{"lab":{"_id":"69ad52a3de79e566650fb101","accr_number":"AB 075","country":"PL","accr_body":"PCA","address":"ul. Chmielna 132/134, 00-805 Warszawa, CENTRALNE LABORATORIUM BADAWCZE, ODDZIAŁ WE WROCŁAWIU","categories":["water","environment","materials"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":110,"name":"GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_075.pdf"],"scope_summary":"","search_text":"główny inspektorat ochrony środowiska ul. chmielna 132/134, 00-805 warszawa, centralne laboratorium badawcze, oddział we wrocławiu water other environment microbiology pharma electronics metrology food materials","status":"active","updated_at":"2026-03-08T14:50:08.572Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:08.572Z","parse_date":"2026-07-17T16:19:10.781Z","parse_source":"m5-mistral-qa","email_confidence":"high","email_mx":true,"email_source":"https://www.gov.pl/web/gios/centralne-laboratorium-badawcze","fields_of_testing":[{"codes":"C/28/P, C/30/P, C/31/P, C/32/P","pl":"Badania chemiczne i pobieranie próbek wody, ścieków, gleby, osadów, odpadów","en":"Chemical tests and sampling of water, sewage, soil, sediments, waste"},{"codes":"C/36/P","pl":"Badania chemiczne gazów odlotowych","en":"Chemical tests of waste gases"},{"codes":"G/34, G/36","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne - hałas, pole elektromagnetyczne), gazy odlotowe","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors – noise, electromagnetic field), waste gases"},{"codes":"N/28/P, N/30/P, N/31/P, N/32/P, N/36/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, ścieków, gleby, osadów, odpadów, gazów odlotowych","en":"Tests of physical properties and sampling of water, sewage, soil, sediments, waste, waste gases"},{"codes":"P/32","pl":"Pobieranie próbek osadów ściekowych do badań mikrobiologicznych i biologicznych","en":"Sampling of sediments microbiological and biological tests"}],"issue":{"no":"29","date":"13.01.2026"},"map_coord":[52.227738,20.992749],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":73,"environment":33,"other":7,"materials":5,"petro":2,"microbiology":1},"category_scores":{"water":44.04,"environment":9,"other":0.4,"materials":0.21,"petro":0.03,"microbiology":0.01},"has_zh":true},"methods":[{"_id":"6a5a55fe9af9f73f38253683","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda powierzchniowa","test_object_en":"Surface water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody i pobranej próbki wody Zakres: (0,0 – 50,0) 0C","methodology_en":"Sampling for chemical and physical testing Temperature of water and of the water sample taken Range: (0,0 – 50,0) 0C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody i pobranej próbki wody Zakres: (0,0 – 50,0) 0C","reference":"PN-EN ISO 5667-6:2016-12 PN-77/C-04584","norm_bases":["PN-EN ISO 5667-6:2016-12 PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda powierzchniowa Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody i pobranej próbki wody Zakres: (0,0 – 50,0) 0C PN-EN ISO 5667-6:2016-12 PN-77/C-04584 Woda powierzchniowa Pobieranie probek do badan chemicznych i fizycznych Temperatura wody i pobranej probki wody Zakres: (0,0 – 50,0) 0C PN-EN ISO 5667-6:2016-12 PN-77/C-04584","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Surface water Sampling for chemical and physical testing Temperature of water and of the water sample taken Range: (0,0 – 50,0) 0C PN-EN ISO 5667-6:2016-12 PN-77/C-04584","search_zh":"地表水 PN-EN ISO 5667-6:2016-12 PN-77/C-04584","test_object_zh":"地表水"},{"_id":"6a5a55fe9af9f73f38253684","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna i automatyczna Temperatura ścieku i pobranej próbki ścieku Zakres: (0,0 – 50,0) 0C","methodology_en":"Sampling for chemical and physical testing Manual and automatic method Temperature of wastewater and of the wastewater sample taken Range: (0,0 – 50,0) 0C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna i automatyczna Temperatura ścieku i pobranej próbki ścieku Zakres: (0,0 – 50,0) 0C","reference":"PN-ISO 5667-10:2021-11 PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11 PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna i automatyczna Temperatura ścieku i pobranej próbki ścieku Zakres: (0,0 – 50,0) 0C PN-ISO 5667-10:2021-11 PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych Metoda manualna i automatyczna Temperatura scieku i pobranej probki scieku Zakres: (0,0 – 50,0) 0C PN-ISO 5667-10:2021-11 PN-77/C-04584","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Sampling for chemical and physical testing Manual and automatic method Temperature of wastewater and of the wastewater sample taken Range: (0,0 – 50,0) 0C PN-ISO 5667-10:2021-11 PN-77/C-04584","search_zh":"污水 PN-ISO 5667-10:2021-11 PN-77/C-04584","test_object_zh":"污水"},{"_id":"6a5a55fe9af9f73f38253685","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Wody opadowe Wody roztopowe","test_object_en":"Rainwater Snowmelt water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna","methodology_en":"Sampling for chemical and physical testing Manual method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wody opadowe Wody roztopowe Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna PN-ISO 5667-10:2021-11 Wody opadowe Wody roztopowe Pobieranie probek do badan chemicznych i fizycznych Metoda manualna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rainwater Snowmelt water Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11","methodology_zh":"用于化学与物理检验的采样 手工法","search_zh":"雨水 融雪水 用于化学与物理检验的采样 手工法 PN-ISO 5667-10:2021-11","test_object_zh":"雨水 融雪水"},{"_id":"6a5a55fe9af9f73f38253686","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda podziemna","test_object_en":"Groundwater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (0,0 – 50,0) 0C","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample taken Range: (0,0 – 50,0) 0C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (0,0 – 50,0) 0C","reference":"PN-EN ISO 5667-11:2017-10 z wyłączeniem p. 5.2 | PN-77/C-04584","norm_bases":["PN-EN ISO 5667-11:2017-10 z wyłączeniem p. 5.2","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda podziemna Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (0,0 – 50,0) 0C PN-EN ISO 5667-11:2017-10 z wyłączeniem p. 5.2 | PN-77/C-04584 Woda podziemna Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody Zakres: (0,0 – 50,0) 0C PN-EN ISO 5667-11:2017-10 z wylaczeniem p. 5.2 | PN-77/C-04584","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Groundwater Sampling for chemical and physical testing Temperature of the water sample taken Range: (0,0 – 50,0) 0C PN-EN ISO 5667-11:2017-10 z wyłączeniem p. 5.2 | PN-77/C-04584","search_zh":"地下水 PN-EN ISO 5667-11:2017-10 z wyłączeniem p. 5.2 | PN-77/C-04584","test_object_zh":"地下水"},{"_id":"6a5a55fe9af9f73f38253687","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"ISO 10381-4:2007 PN ISO 10381-5:2009","norm_bases":["ISO 10381-4:2007 PN ISO 10381-5:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Pobieranie próbek do badań chemicznych i fizycznych ISO 10381-4:2007 PN ISO 10381-5:2009 Gleba Pobieranie probek do badan chemicznych i fizycznych ISO 10381-4:2007 PN ISO 10381-5:2009","categories":["environment"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Sampling for chemical and physical testing ISO 10381-4:2007 PN ISO 10381-5:2009","methodology_zh":"化学与物理检测用样品采集","search_zh":"土壤 化学与物理检测用样品采集 ISO 10381-4:2007 PN ISO 10381-5:2009","test_object_zh":"土壤"},{"_id":"6a5a55fe9af9f73f38253688","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Osady ściekowe OdpadyO: kod 19 08 05","test_object_en":"Sewage sludge WasteO: code 19 08 05","methodology":"Pobieranie próbek do badań chemicznych, fizycznych, mikrobiologicznych i parazytologicznych","methodology_en":"Sampling for chemical, physical, microbiological and parasitological testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych, mikrobiologicznych i parazytologicznych","reference":"PN-EN ISO 5667-13:2011","norm_bases":["PN-EN ISO 5667-13:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe OdpadyO: kod 19 08 05 Pobieranie próbek do badań chemicznych, fizycznych, mikrobiologicznych i parazytologicznych PN-EN ISO 5667-13:2011 Osady sciekowe OdpadyO: kod 19 08 05 Pobieranie probek do badan chemicznych, fizycznych, mikrobiologicznych i parazytologicznych PN-EN ISO 5667-13:2011","categories":["water","environment","microbiology"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge WasteO: code 19 08 05 Sampling for chemical, physical, microbiological and parasitological testing PN-EN ISO 5667-13:2011","methodology_zh":"用于化学、物理、微生物与寄生虫学检验的采样","search_zh":"用于化学、物理、微生物与寄生虫学检验的采样 PN-EN ISO 5667-13:2011"},{"_id":"6a5a55fe9af9f73f38253689","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"pH Zakres: (2,0 – 12,0) Metoda potencjometryczna","methodology_en":"pH Range: (2,0 – 12,0) Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: (2,0 – 12,0) Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki pH Zakres: (2,0 – 12,0) Metoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki pH Zakres: (2,0 – 12,0) Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater pH Range: (2,0 – 12,0) Potentiometric method PN-EN ISO 10523:2012","search_zh":"水、废水 pH 范围：(2,0 – 12,0) 电位法 PN-EN ISO 10523:2012","test_object_zh":"水、废水","methodology_zh":"pH 范围：(2,0 – 12,0) 电位法"},{"_id":"6a5a55fe9af9f73f3825368a","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Przewodność elektryczna właściwa Zakres: (10 – 20000) μS/cm Metoda konduktometryczna","methodology_en":"Electrical conductivity Range: (10 – 20000) μS/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (10 – 20000) μS/cm Metoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Przewodność elektryczna właściwa Zakres: (10 – 20000) μS/cm Metoda konduktometryczna PN-EN 27888:1999 Woda, scieki Przewodnosc elektryczna wlasciwa Zakres: (10 – 20000) μS/cm Metoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Electrical conductivity Range: (10 – 20000) μS/cm Conductometric method PN-EN 27888:1999","search_zh":"水、废水 PN-EN 27888:1999","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f3825368b","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie tlenu rozpuszczonego Zakres: (0,3 – 20,0) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Dissolved oxygen concentration Range: (0,3 – 20,0) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenu rozpuszczonego Zakres: (0,3 – 20,0) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN ISO 5814:2013-04","norm_bases":["PN-EN ISO 5814:2013-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie tlenu rozpuszczonego Zakres: (0,3 – 20,0) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5814:2013-04 Woda, scieki Stezenie tlenu rozpuszczonego Zakres: (0,3 – 20,0) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5814:2013-04","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Dissolved oxygen concentration Range: (0,3 – 20,0) mg/l O 2 Electrochemical method PN-EN ISO 5814:2013-04","search_zh":"水、废水 PN-EN ISO 5814:2013-04","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f3825368c","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A Zakres: (25 – 135) dB Metoda pomiarowa: bezpośrednia","methodology_en":"A-weighted equivalent sound level Range: (25 – 135) dB Measurement method: direct","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Zakres: (25 – 135) dB Metoda pomiarowa: bezpośrednia","reference":"Nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 | eniem punktu F","norm_bases":["Nr 7","enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023","eniem punktu F"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A Zakres: (25 – 135) dB Metoda pomiarowa: bezpośrednia Nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 | eniem punktu F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A Zakres: (25 – 135) dB Metoda pomiarowa: bezposrednia Nr 7 | enia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 | eniem punktu F","categories":["environment"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound level Range: (25 – 135) dB Measurement method: direct Nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 | eniem punktu F","search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 Nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 | eniem punktu F","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"},{"_id":"6a5a55fe9af9f73f3825368d","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami L i L AeqD AeqN (z obliczeń)","methodology_en":"A-weighted equivalent sound level for reference time T expressed as L and L AeqD AeqN indices (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami L i L AeqD AeqN (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami L i L AeqD AeqN (z obliczeń) Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami L i L AeqD AeqN (z obliczen)","categories":["environment"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound level for reference time T expressed as L and L AeqD AeqN indices (calculated)","search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 参考时间 T 的 A 计权等效声级，以 L 与 L AeqD AeqN 指标表示（计算值）","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声","methodology_zh":"参考时间 T 的 A 计权等效声级，以 L 与 L AeqD AeqN 指标表示（计算值）"},{"_id":"6a5a55fe9af9f73f3825368e","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","test_object_en":"General environment – noise from roads, railway lines, tram lines","methodology":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A Zakres: (25 – 135) dB Metoda pomiarowa: bezpośrednia","methodology_en":"A-weighted equivalent sound level A-weighted sound exposure level Range: (25 – 135) dB Measurement method: direct","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A Zakres: (25 – 135) dB Metoda pomiarowa: bezpośrednia","reference":"nr 3 | enia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140 | eniem punktu H (Dz. U. 2011 nr 288","norm_bases":["nr 3","enia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140","eniem punktu H (Dz. U. 2011 nr 288"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A Zakres: (25 – 135) dB Metoda pomiarowa: bezpośrednia nr 3 | enia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140 | eniem punktu H (Dz. U. 2011 nr 288 Srodowisko ogolne – halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A Ekspozycyjny poziom dzwieku A Zakres: (25 – 135) dB Metoda pomiarowa: bezposrednia nr 3 | enia Ministra Srodowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140 | eniem punktu H (Dz. U. 2011 nr 288","categories":["environment"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment – noise from roads, railway lines, tram lines A-weighted equivalent sound level A-weighted sound exposure level Range: (25 – 135) dB Measurement method: direct nr 3 | enia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140 | eniem punktu H (Dz. U. 2011 nr 288","search_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声 nr 3 | enia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140 | eniem punktu H (Dz. U. 2011 nr 288","test_object_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声"},{"_id":"6a5a55fe9af9f73f3825368f","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","test_object_en":"General environment – noise from roads, railway lines, tram lines","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami L i L AeqD AeqN (z obliczeń)","methodology_en":"A-weighted equivalent sound level for reference time T expressed as L and L AeqD AeqN indices (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami L i L AeqD AeqN (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami L i L AeqD AeqN (z obliczeń) Srodowisko ogolne – halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami L i L AeqD AeqN (z obliczen)","categories":["environment"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment – noise from roads, railway