{"lab":{"_id":"69ad52a3de79e566650fb0e9","accr_number":"AB 049","country":"PL","accr_body":"PCA","address":"- WARSZAWSKI INSTYTUT TECHNOLOGICZNY, ul. Duchnicka 3, 01-796 Warszawa, LABORATORIUM MASZYN I KONSTRUKCJI","categories":["construction","materials"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":12,"name":"SIEĆ BADAWCZA ŁUKASIEWICZ","parse_status":"parsed","parse_version":3,"pdf_files":["AB_049.pdf"],"scope_summary":"","search_text":"sieć badawcza łukasiewicz - warszawski instytut technologiczny, ul. duchnicka 3, 01-796 warszawa, laboratorium maszyn i konstrukcji other construction materials metrology","status":"active","updated_at":"2026-03-08T14:50:05.908Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T08:13:49.969Z","parse_date":"2026-08-17T08:13:49.969Z","parse_source":"agent-claude-code","email_confidence":"high","email_mx":true,"email_source":"https://wit.lukasiewicz.gov.pl/kontakt/","fields_of_testing":[{"codes":"­ J/5; J/17","pl":"­ Badania mechaniczne wyrobów budowlanych i wyrobów innych","en":"Mechanical tests of building products and other products"},{"codes":"­ M/5; M/17","pl":"­ Badania inne ­ bezpieczeństwa użytkowania wyrobów budowlanych i wyrobów innych","en":"Other tests ­ safety tests for use of building products and other products"},{"codes":"­ N/5; N/17","pl":"­ Badania właściwości fizycznych wyrobów budowlanych i wyrobów innych","en":"Physical properties tests of building products and other products"}],"issue":{"no":"27","date":"12.08.2026"},"map_coord":[52.256758,20.968675],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM MASZYN I KONSTRUKCJI","address":"AB 049 ul. Racjonalizacji 6/8, 02-673 Warszawa","city":"Warszawa","postal":"02-673"}],"scope_format":"PCA::pracownie+siatka6","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/7def319a0f9b12054146c119440aad92/AB%20049.pdf","has_en":true,"category_counts":{"other":10,"construction":2,"materials":2},"category_scores":{"other":7.14,"construction":0.29,"materials":0.29},"has_zh":true},"methods":[{"_id":"6a82c2be884ede9a1b2c28c8","lab_id":"69ad52a3de79e566650fb0e9","country":"PL","accr_number":"AB 049","accr_body":"PCA","test_object":"Konstrukcje chroniące operatora maszyny","methodology":"Wytrzymałość konstrukcji ochronnej ROPS pod obciążeniem","parameters":[{"name":"Zakres","range":"do 2 MN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość konstrukcji ochronnej ROPS pod obciążeniem\nZakres do 2 MN","reference":"PN­EN ISO 3471:2009 | ISO 12117­2:2008","norm_bases":["PN­EN ISO 3471:2009","ISO 12117­2:2008"],"lab_section":"Laboratorium Maszyn i Konstrukcji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Konstrukcje chroniące operatora maszyny Wytrzymałość konstrukcji ochronnej ROPS pod obciążeniem\nZakres do 2 MN PN­EN ISO 3471:2009 | ISO 12117­2:2008 Konstrukcje chroniace operatora maszyny Wytrzymalosc konstrukcji ochronnej ROPS pod obciazeniem\nZakres do 2 MN PN­EN ISO 3471:2009 | ISO 12117­2:2008","categories":["other"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"do 2 MN"}],"search_en":"Structures protecting the machine operator Range PN­EN ISO 3471:2009 | ISO 12117­2:2008","test_object_en":"Structures protecting the machine operator","parameters_zh":[{"name":"范围","range":"do 2 MN"}],"search_zh":"范围 PN­EN ISO 3471:2009 | ISO 12117­2:2008"},{"_id":"6a82c2be884ede9a1b2c28c9","lab_id":"69ad52a3de79e566650fb0e9","country":"PL","accr_number":"AB 049","accr_body":"PCA","test_object":"Konstrukcje chroniące operatora maszyny","methodology":"Wytrzymałość konstrukcji ochronnej, FOPS o energii uderzenia do 60 kJ","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość konstrukcji ochronnej, FOPS o energii uderzenia do 60 kJ","reference":"PN­EN ISO 3449:2009","norm_bases":["PN­EN ISO 3449:2009"],"lab_section":"Laboratorium Maszyn i Konstrukcji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Konstrukcje chroniące