB-90 wyd. 2 z dn. 26.08.2024","technique_en":"Gravimetric method","test_object_en":"Waste O) code: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(0,1 – 40,0) %"}],"search_zh":"废物 O) 代码：10 01 01、10 01 02、10 01 03、10 01 15、10 01 17、10 01 80 全水分含量 重量法 燃料实验室 Tychy O) 废物代码依据气候部长关于废物名录的条例给出。 范围 PB-90 wyd. 2 z dn. 26.08.2024","technique_zh":"重量法","lab_section_zh":"燃料实验室 Tychy","regulatory_area_zh":"O) 废物代码依据气候部长关于废物名录的条例给出。","test_object_zh":"废物 O) 代码：10 01 01、10 01 02、10 01 03、10 01 15、10 01 17、10 01 80"},{"_id":"6a7d76396040ebab2620d2d9","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwa stałe","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(1,00 – 20,00) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (1,00 – 20,00) %\nMetoda termograwimetryczna (TGA)","reference":"PB-98 wyd. III z dn. 21.05.2013","norm_bases":["PB-98 wyd. III z dn. 21.05.2013"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwa stałe Zawartość wilgoci w próbce analitycznej\nZakres (1,00 – 20,00) %\nMetoda termograwimetryczna (TGA) PB-98 wyd. III z dn. 21.05.2013 Paliwa stale: biomasa stala - biopaliwa stale Zawartosc wilgoci w probce analitycznej\nZakres (1,00 – 20,00) %\nMetoda termograwimetryczna (TGA) PB-98 wyd. III z dn. 21.05.2013","categories":["petro"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(1,00 – 20,00) %"}],"search_en":"Solid fuels: solid biomass - solid biofuels Moisture content in the analytical sample Thermogravimetric method (TGA) Fuels Laboratory Tychy Range PB-98 wyd. III z dn. 21.05.2013","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Solid fuels: solid biomass - solid biofuels","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(1,00 – 20,00) %"}],"search_zh":"固体燃料：固体生物质 － 固体生物燃料 分析样品水分含量 热重法（TGA） 燃料实验室 Tychy 范围 PB-98 wyd. III z dn. 21.05.2013","technique_zh":"热重法（TGA）","lab_section_zh":"燃料实验室 Tychy","test_object_zh":"固体燃料：固体生物质 － 固体生物燃料"},{"_id":"6a7d76396040ebab2620d2da","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwa stałe","methodology":"Zawartość wilgoci całkowitej","parameters":[{"name":"Zakres","range":"(3,0 – 85,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci całkowitej\nZakres (3,0 – 85,0) %\nMetoda wagowa","reference":"PN-EN ISO 18134-2:2024-10","norm_bases":["PN-EN ISO 18134-2:2024-10"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwa stałe Zawartość wilgoci całkowitej\nZakres (3,0 – 85,0) %\nMetoda wagowa PN-EN ISO 18134-2:2024-10 Paliwa stale: biomasa stala - biopaliwa stale Zawartosc wilgoci calkowitej\nZakres (3,0 – 85,0) %\nMetoda wagowa PN-EN ISO 18134-2:2024-10","categories":["petro"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Total moisture content","parameters_en":[{"name":"Range","range":"(3,0 – 85,0) %"}],"search_en":"Solid fuels: solid biomass - solid biofuels Total moisture content Gravimetric method Fuels Laboratory Tychy Range PN-EN ISO 18134-2:2024-10","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid biomass - solid biofuels","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(3,0 – 85,0) %"}],"search_zh":"固体燃料：固体生物质 － 固体生物燃料 全水分含量 重量法 燃料实验室 Tychy 范围 PN-EN ISO 18134-2:2024-10","technique_zh":"重量法","lab_section_zh":"燃料实验室 Tychy","test_object_zh":"固体燃料：固体生物质 － 固体生物燃料"},{"_id":"6a7d76396040ebab2620d2db","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwa stałe","methodology":"Zawartość wodoru","parameters":[{"name":"Zakres","range":"(3,0 – 8,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość wodoru\nZakres (3,0 – 8,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 16948:2015-07","norm_bases":["PN-EN ISO 16948:2015-07"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwa stałe Zawartość wodoru\nZakres (3,0 – 8,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 16948:2015-07 Paliwa stale: biomasa stala - biopaliwa stale Zawartosc wodoru\nZakres (3,0 – 8,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 16948:2015-07","categories":["petro"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Hydrogen content","parameters_en":[{"name":"Range","range":"(3,0 – 8,0) %"}],"search_en":"Solid fuels: solid biomass - solid biofuels Hydrogen content High-temperature combustion with IR detection Fuels Laboratory Tychy Range PN-EN ISO 16948:2015-07","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: solid biomass - solid biofuels","parameters_zh":[{"name":"范围","range":"(3,0 – 8,0) %"}],"search_zh":"固体燃料：固体生物质 － 固体生物燃料 氢含量 高温燃烧红外检测法 燃料实验室 Tychy 范围 PN-EN ISO 16948:2015-07","technique_zh":"高温燃烧红外检测法","lab_section_zh":"燃料实验室 Tychy","methodology_zh":"氢含量","test_object_zh":"固体燃料：固体生物质 － 固体生物燃料"},{"_id":"6a7d76396040ebab2620d2dc","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwa stałe","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(0,1 – 45,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu\nZakres (0,1 – 45,0) %\nMetoda wagowa","reference":"PN-EN ISO 18122:2023-05","norm_bases":["PN-EN ISO 18122:2023-05"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwa stałe Zawartość popiołu\nZakres (0,1 – 45,0) %\nMetoda wagowa PN-EN ISO 18122:2023-05 Paliwa stale: biomasa stala - biopaliwa stale Zawartosc popiolu\nZakres (0,1 – 45,0) %\nMetoda wagowa PN-EN ISO 18122:2023-05","categories":["petro"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(0,1 – 45,0) %"}],"search_en":"Solid fuels: solid biomass - solid biofuels Ash content Gravimetric method Fuels Laboratory Tychy Range PN-EN ISO 18122:2023-05","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid biomass - solid biofuels","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,1 – 45,0) %"}],"search_zh":"固体燃料：固体生物质 － 固体生物燃料 灰分含量 重量法 燃料实验室 Tychy 范围 PN-EN ISO 18122:2023-05","technique_zh":"重量法","lab_section_zh":"燃料实验室 Tychy","test_object_zh":"固体燃料：固体生物质 － 固体生物燃料"},{"_id":"6a7d76396040ebab2620d2dd","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwa stałe","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(0,02 – 0,20) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki\nZakres (0,02 – 0,20) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 16994:2016-10 p. 4.4","norm_bases":["PN-EN ISO 16994:2016-10 p. 4.4"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwa stałe Zawartość siarki\nZakres (0,02 – 0,20) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 16994:2016-10 p. 4.4 Paliwa stale: biomasa stala - biopaliwa stale Zawartosc siarki\nZakres (0,02 – 0,20) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 16994:2016-10 p. 4.4","categories":["petro"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(0,02 – 0,20) %"}],"search_en":"Solid fuels: solid biomass - solid biofuels Sulfur content High-temperature combustion with IR detection Fuels Laboratory Tychy Range PN-EN ISO 16994:2016-10 p. 4.4","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: solid biomass - solid biofuels","parameters_zh":[{"name":"范围","range":"(0,02 – 0,20) %"}],"search_zh":"固体燃料：固体生物质 － 固体生物燃料 硫含量 高温燃烧红外检测法 燃料实验室 Tychy 范围 PN-EN ISO 16994:2016-10 p. 4.4","technique_zh":"高温燃烧红外检测法","lab_section_zh":"燃料实验室 Tychy","methodology_zh":"硫含量","test_object_zh":"固体燃料：固体生物质 － 固体生物燃料"},{"_id":"6a7d76396040ebab2620d2de","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwa stałe","methodology":"Zawartość węgla","parameters":[{"name":"Zakres","range":"(30,0 – 50,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla\nZakres (30,0 – 50,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 16948:2015-07","norm_bases":["PN-EN ISO 16948:2015-07"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwa stałe Zawartość węgla\nZakres (30,0 – 50,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 16948:2015-07 Paliwa stale: biomasa stala - biopaliwa stale Zawartosc wegla\nZakres (30,0 – 50,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 16948:2015-07","categories":["petro"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Carbon content","parameters_en":[{"name":"Range","range":"(30,0 – 50,0) %"}],"search_en":"Solid fuels: solid biomass - solid biofuels Carbon content High-temperature combustion with IR detection Fuels Laboratory Tychy Range PN-EN ISO 16948:2015-07","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: solid biomass - solid biofuels","parameters_zh":[{"name":"范围","range":"(30,0 – 50,0) %"}],"search_zh":"固体燃料：固体生物质 － 固体生物燃料 碳含量 高温燃烧红外检测法 燃料实验室 Tychy 范围 PN-EN ISO 16948:2015-07","technique_zh":"高温燃烧红外检测法","lab_section_zh":"燃料实验室 Tychy","methodology_zh":"碳含量","test_object_zh":"固体燃料：固体生物质 － 固体生物燃料"},{"_id":"6a7d76396040ebab2620d2df","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwa stałe","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(5000 – 22000) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres:\nZakres (5000 – 22000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-EN ISO 18125:2017-07","norm_bases":["PN-EN ISO 18125:2017-07"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwa stałe Ciepło spalania\nZakres:\nZakres (5000 – 22000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-EN ISO 18125:2017-07 Paliwa stale: biomasa stala - biopaliwa stale Cieplo spalania\nZakres:\nZakres (5000 – 22000) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-EN ISO 18125:2017-07","categories":["petro"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(5000 – 22000) kJ/kg"},{"name":"Net calorific value (calculated)"}],"search_en":"Solid fuels: solid biomass - solid biofuels Gross calorific value Calorimetric method Fuels Laboratory Tychy Range Net calorific value (calculated) PN-EN ISO 18125:2017-07","technique_en":"Calorimetric method","test_object_en":"Solid fuels: solid biomass - solid biofuels","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(5000 – 22000) kJ/kg"},{"name":"低位发热量（计算值）"}],"search_zh":"固体燃料：固体生物质 － 固体生物燃料 高位发热量 量热法 燃料实验室 Tychy 范围 低位发热量（计算值） PN-EN ISO 18125:2017-07","technique_zh":"量热法","lab_section_zh":"燃料实验室 Tychy","test_object_zh":"固体燃料：固体生物质 － 固体生物燃料"},{"_id":"6a7d76396040ebab2620d2e0","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwa stałe","methodology":"Zawartość części lotnych","parameters":[{"name":"Zakres","range":"(60,0 – 85,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość części lotnych\nZakres (60,0 – 85,0) %\nMetoda wagowa","reference":"PN-EN ISO 18123:2023-10","norm_bases":["PN-EN ISO 18123:2023-10"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwa stałe Zawartość części lotnych\nZakres (60,0 – 85,0) %\nMetoda wagowa PN-EN ISO 18123:2023-10 Paliwa stale: biomasa stala - biopaliwa stale Zawartosc czesci lotnych\nZakres (60,0 – 85,0) %\nMetoda wagowa PN-EN ISO 18123:2023-10","categories":["petro"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Volatile matter content","parameters_en":[{"name":"Range","range":"(60,0 – 85,0) %"}],"search_en":"Solid fuels: solid biomass - solid biofuels Volatile matter content Gravimetric method Fuels Laboratory Tychy Range PN-EN ISO 18123:2023-10","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid biomass - solid biofuels","parameters_zh":[{"name":"范围","range":"(60,0 – 85,0) %"}],"search_zh":"固体燃料：固体生物质 － 固体生物燃料 挥发分含量 重量法 燃料实验室 Tychy 范围 PN-EN ISO 18123:2023-10","technique_zh":"重量法","lab_section_zh":"燃料实验室 Tychy","methodology_zh":"挥发分含量","test_object_zh":"固体燃料：固体生物质 － 固体生物燃料"},{"_id":"6a7d76396040ebab2620d2e1","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwa stałe","methodology":"Zawartość chloru","parameters":[{"name":"Zakres","range":"(0,04 – 0,50) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość chloru\nZakres (0,04 – 0,50) %\nMetoda miareczkowa","reference":"PB-86 wyd. 3 z dn. 06.10.2025","norm_bases":["PB-86 wyd. 3 z dn. 06.10.2025"],"lab_section":"Pracownia Paliw Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwa stałe Zawartość chloru\nZakres (0,04 – 0,50) %\nMetoda miareczkowa PB-86 wyd. 3 z dn. 06.10.2025 Paliwa stale: biomasa stala - biopaliwa stale Zawartosc chloru\nZakres (0,04 – 0,50) %\nMetoda miareczkowa PB-86 wyd. 3 z dn. 06.10.2025","categories":["petro"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fuels Laboratory Tychy","methodology_en":"Chlorine content","parameters_en":[{"name":"Range","range":"(0,04 – 0,50) %"}],"search_en":"Solid fuels: solid biomass - solid biofuels Chlorine content Titrimetric method Fuels Laboratory Tychy Range PB-86 wyd. 3 z dn. 06.10.2025","technique_en":"Titrimetric method","test_object_en":"Solid fuels: solid biomass - solid biofuels","parameters_zh":[{"name":"范围","range":"(0,04 – 0,50) %"}],"search_zh":"固体燃料：固体生物质 － 固体生物燃料 氯含量 滴定法 燃料实验室 Tychy 范围 PB-86 wyd. 3 z dn. 06.10.2025","technique_zh":"滴定法","lab_section_zh":"燃料实验室 Tychy","methodology_zh":"氯含量","test_object_zh":"固体燃料：固体生物质 － 固体生物燃料"},{"_id":"6a7d76396040ebab2620d2e2","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Mięso, Ryby, Jaja","methodology":"Obecność pozostałości antybiotyków","parameters":[],"technique":"Metoda dyfuzyjna","techniques":["Metoda dyfuzyjna"],"computed":[],"activity":"Obecność pozostałości antybiotyków\nMetoda dyfuzyjna","reference":"PB-216 wyd. II z dn. 23.10.2015 w oparciu o instrukcję producenta Premi Test","norm_bases":["PB-216 wyd. II z dn. 23.10.2015 w oparciu o instrukcję producenta Premi Test"],"lab_section":"Pracownia Mikrobiologii Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso, Ryby, Jaja Obecność pozostałości antybiotyków\nMetoda dyfuzyjna PB-216 wyd. II z dn. 23.10.2015 w oparciu o instrukcję producenta Premi Test Mieso, Ryby, Jaja Obecnosc pozostalosci antybiotykow\nMetoda dyfuzyjna PB-216 wyd. II z dn. 23.10.2015 w oparciu o instrukcje producenta Premi Test","categories":["food"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Gdynia","methodology_en":"Presence of antibiotic residues","search_en":"Meat, Fish, Eggs Presence of antibiotic residues Diffusion method Microbiology Laboratory Gdynia PB-216 wyd. II z dn. 23.10.2015 w oparciu o instrukcję producenta Premi Test","technique_en":"Diffusion method","test_object_en":"Meat, Fish, Eggs","search_zh":"扩散法 微生物实验室 Gdynia PB-216 wyd. II z dn. 23.10.2015 w oparciu o instrukcję producenta Premi Test","technique_zh":"扩散法","lab_section_zh":"微生物实验室 Gdynia"},{"_id":"6a7d76396040ebab2620d2e3","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Mleko, Mleko w proszku, Śmietanka","methodology":"Obecność antybiotyków i innych substancji hamujących","parameters":[],"technique":"Metoda dyfuzyjna","techniques":["Metoda dyfuzyjna"],"computed":[],"activity":"Obecność antybiotyków i innych substancji hamujących\nMetoda dyfuzyjna","reference":"PN-91/A-86033 test Delvotest SP NT","norm_bases":["PN-91/A-86033 test Delvotest SP NT"],"lab_section":"Pracownia Mikrobiologii Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko, Mleko w proszku, Śmietanka Obecność antybiotyków i innych substancji hamujących\nMetoda dyfuzyjna PN-91/A-86033 test Delvotest SP NT Mleko, Mleko w proszku, Smietanka Obecnosc antybiotykow i innych substancji hamujacych\nMetoda dyfuzyjna PN-91/A-86033 test Delvotest SP NT","categories":["food"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Gdynia","methodology_en":"Presence of antibiotics and other inhibitory substances","search_en":"Milk, Milk powder, Cream Presence of antibiotics and other inhibitory substances Diffusion method Microbiology Laboratory Gdynia PN-91/A-86033 test Delvotest SP NT","technique_en":"Diffusion method","test_object_en":"Milk, Milk powder, Cream","methodology_zh":"抗生素及其他抑菌物质的检出","search_zh":"抗生素及其他抑菌物质的检出 扩散法 微生物实验室 Gdynia PN-91/A-86033 test Delvotest SP NT","technique_zh":"扩散法","lab_section_zh":"微生物实验室 Gdynia"},{"_id":"6a7d76396040ebab2620d2e4","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Przetwory owocowe, warzywne i warzywno-mięsne","methodology":"Trwałość konserw","parameters":[],"technique":"Metoda termostatowa","techniques":["Metoda termostatowa"],"computed":[],"activity":"Trwałość konserw\nMetoda termostatowa","reference":"PN-90/A-75052/03","norm_bases":["PN-90/A-75052/03"],"lab_section":"Pracownia Mikrobiologii Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory owocowe, warzywne i warzywno-mięsne Trwałość konserw\nMetoda termostatowa PN-90/A-75052/03 Przetwory owocowe, warzywne i warzywno-miesne Trwalosc konserw\nMetoda termostatowa PN-90/A-75052/03","categories":["other"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Gdynia","methodology_en":"Shelf stability of canned products","search_en":"Fruit, vegetable and vegetable-meat preserves Shelf stability of canned products Thermostatic method Microbiology Laboratory Gdynia PN-90/A-75052/03","technique_en":"Thermostatic method","test_object_en":"Fruit, vegetable and vegetable-meat preserves","lab_section_zh":"微生物实验室 Gdynia","methodology_zh":"罐头保存性","search_zh":"水果、蔬菜与蔬菜肉类制品 罐头保存性 恒温培养法 微生物实验室 Gdynia PN-90/A-75052/03","technique_zh":"恒温培养法","test_object_zh":"水果、蔬菜与蔬菜肉类制品"},{"_id":"6a7d76396040ebab2620d2e5","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Mięso i produkty mięsne","methodology":"Trwałość konserw","parameters":[],"technique":"Metoda termostatowa","techniques":["Metoda termostatowa"],"computed":[],"activity":"Trwałość konserw\nMetoda termostatowa","reference":"PN-A-82055-5:1994","norm_bases":["PN-A-82055-5:1994"],"lab_section":"Pracownia Mikrobiologii Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i produkty mięsne Trwałość konserw\nMetoda termostatowa PN-A-82055-5:1994 Mieso i produkty miesne Trwalosc konserw\nMetoda termostatowa PN-A-82055-5:1994","categories":["food"],"row_index":110,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Gdynia","methodology_en":"Shelf stability of canned products","search_en":"Meat and meat products Shelf stability of canned products Thermostatic method Microbiology Laboratory Gdynia PN-A-82055-5:1994","technique_en":"Thermostatic method","test_object_en":"Meat and meat products","search_zh":"肉与肉制品 罐头保存性 恒温培养法 微生物实验室 Gdynia PN-A-82055-5:1994","test_object_zh":"肉与肉制品","lab_section_zh":"微生物实验室 Gdynia","methodology_zh":"罐头保存性","technique_zh":"恒温培养法"},{"_id":"6a7d76396040ebab2620d2e6","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Ryby i przetwory rybne","methodology":"Trwałość konserw","parameters":[],"technique":"Metoda termostatowa","techniques":["Metoda termostatowa"],"computed":[],"activity":"Trwałość konserw\nMetoda termostatowa","reference":"PN-A-86732:1992","norm_bases":["PN-A-86732:1992"],"lab_section":"Pracownia Mikrobiologii Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ryby i przetwory rybne Trwałość konserw\nMetoda termostatowa PN-A-86732:1992 Ryby i przetwory rybne Trwalosc konserw\nMetoda termostatowa PN-A-86732:1992","categories":["other"],"row_index":111,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Gdynia","methodology_en":"Shelf stability of canned products","search_en":"Fish and fish products Shelf stability of canned products Thermostatic method Microbiology Laboratory Gdynia PN-A-86732:1992","technique_en":"Thermostatic method","test_object_en":"Fish and fish products","search_zh":"鱼与鱼制品 罐头保存性 恒温培养法 微生物实验室 Gdynia PN-A-86732:1992","test_object_zh":"鱼与鱼制品","lab_section_zh":"微生物实验室 Gdynia","methodology_zh":"罐头保存性","technique_zh":"恒温培养法"},{"_id":"6a7d76396040ebab2620d2e7","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością i kosmetykami: - wymazy z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem","methodology":"Liczba bakterii z rodzaju Legionella","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii z rodzaju Legionella\nMetoda filtracji membranowej","reference":"PB-404 wyd. I z dn. 30.10.2019","norm_bases":["PB-404 wyd. I z dn. 30.10.2019"],"lab_section":"Pracownia Mikrobiologii Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością i kosmetykami: - wymazy z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem Liczba bakterii z rodzaju Legionella\nMetoda filtracji membranowej PB-404 wyd. I z dn. 30.10.2019 Probki srodowiskowe z obszarow produkcji zywnosci i kosmetykow oraz obrotu zywnoscia i kosmetykami: - wymazy z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem Liczba bakterii z rodzaju Legionella\nMetoda filtracji membranowej PB-404 wyd. I z dn. 30.10.2019","categories":["microbiology","food","environment","pharma"],"row_index":112,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Gdynia","methodology_en":"Count of bacteria of the genus Legionella","search_en":"Environmental samples from food and cosmetics production and distribution areas: - swabs from an area delimited by a template - swabs from an area not delimited by a template Count of bacteria of the genus Legionella Membrane filtration method Microbiology Laboratory Gdynia PB-404 wyd. I z dn. 30.10.2019","technique_en":"Membrane filtration method","test_object_en":"Environmental samples from food and cosmetics production and distribution areas: - swabs from an area delimited by a template - swabs from an area not delimited by a template","search_zh":"军团菌属细菌计数 膜过滤法 微生物实验室 Gdynia PB-404 wyd. I z dn. 30.10.2019","technique_zh":"膜过滤法","methodology_zh":"军团菌属细菌计数","lab_section_zh":"微生物实验室 Gdynia"},{"_id":"6a7d76396040ebab2620d2e8","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością i kosmetykami E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Gdynia","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością i kosmetykami E Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy) Normy Procedury badawcze Zywnosc E, Pasze dla zwierzat E, Probki srodowiskowe z obszarow produkcji zywnosci i kosmetykow oraz obrotu zywnoscia i kosmetykami E Liczba drobnoustrojow\nMetoda plytkowa (posiew powierzchniowy) Normy Procedury badawcze","categories":["food","environment","microbiology","pharma"],"row_index":113,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Gdynia","methodology_en":"Microorganism count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E, Environmental samples from areas of food and cosmetics production and food and cosmetics trade E Microorganism count Plate method (spread plate) Microbiology Laboratory Gdynia E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Plate method (spread plate)","test_object_en":"Food E, Animal feed E, Environmental samples from areas of food and cosmetics production and food and cosmetics trade E","methodology_zh":"菌落总数","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E、来自食品与化妆品生产及食品与化妆品流通场所的环境样品 E 菌落总数 平板法（表面涂布） 微生物实验室 Gdynia E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"平板法（表面涂布）","lab_section_zh":"微生物实验室 Gdynia","test_object_zh":"食品 E、动物饲料 E、来自食品与化妆品生产及食品与化妆品流通场所的环境样品 E"},{"_id":"6a7d76396040ebab2620d2e9","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji kosmetyków i obrotu kosmetykami E, Woda do spożycia przez ludzi, woda powierzchniowa, woda, woda na pływalniach E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Gdynia","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji kosmetyków i obrotu kosmetykami E, Woda do spożycia przez ludzi, woda powierzchniowa, woda, woda na pływalniach E Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Normy Procedury badawcze Zywnosc E, Pasze dla zwierzat E, Probki srodowiskowe z obszarow produkcji kosmetykow i obrotu kosmetykami E, Woda do spozycia przez ludzi, woda powierzchniowa, woda, woda na plywalniach E Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Normy Procedury badawcze","categories":["water","food","environment","microbiology","pharma"],"row_index":114,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Gdynia","methodology_en":"Microorganism count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E, Environmental samples from cosmetics production and cosmetics trade areas E, Water intended for human consumption, surface water, water, swimming pool water E Microorganism count Plate method (pour plate) Microbiology Laboratory Gdynia E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Plate method (pour plate)","test_object_en":"Food E, Animal feed E, Environmental samples from cosmetics production and cosmetics trade areas E, Water intended for human consumption, surface water, water, swimming pool water E","methodology_zh":"菌落总数","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"菌落总数 平板法（倾注培养） 微生物实验室 Gdynia E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"平板法（倾注培养）","lab_section_zh":"微生物实验室 Gdynia"},{"_id":"6a7d76396040ebab2620d2ea","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności oraz obrotu żywnością E, Papier, tektura, wyroby z papieru i tektury E, Wyroby z tworzyw sztucznych i wyroby z gumy E, Wyroby z metalu, szkła i ceramiki, Drewno i wyroby z drewna E - wymazy z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Mikrobiologii Gdynia","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności oraz obrotu żywnością E, Papier, tektura, wyroby z papieru i tektury E, Wyroby z tworzyw sztucznych i wyroby z gumy E, Wyroby z metalu, szkła i ceramiki, Drewno i wyroby z drewna E - wymazy z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Normy Probki srodowiskowe z obszarow produkcji zywnosci oraz obrotu zywnoscia E, Papier, tektura, wyroby z papieru i tektury E, Wyroby z tworzyw sztucznych i wyroby z gumy E, Wyroby z metalu, szkla i ceramiki, Drewno i wyroby z drewna E - wymazy z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Normy","categories":["materials","food","environment","microbiology"],"row_index":115,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Gdynia","methodology_en":"Microorganism count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Environmental samples from food production and food distribution areas E, Paper, board, paper and board products E, Plastics products and rubber products E, Metal, glass and ceramic products, Wood and wood products E - swabs from an area delimited by a template - swabs from an area not delimited by a template Microorganism count Plate method (pour plate) Microbiology Laboratory Gdynia E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy","technique_en":"Plate method (pour plate)","test_object_en":"Environmental samples from food production and food distribution areas E, Paper, board, paper and board products E, Plastics products and rubber products E, Metal, glass and ceramic products, Wood and wood products E - swabs from an area delimited by a template - swabs from an area not delimited by a template","methodology_zh":"菌落总数","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"菌落总数 平板法（倾注培养） 微生物实验室 Gdynia E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy","technique_zh":"平板法（倾注培养）","lab_section_zh":"微生物实验室 Gdynia"},{"_id":"6a7d76396040ebab2620d2eb","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością i kosmetykami E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa","techniques":["Metoda płytkowa"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Gdynia","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością i kosmetykami E Liczba drobnoustrojów\nMetoda płytkowa Normy Procedury badawcze Probki srodowiskowe z obszarow produkcji zywnosci i kosmetykow oraz obrotu zywnoscia i kosmetykami E Liczba drobnoustrojow\nMetoda plytkowa Normy Procedury badawcze","categories":["food","environment","microbiology","pharma"],"row_index":116,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Gdynia","methodology_en":"Microorganism count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Environmental samples from areas of food and cosmetics production and food and cosmetics trade E Microorganism count Plate method Microbiology Laboratory Gdynia E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Plate method","test_object_en":"Environmental samples from areas of food and cosmetics production and food and cosmetics trade E","methodology_zh":"菌落总数","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"来自食品与化妆品生产及食品与化妆品流通场所的环境样品 E 菌落总数 平板法 微生物实验室 Gdynia E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"平板法","lab_section_zh":"微生物实验室 Gdynia","test_object_zh":"来自食品与化妆品生产及食品与化妆品流通场所的环境样品 E"},{"_id":"6a7d76396040ebab2620d2ec","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością i kosmetykami E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana probówkowa","techniques":["Metoda hodowlana probówkowa"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana probówkowa","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Gdynia","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością i kosmetykami E Obecność drobnoustrojów\nMetoda hodowlana probówkowa Normy Procedury badawcze Zywnosc E, Pasze dla zwierzat E, Probki srodowiskowe z obszarow produkcji zywnosci i kosmetykow oraz obrotu zywnoscia i kosmetykami E Obecnosc drobnoustrojow\nMetoda hodowlana probowkowa Normy Procedury badawcze","categories":["food","environment","microbiology","pharma"],"row_index":117,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Gdynia","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E, Environmental samples from areas of food and cosmetics production and food and cosmetics trade E Presence of microorganisms Tube culture method Microbiology Laboratory Gdynia E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Tube culture method","test_object_en":"Food E, Animal feed E, Environmental samples from areas of food and cosmetics production and food and cosmetics trade E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E、来自食品与化妆品生产及食品与化妆品流通场所的环境样品 E 微生物的检出 试管培养法 微生物实验室 Gdynia E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","methodology_zh":"微生物的检出","lab_section_zh":"微生物实验室 Gdynia","technique_zh":"试管培养法","test_object_zh":"食品 E、动物饲料 E、来自食品与化妆品生产及食品与化妆品流通场所的环境样品 E"},{"_id":"6a7d76396040ebab2620d2ed","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością i kosmetykami E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana probówkowa z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana probówkowa z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana probówkowa z potwierdzeniem biochemicznym","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Gdynia","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością i kosmetykami E Obecność drobnoustrojów\nMetoda hodowlana probówkowa z potwierdzeniem biochemicznym Normy Procedury badawcze Zywnosc E, Pasze dla zwierzat E, Probki srodowiskowe z obszarow produkcji zywnosci i kosmetykow oraz obrotu zywnoscia i kosmetykami E Obecnosc drobnoustrojow\nMetoda hodowlana probowkowa z potwierdzeniem biochemicznym Normy Procedury badawcze","categories":["food","environment","microbiology","pharma"],"row_index":118,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Gdynia","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E, Environmental samples from areas of food and cosmetics production and food and cosmetics trade E Presence of microorganisms Tube culture method with biochemical confirmation Microbiology Laboratory Gdynia E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Tube culture method with biochemical confirmation","test_object_en":"Food E, Animal feed E, Environmental samples from areas of food and cosmetics production and food and cosmetics trade E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E、来自食品与化妆品生产及食品与化妆品流通场所的环境样品 E 微生物的检出 试管培养法（附生化确证） 微生物实验室 Gdynia E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","methodology_zh":"微生物的检出","lab_section_zh":"微生物实验室 Gdynia","technique_zh":"试管培养法（附生化确证）","test_object_zh":"食品 E、动物饲料 E、来自食品与化妆品生产及食品与化妆品流通场所的环境样品 E"},{"_id":"6a7d76396040ebab2620d2ee","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością i kosmetykami E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Gdynia","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością i kosmetykami E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym Normy Procedury badawcze Zywnosc E, Pasze dla zwierzat E, Probki srodowiskowe z obszarow produkcji zywnosci i kosmetykow oraz obrotu zywnoscia i kosmetykami E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym Normy Procedury badawcze","categories":["food","environment","microbiology","pharma"],"row_index":119,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Gdynia","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E, Environmental samples from areas of food and cosmetics production and food and cosmetics trade E Presence of microorganisms Culture method with biochemical confirmation Microbiology Laboratory Gdynia E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Culture method with biochemical confirmation","test_object_en":"Food E, Animal feed E, Environmental samples from areas of food and cosmetics production and food and cosmetics trade E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E、来自食品与化妆品生产及食品与化妆品流通场所的环境样品 E 微生物的检出 培养法结合生化确认 微生物实验室 Gdynia E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"培养法结合生化确认","methodology_zh":"微生物的检出","lab_section_zh":"微生物实验室 Gdynia","test_object_zh":"食品 E、动物饲料 E、来自食品与化妆品生产及食品与化妆品流通场所的环境样品 E"},{"_id":"6a7d76396040ebab2620d2ef","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E, Woda do spożycia przez ludzi, woda powierzchniowa, woda na pływalniach E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Gdynia","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E, Woda do spożycia przez ludzi, woda powierzchniowa, woda na pływalniach E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy Procedury badawcze Zywnosc E, Pasze dla zwierzat E, Woda do spozycia przez ludzi, woda powierzchniowa, woda na plywalniach E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy Procedury badawcze","categories":["water","food","microbiology"],"row_index":120,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Gdynia","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E, Water intended for human consumption, surface water, swimming pool water E Presence of microorganisms Culture method with biochemical and serological confirmation Microbiology Laboratory Gdynia E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Food E, Animal feed E, Water intended for human consumption, surface water, swimming pool water E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"微生物的检出 培养法结合生化与血清学确认 微生物实验室 Gdynia E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"培养法结合生化与血清学确认","methodology_zh":"微生物的检出","lab_section_zh":"微生物实验室 Gdynia"},{"_id":"6a7d76396040ebab2620d2f0","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności oraz obrotu żywnością E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Mikrobiologii Gdynia","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności oraz obrotu żywnością E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy Probki srodowiskowe z obszarow produkcji zywnosci oraz obrotu zywnoscia E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy","categories":["food","environment","microbiology"],"row_index":121,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Gdynia","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Environmental samples from food production and food trade areas E Presence of microorganisms Culture method with biochemical and serological confirmation Microbiology Laboratory Gdynia E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Environmental samples from food production and food trade areas E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"微生物的检出 培养法结合生化与血清学确认 微生物实验室 Gdynia E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy","technique_zh":"培养法结合生化与血清学确认","methodology_zh":"微生物的检出","lab_section_zh":"微生物实验室 Gdynia"},{"_id":"6a7d76396040ebab2620d2f1","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Mikrobiologii Gdynia","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym Normy Zywnosc E, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym Normy","categories":["food","environment","microbiology"],"row_index":122,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Gdynia","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Environmental samples from food production and food trade areas E Presence of microorganisms Culture method with biochemical and microscopic confirmation Microbiology Laboratory Gdynia E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy","technique_en":"Culture method with biochemical and microscopic confirmation","test_object_en":"Food E, Environmental samples from food production and food trade areas E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、来自食品生产与流通场所的环境样品 E 微生物的检出 培养法（附生化与显微确证） 微生物实验室 Gdynia E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy","methodology_zh":"微生物的检出","technique_zh":"培养法（附生化与显微确证）","lab_section_zh":"微生物实验室 Gdynia","test_object_zh":"食品 E、来自食品生产与流通场所的环境样品 E"},{"_id":"6a7d76396040ebab2620d2f2","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością i kosmetykami E","methodology":"Najbardziej prawdopodobna liczba drobnoustrojów","parameters":[],"technique":"Metoda NPL (probówkowa)","techniques":["Metoda NPL (probówkowa)"],"computed":[],"activity":"Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda NPL (probówkowa)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Gdynia","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością i kosmetykami E Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda NPL (probówkowa) Normy Procedury badawcze Zywnosc E, Pasze dla zwierzat E, Probki srodowiskowe z obszarow produkcji zywnosci i kosmetykow oraz obrotu zywnoscia i kosmetykami E Najbardziej prawdopodobna liczba drobnoustrojow\nMetoda NPL (probowkowa) Normy Procedury badawcze","categories":["food","environment","microbiology","pharma"],"row_index":123,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Gdynia","methodology_en":"Most probable number of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E, Environmental samples from areas of food and cosmetics production and food and cosmetics trade E Most probable number of microorganisms MPN method (tube) Microbiology Laboratory Gdynia E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"MPN method (tube)","test_object_en":"Food E, Animal feed E, Environmental samples from areas of food and cosmetics production and food and cosmetics trade E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E、来自食品与化妆品生产及食品与化妆品流通场所的环境样品 E 微生物最可能数 MPN 法（试管法） 微生物实验室 Gdynia E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","lab_section_zh":"微生物实验室 Gdynia","methodology_zh":"微生物最可能数","test_object_zh":"食品 E、动物饲料 E、来自食品与化妆品生产及食品与化妆品流通场所的环境样品 E","technique_zh":"MPN 法（试管法）"},{"_id":"6a7d76396040ebab2620d2f3","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Woda do spożycia przez ludzi, woda powierzchniowa, woda na pływalniach, woda E, Olej napędowy E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda filtracji membranowej","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Mikrobiologii Gdynia","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Woda do spożycia przez ludzi, woda powierzchniowa, woda na pływalniach, woda E, Olej napędowy E Liczba drobnoustrojów\nMetoda filtracji membranowej Normy Zywnosc E, Woda do spozycia przez ludzi, woda powierzchniowa, woda na plywalniach, woda E, Olej napedowy E Liczba drobnoustrojow\nMetoda filtracji membranowej Normy","categories":["water","petro","food","microbiology"],"row_index":124,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Gdynia","methodology_en":"Microorganism count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Water intended for human consumption, surface water, swimming pool water, water E, Diesel oil E Microorganism count Membrane filtration method Microbiology Laboratory Gdynia E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy","technique_en":"Membrane filtration method","test_object_en":"Food E, Water intended for human consumption, surface water, swimming pool water, water E, Diesel oil E","methodology_zh":"菌落总数","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"菌落总数 膜过滤法 微生物实验室 Gdynia E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy","technique_zh":"膜过滤法","lab_section_zh":"微生物实验室 Gdynia"},{"_id":"6a7d76396040ebab2620d2f4","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Papier, tektura, wyroby z papieru i tektury E, Wyroby z tworzyw sztucznych i wyroby z gumy E, Wyroby z metalu, szkła i ceramiki E, Drewno i wyroby z drewna E - wymazy z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana probówkowa z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana probówkowa z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana probówkowa z potwierdzeniem biochemicznym","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Mikrobiologii Gdynia","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Papier, tektura, wyroby z papieru i tektury E, Wyroby z tworzyw sztucznych i wyroby z gumy E, Wyroby z metalu, szkła i ceramiki E, Drewno i wyroby z drewna E - wymazy z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem Obecność drobnoustrojów\nMetoda hodowlana probówkowa z potwierdzeniem biochemicznym Normy Papier, tektura, wyroby z papieru i tektury E, Wyroby z tworzyw sztucznych i wyroby z gumy E, Wyroby z metalu, szkla i ceramiki E, Drewno i wyroby z drewna E - wymazy z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem Obecnosc drobnoustrojow\nMetoda hodowlana probowkowa z potwierdzeniem biochemicznym Normy","categories":["materials","microbiology"],"row_index":125,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Gdynia","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Paper, board, paper and board products E, Plastic products and rubber products E, Metal, glass and ceramic products E, Wood and wood products E - swabs from a template-delimited surface - swabs from a surface not delimited by a template Presence of microorganisms Tube culture method with biochemical confirmation Microbiology Laboratory Gdynia E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy","technique_en":"Tube culture method with biochemical confirmation","test_object_en":"Paper, board, paper and board products E, Plastic products and rubber products E, Metal, glass and ceramic products E, Wood and wood products E - swabs from a template-delimited surface - swabs from a surface not delimited by a template","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"纸、纸板、纸与纸板制品 E，塑料制品与橡胶制品 E，金属、玻璃与陶瓷制品 E，木材与木制品 E － 用模板限定面积的涂抹样 － 未用模板限定面积的涂抹样 微生物的检出 试管培养法（附生化确证） 微生物实验室 Gdynia E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy","methodology_zh":"微生物的检出","lab_section_zh":"微生物实验室 Gdynia","technique_zh":"试管培养法（附生化确证）","test_object_zh":"纸、纸板、纸与纸板制品 E，塑料制品与橡胶制品 E，金属、玻璃与陶瓷制品 E，木材与木制品 E － 用模板限定面积的涂抹样 － 未用模板限定面积的涂抹样"},{"_id":"6a7d76396040ebab2620d2f5","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Papier, tektura, wyroby z papieru i tektury E, Wyroby z tworzyw sztucznych i wyroby z gumy E, Wyroby z metalu, szkła i ceramiki E, Drewno i wyroby z drewna E - wymazy z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Mikrobiologii Gdynia","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Papier, tektura, wyroby z papieru i tektury E, Wyroby z tworzyw sztucznych i wyroby z gumy E, Wyroby z metalu, szkła i ceramiki E, Drewno i wyroby z drewna E - wymazy z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym Normy Papier, tektura, wyroby z papieru i tektury E, Wyroby z tworzyw sztucznych i wyroby z gumy E, Wyroby z metalu, szkla i ceramiki E, Drewno i wyroby z drewna E - wymazy z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym Normy","categories":["materials","microbiology"],"row_index":126,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Gdynia","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Paper, board, paper and board products E, Plastic products and rubber products E, Metal, glass and ceramic products E, Wood and wood products E - swabs from a template-delimited surface - swabs from a surface not delimited by a template Presence of microorganisms Culture method with biochemical confirmation Microbiology Laboratory Gdynia E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy","technique_en":"Culture method with biochemical confirmation","test_object_en":"Paper, board, paper and board products E, Plastic products and rubber products E, Metal, glass and ceramic products E, Wood and wood products E - swabs from a template-delimited surface - swabs from a surface not delimited by a template","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"纸、纸板、纸与纸板制品 E，塑料制品与橡胶制品 E，金属、玻璃与陶瓷制品 E，木材与木制品 E － 用模板限定面积的涂抹样 － 未用模板限定面积的涂抹样 微生物的检出 培养法结合生化确认 微生物实验室 Gdynia E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy","technique_zh":"培养法结合生化确认","methodology_zh":"微生物的检出","lab_section_zh":"微生物实验室 Gdynia","test_object_zh":"纸、纸板、纸与纸板制品 E，塑料制品与橡胶制品 E，金属、玻璃与陶瓷制品 E，木材与木制品 E － 用模板限定面积的涂抹样 － 未用模板限定面积的涂抹样"},{"_id":"6a7d76396040ebab2620d2f6","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Papier, tektura, wyroby z papieru i tektury E, Wyroby z tworzyw sztucznych i wyroby z gumy E, Wyroby z metalu, szkła i ceramiki E, Drewno i wyroby z drewna E - wymazy z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Mikrobiologii Gdynia","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Papier, tektura, wyroby z papieru i tektury E, Wyroby z tworzyw sztucznych i wyroby z gumy E, Wyroby z metalu, szkła i ceramiki E, Drewno i wyroby z drewna E - wymazy z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy Papier, tektura, wyroby z papieru i tektury E, Wyroby z tworzyw sztucznych i wyroby z gumy E, Wyroby z metalu, szkla i ceramiki E, Drewno i wyroby z drewna E - wymazy z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy","categories":["materials","microbiology"],"row_index":127,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Gdynia","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Paper, board, paper and board products E, Plastic products and rubber products E, Metal, glass and ceramic products E, Wood and wood products E - swabs from a template-delimited surface - swabs from a surface not delimited by a template Presence of microorganisms Culture method with biochemical and serological confirmation Microbiology Laboratory Gdynia E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Paper, board, paper and board products E, Plastic products and rubber products E, Metal, glass and ceramic products E, Wood and wood products E - swabs from a template-delimited surface - swabs from a surface not delimited by a template","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"纸、纸板、纸与纸板制品 E，塑料制品与橡胶制品 E，金属、玻璃与陶瓷制品 E，木材与木制品 E － 用模板限定面积的涂抹样 － 未用模板限定面积的涂抹样 微生物的检出 培养法结合生化与血清学确认 微生物实验室 Gdynia E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy","technique_zh":"培养法结合生化与血清学确认","methodology_zh":"微生物的检出","lab_section_zh":"微生物实验室 Gdynia","test_object_zh":"纸、纸板、纸与纸板制品 E，塑料制品与橡胶制品 E，金属、玻璃与陶瓷制品 E，木材与木制品 E － 用模板限定面积的涂抹样 － 未用模板限定面积的涂抹样"},{"_id":"6a7d76396040ebab2620d2f7","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Szczepy drobnoustrojów E","methodology":"Identyfikacja taksonomiczna drobnoustrojów","parameters":[],"technique":"Metoda biochemiczna, immunochemiczna, PCR, mikroskopowa","techniques":["Metoda biochemiczna, immunochemiczna, PCR, mikroskopowa"],"computed":[],"activity":"Identyfikacja taksonomiczna drobnoustrojów\nMetoda biochemiczna, immunochemiczna, PCR, mikroskopowa","reference":"PB-251","norm_bases":["PB-251"],"lab_section":"Pracownia Mikrobiologii Gdynia","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Szczepy drobnoustrojów E Identyfikacja taksonomiczna drobnoustrojów\nMetoda biochemiczna, immunochemiczna, PCR, mikroskopowa PB-251 Szczepy drobnoustrojow E Identyfikacja taksonomiczna drobnoustrojow\nMetoda biochemiczna, immunochemiczna, PCR, mikroskopowa PB-251","categories":["microbiology"],"row_index":128,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Gdynia","methodology_en":"Taxonomic identification of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Microbial strains E Taxonomic identification of microorganisms Biochemical, immunochemical, PCR, microscopic method Microbiology Laboratory Gdynia E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. PB-251","technique_en":"Biochemical, immunochemical, PCR, microscopic method","test_object_en":"Microbial strains E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"微生物实验室 Gdynia E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 PB-251","lab_section_zh":"微生物实验室 Gdynia"},{"_id":"6a7d76396040ebab2620d2f8","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność specyficznego DNA, Escherichia coli oraz obecność, Escherichia coli wytwarzających toksyny Shiga (STEC)","parameters":[],"technique":"Metoda PCR, System Bax","techniques":["Metoda PCR, System Bax"],"computed":[],"activity":"Obecność specyficznego DNA, Escherichia coli oraz obecność, Escherichia coli wytwarzających toksyny Shiga (STEC)\nMetoda PCR, System Bax","reference":"ISO/TS 13136 | PB-402","norm_bases":["ISO/TS 13136","PB-402"],"lab_section":"Pracownia Mikrobiologii Gdynia","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Obecność specyficznego DNA, Escherichia coli oraz obecność, Escherichia coli wytwarzających toksyny Shiga (STEC)\nMetoda PCR, System Bax ISO/TS 13136 | PB-402 Zywnosc E Obecnosc specyficznego DNA, Escherichia coli oraz obecnosc, Escherichia coli wytwarzajacych toksyny Shiga (STEC)\nMetoda PCR, System Bax ISO/TS 13136 | PB-402","categories":["food","microbiology"],"row_index":129,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Gdynia","methodology_en":"Presence of DNA specific for, Escherichia coli and presence of, Escherichia coli producing Shiga toxins (STEC)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E Presence of DNA specific for, Escherichia coli and presence of, Escherichia coli producing Shiga toxins (STEC) PCR method, Bax System Microbiology Laboratory Gdynia E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. ISO/TS 13136 | PB-402","technique_en":"PCR method, Bax System","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E 微生物实验室 Gdynia E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 ISO/TS 13136 | PB-402","test_object_zh":"食品 E","lab_section_zh":"微生物实验室 Gdynia"},{"_id":"6a7d76396040ebab2620d2f9","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością i kosmetykami E","methodology":"Obecność specyficznego DNA dla drobnoustroju","parameters":[],"technique":"Metoda PCR, System Bax","techniques":["Metoda PCR, System Bax"],"computed":[],"activity":"Obecność specyficznego DNA dla drobnoustroju\nMetoda PCR, System Bax","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Gdynia","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością i kosmetykami E Obecność specyficznego DNA dla drobnoustroju\nMetoda PCR, System Bax Procedury badawcze Zywnosc E, Pasze dla zwierzat E, Probki srodowiskowe z obszarow produkcji zywnosci i kosmetykow oraz obrotu zywnoscia i kosmetykami E Obecnosc specyficznego DNA dla drobnoustroju\nMetoda PCR, System Bax Procedury badawcze","categories":["food","environment","microbiology","pharma"],"row_index":130,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Gdynia","methodology_en":"Presence of DNA specific for the microorganism","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E, Environmental samples from areas of food and cosmetics production and food and cosmetics trade E Presence of DNA specific for the microorganism PCR method, Bax System Microbiology Laboratory Gdynia E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Procedury badawcze","technique_en":"PCR method, Bax System","test_object_en":"Food E, Animal feed E, Environmental samples from areas of food and cosmetics production and food and cosmetics trade E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E、来自食品与化妆品生产及食品与化妆品流通场所的环境样品 E 微生物实验室 Gdynia E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Procedury badawcze","lab_section_zh":"微生物实验室 Gdynia","test_object_zh":"食品 E、动物饲料 E、来自食品与化妆品生产及食品与化妆品流通场所的环境样品 E"},{"_id":"6a7d76396040ebab2620d2fa","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E","methodology":"Obecność specyficznej sekwencji dla, GMO (screening)","parameters":[],"technique":"Metoda real-time PCR","techniques":["Metoda real-time PCR"],"computed":[],"activity":"Obecność specyficznej sekwencji dla, GMO (screening)\nMetoda real-time PCR","reference":"PB-397","norm_bases":["PB-397"],"lab_section":"Pracownia Biologii Molekularnej Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E Obecność specyficznej sekwencji dla, GMO (screening)\nMetoda real-time PCR PB-397 Zywnosc E, Pasze dla zwierzat E, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia E Obecnosc specyficznej sekwencji dla, GMO (screening)\nMetoda real-time PCR PB-397","categories":["food","environment"],"row_index":131,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Molecular Biology Laboratory Tychy","methodology_en":"Presence of sequence specific for, GMO (screening)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E Presence of sequence specific for, GMO (screening) Real-time PCR method Molecular Biology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. PB-397","technique_en":"Real-time PCR method","test_object_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E、来自食品生产与流通场所的环境样品 E 实时荧光 PCR 法 蒂黑分子生物学检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 PB-397","technique_zh":"实时荧光 PCR 法","test_object_zh":"食品 E、动物饲料 E、来自食品生产与流通场所的环境样品 E","lab_section_zh":"蒂黑分子生物学检验室"},{"_id":"6a7d76396040ebab2620d2fb","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E","methodology":"Obecność specyficznego DNA modyfikacji genetycznych","parameters":[],"technique":"Metoda real-time PCR","techniques":["Metoda real-time PCR"],"computed":[],"activity":"Obecność specyficznego DNA modyfikacji genetycznych\nMetoda real-time PCR","reference":"PB-391","norm_bases":["PB-391"],"lab_section":"Pracownia Biologii Molekularnej Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E Obecność specyficznego DNA modyfikacji genetycznych\nMetoda real-time PCR PB-391 Zywnosc E, Pasze dla zwierzat E, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia E Obecnosc specyficznego DNA modyfikacji genetycznych\nMetoda real-time PCR PB-391","categories":["food","environment"],"row_index":132,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Molecular Biology Laboratory Tychy","methodology_en":"Presence of DNA specific for genetic modifications","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E Presence of DNA specific for genetic modifications Real-time PCR method Molecular Biology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. PB-391","technique_en":"Real-time PCR method","test_object_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E、来自食品生产与流通场所的环境样品 E 实时荧光 PCR 法 蒂黑分子生物学检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 PB-391","technique_zh":"实时荧光 PCR 法","test_object_zh":"食品 E、动物饲料 E、来自食品生产与流通场所的环境样品 E","lab_section_zh":"蒂黑分子生物学检验室"},{"_id":"6a7d76396040ebab2620d2fc","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E","methodology":"Obecność specyficznego DNA alergenu","parameters":[],"technique":"Metoda real-time PCR","techniques":["Metoda real-time PCR"],"computed":[],"activity":"Obecność specyficznego DNA alergenu\nMetoda real-time PCR","reference":"PB-393 | PB-399","norm_bases":["PB-393","PB-399"],"lab_section":"Pracownia Biologii Molekularnej Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E Obecność specyficznego DNA alergenu\nMetoda real-time PCR PB-393 | PB-399 Zywnosc E, Pasze dla zwierzat E, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia E Obecnosc specyficznego DNA alergenu\nMetoda real-time PCR PB-393 | PB-399","categories":["food","environment"],"row_index":133,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Molecular Biology Laboratory Tychy","methodology_en":"Presence of allergen-specific DNA","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E Presence of allergen-specific DNA Real-time PCR method Molecular Biology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. PB-393 | PB-399","technique_en":"Real-time PCR method","test_object_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E、来自食品生产与流通场所的环境样品 E 实时荧光 PCR 法 蒂黑分子生物学检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 PB-393 | PB-399","technique_zh":"实时荧光 PCR 法","test_object_zh":"食品 E、动物饲料 E、来自食品生产与流通场所的环境样品 E","lab_section_zh":"蒂黑分子生物学检验室"},{"_id":"6a7d76396040ebab2620d2fd","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E","methodology":"Obecność specyficznego DNA gatunków zwierząt","parameters":[],"technique":"Metoda real-time PCR","techniques":["Metoda real-time PCR"],"computed":[],"activity":"Obecność specyficznego DNA gatunków zwierząt\nMetoda real-time PCR","reference":"PB-399","norm_bases":["PB-399"],"lab_section":"Pracownia Biologii Molekularnej Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E Obecność specyficznego DNA gatunków zwierząt\nMetoda real-time PCR PB-399 Zywnosc E, Pasze dla zwierzat E, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia E Obecnosc specyficznego DNA gatunkow zwierzat\nMetoda real-time PCR PB-399","categories":["food","environment"],"row_index":134,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Molecular Biology Laboratory Tychy","methodology_en":"Presence of animal species-specific DNA","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E Presence of animal species-specific DNA Real-time PCR method Molecular Biology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. PB-399","technique_en":"Real-time PCR method","test_object_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E、来自食品生产与流通场所的环境样品 E 实时荧光 PCR 法 蒂黑分子生物学检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 PB-399","technique_zh":"实时荧光 PCR 法","test_object_zh":"食品 E、动物饲料 E、来自食品生产与流通场所的环境样品 E","lab_section_zh":"蒂黑分子生物学检验室"},{"_id":"6a7d76396040ebab2620d2fe","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E","methodology":"Zawartość alergenu","parameters":[],"technique":"Metoda immunoenzymatyczna - ELISA","techniques":["Metoda immunoenzymatyczna - ELISA"],"computed":[],"activity":"Zawartość alergenu\nMetoda immunoenzymatyczna - ELISA","reference":"PB-394","norm_bases":["PB-394"],"lab_section":"Pracownia Biologii Molekularnej Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E Zawartość alergenu\nMetoda immunoenzymatyczna - ELISA PB-394 Zywnosc E, Pasze dla zwierzat E, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia E Zawartosc alergenu\nMetoda immunoenzymatyczna - ELISA PB-394","categories":["food","environment"],"row_index":135,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Molecular Biology Laboratory Tychy","methodology_en":"Allergen content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E Allergen content Enzyme immunoassay method - ELISA Molecular Biology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. PB-394","technique_en":"Enzyme immunoassay method - ELISA","test_object_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E、来自食品生产与流通场所的环境样品 E 蒂黑分子生物学检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 PB-394","test_object_zh":"食品 E、动物饲料 E、来自食品生产与流通场所的环境样品 E","lab_section_zh":"蒂黑分子生物学检验室"},{"_id":"6a7d76396040ebab2620d2ff","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Owoce, warzywa i przetwory owocowe i warzywne E","methodology":"Obecność materiału genetycznego wirusów","parameters":[],"technique":"Metoda real-time RT-PCR","techniques":["Metoda real-time RT-PCR"],"computed":[],"activity":"Obecność materiału genetycznego wirusów\nMetoda real-time RT-PCR","reference":"PB-202","norm_bases":["PB-202"],"lab_section":"Pracownia Biologii Molekularnej Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Owoce, warzywa i przetwory owocowe i warzywne E Obecność materiału genetycznego wirusów\nMetoda real-time RT-PCR PB-202 Owoce, warzywa i przetwory owocowe i warzywne E Obecnosc materialu genetycznego wirusow\nMetoda real-time RT-PCR PB-202","categories":["materials"],"row_index":136,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Molecular Biology Laboratory Tychy","methodology_en":"Presence of viral genetic material","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Fruit, vegetables and fruit and vegetable products E Presence of viral genetic material Real-time RT-PCR method Molecular Biology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. PB-202","technique_en":"Real-time RT-PCR method","test_object_en":"Fruit, vegetables and fruit and vegetable products E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"病毒遗传物质的检出 实时荧光定量 RT-PCR 法 蒂黑分子生物学检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 PB-202","lab_section_zh":"蒂黑分子生物学检验室","methodology_zh":"病毒遗传物质的检出","technique_zh":"实时荧光定量 RT-PCR 法"},{"_id":"6a7d76396040ebab2620d300","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E","methodology":"Zawartość specyficznego DNA modyfikacji genetycznych","parameters":[],"technique":"Metoda real-time PCR","techniques":["Metoda real-time PCR"],"computed":[],"activity":"Zawartość specyficznego DNA modyfikacji genetycznych\nMetoda real-time PCR","reference":"PB-392","norm_bases":["PB-392"],"lab_section":"Pracownia Biologii Molekularnej Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E Zawartość specyficznego DNA modyfikacji genetycznych\nMetoda real-time PCR PB-392 Zywnosc E, Pasze dla zwierzat E Zawartosc specyficznego DNA modyfikacji genetycznych\nMetoda real-time PCR PB-392","categories":["food"],"row_index":137,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Molecular Biology Laboratory Tychy","methodology_en":"Content of DNA specific for genetic modifications","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E Content of DNA specific for genetic modifications Real-time PCR method Molecular Biology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. PB-392","technique_en":"Real-time PCR method","test_object_en":"Food E, Animal feed E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E 实时荧光 PCR 法 蒂黑分子生物学检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 PB-392","technique_zh":"实时荧光 PCR 法","lab_section_zh":"蒂黑分子生物学检验室","test_object_zh":"食品 E、动物饲料 E"},{"_id":"6a7d76396040ebab2620d301","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E","methodology":"Zawartość specyficznego DNA gatunków zwierząt","parameters":[],"technique":"Metoda real-time PCR","techniques":["Metoda real-time PCR"],"computed":[],"activity":"Zawartość specyficznego DNA gatunków zwierząt\nMetoda real-time PCR","reference":"PB-399","norm_bases":["PB-399"],"lab_section":"Pracownia Biologii Molekularnej Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E Zawartość specyficznego DNA gatunków zwierząt\nMetoda real-time PCR PB-399 Zywnosc E, Pasze dla zwierzat E Zawartosc specyficznego DNA gatunkow zwierzat\nMetoda real-time PCR PB-399","categories":["food"],"row_index":138,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Molecular Biology Laboratory Tychy","methodology_en":"Content of animal species-specific DNA","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E Content of animal species-specific DNA Real-time PCR method Molecular Biology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. PB-399","technique_en":"Real-time PCR method","test_object_en":"Food E, Animal feed E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E 实时荧光 PCR 法 蒂黑分子生物学检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 PB-399","technique_zh":"实时荧光 PCR 法","lab_section_zh":"蒂黑分子生物学检验室","test_object_zh":"食品 E、动物饲料 E"},{"_id":"6a7d76396040ebab2620d302","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E","methodology":"Zawartość specyficznego DNA alergenu","parameters":[],"technique":"Metoda real-time PCR","techniques":["Metoda real-time PCR"],"computed":[],"activity":"Zawartość specyficznego DNA alergenu\nMetoda real-time PCR","reference":"PB-399","norm_bases":["PB-399"],"lab_section":"Pracownia Biologii Molekularnej Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E Zawartość specyficznego DNA alergenu\nMetoda real-time PCR PB-399 Zywnosc E, Pasze dla zwierzat E Zawartosc specyficznego DNA alergenu\nMetoda real-time PCR PB-399","categories":["food"],"row_index":139,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Molecular Biology Laboratory Tychy","methodology_en":"Content of allergen-specific DNA","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E Content of allergen-specific DNA Real-time PCR method Molecular Biology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. PB-399","technique_en":"Real-time PCR method","test_object_en":"Food E, Animal feed E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E 实时荧光 PCR 法 蒂黑分子生物学检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 PB-399","technique_zh":"实时荧光 PCR 法","lab_section_zh":"蒂黑分子生物学检验室","test_object_zh":"食品 E、动物饲料 E"},{"_id":"6a7d76396040ebab2620d303","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji kosmetyków i obrotu kosmetykami: - wymaz z powierzchni ograniczonej szablonem - wymaz z powierzchni nieograniczonej szablonem","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 4833-1:2013-12","norm_bases":["PN-EN ISO 4833-1:2013-12"],"lab_section":"Pracownia Mikrobiologii Przeźmierowo","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji kosmetyków i obrotu kosmetykami: - wymaz z powierzchni ograniczonej szablonem - wymaz z powierzchni nieograniczonej szablonem Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 4833-1:2013-12 Probki srodowiskowe z obszarow produkcji kosmetykow i obrotu kosmetykami: - wymaz z powierzchni ograniczonej szablonem - wymaz z powierzchni nieograniczonej szablonem Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) PN-EN ISO 4833-1:2013-12","categories":["environment","microbiology","pharma"],"row_index":140,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Przeźmierowo","methodology_en":"Microorganism count","search_en":"Environmental samples from cosmetics production and cosmetics trade areas: - swab from a template-delimited surface - swab from a surface not delimited by a template Microorganism count Plate method (pour plate) Microbiology Laboratory Przeźmierowo PN-EN ISO 4833-1:2013-12","technique_en":"Plate method (pour plate)","test_object_en":"Environmental samples from cosmetics production and cosmetics trade areas: - swab from a template-delimited surface - swab from a surface not delimited by a template","methodology_zh":"菌落总数","search_zh":"菌落总数 平板法（倾注培养） 普热兹米耶罗沃微生物检验室 PN-EN ISO 4833-1:2013-12","technique_zh":"平板法（倾注培养）","lab_section_zh":"普热兹米耶罗沃微生物检验室"},{"_id":"6a7d76396040ebab2620d304","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji kosmetyków i obrotu kosmetykami: - wymaz z powierzchni ograniczonej szablonem - wymaz z powierzchni nieograniczonej szablonem","methodology":"Liczba Enterobacteriaceae","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba Enterobacteriaceae\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 21528-2:2017-08","norm_bases":["PN-ISO 21528-2:2017-08"],"lab_section":"Pracownia Mikrobiologii Przeźmierowo","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji kosmetyków i obrotu kosmetykami: - wymaz z powierzchni ograniczonej szablonem - wymaz z powierzchni nieograniczonej szablonem Liczba Enterobacteriaceae\nMetoda płytkowa (posiew wgłębny) PN-ISO 21528-2:2017-08 Probki srodowiskowe z obszarow produkcji kosmetykow i obrotu kosmetykami: - wymaz z powierzchni ograniczonej szablonem - wymaz z powierzchni nieograniczonej szablonem Liczba Enterobacteriaceae\nMetoda plytkowa (posiew wglebny) PN-ISO 21528-2:2017-08","categories":["environment","pharma"],"row_index":141,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Przeźmierowo","methodology_en":"Enterobacteriaceae count","search_en":"Environmental samples from cosmetics production and cosmetics trade areas: - swab from a template-delimited surface - swab from a surface not delimited by a template Enterobacteriaceae count Plate method (pour plate) Microbiology Laboratory Przeźmierowo PN-ISO 21528-2:2017-08","technique_en":"Plate method (pour plate)","test_object_en":"Environmental samples from cosmetics production and cosmetics trade areas: - swab from a template-delimited surface - swab from a surface not delimited by a template","methodology_zh":"肠杆菌科（Enterobacteriaceae）计数","search_zh":"肠杆菌科（Enterobacteriaceae）计数 平板法（倾注培养） 普热兹米耶罗沃微生物检验室 PN-ISO 21528-2:2017-08","technique_zh":"平板法（倾注培养）","lab_section_zh":"普热兹米耶罗沃微生物检验室"},{"_id":"6a7d76396040ebab2620d305","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji kosmetyków i obrotu kosmetykami - płytki kontaktowe (powierzchnie)","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa","techniques":["Metoda płytkowa"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa","reference":"PN-EN ISO 4833-2:2013-12","norm_bases":["PN-EN ISO 4833-2:2013-12"],"lab_section":"Pracownia Mikrobiologii Przeźmierowo","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji kosmetyków i obrotu kosmetykami - płytki kontaktowe (powierzchnie) Liczba drobnoustrojów\nMetoda płytkowa PN-EN ISO 4833-2:2013-12 Probki srodowiskowe z obszarow produkcji kosmetykow i obrotu kosmetykami - plytki kontaktowe (powierzchnie) Liczba drobnoustrojow\nMetoda plytkowa PN-EN ISO 4833-2:2013-12","categories":["environment","microbiology","pharma"],"row_index":142,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Przeźmierowo","methodology_en":"Microorganism count","search_en":"Environmental samples from cosmetics production and cosmetics trade areas - contact plates (surfaces) Microorganism count Plate method Microbiology Laboratory Przeźmierowo PN-EN ISO 4833-2:2013-12","technique_en":"Plate method","test_object_en":"Environmental samples from cosmetics production and cosmetics trade areas - contact plates (surfaces)","methodology_zh":"菌落总数","search_zh":"菌落总数 平板法 普热兹米耶罗沃微生物检验室 PN-EN ISO 4833-2:2013-12","technique_zh":"平板法","lab_section_zh":"普热兹米耶罗沃微生物检验室"},{"_id":"6a7d76396040ebab2620d306","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji kosmetyków i obrotu kosmetykami - płytki kontaktowe (powierzchnie)","methodology":"Liczba Enterobacteriaceae","parameters":[],"technique":"Metoda płytkowa","techniques":["Metoda płytkowa"],"computed":[],"activity":"Liczba Enterobacteriaceae\nMetoda płytkowa","reference":"PN-EN ISO 21528-2:2017-08","norm_bases":["PN-EN ISO 21528-2:2017-08"],"lab_section":"Pracownia Mikrobiologii Przeźmierowo","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji kosmetyków i obrotu kosmetykami - płytki kontaktowe (powierzchnie) Liczba Enterobacteriaceae\nMetoda płytkowa PN-EN ISO 21528-2:2017-08 Probki srodowiskowe z obszarow produkcji kosmetykow i obrotu kosmetykami - plytki kontaktowe (powierzchnie) Liczba Enterobacteriaceae\nMetoda plytkowa PN-EN ISO 21528-2:2017-08","categories":["environment","pharma"],"row_index":143,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Przeźmierowo","methodology_en":"Enterobacteriaceae count","search_en":"Environmental samples from cosmetics production and cosmetics trade areas - contact plates (surfaces) Enterobacteriaceae count Plate method Microbiology Laboratory Przeźmierowo PN-EN ISO 21528-2:2017-08","technique_en":"Plate method","test_object_en":"Environmental samples from cosmetics production and cosmetics trade areas - contact plates (surfaces)","methodology_zh":"肠杆菌科（Enterobacteriaceae）计数","search_zh":"肠杆菌科（Enterobacteriaceae）计数 平板法 普热兹米耶罗沃微生物检验室 PN-EN ISO 21528-2:2017-08","technique_zh":"平板法","lab_section_zh":"普热兹米耶罗沃微生物检验室"},{"_id":"6a7d76396040ebab2620d307","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Przeźmierowo","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy) Normy Procedury badawcze Zywnosc E, Pasze dla zwierzat E, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia E Liczba drobnoustrojow\nMetoda plytkowa (posiew powierzchniowy) Normy Procedury badawcze","categories":["food","environment","microbiology"],"row_index":144,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Przeźmierowo","methodology_en":"Microorganism count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E Microorganism count Plate method (spread plate) Microbiology Laboratory Przeźmierowo E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Plate method (spread plate)","test_object_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E","methodology_zh":"菌落总数","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E、来自食品生产与流通场所的环境样品 E 菌落总数 平板法（表面涂布） 普热兹米耶罗沃微生物检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"平板法（表面涂布）","lab_section_zh":"普热兹米耶罗沃微生物检验室","test_object_zh":"食品 E、动物饲料 E、来自食品生产与流通场所的环境样品 E"},{"_id":"6a7d76396040ebab2620d308","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana probówkowa","techniques":["Metoda hodowlana probówkowa"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana probówkowa","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Przeźmierowo","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E Obecność drobnoustrojów\nMetoda hodowlana probówkowa Normy Procedury badawcze Zywnosc E, Pasze dla zwierzat E, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia E Obecnosc drobnoustrojow\nMetoda hodowlana probowkowa Normy Procedury badawcze","categories":["food","environment","microbiology"],"row_index":145,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Przeźmierowo","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E Presence of microorganisms Tube culture method Microbiology Laboratory Przeźmierowo E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Tube culture method","test_object_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E、来自食品生产与流通场所的环境样品 E 微生物的检出 试管培养法 普热兹米耶罗沃微生物检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","methodology_zh":"微生物的检出","technique_zh":"试管培养法","lab_section_zh":"普热兹米耶罗沃微生物检验室","test_object_zh":"食品 E、动物饲料 E、来自食品生产与流通场所的环境样品 E"},{"_id":"6a7d76396040ebab2620d309","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana probówkowa z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana probówkowa z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana probówkowa z potwierdzeniem biochemicznym","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Mikrobiologii Przeźmierowo","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E Obecność drobnoustrojów\nMetoda hodowlana probówkowa z potwierdzeniem biochemicznym Normy Zywnosc E, Pasze dla zwierzat E, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia E Obecnosc drobnoustrojow\nMetoda hodowlana probowkowa z potwierdzeniem biochemicznym Normy","categories":["food","environment","microbiology"],"row_index":146,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Przeźmierowo","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E Presence of microorganisms Tube culture method with biochemical confirmation Microbiology Laboratory Przeźmierowo E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy","technique_en":"Tube culture method with biochemical confirmation","test_object_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E、来自食品生产与流通场所的环境样品 E 微生物的检出 试管培养法（附生化确证） 普热兹米耶罗沃微生物检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy","methodology_zh":"微生物的检出","lab_section_zh":"普热兹米耶罗沃微生物检验室","test_object_zh":"食品 E、动物饲料 E、来自食品生产与流通场所的环境样品 E","technique_zh":"试管培养法（附生化确证）"},{"_id":"6a7d76396040ebab2620d30a","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Przeźmierowo","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym Normy Procedury badawcze Zywnosc E, Pasze dla zwierzat E, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym Normy Procedury badawcze","categories":["food","environment","microbiology"],"row_index":147,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Przeźmierowo","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E Presence of microorganisms Culture method with biochemical confirmation Microbiology Laboratory Przeźmierowo E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Culture method with biochemical confirmation","test_object_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E、来自食品生产与流通场所的环境样品 E 微生物的检出 培养法结合生化确认 普热兹米耶罗沃微生物检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"培养法结合生化确认","methodology_zh":"微生物的检出","lab_section_zh":"普热兹米耶罗沃微生物检验室","test_object_zh":"食品 E、动物饲料 E、来自食品生产与流通场所的环境样品 E"},{"_id":"6a7d76396040ebab2620d30b","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Mikrobiologii Przeźmierowo","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym Normy Zywnosc E, Pasze dla zwierzat E, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym Normy","categories":["food","environment","microbiology"],"row_index":148,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Przeźmierowo","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E Presence of microorganisms Culture method with biochemical and microscopic confirmation Microbiology Laboratory Przeźmierowo E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy","technique_en":"Culture method with biochemical and microscopic confirmation","test_object_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E、来自食品生产与流通场所的环境样品 E 微生物的检出 培养法（附生化与显微确证） 普热兹米耶罗沃微生物检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy","methodology_zh":"微生物的检出","technique_zh":"培养法（附生化与显微确证）","lab_section_zh":"普热兹米耶罗沃微生物检验室","test_object_zh":"食品 E、动物饲料 E、来自食品生产与流通场所的环境样品 E"},{"_id":"6a7d76396040ebab2620d30c","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Mikrobiologii Przeźmierowo","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy Zywnosc E, Pasze dla zwierzat E, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy","categories":["food","environment","microbiology"],"row_index":149,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Przeźmierowo","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E Presence of microorganisms Culture method with biochemical and serological confirmation Microbiology Laboratory Przeźmierowo E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E、来自食品生产与流通场所的环境样品 E 微生物的检出 培养法结合生化与血清学确认 普热兹米耶罗沃微生物检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy","technique_zh":"培养法结合生化与血清学确认","methodology_zh":"微生物的检出","lab_section_zh":"普热兹米耶罗沃微生物检验室","test_object_zh":"食品 E、动物饲料 E、来自食品生产与流通场所的环境样品 E"},{"_id":"6a7d76396040ebab2620d30d","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E, Woda do spożycia przez ludzi, woda powierzchniowa, woda na pływalniach, woda E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Przeźmierowo","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E, Woda do spożycia przez ludzi, woda powierzchniowa, woda na pływalniach, woda E Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Normy Procedury badawcze Zywnosc, Pasze dla zwierzat E, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia E, Woda do spozycia przez ludzi, woda powierzchniowa, woda na plywalniach, woda E Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Normy Procedury badawcze","categories":["food","water","environment","microbiology"],"row_index":150,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Przeźmierowo","methodology_en":"Microorganism count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food, Animal feed E, Environmental samples from food production and food trade areas E, Water intended for human consumption, surface water, swimming pool water, water E Microorganism count Plate method (pour plate) Microbiology Laboratory Przeźmierowo E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Plate method (pour plate)","test_object_en":"Food, Animal feed E, Environmental samples from food production and food trade areas E, Water intended for human consumption, surface water, swimming pool water, water E","methodology_zh":"菌落总数","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"菌落总数 平板法（倾注培养） 普热兹米耶罗沃微生物检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"平板法（倾注培养）","lab_section_zh":"普热兹米耶罗沃微生物检验室"},{"_id":"6a7d76396040ebab2620d30e","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E","methodology":"Najbardziej prawdopodobna liczba drobnoustrojów","parameters":[],"technique":"Metoda NPL (probówkowa)","techniques":["Metoda NPL (probówkowa)"],"computed":[],"activity":"Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda NPL (probówkowa)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Mikrobiologii Przeźmierowo","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda NPL (probówkowa) Normy Zywnosc E, Pasze dla zwierzat E Najbardziej prawdopodobna liczba drobnoustrojow\nMetoda NPL (probowkowa) Normy","categories":["food","microbiology"],"row_index":151,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Przeźmierowo","methodology_en":"Most probable number of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E Most probable number of microorganisms MPN method (tube) Microbiology Laboratory Przeźmierowo E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy","technique_en":"MPN method (tube)","test_object_en":"Food E, Animal feed E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E 微生物最可能数 MPN 法（试管法） 普热兹米耶罗沃微生物检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy","lab_section_zh":"普热兹米耶罗沃微生物检验室","methodology_zh":"微生物最可能数","test_object_zh":"食品 E、动物饲料 E","technique_zh":"MPN 法（试管法）"},{"_id":"6a7d76396040ebab2620d30f","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda powierzchniowa, woda na pływalniach, woda E","methodology":"Obecność i liczba drobnoustrojów","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Obecność i liczba drobnoustrojów\nMetoda filtracji membranowej","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Mikrobiologii Przeźmierowo","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Woda do spożycia przez ludzi, woda powierzchniowa, woda na pływalniach, woda E Obecność i liczba drobnoustrojów\nMetoda filtracji membranowej Normy Woda do spozycia przez ludzi, woda powierzchniowa, woda na plywalniach, woda E Obecnosc i liczba drobnoustrojow\nMetoda filtracji membranowej Normy","categories":["water","microbiology"],"row_index":152,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Przeźmierowo","methodology_en":"Presence and count of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Water intended for human consumption, surface water, swimming pool water, water E Presence and count of microorganisms Membrane filtration method Microbiology Laboratory Przeźmierowo E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption, surface water, swimming pool water, water E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"膜过滤法 普热兹米耶罗沃微生物检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy","technique_zh":"膜过滤法","lab_section_zh":"普热兹米耶罗沃微生物检验室"},{"_id":"6a7d76396040ebab2620d310","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa","techniques":["Metoda płytkowa"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Przeźmierowo","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E Liczba drobnoustrojów\nMetoda płytkowa Normy Procedury badawcze Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia E Liczba drobnoustrojow\nMetoda plytkowa Normy Procedury badawcze","categories":["food","environment","microbiology"],"row_index":153,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Przeźmierowo","methodology_en":"Microorganism count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Environmental samples from food production and food trade areas E Microorganism count Plate method Microbiology Laboratory Przeźmierowo E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Plate method","test_object_en":"Environmental samples from food production and food trade areas E","methodology_zh":"菌落总数","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品生产与流通场所的环境样品 E 菌落总数 平板法 普热兹米耶罗沃微生物检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"平板法","test_object_zh":"食品生产与流通场所的环境样品 E","lab_section_zh":"普热兹米耶罗沃微生物检验室"},{"_id":"6a7d76396040ebab2620d311","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze i karmy dla zwierząt E, Obiekty z obszaru produkcji żywności i pasz E","methodology":"Wykrywanie specyficznego DNA dla drobnoustroju, System MDS, metoda isoPCR (izotermiczna reakcja łańcuchowa polimerazy)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wykrywanie specyficznego DNA dla drobnoustroju, System MDS, metoda isoPCR (izotermiczna reakcja łańcuchowa polimerazy)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Przeźmierowo","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze i karmy dla zwierząt E, Obiekty z obszaru produkcji żywności i pasz E Wykrywanie specyficznego DNA dla drobnoustroju, System MDS, metoda isoPCR (izotermiczna reakcja łańcuchowa polimerazy) Procedury badawcze Zywnosc E, Pasze i karmy dla zwierzat E, Obiekty z obszaru produkcji zywnosci i pasz E Wykrywanie specyficznego DNA dla drobnoustroju, System MDS, metoda isoPCR (izotermiczna reakcja lancuchowa polimerazy) Procedury badawcze","categories":["food","materials","microbiology"],"row_index":154,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Przeźmierowo","methodology_en":"Detection of DNA specific to a microorganism, MDS System, isoPCR method (isothermal polymerase chain reaction)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Feed and pet food E, Items from the food and feed production area E Detection of DNA specific to a microorganism, MDS System, isoPCR method (isothermal polymerase chain reaction) Microbiology Laboratory Przeźmierowo E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Procedury badawcze","test_object_en":"Food E, Feed and pet food E, Items from the food and feed production area E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"普热兹米耶罗沃微生物检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Procedury badawcze","lab_section_zh":"普热兹米耶罗沃微生物检验室"},{"_id":"6a7d76396040ebab2620d312","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności oraz obrotu żywnością E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności oraz obrotu żywnością E Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy) Normy Procedury badawcze Zywnosc E, Pasze dla zwierzat E, Probki srodowiskowe z obszarow produkcji zywnosci oraz obrotu zywnoscia E Liczba drobnoustrojow\nMetoda plytkowa (posiew powierzchniowy) Normy Procedury badawcze","categories":["food","environment","microbiology"],"row_index":155,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Tychy","methodology_en":"Microorganism count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E Microorganism count Plate method (spread plate) Microbiology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Plate method (spread plate)","test_object_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E","methodology_zh":"菌落总数","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"菌落总数 平板法（表面涂布） 微生物实验室 Tychy E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"平板法（表面涂布）","lab_section_zh":"微生物实验室 Tychy"},{"_id":"6a7d76396040ebab2620d313","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności oraz obrotu żywnością E, Woda do spożycia przez ludzi, woda powierzchniowa, woda na pływalniach E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności oraz obrotu żywnością E, Woda do spożycia przez ludzi, woda powierzchniowa, woda na pływalniach E Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Normy Procedury badawcze Zywnosc E, Pasze dla zwierzat E, Probki srodowiskowe z obszarow produkcji zywnosci oraz obrotu zywnoscia E, Woda do spozycia przez ludzi, woda powierzchniowa, woda na plywalniach E Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Normy Procedury badawcze","categories":["food","water","environment","microbiology"],"row_index":156,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Tychy","methodology_en":"Microorganism count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E, Water intended for human consumption, surface water, swimming pool water E Microorganism count Plate method (pour plate) Microbiology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Plate method (pour plate)","test_object_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E, Water intended for human consumption, surface water, swimming pool water E","methodology_zh":"菌落总数","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"菌落总数 平板法（倾注培养） 微生物实验室 Tychy E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"平板法（倾注培养）","lab_section_zh":"微生物实验室 Tychy"},{"_id":"6a7d76396040ebab2620d314","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana probówkowa","techniques":["Metoda hodowlana probówkowa"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana probówkowa","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E Obecność drobnoustrojów\nMetoda hodowlana probówkowa Normy Procedury badawcze Zywnosc E, Pasze dla zwierzat E, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia E Obecnosc drobnoustrojow\nMetoda hodowlana probowkowa Normy Procedury badawcze","categories":["food","environment","microbiology"],"row_index":157,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Tychy","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E Presence of microorganisms Tube culture method Microbiology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Tube culture method","test_object_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E、来自食品生产与流通场所的环境样品 E 微生物的检出 试管培养法 微生物实验室 Tychy E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","methodology_zh":"微生物的检出","lab_section_zh":"微生物实验室 Tychy","technique_zh":"试管培养法","test_object_zh":"食品 E、动物饲料 E、来自食品生产与流通场所的环境样品 E"},{"_id":"6a7d76396040ebab2620d315","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana probówkowa z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana probówkowa z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana probówkowa z potwierdzeniem biochemicznym","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E Obecność drobnoustrojów\nMetoda hodowlana probówkowa z potwierdzeniem biochemicznym Normy Procedury badawcze Zywnosc E, Pasze dla zwierzat E, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia E Obecnosc drobnoustrojow\nMetoda hodowlana probowkowa z potwierdzeniem biochemicznym Normy Procedury badawcze","categories":["food","environment","microbiology"],"row_index":158,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Tychy","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E Presence of microorganisms Tube culture method with biochemical confirmation Microbiology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Tube culture method with biochemical confirmation","test_object_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E、来自食品生产与流通场所的环境样品 E 微生物的检出 试管培养法（附生化确证） 微生物实验室 Tychy E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","methodology_zh":"微生物的检出","lab_section_zh":"微生物实验室 Tychy","test_object_zh":"食品 E、动物饲料 E、来自食品生产与流通场所的环境样品 E","technique_zh":"试管培养法（附生化确证）"},{"_id":"6a7d76396040ebab2620d316","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym Normy Procedury badawcze Zywnosc E, Pasze dla zwierzat E, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym Normy Procedury badawcze","categories":["food","environment","microbiology"],"row_index":159,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Tychy","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E Presence of microorganisms Culture method with biochemical confirmation Microbiology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Culture method with biochemical confirmation","test_object_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E、来自食品生产与流通场所的环境样品 E 微生物的检出 培养法结合生化确认 微生物实验室 Tychy E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"培养法结合生化确认","methodology_zh":"微生物的检出","lab_section_zh":"微生物实验室 Tychy","test_object_zh":"食品 E、动物饲料 E、来自食品生产与流通场所的环境样品 E"},{"_id":"6a7d76396040ebab2620d317","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy Procedury badawcze Zywnosc E, Pasze dla zwierzat E, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy Procedury badawcze","categories":["food","environment","microbiology"],"row_index":160,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Tychy","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E Presence of microorganisms Culture method with biochemical and serological confirmation Microbiology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E、来自食品生产与流通场所的环境样品 E 微生物的检出 培养法结合生化与血清学确认 微生物实验室 Tychy E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"培养法结合生化与血清学确认","methodology_zh":"微生物的检出","lab_section_zh":"微生物实验室 Tychy","test_object_zh":"食品 E、动物饲料 E、来自食品生产与流通场所的环境样品 E"},{"_id":"6a7d76396040ebab2620d318","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Mikrobiologii Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym Normy Zywnosc E, Pasze dla zwierzat E, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym Normy","categories":["food","environment","microbiology"],"row_index":161,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Tychy","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E Presence of microorganisms Culture method with biochemical and microscopic confirmation Microbiology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy","technique_en":"Culture method with biochemical and microscopic confirmation","test_object_en":"Food E, Animal feed E, Environmental samples from food production and food trade areas E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E、来自食品生产与流通场所的环境样品 E 微生物的检出 培养法（附生化与显微确证） 微生物实验室 Tychy E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy","methodology_zh":"微生物的检出","technique_zh":"培养法（附生化与显微确证）","lab_section_zh":"微生物实验室 Tychy","test_object_zh":"食品 E、动物饲料 E、来自食品生产与流通场所的环境样品 E"},{"_id":"6a7d76396040ebab2620d319","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E","methodology":"Najbardziej prawdopodobna liczba drobnoustrojów","parameters":[],"technique":"Metoda NPL probówkowa","techniques":["Metoda NPL probówkowa"],"computed":[],"activity":"Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda NPL probówkowa","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Mikrobiologii Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda NPL probówkowa Normy Zywnosc E, Pasze dla zwierzat E Najbardziej prawdopodobna liczba drobnoustrojow\nMetoda NPL probowkowa Normy","categories":["food","microbiology"],"row_index":162,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Tychy","methodology_en":"Most probable number of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E Most probable number of microorganisms MPN tube method Microbiology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy","technique_en":"MPN tube method","test_object_en":"Food E, Animal feed E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E 微生物最可能数 试管 MPN 法 微生物实验室 Tychy E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy","lab_section_zh":"微生物实验室 Tychy","methodology_zh":"微生物最可能数","test_object_zh":"食品 E、动物饲料 E","technique_zh":"试管 MPN 法"},{"_id":"6a7d76396040ebab2620d31a","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda powierzchniowa, woda na pływalniach, woda E","methodology":"Obecność i liczba drobnoustrojów","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Obecność i liczba drobnoustrojów\nMetoda filtracji membranowej","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Mikrobiologii Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Woda do spożycia przez ludzi, woda powierzchniowa, woda na pływalniach, woda E Obecność i liczba drobnoustrojów\nMetoda filtracji membranowej Normy Woda do spozycia przez ludzi, woda powierzchniowa, woda na plywalniach, woda E Obecnosc i liczba drobnoustrojow\nMetoda filtracji membranowej Normy","categories":["water","microbiology"],"row_index":163,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Tychy","methodology_en":"Presence and count of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Water intended for human consumption, surface water, swimming pool water, water E Presence and count of microorganisms Membrane filtration method Microbiology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption, surface water, swimming pool water, water E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"膜过滤法 微生物实验室 Tychy E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy","technique_zh":"膜过滤法","lab_section_zh":"微生物实验室 Tychy"},{"_id":"6a7d76396040ebab2620d31b","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności oraz obrotu żywnością E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa","techniques":["Metoda płytkowa"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności oraz obrotu żywnością E Liczba drobnoustrojów\nMetoda płytkowa Normy Procedury badawcze Probki srodowiskowe z obszarow produkcji zywnosci oraz obrotu zywnoscia E Liczba drobnoustrojow\nMetoda plytkowa Normy Procedury badawcze","categories":["food","environment","microbiology"],"row_index":164,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Tychy","methodology_en":"Microorganism count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Environmental samples from food production and food trade areas E Microorganism count Plate method Microbiology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Plate method","test_object_en":"Environmental samples from food production and food trade areas E","methodology_zh":"菌落总数","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"菌落总数 平板法 微生物实验室 Tychy E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"平板法","lab_section_zh":"微生物实验室 Tychy"},{"_id":"6a7d76396040ebab2620d31c","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Papier, tektura, wyroby z papieru i tektury E, Wyroby z tworzyw sztucznych i wyroby z gumy E, Wyroby z metalu, szkła i ceramiki E, Drewno i wyroby z drewna E - wymazy z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Mikrobiologii Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Papier, tektura, wyroby z papieru i tektury E, Wyroby z tworzyw sztucznych i wyroby z gumy E, Wyroby z metalu, szkła i ceramiki E, Drewno i wyroby z drewna E - wymazy z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Normy Papier, tektura, wyroby z papieru i tektury E, Wyroby z tworzyw sztucznych i wyroby z gumy E, Wyroby z metalu, szkla i ceramiki E, Drewno i wyroby z drewna E - wymazy z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Normy","categories":["materials","microbiology"],"row_index":165,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Tychy","methodology_en":"Microorganism count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Paper, board, paper and board products E, Plastic products and rubber products E, Metal, glass and ceramic products E, Wood and wood products E - swabs from a template-delimited surface - swabs from a surface not delimited by a template Microorganism count Plate method (pour plate) Microbiology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy","technique_en":"Plate method (pour plate)","test_object_en":"Paper, board, paper and board products E, Plastic products and rubber products E, Metal, glass and ceramic products E, Wood and wood products E - swabs from a template-delimited surface - swabs from a surface not delimited by a template","methodology_zh":"菌落总数","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"纸、纸板、纸与纸板制品 E，塑料制品与橡胶制品 E，金属、玻璃与陶瓷制品 E，木材与木制品 E － 用模板限定面积的涂抹样 － 未用模板限定面积的涂抹样 菌落总数 平板法（倾注培养） 微生物实验室 Tychy E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy","technique_zh":"平板法（倾注培养）","lab_section_zh":"微生物实验室 Tychy","test_object_zh":"纸、纸板、纸与纸板制品 E，塑料制品与橡胶制品 E，金属、玻璃与陶瓷制品 E，木材与木制品 E － 用模板限定面积的涂抹样 － 未用模板限定面积的涂抹样"},{"_id":"6a7d76396040ebab2620d31d","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Papier, tektura, wyroby z papieru i tektury E, Wyroby z tworzyw sztucznych i wyroby z gumy E, Wyroby z metalu, szkła i ceramiki E, Drewno i wyroby z drewna E - wymazy z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 6888-1","norm_bases":["PN-EN ISO 6888-1"],"lab_section":"Pracownia Mikrobiologii Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Papier, tektura, wyroby z papieru i tektury E, Wyroby z tworzyw sztucznych i wyroby z gumy E, Wyroby z metalu, szkła i ceramiki E, Drewno i wyroby z drewna E - wymazy z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 6888-1 Papier, tektura, wyroby z papieru i tektury E, Wyroby z tworzyw sztucznych i wyroby z gumy E, Wyroby z metalu, szkla i ceramiki E, Drewno i wyroby z drewna E - wymazy z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem Liczba drobnoustrojow\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 6888-1","categories":["materials","microbiology"],"row_index":166,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Tychy","methodology_en":"Microorganism count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Paper, board, paper and board products E, Plastic products and rubber products E, Metal, glass and ceramic products E, Wood and wood products E - swabs from a template-delimited surface - swabs from a surface not delimited by a template Microorganism count Plate method (spread plate) Microbiology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. PN-EN ISO 6888-1","technique_en":"Plate method (spread plate)","test_object_en":"Paper, board, paper and board products E, Plastic products and rubber products E, Metal, glass and ceramic products E, Wood and wood products E - swabs from a template-delimited surface - swabs from a surface not delimited by a template","methodology_zh":"菌落总数","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"纸、纸板、纸与纸板制品 E，塑料制品与橡胶制品 E，金属、玻璃与陶瓷制品 E，木材与木制品 E － 用模板限定面积的涂抹样 － 未用模板限定面积的涂抹样 菌落总数 平板法（表面涂布） 微生物实验室 Tychy E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 PN-EN ISO 6888-1","technique_zh":"平板法（表面涂布）","lab_section_zh":"微生物实验室 