lines, tram lines A-weighted equivalent sound level for reference time T expressed as L and L AeqD AeqN indices (calculated)","search_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声 参考时间 T 的 A 计权等效声级，以 L 与 L AeqD AeqN 指标表示（计算值）","test_object_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声","methodology_zh":"参考时间 T 的 A 计权等效声级，以 L 与 L AeqD AeqN 指标表示（计算值）"},{"_id":"6a5a55fe9af9f73f38253690","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Środowisko ogólne – hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment – impulse noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Ekspozycyjny poziom dźwięku A Zakres: (25 – 135) dB Metoda pomiarowa bezpośrednia","methodology_en":"A-weighted equivalent sound level A-weighted maximum sound level A-weighted sound exposure level Range: (25 – 135) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Ekspozycyjny poziom dźwięku A Zakres: (25 – 135) dB Metoda pomiarowa bezpośrednia","reference":"Nr 8 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023","norm_bases":["Nr 8","enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Ekspozycyjny poziom dźwięku A Zakres: (25 – 135) dB Metoda pomiarowa bezpośrednia Nr 8 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 Srodowisko ogolne – halas impulsowy pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A Ekspozycyjny poziom dzwieku A Zakres: (25 – 135) dB Metoda pomiarowa bezposrednia Nr 8 | enia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023","categories":["environment"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment – impulse noise from installations, equipment and industrial plants A-weighted equivalent sound level A-weighted maximum sound level A-weighted sound exposure level Range: (25 – 135) dB Direct measurement method Nr 8 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023","search_zh":"一般环境 － 来自装置、设备与工业企业的脉冲噪声 Nr 8 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023","test_object_zh":"一般环境 － 来自装置、设备与工业企业的脉冲噪声"},{"_id":"6a5a55fe9af9f73f38253691","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Środowisko ogólne – hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment – impulse noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami L i L AeqD AeqN (z obliczeń)","methodology_en":"A-weighted equivalent sound level for reference time T expressed as L and L AeqD AeqN indices (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami L i L AeqD AeqN (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami L i L AeqD AeqN (z obliczeń) Srodowisko ogolne – halas impulsowy pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami L i L AeqD AeqN (z obliczen)","categories":["environment"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment – impulse noise from installations, equipment and industrial plants A-weighted equivalent sound level for reference time T expressed as L and L AeqD AeqN indices (calculated)","methodology_zh":"参考时间 T 的 A 计权等效声级，以 L 与 L AeqD AeqN 指标表示（计算值）","search_zh":"一般环境 － 来自装置、设备与工业企业的脉冲噪声 参考时间 T 的 A 计权等效声级，以 L 与 L AeqD AeqN 指标表示（计算值）","test_object_zh":"一般环境 － 来自装置、设备与工业企业的脉冲噪声"},{"_id":"6a5a55fe9af9f73f38253692","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Odpady","test_object_en":"Waste","methodology":"Badania interwencyjne (wg Programu DAB-11)","methodology_en":"Intervention testing (according to Programme DAB-11)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania interwencyjne (wg Programu DAB-11)","reference":"PB-11/CLB wydanie 1 z dnia 25.09.2023 r.","norm_bases":["PB-11/CLB wydanie 1 z dnia 25.09.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady Badania interwencyjne (wg Programu DAB-11) PB-11/CLB wydanie 1 z dnia 25.09.2023 r. Odpady Badania interwencyjne (wg Programu DAB-11) PB-11/CLB wydanie 1 z dnia 25.09.2023 r.","categories":["environment"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste Intervention testing (according to Programme DAB-11) PB-11/CLB wydanie 1 z dnia 25.09.2023 r.","search_zh":"废物 干预性检验（依据 DAB-11 计划） PB-11/CLB wydanie 1 z dnia 25.09.2023 r.","test_object_zh":"废物","methodology_zh":"干预性检验（依据 DAB-11 计划）"},{"_id":"6a5a55fe9af9f73f38253693","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"OdpadyO): kod 10 09 10, 19 01 12","test_object_en":"WasteO): code 10 09 10, 19 01 12","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PB-05/WR wydanie 1 z dnia 01.04.2021 r.","norm_bases":["PB-05/WR wydanie 1 z dnia 01.04.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"OdpadyO): kod 10 09 10, 19 01 12 Pobieranie próbek do badań chemicznych i fizycznych PB-05/WR wydanie 1 z dnia 01.04.2021 r. OdpadyO): kod 10 09 10, 19 01 12 Pobieranie probek do badan chemicznych i fizycznych PB-05/WR wydanie 1 z dnia 01.04.2021 r.","categories":["environment"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"WasteO): code 10 09 10, 19 01 12 Sampling for chemical and physical testing PB-05/WR wydanie 1 z dnia 01.04.2021 r.","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 PB-05/WR wydanie 1 z dnia 01.04.2021 r."},{"_id":"6a5a55fe9af9f73f38253694","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","test_object_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines","methodology":"Natężenie pola elektrycznego o częstotliwości 50 Hz Zakres: (100 – 50000) V/m Metoda pomiarowa bezpośrednia","methodology_en":"Electric field strength at a frequency of 50 Hz Range: (100 – 50000) V/m Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego o częstotliwości 50 Hz Zakres: (100 – 50000) V/m Metoda pomiarowa bezpośrednia","reference":"enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natężenie pola elektrycznego o częstotliwości 50 Hz Zakres: (100 – 50000) V/m Metoda pomiarowa bezpośrednia enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natezenie pola elektrycznego o czestotliwosci 50 Hz Zakres: (100 – 50000) V/m Metoda pomiarowa bezposrednia enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines Electric field strength at a frequency of 50 Hz Range: (100 – 50000) V/m Direct measurement method enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","search_zh":"环境 — 变电站与输电线路周围的电磁场 enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","test_object_zh":"环境 — 变电站与输电线路周围的电磁场"},{"_id":"6a5a55fe9af9f73f38253695","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","test_object_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines","methodology":"Indukcja magnetyczna o częstotliwości 50 Hz Zakres: 0,1 µT – 10 mT Metoda pomiarowa bezpośrednia","methodology_en":"Magnetic flux density at a frequency of 50 Hz Range: 0,1 µT – 10 mT Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indukcja magnetyczna o częstotliwości 50 Hz Zakres: 0,1 µT – 10 mT Metoda pomiarowa bezpośrednia","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Indukcja magnetyczna o częstotliwości 50 Hz Zakres: 0,1 µT – 10 mT Metoda pomiarowa bezpośrednia Srodowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Indukcja magnetyczna o czestotliwosci 50 Hz Zakres: 0,1 µT – 10 mT Metoda pomiarowa bezposrednia","categories":["environment"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic flux density at a frequency of 50 Hz Range: 0,1 µT – 10 mT Direct measurement method","search_zh":"环境 — 变电站与输电线路周围的电磁场","test_object_zh":"环境 — 变电站与输电线路周围的电磁场"},{"_id":"6a5a55fe9af9f73f38253696","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","test_object_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines","methodology":"Natężenie pola magnetycznego o częstotliwości 50 Hz (z obliczeń)","methodology_en":"Magnetic field strength at 50 Hz frequency (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego o częstotliwości 50 Hz (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natężenie pola magnetycznego o częstotliwości 50 Hz (z obliczeń) Srodowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natezenie pola magnetycznego o czestotliwosci 50 Hz (z obliczen)","categories":["environment"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic field strength at 50 Hz frequency (calculated)","search_zh":"环境 — 变电站与输电线路周围的电磁场 50 Hz 工频磁场强度（由计算得出）","test_object_zh":"环境 — 变电站与输电线路周围的电磁场","methodology_zh":"50 Hz 工频磁场强度（由计算得出）"},{"_id":"6a5a55fe9af9f73f38253697","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe)","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements)","methodology":"Natężenie pola elektrycznego: w zakresie częstotliwości od 80 MHz do 60 GHz Zakres: (0,3 – 300) V/m Metoda pomiarowa bezpośrednia","methodology_en":"Electric field strength: in the frequency range from 80 MHz to 60 GHz Range: (0,3 – 300) V/m Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego: w zakresie częstotliwości od 80 MHz do 60 GHz Zakres: (0,3 – 300) V/m Metoda pomiarowa bezpośrednia","reference":"enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natężenie pola elektrycznego: w zakresie częstotliwości od 80 MHz do 60 GHz Zakres: (0,3 – 300) V/m Metoda pomiarowa bezpośrednia enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natezenie pola elektrycznego: w zakresie czestotliwosci od 80 MHz do 60 GHz Zakres: (0,3 – 300) V/m Metoda pomiarowa bezposrednia enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Electric field strength: in the frequency range from 80 MHz to 60 GHz Range: (0,3 – 300) V/m Direct measurement method enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","search_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量） enia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","test_object_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量）"},{"_id":"6a5a55fe9af9f73f38253698","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe)","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements)","methodology":"Natężenie pola magnetycznego: w zakresie częstotliwości","methodology_en":"Magnetic field strength: in the frequency range","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego: w zakresie częstotliwości","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natężenie pola magnetycznego: w zakresie częstotliwości Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natezenie pola magnetycznego: w zakresie czestotliwosci","categories":["environment"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength: in the frequency range","search_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量）","test_object_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量）"},{"_id":"6a5a55fe9af9f73f38253699","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe)","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements)","methodology":"od 80 MHz do 60 GHz","methodology_en":"from 80 MHz to 60 GHz","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"od 80 MHz do 60 GHz","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) od 80 MHz do 60 GHz Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) od 80 MHz do 60 GHz","categories":["environment"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) from 80 MHz to 60 GHz","search_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量）","test_object_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量）"},{"_id":"6a5a55fe9af9f73f3825369a","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe)","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements)","methodology":"(z obliczeń)","methodology_en":"(calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"(z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) (z obliczeń) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) (z obliczen)","categories":["environment"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) (calculated)","methodology_zh":"（计算得出）","search_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量） （计算得出）","test_object_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量）"},{"_id":"6a5a55fe9af9f73f3825369b","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie dwutlenku siarki, tlenków azotu, tlenku węgla, dwutlenku węgla i tlenu Zakres: SO (5,0 – 2860) mg/m3 2 CO (7,0 – 2500) mg/m3 CO (0,2 – 18,0) % 2 Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) NO (2,0 – 925) mg/m3 x Metoda chemiluminescencyjna O (0,2 – 21,0) % 2 Metoda paramagnetyczna","methodology_en":"Concentration of sulphur dioxide, nitrogen oxides, carbon monoxide, carbon dioxide and oxygen Range: SO (5,0 – 2860) mg/m3 2 CO (7,0 – 2500) mg/m3 CO (0,2 – 18,0) % 2 Non-dispersive infrared spectrometry method (NDIR) NO (2,0 – 925) mg/m3 x Chemiluminescence method O (0,2 – 21,0) % 2 Paramagnetic method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie dwutlenku siarki, tlenków azotu, tlenku węgla, dwutlenku węgla i tlenu Zakres: SO (5,0 – 2860) mg/m3 2 CO (7,0 – 2500) mg/m3 CO (0,2 – 18,0) % 2 Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) NO (2,0 – 925) mg/m3 x Metoda chemiluminescencyjna O (0,2 – 21,0) % 2 Metoda paramagnetyczna","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie dwutlenku siarki, tlenków azotu, tlenku węgla, dwutlenku węgla i tlenu Zakres: SO (5,0 – 2860) mg/m3 2 CO (7,0 – 2500) mg/m3 CO (0,2 – 18,0) % 2 Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) NO (2,0 – 925) mg/m3 x Metoda chemiluminescencyjna O (0,2 – 21,0) % 2 Metoda paramagnetyczna PN-ISO 10396:2001 Gazy odlotowe Stezenie dwutlenku siarki, tlenkow azotu, tlenku wegla, dwutlenku wegla i tlenu Zakres: SO (5,0 – 2860) mg/m3 2 CO (7,0 – 2500) mg/m3 CO (0,2 – 18,0) % 2 Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) NO (2,0 – 925) mg/m3 x Metoda chemiluminescencyjna O (0,2 – 21,0) % 2 Metoda paramagnetyczna PN-ISO 10396:2001","categories":["other"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Concentration of sulphur dioxide, nitrogen oxides, carbon monoxide, carbon dioxide and oxygen Range: SO (5,0 – 2860) mg/m3 2 CO (7,0 – 2500) mg/m3 CO (0,2 – 18,0) % 2 Non-dispersive infrared spectrometry method (NDIR) NO (2,0 – 925) mg/m3 x Chemiluminescence method O (0,2 – 21,0) % 2 Paramagnetic method PN-ISO 10396:2001","search_zh":"废气 PN-ISO 10396:2001","test_object_zh":"废气"},{"_id":"6a5a55fe9af9f73f3825369c","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja SO , NO (NO 2 x i NO w przeliczeniu na NO ), CO, 2 2 CO 2 (z obliczeń)","methodology_en":"Emission of SO , NO (NO 2 x and NO calculated as NO ), CO, 2 2 CO 2 (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja SO , NO (NO 2 x i NO w przeliczeniu na NO ), CO, 2 2 CO 2 (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja SO , NO (NO 2 x i NO w przeliczeniu na NO ), CO, 2 2 CO 2 (z obliczeń) Gazy odlotowe Emisja SO , NO (NO 2 x i NO w przeliczeniu na NO ), CO, 2 2 CO 2 (z obliczen)","categories":["environment"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of SO , NO (NO 2 x and NO calculated as NO ), CO, 2 2 CO 2 (calculated)","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a55fe9af9f73f3825369d","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","methodology_en":"Sampling for determination of dust concentration","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-Z-04030-7:1994 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-Z-04030-7:1994","categories":["other"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of dust concentration PN-Z-04030-7:1994","search_zh":"废气 粉尘浓度测定采样 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样"},{"_id":"6a5a55fe9af9f73f3825369e","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pyłu Zakres: (0,001 – 10,0) g/m3 Metoda grawimetryczna","methodology_en":"Dust concentration Range: (0,001 – 10,0) g/m3 Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pyłu Zakres: (0,001 – 10,0) g/m3 Metoda grawimetryczna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pyłu Zakres: (0,001 – 10,0) g/m3 Metoda grawimetryczna Gazy odlotowe Stezenie pylu Zakres: (0,001 – 10,0) g/m3 Metoda grawimetryczna","categories":["other"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Dust concentration Range: (0,001 – 10,0) g/m3 