operatora maszyny Wytrzymałość konstrukcji ochronnej, FOPS o energii uderzenia do 60 kJ PN­EN ISO 3449:2009 Konstrukcje chroniace operatora maszyny Wytrzymalosc konstrukcji ochronnej, FOPS o energii uderzenia do 60 kJ PN­EN ISO 3449:2009","categories":["other"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Structures protecting the machine operator PN­EN ISO 3449:2009","test_object_en":"Structures protecting the machine operator"},{"_id":"6a82c2be884ede9a1b2c28ca","lab_id":"69ad52a3de79e566650fb0e9","country":"PL","accr_number":"AB 049","accr_body":"PCA","test_object":"Konstrukcje (RSPS) chroniące operatora samojezdnych maszyn górniczych (SMG)","methodology":"Wytrzymałość na uderzenie obciążnikiem o masie do 6000 kg o energii uderzenia równej 60 kJ","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na uderzenie obciążnikiem o masie do 6000 kg o energii uderzenia równej 60 kJ","reference":"PN­92/G­59001 p. 3.3.5","norm_bases":["PN­92/G­59001 p. 3.3.5"],"lab_section":"Laboratorium Maszyn i Konstrukcji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Konstrukcje (RSPS) chroniące operatora samojezdnych maszyn górniczych (SMG) Wytrzymałość na uderzenie obciążnikiem o masie do 6000 kg o energii uderzenia równej 60 kJ PN­92/G­59001 p. 3.3.5 Konstrukcje (RSPS) chroniace operatora samojezdnych maszyn gorniczych (SMG) Wytrzymalosc na uderzenie obciaznikiem o masie do 6000 kg o energii uderzenia rownej 60 kJ PN­92/G­59001 p. 3.3.5","categories":["other"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Structures (RSPS) protecting the operator of self-propelled mining machines (SMG) PN­92/G­59001 p. 3.3.5","test_object_en":"Structures (RSPS) protecting the operator of self-propelled mining machines (SMG)"},{"_id":"6a82c2be884ede9a1b2c28cb","lab_id":"69ad52a3de79e566650fb0e9","country":"PL","accr_number":"AB 049","accr_body":"PCA","test_object":"Rury z betonu niezbrojonego, zbrojonego włóknem stalowym i żelbetowe","methodology":"Wytrzymałość pod obciążeniem statycznym","parameters":[{"name":"Zakres","range":"do 2 MN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość pod obciążeniem statycznym\nZakres do 2 MN","reference":"PN­EN 1916:2005 Załącznik C i D","norm_bases":["PN­EN 1916:2005 Załącznik C i D"],"lab_section":"Laboratorium Maszyn i Konstrukcji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Rury z betonu niezbrojonego, zbrojonego włóknem stalowym i żelbetowe Wytrzymałość pod obciążeniem statycznym\nZakres do 2 MN PN­EN 1916:2005 Załącznik C i D Rury z betonu niezbrojonego, zbrojonego wloknem stalowym i zelbetowe Wytrzymalosc pod obciazeniem statycznym\nZakres do 2 MN PN­EN 1916:2005 Zalacznik C i D","categories":["construction","materials"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Strength under static load","parameters_en":[{"name":"Range","range":"do 2 MN"}],"search_en":"Pipes of unreinforced concrete, steel fibre reinforced concrete and reinforced concrete Strength under static load Range PN­EN 1916:2005 Załącznik C i D","test_object_en":"Pipes of unreinforced concrete, steel fibre reinforced concrete and reinforced concrete","parameters_zh":[{"name":"范围","range":"do 2 MN"}],"search_zh":"静荷载下的强度 范围 PN­EN 1916:2005 Załącznik C i D","methodology_zh":"静荷载下的强度"},{"_id":"6a82c2be884ede9a1b2c28cc","lab_id":"69ad52a3de79e566650fb0e9","country":"PL","accr_number":"AB 049","accr_body":"PCA","test_object":"Studzienki włazowe i niewłazowe z betonu niezbrojonego, zbrojonego włóknem stalowym i żelbetowe","methodology":"Wytrzymałość pod obciążeniem statycznym","parameters":[{"name":"Zakres","range":"do 2 MN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość pod obciążeniem statycznym\nZakres do 2 MN","reference":"PN­EN 1917:2004 Załącznik A i B","norm_bases":["PN­EN 1917:2004 Załącznik A i B"],"lab_section":"Laboratorium Maszyn i Konstrukcji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Studzienki