Tychy","test_object_zh":"纸、纸板、纸与纸板制品 E，塑料制品与橡胶制品 E，金属、玻璃与陶瓷制品 E，木材与木制品 E － 用模板限定面积的涂抹样 － 未用模板限定面积的涂抹样"},{"_id":"6a7d76396040ebab2620d31e","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Papier, tektura, wyroby z papieru i tektury E, Wyroby z tworzyw sztucznych i wyroby z gumy E, Wyroby z metalu, szkła i ceramiki E, Drewno i wyroby z drewna E - wymazy z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana probówkowa","techniques":["Metoda hodowlana probówkowa"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana probówkowa","reference":"PN-ISO 4831","norm_bases":["PN-ISO 4831"],"lab_section":"Pracownia Mikrobiologii Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Papier, tektura, wyroby z papieru i tektury E, Wyroby z tworzyw sztucznych i wyroby z gumy E, Wyroby z metalu, szkła i ceramiki E, Drewno i wyroby z drewna E - wymazy z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem Obecność drobnoustrojów\nMetoda hodowlana probówkowa PN-ISO 4831 Papier, tektura, wyroby z papieru i tektury E, Wyroby z tworzyw sztucznych i wyroby z gumy E, Wyroby z metalu, szkla i ceramiki E, Drewno i wyroby z drewna E - wymazy z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem Obecnosc drobnoustrojow\nMetoda hodowlana probowkowa PN-ISO 4831","categories":["materials","microbiology"],"row_index":167,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Tychy","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Paper, board, paper and board products E, Plastic products and rubber products E, Metal, glass and ceramic products E, Wood and wood products E - swabs from a template-delimited surface - swabs from a surface not delimited by a template Presence of microorganisms Tube culture method Microbiology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. PN-ISO 4831","technique_en":"Tube culture method","test_object_en":"Paper, board, paper and board products E, Plastic products and rubber products E, Metal, glass and ceramic products E, Wood and wood products E - swabs from a template-delimited surface - swabs from a surface not delimited by a template","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"纸、纸板、纸与纸板制品 E，塑料制品与橡胶制品 E，金属、玻璃与陶瓷制品 E，木材与木制品 E － 用模板限定面积的涂抹样 － 未用模板限定面积的涂抹样 微生物的检出 试管培养法 微生物实验室 Tychy E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 PN-ISO 4831","methodology_zh":"微生物的检出","lab_section_zh":"微生物实验室 Tychy","technique_zh":"试管培养法","test_object_zh":"纸、纸板、纸与纸板制品 E，塑料制品与橡胶制品 E，金属、玻璃与陶瓷制品 E，木材与木制品 E － 用模板限定面积的涂抹样 － 未用模板限定面积的涂抹样"},{"_id":"6a7d76396040ebab2620d31f","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Papier, tektura, wyroby z papieru i tektury E, Wyroby z tworzyw sztucznych i wyroby z gumy E, Wyroby z metalu, szkła i ceramiki E, Drewno i wyroby z drewna E - wymazy z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana probówkowa z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana probówkowa z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana probówkowa z potwierdzeniem biochemicznym","reference":"PN-ISO 7251","norm_bases":["PN-ISO 7251"],"lab_section":"Pracownia Mikrobiologii Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Papier, tektura, wyroby z papieru i tektury E, Wyroby z tworzyw sztucznych i wyroby z gumy E, Wyroby z metalu, szkła i ceramiki E, Drewno i wyroby z drewna E - wymazy z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem Obecność drobnoustrojów\nMetoda hodowlana probówkowa z potwierdzeniem biochemicznym PN-ISO 7251 Papier, tektura, wyroby z papieru i tektury E, Wyroby z tworzyw sztucznych i wyroby z gumy E, Wyroby z metalu, szkla i ceramiki E, Drewno i wyroby z drewna E - wymazy z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem Obecnosc drobnoustrojow\nMetoda hodowlana probowkowa z potwierdzeniem biochemicznym PN-ISO 7251","categories":["materials","microbiology"],"row_index":168,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Tychy","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Paper, board, paper and board products E, Plastic products and rubber products E, Metal, glass and ceramic products E, Wood and wood products E - swabs from a template-delimited surface - swabs from a surface not delimited by a template Presence of microorganisms Tube culture method with biochemical confirmation Microbiology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. PN-ISO 7251","technique_en":"Tube culture method with biochemical confirmation","test_object_en":"Paper, board, paper and board products E, Plastic products and rubber products E, Metal, glass and ceramic products E, Wood and wood products E - swabs from a template-delimited surface - swabs from a surface not delimited by a template","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"纸、纸板、纸与纸板制品 E，塑料制品与橡胶制品 E，金属、玻璃与陶瓷制品 E，木材与木制品 E － 用模板限定面积的涂抹样 － 未用模板限定面积的涂抹样 微生物的检出 试管培养法（附生化确证） 微生物实验室 Tychy E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 PN-ISO 7251","methodology_zh":"微生物的检出","lab_section_zh":"微生物实验室 Tychy","technique_zh":"试管培养法（附生化确证）","test_object_zh":"纸、纸板、纸与纸板制品 E，塑料制品与橡胶制品 E，金属、玻璃与陶瓷制品 E，木材与木制品 E － 用模板限定面积的涂抹样 － 未用模板限定面积的涂抹样"},{"_id":"6a7d76396040ebab2620d320","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Papier, tektura, wyroby z papieru i tektury E, Wyroby z tworzyw sztucznych i wyroby z gumy E, Wyroby z metalu, szkła i ceramiki E, Drewno i wyroby z drewna E - wymazy z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 11290-1","norm_bases":["PN-EN ISO 11290-1"],"lab_section":"Pracownia Mikrobiologii Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Papier, tektura, wyroby z papieru i tektury E, Wyroby z tworzyw sztucznych i wyroby z gumy E, Wyroby z metalu, szkła i ceramiki E, Drewno i wyroby z drewna E - wymazy z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290-1 Papier, tektura, wyroby z papieru i tektury E, Wyroby z tworzyw sztucznych i wyroby z gumy E, Wyroby z metalu, szkla i ceramiki E, Drewno i wyroby z drewna E - wymazy z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290-1","categories":["materials","microbiology"],"row_index":169,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Tychy","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Paper, board, paper and board products E, Plastic products and rubber products E, Metal, glass and ceramic products E, Wood and wood products E - swabs from a template-delimited surface - swabs from a surface not delimited by a template Presence of microorganisms Culture method with biochemical confirmation Microbiology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. PN-EN ISO 11290-1","technique_en":"Culture method with biochemical confirmation","test_object_en":"Paper, board, paper and board products E, Plastic products and rubber products E, Metal, glass and ceramic products E, Wood and wood products E - swabs from a template-delimited surface - swabs from a surface not delimited by a template","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"纸、纸板、纸与纸板制品 E，塑料制品与橡胶制品 E，金属、玻璃与陶瓷制品 E，木材与木制品 E － 用模板限定面积的涂抹样 － 未用模板限定面积的涂抹样 微生物的检出 培养法结合生化确认 微生物实验室 Tychy E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 PN-EN ISO 11290-1","technique_zh":"培养法结合生化确认","methodology_zh":"微生物的检出","lab_section_zh":"微生物实验室 Tychy","test_object_zh":"纸、纸板、纸与纸板制品 E，塑料制品与橡胶制品 E，金属、玻璃与陶瓷制品 E，木材与木制品 E － 用模板限定面积的涂抹样 － 未用模板限定面积的涂抹样"},{"_id":"6a7d76396040ebab2620d321","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Papier, tektura, wyroby z papieru i tektury E, Wyroby z tworzyw sztucznych i wyroby z gumy E, Wyroby z metalu, szkła i ceramiki E, Drewno i wyroby z drewna E - wymazy z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579-1","norm_bases":["PN-EN ISO 6579-1"],"lab_section":"Pracownia Mikrobiologii Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Papier, tektura, wyroby z papieru i tektury E, Wyroby z tworzyw sztucznych i wyroby z gumy E, Wyroby z metalu, szkła i ceramiki E, Drewno i wyroby z drewna E - wymazy z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1 Papier, tektura, wyroby z papieru i tektury E, Wyroby z tworzyw sztucznych i wyroby z gumy E, Wyroby z metalu, szkla i ceramiki E, Drewno i wyroby z drewna E - wymazy z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1","categories":["materials","microbiology"],"row_index":170,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Tychy","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Paper, board, paper and board products E, Plastic products and rubber products E, Metal, glass and ceramic products E, Wood and wood products E - swabs from a template-delimited surface - swabs from a surface not delimited by a template Presence of microorganisms Culture method with biochemical and serological confirmation Microbiology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. PN-EN ISO 6579-1","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Paper, board, paper and board products E, Plastic products and rubber products E, Metal, glass and ceramic products E, Wood and wood products E - swabs from a template-delimited surface - swabs from a surface not delimited by a template","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"纸、纸板、纸与纸板制品 E，塑料制品与橡胶制品 E，金属、玻璃与陶瓷制品 E，木材与木制品 E － 用模板限定面积的涂抹样 － 未用模板限定面积的涂抹样 微生物的检出 培养法结合生化与血清学确认 微生物实验室 Tychy E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 PN-EN ISO 6579-1","technique_zh":"培养法结合生化与血清学确认","methodology_zh":"微生物的检出","lab_section_zh":"微生物实验室 Tychy","test_object_zh":"纸、纸板、纸与纸板制品 E，塑料制品与橡胶制品 E，金属、玻璃与陶瓷制品 E，木材与木制品 E － 用模板限定面积的涂抹样 － 未用模板限定面积的涂抹样"},{"_id":"6a7d76396040ebab2620d322","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E","methodology":"Najbardziej prawdopodobna liczba drobnoustrojów","parameters":[],"technique":"Metoda NPL (probówkowa)","techniques":["Metoda NPL (probówkowa)"],"computed":[],"activity":"Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda NPL (probówkowa)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Mikrobiologii Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda NPL (probówkowa) Normy Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia E Najbardziej prawdopodobna liczba drobnoustrojow\nMetoda NPL (probowkowa) Normy","categories":["food","environment","microbiology"],"row_index":171,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Tychy","methodology_en":"Most probable number of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Environmental samples from food production and food trade areas E Most probable number of microorganisms MPN method (tube) Microbiology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy","technique_en":"MPN method (tube)","test_object_en":"Environmental samples from food production and food trade areas E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品生产与流通场所的环境样品 E 微生物最可能数 MPN 法（试管法） 微生物实验室 Tychy E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy","lab_section_zh":"微生物实验室 Tychy","test_object_zh":"食品生产与流通场所的环境样品 E","methodology_zh":"微生物最可能数","technique_zh":"MPN 法（试管法）"},{"_id":"6a7d76396040ebab2620d323","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze i karmy dla zwierząt E, Obiekty z obszaru produkcji żywności i pasz E","methodology":"Wykrywanie specyficznego DNA dla drobnoustroju, System MDS, metoda isoPCR (izotermiczna reakcja łańcuchowa polimerazy)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wykrywanie specyficznego DNA dla drobnoustroju, System MDS, metoda isoPCR (izotermiczna reakcja łańcuchowa polimerazy)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze i karmy dla zwierząt E, Obiekty z obszaru produkcji żywności i pasz E Wykrywanie specyficznego DNA dla drobnoustroju, System MDS, metoda isoPCR (izotermiczna reakcja łańcuchowa polimerazy) Procedury badawcze Zywnosc E, Pasze i karmy dla zwierzat E, Obiekty z obszaru produkcji zywnosci i pasz E Wykrywanie specyficznego DNA dla drobnoustroju, System MDS, metoda isoPCR (izotermiczna reakcja lancuchowa polimerazy) Procedury badawcze","categories":["food","materials","microbiology"],"row_index":172,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Tychy","methodology_en":"Detection of DNA specific to a microorganism, MDS System, isoPCR method (isothermal polymerase chain reaction)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Feed and pet food E, Items from the food and feed production area E Detection of DNA specific to a microorganism, MDS System, isoPCR method (isothermal polymerase chain reaction) Microbiology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Procedury badawcze","test_object_en":"Food E, Feed and pet food E, Items from the food and feed production area E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"微生物实验室 Tychy E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Procedury badawcze","lab_section_zh":"微生物实验室 Tychy"},{"_id":"6a7d76396040ebab2620d324","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Papier, tektura, wyroby z papieru i tektury","methodology":"Przenikalność składników przeciwdrobnoustrojowych","parameters":[],"technique":"Metoda hodowlana, dyfuzyjna","techniques":["Metoda hodowlana, dyfuzyjna"],"computed":[],"activity":"Przenikalność składników przeciwdrobnoustrojowych\nMetoda hodowlana, dyfuzyjna","reference":"PN-EN 1104:2019-02","norm_bases":["PN-EN 1104:2019-02"],"lab_section":"Pracownia Mikrobiologii Kosmetyków Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Papier, tektura, wyroby z papieru i tektury Przenikalność składników przeciwdrobnoustrojowych\nMetoda hodowlana, dyfuzyjna PN-EN 1104:2019-02 Papier, tektura, wyroby z papieru i tektury Przenikalnosc skladnikow przeciwdrobnoustrojowych\nMetoda hodowlana, dyfuzyjna PN-EN 1104:2019-02","categories":["other"],"row_index":173,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Cosmetics Microbiology Laboratory Tychy","methodology_en":"Permeability of antimicrobial components","search_en":"Paper, board, paper and board products Permeability of antimicrobial components Culture method, diffusion Cosmetics Microbiology Laboratory Tychy PN-EN 1104:2019-02","technique_en":"Culture method, diffusion","test_object_en":"Paper, board, paper and board products","lab_section_zh":"蒂黑化妆品微生物检验室","search_zh":"蒂黑化妆品微生物检验室 PN-EN 1104:2019-02"},{"_id":"6a7d76396040ebab2620d325","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Chemiczne środki dezynfekcyjne i antyseptyczne","methodology":"Skuteczność działania środków dezynfekcyjnych i antyseptycznych","parameters":[],"technique":"Metoda higienicznego mycia rąk","techniques":["Metoda higienicznego mycia rąk"],"computed":[],"activity":"Skuteczność działania środków dezynfekcyjnych i antyseptycznych\nMetoda higienicznego mycia rąk","reference":"PN-EN 1499:2013-07","norm_bases":["PN-EN 1499:2013-07"],"lab_section":"Pracownia Mikrobiologii Kosmetyków Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Chemiczne środki dezynfekcyjne i antyseptyczne Skuteczność działania środków dezynfekcyjnych i antyseptycznych\nMetoda higienicznego mycia rąk PN-EN 1499:2013-07 Chemiczne srodki dezynfekcyjne i antyseptyczne Skutecznosc dzialania srodkow dezynfekcyjnych i antyseptycznych\nMetoda higienicznego mycia rak PN-EN 1499:2013-07","categories":["other"],"row_index":174,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Cosmetics Microbiology Laboratory Tychy","methodology_en":"Efficacy of disinfectants and antiseptics","search_en":"Chemical disinfectants and antiseptics Efficacy of disinfectants and antiseptics Hygienic handwash method Cosmetics Microbiology Laboratory Tychy PN-EN 1499:2013-07","technique_en":"Hygienic handwash method","test_object_en":"Chemical disinfectants and antiseptics","lab_section_zh":"蒂黑化妆品微生物检验室","search_zh":"化学消毒剂与防腐剂 消毒剂与防腐剂的作用效果 蒂黑化妆品微生物检验室 PN-EN 1499:2013-07","test_object_zh":"化学消毒剂与防腐剂","methodology_zh":"消毒剂与防腐剂的作用效果"},{"_id":"6a7d76396040ebab2620d326","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Chemiczne środki dezynfekcyjne i antyseptyczne","methodology":"Skuteczność działania środków dezynfekcyjnych i antyseptycznych","parameters":[],"technique":"Metoda wcierania","techniques":["Metoda wcierania"],"computed":[],"activity":"Skuteczność działania środków dezynfekcyjnych i antyseptycznych\nMetoda wcierania","reference":"PN-EN 1500:2013-07","norm_bases":["PN-EN 1500:2013-07"],"lab_section":"Pracownia Mikrobiologii Kosmetyków Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Chemiczne środki dezynfekcyjne i antyseptyczne Skuteczność działania środków dezynfekcyjnych i antyseptycznych\nMetoda wcierania PN-EN 1500:2013-07 Chemiczne srodki dezynfekcyjne i antyseptyczne Skutecznosc dzialania srodkow dezynfekcyjnych i antyseptycznych\nMetoda wcierania PN-EN 1500:2013-07","categories":["other"],"row_index":175,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Cosmetics Microbiology Laboratory Tychy","methodology_en":"Efficacy of disinfectants and antiseptics","search_en":"Chemical disinfectants and antiseptics Efficacy of disinfectants and antiseptics Rubbing method Cosmetics Microbiology Laboratory Tychy PN-EN 1500:2013-07","technique_en":"Rubbing method","test_object_en":"Chemical disinfectants and antiseptics","lab_section_zh":"蒂黑化妆品微生物检验室","search_zh":"化学消毒剂与防腐剂 消毒剂与防腐剂的作用效果 蒂黑化妆品微生物检验室 PN-EN 1500:2013-07","test_object_zh":"化学消毒剂与防腐剂","methodology_zh":"消毒剂与防腐剂的作用效果"},{"_id":"6a7d76396040ebab2620d327","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji kosmetyków oraz obrotu kosmetykami E, Kosmetyki E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Kosmetyków Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji kosmetyków oraz obrotu kosmetykami E, Kosmetyki E Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Normy Procedury badawcze Probki srodowiskowe z obszarow produkcji kosmetykow oraz obrotu kosmetykami E, Kosmetyki E Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Normy Procedury badawcze","categories":["environment","microbiology","pharma"],"row_index":176,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Cosmetics Microbiology Laboratory Tychy","methodology_en":"Microorganism count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Environmental samples from cosmetics production and distribution areas E, Cosmetics E Microorganism count Plate method (pour plate) Cosmetics Microbiology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Plate method (pour plate)","test_object_en":"Environmental samples from cosmetics production and distribution areas E, Cosmetics E","methodology_zh":"菌落总数","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"菌落总数 平板法（倾注培养） 蒂黑化妆品微生物检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"平板法（倾注培养）","lab_section_zh":"蒂黑化妆品微生物检验室"},{"_id":"6a7d76396040ebab2620d328","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Kosmetyki E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana probówkowa","techniques":["Metoda hodowlana probówkowa"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana probówkowa","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Kosmetyków Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Kosmetyki E Obecność drobnoustrojów\nMetoda hodowlana probówkowa Normy Procedury badawcze Kosmetyki E Obecnosc drobnoustrojow\nMetoda hodowlana probowkowa Normy Procedury badawcze","categories":["microbiology","pharma"],"row_index":177,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Cosmetics Microbiology Laboratory Tychy","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Cosmetics E Presence of microorganisms Tube culture method Cosmetics Microbiology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Tube culture method","test_object_en":"Cosmetics E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"化妆品 E 微生物的检出 试管培养法 蒂黑化妆品微生物检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","methodology_zh":"微生物的检出","technique_zh":"试管培养法","lab_section_zh":"蒂黑化妆品微生物检验室","test_object_zh":"化妆品 E"},{"_id":"6a7d76396040ebab2620d329","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Kosmetyki E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana probówkowa z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana probówkowa z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana probówkowa z potwierdzeniem biochemicznym","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Kosmetyków Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Kosmetyki E Obecność drobnoustrojów\nMetoda hodowlana probówkowa z potwierdzeniem biochemicznym Normy Procedury badawcze Kosmetyki E Obecnosc drobnoustrojow\nMetoda hodowlana probowkowa z potwierdzeniem biochemicznym Normy Procedury badawcze","categories":["microbiology","pharma"],"row_index":178,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Cosmetics Microbiology Laboratory Tychy","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Cosmetics E Presence of microorganisms Tube culture method with biochemical confirmation Cosmetics Microbiology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Tube culture method with biochemical confirmation","test_object_en":"Cosmetics E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"化妆品 E 微生物的检出 试管培养法（附生化确证） 蒂黑化妆品微生物检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","methodology_zh":"微生物的检出","lab_section_zh":"蒂黑化妆品微生物检验室","technique_zh":"试管培养法（附生化确证）","test_object_zh":"化妆品 E"},{"_id":"6a7d76396040ebab2620d32a","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Kosmetyki E","methodology":"Skuteczność ochrony przeciwdrobnoustrojowej produktu kosmetycznego","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Skuteczność ochrony przeciwdrobnoustrojowej produktu kosmetycznego\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 11930","norm_bases":["PN-EN ISO 11930"],"lab_section":"Pracownia Mikrobiologii Kosmetyków Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Kosmetyki E Skuteczność ochrony przeciwdrobnoustrojowej produktu kosmetycznego\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 11930 Kosmetyki E Skutecznosc ochrony przeciwdrobnoustrojowej produktu kosmetycznego\nMetoda plytkowa (posiew wglebny) PN-EN ISO 11930","categories":["pharma"],"row_index":179,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Cosmetics Microbiology Laboratory Tychy","methodology_en":"Antimicrobial protection efficacy of the cosmetic product","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Cosmetics E Antimicrobial protection efficacy of the cosmetic product Plate method (pour plate) Cosmetics Microbiology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. PN-EN ISO 11930","technique_en":"Plate method (pour plate)","test_object_en":"Cosmetics E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"化妆品 E 平板法（倾注培养） 蒂黑化妆品微生物检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 PN-EN ISO 11930","technique_zh":"平板法（倾注培养）","lab_section_zh":"蒂黑化妆品微生物检验室","test_object_zh":"化妆品 E"},{"_id":"6a7d76396040ebab2620d32b","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Wyroby chemiczne E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Mikrobiologii Kosmetyków Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Wyroby chemiczne E Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Normy Wyroby chemiczne E Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Normy","categories":["microbiology"],"row_index":180,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Cosmetics Microbiology Laboratory Tychy","methodology_en":"Microorganism count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Chemical products E Microorganism count Plate method (pour plate) Cosmetics Microbiology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy","technique_en":"Plate method (pour plate)","test_object_en":"Chemical products E","methodology_zh":"菌落总数","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"菌落总数 平板法（倾注培养） 蒂黑化妆品微生物检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy","technique_zh":"平板法（倾注培养）","lab_section_zh":"蒂黑化妆品微生物检验室"},{"_id":"6a7d76396040ebab2620d32c","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Wyroby chemiczne E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana probówkowa z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana probówkowa z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana probówkowa z potwierdzeniem biochemicznym","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Mikrobiologii Kosmetyków Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Wyroby chemiczne E Obecność drobnoustrojów\nMetoda hodowlana probówkowa z potwierdzeniem biochemicznym Normy Wyroby chemiczne E Obecnosc drobnoustrojow\nMetoda hodowlana probowkowa z potwierdzeniem biochemicznym Normy","categories":["microbiology"],"row_index":181,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Cosmetics Microbiology Laboratory Tychy","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Chemical products E Presence of microorganisms Tube culture method with biochemical confirmation Cosmetics Microbiology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy","technique_en":"Tube culture method with biochemical confirmation","test_object_en":"Chemical products E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"微生物的检出 试管培养法（附生化确证） 蒂黑化妆品微生物检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy","methodology_zh":"微生物的检出","lab_section_zh":"蒂黑化妆品微生物检验室","technique_zh":"试管培养法（附生化确证）"},{"_id":"6a7d76396040ebab2620d32d","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji kosmetyków oraz obrotu kosmetykami E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa","techniques":["Metoda płytkowa"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Kosmetyków Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji kosmetyków oraz obrotu kosmetykami E Liczba drobnoustrojów\nMetoda płytkowa Normy Procedury badawcze Probki srodowiskowe z obszarow produkcji kosmetykow oraz obrotu kosmetykami E Liczba drobnoustrojow\nMetoda plytkowa Normy Procedury badawcze","categories":["environment","microbiology","pharma"],"row_index":182,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Cosmetics Microbiology Laboratory Tychy","methodology_en":"Microorganism count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Environmental samples from cosmetics production and distribution areas E Microorganism count Plate method Cosmetics Microbiology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Plate method","test_object_en":"Environmental samples from cosmetics production and distribution areas E","methodology_zh":"菌落总数","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"菌落总数 平板法 蒂黑化妆品微生物检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"平板法","lab_section_zh":"蒂黑化妆品微生物检验室"},{"_id":"6a7d76396040ebab2620d32e","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Chemiczne środki dezynfekcyjne i antyseptyczne E","methodology":"Skuteczność działania środków dezynfekcyjnych i antyseptycznych","parameters":[],"technique":"Metoda ilościowa zawiesinowa","techniques":["Metoda ilościowa zawiesinowa"],"computed":[],"activity":"Skuteczność działania środków dezynfekcyjnych i antyseptycznych\nMetoda ilościowa zawiesinowa","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Mikrobiologii Kosmetyków Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Chemiczne środki dezynfekcyjne i antyseptyczne E Skuteczność działania środków dezynfekcyjnych i antyseptycznych\nMetoda ilościowa zawiesinowa Normy Chemiczne srodki dezynfekcyjne i antyseptyczne E Skutecznosc dzialania srodkow dezynfekcyjnych i antyseptycznych\nMetoda ilosciowa zawiesinowa Normy","categories":["other"],"row_index":183,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Cosmetics Microbiology Laboratory Tychy","methodology_en":"Efficacy of disinfectants and antiseptics","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Chemical disinfectants and antiseptics E Efficacy of disinfectants and antiseptics Quantitative suspension method Cosmetics Microbiology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy","technique_en":"Quantitative suspension method","test_object_en":"Chemical disinfectants and antiseptics E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"化学消毒剂与防腐剂 E 消毒剂与防腐剂的作用效果 蒂黑化妆品微生物检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy","lab_section_zh":"蒂黑化妆品微生物检验室","methodology_zh":"消毒剂与防腐剂的作用效果","test_object_zh":"化学消毒剂与防腐剂 E"},{"_id":"6a7d76396040ebab2620d32f","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Chemiczne środki dezynfekcyjne i antyseptyczne E","methodology":"Skuteczność działania środków dezynfekcyjnych i antyseptycznych","parameters":[],"technique":"Metoda badania na nieporowatych powierzchniach","techniques":["Metoda badania na nieporowatych powierzchniach"],"computed":[],"activity":"Skuteczność działania środków dezynfekcyjnych i antyseptycznych\nMetoda badania na nieporowatych powierzchniach","reference":"PN-EN 13697","norm_bases":["PN-EN 13697"],"lab_section":"Pracownia Mikrobiologii Kosmetyków Tychy","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Chemiczne środki dezynfekcyjne i antyseptyczne E Skuteczność działania środków dezynfekcyjnych i antyseptycznych\nMetoda badania na nieporowatych powierzchniach PN-EN 13697 Chemiczne srodki dezynfekcyjne i antyseptyczne E Skutecznosc dzialania srodkow dezynfekcyjnych i antyseptycznych\nMetoda badania na nieporowatych powierzchniach PN-EN 13697","categories":["other"],"row_index":184,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Cosmetics Microbiology Laboratory Tychy","methodology_en":"Efficacy of disinfectants and antiseptics","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Chemical disinfectants and antiseptics E Efficacy of disinfectants and antiseptics Test method on non-porous surfaces Cosmetics Microbiology Laboratory Tychy E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. PN-EN 13697","technique_en":"Test method on non-porous surfaces","test_object_en":"Chemical disinfectants and antiseptics E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"化学消毒剂与防腐剂 E 消毒剂与防腐剂的作用效果 蒂黑化妆品微生物检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 PN-EN 13697","lab_section_zh":"蒂黑化妆品微生物检验室","methodology_zh":"消毒剂与防腐剂的作用效果","test_object_zh":"化学消毒剂与防腐剂 E"},{"_id":"6a7d76396040ebab2620d330","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Surowe mleko i produkty mleczne nie poddane obróbce termicznej, Mleko i produkty mleczne poddane obróbce termicznej","methodology":"Ogólna liczba drobnoustrojów w 30 °C przez 72 h","parameters":[],"technique":"Metoda Petrifilm","techniques":["Metoda Petrifilm"],"computed":[],"activity":"Ogólna liczba drobnoustrojów w 30 °C przez 72 h\nMetoda Petrifilm","reference":"PB-421 wyd. 1 z dn. 07.02.2023 opracowana na podstawie instrukcji producenta płytek 3M Petrifilm","norm_bases":["PB-421 wyd. 1 z dn. 07.02.2023 opracowana na podstawie instrukcji producenta płytek 3M Petrifilm"],"lab_section":"Pracownia Mikrobiologii Maków Mazowiecki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Surowe mleko i produkty mleczne nie poddane obróbce termicznej, Mleko i produkty mleczne poddane obróbce termicznej Ogólna liczba drobnoustrojów w 30 °C przez 72 h\nMetoda Petrifilm PB-421 wyd. 1 z dn. 07.02.2023 opracowana na podstawie instrukcji producenta płytek 3M Petrifilm Surowe mleko i produkty mleczne nie poddane obrobce termicznej, Mleko i produkty mleczne poddane obrobce termicznej Ogolna liczba drobnoustrojow w 30 °C przez 72 h\nMetoda Petrifilm PB-421 wyd. 1 z dn. 07.02.2023 opracowana na podstawie instrukcji producenta plytek 3M Petrifilm","categories":["food","microbiology"],"row_index":185,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Maków Mazowiecki","methodology_en":"Total viable count at 30 °C for 72 h","search_en":"Raw milk and milk products not heat-treated, Milk and milk products subjected to heat treatment Total viable count at 30 °C for 72 h Petrifilm method Microbiology Laboratory Maków Mazowiecki PB-421 wyd. 1 z dn. 07.02.2023 opracowana na podstawie instrukcji producenta płytek 3M Petrifilm","technique_en":"Petrifilm method","test_object_en":"Raw milk and milk products not heat-treated, Milk and milk products subjected to heat treatment","lab_section_zh":"微生物实验室 Maków Mazowiecki","search_zh":"Petrifilm 测试片法 微生物实验室 Maków Mazowiecki PB-421 wyd. 1 z dn. 07.02.2023 opracowana na podstawie instrukcji producenta płytek 3M Petrifilm","technique_zh":"Petrifilm 测试片法"},{"_id":"6a7d76396040ebab2620d331","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Surowe mleko i produkty mleczne nie poddane obróbce termicznej, Mleko i produkty mleczne poddane obróbce termicznej","methodology":"Liczba Enterobacreriaceae w 37 °C przez 24 h","parameters":[],"technique":"Metoda Petrifilm","techniques":["Metoda Petrifilm"],"computed":[],"activity":"Liczba Enterobacreriaceae w 37 °C przez 24 h\nMetoda Petrifilm","reference":"PB-422 wyd. 2 z dn. 05.12.2024 opracowana na podstawie instrukcji producenta płytek 3M Petrifilm","norm_bases":["PB-422 wyd. 2 z dn. 05.12.2024 opracowana na podstawie instrukcji producenta płytek 3M Petrifilm"],"lab_section":"Pracownia Mikrobiologii Maków Mazowiecki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Surowe mleko i produkty mleczne nie poddane obróbce termicznej, Mleko i produkty mleczne poddane obróbce termicznej Liczba Enterobacreriaceae w 37 °C przez 24 h\nMetoda Petrifilm PB-422 wyd. 2 z dn. 05.12.2024 opracowana na podstawie instrukcji producenta płytek 3M Petrifilm Surowe mleko i produkty mleczne nie poddane obrobce termicznej, Mleko i produkty mleczne poddane obrobce termicznej Liczba Enterobacreriaceae w 37 °C przez 24 h\nMetoda Petrifilm PB-422 wyd. 2 z dn. 05.12.2024 opracowana na podstawie instrukcji producenta plytek 3M Petrifilm","categories":["food"],"row_index":186,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Maków Mazowiecki","methodology_en":"Count of Enterobacreriaceae at 37 °C for 24 h","search_en":"Raw milk and milk products not heat-treated, Milk and milk products subjected to heat treatment Count of Enterobacreriaceae at 37 °C for 24 h Petrifilm method Microbiology Laboratory Maków Mazowiecki PB-422 wyd. 2 z dn. 05.12.2024 opracowana na podstawie instrukcji producenta płytek 3M Petrifilm","technique_en":"Petrifilm method","test_object_en":"Raw milk and milk products not heat-treated, Milk and milk products subjected to heat treatment","lab_section_zh":"微生物实验室 Maków Mazowiecki","search_zh":"Petrifilm 测试片法 微生物实验室 Maków Mazowiecki PB-422 wyd. 2 z dn. 05.12.2024 opracowana na podstawie instrukcji producenta płytek 3M Petrifilm","technique_zh":"Petrifilm 测试片法"},{"_id":"6a7d76396040ebab2620d332","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowy drób i surowe produkty drobiowe gotowe do przygotowania, Produkty drobiowe gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Produkty rybne gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Produkty dla niemowląt i płatki dla niemowląt, Czekolada, produkty cukiernicze i pieczywo, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt, Próbki ze środowiska (produkcja żywności i pasz): - wymaz z powierzchni ograniczonej szablonem, - wymaz z powierzchni nieograniczonej szablonem, w tym z rąk - popłuczyny","methodology":"Ogólna liczba drobnoustrojów w 30 °C przez 48 h","parameters":[],"technique":"Metoda Petrifilm","techniques":["Metoda Petrifilm"],"computed":[],"activity":"Ogólna liczba drobnoustrojów w 30 °C przez 48 h\nMetoda Petrifilm","reference":"PB-421 wyd. 1 z dn. 07.02.2023 opracowana na podstawie instrukcji producenta płytek 3M Petrifilm","norm_bases":["PB-421 wyd. 1 z dn. 07.02.2023 opracowana na podstawie instrukcji producenta płytek 3M Petrifilm"],"lab_section":"Pracownia Mikrobiologii Maków Mazowiecki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowy drób i surowe produkty drobiowe gotowe do przygotowania, Produkty drobiowe gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Produkty rybne gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Produkty dla niemowląt i płatki dla niemowląt, Czekolada, produkty cukiernicze i pieczywo, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt, Próbki ze środowiska (produkcja żywności i pasz): - wymaz z powierzchni ograniczonej szablonem, - wymaz z powierzchni nieograniczonej szablonem, w tym z rąk - popłuczyny Ogólna liczba drobnoustrojów w 30 °C przez 48 h\nMetoda Petrifilm PB-421 wyd. 1 z dn. 07.02.2023 opracowana na podstawie instrukcji producenta płytek 3M Petrifilm Surowe mieso i surowe produkty miesne gotowe do przygotowania (oprocz drobiu), Produkty miesne gotowe do spozycia lub gotowe do podgrzania, Surowy drob i surowe produkty drobiowe gotowe do przygotowania, Produkty drobiowe gotowe do spozycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Produkty rybne gotowe do spozycia lub gotowe do podgrzania, Swieze warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboza, owoce, orzechy, nasiona i warzywa, Produkty dla niemowlat i platki dla niemowlat, Czekolada, produkty cukiernicze i pieczywo, Wieloskladnikowe produkty lub elementy posilkow, Pasze i karmy dla zwierzat, Probki ze srodowiska (produkcja zywnosci i pasz): - wymaz z powierzchni ograniczonej szablonem, - wymaz z powierzchni nieograniczonej szablonem, w tym z rak - popluczyny Ogolna liczba drobnoustrojow w 30 °C przez 48 h\nMetoda Petrifilm PB-421 wyd. 1 z dn. 07.02.2023 opracowana na podstawie instrukcji producenta plytek 3M Petrifilm","categories":["food","environment","microbiology"],"row_index":187,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Maków Mazowiecki","methodology_en":"Total viable count at 30 °C for 48 h","search_en":"Raw meat and raw meat products ready for preparation (except poultry), Meat products ready to eat or ready to reheat, Raw poultry and raw poultry products ready for preparation, Poultry products ready to eat or ready to reheat, Eggs and egg products (derivatives), Fish products ready to eat or ready to reheat, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant products and infant cereals, Chocolate, confectionery products and bakery products, Multi-ingredient products or meal components, Feed and pet food, Environmental samples (food and feed production): - swab from a template-delimited surface, - swab from a surface not delimited by a template, including from hands - rinse water Total viable count at 30 °C for 48 h Petrifilm method Microbiology Laboratory Maków Mazowiecki PB-421 wyd. 1 z dn. 07.02.2023 opracowana na podstawie instrukcji producenta płytek 3M Petrifilm","technique_en":"Petrifilm method","test_object_en":"Raw meat and raw meat products ready for preparation (except poultry), Meat products ready to eat or ready to reheat, Raw poultry and raw poultry products ready for preparation, Poultry products ready to eat or ready to reheat, Eggs and egg products (derivatives), Fish products ready to eat or ready to reheat, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant products and infant cereals, Chocolate, confectionery products and bakery products, Multi-ingredient products or meal components, Feed and pet food, Environmental samples (food and feed production): - swab from a template-delimited surface, - swab from a surface not delimited by a template, including from hands - rinse water","lab_section_zh":"微生物实验室 Maków Mazowiecki","search_zh":"Petrifilm 测试片法 微生物实验室 Maków Mazowiecki PB-421 wyd. 1 z dn. 07.02.2023 opracowana na podstawie instrukcji producenta płytek 3M Petrifilm","technique_zh":"Petrifilm 测试片法"},{"_id":"6a7d76396040ebab2620d333","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowy drób i surowe produkty drobiowe gotowe do przygotowania, Produkty drobiowe gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Produkty rybne gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Produkty dla niemowląt i płatki dla niemowląt, Czekolada, produkty cukiernicze i pieczywo, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt, Próbki ze środowiska (produkcja żywności i pasz): - wymaz z powierzchni ograniczonej szablonem, - wymaz z powierzchni nieograniczonej szablonem, w tym z rąk - popłuczyny","methodology":"Liczba Enterobacreriaceae w 37 °C przez 24 h","parameters":[],"technique":"Metoda Petrifilm","techniques":["Metoda Petrifilm"],"computed":[],"activity":"Liczba Enterobacreriaceae w 37 °C przez 24 h\nMetoda Petrifilm","reference":"PB-422 wyd. 2 z dn. 05.12.2024 opracowana na podstawie instrukcji producenta płytek 3M Petrifilm","norm_bases":["PB-422 wyd. 2 z dn. 05.12.2024 opracowana na podstawie instrukcji producenta płytek 3M Petrifilm"],"lab_section":"Pracownia Mikrobiologii Maków Mazowiecki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowy drób i surowe produkty drobiowe gotowe do przygotowania, Produkty drobiowe gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Produkty rybne gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Produkty dla niemowląt i płatki dla niemowląt, Czekolada, produkty cukiernicze i pieczywo, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt, Próbki ze środowiska (produkcja żywności i pasz): - wymaz z powierzchni ograniczonej szablonem, - wymaz z powierzchni nieograniczonej szablonem, w tym z rąk - popłuczyny Liczba Enterobacreriaceae w 37 °C przez 24 h\nMetoda Petrifilm PB-422 wyd. 2 z dn. 05.12.2024 opracowana na podstawie instrukcji producenta płytek 3M Petrifilm Surowe mieso i surowe produkty miesne gotowe do przygotowania (oprocz drobiu), Produkty miesne gotowe do spozycia lub gotowe do podgrzania, Surowy drob i surowe produkty drobiowe gotowe do przygotowania, Produkty drobiowe gotowe do spozycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Produkty rybne gotowe do spozycia lub gotowe do podgrzania, Swieze warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboza, owoce, orzechy, nasiona i warzywa, Produkty dla niemowlat i platki dla niemowlat, Czekolada, produkty cukiernicze i pieczywo, Wieloskladnikowe produkty lub elementy posilkow, Pasze i karmy dla zwierzat, Probki ze srodowiska (produkcja zywnosci i pasz): - wymaz z powierzchni ograniczonej szablonem, - wymaz z powierzchni nieograniczonej szablonem, w tym z rak - popluczyny Liczba Enterobacreriaceae w 37 °C przez 24 h\nMetoda Petrifilm PB-422 wyd. 2 z dn. 05.12.2024 opracowana na podstawie instrukcji producenta plytek 3M Petrifilm","categories":["food","environment"],"row_index":188,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Maków Mazowiecki","methodology_en":"Count of Enterobacreriaceae at 37 °C for 24 h","search_en":"Raw meat and raw meat products ready for preparation (except poultry), Meat products ready to eat or ready to reheat, Raw poultry and raw poultry products ready for preparation, Poultry products ready to eat or ready to reheat, Eggs and egg products (derivatives), Fish products ready to eat or ready to reheat, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant products and infant cereals, Chocolate, confectionery products and bakery products, Multi-ingredient products or meal components, Feed and pet food, Environmental samples (food and feed production): - swab from a template-delimited surface, - swab from a surface not delimited by a template, including from hands - rinse water Count of Enterobacreriaceae at 37 °C for 24 h Petrifilm method Microbiology Laboratory Maków Mazowiecki PB-422 wyd. 2 z dn. 05.12.2024 opracowana na podstawie instrukcji producenta płytek 3M Petrifilm","technique_en":"Petrifilm method","test_object_en":"Raw meat and raw meat products ready for preparation (except poultry), Meat products ready to eat or ready to reheat, Raw poultry and raw poultry products ready for preparation, Poultry products ready to eat or ready to reheat, Eggs and egg products (derivatives), Fish products ready to eat or ready to reheat, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant products and infant cereals, Chocolate, confectionery products and bakery products, Multi-ingredient products or meal components, Feed and pet food, Environmental samples (food and feed production): - swab from a template-delimited surface, - swab from a surface not delimited by a template, including from hands - rinse water","lab_section_zh":"微生物实验室 Maków Mazowiecki","search_zh":"Petrifilm 测试片法 微生物实验室 Maków Mazowiecki PB-422 wyd. 2 z dn. 05.12.2024 opracowana na podstawie instrukcji producenta płytek 3M Petrifilm","technique_zh":"Petrifilm 测试片法"},{"_id":"6a7d76396040ebab2620d334","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa","techniques":["Metoda płytkowa"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Maków Mazowiecki","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E Liczba drobnoustrojów\nMetoda płytkowa Normy Procedury badawcze Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia E Liczba drobnoustrojow\nMetoda plytkowa Normy Procedury badawcze","categories":["food","environment","microbiology"],"row_index":189,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Maków Mazowiecki","methodology_en":"Microorganism count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Environmental samples from food production and food trade areas E Microorganism count Plate method Microbiology Laboratory Maków Mazowiecki E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Plate method","test_object_en":"Environmental samples from food production and food trade areas E","methodology_zh":"菌落总数","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品生产与流通场所的环境样品 E 菌落总数 平板法 微生物实验室 Maków Mazowiecki E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"平板法","lab_section_zh":"微生物实验室 Maków Mazowiecki","test_object_zh":"食品生产与流通场所的环境样品 E"},{"_id":"6a7d76396040ebab2620d335","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością i kosmetykami E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Mikrobiologii Maków Mazowiecki","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością i kosmetykami E Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy) Normy Zywnosc E, Pasze dla zwierzat E, Probki srodowiskowe z obszarow produkcji zywnosci i kosmetykow oraz obrotu zywnoscia i kosmetykami E Liczba drobnoustrojow\nMetoda plytkowa (posiew powierzchniowy) Normy","categories":["food","environment","microbiology","pharma"],"row_index":190,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Maków Mazowiecki","methodology_en":"Microorganism count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E, Environmental samples from areas of food and cosmetics production and food and cosmetics trade E Microorganism count Plate method (spread plate) Microbiology Laboratory Maków Mazowiecki E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy","technique_en":"Plate method (spread plate)","test_object_en":"Food E, Animal feed E, Environmental samples from areas of food and cosmetics production and food and cosmetics trade E","methodology_zh":"菌落总数","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E、来自食品与化妆品生产及食品与化妆品流通场所的环境样品 E 菌落总数 平板法（表面涂布） 微生物实验室 Maków Mazowiecki E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy","technique_zh":"平板法（表面涂布）","lab_section_zh":"微生物实验室 Maków Mazowiecki","test_object_zh":"食品 E、动物饲料 E、来自食品与化妆品生产及食品与化妆品流通场所的环境样品 E"},{"_id":"6a7d76396040ebab2620d336","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji kosmetyków i obrotu kosmetykami E, Woda E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Maków Mazowiecki","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji kosmetyków i obrotu kosmetykami E, Woda E Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Normy Procedury badawcze Zywnosc E, Pasze dla zwierzat E, Probki srodowiskowe z obszarow produkcji kosmetykow i obrotu kosmetykami E, Woda E Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Normy Procedury badawcze","categories":["food","water","environment","microbiology","pharma"],"row_index":191,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Maków Mazowiecki","methodology_en":"Microorganism count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E, Environmental samples from cosmetics production and cosmetics trade areas E, Water E Microorganism count Plate method (pour plate) Microbiology Laboratory Maków Mazowiecki E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Plate method (pour plate)","test_object_en":"Food E, Animal feed E, Environmental samples from cosmetics production and cosmetics trade areas E, Water E","methodology_zh":"菌落总数","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"菌落总数 平板法（倾注培养） 微生物实验室 Maków Mazowiecki E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"平板法（倾注培养）","lab_section_zh":"微生物实验室 Maków Mazowiecki"},{"_id":"6a7d76396040ebab2620d337","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Maków Mazowiecki","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Normy Procedury badawcze Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia E Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Normy Procedury badawcze","categories":["food","environment","microbiology"],"row_index":192,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Maków Mazowiecki","methodology_en":"Microorganism count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Environmental samples from food production and food trade areas E Microorganism count Plate method (pour plate) Microbiology Laboratory Maków Mazowiecki E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Plate method (pour plate)","test_object_en":"Environmental samples from food production and food trade areas E","methodology_zh":"菌落总数","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品生产与流通场所的环境样品 E 菌落总数 平板法（倾注培养） 微生物实验室 Maków Mazowiecki E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"平板法（倾注培养）","lab_section_zh":"微生物实验室 Maków Mazowiecki","test_object_zh":"食品生产与流通场所的环境样品 E"},{"_id":"6a7d76396040ebab2620d338","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Maków Mazowiecki","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym Normy Procedury badawcze Zywnosc E, Pasze dla zwierzat E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym Normy Procedury badawcze","categories":["food","microbiology"],"row_index":193,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Maków Mazowiecki","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E Presence of microorganisms Culture method with biochemical confirmation Microbiology Laboratory Maków Mazowiecki E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Culture method with biochemical confirmation","test_object_en":"Food E, Animal feed E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E 微生物的检出 培养法结合生化确认 微生物实验室 Maków Mazowiecki E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"培养法结合生化确认","methodology_zh":"微生物的检出","lab_section_zh":"微生物实验室 Maków Mazowiecki","test_object_zh":"食品 E、动物饲料 E"},{"_id":"6a7d76396040ebab2620d339","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością i kosmetykami E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Maków Mazowiecki","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością i kosmetykami E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym Normy Procedury badawcze Probki srodowiskowe z obszarow produkcji zywnosci i kosmetykow oraz obrotu zywnoscia i kosmetykami E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym Normy Procedury badawcze","categories":["food","environment","microbiology","pharma"],"row_index":194,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Maków Mazowiecki","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Environmental samples from areas of food and cosmetics production and food and cosmetics trade E Presence of microorganisms Culture method with biochemical confirmation Microbiology Laboratory Maków Mazowiecki E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Culture method with biochemical confirmation","test_object_en":"Environmental samples from areas of food and cosmetics production and food and cosmetics trade E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"来自食品与化妆品生产及食品与化妆品流通场所的环境样品 E 微生物的检出 培养法结合生化确认 微生物实验室 Maków Mazowiecki E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"培养法结合生化确认","methodology_zh":"微生物的检出","lab_section_zh":"微生物实验室 Maków Mazowiecki","test_object_zh":"来自食品与化妆品生产及食品与化妆品流通场所的环境样品 E"},{"_id":"6a7d76396040ebab2620d33a","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością i kosmetykami E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Maków Mazowiecki","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E, Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością i kosmetykami E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy Procedury badawcze Zywnosc E, Pasze dla zwierzat E, Probki srodowiskowe z obszarow produkcji zywnosci i kosmetykow oraz obrotu zywnoscia i kosmetykami E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy Procedury badawcze","categories":["food","environment","microbiology","pharma"],"row_index":195,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Maków Mazowiecki","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E, Environmental samples from areas of food and cosmetics production and food and cosmetics trade E Presence of microorganisms Culture method with biochemical and serological confirmation Microbiology Laboratory Maków Mazowiecki E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Food E, Animal feed E, Environmental samples from areas of food and cosmetics production and food and cosmetics trade E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E、来自食品与化妆品生产及食品与化妆品流通场所的环境样品 E 微生物的检出 培养法结合生化与血清学确认 微生物实验室 Maków Mazowiecki E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"培养法结合生化与血清学确认","methodology_zh":"微生物的检出","lab_section_zh":"微生物实验室 Maków Mazowiecki","test_object_zh":"食品 E、动物饲料 E、来自食品与化妆品生产及食品与化妆品流通场所的环境样品 E"},{"_id":"6a7d76396040ebab2620d33b","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Maków Mazowiecki","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym Normy Procedury badawcze Zywnosc E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym Normy Procedury badawcze","categories":["food","microbiology"],"row_index":196,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Maków Mazowiecki","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E Presence of microorganisms Culture method with biochemical and microscopic confirmation Microbiology Laboratory Maków Mazowiecki E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Culture method with biochemical and microscopic confirmation","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E 微生物的检出 培养法（附生化与显微确证） 微生物实验室 Maków Mazowiecki E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","test_object_zh":"食品 E","methodology_zh":"微生物的检出","technique_zh":"培养法（附生化与显微确证）","lab_section_zh":"微生物实验室 Maków Mazowiecki"},{"_id":"6a7d76396040ebab2620d33c","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością i kosmetykami E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Maków Mazowiecki","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością i kosmetykami E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym Normy Procedury badawcze Probki srodowiskowe z obszarow produkcji zywnosci i kosmetykow oraz obrotu zywnoscia i kosmetykami E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym Normy Procedury badawcze","categories":["food","environment","microbiology","pharma"],"row_index":197,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Maków Mazowiecki","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Environmental samples from areas of food and cosmetics production and food and cosmetics trade E Presence of microorganisms Culture method with biochemical and microscopic confirmation Microbiology Laboratory Maków Mazowiecki E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Culture method with biochemical and microscopic confirmation","test_object_en":"Environmental samples from areas of food and cosmetics production and food and cosmetics trade E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"来自食品与化妆品生产及食品与化妆品流通场所的环境样品 E 微生物的检出 培养法（附生化与显微确证） 微生物实验室 Maków Mazowiecki E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","methodology_zh":"微生物的检出","technique_zh":"培养法（附生化与显微确证）","lab_section_zh":"微生物实验室 Maków Mazowiecki","test_object_zh":"来自食品与化妆品生产及食品与化妆品流通场所的环境样品 E"},{"_id":"6a7d76396040ebab2620d33d","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana probówkowa z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana probówkowa z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana probówkowa z potwierdzeniem biochemicznym","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Maków Mazowiecki","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E Obecność drobnoustrojów\nMetoda hodowlana probówkowa z potwierdzeniem biochemicznym Normy Procedury badawcze Zywnosc E, Pasze dla zwierzat E Obecnosc drobnoustrojow\nMetoda hodowlana probowkowa z potwierdzeniem biochemicznym Normy Procedury badawcze","categories":["food","microbiology"],"row_index":198,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Maków Mazowiecki","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E Presence of microorganisms Tube culture method with biochemical confirmation Microbiology Laboratory Maków Mazowiecki E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Tube culture method with biochemical confirmation","test_object_en":"Food E, Animal feed E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E 微生物的检出 试管培养法（附生化确证） 微生物实验室 Maków Mazowiecki E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","methodology_zh":"微生物的检出","lab_section_zh":"微生物实验室 Maków Mazowiecki","technique_zh":"试管培养法（附生化确证）","test_object_zh":"食品 E、动物饲料 E"},{"_id":"6a7d76396040ebab2620d33e","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością i kosmetykami E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana probówkowa z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana probówkowa z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana probówkowa z potwierdzeniem biochemicznym","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Maków Mazowiecki","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością i kosmetykami E Obecność drobnoustrojów\nMetoda hodowlana probówkowa z potwierdzeniem biochemicznym Normy Procedury badawcze Probki srodowiskowe z obszarow produkcji zywnosci i kosmetykow oraz obrotu zywnoscia i kosmetykami E Obecnosc drobnoustrojow\nMetoda hodowlana probowkowa z potwierdzeniem biochemicznym Normy Procedury badawcze","categories":["food","environment","microbiology","pharma"],"row_index":199,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Maków Mazowiecki","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Environmental samples from areas of food and cosmetics production and food and cosmetics trade E Presence of microorganisms Tube culture method with biochemical confirmation Microbiology Laboratory Maków Mazowiecki E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Tube culture method with biochemical confirmation","test_object_en":"Environmental samples from areas of food and cosmetics production and food and cosmetics trade E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"来自食品与化妆品生产及食品与化妆品流通场所的环境样品 E 微生物的检出 试管培养法（附生化确证） 微生物实验室 Maków Mazowiecki E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","methodology_zh":"微生物的检出","lab_section_zh":"微生物实验室 Maków Mazowiecki","technique_zh":"试管培养法（附生化确证）","test_object_zh":"来自食品与化妆品生产及食品与化妆品流通场所的环境样品 E"},{"_id":"6a7d76396040ebab2620d33f","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana","techniques":["Metoda hodowlana"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Mikrobiologii Maków Mazowiecki","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Obecność drobnoustrojów\nMetoda hodowlana Procedury badawcze Zywnosc E Obecnosc drobnoustrojow\nMetoda hodowlana Procedury badawcze","categories":["food","microbiology"],"row_index":200,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Maków Mazowiecki","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E Presence of microorganisms Culture method Microbiology Laboratory Maków Mazowiecki E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Procedury badawcze","technique_en":"Culture method","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E 微生物的检出 培养法 微生物实验室 Maków Mazowiecki E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Procedury badawcze","technique_zh":"培养法","test_object_zh":"食品 E","methodology_zh":"微生物的检出","lab_section_zh":"微生物实验室 Maków Mazowiecki"},{"_id":"6a7d76396040ebab2620d340","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E","methodology":"Najbardziej prawdopodobna liczba, Escherichia coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL","reference":"PN-ISO 7251","norm_bases":["PN-ISO 7251"],"lab_section":"Pracownia Mikrobiologii Maków Mazowiecki","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL PN-ISO 7251 Zywnosc E Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL PN-ISO 7251","categories":["food","microbiology"],"row_index":201,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Maków Mazowiecki","methodology_en":"Most probable number, Escherichia coli","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E Most probable number, Escherichia coli MPN method Microbiology Laboratory Maków Mazowiecki E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. PN-ISO 7251","technique_en":"MPN method","test_object_en":"Food E","methodology_zh":"大肠埃希氏菌（Escherichia coli）最可能数（MPN）","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E 大肠埃希氏菌（Escherichia coli）最可能数（MPN） 最可能数法（MPN） 微生物实验室 Maków Mazowiecki E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 PN-ISO 7251","technique_zh":"最可能数法（MPN）","test_object_zh":"食品 E","lab_section_zh":"微生物实验室 Maków Mazowiecki"},{"_id":"6a7d76396040ebab2620d341","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Soki i koncentraty owocowe i warzywne E","methodology":"Liczba Alicyclobacillus spp. prawdopodobnie powodujące psucie","parameters":[],"technique":"Metoda filtracji membranowej z potwierdzeniem biochemicznym","techniques":["Metoda filtracji membranowej z potwierdzeniem biochemicznym"],"computed":[],"activity":"Liczba Alicyclobacillus spp. prawdopodobnie powodujące psucie\nMetoda filtracji membranowej z potwierdzeniem biochemicznym","reference":"IFU Metoda Nr 12","norm_bases":["IFU Metoda Nr 12"],"lab_section":"Pracownia Mikrobiologii Maków Mazowiecki","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Soki i koncentraty owocowe i warzywne E Liczba Alicyclobacillus spp. prawdopodobnie powodujące psucie\nMetoda filtracji membranowej z potwierdzeniem biochemicznym IFU Metoda Nr 12 Soki i koncentraty owocowe i warzywne E Liczba Alicyclobacillus spp. prawdopodobnie powodujace psucie\nMetoda filtracji membranowej z potwierdzeniem biochemicznym IFU Metoda Nr 12","categories":["other"],"row_index":202,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Maków Mazowiecki","methodology_en":"Count of Alicyclobacillus spp. potentially causing spoilage","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Fruit and vegetable juices and concentrates E Count of Alicyclobacillus spp. potentially causing spoilage Membrane filtration method with biochemical confirmation Microbiology Laboratory Maków Mazowiecki E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. IFU Metoda Nr 12","technique_en":"Membrane filtration method with biochemical confirmation","test_object_en":"Fruit and vegetable juices and concentrates E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"膜过滤法附生化确证 微生物实验室 Maków Mazowiecki E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 IFU Metoda Nr 12","lab_section_zh":"微生物实验室 Maków Mazowiecki","technique_zh":"膜过滤法附生化确证"},{"_id":"6a7d76396040ebab2620d342","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność bakterii chorobotwórczych","parameters":[],"technique":"Metoda immunoenzymatyczno fluorescencyjna (ELFA)","techniques":["Metoda immunoenzymatyczno fluorescencyjna (ELFA)"],"computed":[],"activity":"Obecność bakterii chorobotwórczych\nMetoda immunoenzymatyczno fluorescencyjna (ELFA)","reference":"PB-420","norm_bases":["PB-420"],"lab_section":"Pracownia Mikrobiologii Maków Mazowiecki","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Obecność bakterii chorobotwórczych\nMetoda immunoenzymatyczno fluorescencyjna (ELFA) PB-420 Zywnosc E Obecnosc bakterii chorobotworczych\nMetoda immunoenzymatyczno fluorescencyjna (ELFA) PB-420","categories":["food","microbiology"],"row_index":203,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Maków Mazowiecki","methodology_en":"Presence of pathogenic bacteria","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E Presence of pathogenic bacteria Enzyme-linked fluorescent immunoassay method (ELFA) Microbiology Laboratory Maków Mazowiecki E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. PB-420","technique_en":"Enzyme-linked fluorescent immunoassay method (ELFA)","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E 微生物实验室 Maków Mazowiecki E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 PB-420","test_object_zh":"食品 E","lab_section_zh":"微生物实验室 Maków Mazowiecki"},{"_id":"6a7d76396040ebab2620d343","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Próbki środowiskowe E","methodology":"Obecność bakterii chorobotwórczych","parameters":[],"technique":"Metoda immunoenzymatyczno fluorescencyjna (ELFA)","techniques":["Metoda immunoenzymatyczno fluorescencyjna (ELFA)"],"computed":[],"activity":"Obecność bakterii chorobotwórczych\nMetoda immunoenzymatyczno fluorescencyjna (ELFA)","reference":"PB-420","norm_bases":["PB-420"],"lab_section":"Pracownia Mikrobiologii Maków Mazowiecki","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Próbki środowiskowe E Obecność bakterii chorobotwórczych\nMetoda immunoenzymatyczno fluorescencyjna (ELFA) PB-420 Probki srodowiskowe E Obecnosc bakterii chorobotworczych\nMetoda immunoenzymatyczno fluorescencyjna (ELFA) PB-420","categories":["environment","microbiology"],"row_index":204,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Maków Mazowiecki","methodology_en":"Presence of pathogenic bacteria","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Environmental samples E Presence of pathogenic bacteria Enzyme-linked fluorescent immunoassay method (ELFA) Microbiology Laboratory Maków Mazowiecki E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. PB-420","technique_en":"Enzyme-linked fluorescent immunoassay method (ELFA)","test_object_en":"Environmental samples E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"微生物实验室 Maków Mazowiecki E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 PB-420","lab_section_zh":"微生物实验室 Maków Mazowiecki"},{"_id":"6a7d76396040ebab2620d344","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda filtracji membranowej","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Mikrobiologii Maków Mazowiecki","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E Liczba drobnoustrojów\nMetoda filtracji membranowej Normy Woda E Liczba drobnoustrojow\nMetoda filtracji membranowej Normy","categories":["water","microbiology"],"row_index":205,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Maków Mazowiecki","methodology_en":"Microorganism count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Water E Microorganism count Membrane filtration method Microbiology Laboratory Maków Mazowiecki E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy","technique_en":"Membrane filtration method","test_object_en":"Water E","methodology_zh":"菌落总数","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"水 E 菌落总数 膜过滤法 微生物实验室 Maków Mazowiecki E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy","technique_zh":"膜过滤法","test_object_zh":"水 E","lab_section_zh":"微生物实验室 Maków Mazowiecki"},{"_id":"6a7d76396040ebab2620d345","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt","methodology":"Liczba Listeria monocytogenes w 37°C","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba Listeria monocytogenes w 37°C\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 11290-2:2017-07","norm_bases":["PN-EN ISO 11290-2:2017-07"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt Liczba Listeria monocytogenes w 37°C\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 11290-2:2017-07 Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obrobce cieplnej, Surowe mieso i surowe produkty miesne gotowe do przygotowania (oprocz drobiu), Produkty miesne gotowe do spozycia lub gotowe do podgrzania, Surowe mieso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z miesa drobiowego gotowe do spozycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spozycia lub gotowe do podgrzania, Swieze warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboza, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowlat, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskladnikowe produkty lub elementy posilkow, Pasze i karmy dla zwierzat Liczba Listeria monocytogenes w 37°C\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 11290-2:2017-07","categories":["food","microbiology"],"row_index":206,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Listeria monocytogenes count at 37°C","search_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food Listeria monocytogenes count at 37°C Plate method (spread plate) Microbiology Laboratory Aleksandrów Łódzki PN-EN ISO 11290-2:2017-07","technique_en":"Plate method (spread plate)","test_object_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food","search_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品 平板法（表面涂布） 微生物实验室 Aleksandrów Łódzki PN-EN ISO 11290-2:2017-07","technique_zh":"平板法（表面涂布）","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","test_object_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品"},{"_id":"6a7d76396040ebab2620d346","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt","methodology":"Liczba Listeria spp. w 37°C","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba Listeria spp. w 37°C\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 11290-2:2017-07","norm_bases":["PN-EN ISO 11290-2:2017-07"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt Liczba Listeria spp. w 37°C\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 11290-2:2017-07 Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obrobce cieplnej, Surowe mieso i surowe produkty miesne gotowe do przygotowania (oprocz drobiu), Produkty miesne gotowe do spozycia lub gotowe do podgrzania, Surowe mieso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z miesa drobiowego gotowe do spozycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spozycia lub gotowe do podgrzania, Swieze warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboza, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowlat, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskladnikowe produkty lub elementy posilkow, Pasze i karmy dla zwierzat Liczba Listeria spp. w 37°C\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 11290-2:2017-07","categories":["food","microbiology"],"row_index":207,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Listeria spp. count at 37°C","search_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food Listeria spp. count at 37°C Plate method (spread plate) Microbiology Laboratory Aleksandrów Łódzki PN-EN ISO 11290-2:2017-07","technique_en":"Plate method (spread plate)","test_object_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food","search_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品 平板法（表面涂布） 微生物实验室 Aleksandrów Łódzki PN-EN ISO 11290-2:2017-07","technique_zh":"平板法（表面涂布）","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","test_object_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品"},{"_id":"6a7d76396040ebab2620d347","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt","methodology":"Liczba drobnoustrojów w 30°C","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba drobnoustrojów w 30°C\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 4833-2:2013-12 | PN-EN ISO 4833-2:2013-12/A1:2022-06","norm_bases":["PN-EN ISO 4833-2:2013-12","PN-EN ISO 4833-2:2013-12/A1:2022-06"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt Liczba drobnoustrojów w 30°C\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 4833-2:2013-12 | PN-EN ISO 4833-2:2013-12/A1:2022-06 Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obrobce cieplnej, Surowe mieso i surowe produkty miesne gotowe do przygotowania (oprocz drobiu), Produkty miesne gotowe do spozycia lub gotowe do podgrzania, Surowe mieso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z miesa drobiowego gotowe do spozycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spozycia lub gotowe do podgrzania, Swieze warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboza, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowlat, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskladnikowe produkty lub elementy posilkow, Pasze i karmy dla zwierzat Liczba drobnoustrojow w 30°C\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 4833-2:2013-12 | PN-EN ISO 4833-2:2013-12/A1:2022-06","categories":["food","microbiology"],"row_index":208,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Microorganism count at 30°C","search_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food Microorganism count at 30°C Plate method (spread plate) Microbiology Laboratory Aleksandrów Łódzki PN-EN ISO 4833-2:2013-12 | PN-EN ISO 4833-2:2013-12/A1:2022-06","technique_en":"Plate method (spread plate)","test_object_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food","search_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品 30°C 微生物数 平板法（表面涂布） 微生物实验室 Aleksandrów Łódzki PN-EN ISO 4833-2:2013-12 | PN-EN ISO 4833-2:2013-12/A1:2022-06","technique_zh":"平板法（表面涂布）","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","test_object_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品","methodology_zh":"30°C 微生物数"},{"_id":"6a7d76396040ebab2620d348","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt","methodology":"Liczba gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków) w 37°C","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków) w 37°C\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 6888-1:2022-03 | PN-EN ISO 6888-1:2022-3/A1:2024-02","norm_bases":["PN-EN ISO 6888-1:2022-03","PN-EN ISO 6888-1:2022-3/A1:2024-02"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt Liczba gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków) w 37°C\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 6888-1:2022-03 | PN-EN ISO 6888-1:2022-3/A1:2024-02 Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obrobce cieplnej, Surowe mieso i surowe produkty miesne gotowe do przygotowania (oprocz drobiu), Produkty miesne gotowe do spozycia lub gotowe do podgrzania, Surowe mieso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z miesa drobiowego gotowe do spozycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spozycia lub gotowe do podgrzania, Swieze warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboza, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowlat, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskladnikowe produkty lub elementy posilkow, Pasze i karmy dla zwierzat Liczba gronkowcow koagulazo-dodatnich (Staphylococcus aureus i innych gatunkow) w 37°C\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 6888-1:2022-03 | PN-EN ISO 6888-1:2022-3/A1:2024-02","categories":["food"],"row_index":209,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Count of coagulase-positive staphylococci (Staphylococcus aureus and other species) at 37°C","search_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food Count of coagulase-positive staphylococci (Staphylococcus aureus and other species) at 37°C Plate method (spread plate) Microbiology Laboratory Aleksandrów Łódzki PN-EN ISO 6888-1:2022-03 | PN-EN ISO 6888-1:2022-3/A1:2024-02","technique_en":"Plate method (spread plate)","test_object_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food","search_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品 平板法（表面涂布） 微生物实验室 Aleksandrów Łódzki PN-EN ISO 6888-1:2022-03 | PN-EN ISO 6888-1:2022-3/A1:2024-02","technique_zh":"平板法（表面涂布）","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","test_object_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品"},{"_id":"6a7d76396040ebab2620d349","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt","methodology":"Liczba przypuszczalnych, Bacillus cereus w 30°C","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba przypuszczalnych, Bacillus cereus w 30°C\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 7932:2005 | PN-EN ISO 7932:2005/A1:2020-09","norm_bases":["PN-EN ISO 7932:2005","PN-EN ISO 7932:2005/A1:2020-09"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt Liczba przypuszczalnych, Bacillus cereus w 30°C\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 7932:2005 | PN-EN ISO 7932:2005/A1:2020-09 Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obrobce cieplnej, Surowe mieso i surowe produkty miesne gotowe do przygotowania (oprocz drobiu), Produkty miesne gotowe do spozycia lub gotowe do podgrzania, Surowe mieso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z miesa drobiowego gotowe do spozycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spozycia lub gotowe do podgrzania, Swieze warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboza, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowlat, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskladnikowe produkty lub elementy posilkow, Pasze i karmy dla zwierzat Liczba przypuszczalnych, Bacillus cereus w 30°C\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 7932:2005 | PN-EN ISO 7932:2005/A1:2020-09","categories":["food"],"row_index":210,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Presumptive count of, Bacillus cereus at 30°C","search_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food Presumptive count of, Bacillus cereus at 30°C Plate method (spread plate) Microbiology Laboratory Aleksandrów Łódzki PN-EN ISO 7932:2005 | PN-EN ISO 7932:2005/A1:2020-09","technique_en":"Plate method (spread plate)","test_object_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food","search_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品 平板法（表面涂布） 微生物实验室 Aleksandrów Łódzki PN-EN ISO 7932:2005 | PN-EN ISO 7932:2005/A1:2020-09","technique_zh":"平板法（表面涂布）","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","test_object_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品"},{"_id":"6a7d76396040ebab2620d34a","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt","methodology":"Liczba przypuszczalnych, Pseudomonas spp. w 25°C","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba przypuszczalnych, Pseudomonas spp. w 25°C\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 13720:2010","norm_bases":["PN-EN ISO 13720:2010"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt Liczba przypuszczalnych, Pseudomonas spp. w 25°C\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 13720:2010 Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obrobce cieplnej, Surowe mieso i surowe produkty miesne gotowe do przygotowania (oprocz drobiu), Produkty miesne gotowe do spozycia lub gotowe do podgrzania, Surowe mieso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z miesa drobiowego gotowe do spozycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spozycia lub gotowe do podgrzania, Swieze warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboza, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowlat, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskladnikowe produkty lub elementy posilkow, Pasze i karmy dla zwierzat Liczba przypuszczalnych, Pseudomonas spp. w 25°C\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 13720:2010","categories":["food"],"row_index":211,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Presumptive count of, Pseudomonas spp. at 25°C","search_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food Presumptive count of, Pseudomonas spp. at 25°C Plate method (spread plate) Microbiology Laboratory Aleksandrów Łódzki PN-EN ISO 13720:2010","technique_en":"Plate method (spread plate)","test_object_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food","search_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品 平板法（表面涂布） 微生物实验室 Aleksandrów Łódzki PN-EN ISO 13720:2010","technique_zh":"平板法（表面涂布）","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","test_object_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品"},{"_id":"6a7d76396040ebab2620d34b","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt","methodology":"Liczba drożdży i pleśni w produktach o aktywności wody wyższej niż 0,95","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba drożdży i pleśni w produktach o aktywności wody wyższej niż 0,95\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-ISO 21527-1:2009","norm_bases":["PN-ISO 21527-1:2009"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt Liczba drożdży i pleśni w produktach o aktywności wody wyższej niż 0,95\nMetoda płytkowa (posiew powierzchniowy) PN-ISO 21527-1:2009 Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obrobce cieplnej, Surowe mieso i surowe produkty miesne gotowe do przygotowania (oprocz drobiu), Produkty miesne gotowe do spozycia lub gotowe do podgrzania, Surowe mieso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z miesa drobiowego gotowe do spozycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spozycia lub gotowe do podgrzania, Swieze warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboza, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowlat, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskladnikowe produkty lub elementy posilkow, Pasze i karmy dla zwierzat Liczba drozdzy i plesni w produktach o aktywnosci wody wyzszej niz 0,95\nMetoda plytkowa (posiew powierzchniowy) PN-ISO 21527-1:2009","categories":["food","water"],"row_index":212,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Yeast and mould count in products with water activity greater than 0,95","search_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food Yeast and mould count in products with water activity greater than 0,95 Plate method (spread plate) Microbiology Laboratory Aleksandrów Łódzki PN-ISO 21527-1:2009","technique_en":"Plate method (spread plate)","test_object_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food","search_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品 水分活度高于 0,95 产品中的酵母与霉菌数 平板法（表面涂布） 微生物实验室 Aleksandrów Łódzki PN-ISO 21527-1:2009","technique_zh":"平板法（表面涂布）","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","test_object_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品","methodology_zh":"水分活度高于 0,95 产品中的酵母与霉菌数"},{"_id":"6a7d76396040ebab2620d34c","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt","methodology":"Liczba drożdży i pleśni w produktach o aktywności wody niższej lub równej 0,95","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba drożdży i pleśni w produktach o aktywności wody niższej lub równej 0,95\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-ISO 21527-2:2009","norm_bases":["PN-ISO 21527-2:2009"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt Liczba drożdży i pleśni w produktach o aktywności wody niższej lub równej 0,95\nMetoda płytkowa (posiew powierzchniowy) PN-ISO 21527-2:2009 Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obrobce cieplnej, Surowe mieso i surowe produkty miesne gotowe do przygotowania (oprocz drobiu), Produkty miesne gotowe do spozycia lub gotowe do podgrzania, Surowe mieso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z miesa drobiowego gotowe do spozycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spozycia lub gotowe do podgrzania, Swieze warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboza, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowlat, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskladnikowe produkty lub elementy posilkow, Pasze i karmy dla zwierzat Liczba drozdzy i plesni w produktach o aktywnosci wody nizszej lub rownej 0,95\nMetoda plytkowa (posiew powierzchniowy) PN-ISO 21527-2:2009","categories":["food","water"],"row_index":213,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Yeast and mould count in products with water activity less than or equal to 0,95","search_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food Yeast and mould count in products with water activity less than or equal to 0,95 Plate method (spread plate) Microbiology Laboratory Aleksandrów Łódzki PN-ISO 21527-2:2009","technique_en":"Plate method (spread plate)","test_object_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food","search_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品 水分活度低于或等于 0,95 产品中的酵母与霉菌数 平板法（表面涂布） 微生物实验室 Aleksandrów Łódzki PN-ISO 21527-2:2009","technique_zh":"平板法（表面涂布）","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","test_object_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品","methodology_zh":"水分活度低于或等于 0,95 产品中的酵母与霉菌数"},{"_id":"6a7d76396040ebab2620d34d","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt","methodology":"Liczba gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków) w 37°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków) w 37°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6888-2:2022-03 | PN-EN ISO 6888-2:2022-03/A1:2024-02","norm_bases":["PN-EN ISO 6888-2:2022-03","PN-EN ISO 6888-2:2022-03/A1:2024-02"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt Liczba gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków) w 37°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6888-2:2022-03 | PN-EN ISO 6888-2:2022-03/A1:2024-02 Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obrobce cieplnej, Surowe mieso i surowe produkty miesne gotowe do przygotowania (oprocz drobiu), Produkty miesne gotowe do spozycia lub gotowe do podgrzania, Surowe mieso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z miesa drobiowego gotowe do spozycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spozycia lub gotowe do podgrzania, Swieze warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboza, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowlat, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskladnikowe produkty lub elementy posilkow, Pasze i karmy dla zwierzat Liczba gronkowcow koagulazo-dodatnich (Staphylococcus aureus i innych gatunkow) w 37°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6888-2:2022-03 | PN-EN ISO 6888-2:2022-03/A1:2024-02","categories":["food"],"row_index":214,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Count of coagulase-positive staphylococci (Staphylococcus aureus and other species) at 37°C","search_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food Count of coagulase-positive staphylococci (Staphylococcus aureus and other species) at 37°C Plate method (pour plate) Microbiology Laboratory Aleksandrów Łódzki PN-EN ISO 6888-2:2022-03 | PN-EN ISO 6888-2:2022-03/A1:2024-02","technique_en":"Plate method (pour plate)","test_object_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food","search_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品 平板法（倾注培养） 微生物实验室 Aleksandrów Łódzki PN-EN ISO 6888-2:2022-03 | PN-EN ISO 6888-2:2022-03/A1:2024-02","technique_zh":"平板法（倾注培养）","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","test_object_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品"},{"_id":"6a7d76396040ebab2620d34e","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt","methodology":"Liczba drobnoustrojów w 30°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów w 30°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 4833-1:2013-12 | PN-EN ISO 4833-1:2013-12/A1:2022-06","norm_bases":["PN-EN ISO 4833-1:2013-12","PN-EN ISO 4833-1:2013-12/A1:2022-06"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt Liczba drobnoustrojów w 30°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 4833-1:2013-12 | PN-EN ISO 4833-1:2013-12/A1:2022-06 Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obrobce cieplnej, Surowe mieso i surowe produkty miesne gotowe do przygotowania (oprocz drobiu), Produkty miesne gotowe do spozycia lub gotowe do podgrzania, Surowe mieso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z miesa drobiowego gotowe do spozycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spozycia lub gotowe do podgrzania, Swieze warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboza, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowlat, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskladnikowe produkty lub elementy posilkow, Pasze i karmy dla zwierzat Liczba drobnoustrojow w 30°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 4833-1:2013-12 | PN-EN ISO 4833-1:2013-12/A1:2022-06","categories":["food","microbiology"],"row_index":215,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Microorganism count at 30°C","search_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food Microorganism count at 30°C Plate method (pour plate) Microbiology Laboratory Aleksandrów Łódzki PN-EN ISO 4833-1:2013-12 | PN-EN ISO 4833-1:2013-12/A1:2022-06","technique_en":"Plate method (pour plate)","test_object_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food","search_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品 30°C 微生物数 平板法（倾注培养） 微生物实验室 Aleksandrów Łódzki PN-EN ISO 4833-1:2013-12 | PN-EN ISO 4833-1:2013-12/A1:2022-06","technique_zh":"平板法（倾注培养）","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","test_object_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品","methodology_zh":"30°C 微生物数"},{"_id":"6a7d76396040ebab2620d34f","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt","methodology":"Liczba drożdży i pleśni w produktach o aktywności wody wyższej niż 0,95","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drożdży i pleśni w produktach o aktywności wody wyższej niż 0,95\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 21527-1:2009","norm_bases":["PN-ISO 21527-1:2009"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt Liczba drożdży i pleśni w produktach o aktywności wody wyższej niż 0,95\nMetoda płytkowa (posiew wgłębny) PN-ISO 21527-1:2009 Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obrobce cieplnej, Surowe mieso i surowe produkty miesne gotowe do przygotowania (oprocz drobiu), Produkty miesne gotowe do spozycia lub gotowe do podgrzania, Surowe mieso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z miesa drobiowego gotowe do spozycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spozycia lub gotowe do podgrzania, Swieze warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboza, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowlat, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskladnikowe produkty lub elementy posilkow, Pasze i karmy dla zwierzat Liczba drozdzy i plesni w produktach o aktywnosci wody wyzszej niz 0,95\nMetoda plytkowa (posiew wglebny) PN-ISO 21527-1:2009","categories":["food","water"],"row_index":216,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Yeast and mould count in products with water activity greater than 0,95","search_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food Yeast and mould count in products with water activity greater than 0,95 Plate method (pour plate) Microbiology Laboratory Aleksandrów Łódzki PN-ISO 21527-1:2009","technique_en":"Plate method (pour plate)","test_object_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food","search_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品 水分活度高于 0,95 产品中的酵母与霉菌数 平板法（倾注培养） 微生物实验室 Aleksandrów Łódzki PN-ISO 21527-1:2009","technique_zh":"平板法（倾注培养）","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","test_object_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品","methodology_zh":"水分活度高于 0,95 产品中的酵母与霉菌数"},{"_id":"6a7d76396040ebab2620d350","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt","methodology":"Liczba drożdży i pleśni w produktach o aktywności wody niższej lub równej 0,95","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drożdży i pleśni w produktach o aktywności wody niższej lub równej 0,95\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 21527-2:2009","norm_bases":["PN-ISO 21527-2:2009"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt Liczba drożdży i pleśni w produktach o aktywności wody niższej lub równej 0,95\nMetoda płytkowa (posiew wgłębny) PN-ISO 21527-2:2009 Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obrobce cieplnej, Surowe mieso i surowe produkty miesne gotowe do przygotowania (oprocz drobiu), Produkty miesne gotowe do spozycia lub gotowe do podgrzania, Surowe mieso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z miesa drobiowego gotowe do spozycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spozycia lub gotowe do podgrzania, Swieze warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboza, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowlat, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskladnikowe produkty lub elementy posilkow, Pasze i karmy dla zwierzat Liczba drozdzy i plesni w produktach o aktywnosci wody nizszej lub rownej 0,95\nMetoda plytkowa (posiew wglebny) PN-ISO 21527-2:2009","categories":["food","water"],"row_index":217,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Yeast and mould count in products with water activity less than or equal to 0,95","search_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food Yeast and mould count in products with water activity less than or equal to 0,95 Plate method (pour plate) Microbiology Laboratory Aleksandrów Łódzki PN-ISO 21527-2:2009","technique_en":"Plate method (pour plate)","test_object_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food","search_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品 水分活度低于或等于 0,95 产品中的酵母与霉菌数 平板法（倾注培养） 微生物实验室 Aleksandrów Łódzki PN-ISO 21527-2:2009","technique_zh":"平板法（倾注培养）","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","test_object_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品","methodology_zh":"水分活度低于或等于 0,95 产品中的酵母与霉菌数"},{"_id":"6a7d76396040ebab2620d351","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt","methodology":"Liczba drożdży i pleśni w 25°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drożdży i pleśni w 25°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 7954:1999","norm_bases":["PN-ISO 7954:1999"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt Liczba drożdży i pleśni w 25°C\nMetoda płytkowa (posiew wgłębny) PN-ISO 7954:1999 Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obrobce cieplnej, Surowe mieso i surowe produkty miesne gotowe do przygotowania (oprocz drobiu), Produkty miesne gotowe do spozycia lub gotowe do podgrzania, Surowe mieso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z miesa drobiowego gotowe do spozycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spozycia lub gotowe do podgrzania, Swieze warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboza, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowlat, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskladnikowe produkty lub elementy posilkow, Pasze i karmy dla zwierzat Liczba drozdzy i plesni w 25°C\nMetoda plytkowa (posiew wglebny) PN-ISO 7954:1999","categories":["food"],"row_index":218,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Yeast and mould count at 25°C","search_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food Yeast and mould count at 25°C Plate method (pour plate) Microbiology Laboratory Aleksandrów Łódzki PN-ISO 7954:1999","technique_en":"Plate method (pour plate)","test_object_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food","search_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品 平板法（倾注培养） 微生物实验室 Aleksandrów Łódzki PN-ISO 7954:1999","technique_zh":"平板法（倾注培养）","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","test_object_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品"},{"_id":"6a7d76396040ebab2620d352","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt","methodology":"Liczba bakterii z grupy coli w 30°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba bakterii z grupy coli w 30°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 4832:2007","norm_bases":["PN-ISO 4832:2007"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt Liczba bakterii z grupy coli w 30°C\nMetoda płytkowa (posiew wgłębny) PN-ISO 4832:2007 Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obrobce cieplnej, Surowe mieso i surowe produkty miesne gotowe do przygotowania (oprocz drobiu), Produkty miesne gotowe do spozycia lub gotowe do podgrzania, Surowe mieso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z miesa drobiowego gotowe do spozycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spozycia lub gotowe do podgrzania, Swieze warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboza, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowlat, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskladnikowe produkty lub elementy posilkow, Pasze i karmy dla zwierzat Liczba bakterii z grupy coli w 30°C\nMetoda plytkowa (posiew wglebny) PN-ISO 4832:2007","categories":["food","microbiology"],"row_index":219,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Coliform bacteria count at 30°C","search_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food Coliform bacteria count at 30°C Plate method (pour plate) Microbiology Laboratory Aleksandrów Łódzki PN-ISO 4832:2007","technique_en":"Plate method (pour plate)","test_object_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food","search_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品 平板法（倾注培养） 微生物实验室 Aleksandrów Łódzki PN-ISO 4832:2007","technique_zh":"平板法（倾注培养）","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","test_object_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品"},{"_id":"6a7d76396040ebab2620d353","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt","methodology":"Liczba bakterii z grupy coli w 37°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba bakterii z grupy coli w 37°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 4832:2007","norm_bases":["PN-ISO 4832:2007"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt Liczba bakterii z grupy coli w 37°C\nMetoda płytkowa (posiew wgłębny) PN-ISO 4832:2007 Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obrobce cieplnej, Surowe mieso i surowe produkty miesne gotowe do przygotowania (oprocz drobiu), Produkty miesne gotowe do spozycia lub gotowe do podgrzania, Surowe mieso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z miesa drobiowego gotowe do spozycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spozycia lub gotowe do podgrzania, Swieze warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboza, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowlat, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskladnikowe produkty lub elementy posilkow, Pasze i karmy dla zwierzat Liczba bakterii z grupy coli w 37°C\nMetoda plytkowa (posiew wglebny) PN-ISO 4832:2007","categories":["food","microbiology"],"row_index":220,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Coliform bacteria count at 37°C","search_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food Coliform bacteria count at 37°C Plate method (pour plate) Microbiology Laboratory Aleksandrów Łódzki PN-ISO 4832:2007","technique_en":"Plate method (pour plate)","test_object_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food","search_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品 平板法（倾注培养） 微生物实验室 Aleksandrów Łódzki PN-ISO 4832:2007","technique_zh":"平板法（倾注培养）","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","test_object_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品"},{"_id":"6a7d76396040ebab2620d354","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt","methodology":"Liczba beta-glukuronidazododatnich, Escherichia coli w 44°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba beta-glukuronidazododatnich, Escherichia coli w 44°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 16649-2:2004","norm_bases":["PN-ISO 16649-2:2004"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt Liczba beta-glukuronidazododatnich, Escherichia coli w 44°C\nMetoda płytkowa (posiew wgłębny) PN-ISO 16649-2:2004 Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obrobce cieplnej, Surowe mieso i surowe produkty miesne gotowe do przygotowania (oprocz drobiu), Produkty miesne gotowe do spozycia lub gotowe do podgrzania, Surowe mieso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z miesa drobiowego gotowe do spozycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spozycia lub gotowe do podgrzania, Swieze warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboza, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowlat, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskladnikowe produkty lub elementy posilkow, Pasze i karmy dla zwierzat Liczba beta-glukuronidazododatnich, Escherichia coli w 44°C\nMetoda plytkowa (posiew wglebny) PN-ISO 16649-2:2004","categories":["food","microbiology"],"row_index":221,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Count of beta-glucuronidase-positive, Escherichia coli at 44°C","search_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food Count of beta-glucuronidase-positive, Escherichia coli at 44°C Plate method (pour plate) Microbiology Laboratory Aleksandrów Łódzki PN-ISO 16649-2:2004","technique_en":"Plate method (pour plate)","test_object_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food","search_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品 平板法（倾注培养） 微生物实验室 Aleksandrów Łódzki PN-ISO 16649-2:2004","technique_zh":"平板法（倾注培养）","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","test_object_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品"},{"_id":"6a7d76396040ebab2620d355","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt","methodology":"Liczba Enterobacteriaceae w 37°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba Enterobacteriaceae w 37°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 21528-2:2017-08","norm_bases":["PN-EN ISO 21528-2:2017-08"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt Liczba Enterobacteriaceae w 37°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 21528-2:2017-08 Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obrobce cieplnej, Surowe mieso i surowe produkty miesne gotowe do przygotowania (oprocz drobiu), Produkty miesne gotowe do spozycia lub gotowe do podgrzania, Surowe mieso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z miesa drobiowego gotowe do spozycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spozycia lub gotowe do podgrzania, Swieze warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboza, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowlat, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskladnikowe produkty lub elementy posilkow, Pasze i karmy dla zwierzat Liczba Enterobacteriaceae w 37°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 21528-2:2017-08","categories":["food"],"row_index":222,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Enterobacteriaceae count at 37°C","search_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food Enterobacteriaceae count at 37°C Plate method (pour plate) Microbiology Laboratory Aleksandrów Łódzki PN-EN ISO 21528-2:2017-08","technique_en":"Plate method (pour plate)","test_object_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food","search_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品 37°C 肠杆菌科计数 平板法（倾注培养） 微生物实验室 Aleksandrów Łódzki PN-EN ISO 21528-2:2017-08","technique_zh":"平板法（倾注培养）","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","test_object_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品","methodology_zh":"37°C 肠杆菌科计数"},{"_id":"6a7d76396040ebab2620d356","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt","methodology":"Obecność bakterii z grupy coli","parameters":[],"technique":"Metoda hodowlana probówkowa","techniques":["Metoda hodowlana probówkowa"],"computed":[],"activity":"Obecność bakterii z grupy coli\nMetoda hodowlana probówkowa","reference":"PN-ISO 4831:2007","norm_bases":["PN-ISO 4831:2007"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt Obecność bakterii z grupy coli\nMetoda hodowlana probówkowa PN-ISO 4831:2007 Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obrobce cieplnej, Surowe mieso i surowe produkty miesne gotowe do przygotowania (oprocz drobiu), Produkty miesne gotowe do spozycia lub gotowe do podgrzania, Surowe mieso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z miesa drobiowego gotowe do spozycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spozycia lub gotowe do podgrzania, Swieze warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboza, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowlat, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskladnikowe produkty lub elementy posilkow, Pasze i karmy dla zwierzat Obecnosc bakterii z grupy coli\nMetoda hodowlana probowkowa PN-ISO 4831:2007","categories":["food","microbiology"],"row_index":223,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Presence of coliform bacteria","search_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food Presence of coliform bacteria Tube culture method Microbiology Laboratory Aleksandrów Łódzki PN-ISO 4831:2007","technique_en":"Tube culture method","test_object_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","search_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品 大肠菌群的检出 试管培养法 微生物实验室 Aleksandrów Łódzki PN-ISO 4831:2007","methodology_zh":"大肠菌群的检出","technique_zh":"试管培养法","test_object_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品"},{"_id":"6a7d76396040ebab2620d357","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Mieszanki dla niemowląt","methodology":"Liczba Enterobacteriaceae w 30°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba Enterobacteriaceae w 30°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 21528-2:2017-08 IT-12/LAM wyd. 1 z dn. 09.12.2025","norm_bases":["PN-EN ISO 21528-2:2017-08 IT-12/LAM wyd. 1 z dn. 09.12.2025"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Mieszanki dla niemowląt Liczba Enterobacteriaceae w 30°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 21528-2:2017-08 IT-12/LAM wyd. 1 z dn. 09.12.2025 Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obrobce cieplnej, Mieszanki dla niemowlat Liczba Enterobacteriaceae w 30°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 21528-2:2017-08 IT-12/LAM wyd. 1 z dn. 09.12.2025","categories":["food"],"row_index":224,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Enterobacteriaceae count at 30°C","search_en":"Raw milk and raw milk products, Heat-treated milk and milk products, Infant formulae Enterobacteriaceae count at 30°C Plate method (pour plate) Microbiology Laboratory Aleksandrów Łódzki PN-EN ISO 21528-2:2017-08 IT-12/LAM wyd. 1 z dn. 09.12.2025","technique_en":"Plate method (pour plate)","test_object_en":"Raw milk and raw milk products, Heat-treated milk and milk products, Infant formulae","search_zh":"平板法（倾注培养） 微生物实验室 Aleksandrów Łódzki PN-EN ISO 21528-2:2017-08 IT-12/LAM wyd. 1 z dn. 09.12.2025","technique_zh":"平板法（倾注培养）","lab_section_zh":"微生物实验室 Aleksandrów Łódzki"},{"_id":"6a7d76396040ebab2620d358","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt","methodology":"Obecność Enterobacteriaceae","parameters":[],"technique":"Metoda hodowlana probówkowa z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana probówkowa z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Enterobacteriaceae\nMetoda hodowlana probówkowa z potwierdzeniem biochemicznym","reference":"PN-EN ISO 21528-1:2017-08","norm_bases":["PN-EN ISO 21528-1:2017-08"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt Obecność Enterobacteriaceae\nMetoda hodowlana probówkowa z potwierdzeniem biochemicznym PN-EN ISO 21528-1:2017-08 Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obrobce cieplnej, Surowe mieso i surowe produkty miesne gotowe do przygotowania (oprocz drobiu), Produkty miesne gotowe do spozycia lub gotowe do podgrzania, Surowe mieso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z miesa drobiowego gotowe do spozycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spozycia lub gotowe do podgrzania, Swieze warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboza, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowlat, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskladnikowe produkty lub elementy posilkow, Pasze i karmy dla zwierzat Obecnosc Enterobacteriaceae\nMetoda hodowlana probowkowa z potwierdzeniem biochemicznym PN-EN ISO 21528-1:2017-08","categories":["food"],"row_index":225,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Presence of Enterobacteriaceae","search_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food Presence of Enterobacteriaceae Tube culture method with biochemical confirmation Microbiology Laboratory Aleksandrów Łódzki PN-EN ISO 21528-1:2017-08","technique_en":"Tube culture method with biochemical confirmation","test_object_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","search_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品 肠杆菌科的检出 试管培养法（附生化确证） 微生物实验室 Aleksandrów Łódzki PN-EN ISO 21528-1:2017-08","test_object_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品","methodology_zh":"肠杆菌科的检出","technique_zh":"试管培养法（附生化确证）"},{"_id":"6a7d76396040ebab2620d359","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt","methodology":"Obecność gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków)","parameters":[],"technique":"Metoda hodowlana probówkowa z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana probówkowa z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków)\nMetoda hodowlana probówkowa z potwierdzeniem biochemicznym","reference":"PN-EN ISO 6888-3:2004 | PN-EN ISO 6888-3:2004/AC:2005","norm_bases":["PN-EN ISO 6888-3:2004","PN-EN ISO 6888-3:2004/AC:2005"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt Obecność gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków)\nMetoda hodowlana probówkowa z potwierdzeniem biochemicznym PN-EN ISO 6888-3:2004 | PN-EN ISO 6888-3:2004/AC:2005 Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obrobce cieplnej, Surowe mieso i surowe produkty miesne gotowe do przygotowania (oprocz drobiu), Produkty miesne gotowe do spozycia lub gotowe do podgrzania, Surowe mieso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z miesa drobiowego gotowe do spozycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spozycia lub gotowe do podgrzania, Swieze warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboza, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowlat, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskladnikowe produkty lub elementy posilkow, Pasze i karmy dla zwierzat Obecnosc gronkowcow koagulazo-dodatnich (Staphylococcus aureus i innych gatunkow)\nMetoda hodowlana probowkowa z potwierdzeniem biochemicznym PN-EN ISO 6888-3:2004 | PN-EN ISO 6888-3:2004/AC:2005","categories":["food"],"row_index":226,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Presence of coagulase-positive staphylococci (Staphylococcus aureus and other species)","search_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food Presence of coagulase-positive staphylococci (Staphylococcus aureus and other species) Tube culture method with biochemical confirmation Microbiology Laboratory Aleksandrów Łódzki PN-EN ISO 6888-3:2004 | PN-EN ISO 6888-3:2004/AC:2005","technique_en":"Tube culture method with biochemical confirmation","test_object_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","search_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品 凝固酶阳性葡萄球菌（金黄色葡萄球菌及其他菌种）的检出 试管培养法（附生化确证） 微生物实验室 Aleksandrów Łódzki PN-EN ISO 6888-3:2004 | PN-EN ISO 6888-3:2004/AC:2005","test_object_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品","technique_zh":"试管培养法（附生化确证）","methodology_zh":"凝固酶阳性葡萄球菌（金黄色葡萄球菌及其他菌种）的检出"},{"_id":"6a7d76396040ebab2620d35a","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt","methodology":"Obecność Escherichia coli","parameters":[],"technique":"Metoda hodowlana probówkowa z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana probówkowa z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Escherichia coli\nMetoda hodowlana probówkowa z potwierdzeniem biochemicznym","reference":"PN-ISO 7251:2006","norm_bases":["PN-ISO 7251:2006"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt Obecność Escherichia coli\nMetoda hodowlana probówkowa z potwierdzeniem biochemicznym PN-ISO 7251:2006 Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obrobce cieplnej, Surowe mieso i surowe produkty miesne gotowe do przygotowania (oprocz drobiu), Produkty miesne gotowe do spozycia lub gotowe do podgrzania, Surowe mieso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z miesa drobiowego gotowe do spozycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spozycia lub gotowe do podgrzania, Swieze warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboza, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowlat, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskladnikowe produkty lub elementy posilkow, Pasze i karmy dla zwierzat Obecnosc Escherichia coli\nMetoda hodowlana probowkowa z potwierdzeniem biochemicznym PN-ISO 7251:2006","categories":["food","microbiology"],"row_index":227,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Presence of Escherichia coli","search_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food Presence of Escherichia coli Tube culture method with biochemical confirmation Microbiology Laboratory Aleksandrów Łódzki PN-ISO 7251:2006","technique_en":"Tube culture method with biochemical confirmation","test_object_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food","methodology_zh":"大肠埃希氏菌（Escherichia coli）检出","search_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品 大肠埃希氏菌（Escherichia coli）检出 试管培养法（附生化确证） 微生物实验室 Aleksandrów Łódzki PN-ISO 7251:2006","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","test_object_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品","technique_zh":"试管培养法（附生化确证）"},{"_id":"6a7d76396040ebab2620d35b","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt","methodology":"Obecność Listeria monocytogenes","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 11290-1:2017-07","norm_bases":["PN-EN ISO 11290-1:2017-07"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt Obecność Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290-1:2017-07 Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obrobce cieplnej, Surowe mieso i surowe produkty miesne gotowe do przygotowania (oprocz drobiu), Produkty miesne gotowe do spozycia lub gotowe do podgrzania, Surowe mieso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z miesa drobiowego gotowe do spozycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spozycia lub gotowe do podgrzania, Swieze warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboza, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowlat, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskladnikowe produkty lub elementy posilkow, Pasze i karmy dla zwierzat Obecnosc Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290-1:2017-07","categories":["food","microbiology"],"row_index":228,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Presence of Listeria monocytogenes","search_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food Presence of Listeria monocytogenes Culture method with biochemical confirmation Microbiology Laboratory Aleksandrów Łódzki PN-EN ISO 11290-1:2017-07","technique_en":"Culture method with biochemical confirmation","test_object_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food","search_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品 单核细胞增生李斯特氏菌的检出 培养法结合生化确认 微生物实验室 Aleksandrów Łódzki PN-EN ISO 11290-1:2017-07","technique_zh":"培养法结合生化确认","methodology_zh":"单核细胞增生李斯特氏菌的检出","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","test_object_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品"},{"_id":"6a7d76396040ebab2620d35c","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt","methodology":"Obecność Listeria spp.","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Listeria spp.