Gravimetric method","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a55fe9af9f73f3825369f","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja pyłu (z obliczeń)","methodology_en":"Dust emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja pyłu (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) Gazy odlotowe Emisja pylu (z obliczen)","categories":["environment"],"row_index":28,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Dust emission (calculated)","search_zh":"废气 粉尘排放量（计算值）","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a5a55fe9af9f73f382536a0","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa Metoda spiętrzenia Prędkość Zakres: (1,0 – 10,0) m/s Metoda termoanemometryczna","methodology_en":"Gas volume flow rate for dynamic pressures > 10 Pa Pitot tube method Velocity Range: (1,0 – 10,0) m/s Thermoanemometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa Metoda spiętrzenia Prędkość Zakres: (1,0 – 10,0) m/s Metoda termoanemometryczna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa Metoda spiętrzenia Prędkość Zakres: (1,0 – 10,0) m/s Metoda termoanemometryczna Gazy odlotowe Strumien objetosci gazu dla cisnien dynamicznych > 10 Pa Metoda spietrzenia Predkosc Zakres: (1,0 – 10,0) m/s Metoda termoanemometryczna","categories":["other"],"row_index":29,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Gas volume flow rate for dynamic pressures > 10 Pa Pitot tube method Velocity Range: (1,0 – 10,0) m/s Thermoanemometric method","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a55fe9af9f73f382536a1","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych","methodology_en":"Sampling for determination of the concentration of individual gaseous organic compounds","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych PN-EN 13649:2005 Gazy odlotowe Pobieranie probek do oznaczania stezenia indywidualnych gazowych zwiazkow organicznych PN-EN 13649:2005","categories":["other"],"row_index":30,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of the concentration of individual gaseous organic compounds PN-EN 13649:2005","search_zh":"废气 单项气态有机化合物浓度测定采样 PN-EN 13649:2005","test_object_zh":"废气","methodology_zh":"单项气态有机化合物浓度测定采样"},{"_id":"6a5a55fe9af9f73f382536a2","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","methodology_en":"Emission of individual gaseous organic compounds (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja indywidualnych gazowych związków organicznych (z obliczeń) Gazy odlotowe Emisja indywidualnych gazowych zwiazkow organicznych (z obliczen)","categories":["environment"],"row_index":31,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of individual gaseous organic compounds (calculated)","search_zh":"废气 单项气态有机化合物排放量（计算值）","test_object_zh":"废气","methodology_zh":"单项气态有机化合物排放量（计算值）"},{"_id":"6a5a55fe9af9f73f382536a3","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężeń związków organicznych Metoda aspiracyjna z zastosowaniem węgla aktywnego/ żelu krzemionkowego","methodology_en":"Sampling for determination of the concentrations of organic compounds Aspiration method using activated carbon/ silica gel","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężeń związków organicznych Metoda aspiracyjna z zastosowaniem węgla aktywnego/ żelu krzemionkowego","reference":"PN-Z-04008-4:1999","norm_bases":["PN-Z-04008-4:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężeń związków organicznych Metoda aspiracyjna z zastosowaniem węgla aktywnego/ żelu krzemionkowego PN-Z-04008-4:1999 Gazy odlotowe Pobieranie probek do oznaczania stezen zwiazkow organicznych Metoda aspiracyjna z zastosowaniem wegla aktywnego/ zelu krzemionkowego PN-Z-04008-4:1999","categories":["other"],"row_index":32,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of the concentrations of organic compounds Aspiration method using activated carbon/ silica gel PN-Z-04008-4:1999","search_zh":"废气 PN-Z-04008-4:1999","test_object_zh":"废气"},{"_id":"6a5a55fe9af9f73f382536a4","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja związków organicznych (z obliczeń)","methodology_en":"Emission of organic compounds (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja związków organicznych (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja związków organicznych (z obliczeń) Gazy odlotowe Emisja zwiazkow organicznych (z obliczen)","categories":["environment"],"row_index":33,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of organic compounds (calculated)","search_zh":"废气 有机化合物排放量（计算值）","test_object_zh":"废气","methodology_zh":"有机化合物排放量（计算值）"},{"_id":"6a5a55fe9af9f73f382536a5","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny Zakres: (2,0 – 1000) mg/m3 Metoda ciągłej detekcji płomieniowo- jonizacyjnej (FID)","methodology_en":"Concentration of organic substances in gaseous and vapour form expressed as total gaseous organic carbon Range: (2,0 – 1000) mg/m3 Continuous flame ionisation detection method (FID)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny Zakres: (2,0 – 1000) mg/m3 Metoda ciągłej detekcji płomieniowo- jonizacyjnej (FID)","reference":"PN-EN 12619:2013-05","norm_bases":["PN-EN 12619:2013-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny Zakres: (2,0 – 1000) mg/m3 Metoda ciągłej detekcji płomieniowo- jonizacyjnej (FID) PN-EN 12619:2013-05 Gazy odlotowe Stezenie substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny Zakres: (2,0 – 1000) mg/m3 Metoda ciaglej detekcji plomieniowo- jonizacyjnej (FID) PN-EN 12619:2013-05","categories":["other"],"row_index":34,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Concentration of organic substances in gaseous and vapour form expressed as total gaseous organic carbon Range: (2,0 – 1000) mg/m3 Continuous flame ionisation detection method (FID) PN-EN 12619:2013-05","search_zh":"废气 PN-EN 12619:2013-05","test_object_zh":"废气"},{"_id":"6a5a55fe9af9f73f382536a6","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń)","methodology_en":"Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń) Gazy odlotowe Emisja substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny (z obliczen)","categories":["environment"],"row_index":35,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated)","search_zh":"废气 以总气态有机碳表示的气态与蒸气态有机物排放量（计算值）","test_object_zh":"废气","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物排放量（计算值）"},{"_id":"6a5a55fe9af9f73f382536a7","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Całkowite substancje rozpuszczone (TDS) Zakres: (20 – 10000) mg/l Metoda wagowa","methodology_en":"Total dissolved solids (TDS) Range: (20 – 10000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Całkowite substancje rozpuszczone (TDS) Zakres: (20 – 10000) mg/l Metoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Całkowite substancje rozpuszczone (TDS) Zakres: (20 – 10000) mg/l Metoda wagowa PN-EN 15216:2022-03 Woda, scieki Calkowite substancje rozpuszczone (TDS) Zakres: (20 – 10000) mg/l Metoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":36,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Total dissolved solids (TDS) Range: (20 – 10000) mg/l Gravimetric method PN-EN 15216:2022-03","search_zh":"水、废水 PN-EN 15216:2022-03","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536a8","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Zawiesiny ogólne Zakres: (5,0 – 6000) mg/l Metoda wagowa","methodology_en":"Total suspended solids (TSS) Range: (5,0 – 6000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: (5,0 – 6000) mg/l Metoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Zawiesiny ogólne Zakres: (5,0 – 6000) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne Zakres: (5,0 – 6000) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":37,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Total suspended solids (TSS) Range: (5,0 – 6000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007","search_zh":"水、废水 总悬浮物 范围：(5,0 – 6000) mg/l 重量法 PN-EN 872:2007+Ap1:2007","test_object_zh":"水、废水","methodology_zh":"总悬浮物 范围：(5,0 – 6000) mg/l 重量法"},{"_id":"6a5a55fe9af9f73f382536a9","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie tlenu rozpuszczonego Zakres: (0,3 – 20,0) mg/l O 2 Metoda miareczkowa","methodology_en":"Dissolved oxygen concentration Range: (0,3 – 20,0) mg/l O 2 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenu rozpuszczonego Zakres: (0,3 – 20,0) mg/l O 2 Metoda miareczkowa","reference":"PN-EN 25813:1997","norm_bases":["PN-EN 25813:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie tlenu rozpuszczonego Zakres: (0,3 – 20,0) mg/l O 2 Metoda miareczkowa PN-EN 25813:1997 Woda, scieki Stezenie tlenu rozpuszczonego Zakres: (0,3 – 20,0) mg/l O 2 Metoda miareczkowa PN-EN 25813:1997","categories":["water"],"row_index":38,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Dissolved oxygen concentration Range: (0,3 – 20,0) mg/l O 2 Titrimetric method PN-EN 25813:1997","search_zh":"水、废水 PN-EN 25813:1997","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536aa","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT , BZT 5 2+5 Zakres: (1,0 – 6,0) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD , BOD 5 2+5 Range: (1,0 – 6,0) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT , BZT 5 2+5 Zakres: (1,0 – 6,0) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT , BZT 5 2+5 Zakres: (1,0 – 6,0) mg/l O 2 Metoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT , BZT 5 2+5 Zakres: (1,0 – 6,0) mg/l O 2 Metoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":39,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Biochemical oxygen demand - BOD , BOD 5 2+5 Range: (1,0 – 6,0) mg/l O 2 Electrochemical method PN-EN 1899-2:2002","search_zh":"水、废水 PN-EN 1899-2:2002","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536ab","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT , BZT 5 2+5 Zakres: (5,0 – 6000) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD , BOD 5 2+5 Range: (5,0 – 6000) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT , BZT 5 2+5 Zakres: (5,0 – 6000) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT , BZT 5 2+5 Zakres: (5,0 – 6000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT , BZT 5 2+5 Zakres: (5,0 – 6000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":40,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Biochemical oxygen demand - BOD , BOD 5 2+5 Range: (5,0 – 6000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12","search_zh":"水、废水 PN-EN ISO 5815-1:2019-12","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536ac","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (5,0 – 9000) mg/l O 2 Metoda spektrofotometryczna","methodology_en":"Chemical oxygen demand - COD-Cr Range: (5,0 – 9000) mg/l O 2 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (5,0 – 9000) mg/l O 2 Metoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (5,0 – 9000) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (5,0 – 9000) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":41,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Chemical oxygen demand - COD-Cr Range: (5,0 – 9000) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005","search_zh":"水、废水 PN-ISO 15705:2005","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536ad","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie anionów Zakres: - chlorki (1,00 – 1000) mg/l - siarczany (1,0 – 1000) mg/l - azot azotanowy (0,113 – 50) mg/l - azotany (0,50 – 221) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","methodology_en":"Anion concentrations Range: - chlorides (1,00 – 1000) mg/l - sulfates (1,0 – 1000) mg/l - nitrate nitrogen (0,113 – 50) mg/l - nitrates (0,50 – 221) mg/l Ion chromatography with conductometric detection (IC-CD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie anionów Zakres: - chlorki (1,00 – 1000) mg/l - siarczany (1,0 – 1000) mg/l - azot azotanowy (0,113 – 50) mg/l - azotany (0,50 – 221) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie anionów Zakres: - chlorki (1,00 – 1000) mg/l - siarczany (1,0 – 1000) mg/l - azot azotanowy (0,113 – 50) mg/l - azotany (0,50 – 221) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, scieki Stezenie anionow Zakres: - chlorki (1,00 – 1000) mg/l - siarczany (1,0 – 1000) mg/l - azot azotanowy (0,113 – 50) mg/l - azotany (0,50 – 221) mg/l Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":42,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Anion concentrations Range: - chlorides (1,00 – 1000) mg/l - sulfates (1,0 – 1000) mg/l - nitrate nitrogen (0,113 – 50) mg/l - nitrates (0,50 – 221) mg/l Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","search_zh":"水、废水 PN-EN ISO 10304-1:2009+AC:2012","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536ae","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu amonowego Zakres: (0,050 – 250) mg/l N-NH 4 (0,064 – 322) mg/l NH 4 Metoda analizy przepływowej (CFA) z detekcją spektrometryczną","methodology_en":"Ammonium nitrogen concentration Range: (0,050 – 250) mg/l N-NH 4 (0,064 – 322) mg/l NH 4 Flow analysis (CFA) with spectrometric detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego Zakres: (0,050 – 250) mg/l N-NH 4 (0,064 – 322) mg/l NH 4 Metoda analizy przepływowej (CFA) z detekcją spektrometryczną","reference":"PN-EN ISO 11732:2007","norm_bases":["PN-EN ISO 11732:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu amonowego Zakres: (0,050 – 250) mg/l N-NH 4 (0,064 – 322) mg/l NH 4 Metoda analizy przepływowej (CFA) z detekcją spektrometryczną PN-EN ISO 11732:2007 Woda, scieki Stezenie azotu amonowego Zakres: (0,050 – 250) mg/l N-NH 4 (0,064 – 322) mg/l NH 4 Metoda analizy przeplywowej (CFA) z detekcja spektrometryczna PN-EN ISO 11732:2007","categories":["water"],"row_index":43,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Ammonium nitrogen concentration Range: (0,050 – 250) mg/l N-NH 4 (0,064 – 322) mg/l NH 4 Flow analysis (CFA) with spectrometric detection PN-EN ISO 11732:2007","search_zh":"水、废水 PN-EN ISO 11732:2007","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536af","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie kationów Zakres: - sodowy (1,0 – 1000) mg/l - potasowy (0,50 – 1000) mg/l - magnezowy (0,50 – 1000) mg/l - wapniowy (1,0 – 1000) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","methodology_en":"Cation concentration Range: - sodium (1,0 – 1000) mg/l - potassium (0,50 – 1000) mg/l - magnesium (0,50 – 1000) mg/l - calcium (1,0 – 1000) mg/l Ion chromatography with conductometric detection (IC-CD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie kationów Zakres: - sodowy (1,0 – 1000) mg/l - potasowy (0,50 – 1000) mg/l - magnezowy (0,50 – 1000) mg/l - wapniowy (1,0 – 1000) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 14911:2002","norm_bases":["PN-EN ISO 14911:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie kationów Zakres: - sodowy (1,0 – 1000) mg/l - potasowy (0,50 – 1000) mg/l - magnezowy (0,50 – 1000) mg/l - wapniowy (1,0 – 1000) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 14911:2002 Woda, scieki Stezenie kationow Zakres: - sodowy (1,0 – 1000) mg/l - potasowy (0,50 – 1000) mg/l - magnezowy (0,50 – 1000) mg/l - wapniowy (1,0 – 1000) mg/l Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 14911:2002","categories":["water"],"row_index":44,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Cation concentration Range: - sodium (1,0 – 1000) mg/l - potassium (0,50 – 1000) mg/l - magnesium (0,50 – 1000) mg/l - calcium (1,0 – 1000) mg/l Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 14911:2002","search_zh":"水、废水 PN-EN ISO 14911:2002","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536b0","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Twardość ogólna (z obliczeń)","methodology_en":"Total hardness (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Twardość ogólna (z obliczeń)","reference":"PB-03/WR wydanie 1 z dnia 01.06.2021 r.","norm_bases":["PB-03/WR wydanie 1 z dnia 01.06.