{"lab":{"_id":"69ad52a3de79e566650fb0ff","accr_number":"AB 074","country":"PL","accr_body":"PCA","address":"LABORATORIUM BADAWCZE APARATURY ELEKTROENERGETYCZNEJ (LAE), ul. Pożaryskiego 28, 04-703 Warszawa","categories":["construction","materials","electronics","environment"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":96,"name":"SIEĆ BADAWCZA ŁUKASIEWICZ - INSTYTUT ELEKTROTECHNIKI","parse_status":"parsed","parse_version":3,"pdf_files":["AB_074.pdf"],"scope_summary":"","search_text":"sieć badawcza łukasiewicz - instytut elektrotechniki laboratorium badawcze aparatury elektroenergetycznej (lae), ul. pożaryskiego 28, 04-703 warszawa construction pharma electronics other materials metrology water automotive environment","status":"active","updated_at":"2026-03-08T14:50:08.396Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-14T12:36:09.322Z","parse_date":"2026-08-14T12:36:09.322Z","parse_source":"agent-claude-code","email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20074,podmiot.html","fields_of_testing":[{"codes":"E/6; E/19; E/54","pl":"Badania elektryczne wyrobów i wyposażenia elektrycznego, środków ochrony osobistej, wyrobów i wyposażenia elektronicznego","en":"Electric tests of electrical products and equipment, personal protection equipment, electronic products and equipment"},{"codes":"J/6; J/54","pl":"Badania mechaniczne wyrobów i wyposażenia elektrycznego, wyrobów i wyposażenia elektronicznego","en":"Mechanical tests of electrical products and equipment, electronic products and equipment"},{"codes":"N/6; N/54","pl":"Badania właściwości fizycznych wyrobów i wyposażenia elektrycznego, wyrobów i wyposażenia elektronicznego","en":"Tests of physical properties of electrical products and equipment, electronic products and equipment"}],"issue":{"no":"26","date":"07.01.2026"},"map_coord":[52.207157,21.173926],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM BADAWCZE APARATURY ELEKTROENERGETYCZNEJ (LAE)","address":null,"city":null,"postal":null},{"name":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/14/d3fd592f678d8ba33723712cd82573c6/AB%20074.pdf","has_en":true,"category_counts":{"other":49,"construction":37,"materials":13,"electronics":8,"environment":5},"category_scores":{"other":21.44,"construction":12.22,"materials":1.51,"electronics":0.57,"environment":0.22},"has_zh":true},"methods":[{"_id":"6a7f0bb91995264369d8e252","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Wyłączniki wysokonapięciowe prądu przemiennego / Alternating-current high voltage circuit-breakers","methodology":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:","parameters":[{"name":"udarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV"},{"name":"przemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV","reference":"PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | PN-EN IEC 62271-101:2022-04 | IEC 62271-101:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","norm_bases":["PN-EN IEC 62271-100:2022-04","IEC 62271-100:2021","PN-EN IEC 62271-101:2022-04","IEC 62271-101:2021","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyłączniki wysokonapięciowe prądu przemiennego / Alternating-current high voltage circuit-breakers Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | PN-EN IEC 62271-101:2022-04 | IEC 62271-101:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 Wylaczniki wysokonapieciowe pradu przemiennego / Alternating-current high voltage circuit-breakers Wytrzymalosc elektryczna izolacji napieciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | PN-EN IEC 62271-101:2022-04 | IEC 62271-101:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","categories":["construction"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | PN-EN IEC 62271-101:2022-04 | IEC 62271-101:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021"},{"_id":"6a7f0bb91995264369d8e253","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Wyłączniki wysokonapięciowe prądu przemiennego / Alternating-current high voltage circuit-breakers","methodology":"Graniczne przyrosty temperatury / Temperature rise tests","parameters":[{"name":"Zakres / Range","range":"do 12 kA / up to and including 12 kA"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 12 kA / up to and including 12 kA","reference":"PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | PN-EN IEC 62271-101:2022-04 | IEC 62271-101:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","norm_bases":["PN-EN IEC 62271-100:2022-04","IEC 62271-100:2021","PN-EN IEC 62271-101:2022-04","IEC 62271-101:2021","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyłączniki wysokonapięciowe prądu przemiennego / Alternating-current high voltage circuit-breakers Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 12 kA / up to and including 12 kA PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | PN-EN IEC 62271-101:2022-04 | IEC 62271-101:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 Wylaczniki wysokonapieciowe pradu przemiennego / Alternating-current high voltage circuit-breakers Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 12 kA / up to and including 12 kA PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | PN-EN IEC 62271-101:2022-04 | IEC 62271-101:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","categories":["other"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 12 kA / up to and including 12 kA"}],"search_en":"Range Reference documents PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | PN-EN IEC 62271-101:2022-04 | IEC 62271-101:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","parameters_zh":[{"name":"范围 / Range","range":"do 12 kA / up to and including 12 kA"}],"search_zh":"范围 / Range PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | PN-EN IEC 62271-101:2022-04 | IEC 62271-101:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021"},{"_id":"6a7f0bb91995264369d8e254","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Wyłączniki wysokonapięciowe prądu przemiennego / Alternating-current high voltage circuit-breakers","methodology":"Rezystancja obwodu głównego / Main circuit resistance","parameters":[{"name":"Zakres / Range","range":"od 10-5 Ω / from 10-5 Ω"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Rezystancja obwodu głównego / Main circuit resistance\nZakres / Range od 10-5 Ω / from 10-5 Ω","reference":"PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | PN-EN IEC 62271-101:2022-04 | IEC 62271-101:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","norm_bases":["PN-EN IEC 62271-100:2022-04","IEC 62271-100:2021","PN-EN IEC 62271-101:2022-04","IEC 62271-101:2021","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyłączniki wysokonapięciowe prądu przemiennego / Alternating-current high voltage circuit-breakers Rezystancja obwodu głównego / Main circuit resistance\nZakres / Range od 10-5 Ω / from 10-5 Ω PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | PN-EN IEC 62271-101:2022-04 | IEC 62271-101:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 Wylaczniki wysokonapieciowe pradu przemiennego / Alternating-current high voltage circuit-breakers Rezystancja obwodu glownego / Main circuit resistance\nZakres / Range od 10-5 Ω / from 10-5 Ω PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | PN-EN IEC 62271-101:2022-04 | IEC 62271-101:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","categories":["other"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"od 10-5 Ω / from 10-5 Ω"}],"search_en":"Range Reference documents PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | PN-EN IEC 62271-101:2022-04 | IEC 62271-101:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","parameters_zh":[{"name":"范围 / Range","range":"od 10-5 Ω / from 10-5 Ω"}],"search_zh":"范围 / Range PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | PN-EN IEC 62271-101:2022-04 | IEC 62271-101:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021"},{"_id":"6a7f0bb91995264369d8e255","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Wyłączniki wysokonapięciowe prądu przemiennego / Alternating-current high voltage circuit-breakers","methodology":"Wytrzymałość zwarciowa / Short-circuit tests","parameters":[{"name":"Zakres / Range","range":"do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość zwarciowa / Short-circuit tests\nZakres / Range do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak","reference":"PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | PN-EN IEC 62271-101:2022-04 | IEC 62271-101:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","norm_bases":["PN-EN IEC 62271-100:2022-04","IEC 62271-100:2021","PN-EN IEC 62271-101:2022-04","IEC 62271-101:2021","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyłączniki wysokonapięciowe prądu przemiennego / Alternating-current high voltage circuit-breakers Wytrzymałość zwarciowa / Short-circuit tests\nZakres / Range do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | PN-EN IEC 62271-101:2022-04 | IEC 62271-101:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 Wylaczniki wysokonapieciowe pradu przemiennego / Alternating-current high voltage circuit-breakers Wytrzymalosc zwarciowa / Short-circuit tests\nZakres / Range do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | PN-EN IEC 62271-101:2022-04 | IEC 62271-101:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","categories":["other"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak"}],"search_en":"Range Reference documents PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | PN-EN IEC 62271-101:2022-04 | IEC 62271-101:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","parameters_zh":[{"name":"范围 / Range","range":"do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak"}],"search_zh":"范围 / Range PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | PN-EN IEC 62271-101:2022-04 | IEC 62271-101:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021"},{"_id":"6a7f0bb91995264369d8e256","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Wyłączniki wysokonapięciowe prądu przemiennego / Alternating-current high voltage circuit-breakers","methodology":"Niezawodność działania i trwałość mechaniczna / Mechanical operation. Mechanical endurance","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Niezawodność działania i trwałość mechaniczna / Mechanical operation. Mechanical endurance","reference":"PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | PN-EN IEC 62271-101:2022-04 | IEC 62271-101:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","norm_bases":["PN-EN IEC 62271-100:2022-04","IEC 62271-100:2021","PN-EN IEC 62271-101:2022-04","IEC 62271-101:2021","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyłączniki wysokonapięciowe prądu przemiennego / Alternating-current high voltage circuit-breakers Niezawodność działania i trwałość mechaniczna / Mechanical operation. Mechanical endurance PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | PN-EN IEC 62271-101:2022-04 | IEC 62271-101:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 Wylaczniki wysokonapieciowe pradu przemiennego / Alternating-current high voltage circuit-breakers Niezawodnosc dzialania i trwalosc mechaniczna / Mechanical operation. Mechanical endurance PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | PN-EN IEC 62271-101:2022-04 | IEC 62271-101:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","categories":["other"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | PN-EN IEC 62271-101:2022-04 | IEC 62271-101:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021"},{"_id":"6a7f0bb91995264369d8e257","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Wyłączniki wysokonapięciowe prądu przemiennego / Alternating-current high voltage circuit-breakers","methodology":"Zdolność łączenia / Making and breaking capacity","parameters":[{"name":"Zakres / Range","range":"do 50 kA / up to and including 50 kA"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Zdolność łączenia / Making and breaking capacity\nZakres / Range do 50 kA / up to and including 50 kA","reference":"PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | PN-EN IEC 62271-101:2022-04 | IEC 62271-101:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","norm_bases":["PN-EN IEC 62271-100:2022-04","IEC 62271-100:2021","PN-EN IEC 62271-101:2022-04","IEC 62271-101:2021","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyłączniki wysokonapięciowe prądu przemiennego / Alternating-current high voltage circuit-breakers Zdolność łączenia / Making and breaking capacity\nZakres / Range do 50 kA / up to and including 50 kA PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | PN-EN IEC 62271-101:2022-04 | IEC 62271-101:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 Wylaczniki wysokonapieciowe pradu przemiennego / Alternating-current high voltage circuit-breakers Zdolnosc laczenia / Making and breaking capacity\nZakres / Range do 50 kA / up to and including 50 kA PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | PN-EN IEC 62271-101:2022-04 | IEC 62271-101:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","categories":["other"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 50 kA / up to and including 50 kA"}],"search_en":"Range Reference documents PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | PN-EN IEC 62271-101:2022-04 | IEC 62271-101:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","parameters_zh":[{"name":"范围 / Range","range":"do 50 kA / up to and including 50 kA"}],"search_zh":"范围 / Range PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | PN-EN IEC 62271-101:2022-04 | IEC 62271-101:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021"},{"_id":"6a7f0bb91995264369d8e258","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Autoreklozery prądu przemiennego do 38 kV / Automatic circuit reclosers and fault interrupters for alternating current systems up to and including 38 kV, Odłączniki i uziemniki wysokonapięciowe / High voltage alternating current disconnectors and earthing switches","methodology":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:","parameters":[{"name":"udarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV"},{"name":"przemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV","reference":"IEC 62271-111:2019 | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","norm_bases":["IEC 62271-111:2019","PN-EN IEC 62271-102:2018-10","PN-EN IEC 62271-102:2018-10/A1:2023-01","IEC 62271-102:2018+AMD1:2022","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Autoreklozery prądu przemiennego do 38 kV / Automatic circuit reclosers and fault interrupters for alternating current systems up to and including 38 kV, Odłączniki i uziemniki wysokonapięciowe / High voltage alternating current disconnectors and earthing switches Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV IEC 62271-111:2019 | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 Autoreklozery pradu przemiennego do 38 kV / Automatic circuit reclosers and fault interrupters for alternating current systems up to and including 38 kV, Odlaczniki i uziemniki wysokonapieciowe / High voltage alternating current disconnectors and earthing switches Wytrzymalosc elektryczna izolacji napieciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV IEC 62271-111:2019 | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","categories":["construction"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents IEC 62271-111:2019 | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021"},{"_id":"6a7f0bb91995264369d8e259","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Autoreklozery prądu przemiennego do 38 kV / Automatic circuit reclosers and fault interrupters for alternating current systems up to and including 38 kV, Odłączniki i uziemniki wysokonapięciowe / High voltage alternating current disconnectors and earthing switches","methodology":"Graniczne przyrosty temperatury / Temperature rise tests","parameters":[{"name":"Zakres / Range","range":"do 12 kA / up to and including 12 kA"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 12 kA / up to and including 12 kA","reference":"IEC 62271-111:2019 | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","norm_bases":["IEC 62271-111:2019","PN-EN IEC 62271-102:2018-10","PN-EN IEC 62271-102:2018-10/A1:2023-01","IEC 62271-102:2018+AMD1:2022","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Autoreklozery prądu przemiennego do 38 kV / Automatic circuit reclosers and fault interrupters for alternating current systems up to and including 38 kV, Odłączniki i uziemniki wysokonapięciowe / High voltage alternating current disconnectors and earthing switches Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 12 kA / up to and including 12 kA IEC 62271-111:2019 | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 Autoreklozery pradu przemiennego do 38 kV / Automatic circuit reclosers and fault interrupters for alternating current systems up to and including 38 kV, Odlaczniki i uziemniki wysokonapieciowe / High voltage alternating current disconnectors and earthing switches Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 12 kA / up to and including 12 kA IEC 62271-111:2019 | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","categories":["other"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 12 kA / up to and including 12 kA"}],"search_en":"Range Reference documents IEC 62271-111:2019 | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","parameters_zh":[{"name":"范围 / Range","range":"do 12 kA / up to and including 12 kA"}],"search_zh":"范围 / Range IEC 62271-111:2019 | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021"},{"_id":"6a7f0bb91995264369d8e25a","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Autoreklozery prądu przemiennego do 38 kV / Automatic circuit reclosers and fault interrupters for alternating current systems up to and including 38 kV, Odłączniki i uziemniki wysokonapięciowe / High voltage alternating current disconnectors and earthing switches","methodology":"Rezystancja obwodu głównego / Main circuit resistance","parameters":[{"name":"Zakres / Range","range":"od 10-5 Ω / from 10-5 Ω"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Rezystancja obwodu głównego / Main circuit resistance\nZakres / Range od 10-5 Ω / from 10-5 Ω","reference":"IEC 62271-111:2019 | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","norm_bases":["IEC 62271-111:2019","PN-EN IEC 62271-102:2018-10","PN-EN IEC 62271-102:2018-10/A1:2023-01","IEC 62271-102:2018+AMD1:2022","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Autoreklozery prądu przemiennego do 38 kV / Automatic circuit reclosers and fault interrupters for alternating current systems up to and including 38 kV, Odłączniki i uziemniki wysokonapięciowe / High voltage alternating current disconnectors and earthing switches Rezystancja obwodu głównego / Main circuit resistance\nZakres / Range od 10-5 Ω / from 10-5 Ω IEC 62271-111:2019 | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 Autoreklozery pradu przemiennego do 38 kV / Automatic circuit reclosers and fault interrupters for alternating current systems up to and including 38 kV, Odlaczniki i uziemniki wysokonapieciowe / High voltage alternating current disconnectors and earthing switches Rezystancja obwodu glownego / Main circuit resistance\nZakres / Range od 10-5 Ω / from 10-5 Ω IEC 62271-111:2019 | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","categories":["other"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"od 10-5 Ω / from 10-5 Ω"}],"search_en":"Range Reference documents IEC 62271-111:2019 | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","parameters_zh":[{"name":"范围 / Range","range":"od 10-5 Ω / from 10-5 Ω"}],"search_zh":"范围 / Range IEC 62271-111:2019 | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021"},{"_id":"6a7f0bb91995264369d8e25b","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Autoreklozery prądu przemiennego do 38 kV / Automatic circuit reclosers and fault interrupters for alternating current systems up to and including 38 kV, Odłączniki i uziemniki wysokonapięciowe / High voltage alternating current disconnectors and earthing switches","methodology":"Wytrzymałość zwarciowa / Short-circuit tests","parameters":[{"name":"Zakres / Range","range":"do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość zwarciowa / Short-circuit tests\nZakres / Range do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak","reference":"IEC 62271-111:2019 | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","norm_bases":["IEC 62271-111:2019","PN-EN IEC 62271-102:2018-10","PN-EN IEC 62271-102:2018-10/A1:2023-01","IEC 62271-102:2018+AMD1:2022","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Autoreklozery prądu przemiennego do 38 kV / Automatic circuit reclosers and fault interrupters for alternating current systems up to and including 38 kV, Odłączniki i uziemniki wysokonapięciowe / High voltage alternating current disconnectors and earthing switches Wytrzymałość zwarciowa / Short-circuit tests\nZakres / Range do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak IEC 62271-111:2019 | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 Autoreklozery pradu przemiennego do 38 kV / Automatic circuit reclosers and fault interrupters for alternating current systems up to and including 38 kV, Odlaczniki i uziemniki wysokonapieciowe / High voltage alternating current disconnectors and earthing switches Wytrzymalosc zwarciowa / Short-circuit tests\nZakres / Range do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak IEC 62271-111:2019 | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","categories":["other"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak"}],"search_en":"Range Reference documents IEC 62271-111:2019 | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","parameters_zh":[{"name":"范围 / Range","range":"do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak"}],"search_zh":"范围 / Range IEC 62271-111:2019 | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021"},{"_id":"6a7f0bb91995264369d8e25c","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Autoreklozery prądu przemiennego do 38 kV / Automatic circuit reclosers and fault interrupters for alternating current systems up to and including 38 kV, Odłączniki i uziemniki wysokonapięciowe / High voltage alternating current disconnectors and earthing switches","methodology":"Niezawodność działania i trwałość mechaniczna / Mechanical operation. Mechanical endurance","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Niezawodność działania i trwałość mechaniczna / Mechanical operation. Mechanical endurance","reference":"IEC 62271-111:2019 | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","norm_bases":["IEC 62271-111:2019","PN-EN IEC 62271-102:2018-10","PN-EN IEC 62271-102:2018-10/A1:2023-01","IEC 62271-102:2018+AMD1:2022","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Autoreklozery prądu przemiennego do 38 kV / Automatic circuit reclosers and fault interrupters for alternating current systems up to and including 38 kV, Odłączniki i uziemniki wysokonapięciowe / High voltage alternating current disconnectors and earthing switches Niezawodność działania i trwałość mechaniczna / Mechanical operation. Mechanical endurance IEC 62271-111:2019 | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 Autoreklozery pradu przemiennego do 38 kV / Automatic circuit reclosers and fault interrupters for alternating current systems up to and including 38 kV, Odlaczniki i uziemniki wysokonapieciowe / High voltage alternating current disconnectors and earthing switches Niezawodnosc dzialania i trwalosc mechaniczna / Mechanical operation. Mechanical endurance IEC 62271-111:2019 | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","categories":["other"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents IEC 62271-111:2019 | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021"},{"_id":"6a7f0bb91995264369d8e25d","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Autoreklozery prądu przemiennego do 38 kV / Automatic circuit reclosers and fault interrupters for alternating current systems up to and including 38 kV, Odłączniki i uziemniki wysokonapięciowe / High voltage alternating current disconnectors and earthing switches","methodology":"Zdolność łączenia / Making and breaking capacity","parameters":[{"name":"Zakres / Range","range":"do 50 kA / up to and including 50 kA"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Zdolność łączenia / Making and breaking capacity\nZakres / Range do 50 kA / up to and including 50 kA","reference":"IEC 62271-111:2019 | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","norm_bases":["IEC 62271-111:2019","PN-EN IEC 62271-102:2018-10","PN-EN IEC 62271-102:2018-10/A1:2023-01","IEC 62271-102:2018+AMD1:2022","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Autoreklozery prądu przemiennego do 38 kV / Automatic circuit reclosers and fault interrupters for alternating current systems up to and including 38 kV, Odłączniki i uziemniki wysokonapięciowe / High voltage alternating current disconnectors and earthing switches Zdolność łączenia / Making and breaking capacity\nZakres / Range do 50 kA / up to and including 50 kA IEC 62271-111:2019 | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 Autoreklozery pradu przemiennego do 38 kV / Automatic circuit reclosers and fault interrupters for alternating current systems up to and including 38 kV, Odlaczniki i uziemniki wysokonapieciowe / High voltage alternating current disconnectors and earthing switches Zdolnosc laczenia / Making and breaking capacity\nZakres / Range do 50 kA / up to and including 50 kA IEC 62271-111:2019 | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","categories":["other"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 50 kA / up to and including 50 kA"}],"search_en":"Range Reference documents IEC 62271-111:2019 | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","parameters_zh":[{"name":"范围 / Range","range":"do 50 kA / up to and including 50 kA"}],"search_zh":"范围 / Range IEC 62271-111:2019 | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021"},{"_id":"6a7f0bb91995264369d8e25e","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Rozłączniki wysokonapięciowe prądu przemiennego do 52 kV / Switches for rated voltages up to and including 52 kV","methodology":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:","parameters":[{"name":"udarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV"},{"name":"przemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV","reference":"PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","norm_bases":["PN-EN IEC 62271-103:2024-04","IEC 62271-103:2021","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1 :2022-06","IEC 62271-1:2017+AMD1 :2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Rozłączniki wysokonapięciowe prądu przemiennego do 52 kV / Switches for rated voltages up to and including 52 kV Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021 Rozlaczniki wysokonapieciowe pradu przemiennego do 52 kV / Switches for rated voltages up to and including 52 kV Wytrzymalosc elektryczna izolacji napieciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","categories":["construction"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021"},{"_id":"6a7f0bb91995264369d8e25f","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Rozłączniki wysokonapięciowe prądu przemiennego do 52 kV / Switches for rated voltages up to and including 52 kV","methodology":"Rezystancja obwodu głównego / Main circuit resistance","parameters":[{"name":"Zakres / Range","range":"od 10-5 Ω / from 10-5 Ω"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Rezystancja obwodu głównego / Main circuit resistance\nZakres / Range od 10-5 Ω / from 10-5 Ω","reference":"PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","norm_bases":["PN-EN IEC 62271-103:2024-04","IEC 62271-103:2021","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1 :2022-06","IEC 62271-1:2017+AMD1 :2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Rozłączniki wysokonapięciowe prądu przemiennego do 52 kV / Switches for rated voltages up to and including 52 kV Rezystancja obwodu głównego / Main circuit resistance\nZakres / Range od 10-5 Ω / from 10-5 Ω PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021 Rozlaczniki wysokonapieciowe pradu przemiennego do 52 kV / Switches for rated voltages up to and including 52 kV Rezystancja obwodu glownego / Main circuit resistance\nZakres / Range od 10-5 Ω / from 10-5 Ω PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","categories":["other"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"od 10-5 Ω / from 10-5 Ω"}],"search_en":"Range Reference documents PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","parameters_zh":[{"name":"范围 / Range","range":"od 10-5 Ω / from 10-5 Ω"}],"search_zh":"范围 / Range PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021"},{"_id":"6a7f0bb91995264369d8e260","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Rozłączniki wysokonapięciowe prądu przemiennego do 52 kV / Switches for rated voltages up to and including 52 kV","methodology":"Graniczne przyrosty temperatury / Temperature rise tests","parameters":[{"name":"Zakres / Range","range":"do 12 kA / up to and including 12 kA"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 12 kA / up to and including 12 kA","reference":"PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","norm_bases":["PN-EN IEC 62271-103:2024-04","IEC 62271-103:2021","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1 :2022-06","IEC 62271-1:2017+AMD1 :2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Rozłączniki wysokonapięciowe prądu przemiennego do 52 kV / Switches for rated voltages up to and including 52 kV Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 12 kA / up to and including 12 kA PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021 Rozlaczniki wysokonapieciowe pradu przemiennego do 52 kV / Switches for rated voltages up to and including 52 kV Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 12 kA / up to and including 12 kA PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","categories":["other"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 12 kA / up to and including 12 kA"}],"search_en":"Range Reference documents PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","parameters_zh":[{"name":"范围 / Range","range":"do 12 kA / up to and including 12 kA"}],"search_zh":"范围 / Range PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021"},{"_id":"6a7f0bb91995264369d8e261","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Rozłączniki wysokonapięciowe prądu przemiennego do 52 kV / Switches for rated voltages up to and including 52 kV","methodology":"Wytrzymałość zwarciowa / Short-circuit tests","parameters":[{"name":"Zakres / Range","range":"do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość zwarciowa / Short-circuit tests\nZakres / Range do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak","reference":"PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","norm_bases":["PN-EN IEC 62271-103:2024-04","IEC 62271-103:2021","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1 :2022-06","IEC 62271-1:2017+AMD1 :2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Rozłączniki wysokonapięciowe prądu przemiennego do 52 kV / Switches for rated voltages up to and including 52 kV Wytrzymałość zwarciowa / Short-circuit tests\nZakres / Range do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021 Rozlaczniki wysokonapieciowe pradu przemiennego do 52 kV / Switches for rated voltages up to and including 52 kV Wytrzymalosc zwarciowa / Short-circuit tests\nZakres / Range do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","categories":["other"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak"}],"search_en":"Range Reference documents PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","parameters_zh":[{"name":"范围 / Range","range":"do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak"}],"search_zh":"范围 / Range PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021"},{"_id":"6a7f0bb91995264369d8e262","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Rozłączniki wysokonapięciowe prądu przemiennego do 52 kV / Switches for rated voltages up to and including 52 kV","methodology":"Zdolność łączenia / Making and breaking capacity","parameters":[{"name":"Zakres / Range","range":"do 2500 A / up to and including 2500 A"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Zdolność łączenia / Making and breaking capacity\nZakres / Range do 2500 A / up to and including 2500 A","reference":"PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","norm_bases":["PN-EN IEC 62271-103:2024-04","IEC 62271-103:2021","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1 :2022-06","IEC 62271-1:2017+AMD1 :2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Rozłączniki wysokonapięciowe prądu przemiennego do 52 kV / Switches for rated voltages up to and including 52 kV Zdolność łączenia / Making and breaking capacity\nZakres / Range do 2500 A / up to and including 2500 A PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021 Rozlaczniki wysokonapieciowe pradu przemiennego do 52 kV / Switches for rated voltages up to and including 52 kV Zdolnosc laczenia / Making and breaking capacity\nZakres / Range do 2500 A / up to and including 2500 A PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","categories":["other"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 2500 A / up to and including 2500 A"}],"search_en":"Range Reference documents PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","parameters_zh":[{"name":"范围 / Range","range":"do 2500 A / up to and including 2500 A"}],"search_zh":"范围 / Range PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021"},{"_id":"6a7f0bb91995264369d8e263","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Rozłączniki wysokonapięciowe prądu przemiennego do 52 kV / Switches for rated voltages up to and including 52 kV","methodology":"Niezawodność działania i trwałość mechaniczna / Mechanical operation. Mechanical endurance","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Niezawodność działania i trwałość mechaniczna / Mechanical operation. Mechanical endurance","reference":"PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","norm_bases":["PN-EN IEC 62271-103:2024-04","IEC 62271-103:2021","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1 :2022-06","IEC 62271-1:2017+AMD1 :2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Rozłączniki wysokonapięciowe prądu przemiennego do 52 kV / Switches for rated voltages up to and including 52 kV Niezawodność działania i trwałość mechaniczna / Mechanical operation. Mechanical endurance PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021 Rozlaczniki wysokonapieciowe pradu przemiennego do 52 kV / Switches for rated voltages up to and including 52 kV Niezawodnosc dzialania i trwalosc mechaniczna / Mechanical operation. Mechanical endurance PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","categories":["other"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021"},{"_id":"6a7f0bb91995264369d8e264","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Wysokonapięciowe zestawy rozłączników z bezpiecznikami / Alternating current switch-fuse combinations","methodology":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:","parameters":[{"name":"udarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV"},{"name":"przemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV","reference":"PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","norm_bases":["PN-EN IEC 62271-105:2024-04","IEC 62271-105:2021","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1 :2022-06","IEC 62271-1:2017+AMD1 :2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wysokonapięciowe zestawy rozłączników z bezpiecznikami / Alternating current switch-fuse combinations Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021 Wysokonapieciowe zestawy rozlacznikow z bezpiecznikami / Alternating current switch-fuse combinations Wytrzymalosc elektryczna izolacji napieciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","categories":["construction"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021"},{"_id":"6a7f0bb91995264369d8e265","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Wysokonapięciowe zestawy rozłączników z bezpiecznikami / Alternating current switch-fuse combinations","methodology":"Graniczne przyrosty temperatury / Temperature rise tests","parameters":[{"name":"Zakres / Range","range":"do 12 kA / up to and including 12 kA"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 12 kA / up to and including 12 kA","reference":"PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","norm_bases":["PN-EN IEC 62271-105:2024-04","IEC 62271-105:2021","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1 :2022-06","IEC 62271-1:2017+AMD1 :2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wysokonapięciowe zestawy rozłączników z bezpiecznikami / Alternating current switch-fuse combinations Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 12 kA / up to and including 12 kA PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021 Wysokonapieciowe zestawy rozlacznikow z bezpiecznikami / Alternating current switch-fuse combinations Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 12 kA / up to and including 12 kA PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","categories":["other"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 12 kA / up to and including 12 kA"}],"search_en":"Range Reference documents PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","parameters_zh":[{"name":"范围 / Range","range":"do 12 kA / up to and including 12 kA"}],"search_zh":"范围 / Range PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021"},{"_id":"6a7f0bb91995264369d8e266","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Wysokonapięciowe zestawy rozłączników z bezpiecznikami / Alternating current switch-fuse combinations","methodology":"Rezystancja obwodu głównego / Main circuit resistance","parameters":[{"name":"Zakres / Range","range":"od 10-5 Ω / from 10-5 Ω"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Rezystancja obwodu głównego / Main circuit resistance\nZakres / Range od 10-5 Ω / from 10-5 Ω","reference":"PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","norm_bases":["PN-EN IEC 62271-105:2024-04","IEC 62271-105:2021","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1 :2022-06","IEC 62271-1:2017+AMD1 :2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wysokonapięciowe zestawy rozłączników z bezpiecznikami / Alternating current switch-fuse combinations Rezystancja obwodu głównego / Main circuit resistance\nZakres / Range od 10-5 Ω / from 10-5 Ω PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021 Wysokonapieciowe zestawy rozlacznikow z bezpiecznikami / Alternating current switch-fuse combinations Rezystancja obwodu glownego / Main circuit resistance\nZakres / Range od 10-5 Ω / from 10-5 Ω PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","categories":["other"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"od 10-5 Ω / from 10-5 Ω"}],"search_en":"Range Reference documents PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","parameters_zh":[{"name":"范围 / Range","range":"od 10-5 Ω / from 10-5 Ω"}],"search_zh":"范围 / Range PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021"},{"_id":"6a7f0bb91995264369d8e267","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Wysokonapięciowe zestawy rozłączników z bezpiecznikami / Alternating current switch-fuse combinations","methodology":"Wytrzymałość zwarciowa / Short-circuit tests","parameters":[{"name":"Zakres / Range","range":"do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość zwarciowa / Short-circuit tests\nZakres / Range do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak","reference":"PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","norm_bases":["PN-EN IEC 62271-105:2024-04","IEC 62271-105:2021","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1 :2022-06","IEC 62271-1:2017+AMD1 :2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wysokonapięciowe zestawy rozłączników z bezpiecznikami / Alternating current switch-fuse combinations Wytrzymałość zwarciowa / Short-circuit tests\nZakres / Range do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021 Wysokonapieciowe zestawy rozlacznikow z bezpiecznikami / Alternating current switch-fuse combinations Wytrzymalosc zwarciowa / Short-circuit tests\nZakres / Range do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","categories":["other"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak"}],"search_en":"Range Reference documents PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","parameters_zh":[{"name":"范围 / Range","range":"do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak"}],"search_zh":"范围 / Range PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021"},{"_id":"6a7f0bb91995264369d8e268","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Wysokonapięciowe zestawy rozłączników z bezpiecznikami / Alternating current switch-fuse combinations","methodology":"Zdolność łączenia / Making and breaking capacity","parameters":[{"name":"Zakres / Range","range":"do 50 kA / up to and including 50 kA"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Zdolność łączenia / Making and breaking capacity\nZakres / Range do 50 kA / up to and including 50 kA","reference":"PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","norm_bases":["PN-EN IEC 62271-105:2024-04","IEC 62271-105:2021","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1 :2022-06","IEC 62271-1:2017+AMD1 :2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wysokonapięciowe zestawy rozłączników z bezpiecznikami / Alternating current switch-fuse combinations Zdolność łączenia / Making and breaking capacity\nZakres / Range do 50 kA / up to and including 50 kA PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021 Wysokonapieciowe zestawy rozlacznikow z bezpiecznikami / Alternating current switch-fuse combinations Zdolnosc laczenia / Making and breaking capacity\nZakres / Range do 50 kA / up to and including 50 kA PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","categories":["other"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 50 kA / up to and including 50 kA"}],"search_en":"Range Reference documents PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","parameters_zh":[{"name":"范围 / Range","range":"do 50 kA / up to and including 50 kA"}],"search_zh":"范围 / Range PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021"},{"_id":"6a7f0bb91995264369d8e269","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Wysokonapięciowe zestawy rozłączników z bezpiecznikami / Alternating current switch-fuse combinations","methodology":"Działanie mechaniczne / Mechanical operation","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Działanie mechaniczne / Mechanical operation","reference":"PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","norm_bases":["PN-EN IEC 62271-105:2024-04","IEC 62271-105:2021","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1 :2022-06","IEC 62271-1:2017+AMD1 :2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wysokonapięciowe zestawy rozłączników z bezpiecznikami / Alternating current switch-fuse combinations Działanie mechaniczne / Mechanical operation PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021 Wysokonapieciowe zestawy rozlacznikow z bezpiecznikami / Alternating current switch-fuse combinations Dzialanie mechaniczne / Mechanical operation PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","categories":["other"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021"},{"_id":"6a7f0bb91995264369d8e26a","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Styczniki wysokonapięciowe prądu przemiennego / Alternating current high voltage contactors","methodology":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:","parameters":[{"name":"udarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV"},{"name":"przemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV","reference":"PN-EN 62271-106:2021-09 | IEC 62271-106:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","norm_bases":["PN-EN 62271-106:2021-09","IEC 62271-106:2021","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1 :2022-06","IEC 62271-1:2017+AMD1 :2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Styczniki wysokonapięciowe prądu przemiennego / Alternating current high voltage contactors Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV PN-EN 62271-106:2021-09 | IEC 62271-106:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021 Styczniki wysokonapieciowe pradu przemiennego / Alternating current high voltage contactors Wytrzymalosc elektryczna izolacji napieciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV PN-EN 62271-106:2021-09 | IEC 62271-106:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","categories":["construction"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN 62271-106:2021-09 | IEC 62271-106:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021"},{"_id":"6a7f0bb91995264369d8e26b","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Styczniki wysokonapięciowe prądu przemiennego / Alternating current high voltage contactors","methodology":"Graniczne przyrosty temperatury / Temperature rise tests","parameters":[{"name":"Zakres / Range","range":"do 12 kA / up to and including 12 kA"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 12 kA / up to and including 12 kA","reference":"PN-EN 62271-106:2021-09 | IEC 62271-106:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","norm_bases":["PN-EN 62271-106:2021-09","IEC 62271-106:2021","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1 :2022-06","IEC 62271-1:2017+AMD1 :2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Styczniki wysokonapięciowe prądu przemiennego / Alternating current high voltage contactors Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 12 kA / up to and including 12 kA PN-EN 62271-106:2021-09 | IEC 62271-106:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021 Styczniki wysokonapieciowe pradu przemiennego / Alternating current high voltage contactors Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 12 kA / up to and including 12 kA PN-EN 62271-106:2021-09 | IEC 62271-106:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","categories":["other"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 12 kA / up to and including 12 kA"}],"search_en":"Range Reference documents PN-EN 62271-106:2021-09 | IEC 62271-106:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","parameters_zh":[{"name":"范围 / Range","range":"do 12 kA / up to and including 12 kA"}],"search_zh":"范围 / Range PN-EN 62271-106:2021-09 | IEC 62271-106:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021"},{"_id":"6a7f0bb91995264369d8e26c","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Styczniki wysokonapięciowe prądu przemiennego / Alternating current high voltage contactors","methodology":"Rezystancja obwodu głównego / Main circuit resistance","parameters":[{"name":"Zakres / Range","range":"od 10-5 Ω / from 10-5 Ω"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Rezystancja obwodu głównego / Main circuit resistance\nZakres / Range od 10-5 Ω / from 10-5 Ω","reference":"PN-EN 62271-106:2021-09 | IEC 62271-106:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","norm_bases":["PN-EN 62271-106:2021-09","IEC 62271-106:2021","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1 :2022-06","IEC 62271-1:2017+AMD1 :2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Styczniki wysokonapięciowe prądu przemiennego / Alternating current high voltage contactors Rezystancja obwodu głównego / Main circuit resistance\nZakres / Range od 10-5 Ω / from 10-5 Ω PN-EN 62271-106:2021-09 | IEC 62271-106:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021 Styczniki wysokonapieciowe pradu przemiennego / Alternating current high voltage contactors Rezystancja obwodu glownego / Main circuit resistance\nZakres / Range od 10-5 Ω / from 10-5 Ω PN-EN 62271-106:2021-09 | IEC 62271-106:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","categories":["other"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"od 10-5 Ω / from 10-5 Ω"}],"search_en":"Range Reference documents PN-EN 62271-106:2021-09 | IEC 62271-106:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","parameters_zh":[{"name":"范围 / Range","range":"od 10-5 Ω / from 10-5 Ω"}],"search_zh":"范围 / Range PN-EN 62271-106:2021-09 | IEC 62271-106:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021"},{"_id":"6a7f0bb91995264369d8e26d","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Styczniki wysokonapięciowe prądu przemiennego / Alternating current high voltage contactors","methodology":"Wytrzymałość