\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 11290-1:2017-07","norm_bases":["PN-EN ISO 11290-1:2017-07"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt Obecność Listeria spp.\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290-1:2017-07 Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obrobce cieplnej, Surowe mieso i surowe produkty miesne gotowe do przygotowania (oprocz drobiu), Produkty miesne gotowe do spozycia lub gotowe do podgrzania, Surowe mieso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z miesa drobiowego gotowe do spozycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spozycia lub gotowe do podgrzania, Swieze warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboza, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowlat, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskladnikowe produkty lub elementy posilkow, Pasze i karmy dla zwierzat Obecnosc Listeria spp.\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290-1:2017-07","categories":["food","microbiology"],"row_index":229,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Presence of Listeria spp.","search_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food Presence of Listeria spp. Culture method with biochemical confirmation Microbiology Laboratory Aleksandrów Łódzki PN-EN ISO 11290-1:2017-07","technique_en":"Culture method with biochemical confirmation","test_object_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food","search_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品 李斯特氏菌属（Listeria spp.）的检出 培养法结合生化确认 微生物实验室 Aleksandrów Łódzki PN-EN ISO 11290-1:2017-07","technique_zh":"培养法结合生化确认","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","test_object_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品","methodology_zh":"李斯特氏菌属（Listeria spp.）的检出"},{"_id":"6a7d76396040ebab2620d35d","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt","methodology":"Obecność bakterii z rodzaju, Salmonella spp.","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność bakterii z rodzaju, Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020-09","norm_bases":["PN-EN ISO 6579-1:2017-04","PN-EN ISO 6579-1:2017-04/A1:2020-09"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obróbce cieplnej, Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskładnikowe produkty lub elementy posiłków, Pasze i karmy dla zwierząt Obecność bakterii z rodzaju, Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020-09 Surowe mleko i produkty z mleka surowego, Mleko i produkty mleczne poddane obrobce cieplnej, Surowe mieso i surowe produkty miesne gotowe do przygotowania (oprocz drobiu), Produkty miesne gotowe do spozycia lub gotowe do podgrzania, Surowe mieso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z miesa drobiowego gotowe do spozycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spozycia lub gotowe do podgrzania, Swieze warzywa i owoce, Przetworzone owoce i warzywa, Suszone zboza, owoce, orzechy, nasiona i warzywa, Mieszanki dla niemowlat, Czekolada, wyroby piekarnicze i cukiernicze, Wieloskladnikowe produkty lub elementy posilkow, Pasze i karmy dla zwierzat Obecnosc bakterii z rodzaju, Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020-09","categories":["food","microbiology"],"row_index":230,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Presence of bacteria of the genus, Salmonella spp.","search_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food Presence of bacteria of the genus, Salmonella spp. Culture method with biochemical and serological confirmation Microbiology Laboratory Aleksandrów Łódzki PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020-09","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Raw milk and raw milk products, Heat-treated milk and dairy products, Raw meat and raw meat products ready to be prepared (except poultry), Meat products ready to eat or ready to be reheated, Raw poultry meat and raw poultry products ready to be prepared, Poultry meat products ready to eat or ready to be reheated, Eggs and egg products (derivatives), Raw fish and seafood ready to be prepared, Fish products and seafood ready to eat or ready to be reheated, Fresh vegetables and fruit, Processed fruit and vegetables, Dried cereals, fruit, nuts, seeds and vegetables, Infant formulae, Chocolate, bakery and confectionery products, Multi-ingredient products or meal components, Feed and pet food","search_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品 培养法结合生化与血清学确认 微生物实验室 Aleksandrów Łódzki PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020-09","technique_zh":"培养法结合生化与血清学确认","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","test_object_zh":"生鲜乳与生鲜乳制品、热处理乳与乳制品、可供制备的生鲜肉与生鲜肉制品（禽肉除外）、即食或即热肉制品、可供制备的生鲜禽肉与生鲜禽肉制品、即食或即热禽肉制品、蛋与蛋制品（衍生品）、可供制备的生鲜鱼类与海产品、即食或即热鱼制品与海产品、新鲜蔬果、加工蔬果、干制谷物、水果、坚果、种子与蔬菜、婴儿配方食品、巧克力、烘焙与糖果制品、多组分制品或餐食组分、动物饲料与宠物食品"},{"_id":"6a7d76396040ebab2620d35e","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Pasze i karmy dla zwierząt","methodology":"Obecność Salmonella Typhimurium","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność Salmonella Typhimurium\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020-09 ISO/TR 6579-3:2014","norm_bases":["PN-EN ISO 6579-1:2017-04","PN-EN ISO 6579-1:2017-04/A1:2020-09 ISO/TR 6579-3:2014"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Pasze i karmy dla zwierząt Obecność Salmonella Typhimurium\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020-09 ISO/TR 6579-3:2014 Surowe mieso i surowe produkty miesne gotowe do przygotowania (oprocz drobiu), Produkty miesne gotowe do spozycia lub gotowe do podgrzania, Surowe mieso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z miesa drobiowego gotowe do spozycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spozycia lub gotowe do podgrzania, Swieze warzywa i owoce, Pasze i karmy dla zwierzat Obecnosc Salmonella Typhimurium\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020-09 ISO/TR 6579-3:2014","categories":["food","microbiology"],"row_index":231,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Presence of Salmonella Typhimurium","search_en":"Raw meat and raw meat products ready for preparation (except poultry), Meat products ready to eat or ready to reheat, Raw poultry meat and raw poultry products ready for preparation, Poultry meat products ready to eat or ready to reheat, Eggs and egg products (derivatives), Raw fish and seafood ready for preparation, Fish products and seafood ready to eat or ready to reheat, Fresh vegetables and fruit, Feed and pet food Presence of Salmonella Typhimurium Culture method with biochemical and serological confirmation Microbiology Laboratory Aleksandrów Łódzki PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020-09 ISO/TR 6579-3:2014","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Raw meat and raw meat products ready for preparation (except poultry), Meat products ready to eat or ready to reheat, Raw poultry meat and raw poultry products ready for preparation, Poultry meat products ready to eat or ready to reheat, Eggs and egg products (derivatives), Raw fish and seafood ready for preparation, Fish products and seafood ready to eat or ready to reheat, Fresh vegetables and fruit, Feed and pet food","search_zh":"鼠伤寒沙门氏菌的检出 培养法结合生化与血清学确认 微生物实验室 Aleksandrów Łódzki PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020-09 ISO/TR 6579-3:2014","technique_zh":"培养法结合生化与血清学确认","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","methodology_zh":"鼠伤寒沙门氏菌的检出"},{"_id":"6a7d76396040ebab2620d35f","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Pasze i karmy dla zwierząt","methodology":"Obecność Salmonella Enteritidis","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność Salmonella Enteritidis\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020-09 ISO/TR 6579-3:2014","norm_bases":["PN-EN ISO 6579-1:2017-04","PN-EN ISO 6579-1:2017-04/A1:2020-09 ISO/TR 6579-3:2014"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Surowe mięso i surowe produkty mięsne gotowe do przygotowania (oprócz drobiu), Produkty mięsne gotowe do spożycia lub gotowe do podgrzania, Surowe mięso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z mięsa drobiowego gotowe do spożycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spożycia lub gotowe do podgrzania, Świeże warzywa i owoce, Pasze i karmy dla zwierząt Obecność Salmonella Enteritidis\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020-09 ISO/TR 6579-3:2014 Surowe mieso i surowe produkty miesne gotowe do przygotowania (oprocz drobiu), Produkty miesne gotowe do spozycia lub gotowe do podgrzania, Surowe mieso drobiowe i surowe produkty drobiowe gotowe do przygotowania, Produkty z miesa drobiowego gotowe do spozycia lub gotowe do podgrzania, Jaja i produkty jajeczne (pochodne), Ryby i owoce morza surowe, gotowe do przygotowania, Produkty rybne i owoce morza gotowe do spozycia lub gotowe do podgrzania, Swieze warzywa i owoce, Pasze i karmy dla zwierzat Obecnosc Salmonella Enteritidis\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020-09 ISO/TR 6579-3:2014","categories":["food","microbiology"],"row_index":232,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Presence of Salmonella Enteritidis","search_en":"Raw meat and raw meat products ready for preparation (except poultry), Meat products ready to eat or ready to reheat, Raw poultry meat and raw poultry products ready for preparation, Poultry meat products ready to eat or ready to reheat, Eggs and egg products (derivatives), Raw fish and seafood ready for preparation, Fish products and seafood ready to eat or ready to reheat, Fresh vegetables and fruit, Feed and pet food Presence of Salmonella Enteritidis Culture method with biochemical and serological confirmation Microbiology Laboratory Aleksandrów Łódzki PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020-09 ISO/TR 6579-3:2014","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Raw meat and raw meat products ready for preparation (except poultry), Meat products ready to eat or ready to reheat, Raw poultry meat and raw poultry products ready for preparation, Poultry meat products ready to eat or ready to reheat, Eggs and egg products (derivatives), Raw fish and seafood ready for preparation, Fish products and seafood ready to eat or ready to reheat, Fresh vegetables and fruit, Feed and pet food","search_zh":"肠炎沙门氏菌的检出 培养法结合生化与血清学确认 微生物实验室 Aleksandrów Łódzki PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020-09 ISO/TR 6579-3:2014","technique_zh":"培养法结合生化与血清学确认","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","methodology_zh":"肠炎沙门氏菌的检出"},{"_id":"6a7d76396040ebab2620d360","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością: - wymaz z powierzchni ograniczonej szablonem - wymaz z powierzchni nieograniczonej szablonem","methodology":"Liczba drobnoustrojów w 30°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów w 30°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 4833-1:2013-12 | PN-EN ISO 4833-1:2013-12/A1:2022-06","norm_bases":["PN-EN ISO 4833-1:2013-12","PN-EN ISO 4833-1:2013-12/A1:2022-06"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością: - wymaz z powierzchni ograniczonej szablonem - wymaz z powierzchni nieograniczonej szablonem Liczba drobnoustrojów w 30°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 4833-1:2013-12 | PN-EN ISO 4833-1:2013-12/A1:2022-06 Probki srodowiskowe z obszarow produkcji zywnosci i kosmetykow oraz obrotu zywnoscia: - wymaz z powierzchni ograniczonej szablonem - wymaz z powierzchni nieograniczonej szablonem Liczba drobnoustrojow w 30°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 4833-1:2013-12 | PN-EN ISO 4833-1:2013-12/A1:2022-06","categories":["food","environment","microbiology","pharma"],"row_index":233,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Microorganism count at 30°C","search_en":"Environmental samples from food and cosmetics production areas and food trade areas: - swab from a template-delimited surface - swab from a surface not delimited by a template Microorganism count at 30°C Plate method (pour plate) Microbiology Laboratory Aleksandrów Łódzki PN-EN ISO 4833-1:2013-12 | PN-EN ISO 4833-1:2013-12/A1:2022-06","technique_en":"Plate method (pour plate)","test_object_en":"Environmental samples from food and cosmetics production areas and food trade areas: - swab from a template-delimited surface - swab from a surface not delimited by a template","search_zh":"来自食品与化妆品生产及食品流通场所的环境样品：－ 用模板限定面积的涂抹样 － 未用模板限定面积的涂抹样 30°C 微生物数 平板法（倾注培养） 微生物实验室 Aleksandrów Łódzki PN-EN ISO 4833-1:2013-12 | PN-EN ISO 4833-1:2013-12/A1:2022-06","technique_zh":"平板法（倾注培养）","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","methodology_zh":"30°C 微生物数","test_object_zh":"来自食品与化妆品生产及食品流通场所的环境样品：－ 用模板限定面积的涂抹样 － 未用模板限定面积的涂抹样"},{"_id":"6a7d76396040ebab2620d361","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością: - wymaz z powierzchni ograniczonej szablonem - wymaz z powierzchni nieograniczonej szablonem","methodology":"Liczba Enterobacteriaceae w 37°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba Enterobacteriaceae w 37°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 21528-2:2017-08","norm_bases":["PN-EN ISO 21528-2:2017-08"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością: - wymaz z powierzchni ograniczonej szablonem - wymaz z powierzchni nieograniczonej szablonem Liczba Enterobacteriaceae w 37°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 21528-2:2017-08 Probki srodowiskowe z obszarow produkcji zywnosci i kosmetykow oraz obrotu zywnoscia: - wymaz z powierzchni ograniczonej szablonem - wymaz z powierzchni nieograniczonej szablonem Liczba Enterobacteriaceae w 37°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 21528-2:2017-08","categories":["food","environment","pharma"],"row_index":234,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Enterobacteriaceae count at 37°C","search_en":"Environmental samples from food and cosmetics production areas and food trade areas: - swab from a template-delimited surface - swab from a surface not delimited by a template Enterobacteriaceae count at 37°C Plate method (pour plate) Microbiology Laboratory Aleksandrów Łódzki PN-EN ISO 21528-2:2017-08","technique_en":"Plate method (pour plate)","test_object_en":"Environmental samples from food and cosmetics production areas and food trade areas: - swab from a template-delimited surface - swab from a surface not delimited by a template","search_zh":"来自食品与化妆品生产及食品流通场所的环境样品：－ 用模板限定面积的涂抹样 － 未用模板限定面积的涂抹样 37°C 肠杆菌科计数 平板法（倾注培养） 微生物实验室 Aleksandrów Łódzki PN-EN ISO 21528-2:2017-08","technique_zh":"平板法（倾注培养）","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","methodology_zh":"37°C 肠杆菌科计数","test_object_zh":"来自食品与化妆品生产及食品流通场所的环境样品：－ 用模板限定面积的涂抹样 － 未用模板限定面积的涂抹样"},{"_id":"6a7d76396040ebab2620d362","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością: - wymaz z powierzchni ograniczonej szablonem - wymaz z powierzchni nieograniczonej szablonem","methodology":"Liczba beta-glukuronidazo-dodatnich, Escherichia coli w 44°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba beta-glukuronidazo-dodatnich, Escherichia coli w 44°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 16649-2:2004","norm_bases":["PN-ISO 16649-2:2004"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością: - wymaz z powierzchni ograniczonej szablonem - wymaz z powierzchni nieograniczonej szablonem Liczba beta-glukuronidazo-dodatnich, Escherichia coli w 44°C\nMetoda płytkowa (posiew wgłębny) PN-ISO 16649-2:2004 Probki srodowiskowe z obszarow produkcji zywnosci i kosmetykow oraz obrotu zywnoscia: - wymaz z powierzchni ograniczonej szablonem - wymaz z powierzchni nieograniczonej szablonem Liczba beta-glukuronidazo-dodatnich, Escherichia coli w 44°C\nMetoda plytkowa (posiew wglebny) PN-ISO 16649-2:2004","categories":["food","environment","microbiology","pharma"],"row_index":235,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Count of beta-glucuronidase-positive, Escherichia coli at 44°C","search_en":"Environmental samples from food and cosmetics production areas and food trade areas: - swab from a template-delimited surface - swab from a surface not delimited by a template Count of beta-glucuronidase-positive, Escherichia coli at 44°C Plate method (pour plate) Microbiology Laboratory Aleksandrów Łódzki PN-ISO 16649-2:2004","technique_en":"Plate method (pour plate)","test_object_en":"Environmental samples from food and cosmetics production areas and food trade areas: - swab from a template-delimited surface - swab from a surface not delimited by a template","search_zh":"来自食品与化妆品生产及食品流通场所的环境样品：－ 用模板限定面积的涂抹样 － 未用模板限定面积的涂抹样 平板法（倾注培养） 微生物实验室 Aleksandrów Łódzki PN-ISO 16649-2:2004","technique_zh":"平板法（倾注培养）","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","test_object_zh":"来自食品与化妆品生产及食品流通场所的环境样品：－ 用模板限定面积的涂抹样 － 未用模板限定面积的涂抹样"},{"_id":"6a7d76396040ebab2620d363","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności oraz obrotu żywnością: - wymaz z powierzchni ograniczonej szablonem - wymaz z powierzchni nieograniczonej szablonem - wymaz z tusz zwierząt rzeźnych","methodology":"Obecność Listeria monocytogenes","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 11290-1:2017-07","norm_bases":["PN-EN ISO 11290-1:2017-07"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności oraz obrotu żywnością: - wymaz z powierzchni ograniczonej szablonem - wymaz z powierzchni nieograniczonej szablonem - wymaz z tusz zwierząt rzeźnych Obecność Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290-1:2017-07 Probki srodowiskowe z obszarow produkcji zywnosci oraz obrotu zywnoscia: - wymaz z powierzchni ograniczonej szablonem - wymaz z powierzchni nieograniczonej szablonem - wymaz z tusz zwierzat rzeznych Obecnosc Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290-1:2017-07","categories":["food","environment","microbiology"],"row_index":236,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Presence of Listeria monocytogenes","search_en":"Environmental samples from food production and food trade areas: - swab from a template-delimited surface - swab from a surface not delimited by a template - swab from slaughter animal carcasses Presence of Listeria monocytogenes Culture method with biochemical confirmation Microbiology Laboratory Aleksandrów Łódzki PN-EN ISO 11290-1:2017-07","technique_en":"Culture method with biochemical confirmation","test_object_en":"Environmental samples from food production and food trade areas: - swab from a template-delimited surface - swab from a surface not delimited by a template - swab from slaughter animal carcasses","search_zh":"单核细胞增生李斯特氏菌的检出 培养法结合生化确认 微生物实验室 Aleksandrów Łódzki PN-EN ISO 11290-1:2017-07","technique_zh":"培养法结合生化确认","methodology_zh":"单核细胞增生李斯特氏菌的检出","lab_section_zh":"微生物实验室 Aleksandrów Łódzki"},{"_id":"6a7d76396040ebab2620d364","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności oraz obrotu żywnością: - wymaz z powierzchni ograniczonej szablonem - wymaz z powierzchni nieograniczonej szablonem - wymaz z tusz zwierząt rzeźnych","methodology":"Obecność bakterii z rodzaju, Salmonella spp.","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność bakterii z rodzaju, Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020-09","norm_bases":["PN-EN ISO 6579-1:2017-04","PN-EN ISO 6579-1:2017-04/A1:2020-09"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności oraz obrotu żywnością: - wymaz z powierzchni ograniczonej szablonem - wymaz z powierzchni nieograniczonej szablonem - wymaz z tusz zwierząt rzeźnych Obecność bakterii z rodzaju, Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020-09 Probki srodowiskowe z obszarow produkcji zywnosci oraz obrotu zywnoscia: - wymaz z powierzchni ograniczonej szablonem - wymaz z powierzchni nieograniczonej szablonem - wymaz z tusz zwierzat rzeznych Obecnosc bakterii z rodzaju, Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020-09","categories":["microbiology","food","environment"],"row_index":237,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Presence of bacteria of the genus, Salmonella spp.","search_en":"Environmental samples from food production and food trade areas: - swab from a template-delimited surface - swab from a surface not delimited by a template - swab from slaughter animal carcasses Presence of bacteria of the genus, Salmonella spp. Culture method with biochemical and serological confirmation Microbiology Laboratory Aleksandrów Łódzki PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020-09","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Environmental samples from food production and food trade areas: - swab from a template-delimited surface - swab from a surface not delimited by a template - swab from slaughter animal carcasses","search_zh":"培养法结合生化与血清学确认 微生物实验室 Aleksandrów Łódzki PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020-09","technique_zh":"培养法结合生化与血清学确认","lab_section_zh":"微生物实验室 Aleksandrów Łódzki"},{"_id":"6a7d76396040ebab2620d365","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda, woda na pływalniach","methodology":"Liczba mikroorganizmów w 36°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba mikroorganizmów w 36°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda, woda na pływalniach Liczba mikroorganizmów w 36°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi, woda, woda na plywalniach Liczba mikroorganizmow w 36°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":238,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Count of microorganisms at 36°C","search_en":"Water intended for human consumption, water, swimming pool water Count of microorganisms at 36°C Plate method (pour plate) Microbiology Laboratory Aleksandrów Łódzki PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water intended for human consumption, water, swimming pool water","search_zh":"生活饮用水、水、游泳池水 平板法（倾注培养） 微生物实验室 Aleksandrów Łódzki PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","test_object_zh":"生活饮用水、水、游泳池水"},{"_id":"6a7d76396040ebab2620d366","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda, woda na pływalniach","methodology":"Liczba mikroorganizmów w 22°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba mikroorganizmów w 22°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda, woda na pływalniach Liczba mikroorganizmów w 22°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi, woda, woda na plywalniach Liczba mikroorganizmow w 22°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":239,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Microorganism count at 22°C","search_en":"Water intended for human consumption, water, swimming pool water Microorganism count at 22°C Plate method (pour plate) Microbiology Laboratory Aleksandrów Łódzki PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water intended for human consumption, water, swimming pool water","search_zh":"生活饮用水、水、游泳池水 22°C 微生物数 平板法（倾注培养） 微生物实验室 Aleksandrów Łódzki PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","test_object_zh":"生活饮用水、水、游泳池水","methodology_zh":"22°C 微生物数"},{"_id":"6a7d76396040ebab2620d367","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda, woda na pływalniach","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12/A1:2017-04"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda, woda na pływalniach Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04 Woda do spozycia przez ludzi, woda, woda na plywalniach Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","categories":["water","microbiology"],"row_index":240,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Coliform bacteria count","search_en":"Water intended for human consumption, water, swimming pool water Coliform bacteria count Membrane filtration method Microbiology Laboratory Aleksandrów Łódzki PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption, water, swimming pool water","methodology_zh":"大肠菌群计数","search_zh":"生活饮用水、水、游泳池水 大肠菌群计数 膜过滤法 微生物实验室 Aleksandrów Łódzki PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_zh":"膜过滤法","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","test_object_zh":"生活饮用水、水、游泳池水"},{"_id":"6a7d76396040ebab2620d368","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda, woda na pływalniach","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12/A1:2017-04"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda, woda na pływalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04 Woda do spozycia przez ludzi, woda, woda na plywalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","categories":["water","microbiology"],"row_index":241,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Escherichia coli count","search_en":"Water intended for human consumption, water, swimming pool water Escherichia coli count Membrane filtration method Microbiology Laboratory Aleksandrów Łódzki PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption, water, swimming pool water","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"生活饮用水、水、游泳池水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 微生物实验室 Aleksandrów Łódzki PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_zh":"膜过滤法","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","test_object_zh":"生活饮用水、水、游泳池水"},{"_id":"6a7d76396040ebab2620d369","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda, woda na pływalniach","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda, woda na pływalniach Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi, woda, woda na plywalniach Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":242,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Intestinal enterococci count","search_en":"Water intended for human consumption, water, swimming pool water Intestinal enterococci count Membrane filtration method Microbiology Laboratory Aleksandrów Łódzki PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption, water, swimming pool water","methodology_zh":"粪肠球菌计数","search_zh":"生活饮用水、水、游泳池水 粪肠球菌计数 膜过滤法 微生物实验室 Aleksandrów Łódzki PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","test_object_zh":"生活饮用水、水、游泳池水"},{"_id":"6a7d76396040ebab2620d36a","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda, woda na pływalniach","methodology":"Liczba Clostridium perfringens (łącznie z przetrwalnikami)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Clostridium perfringens (łącznie z przetrwalnikami)\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda, woda na pływalniach Liczba Clostridium perfringens (łącznie z przetrwalnikami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda do spozycia przez ludzi, woda, woda na plywalniach Liczba Clostridium perfringens (lacznie z przetrwalnikami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":243,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Clostridium perfringens count (including spores)","search_en":"Water intended for human consumption, water, swimming pool water Clostridium perfringens count (including spores) Membrane filtration method Microbiology Laboratory Aleksandrów Łódzki PN-EN ISO 14189:2016-10","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption, water, swimming pool water","search_zh":"生活饮用水、水、游泳池水 产气荚膜梭菌数（含芽孢） 膜过滤法 微生物实验室 Aleksandrów Łódzki PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","methodology_zh":"产气荚膜梭菌数（含芽孢）","test_object_zh":"生活饮用水、水、游泳池水"},{"_id":"6a7d76396040ebab2620d36b","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda, woda na pływalniach","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda, woda na pływalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda do spozycia przez ludzi, woda, woda na plywalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":244,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Pseudomonas aeruginosa count","search_en":"Water intended for human consumption, water, swimming pool water Pseudomonas aeruginosa count Membrane filtration method Microbiology Laboratory Aleksandrów Łódzki PN-EN ISO 16266:2009","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption, water, swimming pool water","methodology_zh":"铜绿假单胞菌计数","search_zh":"生活饮用水、水、游泳池水 铜绿假单胞菌计数 膜过滤法 微生物实验室 Aleksandrów Łódzki PN-EN ISO 16266:2009","technique_zh":"膜过滤法","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","test_object_zh":"生活饮用水、水、游泳池水"},{"_id":"6a7d76396040ebab2620d36c","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda, woda na pływalniach","methodology":"Liczba przetrwalników beztlenowców redukujących siarczyny (clostridia)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba przetrwalników beztlenowców redukujących siarczyny (clostridia)\nMetoda filtracji membranowej","reference":"PN-EN 26461-2:2001","norm_bases":["PN-EN 26461-2:2001"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda, woda na pływalniach Liczba przetrwalników beztlenowców redukujących siarczyny (clostridia)\nMetoda filtracji membranowej PN-EN 26461-2:2001 Woda do spozycia przez ludzi, woda, woda na plywalniach Liczba przetrwalnikow beztlenowcow redukujacych siarczyny (clostridia)\nMetoda filtracji membranowej PN-EN 26461-2:2001","categories":["water"],"row_index":245,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Count of spores of sulphite-reducing anaerobes (clostridia)","search_en":"Water intended for human consumption, water, swimming pool water Count of spores of sulphite-reducing anaerobes (clostridia) Membrane filtration method Microbiology Laboratory Aleksandrów Łódzki PN-EN 26461-2:2001","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption, water, swimming pool water","search_zh":"生活饮用水、水、游泳池水 亚硫酸盐还原厌氧菌（梭菌）芽孢计数 膜过滤法 微生物实验室 Aleksandrów Łódzki PN-EN 26461-2:2001","technique_zh":"膜过滤法","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","methodology_zh":"亚硫酸盐还原厌氧菌（梭菌）芽孢计数","test_object_zh":"生活饮用水、水、游泳池水"},{"_id":"6a7d76396040ebab2620d36d","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda, woda na pływalniach","methodology":"Liczba Legionella spp., Matryca A: Procedura 7; Pożywka C (GVPC), Procedura 5; Pożywka A (BCYE)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Legionella spp., Matryca A: Procedura 7; Pożywka C (GVPC), Procedura 5; Pożywka A (BCYE)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08","PN-EN ISO 11731:2017-08/Ap1:2019-12"],"lab_section":"Pracownia Mikrobiologii Aleksandrów Łódzki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda, woda na pływalniach Liczba Legionella spp., Matryca A: Procedura 7; Pożywka C (GVPC), Procedura 5; Pożywka A (BCYE)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12 Woda do spozycia przez ludzi, woda, woda na plywalniach Liczba Legionella spp., Matryca A: Procedura 7; Pozywka C (GVPC), Procedura 5; Pozywka A (BCYE)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12","categories":["microbiology","water"],"row_index":246,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory Aleksandrów Łódzki","methodology_en":"Legionella spp. count, Matrix A: Procedure 7; Medium C (GVPC), Procedure 5; Medium A (BCYE)","search_en":"Water intended for human consumption, water, swimming pool water Legionella spp. count, Matrix A: Procedure 7; Medium C (GVPC), Procedure 5; Medium A (BCYE) Membrane filtration method Microbiology Laboratory Aleksandrów Łódzki PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption, water, swimming pool water","search_zh":"生活饮用水、水、游泳池水 膜过滤法 微生物实验室 Aleksandrów Łódzki PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12","technique_zh":"膜过滤法","lab_section_zh":"微生物实验室 Aleksandrów Łódzki","test_object_zh":"生活饮用水、水、游泳池水"},{"_id":"6a7d76396040ebab2620d36e","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Wyroby elektryczne przeznaczone do kontaktu z żywnością, Materiały i wyroby ceramiczne przeznaczone do kontaktu z żywnością, Materiały i wyroby szklane, Papier, tektura, Materiały i elementy opakowaniowe przeznaczone do kontaktu z żywnością, Wyroby z tworzyw sztucznych i gumy przeznaczone do kontaktu z żywnością, Materiały do produkcji opakowań, Wyroby do przechowywania żywności, Włóknina, wyroby i elementy drewniane przeznaczone do kontaktu z żywnością","methodology":"Zapach i smak przekazywane przy bezpośrednim kontakcie","parameters":[{"name":"Zakres","range":"0 – 4"}],"technique":"Metoda multiporównawcza","techniques":["Metoda multiporównawcza"],"computed":[],"activity":"Zapach i smak przekazywane przy bezpośrednim kontakcie\nZakres 0 – 4\nMetoda multiporównawcza","reference":"DIN 10955:2024-01","norm_bases":["DIN 10955:2024-01"],"lab_section":"Pracownia Analiz Sensorycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby elektryczne przeznaczone do kontaktu z żywnością, Materiały i wyroby ceramiczne przeznaczone do kontaktu z żywnością, Materiały i wyroby szklane, Papier, tektura, Materiały i elementy opakowaniowe przeznaczone do kontaktu z żywnością, Wyroby z tworzyw sztucznych i gumy przeznaczone do kontaktu z żywnością, Materiały do produkcji opakowań, Wyroby do przechowywania żywności, Włóknina, wyroby i elementy drewniane przeznaczone do kontaktu z żywnością Zapach i smak przekazywane przy bezpośrednim kontakcie\nZakres 0 – 4\nMetoda multiporównawcza DIN 10955:2024-01 Wyroby elektryczne przeznaczone do kontaktu z zywnoscia, Materialy i wyroby ceramiczne przeznaczone do kontaktu z zywnoscia, Materialy i wyroby szklane, Papier, tektura, Materialy i elementy opakowaniowe przeznaczone do kontaktu z zywnoscia, Wyroby z tworzyw sztucznych i gumy przeznaczone do kontaktu z zywnoscia, Materialy do produkcji opakowan, Wyroby do przechowywania zywnosci, Wloknina, wyroby i elementy drewniane przeznaczone do kontaktu z zywnoscia Zapach i smak przekazywane przy bezposrednim kontakcie\nZakres 0 – 4\nMetoda multiporownawcza DIN 10955:2024-01","categories":["materials","food"],"row_index":247,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sensory Analysis Laboratory","methodology_en":"Odour and taste transferred on direct contact","parameters_en":[{"name":"Range","range":"0 – 4"}],"search_en":"Electrical articles intended to come into contact with food, Ceramic materials and articles intended to come into contact with food, Glass materials and articles, Paper, board, Packaging materials and components intended to come into contact with food, Plastic and rubber articles intended to come into contact with food, Materials for packaging production, Articles for food storage, Nonwoven fabric, wooden articles and components intended to come into contact with food Odour and taste transferred on direct contact Multi-comparative method Sensory Analysis Laboratory Range DIN 10955:2024-01","technique_en":"Multi-comparative method","test_object_en":"Electrical articles intended to come into contact with food, Ceramic materials and articles intended to come into contact with food, Glass materials and articles, Paper, board, Packaging materials and components intended to come into contact with food, Plastic and rubber articles intended to come into contact with food, Materials for packaging production, Articles for food storage, Nonwoven fabric, wooden articles and components intended to come into contact with food","parameters_zh":[{"name":"范围","range":"0 – 4"}],"search_zh":"直接接触传递的气味与滋味 多重比较法 感官分析检验室 范围 DIN 10955:2024-01","methodology_zh":"直接接触传递的气味与滋味","technique_zh":"多重比较法","lab_section_zh":"感官分析检验室"},{"_id":"6a7d76396040ebab2620d36f","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Papier, tektura","methodology":"Zapach i smak przekazywane przy bezpośrednim kontakcie","parameters":[{"name":"Zakres","range":"0 – 4"}],"technique":"Metoda multiporównawcza","techniques":["Metoda multiporównawcza"],"computed":[],"activity":"Zapach i smak przekazywane przy bezpośrednim kontakcie\nZakres 0 – 4\nMetoda multiporównawcza","reference":"PN-EN 1230-1:2009 | PN-EN 1230-2:2009","norm_bases":["PN-EN 1230-1:2009","PN-EN 1230-2:2009"],"lab_section":"Pracownia Analiz Sensorycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Papier, tektura Zapach i smak przekazywane przy bezpośrednim kontakcie\nZakres 0 – 4\nMetoda multiporównawcza PN-EN 1230-1:2009 | PN-EN 1230-2:2009 Papier, tektura Zapach i smak przekazywane przy bezposrednim kontakcie\nZakres 0 – 4\nMetoda multiporownawcza PN-EN 1230-1:2009 | PN-EN 1230-2:2009","categories":["other"],"row_index":248,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sensory Analysis Laboratory","methodology_en":"Odour and taste transferred on direct contact","parameters_en":[{"name":"Range","range":"0 – 4"}],"search_en":"Paper, board Odour and taste transferred on direct contact Multi-comparative method Sensory Analysis Laboratory Range PN-EN 1230-1:2009 | PN-EN 1230-2:2009","technique_en":"Multi-comparative method","test_object_en":"Paper, board","parameters_zh":[{"name":"范围","range":"0 – 4"}],"search_zh":"纸、纸板 直接接触传递的气味与滋味 多重比较法 感官分析检验室 范围 PN-EN 1230-1:2009 | PN-EN 1230-2:2009","test_object_zh":"纸、纸板","methodology_zh":"直接接触传递的气味与滋味","technique_zh":"多重比较法","lab_section_zh":"感官分析检验室"},{"_id":"6a7d76396040ebab2620d370","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda surowa, woda źródlana, woda mineralna, lód","methodology":"Smak","parameters":[],"technique":"Metoda jakościowa","techniques":["Metoda jakościowa"],"computed":[],"activity":"Smak\nMetoda jakościowa","reference":"PB-201 wyd. 2 z dn. 17.10.2025","norm_bases":["PB-201 wyd. 2 z dn. 17.10.2025"],"lab_section":"Pracownia Analiz Sensorycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda surowa, woda źródlana, woda mineralna, lód Smak\nMetoda jakościowa PB-201 wyd. 2 z dn. 17.10.2025 Woda do spozycia przez ludzi, woda surowa, woda zrodlana, woda mineralna, lod Smak\nMetoda jakosciowa PB-201 wyd. 2 z dn. 17.10.2025","categories":["water"],"row_index":249,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sensory Analysis Laboratory","methodology_en":"Taste","search_en":"Water intended for human consumption, raw water, spring water, mineral water, ice Taste Qualitative method Sensory Analysis Laboratory PB-201 wyd. 2 z dn. 17.10.2025","technique_en":"Qualitative method","test_object_en":"Water intended for human consumption, raw water, spring water, mineral water, ice","search_zh":"定性法 感官分析检验室 PB-201 wyd. 2 z dn. 17.10.2025","technique_zh":"定性法","lab_section_zh":"感官分析检验室"},{"_id":"6a7d76396040ebab2620d371","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda surowa, woda źródlana, woda mineralna, woda przemysłowa, woda technologiczna","methodology":"Zapach","parameters":[],"technique":"Metoda jakościowa","techniques":["Metoda jakościowa"],"computed":[],"activity":"Zapach\nMetoda jakościowa","reference":"PB-201 wyd. 2 z dn. 17.10.2025","norm_bases":["PB-201 wyd. 2 z dn. 17.10.2025"],"lab_section":"Pracownia Analiz Sensorycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda surowa, woda źródlana, woda mineralna, woda przemysłowa, woda technologiczna Zapach\nMetoda jakościowa PB-201 wyd. 2 z dn. 17.10.2025 Woda do spozycia przez ludzi, woda surowa, woda zrodlana, woda mineralna, woda przemyslowa, woda technologiczna Zapach\nMetoda jakosciowa PB-201 wyd. 2 z dn. 17.10.2025","categories":["water"],"row_index":250,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sensory Analysis Laboratory","methodology_en":"Odour","search_en":"Water intended for human consumption, raw water, spring water, mineral water, industrial water, process water Odour Qualitative method Sensory Analysis Laboratory PB-201 wyd. 2 z dn. 17.10.2025","technique_en":"Qualitative method","test_object_en":"Water intended for human consumption, raw water, spring water, mineral water, industrial water, process water","search_zh":"气味 定性法 感官分析检验室 PB-201 wyd. 2 z dn. 17.10.2025","technique_zh":"定性法","lab_section_zh":"感官分析检验室","methodology_zh":"气味"},{"_id":"6a7d76396040ebab2620d372","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Produkty rolne E, Kosmetyki i wyroby chemiczne E","methodology":"Cechy sensoryczne","parameters":[],"technique":"Metoda prosty test opisowy","techniques":["Metoda prosty test opisowy"],"computed":[],"activity":"Cechy sensoryczne\nMetoda prosty test opisowy","reference":"Normy Procedury badawcze Metody opisane przez renomowaną organizację","norm_bases":["Normy Procedury badawcze Metody opisane przez renomowaną organizację"],"lab_section":"Pracownia Analiz Sensorycznych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Produkty rolne E, Kosmetyki i wyroby chemiczne E Cechy sensoryczne\nMetoda prosty test opisowy Normy Procedury badawcze Metody opisane przez renomowaną organizację Zywnosc E, Produkty rolne E, Kosmetyki i wyroby chemiczne E Cechy sensoryczne\nMetoda prosty test opisowy Normy Procedury badawcze Metody opisane przez renomowana organizacje","categories":["food","pharma"],"row_index":251,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sensory Analysis Laboratory","methodology_en":"Sensory characteristics","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Agricultural products E, Cosmetics and chemical products E Sensory characteristics Method simple descriptive test Sensory Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze Metody opisane przez renomowaną organizację","technique_en":"Method simple descriptive test","test_object_en":"Food E, Agricultural products E, Cosmetics and chemical products E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"感官特性 感官分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze Metody opisane przez renomowaną organizację","lab_section_zh":"感官分析检验室","methodology_zh":"感官特性"},{"_id":"6a7d76396040ebab2620d373","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E","methodology":"Cechy sensoryczne","parameters":[],"technique":"Metoda punktowa","techniques":["Metoda punktowa"],"computed":[],"activity":"Cechy sensoryczne\nMetoda punktowa","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Analiz Sensorycznych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Cechy sensoryczne\nMetoda punktowa Normy Procedury badawcze Zywnosc E Cechy sensoryczne\nMetoda punktowa Normy Procedury badawcze","categories":["food"],"row_index":252,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sensory Analysis Laboratory","methodology_en":"Sensory characteristics","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E Sensory characteristics Point method Sensory Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Point method","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E 感官特性 点测法 感官分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","test_object_zh":"食品 E","technique_zh":"点测法","lab_section_zh":"感官分析检验室","methodology_zh":"感官特性"},{"_id":"6a7d76396040ebab2620d374","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Suplementy diety, Premiksy","methodology":"Zawartości witamin rozpuszczalnych w wodzie:","parameters":[{"name":"Witamina B5 (kwas pantotenowy): (0,5 – 5000) mg/100g"},{"name":"Witamina B7 (biotyna): (50 – 50000) ug/100g"},{"name":"Witamina B9 (kwas foliowy): (100 – 200000) ug/100g"},{"name":"Witamina B12 (cyjanokobalamina): (100 – 5000) ug/100g"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)"],"computed":[],"activity":"Zawartości witamin rozpuszczalnych w wodzie:\nZakres:\nWitamina B5 (kwas pantotenowy): (0,5 – 5000) mg/100g\nWitamina B7 (biotyna): (50 – 50000) ug/100g\nWitamina B9 (kwas foliowy): (100 – 200000) ug/100g\nWitamina B12 (cyjanokobalamina): (100 – 5000) ug/100g\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","reference":"PB-597 wyd. 1 z dn. 14.01.2026","norm_bases":["PB-597 wyd. 1 z dn. 14.01.2026"],"lab_section":"Pracownia Analiz Witamin i Dioksyn","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Suplementy diety, Premiksy Zawartości witamin rozpuszczalnych w wodzie:\nZakres:\nWitamina B5 (kwas pantotenowy): (0,5 – 5000) mg/100g\nWitamina B7 (biotyna): (50 – 50000) ug/100g\nWitamina B9 (kwas foliowy): (100 – 200000) ug/100g\nWitamina B12 (cyjanokobalamina): (100 – 5000) ug/100g\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS) PB-597 wyd. 1 z dn. 14.01.2026 Suplementy diety, Premiksy Zawartosci witamin rozpuszczalnych w wodzie:\nZakres:\nWitamina B5 (kwas pantotenowy): (0,5 – 5000) mg/100g\nWitamina B7 (biotyna): (50 – 50000) ug/100g\nWitamina B9 (kwas foliowy): (100 – 200000) ug/100g\nWitamina B12 (cyjanokobalamina): (100 – 5000) ug/100g\nMetoda wysokosprawnej chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS-MS) PB-597 wyd. 1 z dn. 14.01.2026","categories":["pharma"],"row_index":253,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Vitamins and Dioxins Analysis Laboratory","methodology_en":"Contents of water-soluble vitamins:","parameters_en":[{"name":"Vitamin B5 (pantothenic acid): (0,5 – 5000) mg/100g"},{"name":"Vitamin B7 (biotin): (50 – 50000) ug/100g"},{"name":"Vitamin B9 (folic acid): (100 – 200000) ug/100g"},{"name":"Vitamin B12 (cyanocobalamin): (100 – 5000) ug/100g"}],"search_en":"Food supplements, Premixes Contents of water-soluble vitamins: High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS-MS) Vitamins and Dioxins Analysis Laboratory Vitamin B5 (pantothenic acid): (0,5 – 5000) mg/100g Vitamin B7 (biotin): (50 – 50000) ug/100g Vitamin B9 (folic acid): (100 – 200000) ug/100g Vitamin B12 (cyanocobalamin): (100 – 5000) ug/100g PB-597 wyd. 1 z dn. 14.01.2026","technique_en":"High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS-MS)","test_object_en":"Food supplements, Premixes","search_zh":"高效液相色谱-串联质谱法（LC-MS-MS） 维生素与二噁英分析检验室 PB-597 wyd. 1 z dn. 14.01.2026","technique_zh":"高效液相色谱-串联质谱法（LC-MS-MS）","lab_section_zh":"维生素与二噁英分析检验室"},{"_id":"6a7d76396040ebab2620d375","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E","methodology":"Zawartość witamin","parameters":[],"technique":"Metoda mikrobiologiczna z mikroorganizmem jako organizmem testowym","techniques":["Metoda mikrobiologiczna z mikroorganizmem jako organizmem testowym"],"computed":[],"activity":"Zawartość witamin\nMetoda mikrobiologiczna z mikroorganizmem jako organizmem testowym","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Witamin i Dioksyn","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E Zawartość witamin\nMetoda mikrobiologiczna z mikroorganizmem jako organizmem testowym Procedury badawcze Zywnosc E, Pasze dla zwierzat E Zawartosc witamin\nMetoda mikrobiologiczna z mikroorganizmem jako organizmem testowym Procedury badawcze","categories":["food","microbiology"],"row_index":254,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Vitamins and Dioxins Analysis Laboratory","methodology_en":"Vitamin content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E Vitamin content Microbiological method with a microorganism as the test organism Vitamins and Dioxins Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Procedury badawcze","technique_en":"Microbiological method with a microorganism as the test organism","test_object_en":"Food E, Animal feed E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E 维生素含量 维生素与二噁英分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Procedury badawcze","test_object_zh":"食品 E、动物饲料 E","lab_section_zh":"维生素与二噁英分析检验室","methodology_zh":"维生素含量"},{"_id":"6a7d76396040ebab2620d376","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Produkty rolne E, Żywność E, Pasze dla zwierząt E","methodology":"Zawartość witamin","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/Vis), detekcją matrycą diodową (HPLC-DAD) i detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/Vis), detekcją matrycą diodową (HPLC-DAD) i detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość witamin\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/Vis), detekcją matrycą diodową (HPLC-DAD) i detekcją fluorescencyjną (HPLC-FLD)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Analiz Witamin i Dioksyn","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Produkty rolne E, Żywność E, Pasze dla zwierząt E Zawartość witamin\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/Vis), detekcją matrycą diodową (HPLC-DAD) i detekcją fluorescencyjną (HPLC-FLD) Normy Procedury badawcze Produkty rolne E, Zywnosc E, Pasze dla zwierzat E Zawartosc witamin\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV/Vis), detekcja matryca diodowa (HPLC-DAD) i detekcja fluorescencyjna (HPLC-FLD) Normy Procedury badawcze","categories":["food"],"row_index":255,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Vitamins and Dioxins Analysis Laboratory","methodology_en":"Vitamin content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Agricultural products E, Food E, Animal feed E Vitamin content High-performance liquid chromatography with spectrophotometric detection (HPLC-UV/Vis), diode array detection (HPLC-DAD) and fluorescence detection (HPLC-FLD) Vitamins and Dioxins Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV/Vis), diode array detection (HPLC-DAD) and fluorescence detection (HPLC-FLD)","test_object_en":"Agricultural products E, Food E, Animal feed E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"农产品 E、食品 E、动物饲料 E 维生素含量 维生素与二噁英分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","test_object_zh":"农产品 E、食品 E、动物饲料 E","lab_section_zh":"维生素与二噁英分析检验室","methodology_zh":"维生素含量"},{"_id":"6a7d76396040ebab2620d377","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Produkty rolne E, Żywność E, Pasze dla zwierząt E","methodology":"Zawartość dioksyn i dioksynopodobnych PCB oraz wskaźnikowych PCB","parameters":[],"technique":"Metoda chromatografii gazowej z wysokorozdzielczą spektrometrią mas (GC-HRMS)","techniques":["Metoda chromatografii gazowej z wysokorozdzielczą spektrometrią mas (GC-HRMS)"],"computed":[],"activity":"Zawartość dioksyn i dioksynopodobnych PCB oraz wskaźnikowych PCB\nMetoda chromatografii gazowej z wysokorozdzielczą spektrometrią mas (GC-HRMS)","reference":"PB-408","norm_bases":["PB-408"],"lab_section":"Pracownia Analiz Witamin i Dioksyn","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Produkty rolne E, Żywność E, Pasze dla zwierząt E Zawartość dioksyn i dioksynopodobnych PCB oraz wskaźnikowych PCB\nMetoda chromatografii gazowej z wysokorozdzielczą spektrometrią mas (GC-HRMS) PB-408 Produkty rolne E, Zywnosc E, Pasze dla zwierzat E Zawartosc dioksyn i dioksynopodobnych PCB oraz wskaznikowych PCB\nMetoda chromatografii gazowej z wysokorozdzielcza spektrometria mas (GC-HRMS) PB-408","categories":["food"],"row_index":256,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Vitamins and Dioxins Analysis Laboratory","methodology_en":"Content of dioxins and dioxin-like PCBs and indicator PCBs","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Agricultural products E, Food E, Animal feed E Content of dioxins and dioxin-like PCBs and indicator PCBs Gas chromatography with high-resolution mass spectrometry (GC-HRMS) Vitamins and Dioxins Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. PB-408","technique_en":"Gas chromatography with high-resolution mass spectrometry (GC-HRMS)","test_object_en":"Agricultural products E, Food E, Animal feed E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"农产品 E、食品 E、动物饲料 E 维生素与二噁英分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 PB-408","test_object_zh":"农产品 E、食品 E、动物饲料 E","lab_section_zh":"维生素与二噁英分析检验室"},{"_id":"6a7d76396040ebab2620d378","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Produkty rolne E, Żywność E, Pasze dla zwierząt E","methodology":"Zawartość dioksynopodobnych PCB oraz wskaźnikowych PCB","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas(GC-MS-MS)","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas(GC-MS-MS)"],"computed":[],"activity":"Zawartość dioksynopodobnych PCB oraz wskaźnikowych PCB\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas(GC-MS-MS)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Witamin i Dioksyn","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Produkty rolne E, Żywność E, Pasze dla zwierząt E Zawartość dioksynopodobnych PCB oraz wskaźnikowych PCB\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas(GC-MS-MS) Procedury badawcze Produkty rolne E, Zywnosc E, Pasze dla zwierzat E Zawartosc dioksynopodobnych PCB oraz wskaznikowych PCB\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas(GC-MS-MS) Procedury badawcze","categories":["food"],"row_index":257,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Vitamins and Dioxins Analysis Laboratory","methodology_en":"Content of dioxin-like PCBs and indicator PCBs","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Agricultural products E, Food E, Animal feed E Content of dioxin-like PCBs and indicator PCBs Gas chromatography with tandem mass spectrometry detection (GC-MS-MS) Vitamins and Dioxins Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Procedury badawcze","technique_en":"Gas chromatography with tandem mass spectrometry detection (GC-MS-MS)","test_object_en":"Agricultural products E, Food E, Animal feed E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"农产品 E、食品 E、动物饲料 E 维生素与二噁英分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Procedury badawcze","test_object_zh":"农产品 E、食品 E、动物饲料 E","lab_section_zh":"维生素与二噁英分析检验室"},{"_id":"6a7d76396040ebab2620d379","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Produkty rolne E, Żywność E, Pasze dla zwierząt E","methodology":"Zawartość aminokwasów","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/Vis) i z detekcją matrycą diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/Vis) i z detekcją matrycą diodową (HPLC-DAD)"],"computed":[],"activity":"Zawartość aminokwasów\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/Vis) i z detekcją matrycą diodową (HPLC-DAD)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Witamin i Dioksyn","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Produkty rolne E, Żywność E, Pasze dla zwierząt E Zawartość aminokwasów\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/Vis) i z detekcją matrycą diodową (HPLC-DAD) Procedury badawcze Produkty rolne E, Zywnosc E, Pasze dla zwierzat E Zawartosc aminokwasow\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV/Vis) i z detekcja matryca diodowa (HPLC-DAD) Procedury badawcze","categories":["food"],"row_index":258,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Vitamins and Dioxins Analysis Laboratory","methodology_en":"Amino acid content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Agricultural products E, Food E, Animal feed E Amino acid content High-performance liquid chromatography with spectrophotometric detection (HPLC-UV/Vis) and with diode array detection (HPLC-DAD) Vitamins and Dioxins Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Procedury badawcze","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV/Vis) and with diode array detection (HPLC-DAD)","test_object_en":"Agricultural products E, Food E, Animal feed E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"农产品 E、食品 E、动物饲料 E 氨基酸含量 高效液相色谱-分光光度检测法（HPLC-UV/Vis）与二极管阵列检测法（HPLC-DAD） 维生素与二噁英分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Procedury badawcze","test_object_zh":"农产品 E、食品 E、动物饲料 E","lab_section_zh":"维生素与二噁英分析检验室","methodology_zh":"氨基酸含量","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV/Vis）与二极管阵列检测法（HPLC-DAD）"},{"_id":"6a7d76396040ebab2620d37a","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie wielopierścieniowych","parameters":[{"name":"węglowodorów aromatycznych (WWA)"},{"name":"benzo(b)fluoranten"},{"name":"Zakres","range":"(0,0020 – 0,020) μg/l"},{"name":"benzo(k)fluoranten","range":"(0,0020 – 0,020) μg/l"},{"name":"benzo(a)piren","range":"(0,0025 – 0,020) μg/l"},{"name":"benzo(ghi)perylen","range":"(0,0040 – 0,020) μg/l"},{"name":"indeno","range":"(1,2,3cd)piren"},{"name":"(0,0040 – 0,020) μg/l"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie wielopierścieniowych\nZakres:\nwęglowodorów aromatycznych (WWA)\nbenzo(b)fluoranten\nZakres (0,0020 – 0,020) μg/l\nbenzo(k)fluoranten (0,0020 – 0,020) μg/l\nbenzo(a)piren (0,0025 – 0,020) μg/l\nbenzo(ghi)perylen (0,0040 – 0,020) μg/l\nindeno (1,2,3cd)piren\n(0,0040 – 0,020) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PN-EN ISO 17993:2005","norm_bases":["PN-EN ISO 17993:2005"],"lab_section":"Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie wielopierścieniowych\nZakres:\nwęglowodorów aromatycznych (WWA)\nbenzo(b)fluoranten\nZakres (0,0020 – 0,020) μg/l\nbenzo(k)fluoranten (0,0020 – 0,020) μg/l\nbenzo(a)piren (0,0025 – 0,020) μg/l\nbenzo(ghi)perylen (0,0040 – 0,020) μg/l\nindeno (1,2,3cd)piren\n(0,0040 – 0,020) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PN-EN ISO 17993:2005 Woda, woda do spozycia przez ludzi Stezenie wielopierscieniowych\nZakres:\nweglowodorow aromatycznych (WWA)\nbenzo(b)fluoranten\nZakres (0,0020 – 0,020) μg/l\nbenzo(k)fluoranten (0,0020 – 0,020) μg/l\nbenzo(a)piren (0,0025 – 0,020) μg/l\nbenzo(ghi)perylen (0,0040 – 0,020) μg/l\nindeno (1,2,3cd)piren\n(0,0040 – 0,020) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PN-EN ISO 17993:2005","categories":["water"],"row_index":259,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Instrumental Analysis Laboratory","methodology_en":"Concentration of polycyclic","parameters_en":[{"name":"aromatic hydrocarbons (PAH)"},{"name":"benzo(b)fluoranthene"},{"name":"Range","range":"(0,0020 – 0,020) μg/l"},{"name":"benzo(k)fluoranthene","range":"(0,0020 – 0,020) μg/l"},{"name":"benzo(a)pyrene","range":"(0,0025 – 0,020) μg/l"},{"name":"benzo(ghi)perylene","range":"(0,0040 – 0,020) μg/l"},{"name":"indeno","range":"(1,2,3cd)piren"},{"name":"(0,0040 – 0,020) μg/l"}],"search_en":"Water, water intended for human consumption Concentration of polycyclic High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Instrumental Analysis Laboratory aromatic hydrocarbons (PAH) benzo(b)fluoranthene Range benzo(k)fluoranthene benzo(a)pyrene benzo(ghi)perylene indeno (0,0040 – 0,020) μg/l PN-EN ISO 17993:2005","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"多环芳烃（PAH）"},{"name":"苯并（b）荧蒽"},{"name":"范围","range":"(0,0020 – 0,020) μg/l"},{"name":"苯并（k）荧蒽","range":"(0,0020 – 0,020) μg/l"},{"name":"苯并（a）芘","range":"(0,0025 – 0,020) μg/l"},{"name":"苯并（ghi）苝","range":"(0,0040 – 0,020) μg/l"},{"name":"茚","range":"(1,2,3cd)piren"},{"name":"(0,0040 – 0,020) μg/l"}],"search_zh":"水、生活饮用水 多环烃浓度 高效液相色谱-荧光检测法（HPLC-FLD） 仪器分析检验室 多环芳烃（PAH） 苯并（b）荧蒽 范围 苯并（k）荧蒽 苯并（a）芘 苯并（ghi）苝 茚 PN-EN ISO 17993:2005","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"水、生活饮用水","lab_section_zh":"仪器分析检验室","methodology_zh":"多环烃浓度"},{"_id":"6a7d76396040ebab2620d37b","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Oleje i tłuszcze roślinne oraz zwierzęce","methodology":"Zawartość wolnego i związanego 2-MCPD, wolnego i związanego 3-MCPD oraz estrów glicydylowych","parameters":[{"name":"Zakres","range":"2-monochloropropano-1,3-diol (2-"},{"name":"MCPD)","range":"(0,15 – 2,5) mg/kg"},{"name":"3-monochloropropano-1,2-diol","range":"(3-MCPD)"},{"name":"(0,15 – 2,5) mg/kg"},{"name":"3-monochloropropano-1,2-diol (3-MCPD) z uwzględnieniem glicydolu","range":"(0,15 – 2,5) mg/kg"},{"name":"Zawartość glicydolu (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość wolnego i związanego 2-MCPD, wolnego i związanego 3-MCPD oraz estrów glicydylowych\nZakres:\nZakres 2-monochloropropano-1,3-diol (2-\nMCPD) (0,15 – 2,5) mg/kg\n3-monochloropropano-1,2-diol (3-MCPD)\n(0,15 – 2,5) mg/kg\n3-monochloropropano-1,2-diol (3-MCPD) z uwzględnieniem glicydolu (0,15 – 2,5) mg/kg\nZawartość glicydolu (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"D G F C-VI 18 (10) Part A, Part B","norm_bases":["D G F C-VI 18 (10) Part A, Part B"],"lab_section":"Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oleje i tłuszcze roślinne oraz zwierzęce Zawartość wolnego i związanego 2-MCPD, wolnego i związanego 3-MCPD oraz estrów glicydylowych\nZakres:\nZakres 2-monochloropropano-1,3-diol (2-\nMCPD) (0,15 – 2,5) mg/kg\n3-monochloropropano-1,2-diol (3-MCPD)\n(0,15 – 2,5) mg/kg\n3-monochloropropano-1,2-diol (3-MCPD) z uwzględnieniem glicydolu (0,15 – 2,5) mg/kg\nZawartość glicydolu (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) D G F C-VI 18 (10) Part A, Part B Oleje i tluszcze roslinne oraz zwierzece Zawartosc wolnego i zwiazanego 2-MCPD, wolnego i zwiazanego 3-MCPD oraz estrow glicydylowych\nZakres:\nZakres 2-monochloropropano-1,3-diol (2-\nMCPD) (0,15 – 2,5) mg/kg\n3-monochloropropano-1,2-diol (3-MCPD)\n(0,15 – 2,5) mg/kg\n3-monochloropropano-1,2-diol (3-MCPD) z uwzglednieniem glicydolu (0,15 – 2,5) mg/kg\nZawartosc glicydolu (z obliczen)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) D G F C-VI 18 (10) Part A, Part B","categories":["food","petro"],"row_index":260,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Instrumental Analysis Laboratory","methodology_en":"Content of free and bound 2-MCPD, free and bound 3-MCPD and glycidyl esters","parameters_en":[{"name":"Range","range":"2-monochloropropano-1,3-diol (2-"},{"name":"MCPD)","range":"(0,15 – 2,5) mg/kg"},{"name":"3-monochloropropane-1,2-diol","range":"(3-MCPD)"},{"name":"(0,15 – 2,5) mg/kg"},{"name":"3-monochloropropane-1,2-diol (3-MCPD) including glycidol","range":"(0,15 – 2,5) mg/kg"},{"name":"Glycidol content (calculated)"}],"search_en":"Vegetable and animal oils and fats Content of free and bound 2-MCPD, free and bound 3-MCPD and glycidyl esters Gas chromatography with mass spectrometry detection (GC-MS) Instrumental Analysis Laboratory Range MCPD) 3-monochloropropane-1,2-diol (0,15 – 2,5) mg/kg 3-monochloropropane-1,2-diol (3-MCPD) including glycidol Glycidol content (calculated) D G F C-VI 18 (10) Part A, Part B","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Vegetable and animal oils and fats","parameters_zh":[{"name":"范围","range":"2-monochloropropano-1,3-diol (2-"},{"name":"MCPD)","range":"(0,15 – 2,5) mg/kg"},{"name":"3-monochloropropano-1,2-diol","range":"(3-MCPD)"},{"name":"(0,15 – 2,5) mg/kg"},{"name":"3-monochloropropano-1,2-diol (3-MCPD) z uwzględnieniem glicydolu","range":"(0,15 – 2,5) mg/kg"},{"name":"Zawartość glicydolu (z obliczeń)"}],"search_zh":"植物油脂与动物油脂 气相色谱-质谱法（GC-MS） 仪器分析检验室 范围 D G F C-VI 18 (10) Part A, Part B","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"植物油脂与动物油脂","lab_section_zh":"仪器分析检验室"},{"_id":"6a7d76396040ebab2620d37c","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Wyroby ciastkarskie i cukiernicze, Przekąski zbożowe i ziemniaczane","methodology":"Zawartość wolnego i związanego 2-MCPD, wolnego i związanego 3-MCPD oraz estrów glicydylowych w wyekstrahowanym tłuszczu","parameters":[{"name":"Zakres","range":"2-monochloropropano-1,3-diol (2-"},{"name":"MCPD)","range":"(0,15 – 2,5) mg/kg tłuszczu"},{"name":"3-monochloropropano-1,2-diol","range":"(3-MCPD)"},{"name":"(0,15 – 2,5) mg/kg tłuszczu"},{"name":"3-monochloropropano-1,2-diol (3-MCPD) z uwzględnieniem glicydolu","range":"(0,15 – 2,5) mg/kg tłuszczu"},{"name":"W przeliczeniu na produkt (z obliczeń) Zawartość glicydolu (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość wolnego i związanego 2-MCPD, wolnego i związanego 3-MCPD oraz estrów glicydylowych w wyekstrahowanym tłuszczu\nZakres:\nZakres 2-monochloropropano-1,3-diol (2-\nMCPD) (0,15 – 2,5) mg/kg tłuszczu\n3-monochloropropano-1,2-diol (3-MCPD)\n(0,15 – 2,5) mg/kg tłuszczu\n3-monochloropropano-1,2-diol (3-MCPD) z uwzględnieniem glicydolu (0,15 – 2,5) mg/kg tłuszczu\nW przeliczeniu na produkt (z obliczeń) Zawartość glicydolu (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"D G F C-VI 18 (10) Part A, Part B","norm_bases":["D G F C-VI 18 (10) Part A, Part B"],"lab_section":"Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby ciastkarskie i cukiernicze, Przekąski zbożowe i ziemniaczane Zawartość wolnego i związanego 2-MCPD, wolnego i związanego 3-MCPD oraz estrów glicydylowych w wyekstrahowanym tłuszczu\nZakres:\nZakres 2-monochloropropano-1,3-diol (2-\nMCPD) (0,15 – 2,5) mg/kg tłuszczu\n3-monochloropropano-1,2-diol (3-MCPD)\n(0,15 – 2,5) mg/kg tłuszczu\n3-monochloropropano-1,2-diol (3-MCPD) z uwzględnieniem glicydolu (0,15 – 2,5) mg/kg tłuszczu\nW przeliczeniu na produkt (z obliczeń) Zawartość glicydolu (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) D G F C-VI 18 (10) Part A, Part B Wyroby ciastkarskie i cukiernicze, Przekaski zbozowe i ziemniaczane Zawartosc wolnego i zwiazanego 2-MCPD, wolnego i zwiazanego 3-MCPD oraz estrow glicydylowych w wyekstrahowanym tluszczu\nZakres:\nZakres 2-monochloropropano-1,3-diol (2-\nMCPD) (0,15 – 2,5) mg/kg tluszczu\n3-monochloropropano-1,2-diol (3-MCPD)\n(0,15 – 2,5) mg/kg tluszczu\n3-monochloropropano-1,2-diol (3-MCPD) z uwzglednieniem glicydolu (0,15 – 2,5) mg/kg tluszczu\nW przeliczeniu na produkt (z obliczen) Zawartosc glicydolu (z obliczen)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) D G F C-VI 18 (10) Part A, Part B","categories":["food"],"row_index":261,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Instrumental Analysis Laboratory","methodology_en":"Content of free and bound 2-MCPD, free and bound 3-MCPD and glycidyl esters in the extracted fat","parameters_en":[{"name":"Range","range":"2-monochloropropano-1,3-diol (2-"},{"name":"MCPD)","range":"(0,15 – 2,5) mg/kg tłuszczu"},{"name":"3-monochloropropane-1,2-diol","range":"(3-MCPD)"},{"name":"(0,15 – 2,5) mg/kg fat"},{"name":"3-monochloropropane-1,2-diol (3-MCPD) including glycidol","range":"(0,15 – 2,5) mg/kg tłuszczu"},{"name":"Calculated per product (calculated) Glycidol content (calculated)"}],"search_en":"Pastry and confectionery products, Cereal and potato snacks Content of free and bound 2-MCPD, free and bound 3-MCPD and glycidyl esters in the extracted fat Gas chromatography with mass spectrometry detection (GC-MS) Instrumental Analysis Laboratory Range MCPD) 3-monochloropropane-1,2-diol (0,15 – 2,5) mg/kg fat 3-monochloropropane-1,2-diol (3-MCPD) including glycidol Calculated per product (calculated) Glycidol content (calculated) D G F C-VI 18 (10) Part A, Part B","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Pastry and confectionery products, Cereal and potato snacks","parameters_zh":[{"name":"范围","range":"2-monochloropropano-1,3-diol (2-"},{"name":"MCPD)","range":"(0,15 – 2,5) mg/kg tłuszczu"},{"name":"3-monochloropropano-1,2-diol","range":"(3-MCPD)"},{"name":"(0,15 – 2,5) mg/kg tłuszczu"},{"name":"3-monochloropropano-1,2-diol (3-MCPD) z uwzględnieniem glicydolu","range":"(0,15 – 2,5) mg/kg tłuszczu"},{"name":"W przeliczeniu na produkt (z obliczeń) Zawartość glicydolu (z obliczeń)"}],"search_zh":"气相色谱-质谱法（GC-MS） 仪器分析检验室 范围 D G F C-VI 18 (10) Part A, Part B","technique_zh":"气相色谱-质谱法（GC-MS）","lab_section_zh":"仪器分析检验室"},{"_id":"6a7d76396040ebab2620d37d","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość substancji dodatkowych","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/Vis), detekcją matrycą diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/Vis), detekcją matrycą diodową (HPLC-DAD)"],"computed":[],"activity":"Zawartość substancji dodatkowych\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/Vis), detekcją matrycą diodową (HPLC-DAD)","reference":"PN-EN 12856","norm_bases":["PN-EN 12856"],"lab_section":"Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość substancji dodatkowych\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/Vis), detekcją matrycą diodową (HPLC-DAD) PN-EN 12856 Zywnosc E Zawartosc substancji dodatkowych\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV/Vis), detekcja matryca diodowa (HPLC-DAD) PN-EN 12856","categories":["food"],"row_index":262,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Instrumental Analysis Laboratory","methodology_en":"Content of additives","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E Content of additives High-performance liquid chromatography with spectrophotometric detection (HPLC-UV/Vis), diode array detection (HPLC-DAD) Instrumental Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. PN-EN 12856","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV/Vis), diode array detection (HPLC-DAD)","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E 仪器分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 PN-EN 12856","test_object_zh":"食品 E","lab_section_zh":"仪器分析检验室"},{"_id":"6a7d76396040ebab2620d37e","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PB-117/HPLC","norm_bases":["PB-117/HPLC"],"lab_section":"Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PB-117/HPLC Zywnosc E Zawartosc wielopierscieniowych weglowodorow aromatycznych (WWA)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PB-117/HPLC","categories":["food"],"row_index":263,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Instrumental Analysis Laboratory","methodology_en":"Polycyclic aromatic hydrocarbons (PAH) content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E Polycyclic aromatic hydrocarbons (PAH) content High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Instrumental Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. PB-117/HPLC","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E 多环芳烃（PAHs）含量 高效液相色谱-荧光检测法（HPLC-FLD） 仪器分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 PB-117/HPLC","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"食品 E","methodology_zh":"多环芳烃（PAHs）含量","lab_section_zh":"仪器分析检验室"},{"_id":"6a7d76396040ebab2620d37f","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość azotanów i/lub azotynów","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/Vis) i z detekcją matrycą diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/Vis) i z detekcją matrycą diodową (HPLC-DAD)"],"computed":[],"activity":"Zawartość azotanów i/lub azotynów\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/Vis) i z detekcją matrycą diodową (HPLC-DAD)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość azotanów i/lub azotynów\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/Vis) i z detekcją matrycą diodową (HPLC-DAD) Normy Zywnosc E Zawartosc azotanow i/lub azotynow\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV/Vis) i z detekcja matryca diodowa (HPLC-DAD) Normy","categories":["food"],"row_index":264,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Instrumental Analysis Laboratory","methodology_en":"Nitrate and/or nitrite content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E Nitrate and/or nitrite content High-performance liquid chromatography with spectrophotometric detection (HPLC-UV/Vis) and with diode array detection (HPLC-DAD) Instrumental Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV/Vis) and with diode array detection (HPLC-DAD)","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E 高效液相色谱-分光光度检测法（HPLC-UV/Vis）与二极管阵列检测法（HPLC-DAD） 仪器分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy","test_object_zh":"食品 E","lab_section_zh":"仪器分析检验室","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV/Vis）与二极管阵列检测法（HPLC-DAD）"},{"_id":"6a7d76396040ebab2620d380","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość akryloamidu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość akryloamidu\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość akryloamidu\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) Procedury badawcze Zywnosc E Zawartosc akryloamidu\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) Procedury badawcze","categories":["food"],"row_index":265,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Instrumental Analysis Laboratory","methodology_en":"Acrylamide content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E Acrylamide content Gas chromatography with mass spectrometry detection (GC-MS) Instrumental Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Procedury badawcze","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E 丙烯酰胺含量 气相色谱-质谱法（GC-MS） 仪器分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Procedury badawcze","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"食品 E","lab_section_zh":"仪器分析检验室","methodology_zh":"丙烯酰胺含量"},{"_id":"6a7d76396040ebab2620d381","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)"],"computed":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","reference":"PB-506","norm_bases":["PB-506"],"lab_section":"Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS) PB-506 Zywnosc E Zawartosc wielopierscieniowych weglowodorow aromatycznych (WWA)\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC-MS-MS) PB-506","categories":["food"],"row_index":266,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Instrumental Analysis Laboratory","methodology_en":"Polycyclic aromatic hydrocarbons (PAH) content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E Polycyclic aromatic hydrocarbons (PAH) content Gas chromatography with tandem mass spectrometry detection (GC-MS-MS) Instrumental Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. PB-506","technique_en":"Gas chromatography with tandem mass spectrometry detection (GC-MS-MS)","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E 多环芳烃（PAHs）含量 气相色谱-串联质谱法（GC-MS-MS） 仪器分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 PB-506","test_object_zh":"食品 E","methodology_zh":"多环芳烃（PAHs）含量","technique_zh":"气相色谱-串联质谱法（GC-MS-MS）","lab_section_zh":"仪器分析检验室"},{"_id":"6a7d76396040ebab2620d382","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość alkaloidów tropanowych","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)"],"computed":[],"activity":"Zawartość alkaloidów tropanowych\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość alkaloidów tropanowych\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS) Procedury badawcze Zywnosc E Zawartosc alkaloidow tropanowych\nMetoda wysokosprawnej chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS-MS) Procedury badawcze","categories":["food"],"row_index":267,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Instrumental Analysis Laboratory","methodology_en":"Tropane alkaloid content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E Tropane alkaloid content High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS-MS) Instrumental Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Procedury badawcze","technique_en":"High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS-MS)","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E 高效液相色谱-串联质谱法（LC-MS-MS） 仪器分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Procedury badawcze","test_object_zh":"食品 E","lab_section_zh":"仪器分析检验室","technique_zh":"高效液相色谱-串联质谱法（LC-MS-MS）"},{"_id":"6a7d76396040ebab2620d383","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość alkaloidów pirolizydynowych","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)"],"computed":[],"activity":"Zawartość alkaloidów pirolizydynowych\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość alkaloidów pirolizydynowych\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS) Procedury badawcze Zywnosc E Zawartosc alkaloidow pirolizydynowych\nMetoda wysokosprawnej chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS-MS) Procedury badawcze","categories":["food"],"row_index":268,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Instrumental Analysis Laboratory","methodology_en":"Pyrrolizidine alkaloid content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E Pyrrolizidine alkaloid content High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS-MS) Instrumental Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Procedury badawcze","technique_en":"High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS-MS)","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E 高效液相色谱-串联质谱法（LC-MS-MS） 仪器分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Procedury badawcze","test_object_zh":"食品 E","lab_section_zh":"仪器分析检验室","technique_zh":"高效液相色谱-串联质谱法（LC-MS-MS）"},{"_id":"6a7d76396040ebab2620d384","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Produkty rolne E, Żywność E, Pasze dla zwierząt E","methodology":"Zawartość mykotoksyn","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) oraz z detekcją spektrofotometryczną (HPLC-UV/Vis) i z detekcją matrycą diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) oraz z detekcją spektrofotometryczną (HPLC-UV/Vis) i z detekcją matrycą diodową (HPLC-DAD)"],"computed":[],"activity":"Zawartość mykotoksyn\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) oraz z detekcją spektrofotometryczną (HPLC-UV/Vis) i z detekcją matrycą diodową (HPLC-DAD)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Produkty rolne E, Żywność E, Pasze dla zwierząt E Zawartość mykotoksyn\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) oraz z detekcją spektrofotometryczną (HPLC-UV/Vis) i z detekcją matrycą diodową (HPLC-DAD) Normy Procedury badawcze Produkty rolne E, Zywnosc E, Pasze dla zwierzat E Zawartosc mykotoksyn\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) oraz z detekcja spektrofotometryczna (HPLC-UV/Vis) i z detekcja matryca diodowa (HPLC-DAD) Normy Procedury badawcze","categories":["food"],"row_index":269,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Instrumental Analysis Laboratory","methodology_en":"Mycotoxin content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Agricultural products E, Food E, Animal feed E Mycotoxin content High-performance liquid chromatography with fluorescence detection (HPLC-FLD) and with spectrophotometric detection (HPLC-UV/Vis) and with diode array detection (HPLC-DAD) Instrumental Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD) and with spectrophotometric detection (HPLC-UV/Vis) and with diode array detection (HPLC-DAD)","test_object_en":"Agricultural products E, Food E, Animal feed E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"农产品 E、食品 E、动物饲料 E 霉菌毒素含量 仪器分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","methodology_zh":"霉菌毒素含量","lab_section_zh":"仪器分析检验室","test_object_zh":"农产品 E、食品 E、动物饲料 E"},{"_id":"6a7d76396040ebab2620d385","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Produkty rolne E, Żywność E, Pasze dla zwierząt E","methodology":"Zawartość mykotoksyn","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)"],"computed":[],"activity":"Zawartość mykotoksyn\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Produkty rolne E, Żywność E, Pasze dla zwierząt E Zawartość mykotoksyn\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS) Procedury badawcze Produkty rolne E, Zywnosc E, Pasze dla zwierzat E Zawartosc mykotoksyn\nMetoda wysokosprawnej chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS-MS) Procedury badawcze","categories":["food"],"row_index":270,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Instrumental Analysis Laboratory","methodology_en":"Mycotoxin content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Agricultural products E, Food E, Animal feed E Mycotoxin content High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS-MS) Instrumental Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Procedury badawcze","technique_en":"High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS-MS)","test_object_en":"Agricultural products E, Food E, Animal feed E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"农产品 E、食品 E、动物饲料 E 霉菌毒素含量 高效液相色谱-串联质谱法（LC-MS-MS） 仪器分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Procedury badawcze","methodology_zh":"霉菌毒素含量","lab_section_zh":"仪器分析检验室","technique_zh":"高效液相色谱-串联质谱法（LC-MS-MS）","test_object_zh":"农产品 E、食品 E、动物饲料 E"},{"_id":"6a7d76396040ebab2620d386","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Produkty rolne E, Żywność E, Pasze dla zwierząt E","methodology":"Zawartość melaminy i jej analogów","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)"],"computed":[],"activity":"Zawartość melaminy i jej analogów\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Produkty rolne E, Żywność E, Pasze dla zwierząt E Zawartość melaminy i jej analogów\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS) Procedury badawcze Produkty rolne E, Zywnosc E, Pasze dla zwierzat E Zawartosc melaminy i jej analogow\nMetoda wysokosprawnej chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS-MS) Procedury badawcze","categories":["food"],"row_index":271,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Instrumental Analysis Laboratory","methodology_en":"Melamine and its analogues content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Agricultural products E, Food E, Animal feed E Melamine and its analogues content High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS-MS) Instrumental Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Procedury badawcze","technique_en":"High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS-MS)","test_object_en":"Agricultural products E, Food E, Animal feed E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"农产品 E、食品 E、动物饲料 E 高效液相色谱-串联质谱法（LC-MS-MS） 仪器分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Procedury badawcze","lab_section_zh":"仪器分析检验室","technique_zh":"高效液相色谱-串联质谱法（LC-MS-MS）","test_object_zh":"农产品 E、食品 E、动物饲料 E"},{"_id":"6a7d76396040ebab2620d387","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Pasze dla zwierząt E, Żywność E","methodology":"Zawartość amin biogennych","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/Vis) i z detekcją matrycą diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/Vis) i z detekcją matrycą diodową (HPLC-DAD)"],"computed":[],"activity":"Zawartość amin biogennych\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/Vis) i z detekcją matrycą diodową (HPLC-DAD)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Pasze dla zwierząt E, Żywność E Zawartość amin biogennych\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/Vis) i z detekcją matrycą diodową (HPLC-DAD) Normy Procedury badawcze Pasze dla zwierzat E, Zywnosc E Zawartosc amin biogennych\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV/Vis) i z detekcja matryca diodowa (HPLC-DAD) Normy Procedury badawcze","categories":["food"],"row_index":272,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Instrumental Analysis Laboratory","methodology_en":"Biogenic amine content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Animal feed E, Food E Biogenic amine content High-performance liquid chromatography with spectrophotometric detection (HPLC-UV/Vis) and with diode array detection (HPLC-DAD) Instrumental Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV/Vis) and with diode array detection (HPLC-DAD)","test_object_en":"Animal feed E, Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"生物胺含量 高效液相色谱-分光光度检测法（HPLC-UV/Vis）与二极管阵列检测法（HPLC-DAD） 仪器分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","lab_section_zh":"仪器分析检验室","methodology_zh":"生物胺含量","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV/Vis）与二极管阵列检测法（HPLC-DAD）"},{"_id":"6a7d76396040ebab2620d388","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki, gleby, osady ściekowe E, Środki wspomagające uprawę roślin E","methodology":"Stężenie/zawartość pierwiastków","parameters":[],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie/zawartość pierwiastków\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Spektrometrii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki, gleby, osady ściekowe E, Środki wspomagające uprawę roślin E Stężenie/zawartość pierwiastków\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Normy Procedury badawcze Woda, woda do spozycia przez ludzi, scieki, gleby, osady sciekowe E, Srodki wspomagajace uprawe roslin E Stezenie/zawartosc pierwiastkow\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Normy Procedury badawcze","categories":["water"],"row_index":273,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Spectrometry Laboratory","methodology_en":"Element concentration/content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Water, water intended for human consumption, wastewater, soils, sewage sludge E, Plant cultivation aids E Element concentration/content Inductively coupled plasma optical emission spectrometry (ICP-OES) Spectrometry Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water, water intended for human consumption, wastewater, soils, sewage sludge E, Plant cultivation aids E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"元素的浓度/含量 电感耦合等离子体原子发射光谱法（ICP-OES） 光谱检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","lab_section_zh":"光谱检验室","methodology_zh":"元素的浓度/含量"},{"_id":"6a7d76396040ebab2620d389","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Woda, woda do spożycia przez ludzi, ścieki, gleby, osady ściekowe E, Środki wspomagające uprawę roślin E","methodology":"Stężenie/zawartość rtęci","parameters":[],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Stężenie/zawartość rtęci\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Spektrometrii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Woda, woda do spożycia przez ludzi, ścieki, gleby, osady ściekowe E, Środki wspomagające uprawę roślin E Stężenie/zawartość rtęci\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) Normy Procedury badawcze Zywnosc E, Woda, woda do spozycia przez ludzi, scieki, gleby, osady sciekowe E, Srodki wspomagajace uprawe roslin E Stezenie/zawartosc rteci\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) Normy Procedury badawcze","categories":["water","food"],"row_index":274,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Spectrometry Laboratory","methodology_en":"Concentration/content of mercury","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Water, water intended for human consumption, wastewater, soils, sewage sludge E, Plant cultivation aids E Concentration/content of mercury Cold vapour atomic absorption spectrometry (CVAAS) Spectrometry Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"Food E, Water, water intended for human consumption, wastewater, soils, sewage sludge E, Plant cultivation aids E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"汞的浓度/含量 冷蒸气原子吸收光谱法（CVAAS） 光谱检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","lab_section_zh":"光谱检验室","methodology_zh":"汞的浓度/含量"},{"_id":"6a7d76396040ebab2620d38a","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Produkty