{"lab":{"_id":"69ad52a3de79e566650fb0fd","accr_number":"AB 073","country":"PL","accr_body":"PCA","address":"- INSTYTUT METALI NIEŻELAZNYCH, CENTRUM OCHRONY ŚRODOWISKA, ul. Sowińskiego 5, 44-100 Gliwice","categories":["environment","materials"],"city":"Gliwice","imported_at":"2026-03-08T10:42:43.265Z","methods_count":26,"name":"SIEĆ BADAWCZA ŁUKASIEWICZ","parse_status":"parsed","parse_version":3,"pdf_files":["AB_073.pdf"],"scope_summary":"","search_text":"sieć badawcza łukasiewicz - instytut metali nieżelaznych, centrum ochrony środowiska, ul. sowińskiego 5, 44-100 gliwice environment metrology other materials","status":"active","updated_at":"2026-03-08T14:50:08.149Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:08.149Z","parse_date":"2026-07-18T08:36:04.817Z","parse_source":"m5-mistral-qa","email_confidence":"high","email_mx":true,"email_source":"https://imn.lukasiewicz.gov.pl/kontakt","fields_of_testing":[{"codes":"C/36/P","pl":"Badania chemiczne i pobieranie próbek gazów odlotowych","en":"Chemical tests and sampling of waste gases"},{"codes":"G/36","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – gazy (gazy odlotowe)","en":"Tests concerning environmental engineering (environmental and climatic) – gases (waste gases)"},{"codes":"M/39","pl":"Badania inne - urządzenia ochrony powietrza","en":"Other tests - air protection equipment"},{"codes":"N/36/P","pl":"Badania właściwości fizycznych i pobieranie próbek gazów odlotowych","en":"Tests of physical properties and sampling of waste gases"},{"codes":"P/36","pl":"Pobieranie próbek gazów odlotowych","en":"Sampling of waste gases"}],"issue":{"no":"27","date":"29.01.2026"},"map_coord":[50.295789,18.633954],"map_geo":"nominatim-street","has_en":true,"category_counts":{"other":14,"environment":10,"materials":4},"category_scores":{"other":7,"environment":3.57,"materials":0.57},"has_zh":true},"methods":[{"_id":"6a5b3af482c33e0ee4095232","lab_id":"69ad52a3de79e566650fb0fd","country":"PL","accr_number":"AB 073","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Strumień objętości gazu dla ciśnień dynamicznych","methodology_en":"Gas volume flow rate for dynamic pressures","parameters":[],"parameters_en":[],"technique":"Metoda spiętrzeniowa","techniques":["Metoda spiętrzeniowa"],"technique_en":"Stagnation pressure method","computed":[],"computed_en":[],"activity":"Strumień objętości gazu dla ciśnień dynamicznych\nMetoda spiętrzeniowa","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Strumień objętości gazu dla ciśnień dynamicznych\nMetoda spiętrzeniowa PN-Z-04030-7:1994 Gazy odlotowe Strumien objetosci gazu dla cisnien dynamicznych\nMetoda spietrzeniowa PN-Z-04030-7:1994","categories":["other"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Gas volume flow rate for dynamic pressures Stagnation pressure method PN-Z-04030-7:1994","search_zh":"废气 PN-Z-04030-7:1994","test_object_zh":"废气"},{"_id":"6a5b3af482c33e0ee4095233","lab_id":"69ad52a3de79e566650fb0fd","country":"PL","accr_number":"AB 073","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","methodology_en":"Sampling for determination of dust concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-EN 13284-1:2018-02 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-EN 13284-1:2018-02","categories":["other"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of dust concentration PN-EN 13284-1:2018-02","search_zh":"废气 粉尘浓度测定采样 PN-EN 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样"},{"_id":"6a5b3af482c33e0ee4095234","lab_id":"69ad52a3de79e566650fb0fd","country":"PL","accr_number":"AB 073","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pyłu","methodology_en":"Dust concentration","parameters":[{"name":"Stężenie pyłu","range":"(0,001 – 10) g/m3"}],"parameters_en":[{"name":"Dust concentration","range":"(0,001 – 10) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłu\nZakres: (0,001 – 10) g/m3\nMetoda