włazowe i niewłazowe z betonu niezbrojonego, zbrojonego włóknem stalowym i żelbetowe Wytrzymałość pod obciążeniem statycznym\nZakres do 2 MN PN­EN 1917:2004 Załącznik A i B Studzienki wlazowe i niewlazowe z betonu niezbrojonego, zbrojonego wloknem stalowym i zelbetowe Wytrzymalosc pod obciazeniem statycznym\nZakres do 2 MN PN­EN 1917:2004 Zalacznik A i B","categories":["construction","materials"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Strength under static load","parameters_en":[{"name":"Range","range":"do 2 MN"}],"search_en":"Manholes and inspection chambers of unreinforced concrete, steel fibre reinforced concrete and reinforced concrete Strength under static load Range PN­EN 1917:2004 Załącznik A i B","test_object_en":"Manholes and inspection chambers of unreinforced concrete, steel fibre reinforced concrete and reinforced concrete","parameters_zh":[{"name":"范围","range":"do 2 MN"}],"search_zh":"静荷载下的强度 范围 PN­EN 1917:2004 Załącznik A i B","methodology_zh":"静荷载下的强度"},{"_id":"6a82c2be884ede9a1b2c28cd","lab_id":"69ad52a3de79e566650fb0e9","country":"PL","accr_number":"AB 049","accr_body":"PCA","test_object":"Deskowania","methodology":"Wymiary geometryczne","parameters":[{"name":"Zakres","range":"do 30 m"},{"name":"Ciężar"},{"name":"Zakres","range":"do 100 kN"},{"name":"Wielkość odkształceń"},{"name":"Zakres","range":"do 1 m"},{"name":"Przy obciążeniu","range":"do 1000 kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wymiary geometryczne\nZakres:\nZakres do 30 m\nCiężar\nZakres do 100 kN\nWielkość odkształceń\nZakres do 1 m\nPrzy obciążeniu do 1000 kN","reference":"PB­040/3 z dnia 30.04.2011 r. PN­EN 1065:2001","norm_bases":["PB­040/3 z dnia 30.04.2011 r. PN­EN 1065:2001"],"lab_section":"Laboratorium Maszyn i Konstrukcji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Deskowania Wymiary geometryczne\nZakres:\nZakres do 30 m\nCiężar\nZakres do 100 kN\nWielkość odkształceń\nZakres do 1 m\nPrzy obciążeniu do 1000 kN PB­040/3 z dnia 30.04.2011 r. PN­EN 1065:2001 Deskowania Wymiary geometryczne\nZakres:\nZakres do 30 m\nCiezar\nZakres do 100 kN\nWielkosc odksztalcen\nZakres do 1 m\nPrzy obciazeniu do 1000 kN PB­040/3 z dnia 30.04.2011 r. PN­EN 1065:2001","categories":["other"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Geometric dimensions","parameters_en":[{"name":"Range","range":"do 30 m"},{"name":"Weight"},{"name":"Range","range":"do 100 kN"},{"name":"Magnitude of deformation"},{"name":"Range","range":"do 1 m"},{"name":"Under load","range":"do 1000 kN"}],"search_en":"Formwork Geometric dimensions Range Weight Range Magnitude of deformation Range Under load PB­040/3 z dnia 30.04.2011 r. PN­EN 1065:2001","test_object_en":"Formwork","parameters_zh":[{"name":"范围","range":"do 30 m"},{"name":"Ciężar"},{"name":"范围","range":"do 100 kN"},{"name":"Wielkość odkształceń"},{"name":"范围","range":"do 1 m"},{"name":"Przy obciążeniu","range":"do 1000 kN"}],"search_zh":"模板 几何尺寸 范围 范围 范围 PB­040/3 z dnia 30.04.2011 r. PN­EN 1065:2001","methodology_zh":"几何尺寸","test_object_zh":"模板"},{"_id":"6a82c2be884ede9a1b2c28ce","lab_id":"69ad52a3de79e566650fb0e9","country":"PL","accr_number":"AB 049","accr_body":"PCA","test_object":"Zawiesia","methodology":"Wymiary","parameters":[{"name":"Wymiary","range":"do 30 m"},{"name":"Nośność robocza","range":"do 1000 kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wymiary\nZakres:\nWymiary do 30 m\nNośność robocza do 1000 kN","reference":"PB­110/2 z dnia 30.08.2004 r.","norm_bases":["PB­110/2 z dnia 30.08.2004 r."],"lab_section":"Laboratorium Maszyn i Konstrukcji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zawiesia Wymiary\nZakres:\nWymiary do 30 m\nNośność robocza do 1000 kN PB­110/2 z dnia 30.08.2004 r. Zawiesia Wymiary\nZakres:\nWymiary do 30 m\nNosnosc robocza do 1000 kN PB­110/2 z dnia 30.08.2004 r.","categories":["other"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dimensions","parameters_en":[{"name":"Dimensions","range":"do 30 m"},{"name":"Working load limit","range":"do 1000 kN"}],"search_en":"Slings Dimensions Dimensions Working load limit PB­110/2 z dnia 30.08.2004 r.","test_object_en":"Slings","methodology_zh":"尺寸","parameters_zh":[{"name":"尺寸","range":"do 30 m"},{"name":"Nośność robocza","range":"do 1000 kN"}],"search_zh":"尺寸 尺寸 PB­110/2 z dnia 30.08.2004 r."