zwarciowa / Short-circuit tests","parameters":[{"name":"Zakres / Range","range":"do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość zwarciowa / Short-circuit tests\nZakres / Range do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak","reference":"PN-EN 62271-106:2021-09 | IEC 62271-106:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","norm_bases":["PN-EN 62271-106:2021-09","IEC 62271-106:2021","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1 :2022-06","IEC 62271-1:2017+AMD1 :2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Styczniki wysokonapięciowe prądu przemiennego / Alternating current high voltage contactors Wytrzymałość zwarciowa / Short-circuit tests\nZakres / Range do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak PN-EN 62271-106:2021-09 | IEC 62271-106:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021 Styczniki wysokonapieciowe pradu przemiennego / Alternating current high voltage contactors Wytrzymalosc zwarciowa / Short-circuit tests\nZakres / Range do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak PN-EN 62271-106:2021-09 | IEC 62271-106:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","categories":["other"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak"}],"search_en":"Range Reference documents PN-EN 62271-106:2021-09 | IEC 62271-106:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021","parameters_zh":[{"name":"范围 / Range","range":"do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak"}],"search_zh":"范围 / Range PN-EN 62271-106:2021-09 | IEC 62271-106:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1 :2022-06 | IEC 62271-1:2017+AMD1 :2021"},{"_id":"6a7f0bb91995264369d8e26e","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Rozdzielnice prądu przemiennego w osłonach metalowych na napięcia znamionowe powyżej 1 kV do 52 kV. / AC metal-enclosed switchgears for rated voltages up to 1 kV and including 52 kV, Rozdzielnice prądu przemiennego w osłonach izolacyjnych na napięcia znamionowe wyższe niż 1 kV do 38 kV / AC insulation-enclosed switchgears for rated voltages up to 1 kV and including 38 kV, Rozdzielnice z izolacją gazową w osłonach metalowych na napięcia znamionowe wyższe niż 52 kV / Gas-insulated metal-enclosed switchgears for rated voltages above 52 kV","methodology":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:","parameters":[{"name":"udarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV"},{"name":"przemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV","reference":"PN-EN 62271-200:2022-02 | PN-EN 62271-200:2022-02/A1:2025-04 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN 62271-201:2014-12 | IEC 62271-201:2014 | PN-EN IEC 62271-203:2023-02 | IEC 62271-203:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","norm_bases":["PN-EN 62271-200:2022-02","PN-EN 62271-200:2022-02/A1:2025-04","IEC 62271-200:2021","IEC 62271-200:2021/AMD1:2024","PN-EN 62271-201:2014-12","IEC 62271-201:2014","PN-EN IEC 62271-203:2023-02","IEC 62271-203:2022","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Rozdzielnice prądu przemiennego w osłonach metalowych na napięcia znamionowe powyżej 1 kV do 52 kV. / AC metal-enclosed switchgears for rated voltages up to 1 kV and including 52 kV, Rozdzielnice prądu przemiennego w osłonach izolacyjnych na napięcia znamionowe wyższe niż 1 kV do 38 kV / AC insulation-enclosed switchgears for rated voltages up to 1 kV and including 38 kV, Rozdzielnice z izolacją gazową w osłonach metalowych na napięcia znamionowe wyższe niż 52 kV / Gas-insulated metal-enclosed switchgears for rated voltages above 52 kV Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV PN-EN 62271-200:2022-02 | PN-EN 62271-200:2022-02/A1:2025-04 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN 62271-201:2014-12 | IEC 62271-201:2014 | PN-EN IEC 62271-203:2023-02 | IEC 62271-203:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 Rozdzielnice pradu przemiennego w oslonach metalowych na napiecia znamionowe powyzej 1 kV do 52 kV. / AC metal-enclosed switchgears for rated voltages up to 1 kV and including 52 kV, Rozdzielnice pradu przemiennego w oslonach izolacyjnych na napiecia znamionowe wyzsze niz 1 kV do 38 kV / AC insulation-enclosed switchgears for rated voltages up to 1 kV and including 38 kV, Rozdzielnice z izolacja gazowa w oslonach metalowych na napiecia znamionowe wyzsze niz 52 kV / Gas-insulated metal-enclosed switchgears for rated voltages above 52 kV Wytrzymalosc elektryczna izolacji napieciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV PN-EN 62271-200:2022-02 | PN-EN 62271-200:2022-02/A1:2025-04 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN 62271-201:2014-12 | IEC 62271-201:2014 | PN-EN IEC 62271-203:2023-02 | IEC 62271-203:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","categories":["materials","construction"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN 62271-200:2022-02 | PN-EN 62271-200:2022-02/A1:2025-04 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN 62271-201:2014-12 | IEC 62271-201:2014 | PN-EN IEC 62271-203:2023-02 | IEC 62271-203:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021"},{"_id":"6a7f0bb91995264369d8e26f","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Rozdzielnice prądu przemiennego w osłonach metalowych na napięcia znamionowe powyżej 1 kV do 52 kV. / AC metal-enclosed switchgears for rated voltages up to 1 kV and including 52 kV, Rozdzielnice prądu przemiennego w osłonach izolacyjnych na napięcia znamionowe wyższe niż 1 kV do 38 kV / AC insulation-enclosed switchgears for rated voltages up to 1 kV and including 38 kV, Rozdzielnice z izolacją gazową w osłonach metalowych na napięcia znamionowe wyższe niż 52 kV / Gas-insulated metal-enclosed switchgears for rated voltages above 52 kV","methodology":"Graniczne przyrosty temperatury / Temperature rise tests","parameters":[{"name":"Zakres / Range","range":"do 12 kA / up to and including 12 kA"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 12 kA / up to and including 12 kA","reference":"PN-EN 62271-200:2022-02 | PN-EN 62271-200:2022-02/A1:2025-04 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN 62271-201:2014-12 | IEC 62271-201:2014 | PN-EN IEC 62271-203:2023-02 | IEC 62271-203:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","norm_bases":["PN-EN 62271-200:2022-02","PN-EN 62271-200:2022-02/A1:2025-04","IEC 62271-200:2021","IEC 62271-200:2021/AMD1:2024","PN-EN 62271-201:2014-12","IEC 62271-201:2014","PN-EN IEC 62271-203:2023-02","IEC 62271-203:2022","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Rozdzielnice prądu przemiennego w osłonach metalowych na napięcia znamionowe powyżej 1 kV do 52 kV. / AC metal-enclosed switchgears for rated voltages up to 1 kV and including 52 kV, Rozdzielnice prądu przemiennego w osłonach izolacyjnych na napięcia znamionowe wyższe niż 1 kV do 38 kV / AC insulation-enclosed switchgears for rated voltages up to 1 kV and including 38 kV, Rozdzielnice z izolacją gazową w osłonach metalowych na napięcia znamionowe wyższe niż 52 kV / Gas-insulated metal-enclosed switchgears for rated voltages above 52 kV Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 12 kA / up to and including 12 kA PN-EN 62271-200:2022-02 | PN-EN 62271-200:2022-02/A1:2025-04 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN 62271-201:2014-12 | IEC 62271-201:2014 | PN-EN IEC 62271-203:2023-02 | IEC 62271-203:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 Rozdzielnice pradu przemiennego w oslonach metalowych na napiecia znamionowe powyzej 1 kV do 52 kV. / AC metal-enclosed switchgears for rated voltages up to 1 kV and including 52 kV, Rozdzielnice pradu przemiennego w oslonach izolacyjnych na napiecia znamionowe wyzsze niz 1 kV do 38 kV / AC insulation-enclosed switchgears for rated voltages up to 1 kV and including 38 kV, Rozdzielnice z izolacja gazowa w oslonach metalowych na napiecia znamionowe wyzsze niz 52 kV / Gas-insulated metal-enclosed switchgears for rated voltages above 52 kV Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 12 kA / up to and including 12 kA PN-EN 62271-200:2022-02 | PN-EN 62271-200:2022-02/A1:2025-04 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN 62271-201:2014-12 | IEC 62271-201:2014 | PN-EN IEC 62271-203:2023-02 | IEC 62271-203:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","categories":["materials","construction"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 12 kA / up to and including 12 kA"}],"search_en":"Range Reference documents PN-EN 62271-200:2022-02 | PN-EN 62271-200:2022-02/A1:2025-04 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN 62271-201:2014-12 | IEC 62271-201:2014 | PN-EN IEC 62271-203:2023-02 | IEC 62271-203:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","parameters_zh":[{"name":"范围 / Range","range":"do 12 kA / up to and including 12 kA"}],"search_zh":"范围 / Range PN-EN 62271-200:2022-02 | PN-EN 62271-200:2022-02/A1:2025-04 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN 62271-201:2014-12 | IEC 62271-201:2014 | PN-EN IEC 62271-203:2023-02 | IEC 62271-203:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021"},{"_id":"6a7f0bb91995264369d8e270","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Rozdzielnice prądu przemiennego w osłonach metalowych na napięcia znamionowe powyżej 1 kV do 52 kV. / AC metal-enclosed switchgears for rated voltages up to 1 kV and including 52 kV, Rozdzielnice prądu przemiennego w osłonach izolacyjnych na napięcia znamionowe wyższe niż 1 kV do 38 kV / AC insulation-enclosed switchgears for rated voltages up to 1 kV and including 38 kV, Rozdzielnice z izolacją gazową w osłonach metalowych na napięcia znamionowe wyższe niż 52 kV / Gas-insulated metal-enclosed switchgears for rated voltages above 52 kV","methodology":"Rezystancja obwodu głównego / Main circuit resistance","parameters":[{"name":"Zakres / Range","range":"od 10-5 Ω / from 10-5 Ω"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Rezystancja obwodu głównego / Main circuit resistance\nZakres / Range od 10-5 Ω / from 10-5 Ω","reference":"PN-EN 62271-200:2022-02 | PN-EN 62271-200:2022-02/A1:2025-04 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN 62271-201:2014-12 | IEC 62271-201:2014 | PN-EN IEC 62271-203:2023-02 | IEC 62271-203:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","norm_bases":["PN-EN 62271-200:2022-02","PN-EN 62271-200:2022-02/A1:2025-04","IEC 62271-200:2021","IEC 62271-200:2021/AMD1:2024","PN-EN 62271-201:2014-12","IEC 62271-201:2014","PN-EN IEC 62271-203:2023-02","IEC 62271-203:2022","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Rozdzielnice prądu przemiennego w osłonach metalowych na napięcia znamionowe powyżej 1 kV do 52 kV. / AC metal-enclosed switchgears for rated voltages up to 1 kV and including 52 kV, Rozdzielnice prądu przemiennego w osłonach izolacyjnych na napięcia znamionowe wyższe niż 1 kV do 38 kV / AC insulation-enclosed switchgears for rated voltages up to 1 kV and including 38 kV, Rozdzielnice z izolacją gazową w osłonach metalowych na napięcia znamionowe wyższe niż 52 kV / Gas-insulated metal-enclosed switchgears for rated voltages above 52 kV Rezystancja obwodu głównego / Main circuit resistance\nZakres / Range od 10-5 Ω / from 10-5 Ω PN-EN 62271-200:2022-02 | PN-EN 62271-200:2022-02/A1:2025-04 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN 62271-201:2014-12 | IEC 62271-201:2014 | PN-EN IEC 62271-203:2023-02 | IEC 62271-203:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 Rozdzielnice pradu przemiennego w oslonach metalowych na napiecia znamionowe powyzej 1 kV do 52 kV. / AC metal-enclosed switchgears for rated voltages up to 1 kV and including 52 kV, Rozdzielnice pradu przemiennego w oslonach izolacyjnych na napiecia znamionowe wyzsze niz 1 kV do 38 kV / AC insulation-enclosed switchgears for rated voltages up to 1 kV and including 38 kV, Rozdzielnice z izolacja gazowa w oslonach metalowych na napiecia znamionowe wyzsze niz 52 kV / Gas-insulated metal-enclosed switchgears for rated voltages above 52 kV Rezystancja obwodu glownego / Main circuit resistance\nZakres / Range od 10-5 Ω / from 10-5 Ω PN-EN 62271-200:2022-02 | PN-EN 62271-200:2022-02/A1:2025-04 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN 62271-201:2014-12 | IEC 62271-201:2014 | PN-EN IEC 62271-203:2023-02 | IEC 62271-203:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","categories":["materials","construction"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"od 10-5 Ω / from 10-5 Ω"}],"search_en":"Range Reference documents PN-EN 62271-200:2022-02 | PN-EN 62271-200:2022-02/A1:2025-04 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN 62271-201:2014-12 | IEC 62271-201:2014 | PN-EN IEC 62271-203:2023-02 | IEC 62271-203:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","parameters_zh":[{"name":"范围 / Range","range":"od 10-5 Ω / from 10-5 Ω"}],"search_zh":"范围 / Range PN-EN 62271-200:2022-02 | PN-EN 62271-200:2022-02/A1:2025-04 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN 62271-201:2014-12 | IEC 62271-201:2014 | PN-EN IEC 62271-203:2023-02 | IEC 62271-203:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021"},{"_id":"6a7f0bb91995264369d8e271","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Rozdzielnice prądu przemiennego w osłonach metalowych na napięcia znamionowe powyżej 1 kV do 52 kV. / AC metal-enclosed switchgears for rated voltages up to 1 kV and including 52 kV, Rozdzielnice prądu przemiennego w osłonach izolacyjnych na napięcia znamionowe wyższe niż 1 kV do 38 kV / AC insulation-enclosed switchgears for rated voltages up to 1 kV and including 38 kV, Rozdzielnice z izolacją gazową w osłonach metalowych na napięcia znamionowe wyższe niż 52 kV / Gas-insulated metal-enclosed switchgears for rated voltages above 52 kV","methodology":"Wytrzymałość zwarciowa / Short-circuit tests","parameters":[{"name":"Zakres / Range","range":"do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość zwarciowa / Short-circuit tests\nZakres / Range do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak","reference":"PN-EN 62271-200:2022-02 | PN-EN 62271-200:2022-02/A1:2025-04 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN 62271-201:2014-12 | IEC 62271-201:2014 | PN-EN IEC 62271-203:2023-02 | IEC 62271-203:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","norm_bases":["PN-EN 62271-200:2022-02","PN-EN 62271-200:2022-02/A1:2025-04","IEC 62271-200:2021","IEC 62271-200:2021/AMD1:2024","PN-EN 62271-201:2014-12","IEC 62271-201:2014","PN-EN IEC 62271-203:2023-02","IEC 62271-203:2022","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Rozdzielnice prądu przemiennego w osłonach metalowych na napięcia znamionowe powyżej 1 kV do 52 kV. / AC metal-enclosed switchgears for rated voltages up to 1 kV and including 52 kV, Rozdzielnice prądu przemiennego w osłonach izolacyjnych na napięcia znamionowe wyższe niż 1 kV do 38 kV / AC insulation-enclosed switchgears for rated voltages up to 1 kV and including 38 kV, Rozdzielnice z izolacją gazową w osłonach metalowych na napięcia znamionowe wyższe niż 52 kV / Gas-insulated metal-enclosed switchgears for rated voltages above 52 kV Wytrzymałość zwarciowa / Short-circuit tests\nZakres / Range do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak PN-EN 62271-200:2022-02 | PN-EN 62271-200:2022-02/A1:2025-04 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN 62271-201:2014-12 | IEC 62271-201:2014 | PN-EN IEC 62271-203:2023-02 | IEC 62271-203:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 Rozdzielnice pradu przemiennego w oslonach metalowych na napiecia znamionowe powyzej 1 kV do 52 kV. / AC metal-enclosed switchgears for rated voltages up to 1 kV and including 52 kV, Rozdzielnice pradu przemiennego w oslonach izolacyjnych na napiecia znamionowe wyzsze niz 1 kV do 38 kV / AC insulation-enclosed switchgears for rated voltages up to 1 kV and including 38 kV, Rozdzielnice z izolacja gazowa w oslonach metalowych na napiecia znamionowe wyzsze niz 52 kV / Gas-insulated metal-enclosed switchgears for rated voltages above 52 kV Wytrzymalosc zwarciowa / Short-circuit tests\nZakres / Range do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak PN-EN 62271-200:2022-02 | PN-EN 62271-200:2022-02/A1:2025-04 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN 62271-201:2014-12 | IEC 62271-201:2014 | PN-EN IEC 62271-203:2023-02 | IEC 62271-203:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","categories":["materials","construction"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak"}],"search_en":"Range Reference documents PN-EN 62271-200:2022-02 | PN-EN 62271-200:2022-02/A1:2025-04 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN 62271-201:2014-12 | IEC 62271-201:2014 | PN-EN IEC 62271-203:2023-02 | IEC 62271-203:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","parameters_zh":[{"name":"范围 / Range","range":"do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak"}],"search_zh":"范围 / Range PN-EN 62271-200:2022-02 | PN-EN 62271-200:2022-02/A1:2025-04 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN 62271-201:2014-12 | IEC 62271-201:2014 | PN-EN IEC 62271-203:2023-02 | IEC 62271-203:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021"},{"_id":"6a7f0bb91995264369d8e272","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Rozdzielnice prądu przemiennego w osłonach metalowych na napięcia znamionowe powyżej 1 kV do 52 kV. / AC metal-enclosed switchgears for rated voltages up to 1 kV and including 52 kV, Rozdzielnice prądu przemiennego w osłonach izolacyjnych na napięcia znamionowe wyższe niż 1 kV do 38 kV / AC insulation-enclosed switchgears for rated voltages up to 1 kV and including 38 kV, Rozdzielnice z izolacją gazową w osłonach metalowych na napięcia znamionowe wyższe niż 52 kV / Gas-insulated metal-enclosed switchgears for rated voltages above 52 kV","methodology":"Zdolność łączenia / Making and breaking capacity","parameters":[{"name":"Zakres / Range","range":"do 2500 A / up to and including 2500 A"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Zdolność łączenia / Making and breaking capacity\nZakres / Range do 2500 A / up to and including 2500 A","reference":"PN-EN 62271-200:2022-02 | PN-EN 62271-200:2022-02/A1:2025-04 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN 62271-201:2014-12 | IEC 62271-201:2014 | PN-EN IEC 62271-203:2023-02 | IEC 62271-203:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","norm_bases":["PN-EN 62271-200:2022-02","PN-EN 62271-200:2022-02/A1:2025-04","IEC 62271-200:2021","IEC 62271-200:2021/AMD1:2024","PN-EN 62271-201:2014-12","IEC 62271-201:2014","PN-EN IEC 62271-203:2023-02","IEC 62271-203:2022","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Rozdzielnice prądu przemiennego w osłonach metalowych na napięcia znamionowe powyżej 1 kV do 52 kV. / AC metal-enclosed switchgears for rated voltages up to 1 kV and including 52 kV, Rozdzielnice prądu przemiennego w osłonach izolacyjnych na napięcia znamionowe wyższe niż 1 kV do 38 kV / AC insulation-enclosed switchgears for rated voltages up to 1 kV and including 38 kV, Rozdzielnice z izolacją gazową w osłonach metalowych na napięcia znamionowe wyższe niż 52 kV / Gas-insulated metal-enclosed switchgears for rated voltages above 52 kV Zdolność łączenia / Making and breaking capacity\nZakres / Range do 2500 A / up to and including 2500 A PN-EN 62271-200:2022-02 | PN-EN 62271-200:2022-02/A1:2025-04 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN 62271-201:2014-12 | IEC 62271-201:2014 | PN-EN IEC 62271-203:2023-02 | IEC 62271-203:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 Rozdzielnice pradu przemiennego w oslonach metalowych na napiecia znamionowe powyzej 1 kV do 52 kV. / AC metal-enclosed switchgears for rated voltages up to 1 kV and including 52 kV, Rozdzielnice pradu przemiennego w oslonach izolacyjnych na napiecia znamionowe wyzsze niz 1 kV do 38 kV / AC insulation-enclosed switchgears for rated voltages up to 1 kV and including 38 kV, Rozdzielnice z izolacja gazowa w oslonach metalowych na napiecia znamionowe wyzsze niz 52 kV / Gas-insulated metal-enclosed switchgears for rated voltages above 52 kV Zdolnosc laczenia / Making and breaking capacity\nZakres / Range do 2500 A / up to and including 2500 A PN-EN 62271-200:2022-02 | PN-EN 62271-200:2022-02/A1:2025-04 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN 62271-201:2014-12 | IEC 62271-201:2014 | PN-EN IEC 62271-203:2023-02 | IEC 62271-203:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","categories":["materials","construction"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 2500 A / up to and including 2500 A"}],"search_en":"Range Reference documents PN-EN 62271-200:2022-02 | PN-EN 62271-200:2022-02/A1:2025-04 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN 62271-201:2014-12 | IEC 62271-201:2014 | PN-EN IEC 62271-203:2023-02 | IEC 62271-203:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","parameters_zh":[{"name":"范围 / Range","range":"do 2500 A / up to and including 2500 A"}],"search_zh":"范围 / Range PN-EN 62271-200:2022-02 | PN-EN 62271-200:2022-02/A1:2025-04 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN 62271-201:2014-12 | IEC 62271-201:2014 | PN-EN IEC 62271-203:2023-02 | IEC 62271-203:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021"},{"_id":"6a7f0bb91995264369d8e273","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Rozdzielnice prądu przemiennego w osłonach metalowych na napięcia znamionowe powyżej 1 kV do 52 kV. / AC metal-enclosed switchgears for rated voltages up to 1 kV and including 52 kV, Rozdzielnice prądu przemiennego w osłonach izolacyjnych na napięcia znamionowe wyższe niż 1 kV do 38 kV / AC insulation-enclosed switchgears for rated voltages up to 1 kV and including 38 kV, Rozdzielnice z izolacją gazową w osłonach metalowych na napięcia znamionowe wyższe niż 52 kV / Gas-insulated metal-enclosed switchgears for rated voltages above 52 kV","methodology":"Działanie mechaniczne / Mechanical operation","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Działanie mechaniczne / Mechanical operation","reference":"PN-EN 62271-200:2022-02 | PN-EN 62271-200:2022-02/A1:2025-04 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN 62271-201:2014-12 | IEC 62271-201:2014 | PN-EN IEC 62271-203:2023-02 | IEC 62271-203:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","norm_bases":["PN-EN 62271-200:2022-02","PN-EN 62271-200:2022-02/A1:2025-04","IEC 62271-200:2021","IEC 62271-200:2021/AMD1:2024","PN-EN 62271-201:2014-12","IEC 62271-201:2014","PN-EN IEC 62271-203:2023-02","IEC 62271-203:2022","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Rozdzielnice prądu przemiennego w osłonach metalowych na napięcia znamionowe powyżej 1 kV do 52 kV. / AC metal-enclosed switchgears for rated voltages up to 1 kV and including 52 kV, Rozdzielnice prądu przemiennego w osłonach izolacyjnych na napięcia znamionowe wyższe niż 1 kV do 38 kV / AC insulation-enclosed switchgears for rated voltages up to 1 kV and including 38 kV, Rozdzielnice z izolacją gazową w osłonach metalowych na napięcia znamionowe wyższe niż 52 kV / Gas-insulated metal-enclosed switchgears for rated voltages above 52 kV Działanie mechaniczne / Mechanical operation PN-EN 62271-200:2022-02 | PN-EN 62271-200:2022-02/A1:2025-04 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN 62271-201:2014-12 | IEC 62271-201:2014 | PN-EN IEC 62271-203:2023-02 | IEC 62271-203:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 Rozdzielnice pradu przemiennego w oslonach metalowych na napiecia znamionowe powyzej 1 kV do 52 kV. / AC metal-enclosed switchgears for rated voltages up to 1 kV and including 52 kV, Rozdzielnice pradu przemiennego w oslonach izolacyjnych na napiecia znamionowe wyzsze niz 1 kV do 38 kV / AC insulation-enclosed switchgears for rated voltages up to 1 kV and including 38 kV, Rozdzielnice z izolacja gazowa w oslonach metalowych na napiecia znamionowe wyzsze niz 52 kV / Gas-insulated metal-enclosed switchgears for rated voltages above 52 kV Dzialanie mechaniczne / Mechanical operation PN-EN 62271-200:2022-02 | PN-EN 62271-200:2022-02/A1:2025-04 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN 62271-201:2014-12 | IEC 62271-201:2014 | PN-EN IEC 62271-203:2023-02 | IEC 62271-203:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","categories":["materials","construction"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN 62271-200:2022-02 | PN-EN 62271-200:2022-02/A1:2025-04 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN 62271-201:2014-12 | IEC 62271-201:2014 | PN-EN IEC 62271-203:2023-02 | IEC 62271-203:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021"},{"_id":"6a7f0bb91995264369d8e274","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Rozdzielnice prądu przemiennego w osłonach metalowych na napięcia znamionowe powyżej 1 kV do 52 kV. / AC metal-enclosed switchgears for rated voltages up to 1 kV and including 52 kV, Rozdzielnice prądu przemiennego w osłonach izolacyjnych na napięcia znamionowe wyższe niż 1 kV do 38 kV / AC insulation-enclosed switchgears for rated voltages up to 1 kV and including 38 kV, Rozdzielnice z izolacją gazową w osłonach metalowych na napięcia znamionowe wyższe niż 52 kV / Gas-insulated metal-enclosed switchgears for rated voltages above 52 kV","methodology":"Odporność na działanie łuku elektrycznego / Internal arc fault tests","parameters":[{"name":"Zakres / Range","range":"do 50 kA / up to and including 50 kA"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Odporność na działanie łuku elektrycznego / Internal arc fault tests\nZakres / Range do 50 kA / up to and including 50 kA","reference":"PN-EN 62271-200:2022-02 | PN-EN 62271-200:2022-02/A1:2025-04 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN 62271-201:2014-12 | IEC 62271-201:2014 | PN-EN IEC 62271-203:2023-02 | IEC 62271-203:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","norm_bases":["PN-EN 62271-200:2022-02","PN-EN 62271-200:2022-02/A1:2025-04","IEC 62271-200:2021","IEC 62271-200:2021/AMD1:2024","PN-EN 62271-201:2014-12","IEC 62271-201:2014","PN-EN IEC 62271-203:2023-02","IEC 62271-203:2022","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Rozdzielnice prądu przemiennego w osłonach metalowych na napięcia znamionowe powyżej 1 kV do 52 kV. / AC metal-enclosed switchgears for rated voltages up to 1 kV and including 52 kV, Rozdzielnice prądu przemiennego w osłonach izolacyjnych na napięcia znamionowe wyższe niż 1 kV do 38 kV / AC insulation-enclosed switchgears for rated voltages up to 1 kV and including 38 kV, Rozdzielnice z izolacją gazową w osłonach metalowych na napięcia znamionowe wyższe niż 52 kV / Gas-insulated metal-enclosed switchgears for rated voltages above 52 kV Odporność na działanie łuku elektrycznego / Internal arc fault tests\nZakres / Range do 50 kA / up to and including 50 kA PN-EN 62271-200:2022-02 | PN-EN 62271-200:2022-02/A1:2025-04 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN 62271-201:2014-12 | IEC 62271-201:2014 | PN-EN IEC 62271-203:2023-02 | IEC 62271-203:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 Rozdzielnice pradu przemiennego w oslonach metalowych na napiecia znamionowe powyzej 1 kV do 52 kV. / AC metal-enclosed switchgears for rated voltages up to 1 kV and including 52 kV, Rozdzielnice pradu przemiennego w oslonach izolacyjnych na napiecia znamionowe wyzsze niz 1 kV do 38 kV / AC insulation-enclosed switchgears for rated voltages up to 1 kV and including 38 kV, Rozdzielnice z izolacja gazowa w oslonach metalowych na napiecia znamionowe wyzsze niz 52 kV / Gas-insulated metal-enclosed switchgears for rated voltages above 52 kV Odpornosc na dzialanie luku elektrycznego / Internal arc fault tests\nZakres / Range do 50 kA / up to and including 50 kA PN-EN 62271-200:2022-02 | PN-EN 62271-200:2022-02/A1:2025-04 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN 62271-201:2014-12 | IEC 62271-201:2014 | PN-EN IEC 62271-203:2023-02 | IEC 62271-203:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","categories":["materials","construction"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 50 kA / up to and including 50 kA"}],"search_en":"Range Reference documents PN-EN 62271-200:2022-02 | PN-EN 62271-200:2022-02/A1:2025-04 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN 62271-201:2014-12 | IEC 62271-201:2014 | PN-EN IEC 62271-203:2023-02 | IEC 62271-203:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","parameters_zh":[{"name":"范围 / Range","range":"do 50 kA / up to and including 50 kA"}],"search_zh":"范围 / Range PN-EN 62271-200:2022-02 | PN-EN 62271-200:2022-02/A1:2025-04 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN 62271-201:2014-12 | IEC 62271-201:2014 | PN-EN IEC 62271-203:2023-02 | IEC 62271-203:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021"},{"_id":"6a7f0bb91995264369d8e275","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Izolatory wysokiego i niskiego napięcia / Low voltage and high voltage insulators","methodology":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:","parameters":[{"name":"udarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV"},{"name":"przemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV","reference":"PN-EN 60137:2018-02 | PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04 | PN-EN 61109:2010 | PN-E-91062-1:1998 | PN-E-91062-2:1998","norm_bases":["PN-EN 60137:2018-02","PN-EN 60383-1:2005","PN-EN 60383-1:2024-04","PN-EN 61109:2010","PN-E-91062-1:1998","PN-E-91062-2:1998"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory wysokiego i niskiego napięcia / Low voltage and high voltage insulators Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV PN-EN 60137:2018-02 | PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04 | PN-EN 61109:2010 | PN-E-91062-1:1998 | PN-E-91062-2:1998 Izolatory wysokiego i niskiego napiecia / Low voltage and high voltage insulators Wytrzymalosc elektryczna izolacji napieciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV PN-EN 60137:2018-02 | PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04 | PN-EN 61109:2010 | PN-E-91062-1:1998 | PN-E-91062-2:1998","categories":["construction"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN 60137:2018-02 | PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04 | PN-EN 61109:2010 | PN-E-91062-1:1998 | PN-E-91062-2:1998"},{"_id":"6a7f0bb91995264369d8e276","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Izolatory wysokiego i niskiego napięcia / Low voltage and high voltage insulators","methodology":"Graniczne przyrosty temperatury / Temperature rise tests","parameters":[{"name":"Zakres / Range","range":"do 12 kA / up to and including 12 kA"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 12 kA / up to and including 12 kA","reference":"PN-EN 60137:2018-02 | PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04 | PN-EN 61109:2010 | PN-E-91062-1:1998 | PN-E-91062-2:1998","norm_bases":["PN-EN 60137:2018-02","PN-EN 60383-1:2005","PN-EN 60383-1:2024-04","PN-EN 61109:2010","PN-E-91062-1:1998","PN-E-91062-2:1998"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory wysokiego i niskiego napięcia / Low voltage and high voltage insulators Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 12 kA / up to and including 12 kA PN-EN 60137:2018-02 | PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04 | PN-EN 61109:2010 | PN-E-91062-1:1998 | PN-E-91062-2:1998 Izolatory wysokiego i niskiego napiecia / Low voltage and high voltage insulators Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 12 kA / up to and including 12 kA PN-EN 60137:2018-02 | PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04 | PN-EN 61109:2010 | PN-E-91062-1:1998 | PN-E-91062-2:1998","categories":["other"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 12 kA / up to and including 12 kA"}],"search_en":"Range Reference documents PN-EN 60137:2018-02 | PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04 | PN-EN 61109:2010 | PN-E-91062-1:1998 | PN-E-91062-2:1998","parameters_zh":[{"name":"范围 / Range","range":"do 12 kA / up to and including 12 kA"}],"search_zh":"范围 / Range PN-EN 60137:2018-02 | PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04 | PN-EN 61109:2010 | PN-E-91062-1:1998 | PN-E-91062-2:1998"},{"_id":"6a7f0bb91995264369d8e277","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Izolatory wysokiego i niskiego napięcia / Low voltage and high voltage insulators","methodology":"Wytrzymałość zwarciowa / Short-circuit tests","parameters":[{"name":"Zakres / Range","range":"do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość zwarciowa / Short-circuit tests\nZakres / Range do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak","reference":"PN-EN 60137:2018-02 | PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04 | PN-EN 61109:2010 | PN-E-91062-1:1998 | PN-E-91062-2:1998","norm_bases":["PN-EN 60137:2018-02","PN-EN 60383-1:2005","PN-EN 60383-1:2024-04","PN-EN 61109:2010","PN-E-91062-1:1998","PN-E-91062-2:1998"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolatory wysokiego i niskiego napięcia / Low voltage and high voltage insulators Wytrzymałość zwarciowa / Short-circuit tests\nZakres / Range do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak PN-EN 60137:2018-02 | PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04 | PN-EN 61109:2010 | PN-E-91062-1:1998 | PN-E-91062-2:1998 Izolatory wysokiego i niskiego napiecia / Low voltage and high voltage insulators Wytrzymalosc zwarciowa / Short-circuit tests\nZakres / Range do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak PN-EN 60137:2018-02 | PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04 | PN-EN 61109:2010 | PN-E-91062-1:1998 | PN-E-91062-2:1998","categories":["other"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak"}],"search_en":"Range Reference documents PN-EN 60137:2018-02 | PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04 | PN-EN 61109:2010 | PN-E-91062-1:1998 | PN-E-91062-2:1998","parameters_zh":[{"name":"范围 / Range","range":"do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak"}],"search_zh":"范围 / Range PN-EN 60137:2018-02 | PN-EN 60383-1:2005 | PN-EN 60383-1:2024-04 | PN-EN 61109:2010 | PN-E-91062-1:1998 | PN-E-91062-2:1998"},{"_id":"6a7f0bb91995264369d8e278","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Stacje transformatorowe wysokiego napięcia na niskie napięcie / High-voltage/low-voltage prefabricated substations","methodology":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:","parameters":[{"name":"udarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV"},{"name":"przemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV","reference":"PN-EN IEC 62271-202:2023-02 | IEC 62271-202:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 | PN-G-42021:1997","norm_bases":["PN-EN IEC 62271-202:2023-02","IEC 62271-202:2022","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021","PN-G-42021:1997"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stacje transformatorowe wysokiego napięcia na niskie napięcie / High-voltage/low-voltage prefabricated substations Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV PN-EN IEC 62271-202:2023-02 | IEC 62271-202:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 | PN-G-42021:1997 Stacje transformatorowe wysokiego napiecia na niskie napiecie / High-voltage/low-voltage prefabricated substations Wytrzymalosc elektryczna izolacji napieciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV PN-EN IEC 62271-202:2023-02 | IEC 62271-202:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 | PN-G-42021:1997","categories":["construction"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN IEC 62271-202:2023-02 | IEC 62271-202:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 | PN-G-42021:1997"},{"_id":"6a7f0bb91995264369d8e279","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Stacje transformatorowe wysokiego napięcia na niskie napięcie / High-voltage/low-voltage prefabricated substations","methodology":"Graniczne przyrosty temperatury / Temperature rise tests","parameters":[{"name":"Zakres / Range","range":"do 12 kA / up to and including 12 kA"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 12 kA / up to and including 12 kA","reference":"PN-EN IEC 62271-202:2023-02 | IEC 62271-202:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 | PN-G-42021:1997","norm_bases":["PN-EN IEC 62271-202:2023-02","IEC 62271-202:2022","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021","PN-G-42021:1997"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stacje transformatorowe wysokiego napięcia na niskie napięcie / High-voltage/low-voltage prefabricated substations Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 12 kA / up to and including 12 kA PN-EN IEC 62271-202:2023-02 | IEC 62271-202:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 | PN-G-42021:1997 Stacje transformatorowe wysokiego napiecia na niskie napiecie / High-voltage/low-voltage prefabricated substations Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 12 kA / up to and including 12 kA PN-EN IEC 62271-202:2023-02 | IEC 62271-202:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 | PN-G-42021:1997","categories":["other"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 12 kA / up to and including 12 kA"}],"search_en":"Range Reference documents PN-EN IEC 62271-202:2023-02 | IEC 62271-202:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 | PN-G-42021:1997","parameters_zh":[{"name":"范围 / Range","range":"do 12 kA / up to and including 12 kA"}],"search_zh":"范围 / Range PN-EN IEC 62271-202:2023-02 | IEC 62271-202:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 | PN-G-42021:1997"},{"_id":"6a7f0bb91995264369d8e27a","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Stacje transformatorowe wysokiego napięcia na niskie napięcie / High-voltage/low-voltage prefabricated substations","methodology":"Wytrzymałość zwarciowa / Short-circuit tests","parameters":[{"name":"Zakres / Range","range":"do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość zwarciowa / Short-circuit tests\nZakres / Range do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak","reference":"PN-EN IEC 62271-202:2023-02 | IEC 62271-202:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 | PN-G-42021:1997","norm_bases":["PN-EN IEC 62271-202:2023-02","IEC 62271-202:2022","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021","PN-G-42021:1997"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stacje transformatorowe wysokiego napięcia na niskie napięcie / High-voltage/low-voltage prefabricated substations Wytrzymałość zwarciowa / Short-circuit tests\nZakres / Range do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak PN-EN IEC 62271-202:2023-02 | IEC 62271-202:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 | PN-G-42021:1997 Stacje transformatorowe wysokiego napiecia na niskie napiecie / High-voltage/low-voltage prefabricated substations Wytrzymalosc zwarciowa / Short-circuit tests\nZakres / Range do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak PN-EN IEC 62271-202:2023-02 | IEC 62271-202:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 | PN-G-42021:1997","categories":["other"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak"}],"search_en":"Range Reference documents PN-EN IEC 62271-202:2023-02 | IEC 62271-202:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 | PN-G-42021:1997","parameters_zh":[{"name":"范围 / Range","range":"do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak"}],"search_zh":"范围 / Range PN-EN IEC 62271-202:2023-02 | IEC 62271-202:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 | PN-G-42021:1997"},{"_id":"6a7f0bb91995264369d8e27b","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Stacje transformatorowe wysokiego napięcia na niskie napięcie / High-voltage/low-voltage prefabricated substations","methodology":"Odporność na działanie łuku elektrycznego / Internal arc fault tests","parameters":[{"name":"Zakres / Range","range":"do 50 kA / up to and including 50 kA"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Odporność na działanie łuku elektrycznego / Internal arc fault tests\nZakres / Range do 50 kA / up to and including 50 kA","reference":"PN-EN IEC 62271-202:2023-02 | IEC 62271-202:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 | PN-G-42021:1997","norm_bases":["PN-EN IEC 62271-202:2023-02","IEC 62271-202:2022","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021","PN-G-42021:1997"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stacje transformatorowe wysokiego napięcia na niskie napięcie / High-voltage/low-voltage prefabricated substations Odporność na działanie łuku elektrycznego / Internal arc fault tests\nZakres / Range do 50 kA / up to and including 50 kA PN-EN IEC 62271-202:2023-02 | IEC 62271-202:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 | PN-G-42021:1997 Stacje transformatorowe wysokiego napiecia na niskie napiecie / High-voltage/low-voltage prefabricated substations Odpornosc na dzialanie luku elektrycznego / Internal arc fault tests\nZakres / Range do 50 kA / up to and including 50 kA PN-EN IEC 62271-202:2023-02 | IEC 62271-202:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 | PN-G-42021:1997","categories":["other"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 50 kA / up to and including 50 kA"}],"search_en":"Range Reference documents PN-EN IEC 62271-202:2023-02 | IEC 62271-202:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 | PN-G-42021:1997","parameters_zh":[{"name":"范围 / Range","range":"do 50 kA / up to and including 50 kA"}],"search_zh":"范围 / Range PN-EN IEC 62271-202:2023-02 | IEC 62271-202:2022 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 | PN-G-42021:1997"},{"_id":"6a7f0bb91995264369d8e27c","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Transformatory i dławiki / Reactors and transformers","methodology":"Rezystancja uzwojeń / Resistance of windings","parameters":[{"name":"Zakres / Range","range":"od 10-4 Ω / from 10-4 Ω"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Rezystancja uzwojeń / Resistance of windings\nZakres / Range od 10-4 Ω / from 10-4 Ω","reference":"PN-EN 60076-1:2011 | IEC 60076-1:2011 | PN-EN 60076-2:2011 | IEC 60076-2:2011 | PN-EN 60076-3:2014-02 | PN-EN 60076-3:2014-02/A1:2018-09 | IEC 60076-3:2013+AMD1:2018 CSV | PN-EN 60076-4:2004 | IEC 60076-4:2002 | PN-EN 60076-5:2009 | IEC 60076-5:2006 | PN-EN 60076-6:2008 | IEC 60076-6:2007 | PN-EN IEC 60076-11:2019-01 | IEC 60076-11:2018","norm_bases":["PN-EN 60076-1:2011","IEC 60076-1:2011","PN-EN 60076-2:2011","IEC 60076-2:2011","PN-EN 60076-3:2014-02","PN-EN 60076-3:2014-02/A1:2018-09","IEC 60076-3:2013+AMD1:2018 CSV","PN-EN 60076-4:2004","IEC 60076-4:2002","PN-EN 60076-5:2009","IEC 60076-5:2006","PN-EN 60076-6:2008","IEC 60076-6:2007","PN-EN IEC 60076-11:2019-01","IEC 60076-11:2018"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Transformatory i dławiki / Reactors and transformers Rezystancja uzwojeń / Resistance of windings\nZakres / Range od 10-4 Ω / from 10-4 Ω PN-EN 60076-1:2011 | IEC 60076-1:2011 | PN-EN 60076-2:2011 | IEC 60076-2:2011 | PN-EN 60076-3:2014-02 | PN-EN 60076-3:2014-02/A1:2018-09 | IEC 60076-3:2013+AMD1:2018 CSV | PN-EN 60076-4:2004 | IEC 60076-4:2002 | PN-EN 60076-5:2009 | IEC 60076-5:2006 | PN-EN 60076-6:2008 | IEC 60076-6:2007 | PN-EN IEC 60076-11:2019-01 | IEC 60076-11:2018 Transformatory i dlawiki / Reactors and transformers Rezystancja uzwojen / Resistance of windings\nZakres / Range od 10-4 Ω / from 10-4 Ω PN-EN 60076-1:2011 | IEC 60076-1:2011 | PN-EN 60076-2:2011 | IEC 60076-2:2011 | PN-EN 60076-3:2014-02 | PN-EN 60076-3:2014-02/A1:2018-09 | IEC 60076-3:2013+AMD1:2018 CSV | PN-EN 60076-4:2004 | IEC 60076-4:2002 | PN-EN 60076-5:2009 | IEC 60076-5:2006 | PN-EN 60076-6:2008 | IEC 60076-6:2007 | PN-EN IEC 60076-11:2019-01 | IEC 60076-11:2018","categories":["other"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"od 10-4 Ω / from 10-4 Ω"}],"search_en":"Range Reference documents PN-EN 60076-1:2011 | IEC 60076-1:2011 | PN-EN 60076-2:2011 | IEC 60076-2:2011 | PN-EN 60076-3:2014-02 | PN-EN 60076-3:2014-02/A1:2018-09 | IEC 60076-3:2013+AMD1:2018 CSV | PN-EN 60076-4:2004 | IEC 60076-4:2002 | PN-EN 60076-5:2009 | IEC 60076-5:2006 | PN-EN 60076-6:2008 | IEC 60076-6:2007 | PN-EN IEC 60076-11:2019-01 | IEC 60076-11:2018","parameters_zh":[{"name":"范围 / Range","range":"od 10-4 Ω / from 10-4 Ω"}],"search_zh":"范围 / Range PN-EN 60076-1:2011 | IEC 60076-1:2011 | PN-EN 60076-2:2011 | IEC 60076-2:2011 | PN-EN 60076-3:2014-02 | PN-EN 60076-3:2014-02/A1:2018-09 | IEC 60076-3:2013+AMD1:2018 CSV | PN-EN 60076-4:2004 | IEC 60076-4:2002 | PN-EN 60076-5:2009 | IEC 60076-5:2006 | PN-EN 60076-6:2008 | IEC 60076-6:2007 | PN-EN IEC 60076-11:2019-01 | IEC 60076-11:2018"},{"_id":"6a7f0bb91995264369d8e27d","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Transformatory i dławiki / Reactors and transformers","methodology":"Graniczne przyrosty temperatury / Temperature rise tests","parameters":[{"name":"Zakres / Range","range":"do 4 kA / up to and including 4 kA"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 4 kA / up to and including 4 kA","reference":"PN-EN 60076-1:2011 | IEC 60076-1:2011 | PN-EN 60076-2:2011 | IEC 60076-2:2011 | PN-EN 60076-3:2014-02 | PN-EN 60076-3:2014-02/A1:2018-09 | IEC 60076-3:2013+AMD1:2018 CSV | PN-EN 60076-4:2004 | IEC 60076-4:2002 | PN-EN 60076-5:2009 | IEC 60076-5:2006 | PN-EN 60076-6:2008 | IEC 60076-6:2007 | PN-EN IEC 60076-11:2019-01 | IEC 60076-11:2018","norm_bases":["PN-EN 60076-1:2011","IEC 60076-1:2011","PN-EN 60076-2:2011","IEC 60076-2:2011","PN-EN 60076-3:2014-02","PN-EN 60076-3:2014-02/A1:2018-09","IEC 60076-3:2013+AMD1:2018 CSV","PN-EN 60076-4:2004","IEC 60076-4:2002","PN-EN 60076-5:2009","IEC 60076-5:2006","PN-EN 60076-6:2008","IEC 60076-6:2007","PN-EN IEC 60076-11:2019-01","IEC 60076-11:2018"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Transformatory i dławiki / Reactors and transformers Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 4 kA / up to and including 4 kA PN-EN 60076-1:2011 | IEC 60076-1:2011 | PN-EN 60076-2:2011 | IEC 60076-2:2011 | PN-EN 60076-3:2014-02 | PN-EN 60076-3:2014-02/A1:2018-09 | IEC 60076-3:2013+AMD1:2018 CSV | PN-EN 60076-4:2004 | IEC 60076-4:2002 | PN-EN 60076-5:2009 | IEC 60076-5:2006 | PN-EN 60076-6:2008 | IEC 60076-6:2007 | PN-EN IEC 60076-11:2019-01 | IEC 60076-11:2018 Transformatory i dlawiki / Reactors and transformers Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 4 kA / up to and including 4 kA PN-EN 60076-1:2011 | IEC 60076-1:2011 | PN-EN 60076-2:2011 | IEC 60076-2:2011 | PN-EN 60076-3:2014-02 | PN-EN 60076-3:2014-02/A1:2018-09 | IEC 60076-3:2013+AMD1:2018 CSV | PN-EN 60076-4:2004 | IEC 60076-4:2002 | PN-EN 60076-5:2009 | IEC 60076-5:2006 | PN-EN 60076-6:2008 | IEC 60076-6:2007 | PN-EN IEC 60076-11:2019-01 | IEC 60076-11:2018","categories":["other"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 4 kA / up to and including 4 kA"}],"search_en":"Range Reference documents PN-EN 60076-1:2011 | IEC 60076-1:2011 | PN-EN 60076-2:2011 | IEC 60076-2:2011 | PN-EN 60076-3:2014-02 | PN-EN 60076-3:2014-02/A1:2018-09 | IEC 60076-3:2013+AMD1:2018 CSV | PN-EN 60076-4:2004 | IEC 60076-4:2002 | PN-EN 60076-5:2009 | IEC 60076-5:2006 | PN-EN 60076-6:2008 | IEC 60076-6:2007 | PN-EN IEC 60076-11:2019-01 | IEC 60076-11:2018","parameters_zh":[{"name":"范围 / Range","range":"do 4 kA / up to and including 4 kA"}],"search_zh":"范围 / Range PN-EN 60076-1:2011 | IEC 60076-1:2011 | PN-EN 60076-2:2011 | IEC 60076-2:2011 | PN-EN 60076-3:2014-02 | PN-EN 60076-3:2014-02/A1:2018-09 | IEC 60076-3:2013+AMD1:2018 CSV | PN-EN 60076-4:2004 | IEC 60076-4:2002 | PN-EN 60076-5:2009 | IEC 60076-5:2006 | PN-EN 60076-6:2008 | IEC 60076-6:2007 | PN-EN IEC 60076-11:2019-01 | IEC 60076-11:2018"},{"_id":"6a7f0bb91995264369d8e27e","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Transformatory i dławiki / Reactors and transformers","methodology":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:","parameters":[{"name":"udarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV"},{"name":"udarowym łączeniowym do Up=900 kV / switching impulse up to Up=900 kV"},{"name":"przemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nudarowym łączeniowym do Up=900 kV / switching impulse up to Up=900 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV","reference":"PN-EN 60076-1:2011 | IEC 60076-1:2011 | PN-EN 60076-2:2011 | IEC 60076-2:2011 | PN-EN 60076-3:2014-02 | PN-EN 60076-3:2014-02/A1:2018-09 | IEC 60076-3:2013+AMD1:2018 CSV | PN-EN 60076-4:2004 | IEC 60076-4:2002 | PN-EN 60076-5:2009 | IEC 60076-5:2006 | PN-EN 60076-6:2008 | IEC 60076-6:2007 | PN-EN IEC 60076-11:2019-01 | IEC 60076-11:2018","norm_bases":["PN-EN 60076-1:2011","IEC 60076-1:2011","PN-EN 60076-2:2011","IEC 60076-2:2011","PN-EN 60076-3:2014-02","PN-EN 60076-3:2014-02/A1:2018-09","IEC 60076-3:2013+AMD1:2018 CSV","PN-EN 60076-4:2004","IEC 60076-4:2002","PN-EN 60076-5:2009","IEC 60076-5:2006","PN-EN 60076-6:2008","IEC 