grawimetryczna","reference":"PN-EN ISO 16911-1:2013-07 + CEN/TR 17078:2017","norm_bases":["PN-EN ISO 16911-1:2013-07 + CEN/TR 17078:2017"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres: (0,001 – 10) g/m3\nMetoda grawimetryczna PN-EN ISO 16911-1:2013-07 + CEN/TR 17078:2017 Gazy odlotowe Stezenie pylu\nZakres: (0,001 – 10) g/m3\nMetoda grawimetryczna PN-EN ISO 16911-1:2013-07 + CEN/TR 17078:2017","categories":["other"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Dust concentration Gravimetric method Dust concentration PN-EN ISO 16911-1:2013-07 + CEN/TR 17078:2017","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"粉尘浓度","range":"(0,001 – 10) g/m3"}],"search_zh":"废气 粉尘浓度 重量法 粉尘浓度 PN-EN ISO 16911-1:2013-07 + CEN/TR 17078:2017","technique_zh":"重量法","test_object_zh":"废气"},{"_id":"6a5b3af482c33e0ee4095235","lab_id":"69ad52a3de79e566650fb0fd","country":"PL","accr_number":"AB 073","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja pyłu (z obliczeń)","methodology_en":"Dust emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja pyłu (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) Gazy odlotowe Emisja pylu (z obliczen)","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Dust emission (calculated)","search_zh":"废气 粉尘排放量（计算值）","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a5b3af482c33e0ee4095236","lab_id":"69ad52a3de79e566650fb0fd","country":"PL","accr_number":"AB 073","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Prędkość i strumień objętości gazu dla ciśnień różnicowych","methodology_en":"Gas velocity and volume flow for differential pressures","parameters":[],"parameters_en":[],"technique":"Metoda pomiaru ciśnienia różnicowego","techniques":["Metoda pomiaru ciśnienia różnicowego"],"technique_en":"Differential pressure measurement method","computed":[],"computed_en":[],"activity":"Prędkość i strumień objętości gazu dla ciśnień różnicowych\nMetoda pomiaru ciśnienia różnicowego","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Prędkość i strumień objętości gazu dla ciśnień różnicowych\nMetoda pomiaru ciśnienia różnicowego PN-ISO 10396:2001 Gazy odlotowe Predkosc i strumien objetosci gazu dla cisnien roznicowych\nMetoda pomiaru cisnienia roznicowego PN-ISO 10396:2001","categories":["other"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Gas velocity and volume flow for differential pressures Differential pressure measurement method PN-ISO 10396:2001","search_zh":"废气 差压测量法 PN-ISO 10396:2001","test_object_zh":"废气","technique_zh":"差压测量法"},{"_id":"6a5b3af482c33e0ee4095237","lab_id":"69ad52a3de79e566650fb0fd","country":"PL","accr_number":"AB 073","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenu","methodology_en":"Oxygen concentration","parameters":[{"name":"Stężenie tlenu","range":"(3,0 – 21) %"}],"parameters_en":[{"name":"Oxygen concentration","range":"(3,0 – 21) %"}],"technique":"Metoda paramagnetyczna (PMD)","techniques":["Metoda paramagnetyczna (PMD)"],"technique_en":"Paramagnetic method (PMD)","computed":[],"computed_en":[],"activity":"Stężenie tlenu\nZakres: (3,0 – 21) %\nMetoda paramagnetyczna (PMD)","reference":"PN-EN 14789:2017-04","norm_bases":["PN-EN 14789:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenu\nZakres: (3,0 – 21) %\nMetoda paramagnetyczna (PMD) PN-EN 14789:2017-04 Gazy odlotowe Stezenie tlenu\nZakres: (3,0 – 21) %\nMetoda paramagnetyczna (PMD) PN-EN 14789:2017-04","categories":["other"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Oxygen concentration Paramagnetic method (PMD) Oxygen concentration PN-EN 14789:2017-04","search_zh":"废气 氧浓度 顺磁法（PMD） 氧浓度 PN-EN 14789:2017-04","test_object_zh":"废气","methodology_zh":"氧浓度","parameters_zh":[{"name":"氧浓度","range":"(3,0 – 21) %"}],"technique_zh":"顺磁法（PMD）"},{"_id":"6a5b3af482c33e0ee4095238","lab_id":"69ad52a3de79e566650fb0fd","country":"PL","accr_number":"AB 073","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie dwutlenku węgla, dwutlenku siarki, tlenku węgla","methodology_en":"Concentration of carbon dioxide, sulphur dioxide, carbon monoxide","parameters":[{"name":"Stężenie CO","range":"(0,10 – 16) %"},{"name":"Stężenie CO","range":"(5 – 1250) mg/m3"},{"name":"Stężenie SO","range":"(8,30 – 6000) mg/m3"}],"parameters_en":[{"name":"CO concentration","range":"(0,10 – 16) %"},{"name":"CO concentration","range":"(5 – 1250) mg/m3"},{"name":"SO concentration","range":"(8,30 – 6000) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"technique_en":"Non-dispersive infrared spectrometry (NDIR)","computed":[],"computed_en":[],"activity":"Stężenie dwutlenku węgla, dwutlenku siarki, tlenku węgla\nZakres:\nStężenie CO (0,10 – 16) %\nStężenie CO (5 – 1250) mg/m3\nStężenie SO (8,30 – 6000) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie dwutlenku węgla, dwutlenku siarki, tlenku węgla\nZakres:\nStężenie CO (0,10 – 16) %\nStężenie CO (5 – 1250) mg/m3\nStężenie SO (8,30 – 6000) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001 Gazy odlotowe Stezenie dwutlenku wegla, dwutlenku siarki, tlenku wegla\nZakres:\nStezenie CO (0,10 – 16) %\nStezenie CO (5 – 1250) mg/m3\nStezenie SO (8,30 – 6000) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001","categories":["other"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Concentration of carbon dioxide, sulphur dioxide, carbon monoxide Non-dispersive infrared spectrometry (NDIR) CO concentration CO concentration SO concentration PN-ISO 10396:2001","search_zh":"废气 二氧化碳、二氧化硫、一氧化碳浓度 非分散红外光谱法（NDIR） CO 浓度 CO 浓度 PN-ISO 10396:2001","test_object_zh":"废气","technique_zh":"非分散红外光谱法（NDIR）","parameters_zh":[{"name":"CO 浓度","range":"(0,10 – 16) %"},{"name":"CO 浓度","range":"(5 – 1250) mg/m3"},{"name":"Stężenie SO","range":"(8,30 – 6000) mg/m3"}],"methodology_zh":"二氧化碳、二氧化硫、一氧化碳浓度"},{"_id":"6a5b3af482c33e0ee4095239","lab_id":"69ad52a3de79e566650fb0fd","country":"PL","accr_number":"AB 073","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja CO, SO, CO2 (z obliczeń)","methodology_en":"Emission of CO, SO, CO2 (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja CO, SO, CO2 (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja CO, SO, CO2 (z obliczeń) Gazy odlotowe Emisja CO, SO, CO2 (z obliczen)","categories":["environment"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of CO, SO, CO2 (calculated)","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5b3af482c33e0ee409523a","lab_id":"69ad52a3de79e566650fb0fd","country":"PL","accr_number":"AB 073","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenku azotu, tlenków azotu","methodology_en":"Concentration of nitrogen monoxide, nitrogen oxides","parameters":[{"name":"Stężenie NO","range":"(5,4 – 1340) mg/m3"},{"name":"Stężenie NO","range":"(8,2 – 2050) mg/m3"}],"parameters_en":[{"name":"NO concentration","range":"(5,4 – 1340) mg/m3"},{"name":"NO concentration","range":"(8,2 – 2050) mg/m3"}],"technique":"Metoda chemiluminescencyjna (CLD)","techniques":["Metoda chemiluminescencyjna (CLD)"],"technique_en":"Chemiluminescence method (CLD)","computed":[],"computed_en":[],"activity":"Stężenie tlenku azotu, tlenków azotu\nZakres:\nStężenie NO (5,4 – 1340) mg/m3\nStężenie NO (8,2 – 2050) mg/m3\nMetoda chemiluminescencyjna (CLD)","reference":"PN-EN 14792:2017-04","norm_bases":["PN-EN 14792:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenku azotu, tlenków azotu\nZakres:\nStężenie NO (5,4 – 1340) mg/m3\nStężenie NO (8,2 – 2050) mg/m3\nMetoda chemiluminescencyjna (CLD) PN-EN 14792:2017-04 Gazy odlotowe Stezenie tlenku azotu, tlenkow azotu\nZakres:\nStezenie NO (5,4 – 1340) mg/m3\nStezenie NO (8,2 – 2050) mg/m3\nMetoda chemiluminescencyjna (CLD) PN-EN 14792:2017-04","categories":["other"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Concentration of nitrogen monoxide, nitrogen oxides Chemiluminescence method (CLD) NO concentration NO concentration PN-EN 