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Twardość ogólna (z obliczeń) PB-03/WR wydanie 1 z dnia 01.06.2021 r. Woda, scieki Twardosc ogolna (z obliczen) PB-03/WR wydanie 1 z dnia 01.06.2021 r.","categories":["water"],"row_index":45,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Total hardness (calculated) PB-03/WR wydanie 1 z dnia 01.06.2021 r.","search_zh":"水、废水 总硬度（由计算得出） PB-03/WR wydanie 1 z dnia 01.06.2021 r.","test_object_zh":"水、废水","methodology_zh":"总硬度（由计算得出）"},{"_id":"6a5a55fe9af9f73f382536b1","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu azotynowego Zakres: (0,005 – 5,00) mg/l N-NO 2 (0,016 – 16,4) mg/l NO 2 Metoda analizy przepływowej (CFA) z detekcją spektrometryczną","methodology_en":"Nitrite nitrogen concentration Range: (0,005 – 5,00) mg/l N-NO 2 (0,016 – 16,4) mg/l NO 2 Flow analysis (CFA) with spectrometric detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego Zakres: (0,005 – 5,00) mg/l N-NO 2 (0,016 – 16,4) mg/l NO 2 Metoda analizy przepływowej (CFA) z detekcją spektrometryczną","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu azotynowego Zakres: (0,005 – 5,00) mg/l N-NO 2 (0,016 – 16,4) mg/l NO 2 Metoda analizy przepływowej (CFA) z detekcją spektrometryczną PN-EN ISO 13395:2001 Woda, scieki Stezenie azotu azotynowego Zakres: (0,005 – 5,00) mg/l N-NO 2 (0,016 – 16,4) mg/l NO 2 Metoda analizy przeplywowej (CFA) z detekcja spektrometryczna PN-EN ISO 13395:2001","categories":["water"],"row_index":46,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Nitrite nitrogen concentration Range: (0,005 – 5,00) mg/l N-NO 2 (0,016 – 16,4) mg/l NO 2 Flow analysis (CFA) with spectrometric detection PN-EN ISO 13395:2001","search_zh":"水、废水 PN-EN ISO 13395:2001","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536b2","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu Kjeldahla Zakres: (0,40 – 500) mg/l Metoda miareczkowa","methodology_en":"Kjeldahl nitrogen concentration Range: (0,40 – 500) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla Zakres: (0,40 – 500) mg/l Metoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla Zakres: (0,40 – 500) mg/l Metoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla Zakres: (0,40 – 500) mg/l Metoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":47,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Kjeldahl nitrogen concentration Range: (0,40 – 500) mg/l Titrimetric method PN-EN 25663:2001","search_zh":"水、废水 PN-EN 25663:2001","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536b3","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-02/WR wydanie 1 z dnia 01.06.2021 r.","norm_bases":["PB-02/WR wydanie 1 z dnia 01.06.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu ogólnego (z obliczeń) PB-02/WR wydanie 1 z dnia 01.06.2021 r. Woda, scieki Stezenie azotu ogolnego (z obliczen) PB-02/WR wydanie 1 z dnia 01.06.2021 r.","categories":["water"],"row_index":48,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Total nitrogen concentration (calculated) PB-02/WR wydanie 1 z dnia 01.06.2021 r.","methodology_zh":"总氮浓度（计算值）","search_zh":"水、废水 总氮浓度（计算值） PB-02/WR wydanie 1 z dnia 01.06.2021 r.","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536b4","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu amonowego Zakres: (0,40 – 500) mg/l Stężenie jonu amonowego Zakres: (0,50 – 644) mg/l Metoda miareczkowa","methodology_en":"Ammonium nitrogen concentration Range: (0,40 – 500) mg/l Ammonium ion concentration Range: (0,50 – 644) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego Zakres: (0,40 – 500) mg/l Stężenie jonu amonowego Zakres: (0,50 – 644) mg/l Metoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu amonowego Zakres: (0,40 – 500) mg/l Stężenie jonu amonowego Zakres: (0,50 – 644) mg/l Metoda miareczkowa PN-ISO 5664:2002 Woda, scieki Stezenie azotu amonowego Zakres: (0,40 – 500) mg/l Stezenie jonu amonowego Zakres: (0,50 – 644) mg/l Metoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":49,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Ammonium nitrogen concentration Range: (0,40 – 500) mg/l Ammonium ion concentration Range: (0,50 – 644) mg/l Titrimetric method PN-ISO 5664:2002","search_zh":"水、废水 PN-ISO 5664:2002","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536b5","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Indeks fenolowy Zakres: (0,001 – 1,00) mg/l Metoda analizy przepływowej (CFA) z detekcją spektrometryczną","methodology_en":"Phenol index Range: (0,001 – 1,00) mg/l Flow analysis method (CFA) with spectrometric detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indeks fenolowy Zakres: (0,001 – 1,00) mg/l Metoda analizy przepływowej (CFA) z detekcją spektrometryczną","reference":"PN-EN ISO 14402:2004","norm_bases":["PN-EN ISO 14402:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Indeks fenolowy Zakres: (0,001 – 1,00) mg/l Metoda analizy przepływowej (CFA) z detekcją spektrometryczną PN-EN ISO 14402:2004 Woda, scieki Indeks fenolowy Zakres: (0,001 – 1,00) mg/l Metoda analizy przeplywowej (CFA) z detekcja spektrometryczna PN-EN ISO 14402:2004","categories":["water"],"row_index":50,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Phenol index Range: (0,001 – 1,00) mg/l Flow analysis method (CFA) with spectrometric detection PN-EN ISO 14402:2004","search_zh":"水、废水 PN-EN ISO 14402:2004","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536b6","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie fosforu ogólnego Zakres: (0,010 – 100) mg/l Metoda analizy przepływowej (CFA) z detekcją spektrometryczną","methodology_en":"Total phosphorus concentration Range: (0,010 – 100) mg/l Flow analysis method (CFA) with spectrometric detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego Zakres: (0,010 – 100) mg/l Metoda analizy przepływowej (CFA) z detekcją spektrometryczną","reference":"PN-EN 15681-2:2019-02","norm_bases":["PN-EN 15681-2:2019-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie fosforu ogólnego Zakres: (0,010 – 100) mg/l Metoda analizy przepływowej (CFA) z detekcją spektrometryczną PN-EN 15681-2:2019-02 Woda, scieki Stezenie fosforu ogolnego Zakres: (0,010 – 100) mg/l Metoda analizy przeplywowej (CFA) z detekcja spektrometryczna PN-EN 15681-2:2019-02","categories":["water"],"row_index":51,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Total phosphorus concentration Range: (0,010 – 100) mg/l Flow analysis method (CFA) with spectrometric detection PN-EN 15681-2:2019-02","search_zh":"水、废水 PN-EN 15681-2:2019-02","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536b7","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Indeks oleju mineralnego Zakres: (0,20 – 15,0) mg/l Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","methodology_en":"Mineral oil index Range: (0,20 – 15,0) mg/l Gas chromatography with flame ionisation detection (GC-FID)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indeks oleju mineralnego Zakres: (0,20 – 15,0) mg/l Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Indeks oleju mineralnego Zakres: (0,20 – 15,0) mg/l Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda, scieki Indeks oleju mineralnego Zakres: (0,20 – 15,0) mg/l Metoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":52,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Mineral oil index Range: (0,20 – 15,0) mg/l Gas chromatography with flame ionisation detection (GC-FID) PN-EN ISO 9377-2:2003","search_zh":"水、废水 PN-EN ISO 9377-2:2003","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536b8","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie substancji ekstrahujących się eterem naftowym Zakres: (5,0 – 100) mg/l Metoda wagowa","methodology_en":"Concentration of substances extractable with petroleum ether Range: (5,0 – 100) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym Zakres: (5,0 – 100) mg/l Metoda wagowa","reference":"PN-86/C-04573/01","norm_bases":["PN-86/C-04573/01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie substancji ekstrahujących się eterem naftowym Zakres: (5,0 – 100) mg/l Metoda wagowa PN-86/C-04573/01 Woda, scieki Stezenie substancji ekstrahujacych sie eterem naftowym Zakres: (5,0 – 100) mg/l Metoda wagowa PN-86/C-04573/01","categories":["water"],"row_index":53,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Concentration of substances extractable with petroleum ether Range: (5,0 – 100) mg/l Gravimetric method PN-86/C-04573/01","search_zh":"水、废水 PN-86/C-04573/01","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536b9","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Wody opadowe Wody roztopowe","test_object_en":"Rainwater Snowmelt water","methodology":"Zawiesiny ogólne Zakres: (5,0 – 6000) mg/l Metoda wagowa","methodology_en":"Total suspended solids (TSS) Range: (5,0 – 6000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: (5,0 – 6000) mg/l Metoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wody opadowe Wody roztopowe Zawiesiny ogólne Zakres: (5,0 – 6000) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007 Wody opadowe Wody roztopowe Zawiesiny ogolne Zakres: (5,0 – 6000) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":54,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rainwater Snowmelt water Total suspended solids (TSS) Range: (5,0 – 6000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007","search_zh":"雨水 融雪水 总悬浮物 范围：(5,0 – 6000) mg/l 重量法 PN-EN 872:2007+Ap1:2007","test_object_zh":"雨水 融雪水","methodology_zh":"总悬浮物 范围：(5,0 – 6000) mg/l 重量法"},{"_id":"6a5a55fe9af9f73f382536ba","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Wody opadowe Wody roztopowe","test_object_en":"Rainwater Snowmelt water","methodology":"Indeks oleju mineralnego Zakres: (0,20 – 150) mg/l Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","methodology_en":"Mineral oil index Range: (0,20 – 150) mg/l Gas chromatography with flame ionisation detection (GC-FID)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indeks oleju mineralnego Zakres: (0,20 – 150) mg/l Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wody opadowe Wody roztopowe Indeks oleju mineralnego Zakres: (0,20 – 150) mg/l Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Wody opadowe Wody roztopowe Indeks oleju mineralnego Zakres: (0,20 – 150) mg/l Metoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":55,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rainwater Snowmelt water Mineral oil index Range: (0,20 – 150) mg/l Gas chromatography with flame ionisation detection (GC-FID) PN-EN ISO 9377-2:2003","search_zh":"雨水 融雪水 PN-EN ISO 9377-2:2003","test_object_zh":"雨水 融雪水"},{"_id":"6a5a55fe9af9f73f382536bb","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Gleba, osady ściekowe","test_object_en":"Soil, sewage sludge","methodology":"Zawartość rtęci Zakres: (0,020 – 10,0) mg/kg Metoda atomowej spektrometrii absorpcyjnej z techniką amalgamacji","methodology_en":"Mercury content Range: (0,020 – 10,0) mg/kg Atomic absorption spectrometry with amalgamation technique method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość rtęci Zakres: (0,020 – 10,0) mg/kg Metoda atomowej spektrometrii absorpcyjnej z techniką amalgamacji","reference":"PB-34/WR-PWR wydanie 1 z dnia 01.06.2021 r.","norm_bases":["PB-34/WR-PWR wydanie 1 z dnia 01.06.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba, osady ściekowe Zawartość rtęci Zakres: (0,020 – 10,0) mg/kg Metoda atomowej spektrometrii absorpcyjnej z techniką amalgamacji PB-34/WR-PWR wydanie 1 z dnia 01.06.2021 r. Gleba, osady sciekowe Zawartosc rteci Zakres: (0,020 – 10,0) mg/kg Metoda atomowej spektrometrii absorpcyjnej z technika amalgamacji PB-34/WR-PWR wydanie 1 z dnia 01.06.2021 r.","categories":["water","environment"],"row_index":56,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil, sewage sludge Mercury content Range: (0,020 – 10,0) mg/kg Atomic absorption spectrometry with amalgamation technique method PB-34/WR-PWR wydanie 1 z dnia 01.06.2021 r.","search_zh":"土壤、污水污泥 PB-34/WR-PWR wydanie 1 z dnia 01.06.2021 r.","test_object_zh":"土壤、污水污泥"},{"_id":"6a5a55fe9af9f73f382536bc","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Sucha masa Zakres: (10,0 – 100) % Metoda wagowa","methodology_en":"Dry matter Range: (10,0 – 100) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sucha masa Zakres: (10,0 – 100) % Metoda wagowa","reference":"ISO 11465:1999","norm_bases":["ISO 11465:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Sucha masa Zakres: (10,0 – 100) % Metoda wagowa ISO 11465:1999 Gleba Sucha masa Zakres: (10,0 – 100) % Metoda wagowa ISO 11465:1999","categories":["environment"],"row_index":57,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Dry matter Range: (10,0 – 100) % Gravimetric method ISO 11465:1999","search_zh":"土壤 ISO 11465:1999","test_object_zh":"土壤"},{"_id":"6a5a55fe9af9f73f382536bd","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość wody (z obliczeń)","methodology_en":"Water content (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wody (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość wody (z obliczeń) Gleba Zawartosc wody (z obliczen)","categories":["water","environment"],"row_index":58,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Water content (calculated)","search_zh":"土壤 水分含量（计算值）","test_object_zh":"土壤","methodology_zh":"水分含量（计算值）"},{"_id":"6a5a55fe9af9f73f382536be","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"pH Zakres: (2,0 – 12,0) Metoda potencjometryczna","methodology_en":"pH Range: (2,0 – 12,0) Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: (2,0 – 12,0) Metoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba pH Zakres: (2,0 – 12,0) Metoda potencjometryczna PN-EN ISO 10390:2022-09 Gleba pH Zakres: (2,0 – 12,0) Metoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":59,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil pH Range: (2,0 – 12,0) Potentiometric method PN-EN ISO 10390:2022-09","search_zh":"土壤 pH 范围：(2,0 – 12,0) 电位法 PN-EN ISO 10390:2022-09","test_object_zh":"土壤","methodology_zh":"pH 范围：(2,0 – 12,0) 电位法"},{"_id":"6a5a55fe9af9f73f382536bf","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"pH Zakres (2,0 – 14,0) Metoda potencjometryczna","methodology_en":"pH Range (2,0 – 14,0) Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres (2,0 – 14,0) Metoda potencjometryczna","reference":"PN-EN 12176:2004","norm_bases":["PN-EN 12176:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe pH Zakres (2,0 – 14,0) Metoda potencjometryczna PN-EN 12176:2004 Osady sciekowe pH Zakres (2,0 – 14,0) Metoda potencjometryczna PN-EN 12176:2004","categories":["water"],"row_index":60,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge pH Range (2,0 – 14,0) Potentiometric method PN-EN 12176:2004","search_zh":"污泥 PN-EN 12176:2004","test_object_zh":"污泥"},{"_id":"6a5a55fe9af9f73f382536c0","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Sucha masa Zakres: (1,0 – 99,5) % Metoda wagowa","methodology_en":"Dry matter Range: (1,0 – 99,5) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sucha masa Zakres: (1,0 – 99,5) % Metoda wagowa","reference":"PN-EN 12880:2004","norm_bases":["PN-EN 12880:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Sucha masa Zakres: (1,0 – 99,5) % Metoda wagowa PN-EN 12880:2004 Osady sciekowe Sucha masa Zakres: (1,0 – 99,5) % Metoda wagowa PN-EN 12880:2004","categories":["water"],"row_index":61,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge Dry matter Range: (1,0 – 99,5) % Gravimetric method PN-EN 12880:2004","search_zh":"污泥 PN-EN 12880:2004","test_object_zh":"污泥"},{"_id":"6a5a55fe9af9f73f382536c1","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Wyciągi wodne przygotowane w Pracowni w Jeleniej Górze z odpadów O): kod 10 09 10, 19 01 12","test_object_en":"Aqueous extracts prepared at the Laboratory in Jelenia Góra from waste