rolne E, Pasze dla zwierząt E, Woda, woda do spożycia przez ludzi, ścieki, gleby, osady ściekowe E","methodology":"Stężenie/zawartość pierwiastków","parameters":[],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Stężenie/zawartość pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Spektrometrii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Produkty rolne E, Pasze dla zwierząt E, Woda, woda do spożycia przez ludzi, ścieki, gleby, osady ściekowe E Stężenie/zawartość pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) Normy Procedury badawcze Zywnosc E, Produkty rolne E, Pasze dla zwierzat E, Woda, woda do spozycia przez ludzi, scieki, gleby, osady sciekowe E Stezenie/zawartosc pierwiastkow\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) Normy Procedury badawcze","categories":["water","food"],"row_index":275,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Spectrometry Laboratory","methodology_en":"Element concentration/content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Agricultural products E, Animal feed E, Water, water intended for human consumption, wastewater, soils, sewage sludge E Element concentration/content Inductively coupled plasma mass spectrometry (ICP-MS) Spectrometry Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Food E, Agricultural products E, Animal feed E, Water, water intended for human consumption, wastewater, soils, sewage sludge E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"元素的浓度/含量 电感耦合等离子体质谱法（ICP-MS） 光谱检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","lab_section_zh":"光谱检验室","methodology_zh":"元素的浓度/含量"},{"_id":"6a7d76396040ebab2620d38b","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Produkty rolne E","methodology":"Stężenie/zawartość pierwiastków","parameters":[],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość pierwiastków\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Spektrometrii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Produkty rolne E Stężenie/zawartość pierwiastków\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) Procedury badawcze Zywnosc E, Produkty rolne E Stezenie/zawartosc pierwiastkow\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) Procedury badawcze","categories":["food"],"row_index":276,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Spectrometry Laboratory","methodology_en":"Element concentration/content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Agricultural products E Element concentration/content Flame atomic absorption spectrometry (FAAS) Spectrometry Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Procedury badawcze","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Food E, Agricultural products E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、农产品 E 元素的浓度/含量 火焰原子吸收光谱法（FAAS） 光谱检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Procedury badawcze","technique_zh":"火焰原子吸收光谱法（FAAS）","lab_section_zh":"光谱检验室","test_object_zh":"食品 E、农产品 E","methodology_zh":"元素的浓度/含量"},{"_id":"6a7d76396040ebab2620d38c","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Produkty rolne E, Pasze dla zwierząt E","methodology":"Stężenie/zawartość pierwiastków","parameters":[],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnej sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnej sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie/zawartość pierwiastków\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnej sprzężonej (ICP-OES)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Spektrometrii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Produkty rolne E, Pasze dla zwierząt E Stężenie/zawartość pierwiastków\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnej sprzężonej (ICP-OES) Procedury badawcze Zywnosc E, Produkty rolne E, Pasze dla zwierzat E Stezenie/zawartosc pierwiastkow\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnej sprzezonej (ICP-OES) Procedury badawcze","categories":["food"],"row_index":277,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Spectrometry Laboratory","methodology_en":"Element concentration/content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Agricultural products E, Animal feed E Element concentration/content Inductively coupled plasma optical emission spectrometry (ICP-OES) Spectrometry Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Procedury badawcze","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Food E, Agricultural products E, Animal feed E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、农产品 E、动物饲料 E 元素的浓度/含量 电感耦合等离子体原子发射光谱法（ICP-OES） 光谱检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Procedury badawcze","lab_section_zh":"光谱检验室","test_object_zh":"食品 E、农产品 E、动物饲料 E","methodology_zh":"元素的浓度/含量","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）"},{"_id":"6a7d76396040ebab2620d38d","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Produkty rolne E, Pasze dla zwierząt E","methodology":"Zawartość NaCl (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość NaCl (z obliczeń)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Spektrometrii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Produkty rolne E, Pasze dla zwierząt E Zawartość NaCl (z obliczeń) Procedury badawcze Zywnosc E, Produkty rolne E, Pasze dla zwierzat E Zawartosc NaCl (z obliczen) Procedury badawcze","categories":["food"],"row_index":278,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Spectrometry Laboratory","methodology_en":"NaCl content (calculated)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Agricultural products E, Animal feed E NaCl content (calculated) Spectrometry Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Procedury badawcze","test_object_en":"Food E, Agricultural products E, Animal feed E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、农产品 E、动物饲料 E 光谱检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Procedury badawcze","lab_section_zh":"光谱检验室","test_object_zh":"食品 E、农产品 E、动物饲料 E"},{"_id":"6a7d76396040ebab2620d38e","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Produkty rolne E, Pasze dla zwierząt E","methodology":"Zawartość P2O5 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość P2O5 (z obliczeń)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Spektrometrii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Produkty rolne E, Pasze dla zwierząt E Zawartość P2O5 (z obliczeń) Procedury badawcze Zywnosc E, Produkty rolne E, Pasze dla zwierzat E Zawartosc P2O5 (z obliczen) Procedury badawcze","categories":["food"],"row_index":279,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Spectrometry Laboratory","methodology_en":"P2O5 content (calculated)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Agricultural products E, Animal feed E P2O5 content (calculated) Spectrometry Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Procedury badawcze","test_object_en":"Food E, Agricultural products E, Animal feed E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、农产品 E、动物饲料 E P2O5 含量（由计算得出） 光谱检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Procedury badawcze","lab_section_zh":"光谱检验室","test_object_zh":"食品 E、农产品 E、动物饲料 E","methodology_zh":"P2O5 含量（由计算得出）"},{"_id":"6a7d76396040ebab2620d38f","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Produkty rolne E, Pasze dla zwierząt E","methodology":"Stężenie/zawartość arsenu nieorganicznego (suma As (III) i As(V))","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej ze spektrometrią mas z jonizacją w plazmie indukcyjnie sprzężonej (HPLC-ICP-MS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej ze spektrometrią mas z jonizacją w plazmie indukcyjnie sprzężonej (HPLC-ICP-MS)"],"computed":[],"activity":"Stężenie/zawartość arsenu nieorganicznego (suma As (III) i As(V))\nMetoda wysokosprawnej chromatografii cieczowej ze spektrometrią mas z jonizacją w plazmie indukcyjnie sprzężonej (HPLC-ICP-MS)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Spektrometrii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Produkty rolne E, Pasze dla zwierząt E Stężenie/zawartość arsenu nieorganicznego (suma As (III) i As(V))\nMetoda wysokosprawnej chromatografii cieczowej ze spektrometrią mas z jonizacją w plazmie indukcyjnie sprzężonej (HPLC-ICP-MS) Normy Zywnosc E, Produkty rolne E, Pasze dla zwierzat E Stezenie/zawartosc arsenu nieorganicznego (suma As (III) i As(V))\nMetoda wysokosprawnej chromatografii cieczowej ze spektrometria mas z jonizacja w plazmie indukcyjnie sprzezonej (HPLC-ICP-MS) Normy","categories":["food"],"row_index":280,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Spectrometry Laboratory","methodology_en":"Concentration/content of inorganic arsenic (sum of As (III) and As(V))","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Agricultural products E, Animal feed E Concentration/content of inorganic arsenic (sum of As (III) and As(V)) High-performance liquid chromatography with inductively coupled plasma mass spectrometry (HPLC-ICP-MS) Spectrometry Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy","technique_en":"High-performance liquid chromatography with inductively coupled plasma mass spectrometry (HPLC-ICP-MS)","test_object_en":"Food E, Agricultural products E, Animal feed E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、农产品 E、动物饲料 E 光谱检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy","lab_section_zh":"光谱检验室","test_object_zh":"食品 E、农产品 E、动物饲料 E"},{"_id":"6a7d76396040ebab2620d390","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Koncentraty spożywcze, Mięso i produkty mięsne, Ryby i przetwory rybne oraz owoce morza, Wyroby garmażeryjne, Drób i produkty drobiarskie, Mleko i produkty mleczne, Zboża i przetwory zbożowe, Owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, Środki specjalnego przeznaczenia żywieniowego, Słodycze i wyroby cukiernicze, Surowce i przetwory zielarskie, przyprawy, Oleje, tłuszcze zwierzęce i roślinne, Suplementy diety i odżywki, Pasze dla zwierząt","methodology":"Aktywność wody","parameters":[{"name":"Zakres","range":"(0,100 – 1,000)"}],"technique":"Metoda pomiaru prężności par","techniques":["Metoda pomiaru prężności par"],"computed":[],"activity":"Aktywność wody\nZakres (0,100 – 1,000)\nMetoda pomiaru prężności par","reference":"PN-ISO 21807:2005","norm_bases":["PN-ISO 21807:2005"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Koncentraty spożywcze, Mięso i produkty mięsne, Ryby i przetwory rybne oraz owoce morza, Wyroby garmażeryjne, Drób i produkty drobiarskie, Mleko i produkty mleczne, Zboża i przetwory zbożowe, Owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, Środki specjalnego przeznaczenia żywieniowego, Słodycze i wyroby cukiernicze, Surowce i przetwory zielarskie, przyprawy, Oleje, tłuszcze zwierzęce i roślinne, Suplementy diety i odżywki, Pasze dla zwierząt Aktywność wody\nZakres (0,100 – 1,000)\nMetoda pomiaru prężności par PN-ISO 21807:2005 Koncentraty spozywcze, Mieso i produkty miesne, Ryby i przetwory rybne oraz owoce morza, Wyroby garmazeryjne, Drob i produkty drobiarskie, Mleko i produkty mleczne, Zboza i przetwory zbozowe, Owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-miesne, Srodki specjalnego przeznaczenia zywieniowego, Slodycze i wyroby cukiernicze, Surowce i przetwory zielarskie, przyprawy, Oleje, tluszcze zwierzece i roslinne, Suplementy diety i odzywki, Pasze dla zwierzat Aktywnosc wody\nZakres (0,100 – 1,000)\nMetoda pomiaru preznosci par PN-ISO 21807:2005","categories":["food","water","petro","pharma"],"row_index":281,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Water activity","parameters_en":[{"name":"Range","range":"(0,100 – 1,000)"}],"search_en":"Food concentrates, Meat and meat products, Fish and fish products and seafood, Delicatessen products, Poultry and poultry products, Milk and dairy products, Cereals and cereal products, Fruit and vegetables and fruit and vegetable products and vegetable-meat products, Foodstuffs for particular nutritional uses, Sweets and confectionery, Herbal raw materials and products, spices, Oils, animal and vegetable fats, Dietary supplements and nutritional preparations, Animal feed Water activity Method for measuring vapour pressure Classical Analyses Laboratory Range PN-ISO 21807:2005","technique_en":"Method for measuring vapour pressure","test_object_en":"Food concentrates, Meat and meat products, Fish and fish products and seafood, Delicatessen products, Poultry and poultry products, Milk and dairy products, Cereals and cereal products, Fruit and vegetables and fruit and vegetable products and vegetable-meat products, Foodstuffs for particular nutritional uses, Sweets and confectionery, Herbal raw materials and products, spices, Oils, animal and vegetable fats, Dietary supplements and nutritional preparations, Animal feed","methodology_zh":"水分活度","parameters_zh":[{"name":"范围","range":"(0,100 – 1,000)"}],"search_zh":"水分活度 经典分析实验室 范围 PN-ISO 21807:2005","lab_section_zh":"经典分析实验室"},{"_id":"6a7d76396040ebab2620d391","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Kazeiniany","methodology":"Wskaźnik nierozpuszczalności (rozpuszczalności)","parameters":[{"name":"Zakres","range":"(0,1 – 3,0) ml"}],"technique":"Metoda wirówkowa","techniques":["Metoda wirówkowa"],"computed":[],"activity":"Wskaźnik nierozpuszczalności (rozpuszczalności)\nZakres (0,1 – 3,0) ml\nMetoda wirówkowa","reference":"ISO 8156:2005 IDF-FIL 129:2005","norm_bases":["ISO 8156:2005 IDF-FIL 129:2005"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kazeiniany Wskaźnik nierozpuszczalności (rozpuszczalności)\nZakres (0,1 – 3,0) ml\nMetoda wirówkowa ISO 8156:2005 IDF-FIL 129:2005 Kazeiniany Wskaznik nierozpuszczalnosci (rozpuszczalnosci)\nZakres (0,1 – 3,0) ml\nMetoda wirowkowa ISO 8156:2005 IDF-FIL 129:2005","categories":["other"],"row_index":282,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Insolubility (solubility) index","parameters_en":[{"name":"Range","range":"(0,1 – 3,0) ml"}],"search_en":"Caseinates Insolubility (solubility) index Centrifugal method Classical Analyses Laboratory Range ISO 8156:2005 IDF-FIL 129:2005","technique_en":"Centrifugal method","test_object_en":"Caseinates","parameters_zh":[{"name":"范围","range":"(0,1 – 3,0) ml"}],"search_zh":"不溶性（溶解度）指数 离心法 经典分析实验室 范围 ISO 8156:2005 IDF-FIL 129:2005","lab_section_zh":"经典分析实验室","methodology_zh":"不溶性（溶解度）指数","technique_zh":"离心法"},{"_id":"6a7d76396040ebab2620d392","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Kazeina i kazeiniany","methodology":"Cząstki przypalone","parameters":[{"name":"Zakres","range":"A – D"}],"technique":"Metoda filtracyjna","techniques":["Metoda filtracyjna"],"computed":[],"activity":"Cząstki przypalone\nZakres A – D\nMetoda filtracyjna","reference":"ISO 5739:2003 IDF-FIL 107:2003 | PN-ISO 5739:2010","norm_bases":["ISO 5739:2003 IDF-FIL 107:2003","PN-ISO 5739:2010"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kazeina i kazeiniany Cząstki przypalone\nZakres A – D\nMetoda filtracyjna ISO 5739:2003 IDF-FIL 107:2003 | PN-ISO 5739:2010 Kazeina i kazeiniany Czastki przypalone\nZakres A – D\nMetoda filtracyjna ISO 5739:2003 IDF-FIL 107:2003 | PN-ISO 5739:2010","categories":["other"],"row_index":283,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Scorched particles","parameters_en":[{"name":"Range","range":"A – D"}],"search_en":"Casein and caseinates Scorched particles Filtration method Classical Analyses Laboratory Range ISO 5739:2003 IDF-FIL 107:2003 | PN-ISO 5739:2010","technique_en":"Filtration method","test_object_en":"Casein and caseinates","parameters_zh":[{"name":"范围","range":"A – D"}],"search_zh":"过滤法 经典分析实验室 范围 ISO 5739:2003 IDF-FIL 107:2003 | PN-ISO 5739:2010","lab_section_zh":"经典分析实验室","technique_zh":"过滤法"},{"_id":"6a7d76396040ebab2620d393","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Napoje alkoholowe: piwo","methodology":"Zawartość alkoholu","parameters":[{"name":"Zakres","range":"(0,2 – 10,0) % (v/v)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość alkoholu\nZakres (0,2 – 10,0) % (v/v)\nMetoda wagowa","reference":"PN-A-79093-2:2000+Ap1:2002","norm_bases":["PN-A-79093-2:2000+Ap1:2002"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje alkoholowe: piwo Zawartość alkoholu\nZakres (0,2 – 10,0) % (v/v)\nMetoda wagowa PN-A-79093-2:2000+Ap1:2002 Napoje alkoholowe: piwo Zawartosc alkoholu\nZakres (0,2 – 10,0) % (v/v)\nMetoda wagowa PN-A-79093-2:2000+Ap1:2002","categories":["food"],"row_index":284,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Alcohol content","parameters_en":[{"name":"Range","range":"(0,2 – 10,0) % (v/v)"}],"search_en":"Alcoholic beverages: beer Alcohol content Gravimetric method Classical Analyses Laboratory Range PN-A-79093-2:2000+Ap1:2002","technique_en":"Gravimetric method","test_object_en":"Alcoholic beverages: beer","parameters_zh":[{"name":"范围","range":"(0,2 – 10,0) % (v/v)"}],"search_zh":"酒精含量 重量法 经典分析实验室 范围 PN-A-79093-2:2000+Ap1:2002","technique_zh":"重量法","lab_section_zh":"经典分析实验室","methodology_zh":"酒精含量"},{"_id":"6a7d76396040ebab2620d394","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Ryby i przetwory rybne oraz owoce morza","methodology":"Zawartość lotnych zasad amonowych","parameters":[{"name":"Zakres","range":"(4,0 – 150,0) mg N/100 g"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość lotnych zasad amonowych\nZakres (4,0 – 150,0) mg N/100 g\nMetoda miareczkowa","reference":"PN-A-86791:1995","norm_bases":["PN-A-86791:1995"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ryby i przetwory rybne oraz owoce morza Zawartość lotnych zasad amonowych\nZakres (4,0 – 150,0) mg N/100 g\nMetoda miareczkowa PN-A-86791:1995 Ryby i przetwory rybne oraz owoce morza Zawartosc lotnych zasad amonowych\nZakres (4,0 – 150,0) mg N/100 g\nMetoda miareczkowa PN-A-86791:1995","categories":["other"],"row_index":285,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Volatile ammonium base content","parameters_en":[{"name":"Range","range":"(4,0 – 150,0) mg N/100 g"}],"search_en":"Fish and fish products and seafood Volatile ammonium base content Titrimetric method Classical Analyses Laboratory Range PN-A-86791:1995","technique_en":"Titrimetric method","test_object_en":"Fish and fish products and seafood","parameters_zh":[{"name":"范围","range":"(4,0 – 150,0) mg N/100 g"}],"search_zh":"鱼、鱼制品与海产品 挥发性盐基氮含量 滴定法 经典分析实验室 范围 PN-A-86791:1995","technique_zh":"滴定法","lab_section_zh":"经典分析实验室","methodology_zh":"挥发性盐基氮含量","test_object_zh":"鱼、鱼制品与海产品"},{"_id":"6a7d76396040ebab2620d395","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Produkty mleczne: maślanka w proszku","methodology":"Wskaźnik nierozpuszczalności (rozpuszczalności)","parameters":[{"name":"Zakres","range":"(0,1 – 3,0) ml"}],"technique":"Metoda wirówkowa","techniques":["Metoda wirówkowa"],"computed":[],"activity":"Wskaźnik nierozpuszczalności (rozpuszczalności)\nZakres (0,1 – 3,0) ml\nMetoda wirówkowa","reference":"ISO 8156:2005 IDF-FIL 129:2005","norm_bases":["ISO 8156:2005 IDF-FIL 129:2005"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Produkty mleczne: maślanka w proszku Wskaźnik nierozpuszczalności (rozpuszczalności)\nZakres (0,1 – 3,0) ml\nMetoda wirówkowa ISO 8156:2005 IDF-FIL 129:2005 Produkty mleczne: maslanka w proszku Wskaznik nierozpuszczalnosci (rozpuszczalnosci)\nZakres (0,1 – 3,0) ml\nMetoda wirowkowa ISO 8156:2005 IDF-FIL 129:2005","categories":["other"],"row_index":286,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Insolubility (solubility) index","parameters_en":[{"name":"Range","range":"(0,1 – 3,0) ml"}],"search_en":"Dairy products: buttermilk powder Insolubility (solubility) index Centrifugal method Classical Analyses Laboratory Range ISO 8156:2005 IDF-FIL 129:2005","technique_en":"Centrifugal method","test_object_en":"Dairy products: buttermilk powder","parameters_zh":[{"name":"范围","range":"(0,1 – 3,0) ml"}],"search_zh":"不溶性（溶解度）指数 离心法 经典分析实验室 范围 ISO 8156:2005 IDF-FIL 129:2005","lab_section_zh":"经典分析实验室","methodology_zh":"不溶性（溶解度）指数","technique_zh":"离心法"},{"_id":"6a7d76396040ebab2620d396","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Mleko w proszku","methodology":"Wskaźnik nierozpuszczalności (rozpuszczalności)","parameters":[{"name":"Zakres","range":"(0,1 – 3,0) ml"}],"technique":"Metoda wirówkowa","techniques":["Metoda wirówkowa"],"computed":[],"activity":"Wskaźnik nierozpuszczalności (rozpuszczalności)\nZakres (0,1 – 3,0) ml\nMetoda wirówkowa","reference":"ISO 8156:2005 IDF-FIL 129:2005 ADPI, Section 1, 2016","norm_bases":["ISO 8156:2005 IDF-FIL 129:2005 ADPI, Section 1, 2016"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko w proszku Wskaźnik nierozpuszczalności (rozpuszczalności)\nZakres (0,1 – 3,0) ml\nMetoda wirówkowa ISO 8156:2005 IDF-FIL 129:2005 ADPI, Section 1, 2016 Mleko w proszku Wskaznik nierozpuszczalnosci (rozpuszczalnosci)\nZakres (0,1 – 3,0) ml\nMetoda wirowkowa ISO 8156:2005 IDF-FIL 129:2005 ADPI, Section 1, 2016","categories":["food"],"row_index":287,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Insolubility (solubility) index","parameters_en":[{"name":"Range","range":"(0,1 – 3,0) ml"}],"search_en":"Milk powder Insolubility (solubility) index Centrifugal method Classical Analyses Laboratory Range ISO 8156:2005 IDF-FIL 129:2005 ADPI, Section 1, 2016","technique_en":"Centrifugal method","test_object_en":"Milk powder","parameters_zh":[{"name":"范围","range":"(0,1 – 3,0) ml"}],"search_zh":"乳粉 不溶性（溶解度）指数 离心法 经典分析实验室 范围 ISO 8156:2005 IDF-FIL 129:2005 ADPI, Section 1, 2016","lab_section_zh":"经典分析实验室","test_object_zh":"乳粉","methodology_zh":"不溶性（溶解度）指数","technique_zh":"离心法"},{"_id":"6a7d76396040ebab2620d397","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Mleko w proszku","methodology":"Wskaźnik czystości (cząstki przypalone)","parameters":[{"name":"Zakres","range":"A – D"}],"technique":"Metoda filtracyjna","techniques":["Metoda filtracyjna"],"computed":[],"activity":"Wskaźnik czystości (cząstki przypalone)\nZakres A – D\nMetoda filtracyjna","reference":"ADPI, Section 1, 2016","norm_bases":["ADPI, Section 1, 2016"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko w proszku Wskaźnik czystości (cząstki przypalone)\nZakres A – D\nMetoda filtracyjna ADPI, Section 1, 2016 Mleko w proszku Wskaznik czystosci (czastki przypalone)\nZakres A – D\nMetoda filtracyjna ADPI, Section 1, 2016","categories":["food"],"row_index":288,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Cleanliness index (scorched particles)","parameters_en":[{"name":"Range","range":"A – D"}],"search_en":"Milk powder Cleanliness index (scorched particles) Filtration method Classical Analyses Laboratory Range ADPI, Section 1, 2016","technique_en":"Filtration method","test_object_en":"Milk powder","parameters_zh":[{"name":"范围","range":"A – D"}],"search_zh":"乳粉 过滤法 经典分析实验室 范围 ADPI, Section 1, 2016","lab_section_zh":"经典分析实验室","test_object_zh":"乳粉","technique_zh":"过滤法"},{"_id":"6a7d76396040ebab2620d398","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Oleje i tłuszcze roślinne oraz zwierzęce","methodology":"Zawartość zanieczyszczeń nierozpuszczalnych","parameters":[{"name":"Zakres","range":"(0,01 – 0,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń nierozpuszczalnych\nZakres (0,01 – 0,5) %\nMetoda wagowa","reference":"PN-EN ISO 663:2017-03 | ISO 663:2017-03","norm_bases":["PN-EN ISO 663:2017-03","ISO 663:2017-03"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oleje i tłuszcze roślinne oraz zwierzęce Zawartość zanieczyszczeń nierozpuszczalnych\nZakres (0,01 – 0,5) %\nMetoda wagowa PN-EN ISO 663:2017-03 | ISO 663:2017-03 Oleje i tluszcze roslinne oraz zwierzece Zawartosc zanieczyszczen nierozpuszczalnych\nZakres (0,01 – 0,5) %\nMetoda wagowa PN-EN ISO 663:2017-03 | ISO 663:2017-03","categories":["food","petro"],"row_index":289,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Insoluble impurity content","parameters_en":[{"name":"Range","range":"(0,01 – 0,5) %"}],"search_en":"Vegetable and animal oils and fats Insoluble impurity content Gravimetric method Classical Analyses Laboratory Range PN-EN ISO 663:2017-03 | ISO 663:2017-03","technique_en":"Gravimetric method","test_object_en":"Vegetable and animal oils and fats","parameters_zh":[{"name":"范围","range":"(0,01 – 0,5) %"}],"search_zh":"植物油脂与动物油脂 不溶性杂质含量 重量法 经典分析实验室 范围 PN-EN ISO 663:2017-03 | ISO 663:2017-03","technique_zh":"重量法","lab_section_zh":"经典分析实验室","test_object_zh":"植物油脂与动物油脂","methodology_zh":"不溶性杂质含量"},{"_id":"6a7d76396040ebab2620d399","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Oleje i tłuszcze roślinne oraz zwierzęce","methodology":"Liczba anizydynowa","parameters":[{"name":"Zakres","range":"0,5 – 11,0"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Liczba anizydynowa\nZakres 0,5 – 11,0\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6885:2016-04","norm_bases":["PN-EN ISO 6885:2016-04"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oleje i tłuszcze roślinne oraz zwierzęce Liczba anizydynowa\nZakres 0,5 – 11,0\nMetoda spektrofotometryczna PN-EN ISO 6885:2016-04 Oleje i tluszcze roslinne oraz zwierzece Liczba anizydynowa\nZakres 0,5 – 11,0\nMetoda spektrofotometryczna PN-EN ISO 6885:2016-04","categories":["food","petro"],"row_index":290,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Anisidine value","parameters_en":[{"name":"Range","range":"0,5 – 11,0"}],"search_en":"Vegetable and animal oils and fats Anisidine value Spectrophotometric method Classical Analyses Laboratory Range PN-EN ISO 6885:2016-04","technique_en":"Spectrophotometric method","test_object_en":"Vegetable and animal oils and fats","parameters_zh":[{"name":"范围","range":"0,5 – 11,0"}],"search_zh":"植物油脂与动物油脂 茴香胺值 分光光度法 经典分析实验室 范围 PN-EN ISO 6885:2016-04","technique_zh":"分光光度法","lab_section_zh":"经典分析实验室","test_object_zh":"植物油脂与动物油脂","methodology_zh":"茴香胺值"},{"_id":"6a7d76396040ebab2620d39a","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Owoce i warzywa, Przetwory owocowo-warzywne","methodology":"Zawartość dwutlenku siarki","parameters":[{"name":"Zakres","range":"(10 – 3000) mg/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość dwutlenku siarki\nZakres (10 – 3000) mg/kg\nMetoda miareczkowa","reference":"PN-90/A-75101/23+Az2:2002","norm_bases":["PN-90/A-75101/23+Az2:2002"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Owoce i warzywa, Przetwory owocowo-warzywne Zawartość dwutlenku siarki\nZakres (10 – 3000) mg/kg\nMetoda miareczkowa PN-90/A-75101/23+Az2:2002 Owoce i warzywa, Przetwory owocowo-warzywne Zawartosc dwutlenku siarki\nZakres (10 – 3000) mg/kg\nMetoda miareczkowa PN-90/A-75101/23+Az2:2002","categories":["other"],"row_index":291,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Sulfur dioxide content","parameters_en":[{"name":"Range","range":"(10 – 3000) mg/kg"}],"search_en":"Fruit and vegetables, Fruit-vegetable products Sulfur dioxide content Titrimetric method Classical Analyses Laboratory Range PN-90/A-75101/23+Az2:2002","technique_en":"Titrimetric method","test_object_en":"Fruit and vegetables, Fruit-vegetable products","parameters_zh":[{"name":"范围","range":"(10 – 3000) mg/kg"}],"search_zh":"二氧化硫含量 滴定法 经典分析实验室 范围 PN-90/A-75101/23+Az2:2002","technique_zh":"滴定法","lab_section_zh":"经典分析实验室","methodology_zh":"二氧化硫含量"},{"_id":"6a7d76396040ebab2620d39b","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Mięso i produkty mięsne","methodology":"Zawartość kolagenu","parameters":[{"name":"Zakres","range":"(0,8 – 10) %"},{"name":"Zawartość tkanki łącznej (stosunek zawartości kolagenu do zawartości białka w mięsie)"},{"name":"Zakres","range":"(3 – 30) %"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość kolagenu\nZakres:\nZakres (0,8 – 10) %\nZawartość tkanki łącznej (stosunek zawartości kolagenu do zawartości białka w mięsie)\nZakres (3 – 30) %\n(z obliczeń)","reference":"Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 1169/2011 z dn. 25.10.2011 r.","norm_bases":["Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 1169/2011 z dn. 25.10.2011 r."],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i produkty mięsne Zawartość kolagenu\nZakres:\nZakres (0,8 – 10) %\nZawartość tkanki łącznej (stosunek zawartości kolagenu do zawartości białka w mięsie)\nZakres (3 – 30) %\n(z obliczeń) Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 1169/2011 z dn. 25.10.2011 r. Mieso i produkty miesne Zawartosc kolagenu\nZakres:\nZakres (0,8 – 10) %\nZawartosc tkanki lacznej (stosunek zawartosci kolagenu do zawartosci bialka w miesie)\nZakres (3 – 30) %\n(z obliczen) Rozporzadzenie Parlamentu Europejskiego i Rady (UE) Nr 1169/2011 z dn. 25.10.2011 r.","categories":["food"],"row_index":292,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Collagen content","parameters_en":[{"name":"Range","range":"(0,8 – 10) %"},{"name":"Connective tissue content (ratio of collagen content to protein content in meat)"},{"name":"Range","range":"(3 – 30) %"},{"name":"(calculated)"}],"search_en":"Meat and meat products Collagen content Classical Analyses Laboratory Range Connective tissue content (ratio of collagen content to protein content in meat) Range (calculated) Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 1169/2011 z dn. 25.10.2011 r.","test_object_en":"Meat and meat products","parameters_zh":[{"name":"范围","range":"(0,8 – 10) %"},{"name":"Zawartość tkanki łącznej (stosunek zawartości kolagenu do zawartości białka w mięsie)"},{"name":"范围","range":"(3 – 30) %"},{"name":"（计算得出）"}],"search_zh":"肉与肉制品 胶原蛋白含量 经典分析实验室 范围 范围 （计算得出） Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 1169/2011 z dn. 25.10.2011 r.","lab_section_zh":"经典分析实验室","test_object_zh":"肉与肉制品","methodology_zh":"胶原蛋白含量"},{"_id":"6a7d76396040ebab2620d39c","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Mięso i produkty mięsne","methodology":"Zawartość hydroksyproliny","parameters":[{"name":"Zakres","range":"(0,1 – 1,25) %"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość hydroksyproliny\nZakres (0,1 – 1,25) %\nMetoda spektrofotometryczna","reference":"PN-ISO 3496:2000 | ISO 3496:1994","norm_bases":["PN-ISO 3496:2000","ISO 3496:1994"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i produkty mięsne Zawartość hydroksyproliny\nZakres (0,1 – 1,25) %\nMetoda spektrofotometryczna PN-ISO 3496:2000 | ISO 3496:1994 Mieso i produkty miesne Zawartosc hydroksyproliny\nZakres (0,1 – 1,25) %\nMetoda spektrofotometryczna PN-ISO 3496:2000 | ISO 3496:1994","categories":["food"],"row_index":293,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Hydroxyproline content","parameters_en":[{"name":"Range","range":"(0,1 – 1,25) %"}],"search_en":"Meat and meat products Hydroxyproline content Spectrophotometric method Classical Analyses Laboratory Range PN-ISO 3496:2000 | ISO 3496:1994","technique_en":"Spectrophotometric method","test_object_en":"Meat and meat products","parameters_zh":[{"name":"范围","range":"(0,1 – 1,25) %"}],"search_zh":"肉与肉制品 羟脯氨酸含量 分光光度法 经典分析实验室 范围 PN-ISO 3496:2000 | ISO 3496:1994","technique_zh":"分光光度法","lab_section_zh":"经典分析实验室","test_object_zh":"肉与肉制品","methodology_zh":"羟脯氨酸含量"},{"_id":"6a7d76396040ebab2620d39d","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Oleje i tłuszcze roślinne oraz zwierzęce","methodology":"Liczba nadtlenkowa","parameters":[{"name":"Zakres","range":"(0,1 – 30) meq/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba nadtlenkowa\nZakres (0,1 – 30) meq/kg\nMetoda miareczkowa","reference":"PN-EN ISO 3960:2017-03 | ISO 3960:2017-03","norm_bases":["PN-EN ISO 3960:2017-03","ISO 3960:2017-03"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oleje i tłuszcze roślinne oraz zwierzęce Liczba nadtlenkowa\nZakres (0,1 – 30) meq/kg\nMetoda miareczkowa PN-EN ISO 3960:2017-03 | ISO 3960:2017-03 Oleje i tluszcze roslinne oraz zwierzece Liczba nadtlenkowa\nZakres (0,1 – 30) meq/kg\nMetoda miareczkowa PN-EN ISO 3960:2017-03 | ISO 3960:2017-03","categories":["food","petro"],"row_index":294,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Peroxide value","parameters_en":[{"name":"Range","range":"(0,1 – 30) meq/kg"}],"search_en":"Vegetable and animal oils and fats Peroxide value Titrimetric method Classical Analyses Laboratory Range PN-EN ISO 3960:2017-03 | ISO 3960:2017-03","technique_en":"Titrimetric method","test_object_en":"Vegetable and animal oils and fats","parameters_zh":[{"name":"范围","range":"(0,1 – 30) meq/kg"}],"search_zh":"植物油脂与动物油脂 过氧化值 滴定法 经典分析实验室 范围 PN-EN ISO 3960:2017-03 | ISO 3960:2017-03","technique_zh":"滴定法","lab_section_zh":"经典分析实验室","methodology_zh":"过氧化值","test_object_zh":"植物油脂与动物油脂"},{"_id":"6a7d76396040ebab2620d39e","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Oleje i tłuszcze roślinne oraz zwierzęce","methodology":"Liczba jodowa","parameters":[{"name":"Zakres","range":"(5 – 180) g/100 g"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba jodowa\nZakres (5 – 180) g/100 g\nMetoda miareczkowa","reference":"PN-EN ISO 3961:2025-07","norm_bases":["PN-EN ISO 3961:2025-07"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oleje i tłuszcze roślinne oraz zwierzęce Liczba jodowa\nZakres (5 – 180) g/100 g\nMetoda miareczkowa PN-EN ISO 3961:2025-07 Oleje i tluszcze roslinne oraz zwierzece Liczba jodowa\nZakres (5 – 180) g/100 g\nMetoda miareczkowa PN-EN ISO 3961:2025-07","categories":["food","petro"],"row_index":295,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Iodine value","parameters_en":[{"name":"Range","range":"(5 – 180) g/100 g"}],"search_en":"Vegetable and animal oils and fats Iodine value Titrimetric method Classical Analyses Laboratory Range PN-EN ISO 3961:2025-07","technique_en":"Titrimetric method","test_object_en":"Vegetable and animal oils and fats","parameters_zh":[{"name":"范围","range":"(5 – 180) g/100 g"}],"search_zh":"植物油脂与动物油脂 碘值 滴定法 经典分析实验室 范围 PN-EN ISO 3961:2025-07","technique_zh":"滴定法","lab_section_zh":"经典分析实验室","test_object_zh":"植物油脂与动物油脂","methodology_zh":"碘值"},{"_id":"6a7d76396040ebab2620d39f","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Oleje i tłuszcze roślinne oraz zwierzęce","methodology":"Umowny stosunek masy do objętości („ciężar” litra w powietrzu)","parameters":[{"name":"Zakres","range":"(0,7000 – 1,0000) g/ml"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Umowny stosunek masy do objętości („ciężar” litra w powietrzu)\nZakres (0,7000 – 1,0000) g/ml\nMetoda wagowa","reference":"PN-EN ISO 6883:2017-03","norm_bases":["PN-EN ISO 6883:2017-03"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oleje i tłuszcze roślinne oraz zwierzęce Umowny stosunek masy do objętości („ciężar” litra w powietrzu)\nZakres (0,7000 – 1,0000) g/ml\nMetoda wagowa PN-EN ISO 6883:2017-03 Oleje i tluszcze roslinne oraz zwierzece Umowny stosunek masy do objetosci („ciezar” litra w powietrzu)\nZakres (0,7000 – 1,0000) g/ml\nMetoda wagowa PN-EN ISO 6883:2017-03","categories":["food","petro"],"row_index":296,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Conventional mass to volume ratio (“weight” of a litre in air)","parameters_en":[{"name":"Range","range":"(0,7000 – 1,0000) g/ml"}],"search_en":"Vegetable and animal oils and fats Conventional mass to volume ratio (“weight” of a litre in air) Gravimetric method Classical Analyses Laboratory Range PN-EN ISO 6883:2017-03","technique_en":"Gravimetric method","test_object_en":"Vegetable and animal oils and fats","parameters_zh":[{"name":"范围","range":"(0,7000 – 1,0000) g/ml"}],"search_zh":"植物油脂与动物油脂 重量法 经典分析实验室 范围 PN-EN ISO 6883:2017-03","technique_zh":"重量法","lab_section_zh":"经典分析实验室","test_object_zh":"植物油脂与动物油脂"},{"_id":"6a7d76396040ebab2620d3a0","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Oleje i tłuszcze roślinne oraz zwierzęce","methodology":"Zawartość wolnych kwasów tłuszczowych","parameters":[{"name":"Zakres","range":"(0,01 – 8,0) %"},{"name":"Liczba kwasowa"},{"name":"Zakres","range":"(0,02 – 16,0) mg KOH/g"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość wolnych kwasów tłuszczowych\nZakres:\nZakres (0,01 – 8,0) %\nLiczba kwasowa\nZakres (0,02 – 16,0) mg KOH/g\nMetoda miareczkowa","reference":"PN-EN ISO 660:2021-03 | ISO 660:2020","norm_bases":["PN-EN ISO 660:2021-03","ISO 660:2020"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oleje i tłuszcze roślinne oraz zwierzęce Zawartość wolnych kwasów tłuszczowych\nZakres:\nZakres (0,01 – 8,0) %\nLiczba kwasowa\nZakres (0,02 – 16,0) mg KOH/g\nMetoda miareczkowa PN-EN ISO 660:2021-03 | ISO 660:2020 Oleje i tluszcze roslinne oraz zwierzece Zawartosc wolnych kwasow tluszczowych\nZakres:\nZakres (0,01 – 8,0) %\nLiczba kwasowa\nZakres (0,02 – 16,0) mg KOH/g\nMetoda miareczkowa PN-EN ISO 660:2021-03 | ISO 660:2020","categories":["food","petro"],"row_index":297,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Content of free fatty acids","parameters_en":[{"name":"Range","range":"(0,01 – 8,0) %"},{"name":"Acid value"},{"name":"Range","range":"(0,02 – 16,0) mg KOH/g"}],"search_en":"Vegetable and animal oils and fats Content of free fatty acids Titrimetric method Classical Analyses Laboratory Range Acid value Range PN-EN ISO 660:2021-03 | ISO 660:2020","technique_en":"Titrimetric method","test_object_en":"Vegetable and animal oils and fats","parameters_zh":[{"name":"范围","range":"(0,01 – 8,0) %"},{"name":"酸值"},{"name":"范围","range":"(0,02 – 16,0) mg KOH/g"}],"search_zh":"植物油脂与动物油脂 滴定法 经典分析实验室 范围 酸值 范围 PN-EN ISO 660:2021-03 | ISO 660:2020","technique_zh":"滴定法","lab_section_zh":"经典分析实验室","test_object_zh":"植物油脂与动物油脂"},{"_id":"6a7d76396040ebab2620d3a1","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Oleje i tłuszcze roślinne oraz zwierzęce","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,05 – 2,0) % (m/m)"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (0,05 – 2,0) % (m/m)\nMetoda miareczkowania potencjometrycznego","reference":"PN-EN ISO 8534:2017-03","norm_bases":["PN-EN ISO 8534:2017-03"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oleje i tłuszcze roślinne oraz zwierzęce Zawartość wody\nZakres (0,05 – 2,0) % (m/m)\nMetoda miareczkowania potencjometrycznego PN-EN ISO 8534:2017-03 Oleje i tluszcze roslinne oraz zwierzece Zawartosc wody\nZakres (0,05 – 2,0) % (m/m)\nMetoda miareczkowania potencjometrycznego PN-EN ISO 8534:2017-03","categories":["water","food","petro"],"row_index":298,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(0,05 – 2,0) % (m/m)"}],"search_en":"Vegetable and animal oils and fats Water content Potentiometric titration method Classical Analyses Laboratory Range PN-EN ISO 8534:2017-03","technique_en":"Potentiometric titration method","test_object_en":"Vegetable and animal oils and fats","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,05 – 2,0) % (m/m)"}],"search_zh":"植物油脂与动物油脂 水分含量 电位滴定法 经典分析实验室 范围 PN-EN ISO 8534:2017-03","technique_zh":"电位滴定法","lab_section_zh":"经典分析实验室","test_object_zh":"植物油脂与动物油脂"},{"_id":"6a7d76396040ebab2620d3a2","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Pasze dla zwierząt, Śruty","methodology":"Zawartość włókna surowego (błonnika)","parameters":[{"name":"Zakres","range":"(0,2 – 25) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość włókna surowego (błonnika)\nZakres (0,2 – 25) %\nMetoda wagowa","reference":"PN-EN ISO 6865:2002","norm_bases":["PN-EN ISO 6865:2002"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze dla zwierząt, Śruty Zawartość włókna surowego (błonnika)\nZakres (0,2 – 25) %\nMetoda wagowa PN-EN ISO 6865:2002 Pasze dla zwierzat, Sruty Zawartosc wlokna surowego (blonnika)\nZakres (0,2 – 25) %\nMetoda wagowa PN-EN ISO 6865:2002","categories":["food"],"row_index":299,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Crude fibre (dietary fibre) content","parameters_en":[{"name":"Range","range":"(0,2 – 25) %"}],"search_en":"Animal feed, Meals Crude fibre (dietary fibre) content Gravimetric method Classical Analyses Laboratory Range PN-EN ISO 6865:2002","technique_en":"Gravimetric method","test_object_en":"Animal feed, Meals","parameters_zh":[{"name":"范围","range":"(0,2 – 25) %"}],"search_zh":"重量法 经典分析实验室 范围 PN-EN ISO 6865:2002","technique_zh":"重量法","lab_section_zh":"经典分析实验室"},{"_id":"6a7d76396040ebab2620d3a3","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Pasze dla zwierząt, Śruty","methodology":"Zawartość skrobi","parameters":[{"name":"Zakres","range":"(1,0 – 80) %"}],"technique":"Metoda polarymetryczna","techniques":["Metoda polarymetryczna"],"computed":[],"activity":"Zawartość skrobi\nZakres (1,0 – 80) %\nMetoda polarymetryczna","reference":"ISO 6493:2000 | PN-R-64785:1994","norm_bases":["ISO 6493:2000","PN-R-64785:1994"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze dla zwierząt, Śruty Zawartość skrobi\nZakres (1,0 – 80) %\nMetoda polarymetryczna ISO 6493:2000 | PN-R-64785:1994 Pasze dla zwierzat, Sruty Zawartosc skrobi\nZakres (1,0 – 80) %\nMetoda polarymetryczna ISO 6493:2000 | PN-R-64785:1994","categories":["food"],"row_index":300,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Starch content","parameters_en":[{"name":"Range","range":"(1,0 – 80) %"}],"search_en":"Animal feed, Meals Starch content Polarimetric method Classical Analyses Laboratory Range ISO 6493:2000 | PN-R-64785:1994","technique_en":"Polarimetric method","test_object_en":"Animal feed, Meals","parameters_zh":[{"name":"范围","range":"(1,0 – 80) %"}],"search_zh":"淀粉含量 旋光法 经典分析实验室 范围 ISO 6493:2000 | PN-R-64785:1994","lab_section_zh":"经典分析实验室","methodology_zh":"淀粉含量","technique_zh":"旋光法"},{"_id":"6a7d76396040ebab2620d3a4","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Produkty mleczne: serwatka w proszku","methodology":"Wskaźnik nierozpuszczalności (rozpuszczalności)","parameters":[{"name":"Zakres","range":"(0,1 – 3,0) ml"}],"technique":"Metoda wirówkowa","techniques":["Metoda wirówkowa"],"computed":[],"activity":"Wskaźnik nierozpuszczalności (rozpuszczalności)\nZakres (0,1 – 3,0) ml\nMetoda wirówkowa","reference":"PB-26 wyd. III z dn. 04.02.2009","norm_bases":["PB-26 wyd. III z dn. 04.02.2009"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Produkty mleczne: serwatka w proszku Wskaźnik nierozpuszczalności (rozpuszczalności)\nZakres (0,1 – 3,0) ml\nMetoda wirówkowa PB-26 wyd. III z dn. 04.02.2009 Produkty mleczne: serwatka w proszku Wskaznik nierozpuszczalnosci (rozpuszczalnosci)\nZakres (0,1 – 3,0) ml\nMetoda wirowkowa PB-26 wyd. III z dn. 04.02.2009","categories":["other"],"row_index":301,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Insolubility (solubility) index","parameters_en":[{"name":"Range","range":"(0,1 – 3,0) ml"}],"search_en":"Milk products: whey powder Insolubility (solubility) index Centrifugal method Classical Analyses Laboratory Range PB-26 wyd. III z dn. 04.02.2009","technique_en":"Centrifugal method","test_object_en":"Milk products: whey powder","parameters_zh":[{"name":"范围","range":"(0,1 – 3,0) ml"}],"search_zh":"乳制品：乳清粉 不溶性（溶解度）指数 离心法 经典分析实验室 范围 PB-26 wyd. III z dn. 04.02.2009","lab_section_zh":"经典分析实验室","methodology_zh":"不溶性（溶解度）指数","technique_zh":"离心法","test_object_zh":"乳制品：乳清粉"},{"_id":"6a7d76396040ebab2620d3a5","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Produkty mleczne: serwatka w proszku","methodology":"Cząstki przypalone","parameters":[{"name":"Zakres","range":"A – D"}],"technique":"Metoda filtracyjna","techniques":["Metoda filtracyjna"],"computed":[],"activity":"Cząstki przypalone\nZakres A – D\nMetoda filtracyjna","reference":"PB-31 wyd. III z dn. 04.02.2009","norm_bases":["PB-31 wyd. III z dn. 04.02.2009"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Produkty mleczne: serwatka w proszku Cząstki przypalone\nZakres A – D\nMetoda filtracyjna PB-31 wyd. III z dn. 04.02.2009 Produkty mleczne: serwatka w proszku Czastki przypalone\nZakres A – D\nMetoda filtracyjna PB-31 wyd. III z dn. 04.02.2009","categories":["other"],"row_index":302,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Scorched particles","parameters_en":[{"name":"Range","range":"A – D"}],"search_en":"Milk products: whey powder Scorched particles Filtration method Classical Analyses Laboratory Range PB-31 wyd. III z dn. 04.02.2009","technique_en":"Filtration method","test_object_en":"Milk products: whey powder","parameters_zh":[{"name":"范围","range":"A – D"}],"search_zh":"乳制品：乳清粉 过滤法 经典分析实验室 范围 PB-31 wyd. III z dn. 04.02.2009","lab_section_zh":"经典分析实验室","technique_zh":"过滤法","test_object_zh":"乳制品：乳清粉"},{"_id":"6a7d76396040ebab2620d3a6","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Produkty mleczne: śmietana w proszku","methodology":"Wskaźnik nierozpuszczalności (rozpuszczalności)","parameters":[{"name":"Zakres","range":"(0,1 – 3,0) ml"}],"technique":"Metoda wirówkowa","techniques":["Metoda wirówkowa"],"computed":[],"activity":"Wskaźnik nierozpuszczalności (rozpuszczalności)\nZakres (0,1 – 3,0) ml\nMetoda wirówkowa","reference":"ISO 8156:2005 IDF-FIL 129:2005","norm_bases":["ISO 8156:2005 IDF-FIL 129:2005"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Produkty mleczne: śmietana w proszku Wskaźnik nierozpuszczalności (rozpuszczalności)\nZakres (0,1 – 3,0) ml\nMetoda wirówkowa ISO 8156:2005 IDF-FIL 129:2005 Produkty mleczne: smietana w proszku Wskaznik nierozpuszczalnosci (rozpuszczalnosci)\nZakres (0,1 – 3,0) ml\nMetoda wirowkowa ISO 8156:2005 IDF-FIL 129:2005","categories":["other"],"row_index":303,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Insolubility (solubility) index","parameters_en":[{"name":"Range","range":"(0,1 – 3,0) ml"}],"search_en":"Milk products: cream powder Insolubility (solubility) index Centrifugal method Classical Analyses Laboratory Range ISO 8156:2005 IDF-FIL 129:2005","technique_en":"Centrifugal method","test_object_en":"Milk products: cream powder","parameters_zh":[{"name":"范围","range":"(0,1 – 3,0) ml"}],"search_zh":"不溶性（溶解度）指数 离心法 经典分析实验室 范围 ISO 8156:2005 IDF-FIL 129:2005","lab_section_zh":"经典分析实验室","methodology_zh":"不溶性（溶解度）指数","technique_zh":"离心法"},{"_id":"6a7d76396040ebab2620d3a7","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Mleko i przetwory mleczne, Napoje alkoholowe, Wino, Piwo, Napoje bezalkoholowe, Płynne koncentraty spożywcze, Płynne suplementy diety, Oleje","methodology":"Gęstość","parameters":[{"name":"Zakres","range":"(0,8000 – 1,3200) g/cm3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość\nZakres (0,8000 – 1,3200) g/cm3\nMetoda oscylacyjna","reference":"PB-381 wyd. 2 z dn. 01.12.2021","norm_bases":["PB-381 wyd. 2 z dn. 01.12.2021"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko i przetwory mleczne, Napoje alkoholowe, Wino, Piwo, Napoje bezalkoholowe, Płynne koncentraty spożywcze, Płynne suplementy diety, Oleje Gęstość\nZakres (0,8000 – 1,3200) g/cm3\nMetoda oscylacyjna PB-381 wyd. 2 z dn. 01.12.2021 Mleko i przetwory mleczne, Napoje alkoholowe, Wino, Piwo, Napoje bezalkoholowe, Plynne koncentraty spozywcze, Plynne suplementy diety, Oleje Gestosc\nZakres (0,8000 – 1,3200) g/cm3\nMetoda oscylacyjna PB-381 wyd. 2 z dn. 01.12.2021","categories":["food","petro","pharma"],"row_index":304,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Density","parameters_en":[{"name":"Range","range":"(0,8000 – 1,3200) g/cm3"}],"search_en":"Milk and dairy products, Alcoholic beverages, Wine, Beer, Non-alcoholic beverages, Liquid food concentrates, Liquid food supplements, Oils Density Oscillation method Classical Analyses Laboratory Range PB-381 wyd. 2 z dn. 01.12.2021","technique_en":"Oscillation method","test_object_en":"Milk and dairy products, Alcoholic beverages, Wine, Beer, Non-alcoholic beverages, Liquid food concentrates, Liquid food supplements, Oils","methodology_zh":"密度","parameters_zh":[{"name":"范围","range":"(0,8000 – 1,3200) g/cm3"}],"search_zh":"密度 振荡法 经典分析实验室 范围 PB-381 wyd. 2 z dn. 01.12.2021","technique_zh":"振荡法","lab_section_zh":"经典分析实验室"},{"_id":"6a7d76396040ebab2620d3a8","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Wyroby spirytusowe (spirytus, napoje spirytusowe)","methodology":"Gęstość","parameters":[{"name":"Zakres","range":"(0,8000 – 1,1000) g/cm3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość\nZakres (0,8000 – 1,1000) g/cm3\nMetoda oscylacyjna","reference":"PN-A-79529-4:2005 p. 6.2","norm_bases":["PN-A-79529-4:2005 p. 6.2"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby spirytusowe (spirytus, napoje spirytusowe) Gęstość\nZakres (0,8000 – 1,1000) g/cm3\nMetoda oscylacyjna PN-A-79529-4:2005 p. 6.2 Wyroby spirytusowe (spirytus, napoje spirytusowe) Gestosc\nZakres (0,8000 – 1,1000) g/cm3\nMetoda oscylacyjna PN-A-79529-4:2005 p. 6.2","categories":["food"],"row_index":305,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Density","parameters_en":[{"name":"Range","range":"(0,8000 – 1,1000) g/cm3"}],"search_en":"Spirit products (rectified spirit, spirit drinks) Density Oscillation method Classical Analyses Laboratory Range PN-A-79529-4:2005 p. 6.2","technique_en":"Oscillation method","test_object_en":"Spirit products (rectified spirit, spirit drinks)","methodology_zh":"密度","parameters_zh":[{"name":"范围","range":"(0,8000 – 1,1000) g/cm3"}],"search_zh":"密度 振荡法 经典分析实验室 范围 PN-A-79529-4:2005 p. 6.2","technique_zh":"振荡法","lab_section_zh":"经典分析实验室"},{"_id":"6a7d76396040ebab2620d3a9","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Przetwory owocowo-warzywne","methodology":"Zawartość ekstraktu ogólnego","parameters":[{"name":"Zakres","range":"(4,0 – 40,0) % (m/m)"}],"technique":"Metoda refraktometryczna","techniques":["Metoda refraktometryczna"],"computed":[],"activity":"Zawartość ekstraktu ogólnego\nZakres (4,0 – 40,0) % (m/m)\nMetoda refraktometryczna","reference":"PN-A-75101-02:1990+Az1:2002 p. 2","norm_bases":["PN-A-75101-02:1990+Az1:2002 p. 2"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory owocowo-warzywne Zawartość ekstraktu ogólnego\nZakres (4,0 – 40,0) % (m/m)\nMetoda refraktometryczna PN-A-75101-02:1990+Az1:2002 p. 2 Przetwory owocowo-warzywne Zawartosc ekstraktu ogolnego\nZakres (4,0 – 40,0) % (m/m)\nMetoda refraktometryczna PN-A-75101-02:1990+Az1:2002 p. 2","categories":["other"],"row_index":306,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Total extract content","parameters_en":[{"name":"Range","range":"(4,0 – 40,0) % (m/m)"}],"search_en":"Fruit and vegetable preserves Total extract content Refractometric method Classical Analyses Laboratory Range PN-A-75101-02:1990+Az1:2002 p. 2","technique_en":"Refractometric method","test_object_en":"Fruit and vegetable preserves","parameters_zh":[{"name":"范围","range":"(4,0 – 40,0) % (m/m)"}],"search_zh":"果蔬制品 总浸出物含量 折射法 经典分析实验室 范围 PN-A-75101-02:1990+Az1:2002 p. 2","technique_zh":"折射法","lab_section_zh":"经典分析实验室","methodology_zh":"总浸出物含量","test_object_zh":"果蔬制品"},{"_id":"6a7d76396040ebab2620d3aa","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Napoje bezalkoholowe","methodology":"Zawartość ekstraktu ogólnego","parameters":[{"name":"Zakres","range":"(0,2 – 12,0) % (m/m)"}],"technique":"Metoda refraktometryczna","techniques":["Metoda refraktometryczna"],"computed":[],"activity":"Zawartość ekstraktu ogólnego\nZakres (0,2 – 12,0) % (m/m)\nMetoda refraktometryczna","reference":"PN-A-79033:1985 p. 3.6.1","norm_bases":["PN-A-79033:1985 p. 3.6.1"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje bezalkoholowe Zawartość ekstraktu ogólnego\nZakres (0,2 – 12,0) % (m/m)\nMetoda refraktometryczna PN-A-79033:1985 p. 3.6.1 Napoje bezalkoholowe Zawartosc ekstraktu ogolnego\nZakres (0,2 – 12,0) % (m/m)\nMetoda refraktometryczna PN-A-79033:1985 p. 3.6.1","categories":["food"],"row_index":307,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Total extract content","parameters_en":[{"name":"Range","range":"(0,2 – 12,0) % (m/m)"}],"search_en":"Non-alcoholic beverages Total extract content Refractometric method Classical Analyses Laboratory Range PN-A-79033:1985 p. 3.6.1","technique_en":"Refractometric method","test_object_en":"Non-alcoholic beverages","parameters_zh":[{"name":"范围","range":"(0,2 – 12,0) % (m/m)"}],"search_zh":"无酒精饮料 总浸出物含量 折射法 经典分析实验室 范围 PN-A-79033:1985 p. 3.6.1","technique_zh":"折射法","lab_section_zh":"经典分析实验室","test_object_zh":"无酒精饮料","methodology_zh":"总浸出物含量"},{"_id":"6a7d76396040ebab2620d3ab","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Wyroby cukiernicze","methodology":"Zawartość alkoholu","parameters":[{"name":"Zakres","range":"(0,05 – 5,5) g/100g"}],"technique":"Metoda piknometryczna","techniques":["Metoda piknometryczna"],"computed":[],"activity":"Zawartość alkoholu\nZakres (0,05 – 5,5) g/100g\nMetoda piknometryczna","reference":"PN-A-88026:1981","norm_bases":["PN-A-88026:1981"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby cukiernicze Zawartość alkoholu\nZakres (0,05 – 5,5) g/100g\nMetoda piknometryczna PN-A-88026:1981 Wyroby cukiernicze Zawartosc alkoholu\nZakres (0,05 – 5,5) g/100g\nMetoda piknometryczna PN-A-88026:1981","categories":["food"],"row_index":308,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Alcohol content","parameters_en":[{"name":"Range","range":"(0,05 – 5,5) g/100g"}],"search_en":"Confectionery products Alcohol content Pycnometric method Classical Analyses Laboratory Range PN-A-88026:1981","technique_en":"Pycnometric method","test_object_en":"Confectionery products","parameters_zh":[{"name":"范围","range":"(0,05 – 5,5) g/100g"}],"search_zh":"糖果制品 酒精含量 比重瓶法 经典分析实验室 范围 PN-A-88026:1981","test_object_zh":"糖果制品","lab_section_zh":"经典分析实验室","technique_zh":"比重瓶法","methodology_zh":"酒精含量"},{"_id":"6a7d76396040ebab2620d3ac","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Soki owocowe i warzywne, nektary","methodology":"Gęstość względna 20 °C /20 °C","parameters":[{"name":"Zakres","range":"(1,0000 – 1,1000) g/cm3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Gęstość względna 20 °C /20 °C\nZakres (1,0000 – 1,1000) g/cm3\nMetoda wagowa","reference":"PN-EN 1131:1999","norm_bases":["PN-EN 1131:1999"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Soki owocowe i warzywne, nektary Gęstość względna 20 °C /20 °C\nZakres (1,0000 – 1,1000) g/cm3\nMetoda wagowa PN-EN 1131:1999 Soki owocowe i warzywne, nektary Gestosc wzgledna 20 °C /20 °C\nZakres (1,0000 – 1,1000) g/cm3\nMetoda wagowa PN-EN 1131:1999","categories":["other"],"row_index":309,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Relative density 20 °C /20 °C","parameters_en":[{"name":"Range","range":"(1,0000 – 1,1000) g/cm3"}],"search_en":"Fruit and vegetable juices, nectars Relative density 20 °C /20 °C Gravimetric method Classical Analyses Laboratory Range PN-EN 1131:1999","technique_en":"Gravimetric method","test_object_en":"Fruit and vegetable juices, nectars","parameters_zh":[{"name":"范围","range":"(1,0000 – 1,1000) g/cm3"}],"search_zh":"果汁与蔬菜汁、果蜜 重量法 经典分析实验室 范围 PN-EN 1131:1999","technique_zh":"重量法","lab_section_zh":"经典分析实验室","test_object_zh":"果汁与蔬菜汁、果蜜"},{"_id":"6a7d76396040ebab2620d3ad","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Soki owocowe i warzywne, nektary","methodology":"Gęstość","parameters":[{"name":"Zakres","range":"(1,0000 – 1,1000) g/cm3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Gęstość\nZakres (1,0000 – 1,1000) g/cm3\nMetoda wagowa","reference":"PN-EN 1131:1999","norm_bases":["PN-EN 1131:1999"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Soki owocowe i warzywne, nektary Gęstość\nZakres (1,0000 – 1,1000) g/cm3\nMetoda wagowa PN-EN 1131:1999 Soki owocowe i warzywne, nektary Gestosc\nZakres (1,0000 – 1,1000) g/cm3\nMetoda wagowa PN-EN 1131:1999","categories":["other"],"row_index":310,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Density","parameters_en":[{"name":"Range","range":"(1,0000 – 1,1000) g/cm3"}],"search_en":"Fruit and vegetable juices, nectars Density Gravimetric method Classical Analyses Laboratory Range PN-EN 1131:1999","technique_en":"Gravimetric method","test_object_en":"Fruit and vegetable juices, nectars","methodology_zh":"密度","parameters_zh":[{"name":"范围","range":"(1,0000 – 1,1000) g/cm3"}],"search_zh":"果汁与蔬菜汁、果蜜 密度 重量法 经典分析实验室 范围 PN-EN 1131:1999","technique_zh":"重量法","lab_section_zh":"经典分析实验室","test_object_zh":"果汁与蔬菜汁、果蜜"},{"_id":"6a7d76396040ebab2620d3ae","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Soki owocowe i warzywne, nektary","methodology":"Zawartość substancji rozpuszczalnych Zawartość ekstraktu ogólnego","parameters":[{"name":"Zakres","range":"(5,0 – 70,0) % (m/m)"}],"technique":"Metoda refraktometryczna","techniques":["Metoda refraktometryczna"],"computed":[],"activity":"Zawartość substancji rozpuszczalnych Zawartość ekstraktu ogólnego\nZakres (5,0 – 70,0) % (m/m)\nMetoda refraktometryczna","reference":"PN-EN 12143:2000","norm_bases":["PN-EN 12143:2000"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Soki owocowe i warzywne, nektary Zawartość substancji rozpuszczalnych Zawartość ekstraktu ogólnego\nZakres (5,0 – 70,0) % (m/m)\nMetoda refraktometryczna PN-EN 12143:2000 Soki owocowe i warzywne, nektary Zawartosc substancji rozpuszczalnych Zawartosc ekstraktu ogolnego\nZakres (5,0 – 70,0) % (m/m)\nMetoda refraktometryczna PN-EN 12143:2000","categories":["other"],"row_index":311,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Content of soluble substances Total extract content","parameters_en":[{"name":"Range","range":"(5,0 – 70,0) % (m/m)"}],"search_en":"Fruit and vegetable juices, nectars Content of soluble substances Total extract content Refractometric method Classical Analyses Laboratory Range PN-EN 12143:2000","technique_en":"Refractometric method","test_object_en":"Fruit and vegetable juices, nectars","parameters_zh":[{"name":"范围","range":"(5,0 – 70,0) % (m/m)"}],"search_zh":"果汁与蔬菜汁、果蜜 折射法 经典分析实验室 范围 PN-EN 12143:2000","technique_zh":"折射法","lab_section_zh":"经典分析实验室","test_object_zh":"果汁与蔬菜汁、果蜜"},{"_id":"6a7d76396040ebab2620d3af","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Bioetanol, Spirytus","methodology":"Kwasowość (w przeliczeniu na kwas octowy)","parameters":[{"name":"Zakres","range":"(0,003 – 0,030) g/l spirytusu 100 %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość (w przeliczeniu na kwas octowy)\nZakres (0,003 – 0,030) g/l spirytusu 100 %\nMetoda miareczkowa","reference":"PN-A-79528-7:2001","norm_bases":["PN-A-79528-7:2001"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Bioetanol, Spirytus Kwasowość (w przeliczeniu na kwas octowy)\nZakres (0,003 – 0,030) g/l spirytusu 100 %\nMetoda miareczkowa PN-A-79528-7:2001 Bioetanol, Spirytus Kwasowosc (w przeliczeniu na kwas octowy)\nZakres (0,003 – 0,030) g/l spirytusu 100 %\nMetoda miareczkowa PN-A-79528-7:2001","categories":["other"],"row_index":312,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Acidity (expressed as acetic acid)","parameters_en":[{"name":"Range","range":"(0,003 – 0,030) g/l spirytusu 100 %"}],"search_en":"Bioethanol, Spirit Acidity (expressed as acetic acid) Titrimetric method Classical Analyses Laboratory Range PN-A-79528-7:2001","technique_en":"Titrimetric method","test_object_en":"Bioethanol, Spirit","parameters_zh":[{"name":"范围","range":"(0,003 – 0,030) g/l spirytusu 100 %"}],"search_zh":"滴定法 经典分析实验室 范围 PN-A-79528-7:2001","technique_zh":"滴定法","lab_section_zh":"经典分析实验室"},{"_id":"6a7d76396040ebab2620d3b0","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Wędliny, Wyroby garmażeryjne, Ocet, Soki owocowe (w tym koncentraty), Napoje bezalkoholowe niegazowane, Napoje bezalkoholowe gazowane, Syropy","methodology":"Zawartość etanolu","parameters":[{"name":"Zakres","range":"(0,010 – 1,0) g/100g"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość etanolu\nZakres (0,010 – 1,0) g/100g\nMetoda spektrofotometryczna","reference":"PB-564 wyd. 1 z dn. 28.10.2024","norm_bases":["PB-564 wyd. 1 z dn. 28.10.2024"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wędliny, Wyroby garmażeryjne, Ocet, Soki owocowe (w tym koncentraty), Napoje bezalkoholowe niegazowane, Napoje bezalkoholowe gazowane, Syropy Zawartość etanolu\nZakres (0,010 – 1,0) g/100g\nMetoda spektrofotometryczna PB-564 wyd. 1 z dn. 28.10.2024 Wedliny, Wyroby garmazeryjne, Ocet, Soki owocowe (w tym koncentraty), Napoje bezalkoholowe niegazowane, Napoje bezalkoholowe gazowane, Syropy Zawartosc etanolu\nZakres (0,010 – 1,0) g/100g\nMetoda spektrofotometryczna PB-564 wyd. 1 z dn. 28.10.2024","categories":["food"],"row_index":313,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Ethanol content","parameters_en":[{"name":"Range","range":"(0,010 – 1,0) g/100g"}],"search_en":"Cured meat products, Delicatessen products, Vinegar, Fruit juices (including concentrates), Still non-alcoholic beverages, Carbonated non-alcoholic beverages, Syrups Ethanol content Spectrophotometric method Classical Analyses Laboratory Range PB-564 wyd. 1 z dn. 28.10.2024","technique_en":"Spectrophotometric method","test_object_en":"Cured meat products, Delicatessen products, Vinegar, Fruit juices (including concentrates), Still non-alcoholic beverages, Carbonated non-alcoholic beverages, Syrups","parameters_zh":[{"name":"范围","range":"(0,010 – 1,0) g/100g"}],"search_zh":"分光光度法 经典分析实验室 范围 PB-564 wyd. 1 z dn. 28.10.2024","technique_zh":"分光光度法","lab_section_zh":"经典分析实验室"},{"_id":"6a7d76396040ebab2620d3b1","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Mleko","methodology":"Zawartość azotynów i azotanów","parameters":[{"name":"azotyny","range":"(0,10 – 40,0) mg/kg"},{"name":"azotany","range":"(1,0 – 40,0) mg/kg"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Zawartość azotynów i azotanów\nZakres:\nazotyny (0,10 – 40,0) mg/kg\nazotany (1,0 – 40,0) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PB-602 wyd. 1 z dn. 23.04.2026","norm_bases":["PB-602 wyd. 1 z dn. 23.04.2026"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko Zawartość azotynów i azotanów\nZakres:\nazotyny (0,10 – 40,0) mg/kg\nazotany (1,0 – 40,0) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PB-602 wyd. 1 z dn. 23.04.2026 Mleko Zawartosc azotynow i azotanow\nZakres:\nazotyny (0,10 – 40,0) mg/kg\nazotany (1,0 – 40,0) mg/kg\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PB-602 wyd. 1 z dn. 23.04.2026","categories":["food"],"row_index":314,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Nitrite and nitrate content","parameters_en":[{"name":"nitrites","range":"(0,10 – 40,0) mg/kg"},{"name":"nitrates","range":"(1,0 – 40,0) mg/kg"}],"search_en":"Milk Nitrite and nitrate content Continuous flow analysis (CFA) with spectrophotometric detection Classical Analyses Laboratory nitrites nitrates PB-602 wyd. 1 z dn. 23.04.2026","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Milk","search_zh":"乳 亚硝酸盐与硝酸盐含量 连续流动分析（CFA）分光光度检测法 经典分析实验室 亚硝酸盐 硝酸盐 PB-602 wyd. 1 z dn. 23.04.2026","technique_zh":"连续流动分析（CFA）分光光度检测法","parameters_zh":[{"name":"亚硝酸盐","range":"(0,10 – 40,0) mg/kg"},{"name":"硝酸盐","range":"(1,0 – 40,0) mg/kg"}],"lab_section_zh":"经典分析实验室","test_object_zh":"乳","methodology_zh":"亚硝酸盐与硝酸盐含量"},{"_id":"6a7d76396040ebab2620d3b2","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Mleko","methodology":"Zawartość soli (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość soli (z obliczeń)","reference":"PB-602 wyd. 1 z dn. 23.04.2026","norm_bases":["PB-602 wyd. 1 z dn. 23.04.2026"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko Zawartość soli (z obliczeń) PB-602 wyd. 1 z dn. 23.04.2026 Mleko Zawartosc soli (z obliczen) PB-602 wyd. 1 z dn. 23.04.2026","categories":["food"],"row_index":315,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Salt content (calculated)","search_en":"Milk Salt content (calculated) Classical Analyses Laboratory PB-602 wyd. 1 z dn. 23.04.2026","test_object_en":"Milk","lab_section_zh":"经典分析实验室","search_zh":"乳 盐含量（由计算得出） 经典分析实验室 PB-602 wyd. 1 z dn. 23.04.2026","test_object_zh":"乳","methodology_zh":"盐含量（由计算得出）"},{"_id":"6a7d76396040ebab2620d3b3","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Produkty mleczne","methodology":"Zawartość azotynów i azotanów","parameters":[{"name":"azotyny","range":"(0,50 – 200) mg/kg"},{"name":"azotany","range":"(5,0 – 200) mg/kg"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Zawartość azotynów i azotanów\nZakres:\nazotyny (0,50 – 200) mg/kg\nazotany (5,0 – 200) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PB-602 wyd. 1 z dn. 23.04.2026","norm_bases":["PB-602 wyd. 1 z dn. 23.04.2026"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Produkty mleczne Zawartość azotynów i azotanów\nZakres:\nazotyny (0,50 – 200) mg/kg\nazotany (5,0 – 200) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PB-602 wyd. 1 z dn. 23.04.2026 Produkty mleczne Zawartosc azotynow i azotanow\nZakres:\nazotyny (0,50 – 200) mg/kg\nazotany (5,0 – 200) mg/kg\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PB-602 wyd. 1 z dn. 23.04.2026","categories":["other"],"row_index":316,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Nitrite and nitrate content","parameters_en":[{"name":"nitrites","range":"(0,50 – 200) mg/kg"},{"name":"nitrates","range":"(5,0 – 200) mg/kg"}],"search_en":"Milk products Nitrite and nitrate content Continuous flow analysis (CFA) with spectrophotometric detection Classical Analyses Laboratory nitrites nitrates PB-602 wyd. 1 z dn. 23.04.2026","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Milk products","search_zh":"乳制品 亚硝酸盐与硝酸盐含量 连续流动分析（CFA）分光光度检测法 经典分析实验室 亚硝酸盐 硝酸盐 PB-602 wyd. 1 z dn. 23.04.2026","technique_zh":"连续流动分析（CFA）分光光度检测法","parameters_zh":[{"name":"亚硝酸盐","range":"(0,50 – 200) mg/kg"},{"name":"硝酸盐","range":"(5,0 – 200) mg/kg"}],"lab_section_zh":"经典分析实验室","methodology_zh":"亚硝酸盐与硝酸盐含量","test_object_zh":"乳制品"},{"_id":"6a7d76396040ebab2620d3b4","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Produkty mleczne","methodology":"Zawartość soli (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość soli (z obliczeń)","reference":"PB-602 wyd. 1 z dn. 23.04.2026","norm_bases":["PB-602 wyd. 1 z dn. 23.04.2026"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Produkty mleczne Zawartość soli (z obliczeń) PB-602 wyd. 1 z dn. 23.04.2026 Produkty mleczne Zawartosc soli (z obliczen) PB-602 wyd. 1 z dn. 23.04.2026","categories":["other"],"row_index":317,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Salt content (calculated)","search_en":"Milk products Salt content (calculated) Classical Analyses Laboratory PB-602 wyd. 1 z dn. 23.04.2026","test_object_en":"Milk products","lab_section_zh":"经典分析实验室","search_zh":"乳制品 盐含量（由计算得出） 经典分析实验室 PB-602 wyd. 1 z dn. 23.04.2026","methodology_zh":"盐含量（由计算得出）","test_object_zh":"乳制品"},{"_id":"6a7d76396040ebab2620d3b5","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość azotynów i azotanów","parameters":[{"name":"azotyny","range":"(1,0 – 250) mg/kg"},{"name":"azotany","range":"(5,0 – 250) mg/kg"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Zawartość azotynów i azotanów\nZakres:\nazotyny (1,0 – 250) mg/kg\nazotany (5,0 – 250) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PB-602 wyd. 1 z dn. 23.04.2026","norm_bases":["PB-602 wyd. 1 z dn. 23.04.2026"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość azotynów i azotanów\nZakres:\nazotyny (1,0 – 250) mg/kg\nazotany (5,0 – 250) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PB-602 wyd. 1 z dn. 23.04.2026 Mieso i przetwory miesne Zawartosc azotynow i azotanow\nZakres:\nazotyny (1,0 – 250) mg/kg\nazotany (5,0 – 250) mg/kg\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PB-602 wyd. 1 z dn. 23.04.2026","categories":["food"],"row_index":318,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Nitrite and nitrate content","parameters_en":[{"name":"nitrites","range":"(1,0 – 250) mg/kg"},{"name":"nitrates","range":"(5,0 – 250) mg/kg"}],"search_en":"Meat and meat products Nitrite and nitrate content Continuous flow analysis (CFA) with spectrophotometric detection Classical Analyses Laboratory nitrites nitrates PB-602 wyd. 1 z dn. 23.04.2026","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Meat and meat products","search_zh":"肉与肉制品 亚硝酸盐与硝酸盐含量 连续流动分析（CFA）分光光度检测法 经典分析实验室 亚硝酸盐 硝酸盐 PB-602 wyd. 1 z dn. 23.04.2026","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"肉与肉制品","parameters_zh":[{"name":"亚硝酸盐","range":"(1,0 – 250) mg/kg"},{"name":"硝酸盐","range":"(5,0 – 250) mg/kg"}],"lab_section_zh":"经典分析实验室","methodology_zh":"亚硝酸盐与硝酸盐含量"},{"_id":"6a7d76396040ebab2620d3b6","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość soli (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość soli (z obliczeń)","reference":"PB-602 wyd. 1 z dn. 23.04.2026","norm_bases":["PB-602 wyd. 1 z dn. 23.04.2026"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość soli (z obliczeń) PB-602 wyd. 1 z dn. 23.04.2026 Mieso i przetwory miesne Zawartosc soli (z obliczen) PB-602 wyd. 1 z dn. 23.04.2026","categories":["food"],"row_index":319,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Salt content (calculated)","search_en":"Meat and meat products Salt content (calculated) Classical Analyses Laboratory PB-602 wyd. 1 z dn. 23.04.2026","test_object_en":"Meat and meat products","search_zh":"肉与肉制品 盐含量（由计算得出） 经典分析实验室 PB-602 wyd. 1 z dn. 23.04.2026","test_object_zh":"肉与肉制品","lab_section_zh":"经典分析实验室","methodology_zh":"盐含量（由计算得出）"},{"_id":"6a7d76396040ebab2620d3b7","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Produkty rolne, Owoce, warzywa i przetwory owocowe i warzywne, Przyprawy","methodology":"Zawartość azotynów i azotanów","parameters":[{"name":"azotyny","range":"(1,0 – 500) mg/kg"},{"name":"azotany","range":"(5,0 – 8000) mg/kg"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Zawartość azotynów i azotanów\nZakres:\nazotyny (1,0 – 500) mg/kg\nazotany (5,0 – 8000) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PB-602 wyd. 1 z dn. 23.04.2026","norm_bases":["PB-602 wyd. 1 z dn. 23.04.2026"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Produkty rolne, Owoce, warzywa i przetwory owocowe i warzywne, Przyprawy Zawartość azotynów i azotanów\nZakres:\nazotyny (1,0 – 500) mg/kg\nazotany (5,0 – 8000) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PB-602 wyd. 1 z dn. 23.04.2026 Produkty rolne, Owoce, warzywa i przetwory owocowe i warzywne, Przyprawy Zawartosc azotynow i azotanow\nZakres:\nazotyny (1,0 – 500) mg/kg\nazotany (5,0 – 8000) mg/kg\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PB-602 wyd. 1 z dn. 23.04.2026","categories":["other"],"row_index":320,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Nitrite and nitrate content","parameters_en":[{"name":"nitrites","range":"(1,0 – 500) mg/kg"},{"name":"nitrates","range":"(5,0 – 8000) mg/kg"}],"search_en":"Agricultural products, Fruit, vegetables and fruit and vegetable products, Spices Nitrite and nitrate content Continuous flow analysis (CFA) with spectrophotometric detection Classical Analyses Laboratory nitrites nitrates PB-602 wyd. 1 z dn. 23.04.2026","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Agricultural products, Fruit, vegetables and fruit and vegetable products, Spices","search_zh":"亚硝酸盐与硝酸盐含量 连续流动分析（CFA）分光光度检测法 经典分析实验室 亚硝酸盐 硝酸盐 PB-602 wyd. 1 z dn. 23.04.2026","technique_zh":"连续流动分析（CFA）分光光度检测法","parameters_zh":[{"name":"亚硝酸盐","range":"(1,0 – 500) mg/kg"},{"name":"硝酸盐","range":"(5,0 – 8000) mg/kg"}],"lab_section_zh":"经典分析实验室","methodology_zh":"亚硝酸盐与硝酸盐含量"},{"_id":"6a7d76396040ebab2620d3b8","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Produkty rolne, Owoce, warzywa i przetwory owocowe i warzywne, Przyprawy","methodology":"Zawartość soli (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość soli (z obliczeń)","reference":"PB-602 wyd. 1 z dn. 23.04.2026","norm_bases":["PB-602 wyd. 1 z dn. 23.04.2026"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Produkty rolne, Owoce, warzywa i przetwory owocowe i warzywne, Przyprawy Zawartość soli (z obliczeń) PB-602 wyd. 1 z dn. 23.04.2026 Produkty rolne, Owoce, warzywa i przetwory owocowe i warzywne, Przyprawy Zawartosc soli (z obliczen) PB-602 wyd. 1 z dn. 23.04.2026","categories":["other"],"row_index":321,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Salt content (calculated)","search_en":"Agricultural products, Fruit, vegetables and fruit and vegetable products, Spices Salt content (calculated) Classical Analyses Laboratory PB-602 wyd. 1 z dn. 23.04.2026","test_object_en":"Agricultural products, Fruit, vegetables and fruit and vegetable products, Spices","lab_section_zh":"经典分析实验室","search_zh":"盐含量（由计算得出） 经典分析实验室 PB-602 wyd. 1 z dn. 23.04.2026","methodology_zh":"盐含量（由计算得出）"},{"_id":"6a7d76396040ebab2620d3b9","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Zboża i przetwory zbożowe, Pasze dla zwierząt","methodology":"Zawartość azotynów i azotanów","parameters":[{"name":"azotyny","range":"(1,0 – 250) mg/kg"},{"name":"azotany","range":"(5,0 – 500) mg/kg"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Zawartość azotynów i azotanów\nZakres:\nazotyny (1,0 – 250) mg/kg\nazotany (5,0 – 500) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PB-602 wyd. 1 z dn. 23.04.2026","norm_bases":["PB-602 wyd. 1 z dn. 23.04.2026"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zboża i przetwory zbożowe, Pasze dla zwierząt Zawartość azotynów i azotanów\nZakres:\nazotyny (1,0 – 250) mg/kg\nazotany (5,0 – 500) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PB-602 wyd. 1 z dn. 23.04.2026 Zboza i przetwory zbozowe, Pasze dla zwierzat Zawartosc azotynow i azotanow\nZakres:\nazotyny (1,0 – 250) mg/kg\nazotany (5,0 – 500) mg/kg\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PB-602 wyd. 1 z dn. 23.04.2026","categories":["food"],"row_index":322,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Nitrite and nitrate content","parameters_en":[{"name":"nitrites","range":"(1,0 – 250) mg/kg"},{"name":"nitrates","range":"(5,0 – 500) mg/kg"}],"search_en":"Cereals and cereal products, Animal feed Nitrite and nitrate content Continuous flow analysis (CFA) with spectrophotometric detection Classical Analyses Laboratory nitrites nitrates PB-602 wyd. 1 z dn. 23.04.2026","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Cereals and cereal products, Animal feed","search_zh":"亚硝酸盐与硝酸盐含量 连续流动分析（CFA）分光光度检测法 经典分析实验室 亚硝酸盐 硝酸盐 PB-602 wyd. 1 z dn. 23.04.2026","technique_zh":"连续流动分析（CFA）分光光度检测法","parameters_zh":[{"name":"亚硝酸盐","range":"(1,0 – 250) mg/kg"},{"name":"硝酸盐","range":"(5,0 – 500) mg/kg"}],"lab_section_zh":"经典分析实验室","methodology_zh":"亚硝酸盐与硝酸盐含量"},{"_id":"6a7d76396040ebab2620d3ba","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Zboża i przetwory zbożowe, Pasze dla zwierząt","methodology":"Zawartość soli (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość soli (z obliczeń)","reference":"PB-602 wyd. 1 z dn. 23.04.2026","norm_bases":["PB-602 wyd. 1 z dn. 23.04.2026"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zboża i przetwory zbożowe, Pasze dla zwierząt Zawartość soli (z obliczeń) PB-602 wyd. 1 z dn. 23.04.2026 Zboza i przetwory zbozowe, Pasze dla zwierzat Zawartosc soli (z obliczen) PB-602 wyd. 1 z dn. 23.04.2026","categories":["food"],"row_index":323,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Salt content (calculated)","search_en":"Cereals and cereal products, Animal feed Salt content (calculated) Classical Analyses Laboratory PB-602 wyd. 1 z dn. 23.04.2026","test_object_en":"Cereals and cereal products, Animal feed","lab_section_zh":"经典分析实验室","search_zh":"盐含量（由计算得出） 经典分析实验室 PB-602 wyd. 1 z dn. 23.04.2026","methodology_zh":"盐含量（由计算得出）"},{"_id":"6a7d76396040ebab2620d3bb","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E","methodology":"pH","parameters":[],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nMetoda potencjometryczna","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E pH\nMetoda potencjometryczna Normy Procedury badawcze Zywnosc E pH\nMetoda potencjometryczna Normy Procedury badawcze","categories":["food"],"row_index":324,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"pH","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E pH Potentiometric method Classical Analyses Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Potentiometric method","test_object_en":"Food E","methodology_zh":"pH 值","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E pH 值 电位法 经典分析实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"电位法","test_object_zh":"食品 E","lab_section_zh":"经典分析实验室"},{"_id":"6a7d76396040ebab2620d3bc","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość azotynów i azotanów","parameters":[],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość azotynów i azotanów\nMetoda spektrofotometryczna","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość azotynów i azotanów\nMetoda spektrofotometryczna Normy Procedury badawcze Zywnosc E Zawartosc azotynow i azotanow\nMetoda spektrofotometryczna Normy Procedury badawcze","categories":["food"],"row_index":325,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Nitrite and nitrate content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E Nitrite and nitrate content Spectrophotometric method Classical Analyses Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Spectrophotometric method","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E 亚硝酸盐与硝酸盐含量 分光光度法 经典分析实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"分光光度法","test_object_zh":"食品 E","lab_section_zh":"经典分析实验室","methodology_zh":"亚硝酸盐与硝酸盐含量"},{"_id":"6a7d76396040ebab2620d3bd","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość skrobi","parameters":[],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość skrobi\nMetoda spektrofotometryczna","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Klasycznych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość skrobi\nMetoda spektrofotometryczna Procedury badawcze Zywnosc E Zawartosc skrobi\nMetoda spektrofotometryczna Procedury badawcze","categories":["food"],"row_index":326,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Classical Analyses Laboratory","methodology_en":"Starch content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E Starch content Spectrophotometric method Classical Analyses Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Procedury badawcze","technique_en":"Spectrophotometric method","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E 淀粉含量 分光光度法 经典分析实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Procedury badawcze","technique_zh":"分光光度法","test_object_zh":"食品 E","lab_section_zh":"经典分析实验室","methodology_zh":"淀粉含量"},{"_id":"6a7d76396040ebab2620d3be","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Koncentraty spożywcze, Chrupki zbożowe","methodology":"Zawartość chlorku sodu","parameters":[{"name":"Zakres","range":"(0,1 – 40,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość chlorku sodu\nZakres (0,1 – 40,0) %\nMetoda miareczkowa","reference":"PN-A-79011-7:1998","norm_bases":["PN-A-79011-7:1998"],"lab_section":"Pracownia Analiz Wartości Odżywczej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Koncentraty spożywcze, Chrupki zbożowe Zawartość chlorku sodu\nZakres (0,1 – 40,0) %\nMetoda miareczkowa PN-A-79011-7:1998 Koncentraty spozywcze, Chrupki zbozowe Zawartosc chlorku sodu\nZakres (0,1 – 40,0) %\nMetoda miareczkowa PN-A-79011-7:1998","categories":["other"],"row_index":327,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Nutritional Value Analyses Laboratory","methodology_en":"Sodium chloride content","parameters_en":[{"name":"Range","range":"(0,1 – 40,0) %"}],"search_en":"Food concentrates, Cereal snacks Sodium chloride content Titrimetric method Nutritional Value Analyses Laboratory Range PN-A-79011-7:1998","technique_en":"Titrimetric method","test_object_en":"Food concentrates, Cereal snacks","parameters_zh":[{"name":"范围","range":"(0,1 – 40,0) %"}],"search_zh":"氯化钠含量 滴定法 营养价值分析实验室 范围 PN-A-79011-7:1998","technique_zh":"滴定法","lab_section_zh":"营养价值分析实验室","methodology_zh":"氯化钠含量"},{"_id":"6a7d76396040ebab2620d3bf","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Produkty mleczne: maślanka w proszku","methodology":"Kwasowość","parameters":[{"name":"Zakres","range":"(0,01 – 0,2) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość\nZakres (0,01 – 0,2) %\nMetoda miareczkowa","reference":"ADPI, Section 1, 2016","norm_bases":["ADPI, Section 1, 2016"],"lab_section":"Pracownia Analiz Wartości Odżywczej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Produkty mleczne: maślanka w proszku Kwasowość\nZakres (0,01 – 0,2) %\nMetoda miareczkowa ADPI, Section 1, 2016 Produkty mleczne: maslanka w proszku Kwasowosc\nZakres (0,01 – 0,2) %\nMetoda miareczkowa ADPI, Section 1, 2016","categories":["other"],"row_index":328,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Nutritional Value Analyses Laboratory","methodology_en":"Acidity","parameters_en":[{"name":"Range","range":"(0,01 – 0,2) %"}],"search_en":"Dairy products: buttermilk powder Acidity Titrimetric method Nutritional Value Analyses Laboratory Range ADPI, Section 1, 2016","technique_en":"Titrimetric method","test_object_en":"Dairy products: buttermilk powder","methodology_zh":"酸度","parameters_zh":[{"name":"范围","range":"(0,01 – 0,2) %"}],"search_zh":"酸度 滴定法 营养价值分析实验室 范围 ADPI, Section 1, 2016","technique_zh":"滴定法","lab_section_zh":"营养价值分析实验室"},{"_id":"6a7d76396040ebab2620d3c0","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Mleko w proszku","methodology":"Kwasowość","parameters":[{"name":"Zakres","range":"(0,08 – 0,2) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość\nZakres (0,08 – 0,2) %\nMetoda miareczkowa","reference":"ADPI, Section 1, 2016","norm_bases":["ADPI, Section 1, 2016"],"lab_section":"Pracownia Analiz Wartości Odżywczej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko w proszku Kwasowość\nZakres (0,08 – 0,2) %\nMetoda miareczkowa ADPI, Section 1, 2016 Mleko w proszku Kwasowosc\nZakres (0,08 – 0,2) %\nMetoda miareczkowa ADPI, Section 1, 2016","categories":["food"],"row_index":329,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Nutritional Value Analyses Laboratory","methodology_en":"Acidity","parameters_en":[{"name":"Range","range":"(0,08 – 0,2) %"}],"search_en":"Milk powder Acidity Titrimetric method Nutritional Value Analyses Laboratory Range ADPI, Section 1, 2016","technique_en":"Titrimetric method","test_object_en":"Milk powder","methodology_zh":"酸度","parameters_zh":[{"name":"范围","range":"(0,08 – 0,2) %"}],"search_zh":"乳粉 酸度 滴定法 营养价值分析实验室 范围 ADPI, Section 1, 2016","technique_zh":"滴定法","lab_section_zh":"营养价值分析实验室","test_object_zh":"乳粉"},{"_id":"6a7d76396040ebab2620d3c1","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Mleko w proszku","methodology":"Kwasowość","parameters":[{"name":"od 8,0 ml 0,1 mol/l NaOH/10 g s.m.b. do 20 ml 0,1 mol/l NaOH/10 g s.m.b."}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość\nod 8,0 ml 0,1 mol/l NaOH/10 g s.m.b. do 20 ml 0,1 mol/l NaOH/10 g s.m.b.\nMetoda miareczkowa","reference":"PN-ISO 6091:2012","norm_bases":["PN-ISO 6091:2012"],"lab_section":"Pracownia Analiz Wartości Odżywczej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko w proszku Kwasowość\nod 8,0 ml 0,1 mol/l NaOH/10 g s.m.b. do 20 ml 0,1 mol/l NaOH/10 g s.m.b.\nMetoda miareczkowa PN-ISO 6091:2012 Mleko w proszku Kwasowosc\nod 8,0 ml 0,1 mol/l NaOH/10 g s.m.b. do 20 ml 0,1 mol/l NaOH/10 g s.m.b.\nMetoda miareczkowa PN-ISO 6091:2012","categories":["food"],"row_index":330,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Nutritional Value Analyses Laboratory","methodology_en":"Acidity","parameters_en":[{"name":"from 8,0 ml 0,1 mol/l NaOH/10 g f.f.d.m. to 20 ml 0,1 mol/l NaOH/10 g f.f.d.m."}],"search_en":"Milk powder Acidity Titrimetric method Nutritional Value Analyses Laboratory from 8,0 ml 0,1 mol/l NaOH/10 g f.f.d.m. to 20 ml 0,1 mol/l NaOH/10 g f.f.d.m. PN-ISO 6091:2012","technique_en":"Titrimetric method","test_object_en":"Milk powder","methodology_zh":"酸度","search_zh":"乳粉 酸度 滴定法 营养价值分析实验室 PN-ISO 6091:2012","technique_zh":"滴定法","lab_section_zh":"营养价值分析实验室","test_object_zh":"乳粉"},{"_id":"6a7d76396040ebab2620d3c2","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Owoce i warzywa, Przetwory owocowo-warzywne","methodology":"Kwasowość ogólna w przeliczeniu na odpowiedni kwas","parameters":[{"name":"Zakres","range":"(0,1 – 2,5) % (m/m)"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość ogólna w przeliczeniu na odpowiedni kwas\nZakres (0,1 – 2,5) % (m/m)\nMetoda miareczkowa","reference":"PN-90/A-75101/04+Az1:2002","norm_bases":["PN-90/A-75101/04+Az1:2002"],"lab_section":"Pracownia Analiz Wartości Odżywczej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Owoce i warzywa, Przetwory owocowo-warzywne Kwasowość ogólna w przeliczeniu na odpowiedni kwas\nZakres (0,1 – 2,5) % (m/m)\nMetoda miareczkowa PN-90/A-75101/04+Az1:2002 Owoce i warzywa, Przetwory owocowo-warzywne Kwasowosc ogolna w przeliczeniu na odpowiedni kwas\nZakres (0,1 – 2,5) % (m/m)\nMetoda miareczkowa PN-90/A-75101/04+Az1:2002","categories":["other"],"row_index":331,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Nutritional Value Analyses Laboratory","methodology_en":"Total acidity expressed as the relevant acid","parameters_en":[{"name":"Range","range":"(0,1 – 2,5) % (m/m)"}],"search_en":"Fruit and vegetables, Fruit-vegetable products Total acidity expressed as the relevant acid Titrimetric method Nutritional Value Analyses Laboratory Range PN-90/A-75101/04+Az1:2002","technique_en":"Titrimetric method","test_object_en":"Fruit and vegetables, Fruit-vegetable products","parameters_zh":[{"name":"范围","range":"(0,1 – 2,5) % (m/m)"}],"search_zh":"以相应酸计的总酸度 滴定法 营养价值分析实验室 范围 PN-90/A-75101/04+Az1:2002","technique_zh":"滴定法","lab_section_zh":"营养价值分析实验室","methodology_zh":"以相应酸计的总酸度"},{"_id":"6a7d76396040ebab2620d3c3","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Mięso i produkty mięsne","methodology":"Zawartość mięsa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość mięsa (z obliczeń)","reference":"PB-282 wyd. 3 z dn. 21.01.2025","norm_bases":["PB-282 wyd. 3 z dn. 21.01.2025"],"lab_section":"Pracownia Analiz Wartości Odżywczej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i produkty mięsne Zawartość mięsa (z obliczeń) PB-282 wyd. 3 z dn. 21.01.2025 Mieso i produkty miesne Zawartosc miesa (z obliczen) PB-282 wyd. 3 z dn. 21.01.2025","categories":["food"],"row_index":332,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Nutritional Value Analyses Laboratory","methodology_en":"Meat content (calculated)","search_en":"Meat and meat products Meat content (calculated) Nutritional Value Analyses Laboratory PB-282 wyd. 3 z dn. 21.01.2025","test_object_en":"Meat and meat products","search_zh":"肉与肉制品 肉含量（由计算得出） 营养价值分析实验室 PB-282 wyd. 3 z dn. 21.01.2025","test_object_zh":"肉与肉制品","lab_section_zh":"营养价值分析实验室","methodology_zh":"肉含量（由计算得出）"},{"_id":"6a7d76396040ebab2620d3c4","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Mięso i produkty mięsne","methodology":"Zawartość soli kuchennej","parameters":[{"name":"Zakres","range":"(0,10 – 10,00) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość soli kuchennej\nZakres (0,10 – 10,00) %\nMetoda miareczkowa","reference":"PN-73/A-82112+Az1:2002","norm_bases":["PN-73/A-82112+Az1:2002"],"lab_section":"Pracownia Analiz Wartości Odżywczej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i produkty mięsne Zawartość soli kuchennej\nZakres (0,10 – 10,00) %\nMetoda miareczkowa PN-73/A-82112+Az1:2002 Mieso i produkty miesne Zawartosc soli kuchennej\nZakres (0,10 – 10,00) %\nMetoda miareczkowa PN-73/A-82112+Az1:2002","categories":["food"],"row_index":333,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Nutritional Value Analyses Laboratory","methodology_en":"Table salt content","parameters_en":[{"name":"Range","range":"(0,10 – 10,00) %"}],"search_en":"Meat and meat products Table salt content Titrimetric method Nutritional Value Analyses Laboratory Range PN-73/A-82112+Az1:2002","technique_en":"Titrimetric method","test_object_en":"Meat and meat products","parameters_zh":[{"name":"范围","range":"(0,10 – 10,00) %"}],"search_zh":"肉与肉制品 食盐含量 滴定法 营养价值分析实验室 范围 PN-73/A-82112+Az1:2002","technique_zh":"滴定法","test_object_zh":"肉与肉制品","lab_section_zh":"营养价值分析实验室","methodology_zh":"食盐含量"},{"_id":"6a7d76396040ebab2620d3c5","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Ryby i przetwory rybne","methodology":"Zawartość soli kuchennej","parameters":[{"name":"Zakres","range":"(0,1 – 8,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość soli kuchennej\nZakres (0,1 – 8,0) %\nMetoda miareczkowa","reference":"PN-74/A-86739 | PN-85/A-82100","norm_bases":["PN-74/A-86739","PN-85/A-82100"],"lab_section":"Pracownia Analiz Wartości Odżywczej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ryby i przetwory rybne Zawartość soli kuchennej\nZakres (0,1 – 8,0) %\nMetoda miareczkowa PN-74/A-86739 | PN-85/A-82100 Ryby i przetwory rybne Zawartosc soli kuchennej\nZakres (0,1 – 8,0) %\nMetoda miareczkowa PN-74/A-86739 | PN-85/A-82100","categories":["other"],"row_index":334,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Nutritional Value Analyses Laboratory","methodology_en":"Table salt content","parameters_en":[{"name":"Range","range":"(0,1 – 8,0) %"}],"search_en":"Fish and fish products Table salt content Titrimetric method Nutritional Value Analyses Laboratory Range PN-74/A-86739 | PN-85/A-82100","technique_en":"Titrimetric method","test_object_en":"Fish and fish products","parameters_zh":[{"name":"范围","range":"(0,1 – 8,0) %"}],"search_zh":"鱼与鱼制品 食盐含量 滴定法 营养价值分析实验室 范围 PN-74/A-86739 | PN-85/A-82100","technique_zh":"滴定法","test_object_zh":"鱼与鱼制品","lab_section_zh":"营养价值分析实验室","methodology_zh":"食盐含量"},{"_id":"6a7d76396040ebab2620d3c6","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Ryby i przetwory rybne","methodology":"Kwasowość ogólna","parameters":[{"name":"Zakres","range":"(0,5 – 4,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość ogólna\nZakres (0,5 – 4,0) %\nMetoda miareczkowa","reference":"PN-74/A-86746 | PN-85/A-82100","norm_bases":["PN-74/A-86746","PN-85/A-82100"],"lab_section":"Pracownia Analiz Wartości Odżywczej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ryby i przetwory rybne Kwasowość ogólna\nZakres (0,5 – 4,0) %\nMetoda miareczkowa PN-74/A-86746 | PN-85/A-82100 Ryby i przetwory rybne Kwasowosc ogolna\nZakres (0,5 – 4,0) %\nMetoda miareczkowa PN-74/A-86746 | PN-85/A-82100","categories":["other"],"row_index":335,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Nutritional Value Analyses Laboratory","methodology_en":"Total acidity","parameters_en":[{"name":"Range","range":"(0,5 – 4,0) %"}],"search_en":"Fish and fish products Total acidity Titrimetric method Nutritional Value Analyses Laboratory Range PN-74/A-86746 | PN-85/A-82100","technique_en":"Titrimetric method","test_object_en":"Fish and fish products","parameters_zh":[{"name":"范围","range":"(0,5 – 4,0) %"}],"search_zh":"鱼与鱼制品 总酸度 滴定法 营养价值分析实验室 范围 PN-74/A-86746 | PN-85/A-82100","technique_zh":"滴定法","test_object_zh":"鱼与鱼制品","lab_section_zh":"营养价值分析实验室","methodology_zh":"总酸度"},{"_id":"6a7d76396040ebab2620d3c7","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Produkty mleczne: serwatka w proszku","methodology":"Kwasowość","parameters":[{"name":"Zakres","range":"(0,05 – 2,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość\nZakres (0,05 – 2,0) %\nMetoda miareczkowa","reference":"PB-25 wyd. III z dn. 04.02.2009","norm_bases":["PB-25 wyd. III z dn. 04.02.2009"],"lab_section":"Pracownia Analiz Wartości Odżywczej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Produkty mleczne: serwatka w proszku Kwasowość\nZakres (0,05 – 2,0) %\nMetoda miareczkowa PB-25 wyd. III z dn. 04.02.2009 Produkty mleczne: serwatka w proszku Kwasowosc\nZakres (0,05 – 2,0) %\nMetoda miareczkowa PB-25 wyd. III z dn. 04.02.2009","categories":["other"],"row_index":336,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Nutritional Value Analyses Laboratory","methodology_en":"Acidity","parameters_en":[{"name":"Range","range":"(0,05 – 2,0) %"}],"search_en":"Milk products: whey powder Acidity Titrimetric method Nutritional Value Analyses Laboratory Range PB-25 wyd. III z dn. 04.02.2009","technique_en":"Titrimetric method","test_object_en":"Milk products: whey powder","methodology_zh":"酸度","parameters_zh":[{"name":"范围","range":"(0,05 – 2,0) %"}],"search_zh":"乳制品：乳清粉 酸度 滴定法 营养价值分析实验室 范围 PB-25 wyd. III z dn. 04.02.2009","technique_zh":"滴定法","lab_section_zh":"营养价值分析实验室","test_object_zh":"乳制品：乳清粉"},{"_id":"6a7d76396040ebab2620d3c8","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Produkty mleczne: sery","methodology":"Zawartość chlorków","parameters":[{"name":"Zakres","range":"(0,20 – 6,00) %"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Zawartość chlorków\nZakres (0,20 – 6,00) %\nMetoda potencjometryczna","reference":"PN-EN ISO 5943:2007 | ISO 5943:2006 IDF-FIL 88:2006","norm_bases":["PN-EN ISO 5943:2007","ISO 5943:2006 IDF-FIL 88:2006"],"lab_section":"Pracownia Analiz Wartości Odżywczej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Produkty mleczne: sery Zawartość chlorków\nZakres (0,20 – 6,00) %\nMetoda potencjometryczna PN-EN ISO 5943:2007 | ISO 5943:2006 IDF-FIL 88:2006 Produkty mleczne: sery Zawartosc chlorkow\nZakres (0,20 – 6,00) %\nMetoda potencjometryczna PN-EN ISO 5943:2007 | ISO 5943:2006 IDF-FIL 88:2006","categories":["other"],"row_index":337,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Nutritional Value Analyses Laboratory","methodology_en":"Chloride content","parameters_en":[{"name":"Range","range":"(0,20 – 6,00) %"}],"search_en":"Milk products: cheeses Chloride content Potentiometric method Nutritional Value Analyses Laboratory Range PN-EN ISO 5943:2007 | ISO 5943:2006 IDF-FIL 88:2006","technique_en":"Potentiometric method","test_object_en":"Milk products: cheeses","parameters_zh":[{"name":"范围","range":"(0,20 – 6,00) %"}],"search_zh":"氯化物含量 电位法 营养价值分析实验室 范围 PN-EN ISO 5943:2007 | ISO 5943:2006 IDF-FIL 88:2006","technique_zh":"电位法","methodology_zh":"氯化物含量","lab_section_zh":"营养价值分析实验室"},{"_id":"6a7d76396040ebab2620d3c9","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Produkty mleczne: śmietanka i śmietana","methodology":"Kwasowość","parameters":[{"name":"Zakres","range":"(0,2 – 30,0) 0SH"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość\nZakres (0,2 – 30,0) 0SH\nMetoda miareczkowa","reference":"PN-78/A-86028+Az2:2002","norm_bases":["PN-78/A-86028+Az2:2002"],"lab_section":"Pracownia Analiz Wartości Odżywczej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Produkty mleczne: śmietanka i śmietana Kwasowość\nZakres (0,2 – 30,0) 0SH\nMetoda miareczkowa PN-78/A-86028+Az2:2002 Produkty mleczne: smietanka i smietana Kwasowosc\nZakres (0,2 – 30,0) 0SH\nMetoda miareczkowa PN-78/A-86028+Az2:2002","categories":["other"],"row_index":338,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Nutritional Value Analyses Laboratory","methodology_en":"Acidity","parameters_en":[{"name":"Range","range":"(0,2 – 30,0) 0SH"}],"search_en":"Milk products: sweet cream and sour cream Acidity Titrimetric method Nutritional Value Analyses Laboratory Range PN-78/A-86028+Az2:2002","technique_en":"Titrimetric method","test_object_en":"Milk products: sweet cream and sour cream","methodology_zh":"酸度","parameters_zh":[{"name":"范围","range":"(0,2 – 30,0) 0SH"}],"search_zh":"酸度 滴定法 营养价值分析实验室 范围 PN-78/A-86028+Az2:2002","technique_zh":"滴定法","lab_section_zh":"营养价值分析实验室"},{"_id":"6a7d76396040ebab2620d3ca","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Wyroby garmażeryjne, Wyroby kulinarne mrożone","methodology":"Zawartość chlorku sodu","parameters":[{"name":"Zakres","range":"(0,5 – 5,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość chlorku sodu\nZakres (0,5 – 5,0) %\nMetoda miareczkowa","reference":"PN-85/A-82100","norm_bases":["PN-85/A-82100"],"lab_section":"Pracownia Analiz Wartości Odżywczej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby garmażeryjne, Wyroby kulinarne mrożone Zawartość chlorku sodu\nZakres (0,5 – 5,0) %\nMetoda miareczkowa PN-85/A-82100 Wyroby garmazeryjne, Wyroby kulinarne mrozone Zawartosc chlorku sodu\nZakres (0,5 – 5,0) %\nMetoda miareczkowa PN-85/A-82100","categories":["other"],"row_index":339,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Nutritional Value Analyses Laboratory","methodology_en":"Sodium chloride content","parameters_en":[{"name":"Range","range":"(0,5 – 5,0) %"}],"search_en":"Delicatessen products, Frozen culinary products Sodium chloride content Titrimetric method Nutritional Value Analyses Laboratory Range PN-85/A-82100","technique_en":"Titrimetric method","test_object_en":"Delicatessen products, Frozen culinary products","parameters_zh":[{"name":"范围","range":"(0,5 – 5,0) %"}],"search_zh":"氯化钠含量 滴定法 营养价值分析实验室 范围 PN-85/A-82100","technique_zh":"滴定法","lab_section_zh":"营养价值分析实验室","methodology_zh":"氯化钠含量"},{"_id":"6a7d76396040ebab2620d3cb","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E","methodology":"Zawartość tłuszczu","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość tłuszczu\nMetoda wagowa","reference":"Normy Procedury badawcze Przepisy prawa","norm_bases":["Normy Procedury badawcze Przepisy prawa"],"lab_section":"Pracownia Analiz Wartości Odżywczej","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E Zawartość tłuszczu\nMetoda wagowa Normy Procedury badawcze Przepisy prawa Zywnosc E, Pasze dla zwierzat E Zawartosc tluszczu\nMetoda wagowa Normy Procedury badawcze Przepisy prawa","categories":["food"],"row_index":340,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Nutritional Value Analyses Laboratory","methodology_en":"Fat content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E Fat content Gravimetric method Nutritional Value Analyses Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze Przepisy prawa","technique_en":"Gravimetric method","test_object_en":"Food E, Animal feed E","methodology_zh":"脂肪含量","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E 脂肪含量 重量法 营养价值分析实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze Przepisy prawa","technique_zh":"重量法","lab_section_zh":"营养价值分析实验室","test_object_zh":"食品 E、动物饲料 E"},{"_id":"6a7d76396040ebab2620d3cc","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E","methodology":"Zawartość azotu Kjeldahla, Zawartość białka","parameters":[],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu Kjeldahla, Zawartość białka\nMetoda miareczkowa","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Analiz Wartości Odżywczej","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E Zawartość azotu Kjeldahla, Zawartość białka\nMetoda miareczkowa Normy Procedury badawcze Zywnosc E, Pasze dla zwierzat E Zawartosc azotu Kjeldahla, Zawartosc bialka\nMetoda miareczkowa Normy Procedury badawcze","categories":["food"],"row_index":341,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Nutritional Value Analyses Laboratory","methodology_en":"Kjeldahl nitrogen content, Protein content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E Kjeldahl nitrogen content, Protein content Titrimetric method Nutritional Value Analyses Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Titrimetric method","test_object_en":"Food E, Animal feed E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E 滴定法 营养价值分析实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"滴定法","lab_section_zh":"营养价值分析实验室","test_object_zh":"食品 E、动物饲料 E"},{"_id":"6a7d76396040ebab2620d3cd","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Pasze dla zwierząt E","methodology":"Zawartość błonnika pokarmowego","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość błonnika pokarmowego\nMetoda wagowa","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Analiz Wartości Odżywczej","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze dla zwierząt E Zawartość błonnika pokarmowego\nMetoda wagowa Normy Procedury badawcze Zywnosc E, Pasze dla zwierzat E Zawartosc blonnika pokarmowego\nMetoda wagowa Normy Procedury badawcze","categories":["food"],"row_index":342,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Nutritional Value Analyses Laboratory","methodology_en":"Dietary fibre content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Animal feed E Dietary fibre content Gravimetric method Nutritional Value Analyses Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Gravimetric method","test_object_en":"Food E, Animal feed E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、动物饲料 E 膳食纤维含量 重量法 营养价值分析实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"重量法","lab_section_zh":"营养价值分析实验室","methodology_zh":"膳食纤维含量","test_object_zh":"食品 E、动物饲料 E"},{"_id":"6a7d76396040ebab2620d3ce","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E","methodology":"Wartość energetyczna, Zawartość węglowodanów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość energetyczna, Zawartość węglowodanów (z obliczeń)","reference":"Przepisy prawa","norm_bases":["Przepisy prawa"],"lab_section":"Pracownia Analiz Wartości Odżywczej","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Wartość energetyczna, Zawartość węglowodanów (z obliczeń) Przepisy prawa Zywnosc E Wartosc energetyczna, Zawartosc weglowodanow (z obliczen) Przepisy prawa","categories":["food"],"row_index":343,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Nutritional Value Analyses Laboratory","methodology_en":"Energy value, Carbohydrate content (calculated)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E Energy value, Carbohydrate content (calculated) Nutritional Value Analyses Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Przepisy prawa","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E 