14792:2017-04","search_zh":"废气 一氧化氮、氮氧化物浓度 化学发光法（CLD） NO 浓度 NO 浓度 PN-EN 14792:2017-04","test_object_zh":"废气","technique_zh":"化学发光法（CLD）","methodology_zh":"一氧化氮、氮氧化物浓度","parameters_zh":[{"name":"NO 浓度","range":"(5,4 – 1340) mg/m3"},{"name":"NO 浓度","range":"(8,2 – 2050) mg/m3"}]},{"_id":"6a5b3af482c33e0ee409523b","lab_id":"69ad52a3de79e566650fb0fd","country":"PL","accr_number":"AB 073","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja NO, NO (NO w przeliczeniu na NO) (z obliczeń)","methodology_en":"Emission of NO, NO (NO calculated as NO) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja NO, NO (NO w przeliczeniu na NO) (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja NO, NO (NO w przeliczeniu na NO) (z obliczeń) Gazy odlotowe Emisja NO, NO (NO w przeliczeniu na NO) (z obliczen)","categories":["environment"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of NO, NO (NO calculated as NO) (calculated)","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5b3af482c33e0ee409523c","lab_id":"69ad52a3de79e566650fb0fd","country":"PL","accr_number":"AB 073","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia metali: As, Cd, Cr, Co, Cu, Mn, Pb, Sb, Tl, V","methodology_en":"Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Pb, Sb, Tl, V","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia metali: As, Cd, Cr, Co, Cu, Mn, Pb, Sb, Tl, V","reference":"PN-EN 14385:2005","norm_bases":["PN-EN 14385:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia metali: As, Cd, Cr, Co, Cu, Mn, Pb, Sb, Tl, V PN-EN 14385:2005 Gazy odlotowe Pobieranie probek do oznaczania stezenia metali: As, Cd, Cr, Co, Cu, Mn, Pb, Sb, Tl, V PN-EN 14385:2005","categories":["materials"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Pb, Sb, Tl, V PN-EN 14385:2005","search_zh":"废气 PN-EN 14385:2005","test_object_zh":"废气"},{"_id":"6a5b3af482c33e0ee409523d","lab_id":"69ad52a3de79e566650fb0fd","country":"PL","accr_number":"AB 073","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja metali: As, Cd, Cr, Co, Cu, Mn, Pb, Sb, Tl, V (z obliczeń)","methodology_en":"Emission of metals: As, Cd, Cr, Co, Cu, Mn, Pb, Sb, Tl, V (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja metali: As, Cd, Cr, Co, Cu, Mn, Pb, Sb, Tl, V (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja metali: As, Cd, Cr, Co, Cu, Mn, Pb, Sb, Tl, V (z obliczeń) Gazy odlotowe Emisja metali: As, Cd, Cr, Co, Cu, Mn, Pb, Sb, Tl, V (z obliczen)","categories":["materials","environment"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of metals: As, Cd, Cr, Co, Cu, Mn, Pb, Sb, Tl, V (calculated)","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5b3af482c33e0ee409523e","lab_id":"69ad52a3de79e566650fb0fd","country":"PL","accr_number":"AB 073","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia chlorowodoru","methodology_en":"Sampling for determination of hydrogen chloride concentration","parameters":[],"parameters_en":[],"technique":"Metoda aspiracyjna","techniques":["Metoda aspiracyjna"],"technique_en":"Aspiration method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia chlorowodoru\nMetoda aspiracyjna","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia chlorowodoru\nMetoda aspiracyjna PN-EN 1911:2011 Gazy odlotowe Pobieranie probek do oznaczania stezenia chlorowodoru\nMetoda aspiracyjna PN-EN 1911:2011","categories":["other"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of hydrogen chloride concentration Aspiration method PN-EN 1911:2011","search_zh":"废气 氯化氢浓度测定采样 抽气法 PN-EN 1911:2011","test_object_zh":"废气","technique_zh":"抽气法","methodology_zh":"氯化氢浓度测定采样"},{"_id":"6a5b3af482c33e0ee409523f","lab_id":"69ad52a3de79e566650fb0fd","country":"PL","accr_number":"AB 073","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja HCl (z obliczeń)","methodology_en":"HCl emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja HCl (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja HCl (z obliczeń) Gazy odlotowe Emisja HCl (z obliczen)","categories":["environment"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases HCl emission (calculated)","search_zh":"废气 HCl 排放（由计算得出）","test_object_zh":"废气","methodology_zh":"HCl 排放（由计算得出）"},{"_id":"6a5b3af482c33e0ee4095240","lab_id":"69ad52a3de79e566650fb0fd","country":"PL","accr_number":"AB 073","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenku węgla","methodology_en":"Carbon monoxide concentration","parameters":[{"name":"Stężenie tlenku węgla","range":"(5 – 1250) mg/m3"}],"parameters_en":[{"name":"Carbon monoxide concentration","range":"(5 – 1250) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"technique_en":"Non-dispersive infrared spectrometry (NDIR)","computed":[],"computed_en":[],"activity":"Stężenie tlenku węgla\nZakres: (5 – 1250) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN 15058: 2017-04","norm_bases":["PN-EN 15058: 2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenku węgla\nZakres: (5 – 1250) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15058: 2017-04 Gazy odlotowe Stezenie tlenku wegla\nZakres: (5 – 1250) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15058: 2017-04","categories":["other"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Carbon monoxide concentration Non-dispersive infrared spectrometry (NDIR) Carbon monoxide concentration PN-EN 15058: 2017-04","search_zh":"废气 一氧化碳浓度 非分散红外光谱法（NDIR） 一氧化碳浓度 PN-EN 15058: 2017-04","test_object_zh":"废气","methodology_zh":"一氧化碳浓度","parameters_zh":[{"name":"一氧化碳浓度","range":"(5 – 1250) mg/m3"}],"technique_zh":"非分散红外光谱法（NDIR）"},{"_id":"6a5b3af482c33e0ee4095241","lab_id":"69ad52a3de79e566650fb0fd","country":"PL","accr_number":"AB 073","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pary wodnej (H2O)","methodology_en":"Water vapour concentration (H2O)","parameters":[{"name":"Stężenie pary wodnej (H2O)","range":"(4,0 – 40) % obj. (29 – 250) g/m3"}],"parameters_en":[{"name":"Water vapour concentration (H2O)","range":"(4,0 – 40) % obj. (29 – 250) g/m3"}],"technique":"Metoda kondensacyjno-adsorpcyjna; Metoda temperaturowa","techniques":["Metoda kondensacyjno-adsorpcyjna","Metoda temperaturowa"],"technique_en":"Condensation-adsorption method; Temperature method","computed":[],"computed_en":[],"activity":"Stężenie pary wodnej (H2O)\nZakres: (4,0 – 40) % obj. (29 – 250) g/m3\nMetoda kondensacyjno-adsorpcyjna; Metoda temperaturowa","reference":"PN-EN 14790:2017-04","norm_bases":["PN-EN 14790:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pary wodnej (H2O)\nZakres: (4,0 – 40) % obj. (29 – 250) g/m3\nMetoda kondensacyjno-adsorpcyjna; Metoda temperaturowa PN-EN 14790:2017-04 Gazy odlotowe Stezenie pary wodnej (H2O)\nZakres: (4,0 – 40) % obj. (29 – 250) g/m3\nMetoda kondensacyjno-adsorpcyjna; Metoda temperaturowa PN-EN 14790:2017-04","categories":["other"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Water vapour concentration (H2O) Condensation-adsorption method; Temperature method Water vapour concentration (H2O) PN-EN 14790:2017-04","search_zh":"废气 水蒸气浓度（H2O） 冷凝-吸附法；温度法 水蒸气浓度（H2O） PN-EN 14790:2017-04","test_object_zh":"废气","methodology_zh":"水蒸气浓度（H2O）","parameters_zh":[{"name":"水蒸气浓度（H2O）","range":"(4,0 – 40) % obj. (29 – 250) g/m3"}],"technique_zh":"冷凝-吸附法；温度法"},{"_id":"6a5b3af482c33e0ee4095242","lab_id":"69ad52a3de79e566650fb0fd","country":"PL","accr_number":"AB 073","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania rtęci ogólnej","methodology_en":"Sampling for determination of total mercury","parameters":[],"parameters_en":[],"technique":"Metoda aspiracyjna","techniques":["Metoda aspiracyjna"],"technique_en":"Aspiration method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania rtęci ogólnej\nMetoda aspiracyjna","reference":"PN-EN 13211+AC:2006","norm_bases":["PN-EN 13211+AC:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania rtęci ogólnej\nMetoda