60076-6:2007","PN-EN IEC 60076-11:2019-01","IEC 60076-11:2018"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Transformatory i dławiki / Reactors and transformers Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nudarowym łączeniowym do Up=900 kV / switching impulse up to Up=900 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV PN-EN 60076-1:2011 | IEC 60076-1:2011 | PN-EN 60076-2:2011 | IEC 60076-2:2011 | PN-EN 60076-3:2014-02 | PN-EN 60076-3:2014-02/A1:2018-09 | IEC 60076-3:2013+AMD1:2018 CSV | PN-EN 60076-4:2004 | IEC 60076-4:2002 | PN-EN 60076-5:2009 | IEC 60076-5:2006 | PN-EN 60076-6:2008 | IEC 60076-6:2007 | PN-EN IEC 60076-11:2019-01 | IEC 60076-11:2018 Transformatory i dlawiki / Reactors and transformers Wytrzymalosc elektryczna izolacji napieciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nudarowym laczeniowym do Up=900 kV / switching impulse up to Up=900 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV PN-EN 60076-1:2011 | IEC 60076-1:2011 | PN-EN 60076-2:2011 | IEC 60076-2:2011 | PN-EN 60076-3:2014-02 | PN-EN 60076-3:2014-02/A1:2018-09 | IEC 60076-3:2013+AMD1:2018 CSV | PN-EN 60076-4:2004 | IEC 60076-4:2002 | PN-EN 60076-5:2009 | IEC 60076-5:2006 | PN-EN 60076-6:2008 | IEC 60076-6:2007 | PN-EN IEC 60076-11:2019-01 | IEC 60076-11:2018","categories":["construction"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN 60076-1:2011 | IEC 60076-1:2011 | PN-EN 60076-2:2011 | IEC 60076-2:2011 | PN-EN 60076-3:2014-02 | PN-EN 60076-3:2014-02/A1:2018-09 | IEC 60076-3:2013+AMD1:2018 CSV | PN-EN 60076-4:2004 | IEC 60076-4:2002 | PN-EN 60076-5:2009 | IEC 60076-5:2006 | PN-EN 60076-6:2008 | IEC 60076-6:2007 | PN-EN IEC 60076-11:2019-01 | IEC 60076-11:2018"},{"_id":"6a7f0bb91995264369d8e27f","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Transformatory i dławiki / Reactors and transformers","methodology":"Wytrzymałość zwarciowa / Short-circuit tests","parameters":[{"name":"Zakres / Range","range":"do 40 kA rms / 100 kA peak / up to and including 40 kA rms / 100 kA peak"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość zwarciowa / Short-circuit tests\nZakres / Range do 40 kA rms / 100 kA peak / up to and including 40 kA rms / 100 kA peak","reference":"PN-EN 60076-1:2011 | IEC 60076-1:2011 | PN-EN 60076-2:2011 | IEC 60076-2:2011 | PN-EN 60076-3:2014-02 | PN-EN 60076-3:2014-02/A1:2018-09 | IEC 60076-3:2013+AMD1:2018 CSV | PN-EN 60076-4:2004 | IEC 60076-4:2002 | PN-EN 60076-5:2009 | IEC 60076-5:2006 | PN-EN 60076-6:2008 | IEC 60076-6:2007 | PN-EN IEC 60076-11:2019-01 | IEC 60076-11:2018","norm_bases":["PN-EN 60076-1:2011","IEC 60076-1:2011","PN-EN 60076-2:2011","IEC 60076-2:2011","PN-EN 60076-3:2014-02","PN-EN 60076-3:2014-02/A1:2018-09","IEC 60076-3:2013+AMD1:2018 CSV","PN-EN 60076-4:2004","IEC 60076-4:2002","PN-EN 60076-5:2009","IEC 60076-5:2006","PN-EN 60076-6:2008","IEC 60076-6:2007","PN-EN IEC 60076-11:2019-01","IEC 60076-11:2018"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Transformatory i dławiki / Reactors and transformers Wytrzymałość zwarciowa / Short-circuit tests\nZakres / Range do 40 kA rms / 100 kA peak / up to and including 40 kA rms / 100 kA peak PN-EN 60076-1:2011 | IEC 60076-1:2011 | PN-EN 60076-2:2011 | IEC 60076-2:2011 | PN-EN 60076-3:2014-02 | PN-EN 60076-3:2014-02/A1:2018-09 | IEC 60076-3:2013+AMD1:2018 CSV | PN-EN 60076-4:2004 | IEC 60076-4:2002 | PN-EN 60076-5:2009 | IEC 60076-5:2006 | PN-EN 60076-6:2008 | IEC 60076-6:2007 | PN-EN IEC 60076-11:2019-01 | IEC 60076-11:2018 Transformatory i dlawiki / Reactors and transformers Wytrzymalosc zwarciowa / Short-circuit tests\nZakres / Range do 40 kA rms / 100 kA peak / up to and including 40 kA rms / 100 kA peak PN-EN 60076-1:2011 | IEC 60076-1:2011 | PN-EN 60076-2:2011 | IEC 60076-2:2011 | PN-EN 60076-3:2014-02 | PN-EN 60076-3:2014-02/A1:2018-09 | IEC 60076-3:2013+AMD1:2018 CSV | PN-EN 60076-4:2004 | IEC 60076-4:2002 | PN-EN 60076-5:2009 | IEC 60076-5:2006 | PN-EN 60076-6:2008 | IEC 60076-6:2007 | PN-EN IEC 60076-11:2019-01 | IEC 60076-11:2018","categories":["other"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 40 kA rms / 100 kA peak / up to and including 40 kA rms / 100 kA peak"}],"search_en":"Range Reference documents PN-EN 60076-1:2011 | IEC 60076-1:2011 | PN-EN 60076-2:2011 | IEC 60076-2:2011 | PN-EN 60076-3:2014-02 | PN-EN 60076-3:2014-02/A1:2018-09 | IEC 60076-3:2013+AMD1:2018 CSV | PN-EN 60076-4:2004 | IEC 60076-4:2002 | PN-EN 60076-5:2009 | IEC 60076-5:2006 | PN-EN 60076-6:2008 | IEC 60076-6:2007 | PN-EN IEC 60076-11:2019-01 | IEC 60076-11:2018","parameters_zh":[{"name":"范围 / Range","range":"do 40 kA rms / 100 kA peak / up to and including 40 kA rms / 100 kA peak"}],"search_zh":"范围 / Range PN-EN 60076-1:2011 | IEC 60076-1:2011 | PN-EN 60076-2:2011 | IEC 60076-2:2011 | PN-EN 60076-3:2014-02 | PN-EN 60076-3:2014-02/A1:2018-09 | IEC 60076-3:2013+AMD1:2018 CSV | PN-EN 60076-4:2004 | IEC 60076-4:2002 | PN-EN 60076-5:2009 | IEC 60076-5:2006 | PN-EN 60076-6:2008 | IEC 60076-6:2007 | PN-EN IEC 60076-11:2019-01 | IEC 60076-11:2018"},{"_id":"6a7f0bb91995264369d8e280","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Przekładniki prądowe / Current transformers, Przekładniki napięciowe / Voltage transformers, Przekładniki kombinowane / Combined transformers","methodology":"Wytrzymałość zwarciowa / Short-circuit tests","parameters":[{"name":"Zakres / Range","range":"do 100 kA rms / 250 kA peak / up to and including 100 kA rms / 250 kA peak"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość zwarciowa / Short-circuit tests\nZakres / Range do 100 kA rms / 250 kA peak / up to and including 100 kA rms / 250 kA peak","reference":"PN-EN 61869-1:2009 | IEC 61869-1:2007 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013","norm_bases":["PN-EN 61869-1:2009","IEC 61869-1:2007","PN-EN 61869-2:2013-06","IEC 61869-2:2012","PN-EN 61869-3:2011","IEC 61869-3:2011","PN-EN 61869-4:2014-09","IEC 61869-4:2013"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przekładniki prądowe / Current transformers, Przekładniki napięciowe / Voltage transformers, Przekładniki kombinowane / Combined transformers Wytrzymałość zwarciowa / Short-circuit tests\nZakres / Range do 100 kA rms / 250 kA peak / up to and including 100 kA rms / 250 kA peak PN-EN 61869-1:2009 | IEC 61869-1:2007 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 Przekladniki pradowe / Current transformers, Przekladniki napieciowe / Voltage transformers, Przekladniki kombinowane / Combined transformers Wytrzymalosc zwarciowa / Short-circuit tests\nZakres / Range do 100 kA rms / 250 kA peak / up to and including 100 kA rms / 250 kA peak PN-EN 61869-1:2009 | IEC 61869-1:2007 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013","categories":["other"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 100 kA rms / 250 kA peak / up to and including 100 kA rms / 250 kA peak"}],"search_en":"Range Reference documents PN-EN 61869-1:2009 | IEC 61869-1:2007 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013","parameters_zh":[{"name":"范围 / Range","range":"do 100 kA rms / 250 kA peak / up to and including 100 kA rms / 250 kA peak"}],"search_zh":"范围 / Range PN-EN 61869-1:2009 | IEC 61869-1:2007 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013"},{"_id":"6a7f0bb91995264369d8e281","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Przekładniki prądowe / Current transformers, Przekładniki napięciowe / Voltage transformers, Przekładniki kombinowane / Combined transformers","methodology":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:","parameters":[{"name":"udarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV"},{"name":"udarowym łączeniowym do Up=900 kV / switching impulse up to Up=900 kV"},{"name":"przemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nudarowym łączeniowym do Up=900 kV / switching impulse up to Up=900 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV","reference":"PN-EN 61869-1:2009 | IEC 61869-1:2007 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013","norm_bases":["PN-EN 61869-1:2009","IEC 61869-1:2007","PN-EN 61869-2:2013-06","IEC 61869-2:2012","PN-EN 61869-3:2011","IEC 61869-3:2011","PN-EN 61869-4:2014-09","IEC 61869-4:2013"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przekładniki prądowe / Current transformers, Przekładniki napięciowe / Voltage transformers, Przekładniki kombinowane / Combined transformers Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nudarowym łączeniowym do Up=900 kV / switching impulse up to Up=900 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV PN-EN 61869-1:2009 | IEC 61869-1:2007 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 Przekladniki pradowe / Current transformers, Przekladniki napieciowe / Voltage transformers, Przekladniki kombinowane / Combined transformers Wytrzymalosc elektryczna izolacji napieciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nudarowym laczeniowym do Up=900 kV / switching impulse up to Up=900 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV PN-EN 61869-1:2009 | IEC 61869-1:2007 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013","categories":["construction"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN 61869-1:2009 | IEC 61869-1:2007 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013"},{"_id":"6a7f0bb91995264369d8e282","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Przekładniki prądowe / Current transformers, Przekładniki napięciowe / Voltage transformers, Przekładniki kombinowane / Combined transformers","methodology":"Graniczne przyrosty temperatury / Temperature rise tests","parameters":[{"name":"Zakres / Range","range":"do 4 kA / up to and including 4 kA"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 4 kA / up to and including 4 kA","reference":"PN-EN 61869-1:2009 | IEC 61869-1:2007 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013","norm_bases":["PN-EN 61869-1:2009","IEC 61869-1:2007","PN-EN 61869-2:2013-06","IEC 61869-2:2012","PN-EN 61869-3:2011","IEC 61869-3:2011","PN-EN 61869-4:2014-09","IEC 61869-4:2013"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przekładniki prądowe / Current transformers, Przekładniki napięciowe / Voltage transformers, Przekładniki kombinowane / Combined transformers Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 4 kA / up to and including 4 kA PN-EN 61869-1:2009 | IEC 61869-1:2007 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 Przekladniki pradowe / Current transformers, Przekladniki napieciowe / Voltage transformers, Przekladniki kombinowane / Combined transformers Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 4 kA / up to and including 4 kA PN-EN 61869-1:2009 | IEC 61869-1:2007 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013","categories":["other"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 4 kA / up to and including 4 kA"}],"search_en":"Range Reference documents PN-EN 61869-1:2009 | IEC 61869-1:2007 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013","parameters_zh":[{"name":"范围 / Range","range":"do 4 kA / up to and including 4 kA"}],"search_zh":"范围 / Range PN-EN 61869-1:2009 | IEC 61869-1:2007 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013"},{"_id":"6a7f0bb91995264369d8e283","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Przekładniki prądowe / Current transformers, Przekładniki napięciowe / Voltage transformers, Przekładniki kombinowane / Combined transformers","methodology":"Wytrzymałość mechaniczna / Mechanical tests","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość mechaniczna / Mechanical tests","reference":"PN-EN 61869-1:2009 | IEC 61869-1:2007 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013","norm_bases":["PN-EN 61869-1:2009","IEC 61869-1:2007","PN-EN 61869-2:2013-06","IEC 61869-2:2012","PN-EN 61869-3:2011","IEC 61869-3:2011","PN-EN 61869-4:2014-09","IEC 61869-4:2013"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przekładniki prądowe / Current transformers, Przekładniki napięciowe / Voltage transformers, Przekładniki kombinowane / Combined transformers Wytrzymałość mechaniczna / Mechanical tests PN-EN 61869-1:2009 | IEC 61869-1:2007 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 Przekladniki pradowe / Current transformers, Przekladniki napieciowe / Voltage transformers, Przekladniki kombinowane / Combined transformers Wytrzymalosc mechaniczna / Mechanical tests PN-EN 61869-1:2009 | IEC 61869-1:2007 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013","categories":["other"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN 61869-1:2009 | IEC 61869-1:2007 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013"},{"_id":"6a7f0bb91995264369d8e284","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Przekładniki prądowe / Current transformers, Przekładniki napięciowe / Voltage transformers, Przekładniki kombinowane / Combined transformers","methodology":"Wewnętrzne zwarcie łukowe / Internal arc fault","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wewnętrzne zwarcie łukowe / Internal arc fault","reference":"PN-EN 61869-1:2009 | IEC 61869-1:2007 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013","norm_bases":["PN-EN 61869-1:2009","IEC 61869-1:2007","PN-EN 61869-2:2013-06","IEC 61869-2:2012","PN-EN 61869-3:2011","IEC 61869-3:2011","PN-EN 61869-4:2014-09","IEC 61869-4:2013"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przekładniki prądowe / Current transformers, Przekładniki napięciowe / Voltage transformers, Przekładniki kombinowane / Combined transformers Wewnętrzne zwarcie łukowe / Internal arc fault PN-EN 61869-1:2009 | IEC 61869-1:2007 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 Przekladniki pradowe / Current transformers, Przekladniki napieciowe / Voltage transformers, Przekladniki kombinowane / Combined transformers Wewnetrzne zwarcie lukowe / Internal arc fault PN-EN 61869-1:2009 | IEC 61869-1:2007 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013","categories":["other"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN 61869-1:2009 | IEC 61869-1:2007 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013"},{"_id":"6a7f0bb91995264369d8e285","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Szynoprzewody wysokonapięciowe / HV metal-enclosed bus","methodology":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:","parameters":[{"name":"udarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV"},{"name":"przemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV","reference":"ANSI/IEEE C 37.23:2015 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","norm_bases":["ANSI/IEEE C 37.23:2015","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Szynoprzewody wysokonapięciowe / HV metal-enclosed bus Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV ANSI/IEEE C 37.23:2015 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 Szynoprzewody wysokonapieciowe / HV metal-enclosed bus Wytrzymalosc elektryczna izolacji napieciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV ANSI/IEEE C 37.23:2015 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","categories":["materials","construction"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents ANSI/IEEE C 37.23:2015 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021"},{"_id":"6a7f0bb91995264369d8e286","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Szynoprzewody wysokonapięciowe / HV metal-enclosed bus","methodology":"Graniczne przyrosty temperatury / Temperature rise tests","parameters":[{"name":"Zakres / Range","range":"do 12 kA / up to and including 12 kA"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 12 kA / up to and including 12 kA","reference":"ANSI/IEEE C 37.23:2015 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","norm_bases":["ANSI/IEEE C 37.23:2015","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Szynoprzewody wysokonapięciowe / HV metal-enclosed bus Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 12 kA / up to and including 12 kA ANSI/IEEE C 37.23:2015 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 Szynoprzewody wysokonapieciowe / HV metal-enclosed bus Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 12 kA / up to and including 12 kA ANSI/IEEE C 37.23:2015 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","categories":["materials"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 12 kA / up to and including 12 kA"}],"search_en":"Range Reference documents ANSI/IEEE C 37.23:2015 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","parameters_zh":[{"name":"范围 / Range","range":"do 12 kA / up to and including 12 kA"}],"search_zh":"范围 / Range ANSI/IEEE C 37.23:2015 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021"},{"_id":"6a7f0bb91995264369d8e287","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Szynoprzewody wysokonapięciowe / HV metal-enclosed bus","methodology":"Rezystancja obwodu głównego / Main circuit resistance","parameters":[{"name":"Zakres / Range","range":"od 10-5 Ω / from 10-5 Ω"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Rezystancja obwodu głównego / Main circuit resistance\nZakres / Range od 10-5 Ω / from 10-5 Ω","reference":"ANSI/IEEE C 37.23:2015 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","norm_bases":["ANSI/IEEE C 37.23:2015","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Szynoprzewody wysokonapięciowe / HV metal-enclosed bus Rezystancja obwodu głównego / Main circuit resistance\nZakres / Range od 10-5 Ω / from 10-5 Ω ANSI/IEEE C 37.23:2015 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 Szynoprzewody wysokonapieciowe / HV metal-enclosed bus Rezystancja obwodu glownego / Main circuit resistance\nZakres / Range od 10-5 Ω / from 10-5 Ω ANSI/IEEE C 37.23:2015 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","categories":["materials"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"od 10-5 Ω / from 10-5 Ω"}],"search_en":"Range Reference documents ANSI/IEEE C 37.23:2015 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","parameters_zh":[{"name":"范围 / Range","range":"od 10-5 Ω / from 10-5 Ω"}],"search_zh":"范围 / Range ANSI/IEEE C 37.23:2015 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021"},{"_id":"6a7f0bb91995264369d8e288","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Szynoprzewody wysokonapięciowe / HV metal-enclosed bus","methodology":"Wytrzymałość zwarciowa / Short-circuit tests","parameters":[{"name":"Zakres / Range","range":"do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość zwarciowa / Short-circuit tests\nZakres / Range do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak","reference":"ANSI/IEEE C 37.23:2015 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","norm_bases":["ANSI/IEEE C 37.23:2015","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Szynoprzewody wysokonapięciowe / HV metal-enclosed bus Wytrzymałość zwarciowa / Short-circuit tests\nZakres / Range do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak ANSI/IEEE C 37.23:2015 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 Szynoprzewody wysokonapieciowe / HV metal-enclosed bus Wytrzymalosc zwarciowa / Short-circuit tests\nZakres / Range do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak ANSI/IEEE C 37.23:2015 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","categories":["materials"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak"}],"search_en":"Range Reference documents ANSI/IEEE C 37.23:2015 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021","parameters_zh":[{"name":"范围 / Range","range":"do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak"}],"search_zh":"范围 / Range ANSI/IEEE C 37.23:2015 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021"},{"_id":"6a7f0bb91995264369d8e289","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Przenośny sprzęt do uziemiania lub uziemiania i zwierania / Portable equipment for earthing or earthing and short-circuiting","methodology":"Wytrzymałość zwarciowa / Short-circuit tests","parameters":[{"name":"Zakres / Range","range":"do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość zwarciowa / Short-circuit tests\nZakres / Range do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak","reference":"PN-EN 61230:2011","norm_bases":["PN-EN 61230:2011"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przenośny sprzęt do uziemiania lub uziemiania i zwierania / Portable equipment for earthing or earthing and short-circuiting Wytrzymałość zwarciowa / Short-circuit tests\nZakres / Range do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak PN-EN 61230:2011 Przenosny sprzet do uziemiania lub uziemiania i zwierania / Portable equipment for earthing or earthing and short-circuiting Wytrzymalosc zwarciowa / Short-circuit tests\nZakres / Range do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak PN-EN 61230:2011","categories":["other"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak"}],"search_en":"Range Reference documents PN-EN 61230:2011","parameters_zh":[{"name":"范围 / Range","range":"do 120 kA rms / 300 kA peak / up to and including 120 kA rms / 300 kA peak"}],"search_zh":"范围 / Range PN-EN 61230:2011"},{"_id":"6a7f0bb91995264369d8e28a","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Drążki izolacyjne na napięcia od 1 kV do 750 kV / Insulation rods for voltages from 1 kV to 750 Kv","methodology":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:","parameters":[{"name":"przemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV","reference":"PN-EN 60832-1:2010 | PN-EN 60832-2:2010","norm_bases":["PN-EN 60832-1:2010","PN-EN 60832-2:2010"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Drążki izolacyjne na napięcia od 1 kV do 750 kV / Insulation rods for voltages from 1 kV to 750 Kv Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV PN-EN 60832-1:2010 | PN-EN 60832-2:2010 Drazki izolacyjne na napiecia od 1 kV do 750 kV / Insulation rods for voltages from 1 kV to 750 Kv Wytrzymalosc elektryczna izolacji napieciem / Impulse voltage withstand test:\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV PN-EN 60832-1:2010 | PN-EN 60832-2:2010","categories":["construction"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN 60832-1:2010 | PN-EN 60832-2:2010"},{"_id":"6a7f0bb91995264369d8e28b","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Kleszcze i chwytaki na napięcia powyżej 1 kV / Pliers and grippers for voltages above 1 kV","methodology":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:","parameters":[{"name":"przemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV","reference":"PB 102 Nr wyd. 6 z 2011-11-02","norm_bases":["PB 102 Nr wyd. 6 z 2011-11-02"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kleszcze i chwytaki na napięcia powyżej 1 kV / Pliers and grippers for voltages above 1 kV Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV PB 102 Nr wyd. 6 z 2011-11-02 Kleszcze i chwytaki na napiecia powyzej 1 kV / Pliers and grippers for voltages above 1 kV Wytrzymalosc elektryczna izolacji napieciem / Impulse voltage withstand test:\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV PB 102 Nr wyd. 6 z 2011-11-02","categories":["construction"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PB 102 Nr wyd. 6 z 2011-11-02"},{"_id":"6a7f0bb91995264369d8e28c","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Pomosty izolacyjne / Insulation platforms","methodology":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:","parameters":[{"name":"przemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV","reference":"PB 103 Nr wyd. 6 z 2011-11-02","norm_bases":["PB 103 Nr wyd. 6 z 2011-11-02"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomosty izolacyjne / Insulation platforms Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV PB 103 Nr wyd. 6 z 2011-11-02 Pomosty izolacyjne / Insulation platforms Wytrzymalosc elektryczna izolacji napieciem / Impulse voltage withstand test:\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV PB 103 Nr wyd. 6 z 2011-11-02","categories":["construction"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PB 103 Nr wyd. 6 z 2011-11-02"},{"_id":"6a7f0bb91995264369d8e28d","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Wskaźniki napięcia / Voltage indicators","methodology":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:","parameters":[{"name":"przemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV","reference":"PN-EN IEC 61243-1:2022-01 | PN-EN 61243-2:2002 | PN-EN 61243-2:2002/A2:2003 | PN-EN 61243-3:2015-04 | PN-EN 61243-5:2004","norm_bases":["PN-EN IEC 61243-1:2022-01","PN-EN 