营养价值分析实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Przepisy prawa","test_object_zh":"食品 E","lab_section_zh":"营养价值分析实验室"},{"_id":"6a7d76396040ebab2620d3cf","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Produkty rolne E, Pasze dla zwierząt E, Żywność E","methodology":"Zawartość cholesterolu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość cholesterolu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Analiz Wartości Odżywczej","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Produkty rolne E, Pasze dla zwierząt E, Żywność E Zawartość cholesterolu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy Procedury badawcze Produkty rolne E, Pasze dla zwierzat E, Zywnosc E Zawartosc cholesterolu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy Procedury badawcze","categories":["food"],"row_index":344,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Nutritional Value Analyses Laboratory","methodology_en":"Cholesterol content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Agricultural products E, Animal feed E, Food E Cholesterol content Gas chromatography with flame ionization detection (GC-FID) Nutritional Value Analyses Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Agricultural products E, Animal feed E, Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"胆固醇含量 气相色谱-氢火焰离子化检测法（GC-FID） 营养价值分析实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"营养价值分析实验室","methodology_zh":"胆固醇含量"},{"_id":"6a7d76396040ebab2620d3d0","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Produkty rolne E, Pasze dla zwierząt E, Żywność E","methodology":"Zawartość kwasów tłuszczowych","parameters":[{"name":"Suma (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość kwasów tłuszczowych\nSuma (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Analiz Wartości Odżywczej","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Produkty rolne E, Pasze dla zwierząt E, Żywność E Zawartość kwasów tłuszczowych\nSuma (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy Procedury badawcze Produkty rolne E, Pasze dla zwierzat E, Zywnosc E Zawartosc kwasow tluszczowych\nSuma (z obliczen)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy Procedury badawcze","categories":["food"],"row_index":345,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Nutritional Value Analyses Laboratory","methodology_en":"Fatty acid content","parameters_en":[{"name":"Sum (calculated)"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Agricultural products E, Animal feed E, Food E Fatty acid content Gas chromatography with flame ionization detection (GC-FID) Nutritional Value Analyses Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Sum (calculated) Normy Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Agricultural products E, Animal feed E, Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"脂肪酸含量 气相色谱-氢火焰离子化检测法（GC-FID） 营养价值分析实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 总量（由计算得出） Normy Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"营养价值分析实验室","parameters_zh":[{"name":"总量（由计算得出）"}],"methodology_zh":"脂肪酸含量"},{"_id":"6a7d76396040ebab2620d3d1","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość alkoholi wielowodorotlenowych","parameters":[],"technique":"Metoda wysokosprawnej chromatografii anionowymiennej z detekcją pulsowej amperometrii (HPIC-PAD)","techniques":["Metoda wysokosprawnej chromatografii anionowymiennej z detekcją pulsowej amperometrii (HPIC-PAD)"],"computed":[],"activity":"Zawartość alkoholi wielowodorotlenowych\nMetoda wysokosprawnej chromatografii anionowymiennej z detekcją pulsowej amperometrii (HPIC-PAD)","reference":"PB-429","norm_bases":["PB-429"],"lab_section":"Pracownia Analiz Wartości Odżywczej","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość alkoholi wielowodorotlenowych\nMetoda wysokosprawnej chromatografii anionowymiennej z detekcją pulsowej amperometrii (HPIC-PAD) PB-429 Zywnosc E Zawartosc alkoholi wielowodorotlenowych\nMetoda wysokosprawnej chromatografii anionowymiennej z detekcja pulsowej amperometrii (HPIC-PAD) PB-429","categories":["food"],"row_index":346,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Nutritional Value Analyses Laboratory","methodology_en":"Polyhydric alcohol content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E Polyhydric alcohol content High-performance anion-exchange chromatography with pulsed amperometric detection (HPIC-PAD) Nutritional Value Analyses Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. PB-429","technique_en":"High-performance anion-exchange chromatography with pulsed amperometric detection (HPIC-PAD)","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E 营养价值分析实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 PB-429","test_object_zh":"食品 E","lab_section_zh":"营养价值分析实验室"},{"_id":"6a7d76396040ebab2620d3d2","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Obiekty z obszaru produkcji żywności E, Pasze dla zwierząt E","methodology":"Zawartość cukrów","parameters":[],"technique":"Metoda wysokosprawnej chromatografii anionowymiennej z detekcją pulsowej amperometrii (HPIC-PAD)","techniques":["Metoda wysokosprawnej chromatografii anionowymiennej z detekcją pulsowej amperometrii (HPIC-PAD)"],"computed":[],"activity":"Zawartość cukrów\nMetoda wysokosprawnej chromatografii anionowymiennej z detekcją pulsowej amperometrii (HPIC-PAD)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Wartości Odżywczej","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Obiekty z obszaru produkcji żywności E, Pasze dla zwierząt E Zawartość cukrów\nMetoda wysokosprawnej chromatografii anionowymiennej z detekcją pulsowej amperometrii (HPIC-PAD) Procedury badawcze Zywnosc E, Obiekty z obszaru produkcji zywnosci E, Pasze dla zwierzat E Zawartosc cukrow\nMetoda wysokosprawnej chromatografii anionowymiennej z detekcja pulsowej amperometrii (HPIC-PAD) Procedury badawcze","categories":["food"],"row_index":347,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Nutritional Value Analyses Laboratory","methodology_en":"Sugar content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Objects from the food production area E, Animal feed E Sugar content High-performance anion-exchange chromatography with pulsed amperometric detection (HPIC-PAD) Nutritional Value Analyses Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Procedury badawcze","technique_en":"High-performance anion-exchange chromatography with pulsed amperometric detection (HPIC-PAD)","test_object_en":"Food E, Objects from the food production area E, Animal feed E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"糖含量 营养价值分析实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Procedury badawcze","methodology_zh":"糖含量","lab_section_zh":"营养价值分析实验室"},{"_id":"6a7d76396040ebab2620d3d3","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Produkty rolne E, Pasze dla zwierząt E","methodology":"Zawartość wody i substancji lotnych (sucha masa)","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wody i substancji lotnych (sucha masa)\nMetoda wagowa","reference":"Normy Procedury badawcze Przepisy prawa","norm_bases":["Normy Procedury badawcze Przepisy prawa"],"lab_section":"Pracownia Analiz Wartości Odżywczej","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Produkty rolne E, Pasze dla zwierząt E Zawartość wody i substancji lotnych (sucha masa)\nMetoda wagowa Normy Procedury badawcze Przepisy prawa Zywnosc E, Produkty rolne E, Pasze dla zwierzat E Zawartosc wody i substancji lotnych (sucha masa)\nMetoda wagowa Normy Procedury badawcze Przepisy prawa","categories":["food","water"],"row_index":348,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Nutritional Value Analyses Laboratory","methodology_en":"Content of water and volatile substances (dry matter)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Agricultural products E, Animal feed E Content of water and volatile substances (dry matter) Gravimetric method Nutritional Value Analyses Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze Przepisy prawa","technique_en":"Gravimetric method","test_object_en":"Food E, Agricultural products E, Animal feed E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、农产品 E、动物饲料 E 重量法 营养价值分析实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze Przepisy prawa","technique_zh":"重量法","lab_section_zh":"营养价值分析实验室","test_object_zh":"食品 E、农产品 E、动物饲料 E"},{"_id":"6a7d76396040ebab2620d3d4","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Produkty rolne E, Pasze dla zwierząt E","methodology":"Zawartość popiołu","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu\nMetoda wagowa","reference":"Normy Procedury badawcze Przepisy prawa","norm_bases":["Normy Procedury badawcze Przepisy prawa"],"lab_section":"Pracownia Analiz Wartości Odżywczej","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Produkty rolne E, Pasze dla zwierząt E Zawartość popiołu\nMetoda wagowa Normy Procedury badawcze Przepisy prawa Zywnosc E, Produkty rolne E, Pasze dla zwierzat E Zawartosc popiolu\nMetoda wagowa Normy Procedury badawcze Przepisy prawa","categories":["food"],"row_index":349,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Nutritional Value Analyses Laboratory","methodology_en":"Ash content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Agricultural products E, Animal feed E Ash content Gravimetric method Nutritional Value Analyses Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze Przepisy prawa","technique_en":"Gravimetric method","test_object_en":"Food E, Agricultural products E, Animal feed E","methodology_zh":"灰分含量","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、农产品 E、动物饲料 E 灰分含量 重量法 营养价值分析实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze Przepisy prawa","technique_zh":"重量法","lab_section_zh":"营养价值分析实验室","test_object_zh":"食品 E、农产品 E、动物饲料 E"},{"_id":"6a7d76396040ebab2620d3d5","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Wyroby chemii gospodarczej: płyny i żele, proszki, pasty, mydła w płynie, szampony","methodology":"Sucha pozostałość","parameters":[{"name":"Zakres","range":"(0,10 – 60,0) % (m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość\nZakres (0,10 – 60,0) % (m/m)\nMetoda wagowa","reference":"PB-107 wyd. I z dn. 01.09.2010","norm_bases":["PB-107 wyd. I z dn. 01.09.2010"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemii gospodarczej: płyny i żele, proszki, pasty, mydła w płynie, szampony Sucha pozostałość\nZakres (0,10 – 60,0) % (m/m)\nMetoda wagowa PB-107 wyd. I z dn. 01.09.2010 Wyroby chemii gospodarczej: plyny i zele, proszki, pasty, mydla w plynie, szampony Sucha pozostalosc\nZakres (0,10 – 60,0) % (m/m)\nMetoda wagowa PB-107 wyd. I z dn. 01.09.2010","categories":["other"],"row_index":350,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Dry residue","parameters_en":[{"name":"Range","range":"(0,10 – 60,0) % (m/m)"}],"search_en":"Household chemical products: liquids and gels, powders, pastes, liquid soaps, shampoos Dry residue Gravimetric method Non-Food Products and Packaging Testing Laboratory Range PB-107 wyd. I z dn. 01.09.2010","technique_en":"Gravimetric method","test_object_en":"Household chemical products: liquids and gels, powders, pastes, liquid soaps, shampoos","lab_section_zh":"非食品产品与包装检测实验室","parameters_zh":[{"name":"范围","range":"(0,10 – 60,0) % (m/m)"}],"search_zh":"家用化学制品：液体与凝胶、粉剂、膏剂、液体皂、洗发剂 干残渣 重量法 非食品产品与包装检测实验室 范围 PB-107 wyd. I z dn. 01.09.2010","technique_zh":"重量法","methodology_zh":"干残渣","test_object_zh":"家用化学制品：液体与凝胶、粉剂、膏剂、液体皂、洗发剂"},{"_id":"6a7d76396040ebab2620d3d6","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Wyroby chemii gospodarczej: płyny i żele, proszki, pasty, mydła w płynie, szampony","methodology":"Sucha pozostałość organiczna","parameters":[{"name":"Zakres","range":"(0,10 – 60,0) % (m/m)"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Sucha pozostałość organiczna\nZakres:\nZakres (0,10 – 60,0) % (m/m)\n(z obliczeń)","reference":"PB-107 wyd. I z dn. 01.09.2010","norm_bases":["PB-107 wyd. I z dn. 01.09.2010"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemii gospodarczej: płyny i żele, proszki, pasty, mydła w płynie, szampony Sucha pozostałość organiczna\nZakres:\nZakres (0,10 – 60,0) % (m/m)\n(z obliczeń) PB-107 wyd. I z dn. 01.09.2010 Wyroby chemii gospodarczej: plyny i zele, proszki, pasty, mydla w plynie, szampony Sucha pozostalosc organiczna\nZakres:\nZakres (0,10 – 60,0) % (m/m)\n(z obliczen) PB-107 wyd. I z dn. 01.09.2010","categories":["other"],"row_index":351,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Organic dry residue","parameters_en":[{"name":"Range","range":"(0,10 – 60,0) % (m/m)"},{"name":"(calculated)"}],"search_en":"Household chemical products: liquids and gels, powders, pastes, liquid soaps, shampoos Organic dry residue Non-Food Products and Packaging Testing Laboratory Range (calculated) PB-107 wyd. I z dn. 01.09.2010","test_object_en":"Household chemical products: liquids and gels, powders, pastes, liquid soaps, shampoos","lab_section_zh":"非食品产品与包装检测实验室","parameters_zh":[{"name":"范围","range":"(0,10 – 60,0) % (m/m)"},{"name":"（计算得出）"}],"search_zh":"家用化学制品：液体与凝胶、粉剂、膏剂、液体皂、洗发剂 非食品产品与包装检测实验室 范围 （计算得出） PB-107 wyd. I z dn. 01.09.2010","test_object_zh":"家用化学制品：液体与凝胶、粉剂、膏剂、液体皂、洗发剂"},{"_id":"6a7d76396040ebab2620d3d7","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Wyroby chemii gospodarczej: płyny i żele, proszki, pasty, mydła w płynie, szampony","methodology":"Zawartość chlorków w przeliczeniu na NaCl","parameters":[{"name":"Zakres","range":"(0,1 – 10,0) % (m/m)"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość chlorków w przeliczeniu na NaCl\nZakres (0,1 – 10,0) % (m/m)\nMetoda miareczkowa","reference":"PB-108 wyd. I z dn. 01.09.2010","norm_bases":["PB-108 wyd. I z dn. 01.09.2010"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemii gospodarczej: płyny i żele, proszki, pasty, mydła w płynie, szampony Zawartość chlorków w przeliczeniu na NaCl\nZakres (0,1 – 10,0) % (m/m)\nMetoda miareczkowa PB-108 wyd. I z dn. 01.09.2010 Wyroby chemii gospodarczej: plyny i zele, proszki, pasty, mydla w plynie, szampony Zawartosc chlorkow w przeliczeniu na NaCl\nZakres (0,1 – 10,0) % (m/m)\nMetoda miareczkowa PB-108 wyd. I z dn. 01.09.2010","categories":["other"],"row_index":352,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Chloride content expressed as NaCl","parameters_en":[{"name":"Range","range":"(0,1 – 10,0) % (m/m)"}],"search_en":"Household chemical products: liquids and gels, powders, pastes, liquid soaps, shampoos Chloride content expressed as NaCl Titrimetric method Non-Food Products and Packaging Testing Laboratory Range PB-108 wyd. I z dn. 01.09.2010","technique_en":"Titrimetric method","test_object_en":"Household chemical products: liquids and gels, powders, pastes, liquid soaps, shampoos","lab_section_zh":"非食品产品与包装检测实验室","parameters_zh":[{"name":"范围","range":"(0,1 – 10,0) % (m/m)"}],"search_zh":"家用化学制品：液体与凝胶、粉剂、膏剂、液体皂、洗发剂 氯化物含量（以 NaCl 计） 滴定法 非食品产品与包装检测实验室 范围 PB-108 wyd. I z dn. 01.09.2010","technique_zh":"滴定法","methodology_zh":"氯化物含量（以 NaCl 计）","test_object_zh":"家用化学制品：液体与凝胶、粉剂、膏剂、液体皂、洗发剂"},{"_id":"6a7d76396040ebab2620d3d8","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Wyroby chemii gospodarczej: płyny i żele, proszki, pasty, mydła w płynie, szampony","methodology":"pH","parameters":[{"name":"Zakres","range":"1,0 – 12,0"},{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna pH 1 % roztworu wodnego; Metoda potencjometryczna","techniques":["Metoda potencjometryczna pH 1 % roztworu wodnego","Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres:\nZakres 1,0 – 12,0\nZakres 2,0 – 12,0\nMetoda potencjometryczna pH 1 % roztworu wodnego; Metoda potencjometryczna","reference":"PB-109 wyd. I z dn. 01.09.2010","norm_bases":["PB-109 wyd. I z dn. 01.09.2010"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemii gospodarczej: płyny i żele, proszki, pasty, mydła w płynie, szampony pH\nZakres:\nZakres 1,0 – 12,0\nZakres 2,0 – 12,0\nMetoda potencjometryczna pH 1 % roztworu wodnego; Metoda potencjometryczna PB-109 wyd. I z dn. 01.09.2010 Wyroby chemii gospodarczej: plyny i zele, proszki, pasty, mydla w plynie, szampony pH\nZakres:\nZakres 1,0 – 12,0\nZakres 2,0 – 12,0\nMetoda potencjometryczna pH 1 % roztworu wodnego; Metoda potencjometryczna PB-109 wyd. I z dn. 01.09.2010","categories":["other"],"row_index":353,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"1,0 – 12,0"},{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Household chemical products: liquids and gels, powders, pastes, liquid soaps, shampoos pH Potentiometric method pH of a 1 % aqueous solution; Potentiometric method Non-Food Products and Packaging Testing Laboratory Range Range PB-109 wyd. I z dn. 01.09.2010","technique_en":"Potentiometric method pH of a 1 % aqueous solution; Potentiometric method","test_object_en":"Household chemical products: liquids and gels, powders, pastes, liquid soaps, shampoos","lab_section_zh":"非食品产品与包装检测实验室","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"1,0 – 12,0"},{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"家用化学制品：液体与凝胶、粉剂、膏剂、液体皂、洗发剂 pH 值 非食品产品与包装检测实验室 范围 范围 PB-109 wyd. I z dn. 01.09.2010","test_object_zh":"家用化学制品：液体与凝胶、粉剂、膏剂、液体皂、洗发剂"},{"_id":"6a7d76396040ebab2620d3d9","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Wyroby chemii gospodarczej i kosmetyki: - płyny i żele, proszki, pasty, mydła w płynie, szampony","methodology":"Zawartość substancji anionowo czynnych","parameters":[{"name":"Zakres","range":"(0,50 – 30,00) % (m/m)"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość substancji anionowo czynnych\nZakres (0,50 – 30,00) % (m/m)\nMetoda miareczkowa","reference":"PN-ISO 2271:2000","norm_bases":["PN-ISO 2271:2000"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemii gospodarczej i kosmetyki: - płyny i żele, proszki, pasty, mydła w płynie, szampony Zawartość substancji anionowo czynnych\nZakres (0,50 – 30,00) % (m/m)\nMetoda miareczkowa PN-ISO 2271:2000 Wyroby chemii gospodarczej i kosmetyki: - plyny i zele, proszki, pasty, mydla w plynie, szampony Zawartosc substancji anionowo czynnych\nZakres (0,50 – 30,00) % (m/m)\nMetoda miareczkowa PN-ISO 2271:2000","categories":["pharma"],"row_index":354,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Content of anionic surfactants","parameters_en":[{"name":"Range","range":"(0,50 – 30,00) % (m/m)"}],"search_en":"Household chemical products and cosmetics: - liquids and gels, powders, pastes, liquid soaps, shampoos Content of anionic surfactants Titrimetric method Non-Food Products and Packaging Testing Laboratory Range PN-ISO 2271:2000","technique_en":"Titrimetric method","test_object_en":"Household chemical products and cosmetics: - liquids and gels, powders, pastes, liquid soaps, shampoos","lab_section_zh":"非食品产品与包装检测实验室","parameters_zh":[{"name":"范围","range":"(0,50 – 30,00) % (m/m)"}],"search_zh":"滴定法 非食品产品与包装检测实验室 范围 PN-ISO 2271:2000","technique_zh":"滴定法"},{"_id":"6a7d76396040ebab2620d3da","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Wyroby chemii gospodarczej i kosmetyki: - płyny i żele, mydła w płynie, szampony","methodology":"Gęstość","parameters":[{"name":"Zakres","range":"(0,850 – 1,350) g/cm3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość\nZakres (0,850 – 1,350) g/cm3\nMetoda oscylacyjna","reference":"PB-489 wyd. I z dn. 15.10.2021","norm_bases":["PB-489 wyd. I z dn. 15.10.2021"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemii gospodarczej i kosmetyki: - płyny i żele, mydła w płynie, szampony Gęstość\nZakres (0,850 – 1,350) g/cm3\nMetoda oscylacyjna PB-489 wyd. I z dn. 15.10.2021 Wyroby chemii gospodarczej i kosmetyki: - plyny i zele, mydla w plynie, szampony Gestosc\nZakres (0,850 – 1,350) g/cm3\nMetoda oscylacyjna PB-489 wyd. I z dn. 15.10.2021","categories":["pharma"],"row_index":355,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Density","parameters_en":[{"name":"Range","range":"(0,850 – 1,350) g/cm3"}],"search_en":"Household chemical products and cosmetics: - liquids and gels, liquid soaps, shampoos Density Oscillation method Non-Food Products and Packaging Testing Laboratory Range PB-489 wyd. I z dn. 15.10.2021","technique_en":"Oscillation method","test_object_en":"Household chemical products and cosmetics: - liquids and gels, liquid soaps, shampoos","lab_section_zh":"非食品产品与包装检测实验室","methodology_zh":"密度","parameters_zh":[{"name":"范围","range":"(0,850 – 1,350) g/cm3"}],"search_zh":"密度 振荡法 非食品产品与包装检测实验室 范围 PB-489 wyd. I z dn. 15.10.2021","technique_zh":"振荡法"},{"_id":"6a7d76396040ebab2620d3db","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z papieru, tektury, Materiały i wyroby z tworzyw sztucznych","methodology":"Trwałość wybarwienia","parameters":[{"name":"Zakres","range":"1 – 5"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Trwałość wybarwienia\nZakres 1 – 5\nMetoda wizualna","reference":"PN-EN 648:2019-03","norm_bases":["PN-EN 648:2019-03"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z papieru, tektury, Materiały i wyroby z tworzyw sztucznych Trwałość wybarwienia\nZakres 1 – 5\nMetoda wizualna PN-EN 648:2019-03 Materialy i wyroby z papieru, tektury, Materialy i wyroby z tworzyw sztucznych Trwalosc wybarwienia\nZakres 1 – 5\nMetoda wizualna PN-EN 648:2019-03","categories":["materials"],"row_index":356,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Colour fastness","parameters_en":[{"name":"Range","range":"1 – 5"}],"search_en":"Paper and board materials and articles, Plastic materials and articles Colour fastness Visual method Non-Food Products and Packaging Testing Laboratory Range PN-EN 648:2019-03","technique_en":"Visual method","test_object_en":"Paper and board materials and articles, Plastic materials and articles","lab_section_zh":"非食品产品与包装检测实验室","parameters_zh":[{"name":"范围","range":"1 – 5"}],"search_zh":"目视法 非食品产品与包装检测实验室 范围 PN-EN 648:2019-03","technique_zh":"目视法"},{"_id":"6a7d76396040ebab2620d3dc","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z papieru, tektury","methodology":"Gramatura","parameters":[{"name":"Zakres","range":"(25,0 – 1000) g/m2"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Gramatura\nZakres (25,0 – 1000) g/m2\nMetoda wagowa","reference":"PN-EN ISO 536:2020-08","norm_bases":["PN-EN ISO 536:2020-08"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z papieru, tektury Gramatura\nZakres (25,0 – 1000) g/m2\nMetoda wagowa PN-EN ISO 536:2020-08 Materialy i wyroby z papieru, tektury Gramatura\nZakres (25,0 – 1000) g/m2\nMetoda wagowa PN-EN ISO 536:2020-08","categories":["materials"],"row_index":357,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Grammage","parameters_en":[{"name":"Range","range":"(25,0 – 1000) g/m2"}],"search_en":"Materials and articles of paper and paperboard Grammage Gravimetric method Non-Food Products and Packaging Testing Laboratory Range PN-EN ISO 536:2020-08","technique_en":"Gravimetric method","test_object_en":"Materials and articles of paper and paperboard","lab_section_zh":"非食品产品与包装检测实验室","parameters_zh":[{"name":"范围","range":"(25,0 – 1000) g/m2"}],"search_zh":"纸与纸板材料及制品 面密度 重量法 非食品产品与包装检测实验室 范围 PN-EN ISO 536:2020-08","technique_zh":"重量法","methodology_zh":"面密度","test_object_zh":"纸与纸板材料及制品"},{"_id":"6a7d76396040ebab2620d3dd","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z papieru, tektury","methodology":"Zawartość wilgoci","parameters":[{"name":"Zakres","range":"(0,05 – 60,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci\nZakres (0,05 – 60,0) %\nMetoda wagowa","reference":"PN-EN ISO 287:2018-02","norm_bases":["PN-EN ISO 287:2018-02"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z papieru, tektury Zawartość wilgoci\nZakres (0,05 – 60,0) %\nMetoda wagowa PN-EN ISO 287:2018-02 Materialy i wyroby z papieru, tektury Zawartosc wilgoci\nZakres (0,05 – 60,0) %\nMetoda wagowa PN-EN ISO 287:2018-02","categories":["materials"],"row_index":358,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Moisture content","parameters_en":[{"name":"Range","range":"(0,05 – 60,0) %"}],"search_en":"Materials and articles of paper and paperboard Moisture content Gravimetric method Non-Food Products and Packaging Testing Laboratory Range PN-EN ISO 287:2018-02","technique_en":"Gravimetric method","test_object_en":"Materials and articles of paper and paperboard","lab_section_zh":"非食品产品与包装检测实验室","parameters_zh":[{"name":"范围","range":"(0,05 – 60,0) %"}],"search_zh":"纸与纸板材料及制品 水分含量 重量法 非食品产品与包装检测实验室 范围 PN-EN ISO 287:2018-02","technique_zh":"重量法","methodology_zh":"水分含量","test_object_zh":"纸与纸板材料及制品"},{"_id":"6a7d76396040ebab2620d3de","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z papieru, tektury","methodology":"Trwałość wybarwienia","parameters":[{"name":"Zakres","range":"1 – 5"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Trwałość wybarwienia\nZakres 1 – 5\nMetoda wizualna","reference":"PN-EN 646:2019-03","norm_bases":["PN-EN 646:2019-03"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z papieru, tektury Trwałość wybarwienia\nZakres 1 – 5\nMetoda wizualna PN-EN 646:2019-03 Materialy i wyroby z papieru, tektury Trwalosc wybarwienia\nZakres 1 – 5\nMetoda wizualna PN-EN 646:2019-03","categories":["materials"],"row_index":359,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Colour fastness","parameters_en":[{"name":"Range","range":"1 – 5"}],"search_en":"Materials and articles of paper and paperboard Colour fastness Visual method Non-Food Products and Packaging Testing Laboratory Range PN-EN 646:2019-03","technique_en":"Visual method","test_object_en":"Materials and articles of paper and paperboard","lab_section_zh":"非食品产品与包装检测实验室","parameters_zh":[{"name":"范围","range":"1 – 5"}],"search_zh":"纸与纸板材料及制品 目视法 非食品产品与包装检测实验室 范围 PN-EN 646:2019-03","technique_zh":"目视法","test_object_zh":"纸与纸板材料及制品"},{"_id":"6a7d76396040ebab2620d3df","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z papieru, tektury","methodology":"Zawartość benzofenonu, 4-metylobenzofenonu, 2-hydroksybenzofenonu, 4-hydroksybenzofenonu","parameters":[{"name":"Zakres","range":"(0,02 – 10) mg/dm2"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość benzofenonu, 4-metylobenzofenonu, 2-hydroksybenzofenonu, 4-hydroksybenzofenonu\nZakres (0,02 – 10) mg/dm2\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"P B - 2 4 7 / G C wyd. I z dn. 03.02.2014","norm_bases":["P B - 2 4 7 / G C wyd. I z dn. 03.02.2014"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z papieru, tektury Zawartość benzofenonu, 4-metylobenzofenonu, 2-hydroksybenzofenonu, 4-hydroksybenzofenonu\nZakres (0,02 – 10) mg/dm2\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) P B - 2 4 7 / G C wyd. I z dn. 03.02.2014 Materialy i wyroby z papieru, tektury Zawartosc benzofenonu, 4-metylobenzofenonu, 2-hydroksybenzofenonu, 4-hydroksybenzofenonu\nZakres (0,02 – 10) mg/dm2\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) P B - 2 4 7 / G C wyd. I z dn. 03.02.2014","categories":["materials"],"row_index":360,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Benzophenone, 4-methylbenzophenone, 2-hydroxybenzophenone, 4-hydroxybenzophenone content","parameters_en":[{"name":"Range","range":"(0,02 – 10) mg/dm2"}],"search_en":"Materials and articles of paper and paperboard Benzophenone, 4-methylbenzophenone, 2-hydroxybenzophenone, 4-hydroxybenzophenone content Gas chromatography with mass spectrometry detection (GC-MS) Non-Food Products and Packaging Testing Laboratory Range P B - 2 4 7 / G C wyd. I z dn. 03.02.2014","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Materials and articles of paper and paperboard","lab_section_zh":"非食品产品与包装检测实验室","parameters_zh":[{"name":"范围","range":"(0,02 – 10) mg/dm2"}],"search_zh":"纸与纸板材料及制品 气相色谱-质谱法（GC-MS） 非食品产品与包装检测实验室 范围 P B - 2 4 7 / G C wyd. I z dn. 03.02.2014","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"纸与纸板材料及制品"},{"_id":"6a7d76396040ebab2620d3e0","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z papieru, tektury","methodology":"Zawartość 4,4’-bis(dimetyloamino)benzofenonu i 4,4’-bis(dietyloamino)benzofenonu","parameters":[{"name":"Zakres","range":"(0,0016 – 0,0048) mg/dm2"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość 4,4’-bis(dimetyloamino)benzofenonu i 4,4’-bis(dietyloamino)benzofenonu\nZakres (0,0016 – 0,0048) mg/dm2\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PB-252/GC wyd. I z dn. 0 3 . 02.2014","norm_bases":["PB-252/GC wyd. I z dn. 0 3 . 02.2014"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z papieru, tektury Zawartość 4,4’-bis(dimetyloamino)benzofenonu i 4,4’-bis(dietyloamino)benzofenonu\nZakres (0,0016 – 0,0048) mg/dm2\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PB-252/GC wyd. I z dn. 0 3 . 02.2014 Materialy i wyroby z papieru, tektury Zawartosc 4,4’-bis(dimetyloamino)benzofenonu i 4,4’-bis(dietyloamino)benzofenonu\nZakres (0,0016 – 0,0048) mg/dm2\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PB-252/GC wyd. I z dn. 0 3 . 02.2014","categories":["materials"],"row_index":361,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"4,4’-bis(dimethylamino)benzophenone and 4,4’-bis(diethylamino)benzophenone content","parameters_en":[{"name":"Range","range":"(0,0016 – 0,0048) mg/dm2"}],"search_en":"Materials and articles of paper and paperboard 4,4’-bis(dimethylamino)benzophenone and 4,4’-bis(diethylamino)benzophenone content Gas chromatography with mass spectrometry detection (GC-MS) Non-Food Products and Packaging Testing Laboratory Range PB-252/GC wyd. I z dn. 0 3 . 02.2014","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Materials and articles of paper and paperboard","lab_section_zh":"非食品产品与包装检测实验室","parameters_zh":[{"name":"范围","range":"(0,0016 – 0,0048) mg/dm2"}],"search_zh":"纸与纸板材料及制品 气相色谱-质谱法（GC-MS） 非食品产品与包装检测实验室 范围 PB-252/GC wyd. I z dn. 0 3 . 02.2014","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"纸与纸板材料及制品"},{"_id":"6a7d76396040ebab2620d3e1","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z papieru i tektury oraz ich wyciągi wodne","methodology":"Zawartość formaldehydu","parameters":[{"name":"Zakres","range":"(1,0 – 30) mg/kg"},{"name":"Zakres","range":"(0,0010 – 3,0) mg/dm2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość formaldehydu\nZakres:\nZakres (1,0 – 30) mg/kg\nZakres (0,0010 – 3,0) mg/dm2\nMetoda spektrofotometryczna","reference":"PN-EN 1541:2003","norm_bases":["PN-EN 1541:2003"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z papieru i tektury oraz ich wyciągi wodne Zawartość formaldehydu\nZakres:\nZakres (1,0 – 30) mg/kg\nZakres (0,0010 – 3,0) mg/dm2\nMetoda spektrofotometryczna PN-EN 1541:2003 Materialy i wyroby z papieru i tektury oraz ich wyciagi wodne Zawartosc formaldehydu\nZakres:\nZakres (1,0 – 30) mg/kg\nZakres (0,0010 – 3,0) mg/dm2\nMetoda spektrofotometryczna PN-EN 1541:2003","categories":["materials"],"row_index":362,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Formaldehyde content","parameters_en":[{"name":"Range","range":"(1,0 – 30) mg/kg"},{"name":"Range","range":"(0,0010 – 3,0) mg/dm2"}],"search_en":"Paper and board materials and articles and their water extracts Formaldehyde content Spectrophotometric method Non-Food Products and Packaging Testing Laboratory Range Range PN-EN 1541:2003","technique_en":"Spectrophotometric method","test_object_en":"Paper and board materials and articles and their water extracts","lab_section_zh":"非食品产品与包装检测实验室","parameters_zh":[{"name":"范围","range":"(1,0 – 30) mg/kg"},{"name":"范围","range":"(0,0010 – 3,0) mg/dm2"}],"search_zh":"甲醛含量 分光光度法 非食品产品与包装检测实验室 范围 范围 PN-EN 1541:2003","technique_zh":"分光光度法","methodology_zh":"甲醛含量"},{"_id":"6a7d76396040ebab2620d3e2","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z papieru, masy włóknistej, tektury","methodology":"Zawartość diizopropylonaftalenu","parameters":[{"name":"Zakres","range":"(0,6 – 10) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość diizopropylonaftalenu\nZakres (0,6 – 10) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PN-EN 14719: 2006","norm_bases":["PN-EN 14719: 2006"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z papieru, masy włóknistej, tektury Zawartość diizopropylonaftalenu\nZakres (0,6 – 10) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PN-EN 14719: 2006 Materialy i wyroby z papieru, masy wloknistej, tektury Zawartosc diizopropylonaftalenu\nZakres (0,6 – 10) mg/kg\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PN-EN 14719: 2006","categories":["materials"],"row_index":363,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Diisopropylnaphthalene content","parameters_en":[{"name":"Range","range":"(0,6 – 10) mg/kg"}],"search_en":"Materials and articles made of paper, pulp, board Diisopropylnaphthalene content Gas chromatography with mass spectrometry detection (GC-MS) Non-Food Products and Packaging Testing Laboratory Range PN-EN 14719: 2006","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Materials and articles made of paper, pulp, board","lab_section_zh":"非食品产品与包装检测实验室","parameters_zh":[{"name":"范围","range":"(0,6 – 10) mg/kg"}],"search_zh":"气相色谱-质谱法（GC-MS） 非食品产品与包装检测实验室 范围 PN-EN 14719: 2006","technique_zh":"气相色谱-质谱法（GC-MS）"},{"_id":"6a7d76396040ebab2620d3e3","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z papieru, masy włóknistej, tektury oraz ich wyciągi wodne","methodology":"Zawartość pentachlorofenolu","parameters":[{"name":"Zakres","range":"(0,05 – 0,5) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość pentachlorofenolu\nZakres (0,05 – 0,5) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PN-EN ISO 15320: 2011","norm_bases":["PN-EN ISO 15320: 2011"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z papieru, masy włóknistej, tektury oraz ich wyciągi wodne Zawartość pentachlorofenolu\nZakres (0,05 – 0,5) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PN-EN ISO 15320: 2011 Materialy i wyroby z papieru, masy wloknistej, tektury oraz ich wyciagi wodne Zawartosc pentachlorofenolu\nZakres (0,05 – 0,5) mg/kg\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PN-EN ISO 15320: 2011","categories":["materials"],"row_index":364,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Pentachlorophenol content","parameters_en":[{"name":"Range","range":"(0,05 – 0,5) mg/kg"}],"search_en":"Materials and articles made of paper, pulp, board and their water extracts Pentachlorophenol content Gas chromatography with mass spectrometry detection (GC-MS) Non-Food Products and Packaging Testing Laboratory Range PN-EN ISO 15320: 2011","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Materials and articles made of paper, pulp, board and their water extracts","lab_section_zh":"非食品产品与包装检测实验室","parameters_zh":[{"name":"范围","range":"(0,05 – 0,5) mg/kg"}],"search_zh":"五氯苯酚含量 气相色谱-质谱法（GC-MS） 非食品产品与包装检测实验室 范围 PN-EN ISO 15320: 2011","technique_zh":"气相色谱-质谱法（GC-MS）","methodology_zh":"五氯苯酚含量"},{"_id":"6a7d76396040ebab2620d3e4","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Bibułki tissue i wyroby z bibułki tissue","methodology":"Gramatura","parameters":[{"name":"Zakres","range":"(15,0 – 85,0) g/m2"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Gramatura\nZakres (15,0 – 85,0) g/m2\nMetoda wagowa","reference":"PN-EN ISO 12625-6:2017-03","norm_bases":["PN-EN ISO 12625-6:2017-03"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Bibułki tissue i wyroby z bibułki tissue Gramatura\nZakres (15,0 – 85,0) g/m2\nMetoda wagowa PN-EN ISO 12625-6:2017-03 Bibulki tissue i wyroby z bibulki tissue Gramatura\nZakres (15,0 – 85,0) g/m2\nMetoda wagowa PN-EN ISO 12625-6:2017-03","categories":["other"],"row_index":365,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Grammage","parameters_en":[{"name":"Range","range":"(15,0 – 85,0) g/m2"}],"search_en":"Tissue paper and tissue paper products Grammage Gravimetric method Non-Food Products and Packaging Testing Laboratory Range PN-EN ISO 12625-6:2017-03","technique_en":"Gravimetric method","test_object_en":"Tissue paper and tissue paper products","lab_section_zh":"非食品产品与包装检测实验室","parameters_zh":[{"name":"范围","range":"(15,0 – 85,0) g/m2"}],"search_zh":"面密度 重量法 非食品产品与包装检测实验室 范围 PN-EN ISO 12625-6:2017-03","technique_zh":"重量法","methodology_zh":"面密度"},{"_id":"6a7d76396040ebab2620d3e5","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji","methodology":"Zawartość formaldehydu","parameters":[{"name":"Zakres","range":"(1,5 – 30) mg/kg płynu"},{"name":"modelowego"}],"technique":"Metoda spektrofotometryczna z 2,4–pentanodionem","techniques":["Metoda spektrofotometryczna z 2,4–pentanodionem"],"computed":[],"activity":"Zawartość formaldehydu\nZakres:\nZakres (1,5 – 30) mg/kg płynu\nmodelowego\nMetoda spektrofotometryczna z 2,4–pentanodionem","reference":"CEN/TS 13130-23:2005","norm_bases":["CEN/TS 13130-23:2005"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji Zawartość formaldehydu\nZakres:\nZakres (1,5 – 30) mg/kg płynu\nmodelowego\nMetoda spektrofotometryczna z 2,4–pentanodionem CEN/TS 13130-23:2005 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia, Plyny modelowe po migracji Zawartosc formaldehydu\nZakres:\nZakres (1,5 – 30) mg/kg plynu\nmodelowego\nMetoda spektrofotometryczna z 2,4–pentanodionem CEN/TS 13130-23:2005","categories":["materials","food"],"row_index":366,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Formaldehyde content","parameters_en":[{"name":"Range","range":"(1,5 – 30) mg/kg płynu"},{"name":"simulant"}],"search_en":"Plastic materials and articles intended to come into contact with food, Food simulants after migration Formaldehyde content Spectrophotometric method with 2,4–pentanedione Non-Food Products and Packaging Testing Laboratory Range simulant CEN/TS 13130-23:2005","technique_en":"Spectrophotometric method with 2,4–pentanedione","test_object_en":"Plastic materials and articles intended to come into contact with food, Food simulants after migration","lab_section_zh":"非食品产品与包装检测实验室","parameters_zh":[{"name":"范围","range":"(1,5 – 30) mg/kg płynu"},{"name":"模拟物的"}],"search_zh":"拟与食品接触的塑料材料与制品、迁移试验后的食品模拟物 甲醛含量 非食品产品与包装检测实验室 范围 模拟物的 CEN/TS 13130-23:2005","methodology_zh":"甲醛含量","test_object_zh":"拟与食品接触的塑料材料与制品、迁移试验后的食品模拟物"},{"_id":"6a7d76396040ebab2620d3e6","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji","methodology":"Migracja specyficzna formaldehydu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Migracja specyficzna formaldehydu (z obliczeń)","reference":"CEN/TS 13130-23:2005","norm_bases":["CEN/TS 13130-23:2005"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji Migracja specyficzna formaldehydu (z obliczeń) CEN/TS 13130-23:2005 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia, Plyny modelowe po migracji Migracja specyficzna formaldehydu (z obliczen) CEN/TS 13130-23:2005","categories":["materials","food"],"row_index":367,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Specific migration of formaldehyde (calculated)","search_en":"Plastic materials and articles intended to come into contact with food, Food simulants after migration Specific migration of formaldehyde (calculated) Non-Food Products and Packaging Testing Laboratory CEN/TS 13130-23:2005","test_object_en":"Plastic materials and articles intended to come into contact with food, Food simulants after migration","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"拟与食品接触的塑料材料与制品、迁移试验后的食品模拟物 非食品产品与包装检测实验室 CEN/TS 13130-23:2005","test_object_zh":"拟与食品接触的塑料材料与制品、迁移试验后的食品模拟物"},{"_id":"6a7d76396040ebab2620d3e7","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji","methodology":"Zawartość octanu winylu","parameters":[{"name":"Zakres","range":"(1,2 – 24,0) mg/kg płynu"},{"name":"modelowego"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)"],"computed":[],"activity":"Zawartość octanu winylu\nZakres:\nZakres (1,2 – 24,0) mg/kg płynu\nmodelowego\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","reference":"CEN/TS 13130-9:2005","norm_bases":["CEN/TS 13130-9:2005"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji Zawartość octanu winylu\nZakres:\nZakres (1,2 – 24,0) mg/kg płynu\nmodelowego\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID) CEN/TS 13130-9:2005 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia, Plyny modelowe po migracji Zawartosc octanu winylu\nZakres:\nZakres (1,2 – 24,0) mg/kg plynu\nmodelowego\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja plomieniowo-jonizacyjna (HS-GC-FID) CEN/TS 13130-9:2005","categories":["materials","food"],"row_index":368,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Vinyl acetate content","parameters_en":[{"name":"Range","range":"(1,2 – 24,0) mg/kg płynu"},{"name":"simulant"}],"search_en":"Plastic materials and articles intended to come into contact with food, Food simulants after migration Vinyl acetate content Headspace gas chromatography with flame ionization detection (HS-GC-FID) Non-Food Products and Packaging Testing Laboratory Range simulant CEN/TS 13130-9:2005","technique_en":"Headspace gas chromatography with flame ionization detection (HS-GC-FID)","test_object_en":"Plastic materials and articles intended to come into contact with food, Food simulants after migration","lab_section_zh":"非食品产品与包装检测实验室","parameters_zh":[{"name":"范围","range":"(1,2 – 24,0) mg/kg płynu"},{"name":"模拟物的"}],"search_zh":"拟与食品接触的塑料材料与制品、迁移试验后的食品模拟物 乙酸乙烯酯含量 顶空气相色谱-火焰离子化检测法（HS-GC-FID） 非食品产品与包装检测实验室 范围 模拟物的 CEN/TS 13130-9:2005","technique_zh":"顶空气相色谱-火焰离子化检测法（HS-GC-FID）","test_object_zh":"拟与食品接触的塑料材料与制品、迁移试验后的食品模拟物","methodology_zh":"乙酸乙烯酯含量"},{"_id":"6a7d76396040ebab2620d3e8","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji","methodology":"Migracja specyficzna octanu winylu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Migracja specyficzna octanu winylu (z obliczeń)","reference":"CEN/TS 13130-9:2005","norm_bases":["CEN/TS 13130-9:2005"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji Migracja specyficzna octanu winylu (z obliczeń) CEN/TS 13130-9:2005 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia, Plyny modelowe po migracji Migracja specyficzna octanu winylu (z obliczen) CEN/TS 13130-9:2005","categories":["materials","food"],"row_index":369,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Specific migration of vinyl acetate (calculated)","search_en":"Plastic materials and articles intended to come into contact with food, Food simulants after migration Specific migration of vinyl acetate (calculated) Non-Food Products and Packaging Testing Laboratory CEN/TS 13130-9:2005","test_object_en":"Plastic materials and articles intended to come into contact with food, Food simulants after migration","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"拟与食品接触的塑料材料与制品、迁移试验后的食品模拟物 非食品产品与包装检测实验室 CEN/TS 13130-9:2005","test_object_zh":"拟与食品接触的塑料材料与制品、迁移试验后的食品模拟物"},{"_id":"6a7d76396040ebab2620d3e9","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji","methodology":"Zawartość bezwodnika maleinowego (w przeliczeniu na kwas maleinowy)","parameters":[{"name":"Zakres","range":"(3,0 – 60,0) mg/kg płynu"},{"name":"modelowego"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/Vis)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/Vis)"],"computed":[],"activity":"Zawartość bezwodnika maleinowego (w przeliczeniu na kwas maleinowy)\nZakres:\nZakres (3,0 – 60,0) mg/kg płynu\nmodelowego\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/Vis)","reference":"CEN/TS 13130-24:2005","norm_bases":["CEN/TS 13130-24:2005"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji Zawartość bezwodnika maleinowego (w przeliczeniu na kwas maleinowy)\nZakres:\nZakres (3,0 – 60,0) mg/kg płynu\nmodelowego\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/Vis) CEN/TS 13130-24:2005 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia, Plyny modelowe po migracji Zawartosc bezwodnika maleinowego (w przeliczeniu na kwas maleinowy)\nZakres:\nZakres (3,0 – 60,0) mg/kg plynu\nmodelowego\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV/Vis) CEN/TS 13130-24:2005","categories":["materials","food"],"row_index":370,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Maleic anhydride content (calculated as maleic acid)","parameters_en":[{"name":"Range","range":"(3,0 – 60,0) mg/kg płynu"},{"name":"simulant"}],"search_en":"Plastic materials and articles intended to come into contact with food, Food simulants after migration Maleic anhydride content (calculated as maleic acid) High-performance liquid chromatography with spectrophotometric detection (HPLC-UV/Vis) Non-Food Products and Packaging Testing Laboratory Range simulant CEN/TS 13130-24:2005","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV/Vis)","test_object_en":"Plastic materials and articles intended to come into contact with food, Food simulants after migration","lab_section_zh":"非食品产品与包装检测实验室","parameters_zh":[{"name":"范围","range":"(3,0 – 60,0) mg/kg płynu"},{"name":"模拟物的"}],"search_zh":"拟与食品接触的塑料材料与制品、迁移试验后的食品模拟物 高效液相色谱-分光光度检测法（HPLC-UV/Vis） 非食品产品与包装检测实验室 范围 模拟物的 CEN/TS 13130-24:2005","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV/Vis）","test_object_zh":"拟与食品接触的塑料材料与制品、迁移试验后的食品模拟物"},{"_id":"6a7d76396040ebab2620d3ea","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji","methodology":"Migracja specyficzna bezwodnika maleinowego (w przeliczeniu na kwas maleinowy) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Migracja specyficzna bezwodnika maleinowego (w przeliczeniu na kwas maleinowy) (z obliczeń)","reference":"CEN/TS 13130-24:2005","norm_bases":["CEN/TS 13130-24:2005"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji Migracja specyficzna bezwodnika maleinowego (w przeliczeniu na kwas maleinowy) (z obliczeń) CEN/TS 13130-24:2005 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia, Plyny modelowe po migracji Migracja specyficzna bezwodnika maleinowego (w przeliczeniu na kwas maleinowy) (z obliczen) CEN/TS 13130-24:2005","categories":["materials","food"],"row_index":371,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Specific migration of maleic anhydride (expressed as maleic acid) (calculated)","search_en":"Plastic materials and articles intended to come into contact with food, Food simulants after migration Specific migration of maleic anhydride (expressed as maleic acid) (calculated) Non-Food Products and Packaging Testing Laboratory CEN/TS 13130-24:2005","test_object_en":"Plastic materials and articles intended to come into contact with food, Food simulants after migration","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"拟与食品接触的塑料材料与制品、迁移试验后的食品模拟物 非食品产品与包装检测实验室 CEN/TS 13130-24:2005","test_object_zh":"拟与食品接触的塑料材料与制品、迁移试验后的食品模拟物"},{"_id":"6a7d76396040ebab2620d3eb","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Materiały i wyroby z gumy przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji","methodology":"Zawartość N,N-bis(2-hydroksyetylo)alkilo(C8-C18)aminy","parameters":[{"name":"Zakres","range":"(0,4 – 5) mg/kg płynu modelowego"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (HPLC-MS-MS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (HPLC-MS-MS)"],"computed":[],"activity":"Zawartość N,N-bis(2-hydroksyetylo)alkilo(C8-C18)aminy\nZakres (0,4 – 5) mg/kg płynu modelowego\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (HPLC-MS-MS)","reference":"PB-341/LC wyd. I z dn. 12.09.2016","norm_bases":["PB-341/LC wyd. I z dn. 12.09.2016"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Materiały i wyroby z gumy przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji Zawartość N,N-bis(2-hydroksyetylo)alkilo(C8-C18)aminy\nZakres (0,4 – 5) mg/kg płynu modelowego\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (HPLC-MS-MS) PB-341/LC wyd. I z dn. 12.09.2016 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia, Materialy i wyroby z gumy przeznaczone do kontaktu z zywnoscia, Plyny modelowe po migracji Zawartosc N,N-bis(2-hydroksyetylo)alkilo(C8-C18)aminy\nZakres (0,4 – 5) mg/kg plynu modelowego\nMetoda wysokosprawnej chromatografii cieczowej z detekcja tandemowa spektrometria mas (HPLC-MS-MS) PB-341/LC wyd. I z dn. 12.09.2016","categories":["materials","food"],"row_index":372,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"N,N-bis(2-hydroxyethyl)alkyl(C8-C18)amine content","parameters_en":[{"name":"Range","range":"(0,4 – 5) mg/kg płynu modelowego"}],"search_en":"Plastic materials and articles intended to come into contact with food, Rubber materials and articles intended to come into contact with food, Food simulants after migration N,N-bis(2-hydroxyethyl)alkyl(C8-C18)amine content High-performance liquid chromatography with tandem mass spectrometry detection (HPLC-MS-MS) Non-Food Products and Packaging Testing Laboratory Range PB-341/LC wyd. I z dn. 12.09.2016","technique_en":"High-performance liquid chromatography with tandem mass spectrometry detection (HPLC-MS-MS)","test_object_en":"Plastic materials and articles intended to come into contact with food, Rubber materials and articles intended to come into contact with food, Food simulants after migration","lab_section_zh":"非食品产品与包装检测实验室","parameters_zh":[{"name":"范围","range":"(0,4 – 5) mg/kg płynu modelowego"}],"search_zh":"拟与食品接触的塑料材料与制品、拟与食品接触的橡胶材料与制品、迁移试验后的食品模拟物 非食品产品与包装检测实验室 范围 PB-341/LC wyd. I z dn. 12.09.2016","test_object_zh":"拟与食品接触的塑料材料与制品、拟与食品接触的橡胶材料与制品、迁移试验后的食品模拟物"},{"_id":"6a7d76396040ebab2620d3ec","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Materiały i wyroby z gumy przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji","methodology":"Migracja specyficzna N,N-bis(2-hydroksyetylo)alkilo(C8-C18)aminy (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Migracja specyficzna N,N-bis(2-hydroksyetylo)alkilo(C8-C18)aminy (z obliczeń)","reference":"PB-341/LC wyd. I z dn. 12.09.2016","norm_bases":["PB-341/LC wyd. I z dn. 12.09.2016"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Materiały i wyroby z gumy przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji Migracja specyficzna N,N-bis(2-hydroksyetylo)alkilo(C8-C18)aminy (z obliczeń) PB-341/LC wyd. I z dn. 12.09.2016 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia, Materialy i wyroby z gumy przeznaczone do kontaktu z zywnoscia, Plyny modelowe po migracji Migracja specyficzna N,N-bis(2-hydroksyetylo)alkilo(C8-C18)aminy (z obliczen) PB-341/LC wyd. I z dn. 12.09.2016","categories":["materials","food"],"row_index":373,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Specific migration of N,N-bis(2-hydroxyethyl)alkyl(C8-C18)amine (calculated)","search_en":"Plastic materials and articles intended to come into contact with food, Rubber materials and articles intended to come into contact with food, Food simulants after migration Specific migration of N,N-bis(2-hydroxyethyl)alkyl(C8-C18)amine (calculated) Non-Food Products and Packaging Testing Laboratory PB-341/LC wyd. I z dn. 12.09.2016","test_object_en":"Plastic materials and articles intended to come into contact with food, Rubber materials and articles intended to come into contact with food, Food simulants after migration","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"拟与食品接触的塑料材料与制品、拟与食品接触的橡胶材料与制品、迁移试验后的食品模拟物 非食品产品与包装检测实验室 PB-341/LC wyd. I z dn. 12.09.2016","test_object_zh":"拟与食品接触的塑料材料与制品、拟与食品接触的橡胶材料与制品、迁移试验后的食品模拟物"},{"_id":"6a7d76396040ebab2620d3ed","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Materiały i wyroby z gumy przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji","methodology":"Zawartość 2,6-di-tert-butylo-p-krezolu (BHT)","parameters":[{"name":"Zakres","range":"(1 – 25) mg/kg płynu modelowego"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość 2,6-di-tert-butylo-p-krezolu (BHT)\nZakres (1 – 25) mg/kg płynu modelowego\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PB-385 wyd. I z dn. 26.10.2018","norm_bases":["PB-385 wyd. I z dn. 26.10.2018"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Materiały i wyroby z gumy przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji Zawartość 2,6-di-tert-butylo-p-krezolu (BHT)\nZakres (1 – 25) mg/kg płynu modelowego\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PB-385 wyd. I z dn. 26.10.2018 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia, Materialy i wyroby z gumy przeznaczone do kontaktu z zywnoscia, Plyny modelowe po migracji Zawartosc 2,6-di-tert-butylo-p-krezolu (BHT)\nZakres (1 – 25) mg/kg plynu modelowego\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PB-385 wyd. I z dn. 26.10.2018","categories":["materials","food"],"row_index":374,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"2,6-di-tert-butyl-p-cresol (BHT) content","parameters_en":[{"name":"Range","range":"(1 – 25) mg/kg płynu modelowego"}],"search_en":"Plastic materials and articles intended to come into contact with food, Rubber materials and articles intended to come into contact with food, Food simulants after migration 2,6-di-tert-butyl-p-cresol (BHT) content Gas chromatography with mass spectrometry detection (GC-MS) Non-Food Products and Packaging Testing Laboratory Range PB-385 wyd. I z dn. 26.10.2018","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Plastic materials and articles intended to come into contact with food, Rubber materials and articles intended to come into contact with food, Food simulants after migration","lab_section_zh":"非食品产品与包装检测实验室","parameters_zh":[{"name":"范围","range":"(1 – 25) mg/kg płynu modelowego"}],"search_zh":"拟与食品接触的塑料材料与制品、拟与食品接触的橡胶材料与制品、迁移试验后的食品模拟物 气相色谱-质谱法（GC-MS） 非食品产品与包装检测实验室 范围 PB-385 wyd. I z dn. 26.10.2018","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"拟与食品接触的塑料材料与制品、拟与食品接触的橡胶材料与制品、迁移试验后的食品模拟物"},{"_id":"6a7d76396040ebab2620d3ee","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Materiały i wyroby z gumy przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji","methodology":"Migracja specyficzna 2,6-di-tert-butylo-p-krezolu (BHT) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Migracja specyficzna 2,6-di-tert-butylo-p-krezolu (BHT) (z obliczeń)","reference":"PB-385 wyd. I z dn. 26.10.2018","norm_bases":["PB-385 wyd. I z dn. 26.10.2018"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Materiały i wyroby z gumy przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji Migracja specyficzna 2,6-di-tert-butylo-p-krezolu (BHT) (z obliczeń) PB-385 wyd. I z dn. 26.10.2018 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia, Materialy i wyroby z gumy przeznaczone do kontaktu z zywnoscia, Plyny modelowe po migracji Migracja specyficzna 2,6-di-tert-butylo-p-krezolu (BHT) (z obliczen) PB-385 wyd. I z dn. 26.10.2018","categories":["materials","food"],"row_index":375,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Specific migration of 2,6-di-tert-butyl-p-cresol (BHT) (calculated)","search_en":"Plastic materials and articles intended to come into contact with food, Rubber materials and articles intended to come into contact with food, Food simulants after migration Specific migration of 2,6-di-tert-butyl-p-cresol (BHT) (calculated) Non-Food Products and Packaging Testing Laboratory PB-385 wyd. I z dn. 26.10.2018","test_object_en":"Plastic materials and articles intended to come into contact with food, Rubber materials and articles intended to come into contact with food, Food simulants after migration","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"拟与食品接触的塑料材料与制品、拟与食品接触的橡胶材料与制品、迁移试验后的食品模拟物 非食品产品与包装检测实验室 PB-385 wyd. I z dn. 26.10.2018","test_object_zh":"拟与食品接触的塑料材料与制品、拟与食品接触的橡胶材料与制品、迁移试验后的食品模拟物"},{"_id":"6a7d76396040ebab2620d3ef","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji","methodology":"Zawartość 9,9-bis[metoksymetylo]-9H-fluorenu","parameters":[{"name":"Zakres","range":"(0,05 – 0,5) mg/kg płynu"},{"name":"modelowego"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość 9,9-bis[metoksymetylo]-9H-fluorenu\nZakres:\nZakres (0,05 – 0,5) mg/kg płynu\nmodelowego\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PB-367 wyd. II z dn. 21.02.2018","norm_bases":["PB-367 wyd. II z dn. 21.02.2018"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji Zawartość 9,9-bis[metoksymetylo]-9H-fluorenu\nZakres:\nZakres (0,05 – 0,5) mg/kg płynu\nmodelowego\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PB-367 wyd. II z dn. 21.02.2018 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia, Plyny modelowe po migracji Zawartosc 9,9-bis[metoksymetylo]-9H-fluorenu\nZakres:\nZakres (0,05 – 0,5) mg/kg plynu\nmodelowego\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PB-367 wyd. II z dn. 21.02.2018","categories":["materials","food"],"row_index":376,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"9,9-bis[methoxymethyl]-9H-fluorene content","parameters_en":[{"name":"Range","range":"(0,05 – 0,5) mg/kg płynu"},{"name":"simulant"}],"search_en":"Plastic materials and articles intended to come into contact with food, Food simulants after migration 9,9-bis[methoxymethyl]-9H-fluorene content Gas chromatography with mass spectrometry detection (GC-MS) Non-Food Products and Packaging Testing Laboratory Range simulant PB-367 wyd. II z dn. 21.02.2018","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Plastic materials and articles intended to come into contact with food, Food simulants after migration","lab_section_zh":"非食品产品与包装检测实验室","parameters_zh":[{"name":"范围","range":"(0,05 – 0,5) mg/kg płynu"},{"name":"模拟物的"}],"search_zh":"拟与食品接触的塑料材料与制品、迁移试验后的食品模拟物 气相色谱-质谱法（GC-MS） 非食品产品与包装检测实验室 范围 模拟物的 PB-367 wyd. II z dn. 21.02.2018","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"拟与食品接触的塑料材料与制品、迁移试验后的食品模拟物"},{"_id":"6a7d76396040ebab2620d3f0","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji","methodology":"Migracja specyficzna 9,9-bis[metoksymetylo]-9H-fluorenu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Migracja specyficzna 9,9-bis[metoksymetylo]-9H-fluorenu (z obliczeń)","reference":"PB-367 wyd. II z dn. 21.02.2018","norm_bases":["PB-367 wyd. II z dn. 21.02.2018"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji Migracja specyficzna 9,9-bis[metoksymetylo]-9H-fluorenu (z obliczeń) PB-367 wyd. II z dn. 21.02.2018 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia, Plyny modelowe po migracji Migracja specyficzna 9,9-bis[metoksymetylo]-9H-fluorenu (z obliczen) PB-367 wyd. II z dn. 21.02.2018","categories":["materials","food"],"row_index":377,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Specific migration of 9,9-bis[methoxymethyl]-9H-fluorene (calculated)","search_en":"Plastic materials and articles intended to come into contact with food, Food simulants after migration Specific migration of 9,9-bis[methoxymethyl]-9H-fluorene (calculated) Non-Food Products and Packaging Testing Laboratory PB-367 wyd. II z dn. 21.02.2018","test_object_en":"Plastic materials and articles intended to come into contact with food, Food simulants after migration","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"拟与食品接触的塑料材料与制品、迁移试验后的食品模拟物 非食品产品与包装检测实验室 PB-367 wyd. II z dn. 21.02.2018","test_object_zh":"拟与食品接触的塑料材料与制品、迁移试验后的食品模拟物"},{"_id":"6a7d76396040ebab2620d3f1","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji","methodology":"Zawartość aldehydu octowego","parameters":[{"name":"Zakres","range":"(0,5 – 20) mg/kg płynu"},{"name":"modelowego"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją płomieniowo-jonizacyjną (HS-GC-FID)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją płomieniowo-jonizacyjną (HS-GC-FID)"],"computed":[],"activity":"Zawartość aldehydu octowego\nZakres:\nZakres (0,5 – 20) mg/kg płynu\nmodelowego\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją płomieniowo-jonizacyjną (HS-GC-FID)","reference":"PB-395 wyd. I z dn. 15.05.2019","norm_bases":["PB-395 wyd. I z dn. 15.05.2019"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji Zawartość aldehydu octowego\nZakres:\nZakres (0,5 – 20) mg/kg płynu\nmodelowego\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją płomieniowo-jonizacyjną (HS-GC-FID) PB-395 wyd. I z dn. 15.05.2019 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia, Plyny modelowe po migracji Zawartosc aldehydu octowego\nZakres:\nZakres (0,5 – 20) mg/kg plynu\nmodelowego\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej z detekcja plomieniowo-jonizacyjna (HS-GC-FID) PB-395 wyd. I z dn. 15.05.2019","categories":["materials","food"],"row_index":378,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Acetic aldehyde content","parameters_en":[{"name":"Range","range":"(0,5 – 20) mg/kg płynu"},{"name":"simulant"}],"search_en":"Plastic materials and articles intended to come into contact with food, Food simulants after migration Acetic aldehyde content Headspace gas chromatography with flame ionization detection (HS-GC-FID) Non-Food Products and Packaging Testing Laboratory Range simulant PB-395 wyd. I z dn. 15.05.2019","technique_en":"Headspace gas chromatography with flame ionization detection (HS-GC-FID)","test_object_en":"Plastic materials and articles intended to come into contact with food, Food simulants after migration","lab_section_zh":"非食品产品与包装检测实验室","parameters_zh":[{"name":"范围","range":"(0,5 – 20) mg/kg płynu"},{"name":"模拟物的"}],"search_zh":"拟与食品接触的塑料材料与制品、迁移试验后的食品模拟物 顶空气相色谱-火焰离子化检测法（HS-GC-FID） 非食品产品与包装检测实验室 范围 模拟物的 PB-395 wyd. I z dn. 15.05.2019","technique_zh":"顶空气相色谱-火焰离子化检测法（HS-GC-FID）","test_object_zh":"拟与食品接触的塑料材料与制品、迁移试验后的食品模拟物"},{"_id":"6a7d76396040ebab2620d3f2","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji","methodology":"Migracja specyficzna aldehydu octowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Migracja specyficzna aldehydu octowego (z obliczeń)","reference":"PB-395 wyd. I z dn. 15.05.2019","norm_bases":["PB-395 wyd. I z dn. 15.05.2019"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji Migracja specyficzna aldehydu octowego (z obliczeń) PB-395 wyd. I z dn. 15.05.2019 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia, Plyny modelowe po migracji Migracja specyficzna aldehydu octowego (z obliczen) PB-395 wyd. I z dn. 15.05.2019","categories":["materials","food"],"row_index":379,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Specific migration of acetaldehyde (calculated)","search_en":"Plastic materials and articles intended to come into contact with food, Food simulants after migration Specific migration of acetaldehyde (calculated) Non-Food Products and Packaging Testing Laboratory PB-395 wyd. I z dn. 15.05.2019","test_object_en":"Plastic materials and articles intended to come into contact with food, Food simulants after migration","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"拟与食品接触的塑料材料与制品、迁移试验后的食品模拟物 非食品产品与包装检测实验室 PB-395 wyd. I z dn. 15.05.2019","test_object_zh":"拟与食品接触的塑料材料与制品、迁移试验后的食品模拟物"},{"_id":"6a7d76396040ebab2620d3f3","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji","methodology":"Zawartość 1,3,5-tris(3,5-di-tert-butylo-4-hydroksybenzylo)-1,3,5-triazyno-2,4,6 (1H,3H,5H)-trionu","parameters":[{"name":"Zakres","range":"(0,5 – 15) mg/kg płynu"},{"name":"modelowego"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/Vis)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/Vis)"],"computed":[],"activity":"Zawartość 1,3,5-tris(3,5-di-tert-butylo-4-hydroksybenzylo)-1,3,5-triazyno-2,4,6 (1H,3H,5H)-trionu\nZakres:\nZakres (0,5 – 15) mg/kg płynu\nmodelowego\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/Vis)","reference":"PB-300 wyd. I z dn. 10.08.2019","norm_bases":["PB-300 wyd. I z dn. 10.08.2019"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji Zawartość 1,3,5-tris(3,5-di-tert-butylo-4-hydroksybenzylo)-1,3,5-triazyno-2,4,6 (1H,3H,5H)-trionu\nZakres:\nZakres (0,5 – 15) mg/kg płynu\nmodelowego\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/Vis) PB-300 wyd. I z dn. 10.08.2019 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia, Plyny modelowe po migracji Zawartosc 1,3,5-tris(3,5-di-tert-butylo-4-hydroksybenzylo)-1,3,5-triazyno-2,4,6 (1H,3H,5H)-trionu\nZakres:\nZakres (0,5 – 15) mg/kg plynu\nmodelowego\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV/Vis) PB-300 wyd. I z dn. 10.08.2019","categories":["materials","food"],"row_index":380,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"1,3,5-tris(3,5-di-tert-butyl-4-hydroxybenzyl)-1,3,5-triazine-2,4,6 (1H,3H,5H)-trione content","parameters_en":[{"name":"Range","range":"(0,5 – 15) mg/kg płynu"},{"name":"simulant"}],"search_en":"Plastic materials and articles intended to come into contact with food, Food simulants after migration 1,3,5-tris(3,5-di-tert-butyl-4-hydroxybenzyl)-1,3,5-triazine-2,4,6 (1H,3H,5H)-trione content High-performance liquid chromatography with spectrophotometric detection (HPLC-UV/Vis) Non-Food Products and Packaging Testing Laboratory Range simulant PB-300 wyd. I z dn. 10.08.2019","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV/Vis)","test_object_en":"Plastic materials and articles intended to come into contact with food, Food simulants after migration","lab_section_zh":"非食品产品与包装检测实验室","parameters_zh":[{"name":"范围","range":"(0,5 – 15) mg/kg płynu"},{"name":"模拟物的"}],"search_zh":"拟与食品接触的塑料材料与制品、迁移试验后的食品模拟物 高效液相色谱-分光光度检测法（HPLC-UV/Vis） 非食品产品与包装检测实验室 范围 模拟物的 PB-300 wyd. I z dn. 10.08.2019","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV/Vis）","test_object_zh":"拟与食品接触的塑料材料与制品、迁移试验后的食品模拟物"},{"_id":"6a7d76396040ebab2620d3f4","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji","methodology":"Migracja specyficzna 1,3,5-tris(3,5-di-tert-butylo-4-hydroksybenzylo)-1,3,5-triazyno-2,4,6 (1H,3H,5H)-trionu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Migracja specyficzna 1,3,5-tris(3,5-di-tert-butylo-4-hydroksybenzylo)-1,3,5-triazyno-2,4,6 (1H,3H,5H)-trionu (z obliczeń)","reference":"PB-300 wyd. I z dn. 10.08.2019","norm_bases":["PB-300 wyd. I z dn. 10.08.2019"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji Migracja specyficzna 1,3,5-tris(3,5-di-tert-butylo-4-hydroksybenzylo)-1,3,5-triazyno-2,4,6 (1H,3H,5H)-trionu (z obliczeń) PB-300 wyd. I z dn. 10.08.2019 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia, Plyny modelowe po migracji Migracja specyficzna 1,3,5-tris(3,5-di-tert-butylo-4-hydroksybenzylo)-1,3,5-triazyno-2,4,6 (1H,3H,5H)-trionu (z obliczen) PB-300 wyd. I z dn. 10.08.2019","categories":["materials","food"],"row_index":381,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Specific migration of 1,3,5-tris(3,5-di-tert-butyl-4-hydroxybenzyl)-1,3,5-triazine-2,4,6 (1H,3H,5H)-trione (calculated)","search_en":"Plastic materials and articles intended to come into contact with food, Food simulants after migration Specific migration of 1,3,5-tris(3,5-di-tert-butyl-4-hydroxybenzyl)-1,3,5-triazine-2,4,6 (1H,3H,5H)-trione (calculated) Non-Food Products and Packaging Testing Laboratory PB-300 wyd. I z dn. 10.08.2019","test_object_en":"Plastic materials and articles intended to come into contact with food, Food simulants after migration","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"拟与食品接触的塑料材料与制品、迁移试验后的食品模拟物 非食品产品与包装检测实验室 PB-300 wyd. I z dn. 10.08.2019","test_object_zh":"拟与食品接触的塑料材料与制品、迁移试验后的食品模拟物"},{"_id":"6a7d76396040ebab2620d3f5","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji","methodology":"Migracja globalna do olejów roślinnych","parameters":[{"name":"Zakres","range":"(2,0 – 100,0) mg/dm2"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Migracja globalna do olejów roślinnych\nZakres (2,0 – 100,0) mg/dm2\nMetoda wagowa","reference":"PN-EN 1186-2:2022-12","norm_bases":["PN-EN 1186-2:2022-12"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Płyny modelowe po migracji Migracja globalna do olejów roślinnych\nZakres (2,0 – 100,0) mg/dm2\nMetoda wagowa PN-EN 1186-2:2022-12 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia, Plyny modelowe po migracji Migracja globalna do olejow roslinnych\nZakres (2,0 – 100,0) mg/dm2\nMetoda wagowa PN-EN 1186-2:2022-12","categories":["materials","food","petro"],"row_index":382,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Overall migration into vegetable oils","parameters_en":[{"name":"Range","range":"(2,0 – 100,0) mg/dm2"}],"search_en":"Plastic materials and articles intended to come into contact with food, Food simulants after migration Overall migration into vegetable oils Gravimetric method Non-Food Products and Packaging Testing Laboratory Range PN-EN 1186-2:2022-12","technique_en":"Gravimetric method","test_object_en":"Plastic materials and articles intended to come into contact with food, Food simulants after migration","lab_section_zh":"非食品产品与包装检测实验室","parameters_zh":[{"name":"范围","range":"(2,0 – 100,0) mg/dm2"}],"search_zh":"拟与食品接触的塑料材料与制品、迁移试验后的食品模拟物 重量法 非食品产品与包装检测实验室 范围 PN-EN 1186-2:2022-12","technique_zh":"重量法","test_object_zh":"拟与食品接触的塑料材料与制品、迁移试验后的食品模拟物"},{"_id":"6a7d76396040ebab2620d3f6","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Zabawki, materiały na zabawki, tworzywa sztuczne","methodology":"Stężenie formaldehydu w ekstrakcie","parameters":[{"name":"Zakres","range":"(0,5 – 5,0) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie formaldehydu w ekstrakcie\nZakres (0,5 – 5,0) mg/kg\nMetoda spektrofotometryczna","reference":"PN-EN-71-11:2007","norm_bases":["PN-EN-71-11:2007"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zabawki, materiały na zabawki, tworzywa sztuczne Stężenie formaldehydu w ekstrakcie\nZakres (0,5 – 5,0) mg/kg\nMetoda spektrofotometryczna PN-EN-71-11:2007 Zabawki, materialy na zabawki, tworzywa sztuczne Stezenie formaldehydu w ekstrakcie\nZakres (0,5 – 5,0) mg/kg\nMetoda spektrofotometryczna PN-EN-71-11:2007","categories":["materials"],"row_index":383,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Formaldehyde concentration in the extract","parameters_en":[{"name":"Range","range":"(0,5 – 5,0) mg/kg"}],"search_en":"Toys, materials for toys, plastics Formaldehyde concentration in the extract Spectrophotometric method Non-Food Products and Packaging Testing Laboratory Range PN-EN-71-11:2007","technique_en":"Spectrophotometric method","test_object_en":"Toys, materials for toys, plastics","lab_section_zh":"非食品产品与包装检测实验室","parameters_zh":[{"name":"范围","range":"(0,5 – 5,0) mg/kg"}],"search_zh":"分光光度法 非食品产品与包装检测实验室 范围 PN-EN-71-11:2007","technique_zh":"分光光度法"},{"_id":"6a7d76396040ebab2620d3f7","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Zabawki, materiały na zabawki z tekstyliów, tekstylia","methodology":"Zawartość formaldehydu","parameters":[{"name":"Zakres","range":"(16 – 3500) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość formaldehydu\nZakres (16 – 3500) mg/kg\nMetoda spektrofotometryczna","reference":"PN-EN ISO 14184-1:2011","norm_bases":["PN-EN ISO 14184-1:2011"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zabawki, materiały na zabawki z tekstyliów, tekstylia Zawartość formaldehydu\nZakres (16 – 3500) mg/kg\nMetoda spektrofotometryczna PN-EN ISO 14184-1:2011 Zabawki, materialy na zabawki z tekstyliow, tekstylia Zawartosc formaldehydu\nZakres (16 – 3500) mg/kg\nMetoda spektrofotometryczna PN-EN ISO 14184-1:2011","categories":["materials"],"row_index":384,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Formaldehyde content","parameters_en":[{"name":"Range","range":"(16 – 3500) mg/kg"}],"search_en":"Toys, textile materials for toys, textiles Formaldehyde content Spectrophotometric method Non-Food Products and Packaging Testing Laboratory Range PN-EN ISO 14184-1:2011","technique_en":"Spectrophotometric method","test_object_en":"Toys, textile materials for toys, textiles","lab_section_zh":"非食品产品与包装检测实验室","parameters_zh":[{"name":"范围","range":"(16 – 3500) mg/kg"}],"search_zh":"甲醛含量 分光光度法 非食品产品与包装检测实验室 范围 PN-EN ISO 14184-1:2011","technique_zh":"分光光度法","methodology_zh":"甲醛含量"},{"_id":"6a7d76396040ebab2620d3f8","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Sprzęt elektryczny i elektroniczny oraz jego elementy polimerowe, tekstylne, papierowe i elektroniczne, materiały stosowane do produkcji sprzętu elektrycznego i elektronicznego oraz opakowań","methodology":"Zawartość pierwiastków","parameters":[{"name":"Al","range":"(50 – 3000) mg/kg"},{"name":"Sb","range":"(5,0 – 3000) mg/kg"},{"name":"As","range":"(5,0 – 3000) mg/kg"},{"name":"Ba","range":"(50 – 3000) mg/kg"},{"name":"B","range":"(50 – 3000) mg/kg"},{"name":"Cd","range":"(5,0 – 3000) mg/kg"},{"name":"Cr ogólny","range":"(5,0 – 3000) mg/kg"},{"name":"Co","range":"(5,0 – 3000) mg/kg"},{"name":"Cu","range":"(50 – 3000) mg/kg"},{"name":"Pb","range":"(5,0 – 3000) mg/kg"},{"name":"Mn","range":"(50 – 3000) mg/kg"},{"name":"Hg","range":"(5,0 – 3000) mg/kg"},{"name":"Ni","range":"(5,0 – 3000) mg/kg"},{"name":"Se","range":"(5,0 – 3000) mg/kg"},{"name":"Sr","range":"(50 – 3000) mg/kg"},{"name":"Sn ogólna","range":"(50 – 3000) mg/kg"},{"name":"Zn","range":"(50 – 3000) mg/kg"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\nAl (50 – 3000) mg/kg\nSb (5,0 – 3000) mg/kg\nAs (5,0 – 3000) mg/kg\nBa (50 – 3000) mg/kg\nB (50 – 3000) mg/kg\nCd (5,0 – 3000) mg/kg\nCr ogólny (5,0 – 3000) mg/kg\nCo (5,0 – 3000) mg/kg\nCu (50 – 3000) mg/kg\nPb (5,0 – 3000) mg/kg\nMn (50 – 3000) mg/kg\nHg (5,0 – 3000) mg/kg\nNi (5,0 – 3000) mg/kg\nSe (5,0 – 3000) mg/kg\nSr (50 – 3000) mg/kg\nSn ogólna (50 – 3000) mg/kg\nZn (50 – 3000) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN 62321-4:2014-08 +A1:2017-12 | PN-EN 62321-5:2014-08","norm_bases":["PN-EN 62321-4:2014-08 +A1:2017-12","PN-EN 62321-5:2014-08"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sprzęt elektryczny i elektroniczny oraz jego elementy polimerowe, tekstylne, papierowe i elektroniczne, materiały stosowane do produkcji sprzętu elektrycznego i elektronicznego oraz opakowań Zawartość pierwiastków\nZakres:\nAl (50 – 3000) mg/kg\nSb (5,0 – 3000) mg/kg\nAs (5,0 – 3000) mg/kg\nBa (50 – 3000) mg/kg\nB (50 – 3000) mg/kg\nCd (5,0 – 3000) mg/kg\nCr ogólny (5,0 – 3000) mg/kg\nCo (5,0 – 3000) mg/kg\nCu (50 – 3000) mg/kg\nPb (5,0 – 3000) mg/kg\nMn (50 – 3000) mg/kg\nHg (5,0 – 3000) mg/kg\nNi (5,0 – 3000) mg/kg\nSe (5,0 – 3000) mg/kg\nSr (50 – 3000) mg/kg\nSn ogólna (50 – 3000) mg/kg\nZn (50 – 3000) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN 62321-4:2014-08 +A1:2017-12 | PN-EN 62321-5:2014-08 Sprzet elektryczny i elektroniczny oraz jego elementy polimerowe, tekstylne, papierowe i elektroniczne, materialy stosowane do produkcji sprzetu elektrycznego i elektronicznego oraz opakowan Zawartosc pierwiastkow\nZakres:\nAl (50 – 3000) mg/kg\nSb (5,0 – 3000) mg/kg\nAs (5,0 – 3000) mg/kg\nBa (50 – 3000) mg/kg\nB (50 – 3000) mg/kg\nCd (5,0 – 3000) mg/kg\nCr ogolny (5,0 – 3000) mg/kg\nCo (5,0 – 3000) mg/kg\nCu (50 – 3000) mg/kg\nPb (5,0 – 3000) mg/kg\nMn (50 – 3000) mg/kg\nHg (5,0 – 3000) mg/kg\nNi (5,0 – 3000) mg/kg\nSe (5,0 – 3000) mg/kg\nSr (50 – 3000) mg/kg\nSn ogolna (50 – 3000) mg/kg\nZn (50 – 3000) mg/kg\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN 62321-4:2014-08 +A1:2017-12 | PN-EN 62321-5:2014-08","categories":["materials","electronics"],"row_index":385,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Element content","parameters_en":[{"name":"Al","range":"(50 – 3000) mg/kg"},{"name":"Sb","range":"(5,0 – 3000) mg/kg"},{"name":"As","range":"(5,0 – 3000) mg/kg"},{"name":"Ba","range":"(50 – 3000) mg/kg"},{"name":"B","range":"(50 – 3000) mg/kg"},{"name":"Cd","range":"(5,0 – 3000) mg/kg"},{"name":"Total Cr","range":"(5,0 – 3000) mg/kg"},{"name":"Co","range":"(5,0 – 3000) mg/kg"},{"name":"Cu","range":"(50 – 3000) mg/kg"},{"name":"Pb","range":"(5,0 – 3000) mg/kg"},{"name":"Mn","range":"(50 – 3000) mg/kg"},{"name":"Hg","range":"(5,0 – 3000) mg/kg"},{"name":"Ni","range":"(5,0 – 3000) mg/kg"},{"name":"Se","range":"(5,0 – 3000) mg/kg"},{"name":"Sr","range":"(50 – 3000) mg/kg"},{"name":"Total Sn","range":"(50 – 3000) mg/kg"},{"name":"Zn","range":"(50 – 3000) mg/kg"}],"search_en":"Electrical and electronic equipment and its polymer, textile, paper and electronic components, materials used in the manufacture of electrical and electronic equipment and packaging Element content Inductively coupled plasma mass spectrometry (ICP-MS) Non-Food Products and Packaging Testing Laboratory Al Sb As Ba B Cd Total Cr Co Cu Pb Mn Hg Ni Se Sr Total Sn Zn PN-EN 62321-4:2014-08 +A1:2017-12 | PN-EN 62321-5:2014-08","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Electrical and electronic equipment and its polymer, textile, paper and electronic components, materials used in the manufacture of electrical and electronic equipment and packaging","lab_section_zh":"非食品产品与包装检测实验室","methodology_zh":"元素含量","parameters_zh":[{"name":"Al","range":"(50 – 3000) mg/kg"},{"name":"Sb","range":"(5,0 – 3000) mg/kg"},{"name":"As","range":"(5,0 – 3000) mg/kg"},{"name":"Ba","range":"(50 – 3000) mg/kg"},{"name":"B","range":"(50 – 3000) mg/kg"},{"name":"Cd","range":"(5,0 – 3000) mg/kg"},{"name":"Cr ogólny","range":"(5,0 – 3000) mg/kg"},{"name":"Co","range":"(5,0 – 3000) mg/kg"},{"name":"Cu","range":"(50 – 3000) mg/kg"},{"name":"Pb","range":"(5,0 – 3000) mg/kg"},{"name":"Mn","range":"(50 – 3000) mg/kg"},{"name":"Hg","range":"(5,0 – 3000) mg/kg"},{"name":"Ni","range":"(5,0 – 3000) mg/kg"},{"name":"Se","range":"(5,0 – 3000) mg/kg"},{"name":"Sr","range":"(50 – 3000) mg/kg"},{"name":"Sn ogólna","range":"(50 – 3000) mg/kg"},{"name":"Zn","range":"(50 – 3000) mg/kg"}],"search_zh":"电气与电子设备及其高分子、纺织、纸质与电子部件，电气与电子设备及包装生产用材料 元素含量 电感耦合等离子体质谱法（ICP-MS） 非食品产品与包装检测实验室 Al Sb As Ba B Cd Co Cu Pb Mn Ni Se Sr Zn PN-EN 62321-4:2014-08 +A1:2017-12 | PN-EN 62321-5:2014-08","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"电气与电子设备及其高分子、纺织、纸质与电子部件，电气与电子设备及包装生产用材料"},{"_id":"6a7d76396040ebab2620d3f9","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Sprzęt elektryczny i elektroniczny oraz jego elementy polimerowe, tekstylne, papierowe i elektroniczne, materiały stosowane do produkcji sprzętu elektrycznego i elektronicznego oraz opakowań","methodology":"Stężenie polibromowanych bifenyli (PBB) i polibromowanych eterów difenylowych (PBDE) w ekstrakcie rozpuszczalnikowym z materiału obiektu","parameters":[{"name":"PBB","range":"(0,03 – 1,5) %"},{"name":"PDBE","range":"(0,03 – 1,5) %"},{"name":"Zawartość polibromowanych bifenyli (PBB) i polibromowanych eterów difenylowych (PBDE) (z obliczeń) cechy/metoda"}],"technique":"Metoda chromatografii gazowej ze spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej ze spektrometrią mas (GC-MS)"],"computed":[],"activity":"Stężenie polibromowanych bifenyli (PBB) i polibromowanych eterów difenylowych (PBDE) w ekstrakcie rozpuszczalnikowym z materiału obiektu\nZakres:\nPBB (0,03 – 1,5) %\nPDBE (0,03 – 1,5) %\nZawartość polibromowanych bifenyli (PBB) i polibromowanych eterów difenylowych (PBDE) (z obliczeń) cechy/metoda\nMetoda chromatografii gazowej ze spektrometrią mas (GC-MS)","reference":"PN-EN 62321-6:2015-10","norm_bases":["PN-EN 62321-6:2015-10"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sprzęt elektryczny i elektroniczny oraz jego elementy polimerowe, tekstylne, papierowe i elektroniczne, materiały stosowane do produkcji sprzętu elektrycznego i elektronicznego oraz opakowań Stężenie polibromowanych bifenyli (PBB) i polibromowanych eterów difenylowych (PBDE) w ekstrakcie rozpuszczalnikowym z materiału obiektu\nZakres:\nPBB (0,03 – 1,5) %\nPDBE (0,03 – 1,5) %\nZawartość polibromowanych bifenyli (PBB) i polibromowanych eterów difenylowych (PBDE) (z obliczeń) cechy/metoda\nMetoda chromatografii gazowej ze spektrometrią mas (GC-MS) PN-EN 62321-6:2015-10 Sprzet elektryczny i elektroniczny oraz jego elementy polimerowe, tekstylne, papierowe i elektroniczne, materialy stosowane do produkcji sprzetu elektrycznego i elektronicznego oraz opakowan Stezenie polibromowanych bifenyli (PBB) i polibromowanych eterow difenylowych (PBDE) w ekstrakcie rozpuszczalnikowym z materialu obiektu\nZakres:\nPBB (0,03 – 1,5) %\nPDBE (0,03 – 1,5) %\nZawartosc polibromowanych bifenyli (PBB) i polibromowanych eterow difenylowych (PBDE) (z obliczen) cechy/metoda\nMetoda chromatografii gazowej ze spektrometria mas (GC-MS) PN-EN 62321-6:2015-10","categories":["materials","electronics"],"row_index":386,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Concentration of polybrominated biphenyls (PBB) and polybrominated diphenyl ethers (PBDE) in a solvent extract from the object material","parameters_en":[{"name":"PBB","range":"(0,03 – 1,5) %"},{"name":"PDBE","range":"(0,03 – 1,5) %"},{"name":"Content of polybrominated biphenyls (PBB) and polybrominated diphenyl ethers (PBDE) (calculated) characteristics/method"}],"search_en":"Electrical and electronic equipment and its polymer, textile, paper and electronic components, materials used in the manufacture of electrical and electronic equipment and packaging Concentration of polybrominated biphenyls (PBB) and polybrominated diphenyl ethers (PBDE) in a solvent extract from the object material Gas chromatography with mass spectrometry (GC-MS) Non-Food Products and Packaging Testing Laboratory PBB PDBE Content of polybrominated biphenyls (PBB) and polybrominated diphenyl ethers (PBDE) (calculated) characteristics/method PN-EN 62321-6:2015-10","technique_en":"Gas chromatography with mass spectrometry (GC-MS)","test_object_en":"Electrical and electronic equipment and its polymer, textile, paper and electronic components, materials used in the manufacture of electrical and electronic equipment and packaging","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"电气与电子设备及其高分子、纺织、纸质与电子部件，电气与电子设备及包装生产用材料 气相色谱-质谱法（GC-MS） 非食品产品与包装检测实验室 PN-EN 62321-6:2015-10","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"电气与电子设备及其高分子、纺织、纸质与电子部件，电气与电子设备及包装生产用材料"},{"_id":"6a7d76396040ebab2620d3fa","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury","methodology":"Zawartość pierwiastków","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość pierwiastków","reference":"PB-233/ICP wyd. II z dn. 15.11.2017","norm_bases":["PB-233/ICP wyd. II z dn. 15.11.2017"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury Zawartość pierwiastków PB-233/ICP wyd. II z dn. 15.11.2017 Materialy i wyroby z tworzyw sztucznych, Materialy i wyroby z papieru, tektury Zawartosc pierwiastkow PB-233/ICP wyd. II z dn. 15.11.2017","categories":["materials"],"row_index":387,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Element content","search_en":"Plastic materials and articles, Paper and board materials and articles Element content Non-Food Products and Packaging Testing Laboratory PB-233/ICP wyd. II z dn. 15.11.2017","test_object_en":"Plastic materials and articles, Paper and board materials and articles","lab_section_zh":"非食品产品与包装检测实验室","methodology_zh":"元素含量","search_zh":"塑料材料与制品、纸与纸板材料与制品 元素含量 非食品产品与包装检测实验室 PB-233/ICP wyd. II z dn. 15.11.2017","test_object_zh":"塑料材料与制品、纸与纸板材料与制品"},{"_id":"6a7d76396040ebab2620d3fb","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury","methodology":"Al (50 – 500) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Al (50 – 500) mg/kg","reference":"PB-233/ICP wyd. II z dn. 15.11.2017","norm_bases":["PB-233/ICP wyd. II z dn. 15.11.2017"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury Al (50 – 500) mg/kg PB-233/ICP wyd. II z dn. 15.11.2017 Materialy i wyroby z tworzyw sztucznych, Materialy i wyroby z papieru, tektury Al (50 – 500) mg/kg PB-233/ICP wyd. II z dn. 15.11.2017","categories":["materials"],"row_index":388,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Al (50 – 500) mg/kg","search_en":"Plastic materials and articles, Paper and board materials and articles Al (50 – 500) mg/kg Non-Food Products and Packaging Testing Laboratory PB-233/ICP wyd. II z dn. 15.11.2017","test_object_en":"Plastic materials and articles, Paper and board materials and articles","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"塑料材料与制品、纸与纸板材料与制品 非食品产品与包装检测实验室 PB-233/ICP wyd. II z dn. 15.11.2017","test_object_zh":"塑料材料与制品、纸与纸板材料与制品"},{"_id":"6a7d76396040ebab2620d3fc","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury","methodology":"Sb (5,0 – 500) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Sb (5,0 – 500) mg/kg","reference":"PB-233/ICP wyd. II z dn. 15.11.2017","norm_bases":["PB-233/ICP wyd. II z dn. 15.11.2017"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury Sb (5,0 – 500) mg/kg PB-233/ICP wyd. II z dn. 15.11.2017 Materialy i wyroby z tworzyw sztucznych, Materialy i wyroby z papieru, tektury Sb (5,0 – 500) mg/kg PB-233/ICP wyd. II z dn. 15.11.2017","categories":["materials"],"row_index":389,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Sb (5,0 – 500) mg/kg","search_en":"Plastic materials and articles, Paper and board materials and articles Sb (5,0 – 500) mg/kg Non-Food Products and Packaging Testing Laboratory PB-233/ICP wyd. II z dn. 15.11.2017","test_object_en":"Plastic materials and articles, Paper and board materials and articles","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"塑料材料与制品、纸与纸板材料与制品 非食品产品与包装检测实验室 PB-233/ICP wyd. II z dn. 15.11.2017","test_object_zh":"塑料材料与制品、纸与纸板材料与制品"},{"_id":"6a7d76396040ebab2620d3fd","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury","methodology":"As (5,0 – 500) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"As (5,0 – 500) mg/kg","reference":"PB-233/ICP wyd. II z dn. 15.11.2017","norm_bases":["PB-233/ICP wyd. II z dn. 15.11.2017"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury As (5,0 – 500) mg/kg PB-233/ICP wyd. II z dn. 15.11.2017 Materialy i wyroby z tworzyw sztucznych, Materialy i wyroby z papieru, tektury As (5,0 – 500) mg/kg PB-233/ICP wyd. II z dn. 15.11.2017","categories":["materials"],"row_index":390,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"As (5,0 – 500) mg/kg","search_en":"Plastic materials and articles, Paper and board materials and articles As (5,0 – 500) mg/kg Non-Food Products and Packaging Testing Laboratory PB-233/ICP wyd. II z dn. 15.11.2017","test_object_en":"Plastic materials and articles, Paper and board materials and articles","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"塑料材料与制品、纸与纸板材料与制品 非食品产品与包装检测实验室 PB-233/ICP wyd. II z dn. 15.11.2017","test_object_zh":"塑料材料与制品、纸与纸板材料与制品"},{"_id":"6a7d76396040ebab2620d3fe","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury","methodology":"Ba (50 – 500) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ba (50 – 500) mg/kg","reference":"PB-233/ICP wyd. II z dn. 15.11.2017","norm_bases":["PB-233/ICP wyd. II z dn. 15.11.2017"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury Ba (50 – 500) mg/kg PB-233/ICP wyd. II z dn. 15.11.2017 Materialy i wyroby z tworzyw sztucznych, Materialy i wyroby z papieru, tektury Ba (50 – 500) mg/kg PB-233/ICP wyd. II z dn. 15.11.2017","categories":["materials"],"row_index":391,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Ba (50 – 500) mg/kg","search_en":"Plastic materials and articles, Paper and board materials and articles Ba (50 – 500) mg/kg Non-Food Products and Packaging Testing Laboratory PB-233/ICP wyd. II z dn. 15.11.2017","test_object_en":"Plastic materials and articles, Paper and board materials and articles","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"塑料材料与制品、纸与纸板材料与制品 非食品产品与包装检测实验室 PB-233/ICP wyd. II z dn. 15.11.2017","test_object_zh":"塑料材料与制品、纸与纸板材料与制品"},{"_id":"6a7d76396040ebab2620d3ff","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury","methodology":"B (50 – 500) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"B (50 – 500) mg/kg","reference":"PB-233/ICP wyd. II z dn. 15.11.2017","norm_bases":["PB-233/ICP wyd. II z dn. 15.11.2017"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury B (50 – 500) mg/kg PB-233/ICP wyd. II z dn. 15.11.2017 Materialy i wyroby z tworzyw sztucznych, Materialy i wyroby z papieru, tektury B (50 – 500) mg/kg PB-233/ICP wyd. II z dn. 15.11.2017","categories":["materials"],"row_index":392,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"B (50 – 500) mg/kg","search_en":"Plastic materials and articles, Paper and board materials and articles B (50 – 500) mg/kg Non-Food Products and Packaging Testing Laboratory PB-233/ICP wyd. II z dn. 15.11.2017","test_object_en":"Plastic materials and articles, Paper and board materials and articles","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"塑料材料与制品、纸与纸板材料与制品 非食品产品与包装检测实验室 PB-233/ICP wyd. II z dn. 15.11.2017","test_object_zh":"塑料材料与制品、纸与纸板材料与制品"},{"_id":"6a7d76396040ebab2620d400","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury","methodology":"Cd (0,5 – 500) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cd (0,5 – 500) mg/kg","reference":"PB-233/ICP wyd. II z dn. 15.11.2017","norm_bases":["PB-233/ICP wyd. II z dn. 15.11.2017"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury Cd (0,5 – 500) mg/kg PB-233/ICP wyd. II z dn. 15.11.2017 Materialy i wyroby z tworzyw sztucznych, Materialy i wyroby z papieru, tektury Cd (0,5 – 500) mg/kg PB-233/ICP wyd. II z dn. 15.11.2017","categories":["materials"],"row_index":393,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Cd (0,5 – 500) mg/kg","search_en":"Plastic materials and articles, Paper and board materials and articles Cd (0,5 – 500) mg/kg Non-Food Products and Packaging Testing Laboratory PB-233/ICP wyd. II z dn. 15.11.2017","test_object_en":"Plastic materials and articles, Paper and board materials and articles","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"塑料材料与制品、纸与纸板材料与制品 非食品产品与包装检测实验室 PB-233/ICP wyd. II z dn. 15.11.2017","test_object_zh":"塑料材料与制品、纸与纸板材料与制品"},{"_id":"6a7d76396040ebab2620d401","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury","methodology":"Cr (ogólny) (2,0 – 500) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cr (ogólny) (2,0 – 500) mg/kg","reference":"PB-233/ICP wyd. II z dn. 15.11.2017","norm_bases":["PB-233/ICP wyd. II z dn. 15.11.2017"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury Cr (ogólny) (2,0 – 500) mg/kg PB-233/ICP wyd. II z dn. 15.11.2017 Materialy i wyroby z tworzyw sztucznych, Materialy i wyroby z papieru, tektury Cr (ogolny) (2,0 – 500) mg/kg PB-233/ICP wyd. II z dn. 15.11.2017","categories":["materials"],"row_index":394,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Cr (total) (2,0 – 500) mg/kg","search_en":"Plastic materials and articles, Paper and board materials and articles Cr (total) (2,0 – 500) mg/kg Non-Food Products and Packaging Testing Laboratory PB-233/ICP wyd. II z dn. 15.11.2017","test_object_en":"Plastic materials and articles, Paper and board materials and articles","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"塑料材料与制品、纸与纸板材料与制品 非食品产品与包装检测实验室 PB-233/ICP wyd. II z dn. 15.11.2017","test_object_zh":"塑料材料与制品、纸与纸板材料与制品"},{"_id":"6a7d76396040ebab2620d402","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury","methodology":"Co (5,0 – 500) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Co (5,0 – 500) mg/kg","reference":"PB-233/ICP wyd. II z dn. 15.11.2017","norm_bases":["PB-233/ICP wyd. II z dn. 15.11.2017"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury Co (5,0 – 500) mg/kg PB-233/ICP wyd. II z dn. 15.11.2017 Materialy i wyroby z tworzyw sztucznych, Materialy i wyroby z papieru, tektury Co (5,0 – 500) mg/kg PB-233/ICP wyd. II z dn. 15.11.2017","categories":["materials"],"row_index":395,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Co (5,0 – 500) mg/kg","search_en":"Plastic materials and articles, Paper and board materials and articles Co (5,0 – 500) mg/kg Non-Food Products and Packaging Testing Laboratory PB-233/ICP wyd. II z dn. 15.11.2017","test_object_en":"Plastic materials and articles, Paper and board materials and articles","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"塑料材料与制品、纸与纸板材料与制品 非食品产品与包装检测实验室 PB-233/ICP wyd. II z dn. 15.11.2017","test_object_zh":"塑料材料与制品、纸与纸板材料与制品"},{"_id":"6a7d76396040ebab2620d403","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury","methodology":"Cu (50 – 500) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cu (50 – 500) mg/kg","reference":"PB-233/ICP wyd. II z dn. 15.11.2017","norm_bases":["PB-233/ICP wyd. II z dn. 15.11.2017"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury Cu (50 – 500) mg/kg PB-233/ICP wyd. II z dn. 15.11.2017 Materialy i wyroby z tworzyw sztucznych, Materialy i wyroby z papieru, tektury Cu (50 – 500) mg/kg PB-233/ICP wyd. II z dn. 15.11.2017","categories":["materials"],"row_index":396,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Cu (50 – 500) mg/kg","search_en":"Plastic materials and articles, Paper and board materials and articles Cu (50 – 500) mg/kg Non-Food Products and Packaging Testing Laboratory PB-233/ICP wyd. II z dn. 15.11.2017","test_object_en":"Plastic materials and articles, Paper and board materials and articles","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"塑料材料与制品、纸与纸板材料与制品 非食品产品与包装检测实验室 PB-233/ICP wyd. II z dn. 15.11.2017","test_object_zh":"塑料材料与制品、纸与纸板材料与制品"},{"_id":"6a7d76396040ebab2620d404","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury","methodology":"Pb (2,0 – 500) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pb (2,0 – 500) mg/kg","reference":"PB-233/ICP wyd. II z dn. 15.11.2017","norm_bases":["PB-233/ICP wyd. II z dn. 15.11.2017"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury Pb (2,0 – 500) mg/kg PB-233/ICP wyd. II z dn. 15.11.2017 Materialy i wyroby z tworzyw sztucznych, Materialy i wyroby z papieru, tektury Pb (2,0 – 500) mg/kg PB-233/ICP wyd. II z dn. 15.11.2017","categories":["materials"],"row_index":397,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Pb (2,0 – 500) mg/kg","search_en":"Plastic materials and articles, Paper and board materials and articles Pb (2,0 – 500) mg/kg Non-Food Products and Packaging Testing Laboratory PB-233/ICP wyd. II z dn. 15.11.2017","test_object_en":"Plastic materials and articles, Paper and board materials and articles","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"塑料材料与制品、纸与纸板材料与制品 非食品产品与包装检测实验室 PB-233/ICP wyd. II z dn. 15.11.2017","test_object_zh":"塑料材料与制品、纸与纸板材料与制品"},{"_id":"6a7d76396040ebab2620d405","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury","methodology":"Mn (50 – 500) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Mn (50 – 500) mg/kg","reference":"PB-233/ICP wyd. II z dn. 15.11.2017","norm_bases":["PB-233/ICP wyd. II z dn. 15.11.2017"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury Mn (50 – 500) mg/kg PB-233/ICP wyd. II z dn. 15.11.2017 Materialy i wyroby z tworzyw sztucznych, Materialy i wyroby z papieru, tektury Mn (50 – 500) mg/kg PB-233/ICP wyd. II z dn. 15.11.2017","categories":["materials"],"row_index":398,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Mn (50 – 500) mg/kg","search_en":"Plastic materials and articles, Paper and board materials and articles Mn (50 – 500) mg/kg Non-Food Products and Packaging Testing Laboratory PB-233/ICP wyd. II z dn. 15.11.2017","test_object_en":"Plastic materials and articles, Paper and board materials and articles","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"塑料材料与制品、纸与纸板材料与制品 非食品产品与包装检测实验室 PB-233/ICP wyd. II z dn. 15.11.2017","test_object_zh":"塑料材料与制品、纸与纸板材料与制品"},{"_id":"6a7d76396040ebab2620d406","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury","methodology":"Hg (0,5 – 50) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Hg (0,5 – 50) mg/kg","reference":"PB-233/ICP wyd. II z dn. 15.11.2017","norm_bases":["PB-233/ICP wyd. II z dn. 15.11.2017"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury Hg (0,5 – 50) mg/kg PB-233/ICP wyd. II z dn. 15.11.2017 Materialy i wyroby z tworzyw sztucznych, Materialy i wyroby z papieru, tektury Hg (0,5 – 50) mg/kg PB-233/ICP wyd. II z dn. 15.11.2017","categories":["materials"],"row_index":399,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Hg (0,5 – 50) mg/kg","search_en":"Plastic materials and articles, Paper and board materials and articles Hg (0,5 – 50) mg/kg Non-Food Products and Packaging Testing Laboratory PB-233/ICP wyd. II z dn. 15.11.2017","test_object_en":"Plastic materials and articles, Paper and board materials and articles","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"塑料材料与制品、纸与纸板材料与制品 非食品产品与包装检测实验室 PB-233/ICP wyd. II z dn. 15.11.2017","test_object_zh":"塑料材料与制品、纸与纸板材料与制品"},{"_id":"6a7d76396040ebab2620d407","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury","methodology":"Ni (5,0 – 500) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ni (5,0 – 500) mg/kg","reference":"PB-233/ICP wyd. II z dn. 15.11.2017","norm_bases":["PB-233/ICP wyd. II z dn. 15.11.2017"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury Ni (5,0 – 500) mg/kg PB-233/ICP wyd. II z dn. 15.11.2017 Materialy i wyroby z tworzyw sztucznych, Materialy i wyroby z papieru, tektury Ni (5,0 – 500) mg/kg PB-233/ICP wyd. II z dn. 15.11.2017","categories":["materials"],"row_index":400,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Ni (5,0 – 500) mg/kg","search_en":"Plastic materials and articles, Paper and board materials and articles Ni (5,0 – 500) mg/kg Non-Food Products and Packaging Testing Laboratory PB-233/ICP wyd. II z dn. 15.11.2017","test_object_en":"Plastic materials and articles, Paper and board materials and articles","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"塑料材料与制品、纸与纸板材料与制品 非食品产品与包装检测实验室 PB-233/ICP wyd. II z dn. 15.11.2017","test_object_zh":"塑料材料与制品、纸与纸板材料与制品"},{"_id":"6a7d76396040ebab2620d408","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury","methodology":"Se (5,0 – 500) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Se (5,0 – 500) mg/kg","reference":"PB-233/ICP wyd. II z dn. 15.11.2017","norm_bases":["PB-233/ICP wyd. II z dn. 15.11.2017"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury Se (5,0 – 500) mg/kg PB-233/ICP wyd. II z dn. 15.11.2017 Materialy i wyroby z tworzyw sztucznych, Materialy i wyroby z papieru, tektury Se (5,0 – 500) mg/kg PB-233/ICP wyd. II z dn. 15.11.2017","categories":["materials"],"row_index":401,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Se (5,0 – 500) mg/kg","search_en":"Plastic materials and articles, Paper and board materials and articles Se (5,0 – 500) mg/kg Non-Food Products and Packaging Testing Laboratory PB-233/ICP wyd. II z dn. 15.11.2017","test_object_en":"Plastic materials and articles, Paper and board materials and articles","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"塑料材料与制品、纸与纸板材料与制品 非食品产品与包装检测实验室 PB-233/ICP wyd. II z dn. 15.11.2017","test_object_zh":"塑料材料与制品、纸与纸板材料与制品"},{"_id":"6a7d76396040ebab2620d409","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury","methodology":"Sr (50 – 500) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Sr (50 – 500) mg/kg","reference":"PB-233/ICP wyd. II z dn. 15.11.2017","norm_bases":["PB-233/ICP wyd. II z dn. 15.11.2017"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury Sr (50 – 500) mg/kg PB-233/ICP wyd. II z dn. 15.11.2017 Materialy i wyroby z tworzyw sztucznych, Materialy i wyroby z papieru, tektury Sr (50 – 500) mg/kg PB-233/ICP wyd. II z dn. 15.11.2017","categories":["materials"],"row_index":402,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Sr (50 – 500) mg/kg","search_en":"Plastic materials and articles, Paper and board materials and articles Sr (50 – 500) mg/kg Non-Food Products and Packaging Testing Laboratory PB-233/ICP wyd. II z dn. 15.11.2017","test_object_en":"Plastic materials and articles, Paper and board materials and articles","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"塑料材料与制品、纸与纸板材料与制品 非食品产品与包装检测实验室 PB-233/ICP wyd. II z dn. 15.11.2017","test_object_zh":"塑料材料与制品、纸与纸板材料与制品"},{"_id":"6a7d76396040ebab2620d40a","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury","methodology":"Sn (ogólna) (50 – 500) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Sn (ogólna) (50 – 500) mg/kg","reference":"PB-233/ICP wyd. II z dn. 15.11.2017","norm_bases":["PB-233/ICP wyd. II z dn. 15.11.2017"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury Sn (ogólna) (50 – 500) mg/kg PB-233/ICP wyd. II z dn. 15.11.2017 Materialy i wyroby z tworzyw sztucznych, Materialy i wyroby z papieru, tektury Sn (ogolna) (50 – 500) mg/kg PB-233/ICP wyd. II z dn. 15.11.2017","categories":["materials"],"row_index":403,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Sn (total) (50 – 500) mg/kg","search_en":"Plastic materials and articles, Paper and board materials and articles Sn (total) (50 – 500) mg/kg Non-Food Products and Packaging Testing Laboratory PB-233/ICP wyd. II z dn. 15.11.2017","test_object_en":"Plastic materials and articles, Paper and board materials and articles","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"塑料材料与制品、纸与纸板材料与制品 非食品产品与包装检测实验室 PB-233/ICP wyd. II z dn. 15.11.2017","test_object_zh":"塑料材料与制品、纸与纸板材料与制品"},{"_id":"6a7d76396040ebab2620d40b","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury","methodology":"Zn (50 – 500) mg/kg","parameters":[],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Zn (50 – 500) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PB-233/ICP wyd. II z dn. 15.11.2017","norm_bases":["PB-233/ICP wyd. II z dn. 15.11.2017"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych, Materiały i wyroby z papieru, tektury Zn (50 – 500) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PB-233/ICP wyd. II z dn. 15.11.2017 Materialy i wyroby z tworzyw sztucznych, Materialy i wyroby z papieru, tektury Zn (50 – 500) mg/kg\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PB-233/ICP wyd. II z dn. 15.11.2017","categories":["materials"],"row_index":404,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Zn (50 – 500) mg/kg","search_en":"Plastic materials and articles, Paper and board materials and articles Zn (50 – 500) mg/kg Inductively coupled plasma mass spectrometry (ICP-MS) Non-Food Products and Packaging Testing Laboratory PB-233/ICP wyd. II z dn. 15.11.2017","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Plastic materials and articles, Paper and board materials and articles","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"塑料材料与制品、纸与纸板材料与制品 电感耦合等离子体质谱法（ICP-MS） 非食品产品与包装检测实验室 PB-233/ICP wyd. II z dn. 15.11.2017","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"塑料材料与制品、纸与纸板材料与制品"},{"_id":"6a7d76396040ebab2620d40c","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych, materiały wielowarstwowe, folie wiskozowe","methodology":"Przenikalność tlenu","parameters":[{"name":"Zakres","range":"(0,005 – 2000) cm3/(m2·24h)"}],"technique":"Metoda czujnika kulometrycznego","techniques":["Metoda czujnika kulometrycznego"],"computed":[],"activity":"Przenikalność tlenu\nZakres (0,005 – 2000) cm3/(m2·24h)\nMetoda czujnika kulometrycznego","reference":"ASTM D 3985-24","norm_bases":["ASTM D 3985-24"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych, materiały wielowarstwowe, folie wiskozowe Przenikalność tlenu\nZakres (0,005 – 2000) cm3/(m2·24h)\nMetoda czujnika kulometrycznego ASTM D 3985-24 Materialy i wyroby z tworzyw sztucznych, materialy wielowarstwowe, folie wiskozowe Przenikalnosc tlenu\nZakres (0,005 – 2000) cm3/(m2·24h)\nMetoda czujnika kulometrycznego ASTM D 3985-24","categories":["materials"],"row_index":405,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Oxygen permeability","parameters_en":[{"name":"Range","range":"(0,005 – 2000) cm3/(m2·24h)"}],"search_en":"Plastic materials and articles, multilayer materials, viscose films Oxygen permeability Coulometric sensor method Non-Food Products and Packaging Testing Laboratory Range ASTM D 3985-24","technique_en":"Coulometric sensor method","test_object_en":"Plastic materials and articles, multilayer materials, viscose films","lab_section_zh":"非食品产品与包装检测实验室","parameters_zh":[{"name":"范围","range":"(0,005 – 2000) cm3/(m2·24h)"}],"search_zh":"塑料材料与制品、多层材料、粘胶薄膜 透氧性 库仑传感器法 非食品产品与包装检测实验室 范围 ASTM D 3985-24","methodology_zh":"透氧性","technique_zh":"库仑传感器法","test_object_zh":"塑料材料与制品、多层材料、粘胶薄膜"},{"_id":"6a7d76396040ebab2620d40d","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych, materiały wielowarstwowe, folie wiskozowe","methodology":"Przenikalność tlenu","parameters":[{"name":"Zakres","range":"(0,005 – 2000) cm3/(m2·24/h)"}],"technique":"Metoda czujnika kulometrycznego","techniques":["Metoda czujnika kulometrycznego"],"computed":[],"activity":"Przenikalność tlenu\nZakres (0,005 – 2000) cm3/(m2·24/h)\nMetoda czujnika kulometrycznego","reference":"ASTM F 1927-20","norm_bases":["ASTM F 1927-20"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych, materiały wielowarstwowe, folie wiskozowe Przenikalność tlenu\nZakres (0,005 – 2000) cm3/(m2·24/h)\nMetoda czujnika kulometrycznego ASTM F 1927-20 Materialy i wyroby z tworzyw sztucznych, materialy wielowarstwowe, folie wiskozowe Przenikalnosc tlenu\nZakres (0,005 – 2000) cm3/(m2·24/h)\nMetoda czujnika kulometrycznego ASTM F 1927-20","categories":["materials"],"row_index":406,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Oxygen permeability","parameters_en":[{"name":"Range","range":"(0,005 – 2000) cm3/(m2·24/h)"}],"search_en":"Plastic materials and articles, multilayer materials, viscose films Oxygen permeability Coulometric sensor method Non-Food Products and Packaging Testing Laboratory Range ASTM F 1927-20","technique_en":"Coulometric sensor method","test_object_en":"Plastic materials and articles, multilayer materials, viscose films","lab_section_zh":"非食品产品与包装检测实验室","parameters_zh":[{"name":"范围","range":"(0,005 – 2000) cm3/(m2·24/h)"}],"search_zh":"塑料材料与制品、多层材料、粘胶薄膜 透氧性 库仑传感器法 非食品产品与包装检测实验室 范围 ASTM F 1927-20","methodology_zh":"透氧性","technique_zh":"库仑传感器法","test_object_zh":"塑料材料与制品、多层材料、粘胶薄膜"},{"_id":"6a7d76396040ebab2620d40e","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych, materiały wielowarstwowe, folie wiskozowe","methodology":"Przenikalność pary wodnej","parameters":[{"name":"Zakres","range":"(0,005 – 1000) g/(m2·24h)"}],"technique":"Metoda czujnika podczerwieni","techniques":["Metoda czujnika podczerwieni"],"computed":[],"activity":"Przenikalność pary wodnej\nZakres (0,005 – 1000) g/(m2·24h)\nMetoda czujnika podczerwieni","reference":"ASTM F 1249-25","norm_bases":["ASTM F 1249-25"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych, materiały wielowarstwowe, folie wiskozowe Przenikalność pary wodnej\nZakres (0,005 – 1000) g/(m2·24h)\nMetoda czujnika podczerwieni ASTM F 1249-25 Materialy i wyroby z tworzyw sztucznych, materialy wielowarstwowe, folie wiskozowe Przenikalnosc pary wodnej\nZakres (0,005 – 1000) g/(m2·24h)\nMetoda czujnika podczerwieni ASTM F 1249-25","categories":["materials"],"row_index":407,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Water vapour permeability","parameters_en":[{"name":"Range","range":"(0,005 – 1000) g/(m2·24h)"}],"search_en":"Plastic materials and articles, multilayer materials, viscose films Water vapour permeability Infrared sensor method Non-Food Products and Packaging Testing Laboratory Range ASTM F 1249-25","technique_en":"Infrared sensor method","test_object_en":"Plastic materials and articles, multilayer materials, viscose films","lab_section_zh":"非食品产品与包装检测实验室","parameters_zh":[{"name":"范围","range":"(0,005 – 1000) g/(m2·24h)"}],"search_zh":"塑料材料与制品、多层材料、粘胶薄膜 红外传感器法 非食品产品与包装检测实验室 范围 ASTM F 1249-25","technique_zh":"红外传感器法","test_object_zh":"塑料材料与制品、多层材料、粘胶薄膜"},{"_id":"6a7d76396040ebab2620d40f","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych: jednowarstwowe, wielowarstwowe, jednowarstwowe z nadrukiem, wielowarstwowe z nadrukiem, Materiały i wyroby z papieru, tektury","methodology":"Screening substancji dodanych w sposób niezamierzony (NIAS), zawartość w płynach modelowych imitujących żywność: MPPO (Tenax), 95","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Screening substancji dodanych w sposób niezamierzony (NIAS), zawartość w płynach modelowych imitujących żywność: MPPO (Tenax), 95","reference":"PB-502 wyd. 3 z dn. 30.10.2023","norm_bases":["PB-502 wyd. 3 z dn. 30.10.