aspiracyjna PN-EN 13211+AC:2006 Gazy odlotowe Pobieranie probek do oznaczania rteci ogolnej\nMetoda aspiracyjna PN-EN 13211+AC:2006","categories":["other"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of total mercury Aspiration method PN-EN 13211+AC:2006","search_zh":"废气 抽气法 PN-EN 13211+AC:2006","test_object_zh":"废气","technique_zh":"抽气法"},{"_id":"6a5b3af482c33e0ee4095243","lab_id":"69ad52a3de79e566650fb0fd","country":"PL","accr_number":"AB 073","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja rtęci ogólnej (z obliczeń)","methodology_en":"Total mercury emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja rtęci ogólnej (z obliczeń)","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja rtęci ogólnej (z obliczeń) ISO 15713:2006 Gazy odlotowe Emisja rteci ogolnej (z obliczen) ISO 15713:2006","categories":["environment"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Total mercury emission (calculated) ISO 15713:2006","search_zh":"废气 总汞排放量（计算值） ISO 15713:2006","test_object_zh":"废气","methodology_zh":"总汞排放量（计算值）"},{"_id":"6a5b3af482c33e0ee4095244","lab_id":"69ad52a3de79e566650fb0fd","country":"PL","accr_number":"AB 073","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia fluorowodoru","methodology_en":"Sampling for determination of hydrogen fluoride concentration","parameters":[],"parameters_en":[],"technique":"Metoda aspiracyjna","techniques":["Metoda aspiracyjna"],"technique_en":"Aspiration method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia fluorowodoru\nMetoda aspiracyjna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia fluorowodoru\nMetoda aspiracyjna Gazy odlotowe Pobieranie probek do oznaczania stezenia fluorowodoru\nMetoda aspiracyjna","categories":["other"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of hydrogen fluoride concentration Aspiration method","search_zh":"废气 氟化氢浓度测定采样 抽气法","test_object_zh":"废气","technique_zh":"抽气法","methodology_zh":"氟化氢浓度测定采样"},{"_id":"6a5b3af482c33e0ee4095245","lab_id":"69ad52a3de79e566650fb0fd","country":"PL","accr_number":"AB 073","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja HF (z obliczeń)","methodology_en":"HF emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja HF (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja HF (z obliczeń) Gazy odlotowe Emisja HF (z obliczen)","categories":["environment"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases HF emission (calculated)","search_zh":"废气 HF 排放量（计算值）","test_object_zh":"废气","methodology_zh":"HF 排放量（计算值）"},{"_id":"6a5b3af482c33e0ee4095246","lab_id":"69ad52a3de79e566650fb0fd","country":"PL","accr_number":"AB 073","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia kwasu siarkowego (VI)","methodology_en":"Sampling for determination of sulfuric (VI) acid concentration","parameters":[{"name":"Stężenie kwasu siarkowego (VI)","range":"(0,01 – 10) g/m3"}],"parameters_en":[{"name":"Sulfuric(VI) acid concentration","range":"(0,01 – 10) g/m3"}],"technique":"Metoda aspiracyjna z zastosowaniem roztworu pochłaniającego; Metoda aspiracyjna z zastosowaniem filtrów kwarcowych","techniques":["Metoda aspiracyjna z zastosowaniem roztworu pochłaniającego","Metoda aspiracyjna z zastosowaniem filtrów kwarcowych"],"technique_en":"Aspiration method using an absorbing solution; Aspiration method using quartz filters","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia kwasu siarkowego (VI)\nStężenie kwasu siarkowego (VI) (0,01 – 10) g/m3\nMetoda aspiracyjna z zastosowaniem roztworu pochłaniającego; Metoda aspiracyjna z zastosowaniem filtrów kwarcowych","reference":"PB-07/MO wyd. 4 z dn. 01.07.2022 r. | PB-08/MO wyd. 4 z dn. 01.07.2022 r. | PN-Z-04030-7:1994 | PN-Z-04030-7:1994","norm_bases":["PB-07/MO wyd. 4 z dn. 01.07.2022 r.","PB-08/MO wyd. 4 z dn. 01.07.2022 r.","PN-Z-04030-7:1994","PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia kwasu siarkowego (VI)\nStężenie kwasu siarkowego (VI) (0,01 – 10) g/m3\nMetoda aspiracyjna z zastosowaniem roztworu pochłaniającego; Metoda aspiracyjna z zastosowaniem filtrów kwarcowych PB-07/MO wyd. 4 z dn. 01.07.2022 r. | PB-08/MO wyd. 4 z dn. 01.07.2022 r. | PN-Z-04030-7:1994 | PN-Z-04030-7:1994 Gazy odlotowe Pobieranie probek do oznaczania stezenia kwasu siarkowego (VI)\nStezenie kwasu siarkowego (VI) (0,01 – 10) g/m3\nMetoda aspiracyjna z zastosowaniem roztworu pochlaniajacego; Metoda aspiracyjna z zastosowaniem filtrow kwarcowych PB-07/MO wyd. 4 z dn. 01.07.2022 r. | PB-08/MO wyd. 4 z dn. 01.07.2022 r. | PN-Z-04030-7:1994 | PN-Z-04030-7:1994","categories":["other"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of sulfuric (VI) acid concentration Aspiration method using an absorbing solution; Aspiration method using quartz filters Sulfuric(VI) acid concentration PB-07/MO wyd. 4 z dn. 01.07.2022 r. | PB-08/MO wyd. 4 z dn. 01.07.2022 r. | PN-Z-04030-7:1994 | PN-Z-04030-7:1994","search_zh":"废气 PB-07/MO wyd. 4 z dn. 01.07.2022 r. | PB-08/MO wyd. 4 z dn. 01.07.2022 r. | PN-Z-04030-7:1994 | PN-Z-04030-7:1994","test_object_zh":"废气"},{"_id":"6a5b3af482c33e0ee4095247","lab_id":"69ad52a3de79e566650fb0fd","country":"PL","accr_number":"AB 073","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja tlenku siarki (VI), kwasu siarkowego (VI)","methodology_en":"Emission of sulphur (VI) oxide, sulphuric (VI) acid","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja tlenku siarki (VI), kwasu siarkowego (VI)","reference":"PB-07/MO wyd. 4 z dn. 01.07.2022 r. | PB-08/MO wyd. 4 z dn. 01.07.2022 r. | PN-Z-04030-7:1994 | PN-Z-04030-7:1994","norm_bases":["PB-07/MO wyd. 4 z dn. 01.07.2022 r.","PB-08/MO wyd. 4 z dn. 01.07.2022 r.","PN-Z-04030-7:1994","PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja tlenku siarki (VI), kwasu siarkowego (VI) PB-07/MO wyd. 4 z dn. 01.07.2022 r. | PB-08/MO wyd. 4 z dn. 01.07.2022 r. | PN-Z-04030-7:1994 | PN-Z-04030-7:1994 Gazy odlotowe Emisja tlenku siarki (VI), kwasu siarkowego (VI) PB-07/MO wyd. 4 z dn. 01.07.2022 r. | PB-08/MO wyd. 4 z dn. 01.07.2022 r. | PN-Z-04030-7:1994 | PN-Z-04030-7:1994","categories":["environment"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of sulphur (VI) oxide, sulphuric (VI) acid PB-07/MO wyd. 4 z dn. 01.07.2022 r. | PB-08/MO wyd. 4 z dn. 01.07.2022 r. | PN-Z-04030-7:1994 | PN-Z-04030-7:1994","search_zh":"废气 PB-07/MO wyd. 4 z dn. 01.07.2022 r. | PB-08/MO wyd. 4 z dn. 01.07.2022 r. | PN-Z-04030-7:1994 | PN-Z-04030-7:1994","test_object_zh":"废气"},{"_id":"6a5b3af482c33e0ee4095248","lab_id":"69ad52a3de79e566650fb0fd","country":"PL","accr_number":"AB 073","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek pyłu do oznaczania stężeń metali w pyle","methodology_en":"Dust sampling for determination of metal concentrations in dust","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek pyłu do oznaczania stężeń metali w pyle","reference":"PB-07/MO wyd. 4 z dn. 01.07.2022 r. | PB-08/MO wyd. 4 z dn. 01.07.2022 r. | PN-Z-04030-7:1994 | PN-Z-04030-7:1994","norm_bases":["PB-07/MO wyd. 4 z dn. 01.07.2022 r.","PB-08/MO wyd. 4 z dn. 01.07.2022 r.","PN-Z-04030-7:1994","PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek pyłu do oznaczania stężeń metali w pyle PB-07/MO wyd. 4 z dn. 01.07.2022 r. | PB-08/MO wyd. 4 z dn. 01.07.2022 r. | PN-Z-04030-7:1994 | PN-Z-04030-7:1994 Gazy odlotowe Pobieranie probek pylu do oznaczania stezen metali w pyle PB-07/MO wyd. 4 z dn. 01.07.2022 r. | PB-08/MO wyd. 4 z dn. 01.07.2022 r. | PN-Z-04030-7:1994 | PN-Z-04030-7:1994","categories":["materials"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Dust sampling for determination of metal concentrations in dust PB-07/MO wyd. 4 z dn. 01.07.2022 r. | PB-08/MO wyd. 4 z dn. 01.07.2022 r. | PN-Z-04030-7:1994 | PN-Z-04030-7:1994","search_zh":"废气 PB-07/MO wyd. 4 z dn. 01.07.2022 r. | PB-08/MO wyd. 4 z dn. 01.07.2022 r. | PN-Z-04030-7:1994 | PN-Z-04030-7:1994","test_object_zh":"废气"},{"_id":"6a5b3af482c33e0ee4095249","lab_id":"69ad52a3de79e566650fb0fd","country":"PL","accr_number":"AB 073","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja metali w pyle","methodology_en":"Emission of metals in dust","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja metali w pyle","reference":"PB-07/MO wyd. 4 z dn. 01.07.2022 r. | PB-08/MO wyd. 4 z dn. 01.07.2022 r. | PN-Z-04030-7:1994 | PN-Z-04030-7:1994","norm_bases":["PB-07/MO wyd. 4 z dn. 01.07.2022 r.","PB-08/MO wyd. 4 z dn. 01.07.2022 r.","PN-Z-04030-7:1994","PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja metali w pyle PB-07/MO wyd. 4 z dn. 01.07.2022 r. | PB-08/MO wyd. 4 z dn. 01.07.2022 r. | PN-Z-04030-7:1994 | PN-Z-04030-7:1994 Gazy odlotowe Emisja metali w pyle PB-07/MO wyd. 4 z dn. 01.07.2022 r. | PB-08/MO wyd. 4 z dn. 01.07.2022 r. | PN-Z-04030-7:1994 | PN-Z-04030-7:1994","categories":["materials","environment"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of metals in dust PB-07/MO wyd. 4 z dn. 01.07.2022 r. | PB-08/MO wyd. 4 z dn. 01.07.2022 r. | PN-Z-04030-7:1994 | PN-Z-04030-7:1994","search_zh":"废气 PB-07/MO wyd. 4 z dn. 01.07.2022 r. | PB-08/MO wyd. 4 z dn. 01.07.2022 r. | PN-Z-04030-7:1994 | PN-Z-04030-7:1994","test_object_zh":"废气"},{"_id":"6a5b3af482c33e0ee409524a","lab_id":"69ad52a3de79e566650fb0fd","country":"PL","accr_number":"AB 073","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek pyłu do oznaczeń granulometrycznych","methodology_en":"Dust sampling for particle size determinations","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek pyłu do oznaczeń granulometrycznych","reference":"PB-07/MO wyd. 4 z dn. 01.07.2022 r. | PB-08/MO wyd. 4 z dn. 01.07.2022 r. | PN-Z-04030-7:1994 | PN-Z-04030-7:1994","norm_bases":["PB-07/MO wyd. 4 z dn. 01.07.2022 r.","PB-08/MO wyd. 4 z dn. 01.07.2022 r.","PN-Z-04030-7:1994","PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek pyłu do oznaczeń granulometrycznych PB-07/MO wyd. 4 z dn. 01.07.2022 r. | PB-08/MO wyd. 4 z dn. 01.07.2022 r. | PN-Z-04030-7:1994 | PN-Z-04030-7:1994 Gazy odlotowe Pobieranie probek pylu do oznaczen granulometrycznych PB-07/MO wyd. 4 z dn. 01.07.2022 r. | PB-08/MO wyd. 4 z dn. 01.07.2022 r. | PN-Z-04030-7:1994 | PN-Z-04030-7:1994","categories":["other"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Dust sampling for particle size determinations PB-07/MO wyd. 4 z dn. 01.07.2022 r. | PB-08/MO wyd. 4 z dn. 01.07.2022 r. | PN-Z-04030-7:1994 | PN-Z-04030-7:1994","search_zh":"废气 PB-07/MO wyd. 4 z dn. 01.07.2022 r. | PB-08/MO wyd. 4 z dn. 01.07.2022 r. | PN-Z-04030-7:1994 | PN-Z-04030-7:1994","test_object_zh":"废气"},{"_id":"6a5b3af482c33e0ee409524b","lab_id":"69ad52a3de79e566650fb0fd","country":"PL","accr_number":"AB 073","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja frakcji pyłu","methodology_en":"Emission of dust fractions","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja frakcji pyłu","reference":"PB-07/MO wyd. 4 z dn. 01.07.2022 r. | PB-08/MO wyd. 4 z dn. 01.07.2022 r. | PN-Z-04030-7:1994 | PN-Z-04030-7:1994","norm_bases":["PB-07/MO wyd. 4 z dn. 01.07.2022 r.","PB-08/MO wyd. 4 z dn. 01.07.2022 r.","PN-Z-04030-7:1994","PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja frakcji pyłu PB-07/MO wyd. 4 z dn. 01.07.2022 r. | PB-08/MO wyd. 4 z dn. 01.07.2022 r. | PN-Z-04030-7:1994 | PN-Z-04030-7:1994 Gazy odlotowe Emisja frakcji pylu PB-07/MO wyd. 4 z dn. 01.07.2022 r. | PB-08/MO wyd. 4 z dn. 01.07.2022 r. | PN-Z-04030-7:1994 | PN-Z-04030-7:1994","categories":["environment"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of dust fractions PB-07/MO wyd. 4 z dn. 01.07.2022 r. | PB-08/MO wyd. 4 z dn. 01.07.2022 r. | PN-Z-04030-7:1994 | PN-Z-04030-7:1994","search_zh":"废气 PB-07/MO wyd. 4 z dn. 01.07.2022 r. | PB-08/MO wyd. 4 z dn. 01.07.2022 r. | PN-Z-04030-7:1994 | PN-Z-04030-7:1994","test_object_zh":"废气"}],"has_pdf":true}