O): code 10 09 10, 19 01 12","methodology":"Stężenie/ zawartość anionów Zakres: - chlorki (1,0 – 1000) mg/l (10 – 10000) mg/kg - siarczany (1,0 – 1000) mg/l (10 – 10000) mg/kg Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","methodology_en":"Concentration/ content of anions Range: - chlorides (1,0 – 1000) mg/l (10 – 10000) mg/kg - sulphates (1,0 – 1000) mg/l (10 – 10000) mg/kg Ion chromatography method with conductometric detection (IC-CD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie/ zawartość anionów Zakres: - chlorki (1,0 – 1000) mg/l (10 – 10000) mg/kg - siarczany (1,0 – 1000) mg/l (10 – 10000) mg/kg Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyciągi wodne przygotowane w Pracowni w Jeleniej Górze z odpadów O): kod 10 09 10, 19 01 12 Stężenie/ zawartość anionów Zakres: - chlorki (1,0 – 1000) mg/l (10 – 10000) mg/kg - siarczany (1,0 – 1000) mg/l (10 – 10000) mg/kg Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Wyciagi wodne przygotowane w Pracowni w Jeleniej Gorze z odpadow O): kod 10 09 10, 19 01 12 Stezenie/ zawartosc anionow Zakres: - chlorki (1,0 – 1000) mg/l (10 – 10000) mg/kg - siarczany (1,0 – 1000) mg/l (10 – 10000) mg/kg Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["environment"],"row_index":62,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Aqueous extracts prepared at the Laboratory in Jelenia Góra from waste O): code 10 09 10, 19 01 12 Concentration/ content of anions Range: - chlorides (1,0 – 1000) mg/l (10 – 10000) mg/kg - sulphates (1,0 – 1000) mg/l (10 – 10000) mg/kg Ion chromatography method with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","search_zh":"耶莱尼亚古拉检验室制备的废物 O) 水浸出液：代码 10 09 10、19 01 12 PN-EN ISO 10304-1:2009+AC:2012","test_object_zh":"耶莱尼亚古拉检验室制备的废物 O) 水浸出液：代码 10 09 10、19 01 12"},{"_id":"6a5a55fe9af9f73f382536c2","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Wyciągi wodne przygotowane w Pracowni w Jeleniej Górze z odpadów O): kod 10 09 10, 19 01 12","test_object_en":"Aqueous extracts prepared at the Laboratory in Jelenia Góra from waste O): code 10 09 10, 19 01 12","methodology":"Całkowite substancje rozpuszczone (TDS) Zakres: (20 – 10000) mg/l (200 – 100000) mg/kg Metoda wagowa","methodology_en":"Total dissolved solids (TDS) Range: (20 – 10000) mg/l (200 – 100000) mg/kg Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Całkowite substancje rozpuszczone (TDS) Zakres: (20 – 10000) mg/l (200 – 100000) mg/kg Metoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyciągi wodne przygotowane w Pracowni w Jeleniej Górze z odpadów O): kod 10 09 10, 19 01 12 Całkowite substancje rozpuszczone (TDS) Zakres: (20 – 10000) mg/l (200 – 100000) mg/kg Metoda wagowa PN-EN 15216:2022-03 Wyciagi wodne przygotowane w Pracowni w Jeleniej Gorze z odpadow O): kod 10 09 10, 19 01 12 Calkowite substancje rozpuszczone (TDS) Zakres: (20 – 10000) mg/l (200 – 100000) mg/kg Metoda wagowa PN-EN 15216:2022-03","categories":["environment"],"row_index":63,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Aqueous extracts prepared at the Laboratory in Jelenia Góra from waste O): code 10 09 10, 19 01 12 Total dissolved solids (TDS) Range: (20 – 10000) mg/l (200 – 100000) mg/kg Gravimetric method PN-EN 15216:2022-03","search_zh":"耶莱尼亚古拉检验室制备的废物 O) 水浸出液：代码 10 09 10、19 01 12 PN-EN 15216:2022-03","test_object_zh":"耶莱尼亚古拉检验室制备的废物 O) 水浸出液：代码 10 09 10、19 01 12"},{"_id":"6a5a55fe9af9f73f382536c3","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Wyciągi wodne przygotowane w Pracowni w Jeleniej Górze z odpadów O): kod 10 09 10, 19 01 12","test_object_en":"Aqueous extracts prepared at the Laboratory in Jelenia Góra from waste O): code 10 09 10, 19 01 12","methodology":"Indeks fenolowy Zakres: (0,001 – 1,0) mg/l (0,01 – 10,0) mg/kg Metoda analizy przepływowej (CFA) z detekcją spektrometryczną","methodology_en":"Phenol index Range: (0,001 – 1,0) mg/l (0,01 – 10,0) mg/kg Flow analysis method (CFA) with spectrometric detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indeks fenolowy Zakres: (0,001 – 1,0) mg/l (0,01 – 10,0) mg/kg Metoda analizy przepływowej (CFA) z detekcją spektrometryczną","reference":"PN-EN ISO 14402:2004","norm_bases":["PN-EN ISO 14402:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyciągi wodne przygotowane w Pracowni w Jeleniej Górze z odpadów O): kod 10 09 10, 19 01 12 Indeks fenolowy Zakres: (0,001 – 1,0) mg/l (0,01 – 10,0) mg/kg Metoda analizy przepływowej (CFA) z detekcją spektrometryczną PN-EN ISO 14402:2004 Wyciagi wodne przygotowane w Pracowni w Jeleniej Gorze z odpadow O): kod 10 09 10, 19 01 12 Indeks fenolowy Zakres: (0,001 – 1,0) mg/l (0,01 – 10,0) mg/kg Metoda analizy przeplywowej (CFA) z detekcja spektrometryczna PN-EN ISO 14402:2004","categories":["environment"],"row_index":64,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Aqueous extracts prepared at the Laboratory in Jelenia Góra from waste O): code 10 09 10, 19 01 12 Phenol index Range: (0,001 – 1,0) mg/l (0,01 – 10,0) mg/kg Flow analysis method (CFA) with spectrometric detection PN-EN ISO 14402:2004","search_zh":"耶莱尼亚古拉检验室制备的废物 O) 水浸出液：代码 10 09 10、19 01 12 PN-EN ISO 14402:2004","test_object_zh":"耶莱尼亚古拉检验室制备的废物 O) 水浸出液：代码 10 09 10、19 01 12"},{"_id":"6a5a55fe9af9f73f382536c4","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Odpady O): kod 10 09 10, 19 01 12","test_object_en":"Waste O): code 10 09 10, 19 01 12","methodology":"Sucha masa Zakres: (10,0 – 99) % Metoda wagowa","methodology_en":"Dry matter Range: (10,0 – 99) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sucha masa Zakres: (10,0 – 99) % Metoda wagowa","reference":"PN-EN 15934:2013-02 Metoda A","norm_bases":["PN-EN 15934:2013-02 Metoda A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 10 09 10, 19 01 12 Sucha masa Zakres: (10,0 – 99) % Metoda wagowa PN-EN 15934:2013-02 Metoda A Odpady O): kod 10 09 10, 19 01 12 Sucha masa Zakres: (10,0 – 99) % Metoda wagowa PN-EN 15934:2013-02 Metoda A","categories":["environment"],"row_index":65,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste O): code 10 09 10, 19 01 12 Dry matter Range: (10,0 – 99) % Gravimetric method PN-EN 15934:2013-02 Metoda A","search_zh":"废物 O)：代码 10 09 10、19 01 12 PN-EN 15934:2013-02 Metoda A","test_object_zh":"废物 O)：代码 10 09 10、19 01 12"},{"_id":"6a5a55fe9af9f73f382536c5","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Zawiesiny ogólne Zakres: (5,0 – 6000) mg/l Metoda wagowa","methodology_en":"Total suspended solids (TSS) Range: (5,0 – 6000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: (5,0 – 6000) mg/l Metoda wagowa","reference":"PN-EN 872:2007+Ap.1:2007","norm_bases":["PN-EN 872:2007+Ap.1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Zawiesiny ogólne Zakres: (5,0 – 6000) mg/l Metoda wagowa PN-EN 872:2007+Ap.1:2007 Woda, scieki Zawiesiny ogolne Zakres: (5,0 – 6000) mg/l Metoda wagowa PN-EN 872:2007+Ap.1:2007","categories":["water"],"row_index":66,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Total suspended solids (TSS) Range: (5,0 – 6000) mg/l Gravimetric method PN-EN 872:2007+Ap.1:2007","search_zh":"水、废水 总悬浮物 范围：(5,0 – 6000) mg/l 重量法 PN-EN 872:2007+Ap.1:2007","test_object_zh":"水、废水","methodology_zh":"总悬浮物 范围：(5,0 – 6000) mg/l 重量法"},{"_id":"6a5a55fe9af9f73f382536c6","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT ,BZT 5 2+5 Zakres: (5,0 – 6000) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD ,BOD 5 2+5 Range: (5,0 – 6000) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT ,BZT 5 2+5 Zakres: (5,0 – 6000) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT ,BZT 5 2+5 Zakres: (5,0 – 6000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT ,BZT 5 2+5 Zakres: (5,0 – 6000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":67,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Biochemical oxygen demand - BOD ,BOD 5 2+5 Range: (5,0 – 6000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12","search_zh":"水、废水 PN-EN ISO 5815-1:2019-12","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536c7","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Zawiesiny ogólne Zakres: (3,0 – 10000) mg/l Metoda wagowa","methodology_en":"Total suspended solids Range: (3,0 – 10000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: (3,0 – 10000) mg/l Metoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Zawiesiny ogólne Zakres: (3,0 – 10000) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne Zakres: (3,0 – 10000) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":68,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Total suspended solids Range: (3,0 – 10000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007","search_zh":"水、废水 PN-EN 872:2007+Ap1:2007","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536c8","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Całkowite substancje rozpuszczone (TDS) Zakres: (20 – 20000) mg/l Metoda wagowa","methodology_en":"Total dissolved solids (TDS) Range: (20 – 20000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Całkowite substancje rozpuszczone (TDS) Zakres: (20 – 20000) mg/l Metoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Całkowite substancje rozpuszczone (TDS) Zakres: (20 – 20000) mg/l Metoda wagowa PN-EN 15216:2022-03 Woda, scieki Calkowite substancje rozpuszczone (TDS) Zakres: (20 – 20000) mg/l Metoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":69,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Total dissolved solids (TDS) Range: (20 – 20000) mg/l Gravimetric method PN-EN 15216:2022-03","search_zh":"水、废水 PN-EN 15216:2022-03","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536c9","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie chlorków Zakres: (5,0 – 10000) mg/l Metoda miareczkowa","methodology_en":"Chloride concentration Range: (5,0 – 10000) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (5,0 – 10000) mg/l Metoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie chlorków Zakres: (5,0 – 10000) mg/l Metoda miareczkowa PN-ISO 9297:1994 Woda, scieki Stezenie chlorkow Zakres: (5,0 – 10000) mg/l Metoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":70,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Chloride concentration Range: (5,0 – 10000) mg/l Titrimetric method PN-ISO 9297:1994","search_zh":"水、废水 PN-ISO 9297:1994","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536ca","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu amonowego Zakres: (0,01 – 778) mg/l Stężenie jonu amonowego Zakres: (0,01 – 1000) mg/l Metoda spektrofotometryczna","methodology_en":"Ammonium nitrogen concentration Range: (0,01 – 778) mg/l Ammonium ion concentration Range: (0,01 – 1000) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego Zakres: (0,01 – 778) mg/l Stężenie jonu amonowego Zakres: (0,01 – 1000) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu amonowego Zakres: (0,01 – 778) mg/l Stężenie jonu amonowego Zakres: (0,01 – 1000) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, scieki Stezenie azotu amonowego Zakres: (0,01 – 778) mg/l Stezenie jonu amonowego Zakres: (0,01 – 1000) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":71,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Ammonium nitrogen concentration Range: (0,01 – 778) mg/l Ammonium ion concentration Range: (0,01 – 1000) mg/l Spectrophotometric method PN-ISO 7150-1:2002","search_zh":"水、废水 PN-ISO 7150-1:2002","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536cb","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu azotanowego Zakres: (0,1 – 225) mg/l Stężenie azotanów Zakres: (0,4 – 1000) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrate nitrogen concentration Range: (0,1 – 225) mg/l Nitrate concentration Range: (0,4 – 1000) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego Zakres: (0,1 – 225) mg/l Stężenie azotanów Zakres: (0,4 – 1000) mg/l Metoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu azotanowego Zakres: (0,1 – 225) mg/l Stężenie azotanów Zakres: (0,4 – 1000) mg/l Metoda spektrofotometryczna PN-82/C-04576.08 Woda, scieki Stezenie azotu azotanowego Zakres: (0,1 – 225) mg/l Stezenie azotanow Zakres: (0,4 – 1000) mg/l Metoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":72,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Nitrate nitrogen concentration Range: (0,1 – 225) mg/l Nitrate concentration Range: (0,4 – 1000) mg/l Spectrophotometric method PN-82/C-04576.08","search_zh":"水、废水 PN-82/C-04576.08","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536cc","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu azotynowego Zakres: (0,001 – 300) mg/l Stężenie azotynów Zakres: (0,003 – 1000) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrite nitrogen concentration Range: (0,001 – 300) mg/l Nitrite concentration Range: (0,003 – 1000) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego Zakres: (0,001 – 300) mg/l Stężenie azotynów Zakres: (0,003 – 1000) mg/l Metoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu azotynowego Zakres: (0,001 – 300) mg/l Stężenie azotynów Zakres: (0,003 – 1000) mg/l Metoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego Zakres: (0,001 – 300) mg/l Stezenie azotynow Zakres: (0,003 – 1000) mg/l Metoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":73,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Nitrite nitrogen concentration Range: (0,001 – 300) mg/l Nitrite concentration Range: (0,003 – 1000) mg/l Spectrophotometric method PN-EN 26777:1999","search_zh":"水、废水 PN-EN 26777:1999","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536cd","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie ortofosforanów Zakres: (0,010 – 1000) mg/l Metoda spektrofotometryczna","methodology_en":"Orthophosphate concentration Range: (0,010 – 1000) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie ortofosforanów Zakres: (0,010 – 1000) mg/l Metoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 + Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 + Ap1:2010 +Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie ortofosforanów Zakres: (0,010 – 1000) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 + Ap1:2010 +Ap2:2010 Woda, scieki Stezenie ortofosforanow Zakres: (0,010 – 1000) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 + Ap1:2010 +Ap2:2010","categories":["water"],"row_index":74,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Orthophosphate concentration Range: (0,010 – 1000) mg/l Spectrophotometric method PN-EN ISO 6878:2006 + Ap1:2010 +Ap2:2010","search_zh":"水、废水 PN-EN ISO 6878:2006 + Ap1:2010 +Ap2:2010","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536ce","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie fosforu ogólnego Zakres: (0,029 – 326) mg/l Metoda spektrofotometryczna","methodology_en":"Total phosphorus concentration Range: (0,029 – 326) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego Zakres: (0,029 – 326) mg/l Metoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 + Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 + Ap1:2010 +Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie fosforu ogólnego Zakres: (0,029 – 326) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 + Ap1:2010 +Ap2:2010 Woda, scieki Stezenie fosforu ogolnego Zakres: (0,029 – 326) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 + Ap1:2010 +Ap2:2010","categories":["water"],"row_index":75,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Total phosphorus concentration Range: (0,029 – 326) mg/l Spectrophotometric method PN-EN ISO 6878:2006 + Ap1:2010 +Ap2:2010","search_zh":"水、废水 PN-EN ISO 6878:2006 + Ap1:2010 +Ap2:2010","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536cf","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie ogólnego węgla organicznego (OWO) Zakres: (0,5 – 1000 ) mg/l Metoda spektrometrii w zakresie podczerwieni (IR)","methodology_en":"Total organic carbon (TOC) concentration Range: (0,5 – 1000 ) mg/l Infrared range spectrometry