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych: jednowarstwowe, wielowarstwowe, jednowarstwowe z nadrukiem, wielowarstwowe z nadrukiem, Materiały i wyroby z papieru, tektury Screening substancji dodanych w sposób niezamierzony (NIAS), zawartość w płynach modelowych imitujących żywność: MPPO (Tenax), 95 PB-502 wyd. 3 z dn. 30.10.2023 Materialy i wyroby z tworzyw sztucznych: jednowarstwowe, wielowarstwowe, jednowarstwowe z nadrukiem, wielowarstwowe z nadrukiem, Materialy i wyroby z papieru, tektury Screening substancji dodanych w sposob niezamierzony (NIAS), zawartosc w plynach modelowych imitujacych zywnosc: MPPO (Tenax), 95 PB-502 wyd. 3 z dn. 30.10.2023","categories":["materials","food"],"row_index":408,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Screening of non-intentionally added substances (NIAS), content in food simulants: MPPO (Tenax), 95","search_en":"Plastic materials and articles: single-layer, multilayer, single-layer printed, multilayer printed, Materials and articles made of paper, cardboard Screening of non-intentionally added substances (NIAS), content in food simulants: MPPO (Tenax), 95 Non-Food Products and Packaging Testing Laboratory PB-502 wyd. 3 z dn. 30.10.2023","test_object_en":"Plastic materials and articles: single-layer, multilayer, single-layer printed, multilayer printed, Materials and articles made of paper, cardboard","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"非食品产品与包装检测实验室 PB-502 wyd. 3 z dn. 30.10.2023"},{"_id":"6a7d76396040ebab2620d410","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych: jednowarstwowe, wielowarstwowe, jednowarstwowe z nadrukiem, wielowarstwowe z nadrukiem, Materiały i wyroby z papieru, tektury","methodology":"% etanol, 50 % etanol, 20 % etanol, 10 % etanol, 3 % kwas octowy","parameters":[{"name":"Zakres","range":"(0,01 – 60) mg/kg"}],"technique":"Metoda chromatografii cieczowej z detekcją spektrometrią mas i czasem przelotu (LC-QTOF-MS)","techniques":["Metoda chromatografii cieczowej z detekcją spektrometrią mas i czasem przelotu (LC-QTOF-MS)"],"computed":[],"activity":"% etanol, 50 % etanol, 20 % etanol, 10 % etanol, 3 % kwas octowy\nZakres (0,01 – 60) mg/kg\nMetoda chromatografii cieczowej z detekcją spektrometrią mas i czasem przelotu (LC-QTOF-MS)","reference":"PB-502 wyd. 3 z dn. 30.10.2023","norm_bases":["PB-502 wyd. 3 z dn. 30.10.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych: jednowarstwowe, wielowarstwowe, jednowarstwowe z nadrukiem, wielowarstwowe z nadrukiem, Materiały i wyroby z papieru, tektury % etanol, 50 % etanol, 20 % etanol, 10 % etanol, 3 % kwas octowy\nZakres (0,01 – 60) mg/kg\nMetoda chromatografii cieczowej z detekcją spektrometrią mas i czasem przelotu (LC-QTOF-MS) PB-502 wyd. 3 z dn. 30.10.2023 Materialy i wyroby z tworzyw sztucznych: jednowarstwowe, wielowarstwowe, jednowarstwowe z nadrukiem, wielowarstwowe z nadrukiem, Materialy i wyroby z papieru, tektury % etanol, 50 % etanol, 20 % etanol, 10 % etanol, 3 % kwas octowy\nZakres (0,01 – 60) mg/kg\nMetoda chromatografii cieczowej z detekcja spektrometria mas i czasem przelotu (LC-QTOF-MS) PB-502 wyd. 3 z dn. 30.10.2023","categories":["materials"],"row_index":409,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"% ethanol, 50 % ethanol, 20 % ethanol, 10 % ethanol, 3 % acetic acid","parameters_en":[{"name":"Range","range":"(0,01 – 60) mg/kg"}],"search_en":"Plastic materials and articles: single-layer, multilayer, single-layer printed, multilayer printed, Materials and articles made of paper, cardboard % ethanol, 50 % ethanol, 20 % ethanol, 10 % ethanol, 3 % acetic acid Liquid chromatography with quadrupole time-of-flight mass spectrometry detection (LC-QTOF-MS) Non-Food Products and Packaging Testing Laboratory Range PB-502 wyd. 3 z dn. 30.10.2023","technique_en":"Liquid chromatography with quadrupole time-of-flight mass spectrometry detection (LC-QTOF-MS)","test_object_en":"Plastic materials and articles: single-layer, multilayer, single-layer printed, multilayer printed, Materials and articles made of paper, cardboard","lab_section_zh":"非食品产品与包装检测实验室","parameters_zh":[{"name":"范围","range":"(0,01 – 60) mg/kg"}],"search_zh":"非食品产品与包装检测实验室 范围 PB-502 wyd. 3 z dn. 30.10.2023"},{"_id":"6a7d76396040ebab2620d411","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z papieru, tektury oraz ich wyciągi wodne","methodology":"Zawartość glioksalu","parameters":[{"name":"Zakres","range":"(12 – 190) mg/kg"},{"name":"Zakres","range":"(0,0019 – 1,9) mg/dm2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość glioksalu\nZakres:\nZakres (12 – 190) mg/kg\nZakres (0,0019 – 1,9) mg/dm2\nMetoda spektrofotometryczna","reference":"DIN 54603:2008-08","norm_bases":["DIN 54603:2008-08"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z papieru, tektury oraz ich wyciągi wodne Zawartość glioksalu\nZakres:\nZakres (12 – 190) mg/kg\nZakres (0,0019 – 1,9) mg/dm2\nMetoda spektrofotometryczna DIN 54603:2008-08 Materialy i wyroby z papieru, tektury oraz ich wyciagi wodne Zawartosc glioksalu\nZakres:\nZakres (12 – 190) mg/kg\nZakres (0,0019 – 1,9) mg/dm2\nMetoda spektrofotometryczna DIN 54603:2008-08","categories":["materials"],"row_index":410,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Glyoxal content","parameters_en":[{"name":"Range","range":"(12 – 190) mg/kg"},{"name":"Range","range":"(0,0019 – 1,9) mg/dm2"}],"search_en":"Materials and articles of paper and paperboard and their water extracts Glyoxal content Spectrophotometric method Non-Food Products and Packaging Testing Laboratory Range Range DIN 54603:2008-08","technique_en":"Spectrophotometric method","test_object_en":"Materials and articles of paper and paperboard and their water extracts","lab_section_zh":"非食品产品与包装检测实验室","parameters_zh":[{"name":"范围","range":"(12 – 190) mg/kg"},{"name":"范围","range":"(0,0019 – 1,9) mg/dm2"}],"search_zh":"纸与纸板材料及制品及其水浸出液 分光光度法 非食品产品与包装检测实验室 范围 范围 DIN 54603:2008-08","technique_zh":"分光光度法","test_object_zh":"纸与纸板材料及制品及其水浸出液"},{"_id":"6a7d76396040ebab2620d412","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z papieru, tektury oraz ich wyciągi wodne","methodology":"Zawartość pochodnych epichlorohydryny","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość pochodnych epichlorohydryny","reference":"PB-572 wyd 1 z dn. 29.08.2023","norm_bases":["PB-572 wyd 1 z dn. 29.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z papieru, tektury oraz ich wyciągi wodne Zawartość pochodnych epichlorohydryny PB-572 wyd 1 z dn. 29.08.2023 Materialy i wyroby z papieru, tektury oraz ich wyciagi wodne Zawartosc pochodnych epichlorohydryny PB-572 wyd 1 z dn. 29.08.2023","categories":["materials"],"row_index":411,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Content of epichlorohydrin derivatives","search_en":"Materials and articles of paper and paperboard and their water extracts Content of epichlorohydrin derivatives Non-Food Products and Packaging Testing Laboratory PB-572 wyd 1 z dn. 29.08.2023","test_object_en":"Materials and articles of paper and paperboard and their water extracts","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"纸与纸板材料及制品及其水浸出液 非食品产品与包装检测实验室 PB-572 wyd 1 z dn. 29.08.2023","test_object_zh":"纸与纸板材料及制品及其水浸出液"},{"_id":"6a7d76396040ebab2620d413","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z papieru, tektury oraz ich wyciągi wodne","methodology":"1,3-dichloro-2-propanol (1,3-DCP) (1,0 – 25) μg/l","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"1,3-dichloro-2-propanol (1,3-DCP) (1,0 – 25) μg/l","reference":"PB-572 wyd 1 z dn. 29.08.2023","norm_bases":["PB-572 wyd 1 z dn. 29.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z papieru, tektury oraz ich wyciągi wodne 1,3-dichloro-2-propanol (1,3-DCP) (1,0 – 25) μg/l PB-572 wyd 1 z dn. 29.08.2023 Materialy i wyroby z papieru, tektury oraz ich wyciagi wodne 1,3-dichloro-2-propanol (1,3-DCP) (1,0 – 25) μg/l PB-572 wyd 1 z dn. 29.08.2023","categories":["materials"],"row_index":412,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"1,3-dichloro-2-propanol (1,3-DCP) (1,0 – 25) μg/l","search_en":"Materials and articles of paper and paperboard and their water extracts 1,3-dichloro-2-propanol (1,3-DCP) (1,0 – 25) μg/l Non-Food Products and Packaging Testing Laboratory PB-572 wyd 1 z dn. 29.08.2023","test_object_en":"Materials and articles of paper and paperboard and their water extracts","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"纸与纸板材料及制品及其水浸出液 非食品产品与包装检测实验室 PB-572 wyd 1 z dn. 29.08.2023","test_object_zh":"纸与纸板材料及制品及其水浸出液"},{"_id":"6a7d76396040ebab2620d414","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z papieru, tektury oraz ich wyciągi wodne","methodology":"3-monochloro-1,2-propanodiol (3-MCPD) (5,0 – 70) μg/l","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) cechy/metoda","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) cechy/metoda"],"computed":[],"activity":"3-monochloro-1,2-propanodiol (3-MCPD) (5,0 – 70) μg/l\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) cechy/metoda","reference":"PB-572 wyd 1 z dn. 29.08.2023","norm_bases":["PB-572 wyd 1 z dn. 29.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z papieru, tektury oraz ich wyciągi wodne 3-monochloro-1,2-propanodiol (3-MCPD) (5,0 – 70) μg/l\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) cechy/metoda PB-572 wyd 1 z dn. 29.08.2023 Materialy i wyroby z papieru, tektury oraz ich wyciagi wodne 3-monochloro-1,2-propanodiol (3-MCPD) (5,0 – 70) μg/l\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) cechy/metoda PB-572 wyd 1 z dn. 29.08.2023","categories":["materials"],"row_index":413,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"3-monochloro-1,2-propanediol (3-MCPD) (5,0 – 70) μg/l","search_en":"Materials and articles of paper and paperboard and their water extracts 3-monochloro-1,2-propanediol (3-MCPD) (5,0 – 70) μg/l Gas chromatography with mass spectrometry detection (GC-MS) characteristics/method Non-Food Products and Packaging Testing Laboratory PB-572 wyd 1 z dn. 29.08.2023","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS) characteristics/method","test_object_en":"Materials and articles of paper and paperboard and their water extracts","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"纸与纸板材料及制品及其水浸出液 非食品产品与包装检测实验室 PB-572 wyd 1 z dn. 29.08.2023","test_object_zh":"纸与纸板材料及制品及其水浸出液"},{"_id":"6a7d76396040ebab2620d415","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Uwalnianie pierwiastków do płynu modelowego – kwas cytrynowy 0,5%","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Uwalnianie pierwiastków do płynu modelowego – kwas cytrynowy 0,5%","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Uwalnianie pierwiastków do płynu modelowego – kwas cytrynowy 0,5% PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Uwalnianie pierwiastkow do plynu modelowego – kwas cytrynowy 0,5% PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":414,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Release of elements into the model liquid – citric acid 0,5%","search_en":"Metal materials and products Release of elements into the model liquid – citric acid 0,5% Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d416","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Mg (0,050 – 1000) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Mg (0,050 – 1000) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Mg (0,050 – 1000) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Mg (0,050 – 1000) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":415,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Mg (0,050 – 1000) mg/kg","search_en":"Metal materials and products Mg (0,050 – 1000) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d417","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Al (0,050 – 200) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Al (0,050 – 200) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Al (0,050 – 200) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Al (0,050 – 200) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":416,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Al (0,050 – 200) mg/kg","search_en":"Metal materials and products Al (0,050 – 200) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d418","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Sb (0,005 – 10) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Sb (0,005 – 10) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Sb (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Sb (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":417,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Sb (0,005 – 10) mg/kg","search_en":"Metal materials and products Sb (0,005 – 10) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d419","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Co (0,005 – 10) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Co (0,005 – 10) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Co (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Co (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":418,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Co (0,005 – 10) mg/kg","search_en":"Metal materials and products Co (0,005 – 10) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d41a","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Mo (0,005 – 10) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Mo (0,005 – 10) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Mo (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Mo (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":419,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Mo (0,005 – 10) mg/kg","search_en":"Metal materials and products Mo (0,005 – 10) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d41b","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Cr (0,050 – 100) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cr (0,050 – 100) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Cr (0,050 – 100) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Cr (0,050 – 100) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":420,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Cr (0,050 – 100) mg/kg","search_en":"Metal materials and products Cr (0,050 – 100) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d41c","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Mn (0,050 – 100) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Mn (0,050 – 100) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Mn (0,050 – 100) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Mn (0,050 – 100) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":421,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Mn (0,050 – 100) mg/kg","search_en":"Metal materials and products Mn (0,050 – 100) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d41d","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Fe (0,050 – 500) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Fe (0,050 – 500) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Fe (0,050 – 500) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Fe (0,050 – 500) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":422,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Fe (0,050 – 500) mg/kg","search_en":"Metal materials and products Fe (0,050 – 500) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d41e","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Ni (0,005 – 10) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ni (0,005 – 10) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Ni (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Ni (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":423,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Ni (0,005 – 10) mg/kg","search_en":"Metal materials and products Ni (0,005 – 10) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d41f","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Cu (0,005 – 10) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cu (0,005 – 10) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Cu (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Cu (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":424,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Cu (0,005 – 10) mg/kg","search_en":"Metal materials and products Cu (0,005 – 10) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d420","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Zn (0,050 – 100) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zn (0,050 – 100) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Zn (0,050 – 100) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Zn (0,050 – 100) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":425,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Zn (0,050 – 100) mg/kg","search_en":"Metal materials and products Zn (0,050 – 100) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d421","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Ag (0,005 – 10) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ag (0,005 – 10) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Ag (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Ag (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":426,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Ag (0,005 – 10) mg/kg","search_en":"Metal materials and products Ag (0,005 – 10) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d422","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Sn (0,050 – 1000) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Sn (0,050 – 1000) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Sn (0,050 – 1000) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Sn (0,050 – 1000) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":427,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Sn (0,050 – 1000) mg/kg","search_en":"Metal materials and products Sn (0,050 – 1000) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d423","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Ti (0,005 – 10) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ti (0,005 – 10) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Ti (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Ti (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":428,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Ti (0,005 – 10) mg/kg","search_en":"Metal materials and products Ti (0,005 – 10) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d424","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"V (0,001 – 10) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"V (0,001 – 10) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe V (0,001 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe V (0,001 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":429,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"V (0,001 – 10) mg/kg","search_en":"Metal materials and products V (0,001 – 10) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d425","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Ba (0,050 – 100) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ba (0,050 – 100) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Ba (0,050 – 100) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Ba (0,050 – 100) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":430,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Ba (0,050 – 100) mg/kg","search_en":"Metal materials and products Ba (0,050 – 100) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d426","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Be (0,001 – 10) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Be (0,001 – 10) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Be (0,001 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Be (0,001 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":431,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Be (0,001 – 10) mg/kg","search_en":"Metal materials and products Be (0,001 – 10) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d427","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Pb (0,005 – 10) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pb (0,005 – 10) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Pb (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Pb (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":432,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Pb (0,005 – 10) mg/kg","search_en":"Metal materials and products Pb (0,005 – 10) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d428","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Li (0,005 – 10) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Li (0,005 – 10) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Li (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Li (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":433,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Li (0,005 – 10) mg/kg","search_en":"Metal materials and products Li (0,005 – 10) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d429","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Hg (0,001 – 0,005) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Hg (0,001 – 0,005) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Hg (0,001 – 0,005) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Hg (0,001 – 0,005) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":434,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Hg (0,001 – 0,005) mg/kg","search_en":"Metal materials and products Hg (0,001 – 0,005) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d42a","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Tl (0,001 – 1,0) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Tl (0,001 – 1,0) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Tl (0,001 – 1,0) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Tl (0,001 – 1,0) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":435,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Tl (0,001 – 1,0) mg/kg","search_en":"Metal materials and products Tl (0,001 – 1,0) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d42b","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"As (0,001 – 10) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"As (0,001 – 10) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe As (0,001 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe As (0,001 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":436,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"As (0,001 – 10) mg/kg","search_en":"Metal materials and products As (0,001 – 10) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d42c","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Cd (0,001 – 10) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cd (0,001 – 10) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Cd (0,001 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Cd (0,001 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":437,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Cd (0,001 – 10) mg/kg","search_en":"Metal materials and products Cd (0,001 – 10) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d42d","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Zr (0,050 – 100) mg/kg","parameters":[],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Zr (0,050 – 100) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Zr (0,050 – 100) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Zr (0,050 – 100) mg/kg\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":438,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Zr (0,050 – 100) mg/kg","search_en":"Metal materials and products Zr (0,050 – 100) mg/kg Inductively coupled plasma mass spectrometry (ICP-MS) Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 电感耦合等离子体质谱法（ICP-MS） 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d42e","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Uwalnianie pierwiastków do płynu modelowego – woda (EN 16889)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Uwalnianie pierwiastków do płynu modelowego – woda (EN 16889)","reference":"PB-298 wyd. 2 z dn. 07.08.2023 | EN 16889","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023","EN 16889"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Uwalnianie pierwiastków do płynu modelowego – woda (EN 16889) PB-298 wyd. 2 z dn. 07.08.2023 | EN 16889 Materialy i wyroby metalowe Uwalnianie pierwiastkow do plynu modelowego – woda (EN 16889) PB-298 wyd. 2 z dn. 07.08.2023 | EN 16889","categories":["materials","water"],"row_index":439,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Release of elements into the model liquid – water (EN 16889)","search_en":"Metal materials and products Release of elements into the model liquid – water (EN 16889) Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023 | EN 16889","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023 | EN 16889","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d42f","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Al (0,050 – 200) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Al (0,050 – 200) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Al (0,050 – 200) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Al (0,050 – 200) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":440,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Al (0,050 – 200) mg/kg","search_en":"Metal materials and products Al (0,050 – 200) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d430","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Sb (0,005 – 10) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Sb (0,005 – 10) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Sb (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Sb (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":441,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Sb (0,005 – 10) mg/kg","search_en":"Metal materials and products Sb (0,005 – 10) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d431","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Co (0,005 – 10) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Co (0,005 – 10) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Co (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Co (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":442,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Co (0,005 – 10) mg/kg","search_en":"Metal materials and products Co (0,005 – 10) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d432","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Mo (0,005 – 10) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Mo (0,005 – 10) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Mo (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Mo (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":443,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Mo (0,005 – 10) mg/kg","search_en":"Metal materials and products Mo (0,005 – 10) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d433","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Cr (0,050 – 100) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cr (0,050 – 100) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Cr (0,050 – 100) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Cr (0,050 – 100) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":444,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Cr (0,050 – 100) mg/kg","search_en":"Metal materials and products Cr (0,050 – 100) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d434","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Mn (0,050 – 100) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Mn (0,050 – 100) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Mn (0,050 – 100) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Mn (0,050 – 100) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":445,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Mn (0,050 – 100) mg/kg","search_en":"Metal materials and products Mn (0,050 – 100) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d435","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Fe (0,050 – 500) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Fe (0,050 – 500) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Fe (0,050 – 500) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Fe (0,050 – 500) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":446,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Fe (0,050 – 500) mg/kg","search_en":"Metal materials and products Fe (0,050 – 500) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d436","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Ni (0,005 – 10) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ni (0,005 – 10) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Ni (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Ni (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":447,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Ni (0,005 – 10) mg/kg","search_en":"Metal materials and products Ni (0,005 – 10) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d437","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Cu (0,005 – 10) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cu (0,005 – 10) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Cu (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Cu (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":448,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Cu (0,005 – 10) mg/kg","search_en":"Metal materials and products Cu (0,005 – 10) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d438","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Zn (0,050 – 100) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zn (0,050 – 100) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Zn (0,050 – 100) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Zn (0,050 – 100) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":449,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Zn (0,050 – 100) mg/kg","search_en":"Metal materials and products Zn (0,050 – 100) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d439","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Ag (0,005 – 10) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ag (0,005 – 10) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Ag (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Ag (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":450,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Ag (0,005 – 10) mg/kg","search_en":"Metal materials and products Ag (0,005 – 10) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d43a","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Sn (0,050 – 1000) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Sn (0,050 – 1000) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Sn (0,050 – 1000) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Sn (0,050 – 1000) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":451,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Sn (0,050 – 1000) mg/kg","search_en":"Metal materials and products Sn (0,050 – 1000) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d43b","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Ti (0,005 – 10) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ti (0,005 – 10) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Ti (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Ti (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":452,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Ti (0,005 – 10) mg/kg","search_en":"Metal materials and products Ti (0,005 – 10) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d43c","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"V (0,001 – 10) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"V (0,001 – 10) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe V (0,001 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe V (0,001 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":453,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"V (0,001 – 10) mg/kg","search_en":"Metal materials and products V (0,001 – 10) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d43d","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Ba (0,050 – 100) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ba (0,050 – 100) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Ba (0,050 – 100) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Ba (0,050 – 100) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":454,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Ba (0,050 – 100) mg/kg","search_en":"Metal materials and products Ba (0,050 – 100) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d43e","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Be (0,001 – 10) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Be (0,001 – 10) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Be (0,001 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Be (0,001 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":455,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Be (0,001 – 10) mg/kg","search_en":"Metal materials and products Be (0,001 – 10) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d43f","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Pb (0,005 – 10) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pb (0,005 – 10) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Pb (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Pb (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":456,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Pb (0,005 – 10) mg/kg","search_en":"Metal materials and products Pb (0,005 – 10) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d440","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Li (0,005 – 10) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Li (0,005 – 10) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Li (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Li (0,005 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":457,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Li (0,005 – 10) mg/kg","search_en":"Metal materials and products Li (0,005 – 10) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d441","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Hg (0,001 – 0,005) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Hg (0,001 – 0,005) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Hg (0,001 – 0,005) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Hg (0,001 – 0,005) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":458,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Hg (0,001 – 0,005) mg/kg","search_en":"Metal materials and products Hg (0,001 – 0,005) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d442","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Tl (0,001 – 1,0) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Tl (0,001 – 1,0) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Tl (0,001 – 1,0) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Tl (0,001 – 1,0) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":459,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Tl (0,001 – 1,0) mg/kg","search_en":"Metal materials and products Tl (0,001 – 1,0) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d443","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"As (0,001 – 10) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"As (0,001 – 10) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe As (0,001 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe As (0,001 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":460,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"As (0,001 – 10) mg/kg","search_en":"Metal materials and products As (0,001 – 10) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d444","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Cd (0,001 – 10) mg/kg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cd (0,001 – 10) mg/kg","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Cd (0,001 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Cd (0,001 – 10) mg/kg PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":461,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Cd (0,001 – 10) mg/kg","search_en":"Metal materials and products Cd (0,001 – 10) mg/kg Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d445","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby metalowe","methodology":"Zr (0,050 – 100) mg/kg","parameters":[],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) cechy/metoda","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) cechy/metoda"],"computed":[],"activity":"Zr (0,050 – 100) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) cechy/metoda","reference":"PB-298 wyd. 2 z dn. 07.08.2023","norm_bases":["PB-298 wyd. 2 z dn. 07.08.2023"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby metalowe Zr (0,050 – 100) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) cechy/metoda PB-298 wyd. 2 z dn. 07.08.2023 Materialy i wyroby metalowe Zr (0,050 – 100) mg/kg\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) cechy/metoda PB-298 wyd. 2 z dn. 07.08.2023","categories":["materials"],"row_index":462,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Zr (0,050 – 100) mg/kg","search_en":"Metal materials and products Zr (0,050 – 100) mg/kg Inductively coupled plasma mass spectrometry method (ICP-MS) characteristics/method Non-Food Products and Packaging Testing Laboratory PB-298 wyd. 2 z dn. 07.08.2023","technique_en":"Inductively coupled plasma mass spectrometry method (ICP-MS) characteristics/method","test_object_en":"Metal materials and products","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"金属材料与制品 非食品产品与包装检测实验室 PB-298 wyd. 2 z dn. 07.08.2023","test_object_zh":"金属材料与制品"},{"_id":"6a7d76396040ebab2620d446","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby do kontaktu z","methodology":"Zawartość alkilofenoli","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość alkilofenoli","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby do kontaktu z Zawartość alkilofenoli Normy Procedury badawcze Materialy i wyroby do kontaktu z Zawartosc alkilofenoli Normy Procedury badawcze","categories":["materials"],"row_index":463,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Alkylphenol content","search_en":"Materiały i wyroby do kontaktu z Alkylphenol content Non-Food Products and Packaging Testing Laboratory Normy Procedury badawcze","test_object_en":"Materiały i wyroby do kontaktu z","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"非食品产品与包装检测实验室 Normy Procedury badawcze"},{"_id":"6a7d76396040ebab2620d447","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"żywnością i inne materiały i wyroby","methodology":"","parameters":[],"technique":"Metoda wysokosprawnej","techniques":["Metoda wysokosprawnej"],"computed":[],"activity":"Metoda wysokosprawnej","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"żywnością i inne materiały i wyroby Metoda wysokosprawnej Normy Procedury badawcze zywnoscia i inne materialy i wyroby Metoda wysokosprawnej Normy Procedury badawcze","categories":["materials","food"],"row_index":464,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","search_en":"żywnością i inne materiały i wyroby Metoda wysokosprawnej Non-Food Products and Packaging Testing Laboratory Normy Procedury badawcze","technique_en":"Metoda wysokosprawnej","test_object_en":"żywnością i inne materiały i wyroby","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"与食品接触及其他材料与制品 非食品产品与包装检测实验室 Normy Procedury badawcze","test_object_zh":"与食品接触及其他材料与制品"},{"_id":"6a7d76396040ebab2620d448","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"opakowaniowe E","methodology":"chromatografii cieczowej z detekcją","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"chromatografii cieczowej z detekcją","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"opakowaniowe E chromatografii cieczowej z detekcją Normy Procedury badawcze opakowaniowe E chromatografii cieczowej z detekcja Normy Procedury badawcze","categories":["other"],"row_index":465,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"liquid chromatography with detection","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"opakowaniowe E liquid chromatography with detection Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","test_object_en":"opakowaniowe E","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"包装用 E 非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","test_object_zh":"包装用 E"},{"_id":"6a7d76396040ebab2620d449","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Płyny modelowe po migracji E","methodology":"fluorescencyjną (HPLC-FLD)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"fluorescencyjną (HPLC-FLD)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Płyny modelowe po migracji E fluorescencyjną (HPLC-FLD) Normy Procedury badawcze Plyny modelowe po migracji E fluorescencyjna (HPLC-FLD) Normy Procedury badawcze","categories":["other"],"row_index":466,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"fluorescence (HPLC-FLD)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food simulants after migration E fluorescence (HPLC-FLD) Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","test_object_en":"Food simulants after migration E","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"迁移试验后的食品模拟物 E 非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","test_object_zh":"迁移试验后的食品模拟物 E"},{"_id":"6a7d76396040ebab2620d44a","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Płyny modelowe po migracji E","methodology":"Migracja specyficzna (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Migracja specyficzna (z obliczeń)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Płyny modelowe po migracji E Migracja specyficzna (z obliczeń) Normy Procedury badawcze Plyny modelowe po migracji E Migracja specyficzna (z obliczen) Normy Procedury badawcze","categories":["other"],"row_index":467,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Specific migration (calculated)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food simulants after migration E Specific migration (calculated) Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","test_object_en":"Food simulants after migration E","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"迁移试验后的食品模拟物 E 特定迁移量（由计算得出） 非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","methodology_zh":"特定迁移量（由计算得出）","test_object_zh":"迁移试验后的食品模拟物 E"},{"_id":"6a7d76396040ebab2620d44b","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby do kontaktu z, Migracja globalna do płynów modelowych, Metoda wagowa","methodology":"Migracja globalna do płynów","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Migracja globalna do płynów","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby do kontaktu z, Migracja globalna do płynów modelowych, Metoda wagowa Migracja globalna do płynów Normy Procedury badawcze Materialy i wyroby do kontaktu z, Migracja globalna do plynow modelowych, Metoda wagowa Migracja globalna do plynow Normy Procedury badawcze","categories":["materials"],"row_index":468,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Overall migration into liquids","search_en":"Materials and articles in contact with, Overall migration into food simulants, Gravimetric method Overall migration into liquids Non-Food Products and Packaging Testing Laboratory Normy Procedury badawcze","test_object_en":"Materials and articles in contact with, Overall migration into food simulants, Gravimetric method","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"非食品产品与包装检测实验室 Normy Procedury badawcze"},{"_id":"6a7d76396040ebab2620d44c","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"żywnością i inne materiały i wyroby","methodology":"modelowych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"modelowych","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"żywnością i inne materiały i wyroby modelowych Normy Procedury badawcze zywnoscia i inne materialy i wyroby modelowych Normy Procedury badawcze","categories":["materials","food"],"row_index":469,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"simulants","search_en":"żywnością i inne materiały i wyroby simulants Non-Food Products and Packaging Testing Laboratory Normy Procedury badawcze","test_object_en":"żywnością i inne materiały i wyroby","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"与食品接触及其他材料与制品 非食品产品与包装检测实验室 Normy Procedury badawcze","test_object_zh":"与食品接触及其他材料与制品"},{"_id":"6a7d76396040ebab2620d44d","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"opakowaniowe E","methodology":"","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Metoda wagowa","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"opakowaniowe E Metoda wagowa Normy Procedury badawcze opakowaniowe E Metoda wagowa Normy Procedury badawcze","categories":["other"],"row_index":470,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"opakowaniowe E Gravimetric method Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Gravimetric method","test_object_en":"opakowaniowe E","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"包装用 E 重量法 非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"重量法","test_object_zh":"包装用 E"},{"_id":"6a7d76396040ebab2620d44e","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby do kontaktu z żywnością i inne materiały i wyroby opakowaniowe E, Płyny modelowe po migracji E, Materiały i wyroby do kontaktu z","methodology":"Zawartość monomerów, dodatków,","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość monomerów, dodatków,","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Materiały i wyroby do kontaktu z żywnością i inne materiały i wyroby opakowaniowe E, Płyny modelowe po migracji E, Materiały i wyroby do kontaktu z Zawartość monomerów, dodatków, Normy Procedury badawcze Materialy i wyroby do kontaktu z zywnoscia i inne materialy i wyroby opakowaniowe E, Plyny modelowe po migracji E, Materialy i wyroby do kontaktu z Zawartosc monomerow, dodatkow, Normy Procedury badawcze","categories":["materials","food"],"row_index":471,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Content of monomers, additives,","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food contact materials and articles and other packaging materials and articles E, Food simulants after migration E, Materials and articles in contact with Content of monomers, additives, Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","test_object_en":"Food contact materials and articles and other packaging materials and articles E, Food simulants after migration E, Materials and articles in contact with","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze"},{"_id":"6a7d76396040ebab2620d44f","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"żywnością i inne materiały i wyroby","methodology":"zanieczyszczeń i substancji","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"zanieczyszczeń i substancji","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"żywnością i inne materiały i wyroby zanieczyszczeń i substancji Normy Procedury badawcze zywnoscia i inne materialy i wyroby zanieczyszczen i substancji Normy Procedury badawcze","categories":["materials","food"],"row_index":472,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"of impurities and substances","search_en":"żywnością i inne materiały i wyroby of impurities and substances Non-Food Products and Packaging Testing Laboratory Normy Procedury badawcze","test_object_en":"żywnością i inne materiały i wyroby","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"与食品接触及其他材料与制品 非食品产品与包装检测实验室 Normy Procedury badawcze","test_object_zh":"与食品接触及其他材料与制品"},{"_id":"6a7d76396040ebab2620d450","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"opakowaniowe E","methodology":"pomocniczych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"pomocniczych","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"opakowaniowe E pomocniczych Normy Procedury badawcze opakowaniowe E pomocniczych Normy Procedury badawcze","categories":["other"],"row_index":473,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"pomocniczych","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"opakowaniowe E pomocniczych Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","test_object_en":"opakowaniowe E","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"包装用 E 非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","test_object_zh":"包装用 E"},{"_id":"6a7d76396040ebab2620d451","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Płyny modelowe po migracji E","methodology":"","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-"],"computed":[],"activity":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Płyny modelowe po migracji E Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC- Normy Procedury badawcze Plyny modelowe po migracji E Metoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC- Normy Procedury badawcze","categories":["other"],"row_index":474,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food simulants after migration E High-performance liquid chromatography with spectrophotometric detection (HPLC- Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-","test_object_en":"Food simulants after migration E","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"迁移试验后的食品模拟物 E 非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","test_object_zh":"迁移试验后的食品模拟物 E"},{"_id":"6a7d76396040ebab2620d452","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Płyny modelowe po migracji E","methodology":"UV/Vis), detekcją matrycą diodową (HPLC-DAD)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"UV/Vis), detekcją matrycą diodową (HPLC-DAD)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Płyny modelowe po migracji E UV/Vis), detekcją matrycą diodową (HPLC-DAD) Normy Procedury badawcze Plyny modelowe po migracji E UV/Vis), detekcja matryca diodowa (HPLC-DAD) Normy Procedury badawcze","categories":["other"],"row_index":475,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"UV/Vis), detekcją matrycą diodową (HPLC-DAD)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food simulants after migration E UV/Vis), detekcją matrycą diodową (HPLC-DAD) Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","test_object_en":"Food simulants after migration E","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"迁移试验后的食品模拟物 E 非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","test_object_zh":"迁移试验后的食品模拟物 E"},{"_id":"6a7d76396040ebab2620d453","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Płyny modelowe po migracji E","methodology":"Migracja specyficzna (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Migracja specyficzna (z obliczeń)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Płyny modelowe po migracji E Migracja specyficzna (z obliczeń) Normy Procedury badawcze Plyny modelowe po migracji E Migracja specyficzna (z obliczen) Normy Procedury badawcze","categories":["other"],"row_index":476,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Specific migration (calculated)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food simulants after migration E Specific migration (calculated) Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","test_object_en":"Food simulants after migration E","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"迁移试验后的食品模拟物 E 特定迁移量（由计算得出） 非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","methodology_zh":"特定迁移量（由计算得出）","test_object_zh":"迁移试验后的食品模拟物 E"},{"_id":"6a7d76396040ebab2620d454","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby do kontaktu z żywnością i inne materiały i wyroby opakowaniowe E, Płyny modelowe po migracji E","methodology":"Zawartość lotnych i półlotnych monomerów, dodatków, zanieczyszczeń i substancji pomocniczych","parameters":[],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID) oraz z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID) oraz z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość lotnych i półlotnych monomerów, dodatków, zanieczyszczeń i substancji pomocniczych\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID) oraz z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Materiały i wyroby do kontaktu z żywnością i inne materiały i wyroby opakowaniowe E, Płyny modelowe po migracji E Zawartość lotnych i półlotnych monomerów, dodatków, zanieczyszczeń i substancji pomocniczych\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID) oraz z detekcją płomieniowo-jonizacyjną (GC-FID) Normy Procedury badawcze Materialy i wyroby do kontaktu z zywnoscia i inne materialy i wyroby opakowaniowe E, Plyny modelowe po migracji E Zawartosc lotnych i pollotnych monomerow, dodatkow, zanieczyszczen i substancji pomocniczych\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja plomieniowo-jonizacyjna (HS-GC-FID) oraz z detekcja plomieniowo-jonizacyjna (GC-FID) Normy Procedury badawcze","categories":["materials","food"],"row_index":477,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Content of volatile and semi-volatile monomers, additives, impurities and processing aids","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food contact materials and articles and other packaging materials and articles E, Food simulants after migration E Content of volatile and semi-volatile monomers, additives, impurities and processing aids Gas chromatography with headspace analysis and flame ionization detection (HS-GC-FID) and with flame ionization detection (GC-FID) Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Gas chromatography with headspace analysis and flame ionization detection (HS-GC-FID) and with flame ionization detection (GC-FID)","test_object_en":"Food contact materials and articles and other packaging materials and articles E, Food simulants after migration E","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品接触材料与制品及其他包装材料与制品 E、迁移试验后的食品模拟物 E 非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","test_object_zh":"食品接触材料与制品及其他包装材料与制品 E、迁移试验后的食品模拟物 E"},{"_id":"6a7d76396040ebab2620d455","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby do kontaktu z żywnością i inne materiały i wyroby opakowaniowe E, Płyny modelowe po migracji E","methodology":"Migracja specyficzna (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Migracja specyficzna (z obliczeń)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Materiały i wyroby do kontaktu z żywnością i inne materiały i wyroby opakowaniowe E, Płyny modelowe po migracji E Migracja specyficzna (z obliczeń) Normy Procedury badawcze Materialy i wyroby do kontaktu z zywnoscia i inne materialy i wyroby opakowaniowe E, Plyny modelowe po migracji E Migracja specyficzna (z obliczen) Normy Procedury badawcze","categories":["materials","food"],"row_index":478,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Specific migration (calculated)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food contact materials and articles and other packaging materials and articles E, Food simulants after migration E Specific migration (calculated) Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","test_object_en":"Food contact materials and articles and other packaging materials and articles E, Food simulants after migration E","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品接触材料与制品及其他包装材料与制品 E、迁移试验后的食品模拟物 E 特定迁移量（由计算得出） 非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","test_object_zh":"食品接触材料与制品及其他包装材料与制品 E、迁移试验后的食品模拟物 E","methodology_zh":"特定迁移量（由计算得出）"},{"_id":"6a7d76396040ebab2620d456","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych i gumy E, Materiały i wyroby z papieru, tektury E","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznych i polichlorowanych bifenyli","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznych i polichlorowanych bifenyli\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych i gumy E, Materiały i wyroby z papieru, tektury E Zawartość wielopierścieniowych węglowodorów aromatycznych i polichlorowanych bifenyli\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) Normy Procedury badawcze Materialy i wyroby z tworzyw sztucznych i gumy E, Materialy i wyroby z papieru, tektury E Zawartosc wielopierscieniowych weglowodorow aromatycznych i polichlorowanych bifenyli\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) Normy Procedury badawcze","categories":["materials"],"row_index":479,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Content of polycyclic aromatic hydrocarbons and polychlorinated biphenyls","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Plastic and rubber materials and articles E, Paper and board materials and articles E Content of polycyclic aromatic hydrocarbons and polychlorinated biphenyls Gas chromatography with mass spectrometry detection (GC-MS) Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Plastic and rubber materials and articles E, Paper and board materials and articles E","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"气相色谱-质谱法（GC-MS） 非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"气相色谱-质谱法（GC-MS）"},{"_id":"6a7d76396040ebab2620d457","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych i gumy E, Materiały i wyroby z papieru, tektury E, Zabawki E","methodology":"Zawartość monomerów, dodatków, zanieczyszczeń i substancji pomocniczych","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)"],"computed":[],"activity":"Zawartość monomerów, dodatków, zanieczyszczeń i substancji pomocniczych\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych i gumy E, Materiały i wyroby z papieru, tektury E, Zabawki E Zawartość monomerów, dodatków, zanieczyszczeń i substancji pomocniczych\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS) Normy Procedury badawcze Materialy i wyroby z tworzyw sztucznych i gumy E, Materialy i wyroby z papieru, tektury E, Zabawki E Zawartosc monomerow, dodatkow, zanieczyszczen i substancji pomocniczych\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC-MS-MS) Normy Procedury badawcze","categories":["materials"],"row_index":480,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Content of monomers, additives, impurities and auxiliary substances","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Plastic and rubber materials and articles E, Paper and board materials and articles E, Toys E Content of monomers, additives, impurities and auxiliary substances Gas chromatography with tandem mass spectrometry detection (GC-MS-MS) Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Gas chromatography with tandem mass spectrometry detection (GC-MS-MS)","test_object_en":"Plastic and rubber materials and articles E, Paper and board materials and articles E, Toys E","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"气相色谱-串联质谱法（GC-MS-MS） 非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"气相色谱-串联质谱法（GC-MS-MS）"},{"_id":"6a7d76396040ebab2620d458","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych i gumy E, Materiały i wyroby z papieru, tektury E, Świece, parafiny, woski E","methodology":"Zawartość lotnych związków organicznych i rozpuszczalników organicznych","parameters":[],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID) oraz spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID) oraz spektrometrią mas (HS-GC-MS)"],"computed":[],"activity":"Zawartość lotnych związków organicznych i rozpuszczalników organicznych\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID) oraz spektrometrią mas (HS-GC-MS)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych i gumy E, Materiały i wyroby z papieru, tektury E, Świece, parafiny, woski E Zawartość lotnych związków organicznych i rozpuszczalników organicznych\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID) oraz spektrometrią mas (HS-GC-MS) Normy Procedury badawcze Materialy i wyroby z tworzyw sztucznych i gumy E, Materialy i wyroby z papieru, tektury E, Swiece, parafiny, woski E Zawartosc lotnych zwiazkow organicznych i rozpuszczalnikow organicznych\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja plomieniowo-jonizacyjna (HS-GC-FID) oraz spektrometria mas (HS-GC-MS) Normy Procedury badawcze","categories":["materials"],"row_index":481,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Content of volatile organic compounds and organic solvents","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Plastic and rubber materials and articles E, Paper and board materials and articles E, Candles, paraffins, waxes E Content of volatile organic compounds and organic solvents Gas chromatography with headspace analysis and flame ionization detection (HS-GC-FID) and mass spectrometry (HS-GC-MS) Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Gas chromatography with headspace analysis and flame ionization detection (HS-GC-FID) and mass spectrometry (HS-GC-MS)","test_object_en":"Plastic and rubber materials and articles E, Paper and board materials and articles E, Candles, paraffins, waxes E","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze"},{"_id":"6a7d76396040ebab2620d459","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby do kontaktu z żywnością i inne materiały i wyroby opakowaniowe E, Płyny modelowe po migracji E","methodology":"Zawartość pierwiastków","parameters":[],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Zawartość pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Materiały i wyroby do kontaktu z żywnością i inne materiały i wyroby opakowaniowe E, Płyny modelowe po migracji E Zawartość pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) Normy Procedury badawcze Materialy i wyroby do kontaktu z zywnoscia i inne materialy i wyroby opakowaniowe E, Plyny modelowe po migracji E Zawartosc pierwiastkow\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) Normy Procedury badawcze","categories":["materials","food"],"row_index":482,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Element content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food contact materials and articles and other packaging materials and articles E, Food simulants after migration E Element content Inductively coupled plasma mass spectrometry (ICP-MS) Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Food contact materials and articles and other packaging materials and articles E, Food simulants after migration E","lab_section_zh":"非食品产品与包装检测实验室","methodology_zh":"元素含量","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品接触材料与制品及其他包装材料与制品 E、迁移试验后的食品模拟物 E 元素含量 电感耦合等离子体质谱法（ICP-MS） 非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"食品接触材料与制品及其他包装材料与制品 E、迁移试验后的食品模拟物 E"},{"_id":"6a7d76396040ebab2620d45a","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby do kontaktu z żywnością i inne materiały i wyroby opakowaniowe E, Płyny modelowe po migracji E","methodology":"Migracja specyficzna (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Migracja specyficzna (z obliczeń)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Materiały i wyroby do kontaktu z żywnością i inne materiały i wyroby opakowaniowe E, Płyny modelowe po migracji E Migracja specyficzna (z obliczeń) Normy Procedury badawcze Materialy i wyroby do kontaktu z zywnoscia i inne materialy i wyroby opakowaniowe E, Plyny modelowe po migracji E Migracja specyficzna (z obliczen) Normy Procedury badawcze","categories":["materials","food"],"row_index":483,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Specific migration (calculated)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food contact materials and articles and other packaging materials and articles E, Food simulants after migration E Specific migration (calculated) Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","test_object_en":"Food contact materials and articles and other packaging materials and articles E, Food simulants after migration E","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品接触材料与制品及其他包装材料与制品 E、迁移试验后的食品模拟物 E 特定迁移量（由计算得出） 非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","test_object_zh":"食品接触材料与制品及其他包装材料与制品 E、迁移试验后的食品模拟物 E","methodology_zh":"特定迁移量（由计算得出）"},{"_id":"6a7d76396040ebab2620d45b","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby do kontaktu z","methodology":"Zawartość dodatków,","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość dodatków,","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby do kontaktu z Zawartość dodatków, Procedury badawcze Materialy i wyroby do kontaktu z Zawartosc dodatkow, Procedury badawcze","categories":["materials"],"row_index":484,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Additive content,","search_en":"Materiały i wyroby do kontaktu z Additive content, Non-Food Products and Packaging Testing Laboratory Procedury badawcze","test_object_en":"Materiały i wyroby do kontaktu z","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"非食品产品与包装检测实验室 Procedury badawcze"},{"_id":"6a7d76396040ebab2620d45c","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"żywnością i inne materiały i wyroby","methodology":"zanieczyszczeń i substancji","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"zanieczyszczeń i substancji","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"żywnością i inne materiały i wyroby zanieczyszczeń i substancji Procedury badawcze zywnoscia i inne materialy i wyroby zanieczyszczen i substancji Procedury badawcze","categories":["materials","food"],"row_index":485,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"of impurities and substances","search_en":"żywnością i inne materiały i wyroby of impurities and substances Non-Food Products and Packaging Testing Laboratory Procedury badawcze","test_object_en":"żywnością i inne materiały i wyroby","lab_section_zh":"非食品产品与包装检测实验室","search_zh":"与食品接触及其他材料与制品 非食品产品与包装检测实验室 Procedury badawcze","test_object_zh":"与食品接触及其他材料与制品"},{"_id":"6a7d76396040ebab2620d45d","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"opakowaniowe E","methodology":"pomocniczych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"pomocniczych","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"opakowaniowe E pomocniczych Procedury badawcze opakowaniowe E pomocniczych Procedury badawcze","categories":["other"],"row_index":486,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"pomocniczych","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"opakowaniowe E pomocniczych Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Procedury badawcze","test_object_en":"opakowaniowe E","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"包装用 E 非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Procedury badawcze","test_object_zh":"包装用 E"},{"_id":"6a7d76396040ebab2620d45e","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Płyny modelowe po migracji E","methodology":"","parameters":[],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Metoda spektrofotometryczna","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Płyny modelowe po migracji E Metoda spektrofotometryczna Procedury badawcze Plyny modelowe po migracji E Metoda spektrofotometryczna Procedury badawcze","categories":["other"],"row_index":487,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food simulants after migration E Spectrophotometric method Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Procedury badawcze","technique_en":"Spectrophotometric method","test_object_en":"Food simulants after migration E","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"迁移试验后的食品模拟物 E 分光光度法 非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Procedury badawcze","technique_zh":"分光光度法","test_object_zh":"迁移试验后的食品模拟物 E"},{"_id":"6a7d76396040ebab2620d45f","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Płyny modelowe po migracji E","methodology":"Migracja specyficzna (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Migracja specyficzna (z obliczeń)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Płyny modelowe po migracji E Migracja specyficzna (z obliczeń) Procedury badawcze Plyny modelowe po migracji E Migracja specyficzna (z obliczen) Procedury badawcze","categories":["other"],"row_index":488,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Specific migration (calculated)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food simulants after migration E Specific migration (calculated) Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Procedury badawcze","test_object_en":"Food simulants after migration E","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"迁移试验后的食品模拟物 E 特定迁移量（由计算得出） 非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Procedury badawcze","methodology_zh":"特定迁移量（由计算得出）","test_object_zh":"迁移试验后的食品模拟物 E"},{"_id":"6a7d76396040ebab2620d460","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Zabawki E","methodology":"Migracja pierwiastków","parameters":[],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Migracja pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Zabawki E Migracja pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) Normy Zabawki E Migracja pierwiastkow\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) Normy","categories":["other"],"row_index":489,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Migration of elements","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Toys E Migration of elements Inductively coupled plasma mass spectrometry (ICP-MS) Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Toys E","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"玩具 E 电感耦合等离子体质谱法（ICP-MS） 非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"玩具 E"},{"_id":"6a7d76396040ebab2620d461","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Zabawki E, Materiały i wyroby z tworzyw sztucznych E, Materiały i wyroby z papieru, tektury E","methodology":"Zawartość monomerów, dodatków, zanieczyszczeń i substancji pomocniczych","parameters":[],"technique":"Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","techniques":["Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)"],"computed":[],"activity":"Zawartość monomerów, dodatków, zanieczyszczeń i substancji pomocniczych\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Zabawki E, Materiały i wyroby z tworzyw sztucznych E, Materiały i wyroby z papieru, tektury E Zawartość monomerów, dodatków, zanieczyszczeń i substancji pomocniczych\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS) Procedury badawcze Zabawki E, Materialy i wyroby z tworzyw sztucznych E, Materialy i wyroby z papieru, tektury E Zawartosc monomerow, dodatkow, zanieczyszczen i substancji pomocniczych\nMetoda chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS-MS) Procedury badawcze","categories":["materials"],"row_index":490,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Content of monomers, additives, impurities and auxiliary substances","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Toys E, Plastic materials and articles E, Paper and board materials and articles E Content of monomers, additives, impurities and auxiliary substances Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS) Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Procedury badawcze","technique_en":"Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS)","test_object_en":"Toys E, Plastic materials and articles E, Paper and board materials and articles E","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"液相色谱-串联质谱法（LC-MS-MS） 非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Procedury badawcze","technique_zh":"液相色谱-串联质谱法（LC-MS-MS）"},{"_id":"6a7d76396040ebab2620d462","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Sprzęt elektryczny i elektroniczny oraz jego elementy polimerowe, tekstylne, papierowe i elektroniczne, materiały stosowane do produkcji sprzętu elektrycznego i elektronicznego oraz opakowań E, Zabawki E","methodology":"Zawartość chromu sześciowartościowego","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej ze spektrometrią mas z jonizacją w plazmie indukcyjnie sprzężonej (HPLC-ICP-MS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej ze spektrometrią mas z jonizacją w plazmie indukcyjnie sprzężonej (HPLC-ICP-MS)"],"computed":[],"activity":"Zawartość chromu sześciowartościowego\nMetoda wysokosprawnej chromatografii cieczowej ze spektrometrią mas z jonizacją w plazmie indukcyjnie sprzężonej (HPLC-ICP-MS)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Sprzęt elektryczny i elektroniczny oraz jego elementy polimerowe, tekstylne, papierowe i elektroniczne, materiały stosowane do produkcji sprzętu elektrycznego i elektronicznego oraz opakowań E, Zabawki E Zawartość chromu sześciowartościowego\nMetoda wysokosprawnej chromatografii cieczowej ze spektrometrią mas z jonizacją w plazmie indukcyjnie sprzężonej (HPLC-ICP-MS) Normy Sprzet elektryczny i elektroniczny oraz jego elementy polimerowe, tekstylne, papierowe i elektroniczne, materialy stosowane do produkcji sprzetu elektrycznego i elektronicznego oraz opakowan E, Zabawki E Zawartosc chromu szesciowartosciowego\nMetoda wysokosprawnej chromatografii cieczowej ze spektrometria mas z jonizacja w plazmie indukcyjnie sprzezonej (HPLC-ICP-MS) Normy","categories":["materials","electronics"],"row_index":491,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Hexavalent chromium content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Electrical and electronic equipment and its polymer, textile, paper and electronic components, materials used in the manufacture of electrical and electronic equipment and packaging E, Toys E Hexavalent chromium content High-performance liquid chromatography with inductively coupled plasma mass spectrometry (HPLC-ICP-MS) Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy","technique_en":"High-performance liquid chromatography with inductively coupled plasma mass spectrometry (HPLC-ICP-MS)","test_object_en":"Electrical and electronic equipment and its polymer, textile, paper and electronic components, materials used in the manufacture of electrical and electronic equipment and packaging E, Toys E","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy"},{"_id":"6a7d76396040ebab2620d463","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Zabawki E, Materiały i wyroby do kontaktu z żywnością i inne materiały i wyroby opakowaniowe oraz ich wyciągi wodne E","methodology":"Zawartość dodatków, zanieczyszczeń i substancji pomocniczych","parameters":[],"technique":"Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","techniques":["Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)"],"computed":[],"activity":"Zawartość dodatków, zanieczyszczeń i substancji pomocniczych\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Zabawki E, Materiały i wyroby do kontaktu z żywnością i inne materiały i wyroby opakowaniowe oraz ich wyciągi wodne E Zawartość dodatków, zanieczyszczeń i substancji pomocniczych\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS) Normy Procedury badawcze Zabawki E, Materialy i wyroby do kontaktu z zywnoscia i inne materialy i wyroby opakowaniowe oraz ich wyciagi wodne E Zawartosc dodatkow, zanieczyszczen i substancji pomocniczych\nMetoda chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS-MS) Normy Procedury badawcze","categories":["materials","food"],"row_index":492,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Content of additives, impurities and processing aids","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Toys E, Materials and articles for contact with food and other packaging materials and articles and their aqueous extracts E Content of additives, impurities and processing aids Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS) Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS)","test_object_en":"Toys E, Materials and articles for contact with food and other packaging materials and articles and their aqueous extracts E","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"添加剂、杂质与助剂含量 液相色谱-串联质谱法（LC-MS-MS） 非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"液相色谱-串联质谱法（LC-MS-MS）","methodology_zh":"添加剂、杂质与助剂含量"},{"_id":"6a7d76396040ebab2620d464","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tekstyliów, skóry E","methodology":"Zawartość amin","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)"],"computed":[],"activity":"Zawartość amin\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Materiały i wyroby z tekstyliów, skóry E Zawartość amin\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS) Procedury badawcze Materialy i wyroby z tekstyliow, skory E Zawartosc amin\nMetoda wysokosprawnej chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS-MS) Procedury badawcze","categories":["materials"],"row_index":493,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Amine content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Materials and articles made of textiles, leather E Amine content High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS-MS) Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Procedury badawcze","technique_en":"High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS-MS)","test_object_en":"Materials and articles made of textiles, leather E","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"高效液相色谱-串联质谱法（LC-MS-MS） 非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Procedury badawcze","technique_zh":"高效液相色谱-串联质谱法（LC-MS-MS）"},{"_id":"6a7d76396040ebab2620d465","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby do kontaktu z żywnością i inne materiały i wyroby opakowaniowe E, Płyny modelowe po migracji E","methodology":"Zawartość dodatków, zanieczyszczeń i substancji pomocniczych","parameters":[],"technique":"Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","techniques":["Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)"],"computed":[],"activity":"Zawartość dodatków, zanieczyszczeń i substancji pomocniczych\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Materiały i wyroby do kontaktu z żywnością i inne materiały i wyroby opakowaniowe E, Płyny modelowe po migracji E Zawartość dodatków, zanieczyszczeń i substancji pomocniczych\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS) Procedury badawcze Materialy i wyroby do kontaktu z zywnoscia i inne materialy i wyroby opakowaniowe E, Plyny modelowe po migracji E Zawartosc dodatkow, zanieczyszczen i substancji pomocniczych\nMetoda chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS-MS) Procedury badawcze","categories":["materials","food"],"row_index":494,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Content of additives, impurities and processing aids","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food contact materials and articles and other packaging materials and articles E, Food simulants after migration E Content of additives, impurities and processing aids Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS) Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Procedury badawcze","technique_en":"Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS)","test_object_en":"Food contact materials and articles and other packaging materials and articles E, Food simulants after migration E","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品接触材料与制品及其他包装材料与制品 E、迁移试验后的食品模拟物 E 添加剂、杂质与助剂含量 液相色谱-串联质谱法（LC-MS-MS） 非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Procedury badawcze","technique_zh":"液相色谱-串联质谱法（LC-MS-MS）","test_object_zh":"食品接触材料与制品及其他包装材料与制品 E、迁移试验后的食品模拟物 E","methodology_zh":"添加剂、杂质与助剂含量"},{"_id":"6a7d76396040ebab2620d466","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby do kontaktu z żywnością i inne materiały i wyroby opakowaniowe E, Płyny modelowe po migracji E","methodology":"Migracja specyficzna (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Migracja specyficzna (z obliczeń)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Materiały i wyroby do kontaktu z żywnością i inne materiały i wyroby opakowaniowe E, Płyny modelowe po migracji E Migracja specyficzna (z obliczeń) Procedury badawcze Materialy i wyroby do kontaktu z zywnoscia i inne materialy i wyroby opakowaniowe E, Plyny modelowe po migracji E Migracja specyficzna (z obliczen) Procedury badawcze","categories":["materials","food"],"row_index":495,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Specific migration (calculated)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food contact materials and articles and other packaging materials and articles E, Food simulants after migration E Specific migration (calculated) Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Procedury badawcze","test_object_en":"Food contact materials and articles and other packaging materials and articles E, Food simulants after migration E","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品接触材料与制品及其他包装材料与制品 E、迁移试验后的食品模拟物 E 特定迁移量（由计算得出） 非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Procedury badawcze","test_object_zh":"食品接触材料与制品及其他包装材料与制品 E、迁移试验后的食品模拟物 E","methodology_zh":"特定迁移量（由计算得出）"},{"_id":"6a7d76396040ebab2620d467","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby do kontaktu z żywnością i inne materiały i wyroby opakowaniowe E, Płyny modelowe po migracji E","methodology":"Zawartość dodatków, zanieczyszczeń i substancji pomocniczych","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)"],"computed":[],"activity":"Zawartość dodatków, zanieczyszczeń i substancji pomocniczych\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Materiały i wyroby do kontaktu z żywnością i inne materiały i wyroby opakowaniowe E, Płyny modelowe po migracji E Zawartość dodatków, zanieczyszczeń i substancji pomocniczych\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS) Procedury badawcze Materialy i wyroby do kontaktu z zywnoscia i inne materialy i wyroby opakowaniowe E, Plyny modelowe po migracji E Zawartosc dodatkow, zanieczyszczen i substancji pomocniczych\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC-MS-MS) Procedury badawcze","categories":["materials","food"],"row_index":496,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Content of additives, impurities and processing aids","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food contact materials and articles and other packaging materials and articles E, Food simulants after migration E Content of additives, impurities and processing aids Gas chromatography with tandem mass spectrometry detection (GC-MS-MS) Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Procedury badawcze","technique_en":"Gas chromatography with tandem mass spectrometry detection (GC-MS-MS)","test_object_en":"Food contact materials and articles and other packaging materials and articles E, Food simulants after migration E","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品接触材料与制品及其他包装材料与制品 E、迁移试验后的食品模拟物 E 添加剂、杂质与助剂含量 气相色谱-串联质谱法（GC-MS-MS） 非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Procedury badawcze","technique_zh":"气相色谱-串联质谱法（GC-MS-MS）","test_object_zh":"食品接触材料与制品及其他包装材料与制品 E、迁移试验后的食品模拟物 E","methodology_zh":"添加剂、杂质与助剂含量"},{"_id":"6a7d76396040ebab2620d468","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby do kontaktu z żywnością i inne materiały i wyroby opakowaniowe E, Płyny modelowe po migracji E","methodology":"Migracja specyficzna (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Migracja specyficzna (z obliczeń)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Materiały i wyroby do kontaktu z żywnością i inne materiały i wyroby opakowaniowe E, Płyny modelowe po migracji E Migracja specyficzna (z obliczeń) Procedury badawcze Materialy i wyroby do kontaktu z zywnoscia i inne materialy i wyroby opakowaniowe E, Plyny modelowe po migracji E Migracja specyficzna (z obliczen) Procedury badawcze","categories":["materials","food"],"row_index":497,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Specific migration (calculated)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food contact materials and articles and other packaging materials and articles E, Food simulants after migration E Specific migration (calculated) Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Procedury badawcze","test_object_en":"Food contact materials and articles and other packaging materials and articles E, Food simulants after migration E","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品接触材料与制品及其他包装材料与制品 E、迁移试验后的食品模拟物 E 特定迁移量（由计算得出） 非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Procedury badawcze","test_object_zh":"食品接触材料与制品及其他包装材料与制品 E、迁移试验后的食品模拟物 E","methodology_zh":"特定迁移量（由计算得出）"},{"_id":"6a7d76396040ebab2620d469","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby do kontaktu z żywnością i inne materiały i wyroby opakowaniowe E, Płyny modelowe po migracji E","methodology":"Zawartość olejów mineralnych (MOSH, MOAH)","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną w połączeniu z układem wysokosprawnej chromatografii cieczowej (HPLC-GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną w połączeniu z układem wysokosprawnej chromatografii cieczowej (HPLC-GC-FID)"],"computed":[],"activity":"Zawartość olejów mineralnych (MOSH, MOAH)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną w połączeniu z układem wysokosprawnej chromatografii cieczowej (HPLC-GC-FID)","reference":"PB-396/GC","norm_bases":["PB-396/GC"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Materiały i wyroby do kontaktu z żywnością i inne materiały i wyroby opakowaniowe E, Płyny modelowe po migracji E Zawartość olejów mineralnych (MOSH, MOAH)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną w połączeniu z układem wysokosprawnej chromatografii cieczowej (HPLC-GC-FID) PB-396/GC Materialy i wyroby do kontaktu z zywnoscia i inne materialy i wyroby opakowaniowe E, Plyny modelowe po migracji E Zawartosc olejow mineralnych (MOSH, MOAH)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna w polaczeniu z ukladem wysokosprawnej chromatografii cieczowej (HPLC-GC-FID) PB-396/GC","categories":["materials","food","petro"],"row_index":498,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Mineral oil content (MOSH, MOAH)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food contact materials and articles and other packaging materials and articles E, Food simulants after migration E Mineral oil content (MOSH, MOAH) Gas chromatography with flame ionization detection coupled with a high-performance liquid chromatography system (HPLC-GC-FID) Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. PB-396/GC","technique_en":"Gas chromatography with flame ionization detection coupled with a high-performance liquid chromatography system (HPLC-GC-FID)","test_object_en":"Food contact materials and articles and other packaging materials and articles E, Food simulants after migration E","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品接触材料与制品及其他包装材料与制品 E、迁移试验后的食品模拟物 E 非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 PB-396/GC","test_object_zh":"食品接触材料与制品及其他包装材料与制品 E、迁移试验后的食品模拟物 E"},{"_id":"6a7d76396040ebab2620d46a","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby do kontaktu z żywnością i inne materiały i wyroby opakowaniowe E, Płyny modelowe po migracji E","methodology":"Migracja specyficzna (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Migracja specyficzna (z obliczeń)","reference":"PB-396/GC","norm_bases":["PB-396/GC"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Materiały i wyroby do kontaktu z żywnością i inne materiały i wyroby opakowaniowe E, Płyny modelowe po migracji E Migracja specyficzna (z obliczeń) PB-396/GC Materialy i wyroby do kontaktu z zywnoscia i inne materialy i wyroby opakowaniowe E, Plyny modelowe po migracji E Migracja specyficzna (z obliczen) PB-396/GC","categories":["materials","food"],"row_index":499,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Specific migration (calculated)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food contact materials and articles and other packaging materials and articles E, Food simulants after migration E Specific migration (calculated) Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. PB-396/GC","test_object_en":"Food contact materials and articles and other packaging materials and articles E, Food simulants after migration E","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品接触材料与制品及其他包装材料与制品 E、迁移试验后的食品模拟物 E 特定迁移量（由计算得出） 非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 PB-396/GC","test_object_zh":"食品接触材料与制品及其他包装材料与制品 E、迁移试验后的食品模拟物 E","methodology_zh":"特定迁移量（由计算得出）"},{"_id":"6a7d76396040ebab2620d46b","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby do kontaktu z żywnością i inne materiały i wyroby opakowaniowe E, Płyny modelowe po migracji E","methodology":"Screening substancji dodanych w sposób niezamierzony (NIAS), zawartość","parameters":[{"name":"I detektorem płomieniowo-jonizacyjnym (GC-MS-FID)"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas"],"computed":[],"activity":"Screening substancji dodanych w sposób niezamierzony (NIAS), zawartość\nI detektorem płomieniowo-jonizacyjnym (GC-MS-FID)\nMetoda chromatografii gazowej z detekcją spektrometrią mas","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Materiały i wyroby do kontaktu z żywnością i inne materiały i wyroby opakowaniowe E, Płyny modelowe po migracji E Screening substancji dodanych w sposób niezamierzony (NIAS), zawartość\nI detektorem płomieniowo-jonizacyjnym (GC-MS-FID)\nMetoda chromatografii gazowej z detekcją spektrometrią mas Procedury badawcze Materialy i wyroby do kontaktu z zywnoscia i inne materialy i wyroby opakowaniowe E, Plyny modelowe po migracji E Screening substancji dodanych w sposob niezamierzony (NIAS), zawartosc\nI detektorem plomieniowo-jonizacyjnym (GC-MS-FID)\nMetoda chromatografii gazowej z detekcja spektrometria mas Procedury badawcze","categories":["materials","food"],"row_index":500,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Screening of non-intentionally added substances (NIAS), content","parameters_en":[{"name":"And flame ionisation detector (GC-MS-FID)"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food contact materials and articles and other packaging materials and articles E, Food simulants after migration E Screening of non-intentionally added substances (NIAS), content Gas chromatography with mass spectrometry detection Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. And flame ionisation detector (GC-MS-FID) Procedury badawcze","technique_en":"Gas chromatography with mass spectrometry detection","test_object_en":"Food contact materials and articles and other packaging materials and articles E, Food simulants after migration E","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品接触材料与制品及其他包装材料与制品 E、迁移试验后的食品模拟物 E 非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Procedury badawcze","test_object_zh":"食品接触材料与制品及其他包装材料与制品 E、迁移试验后的食品模拟物 E"},{"_id":"6a7d76396040ebab2620d46c","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby do kontaktu z żywnością i inne materiały i wyroby opakowaniowe E, Płyny modelowe po migracji E","methodology":"Migracja specyficzna (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Migracja specyficzna (z obliczeń)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Materiały i wyroby do kontaktu z żywnością i inne materiały i wyroby opakowaniowe E, Płyny modelowe po migracji E Migracja specyficzna (z obliczeń) Procedury badawcze Materialy i wyroby do kontaktu z zywnoscia i inne materialy i wyroby opakowaniowe E, Plyny modelowe po migracji E Migracja specyficzna (z obliczen) Procedury badawcze","categories":["materials","food"],"row_index":501,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Specific migration (calculated)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food contact materials and articles and other packaging materials and articles E, Food simulants after migration E Specific migration (calculated) Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Procedury badawcze","test_object_en":"Food contact materials and articles and other packaging materials and articles E, Food simulants after migration E","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品接触材料与制品及其他包装材料与制品 E、迁移试验后的食品模拟物 E 特定迁移量（由计算得出） 非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Procedury badawcze","test_object_zh":"食品接触材料与制品及其他包装材料与制品 E、迁移试验后的食品模拟物 E","methodology_zh":"特定迁移量（由计算得出）"},{"_id":"6a7d76396040ebab2620d46d","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby do kontaktu z żywnością i inne materiały i wyroby opakowaniowe E, Płyny modelowe po migracji E","methodology":"Zawartość dodatków, zanieczyszczeń i substancji pomocniczych","parameters":[],"technique":"Metoda chromatografii cieczowej z detekcją spektrometrią mas i czasem przelotu (LC-QTOF-MS)","techniques":["Metoda chromatografii cieczowej z detekcją spektrometrią mas i czasem przelotu (LC-QTOF-MS)"],"computed":[],"activity":"Zawartość dodatków, zanieczyszczeń i substancji pomocniczych\nMetoda chromatografii cieczowej z detekcją spektrometrią mas i czasem przelotu (LC-QTOF-MS)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Materiały i wyroby do kontaktu z żywnością i inne materiały i wyroby opakowaniowe E, Płyny modelowe po migracji E Zawartość dodatków, zanieczyszczeń i substancji pomocniczych\nMetoda chromatografii cieczowej z detekcją spektrometrią mas i czasem przelotu (LC-QTOF-MS) Procedury badawcze Materialy i wyroby do kontaktu z zywnoscia i inne materialy i wyroby opakowaniowe E, Plyny modelowe po migracji E Zawartosc dodatkow, zanieczyszczen i substancji pomocniczych\nMetoda chromatografii cieczowej z detekcja spektrometria mas i czasem przelotu (LC-QTOF-MS) Procedury badawcze","categories":["materials","food"],"row_index":502,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Content of additives, impurities and processing aids","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food contact materials and articles and other packaging materials and articles E, Food simulants after migration E Content of additives, impurities and processing aids Liquid chromatography with quadrupole time-of-flight mass spectrometry detection (LC-QTOF-MS) Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Procedury badawcze","technique_en":"Liquid chromatography with quadrupole time-of-flight mass spectrometry detection (LC-QTOF-MS)","test_object_en":"Food contact materials and articles and other packaging materials and articles E, Food simulants after migration E","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品接触材料与制品及其他包装材料与制品 E、迁移试验后的食品模拟物 E 添加剂、杂质与助剂含量 非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Procedury badawcze","test_object_zh":"食品接触材料与制品及其他包装材料与制品 E、迁移试验后的食品模拟物 E","methodology_zh":"添加剂、杂质与助剂含量"},{"_id":"6a7d76396040ebab2620d46e","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby do kontaktu z żywnością i inne materiały i wyroby opakowaniowe E, Płyny modelowe po migracji E","methodology":"Migracja specyficzna (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Migracja specyficzna (z obliczeń)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Materiały i wyroby do kontaktu z żywnością i inne materiały i wyroby opakowaniowe E, Płyny modelowe po migracji E Migracja specyficzna (z obliczeń) Procedury badawcze Materialy i wyroby do kontaktu z zywnoscia i inne materialy i wyroby opakowaniowe E, Plyny modelowe po migracji E Migracja specyficzna (z obliczen) Procedury badawcze","categories":["materials","food"],"row_index":503,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Specific migration (calculated)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food contact materials and articles and other packaging materials and articles E, Food simulants after migration E Specific migration (calculated) Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Procedury badawcze","test_object_en":"Food contact materials and articles and other packaging materials and articles E, Food simulants after migration E","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品接触材料与制品及其他包装材料与制品 E、迁移试验后的食品模拟物 E 特定迁移量（由计算得出） 非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Procedury badawcze","test_object_zh":"食品接触材料与制品及其他包装材料与制品 E、迁移试验后的食品模拟物 E","methodology_zh":"特定迁移量（由计算得出）"},{"_id":"6a7d76396040ebab2620d46f","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych E, Materiały i wyroby z papieru, tektury E","methodology":"Zawartość olejów mineralnych (MOSH/POSH, MOAH)","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną w połączeniu z układem wysokosprawnej chromatografii cieczowej (HPLC-GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną w połączeniu z układem wysokosprawnej chromatografii cieczowej (HPLC-GC-FID)"],"computed":[],"activity":"Zawartość olejów mineralnych (MOSH/POSH, MOAH)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną w połączeniu z układem wysokosprawnej chromatografii cieczowej (HPLC-GC-FID)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Badań Produktów Nieżywnościowych i Opakowań","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych E, Materiały i wyroby z papieru, tektury E Zawartość olejów mineralnych (MOSH/POSH, MOAH)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną w połączeniu z układem wysokosprawnej chromatografii cieczowej (HPLC-GC-FID) Procedury badawcze Materialy i wyroby z tworzyw sztucznych E, Materialy i wyroby z papieru, tektury E Zawartosc olejow mineralnych (MOSH/POSH, MOAH)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna w polaczeniu z ukladem wysokosprawnej chromatografii cieczowej (HPLC-GC-FID) Procedury badawcze","categories":["materials","petro"],"row_index":504,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Non-Food Products and Packaging Testing Laboratory","methodology_en":"Mineral oil content (MOSH/POSH, MOAH)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Plastic materials and articles E, Paper and board materials and articles E Mineral oil content (MOSH/POSH, MOAH) Gas chromatography with flame ionization detection coupled with a high-performance liquid chromatography system (HPLC-GC-FID) Non-Food Products and Packaging Testing Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection coupled with a high-performance liquid chromatography system (HPLC-GC-FID)","test_object_en":"Plastic materials and articles E, Paper and board materials and articles E","lab_section_zh":"非食品产品与包装检测实验室","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"非食品产品与包装检测实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Procedury badawcze"},{"_id":"6a7d76396040ebab2620d470","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Indeks fenolowy","parameters":[{"name":"Zakres","range":"(0,010 – 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Indeks fenolowy\nZakres (0,010 – 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994","norm_bases":["PN-ISO 6439:1994"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Indeks fenolowy\nZakres (0,010 – 5,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 Woda, scieki Indeks fenolowy\nZakres (0,010 – 5,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994","categories":["water"],"row_index":505,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Phenol index","parameters_en":[{"name":"Range","range":"(0,010 – 5,0) mg/l"}],"search_en":"Water, wastewater Phenol index Spectrophotometric method Environmental Analyses Laboratory Gdynia Range PN-ISO 6439:1994","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,010 – 5,0) mg/l"}],"search_zh":"水、废水 酚指数 分光光度法 环境分析实验室 Gdynia 范围 PN-ISO 6439:1994","technique_zh":"分光光度法","test_object_zh":"水、废水","lab_section_zh":"环境分析实验室 Gdynia","methodology_zh":"酚指数"},{"_id":"6a7d76396040ebab2620d471","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,50 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,50 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres (0,50 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla\nZakres (0,50 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":506,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,50 – 1000) mg/l"}],"search_en":"Water, wastewater Kjeldahl nitrogen concentration Titrimetric method Environmental Analyses Laboratory Gdynia Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,50 – 1000) mg/l"}],"search_zh":"水、废水 凯氏氮浓度 滴定法 环境分析实验室 Gdynia 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、废水","lab_section_zh":"环境分析实验室 Gdynia"},{"_id":"6a7d76396040ebab2620d472","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,50 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,50 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,50 – 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,50 – 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":507,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,50 – 1000) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Titrimetric method Environmental Analyses Laboratory Gdynia Range PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,50 – 1000) mg/l"}],"search_zh":"水、废水 氨氮浓度 滴定法 环境分析实验室 Gdynia 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"水、废水","lab_section_zh":"环境分析实验室 Gdynia"},{"_id":"6a7d76396040ebab2620d473","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-102 wyd. IV z dn. 09.02.2022","norm_bases":["PB-102 wyd. IV z dn. 09.02.2022"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu ogólnego (z obliczeń) PB-102 wyd. IV z dn. 09.02.2022 Woda, scieki Stezenie azotu ogolnego (z obliczen) PB-102 wyd. IV z dn. 09.02.2022","categories":["water"],"row_index":508,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water, wastewater Total nitrogen concentration (calculated) Environmental Analyses Laboratory Gdynia PB-102 wyd. IV z dn. 09.02.2022","test_object_en":"Water, wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"水、废水 总氮浓度（计算值） 环境分析实验室 Gdynia PB-102 wyd. IV z dn. 09.02.2022","test_object_zh":"水、废水","lab_section_zh":"环境分析实验室 Gdynia"},{"_id":"6a7d76396040ebab2620d474","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chromu (VI)","parameters":[{"name":"Zakres","range":"(0,01 – 5,0 mg/l)"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chromu (VI)\nZakres (0,01 – 5,0 mg/l)\nMetoda spektrofotometryczna","reference":"Test NANOCOLOR nr 91825 | Instrukcja wyd. z 03.2021","norm_bases":["Test NANOCOLOR nr 91825","Instrukcja wyd. z 03.2021"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chromu (VI)\nZakres (0,01 – 5,0 mg/l)\nMetoda spektrofotometryczna Test NANOCOLOR nr 91825 | Instrukcja wyd. z 03.2021 Woda, scieki Stezenie chromu (VI)\nZakres (0,01 – 5,0 mg/l)\nMetoda spektrofotometryczna Test NANOCOLOR nr 91825 | Instrukcja wyd. z 03.2021","categories":["water"],"row_index":509,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Chromium(VI) concentration","parameters_en":[{"name":"Range","range":"(0,01 – 5,0 mg/l)"}],"search_en":"Water, wastewater Chromium(VI) concentration Spectrophotometric method Environmental Analyses Laboratory Gdynia Range Test NANOCOLOR nr 91825 | Instrukcja wyd. z 03.2021","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,01 – 5,0 mg/l)"}],"search_zh":"水、废水 六价铬浓度 分光光度法 环境分析实验室 Gdynia 范围 Test NANOCOLOR nr 91825 | Instrukcja wyd. z 03.2021","technique_zh":"分光光度法","test_object_zh":"水、废水","lab_section_zh":"环境分析实验室 Gdynia","methodology_zh":"六价铬浓度"},{"_id":"6a7d76396040ebab2620d475","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"3,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 3,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki pH\nZakres 3,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, woda do spozycia przez ludzi, scieki pH\nZakres 3,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":510,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"pH","parameters_en":[{"name":"Range","range":"3,0 – 10,0"}],"search_en":"Water, water intended for human consumption, wastewater pH Potentiometric method Environmental Analyses Laboratory Gdynia Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"3,0 – 10,0"}],"search_zh":"水、生活饮用水、污水 pH 值 电位法 环境分析实验室 Gdynia 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水、污水","lab_section_zh":"环境分析实验室 Gdynia"},{"_id":"6a7d76396040ebab2620d476","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10 – 3000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (10 – 3000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Przewodność elektryczna właściwa\nZakres (10 – 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, woda do spozycia przez ludzi, scieki Przewodnosc elektryczna wlasciwa\nZakres (10 – 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":511,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(10 – 3000) μS/cm"}],"search_en":"Water, water intended for human consumption, wastewater Electrical conductivity Conductometric method Environmental Analyses Laboratory Gdynia Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10 – 3000) μS/cm"}],"search_zh":"水、生活饮用水、污水 电导率 电导法 环境分析实验室 Gdynia 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水、污水","lab_section_zh":"环境分析实验室 Gdynia"},{"_id":"6a7d76396040ebab2620d477","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,20 – 70) mg/l"},{"name":"Stężenie azotu azotanowego"},{"name":"Zakres","range":"(0,045 – 15,8) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres:\nZakres (0,20 – 70) mg/l\nStężenie azotu azotanowego\nZakres (0,045 – 15,8) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie azotanów\nZakres:\nZakres (0,20 – 70) mg/l\nStężenie azotu azotanowego\nZakres (0,045 – 15,8) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda, woda do spozycia przez ludzi, scieki Stezenie azotanow\nZakres:\nZakres (0,20 – 70) mg/l\nStezenie azotu azotanowego\nZakres (0,045 – 15,8) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":512,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(0,20 – 70) mg/l"},{"name":"Nitrate nitrogen concentration"},{"name":"Range","range":"(0,045 – 15,8) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Nitrate concentration Spectrophotometric method Environmental Analyses Laboratory Gdynia Range Nitrate nitrogen concentration Range PN-82/C-04576/08","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 70) mg/l"},{"name":"硝态氮浓度"},{"name":"范围","range":"(0,045 – 15,8) mg/l"}],"search_zh":"水、生活饮用水、污水 硝酸盐浓度 分光光度法 环境分析实验室 Gdynia 范围 硝态氮浓度 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水","lab_section_zh":"环境分析实验室 Gdynia"},{"_id":"6a7d76396040ebab2620d478","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,01 – 1,6) mg/l"},{"name":"Stężenie azotu azotynowego"},{"name":"Zakres","range":"(0,003 – 0,48) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres:\nZakres (0,01 – 1,6) mg/l\nStężenie azotu azotynowego\nZakres (0,003 – 0,48) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie azotynów\nZakres:\nZakres (0,01 – 1,6) mg/l\nStężenie azotu azotynowego\nZakres (0,003 – 0,48) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, woda do spozycia przez ludzi, scieki Stezenie azotynow\nZakres:\nZakres (0,01 – 1,6) mg/l\nStezenie azotu azotynowego\nZakres (0,003 – 0,48) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":513,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,01 – 1,6) mg/l"},{"name":"Nitrite nitrogen concentration"},{"name":"Range","range":"(0,003 – 0,48) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Nitrite concentration Spectrophotometric method Environmental Analyses Laboratory Gdynia Range Nitrite nitrogen concentration Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,01 – 1,6) mg/l"},{"name":"亚硝态氮浓度"},{"name":"范围","range":"(0,003 – 0,48) mg/l"}],"search_zh":"水、生活饮用水、污水 亚硝酸盐浓度 分光光度法 环境分析实验室 Gdynia 范围 亚硝态氮浓度 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水","lab_section_zh":"环境分析实验室 Gdynia"},{"_id":"6a7d76396040ebab2620d479","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 4000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 4000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Zawiesiny ogólne\nZakres (2,0 – 4000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, woda do spozycia przez ludzi, scieki Zawiesiny ogolne\nZakres (2,0 – 4000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":514,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 4000) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Total suspended solids (TSS) Gravimetric method Environmental Analyses Laboratory Gdynia Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 4000) mg/l"}],"search_zh":"水、生活饮用水、污水 总悬浮物 重量法 环境分析实验室 Gdynia 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、生活饮用水、污水","lab_section_zh":"环境分析实验室 Gdynia"},{"_id":"6a7d76396040ebab2620d47a","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu – BZT5","parameters":[{"name":"Zakres","range":"(1 – 6000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (1 – 6000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (1 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Woda, woda do spozycia przez ludzi, scieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (1 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":515,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Biochemical oxygen demand – BOD5","parameters_en":[{"name":"Range","range":"(1 – 6000) mg/l O2"}],"search_en":"Water, water intended for human consumption, wastewater Biochemical oxygen demand – BOD5 Optical method Environmental Analyses Laboratory Gdynia Range PN-EN ISO 5815-1:2019-12","technique_en":"Optical method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(1 – 6000) mg/l O2"}],"search_zh":"水、生活饮用水、污水 五日生化需氧量（BOD5） 光学法 环境分析实验室 Gdynia 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"水、生活饮用水、污水","lab_section_zh":"环境分析实验室 Gdynia","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a7d76396040ebab2620d47b","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Substancje rozpuszczone","parameters":[{"name":"Zakres","range":"(10 – 10000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje rozpuszczone\nZakres (10 – 10000) mg/l\nMetoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Substancje rozpuszczone\nZakres (10 – 10000) mg/l\nMetoda wagowa PN-EN 15216:2022-03 Woda, woda do spozycia przez ludzi, scieki Substancje rozpuszczone\nZakres (10 – 10000) mg/l\nMetoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":516,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Dissolved solids","parameters_en":[{"name":"Range","range":"(10 – 10000) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Dissolved solids Gravimetric method Environmental Analyses Laboratory Gdynia Range PN-EN 15216:2022-03","technique_en":"Gravimetric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(10 – 10000) mg/l"}],"search_zh":"水、生活饮用水、污水 溶解性固体 重量法 环境分析实验室 Gdynia 范围 PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"水、生活饮用水、污水","lab_section_zh":"环境分析实验室 Gdynia","methodology_zh":"溶解性固体"},{"_id":"6a7d76396040ebab2620d47c","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie substancji ekstrahujących się eterem naftowym","parameters":[{"name":"Zakres","range":"(5 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym\nZakres (5 – 1000) mg/l\nMetoda wagowa","reference":"PB-196 wyd. II z dn. 10.05.2018","norm_bases":["PB-196 wyd. II z dn. 10.05.2018"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie substancji ekstrahujących się eterem naftowym\nZakres (5 – 1000) mg/l\nMetoda wagowa PB-196 wyd. II z dn. 10.05.2018 Woda, woda do spozycia przez ludzi, scieki Stezenie substancji ekstrahujacych sie eterem naftowym\nZakres (5 – 1000) mg/l\nMetoda wagowa PB-196 wyd. II z dn. 10.05.2018","categories":["water"],"row_index":517,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Concentration of substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(5 – 1000) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Concentration of substances extractable with petroleum ether Gravimetric method Environmental Analyses Laboratory Gdynia Range PB-196 wyd. II z dn. 10.05.2018","technique_en":"Gravimetric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(5 – 1000) mg/l"}],"search_zh":"水、生活饮用水、污水 石油醚可萃取物浓度 重量法 环境分析实验室 Gdynia 范围 PB-196 wyd. II z dn. 10.05.2018","technique_zh":"重量法","test_object_zh":"水、生活饮用水、污水","lab_section_zh":"环境分析实验室 Gdynia","methodology_zh":"石油醚可萃取物浓度"},{"_id":"6a7d76396040ebab2620d47d","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,00 – 10000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,00 – 10000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie chlorków\nZakres (5,00 – 10000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, woda do spozycia przez ludzi, scieki Stezenie chlorkow\nZakres (5,00 – 10000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":518,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,00 – 10000) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Chloride concentration Titrimetric method Environmental Analyses Laboratory Gdynia Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,00 – 10000) mg/l"}],"search_zh":"水、生活饮用水、污水 氯化物浓度 滴定法 环境分析实验室 Gdynia 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、污水","lab_section_zh":"环境分析实验室 Gdynia"},{"_id":"6a7d76396040ebab2620d47e","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie fosforanów","parameters":[{"name":"Zakres","range":"(0,03 – 15,3) mg/l"},{"name":"Zawartość fosforu całkowitego"},{"name":"Zakres","range":"(0,05 – 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforanów\nZakres:\nZakres (0,03 – 15,3) mg/l\nZawartość fosforu całkowitego\nZakres (0,05 – 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-127 wyd. I z dn. 15.06.2011 | na podstawie testu MERCK 1.14848.0001","norm_bases":["PB-127 wyd. I z dn. 15.06.2011","na podstawie testu MERCK 1.14848.0001"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie fosforanów\nZakres:\nZakres (0,03 – 15,3) mg/l\nZawartość fosforu całkowitego\nZakres (0,05 – 5,0) mg/l\nMetoda spektrofotometryczna PB-127 wyd. I z dn. 15.06.2011 | na podstawie testu MERCK 1.14848.0001 Woda, woda do spozycia przez ludzi, scieki Stezenie fosforanow\nZakres:\nZakres (0,03 – 15,3) mg/l\nZawartosc fosforu calkowitego\nZakres (0,05 – 5,0) mg/l\nMetoda spektrofotometryczna PB-127 wyd. I z dn. 15.06.2011 | na podstawie testu MERCK 1.14848.0001","categories":["water"],"row_index":519,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Phosphate concentration","parameters_en":[{"name":"Range","range":"(0,03 – 15,3) mg/l"},{"name":"Total phosphorus content"},{"name":"Range","range":"(0,05 – 5,0) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Phosphate concentration Spectrophotometric method Environmental Analyses Laboratory Gdynia Range Total phosphorus content Range PB-127 wyd. I z dn. 15.06.2011 | na podstawie testu MERCK 1.14848.0001","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,03 – 15,3) mg/l"},{"name":"总磷含量"},{"name":"范围","range":"(0,05 – 5,0) mg/l"}],"search_zh":"水、生活饮用水、污水 磷酸盐浓度 分光光度法 环境分析实验室 Gdynia 范围 总磷含量 范围 PB-127 wyd. I z dn. 15.06.2011 | na podstawie testu MERCK 1.14848.0001","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水","lab_section_zh":"环境分析实验室 Gdynia","methodology_zh":"磷酸盐浓度"},{"_id":"6a7d76396040ebab2620d47f","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(5,0 – 250) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczanów\nZakres (5,0 – 250) mg/l\nMetoda spektrofotometryczna","reference":"PB-128 wyd. I z dn. 15.06.2011 | na podstawie testu MERCK 1.14548.0001","norm_bases":["PB-128 wyd. I z dn. 15.06.2011","na podstawie testu MERCK 1.14548.0001"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie siarczanów\nZakres (5,0 – 250) mg/l\nMetoda spektrofotometryczna PB-128 wyd. I z dn. 15.06.2011 | na podstawie testu MERCK 1.14548.0001 Woda, woda do spozycia przez ludzi, scieki Stezenie siarczanow\nZakres (5,0 – 250) mg/l\nMetoda spektrofotometryczna PB-128 wyd. I z dn. 15.06.2011 | na podstawie testu MERCK 1.14548.0001","categories":["water"],"row_index":520,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(5,0 – 250) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Sulfate concentration Spectrophotometric method Environmental Analyses Laboratory Gdynia Range PB-128 wyd. I z dn. 15.06.2011 | na podstawie testu MERCK 1.14548.0001","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 250) mg/l"}],"search_zh":"水、生活饮用水、污水 硫酸盐浓度 分光光度法 环境分析实验室 Gdynia 范围 PB-128 wyd. I z dn. 15.06.2011 | na podstawie testu MERCK 1.14548.0001","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水","lab_section_zh":"环境分析实验室 Gdynia"},{"_id":"6a7d76396040ebab2620d480","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie cyjanków wolnych i związanych","parameters":[{"name":"Zakres","range":"(0,005 – 0,500) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie cyjanków wolnych i związanych\nZakres (0,005 – 0,500) mg/l\nMetoda spektrofotometryczna","reference":"PB-129 wyd. I z dn. 15.06.2011 | na podstawie testu MERCK 1.09701.0001","norm_bases":["PB-129 wyd. I z dn. 15.06.2011","na podstawie testu MERCK 1.09701.0001"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie cyjanków wolnych i związanych\nZakres (0,005 – 0,500) mg/l\nMetoda spektrofotometryczna PB-129 wyd. I z dn. 15.06.2011 | na podstawie testu MERCK 1.09701.0001 Woda, woda do spozycia przez ludzi, scieki Stezenie cyjankow wolnych i zwiazanych\nZakres (0,005 – 0,500) mg/l\nMetoda spektrofotometryczna PB-129 wyd. I z dn. 15.06.2011 | na podstawie testu MERCK 1.09701.0001","categories":["water"],"row_index":521,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Free and combined cyanide concentration","parameters_en":[{"name":"Range","range":"(0,005 – 0,500) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Free and combined cyanide concentration Spectrophotometric method Environmental Analyses Laboratory Gdynia Range PB-129 wyd. I z dn. 15.06.2011 | na podstawie testu MERCK 1.09701.0001","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,005 – 0,500) mg/l"}],"search_zh":"水、生活饮用水、污水 分光光度法 环境分析实验室 Gdynia 范围 PB-129 wyd. I z dn. 15.06.2011 | na podstawie testu MERCK 1.09701.0001","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水","lab_section_zh":"环境分析实验室 Gdynia"},{"_id":"6a7d76396040ebab2620d481","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie ogólnego węgla organicznego (OWO)","parameters":[{"name":"Zakres","range":"(1,50 – 1000) mg/l"}],"technique":"Metoda spektrometrii w zakresie podczerwieni (IR)","techniques":["Metoda spektrometrii w zakresie podczerwieni (IR)"],"computed":[],"activity":"Stężenie ogólnego węgla organicznego (OWO)\nZakres (1,50 – 1000) mg/l\nMetoda spektrometrii w zakresie podczerwieni (IR)","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie ogólnego węgla organicznego (OWO)\nZakres (1,50 – 1000) mg/l\nMetoda spektrometrii w zakresie podczerwieni (IR) PN-EN 1484:1999 Woda, woda do spozycia przez ludzi, scieki Stezenie ogolnego wegla organicznego (OWO)\nZakres (1,50 – 1000) mg/l\nMetoda spektrometrii w zakresie podczerwieni (IR) PN-EN 1484:1999","categories":["water"],"row_index":522,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Total organic carbon concentration (TOC)","parameters_en":[{"name":"Range","range":"(1,50 – 1000) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Total organic carbon concentration (TOC) Spectrometry method in the infrared range (IR) Environmental Analyses Laboratory Gdynia Range PN-EN 1484:1999","technique_en":"Spectrometry method in the infrared range (IR)","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(1,50 – 1000) mg/l"}],"search_zh":"水、生活饮用水、污水 总有机碳浓度（TOC） 红外光谱法（IR） 环境分析实验室 Gdynia 范围 PN-EN 1484:1999","test_object_zh":"水、生活饮用水、污水","lab_section_zh":"环境分析实验室 Gdynia","methodology_zh":"总有机碳浓度（TOC）","technique_zh":"红外光谱法（IR）"},{"_id":"6a7d76396040ebab2620d482","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie detergentów anionowych (anionowych substancji powierzchniowo czynnych – ASPC)","parameters":[{"name":"Zakres","range":"(0,05 – 50,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie detergentów anionowych (anionowych substancji powierzchniowo czynnych – ASPC)\nZakres (0,05 – 50,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 903:2002","norm_bases":["PN-EN 903:2002"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie detergentów anionowych (anionowych substancji powierzchniowo czynnych – ASPC)\nZakres (0,05 – 50,0) mg/l\nMetoda spektrofotometryczna PN-EN 903:2002 Woda, woda do spozycia przez ludzi, scieki Stezenie detergentow anionowych (anionowych substancji powierzchniowo czynnych – ASPC)\nZakres (0,05 – 50,0) mg/l\nMetoda spektrofotometryczna PN-EN 903:2002","categories":["water"],"row_index":523,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Anionic detergent concentration (anionic surfactants – ASPC)","parameters_en":[{"name":"Range","range":"(0,05 – 50,0) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Anionic detergent concentration (anionic surfactants – ASPC) Spectrophotometric method Environmental Analyses Laboratory Gdynia Range PN-EN 903:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,05 – 50,0) mg/l"}],"search_zh":"水、生活饮用水、污水 阴离子洗涤剂（阴离子表面活性物质 ASPC）浓度 分光光度法 环境分析实验室 Gdynia 范围 PN-EN 903:2002","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水","lab_section_zh":"环境分析实验室 Gdynia","methodology_zh":"阴离子洗涤剂（阴离子表面活性物质 ASPC）浓度"},{"_id":"6a7d76396040ebab2620d483","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Indeks oleju mineralnego","parameters":[{"name":"Zakres","range":"(0,1 – 100) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Indeks oleju mineralnego\nZakres (0,1 – 100) mg/l\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Indeks oleju mineralnego\nZakres (0,1 – 100) mg/l\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PN-EN ISO 9377-2:2003 Woda, woda do spozycia przez ludzi, scieki Indeks oleju mineralnego\nZakres (0,1 – 100) mg/l\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":524,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Mineral oil index","parameters_en":[{"name":"Range","range":"(0,1 – 100) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Mineral oil index Gas chromatography with mass spectrometry detection (GC-MS) Environmental Analyses Laboratory Gdynia Range PN-EN ISO 9377-2:2003","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,1 – 100) mg/l"}],"search_zh":"水、生活饮用水、污水 矿物油指数 气相色谱-质谱法（GC-MS） 环境分析实验室 Gdynia 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"水、生活饮用水、污水","lab_section_zh":"环境分析实验室 Gdynia","methodology_zh":"矿物油指数"},{"_id":"6a7d76396040ebab2620d484","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr","parameters":[{"name":"Zakres","range":"(5,00 – 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (5,00 – 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (5,00 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, woda do spozycia przez ludzi, scieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (5,00 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":525,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Chemical oxygen demand – COD-Cr","parameters_en":[{"name":"Range","range":"(5,00 – 10000) mg/l O2"}],"search_en":"Water, water intended for human consumption, wastewater Chemical oxygen demand – COD-Cr Spectrophotometric method Environmental Analyses Laboratory Gdynia Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(5,00 – 10000) mg/l O2"}],"search_zh":"水、生活饮用水、污水 化学需氧量（COD-Cr） 分光光度法 环境分析实验室 Gdynia 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水","lab_section_zh":"环境分析实验室 Gdynia","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a7d76396040ebab2620d485","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie pestycydów chloroorganicznych","parameters":[{"name":"HCB","range":"(0,010 – 0,2) μg/l"},{"name":"alfa HCH","range":"(0,010 – 0,2) μg/l"},{"name":"beta HCH","range":"(0,010 – 0,2) μg/l"},{"name":"gamma HCH","range":"(0,010 – 0,2) μg/l"},{"name":"delta HCH","range":"(0,010 – 0,2) μg/l"},{"name":"heptachlor","range":"(0,010 – 0,2) μg/l"},{"name":"epoksyd heptachloru","range":"(0,010 – 0,2) μg/l"},{"name":"aldryna","range":"(0,010 – 0,2) μg/l"},{"name":"dieldryna","range":"(0,010 – 0,2) μg/l"},{"name":"endryna","range":"(0,010 – 0,2) μg/l"},{"name":"izodryna","range":"(0,010 – 0,2) μg/l"},{"name":"cis chlordan","range":"(0,010 – 0,2) μg/l"},{"name":"trans chlordan","range":"(0,010 – 0,2) μg/l"},{"name":"op’DDE","range":"(0,010 – 0,2) μg/l"},{"name":"pp’DDE","range":"(0,010 – 0,2) μg/l"},{"name":"op’DDD","range":"(0,010 – 0,2) μg/l"},{"name":"pp’DDD","range":"(0,010 – 0,2) μg/l"},{"name":"op’DDT","range":"(0,010 – 0,2) μg/l"},{"name":"pp’DDT","range":"(0,010 – 0,2) μg/l"},{"name":"Suma pestycydów chloroorganicznych (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Stężenie pestycydów chloroorganicznych\nZakres:\nHCB (0,010 – 0,2) μg/l\nalfa HCH (0,010 – 0,2) μg/l\nbeta HCH (0,010 – 0,2) μg/l\ngamma HCH (0,010 – 0,2) μg/l\ndelta HCH (0,010 – 0,2) μg/l\nheptachlor (0,010 – 0,2) μg/l\nepoksyd heptachloru (0,010 – 0,2) μg/l\naldryna (0,010 – 0,2) μg/l\ndieldryna (0,010 – 0,2) μg/l\nendryna (0,010 – 0,2) μg/l\nizodryna (0,010 – 0,2) μg/l\ncis chlordan (0,010 – 0,2) μg/l\ntrans chlordan (0,010 – 0,2) μg/l\nop’DDE (0,010 – 0,2) μg/l\npp’DDE (0,010 – 0,2) μg/l\nop’DDD (0,010 – 0,2) μg/l\npp’DDD (0,010 – 0,2) μg/l\nop’DDT (0,010 – 0,2) μg/l\npp’DDT (0,010 – 0,2) μg/l\nSuma pestycydów chloroorganicznych (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PN-EN ISO 6468:2002","norm_bases":["PN-EN ISO 6468:2002"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie pestycydów chloroorganicznych\nZakres:\nHCB (0,010 – 0,2) μg/l\nalfa HCH (0,010 – 0,2) μg/l\nbeta HCH (0,010 – 0,2) μg/l\ngamma HCH (0,010 – 0,2) μg/l\ndelta HCH (0,010 – 0,2) μg/l\nheptachlor (0,010 – 0,2) μg/l\nepoksyd heptachloru (0,010 – 0,2) μg/l\naldryna (0,010 – 0,2) μg/l\ndieldryna (0,010 – 0,2) μg/l\nendryna (0,010 – 0,2) μg/l\nizodryna (0,010 – 0,2) μg/l\ncis chlordan (0,010 – 0,2) μg/l\ntrans chlordan (0,010 – 0,2) μg/l\nop’DDE (0,010 – 0,2) μg/l\npp’DDE (0,010 – 0,2) μg/l\nop’DDD (0,010 – 0,2) μg/l\npp’DDD (0,010 – 0,2) μg/l\nop’DDT (0,010 – 0,2) μg/l\npp’DDT (0,010 – 0,2) μg/l\nSuma pestycydów chloroorganicznych (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PN-EN ISO 6468:2002 Woda, woda do spozycia przez ludzi, scieki Stezenie pestycydow chloroorganicznych\nZakres:\nHCB (0,010 – 0,2) μg/l\nalfa HCH (0,010 – 0,2) μg/l\nbeta HCH (0,010 – 0,2) μg/l\ngamma HCH (0,010 – 0,2) μg/l\ndelta HCH (0,010 – 0,2) μg/l\nheptachlor (0,010 – 0,2) μg/l\nepoksyd heptachloru (0,010 – 0,2) μg/l\naldryna (0,010 – 0,2) μg/l\ndieldryna (0,010 – 0,2) μg/l\nendryna (0,010 – 0,2) μg/l\nizodryna (0,010 – 0,2) μg/l\ncis chlordan (0,010 – 0,2) μg/l\ntrans chlordan (0,010 – 0,2) μg/l\nop’DDE (0,010 – 0,2) μg/l\npp’DDE (0,010 – 0,2) μg/l\nop’DDD (0,010 – 0,2) μg/l\npp’DDD (0,010 – 0,2) μg/l\nop’DDT (0,010 – 0,2) μg/l\npp’DDT (0,010 – 0,2) μg/l\nSuma pestycydow chloroorganicznych (z obliczen)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PN-EN ISO 6468:2002","categories":["water"],"row_index":526,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Organochlorine pesticide concentration","parameters_en":[{"name":"HCB","range":"(0,010 – 0,2) μg/l"},{"name":"alpha HCH","range":"(0,010 – 0,2) μg/l"},{"name":"beta HCH","range":"(0,010 – 0,2) μg/l"},{"name":"gamma HCH","range":"(0,010 – 0,2) μg/l"},{"name":"delta HCH","range":"(0,010 – 0,2) μg/l"},{"name":"heptachlor","range":"(0,010 – 0,2) μg/l"},{"name":"heptachlor epoxide","range":"(0,010 – 0,2) μg/l"},{"name":"aldrin","range":"(0,010 – 0,2) μg/l"},{"name":"dieldrin","range":"(0,010 – 0,2) μg/l"},{"name":"endrin","range":"(0,010 – 0,2) μg/l"},{"name":"isodrin","range":"(0,010 – 0,2) μg/l"},{"name":"cis chlordane","range":"(0,010 – 0,2) μg/l"},{"name":"trans chlordane","range":"(0,010 – 0,2) μg/l"},{"name":"op’DDE","range":"(0,010 – 0,2) μg/l"},{"name":"pp’DDE","range":"(0,010 – 0,2) μg/l"},{"name":"op’DDD","range":"(0,010 – 0,2) μg/l"},{"name":"pp’DDD","range":"(0,010 – 0,2) μg/l"},{"name":"op’DDT","range":"(0,010 – 0,2) μg/l"},{"name":"pp’DDT","range":"(0,010 – 0,2) μg/l"},{"name":"Sum of organochlorine pesticides (calculated)"}],"search_en":"Water, water intended for human consumption, wastewater Organochlorine pesticide concentration Gas chromatography with mass spectrometry detection (GC-MS) Environmental Analyses Laboratory Gdynia HCB alpha HCH beta HCH gamma HCH delta HCH heptachlor heptachlor epoxide aldrin dieldrin endrin isodrin cis chlordane trans chlordane op’DDE pp’DDE op’DDD pp’DDD op’DDT pp’DDT Sum of organochlorine pesticides (calculated) PN-EN ISO 6468:2002","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Water, water intended for human consumption, wastewater","search_zh":"水、生活饮用水、污水 有机氯农药浓度 气相色谱-质谱法（GC-MS） 环境分析实验室 Gdynia 六氯苯（HCB） β-六六六 γ-六六六 七氯 环氧七氯 艾氏剂 狄氏剂 异狄氏剂 异艾氏剂 有机氯农药总量（由计算得出） PN-EN ISO 6468:2002","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"水、生活饮用水、污水","lab_section_zh":"环境分析实验室 Gdynia","parameters_zh":[{"name":"六氯苯（HCB）","range":"(0,010 – 0,2) μg/l"},{"name":"alfa HCH","range":"(0,010 – 0,2) μg/l"},{"name":"β-六六六","range":"(0,010 – 0,2) μg/l"},{"name":"γ-六六六","range":"(0,010 – 0,2) μg/l"},{"name":"delta HCH","range":"(0,010 – 0,2) μg/l"},{"name":"七氯","range":"(0,010 – 0,2) μg/l"},{"name":"环氧七氯","range":"(0,010 – 0,2) μg/l"},{"name":"艾氏剂","range":"(0,010 – 0,2) μg/l"},{"name":"狄氏剂","range":"(0,010 – 0,2) μg/l"},{"name":"异狄氏剂","range":"(0,010 – 0,2) μg/l"},{"name":"异艾氏剂","range":"(0,010 – 0,2) μg/l"},{"name":"cis chlordan","range":"(0,010 – 0,2) μg/l"},{"name":"trans chlordan","range":"(0,010 – 0,2) μg/l"},{"name":"op’DDE","range":"(0,010 – 0,2) μg/l"},{"name":"pp’DDE","range":"(0,010 – 0,2) μg/l"},{"name":"op’DDD","range":"(0,010 – 0,2) μg/l"},{"name":"pp’DDD","range":"(0,010 – 0,2) μg/l"},{"name":"op’DDT","range":"(0,010 – 0,2) μg/l"},{"name":"pp’DDT","range":"(0,010 – 0,2) μg/l"},{"name":"有机氯农药总量（由计算得出）"}],"methodology_zh":"有机氯农药浓度"},{"_id":"6a7d76396040ebab2620d486","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie detergentów anionowych (anionowych substancji powierzchniowo czynnych – ASPC)","parameters":[{"name":"Zakres","range":"(0,10 – 20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie detergentów anionowych (anionowych substancji powierzchniowo czynnych – ASPC)\nZakres (0,10 – 20) mg/l\nMetoda spektrofotometryczna","reference":"PB-379 wyd. I z dn. 10.05.2018 | na podstawie testu kuwetego MERCK 1.02552.0001","norm_bases":["PB-379 wyd. I z dn. 10.05.2018","na podstawie testu kuwetego MERCK 1.02552.0001"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie detergentów anionowych (anionowych substancji powierzchniowo czynnych – ASPC)\nZakres (0,10 – 20) mg/l\nMetoda spektrofotometryczna PB-379 wyd. I z dn. 10.05.2018 | na podstawie testu kuwetego MERCK 1.02552.0001 Woda, woda do spozycia przez ludzi, scieki Stezenie detergentow anionowych (anionowych substancji powierzchniowo czynnych – ASPC)\nZakres (0,10 – 20) mg/l\nMetoda spektrofotometryczna PB-379 wyd. I z dn. 10.05.2018 | na podstawie testu kuwetego MERCK 1.02552.0001","categories":["water"],"row_index":527,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Anionic detergent concentration (anionic surfactants – ASPC)","parameters_en":[{"name":"Range","range":"(0,10 – 20) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Anionic detergent concentration (anionic surfactants – ASPC) Spectrophotometric method Environmental Analyses Laboratory Gdynia Range PB-379 wyd. I z dn. 10.05.2018 | na podstawie testu kuwetego MERCK 1.02552.0001","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,10 – 20) mg/l"}],"search_zh":"水、生活饮用水、污水 阴离子洗涤剂（阴离子表面活性物质 ASPC）浓度 分光光度法 环境分析实验室 Gdynia 范围 PB-379 wyd. I z dn. 10.05.2018 | na podstawie testu kuwetego MERCK 1.02552.0001","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水","lab_section_zh":"环境分析实验室 Gdynia","methodology_zh":"阴离子洗涤剂（阴离子表面活性物质 ASPC）浓度"},{"_id":"6a7d76396040ebab2620d487","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie detergentów niejonowych (niejonowych substancji powierzchniowo czynnych, surfaktantów niejonowych)","parameters":[{"name":"Zakres","range":"(0,3 – 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie detergentów niejonowych (niejonowych substancji powierzchniowo czynnych, surfaktantów niejonowych)\nZakres (0,3 – 50) mg/l\nMetoda spektrofotometryczna","reference":"PB-477 wyd. I z dn. 01.04.2021 | na podstawie testu NANOCOLOR 985047","norm_bases":["PB-477 wyd. I z dn. 01.04.2021","na podstawie testu NANOCOLOR 985047"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie detergentów niejonowych (niejonowych substancji powierzchniowo czynnych, surfaktantów niejonowych)\nZakres (0,3 – 50) mg/l\nMetoda spektrofotometryczna PB-477 wyd. I z dn. 01.04.2021 | na podstawie testu NANOCOLOR 985047 Woda, woda do spozycia przez ludzi, scieki Stezenie detergentow niejonowych (niejonowych substancji powierzchniowo czynnych, surfaktantow niejonowych)\nZakres (0,3 – 50) mg/l\nMetoda spektrofotometryczna PB-477 wyd. I z dn. 01.04.2021 | na podstawie testu NANOCOLOR 985047","categories":["water"],"row_index":528,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Non-ionic detergent concentration (non-ionic surface active substances, non-ionic surfactants)","parameters_en":[{"name":"Range","range":"(0,3 – 50) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Non-ionic detergent concentration (non-ionic surface active substances, non-ionic surfactants) Spectrophotometric method Environmental Analyses Laboratory Gdynia Range PB-477 wyd. I z dn. 01.04.2021 | na podstawie testu NANOCOLOR 985047","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,3 – 50) mg/l"}],"search_zh":"水、生活饮用水、污水 分光光度法 环境分析实验室 Gdynia 范围 PB-477 wyd. I z dn. 01.04.2021 | na podstawie testu NANOCOLOR 985047","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水","lab_section_zh":"环境分析实验室 Gdynia"},{"_id":"6a7d76396040ebab2620d488","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie siarczków","parameters":[{"name":"Zakres","range":"(0,05 – 1,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczków\nZakres (0,05 – 1,5) mg/l\nMetoda spektrofotometryczna","reference":"PB-476 wyd. I z dn. 01.04.2021 | na podstawie testu MERCK 1.14779.0001","norm_bases":["PB-476 wyd. I z dn. 01.04.2021","na podstawie testu MERCK 1.14779.0001"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie siarczków\nZakres (0,05 – 1,5) mg/l\nMetoda spektrofotometryczna PB-476 wyd. I z dn. 01.04.2021 | na podstawie testu MERCK 1.14779.0001 Woda, woda do spozycia przez ludzi, scieki Stezenie siarczkow\nZakres (0,05 – 1,5) mg/l\nMetoda spektrofotometryczna PB-476 wyd. I z dn. 01.04.2021 | na podstawie testu MERCK 1.14779.0001","categories":["water"],"row_index":529,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Sulfide concentration","parameters_en":[{"name":"Range","range":"(0,05 – 1,5) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Sulfide concentration Spectrophotometric method Environmental Analyses Laboratory Gdynia Range PB-476 wyd. I z dn. 01.04.2021 | na podstawie testu MERCK 1.14779.0001","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,05 – 1,5) mg/l"}],"search_zh":"水、生活饮用水、污水 硫化物浓度 分光光度法 环境分析实验室 Gdynia 范围 PB-476 wyd. I z dn. 01.04.2021 | na podstawie testu MERCK 1.14779.0001","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水","lab_section_zh":"环境分析实验室 Gdynia","methodology_zh":"硫化物浓度"},{"_id":"6a7d76396040ebab2620d489","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie formaldehydu","parameters":[{"name":"Zakres","range":"(0,1 – 8,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie formaldehydu\nZakres (0,1 – 8,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-478 wyd. I z dn. 23.06.2021 | na podstawie testu NANOCOLOR 985041","norm_bases":["PB-478 wyd. I z dn. 23.06.2021","na podstawie testu NANOCOLOR 985041"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie formaldehydu\nZakres (0,1 – 8,0) mg/l\nMetoda spektrofotometryczna PB-478 wyd. I z dn. 23.06.2021 | na podstawie testu NANOCOLOR 985041 Woda, woda do spozycia przez ludzi, scieki Stezenie formaldehydu\nZakres (0,1 – 8,0) mg/l\nMetoda spektrofotometryczna PB-478 wyd. I z dn. 23.06.2021 | na podstawie testu NANOCOLOR 985041","categories":["water"],"row_index":530,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Formaldehyde concentration","parameters_en":[{"name":"Range","range":"(0,1 – 8,0) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Formaldehyde concentration Spectrophotometric method Environmental Analyses Laboratory Gdynia Range PB-478 wyd. I z dn. 23.06.2021 | na podstawie testu NANOCOLOR 985041","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,1 – 8,0) mg/l"}],"search_zh":"水、生活饮用水、污水 甲醛浓度 分光光度法 环境分析实验室 Gdynia 范围 PB-478 wyd. I z dn. 23.06.2021 | na podstawie testu NANOCOLOR 985041","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水","lab_section_zh":"环境分析实验室 Gdynia","methodology_zh":"甲醛浓度"},{"_id":"6a7d76396040ebab2620d48a","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,50 – 10) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,50 – 10) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Indeks nadmanganianowy\nZakres (0,50 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, woda do spozycia przez ludzi Indeks nadmanganianowy\nZakres (0,50 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":531,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,50 – 10) mg/l O2"}],"search_en":"Water, water intended for human consumption Permanganate index Titrimetric method Environmental Analyses Laboratory Gdynia Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,50 – 10) mg/l O2"}],"search_zh":"水、生活饮用水 高锰酸盐指数 滴定法 环境分析实验室 Gdynia 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","lab_section_zh":"环境分析实验室 Gdynia"},{"_id":"6a7d76396040ebab2620d48b","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,06 – 3,86) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,06 – 3,86) mg/l\nMetoda spektrofotometryczna","reference":"PB-124 wyd. I z dn. 15.06.2011 | na podstawie testu MERCK 1.14752.0001","norm_bases":["PB-124 wyd. I z dn. 15.06.2011","na podstawie testu MERCK 1.14752.0001"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,06 – 3,86) mg/l\nMetoda spektrofotometryczna PB-124 wyd. I z dn. 15.06.2011 | na podstawie testu MERCK 1.14752.0001 Woda, woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,06 – 3,86) mg/l\nMetoda spektrofotometryczna PB-124 wyd. I z dn. 15.06.2011 | na podstawie testu MERCK 1.14752.0001","categories":["water"],"row_index":532,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,06 – 3,86) mg/l"}],"search_en":"Water, water intended for human consumption Ammonium ion concentration Spectrophotometric method Environmental Analyses Laboratory Gdynia Range PB-124 wyd. I z dn. 15.06.2011 | na podstawie testu MERCK 1.14752.0001","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,06 – 3,86) mg/l"}],"search_zh":"水、生活饮用水 铵离子浓度 分光光度法 环境分析实验室 Gdynia 范围 PB-124 wyd. I z dn. 15.06.2011 | na podstawie testu MERCK 1.14752.0001","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"环境分析实验室 Gdynia"},{"_id":"6a7d76396040ebab2620d48c","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 – 70) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (5 – 70) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 metoda C +Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 metoda C +Ap1:2015-06"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Barwa\nZakres (5 – 70) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C +Ap1:2015-06 Woda, woda do spozycia przez ludzi Barwa\nZakres (5 – 70) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C +Ap1:2015-06","categories":["water"],"row_index":533,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 – 70) mg/l Pt"}],"search_en":"Water, water intended for human consumption Colour Spectrophotometric method Environmental Analyses Laboratory Gdynia Range PN-EN ISO 7887:2012 metoda C +Ap1:2015-06","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 70) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 分光光度法 环境分析实验室 Gdynia 范围 PN-EN ISO 7887:2012 metoda C +Ap1:2015-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"环境分析实验室 Gdynia"},{"_id":"6a7d76396040ebab2620d48d","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,20 – 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,20 – 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Mętność\nZakres (0,20 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, woda do spozycia przez ludzi Metnosc\nZakres (0,20 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":534,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,20 – 100) NTU"}],"search_en":"Water, water intended for human consumption Turbidity Nephelometric method Environmental Analyses Laboratory Gdynia Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 – 100) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 环境分析实验室 Gdynia 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水","lab_section_zh":"环境分析实验室 Gdynia"},{"_id":"6a7d76396040ebab2620d48e","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Zasadowość ogólna","parameters":[{"name":"Zakres","range":"(0,40 – 20) mmol/l"},{"name":"Wodorowęglany"},{"name":"Zakres","range":"(24,4 – 1220) mg/l HCO3-"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zasadowość ogólna\nZakres:\nZakres (0,40 – 20) mmol/l\nWodorowęglany\nZakres (24,4 – 1220) mg/l HCO3-\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001 +Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001 +Ap1:2004"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Zasadowość ogólna\nZakres:\nZakres (0,40 – 20) mmol/l\nWodorowęglany\nZakres (24,4 – 1220) mg/l HCO3-\nMetoda miareczkowa PN-EN ISO 9963-1:2001 +Ap1:2004 Woda, woda do spozycia przez ludzi Zasadowosc ogolna\nZakres:\nZakres (0,40 – 20) mmol/l\nWodoroweglany\nZakres (24,4 – 1220) mg/l HCO3-\nMetoda miareczkowa PN-EN ISO 9963-1:2001 +Ap1:2004","categories":["water"],"row_index":535,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Total alkalinity","parameters_en":[{"name":"Range","range":"(0,40 – 20) mmol/l"},{"name":"Bicarbonates"},{"name":"Range","range":"(24,4 – 1220) mg/l HCO3-"}],"search_en":"Water, water intended for human consumption Total alkalinity Titrimetric method Environmental Analyses Laboratory Gdynia Range Bicarbonates Range PN-EN ISO 9963-1:2001 +Ap1:2004","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,40 – 20) mmol/l"},{"name":"碳酸氢盐"},{"name":"范围","range":"(24,4 – 1220) mg/l HCO3-"}],"search_zh":"水、生活饮用水 总碱度 滴定法 环境分析实验室 Gdynia 范围 碳酸氢盐 范围 PN-EN ISO 9963-1:2001 +Ap1:2004","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","lab_section_zh":"环境分析实验室 Gdynia","methodology_zh":"总碱度"},{"_id":"6a7d76396040ebab2620d48f","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie bromianów","parameters":[{"name":"Zakres","range":"(3 – 20,0) μg/l"}],"technique":"Metoda chromatografii jonowej z detekcją spektrofotometryczną (IC-UV/Vis)","techniques":["Metoda chromatografii jonowej z detekcją spektrofotometryczną (IC-UV/Vis)"],"computed":[],"activity":"Stężenie bromianów\nZakres (3 – 20,0) μg/l\nMetoda chromatografii jonowej z detekcją spektrofotometryczną (IC-UV/Vis)","reference":"PN-EN ISO 11206:2013-07","norm_bases":["PN-EN ISO 11206:2013-07"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie bromianów\nZakres (3 – 20,0) μg/l\nMetoda chromatografii jonowej z detekcją spektrofotometryczną (IC-UV/Vis) PN-EN ISO 11206:2013-07 Woda, woda do spozycia przez ludzi Stezenie bromianow\nZakres (3 – 20,0) μg/l\nMetoda chromatografii jonowej z detekcja spektrofotometryczna (IC-UV/Vis) PN-EN ISO 11206:2013-07","categories":["water"],"row_index":536,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Bromate concentration","parameters_en":[{"name":"Range","range":"(3 – 20,0) μg/l"}],"search_en":"Water, water intended for human consumption Bromate concentration Ion chromatography with spectrophotometric detection (IC-UV/Vis) Environmental Analyses Laboratory Gdynia Range PN-EN ISO 11206:2013-07","technique_en":"Ion chromatography with spectrophotometric detection (IC-UV/Vis)","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(3 – 20,0) μg/l"}],"search_zh":"水、生活饮用水 溴酸盐浓度 离子色谱-分光光度检测法（IC-UV/Vis） 环境分析实验室 Gdynia 范围 PN-EN ISO 11206:2013-07","test_object_zh":"水、生活饮用水","lab_section_zh":"环境分析实验室 Gdynia","methodology_zh":"溴酸盐浓度","technique_zh":"离子色谱-分光光度检测法（IC-UV/Vis）"},{"_id":"6a7d76396040ebab2620d490","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie akryloamidu","parameters":[{"name":"Zakres","range":"(0,05 – 5,0) μg/l"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)"],"computed":[],"activity":"Stężenie akryloamidu\nZakres (0,05 – 5,0) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","reference":"PB-403 wyd. I z dn. 25.06.2020","norm_bases":["PB-403 wyd. I z dn. 25.06.2020"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie akryloamidu\nZakres (0,05 – 5,0) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS) PB-403 wyd. I z dn. 25.06.2020 Woda, woda do spozycia przez ludzi Stezenie akryloamidu\nZakres (0,05 – 5,0) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS-MS) PB-403 wyd. I z dn. 25.06.2020","categories":["water"],"row_index":537,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Acrylamide concentration","parameters_en":[{"name":"Range","range":"(0,05 – 5,0) μg/l"}],"search_en":"Water, water intended for human consumption Acrylamide concentration High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS-MS) Environmental Analyses Laboratory Gdynia Range PB-403 wyd. I z dn. 25.06.2020","technique_en":"High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS-MS)","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,05 – 5,0) μg/l"}],"search_zh":"水、生活饮用水 丙烯酰胺浓度 高效液相色谱-串联质谱法（LC-MS-MS） 环境分析实验室 Gdynia 范围 PB-403 wyd. I z dn. 25.06.2020","test_object_zh":"水、生活饮用水","lab_section_zh":"环境分析实验室 Gdynia","methodology_zh":"丙烯酰胺浓度","technique_zh":"高效液相色谱-串联质谱法（LC-MS-MS）"},{"_id":"6a7d76396040ebab2620d491","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie pestycydów","parameters":[{"name":"fosforoorganicznych: azinofos etylowy, chlorfenwinfos bromofos etylowy, bifentryna azinofos metylowy, chlorpiryfos etylowy, chloropiryfos metylowy, cyflutryna, cypermetryna, deltametryna, demeton-S-methyl, diazynon, diflufenikan, dimetoat, etion, etoprofos, fenitrotion l, fenpropatryna, fensulfotion, fention, fenwalerat, fluopikolid, forat, fosalon, fosmet, kaptan, karbofenotion, lambda-cyhalotryna, malaokson, malation, mefenpyr dietylowy, mekarbam, metidation, metrybuzyna, mewinfos, oksyfluorofen, paration etylowy, paration metylowy, permetryna, pirymifos etylowy, pirymifos metylowy, procymidon, profetamfos, protiofos, pyrazofos, triadimefon, triadimenol, triazofos, trifloksystrobina"},{"name":"Zakres","range":"(0,05 – 0,5) μg/l"},{"name":"Suma pestycydów fosforoorganicznych (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Stężenie pestycydów\nZakres:\nfosforoorganicznych: azinofos etylowy, chlorfenwinfos bromofos etylowy, bifentryna azinofos metylowy, chlorpiryfos etylowy, chloropiryfos metylowy, cyflutryna, cypermetryna, deltametryna, demeton-S-methyl, diazynon, diflufenikan, dimetoat, etion, etoprofos, fenitrotion l, fenpropatryna, fensulfotion, fention, fenwalerat, fluopikolid, forat, fosalon, fosmet, kaptan, karbofenotion, lambda-cyhalotryna, malaokson, malation, mefenpyr dietylowy, mekarbam, metidation, metrybuzyna, mewinfos, oksyfluorofen, paration etylowy, paration metylowy, permetryna, pirymifos etylowy, pirymifos metylowy, procymidon, profetamfos, protiofos, pyrazofos, triadimefon, triadimenol, triazofos, trifloksystrobina\nZakres (0,05 – 0,5) μg/l\nSuma pestycydów fosforoorganicznych (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PN-EN 12918:2004","norm_bases":["PN-EN 12918:2004"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie pestycydów\nZakres:\nfosforoorganicznych: azinofos etylowy, chlorfenwinfos bromofos etylowy, bifentryna azinofos metylowy, chlorpiryfos etylowy, chloropiryfos metylowy, cyflutryna, cypermetryna, deltametryna, demeton-S-methyl, diazynon, diflufenikan, dimetoat, etion, etoprofos, fenitrotion l, fenpropatryna, fensulfotion, fention, fenwalerat, fluopikolid, forat, fosalon, fosmet, kaptan, karbofenotion, lambda-cyhalotryna, malaokson, malation, mefenpyr dietylowy, mekarbam, metidation, metrybuzyna, mewinfos, oksyfluorofen, paration etylowy, paration metylowy, permetryna, pirymifos etylowy, pirymifos metylowy, procymidon, profetamfos, protiofos, pyrazofos, triadimefon, triadimenol, triazofos, trifloksystrobina\nZakres (0,05 – 0,5) μg/l\nSuma pestycydów fosforoorganicznych (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PN-EN 12918:2004 Woda, woda do spozycia przez ludzi Stezenie pestycydow\nZakres:\nfosforoorganicznych: azinofos etylowy, chlorfenwinfos bromofos etylowy, bifentryna azinofos metylowy, chlorpiryfos etylowy, chloropiryfos metylowy, cyflutryna, cypermetryna, deltametryna, demeton-S-methyl, diazynon, diflufenikan, dimetoat, etion, etoprofos, fenitrotion l, fenpropatryna, fensulfotion, fention, fenwalerat, fluopikolid, forat, fosalon, fosmet, kaptan, karbofenotion, lambda-cyhalotryna, malaokson, malation, mefenpyr dietylowy, mekarbam, metidation, metrybuzyna, mewinfos, oksyfluorofen, paration etylowy, paration metylowy, permetryna, pirymifos etylowy, pirymifos metylowy, procymidon, profetamfos, protiofos, pyrazofos, triadimefon, triadimenol, triazofos, trifloksystrobina\nZakres (0,05 – 0,5) μg/l\nSuma pestycydow fosforoorganicznych (z obliczen)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PN-EN 12918:2004","categories":["water"],"row_index":538,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Pesticide concentration","parameters_en":[{"name":"organophosphorus: azinphos-ethyl, chlorfenvinphos bromophos-ethyl, bifenthrin azinphos-methyl, chlorpyrifos-ethyl, chlorpyrifos-methyl, cyfluthrin, cypermethrin, deltamethrin, demeton-S-methyl, diazinon, diflufenican, dimethoate, ethion, ethoprophos, fenitrothion l, fenpropathrin, fensulfothion, fenthion, fenvalerate, fluopicolide, phorate, phosalone, phosmet, captan, carbophenothion, lambda-cyhalothrin, malaoxon, malathion, mefenpyr-diethyl, mecarbam, methidathion, metribuzin, mevinphos, oxyfluorfen, parathion-ethyl, parathion-methyl, permethrin, pirimiphos-ethyl, pirimiphos-methyl, procymidone, propetamphos, prothiofos, pyrazophos, triadimefon, triadimenol, triazophos, trifloxystrobin"},{"name":"Range","range":"(0,05 – 0,5) μg/l"},{"name":"Sum of organophosphorus pesticides (calculated)"}],"search_en":"Water, water intended for human consumption Pesticide concentration Gas chromatography with mass spectrometry detection (GC-MS) Environmental Analyses Laboratory Gdynia organophosphorus: azinphos-ethyl, chlorfenvinphos bromophos-ethyl, bifenthrin azinphos-methyl, chlorpyrifos-ethyl, chlorpyrifos-methyl, cyfluthrin, cypermethrin, deltamethrin, demeton-S-methyl, diazinon, diflufenican, dimethoate, ethion, ethoprophos, fenitrothion l, fenpropathrin, fensulfothion, fenthion, fenvalerate, fluopicolide, phorate, phosalone, phosmet, captan, carbophenothion, lambda-cyhalothrin, malaoxon, malathion, mefenpyr-diethyl, mecarbam, methidathion, metribuzin, mevinphos, oxyfluorfen, parathion-ethyl, parathion-methyl, permethrin, pirimiphos-ethyl, pirimiphos-methyl, procymidone, propetamphos, prothiofos, pyrazophos, triadimefon, triadimenol, triazophos, trifloxystrobin Range Sum of organophosphorus pesticides (calculated) PN-EN 12918:2004","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Water, water intended for human consumption","methodology_zh":"农药浓度","parameters_zh":[{"name":"fosforoorganicznych: azinofos etylowy, chlorfenwinfos bromofos etylowy, bifentryna azinofos metylowy, chlorpiryfos etylowy, chloropiryfos metylowy, cyflutryna, cypermetryna, deltametryna, demeton-S-methyl, diazynon, diflufenikan, dimetoat, etion, etoprofos, fenitrotion l, fenpropatryna, fensulfotion, fention, fenwalerat, fluopikolid, forat, fosalon, fosmet, kaptan, karbofenotion, lambda-cyhalotryna, malaokson, malation, mefenpyr dietylowy, mekarbam, metidation, metrybuzyna, mewinfos, oksyfluorofen, paration etylowy, paration metylowy, permetryna, pirymifos etylowy, pirymifos metylowy, procymidon, profetamfos, protiofos, pyrazofos, triadimefon, triadimenol, triazofos, trifloksystrobina"},{"name":"范围","range":"(0,05 – 0,5) μg/l"},{"name":"有机磷农药总量（由计算得出）"}],"search_zh":"水、生活饮用水 农药浓度 气相色谱-质谱法（GC-MS） 环境分析实验室 Gdynia 范围 有机磷农药总量（由计算得出） PN-EN 12918:2004","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"水、生活饮用水","lab_section_zh":"环境分析实验室 Gdynia"},{"_id":"6a7d76396040ebab2620d492","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Ścieki","methodology":"Zawiesiny łatwoopadające","parameters":[{"name":"Zakres","range":"(1,0 – 100) ml/l"}],"technique":"Metoda objętościowa","techniques":["Metoda objętościowa"],"computed":[],"activity":"Zawiesiny łatwoopadające\nZakres (1,0 – 100) ml/l\nMetoda objętościowa","reference":"PN-72/C-04559/03","norm_bases":["PN-72/C-04559/03"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Zawiesiny łatwoopadające\nZakres (1,0 – 100) ml/l\nMetoda objętościowa PN-72/C-04559/03 Scieki Zawiesiny latwoopadajace\nZakres (1,0 – 100) ml/l\nMetoda objetosciowa PN-72/C-04559/03","categories":["water"],"row_index":539,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Settleable solids","parameters_en":[{"name":"Range","range":"(1,0 – 100) ml/l"}],"search_en":"Wastewater Settleable solids Volumetric method Environmental Analyses Laboratory Gdynia Range PN-72/C-04559/03","technique_en":"Volumetric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(1,0 – 100) ml/l"}],"search_zh":"污水 易沉降悬浮物 容量法 环境分析实验室 Gdynia 范围 PN-72/C-04559/03","test_object_zh":"污水","lab_section_zh":"环境分析实验室 Gdynia","technique_zh":"容量法","methodology_zh":"易沉降悬浮物"},{"_id":"6a7d76396040ebab2620d493","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O) kod: 19 08 05","methodology":"pH – w H2O","parameters":[{"name":"Zakres","range":"3,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH – w H2O\nZakres 3,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":"O) Kody odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Osady ściekowe, Odpady O) kod: 19 08 05 pH – w H2O\nZakres 3,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Osady sciekowe, Odpady O) kod: 19 08 05 pH – w H2O\nZakres 3,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water","environment"],"row_index":540,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"pH – in H2O","parameters_en":[{"name":"Range","range":"3,0 – 10,0"}],"regulatory_area_en":"O) Waste codes given according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Sewage sludge, Waste O) code: 19 08 05 pH – in H2O Potentiometric method Environmental Analyses Laboratory Gdynia O) Waste codes given according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Sewage sludge, Waste O) code: 19 08 05","parameters_zh":[{"name":"范围","range":"3,0 – 10,0"}],"search_zh":"pH — 于 H2O 中 电位法 环境分析实验室 Gdynia O) 废物代码依据气候部长关于废物名录的条例给出。 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","lab_section_zh":"环境分析实验室 Gdynia","methodology_zh":"pH — 于 H2O 中","regulatory_area_zh":"O) 废物代码依据气候部长关于废物名录的条例给出。"},{"_id":"6a7d76396040ebab2620d494","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Gleba mineralna","methodology":"Zawartość przyswajalnego fosforu jako P2O5","parameters":[{"name":"Zakres","range":"(1,0 – 50) mg/100 g"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość przyswajalnego fosforu jako P2O5\nZakres (1,0 – 50) mg/100 g\nMetoda spektrofotometryczna","reference":"PN-R-04023:1996","norm_bases":["PN-R-04023:1996"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba mineralna Zawartość przyswajalnego fosforu jako P2O5\nZakres (1,0 – 50) mg/100 g\nMetoda spektrofotometryczna PN-R-04023:1996 Gleba mineralna Zawartosc przyswajalnego fosforu jako P2O5\nZakres (1,0 – 50) mg/100 g\nMetoda spektrofotometryczna PN-R-04023:1996","categories":["environment"],"row_index":541,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Available phosphorus content as P2O5","parameters_en":[{"name":"Range","range":"(1,0 – 50) mg/100 g"}],"search_en":"Mineral soil Available phosphorus content as P2O5 Spectrophotometric method Environmental Analyses Laboratory Gdynia Range PN-R-04023:1996","technique_en":"Spectrophotometric method","test_object_en":"Mineral soil","parameters_zh":[{"name":"范围","range":"(1,0 – 50) mg/100 g"}],"search_zh":"矿质土壤 分光光度法 环境分析实验室 Gdynia 范围 PN-R-04023:1996","technique_zh":"分光光度法","lab_section_zh":"环境分析实验室 Gdynia","test_object_zh":"矿质土壤"},{"_id":"6a7d76396040ebab2620d495","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"pH – w H2O pH – w KCl","parameters":[{"name":"Zakres","range":"3,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH – w H2O pH – w KCl\nZakres 3,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty pH – w H2O pH – w KCl\nZakres 3,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Gleba, grunty pH – w H2O pH – w KCl\nZakres 3,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":542,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"pH – in H2O pH – in KCl","parameters_en":[{"name":"Range","range":"3,0 – 10,0"}],"search_en":"Soil, ground pH – in H2O pH – in KCl Potentiometric method Environmental Analyses Laboratory Gdynia Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Soil, ground","parameters_zh":[{"name":"范围","range":"3,0 – 10,0"}],"search_zh":"土壤、土体 电位法 环境分析实验室 Gdynia 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"土壤、土体","lab_section_zh":"环境分析实验室 Gdynia"},{"_id":"6a7d76396040ebab2620d496","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Skład granulometryczny w zakresie wielkości cząstek (0,0002 – 2,000) mm z podziałem na frakcje","parameters":[{"name":"Zakres","range":"(0,5 – 99,5) %"}],"technique":"Metoda dyfrakcji laserowej","techniques":["Metoda dyfrakcji laserowej"],"computed":[],"activity":"Skład granulometryczny w zakresie wielkości cząstek (0,0002 – 2,000) mm z podziałem na frakcje\nZakres (0,5 – 99,5) %\nMetoda dyfrakcji laserowej","reference":"PN-Z-19012:2020-02","norm_bases":["PN-Z-19012:2020-02"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Skład granulometryczny w zakresie wielkości cząstek (0,0002 – 2,000) mm z podziałem na frakcje\nZakres (0,5 – 99,5) %\nMetoda dyfrakcji laserowej PN-Z-19012:2020-02 Gleba, grunty Sklad granulometryczny w zakresie wielkosci czastek (0,0002 – 2,000) mm z podzialem na frakcje\nZakres (0,5 – 99,5) %\nMetoda dyfrakcji laserowej PN-Z-19012:2020-02","categories":["environment"],"row_index":543,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Particle size distribution in the particle size range (0,0002 – 2,000) mm divided into fractions","parameters_en":[{"name":"Range","range":"(0,5 – 99,5) %"}],"search_en":"Soil, ground Particle size distribution in the particle size range (0,0002 – 2,000) mm divided into fractions Laser diffraction method Environmental Analyses Laboratory Gdynia Range PN-Z-19012:2020-02","technique_en":"Laser diffraction method","test_object_en":"Soil, ground","parameters_zh":[{"name":"范围","range":"(0,5 – 99,5) %"}],"search_zh":"土壤、土体 激光衍射法 环境分析实验室 Gdynia 范围 PN-Z-19012:2020-02","test_object_zh":"土壤、土体","lab_section_zh":"环境分析实验室 Gdynia","technique_zh":"激光衍射法"},{"_id":"6a7d76396040ebab2620d497","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Współczynnik filtracji – wodoprzepuszczalność","parameters":[{"name":"Zakres","range":"(0,01 ≤ d20 < 2 mm)"},{"name":"(z obliczeń na podstawie krzywej uziarnienia – wzór USBSC)"}],"technique":null,"techniques":[],"computed":[],"activity":"Współczynnik filtracji – wodoprzepuszczalność\nZakres:\nZakres (0,01 ≤ d20 < 2 mm)\n(z obliczeń na podstawie krzywej uziarnienia – wzór USBSC)","reference":"PB-483 wyd. II z dn. 23.05.2022","norm_bases":["PB-483 wyd. II z dn. 23.05.2022"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Współczynnik filtracji – wodoprzepuszczalność\nZakres:\nZakres (0,01 ≤ d20 < 2 mm)\n(z obliczeń na podstawie krzywej uziarnienia – wzór USBSC) PB-483 wyd. II z dn. 23.05.2022 Gleba, grunty Wspolczynnik filtracji – wodoprzepuszczalnosc\nZakres:\nZakres (0,01 ≤ d20 < 2 mm)\n(z obliczen na podstawie krzywej uziarnienia – wzor USBSC) PB-483 wyd. II z dn. 23.05.2022","categories":["environment"],"row_index":544,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Coefficient of permeability – water permeability","parameters_en":[{"name":"Range","range":"(0,01 ≤ d20 < 2 mm)"},{"name":"(calculated from the particle size distribution curve – USBSC formula)"}],"search_en":"Soil, ground Coefficient of permeability – water permeability Environmental Analyses Laboratory Gdynia Range (calculated from the particle size distribution curve – USBSC formula) PB-483 wyd. II z dn. 23.05.2022","test_object_en":"Soil, ground","parameters_zh":[{"name":"范围","range":"(0,01 ≤ d20 < 2 mm)"},{"name":"（依据颗粒级配曲线计算得出 － USBSC 公式）"}],"search_zh":"土壤、土体 环境分析实验室 Gdynia 范围 （依据颗粒级配曲线计算得出 － USBSC 公式） PB-483 wyd. II z dn. 23.05.2022","test_object_zh":"土壤、土体","lab_section_zh":"环境分析实验室 Gdynia"},{"_id":"6a7d76396040ebab2620d498","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Gleba, grunty, Osady ściekowe, Odpady O) kod: 19 08 05","methodology":"Sucha masa / zawartość wody","parameters":[{"name":"Zakres","range":"(1,0 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa / zawartość wody\nZakres (1,0 – 99,0) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02 metoda A","norm_bases":["PN-EN 15934:2013-02 metoda A"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":"O) Kody odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Gleba, grunty, Osady ściekowe, Odpady O) kod: 19 08 05 Sucha masa / zawartość wody\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15934:2013-02 metoda A Gleba, grunty, Osady sciekowe, Odpady O) kod: 19 08 05 Sucha masa / zawartosc wody\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15934:2013-02 metoda A","categories":["water","environment"],"row_index":545,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Dry matter / water content","parameters_en":[{"name":"Range","range":"(1,0 – 99,0) %"}],"regulatory_area_en":"O) Waste codes given according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Soil, ground, Sewage sludge, Waste O) code: 19 08 05 Dry matter / water content Gravimetric method Environmental Analyses Laboratory Gdynia O) Waste codes given according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN 15934:2013-02 metoda A","technique_en":"Gravimetric method","test_object_en":"Soil, ground, Sewage sludge, Waste O) code: 19 08 05","parameters_zh":[{"name":"范围","range":"(1,0 – 99,0) %"}],"search_zh":"干物质 / 水分含量 重量法 环境分析实验室 Gdynia O) 废物代码依据气候部长关于废物名录的条例给出。 范围 PN-EN 15934:2013-02 metoda A","technique_zh":"重量法","lab_section_zh":"环境分析实验室 Gdynia","methodology_zh":"干物质 / 水分含量","regulatory_area_zh":"O) 废物代码依据气候部长关于废物名录的条例给出。"},{"_id":"6a7d76396040ebab2620d499","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Gleba, Osady ściekowe, Odpady O) kod: 19 08 05","methodology":"Zawartość azotu amonowego","parameters":[{"name":"Zakres","range":"(0,05 – 2,00) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu amonowego\nZakres (0,05 – 2,00) %\nMetoda miareczkowa","reference":"PB-178 wyd. I z dn. 14.08.2012","norm_bases":["PB-178 wyd. I z dn. 14.08.2012"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":"O) Kody odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Gleba, Osady ściekowe, Odpady O) kod: 19 08 05 Zawartość azotu amonowego\nZakres (0,05 – 2,00) %\nMetoda miareczkowa PB-178 wyd. I z dn. 14.08.2012 Gleba, Osady sciekowe, Odpady O) kod: 19 08 05 Zawartosc azotu amonowego\nZakres (0,05 – 2,00) %\nMetoda miareczkowa PB-178 wyd. I z dn. 14.08.2012","categories":["environment","water"],"row_index":546,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Ammonium nitrogen content","parameters_en":[{"name":"Range","range":"(0,05 – 2,00) %"}],"regulatory_area_en":"O) Waste codes given according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Soil, Sewage sludge, Waste O) code: 19 08 05 Ammonium nitrogen content Titrimetric method Environmental Analyses Laboratory Gdynia O) Waste codes given according to the Regulation of the Minister of Climate on the waste catalogue. Range PB-178 wyd. I z dn. 14.08.2012","technique_en":"Titrimetric method","test_object_en":"Soil, Sewage sludge, Waste O) code: 19 08 05","parameters_zh":[{"name":"范围","range":"(0,05 – 2,00) %"}],"search_zh":"氨氮含量 滴定法 环境分析实验室 Gdynia O) 废物代码依据气候部长关于废物名录的条例给出。 范围 PB-178 wyd. I z dn. 14.08.2012","technique_zh":"滴定法","lab_section_zh":"环境分析实验室 Gdynia","methodology_zh":"氨氮含量","regulatory_area_zh":"O) 废物代码依据气候部长关于废物名录的条例给出。"},{"_id":"6a7d76396040ebab2620d49a","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Gleba, Osady ściekowe, Odpady O) kod: 19 08 05","methodology":"Zawartość azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,05 – 8,00) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu Kjeldahla\nZakres (0,05 – 8,00) %\nMetoda miareczkowa","reference":"PN-EN 13342:2002","norm_bases":["PN-EN 13342:2002"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":"O) Kody odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Gleba, Osady ściekowe, Odpady O) kod: 19 08 05 Zawartość azotu Kjeldahla\nZakres (0,05 – 8,00) %\nMetoda miareczkowa PN-EN 13342:2002 Gleba, Osady sciekowe, Odpady O) kod: 19 08 05 Zawartosc azotu Kjeldahla\nZakres (0,05 – 8,00) %\nMetoda miareczkowa PN-EN 13342:2002","categories":["environment","water"],"row_index":547,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Kjeldahl nitrogen content","parameters_en":[{"name":"Range","range":"(0,05 – 8,00) %"}],"regulatory_area_en":"O) Waste codes given according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Soil, Sewage sludge, Waste O) code: 19 08 05 Kjeldahl nitrogen content Titrimetric method Environmental Analyses Laboratory Gdynia O) Waste codes given according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN 13342:2002","technique_en":"Titrimetric method","test_object_en":"Soil, Sewage sludge, Waste O) code: 19 08 05","parameters_zh":[{"name":"范围","range":"(0,05 – 8,00) %"}],"search_zh":"凯氏氮含量 滴定法 环境分析实验室 Gdynia O) 废物代码依据气候部长关于废物名录的条例给出。 范围 PN-EN 13342:2002","technique_zh":"滴定法","lab_section_zh":"环境分析实验室 Gdynia","methodology_zh":"凯氏氮含量","regulatory_area_zh":"O) 废物代码依据气候部长关于废物名录的条例给出。"},{"_id":"6a7d76396040ebab2620d49b","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Gleba, grunty, Osady ściekowe, Odpady O) kod: 19 08 05","methodology":"Straty przy prażeniu suchej masy (LOI) / pozostałość po prażeniu","parameters":[{"name":"Zakres","range":"(0,5 – 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy (LOI) / pozostałość po prażeniu\nZakres (0,5 – 99,5) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":"O) Kody odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Gleba, grunty, Osady ściekowe, Odpady O) kod: 19 08 05 Straty przy prażeniu suchej masy (LOI) / pozostałość po prażeniu\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 15935:2022-01 Gleba, grunty, Osady sciekowe, Odpady O) kod: 19 08 05 Straty przy prazeniu suchej masy (LOI) / pozostalosc po prazeniu\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["environment","water"],"row_index":548,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Loss on ignition of dry matter (LOI) / residue on ignition","parameters_en":[{"name":"Range","range":"(0,5 – 99,5) %"}],"regulatory_area_en":"O) Waste codes given according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Soil, ground, Sewage sludge, Waste O) code: 19 08 05 Loss on ignition of dry matter (LOI) / residue on ignition Gravimetric method Environmental Analyses Laboratory Gdynia O) Waste codes given according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN 15935:2022-01","technique_en":"Gravimetric method","test_object_en":"Soil, ground, Sewage sludge, Waste O) code: 19 08 05","parameters_zh":[{"name":"范围","range":"(0,5 – 99,5) %"}],"search_zh":"干物质烧失量（LOI）/ 灼烧残渣 重量法 环境分析实验室 Gdynia O) 废物代码依据气候部长关于废物名录的条例给出。 范围 PN-EN 15935:2022-01","technique_zh":"重量法","lab_section_zh":"环境分析实验室 Gdynia","regulatory_area_zh":"O) 废物代码依据气候部长关于废物名录的条例给出。","methodology_zh":"干物质烧失量（LOI）/ 灼烧残渣"},{"_id":"6a7d76396040ebab2620d49c","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Gleba","methodology":"Indeks oleju mineralnego, w tym suma węglowodorów C12-C35","parameters":[{"name":"Zakres","range":"(30 – 3000) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Indeks oleju mineralnego, w tym suma węglowodorów C12-C35\nZakres (30 – 3000) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PN-EN ISO 16703:2011","norm_bases":["PN-EN ISO 16703:2011"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Indeks oleju mineralnego, w tym suma węglowodorów C12-C35\nZakres (30 – 3000) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PN-EN ISO 16703:2011 Gleba Indeks oleju mineralnego, w tym suma weglowodorow C12-C35\nZakres (30 – 3000) mg/kg\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PN-EN ISO 16703:2011","categories":["environment","petro"],"row_index":549,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Mineral oil index, including the sum of hydrocarbons C12-C35","parameters_en":[{"name":"Range","range":"(30 – 3000) mg/kg"}],"search_en":"Soil Mineral oil index, including the sum of hydrocarbons C12-C35 Gas chromatography with mass spectrometry detection (GC-MS) Environmental Analyses Laboratory Gdynia Range PN-EN ISO 16703:2011","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(30 – 3000) mg/kg"}],"search_zh":"土壤 气相色谱-质谱法（GC-MS） 环境分析实验室 Gdynia 范围 PN-EN ISO 16703:2011","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"土壤","lab_section_zh":"环境分析实验室 Gdynia"},{"_id":"6a7d76396040ebab2620d49d","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby)","methodology":"Sucha masa / zawartość wody","parameters":[{"name":"Zakres","range":"(1,0 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa / zawartość wody\nZakres (1,0 – 99,0) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02 metoda A","norm_bases":["PN-EN 15934:2013-02 metoda A"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) Sucha masa / zawartość wody\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15934:2013-02 metoda A Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby (polepszacze gleby) Sucha masa / zawartosc wody\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15934:2013-02 metoda A","categories":["water"],"row_index":550,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Dry matter / water content","parameters_en":[{"name":"Range","range":"(1,0 – 99,0) %"}],"search_en":"Plant cultivation aids: - soil improvers Dry matter / water content Gravimetric method Environmental Analyses Laboratory Gdynia Range PN-EN 15934:2013-02 metoda A","technique_en":"Gravimetric method","test_object_en":"Plant cultivation aids: - soil improvers","parameters_zh":[{"name":"范围","range":"(1,0 – 99,0) %"}],"search_zh":"植物栽培辅助制剂：－ 土壤改良剂 干物质 / 水分含量 重量法 环境分析实验室 Gdynia 范围 PN-EN 15934:2013-02 metoda A","technique_zh":"重量法","lab_section_zh":"环境分析实验室 Gdynia","methodology_zh":"干物质 / 水分含量","test_object_zh":"植物栽培辅助制剂：－ 土壤改良剂"},{"_id":"6a7d76396040ebab2620d49e","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby)","methodology":"Straty przy prażeniu suchej masy (LOI) / pozostałość po prażeniu","parameters":[{"name":"Zakres","range":"(1,0 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy (LOI) / pozostałość po prażeniu\nZakres (1,0 – 99,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) Straty przy prażeniu suchej masy (LOI) / pozostałość po prażeniu\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15935:2022-01 Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby (polepszacze gleby) Straty przy prazeniu suchej masy (LOI) / pozostalosc po prazeniu\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["other"],"row_index":551,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Loss on ignition of dry matter (LOI) / residue on ignition","parameters_en":[{"name":"Range","range":"(1,0 – 99,0) %"}],"search_en":"Plant cultivation aids: - soil improvers Loss on ignition of dry matter (LOI) / residue on ignition Gravimetric method Environmental Analyses Laboratory Gdynia Range PN-EN 15935:2022-01","technique_en":"Gravimetric method","test_object_en":"Plant cultivation aids: - soil improvers","parameters_zh":[{"name":"范围","range":"(1,0 – 99,0) %"}],"search_zh":"植物栽培辅助制剂：－ 土壤改良剂 干物质烧失量（LOI）/ 灼烧残渣 重量法 环境分析实验室 Gdynia 范围 PN-EN 15935:2022-01","technique_zh":"重量法","lab_section_zh":"环境分析实验室 Gdynia","methodology_zh":"干物质烧失量（LOI）/ 灼烧残渣","test_object_zh":"植物栽培辅助制剂：－ 土壤改良剂"},{"_id":"6a7d76396040ebab2620d49f","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby)","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10\nMetoda potencjometryczna","reference":"PN-EN 12176:2004","norm_bases":["PN-EN 12176:2004"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) pH\nZakres 4,0 – 10\nMetoda potencjometryczna PN-EN 12176:2004 Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby (polepszacze gleby) pH\nZakres 4,0 – 10\nMetoda potencjometryczna PN-EN 12176:2004","categories":["other"],"row_index":552,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10"}],"search_en":"Plant cultivation aids: - soil improvers pH Potentiometric method Environmental Analyses Laboratory Gdynia Range PN-EN 12176:2004","technique_en":"Potentiometric method","test_object_en":"Plant cultivation aids: - soil improvers","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10"}],"search_zh":"植物栽培辅助制剂：－ 土壤改良剂 pH 值 电位法 环境分析实验室 Gdynia 范围 PN-EN 12176:2004","technique_zh":"电位法","lab_section_zh":"环境分析实验室 Gdynia","test_object_zh":"植物栽培辅助制剂：－ 土壤改良剂"},{"_id":"6a7d76396040ebab2620d4a0","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby)","methodology":"Zawartość azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,5 – 8,00) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu Kjeldahla\nZakres (0,5 – 8,00) %\nMetoda miareczkowa","reference":"PN-EN 13342:2002","norm_bases":["PN-EN 13342:2002"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) Zawartość azotu Kjeldahla\nZakres (0,5 – 8,00) %\nMetoda miareczkowa PN-EN 13342:2002 Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby (polepszacze gleby) Zawartosc azotu Kjeldahla\nZakres (0,5 – 8,00) %\nMetoda miareczkowa PN-EN 13342:2002","categories":["other"],"row_index":553,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Kjeldahl nitrogen content","parameters_en":[{"name":"Range","range":"(0,5 – 8,00) %"}],"search_en":"Plant cultivation aids: - soil improvers Kjeldahl nitrogen content Titrimetric method Environmental Analyses Laboratory Gdynia Range PN-EN 13342:2002","technique_en":"Titrimetric method","test_object_en":"Plant cultivation aids: - soil improvers","parameters_zh":[{"name":"范围","range":"(0,5 – 8,00) %"}],"search_zh":"植物栽培辅助制剂：－ 土壤改良剂 凯氏氮含量 滴定法 环境分析实验室 Gdynia 范围 PN-EN 13342:2002","technique_zh":"滴定法","lab_section_zh":"环境分析实验室 Gdynia","methodology_zh":"凯氏氮含量","test_object_zh":"植物栽培辅助制剂：－ 土壤改良剂"},{"_id":"6a7d76396040ebab2620d4a1","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki E","methodology":"Stężenie lotnych związków organicznych","parameters":[],"technique":"Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T-GC-MS)","techniques":["Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T-GC-MS)"],"computed":[],"activity":"Stężenie lotnych związków organicznych\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T-GC-MS)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki E Stężenie lotnych związków organicznych\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T-GC-MS) Normy Procedury badawcze Woda, woda do spozycia przez ludzi, scieki E Stezenie lotnych zwiazkow organicznych\nMetoda chromatografii gazowej z technika wylapywania i wyplukiwania (Purge&Trap) i detekcja spektrometria mas (P&T-GC-MS) Normy Procedury badawcze","categories":["water"],"row_index":554,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Concentration of volatile organic compounds","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Water, water intended for human consumption, wastewater E Concentration of volatile organic compounds Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (P&T-GC-MS) Environmental Analyses Laboratory Gdynia E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (P&T-GC-MS)","test_object_en":"Water, water intended for human consumption, wastewater E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"水、生活饮用水、废水 E 挥发性有机物浓度 环境分析实验室 Gdynia E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","lab_section_zh":"环境分析实验室 Gdynia","methodology_zh":"挥发性有机物浓度","test_object_zh":"水、生活饮用水、废水 E"},{"_id":"6a7d76396040ebab2620d4a2","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki E","methodology":"Stężenie anionów","parameters":[{"name":"Suma (z obliczeń)"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nSuma (z obliczeń)\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki E Stężenie anionów\nSuma (z obliczeń)\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Normy Woda, woda do spozycia przez ludzi, scieki E Stezenie anionow\nSuma (z obliczen)\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Normy","categories":["water"],"row_index":555,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Anion concentrations","parameters_en":[{"name":"Sum (calculated)"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Water, water intended for human consumption, wastewater E Anion concentrations Ion chromatography with conductometric detection (IC-CD) Environmental Analyses Laboratory Gdynia E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Sum (calculated) Normy","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, water intended for human consumption, wastewater E","methodology_zh":"阴离子浓度","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"水、生活饮用水、废水 E 阴离子浓度 离子色谱-电导检测法（IC-CD） 环境分析实验室 Gdynia E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 总量（由计算得出） Normy","technique_zh":"离子色谱-电导检测法（IC-CD）","lab_section_zh":"环境分析实验室 Gdynia","parameters_zh":[{"name":"总量（由计算得出）"}],"test_object_zh":"水、生活饮用水、废水 E"},{"_id":"6a7d76396040ebab2620d4a3","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi E","methodology":"Stężenie kationów","parameters":[{"name":"Suma (z obliczeń)"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie kationów\nSuma (z obliczeń)\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Analiz Środowiska Gdynia","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Woda, woda do spożycia przez ludzi E Stężenie kationów\nSuma (z obliczeń)\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Normy Woda, woda do spozycia przez ludzi E Stezenie kationow\nSuma (z obliczen)\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Normy","categories":["water"],"row_index":556,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Gdynia","methodology_en":"Cation concentrations","parameters_en":[{"name":"Sum (calculated)"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Water, water intended for human consumption E Cation concentrations Ion chromatography with conductometric detection (IC-CD) Environmental Analyses Laboratory Gdynia E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Sum (calculated) Normy","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, water intended for human consumption E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"水、生活饮用水 E 阳离子浓度 离子色谱-电导检测法（IC-CD） 环境分析实验室 Gdynia E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 总量（由计算得出） Normy","technique_zh":"离子色谱-电导检测法（IC-CD）","lab_section_zh":"环境分析实验室 Gdynia","methodology_zh":"阳离子浓度","parameters_zh":[{"name":"总量（由计算得出）"}],"test_object_zh":"水、生活饮用水 E"},{"_id":"6a7d76396040ebab2620d4a4","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"3,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 3,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Analiz Środowiska Zgierz","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki pH\nZakres 3,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Woda do spozycia przez ludzi, Scieki pH\nZakres 3,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":557,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Zgierz","methodology_en":"pH","parameters_en":[{"name":"Range","range":"3,0 – 10,0"}],"search_en":"Water, Water intended for human consumption, Wastewater pH Potentiometric method Environmental Analyses Laboratory Zgierz Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"3,0 – 10,0"}],"search_zh":"水、生活饮用水、废水 pH 值 电位法 环境分析实验室 Zgierz 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水、废水","lab_section_zh":"环境分析实验室 Zgierz"},{"_id":"6a7d76396040ebab2620d4a5","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10 – 3000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (10 – 3000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Pracownia Analiz Środowiska Zgierz","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Przewodność elektryczna właściwa\nZakres (10 – 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Woda do spozycia przez ludzi, Scieki Przewodnosc elektryczna wlasciwa\nZakres (10 – 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":558,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Zgierz","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(10 – 3000) μS/cm"}],"search_en":"Water, Water intended for human consumption, Wastewater Electrical conductivity Conductometric method Environmental Analyses Laboratory Zgierz Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10 – 3000) μS/cm"}],"search_zh":"水、生活饮用水、废水 电导率 电导法 环境分析实验室 Zgierz 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水、废水","lab_section_zh":"环境分析实验室 Zgierz"},{"_id":"6a7d76396040ebab2620d4a6","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,3 – 60) mg/l"},{"name":"Stężenie azotu azotanowego"},{"name":"Zakres","range":"(0,068 – 13,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres:\nZakres (0,3 – 60) mg/l\nStężenie azotu azotanowego\nZakres (0,068 – 13,5) mg/l\nMetoda spektrofotometryczna","reference":"PB-433 wyd. I z dn. 01.06.2021 | na podstawie metody HACH 8039","norm_bases":["PB-433 wyd. I z dn. 01.06.2021","na podstawie metody HACH 8039"],"lab_section":"Pracownia Analiz Środowiska Zgierz","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie azotanów\nZakres:\nZakres (0,3 – 60) mg/l\nStężenie azotu azotanowego\nZakres (0,068 – 13,5) mg/l\nMetoda spektrofotometryczna PB-433 wyd. I z dn. 01.06.2021 | na podstawie metody HACH 8039 Woda, Woda do spozycia przez ludzi, Scieki Stezenie azotanow\nZakres:\nZakres (0,3 – 60) mg/l\nStezenie azotu azotanowego\nZakres (0,068 – 13,5) mg/l\nMetoda spektrofotometryczna PB-433 wyd. I z dn. 01.06.2021 | na podstawie metody HACH 8039","categories":["water"],"row_index":559,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Zgierz","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(0,3 – 60) mg/l"},{"name":"Nitrate nitrogen concentration"},{"name":"Range","range":"(0,068 – 13,5) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Nitrate concentration Spectrophotometric method Environmental Analyses Laboratory Zgierz Range Nitrate nitrogen concentration Range PB-433 wyd. I z dn. 01.06.2021 | na podstawie metody HACH 8039","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,3 – 60) mg/l"},{"name":"硝态氮浓度"},{"name":"范围","range":"(0,068 – 13,5) mg/l"}],"search_zh":"水、生活饮用水、废水 硝酸盐浓度 分光光度法 环境分析实验室 Zgierz 范围 硝态氮浓度 范围 PB-433 wyd. I z dn. 01.06.2021 | na podstawie metody HACH 8039","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水","lab_section_zh":"环境分析实验室 Zgierz"},{"_id":"6a7d76396040ebab2620d4a7","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,050 – 1,00) mg/l"},{"name":"Stężenie azotu azotynowego"},{"name":"Zakres","range":"(0,02 – 0,300) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres:\nZakres (0,050 – 1,00) mg/l\nStężenie azotu azotynowego\nZakres (0,02 – 0,300) mg/l\nMetoda spektrofotometryczna","reference":"PB-461 wyd. I z dn. 01.06.2021 | na podstawie metody HACH 8507","norm_bases":["PB-461 wyd. I z dn. 01.06.2021","na podstawie metody HACH 8507"],"lab_section":"Pracownia Analiz Środowiska Zgierz","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie azotynów\nZakres:\nZakres (0,050 – 1,00) mg/l\nStężenie azotu azotynowego\nZakres (0,02 – 0,300) mg/l\nMetoda spektrofotometryczna PB-461 wyd. I z dn. 01.06.2021 | na podstawie metody HACH 8507 Woda, Woda do spozycia przez ludzi, Scieki Stezenie azotynow\nZakres:\nZakres (0,050 – 1,00) mg/l\nStezenie azotu azotynowego\nZakres (0,02 – 0,300) mg/l\nMetoda spektrofotometryczna PB-461 wyd. I z dn. 01.06.2021 | na podstawie metody HACH 8507","categories":["water"],"row_index":560,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Zgierz","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,050 – 1,00) mg/l"},{"name":"Nitrite nitrogen concentration"},{"name":"Range","range":"(0,02 – 0,300) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Nitrite concentration Spectrophotometric method Environmental Analyses Laboratory Zgierz Range Nitrite nitrogen concentration Range PB-461 wyd. I z dn. 01.06.2021 | na podstawie metody HACH 8507","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 1,00) mg/l"},{"name":"亚硝态氮浓度"},{"name":"范围","range":"(0,02 – 0,300) mg/l"}],"search_zh":"水、生活饮用水、废水 亚硝酸盐浓度 分光光度法 环境分析实验室 Zgierz 范围 亚硝态氮浓度 范围 PB-461 wyd. I z dn. 01.06.2021 | na podstawie metody HACH 8507","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水","lab_section_zh":"环境分析实验室 Zgierz"},{"_id":"6a7d76396040ebab2620d4a8","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie siarczanów (VI)","parameters":[{"name":"Zakres","range":"(2 – 300) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczanów (VI)\nZakres (2 – 300) mg/l\nMetoda spektrofotometryczna","reference":"PB-432 wyd. I z dn. 01.06.2021 | na podstawie metody HACH 8051","norm_bases":["PB-432 wyd. I z dn. 01.06.2021","na podstawie metody HACH 8051"],"lab_section":"Pracownia Analiz Środowiska Zgierz","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie siarczanów (VI)\nZakres (2 – 300) mg/l\nMetoda spektrofotometryczna PB-432 wyd. I z dn. 01.06.2021 | na podstawie metody HACH 8051 Woda, Woda do spozycia przez ludzi, Scieki Stezenie siarczanow (VI)\nZakres (2 – 300) mg/l\nMetoda spektrofotometryczna PB-432 wyd. I z dn. 01.06.2021 | na podstawie metody HACH 8051","categories":["water"],"row_index":561,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Zgierz","methodology_en":"Sulphate (VI) concentration","parameters_en":[{"name":"Range","range":"(2 – 300) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Sulphate (VI) concentration Spectrophotometric method Environmental Analyses Laboratory Zgierz Range PB-432 wyd. I z dn. 01.06.2021 | na podstawie metody HACH 8051","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(2 – 300) mg/l"}],"search_zh":"水、生活饮用水、废水 硫酸盐(VI)浓度 分光光度法 环境分析实验室 Zgierz 范围 PB-432 wyd. I z dn. 01.06.2021 | na podstawie metody HACH 8051","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水","lab_section_zh":"环境分析实验室 Zgierz","methodology_zh":"硫酸盐(VI)浓度"},{"_id":"6a7d76396040ebab2620d4a9","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie fluorków","parameters":[{"name":"Zakres","range":"(0,10 – 10) mg/l"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Stężenie fluorków\nZakres (0,10 – 10) mg/l\nMetoda potencjometryczna","reference":"PN-78/C-04588/03","norm_bases":["PN-78/C-04588/03"],"lab_section":"Pracownia Analiz Środowiska Zgierz","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie fluorków\nZakres (0,10 – 10) mg/l\nMetoda potencjometryczna PN-78/C-04588/03 Woda, Woda do spozycia przez ludzi, Scieki Stezenie fluorkow\nZakres (0,10 – 10) mg/l\nMetoda potencjometryczna PN-78/C-04588/03","categories":["water"],"row_index":562,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Zgierz","methodology_en":"Fluoride concentration","parameters_en":[{"name":"Range","range":"(0,10 – 10) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Fluoride concentration Potentiometric method Environmental Analyses Laboratory Zgierz Range PN-78/C-04588/03","technique_en":"Potentiometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(0,10 – 10) mg/l"}],"search_zh":"水、生活饮用水、废水 氟化物浓度 电位法 环境分析实验室 Zgierz 范围 PN-78/C-04588/03","technique_zh":"电位法","test_object_zh":"水、生活饮用水、废水","methodology_zh":"氟化物浓度","lab_section_zh":"环境分析实验室 Zgierz"},{"_id":"6a7d76396040ebab2620d4aa","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-463 wyd. II z dn. 23.07.2021","norm_bases":["PB-463 wyd. II z dn. 23.07.2021"],"lab_section":"Pracownia Analiz Środowiska Zgierz","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie azotu ogólnego (z obliczeń) PB-463 wyd. II z dn. 23.07.2021 Woda, Woda do spozycia przez ludzi, Scieki Stezenie azotu ogolnego (z obliczen) PB-463 wyd. II z dn. 23.07.2021","categories":["water"],"row_index":563,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Zgierz","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water, Water intended for human consumption, Wastewater Total nitrogen concentration (calculated) Environmental Analyses Laboratory Zgierz PB-463 wyd. II z dn. 23.07.2021","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"水、生活饮用水、废水 总氮浓度（计算值） 环境分析实验室 Zgierz PB-463 wyd. II z dn. 23.07.2021","test_object_zh":"水、生活饮用水、废水","lab_section_zh":"环境分析实验室 Zgierz"},{"_id":"6a7d76396040ebab2620d4ab","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Zasadowość ogólna","parameters":[{"name":"Zakres","range":"(0,40 – 20) mmol/l"},{"name":"Stężenie wodorowęglanów (z obliczeń)"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zasadowość ogólna\nZakres:\nZakres (0,40 – 20) mmol/l\nStężenie wodorowęglanów (z obliczeń)\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":"Pracownia Analiz Środowiska Zgierz","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Zasadowość ogólna\nZakres:\nZakres (0,40 – 20) mmol/l\nStężenie wodorowęglanów (z obliczeń)\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004 Woda, Woda do spozycia przez ludzi, Scieki Zasadowosc ogolna\nZakres:\nZakres (0,40 – 20) mmol/l\nStezenie wodoroweglanow (z obliczen)\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004","categories":["water"],"row_index":564,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Zgierz","methodology_en":"Total alkalinity","parameters_en":[{"name":"Range","range":"(0,40 – 20) mmol/l"},{"name":"Bicarbonate concentration (calculated)"}],"search_en":"Water, Water intended for human consumption, Wastewater Total alkalinity Titrimetric method Environmental Analyses Laboratory Zgierz Range Bicarbonate concentration (calculated) PN-EN ISO 9963-1:2001+Ap1:2004","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(0,40 – 20) mmol/l"},{"name":"碳酸氢盐浓度（由计算得出）"}],"search_zh":"水、生活饮用水、废水 总碱度 滴定法 环境分析实验室 Zgierz 范围 碳酸氢盐浓度（由计算得出） PN-EN ISO 9963-1:2001+Ap1:2004","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、废水","methodology_zh":"总碱度","lab_section_zh":"环境分析实验室 Zgierz"},{"_id":"6a7d76396040ebab2620d4ac","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,00 – 10000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,00 – 10000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Pracownia Analiz Środowiska Zgierz","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie chlorków\nZakres (5,00 – 10000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, Woda do spozycia przez ludzi, Scieki Stezenie chlorkow\nZakres (5,00 – 10000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":565,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Zgierz","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,00 – 10000) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Chloride concentration Titrimetric method Environmental Analyses Laboratory Zgierz Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,00 – 10000) mg/l"}],"search_zh":"水、生活饮用水、废水 氯化物浓度 滴定法 环境分析实验室 Zgierz 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、废水","lab_section_zh":"环境分析实验室 Zgierz"},{"_id":"6a7d76396040ebab2620d4ad","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie lotnych związków organicznych","parameters":[{"name":"Chloroform","range":"(1,0 – 200) μg/l"},{"name":"Bromodichlorometan","range":"(1,0 – 200) μg/l"},{"name":"Dibromochlorometan","range":"(1,0 – 200) μg/l"},{"name":"Bromoform","range":"(1,0 – 200) μg/l"},{"name":"Tetrachlorometan (czterochlorek węgla)","range":"(0,5 – 25) μg/l"},{"name":"Zakres","range":"1,2-dichloroetan (1,0 – 200) μg/l"},{"name":"Trichloroeten","range":"(1,0 – 200) μg/l"},{"name":"Tetrachloreten","range":"(1,0 – 200) μg/l"},{"name":"Heksachlorobutadien","range":"(0,10 – 12,5) μg/l"},{"name":"Chlorek winylu","range":"(0,10 – 12,5) μg/l"},{"name":"Benzen","range":"(0,5 – 100) μg/l"},{"name":"Toluen","range":"(0,5 – 100) μg/l"},{"name":"Etylobenzen","range":"(1,0 – 200) μg/l"},{"name":"(m+p)-ksylen","range":"(0,5 – 200) μg/l"},{"name":"o-ksylen","range":"(0,5 – 200) μg/l"},{"name":"Suma lotnych związków organicznych (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge & Trap) i detekcją spektrometrią mas (P&T-GC-MS)","techniques":["Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge & Trap) i detekcją spektrometrią mas (P&T-GC-MS)"],"computed":[],"activity":"Stężenie lotnych związków organicznych\nZakres:\nChloroform (1,0 – 200) μg/l\nBromodichlorometan (1,0 – 200) μg/l\nDibromochlorometan (1,0 – 200) μg/l\nBromoform (1,0 – 200) μg/l\nTetrachlorometan (czterochlorek węgla) (0,5 – 25) μg/l\nZakres 1,2-dichloroetan (1,0 – 200) μg/l\nTrichloroeten (1,0 – 200) μg/l\nTetrachloreten (1,0 – 200) μg/l\nHeksachlorobutadien (0,10 – 12,5) μg/l\nChlorek winylu (0,10 – 12,5) μg/l\nBenzen (0,5 – 100) μg/l\nToluen (0,5 – 100) μg/l\nEtylobenzen (1,0 – 200) μg/l\n(m+p)-ksylen (0,5 – 200) μg/l\no-ksylen (0,5 – 200) μg/l\nSuma lotnych związków organicznych (z obliczeń)\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge & Trap) i detekcją spektrometrią mas (P&T-GC-MS)","reference":"PN-EN ISO 15680:2008","norm_bases":["PN-EN ISO 15680:2008"],"lab_section":"Pracownia Analiz Środowiska Zgierz","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie lotnych związków organicznych\nZakres:\nChloroform (1,0 – 200) μg/l\nBromodichlorometan (1,0 – 200) μg/l\nDibromochlorometan (1,0 – 200) μg/l\nBromoform (1,0 – 200) μg/l\nTetrachlorometan (czterochlorek węgla) (0,5 – 25) μg/l\nZakres 1,2-dichloroetan (1,0 – 200) μg/l\nTrichloroeten (1,0 – 200) μg/l\nTetrachloreten (1,0 – 200) μg/l\nHeksachlorobutadien (0,10 – 12,5) μg/l\nChlorek winylu (0,10 – 12,5) μg/l\nBenzen (0,5 – 100) μg/l\nToluen (0,5 – 100) μg/l\nEtylobenzen (1,0 – 200) μg/l\n(m+p)-ksylen (0,5 – 200) μg/l\no-ksylen (0,5 – 200) μg/l\nSuma lotnych związków organicznych (z obliczeń)\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge & Trap) i detekcją spektrometrią mas (P&T-GC-MS) PN-EN ISO 15680:2008 Woda, Woda do spozycia przez ludzi, Scieki Stezenie lotnych zwiazkow organicznych\nZakres:\nChloroform (1,0 – 200) μg/l\nBromodichlorometan (1,0 – 200) μg/l\nDibromochlorometan (1,0 – 200) μg/l\nBromoform (1,0 – 200) μg/l\nTetrachlorometan (czterochlorek wegla) (0,5 – 25) μg/l\nZakres 1,2-dichloroetan (1,0 – 200) μg/l\nTrichloroeten (1,0 – 200) μg/l\nTetrachloreten (1,0 – 200) μg/l\nHeksachlorobutadien (0,10 – 12,5) μg/l\nChlorek winylu (0,10 – 12,5) μg/l\nBenzen (0,5 – 100) μg/l\nToluen (0,5 – 100) μg/l\nEtylobenzen (1,0 – 200) μg/l\n(m+p)-ksylen (0,5 – 200) μg/l\no-ksylen (0,5 – 200) μg/l\nSuma lotnych zwiazkow organicznych (z obliczen)\nMetoda chromatografii gazowej z technika wylapywania i wyplukiwania (Purge & Trap) i detekcja spektrometria mas (P&T-GC-MS) PN-EN ISO 15680:2008","categories":["water"],"row_index":566,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Zgierz","methodology_en":"Concentration