61243-2:2002","PN-EN 61243-2:2002/A2:2003","PN-EN 61243-3:2015-04","PN-EN 61243-5:2004"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wskaźniki napięcia / Voltage indicators Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV PN-EN IEC 61243-1:2022-01 | PN-EN 61243-2:2002 | PN-EN 61243-2:2002/A2:2003 | PN-EN 61243-3:2015-04 | PN-EN 61243-5:2004 Wskazniki napiecia / Voltage indicators Wytrzymalosc elektryczna izolacji napieciem / Impulse voltage withstand test:\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV PN-EN IEC 61243-1:2022-01 | PN-EN 61243-2:2002 | PN-EN 61243-2:2002/A2:2003 | PN-EN 61243-3:2015-04 | PN-EN 61243-5:2004","categories":["construction"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN IEC 61243-1:2022-01 | PN-EN 61243-2:2002 | PN-EN 61243-2:2002/A2:2003 | PN-EN 61243-3:2015-04 | PN-EN 61243-5:2004"},{"_id":"6a7f0bb91995264369d8e28e","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Uzgadniacze faz / Phase aligners","methodology":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:","parameters":[{"name":"przemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV","reference":"PN-EN 61481-1:2015-04 | PN-EN 61481-2:2015-04","norm_bases":["PN-EN 61481-1:2015-04","PN-EN 61481-2:2015-04"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Uzgadniacze faz / Phase aligners Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV PN-EN 61481-1:2015-04 | PN-EN 61481-2:2015-04 Uzgadniacze faz / Phase aligners Wytrzymalosc elektryczna izolacji napieciem / Impulse voltage withstand test:\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV PN-EN 61481-1:2015-04 | PN-EN 61481-2:2015-04","categories":["construction"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN 61481-1:2015-04 | PN-EN 61481-2:2015-04"},{"_id":"6a7f0bb91995264369d8e28f","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Rękawy z materiału izolacyjnego do prac pod napięciem / Insulating material sleeves for live work","methodology":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:","parameters":[{"name":"przemiennym 50 Hz do Ud=30 kV / power frequency 50 Hz up to Ud = 30 kV"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nprzemiennym 50 Hz do Ud=30 kV / power frequency 50 Hz up to Ud = 30 kV","reference":"PN-EN 60984:1998 | PN-EN 60984:1998/A1:2004","norm_bases":["PN-EN 60984:1998","PN-EN 60984:1998/A1:2004"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Rękawy z materiału izolacyjnego do prac pod napięciem / Insulating material sleeves for live work Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nprzemiennym 50 Hz do Ud=30 kV / power frequency 50 Hz up to Ud = 30 kV PN-EN 60984:1998 | PN-EN 60984:1998/A1:2004 Rekawy z materialu izolacyjnego do prac pod napieciem / Insulating material sleeves for live work Wytrzymalosc elektryczna izolacji napieciem / Impulse voltage withstand test:\nprzemiennym 50 Hz do Ud=30 kV / power frequency 50 Hz up to Ud = 30 kV PN-EN 60984:1998 | PN-EN 60984:1998/A1:2004","categories":["materials","construction"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN 60984:1998 | PN-EN 60984:1998/A1:2004"},{"_id":"6a7f0bb91995264369d8e290","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Chodniki gumowe elektroizolacyjne / Electro-insulating rubber sidewalks","methodology":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:","parameters":[{"name":"przemiennym 50 Hz do Ud=30 kV / power frequency 50 Hz up to Ud = 30 kV"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nprzemiennym 50 Hz do Ud=30 kV / power frequency 50 Hz up to Ud = 30 kV","reference":"PN-EN 61111:2009","norm_bases":["PN-EN 61111:2009"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Chodniki gumowe elektroizolacyjne / Electro-insulating rubber sidewalks Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nprzemiennym 50 Hz do Ud=30 kV / power frequency 50 Hz up to Ud = 30 kV PN-EN 61111:2009 Chodniki gumowe elektroizolacyjne / Electro-insulating rubber sidewalks Wytrzymalosc elektryczna izolacji napieciem / Impulse voltage withstand test:\nprzemiennym 50 Hz do Ud=30 kV / power frequency 50 Hz up to Ud = 30 kV PN-EN 61111:2009","categories":["materials","construction"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN 61111:2009"},{"_id":"6a7f0bb91995264369d8e291","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Rękawice elektroizolacyjne do pracy pod napięciem / Electrical insulating gloves for live work","methodology":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:","parameters":[{"name":"przemiennym 50 Hz do Ud=30 kV / power frequency 50 Hz up to Ud = 30 kV"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nprzemiennym 50 Hz do Ud=30 kV / power frequency 50 Hz up to Ud = 30 kV","reference":"PN-EN 60903:2006","norm_bases":["PN-EN 60903:2006"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Rękawice elektroizolacyjne do pracy pod napięciem / Electrical insulating gloves for live work Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nprzemiennym 50 Hz do Ud=30 kV / power frequency 50 Hz up to Ud = 30 kV PN-EN 60903:2006 Rekawice elektroizolacyjne do pracy pod napieciem / Electrical insulating gloves for live work Wytrzymalosc elektryczna izolacji napieciem / Impulse voltage withstand test:\nprzemiennym 50 Hz do Ud=30 kV / power frequency 50 Hz up to Ud = 30 kV PN-EN 60903:2006","categories":["construction"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN 60903:2006"},{"_id":"6a7f0bb91995264369d8e292","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Kalosze i półbuty elektroizolacyjne / Electrically insulated wellingtons and half-shoes","methodology":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:","parameters":[{"name":"przemiennym 50 Hz do Ud=30 kV / power frequency 50 Hz up to Ud = 30 kV"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nprzemiennym 50 Hz do Ud=30 kV / power frequency 50 Hz up to Ud = 30 kV","reference":"PN-EN 50321-1:2018-05","norm_bases":["PN-EN 50321-1:2018-05"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kalosze i półbuty elektroizolacyjne / Electrically insulated wellingtons and half-shoes Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nprzemiennym 50 Hz do Ud=30 kV / power frequency 50 Hz up to Ud = 30 kV PN-EN 50321-1:2018-05 Kalosze i polbuty elektroizolacyjne / Electrically insulated wellingtons and half-shoes Wytrzymalosc elektryczna izolacji napieciem / Impulse voltage withstand test:\nprzemiennym 50 Hz do Ud=30 kV / power frequency 50 Hz up to Ud = 30 kV PN-EN 50321-1:2018-05","categories":["construction"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN 50321-1:2018-05"},{"_id":"6a7f0bb91995264369d8e293","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Wyłączniki niskiego napięcia prądu przemiennego / Alternating-current Low voltage circuit-breakers","methodology":"Graniczne przyrosty temperatury / Temperature rise tests","parameters":[{"name":"Zakres / Range","range":"do 10 kA / up to and including 10 kA"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 10 kA / up to and including 10 kA","reference":"PN-EN 60947-2 :2018-01 | PN-EN 60947-2 :2018-01/A1:2020-06 | PN-EN IEC 60947-1 :2021-07 | IEC 60947-1:2020","norm_bases":["PN-EN 60947-2 :2018-01","PN-EN 60947-2 :2018-01/A1:2020-06","PN-EN IEC 60947-1 :2021-07","IEC 60947-1:2020"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyłączniki niskiego napięcia prądu przemiennego / Alternating-current Low voltage circuit-breakers Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 10 kA / up to and including 10 kA PN-EN 60947-2 :2018-01 | PN-EN 60947-2 :2018-01/A1:2020-06 | PN-EN IEC 60947-1 :2021-07 | IEC 60947-1:2020 Wylaczniki niskiego napiecia pradu przemiennego / Alternating-current Low voltage circuit-breakers Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 10 kA / up to and including 10 kA PN-EN 60947-2 :2018-01 | PN-EN 60947-2 :2018-01/A1:2020-06 | PN-EN IEC 60947-1 :2021-07 | IEC 60947-1:2020","categories":["other"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 10 kA / up to and including 10 kA"}],"search_en":"Range Reference documents PN-EN 60947-2 :2018-01 | PN-EN 60947-2 :2018-01/A1:2020-06 | PN-EN IEC 60947-1 :2021-07 | IEC 60947-1:2020","parameters_zh":[{"name":"范围 / Range","range":"do 10 kA / up to and including 10 kA"}],"search_zh":"范围 / Range PN-EN 60947-2 :2018-01 | PN-EN 60947-2 :2018-01/A1:2020-06 | PN-EN IEC 60947-1 :2021-07 | IEC 60947-1:2020"},{"_id":"6a7f0bb91995264369d8e294","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Wyłączniki niskiego napięcia prądu przemiennego / Alternating-current Low voltage circuit-breakers","methodology":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:","parameters":[{"name":"udarowym piorunowym do Up=25 kV / lightning impulse up to Up = 25 kV"},{"name":"przemiennym 50 Hz do Ud=5 kV / power frequency 50 Hz up to Ud = 5 kV"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=25 kV / lightning impulse up to Up = 25 kV\nprzemiennym 50 Hz do Ud=5 kV / power frequency 50 Hz up to Ud = 5 kV","reference":"PN-EN 60947-2 :2018-01 | PN-EN 60947-2 :2018-01/A1:2020-06 | PN-EN IEC 60947-1 :2021-07 | IEC 60947-1:2020","norm_bases":["PN-EN 60947-2 :2018-01","PN-EN 60947-2 :2018-01/A1:2020-06","PN-EN IEC 60947-1 :2021-07","IEC 60947-1:2020"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyłączniki niskiego napięcia prądu przemiennego / Alternating-current Low voltage circuit-breakers Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=25 kV / lightning impulse up to Up = 25 kV\nprzemiennym 50 Hz do Ud=5 kV / power frequency 50 Hz up to Ud = 5 kV PN-EN 60947-2 :2018-01 | PN-EN 60947-2 :2018-01/A1:2020-06 | PN-EN IEC 60947-1 :2021-07 | IEC 60947-1:2020 Wylaczniki niskiego napiecia pradu przemiennego / Alternating-current Low voltage circuit-breakers Wytrzymalosc elektryczna izolacji napieciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=25 kV / lightning impulse up to Up = 25 kV\nprzemiennym 50 Hz do Ud=5 kV / power frequency 50 Hz up to Ud = 5 kV PN-EN 60947-2 :2018-01 | PN-EN 60947-2 :2018-01/A1:2020-06 | PN-EN IEC 60947-1 :2021-07 | IEC 60947-1:2020","categories":["construction"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN 60947-2 :2018-01 | PN-EN 60947-2 :2018-01/A1:2020-06 | PN-EN IEC 60947-1 :2021-07 | IEC 60947-1:2020"},{"_id":"6a7f0bb91995264369d8e295","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Wyłączniki niskiego napięcia prądu przemiennego / Alternating-current Low voltage circuit-breakers","methodology":"Wytrzymałość zwarciowa / Short-circuit tests","parameters":[{"name":"Zakres / Range","range":"do 100 kA rms / 230 kA peak / up to and including 100 kA rms / 230 kA peak"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość zwarciowa / Short-circuit tests\nZakres / Range do 100 kA rms / 230 kA peak / up to and including 100 kA rms / 230 kA peak","reference":"PN-EN 60947-2 :2018-01 | PN-EN 60947-2 :2018-01/A1:2020-06 | PN-EN IEC 60947-1 :2021-07 | IEC 60947-1:2020","norm_bases":["PN-EN 60947-2 :2018-01","PN-EN 60947-2 :2018-01/A1:2020-06","PN-EN IEC 60947-1 :2021-07","IEC 60947-1:2020"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyłączniki niskiego napięcia prądu przemiennego / Alternating-current Low voltage circuit-breakers Wytrzymałość zwarciowa / Short-circuit tests\nZakres / Range do 100 kA rms / 230 kA peak / up to and including 100 kA rms / 230 kA peak PN-EN 60947-2 :2018-01 | PN-EN 60947-2 :2018-01/A1:2020-06 | PN-EN IEC 60947-1 :2021-07 | IEC 60947-1:2020 Wylaczniki niskiego napiecia pradu przemiennego / Alternating-current Low voltage circuit-breakers Wytrzymalosc zwarciowa / Short-circuit tests\nZakres / Range do 100 kA rms / 230 kA peak / up to and including 100 kA rms / 230 kA peak PN-EN 60947-2 :2018-01 | PN-EN 60947-2 :2018-01/A1:2020-06 | PN-EN IEC 60947-1 :2021-07 | IEC 60947-1:2020","categories":["other"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 100 kA rms / 230 kA peak / up to and including 100 kA rms / 230 kA peak"}],"search_en":"Range Reference documents PN-EN 60947-2 :2018-01 | PN-EN 60947-2 :2018-01/A1:2020-06 | PN-EN IEC 60947-1 :2021-07 | IEC 60947-1:2020","parameters_zh":[{"name":"范围 / Range","range":"do 100 kA rms / 230 kA peak / up to and including 100 kA rms / 230 kA peak"}],"search_zh":"范围 / Range PN-EN 60947-2 :2018-01 | PN-EN 60947-2 :2018-01/A1:2020-06 | PN-EN IEC 60947-1 :2021-07 | IEC 60947-1:2020"},{"_id":"6a7f0bb91995264369d8e296","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Styczniki i rozruszniki niskonapięciowe / Contactors and motor-starters","methodology":"Graniczne przyrosty temperatury / Temperature rise tests","parameters":[{"name":"Zakres / Range","range":"do 10 kA / up to and including 10 kA"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 10 kA / up to and including 10 kA","reference":"PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | PN-EN IEC 60947-4-1:2019-05 | PN-EN IEC 60947-4-3:2014-09","norm_bases":["PN-EN IEC 60947-1:2021-07","IEC 60947-1:2020","PN-EN IEC 60947-4-1:2019-05","PN-EN IEC 60947-4-3:2014-09"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Styczniki i rozruszniki niskonapięciowe / Contactors and motor-starters Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 10 kA / up to and including 10 kA PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | PN-EN IEC 60947-4-1:2019-05 | PN-EN IEC 60947-4-3:2014-09 Styczniki i rozruszniki niskonapieciowe / Contactors and motor-starters Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 10 kA / up to and including 10 kA PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | PN-EN IEC 60947-4-1:2019-05 | PN-EN IEC 60947-4-3:2014-09","categories":["other"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 10 kA / up to and including 10 kA"}],"search_en":"Range Reference documents PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | PN-EN IEC 60947-4-1:2019-05 | PN-EN IEC 60947-4-3:2014-09","parameters_zh":[{"name":"范围 / Range","range":"do 10 kA / up to and including 10 kA"}],"search_zh":"范围 / Range PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | PN-EN IEC 60947-4-1:2019-05 | PN-EN IEC 60947-4-3:2014-09"},{"_id":"6a7f0bb91995264369d8e297","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Styczniki i rozruszniki niskonapięciowe / Contactors and motor-starters","methodology":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:","parameters":[{"name":"udarowym piorunowym do Up=25 kV / lightning impulse up to Up = 25 kV"},{"name":"przemiennym 50 Hz do Ud=5 kV / power frequency 50 Hz up to Ud = 5 kV"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=25 kV / lightning impulse up to Up = 25 kV\nprzemiennym 50 Hz do Ud=5 kV / power frequency 50 Hz up to Ud = 5 kV","reference":"PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | PN-EN IEC 60947-4-1:2019-05 | PN-EN IEC 60947-4-3:2014-09","norm_bases":["PN-EN IEC 60947-1:2021-07","IEC 60947-1:2020","PN-EN IEC 60947-4-1:2019-05","PN-EN IEC 60947-4-3:2014-09"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Styczniki i rozruszniki niskonapięciowe / Contactors and motor-starters Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=25 kV / lightning impulse up to Up = 25 kV\nprzemiennym 50 Hz do Ud=5 kV / power frequency 50 Hz up to Ud = 5 kV PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | PN-EN IEC 60947-4-1:2019-05 | PN-EN IEC 60947-4-3:2014-09 Styczniki i rozruszniki niskonapieciowe / Contactors and motor-starters Wytrzymalosc elektryczna izolacji napieciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=25 kV / lightning impulse up to Up = 25 kV\nprzemiennym 50 Hz do Ud=5 kV / power frequency 50 Hz up to Ud = 5 kV PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | PN-EN IEC 60947-4-1:2019-05 | PN-EN IEC 60947-4-3:2014-09","categories":["construction"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | PN-EN IEC 60947-4-1:2019-05 | PN-EN IEC 60947-4-3:2014-09"},{"_id":"6a7f0bb91995264369d8e298","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Styczniki i rozruszniki niskonapięciowe / Contactors and motor-starters","methodology":"Zdolność łączenia / Making and breaking capacity","parameters":[{"name":"Zakres / Range","range":"do 63 kA / up to and including 63 kA"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Zdolność łączenia / Making and breaking capacity\nZakres / Range do 63 kA / up to and including 63 kA","reference":"PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | PN-EN IEC 60947-4-1:2019-05 | PN-EN IEC 60947-4-3:2014-09","norm_bases":["PN-EN IEC 60947-1:2021-07","IEC 60947-1:2020","PN-EN IEC 60947-4-1:2019-05","PN-EN IEC 60947-4-3:2014-09"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Styczniki i rozruszniki niskonapięciowe / Contactors and motor-starters Zdolność łączenia / Making and breaking capacity\nZakres / Range do 63 kA / up to and including 63 kA PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | PN-EN IEC 60947-4-1:2019-05 | PN-EN IEC 60947-4-3:2014-09 Styczniki i rozruszniki niskonapieciowe / Contactors and motor-starters Zdolnosc laczenia / Making and breaking capacity\nZakres / Range do 63 kA / up to and including 63 kA PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | PN-EN IEC 60947-4-1:2019-05 | PN-EN IEC 60947-4-3:2014-09","categories":["other"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 63 kA / up to and including 63 kA"}],"search_en":"Range Reference documents PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | PN-EN IEC 60947-4-1:2019-05 | PN-EN IEC 60947-4-3:2014-09","parameters_zh":[{"name":"范围 / Range","range":"do 63 kA / up to and including 63 kA"}],"search_zh":"范围 / Range PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | PN-EN IEC 60947-4-1:2019-05 | PN-EN IEC 60947-4-3:2014-09"},{"_id":"6a7f0bb91995264369d8e299","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Styczniki i rozruszniki niskonapięciowe / Contactors and motor-starters","methodology":"Wytrzymałość zwarciowa / Short-circuit tests","parameters":[{"name":"Zakres / Range","range":"AC: do 100 kA rms / 230 kA peak / AC: up to and including 100 kA rms / 230 kA peak"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość zwarciowa / Short-circuit tests\nZakres / Range AC: do 100 kA rms / 230 kA peak / AC: up to and including 100 kA rms / 230 kA peak","reference":"PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | PN-EN IEC 60947-4-1:2019-05 | PN-EN IEC 60947-4-3:2014-09","norm_bases":["PN-EN IEC 60947-1:2021-07","IEC 60947-1:2020","PN-EN IEC 60947-4-1:2019-05","PN-EN IEC 60947-4-3:2014-09"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Styczniki i rozruszniki niskonapięciowe / Contactors and motor-starters Wytrzymałość zwarciowa / Short-circuit tests\nZakres / Range AC: do 100 kA rms / 230 kA peak / AC: up to and including 100 kA rms / 230 kA peak PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | PN-EN IEC 60947-4-1:2019-05 | PN-EN IEC 60947-4-3:2014-09 Styczniki i rozruszniki niskonapieciowe / Contactors and motor-starters Wytrzymalosc zwarciowa / Short-circuit tests\nZakres / Range AC: do 100 kA rms / 230 kA peak / AC: up to and including 100 kA rms / 230 kA peak PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | PN-EN IEC 60947-4-1:2019-05 | PN-EN IEC 60947-4-3:2014-09","categories":["other"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"AC: do 100 kA rms / 230 kA peak / AC: up to and including 100 kA rms / 230 kA peak"}],"search_en":"Range Reference documents PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | PN-EN IEC 60947-4-1:2019-05 | PN-EN IEC 60947-4-3:2014-09","parameters_zh":[{"name":"范围 / Range","range":"AC: do 100 kA rms / 230 kA peak / AC: up to and including 100 kA rms / 230 kA peak"}],"search_zh":"范围 / Range PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | PN-EN IEC 60947-4-1:2019-05 | PN-EN IEC 60947-4-3:2014-09"},{"_id":"6a7f0bb91995264369d8e29a","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Styczniki i rozruszniki niskonapięciowe / Contactors and motor-starters","methodology":"Trwałość mechaniczna / Mechanical endurance","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Trwałość mechaniczna / Mechanical endurance","reference":"PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | PN-EN IEC 60947-4-1:2019-05 | PN-EN IEC 60947-4-3:2014-09","norm_bases":["PN-EN IEC 60947-1:2021-07","IEC 60947-1:2020","PN-EN IEC 60947-4-1:2019-05","PN-EN IEC 60947-4-3:2014-09"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Styczniki i rozruszniki niskonapięciowe / Contactors and motor-starters Trwałość mechaniczna / Mechanical endurance PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | PN-EN IEC 60947-4-1:2019-05 | PN-EN IEC 60947-4-3:2014-09 Styczniki i rozruszniki niskonapieciowe / Contactors and motor-starters Trwalosc mechaniczna / Mechanical endurance PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | PN-EN IEC 60947-4-1:2019-05 | PN-EN IEC 60947-4-3:2014-09","categories":["other"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | PN-EN IEC 60947-4-1:2019-05 | PN-EN IEC 60947-4-3:2014-09"},{"_id":"6a7f0bb91995264369d8e29b","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Niskonapięciowe rozłączniki, odłączniki, rozłączniki izolacyjne i zestawy łączników z bezpiecznikami / Low voltage Switches, disconnectors, switch-disconnectors and fuse-combination units, Niskonapięciowe aparaty i łączniki sterownicze / Low voltage control circuit devices and switching elements - Electromechanical control circuit devices, Niskonapięciowe łączniki wielozadaniowe – automatyczne urządzenia przełączające / Low voltage multiple function equipment - Transfer switching equipment","methodology":"Graniczne przyrosty temperatury / Temperature rise tests","parameters":[{"name":"Zakres / Range","range":"do 10 kA / up to and including 10 kA"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 10 kA / up to and including 10 kA","reference":"PN-EN IEC 60947-3:2021-07 | IEC 60947-3:2020 | PN EN 60947-5-1:2018-02 | PN-EN 60947-6-1:2009 | PN-EN IEC 60947-6-1:2023-10 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020","norm_bases":["PN-EN IEC 60947-3:2021-07","IEC 60947-3:2020","PN EN 60947-5-1:2018-02","PN-EN 60947-6-1:2009","PN-EN IEC 60947-6-1:2023-10","PN-EN IEC 60947-1:2021-07","IEC 60947-1:2020"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Niskonapięciowe rozłączniki, odłączniki, rozłączniki izolacyjne i zestawy łączników z bezpiecznikami / Low voltage Switches, disconnectors, switch-disconnectors and fuse-combination units, Niskonapięciowe aparaty i łączniki sterownicze / Low voltage control circuit devices and switching elements - Electromechanical control circuit devices, Niskonapięciowe łączniki wielozadaniowe – automatyczne urządzenia przełączające / Low voltage multiple function equipment - Transfer switching equipment Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 10 kA / up to and including 10 kA PN-EN IEC 60947-3:2021-07 | IEC 60947-3:2020 | PN EN 60947-5-1:2018-02 | PN-EN 60947-6-1:2009 | PN-EN IEC 60947-6-1:2023-10 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 Niskonapieciowe rozlaczniki, odlaczniki, rozlaczniki izolacyjne i zestawy lacznikow z bezpiecznikami / Low voltage Switches, disconnectors, switch-disconnectors and fuse-combination units, Niskonapieciowe aparaty i laczniki sterownicze / Low voltage control circuit devices and switching elements - Electromechanical control circuit devices, Niskonapieciowe laczniki wielozadaniowe – automatyczne urzadzenia przelaczajace / Low voltage multiple function equipment - Transfer switching equipment Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 10 kA / up to and including 10 kA PN-EN IEC 60947-3:2021-07 | IEC 60947-3:2020 | PN EN 60947-5-1:2018-02 | PN-EN 60947-6-1:2009 | PN-EN IEC 60947-6-1:2023-10 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020","categories":["construction"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 10 kA / up to and including 10 kA"}],"search_en":"Range Reference documents PN-EN IEC 60947-3:2021-07 | IEC 60947-3:2020 | PN EN 60947-5-1:2018-02 | PN-EN 60947-6-1:2009 | PN-EN IEC 60947-6-1:2023-10 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020","parameters_zh":[{"name":"范围 / Range","range":"do 10 kA / up to and including 10 kA"}],"search_zh":"范围 / Range PN-EN IEC 60947-3:2021-07 | IEC 60947-3:2020 | PN EN 60947-5-1:2018-02 | PN-EN 60947-6-1:2009 | PN-EN IEC 60947-6-1:2023-10 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020"},{"_id":"6a7f0bb91995264369d8e29c","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Niskonapięciowe rozłączniki, odłączniki, rozłączniki izolacyjne