method (IR)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie ogólnego węgla organicznego (OWO) Zakres: (0,5 – 1000 ) mg/l Metoda spektrometrii w zakresie podczerwieni (IR)","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie ogólnego węgla organicznego (OWO) Zakres: (0,5 – 1000 ) mg/l Metoda spektrometrii w zakresie podczerwieni (IR) PN-EN 1484:1999 Woda, scieki Stezenie ogolnego wegla organicznego (OWO) Zakres: (0,5 – 1000 ) mg/l Metoda spektrometrii w zakresie podczerwieni (IR) PN-EN 1484:1999","categories":["water"],"row_index":76,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Total organic carbon (TOC) concentration Range: (0,5 – 1000 ) mg/l Infrared range spectrometry method (IR) PN-EN 1484:1999","search_zh":"水、废水 PN-EN 1484:1999","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536d0","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie anionów Zakres: chlorki: (0,05 – 1000) mg/l azot azotanowy: (0,04 – 22,6) mg/l azotany: (0,18 – 100) mg/l siarczany: (0,24 – 1000) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","methodology_en":"Anion concentrations Range: chlorides: (0,05 – 1000) mg/l nitrate nitrogen: (0,04 – 22,6) mg/l nitrates: (0,18 – 100) mg/l sulfates: (0,24 – 1000) mg/l Ion chromatography with conductometric detection (IC-CD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie anionów Zakres: chlorki: (0,05 – 1000) mg/l azot azotanowy: (0,04 – 22,6) mg/l azotany: (0,18 – 100) mg/l siarczany: (0,24 – 1000) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie anionów Zakres: chlorki: (0,05 – 1000) mg/l azot azotanowy: (0,04 – 22,6) mg/l azotany: (0,18 – 100) mg/l siarczany: (0,24 – 1000) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, scieki Stezenie anionow Zakres: chlorki: (0,05 – 1000) mg/l azot azotanowy: (0,04 – 22,6) mg/l azotany: (0,18 – 100) mg/l siarczany: (0,24 – 1000) mg/l Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":77,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Anion concentrations Range: chlorides: (0,05 – 1000) mg/l nitrate nitrogen: (0,04 – 22,6) mg/l nitrates: (0,18 – 100) mg/l sulfates: (0,24 – 1000) mg/l Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","search_zh":"水、废水 PN-EN ISO 10304-1:2009+AC:2012","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536d1","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie metali Zakres: glin (0,010 – 1000) mg/l arsen (0,005 – 1000) mg/l bor (0,010 – 1000) mg/l bar (0,001 – 1000) mg/l beryl (0,0001 – 1000) mg/l kadm (0,0005 – 1000) mg/l kobalt (0,002 – 1000) mg/l chrom (0,002 – 1000) mg/l miedź (0,005 – 1000) mg/l żelazo (0,005 – 1000) mg/l mangan (0,001 – 1000) mg/l molibden (0,001 – 1000) mg/l nikiel (0,0025 – 1000) mg/l ołów (0,0025 – 1000) mg/l selen (0,010 – 1000) mg/l srebro (0,001 – 1000) mg/l tytan (0,001 – 1000) mg/l wanad (0,001 – 1000) mg/l cynk (0,010 – 1000) mg/l sód (0,05 – 1000) mg/l potas (0,05 – 1000) mg/l wapń (0,10 – 1000) mg/l magnez (0,01 – 1000) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","methodology_en":"Metal concentrations Range: aluminium (0,010 – 1000) mg/l arsenic (0,005 – 1000) mg/l boron (0,010 – 1000) mg/l barium (0,001 – 1000) mg/l beryllium (0,0001 – 1000) mg/l cadmium (0,0005 – 1000) mg/l cobalt (0,002 – 1000) mg/l chromium (0,002 – 1000) mg/l copper (0,005 – 1000) mg/l iron (0,005 – 1000) mg/l manganese (0,001 – 1000) mg/l molybdenum (0,001 – 1000) mg/l nickel (0,0025 – 1000) mg/l lead (0,0025 – 1000) mg/l selenium (0,010 – 1000) mg/l silver (0,001 – 1000) mg/l titanium (0,001 – 1000) mg/l vanadium (0,001 – 1000) mg/l zinc (0,010 – 1000) mg/l sodium (0,05 – 1000) mg/l potassium (0,05 – 1000) mg/l calcium (0,10 – 1000) mg/l magnesium (0,01 – 1000) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie metali Zakres: glin (0,010 – 1000) mg/l arsen (0,005 – 1000) mg/l bor (0,010 – 1000) mg/l bar (0,001 – 1000) mg/l beryl (0,0001 – 1000) mg/l kadm (0,0005 – 1000) mg/l kobalt (0,002 – 1000) mg/l chrom (0,002 – 1000) mg/l miedź (0,005 – 1000) mg/l żelazo (0,005 – 1000) mg/l mangan (0,001 – 1000) mg/l molibden (0,001 – 1000) mg/l nikiel (0,0025 – 1000) mg/l ołów (0,0025 – 1000) mg/l selen (0,010 – 1000) mg/l srebro (0,001 – 1000) mg/l tytan (0,001 – 1000) mg/l wanad (0,001 – 1000) mg/l cynk (0,010 – 1000) mg/l sód (0,05 – 1000) mg/l potas (0,05 – 1000) mg/l wapń (0,10 – 1000) mg/l magnez (0,01 – 1000) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885: 2009","norm_bases":["PN-EN ISO 11885: 2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie metali Zakres: glin (0,010 – 1000) mg/l arsen (0,005 – 1000) mg/l bor (0,010 – 1000) mg/l bar (0,001 – 1000) mg/l beryl (0,0001 – 1000) mg/l kadm (0,0005 – 1000) mg/l kobalt (0,002 – 1000) mg/l chrom (0,002 – 1000) mg/l miedź (0,005 – 1000) mg/l żelazo (0,005 – 1000) mg/l mangan (0,001 – 1000) mg/l molibden (0,001 – 1000) mg/l nikiel (0,0025 – 1000) mg/l ołów (0,0025 – 1000) mg/l selen (0,010 – 1000) mg/l srebro (0,001 – 1000) mg/l tytan (0,001 – 1000) mg/l wanad (0,001 – 1000) mg/l cynk (0,010 – 1000) mg/l sód (0,05 – 1000) mg/l potas (0,05 – 1000) mg/l wapń (0,10 – 1000) mg/l magnez (0,01 – 1000) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885: 2009 Woda, scieki Stezenie metali Zakres: glin (0,010 – 1000) mg/l arsen (0,005 – 1000) mg/l bor (0,010 – 1000) mg/l bar (0,001 – 1000) mg/l beryl (0,0001 – 1000) mg/l kadm (0,0005 – 1000) mg/l kobalt (0,002 – 1000) mg/l chrom (0,002 – 1000) mg/l miedz (0,005 – 1000) mg/l zelazo (0,005 – 1000) mg/l mangan (0,001 – 1000) mg/l molibden (0,001 – 1000) mg/l nikiel (0,0025 – 1000) mg/l olow (0,0025 – 1000) mg/l selen (0,010 – 1000) mg/l srebro (0,001 – 1000) mg/l tytan (0,001 – 1000) mg/l wanad (0,001 – 1000) mg/l cynk (0,010 – 1000) mg/l sod (0,05 – 1000) mg/l potas (0,05 – 1000) mg/l wapn (0,10 – 1000) mg/l magnez (0,01 – 1000) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885: 2009","categories":["materials","water"],"row_index":78,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Metal concentrations Range: aluminium (0,010 – 1000) mg/l arsenic (0,005 – 1000) mg/l boron (0,010 – 1000) mg/l barium (0,001 – 1000) mg/l beryllium (0,0001 – 1000) mg/l cadmium (0,0005 – 1000) mg/l cobalt (0,002 – 1000) mg/l chromium (0,002 – 1000) mg/l copper (0,005 – 1000) mg/l iron (0,005 – 1000) mg/l manganese (0,001 – 1000) mg/l molybdenum (0,001 – 1000) mg/l nickel (0,0025 – 1000) mg/l lead (0,0025 – 1000) mg/l selenium (0,010 – 1000) mg/l silver (0,001 – 1000) mg/l titanium (0,001 – 1000) mg/l vanadium (0,001 – 1000) mg/l zinc (0,010 – 1000) mg/l sodium (0,05 – 1000) mg/l potassium (0,05 – 1000) mg/l calcium (0,10 – 1000) mg/l magnesium (0,01 – 1000) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885: 2009","search_zh":"水、废水 PN-EN ISO 11885: 2009","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536d2","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie metali Zakres: glin (0,0050 – 1000) mg/l arsen (0,0010 – 20) mg/l bor (0,0050 – 1000) mg/l bar (0,0010 – 1000) mg/l beryl (0,0010 – 20) mg/l kadm (0,0010 – 1000) mg/l kobalt (0,0010 – 1000) mg/l chrom (0,0010 – 1000) mg/l miedź (0,0010 – 1000) mg/l żelazo (0,0050 – 1000) mg/l mangan (0,0010 – 1000) mg/l molibden (0,0050 – 20) mg/l nikiel (0,0010 – 1000) mg/l ołów (0,0010 – 1000) mg/l selen (0,0050 – 20) mg/l srebro (0,00025 – 1000) mg/l tytan (0,0010 – 20) mg/l wanad (0,0010 – 20) mg/l cynk (0,0050 – 1000) mg/l sód (0,10 – 1000) mg/l potas (0,10 – 1000) mg/l wapń (0,10 – 1000) mg/l magnez (0,10 – 1000) mg/l tal (0,0010 – 1000) mg/l cyna (0,0010 – 20) mg/l antymon (0,0010 – 20) mg/l Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","methodology_en":"Metal concentrations Range: aluminium (0,0050 – 1000) mg/l arsenic (0,0010 – 20) mg/l boron (0,0050 – 1000) mg/l barium (0,0010 – 1000) mg/l beryllium (0,0010 – 20) mg/l cadmium (0,0010 – 1000) mg/l cobalt (0,0010 – 1000) mg/l chromium (0,0010 – 1000) mg/l copper (0,0010 – 1000) mg/l iron (0,0050 – 1000) mg/l manganese (0,0010 – 1000) mg/l molybdenum (0,0050 – 20) mg/l nickel (0,0010 – 1000) mg/l lead (0,0010 – 1000) mg/l selenium (0,0050 – 20) mg/l silver (0,00025 – 1000) mg/l titanium (0,0010 – 20) mg/l vanadium (0,0010 – 20) mg/l zinc (0,0050 – 1000) mg/l sodium (0,10 – 1000) mg/l potassium (0,10 – 1000) mg/l calcium (0,10 – 1000) mg/l magnesium (0,10 – 1000) mg/l thallium (0,0010 – 1000) mg/l tin (0,0010 – 20) mg/l antimony (0,0010 – 20) mg/l Inductively coupled plasma mass spectrometry (ICP-MS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie metali Zakres: glin (0,0050 – 1000) mg/l arsen (0,0010 – 20) mg/l bor (0,0050 – 1000) mg/l bar (0,0010 – 1000) mg/l beryl (0,0010 – 20) mg/l kadm (0,0010 – 1000) mg/l kobalt (0,0010 – 1000) mg/l chrom (0,0010 – 1000) mg/l miedź (0,0010 – 1000) mg/l żelazo (0,0050 – 1000) mg/l mangan (0,0010 – 1000) mg/l molibden (0,0050 – 20) mg/l nikiel (0,0010 – 1000) mg/l ołów (0,0010 – 1000) mg/l selen (0,0050 – 20) mg/l srebro (0,00025 – 1000) mg/l tytan (0,0010 – 20) mg/l wanad (0,0010 – 20) mg/l cynk (0,0050 – 1000) mg/l sód (0,10 – 1000) mg/l potas (0,10 – 1000) mg/l wapń (0,10 – 1000) mg/l magnez (0,10 – 1000) mg/l tal (0,0010 – 1000) mg/l cyna (0,0010 – 20) mg/l antymon (0,0010 – 20) mg/l Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN ISO 17294-2:2024-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie metali Zakres: glin (0,0050 – 1000) mg/l arsen (0,0010 – 20) mg/l bor (0,0050 – 1000) mg/l bar (0,0010 – 1000) mg/l beryl (0,0010 – 20) mg/l kadm (0,0010 – 1000) mg/l kobalt (0,0010 – 1000) mg/l chrom (0,0010 – 1000) mg/l miedź (0,0010 – 1000) mg/l żelazo (0,0050 – 1000) mg/l mangan (0,0010 – 1000) mg/l molibden (0,0050 – 20) mg/l nikiel (0,0010 – 1000) mg/l ołów (0,0010 – 1000) mg/l selen (0,0050 – 20) mg/l srebro (0,00025 – 1000) mg/l tytan (0,0010 – 20) mg/l wanad (0,0010 – 20) mg/l cynk (0,0050 – 1000) mg/l sód (0,10 – 1000) mg/l potas (0,10 – 1000) mg/l wapń (0,10 – 1000) mg/l magnez (0,10 – 1000) mg/l tal (0,0010 – 1000) mg/l cyna (0,0010 – 20) mg/l antymon (0,0010 – 20) mg/l Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN ISO 17294-2:2024-04 Woda, scieki Stezenie metali Zakres: glin (0,0050 – 1000) mg/l arsen (0,0010 – 20) mg/l bor (0,0050 – 1000) mg/l bar (0,0010 – 1000) mg/l beryl (0,0010 – 20) mg/l kadm (0,0010 – 1000) mg/l kobalt (0,0010 – 1000) mg/l chrom (0,0010 – 1000) mg/l miedz (0,0010 – 1000) mg/l zelazo (0,0050 – 1000) mg/l mangan (0,0010 – 1000) mg/l molibden (0,0050 – 20) mg/l nikiel (0,0010 – 1000) mg/l olow (0,0010 – 1000) mg/l selen (0,0050 – 20) mg/l srebro (0,00025 – 1000) mg/l tytan (0,0010 – 20) mg/l wanad (0,0010 – 20) mg/l cynk (0,0050 – 1000) mg/l sod (0,10 – 1000) mg/l potas (0,10 – 1000) mg/l wapn (0,10 – 1000) mg/l magnez (0,10 – 1000) mg/l tal (0,0010 – 1000) mg/l cyna (0,0010 – 20) mg/l antymon (0,0010 – 20) mg/l Metoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN ISO 17294-2:2024-04","categories":["materials","water"],"row_index":79,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Metal concentrations Range: aluminium (0,0050 – 1000) mg/l arsenic (0,0010 – 20) mg/l boron (0,0050 – 1000) mg/l barium (0,0010 – 1000) mg/l beryllium (0,0010 – 20) mg/l cadmium (0,0010 – 1000) mg/l cobalt (0,0010 – 1000) mg/l chromium (0,0010 – 1000) mg/l copper (0,0010 – 1000) mg/l iron (0,0050 – 1000) mg/l manganese (0,0010 – 1000) mg/l molybdenum (0,0050 – 20) mg/l nickel (0,0010 – 1000) mg/l lead (0,0010 – 1000) mg/l selenium (0,0050 – 20) mg/l silver (0,00025 – 1000) mg/l titanium (0,0010 – 20) mg/l vanadium (0,0010 – 20) mg/l zinc (0,0050 – 1000) mg/l sodium (0,10 – 1000) mg/l potassium (0,10 – 1000) mg/l calcium (0,10 – 1000) mg/l magnesium (0,10 – 1000) mg/l thallium (0,0010 – 1000) mg/l tin (0,0010 – 20) mg/l antimony (0,0010 – 20) mg/l Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN ISO 17294-2:2024-04","search_zh":"水、废水 PN-EN ISO 17294-2:2024-04","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536d3","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu amonowego Zakres: (0,078 – 778) mg/l N-NH 4 (0,10 – 1000) mg/l NH 4 Metoda analizy przepływowej (CFA) z detekcją spektrofotometryczną","methodology_en":"Ammonium nitrogen concentration Range: (0,078 – 778) mg/l N-NH 4 (0,10 – 1000) mg/l NH 4 Flow analysis (CFA) with spectrophotometric detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego Zakres: (0,078 – 778) mg/l N-NH 4 (0,10 – 1000) mg/l NH 4 Metoda analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"EN ISO 11732:2007","norm_bases":["EN ISO 11732:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu amonowego Zakres: (0,078 – 778) mg/l N-NH 4 (0,10 – 1000) mg/l NH 4 Metoda analizy przepływowej (CFA) z detekcją spektrofotometryczną EN ISO 11732:2007 Woda, scieki Stezenie azotu amonowego Zakres: (0,078 – 778) mg/l N-NH 4 (0,10 – 1000) mg/l NH 4 Metoda analizy przeplywowej (CFA) z detekcja spektrofotometryczna EN ISO 11732:2007","categories":["water"],"row_index":80,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Ammonium nitrogen concentration Range: (0,078 – 778) mg/l N-NH 4 (0,10 – 1000) mg/l NH 4 Flow analysis (CFA) with spectrophotometric detection EN ISO 11732:2007","search_zh":"水、废水 EN ISO 11732:2007","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536d4","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu azotynowego Zakres: N-NO (0,001 – 300) mg/l 2 NO (0,003 – 1000) mg/l 2 Metoda analizy przepływowej (CFA) z detekcją spektrofotometryczną","methodology_en":"Nitrite nitrogen concentration Range: N-NO (0,001 – 300) mg/l 2 NO (0,003 – 1000) mg/l 2 Flow analysis (CFA) with spectrophotometric detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego Zakres: N-NO (0,001 – 300) mg/l 2 NO (0,003 – 1000) mg/l 2 Metoda analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu azotynowego Zakres: N-NO (0,001 – 300) mg/l 2 NO (0,003 – 1000) mg/l 2 Metoda analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 13395:2001 Woda, scieki Stezenie azotu azotynowego Zakres: N-NO (0,001 – 300) mg/l 2 NO (0,003 – 1000) mg/l 2 Metoda analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 13395:2001","categories":["water"],"row_index":81,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Nitrite nitrogen concentration Range: N-NO (0,001 – 300) mg/l 2 NO (0,003 – 1000) mg/l 2 Flow analysis (CFA) with spectrophotometric detection PN-EN ISO 13395:2001","search_zh":"水、废水 PN-EN ISO 13395:2001","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536d5","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (5 – 1000) mg/l O 2 Metoda spektrofotometryczna","methodology_en":"Chemical oxygen demand - COD-Cr Range: (5 – 1000) mg/l O 2 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (5 – 1000) mg/l O 2 Metoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (5 – 1000) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (5 – 1000) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":82,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Chemical oxygen demand - COD-Cr Range: (5 – 1000) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005","search_zh":"水、废水 PN-ISO 15705:2005","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536d6","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu Kjeldahla Zakres: (0,2 – 100) mg/l Metoda spektrofotometryczna","methodology_en":"Kjeldahl nitrogen concentration Range: (0,2 – 100) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla Zakres: (0,2 – 100) mg/l Metoda spektrofotometryczna","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla Zakres: (0,2 – 100) mg/l Metoda spektrofotometryczna PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla Zakres: (0,2 – 100) mg/l Metoda spektrofotometryczna PN-EN 25663:2001","categories":["water"],"row_index":83,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Kjeldahl nitrogen concentration Range: (0,2 – 100) mg/l Spectrophotometric method PN-EN 25663:2001","search_zh":"水、废水 PN-EN 