of volatile organic compounds","parameters_en":[{"name":"Chloroform","range":"(1,0 – 200) μg/l"},{"name":"Bromodichloromethane","range":"(1,0 – 200) μg/l"},{"name":"Dibromochloromethane","range":"(1,0 – 200) μg/l"},{"name":"Bromoform","range":"(1,0 – 200) μg/l"},{"name":"Tetrachloromethane (carbon tetrachloride)","range":"(0,5 – 25) μg/l"},{"name":"Range","range":"1,2-dichloroetan (1,0 – 200) μg/l"},{"name":"Trichloroethene","range":"(1,0 – 200) μg/l"},{"name":"Tetrachloroethene","range":"(1,0 – 200) μg/l"},{"name":"Hexachlorobutadiene","range":"(0,10 – 12,5) μg/l"},{"name":"Vinyl chloride","range":"(0,10 – 12,5) μg/l"},{"name":"Benzene","range":"(0,5 – 100) μg/l"},{"name":"Toluene","range":"(0,5 – 100) μg/l"},{"name":"Ethylbenzene","range":"(1,0 – 200) μg/l"},{"name":"(m+p)-xylene","range":"(0,5 – 200) μg/l"},{"name":"o-xylene","range":"(0,5 – 200) μg/l"},{"name":"Sum of volatile organic compounds (calculated)"}],"search_en":"Water, Water intended for human consumption, Wastewater Concentration of volatile organic compounds Gas chromatography with purge and trap technique (Purge & Trap) and mass spectrometry detection (P&T-GC-MS) Environmental Analyses Laboratory Zgierz Chloroform Bromodichloromethane Dibromochloromethane Bromoform Tetrachloromethane (carbon tetrachloride) Range Trichloroethene Tetrachloroethene Hexachlorobutadiene Vinyl chloride Benzene Toluene Ethylbenzene (m+p)-xylene o-xylene Sum of volatile organic compounds (calculated) PN-EN ISO 15680:2008","technique_en":"Gas chromatography with purge and trap technique (Purge & Trap) and mass spectrometry detection (P&T-GC-MS)","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"三氯甲烷","range":"(1,0 – 200) μg/l"},{"name":"一溴二氯甲烷","range":"(1,0 – 200) μg/l"},{"name":"二溴一氯甲烷","range":"(1,0 – 200) μg/l"},{"name":"三溴甲烷","range":"(1,0 – 200) μg/l"},{"name":"Tetrachlorometan (czterochlorek węgla)","range":"(0,5 – 25) μg/l"},{"name":"范围","range":"1,2-dichloroetan (1,0 – 200) μg/l"},{"name":"三氯乙烯","range":"(1,0 – 200) μg/l"},{"name":"Tetrachloreten","range":"(1,0 – 200) μg/l"},{"name":"六氯丁二烯","range":"(0,10 – 12,5) μg/l"},{"name":"氯乙烯","range":"(0,10 – 12,5) μg/l"},{"name":"苯","range":"(0,5 – 100) μg/l"},{"name":"甲苯","range":"(0,5 – 100) μg/l"},{"name":"乙苯","range":"(1,0 – 200) μg/l"},{"name":"(间+对)-二甲苯","range":"(0,5 – 200) μg/l"},{"name":"邻二甲苯","range":"(0,5 – 200) μg/l"},{"name":"挥发性有机化合物总量（由计算得出）"}],"search_zh":"水、生活饮用水、废水 挥发性有机物浓度 环境分析实验室 Zgierz 三氯甲烷 一溴二氯甲烷 二溴一氯甲烷 三溴甲烷 范围 三氯乙烯 六氯丁二烯 氯乙烯 苯 甲苯 乙苯 (间+对)-二甲苯 邻二甲苯 挥发性有机化合物总量（由计算得出） PN-EN ISO 15680:2008","test_object_zh":"水、生活饮用水、废水","lab_section_zh":"环境分析实验室 Zgierz","methodology_zh":"挥发性有机物浓度"},{"_id":"6a7d76396040ebab2620d4ae","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 – 70) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (5 – 70) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 metoda C | PN-EN ISO 7887:2012/Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 metoda C","PN-EN ISO 7887:2012/Ap1:2015-06"],"lab_section":"Pracownia Analiz Środowiska Zgierz","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Barwa\nZakres (5 – 70) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C | PN-EN ISO 7887:2012/Ap1:2015-06 Woda, Woda do spozycia przez ludzi Barwa\nZakres (5 – 70) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C | PN-EN ISO 7887:2012/Ap1:2015-06","categories":["water"],"row_index":567,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Zgierz","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 – 70) mg/l Pt"}],"search_en":"Water, Water intended for human consumption Colour Spectrophotometric method Environmental Analyses Laboratory Zgierz Range PN-EN ISO 7887:2012 metoda C | PN-EN ISO 7887:2012/Ap1:2015-06","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 70) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 分光光度法 环境分析实验室 Zgierz 范围 PN-EN ISO 7887:2012 metoda C | PN-EN ISO 7887:2012/Ap1:2015-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"环境分析实验室 Zgierz"},{"_id":"6a7d76396040ebab2620d4af","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,20 – 800) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,20 – 800) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Pracownia Analiz Środowiska Zgierz","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Mętność\nZakres (0,20 – 800) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, Woda do spozycia przez ludzi Metnosc\nZakres (0,20 – 800) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":568,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Zgierz","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,20 – 800) NTU"}],"search_en":"Water, Water intended for human consumption Turbidity Nephelometric method Environmental Analyses Laboratory Zgierz Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 – 800) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 环境分析实验室 Zgierz 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水","lab_section_zh":"环境分析实验室 Zgierz"},{"_id":"6a7d76396040ebab2620d4b0","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(0,02 – 3,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (0,02 – 3,00) mg/l\nMetoda spektrofotometryczna","reference":"PB-464 wyd. I z dn. 01.06.2021 | na podstawie metody HACH 8008","norm_bases":["PB-464 wyd. I z dn. 01.06.2021","na podstawie metody HACH 8008"],"lab_section":"Pracownia Analiz Środowiska Zgierz","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie żelaza\nZakres (0,02 – 3,00) mg/l\nMetoda spektrofotometryczna PB-464 wyd. I z dn. 01.06.2021 | na podstawie metody HACH 8008 Woda, Woda do spozycia przez ludzi Stezenie zelaza\nZakres (0,02 – 3,00) mg/l\nMetoda spektrofotometryczna PB-464 wyd. I z dn. 01.06.2021 | na podstawie metody HACH 8008","categories":["water"],"row_index":569,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Zgierz","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(0,02 – 3,00) mg/l"}],"search_en":"Water, Water intended for human consumption Iron concentration Spectrophotometric method Environmental Analyses Laboratory Zgierz Range PB-464 wyd. I z dn. 01.06.2021 | na podstawie metody HACH 8008","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 3,00) mg/l"}],"search_zh":"水、生活饮用水 铁浓度 分光光度法 环境分析实验室 Zgierz 范围 PB-464 wyd. I z dn. 01.06.2021 | na podstawie metody HACH 8008","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"环境分析实验室 Zgierz"},{"_id":"6a7d76396040ebab2620d4b1","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,006 – 0,70) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (0,006 – 0,70) mg/l\nMetoda spektrofotometryczna","reference":"PB-465 wyd. I z dn. 01.06.2021 | na podstawie metody HACH 8149","norm_bases":["PB-465 wyd. I z dn. 01.06.2021","na podstawie metody HACH 8149"],"lab_section":"Pracownia Analiz Środowiska Zgierz","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie manganu\nZakres (0,006 – 0,70) mg/l\nMetoda spektrofotometryczna PB-465 wyd. I z dn. 01.06.2021 | na podstawie metody HACH 8149 Woda, Woda do spozycia przez ludzi Stezenie manganu\nZakres (0,006 – 0,70) mg/l\nMetoda spektrofotometryczna PB-465 wyd. I z dn. 01.06.2021 | na podstawie metody HACH 8149","categories":["water"],"row_index":570,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Zgierz","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(0,006 – 0,70) mg/l"}],"search_en":"Water, Water intended for human consumption Manganese concentration Spectrophotometric method Environmental Analyses Laboratory Zgierz Range PB-465 wyd. I z dn. 01.06.2021 | na podstawie metody HACH 8149","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,006 – 0,70) mg/l"}],"search_zh":"水、生活饮用水 锰浓度 分光光度法 环境分析实验室 Zgierz 范围 PB-465 wyd. I z dn. 01.06.2021 | na podstawie metody HACH 8149","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"环境分析实验室 Zgierz"},{"_id":"6a7d76396040ebab2620d4b2","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie glinu","parameters":[{"name":"Zakres","range":"(0,02 – 0,50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie glinu\nZakres (0,02 – 0,50) mg/l\nMetoda spektrofotometryczna","reference":"PB-466 wyd. I z dn. 01.06.2021 | na podstawie metody HACH LCK 301","norm_bases":["PB-466 wyd. I z dn. 01.06.2021","na podstawie metody HACH LCK 301"],"lab_section":"Pracownia Analiz Środowiska Zgierz","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie glinu\nZakres (0,02 – 0,50) mg/l\nMetoda spektrofotometryczna PB-466 wyd. I z dn. 01.06.2021 | na podstawie metody HACH LCK 301 Woda, Woda do spozycia przez ludzi Stezenie glinu\nZakres (0,02 – 0,50) mg/l\nMetoda spektrofotometryczna PB-466 wyd. I z dn. 01.06.2021 | na podstawie metody HACH LCK 301","categories":["water"],"row_index":571,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Zgierz","methodology_en":"Aluminium concentration","parameters_en":[{"name":"Range","range":"(0,02 – 0,50) mg/l"}],"search_en":"Water, Water intended for human consumption Aluminium concentration Spectrophotometric method Environmental Analyses Laboratory Zgierz Range PB-466 wyd. I z dn. 01.06.2021 | na podstawie metody HACH LCK 301","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,02 – 0,50) mg/l"}],"search_zh":"水、生活饮用水 铝浓度 分光光度法 环境分析实验室 Zgierz 范围 PB-466 wyd. I z dn. 01.06.2021 | na podstawie metody HACH LCK 301","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","methodology_zh":"铝浓度","lab_section_zh":"环境分析实验室 Zgierz"},{"_id":"6a7d76396040ebab2620d4b3","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(0,05 – 5,0) mmol/l"},{"name":"Zakres","range":"(5 – 500) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres:\nZakres (0,05 – 5,0) mmol/l\nZakres (5 – 500) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Pracownia Analiz Środowiska Zgierz","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres:\nZakres (0,05 – 5,0) mmol/l\nZakres (5 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres:\nZakres (0,05 – 5,0) mmol/l\nZakres (5 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":572,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Zgierz","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(0,05 – 5,0) mmol/l"},{"name":"Range","range":"(5 – 500) mg/l CaCO3"}],"search_en":"Water, Water intended for human consumption Total content of calcium and magnesium (total hardness) Titrimetric method Environmental Analyses Laboratory Zgierz Range Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(0,05 – 5,0) mmol/l"},{"name":"范围","range":"(5 – 500) mg/l CaCO3"}],"search_zh":"水、生活饮用水 钙与镁总量（总硬度） 滴定法 环境分析实验室 Zgierz 范围 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","lab_section_zh":"环境分析实验室 Zgierz"},{"_id":"6a7d76396040ebab2620d4b4","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,05 – 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,05 – 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-462 wyd. I z dn. 01.06.2021 | na podstawie metody HACH 8155","norm_bases":["PB-462 wyd. I z dn. 01.06.2021","na podstawie metody HACH 8155"],"lab_section":"Pracownia Analiz Środowiska Zgierz","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,05 – 1,0) mg/l\nMetoda spektrofotometryczna PB-462 wyd. I z dn. 01.06.2021 | na podstawie metody HACH 8155 Woda, Woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,05 – 1,0) mg/l\nMetoda spektrofotometryczna PB-462 wyd. I z dn. 01.06.2021 | na podstawie metody HACH 8155","categories":["water"],"row_index":573,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Zgierz","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,05 – 1,0) mg/l"}],"search_en":"Water, Water intended for human consumption Ammonium ion concentration Spectrophotometric method Environmental Analyses Laboratory Zgierz Range PB-462 wyd. I z dn. 01.06.2021 | na podstawie metody HACH 8155","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 1,0) mg/l"}],"search_zh":"水、生活饮用水 铵离子浓度 分光光度法 环境分析实验室 Zgierz 范围 PB-462 wyd. I z dn. 01.06.2021 | na podstawie metody HACH 8155","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"环境分析实验室 Zgierz"},{"_id":"6a7d76396040ebab2620d4b5","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,50 – 10) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,50 – 10) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Pracownia Analiz Środowiska Zgierz","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Indeks nadmanganianowy\nZakres (0,50 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, Woda do spozycia przez ludzi Indeks nadmanganianowy\nZakres (0,50 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":574,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Zgierz","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,50 – 10) mg/l O2"}],"search_en":"Water, Water intended for human consumption Permanganate index Titrimetric method Environmental Analyses Laboratory Zgierz Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,50 – 10) mg/l O2"}],"search_zh":"水、生活饮用水 高锰酸盐指数 滴定法 环境分析实验室 Zgierz 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","lab_section_zh":"环境分析实验室 Zgierz"},{"_id":"6a7d76396040ebab2620d4b6","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,50 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,50 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Pracownia Analiz Środowiska Zgierz","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu Kjeldahla\nZakres (0,50 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, Scieki Stezenie azotu Kjeldahla\nZakres (0,50 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":575,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Zgierz","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,50 – 1000) mg/l"}],"search_en":"Water, Wastewater Kjeldahl nitrogen concentration Titrimetric method Environmental Analyses Laboratory Zgierz Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water, Wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,50 – 1000) mg/l"}],"search_zh":"水、污水 凯氏氮浓度 滴定法 环境分析实验室 Zgierz 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、污水","lab_section_zh":"环境分析实验室 Zgierz"},{"_id":"6a7d76396040ebab2620d4b7","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,50 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,50 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Pracownia Analiz Środowiska Zgierz","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu amonowego\nZakres (0,50 – 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Woda, Scieki Stezenie azotu amonowego\nZakres (0,50 – 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":576,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Zgierz","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,50 – 1000) mg/l"}],"search_en":"Water, Wastewater Ammonium nitrogen concentration Titrimetric method Environmental Analyses Laboratory Zgierz Range PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Water, Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,50 – 1000) mg/l"}],"search_zh":"水、污水 氨氮浓度 滴定法 环境分析实验室 Zgierz 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"水、污水","lab_section_zh":"环境分析实验室 Zgierz"},{"_id":"6a7d76396040ebab2620d4b8","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,020 – 50,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,020 – 50,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt.7 + Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt.7 + Ap1:2010+Ap2:2010"],"lab_section":"Pracownia Analiz Środowiska Zgierz","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie fosforu ogólnego\nZakres (0,020 – 50,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt.7 + Ap1:2010+Ap2:2010 Woda, Scieki Stezenie fosforu ogolnego\nZakres (0,020 – 50,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt.7 + Ap1:2010+Ap2:2010","categories":["water"],"row_index":577,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Zgierz","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,020 – 50,0) mg/l"}],"search_en":"Water, Wastewater Total phosphorus concentration Spectrophotometric method Environmental Analyses Laboratory Zgierz Range PN-EN ISO 6878:2006 pkt.7 + Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,020 – 50,0) mg/l"}],"search_zh":"水、污水 总磷浓度 分光光度法 环境分析实验室 Zgierz 范围 PN-EN ISO 6878:2006 pkt.7 + Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、污水","lab_section_zh":"环境分析实验室 Zgierz"},{"_id":"6a7d76396040ebab2620d4b9","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 4000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 4000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia Analiz Środowiska Zgierz","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Zawiesiny ogólne\nZakres (2,0 – 4000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, Scieki Zawiesiny ogolne\nZakres (2,0 – 4000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":578,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Zgierz","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 4000) mg/l"}],"search_en":"Water, Wastewater Total suspended solids (TSS) Gravimetric method Environmental Analyses Laboratory Zgierz Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 4000) mg/l"}],"search_zh":"水、污水 总悬浮物 重量法 环境分析实验室 Zgierz 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、污水","lab_section_zh":"环境分析实验室 Zgierz"},{"_id":"6a7d76396040ebab2620d4ba","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr","parameters":[{"name":"Zakres","range":"(5,00 – 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (5,00 – 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia Analiz Środowiska Zgierz","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (5,00 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, Scieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (5,00 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":579,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Zgierz","methodology_en":"Chemical oxygen demand – COD-Cr","parameters_en":[{"name":"Range","range":"(5,00 – 10000) mg/l O2"}],"search_en":"Water, Wastewater Chemical oxygen demand – COD-Cr Spectrophotometric method Environmental Analyses Laboratory Zgierz Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(5,00 – 10000) mg/l O2"}],"search_zh":"水、污水 化学需氧量（COD-Cr） 分光光度法 环境分析实验室 Zgierz 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、污水","lab_section_zh":"环境分析实验室 Zgierz","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a7d76396040ebab2620d4bb","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu – BZT5","parameters":[{"name":"Zakres","range":"(1 – 6000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (1 – 6000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Pracownia Analiz Środowiska Zgierz","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (1 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Woda, Scieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (1 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":580,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Zgierz","methodology_en":"Biochemical oxygen demand – BOD5","parameters_en":[{"name":"Range","range":"(1 – 6000) mg/l O2"}],"search_en":"Water, Wastewater Biochemical oxygen demand – BOD5 Optical method Environmental Analyses Laboratory Zgierz Range PN-EN ISO 5815-1:2019-12","technique_en":"Optical method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(1 – 6000) mg/l O2"}],"search_zh":"水、污水 五日生化需氧量（BOD5） 光学法 环境分析实验室 Zgierz 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"水、污水","methodology_zh":"五日生化需氧量（BOD5）","lab_section_zh":"环境分析实验室 Zgierz"},{"_id":"6a7d76396040ebab2620d4bc","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Substancje rozpuszczone","parameters":[{"name":"Zakres","range":"(10 – 10000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje rozpuszczone\nZakres (10 – 10000) mg/l\nMetoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":"Pracownia Analiz Środowiska Zgierz","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Substancje rozpuszczone\nZakres (10 – 10000) mg/l\nMetoda wagowa PN-EN 15216:2022-03 Woda, Scieki Substancje rozpuszczone\nZakres (10 – 10000) mg/l\nMetoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":581,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Zgierz","methodology_en":"Dissolved solids","parameters_en":[{"name":"Range","range":"(10 – 10000) mg/l"}],"search_en":"Water, Wastewater Dissolved solids Gravimetric method Environmental Analyses Laboratory Zgierz Range PN-EN 15216:2022-03","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(10 – 10000) mg/l"}],"search_zh":"水、污水 溶解性固体 重量法 环境分析实验室 Zgierz 范围 PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"水、污水","lab_section_zh":"环境分析实验室 Zgierz","methodology_zh":"溶解性固体"},{"_id":"6a7d76396040ebab2620d4bd","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Sucha pozostałość Pozostałość po prażeniu","parameters":[{"name":"Zakres","range":"(10 – 10000) mg/l"},{"name":"Straty prażenia (z obliczeń)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość Pozostałość po prażeniu\nZakres:\nZakres (10 – 10000) mg/l\nStraty prażenia (z obliczeń)\nMetoda wagowa","reference":"PN-78/C-04541","norm_bases":["PN-78/C-04541"],"lab_section":"Pracownia Analiz Środowiska Zgierz","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Sucha pozostałość Pozostałość po prażeniu\nZakres:\nZakres (10 – 10000) mg/l\nStraty prażenia (z obliczeń)\nMetoda wagowa PN-78/C-04541 Woda, Scieki Sucha pozostalosc Pozostalosc po prazeniu\nZakres:\nZakres (10 – 10000) mg/l\nStraty prazenia (z obliczen)\nMetoda wagowa PN-78/C-04541","categories":["water"],"row_index":582,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Zgierz","methodology_en":"Dry residue Residue on ignition","parameters_en":[{"name":"Range","range":"(10 – 10000) mg/l"},{"name":"Loss on ignition (calculated)"}],"search_en":"Water, Wastewater Dry residue Residue on ignition Gravimetric method Environmental Analyses Laboratory Zgierz Range Loss on ignition (calculated) PN-78/C-04541","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(10 – 10000) mg/l"},{"name":"Straty prażenia (z obliczeń)"}],"search_zh":"水、污水 重量法 环境分析实验室 Zgierz 范围 PN-78/C-04541","technique_zh":"重量法","test_object_zh":"水、污水","lab_section_zh":"环境分析实验室 Zgierz"},{"_id":"6a7d76396040ebab2620d4be","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie siarczanów (VI)","parameters":[{"name":"Zakres","range":"(10 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów (VI)\nZakres (10 – 5000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Pracownia Analiz Środowiska Zgierz","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie siarczanów (VI)\nZakres (10 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Scieki Stezenie siarczanow (VI)\nZakres (10 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":583,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Zgierz","methodology_en":"Sulphate (VI) concentration","parameters_en":[{"name":"Range","range":"(10 – 5000) mg/l"}],"search_en":"Wastewater Sulphate (VI) concentration Gravimetric method Environmental Analyses Laboratory Zgierz Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(10 – 5000) mg/l"}],"search_zh":"污水 硫酸盐(VI)浓度 重量法 环境分析实验室 Zgierz 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"污水","lab_section_zh":"环境分析实验室 Zgierz","methodology_zh":"硫酸盐(VI)浓度"},{"_id":"6a7d76396040ebab2620d4bf","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Ścieki","methodology":"Zawiesiny łatwoopadające","parameters":[{"name":"Zakres","range":"(5 – 100) ml/l"}],"technique":"Metoda objętościowa","techniques":["Metoda objętościowa"],"computed":[],"activity":"Zawiesiny łatwoopadające\nZakres (5 – 100) ml/l\nMetoda objętościowa","reference":"PN-72/C-04559/03","norm_bases":["PN-72/C-04559/03"],"lab_section":"Pracownia Analiz Środowiska Zgierz","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Zawiesiny łatwoopadające\nZakres (5 – 100) ml/l\nMetoda objętościowa PN-72/C-04559/03 Scieki Zawiesiny latwoopadajace\nZakres (5 – 100) ml/l\nMetoda objetosciowa PN-72/C-04559/03","categories":["water"],"row_index":584,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Analyses Laboratory Zgierz","methodology_en":"Settleable solids","parameters_en":[{"name":"Range","range":"(5 – 100) ml/l"}],"search_en":"Wastewater Settleable solids Volumetric method Environmental Analyses Laboratory Zgierz Range PN-72/C-04559/03","technique_en":"Volumetric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(5 – 100) ml/l"}],"search_zh":"污水 易沉降悬浮物 容量法 环境分析实验室 Zgierz 范围 PN-72/C-04559/03","test_object_zh":"污水","technique_zh":"容量法","lab_section_zh":"环境分析实验室 Zgierz","methodology_zh":"易沉降悬浮物"},{"_id":"6a7d76396040ebab2620d4c0","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.6"],"lab_section":"Sekcja Poboru Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.6 Woda, Woda do spozycia przez ludzi, Woda na plywalniach Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem pkt. 4.4.6","categories":["water","microbiology"],"row_index":585,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sampling Section","methodology_en":"Sampling for microbiological testing","search_en":"Water, Water intended for human consumption, Swimming pool water Sampling for microbiological testing Sampling Section PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.6","test_object_en":"Water, Water intended for human consumption, Swimming pool water","methodology_zh":"微生物检测用样品采集","search_zh":"水、生活饮用水、游泳池水 微生物检测用样品采集 采样科 PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.6","test_object_zh":"水、生活饮用水、游泳池水","lab_section_zh":"采样科"},{"_id":"6a7d76396040ebab2620d4c1","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Powietrze","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":"Metoda sedymentacyjna i zderzeniowa (impakcyjna)","techniques":["Metoda sedymentacyjna i zderzeniowa (impakcyjna)"],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych\nMetoda sedymentacyjna i zderzeniowa (impakcyjna)","reference":"PB-250 wyd. 4 z dn. 31.10.2025","norm_bases":["PB-250 wyd. 4 z dn. 31.10.2025"],"lab_section":"Sekcja Poboru Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Powietrze Pobieranie próbek do badań mikrobiologicznych\nMetoda sedymentacyjna i zderzeniowa (impakcyjna) PB-250 wyd. 4 z dn. 31.10.2025 Powietrze Pobieranie probek do badan mikrobiologicznych\nMetoda sedymentacyjna i zderzeniowa (impakcyjna) PB-250 wyd. 4 z dn. 31.10.2025","categories":["environment","microbiology"],"row_index":586,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sampling Section","methodology_en":"Sampling for microbiological testing","search_en":"Air Sampling for microbiological testing Sedimentation and impingement (impaction) method Sampling Section PB-250 wyd. 4 z dn. 31.10.2025","technique_en":"Sedimentation and impingement (impaction) method","test_object_en":"Air","methodology_zh":"微生物检测用样品采集","search_zh":"空气 微生物检测用样品采集 采样科 PB-250 wyd. 4 z dn. 31.10.2025","test_object_zh":"空气","lab_section_zh":"采样科"},{"_id":"6a7d76396040ebab2620d4c2","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura","parameters":[{"name":"Zakres","range":"(4,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (4,0 – 50,0) °C","reference":"PN-ISO 5667-5:2017-10 | PN-77/C-04584","norm_bases":["PN-ISO 5667-5:2017-10","PN-77/C-04584"],"lab_section":"Sekcja Poboru Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (4,0 – 50,0) °C PN-ISO 5667-5:2017-10 | PN-77/C-04584 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych Temperatura\nZakres (4,0 – 50,0) °C PN-ISO 5667-5:2017-10 | PN-77/C-04584","categories":["water"],"row_index":587,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sampling Section","methodology_en":"Sampling for chemical and physical testing Temperature","parameters_en":[{"name":"Range","range":"(4,0 – 50,0) °C"}],"search_en":"Water intended for human consumption Sampling for chemical and physical testing Temperature Sampling Section Range PN-ISO 5667-5:2017-10 | PN-77/C-04584","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(4,0 – 50,0) °C"}],"search_zh":"生活饮用水 化学和物理检测采样 温度 采样科 范围 PN-ISO 5667-5:2017-10 | PN-77/C-04584","test_object_zh":"生活饮用水","lab_section_zh":"采样科","methodology_zh":"化学和物理检测采样 温度"},{"_id":"6a7d76396040ebab2620d4c3","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda podziemna","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura","parameters":[{"name":"Zakres","range":"(4,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (4,0 – 50,0) °C","reference":"PN-ISO 5667-11:2017-10 | PN-77/C-04584","norm_bases":["PN-ISO 5667-11:2017-10","PN-77/C-04584"],"lab_section":"Sekcja Poboru Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda podziemna Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (4,0 – 50,0) °C PN-ISO 5667-11:2017-10 | PN-77/C-04584 Woda podziemna Pobieranie probek do badan chemicznych i fizycznych Temperatura\nZakres (4,0 – 50,0) °C PN-ISO 5667-11:2017-10 | PN-77/C-04584","categories":["water"],"row_index":588,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sampling Section","methodology_en":"Sampling for chemical and physical testing Temperature","parameters_en":[{"name":"Range","range":"(4,0 – 50,0) °C"}],"search_en":"Groundwater Sampling for chemical and physical testing Temperature Sampling Section Range PN-ISO 5667-11:2017-10 | PN-77/C-04584","test_object_en":"Groundwater","parameters_zh":[{"name":"范围","range":"(4,0 – 50,0) °C"}],"search_zh":"地下水 化学和物理检测采样 温度 采样科 范围 PN-ISO 5667-11:2017-10 | PN-77/C-04584","lab_section_zh":"采样科","methodology_zh":"化学和物理检测采样 温度","test_object_zh":"地下水"},{"_id":"6a7d76396040ebab2620d4c4","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda powierzchniowa","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura","parameters":[{"name":"Zakres","range":"(4,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (4,0 – 50,0) °C","reference":"PN-ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5;7.6 | PN-77/C-04584","norm_bases":["PN-ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5;7.6","PN-77/C-04584"],"lab_section":"Sekcja Poboru Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda powierzchniowa Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (4,0 – 50,0) °C PN-ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5;7.6 | PN-77/C-04584 Woda powierzchniowa Pobieranie probek do badan chemicznych i fizycznych Temperatura\nZakres (4,0 – 50,0) °C PN-ISO 5667-6:2016-12 z wylaczeniem pkt. 7.5;7.6 | PN-77/C-04584","categories":["water"],"row_index":589,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sampling Section","methodology_en":"Sampling for chemical and physical testing Temperature","parameters_en":[{"name":"Range","range":"(4,0 – 50,0) °C"}],"search_en":"Surface water Sampling for chemical and physical testing Temperature Sampling Section Range PN-ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5;7.6 | PN-77/C-04584","test_object_en":"Surface water","parameters_zh":[{"name":"范围","range":"(4,0 – 50,0) °C"}],"search_zh":"地表水 化学和物理检测采样 温度 采样科 范围 PN-ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5;7.6 | PN-77/C-04584","test_object_zh":"地表水","lab_section_zh":"采样科","methodology_zh":"化学和物理检测采样 温度"},{"_id":"6a7d76396040ebab2620d4c5","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura"},{"name":"Zakres","range":"(4,0 – 50,0) °C"}],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (4,0 – 50,0) °C\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":"Sekcja Poboru Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (4,0 – 50,0) °C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (4,0 – 50,0) °C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":590,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sampling Section","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature"},{"name":"Range","range":"(4,0 – 50,0) °C"}],"search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method Sampling Section Temperature Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"温度"},{"name":"范围","range":"(4,0 – 50,0) °C"}],"search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 采样科 温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_zh":"手动法；自动法","test_object_zh":"污水","lab_section_zh":"采样科"},{"_id":"6a7d76396040ebab2620d4c6","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chloru całkowitego (ogólnego)","parameters":[{"name":"Zakres","range":"(0,05 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru całkowitego (ogólnego)\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-480 wyd. I z dn. 24.06.2021 na podstawie metody HACH nr 8167","norm_bases":["PB-480 wyd. I z dn. 24.06.2021 na podstawie metody HACH nr 8167"],"lab_section":"Sekcja Poboru Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chloru całkowitego (ogólnego)\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna PB-480 wyd. I z dn. 24.06.2021 na podstawie metody HACH nr 8167 Scieki Stezenie chloru calkowitego (ogolnego)\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna PB-480 wyd. I z dn. 24.06.2021 na podstawie metody HACH nr 8167","categories":["water"],"row_index":591,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sampling Section","methodology_en":"Total (overall) chlorine concentration","parameters_en":[{"name":"Range","range":"(0,05 – 2,0) mg/l"}],"search_en":"Wastewater Total (overall) chlorine concentration Spectrophotometric method Sampling Section Range PB-480 wyd. I z dn. 24.06.2021 na podstawie metody HACH nr 8167","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,05 – 2,0) mg/l"}],"search_zh":"污水 分光光度法 采样科 范围 PB-480 wyd. I z dn. 24.06.2021 na podstawie metody HACH nr 8167","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"采样科"},{"_id":"6a7d76396040ebab2620d4c7","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,05 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-480 wyd. I z dn. 24.06.2021 na podstawie metody HACH nr 8021","norm_bases":["PB-480 wyd. I z dn. 24.06.2021 na podstawie metody HACH nr 8021"],"lab_section":"Sekcja Poboru Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chloru wolnego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna PB-480 wyd. I z dn. 24.06.2021 na podstawie metody HACH nr 8021 Scieki Stezenie chloru wolnego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna PB-480 wyd. I z dn. 24.06.2021 na podstawie metody HACH nr 8021","categories":["water"],"row_index":592,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sampling Section","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,05 – 2,0) mg/l"}],"search_en":"Wastewater Free chlorine concentration Spectrophotometric method Sampling Section Range PB-480 wyd. I z dn. 24.06.2021 na podstawie metody HACH nr 8021","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 2,0) mg/l"}],"search_zh":"污水 游离氯浓度 分光光度法 采样科 范围 PB-480 wyd. I z dn. 24.06.2021 na podstawie metody HACH nr 8021","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"采样科"},{"_id":"6a7d76396040ebab2620d4c8","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Odpady O) kod: 19 08 01, 19 08 02, 19 08 05","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PB-206 wyd. II z dn. 11.04.2019","norm_bases":["PB-206 wyd. II z dn. 11.04.2019"],"lab_section":"Sekcja Poboru Próbek","lab_address":null,"regulatory_area":"O) Kody odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O) kod: 19 08 01, 19 08 02, 19 08 05 Pobieranie próbek do badań chemicznych i fizycznych PB-206 wyd. II z dn. 11.04.2019 Odpady O) kod: 19 08 01, 19 08 02, 19 08 05 Pobieranie probek do badan chemicznych i fizycznych PB-206 wyd. II z dn. 11.04.2019","categories":["environment"],"row_index":593,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sampling Section","methodology_en":"Sampling for chemical and physical testing","regulatory_area_en":"O) Waste codes given according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Waste O) code: 19 08 01, 19 08 02, 19 08 05 Sampling for chemical and physical testing Sampling Section O) Waste codes given according to the Regulation of the Minister of Climate on the waste catalogue. PB-206 wyd. II z dn. 11.04.2019","test_object_en":"Waste O) code: 19 08 01, 19 08 02, 19 08 05","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 采样科 O) 废物代码依据气候部长关于废物名录的条例给出。 PB-206 wyd. II z dn. 11.04.2019","lab_section_zh":"采样科","regulatory_area_zh":"O) 废物代码依据气候部长关于废物名录的条例给出。"},{"_id":"6a7d76396040ebab2620d4c9","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O) kod: 19 08 05","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-13:2011","norm_bases":["PN-ISO 5667-13:2011"],"lab_section":"Sekcja Poboru Próbek","lab_address":null,"regulatory_area":"O) Kody odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Osady ściekowe, Odpady O) kod: 19 08 05 Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-13:2011 Osady sciekowe, Odpady O) kod: 19 08 05 Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-13:2011","categories":["water","environment"],"row_index":594,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sampling Section","methodology_en":"Sampling for chemical and physical testing","regulatory_area_en":"O) Waste codes given according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Sewage sludge, Waste O) code: 19 08 05 Sampling for chemical and physical testing Sampling Section O) Waste codes given according to the Regulation of the Minister of Climate on the waste catalogue. PN-ISO 5667-13:2011","test_object_en":"Sewage sludge, Waste O) code: 19 08 05","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 采样科 O) 废物代码依据气候部长关于废物名录的条例给出。 PN-ISO 5667-13:2011","lab_section_zh":"采样科","regulatory_area_zh":"O) 废物代码依据气候部长关于废物名录的条例给出。"},{"_id":"6a7d76396040ebab2620d4ca","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Pobieranie próbek do badań mikrobiologicznych i biologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych i biologicznych","reference":"PB-471 wyd. 1 z dn. 26.11.2021","norm_bases":["PB-471 wyd. 1 z dn. 26.11.2021"],"lab_section":"Sekcja Poboru Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Pobieranie próbek do badań mikrobiologicznych i biologicznych PB-471 wyd. 1 z dn. 26.11.2021 Osady sciekowe Pobieranie probek do badan mikrobiologicznych i biologicznych PB-471 wyd. 1 z dn. 26.11.2021","categories":["water","microbiology"],"row_index":595,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sampling Section","methodology_en":"Sampling for microbiological and biological testing","search_en":"Sewage sludge Sampling for microbiological and biological testing Sampling Section PB-471 wyd. 1 z dn. 26.11.2021","test_object_en":"Sewage sludge","search_zh":"污泥 采样科 PB-471 wyd. 1 z dn. 26.11.2021","test_object_zh":"污泥","lab_section_zh":"采样科"},{"_id":"6a7d76396040ebab2620d4cb","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Gleba","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-R-04031:1997 | PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","norm_bases":["PN-R-04031:1997","PN-ISO 10381-4:2007","PN-ISO 10381-5:2009"],"lab_section":"Sekcja Poboru Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Pobieranie próbek do badań chemicznych i fizycznych PN-R-04031:1997 | PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009 Gleba Pobieranie probek do badan chemicznych i fizycznych PN-R-04031:1997 | PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","categories":["environment"],"row_index":596,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sampling Section","methodology_en":"Sampling for chemical and physical testing","search_en":"Soil Sampling for chemical and physical testing Sampling Section PN-R-04031:1997 | PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","test_object_en":"Soil","methodology_zh":"化学与物理检测用样品采集","search_zh":"土壤 化学与物理检测用样品采集 采样科 PN-R-04031:1997 | PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","test_object_zh":"土壤","lab_section_zh":"采样科"},{"_id":"6a7d76396040ebab2620d4cc","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Grunty","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","norm_bases":["PN-ISO 10381-4:2007","PN-ISO 10381-5:2009"],"lab_section":"Sekcja Poboru Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009 Grunty Pobieranie probek do badan chemicznych i fizycznych PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","categories":["other"],"row_index":597,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sampling Section","methodology_en":"Sampling for chemical and physical testing","search_en":"Ground Sampling for chemical and physical testing Sampling Section PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","test_object_en":"Ground","methodology_zh":"化学与物理检测用样品采集","search_zh":"土体 化学与物理检测用样品采集 采样科 PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","test_object_zh":"土体","lab_section_zh":"采样科"},{"_id":"6a7d76396040ebab2620d4cd","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Produkty rolne","methodology":"Pobieranie próbek do badań na obecność środków ochrony roślin","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań na obecność środków ochrony roślin","reference":"Rozporządzenie Ministra Rolnictwa i Rozwoju Wsi z dnia 3 września 2020 r. (Dz.U. 2020 poz. 1589)","norm_bases":["Rozporządzenie Ministra Rolnictwa i Rozwoju Wsi z dnia 3 września 2020 r. (Dz.U. 2020 poz. 1589)"],"lab_section":"Sekcja Poboru Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Produkty rolne Pobieranie próbek do badań na obecność środków ochrony roślin Rozporządzenie Ministra Rolnictwa i Rozwoju Wsi z dnia 3 września 2020 r. (Dz.U. 2020 poz. 1589) Produkty rolne Pobieranie probek do badan na obecnosc srodkow ochrony roslin Rozporzadzenie Ministra Rolnictwa i Rozwoju Wsi z dnia 3 wrzesnia 2020 r. (Dz.U. 2020 poz. 1589)","categories":["other"],"row_index":598,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sampling Section","methodology_en":"Sampling for testing for the presence of plant protection products","search_en":"Agricultural products Sampling for testing for the presence of plant protection products Sampling Section Rozporządzenie Ministra Rolnictwa i Rozwoju Wsi z dnia 3 września 2020 r. (Dz.U. 2020 poz. 1589)","test_object_en":"Agricultural products","lab_section_zh":"采样科","search_zh":"采样科 Rozporządzenie Ministra Rolnictwa i Rozwoju Wsi z dnia 3 września 2020 r. (Dz.U. 2020 poz. 1589)"},{"_id":"6a7d76396040ebab2620d4ce","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością i kosmetykami","methodology":"Pobieranie próbek z powierzchni z użyciem płytek kontaktowych i wymazów do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek z powierzchni z użyciem płytek kontaktowych i wymazów do badań mikrobiologicznych","reference":"PN-EN ISO 18593:2018-08","norm_bases":["PN-EN ISO 18593:2018-08"],"lab_section":"Sekcja Poboru Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i kosmetyków oraz obrotu żywnością i kosmetykami Pobieranie próbek z powierzchni z użyciem płytek kontaktowych i wymazów do badań mikrobiologicznych PN-EN ISO 18593:2018-08 Probki srodowiskowe z obszarow produkcji zywnosci i kosmetykow oraz obrotu zywnoscia i kosmetykami Pobieranie probek z powierzchni z uzyciem plytek kontaktowych i wymazow do badan mikrobiologicznych PN-EN ISO 18593:2018-08","categories":["food","environment","microbiology","pharma"],"row_index":599,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sampling Section","methodology_en":"Surface sampling using contact plates and swabs for microbiological testing","search_en":"Environmental samples from food and cosmetics production and distribution areas Surface sampling using contact plates and swabs for microbiological testing Sampling Section PN-EN ISO 18593:2018-08","test_object_en":"Environmental samples from food and cosmetics production and distribution areas","lab_section_zh":"采样科","search_zh":"采样科 PN-EN ISO 18593:2018-08"},{"_id":"6a7d76396040ebab2620d4cf","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura","parameters":[{"name":"Zakres","range":"(4,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (4,0 – 50,0) °C","reference":"PB-378 wyd. 3 z dn. 09.02.2026 | PN-77/C-04584","norm_bases":["PB-378 wyd. 3 z dn. 09.02.2026","PN-77/C-04584"],"lab_section":"Sekcja Poboru Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (4,0 – 50,0) °C PB-378 wyd. 3 z dn. 09.02.2026 | PN-77/C-04584 Woda na plywalniach Pobieranie probek do badan chemicznych i fizycznych Temperatura\nZakres (4,0 – 50,0) °C PB-378 wyd. 3 z dn. 09.02.2026 | PN-77/C-04584","categories":["water"],"row_index":600,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sampling Section","methodology_en":"Sampling for chemical and physical testing Temperature","parameters_en":[{"name":"Range","range":"(4,0 – 50,0) °C"}],"search_en":"Swimming pool water Sampling for chemical and physical testing Temperature Sampling Section Range PB-378 wyd. 3 z dn. 09.02.2026 | PN-77/C-04584","test_object_en":"Swimming pool water","parameters_zh":[{"name":"范围","range":"(4,0 – 50,0) °C"}],"search_zh":"游泳池水 化学和物理检测采样 温度 采样科 范围 PB-378 wyd. 3 z dn. 09.02.2026 | PN-77/C-04584","test_object_zh":"游泳池水","lab_section_zh":"采样科","methodology_zh":"化学和物理检测采样 温度"},{"_id":"6a7d76396040ebab2620d4d0","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"Potencjał utleniająco-redukujący (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl","parameters":[{"name":"Zakres","range":"(200 – 1000) mV"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Potencjał utleniająco-redukujący (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (200 – 1000) mV\nMetoda potencjometryczna","reference":"PB-377 wyd. II z dn. 30.03.2020","norm_bases":["PB-377 wyd. II z dn. 30.03.2020"],"lab_section":"Sekcja Poboru Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) Potencjał utleniająco-redukujący (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (200 – 1000) mV\nMetoda potencjometryczna PB-377 wyd. II z dn. 30.03.2020 Woda (w tym woda na plywalniach) Potencjal utleniajaco-redukujacy (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (200 – 1000) mV\nMetoda potencjometryczna PB-377 wyd. II z dn. 30.03.2020","categories":["water"],"row_index":601,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sampling Section","methodology_en":"Oxidation-reduction (redox) potential vs. Ag/AgCl 3,5 mol/l KCl","parameters_en":[{"name":"Range","range":"(200 – 1000) mV"}],"search_en":"Water (including swimming pool water) Oxidation-reduction (redox) potential vs. Ag/AgCl 3,5 mol/l KCl Potentiometric method Sampling Section Range PB-377 wyd. II z dn. 30.03.2020","technique_en":"Potentiometric method","test_object_en":"Water (including swimming pool water)","parameters_zh":[{"name":"范围","range":"(200 – 1000) mV"}],"search_zh":"水（含游泳池水） 氧化还原电位（redoks），相对于 Ag/AgCl 3,5 mol/l KCl 电位法 采样科 范围 PB-377 wyd. II z dn. 30.03.2020","technique_zh":"电位法","test_object_zh":"水（含游泳池水）","lab_section_zh":"采样科","methodology_zh":"氧化还原电位（redoks），相对于 Ag/AgCl 3,5 mol/l KCl"},{"_id":"6a7d76396040ebab2620d4d1","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"Stężenie chloramin","parameters":[{"name":"Zakres","range":"(0,05 – 4,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloramin\nZakres (0,05 – 4,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-469 wyd. I z dn. 08.01.2021 | na podstawie metody HACH nr 10200","norm_bases":["PB-469 wyd. I z dn. 08.01.2021","na podstawie metody HACH nr 10200"],"lab_section":"Sekcja Poboru Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) Stężenie chloramin\nZakres (0,05 – 4,0) mg/l\nMetoda spektrofotometryczna PB-469 wyd. I z dn. 08.01.2021 | na podstawie metody HACH nr 10200 Woda (w tym woda na plywalniach) Stezenie chloramin\nZakres (0,05 – 4,0) mg/l\nMetoda spektrofotometryczna PB-469 wyd. I z dn. 08.01.2021 | na podstawie metody HACH nr 10200","categories":["water"],"row_index":602,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sampling Section","methodology_en":"Chloramine concentration","parameters_en":[{"name":"Range","range":"(0,05 – 4,0) mg/l"}],"search_en":"Water (including swimming pool water) Chloramine concentration Spectrophotometric method Sampling Section Range PB-469 wyd. I z dn. 08.01.2021 | na podstawie metody HACH nr 10200","technique_en":"Spectrophotometric method","test_object_en":"Water (including swimming pool water)","parameters_zh":[{"name":"范围","range":"(0,05 – 4,0) mg/l"}],"search_zh":"水（含游泳池水） 分光光度法 采样科 范围 PB-469 wyd. I z dn. 08.01.2021 | na podstawie metody HACH nr 10200","technique_zh":"分光光度法","test_object_zh":"水（含游泳池水）","lab_section_zh":"采样科"},{"_id":"6a7d76396040ebab2620d4d2","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,05 – 5,0) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,05 – 5,0) mg/l\nMetoda kolorymetryczna","reference":"PB-358 wyd. III z dn. 30.03.2020 | na podstawie metody Palintest | PB-566 wyd. 1 z dn. 18.11.2024","norm_bases":["PB-358 wyd. III z dn. 30.03.2020","na podstawie metody Palintest","PB-566 wyd. 1 z dn. 18.11.2024"],"lab_section":"Sekcja Poboru Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) Stężenie chloru wolnego\nZakres (0,05 – 5,0) mg/l\nMetoda kolorymetryczna PB-358 wyd. III z dn. 30.03.2020 | na podstawie metody Palintest | PB-566 wyd. 1 z dn. 18.11.2024 Woda (w tym woda na plywalniach) Stezenie chloru wolnego\nZakres (0,05 – 5,0) mg/l\nMetoda kolorymetryczna PB-358 wyd. III z dn. 30.03.2020 | na podstawie metody Palintest | PB-566 wyd. 1 z dn. 18.11.2024","categories":["water"],"row_index":603,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sampling Section","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,05 – 5,0) mg/l"}],"search_en":"Water (including swimming pool water) Free chlorine concentration Colorimetric method Sampling Section Range PB-358 wyd. III z dn. 30.03.2020 | na podstawie metody Palintest | PB-566 wyd. 1 z dn. 18.11.2024","technique_en":"Colorimetric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 5,0) mg/l"}],"search_zh":"水（含游泳池水） 游离氯浓度 比色法 采样科 范围 PB-358 wyd. III z dn. 30.03.2020 | na podstawie metody Palintest | PB-566 wyd. 1 z dn. 18.11.2024","technique_zh":"比色法","test_object_zh":"水（含游泳池水）","lab_section_zh":"采样科"},{"_id":"6a7d76396040ebab2620d4d3","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"Stężenie chloru ogólnego/całkowitego","parameters":[{"name":"Zakres","range":"(0,05 – 5,0) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Stężenie chloru ogólnego/całkowitego\nZakres (0,05 – 5,0) mg/l\nMetoda kolorymetryczna","reference":"PB-358 wyd. III z dn. 30.03.2020 | na podstawie metody Palintest | PB-566 wyd. 1 z dn. 18.11.2024","norm_bases":["PB-358 wyd. III z dn. 30.03.2020","na podstawie metody Palintest","PB-566 wyd. 1 z dn. 18.11.2024"],"lab_section":"Sekcja Poboru Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) Stężenie chloru ogólnego/całkowitego\nZakres (0,05 – 5,0) mg/l\nMetoda kolorymetryczna PB-358 wyd. III z dn. 30.03.2020 | na podstawie metody Palintest | PB-566 wyd. 1 z dn. 18.11.2024 Woda (w tym woda na plywalniach) Stezenie chloru ogolnego/calkowitego\nZakres (0,05 – 5,0) mg/l\nMetoda kolorymetryczna PB-358 wyd. III z dn. 30.03.2020 | na podstawie metody Palintest | PB-566 wyd. 1 z dn. 18.11.2024","categories":["water"],"row_index":604,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sampling Section","methodology_en":"Total chlorine concentration","parameters_en":[{"name":"Range","range":"(0,05 – 5,0) mg/l"}],"search_en":"Water (including swimming pool water) Total chlorine concentration Colorimetric method Sampling Section Range PB-358 wyd. III z dn. 30.03.2020 | na podstawie metody Palintest | PB-566 wyd. 1 z dn. 18.11.2024","technique_en":"Colorimetric method","test_object_en":"Water (including swimming pool water)","parameters_zh":[{"name":"范围","range":"(0,05 – 5,0) mg/l"}],"search_zh":"水（含游泳池水） 总氯浓度 比色法 采样科 范围 PB-358 wyd. III z dn. 30.03.2020 | na podstawie metody Palintest | PB-566 wyd. 1 z dn. 18.11.2024","technique_zh":"比色法","test_object_zh":"水（含游泳池水）","lab_section_zh":"采样科","methodology_zh":"总氯浓度"},{"_id":"6a7d76396040ebab2620d4d4","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"Stężenie chloru związanego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chloru związanego (z obliczeń)","reference":"PB-358 wyd. III z dn. 30.03.2020 | na podstawie metody Palintest | PB-566 wyd. 1 z dn. 18.11.2024","norm_bases":["PB-358 wyd. III z dn. 30.03.2020","na podstawie metody Palintest","PB-566 wyd. 1 z dn. 18.11.2024"],"lab_section":"Sekcja Poboru Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) Stężenie chloru związanego (z obliczeń) PB-358 wyd. III z dn. 30.03.2020 | na podstawie metody Palintest | PB-566 wyd. 1 z dn. 18.11.2024 Woda (w tym woda na plywalniach) Stezenie chloru zwiazanego (z obliczen) PB-358 wyd. III z dn. 30.03.2020 | na podstawie metody Palintest | PB-566 wyd. 1 z dn. 18.11.2024","categories":["water"],"row_index":605,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sampling Section","methodology_en":"Combined chlorine concentration (calculated)","search_en":"Water (including swimming pool water) Combined chlorine concentration (calculated) Sampling Section PB-358 wyd. III z dn. 30.03.2020 | na podstawie metody Palintest | PB-566 wyd. 1 z dn. 18.11.2024","test_object_en":"Water (including swimming pool water)","methodology_zh":"化合氯浓度（计算值）","search_zh":"水（含游泳池水） 化合氯浓度（计算值） 采样科 PB-358 wyd. III z dn. 30.03.2020 | na podstawie metody Palintest | PB-566 wyd. 1 z dn. 18.11.2024","test_object_zh":"水（含游泳池水）","lab_section_zh":"采样科"},{"_id":"6a7d76396040ebab2620d4d5","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"Stężenie ozonu","parameters":[{"name":"Zakres","range":"(0,03 – 0,75) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ozonu\nZakres (0,03 – 0,75) mg/l\nMetoda spektrofotometryczna","reference":"PB-468 wyd. I z dn.03.06.2021 | na podstawie metody HACH nr 8311","norm_bases":["PB-468 wyd. I z dn.03.06.2021","na podstawie metody HACH nr 8311"],"lab_section":"Sekcja Poboru Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) Stężenie ozonu\nZakres (0,03 – 0,75) mg/l\nMetoda spektrofotometryczna PB-468 wyd. I z dn.03.06.2021 | na podstawie metody HACH nr 8311 Woda (w tym woda na plywalniach) Stezenie ozonu\nZakres (0,03 – 0,75) mg/l\nMetoda spektrofotometryczna PB-468 wyd. I z dn.03.06.2021 | na podstawie metody HACH nr 8311","categories":["water"],"row_index":606,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sampling Section","methodology_en":"Ozone concentration","parameters_en":[{"name":"Range","range":"(0,03 – 0,75) mg/l"}],"search_en":"Water (including swimming pool water) Ozone concentration Spectrophotometric method Sampling Section Range PB-468 wyd. I z dn.03.06.2021 | na podstawie metody HACH nr 8311","technique_en":"Spectrophotometric method","test_object_en":"Water (including swimming pool water)","parameters_zh":[{"name":"范围","range":"(0,03 – 0,75) mg/l"}],"search_zh":"水（含游泳池水） 臭氧浓度 分光光度法 采样科 范围 PB-468 wyd. I z dn.03.06.2021 | na podstawie metody HACH nr 8311","technique_zh":"分光光度法","test_object_zh":"水（含游泳池水）","lab_section_zh":"采样科","methodology_zh":"臭氧浓度"},{"_id":"6a7d76396040ebab2620d4d6","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Sekcja Poboru Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":607,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sampling Section","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Water, wastewater pH Potentiometric method Sampling Section Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"水、废水 pH 值 电位法 采样科 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、废水","lab_section_zh":"采样科"},{"_id":"6a7d76396040ebab2620d4d7","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,2 – 15) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,2 – 15) mg/l O2\nMetoda optyczna","reference":"ISO 17289:2014","norm_bases":["ISO 17289:2014"],"lab_section":"Sekcja Poboru Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie tlenu rozpuszczonego\nZakres (0,2 – 15) mg/l O2\nMetoda optyczna ISO 17289:2014 Woda, Woda do spozycia przez ludzi, Scieki Stezenie tlenu rozpuszczonego\nZakres (0,2 – 15) mg/l O2\nMetoda optyczna ISO 17289:2014","categories":["water"],"row_index":608,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sampling Section","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(0,2 – 15) mg/l O2"}],"search_en":"Water, Water intended for human consumption, Wastewater Dissolved oxygen concentration Optical method Sampling Section Range ISO 17289:2014","technique_en":"Optical method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(0,2 – 15) mg/l O2"}],"search_zh":"水、生活饮用水、废水 溶解氧浓度 光学法 采样科 范围 ISO 17289:2014","technique_zh":"光学法","test_object_zh":"水、生活饮用水、废水","methodology_zh":"溶解氧浓度","lab_section_zh":"采样科"},{"_id":"6a7d76396040ebab2620d4d8","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Odpady DAB-11: - Osady i odpady mineralne (I); - Odpady budowlane (III); - Odpady z przetwarzania odpadów (VI); - Osady ściekowe (IX); - Żużle, popioły i pyły paleniskowe (XI); - Inne odpady komunalne, w tym odpady zmieszane (XXVIII) - Osady z procesów przemysłowych (VII) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII)","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PB-206 wyd. II z dn. 11.04.2019","norm_bases":["PB-206 wyd. II z dn. 11.04.2019"],"lab_section":"Sekcja Poboru Próbek","lab_address":null,"regulatory_area":"Pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277) - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015, poz. 257) DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.","flexible":false,"search_text":"Odpady DAB-11: - Osady i odpady mineralne (I); - Odpady budowlane (III); - Odpady z przetwarzania odpadów (VI); - Osady ściekowe (IX); - Żużle, popioły i pyły paleniskowe (XI); - Inne odpady komunalne, w tym odpady zmieszane (XXVIII) - Osady z procesów przemysłowych (VII) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) Pobieranie próbek do badań chemicznych i fizycznych PB-206 wyd. II z dn. 11.04.2019 Odpady DAB-11: - Osady i odpady mineralne (I); - Odpady budowlane (III); - Odpady z przetwarzania odpadow (VI); - Osady sciekowe (IX); - Zuzle, popioly i pyly paleniskowe (XI); - Inne odpady komunalne, w tym odpady zmieszane (XXVIII) - Osady z procesow przemyslowych (VII) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) Pobieranie probek do badan chemicznych i fizycznych PB-206 wyd. II z dn. 11.04.2019","categories":["environment","water","materials","construction"],"row_index":609,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sampling Section","methodology_en":"Sampling for chemical and physical testing","regulatory_area_en":"Sampling carried out for the purposes of the regulated area covered by: - the Regulation of the Minister of Economy of 16 July 2015 on the acceptance of waste for landfill (Dz. U. z 2015, poz. 1277) - the Regulation of the Minister of the Environment of 6 February 2015 on municipal sewage sludge (Dz. U. z 2015, poz. 257) DAB-11) Waste codes according to the Regulation of the Minister of Climate on the waste catalogue for the validation group are given in Annex No 1 to DAB-11.","search_en":"Waste DAB-11: - Mineral sludges and wastes (I); - Construction waste (III); - Waste from waste treatment (VI); - Sewage sludge (IX); - Slags, ashes and furnace dusts (XI); - Other municipal waste, including mixed waste (XXVIII) - Sludges from industrial processes (VII) - Waste from the processing of crude oil, natural gas and coal (XXI) - Plastics (XXV) - Wood (XXVI) - Leather and textiles (XXVII) Sampling for chemical and physical testing Sampling Section Sampling carried out for the purposes of the regulated area covered by: - the Regulation of the Minister of Economy of 16 July 2015 on the acceptance of waste for landfill (Dz. U. z 2015, poz. 1277) - the Regulation of the Minister of the Environment of 6 February 2015 on municipal sewage sludge (Dz. U. z 2015, poz. 257) DAB-11) Waste codes according to the Regulation of the Minister of Climate on the waste catalogue for the validation group are given in Annex No 1 to DAB-11. PB-206 wyd. II z dn. 11.04.2019","test_object_en":"Waste DAB-11: - Mineral sludges and wastes (I); - Construction waste (III); - Waste from waste treatment (VI); - Sewage sludge (IX); - Slags, ashes and furnace dusts (XI); - Other municipal waste, including mixed waste (XXVIII) - Sludges from industrial processes (VII) - Waste from the processing of crude oil, natural gas and coal (XXI) - Plastics (XXV) - Wood (XXVI) - Leather and textiles (XXVII)","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 采样科 PB-206 wyd. II z dn. 11.04.2019","lab_section_zh":"采样科"},{"_id":"6a7d76396040ebab2620d4d9","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Nasiona oleiste","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(0,1 – 20) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (0,1 – 20) %\nMetoda wagowa","reference":"PN-EN ISO 658:2004 | ISO 658:2002","norm_bases":["PN-EN ISO 658:2004","ISO 658:2002"],"lab_section":"Sekcja Uśredniania Próbek i Analiz Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nasiona oleiste Zawartość zanieczyszczeń\nZakres (0,1 – 20) %\nMetoda wagowa PN-EN ISO 658:2004 | ISO 658:2002 Nasiona oleiste Zawartosc zanieczyszczen\nZakres (0,1 – 20) %\nMetoda wagowa PN-EN ISO 658:2004 | ISO 658:2002","categories":["other"],"row_index":610,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sample Homogenisation and Physical Analyses Section","methodology_en":"Impurity content","parameters_en":[{"name":"Range","range":"(0,1 – 20) %"}],"search_en":"Oilseeds Impurity content Gravimetric method Sample Homogenisation and Physical Analyses Section Range PN-EN ISO 658:2004 | ISO 658:2002","technique_en":"Gravimetric method","test_object_en":"Oilseeds","parameters_zh":[{"name":"范围","range":"(0,1 – 20) %"}],"search_zh":"油料种子 杂质含量 重量法 样品均化与物理分析科 范围 PN-EN ISO 658:2004 | ISO 658:2002","technique_zh":"重量法","methodology_zh":"杂质含量","lab_section_zh":"样品均化与物理分析科","test_object_zh":"油料种子"},{"_id":"6a7d76396040ebab2620d4da","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Ryby i przetwory rybne oraz owoce morza","methodology":"Zawartość glazury","parameters":[{"name":"Zakres","range":"(5,0 – 45,0) % (m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość glazury\nZakres (5,0 – 45,0) % (m/m)\nMetoda wagowa","reference":"CODEX STAN 165-1989 (Rev. 1-1995) | PB-281 wyd. IV z dn. 11.01.2021","norm_bases":["CODEX STAN 165-1989 (Rev. 1-1995)","PB-281 wyd. IV z dn. 11.01.2021"],"lab_section":"Sekcja Uśredniania Próbek i Analiz Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ryby i przetwory rybne oraz owoce morza Zawartość glazury\nZakres (5,0 – 45,0) % (m/m)\nMetoda wagowa CODEX STAN 165-1989 (Rev. 1-1995) | PB-281 wyd. IV z dn. 11.01.2021 Ryby i przetwory rybne oraz owoce morza Zawartosc glazury\nZakres (5,0 – 45,0) % (m/m)\nMetoda wagowa CODEX STAN 165-1989 (Rev. 1-1995) | PB-281 wyd. IV z dn. 11.01.2021","categories":["other"],"row_index":611,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sample Homogenisation and Physical Analyses Section","methodology_en":"Glaze content","parameters_en":[{"name":"Range","range":"(5,0 – 45,0) % (m/m)"}],"search_en":"Fish and fish products and seafood Glaze content Gravimetric method Sample Homogenisation and Physical Analyses Section Range CODEX STAN 165-1989 (Rev. 1-1995) | PB-281 wyd. IV z dn. 11.01.2021","technique_en":"Gravimetric method","test_object_en":"Fish and fish products and seafood","parameters_zh":[{"name":"范围","range":"(5,0 – 45,0) % (m/m)"}],"search_zh":"鱼、鱼制品与海产品 冰衣含量 重量法 样品均化与物理分析科 范围 CODEX STAN 165-1989 (Rev. 1-1995) | PB-281 wyd. IV z dn. 11.01.2021","technique_zh":"重量法","lab_section_zh":"样品均化与物理分析科","methodology_zh":"冰衣含量","test_object_zh":"鱼、鱼制品与海产品"},{"_id":"6a7d76396040ebab2620d4db","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Zboża i przetwory zbożowe","methodology":"Ilość glutenu","parameters":[{"name":"Zakres","range":"(15 – 37) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Ilość glutenu\nZakres (15 – 37) %\nMetoda wagowa","reference":"PN-77/A-74041 p. 2.5.2.","norm_bases":["PN-77/A-74041 p. 2.5.2."],"lab_section":"Sekcja Uśredniania Próbek i Analiz Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zboża i przetwory zbożowe Ilość glutenu\nZakres (15 – 37) %\nMetoda wagowa PN-77/A-74041 p. 2.5.2. Zboza i przetwory zbozowe Ilosc glutenu\nZakres (15 – 37) %\nMetoda wagowa PN-77/A-74041 p. 2.5.2.","categories":["other"],"row_index":612,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sample Homogenisation and Physical Analyses Section","methodology_en":"Gluten quantity","parameters_en":[{"name":"Range","range":"(15 – 37) %"}],"search_en":"Cereals and cereal products Gluten quantity Gravimetric method Sample Homogenisation and Physical Analyses Section Range PN-77/A-74041 p. 2.5.2.","technique_en":"Gravimetric method","test_object_en":"Cereals and cereal products","parameters_zh":[{"name":"范围","range":"(15 – 37) %"}],"search_zh":"谷物与谷物制品 面筋含量 重量法 样品均化与物理分析科 范围 PN-77/A-74041 p. 2.5.2.","technique_zh":"重量法","test_object_zh":"谷物与谷物制品","lab_section_zh":"样品均化与物理分析科","methodology_zh":"面筋含量"},{"_id":"6a7d76396040ebab2620d4dc","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Zboża","methodology":"Gęstość ziarna w stanie zsypnym (masa hektolitra)","parameters":[{"name":"Zakres","range":"(35 – 90) kg/hl"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Gęstość ziarna w stanie zsypnym (masa hektolitra)\nZakres (35 – 90) kg/hl\nMetoda wagowa","reference":"PN-EN ISO 7971-3:2019-03","norm_bases":["PN-EN ISO 7971-3:2019-03"],"lab_section":"Sekcja Uśredniania Próbek i Analiz Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zboża Gęstość ziarna w stanie zsypnym (masa hektolitra)\nZakres (35 – 90) kg/hl\nMetoda wagowa PN-EN ISO 7971-3:2019-03 Zboza Gestosc ziarna w stanie zsypnym (masa hektolitra)\nZakres (35 – 90) kg/hl\nMetoda wagowa PN-EN ISO 7971-3:2019-03","categories":["other"],"row_index":613,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sample Homogenisation and Physical Analyses Section","methodology_en":"Bulk density of grain in the poured state (hectolitre mass)","parameters_en":[{"name":"Range","range":"(35 – 90) kg/hl"}],"search_en":"Cereals Bulk density of grain in the poured state (hectolitre mass) Gravimetric method Sample Homogenisation and Physical Analyses Section Range PN-EN ISO 7971-3:2019-03","technique_en":"Gravimetric method","test_object_en":"Cereals","parameters_zh":[{"name":"范围","range":"(35 – 90) kg/hl"}],"search_zh":"谷物 重量法 样品均化与物理分析科 范围 PN-EN ISO 7971-3:2019-03","technique_zh":"重量法","lab_section_zh":"样品均化与物理分析科","test_object_zh":"谷物"},{"_id":"6a7d76396040ebab2620d4dd","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Konserwy mięsne","methodology":"Szczelność","parameters":[],"technique":"Metoda próżniowa; Metoda wizualna","techniques":["Metoda próżniowa","Metoda wizualna"],"computed":[],"activity":"Szczelność\nMetoda próżniowa; Metoda wizualna","reference":"PN-A-82055-4:1997+Az1:2002","norm_bases":["PN-A-82055-4:1997+Az1:2002"],"lab_section":"Sekcja Uśredniania Próbek i Analiz Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Konserwy mięsne Szczelność\nMetoda próżniowa; Metoda wizualna PN-A-82055-4:1997+Az1:2002 Konserwy miesne Szczelnosc\nMetoda prozniowa; Metoda wizualna PN-A-82055-4:1997+Az1:2002","categories":["other"],"row_index":614,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sample Homogenisation and Physical Analyses Section","methodology_en":"Leak tightness","search_en":"Canned meat Leak tightness Vacuum method; Visual method Sample Homogenisation and Physical Analyses Section PN-A-82055-4:1997+Az1:2002","technique_en":"Vacuum method; Visual method","test_object_en":"Canned meat","methodology_zh":"密封性","search_zh":"肉类罐头 密封性 样品均化与物理分析科 PN-A-82055-4:1997+Az1:2002","lab_section_zh":"样品均化与物理分析科","test_object_zh":"肉类罐头"},{"_id":"6a7d76396040ebab2620d4de","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Konserwy mięsne","methodology":"Zawartość wytopionego tłuszczu i galarety","parameters":[{"name":"Zakres","range":"(1,0 – 25,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wytopionego tłuszczu i galarety\nZakres (1,0 – 25,0) %\nMetoda wagowa","reference":"PN-A-82056:1985 p. 2.3.8","norm_bases":["PN-A-82056:1985 p. 2.3.8"],"lab_section":"Sekcja Uśredniania Próbek i Analiz Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Konserwy mięsne Zawartość wytopionego tłuszczu i galarety\nZakres (1,0 – 25,0) %\nMetoda wagowa PN-A-82056:1985 p. 2.3.8 Konserwy miesne Zawartosc wytopionego tluszczu i galarety\nZakres (1,0 – 25,0) %\nMetoda wagowa PN-A-82056:1985 p. 2.3.8","categories":["other"],"row_index":615,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sample Homogenisation and Physical Analyses Section","methodology_en":"Content of rendered fat and jelly","parameters_en":[{"name":"Range","range":"(1,0 – 25,0) %"}],"search_en":"Canned meat Content of rendered fat and jelly Gravimetric method Sample Homogenisation and Physical Analyses Section Range PN-A-82056:1985 p. 2.3.8","technique_en":"Gravimetric method","test_object_en":"Canned meat","parameters_zh":[{"name":"范围","range":"(1,0 – 25,0) %"}],"search_zh":"肉类罐头 重量法 样品均化与物理分析科 范围 PN-A-82056:1985 p. 2.3.8","technique_zh":"重量法","lab_section_zh":"样品均化与物理分析科","test_object_zh":"肉类罐头"},{"_id":"6a7d76396040ebab2620d4df","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Konserwy warzywne, owocowe, warzywno-mięsne","methodology":"Szczelność","parameters":[],"technique":"Metoda próżniowa","techniques":["Metoda próżniowa"],"computed":[],"activity":"Szczelność\nMetoda próżniowa","reference":"PN-A-75052-02:1990","norm_bases":["PN-A-75052-02:1990"],"lab_section":"Sekcja Uśredniania Próbek i Analiz Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Konserwy warzywne, owocowe, warzywno-mięsne Szczelność\nMetoda próżniowa PN-A-75052-02:1990 Konserwy warzywne, owocowe, warzywno-miesne Szczelnosc\nMetoda prozniowa PN-A-75052-02:1990","categories":["other"],"row_index":616,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sample Homogenisation and Physical Analyses Section","methodology_en":"Leak tightness","search_en":"Canned vegetable, fruit and vegetable-meat products Leak tightness Vacuum method Sample Homogenisation and Physical Analyses Section PN-A-75052-02:1990","technique_en":"Vacuum method","test_object_en":"Canned vegetable, fruit and vegetable-meat products","methodology_zh":"密封性","search_zh":"密封性 真空法 样品均化与物理分析科 PN-A-75052-02:1990","technique_zh":"真空法","lab_section_zh":"样品均化与物理分析科"},{"_id":"6a7d76396040ebab2620d4e0","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Kawa i herbata, Koncentraty spożywcze, Mięso i produkty mięsne, Mleko i produkty mleczne, Owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, Ryby i przetwory rybne oraz owoce morza, Słodycze i wyroby cukiernicze, Surowce i przetwory zielarskie, przyprawy, Środki specjalnego przeznaczenia żywieniowego, Oleje, tłuszcze zwierzęce i roślinne, Zboża i przetwory zbożowe, Żywność mrożona, Wyroby garmażeryjne, Dodatki do żywności, Środki żywienia zwierząt","methodology":"Masa","parameters":[{"name":"Zakres","range":"(1,0 – 5000) g"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Masa\nZakres (1,0 – 5000) g\nMetoda wagowa","reference":"PB-281 wyd. IV z dn. 11.01.2021","norm_bases":["PB-281 wyd. IV z dn. 11.01.2021"],"lab_section":"Sekcja Uśredniania Próbek i Analiz Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kawa i herbata, Koncentraty spożywcze, Mięso i produkty mięsne, Mleko i produkty mleczne, Owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, Ryby i przetwory rybne oraz owoce morza, Słodycze i wyroby cukiernicze, Surowce i przetwory zielarskie, przyprawy, Środki specjalnego przeznaczenia żywieniowego, Oleje, tłuszcze zwierzęce i roślinne, Zboża i przetwory zbożowe, Żywność mrożona, Wyroby garmażeryjne, Dodatki do żywności, Środki żywienia zwierząt Masa\nZakres (1,0 – 5000) g\nMetoda wagowa PB-281 wyd. IV z dn. 11.01.2021 Kawa i herbata, Koncentraty spozywcze, Mieso i produkty miesne, Mleko i produkty mleczne, Owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-miesne, Ryby i przetwory rybne oraz owoce morza, Slodycze i wyroby cukiernicze, Surowce i przetwory zielarskie, przyprawy, Srodki specjalnego przeznaczenia zywieniowego, Oleje, tluszcze zwierzece i roslinne, Zboza i przetwory zbozowe, Zywnosc mrozona, Wyroby garmazeryjne, Dodatki do zywnosci, Srodki zywienia zwierzat Masa\nZakres (1,0 – 5000) g\nMetoda wagowa PB-281 wyd. IV z dn. 11.01.2021","categories":["food","petro"],"row_index":617,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sample Homogenisation and Physical Analyses Section","methodology_en":"Mass","parameters_en":[{"name":"Range","range":"(1,0 – 5000) g"}],"search_en":"Coffee and tea, Food concentrates, Meat and meat products, Milk and dairy products, Fruit and vegetables and fruit and vegetable products and vegetable-meat products, Fish and fish products and seafood, Sweets and confectionery, Herbal raw materials and products, spices, Foodstuffs for particular nutritional uses, Oils, animal and vegetable fats, Cereals and cereal products, Frozen food, Delicatessen products, Food additives, Animal feed Mass Gravimetric method Sample Homogenisation and Physical Analyses Section Range PB-281 wyd. IV z dn. 11.01.2021","technique_en":"Gravimetric method","test_object_en":"Coffee and tea, Food concentrates, Meat and meat products, Milk and dairy products, Fruit and vegetables and fruit and vegetable products and vegetable-meat products, Fish and fish products and seafood, Sweets and confectionery, Herbal raw materials and products, spices, Foodstuffs for particular nutritional uses, Oils, animal and vegetable fats, Cereals and cereal products, Frozen food, Delicatessen products, Food additives, Animal feed","parameters_zh":[{"name":"范围","range":"(1,0 – 5000) g"}],"search_zh":"质量 重量法 样品均化与物理分析科 范围 PB-281 wyd. IV z dn. 11.01.2021","technique_zh":"重量法","methodology_zh":"质量","lab_section_zh":"样品均化与物理分析科"},{"_id":"6a7d76396040ebab2620d4e1","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Suplementy diety","methodology":"Masa","parameters":[{"name":"Zakres","range":"(0,15 – 100) g"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Masa\nZakres (0,15 – 100) g\nMetoda wagowa","reference":"PB-281 wyd. IV z dn. 11.01.2021","norm_bases":["PB-281 wyd. IV z dn. 11.01.2021"],"lab_section":"Sekcja Uśredniania Próbek i Analiz Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Suplementy diety Masa\nZakres (0,15 – 100) g\nMetoda wagowa PB-281 wyd. IV z dn. 11.01.2021 Suplementy diety Masa\nZakres (0,15 – 100) g\nMetoda wagowa PB-281 wyd. IV z dn. 11.01.2021","categories":["pharma"],"row_index":618,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sample Homogenisation and Physical Analyses Section","methodology_en":"Mass","parameters_en":[{"name":"Range","range":"(0,15 – 100) g"}],"search_en":"Food supplements Mass Gravimetric method Sample Homogenisation and Physical Analyses Section Range PB-281 wyd. IV z dn. 11.01.2021","technique_en":"Gravimetric method","test_object_en":"Food supplements","parameters_zh":[{"name":"范围","range":"(0,15 – 100) g"}],"search_zh":"膳食补充剂 质量 重量法 样品均化与物理分析科 范围 PB-281 wyd. IV z dn. 11.01.2021","technique_zh":"重量法","test_object_zh":"膳食补充剂","methodology_zh":"质量","lab_section_zh":"样品均化与物理分析科"},{"_id":"6a7d76396040ebab2620d4e2","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Konserwy mięsne","methodology":"Masa","parameters":[{"name":"Zakres","range":"(50,0 – 5000) g"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Masa\nZakres (50,0 – 5000) g\nMetoda wagowa","reference":"PN-A-82056:1985 p. 2.3.5","norm_bases":["PN-A-82056:1985 p. 2.3.5"],"lab_section":"Sekcja Uśredniania Próbek i Analiz Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Konserwy mięsne Masa\nZakres (50,0 – 5000) g\nMetoda wagowa PN-A-82056:1985 p. 2.3.5 Konserwy miesne Masa\nZakres (50,0 – 5000) g\nMetoda wagowa PN-A-82056:1985 p. 2.3.5","categories":["other"],"row_index":619,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sample Homogenisation and Physical Analyses Section","methodology_en":"Mass","parameters_en":[{"name":"Range","range":"(50,0 – 5000) g"}],"search_en":"Canned meat Mass Gravimetric method Sample Homogenisation and Physical Analyses Section Range PN-A-82056:1985 p. 2.3.5","technique_en":"Gravimetric method","test_object_en":"Canned meat","parameters_zh":[{"name":"范围","range":"(50,0 – 5000) g"}],"search_zh":"肉类罐头 质量 重量法 样品均化与物理分析科 范围 PN-A-82056:1985 p. 2.3.5","technique_zh":"重量法","methodology_zh":"质量","lab_section_zh":"样品均化与物理分析科","test_object_zh":"肉类罐头"},{"_id":"6a7d76396040ebab2620d4e3","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Owoce i warzywa i przetwory, owocowe i warzywne oraz warzywno-mięsne","methodology":"Masa","parameters":[{"name":"Zakres","range":"(50,0 – 5000) g"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Masa\nZakres (50,0 – 5000) g\nMetoda wagowa","reference":"PN-A-75101-15:1990 p. 2","norm_bases":["PN-A-75101-15:1990 p. 2"],"lab_section":"Sekcja Uśredniania Próbek i Analiz Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Owoce i warzywa i przetwory, owocowe i warzywne oraz warzywno-mięsne Masa\nZakres (50,0 – 5000) g\nMetoda wagowa PN-A-75101-15:1990 p. 2 Owoce i warzywa i przetwory, owocowe i warzywne oraz warzywno-miesne Masa\nZakres (50,0 – 5000) g\nMetoda wagowa PN-A-75101-15:1990 p. 2","categories":["other"],"row_index":620,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sample Homogenisation and Physical Analyses Section","methodology_en":"Mass","parameters_en":[{"name":"Range","range":"(50,0 – 5000) g"}],"search_en":"Fruit and vegetables and fruit, vegetable and vegetable-meat products Mass Gravimetric method Sample Homogenisation and Physical Analyses Section Range PN-A-75101-15:1990 p. 2","technique_en":"Gravimetric method","test_object_en":"Fruit and vegetables and fruit, vegetable and vegetable-meat products","parameters_zh":[{"name":"范围","range":"(50,0 – 5000) g"}],"search_zh":"质量 重量法 样品均化与物理分析科 范围 PN-A-75101-15:1990 p. 2","technique_zh":"重量法","methodology_zh":"质量","lab_section_zh":"样品均化与物理分析科"},{"_id":"6a7d76396040ebab2620d4e4","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Mleko i przetwory mleczne, Napoje alkoholowe, Napoje bezalkoholowe, Płynne koncentraty spożywcze, Płynne suplementy diety, Soki owocowe i warzywne, nektary","methodology":"Pomiar objętości","parameters":[{"name":"Zakres","range":"(50 – 2000) ml"}],"technique":"Metoda objętościowa","techniques":["Metoda objętościowa"],"computed":[],"activity":"Pomiar objętości\nZakres (50 – 2000) ml\nMetoda objętościowa","reference":"PB-369 wyd. I z dn. 04.01.2018","norm_bases":["PB-369 wyd. I z dn. 04.01.2018"],"lab_section":"Sekcja Uśredniania Próbek i Analiz Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko i przetwory mleczne, Napoje alkoholowe, Napoje bezalkoholowe, Płynne koncentraty spożywcze, Płynne suplementy diety, Soki owocowe i warzywne, nektary Pomiar objętości\nZakres (50 – 2000) ml\nMetoda objętościowa PB-369 wyd. I z dn. 04.01.2018 Mleko i przetwory mleczne, Napoje alkoholowe, Napoje bezalkoholowe, Plynne koncentraty spozywcze, Plynne suplementy diety, Soki owocowe i warzywne, nektary Pomiar objetosci\nZakres (50 – 2000) ml\nMetoda objetosciowa PB-369 wyd. I z dn. 04.01.2018","categories":["food","pharma"],"row_index":621,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sample Homogenisation and Physical Analyses Section","methodology_en":"Volume measurement","parameters_en":[{"name":"Range","range":"(50 – 2000) ml"}],"search_en":"Milk and milk products, Alcoholic beverages, Non-alcoholic beverages, Liquid food concentrates, Liquid food supplements, Fruit and vegetable juices, nectars Volume measurement Volumetric method Sample Homogenisation and Physical Analyses Section Range PB-369 wyd. I z dn. 04.01.2018","technique_en":"Volumetric method","test_object_en":"Milk and milk products, Alcoholic beverages, Non-alcoholic beverages, Liquid food concentrates, Liquid food supplements, Fruit and vegetable juices, nectars","parameters_zh":[{"name":"范围","range":"(50 – 2000) ml"}],"search_zh":"体积测量 容量法 样品均化与物理分析科 范围 PB-369 wyd. I z dn. 04.01.2018","technique_zh":"容量法","lab_section_zh":"样品均化与物理分析科","methodology_zh":"体积测量"},{"_id":"6a7d76396040ebab2620d4e5","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Mleko i przetwory mleczne, Napoje alkoholowe, Napoje bezalkoholowe, Płynne koncentraty spożywcze, Płynne suplementy diety, Soki owocowe i warzywne, nektary","methodology":"Pomiar objętości","parameters":[{"name":"Zakres","range":"(50 – 5000) ml"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Pomiar objętości\nZakres (50 – 5000) ml\nMetoda wagowa","reference":"PB-369 wyd. I z dn. 04.01.2018","norm_bases":["PB-369 wyd. I z dn. 04.01.2018"],"lab_section":"Sekcja Uśredniania Próbek i Analiz Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko i przetwory mleczne, Napoje alkoholowe, Napoje bezalkoholowe, Płynne koncentraty spożywcze, Płynne suplementy diety, Soki owocowe i warzywne, nektary Pomiar objętości\nZakres (50 – 5000) ml\nMetoda wagowa PB-369 wyd. I z dn. 04.01.2018 Mleko i przetwory mleczne, Napoje alkoholowe, Napoje bezalkoholowe, Plynne koncentraty spozywcze, Plynne suplementy diety, Soki owocowe i warzywne, nektary Pomiar objetosci\nZakres (50 – 5000) ml\nMetoda wagowa PB-369 wyd. I z dn. 04.01.2018","categories":["food","pharma"],"row_index":622,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sample Homogenisation and Physical Analyses Section","methodology_en":"Volume measurement","parameters_en":[{"name":"Range","range":"(50 – 5000) ml"}],"search_en":"Milk and milk products, Alcoholic beverages, Non-alcoholic beverages, Liquid food concentrates, Liquid food supplements, Fruit and vegetable juices, nectars Volume measurement Gravimetric method Sample Homogenisation and Physical Analyses Section Range PB-369 wyd. I z dn. 04.01.2018","technique_en":"Gravimetric method","test_object_en":"Milk and milk products, Alcoholic beverages, Non-alcoholic beverages, Liquid food concentrates, Liquid food supplements, Fruit and vegetable juices, nectars","parameters_zh":[{"name":"范围","range":"(50 – 5000) ml"}],"search_zh":"体积测量 重量法 样品均化与物理分析科 范围 PB-369 wyd. I z dn. 04.01.2018","technique_zh":"重量法","lab_section_zh":"样品均化与物理分析科","methodology_zh":"体积测量"},{"_id":"6a7d76396040ebab2620d4e6","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Napoje bezalkoholowe, Piwo","methodology":"Stężenie ditlenku węgla","parameters":[{"name":"Zakres","range":"(2,9 – 8,0) g/l"}],"technique":"Metoda ciśnieniowa","techniques":["Metoda ciśnieniowa"],"computed":[],"activity":"Stężenie ditlenku węgla\nZakres (2,9 – 8,0) g/l\nMetoda ciśnieniowa","reference":"PB-491 wyd. 1 z dn. 29.12.2021","norm_bases":["PB-491 wyd. 1 z dn. 29.12.2021"],"lab_section":"Sekcja Uśredniania Próbek i Analiz Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Napoje bezalkoholowe, Piwo Stężenie ditlenku węgla\nZakres (2,9 – 8,0) g/l\nMetoda ciśnieniowa PB-491 wyd. 1 z dn. 29.12.2021 Woda do spozycia przez ludzi, Napoje bezalkoholowe, Piwo Stezenie ditlenku wegla\nZakres (2,9 – 8,0) g/l\nMetoda cisnieniowa PB-491 wyd. 1 z dn. 29.12.2021","categories":["water","food"],"row_index":623,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Sample Homogenisation and Physical Analyses Section","methodology_en":"Carbon dioxide concentration","parameters_en":[{"name":"Range","range":"(2,9 – 8,0) g/l"}],"search_en":"Water intended for human consumption, Non-alcoholic beverages, Beer Carbon dioxide concentration Pressure method Sample Homogenisation and Physical Analyses Section Range PB-491 wyd. 1 z dn. 29.12.2021","technique_en":"Pressure method","test_object_en":"Water intended for human consumption, Non-alcoholic beverages, Beer","parameters_zh":[{"name":"范围","range":"(2,9 – 8,0) g/l"}],"search_zh":"二氧化碳浓度 压力法 样品均化与物理分析科 范围 PB-491 wyd. 1 z dn. 29.12.2021","technique_zh":"压力法","lab_section_zh":"样品均化与物理分析科","methodology_zh":"二氧化碳浓度"},{"_id":"6a7d76396040ebab2620d4e7","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Produkty kosmetyczne, produkty chemii gospodarczej przeznaczonej do kontaktu ze skórą, artykuły higieniczne","methodology":"Obecność alergicznego odczynu/wyprysku kontaktowego","parameters":[],"technique":"Metoda drażnienia skóry in vivo – test otwarty","techniques":["Metoda drażnienia skóry in vivo – test otwarty"],"computed":[],"activity":"Obecność alergicznego odczynu/wyprysku kontaktowego\nMetoda drażnienia skóry in vivo – test otwarty","reference":"PB-562 wyd. 4 z dn. 07.03.2025","norm_bases":["PB-562 wyd. 4 z dn. 07.03.2025"],"lab_section":"Sekcja Dermatologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Produkty kosmetyczne, produkty chemii gospodarczej przeznaczonej do kontaktu ze skórą, artykuły higieniczne Obecność alergicznego odczynu/wyprysku kontaktowego\nMetoda drażnienia skóry in vivo – test otwarty PB-562 wyd. 4 z dn. 07.03.2025 Produkty kosmetyczne, produkty chemii gospodarczej przeznaczonej do kontaktu ze skora, artykuly higieniczne Obecnosc alergicznego odczynu/wyprysku kontaktowego\nMetoda draznienia skory in vivo – test otwarty PB-562 wyd. 4 z dn. 07.03.2025","categories":["other"],"row_index":624,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Dermatology Section","methodology_en":"Presence of allergic reaction/contact eczema","search_en":"Cosmetic products, household chemical products intended for skin contact, hygiene articles Presence of allergic reaction/contact eczema In vivo skin irritation method – open test Dermatology Section PB-562 wyd. 4 z dn. 07.03.2025","technique_en":"In vivo skin irritation method – open test","test_object_en":"Cosmetic products, household chemical products intended for skin contact, hygiene articles"},{"_id":"6a7d76396040ebab2620d4e8","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Produkty kosmetyczne, produkty chemii gospodarczej przeznaczonej do kontaktu ze skórą, artykuły higieniczne","methodology":"Obecność alergicznego odczynu/wyprysku kontaktowego","parameters":[],"technique":"Metoda drażnienia skóry in vivo – test półotwarty i zamknięty","techniques":["Metoda drażnienia skóry in vivo – test półotwarty i zamknięty"],"computed":[],"activity":"Obecność alergicznego odczynu/wyprysku kontaktowego\nMetoda drażnienia skóry in vivo – test półotwarty i zamknięty","reference":"PB-561 wyd. 4 z dn. 07.03.2025","norm_bases":["PB-561 wyd. 4 z dn. 07.03.2025"],"lab_section":"Sekcja Dermatologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Produkty kosmetyczne, produkty chemii gospodarczej przeznaczonej do kontaktu ze skórą, artykuły higieniczne Obecność alergicznego odczynu/wyprysku kontaktowego\nMetoda drażnienia skóry in vivo – test półotwarty i zamknięty PB-561 wyd. 4 z dn. 07.03.2025 Produkty kosmetyczne, produkty chemii gospodarczej przeznaczonej do kontaktu ze skora, artykuly higieniczne Obecnosc alergicznego odczynu/wyprysku kontaktowego\nMetoda draznienia skory in vivo – test polotwarty i zamkniety PB-561 wyd. 4 z dn. 07.03.2025","categories":["other"],"row_index":625,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Dermatology Section","methodology_en":"Presence of allergic reaction/contact eczema","search_en":"Cosmetic products, household chemical products intended for skin contact, hygiene articles Presence of allergic reaction/contact eczema In vivo skin irritation method – semi-occlusive and occlusive test Dermatology Section PB-561 wyd. 4 z dn. 07.03.2025","technique_en":"In vivo skin irritation method – semi-occlusive and occlusive test","test_object_en":"Cosmetic products, household chemical products intended for skin contact, hygiene articles"},{"_id":"6a7d76396040ebab2620d4e9","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Nasiona oleiste","methodology":"Zawartość wody i substancji lotnych","parameters":[{"name":"Zakres","range":"(3,0 – 12,0)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wody i substancji lotnych\nZakres (3,0 – 12,0)%\nMetoda wagowa","reference":"PN-EN ISO 665:2020-09","norm_bases":["PN-EN ISO 665:2020-09"],"lab_section":"Pracownia Analiz Pozostałości Pestycydów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nasiona oleiste Zawartość wody i substancji lotnych\nZakres (3,0 – 12,0)%\nMetoda wagowa PN-EN ISO 665:2020-09 Nasiona oleiste Zawartosc wody i substancji lotnych\nZakres (3,0 – 12,0)%\nMetoda wagowa PN-EN ISO 665:2020-09","categories":["water"],"row_index":626,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Pesticide Residues Analysis Laboratory","methodology_en":"Water and volatile matter content","parameters_en":[{"name":"Range","range":"(3,0 – 12,0)%"}],"search_en":"Oilseeds Water and volatile matter content Gravimetric method Pesticide Residues Analysis Laboratory Range PN-EN ISO 665:2020-09","technique_en":"Gravimetric method","test_object_en":"Oilseeds","methodology_zh":"水分与挥发物含量","parameters_zh":[{"name":"范围","range":"(3,0 – 12,0)%"}],"search_zh":"油料种子 水分与挥发物含量 重量法 农药残留分析检验室 范围 PN-EN ISO 665:2020-09","technique_zh":"重量法","test_object_zh":"油料种子","lab_section_zh":"农药残留分析检验室"},{"_id":"6a7d76396040ebab2620d4ea","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Części roślin E, Podłoża uprawowe E, Produkty rolne E, RE)","methodology":"Zawartość pozostałości pestycydów","parameters":[],"technique":"Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS); Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","techniques":["Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)"],"computed":[],"activity":"Zawartość pozostałości pestycydów\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS); Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","reference":"Normy EURL-SRM QuPPe-Method Procedury badawcze","norm_bases":["Normy EURL-SRM QuPPe-Method Procedury badawcze"],"lab_section":"Pracownia Analiz Pozostałości Pestycydów","lab_address":null,"regulatory_area":"RE) - Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów rozporządzenia (UE) nr 625/2017 Parlamentu Europejskiego i Rady z dnia 15 marca 2017 r. w sprawie kontroli urzędowych i innych czynności urzędowych przeprowadzanych w celu zapewnienia stosowania prawa żywnościowego i paszowego oraz zasad dotyczących zdrowia i dobrostanu zwierząt, zdrowia roślin i środków ochrony roślin (Dz. U. UE L 95/1 z 07.04.2017, z późn. zm.), rozporządzenia Parlamentu Europejskiego i Rady (UE) 2018/848 z dnia 30 maja 2018 roku w sprawie produkcji ekologicznej i znakowania produktów ekologicznych i uchylającego rozporządzenie Rady (WE) 834/2007 oraz dokumentu SANTE/11312/2021 v2. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Części roślin E, Podłoża uprawowe E, Produkty rolne E, RE) Zawartość pozostałości pestycydów\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS); Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS) Normy EURL-SRM QuPPe-Method Procedury badawcze Zywnosc E, Czesci roslin E, Podloza uprawowe E, Produkty rolne E, RE) Zawartosc pozostalosci pestycydow\nMetoda chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS-MS); Metoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC-MS-MS) Normy EURL-SRM QuPPe-Method Procedury badawcze","categories":["food"],"row_index":627,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Pesticide Residues Analysis Laboratory","methodology_en":"Pesticide residue content","regulatory_area_en":"RE) - The competence of the laboratory has been confirmed taking into account the applicable requirements of Regulation (EU) No 625/2017 of the European Parliament and of the Council of 15 March 2017 on official controls and other official activities performed to ensure the application of food and feed law, rules on animal health and welfare, plant health and plant protection products (Dz. U. UE L 95/1 z 07.04.2017, z późn. zm.), Regulation (EU) 2018/848 of the European Parliament and of the Council of 30 May 2018 on organic production and labelling of organic products and repealing Council Regulation (EC) 834/2007 and document SANTE/11312/2021 v2. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Plant parts E, Growing media E, Agricultural products E, RE) Pesticide residue content Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS); Gas chromatography with tandem mass spectrometry detection (GC-MS-MS) Pesticide Residues Analysis Laboratory RE) - The competence of the laboratory has been confirmed taking into account the applicable requirements of Regulation (EU) No 625/2017 of the European Parliament and of the Council of 15 March 2017 on official controls and other official activities performed to ensure the application of food and feed law, rules on animal health and welfare, plant health and plant protection products (Dz. U. UE L 95/1 z 07.04.2017, z późn. zm.), Regulation (EU) 2018/848 of the European Parliament and of the Council of 30 May 2018 on organic production and labelling of organic products and repealing Council Regulation (EC) 834/2007 and document SANTE/11312/2021 v2. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy EURL-SRM QuPPe-Method Procedury badawcze","technique_en":"Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS); Gas chromatography with tandem mass spectrometry detection (GC-MS-MS)","test_object_en":"Food E, Plant parts E, Growing media E, Agricultural products E, RE)","methodology_zh":"农药残留含量","search_zh":"农药残留含量 农药残留分析检验室 Normy EURL-SRM QuPPe-Method Procedury badawcze","lab_section_zh":"农药残留分析检验室"},{"_id":"6a7d76396040ebab2620d4eb","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Gleba E","methodology":"Zawartość pozostałości pestycydów","parameters":[],"technique":"Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS); Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","techniques":["Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)"],"computed":[],"activity":"Zawartość pozostałości pestycydów\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS); Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Analiz Pozostałości Pestycydów","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Gleba E Zawartość pozostałości pestycydów\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS); Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS) Normy Gleba E Zawartosc pozostalosci pestycydow\nMetoda chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS-MS); Metoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC-MS-MS) Normy","categories":["environment"],"row_index":628,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Pesticide Residues Analysis Laboratory","methodology_en":"Pesticide residue content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Soil E Pesticide residue content Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS); Gas chromatography with tandem mass spectrometry detection (GC-MS-MS) Pesticide Residues Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy","technique_en":"Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS); Gas chromatography with tandem mass spectrometry detection (GC-MS-MS)","test_object_en":"Soil E","methodology_zh":"农药残留含量","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"土壤 E 农药残留含量 农药残留分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy","test_object_zh":"土壤 E","lab_section_zh":"农药残留分析检验室"},{"_id":"6a7d76396040ebab2620d4ec","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność pochodzenia roślinnego E, Produkty rolne E, RE), Części roślin E","methodology":"Zawartość pozostałości ditiokarbaminianów","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS); Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją spektrometrią mas (HS-GC-MS)"],"computed":[],"activity":"Zawartość pozostałości ditiokarbaminianów\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS); Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją spektrometrią mas (HS-GC-MS)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Pozostałości Pestycydów","lab_address":null,"regulatory_area":"RE) - Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów rozporządzenia (UE) nr 625/2017 Parlamentu Europejskiego i Rady z dnia 15 marca 2017 r. w sprawie kontroli urzędowych i innych czynności urzędowych przeprowadzanych w celu zapewnienia stosowania prawa żywnościowego i paszowego oraz zasad dotyczących zdrowia i dobrostanu zwierząt, zdrowia roślin i środków ochrony roślin (Dz. U. UE L 95/1 z 07.04.2017, z późn. zm.), rozporządzenia Parlamentu Europejskiego i Rady (UE) 2018/848 z dnia 30 maja 2018 roku w sprawie produkcji ekologicznej i znakowania produktów ekologicznych i uchylającego rozporządzenie Rady (WE) 834/2007 oraz dokumentu SANTE/11312/2021 v2. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność pochodzenia roślinnego E, Produkty rolne E, RE), Części roślin E Zawartość pozostałości ditiokarbaminianów\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS); Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją spektrometrią mas (HS-GC-MS) Procedury badawcze Zywnosc pochodzenia roslinnego E, Produkty rolne E, RE), Czesci roslin E Zawartosc pozostalosci ditiokarbaminianow\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS); Metoda chromatografii gazowej z analiza fazy nadpowierzchniowej z detekcja spektrometria mas (HS-GC-MS) Procedury badawcze","categories":["food"],"row_index":629,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Pesticide Residues Analysis Laboratory","methodology_en":"Content of dithiocarbamate residues","regulatory_area_en":"RE) - The competence of the laboratory has been confirmed taking into account the applicable requirements of Regulation (EU) No 625/2017 of the European Parliament and of the Council of 15 March 2017 on official controls and other official activities performed to ensure the application of food and feed law, rules on animal health and welfare, plant health and plant protection products (Dz. U. UE L 95/1 z 07.04.2017, z późn. zm.), Regulation (EU) 2018/848 of the European Parliament and of the Council of 30 May 2018 on organic production and labelling of organic products and repealing Council Regulation (EC) 834/2007 and document SANTE/11312/2021 v2. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food of plant origin E, Agricultural products E, RE), Plant parts E Content of dithiocarbamate residues Gas chromatography with mass spectrometry detection (GC-MS); Gas chromatography with headspace analysis with mass spectrometry detection (HS-GC-MS) Pesticide Residues Analysis Laboratory RE) - The competence of the laboratory has been confirmed taking into account the applicable requirements of Regulation (EU) No 625/2017 of the European Parliament and of the Council of 15 March 2017 on official controls and other official activities performed to ensure the application of food and feed law, rules on animal health and welfare, plant health and plant protection products (Dz. U. UE L 95/1 z 07.04.2017, z późn. zm.), Regulation (EU) 2018/848 of the European Parliament and of the Council of 30 May 2018 on organic production and labelling of organic products and repealing Council Regulation (EC) 834/2007 and document SANTE/11312/2021 v2. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Procedury badawcze","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS); Gas chromatography with headspace analysis with mass spectrometry detection (HS-GC-MS)","test_object_en":"Food of plant origin E, Agricultural products E, RE), Plant parts E","lab_section_zh":"农药残留分析检验室","search_zh":"农药残留分析检验室 Procedury badawcze"},{"_id":"6a7d76396040ebab2620d4ed","lab_id":"69ad52a3de79e566650fb107","country":"PL","accr_number":"AB 079","accr_body":"PCA","test_object":"Żywność E, Produkty rolne E","methodology":"Zawartość metali","parameters":[],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Zawartość metali\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Pracownia Analiz Pozostałości Pestycydów","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Produkty rolne E Zawartość metali\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) Normy Procedury badawcze Zywnosc E, Produkty rolne E Zawartosc metali\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) Normy Procedury badawcze","categories":["materials","food"],"row_index":630,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Pesticide Residues Analysis Laboratory","methodology_en":"Metal content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body.","search_en":"Food E, Agricultural products E Metal content Inductively coupled plasma mass spectrometry (ICP-MS) Pesticide Residues Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made available on request by the accredited body. Normy Procedury badawcze","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Food E, Agricultural products E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。","search_zh":"食品 E、农产品 E 金属含量 电感耦合等离子体质谱法（ICP-MS） 农药残留分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构应要求提供。 Normy Procedury badawcze","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","methodology_zh":"金属含量","test_object_zh":"食品 E、农产品 E","lab_section_zh":"农药残留分析检验室"}],"has_pdf":true}