i zestawy łączników z bezpiecznikami / Low voltage Switches, disconnectors, switch-disconnectors and fuse-combination units, Niskonapięciowe aparaty i łączniki sterownicze / Low voltage control circuit devices and switching elements - Electromechanical control circuit devices, Niskonapięciowe łączniki wielozadaniowe – automatyczne urządzenia przełączające / Low voltage multiple function equipment - Transfer switching equipment","methodology":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:","parameters":[{"name":"udarowym piorunowym do Up=25 kV / lightning impulse up to Up = 25 kV"},{"name":"przemiennym 50 Hz do Ud=5 kV / power frequency 50 Hz up to Ud = 5 kV"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=25 kV / lightning impulse up to Up = 25 kV\nprzemiennym 50 Hz do Ud=5 kV / power frequency 50 Hz up to Ud = 5 kV","reference":"PN-EN IEC 60947-3:2021-07 | IEC 60947-3:2020 | PN EN 60947-5-1:2018-02 | PN-EN 60947-6-1:2009 | PN-EN IEC 60947-6-1:2023-10 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020","norm_bases":["PN-EN IEC 60947-3:2021-07","IEC 60947-3:2020","PN EN 60947-5-1:2018-02","PN-EN 60947-6-1:2009","PN-EN IEC 60947-6-1:2023-10","PN-EN IEC 60947-1:2021-07","IEC 60947-1:2020"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Niskonapięciowe rozłączniki, odłączniki, rozłączniki izolacyjne i zestawy łączników z bezpiecznikami / Low voltage Switches, disconnectors, switch-disconnectors and fuse-combination units, Niskonapięciowe aparaty i łączniki sterownicze / Low voltage control circuit devices and switching elements - Electromechanical control circuit devices, Niskonapięciowe łączniki wielozadaniowe – automatyczne urządzenia przełączające / Low voltage multiple function equipment - Transfer switching equipment Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=25 kV / lightning impulse up to Up = 25 kV\nprzemiennym 50 Hz do Ud=5 kV / power frequency 50 Hz up to Ud = 5 kV PN-EN IEC 60947-3:2021-07 | IEC 60947-3:2020 | PN EN 60947-5-1:2018-02 | PN-EN 60947-6-1:2009 | PN-EN IEC 60947-6-1:2023-10 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 Niskonapieciowe rozlaczniki, odlaczniki, rozlaczniki izolacyjne i zestawy lacznikow z bezpiecznikami / Low voltage Switches, disconnectors, switch-disconnectors and fuse-combination units, Niskonapieciowe aparaty i laczniki sterownicze / Low voltage control circuit devices and switching elements - Electromechanical control circuit devices, Niskonapieciowe laczniki wielozadaniowe – automatyczne urzadzenia przelaczajace / Low voltage multiple function equipment - Transfer switching equipment Wytrzymalosc elektryczna izolacji napieciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=25 kV / lightning impulse up to Up = 25 kV\nprzemiennym 50 Hz do Ud=5 kV / power frequency 50 Hz up to Ud = 5 kV PN-EN IEC 60947-3:2021-07 | IEC 60947-3:2020 | PN EN 60947-5-1:2018-02 | PN-EN 60947-6-1:2009 | PN-EN IEC 60947-6-1:2023-10 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020","categories":["construction"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN IEC 60947-3:2021-07 | IEC 60947-3:2020 | PN EN 60947-5-1:2018-02 | PN-EN 60947-6-1:2009 | PN-EN IEC 60947-6-1:2023-10 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020"},{"_id":"6a7f0bb91995264369d8e29d","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Niskonapięciowe rozłączniki, odłączniki, rozłączniki izolacyjne i zestawy łączników z bezpiecznikami / Low voltage Switches, disconnectors, switch-disconnectors and fuse-combination units, Niskonapięciowe aparaty i łączniki sterownicze / Low voltage control circuit devices and switching elements - Electromechanical control circuit devices, Niskonapięciowe łączniki wielozadaniowe – automatyczne urządzenia przełączające / Low voltage multiple function equipment - Transfer switching equipment","methodology":"Wytrzymałość zwarciowa / Short-circuit tests","parameters":[{"name":"Zakres / Range","range":"do 100 kA rms / 230 kA peak / up to and including 100 kA rms / 230 kA peak"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość zwarciowa / Short-circuit tests\nZakres / Range do 100 kA rms / 230 kA peak / up to and including 100 kA rms / 230 kA peak","reference":"PN-EN IEC 60947-3:2021-07 | IEC 60947-3:2020 | PN EN 60947-5-1:2018-02 | PN-EN 60947-6-1:2009 | PN-EN IEC 60947-6-1:2023-10 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020","norm_bases":["PN-EN IEC 60947-3:2021-07","IEC 60947-3:2020","PN EN 60947-5-1:2018-02","PN-EN 60947-6-1:2009","PN-EN IEC 60947-6-1:2023-10","PN-EN IEC 60947-1:2021-07","IEC 60947-1:2020"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Niskonapięciowe rozłączniki, odłączniki, rozłączniki izolacyjne i zestawy łączników z bezpiecznikami / Low voltage Switches, disconnectors, switch-disconnectors and fuse-combination units, Niskonapięciowe aparaty i łączniki sterownicze / Low voltage control circuit devices and switching elements - Electromechanical control circuit devices, Niskonapięciowe łączniki wielozadaniowe – automatyczne urządzenia przełączające / Low voltage multiple function equipment - Transfer switching equipment Wytrzymałość zwarciowa / Short-circuit tests\nZakres / Range do 100 kA rms / 230 kA peak / up to and including 100 kA rms / 230 kA peak PN-EN IEC 60947-3:2021-07 | IEC 60947-3:2020 | PN EN 60947-5-1:2018-02 | PN-EN 60947-6-1:2009 | PN-EN IEC 60947-6-1:2023-10 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 Niskonapieciowe rozlaczniki, odlaczniki, rozlaczniki izolacyjne i zestawy lacznikow z bezpiecznikami / Low voltage Switches, disconnectors, switch-disconnectors and fuse-combination units, Niskonapieciowe aparaty i laczniki sterownicze / Low voltage control circuit devices and switching elements - Electromechanical control circuit devices, Niskonapieciowe laczniki wielozadaniowe – automatyczne urzadzenia przelaczajace / Low voltage multiple function equipment - Transfer switching equipment Wytrzymalosc zwarciowa / Short-circuit tests\nZakres / Range do 100 kA rms / 230 kA peak / up to and including 100 kA rms / 230 kA peak PN-EN IEC 60947-3:2021-07 | IEC 60947-3:2020 | PN EN 60947-5-1:2018-02 | PN-EN 60947-6-1:2009 | PN-EN IEC 60947-6-1:2023-10 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020","categories":["construction"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 100 kA rms / 230 kA peak / up to and including 100 kA rms / 230 kA peak"}],"search_en":"Range Reference documents PN-EN IEC 60947-3:2021-07 | IEC 60947-3:2020 | PN EN 60947-5-1:2018-02 | PN-EN 60947-6-1:2009 | PN-EN IEC 60947-6-1:2023-10 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020","parameters_zh":[{"name":"范围 / Range","range":"do 100 kA rms / 230 kA peak / up to and including 100 kA rms / 230 kA peak"}],"search_zh":"范围 / Range PN-EN IEC 60947-3:2021-07 | IEC 60947-3:2020 | PN EN 60947-5-1:2018-02 | PN-EN 60947-6-1:2009 | PN-EN IEC 60947-6-1:2023-10 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020"},{"_id":"6a7f0bb91995264369d8e29e","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Niskonapięciowe rozłączniki, odłączniki, rozłączniki izolacyjne i zestawy łączników z bezpiecznikami / Low voltage Switches, disconnectors, switch-disconnectors and fuse-combination units, Niskonapięciowe aparaty i łączniki sterownicze / Low voltage control circuit devices and switching elements - Electromechanical control circuit devices, Niskonapięciowe łączniki wielozadaniowe – automatyczne urządzenia przełączające / Low voltage multiple function equipment - Transfer switching equipment","methodology":"Trwałość mechaniczna / Mechanical endurance","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Trwałość mechaniczna / Mechanical endurance","reference":"PN-EN IEC 60947-3:2021-07 | IEC 60947-3:2020 | PN EN 60947-5-1:2018-02 | PN-EN 60947-6-1:2009 | PN-EN IEC 60947-6-1:2023-10 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020","norm_bases":["PN-EN IEC 60947-3:2021-07","IEC 60947-3:2020","PN EN 60947-5-1:2018-02","PN-EN 60947-6-1:2009","PN-EN IEC 60947-6-1:2023-10","PN-EN IEC 60947-1:2021-07","IEC 60947-1:2020"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Niskonapięciowe rozłączniki, odłączniki, rozłączniki izolacyjne i zestawy łączników z bezpiecznikami / Low voltage Switches, disconnectors, switch-disconnectors and fuse-combination units, Niskonapięciowe aparaty i łączniki sterownicze / Low voltage control circuit devices and switching elements - Electromechanical control circuit devices, Niskonapięciowe łączniki wielozadaniowe – automatyczne urządzenia przełączające / Low voltage multiple function equipment - Transfer switching equipment Trwałość mechaniczna / Mechanical endurance PN-EN IEC 60947-3:2021-07 | IEC 60947-3:2020 | PN EN 60947-5-1:2018-02 | PN-EN 60947-6-1:2009 | PN-EN IEC 60947-6-1:2023-10 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 Niskonapieciowe rozlaczniki, odlaczniki, rozlaczniki izolacyjne i zestawy lacznikow z bezpiecznikami / Low voltage Switches, disconnectors, switch-disconnectors and fuse-combination units, Niskonapieciowe aparaty i laczniki sterownicze / Low voltage control circuit devices and switching elements - Electromechanical control circuit devices, Niskonapieciowe laczniki wielozadaniowe – automatyczne urzadzenia przelaczajace / Low voltage multiple function equipment - Transfer switching equipment Trwalosc mechaniczna / Mechanical endurance PN-EN IEC 60947-3:2021-07 | IEC 60947-3:2020 | PN EN 60947-5-1:2018-02 | PN-EN 60947-6-1:2009 | PN-EN IEC 60947-6-1:2023-10 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020","categories":["construction"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN IEC 60947-3:2021-07 | IEC 60947-3:2020 | PN EN 60947-5-1:2018-02 | PN-EN 60947-6-1:2009 | PN-EN IEC 60947-6-1:2023-10 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020"},{"_id":"6a7f0bb91995264369d8e29f","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Niskonapięciowe rozłączniki, odłączniki, rozłączniki izolacyjne i zestawy łączników z bezpiecznikami / Low voltage Switches, disconnectors, switch-disconnectors and fuse-combination units, Niskonapięciowe aparaty i łączniki sterownicze / Low voltage control circuit devices and switching elements - Electromechanical control circuit devices, Niskonapięciowe łączniki wielozadaniowe – automatyczne urządzenia przełączające / Low voltage multiple function equipment - Transfer switching equipment","methodology":"Trwałość łączeniowa / Switching durability","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Trwałość łączeniowa / Switching durability","reference":"PN-EN IEC 60947-3:2021-07 | IEC 60947-3:2020 | PN EN 60947-5-1:2018-02 | PN-EN 60947-6-1:2009 | PN-EN IEC 60947-6-1:2023-10 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020","norm_bases":["PN-EN IEC 60947-3:2021-07","IEC 60947-3:2020","PN EN 60947-5-1:2018-02","PN-EN 60947-6-1:2009","PN-EN IEC 60947-6-1:2023-10","PN-EN IEC 60947-1:2021-07","IEC 60947-1:2020"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Niskonapięciowe rozłączniki, odłączniki, rozłączniki izolacyjne i zestawy łączników z bezpiecznikami / Low voltage Switches, disconnectors, switch-disconnectors and fuse-combination units, Niskonapięciowe aparaty i łączniki sterownicze / Low voltage control circuit devices and switching elements - Electromechanical control circuit devices, Niskonapięciowe łączniki wielozadaniowe – automatyczne urządzenia przełączające / Low voltage multiple function equipment - Transfer switching equipment Trwałość łączeniowa / Switching durability PN-EN IEC 60947-3:2021-07 | IEC 60947-3:2020 | PN EN 60947-5-1:2018-02 | PN-EN 60947-6-1:2009 | PN-EN IEC 60947-6-1:2023-10 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 Niskonapieciowe rozlaczniki, odlaczniki, rozlaczniki izolacyjne i zestawy lacznikow z bezpiecznikami / Low voltage Switches, disconnectors, switch-disconnectors and fuse-combination units, Niskonapieciowe aparaty i laczniki sterownicze / Low voltage control circuit devices and switching elements - Electromechanical control circuit devices, Niskonapieciowe laczniki wielozadaniowe – automatyczne urzadzenia przelaczajace / Low voltage multiple function equipment - Transfer switching equipment Trwalosc laczeniowa / Switching durability PN-EN IEC 60947-3:2021-07 | IEC 60947-3:2020 | PN EN 60947-5-1:2018-02 | PN-EN 60947-6-1:2009 | PN-EN IEC 60947-6-1:2023-10 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020","categories":["construction"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN IEC 60947-3:2021-07 | IEC 60947-3:2020 | PN EN 60947-5-1:2018-02 | PN-EN 60947-6-1:2009 | PN-EN IEC 60947-6-1:2023-10 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020"},{"_id":"6a7f0bb91995264369d8e2a0","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Listwy zaciskowe do przewodów miedzianych / Terminal blocks for copper conductors","methodology":"Wytrzymałość mechaniczna / Mechanical strength","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość mechaniczna / Mechanical strength","reference":"PN-EN 60947-7-1:2012 | IEC 60947-7-1:2009 | PN-EN 60947-7-2:2012 | IEC 60947-7-2:2009 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020","norm_bases":["PN-EN 60947-7-1:2012","IEC 60947-7-1:2009","PN-EN 60947-7-2:2012","IEC 60947-7-2:2009","PN-EN IEC 60947-1:2021-07","IEC 60947-1:2020"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Listwy zaciskowe do przewodów miedzianych / Terminal blocks for copper conductors Wytrzymałość mechaniczna / Mechanical strength PN-EN 60947-7-1:2012 | IEC 60947-7-1:2009 | PN-EN 60947-7-2:2012 | IEC 60947-7-2:2009 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 Listwy zaciskowe do przewodow miedzianych / Terminal blocks for copper conductors Wytrzymalosc mechaniczna / Mechanical strength PN-EN 60947-7-1:2012 | IEC 60947-7-1:2009 | PN-EN 60947-7-2:2012 | IEC 60947-7-2:2009 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020","categories":["other"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"methodology_en":"Mechanical strength","search_en":"Mechanical strength Reference documents PN-EN 60947-7-1:2012 | IEC 60947-7-1:2009 | PN-EN 60947-7-2:2012 | IEC 60947-7-2:2009 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020"},{"_id":"6a7f0bb91995264369d8e2a1","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Listwy zaciskowe do przewodów miedzianych / Terminal blocks for copper conductors","methodology":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:","parameters":[{"name":"udarowym piorunowym do Up=25 kV / lightning impulse up to Up = 25 kV"},{"name":"przemiennym 50 Hz do Ud=5 kV / power frequency 50 Hz up to Ud = 5 kV"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=25 kV / lightning impulse up to Up = 25 kV\nprzemiennym 50 Hz do Ud=5 kV / power frequency 50 Hz up to Ud = 5 kV","reference":"PN-EN 60947-7-1:2012 | IEC 60947-7-1:2009 | PN-EN 60947-7-2:2012 | IEC 60947-7-2:2009 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020","norm_bases":["PN-EN 60947-7-1:2012","IEC 60947-7-1:2009","PN-EN 60947-7-2:2012","IEC 60947-7-2:2009","PN-EN IEC 60947-1:2021-07","IEC 60947-1:2020"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Listwy zaciskowe do przewodów miedzianych / Terminal blocks for copper conductors Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=25 kV / lightning impulse up to Up = 25 kV\nprzemiennym 50 Hz do Ud=5 kV / power frequency 50 Hz up to Ud = 5 kV PN-EN 60947-7-1:2012 | IEC 60947-7-1:2009 | PN-EN 60947-7-2:2012 | IEC 60947-7-2:2009 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 Listwy zaciskowe do przewodow miedzianych / Terminal blocks for copper conductors Wytrzymalosc elektryczna izolacji napieciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=25 kV / lightning impulse up to Up = 25 kV\nprzemiennym 50 Hz do Ud=5 kV / power frequency 50 Hz up to Ud = 5 kV PN-EN 60947-7-1:2012 | IEC 60947-7-1:2009 | PN-EN 60947-7-2:2012 | IEC 60947-7-2:2009 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020","categories":["construction"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN 60947-7-1:2012 | IEC 60947-7-1:2009 | PN-EN 60947-7-2:2012 | IEC 60947-7-2:2009 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020"},{"_id":"6a7f0bb91995264369d8e2a2","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Listwy zaciskowe do przewodów miedzianych / Terminal blocks for copper conductors","methodology":"Graniczne przyrosty temperatury / Temperature rise tests","parameters":[{"name":"Zakres / Range","range":"do 1 kA / up to and including 1 kA"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 1 kA / up to and including 1 kA","reference":"PN-EN 60947-7-1:2012 | IEC 60947-7-1:2009 | PN-EN 60947-7-2:2012 | IEC 60947-7-2:2009 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020","norm_bases":["PN-EN 60947-7-1:2012","IEC 60947-7-1:2009","PN-EN 60947-7-2:2012","IEC 60947-7-2:2009","PN-EN IEC 60947-1:2021-07","IEC 60947-1:2020"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Listwy zaciskowe do przewodów miedzianych / Terminal blocks for copper conductors Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 1 kA / up to and including 1 kA PN-EN 60947-7-1:2012 | IEC 60947-7-1:2009 | PN-EN 60947-7-2:2012 | IEC 60947-7-2:2009 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 Listwy zaciskowe do przewodow miedzianych / Terminal blocks for copper conductors Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 1 kA / up to and including 1 kA PN-EN 60947-7-1:2012 | IEC 60947-7-1:2009 | PN-EN 60947-7-2:2012 | IEC 60947-7-2:2009 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020","categories":["other"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 1 kA / up to and including 1 kA"}],"search_en":"Range Reference documents PN-EN 60947-7-1:2012 | IEC 60947-7-1:2009 | PN-EN 60947-7-2:2012 | IEC 60947-7-2:2009 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020","parameters_zh":[{"name":"范围 / Range","range":"do 1 kA / up to and including 1 kA"}],"search_zh":"范围 / Range PN-EN 60947-7-1:2012 | IEC 60947-7-1:2009 | PN-EN 60947-7-2:2012 | IEC 60947-7-2:2009 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020"},{"_id":"6a7f0bb91995264369d8e2a3","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Rozdzielnice i sterownice niskonapięciowe – ZESTAWY / Low-voltage switchgear and control gear assemblies","methodology":"Graniczne przyrosty temperatury / Temperature rise tests","parameters":[{"name":"Zakres / Range","range":"do 12 kA / up to and including 12 kA"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 12 kA / up to and including 12 kA","reference":"PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2012 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN IEC 61439-7:2020-10 | PN-EN IEC 61439-7:2024-04 | PN-E-05163:2002 | IEC/TR 61641:2014 | PN-EN IEC 62208:2024-04 | IEC 62208:2023","norm_bases":["PN-EN IEC 61439-1:2021-10","IEC 61439-1:2020","PN-EN IEC 61439-2:2021-10","IEC 61439-2:2020","PN-EN IEC 61439-3:2025-09","IEC 61439-3:2024","PN-EN 61439-4:2013-06","IEC 61439-4:2012","PN-EN IEC 61439-5:2024-04","IEC 61439-5:2023","PN-EN 61439-6:2013-03","IEC 61439-6:2012","PN-EN IEC 61439-7:2020-10","PN-EN IEC 61439-7:2024-04","PN-E-05163:2002","IEC/TR 61641:2014","PN-EN IEC 62208:2024-04","IEC 62208:2023"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Rozdzielnice i sterownice niskonapięciowe – ZESTAWY / Low-voltage switchgear and control gear assemblies Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 12 kA / up to and including 12 kA PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2012 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN IEC 61439-7:2020-10 | PN-EN IEC 61439-7:2024-04 | PN-E-05163:2002 | IEC/TR 61641:2014 | PN-EN IEC 62208:2024-04 | IEC 62208:2023 Rozdzielnice i sterownice niskonapieciowe – ZESTAWY / Low-voltage switchgear and control gear assemblies Graniczne przyrosty temperatury / Temperature rise tests\nZakres / Range do 12 kA / up to and including 12 kA PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2012 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN IEC 61439-7:2020-10 | PN-EN IEC 61439-7:2024-04 | PN-E-05163:2002 | IEC/TR 61641:2014 | PN-EN IEC 62208:2024-04 | IEC 62208:2023","categories":["other"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 12 kA / up to and including 12 kA"}],"search_en":"Range Reference documents PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2012 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN IEC 61439-7:2020-10 | PN-EN IEC 61439-7:2024-04 | PN-E-05163:2002 | IEC/TR 61641:2014 | PN-EN IEC 62208:2024-04 | IEC 62208:2023","parameters_zh":[{"name":"范围 / Range","range":"do 12 kA / up to and including 12 kA"}],"search_zh":"范围 / Range PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2012 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN IEC 61439-7:2020-10 | PN-EN IEC 61439-7:2024-04 | PN-E-05163:2002 | IEC/TR 61641:2014 | PN-EN IEC 62208:2024-04 | IEC 62208:2023"},{"_id":"6a7f0bb91995264369d8e2a4","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Rozdzielnice i sterownice niskonapięciowe – ZESTAWY / Low-voltage switchgear and control gear assemblies","methodology":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:","parameters":[{"name":"udarowym piorunowym do Up=25 kV / lightning impulse up to Up = 25 kV"},{"name":"przemiennym 50 Hz do Ud=15 kV / power frequency 50 Hz up to Ud = 15 kV"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=25 kV / lightning impulse up to Up = 25 kV\nprzemiennym 50 Hz do Ud=15 kV / power frequency 50 Hz up to Ud = 15 kV","reference":"PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2012 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN IEC 61439-7:2020-10 | PN-EN IEC 61439-7:2024-04 | PN-E-05163:2002 | IEC/TR 61641:2014 | PN-EN IEC 62208:2024-04 | IEC 62208:2023","norm_bases":["PN-EN IEC 61439-1:2021-10","IEC 61439-1:2020","PN-EN IEC 61439-2:2021-10","IEC 61439-2:2020","PN-EN IEC 61439-3:2025-09","IEC 61439-3:2024","PN-EN 61439-4:2013-06","IEC 61439-4:2012","PN-EN IEC 61439-5:2024-04","IEC 61439-5:2023","PN-EN 61439-6:2013-03","IEC 61439-6:2012","PN-EN IEC 61439-7:2020-10","PN-EN IEC 61439-7:2024-04","PN-E-05163:2002","IEC/TR 61641:2014","PN-EN IEC 62208:2024-04","IEC 62208:2023"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Rozdzielnice i sterownice niskonapięciowe – ZESTAWY / Low-voltage switchgear and control gear assemblies Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=25 kV / lightning impulse up to Up = 25 kV\nprzemiennym 50 Hz do Ud=15 kV / power frequency 50 Hz up to Ud = 15 kV PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2012 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN IEC 61439-7:2020-10 | PN-EN IEC 61439-7:2024-04 | PN-E-05163:2002 | IEC/TR 61641:2014 | PN-EN IEC 62208:2024-04 | IEC 62208:2023 Rozdzielnice i sterownice niskonapieciowe – ZESTAWY / Low-voltage switchgear and control gear assemblies Wytrzymalosc elektryczna izolacji napieciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=25 kV / lightning impulse up to Up = 25 kV\nprzemiennym 50 Hz do Ud=15 kV / power frequency 50 Hz up to Ud = 15 kV PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2012 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN IEC 61439-7:2020-10 | PN-EN IEC 61439-7:2024-04 | PN-E-05163:2002 | IEC/TR 61641:2014 | PN-EN IEC 62208:2024-04 | IEC 62208:2023","categories":["construction"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2012 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN IEC 61439-7:2020-10 | PN-EN IEC 61439-7:2024-04 | PN-E-05163:2002 | IEC/TR 61641:2014 | PN-EN IEC 62208:2024-04 | IEC 62208:2023"},{"_id":"6a7f0bb91995264369d8e2a5","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Rozdzielnice i sterownice niskonapięciowe – ZESTAWY / Low-voltage switchgear and control gear assemblies","methodology":"Wytrzymałość zwarciowa / Short-circuit tests","parameters":[{"name":"Zakres / Range","range":"do 120 kA rms / 250 kA peak / up to and including 120 kA rms / 250 kA peak"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość zwarciowa / Short-circuit tests\nZakres / Range do 120 kA rms / 250 kA peak / up to and including 120 kA rms / 250 kA peak","reference":"PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2012 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN IEC 61439-7:2020-10 | PN-EN IEC 61439-7:2024-04 | PN-E-05163:2002 | IEC/TR 61641:2014 | PN-EN IEC 62208:2024-04 | IEC 62208:2023","norm_bases":["PN-EN IEC 61439-1:2021-10","IEC 61439-1:2020","PN-EN IEC 