25663:2001","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536d7","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie rtęci Zakres: (0,01 – 40) g/l Metoda atomowej spektrometrii fluorescencyjnej (ASF)","methodology_en":"Mercury concentration Range: (0,01 – 40) g/l Atomic fluorescence spectrometry method (ASF)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie rtęci Zakres: (0,01 – 40) g/l Metoda atomowej spektrometrii fluorescencyjnej (ASF)","reference":"PN-EN ISO 17852:2009","norm_bases":["PN-EN ISO 17852:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie rtęci Zakres: (0,01 – 40) g/l Metoda atomowej spektrometrii fluorescencyjnej (ASF) PN-EN ISO 17852:2009 Woda, scieki Stezenie rteci Zakres: (0,01 – 40) g/l Metoda atomowej spektrometrii fluorescencyjnej (ASF) PN-EN ISO 17852:2009","categories":["water"],"row_index":84,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Mercury concentration Range: (0,01 – 40) g/l Atomic fluorescence spectrometry method (ASF) PN-EN ISO 17852:2009","search_zh":"水、废水 PN-EN ISO 17852:2009","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536d8","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie fosforu ogólnego Zakres: (0,0050 – 1000) mg/l Metoda emisyjnej spektrofotometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","methodology_en":"Total phosphorus concentration Range: (0,0050 – 1000) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego Zakres: (0,0050 – 1000) mg/l Metoda emisyjnej spektrofotometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie fosforu ogólnego Zakres: (0,0050 – 1000) mg/l Metoda emisyjnej spektrofotometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, scieki Stezenie fosforu ogolnego Zakres: (0,0050 – 1000) mg/l Metoda emisyjnej spektrofotometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":85,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Total phosphorus concentration Range: (0,0050 – 1000) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009","search_zh":"水、废水 PN-EN ISO 11885:2009","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536d9","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT , BZT 5 2+5 Zakres: (3 – 6000) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD , BOD 5 2+5 Range: (3 – 6000) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT , BZT 5 2+5 Zakres: (3 – 6000) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Biochemiczne zapotrzebowanie tlenu - BZT , BZT 5 2+5 Zakres: (3 – 6000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda Biochemiczne zapotrzebowanie tlenu - BZT , BZT 5 2+5 Zakres: (3 – 6000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":86,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Biochemical oxygen demand - BOD , BOD 5 2+5 Range: (3 – 6000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12","search_zh":"水 PN-EN ISO 5815-1:2019-12","test_object_zh":"水"},{"_id":"6a5a55fe9af9f73f382536da","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie selenu Zakres: (0,005 – 0,25) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","methodology_en":"Selenium concentration Range: (0,005 – 0,25) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie selenu Zakres: (0,005 – 0,25) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885: 2009","norm_bases":["PN-EN ISO 11885: 2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie selenu Zakres: (0,005 – 0,25) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885: 2009 Woda Stezenie selenu Zakres: (0,005 – 0,25) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885: 2009","categories":["water"],"row_index":87,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Selenium concentration Range: (0,005 – 0,25) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885: 2009","search_zh":"水 PN-EN ISO 11885: 2009","test_object_zh":"水"},{"_id":"6a5a55fe9af9f73f382536db","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3 – 6000) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD 5 Range: (3 – 6000) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3 – 6000) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3 – 6000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3 – 6000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":88,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Biochemical oxygen demand - BOD 5 Range: (3 – 6000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12","search_zh":"污水 五日生化需氧量 BZT 5 范围：(3 – 6000) mg/l O 2 电化学法 PN-EN ISO 5815-1:2019-12","test_object_zh":"污水","methodology_zh":"五日生化需氧量 BZT 5 范围：(3 – 6000) mg/l O 2 电化学法"},{"_id":"6a5a55fe9af9f73f382536dc","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Sucha pozostałość / zawartość wody Zakres: (1,0 – 99) % Metoda wagowa","methodology_en":"Dry residue / water content Range: (1,0 – 99) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sucha pozostałość / zawartość wody Zakres: (1,0 – 99) % Metoda wagowa","reference":"PN-EN 12880:2004","norm_bases":["PN-EN 12880:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Sucha pozostałość / zawartość wody Zakres: (1,0 – 99) % Metoda wagowa PN-EN 12880:2004 Osady sciekowe Sucha pozostalosc / zawartosc wody Zakres: (1,0 – 99) % Metoda wagowa PN-EN 12880:2004","categories":["water"],"row_index":89,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge Dry residue / water content Range: (1,0 – 99) % Gravimetric method PN-EN 12880:2004","search_zh":"污泥 干残渣/水分含量 范围：(1,0 – 99) % 重量法 PN-EN 12880:2004","test_object_zh":"污泥","methodology_zh":"干残渣/水分含量 范围：(1,0 – 99) % 重量法"},{"_id":"6a5a55fe9af9f73f382536dd","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Straty przy prażeniu suchej masy (LOI) Zakres: (1,0 – 99) % Metoda wagowa","methodology_en":"Loss on ignition of dry matter (LOI) Range: (1,0 – 99) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Straty przy prażeniu suchej masy (LOI) Zakres: (1,0 – 99) % Metoda wagowa","reference":"PN-EN 12879:2004","norm_bases":["PN-EN 12879:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Straty przy prażeniu suchej masy (LOI) Zakres: (1,0 – 99) % Metoda wagowa PN-EN 12879:2004 Osady sciekowe Straty przy prazeniu suchej masy (LOI) Zakres: (1,0 – 99) % Metoda wagowa PN-EN 12879:2004","categories":["water"],"row_index":90,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge Loss on ignition of dry matter (LOI) Range: (1,0 – 99) % Gravimetric method PN-EN 12879:2004","search_zh":"污泥 PN-EN 12879:2004","test_object_zh":"污泥"},{"_id":"6a5a55fe9af9f73f382536de","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"pH Zakres: (2,0 – 12,0) Metoda potencjometryczna","methodology_en":"pH Range: (2,0 – 12,0) Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: (2,0 – 12,0) Metoda potencjometryczna","reference":"PN-EN 12176:2004","norm_bases":["PN-EN 12176:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe pH Zakres: (2,0 – 12,0) Metoda potencjometryczna PN-EN 12176:2004 Osady sciekowe pH Zakres: (2,0 – 12,0) Metoda potencjometryczna PN-EN 12176:2004","categories":["water"],"row_index":91,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge pH Range: (2,0 – 12,0) Potentiometric method PN-EN 12176:2004","search_zh":"污泥 pH 范围：(2,0 – 12,0) 电位法 PN-EN 12176:2004","test_object_zh":"污泥","methodology_zh":"pH 范围：(2,0 – 12,0) 电位法"},{"_id":"6a5a55fe9af9f73f382536df","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość azotu Kjeldahla Zakres: (0,2 – 5,0) % Metoda spektrofotometryczna","methodology_en":"Kjeldahl nitrogen content Range: (0,2 – 5,0) % Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość azotu Kjeldahla Zakres: (0,2 – 5,0) % Metoda spektrofotometryczna","reference":"PB-02/WR-PJG wydanie 1 z dnia 30.03.2021 r.","norm_bases":["PB-02/WR-PJG wydanie 1 z dnia 30.03.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość azotu Kjeldahla Zakres: (0,2 – 5,0) % Metoda spektrofotometryczna PB-02/WR-PJG wydanie 1 z dnia 30.03.2021 r. Osady sciekowe Zawartosc azotu Kjeldahla Zakres: (0,2 – 5,0) % Metoda spektrofotometryczna PB-02/WR-PJG wydanie 1 z dnia 30.03.2021 r.","categories":["water"],"row_index":92,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge Kjeldahl nitrogen content Range: (0,2 – 5,0) % Spectrophotometric method PB-02/WR-PJG wydanie 1 z dnia 30.03.2021 r.","search_zh":"污泥 PB-02/WR-PJG wydanie 1 z dnia 30.03.2021 r.","test_object_zh":"污泥"},{"_id":"6a5a55fe9af9f73f382536e0","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość azotu amonowego Zakres: (0,04 – 1,2) % Metoda spektrofotometryczna","methodology_en":"Ammonium nitrogen content Range: (0,04 – 1,2) % Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość azotu amonowego Zakres: (0,04 – 1,2) % Metoda spektrofotometryczna","reference":"PB-03/WR-PJG wydanie 1 z dnia 30.03.2021 r.","norm_bases":["PB-03/WR-PJG wydanie 1 z dnia 30.03.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość azotu amonowego Zakres: (0,04 – 1,2) % Metoda spektrofotometryczna PB-03/WR-PJG wydanie 1 z dnia 30.03.2021 r. Osady sciekowe Zawartosc azotu amonowego Zakres: (0,04 – 1,2) % Metoda spektrofotometryczna PB-03/WR-PJG wydanie 1 z dnia 30.03.2021 r.","categories":["water"],"row_index":93,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge Ammonium nitrogen content Range: (0,04 – 1,2) % Spectrophotometric method PB-03/WR-PJG wydanie 1 z dnia 30.03.2021 r.","search_zh":"污泥 PB-03/WR-PJG wydanie 1 z dnia 30.03.2021 r.","test_object_zh":"污泥"},{"_id":"6a5a55fe9af9f73f382536e1","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość fosforu Zakres: (0,5 – 5,0) % Metoda spektrofotometryczna","methodology_en":"Phosphorus content Range: (0,5 – 5,0) % Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość fosforu Zakres: (0,5 – 5,0) % Metoda spektrofotometryczna","reference":"PB-04/WR-PJG wydanie 1 z dnia 30.03.2021 r.","norm_bases":["PB-04/WR-PJG wydanie 1 z dnia 30.03.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość fosforu Zakres: (0,5 – 5,0) % Metoda spektrofotometryczna PB-04/WR-PJG wydanie 1 z dnia 30.03.2021 r. Osady sciekowe Zawartosc fosforu Zakres: (0,5 – 5,0) % Metoda spektrofotometryczna PB-04/WR-PJG wydanie 1 z dnia 30.03.2021 r.","categories":["water"],"row_index":94,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge Phosphorus content Range: (0,5 – 5,0) % Spectrophotometric method PB-04/WR-PJG wydanie 1 z dnia 30.03.2021 r.","search_zh":"污泥 PB-04/WR-PJG wydanie 1 z dnia 30.03.2021 r.","test_object_zh":"污泥"},{"_id":"6a5a55fe9af9f73f382536e2","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość metali Zakres: ołów (6,25 – 12500) mg/kg kadm (0,125 – 6250) mg/kg nikiel (2,5 – 6250) mg/kg cynk (5,0 – 31250) mg/kg miedź (2,5 – 12500) mg/kg chrom (2,5 – 6250) mg/kg wapń (0,05 – 62,5) % magnez (0,01 – 18,75) % Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","methodology_en":"Metal content Range: lead (6,25 – 12500) mg/kg cadmium (0,125 – 6250) mg/kg nickel (2,5 – 6250) mg/kg zinc (5,0 – 31250) mg/kg copper (2,5 – 12500) mg/kg chromium (2,5 – 6250) mg/kg calcium (0,05 – 62,5) % magnesium (0,01 – 18,75) % Inductively coupled plasma optical emission spectrometry (ICP-OES)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość metali Zakres: ołów (6,25 – 12500) mg/kg kadm (0,125 – 6250) mg/kg nikiel (2,5 – 6250) mg/kg cynk (5,0 – 31250) mg/kg miedź (2,5 – 12500) mg/kg chrom (2,5 – 6250) mg/kg wapń (0,05 – 62,5) % magnez (0,01 – 18,75) % Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009 PN-EN ISO 13346:2002 metoda C","norm_bases":["PN-EN ISO 11885:2009 PN-EN ISO 13346:2002 metoda C"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość metali Zakres: ołów (6,25 – 12500) mg/kg kadm (0,125 – 6250) mg/kg nikiel (2,5 – 6250) mg/kg cynk (5,0 – 31250) mg/kg miedź (2,5 – 12500) mg/kg chrom (2,5 – 6250) mg/kg wapń (0,05 – 62,5) % magnez (0,01 – 18,75) % Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 PN-EN ISO 13346:2002 metoda C Osady sciekowe Zawartosc metali Zakres: olow (6,25 – 12500) mg/kg kadm (0,125 – 6250) mg/kg nikiel (2,5 – 6250) mg/kg cynk (5,0 – 31250) mg/kg miedz (2,5 – 12500) mg/kg chrom (2,5 – 6250) mg/kg wapn (0,05 – 62,5) % magnez (0,01 – 18,75) % Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009 PN-EN ISO 13346:2002 metoda C","categories":["materials","water"],"row_index":95,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge Metal content Range: lead (6,25 – 12500) mg/kg cadmium (0,125 – 6250) mg/kg nickel (2,5 – 6250) mg/kg zinc (5,0 – 31250) mg/kg copper (2,5 – 12500) mg/kg chromium (2,5 – 6250) mg/kg calcium (0,05 – 62,5) % magnesium (0,01 – 18,75) % Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009 PN-EN ISO 13346:2002 metoda C","search_zh":"污泥 PN-EN ISO 11885:2009 PN-EN ISO 13346:2002 metoda C","test_object_zh":"污泥"},{"_id":"6a5a55fe9af9f73f382536e3","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość metali Zakres: arsen (1,25 – 6250) mg/kg bar (0,25 – 6250) mg/kg chrom (2,5 – 6250) mg/kg cynk (5,0 – 31250) mg/kg kadm (0,125 – 6250) mg/kg kobalt (2,5 – 6250) mg/kg miedź (2,5 – 12500) mg/kg nikiel (2,5 – 6250) mg/kg ołów (6,25 – 12500) mg/kg żelazo (1,25 – 31250) mg/kg mangan (0,25 – 31250) mg/kg wanad (2,5 – 6250) mg/kg stront (0,25 – 3125) mg/kg tytan (2,5 – 6250) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","methodology_en":"Metal content Range: arsenic (1,25 – 6250) mg/kg barium (0,25 – 6250) mg/kg chromium (2,5 – 6250) mg/kg zinc (5,0 – 31250) mg/kg cadmium (0,125 – 6250) mg/kg cobalt (2,5 – 6250) mg/kg copper (2,5 – 12500) mg/kg nickel (2,5 – 6250) mg/kg lead (6,25 – 12500) mg/kg iron (1,25 – 31250) mg/kg manganese (0,25 – 31250) mg/kg vanadium (2,5 – 6250) mg/kg strontium (0,25 – 3125) mg/kg titanium (2,5 – 6250) mg/kg Inductively coupled plasma optical emission spectrometry (ICP-OES)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość metali Zakres: arsen (1,25 – 6250) mg/kg bar (0,25 – 6250) mg/kg chrom (2,5 – 6250) mg/kg cynk (5,0 – 31250) mg/kg kadm (0,125 – 6250) mg/kg kobalt (2,5 – 6250) mg/kg miedź (2,5 – 12500) mg/kg nikiel (2,5 – 6250) mg/kg ołów (6,25 – 12500) mg/kg żelazo (1,25 – 31250) mg/kg mangan (0,25 – 31250) mg/kg wanad (2,5 – 6250) mg/kg stront (0,25 – 3125) mg/kg tytan (2,5 – 6250) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009 PN-EN ISO 13346:2002 metoda C","norm_bases":["PN-EN ISO 11885:2009 PN-EN ISO 13346:2002 metoda C"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość metali Zakres: arsen (1,25 – 6250) mg/kg bar (0,25 – 6250) mg/kg chrom (2,5 – 6250) mg/kg cynk (5,0 – 31250) mg/kg kadm (0,125 – 6250) mg/kg kobalt (2,5 – 6250) mg/kg miedź (2,5 – 12500) mg/kg nikiel (2,5 – 6250) mg/kg ołów (6,25 – 12500) mg/kg żelazo (1,25 – 31250) mg/kg mangan (0,25 – 31250) mg/kg wanad (2,5 – 6250) mg/kg stront (0,25 – 3125) mg/kg tytan (2,5 – 6250) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 PN-EN ISO 13346:2002 metoda C Gleba Zawartosc metali Zakres: arsen (1,25 – 6250) mg/kg bar (0,25 – 6250) mg/kg chrom (2,5 – 6250) mg/kg cynk (5,0 – 31250) mg/kg kadm (0,125 – 6250) mg/kg kobalt (2,5 – 6250) mg/kg miedz (2,5 – 12500) mg/kg nikiel (2,5 – 6250) mg/kg olow (6,25 – 12500) mg/kg zelazo (1,25 – 31250) mg/kg mangan (0,25 – 31250) mg/kg wanad (2,5 – 6250) mg/kg stront (0,25 – 3125) mg/kg tytan (2,5 – 6250) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009 PN-EN ISO 13346:2002 metoda C","categories":["materials","environment"],"row_index":96,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Metal content Range: arsenic (1,25 – 6250) mg/kg barium (0,25 – 6250) mg/kg chromium (2,5 – 6250) mg/kg zinc (5,0 – 31250) mg/kg cadmium (0,125 – 6250) mg/kg cobalt (2,5 – 6250) mg/kg copper (2,5 – 12500) mg/kg nickel (2,5 – 6250) mg/kg lead (6,25 – 12500) mg/kg iron (1,25 – 31250) mg/kg manganese (0,25 – 31250) mg/kg vanadium (2,5 – 6250) mg/kg strontium (0,25 – 3125) mg/kg titanium (2,5 – 6250) mg/kg Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009 PN-EN ISO 13346:2002 metoda C","search_zh":"土壤 PN-EN ISO 11885:2009 PN-EN ISO 