61439-2:2021-10","IEC 61439-2:2020","PN-EN IEC 61439-3:2025-09","IEC 61439-3:2024","PN-EN 61439-4:2013-06","IEC 61439-4:2012","PN-EN IEC 61439-5:2024-04","IEC 61439-5:2023","PN-EN 61439-6:2013-03","IEC 61439-6:2012","PN-EN IEC 61439-7:2020-10","PN-EN IEC 61439-7:2024-04","PN-E-05163:2002","IEC/TR 61641:2014","PN-EN IEC 62208:2024-04","IEC 62208:2023"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Rozdzielnice i sterownice niskonapięciowe – ZESTAWY / Low-voltage switchgear and control gear assemblies Wytrzymałość zwarciowa / Short-circuit tests\nZakres / Range do 120 kA rms / 250 kA peak / up to and including 120 kA rms / 250 kA peak PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2012 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN IEC 61439-7:2020-10 | PN-EN IEC 61439-7:2024-04 | PN-E-05163:2002 | IEC/TR 61641:2014 | PN-EN IEC 62208:2024-04 | IEC 62208:2023 Rozdzielnice i sterownice niskonapieciowe – ZESTAWY / Low-voltage switchgear and control gear assemblies Wytrzymalosc zwarciowa / Short-circuit tests\nZakres / Range do 120 kA rms / 250 kA peak / up to and including 120 kA rms / 250 kA peak PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2012 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN IEC 61439-7:2020-10 | PN-EN IEC 61439-7:2024-04 | PN-E-05163:2002 | IEC/TR 61641:2014 | PN-EN IEC 62208:2024-04 | IEC 62208:2023","categories":["other"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 120 kA rms / 250 kA peak / up to and including 120 kA rms / 250 kA peak"}],"search_en":"Range Reference documents PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2012 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN IEC 61439-7:2020-10 | PN-EN IEC 61439-7:2024-04 | PN-E-05163:2002 | IEC/TR 61641:2014 | PN-EN IEC 62208:2024-04 | IEC 62208:2023","parameters_zh":[{"name":"范围 / Range","range":"do 120 kA rms / 250 kA peak / up to and including 120 kA rms / 250 kA peak"}],"search_zh":"范围 / Range PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2012 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN IEC 61439-7:2020-10 | PN-EN IEC 61439-7:2024-04 | PN-E-05163:2002 | IEC/TR 61641:2014 | PN-EN IEC 62208:2024-04 | IEC 62208:2023"},{"_id":"6a7f0bb91995264369d8e2a6","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Rozdzielnice i sterownice niskonapięciowe – ZESTAWY / Low-voltage switchgear and control gear assemblies","methodology":"Odporność na działanie łuku elektrycznego / Internal arc fault tests","parameters":[{"name":"Zakres / Range","range":"do 60 kA / up to and including 60 kA"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Odporność na działanie łuku elektrycznego / Internal arc fault tests\nZakres / Range do 60 kA / up to and including 60 kA","reference":"PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2012 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN IEC 61439-7:2020-10 | PN-EN IEC 61439-7:2024-04 | PN-E-05163:2002 | IEC/TR 61641:2014 | PN-EN IEC 62208:2024-04 | IEC 62208:2023","norm_bases":["PN-EN IEC 61439-1:2021-10","IEC 61439-1:2020","PN-EN IEC 61439-2:2021-10","IEC 61439-2:2020","PN-EN IEC 61439-3:2025-09","IEC 61439-3:2024","PN-EN 61439-4:2013-06","IEC 61439-4:2012","PN-EN IEC 61439-5:2024-04","IEC 61439-5:2023","PN-EN 61439-6:2013-03","IEC 61439-6:2012","PN-EN IEC 61439-7:2020-10","PN-EN IEC 61439-7:2024-04","PN-E-05163:2002","IEC/TR 61641:2014","PN-EN IEC 62208:2024-04","IEC 62208:2023"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Rozdzielnice i sterownice niskonapięciowe – ZESTAWY / Low-voltage switchgear and control gear assemblies Odporność na działanie łuku elektrycznego / Internal arc fault tests\nZakres / Range do 60 kA / up to and including 60 kA PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2012 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN IEC 61439-7:2020-10 | PN-EN IEC 61439-7:2024-04 | PN-E-05163:2002 | IEC/TR 61641:2014 | PN-EN IEC 62208:2024-04 | IEC 62208:2023 Rozdzielnice i sterownice niskonapieciowe – ZESTAWY / Low-voltage switchgear and control gear assemblies Odpornosc na dzialanie luku elektrycznego / Internal arc fault tests\nZakres / Range do 60 kA / up to and including 60 kA PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2012 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN IEC 61439-7:2020-10 | PN-EN IEC 61439-7:2024-04 | PN-E-05163:2002 | IEC/TR 61641:2014 | PN-EN IEC 62208:2024-04 | IEC 62208:2023","categories":["other"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"do 60 kA / up to and including 60 kA"}],"search_en":"Range Reference documents PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2012 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN IEC 61439-7:2020-10 | PN-EN IEC 61439-7:2024-04 | PN-E-05163:2002 | IEC/TR 61641:2014 | PN-EN IEC 62208:2024-04 | IEC 62208:2023","parameters_zh":[{"name":"范围 / Range","range":"do 60 kA / up to and including 60 kA"}],"search_zh":"范围 / Range PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2012 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN IEC 61439-7:2020-10 | PN-EN IEC 61439-7:2024-04 | PN-E-05163:2002 | IEC/TR 61641:2014 | PN-EN IEC 62208:2024-04 | IEC 62208:2023"},{"_id":"6a7f0bb91995264369d8e2a7","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Rozdzielnice i sterownice niskonapięciowe – ZESTAWY / Low-voltage switchgear and control gear assemblies","methodology":"Odstępy izolacyjne powietrzne i powierzchniowe / Clearances and creepage distances","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Odstępy izolacyjne powietrzne i powierzchniowe / Clearances and creepage distances","reference":"PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2012 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN IEC 61439-7:2020-10 | PN-EN IEC 61439-7:2024-04 | PN-E-05163:2002 | IEC/TR 61641:2014 | PN-EN IEC 62208:2024-04 | IEC 62208:2023","norm_bases":["PN-EN IEC 61439-1:2021-10","IEC 61439-1:2020","PN-EN IEC 61439-2:2021-10","IEC 61439-2:2020","PN-EN IEC 61439-3:2025-09","IEC 61439-3:2024","PN-EN 61439-4:2013-06","IEC 61439-4:2012","PN-EN IEC 61439-5:2024-04","IEC 61439-5:2023","PN-EN 61439-6:2013-03","IEC 61439-6:2012","PN-EN IEC 61439-7:2020-10","PN-EN IEC 61439-7:2024-04","PN-E-05163:2002","IEC/TR 61641:2014","PN-EN IEC 62208:2024-04","IEC 62208:2023"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Rozdzielnice i sterownice niskonapięciowe – ZESTAWY / Low-voltage switchgear and control gear assemblies Odstępy izolacyjne powietrzne i powierzchniowe / Clearances and creepage distances PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2012 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN IEC 61439-7:2020-10 | PN-EN IEC 61439-7:2024-04 | PN-E-05163:2002 | IEC/TR 61641:2014 | PN-EN IEC 62208:2024-04 | IEC 62208:2023 Rozdzielnice i sterownice niskonapieciowe – ZESTAWY / Low-voltage switchgear and control gear assemblies Odstepy izolacyjne powietrzne i powierzchniowe / Clearances and creepage distances PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2012 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN IEC 61439-7:2020-10 | PN-EN IEC 61439-7:2024-04 | PN-E-05163:2002 | IEC/TR 61641:2014 | PN-EN IEC 62208:2024-04 | IEC 62208:2023","categories":["construction"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2012 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN IEC 61439-7:2020-10 | PN-EN IEC 61439-7:2024-04 | PN-E-05163:2002 | IEC/TR 61641:2014 | PN-EN IEC 62208:2024-04 | IEC 62208:2023"},{"_id":"6a7f0bb91995264369d8e2a8","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Rozdzielnice i sterownice niskonapięciowe – ZESTAWY / Low-voltage switchgear and control gear assemblies","methodology":"Ochrona przed niezamierzonym dotykiem bezpośrednim części niebezpiecznych czynnych / Protection against unintentional direct contact with hazardous live parts","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Ochrona przed niezamierzonym dotykiem bezpośrednim części niebezpiecznych czynnych / Protection against unintentional direct contact with hazardous live parts","reference":"PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2012 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN IEC 61439-7:2020-10 | PN-EN IEC 61439-7:2024-04 | PN-E-05163:2002 | IEC/TR 61641:2014 | PN-EN IEC 62208:2024-04 | IEC 62208:2023","norm_bases":["PN-EN IEC 61439-1:2021-10","IEC 61439-1:2020","PN-EN IEC 61439-2:2021-10","IEC 61439-2:2020","PN-EN IEC 61439-3:2025-09","IEC 61439-3:2024","PN-EN 61439-4:2013-06","IEC 61439-4:2012","PN-EN IEC 61439-5:2024-04","IEC 61439-5:2023","PN-EN 61439-6:2013-03","IEC 61439-6:2012","PN-EN IEC 61439-7:2020-10","PN-EN IEC 61439-7:2024-04","PN-E-05163:2002","IEC/TR 61641:2014","PN-EN IEC 62208:2024-04","IEC 62208:2023"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Rozdzielnice i sterownice niskonapięciowe – ZESTAWY / Low-voltage switchgear and control gear assemblies Ochrona przed niezamierzonym dotykiem bezpośrednim części niebezpiecznych czynnych / Protection against unintentional direct contact with hazardous live parts PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2012 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN IEC 61439-7:2020-10 | PN-EN IEC 61439-7:2024-04 | PN-E-05163:2002 | IEC/TR 61641:2014 | PN-EN IEC 62208:2024-04 | IEC 62208:2023 Rozdzielnice i sterownice niskonapieciowe – ZESTAWY / Low-voltage switchgear and control gear assemblies Ochrona przed niezamierzonym dotykiem bezposrednim czesci niebezpiecznych czynnych / Protection against unintentional direct contact with hazardous live parts PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2012 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN IEC 61439-7:2020-10 | PN-EN IEC 61439-7:2024-04 | PN-E-05163:2002 | IEC/TR 61641:2014 | PN-EN IEC 62208:2024-04 | IEC 62208:2023","categories":["other"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2012 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN IEC 61439-7:2020-10 | PN-EN IEC 61439-7:2024-04 | PN-E-05163:2002 | IEC/TR 61641:2014 | PN-EN IEC 62208:2024-04 | IEC 62208:2023"},{"_id":"6a7f0bb91995264369d8e2a9","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Rozdzielnice i sterownice niskonapięciowe – ZESTAWY / Low-voltage switchgear and control gear assemblies","methodology":"Podnoszenie / Lifting","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Podnoszenie / Lifting","reference":"PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2012 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN IEC 61439-7:2020-10 | PN-EN IEC 61439-7:2024-04 | PN-E-05163:2002 | IEC/TR 61641:2014 | PN-EN IEC 62208:2024-04 | IEC 62208:2023","norm_bases":["PN-EN IEC 61439-1:2021-10","IEC 61439-1:2020","PN-EN IEC 61439-2:2021-10","IEC 61439-2:2020","PN-EN IEC 61439-3:2025-09","IEC 61439-3:2024","PN-EN 61439-4:2013-06","IEC 61439-4:2012","PN-EN IEC 61439-5:2024-04","IEC 61439-5:2023","PN-EN 61439-6:2013-03","IEC 61439-6:2012","PN-EN IEC 61439-7:2020-10","PN-EN IEC 61439-7:2024-04","PN-E-05163:2002","IEC/TR 61641:2014","PN-EN IEC 62208:2024-04","IEC 62208:2023"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Rozdzielnice i sterownice niskonapięciowe – ZESTAWY / Low-voltage switchgear and control gear assemblies Podnoszenie / Lifting PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2012 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN IEC 61439-7:2020-10 | PN-EN IEC 61439-7:2024-04 | PN-E-05163:2002 | IEC/TR 61641:2014 | PN-EN IEC 62208:2024-04 | IEC 62208:2023 Rozdzielnice i sterownice niskonapieciowe – ZESTAWY / Low-voltage switchgear and control gear assemblies Podnoszenie / Lifting PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2012 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN IEC 61439-7:2020-10 | PN-EN IEC 61439-7:2024-04 | PN-E-05163:2002 | IEC/TR 61641:2014 | PN-EN IEC 62208:2024-04 | IEC 62208:2023","categories":["other"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2012 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN IEC 61439-7:2020-10 | PN-EN IEC 61439-7:2024-04 | PN-E-05163:2002 | IEC/TR 61641:2014 | PN-EN IEC 62208:2024-04 | IEC 62208:2023"},{"_id":"6a7f0bb91995264369d8e2aa","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Obudowy urządzeń elektrycznych / Enclosures for electrical equipment, Urządzenia elektryczne i elektroniczne / Electrical and electronic equipment","methodology":"Stopień ochrony przed zewnętrznymi uderzeniami mechanicznymi IK do IK10 / Environmental testing - Test Eh: Hammer tests","parameters":[{"name":"Range","range":"up to IK10"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Stopień ochrony przed zewnętrznymi uderzeniami mechanicznymi IK do IK10 / Environmental testing - Test Eh: Hammer tests\nRange up to IK10","reference":"PN-EN 62262:2003 | PN-EN 60068-2-75:2015-01","norm_bases":["PN-EN 62262:2003","PN-EN 60068-2-75:2015-01"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Obudowy urządzeń elektrycznych / Enclosures for electrical equipment, Urządzenia elektryczne i elektroniczne / Electrical and electronic equipment Stopień ochrony przed zewnętrznymi uderzeniami mechanicznymi IK do IK10 / Environmental testing - Test Eh: Hammer tests\nRange up to IK10 PN-EN 62262:2003 | PN-EN 60068-2-75:2015-01 Obudowy urzadzen elektrycznych / Enclosures for electrical equipment, Urzadzenia elektryczne i elektroniczne / Electrical and electronic equipment Stopien ochrony przed zewnetrznymi uderzeniami mechanicznymi IK do IK10 / Environmental testing - Test Eh: Hammer tests\nRange up to IK10 PN-EN 62262:2003 | PN-EN 60068-2-75:2015-01","categories":["environment","electronics"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"up to IK10"}],"search_en":"Range Reference documents PN-EN 62262:2003 | PN-EN 60068-2-75:2015-01","parameters_zh":[{"name":"范围","range":"up to IK10"}],"search_zh":"范围 PN-EN 62262:2003 | PN-EN 60068-2-75:2015-01"},{"_id":"6a7f0bb91995264369d8e2ab","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Obudowy urządzeń elektrycznych / Enclosures for electrical equipment, Urządzenia elektryczne i elektroniczne / Electrical and electronic equipment","methodology":"Badania środowiskowe – Próba: A Zimno / Environmental testing - Test A: Cold","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Badania środowiskowe – Próba: A Zimno / Environmental testing - Test A: Cold","reference":"PN-EN 60068-2-1:2009","norm_bases":["PN-EN 60068-2-1:2009"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Obudowy urządzeń elektrycznych / Enclosures for electrical equipment, Urządzenia elektryczne i elektroniczne / Electrical and electronic equipment Badania środowiskowe – Próba: A Zimno / Environmental testing - Test A: Cold PN-EN 60068-2-1:2009 Obudowy urzadzen elektrycznych / Enclosures for electrical equipment, Urzadzenia elektryczne i elektroniczne / Electrical and electronic equipment Badania srodowiskowe – Proba: A Zimno / Environmental testing - Test A: Cold PN-EN 60068-2-1:2009","categories":["environment","electronics"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN 60068-2-1:2009"},{"_id":"6a7f0bb91995264369d8e2ac","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Obudowy urządzeń elektrycznych / Enclosures for electrical equipment, Urządzenia elektryczne i elektroniczne / Electrical and electronic equipment","methodology":"Badania środowiskowe – Próba: B Suche gorąco / Environmental testing - Test B: Dry heat","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Badania środowiskowe – Próba: B Suche gorąco / Environmental testing - Test B: Dry heat","reference":"PN-EN 60068-2-2:2009","norm_bases":["PN-EN 60068-2-2:2009"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Obudowy urządzeń elektrycznych / Enclosures for electrical equipment, Urządzenia elektryczne i elektroniczne / Electrical and electronic equipment Badania środowiskowe – Próba: B Suche gorąco / Environmental testing - Test B: Dry heat PN-EN 60068-2-2:2009 Obudowy urzadzen elektrycznych / Enclosures for electrical equipment, Urzadzenia elektryczne i elektroniczne / Electrical and electronic equipment Badania srodowiskowe – Proba: B Suche goraco / Environmental testing - Test B: Dry heat PN-EN 60068-2-2:2009","categories":["environment","electronics"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN 60068-2-2:2009"},{"_id":"6a7f0bb91995264369d8e2ad","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Obudowy urządzeń elektrycznych / Enclosures for electrical equipment, Urządzenia elektryczne i elektroniczne / Electrical and electronic equipment","methodology":"Badania środowiskowe – Próba: Cab Wilgotne gorąco stałe / Environmental testing - Test Cab: Damp heat, steady state","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Badania środowiskowe – Próba: Cab Wilgotne gorąco stałe / Environmental testing - Test Cab: Damp heat, steady state","reference":"PN-EN 60068-2-78:2013-11","norm_bases":["PN-EN 60068-2-78:2013-11"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Obudowy urządzeń elektrycznych / Enclosures for electrical equipment, Urządzenia elektryczne i elektroniczne / Electrical and electronic equipment Badania środowiskowe – Próba: Cab Wilgotne gorąco stałe / Environmental testing - Test Cab: Damp heat, steady state PN-EN 60068-2-78:2013-11 Obudowy urzadzen elektrycznych / Enclosures for electrical equipment, Urzadzenia elektryczne i elektroniczne / Electrical and electronic equipment Badania srodowiskowe – Proba: Cab Wilgotne goraco stale / Environmental testing - Test Cab: Damp heat, steady state PN-EN 60068-2-78:2013-11","categories":["environment","electronics"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN 60068-2-78:2013-11"},{"_id":"6a7f0bb91995264369d8e2ae","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Obudowy urządzeń elektrycznych / Enclosures for electrical equipment, Urządzenia elektryczne i elektroniczne / Electrical and electronic equipment","methodology":"Badania środowiskowe – Próba: Db Wilgotne gorąco cykliczne / Environmental testing - Test Db: Damp heat, cyclic","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Badania środowiskowe – Próba: Db Wilgotne gorąco cykliczne / Environmental testing - Test Db: Damp heat, cyclic","reference":"PN-EN 60068-2-30:2008","norm_bases":["PN-EN 60068-2-30:2008"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Obudowy urządzeń elektrycznych / Enclosures for electrical equipment, Urządzenia elektryczne i elektroniczne / Electrical and electronic equipment Badania środowiskowe – Próba: Db Wilgotne gorąco cykliczne / Environmental testing - Test Db: Damp heat, cyclic PN-EN 60068-2-30:2008 Obudowy urzadzen elektrycznych / Enclosures for electrical equipment, Urzadzenia elektryczne i elektroniczne / Electrical and electronic equipment Badania srodowiskowe – Proba: Db Wilgotne goraco cykliczne / Environmental testing - Test Db: Damp heat, cyclic PN-EN 60068-2-30:2008","categories":["environment","electronics"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN 60068-2-30:2008"},{"_id":"6a7f0bb91995264369d8e2af","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Obudowy urządzeń elektrycznych / Enclosures for electrical equipment, Urządzenia elektryczne i elektroniczne / Electrical and electronic equipment","methodology":"Odporność na korozję w atmosferze mgły solnej / Resistance to corrosion in a salt mist atmosphere","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Odporność na korozję w atmosferze mgły solnej / Resistance to corrosion in a salt mist atmosphere","reference":"PN-EN IEC 60068-2-11:2021-11 | PN-EN 60068-2-52:2018-05","norm_bases":["PN-EN IEC 60068-2-11:2021-11","PN-EN 60068-2-52:2018-05"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Obudowy urządzeń elektrycznych / Enclosures for electrical equipment, Urządzenia elektryczne i elektroniczne / Electrical and electronic equipment Odporność na korozję w atmosferze mgły solnej / Resistance to corrosion in a salt mist atmosphere PN-EN IEC 60068-2-11:2021-11 | PN-EN 60068-2-52:2018-05 Obudowy urzadzen elektrycznych / Enclosures for electrical equipment, Urzadzenia elektryczne i elektroniczne / Electrical and electronic equipment Odpornosc na korozje w atmosferze mgly solnej / Resistance to corrosion in a salt mist atmosphere PN-EN IEC 60068-2-11:2021-11 | PN-EN 60068-2-52:2018-05","categories":["electronics"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN IEC 60068-2-11:2021-11 | PN-EN 60068-2-52:2018-05"},{"_id":"6a7f0bb91995264369d8e2b0","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Obudowy urządzeń elektrycznych / Enclosures for electrical equipment, Urządzenia elektryczne i elektroniczne / Electrical and electronic equipment","methodology":"Stopień ochrony do IP 68 / Degree of protection up to IP 68","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Stopień ochrony do IP 68 / Degree of protection up to IP 68","reference":"PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 z wyłączeniem punktu 14 | IEC 60529:1989 | IEC 60529:1989/AMD 1:1989 | IEC 60529:1989/AMD 2:2013 z wyłączeniem punktu 14","norm_bases":["PN-EN 60529:2003","PN-EN 60529:2003/A2:2014-07 z wyłączeniem punktu 14","IEC 60529:1989","IEC 60529:1989/AMD 1:1989","IEC 60529:1989/AMD 2:2013 z wyłączeniem punktu 14"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Obudowy urządzeń elektrycznych / Enclosures for electrical equipment, Urządzenia elektryczne i elektroniczne / Electrical and electronic equipment Stopień ochrony do IP 68 / Degree of protection up to IP 68 PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 z wyłączeniem punktu 14 | IEC 60529:1989 | IEC 60529:1989/AMD 1:1989 | IEC 60529:1989/AMD 2:2013 z wyłączeniem punktu 14 Obudowy urzadzen elektrycznych / Enclosures for electrical equipment, Urzadzenia elektryczne i elektroniczne / Electrical and electronic equipment Stopien ochrony do IP 68 / Degree of protection up to IP 68 PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 z wylaczeniem punktu 14 | IEC 60529:1989 | IEC 60529:1989/AMD 1:1989 | IEC 60529:1989/AMD 2:2013 z wylaczeniem punktu 14","categories":["electronics"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 z wyłączeniem punktu 14 | IEC 60529:1989 | IEC 60529:1989/AMD 1:1989 | IEC 60529:1989/AMD 2:2013 z wyłączeniem punktu 14"},{"_id":"6a7f0bb91995264369d8e2b1","lab_id":"69ad52a3de79e566650fb0ff","country":"PL","accr_number":"AB 074","accr_body":"PCA","test_object":"Obudowy urządzeń elektrycznych / Enclosures for electrical equipment, Urządzenia elektryczne i elektroniczne / Electrical and electronic equipment","methodology":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:","parameters":[{"name":"udarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV"},{"name":"udarowym łączeniowym do Up=900 kV / switching impulse up to Up=900 kV"},{"name":"przemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nudarowym łączeniowym do Up=900 kV / switching impulse up to Up=900 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV","reference":"PN-EN 60060-1:2011 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | IEC 60060-2:2010","norm_bases":["PN-EN 60060-1:2011","IEC 60060-1:2010","PN-EN 60060-2:2011","IEC 60060-2:2010"],"lab_section":"Laboratorium Badawcze Aparatury Elektroenergetycznej (LAE); High Power Equipment Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Obudowy urządzeń elektrycznych / Enclosures for electrical equipment, Urządzenia elektryczne i elektroniczne / Electrical and electronic equipment Wytrzymałość elektryczna izolacji napięciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nudarowym łączeniowym do Up=900 kV / switching impulse up to Up=900 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV PN-EN 60060-1:2011 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | IEC 60060-2:2010 Obudowy urzadzen elektrycznych / Enclosures for electrical equipment, Urzadzenia elektryczne i elektroniczne / Electrical and electronic equipment Wytrzymalosc elektryczna izolacji napieciem / Impulse voltage withstand test:\nZakres:\nudarowym piorunowym do Up=1200 kV / lightning impulse up to Up = 1200 kV\nudarowym laczeniowym do Up=900 kV / switching impulse up to Up=900 kV\nprzemiennym 50 Hz do Ud=300 kV / power frequency 50 Hz up to Ud = 300 kV PN-EN 60060-1:2011 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | IEC 60060-2:2010","categories":["electronics","construction"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/ metoda / Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Reference documents PN-EN 60060-1:2011 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | IEC 60060-2:2010"}],"has_pdf":true}