13346:2002 metoda C","test_object_zh":"土壤"},{"_id":"6a5a55fe9af9f73f382536e4","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Odpady O): kod 10 09 10, 19 01 12","test_object_en":"Waste O): code 10 09 10, 19 01 12","methodology":"Stężenie/ zawartość metali Zakres: arsen (0,005 – 100) mg/l (0,05 – 1000) mg/kg bar (0,001 – 100) mg/l (0,010 – 1000) mg/kg kadm (0,0005 – 100) mg/l (0,005 – 1000) mg/kg chrom (0,002 – 100) mg/l (0,02 – 1000) mg/kg miedź (0,005 – 100) mg/l (0,05 – 1000) mg/kg molibden (0,001 – 100) mg/l (0,01 – 1000) mg/kg nikiel (0,0025 – 100) mg/l (0,025 – 1000) mg/kg ołów (0,0025 – 100) mg/l (0,025 – 1000) mg/kg antymon (0,005 – 100) mg/l (0,05 – 1000) mg/kg selen (0,005 – 100) mg/l (0,05 – 1000) mg/kg cynk (0,010 – 100) mg/l (0,10 – 1000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","methodology_en":"Concentration/ content of metals Range: arsenic (0,005 – 100) mg/l (0,05 – 1000) mg/kg barium (0,001 – 100) mg/l (0,010 – 1000) mg/kg cadmium (0,0005 – 100) mg/l (0,005 – 1000) mg/kg chromium (0,002 – 100) mg/l (0,02 – 1000) mg/kg copper (0,005 – 100) mg/l (0,05 – 1000) mg/kg molybdenum (0,001 – 100) mg/l (0,01 – 1000) mg/kg nickel (0,0025 – 100) mg/l (0,025 – 1000) mg/kg lead (0,0025 – 100) mg/l (0,025 – 1000) mg/kg antimony (0,005 – 100) mg/l (0,05 – 1000) mg/kg selenium (0,005 – 100) mg/l (0,05 – 1000) mg/kg zinc (0,010 – 100) mg/l (0,10 – 1000) mg/kg Inductively coupled plasma optical emission spectrometry (ICP-OES)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie/ zawartość metali Zakres: arsen (0,005 – 100) mg/l (0,05 – 1000) mg/kg bar (0,001 – 100) mg/l (0,010 – 1000) mg/kg kadm (0,0005 – 100) mg/l (0,005 – 1000) mg/kg chrom (0,002 – 100) mg/l (0,02 – 1000) mg/kg miedź (0,005 – 100) mg/l (0,05 – 1000) mg/kg molibden (0,001 – 100) mg/l (0,01 – 1000) mg/kg nikiel (0,0025 – 100) mg/l (0,025 – 1000) mg/kg ołów (0,0025 – 100) mg/l (0,025 – 1000) mg/kg antymon (0,005 – 100) mg/l (0,05 – 1000) mg/kg selen (0,005 – 100) mg/l (0,05 – 1000) mg/kg cynk (0,010 – 100) mg/l (0,10 – 1000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009 PN-EN 12457-4:2006","norm_bases":["PN-EN ISO 11885:2009 PN-EN 12457-4:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 10 09 10, 19 01 12 Stężenie/ zawartość metali Zakres: arsen (0,005 – 100) mg/l (0,05 – 1000) mg/kg bar (0,001 – 100) mg/l (0,010 – 1000) mg/kg kadm (0,0005 – 100) mg/l (0,005 – 1000) mg/kg chrom (0,002 – 100) mg/l (0,02 – 1000) mg/kg miedź (0,005 – 100) mg/l (0,05 – 1000) mg/kg molibden (0,001 – 100) mg/l (0,01 – 1000) mg/kg nikiel (0,0025 – 100) mg/l (0,025 – 1000) mg/kg ołów (0,0025 – 100) mg/l (0,025 – 1000) mg/kg antymon (0,005 – 100) mg/l (0,05 – 1000) mg/kg selen (0,005 – 100) mg/l (0,05 – 1000) mg/kg cynk (0,010 – 100) mg/l (0,10 – 1000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 PN-EN 12457-4:2006 Odpady O): kod 10 09 10, 19 01 12 Stezenie/ zawartosc metali Zakres: arsen (0,005 – 100) mg/l (0,05 – 1000) mg/kg bar (0,001 – 100) mg/l (0,010 – 1000) mg/kg kadm (0,0005 – 100) mg/l (0,005 – 1000) mg/kg chrom (0,002 – 100) mg/l (0,02 – 1000) mg/kg miedz (0,005 – 100) mg/l (0,05 – 1000) mg/kg molibden (0,001 – 100) mg/l (0,01 – 1000) mg/kg nikiel (0,0025 – 100) mg/l (0,025 – 1000) mg/kg olow (0,0025 – 100) mg/l (0,025 – 1000) mg/kg antymon (0,005 – 100) mg/l (0,05 – 1000) mg/kg selen (0,005 – 100) mg/l (0,05 – 1000) mg/kg cynk (0,010 – 100) mg/l (0,10 – 1000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009 PN-EN 12457-4:2006","categories":["materials","environment"],"row_index":97,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste O): code 10 09 10, 19 01 12 Concentration/ content of metals Range: arsenic (0,005 – 100) mg/l (0,05 – 1000) mg/kg barium (0,001 – 100) mg/l (0,010 – 1000) mg/kg cadmium (0,0005 – 100) mg/l (0,005 – 1000) mg/kg chromium (0,002 – 100) mg/l (0,02 – 1000) mg/kg copper (0,005 – 100) mg/l (0,05 – 1000) mg/kg molybdenum (0,001 – 100) mg/l (0,01 – 1000) mg/kg nickel (0,0025 – 100) mg/l (0,025 – 1000) mg/kg lead (0,0025 – 100) mg/l (0,025 – 1000) mg/kg antimony (0,005 – 100) mg/l (0,05 – 1000) mg/kg selenium (0,005 – 100) mg/l (0,05 – 1000) mg/kg zinc (0,010 – 100) mg/l (0,10 – 1000) mg/kg Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009 PN-EN 12457-4:2006","search_zh":"废物 O)：代码 10 09 10、19 01 12 PN-EN ISO 11885:2009 PN-EN 12457-4:2006","test_object_zh":"废物 O)：代码 10 09 10、19 01 12"},{"_id":"6a5a55fe9af9f73f382536e5","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Odpady O): kod 10 09 10, 19 01 12","test_object_en":"Waste O): code 10 09 10, 19 01 12","methodology":"Stężenie/ zawartość rozpuszczonego węgla organicznego Zakres: (0,5 – 1000) mg/l (5 – 10000) mg/kg Metoda spektrometrii w zakresie podczerwieni (IR)","methodology_en":"Concentration/ content of dissolved organic carbon Range: (0,5 – 1000) mg/l (5 – 10000) mg/kg Infrared spectrometry method (IR)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie/ zawartość rozpuszczonego węgla organicznego Zakres: (0,5 – 1000) mg/l (5 – 10000) mg/kg Metoda spektrometrii w zakresie podczerwieni (IR)","reference":"PN-EN 1484:1999 PN-EN 12457-4:2006","norm_bases":["PN-EN 1484:1999 PN-EN 12457-4:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 10 09 10, 19 01 12 Stężenie/ zawartość rozpuszczonego węgla organicznego Zakres: (0,5 – 1000) mg/l (5 – 10000) mg/kg Metoda spektrometrii w zakresie podczerwieni (IR) PN-EN 1484:1999 PN-EN 12457-4:2006 Odpady O): kod 10 09 10, 19 01 12 Stezenie/ zawartosc rozpuszczonego wegla organicznego Zakres: (0,5 – 1000) mg/l (5 – 10000) mg/kg Metoda spektrometrii w zakresie podczerwieni (IR) PN-EN 1484:1999 PN-EN 12457-4:2006","categories":["environment"],"row_index":98,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste O): code 10 09 10, 19 01 12 Concentration/ content of dissolved organic carbon Range: (0,5 – 1000) mg/l (5 – 10000) mg/kg Infrared spectrometry method (IR) PN-EN 1484:1999 PN-EN 12457-4:2006","search_zh":"废物 O)：代码 10 09 10、19 01 12 PN-EN 1484:1999 PN-EN 12457-4:2006","test_object_zh":"废物 O)：代码 10 09 10、19 01 12"},{"_id":"6a5a55fe9af9f73f382536e6","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu amonowego Zakres: (3,0 – 1000) mg/l Stężenie jonu amonowego Zakres: (3,9 – 1290) mg/l Metoda miareczkowa","methodology_en":"Ammonium nitrogen concentration Range: (3,0 – 1000) mg/l Ammonium ion concentration Range: (3,9 – 1290) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego Zakres: (3,0 – 1000) mg/l Stężenie jonu amonowego Zakres: (3,9 – 1290) mg/l Metoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu amonowego Zakres: (3,0 – 1000) mg/l Stężenie jonu amonowego Zakres: (3,9 – 1290) mg/l Metoda miareczkowa PN-ISO 5664:2002 Woda, scieki Stezenie azotu amonowego Zakres: (3,0 – 1000) mg/l Stezenie jonu amonowego Zakres: (3,9 – 1290) mg/l Metoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":99,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Ammonium nitrogen concentration Range: (3,0 – 1000) mg/l Ammonium ion concentration Range: (3,9 – 1290) mg/l Titrimetric method PN-ISO 5664:2002","search_zh":"水、废水 PN-ISO 5664:2002","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536e7","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu amonowego Zakres: (0,025 – 8,0) mg/l Stężenie jonu amonowego Zakres: (0,032 – 10) mg/l Metoda spektrofotometryczna","methodology_en":"Ammonium nitrogen concentration Range: (0,025 – 8,0) mg/l Ammonium ion concentration Range: (0,032 – 10) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego Zakres: (0,025 – 8,0) mg/l Stężenie jonu amonowego Zakres: (0,032 – 10) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu amonowego Zakres: (0,025 – 8,0) mg/l Stężenie jonu amonowego Zakres: (0,032 – 10) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, scieki Stezenie azotu amonowego Zakres: (0,025 – 8,0) mg/l Stezenie jonu amonowego Zakres: (0,032 – 10) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":100,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Ammonium nitrogen concentration Range: (0,025 – 8,0) mg/l Ammonium ion concentration Range: (0,032 – 10) mg/l Spectrophotometric method PN-ISO 7150-1:2002","search_zh":"水、废水 PN-ISO 7150-1:2002","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536e8","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu Kjeldahla Zakres: (0,5 – 3,0) mg/l Metoda spektrofotometryczna","methodology_en":"Kjeldahl nitrogen concentration Range: (0,5 – 3,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla Zakres: (0,5 – 3,0) mg/l Metoda spektrofotometryczna","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla Zakres: (0,5 – 3,0) mg/l Metoda spektrofotometryczna PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla Zakres: (0,5 – 3,0) mg/l Metoda spektrofotometryczna PN-EN 25663:2001","categories":["water"],"row_index":101,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Kjeldahl nitrogen concentration Range: (0,5 – 3,0) mg/l Spectrophotometric method PN-EN 25663:2001","search_zh":"水、废水 PN-EN 25663:2001","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536e9","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu Kjeldahla Zakres: (3,0 – 1000) mg/l Metoda miareczkowa","methodology_en":"Kjeldahl nitrogen concentration Range: (3,0 – 1000) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla Zakres: (3,0 – 1000) mg/l Metoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla Zakres: (3,0 – 1000) mg/l Metoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla Zakres: (3,0 – 1000) mg/l Metoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":102,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Kjeldahl nitrogen concentration Range: (3,0 – 1000) mg/l Titrimetric method PN-EN 25663:2001","search_zh":"水、废水 PN-EN 25663:2001","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536ea","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu azotynowego Zakres: (0,0025 – 20) mg/l Stężenie azotynów Zakres: (0,008 – 66) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrite nitrogen concentration Range: (0,0025 – 20) mg/l Nitrite concentration Range: (0,008 – 66) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego Zakres: (0,0025 – 20) mg/l Stężenie azotynów Zakres: (0,008 – 66) mg/l Metoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu azotynowego Zakres: (0,0025 – 20) mg/l Stężenie azotynów Zakres: (0,008 – 66) mg/l Metoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego Zakres: (0,0025 – 20) mg/l Stezenie azotynow Zakres: (0,008 – 66) mg/l Metoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":103,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Nitrite nitrogen concentration Range: (0,0025 – 20) mg/l Nitrite concentration Range: (0,008 – 66) mg/l Spectrophotometric method PN-EN 26777:1999","search_zh":"水、废水 PN-EN 26777:1999","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536eb","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie ortofosforanów Zakres: (0,031 – 123) mg/l Metoda spektrofotometryczna","methodology_en":"Orthophosphate concentration Range: (0,031 – 123) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie ortofosforanów Zakres: (0,031 – 123) mg/l Metoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie ortofosforanów Zakres: (0,031 – 123) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010 Woda, scieki Stezenie ortofosforanow Zakres: (0,031 – 123) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","categories":["water"],"row_index":104,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Orthophosphate concentration Range: (0,031 – 123) mg/l Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","search_zh":"水、废水 PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536ec","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie fosforu ogólnego Zakres: (0,010 – 40) mg/l Metoda spektrofotometryczna","methodology_en":"Total phosphorus concentration Range: (0,010 – 40) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego Zakres: (0,010 – 40) mg/l Metoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie fosforu ogólnego Zakres: (0,010 – 40) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010 Woda, scieki Stezenie fosforu ogolnego Zakres: (0,010 – 40) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","categories":["water"],"row_index":105,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Total phosphorus concentration Range: (0,010 – 40) mg/l Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","search_zh":"水、废水 PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536ed","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (8 – 125) mg/l O 2 Metoda spektrofotometryczna","methodology_en":"Chemical oxygen demand - COD-Cr Range: (8 – 125) mg/l O 2 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (8 – 125) mg/l O 2 Metoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (8 – 125) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (8 – 125) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":106,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Chemical oxygen demand - COD-Cr Range: (8 – 125) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005","search_zh":"水、废水 PN-ISO 15705:2005","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536ee","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT BZT 5, 2+5 Zakres: (3,0 – 6000) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD BOD 5, 2+5 Range: (3,0 – 6000) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT BZT 5, 2+5 Zakres: (3,0 – 6000) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT BZT 5, 2+5 Zakres: (3,0 – 6000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT BZT 5, 2+5 Zakres: (3,0 – 6000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":107,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Biochemical oxygen demand - BOD BOD 5, 2+5 Range: (3,0 – 6000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12","search_zh":"水、废水 PN-EN ISO 5815-1:2019-12","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536ef","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT BZT 5, 2+5 Zakres: (0,5 – 6,0) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD BOD 5, 2+5 Range: (0,5 – 6,0) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT BZT 5, 2+5 Zakres: (0,5 – 6,0) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT BZT 5, 2+5 Zakres: (0,5 – 6,0) mg/l O 2 Metoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT BZT 5, 2+5 Zakres: (0,5 – 6,0) mg/l O 2 Metoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":108,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Biochemical oxygen demand - BOD BOD 5, 2+5 Range: (0,5 – 6,0) mg/l O 2 Electrochemical method PN-EN 1899-2:2002","search_zh":"水、废水 PN-EN 1899-2:2002","test_object_zh":"水、废水"},{"_id":"6a5a55fe9af9f73f382536f0","lab_id":"69ad52a3de79e566650fb101","country":"PL","accr_number":"AB 075","accr_body":"PCA","test_object":"Woda, ścieki Wody opadowe Wody roztopowe","test_object_en":"Water, wastewater Rainwater Snowmelt water","methodology":"Zawiesiny ogólne Zakres: (5,0 – 2000) mg/l Metoda wagowa","methodology_en":"Total suspended solids (TSS) Range: (5,0 – 2000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: (5,0 – 2000) mg/l Metoda wagowa","reference":"PN-EN 872:2007+ Ap1:2007","norm_bases":["PN-EN 872:2007+ Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Wody opadowe Wody roztopowe Zawiesiny ogólne Zakres: (5,0 – 2000) mg/l Metoda wagowa PN-EN 872:2007+ Ap1:2007 Woda, scieki Wody opadowe Wody roztopowe Zawiesiny ogolne Zakres: (5,0 – 2000) mg/l Metoda wagowa PN-EN 872:2007+ Ap1:2007","categories":["water"],"row_index":109,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Rainwater Snowmelt water Total suspended solids (TSS) Range: (5,0 – 2000) mg/l Gravimetric method PN-EN 872:2007+ Ap1:2007","methodology_zh":"总悬浮物 范围：(5,0 – 2000) mg/l 重量法","search_zh":"总悬浮物 范围：(5,0 – 2000) mg/l 重量法 PN-EN 872:2007+ Ap1:2007"}],"has_pdf":true}