},{"_id":"6a82c2be884ede9a1b2c28cf","lab_id":"69ad52a3de79e566650fb0e9","country":"PL","accr_number":"AB 049","accr_body":"PCA","test_object":"Zawiesia","methodology":"Bezpieczeństwo użytkowania, w tym wytrzymałość mechaniczna osłon","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Bezpieczeństwo użytkowania, w tym wytrzymałość mechaniczna osłon","reference":"PB­110/2 z dnia 30.08.2004 r.","norm_bases":["PB­110/2 z dnia 30.08.2004 r."],"lab_section":"Laboratorium Maszyn i Konstrukcji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zawiesia Bezpieczeństwo użytkowania, w tym wytrzymałość mechaniczna osłon PB­110/2 z dnia 30.08.2004 r. Zawiesia Bezpieczenstwo uzytkowania, w tym wytrzymalosc mechaniczna oslon PB­110/2 z dnia 30.08.2004 r.","categories":["other"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety in use, including mechanical strength of guards","search_en":"Slings Safety in use, including mechanical strength of guards PB­110/2 z dnia 30.08.2004 r.","test_object_en":"Slings"},{"_id":"6a82c2be884ede9a1b2c28d0","lab_id":"69ad52a3de79e566650fb0e9","country":"PL","accr_number":"AB 049","accr_body":"PCA","test_object":"Drabiny","methodology":"Wymiary geometryczne Wytrzymałość drabiny, stopni, szczebli i podestu","parameters":[{"name":"Ugięcia drabiny Odkształcenia przy wyłamywaniu dolnych końców podłużnic Odkształcenia przy skręcaniu"},{"name":"stopni/szczebli"},{"name":"Zakres","range":"do 20 m"}],"technique":null,"techniques":[],"computed":[],"activity":"Wymiary geometryczne Wytrzymałość drabiny, stopni, szczebli i podestu\nZakres:\nUgięcia drabiny Odkształcenia przy wyłamywaniu dolnych końców podłużnic Odkształcenia przy skręcaniu\nstopni/szczebli\nZakres do 20 m","reference":"PB­125/4 z dnia 31.07.2012 r.","norm_bases":["PB­125/4 z dnia 31.07.2012 r."],"lab_section":"Laboratorium Maszyn i Konstrukcji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Drabiny Wymiary geometryczne Wytrzymałość drabiny, stopni, szczebli i podestu\nZakres:\nUgięcia drabiny Odkształcenia przy wyłamywaniu dolnych końców podłużnic Odkształcenia przy skręcaniu\nstopni/szczebli\nZakres do 20 m PB­125/4 z dnia 31.07.2012 r. Drabiny Wymiary geometryczne Wytrzymalosc drabiny, stopni, szczebli i podestu\nZakres:\nUgiecia drabiny Odksztalcenia przy wylamywaniu dolnych koncow podluznic Odksztalcenia przy skrecaniu\nstopni/szczebli\nZakres do 20 m PB­125/4 z dnia 31.07.2012 r.","categories":["other"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Ugięcia drabiny Odkształcenia przy wyłamywaniu dolnych końców podłużnic Odkształcenia przy skręcaniu"},{"name":"stopni/szczebli"},{"name":"Range","range":"do 20 m"}],"search_en":"Ladders Range PB­125/4 z dnia 31.07.2012 r.","test_object_en":"Ladders","parameters_zh":[{"name":"Ugięcia drabiny Odkształcenia przy wyłamywaniu dolnych końców podłużnic Odkształcenia przy skręcaniu"},{"name":"stopni/szczebli"},{"name":"范围","range":"do 20 m"}],"search_zh":"梯子 范围 PB­125/4 z dnia 31.07.2012 r.","test_object_zh":"梯子"},{"_id":"6a82c2be884ede9a1b2c28d1","lab_id":"69ad52a3de79e566650fb0e9","country":"PL","accr_number":"AB 049","accr_body":"PCA","test_object":"Drabiny","methodology":"Bezpieczeństwo użytkowania, w tym: ­ stateczność poprzeczna drabiny magazynowej ­ skuteczność działania hamulca postojowego ­ wytrzymałość zabezpieczeń rozstawu ­ wytrzymałość urządzeń blokujących","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Bezpieczeństwo użytkowania, w tym: ­ stateczność poprzeczna drabiny magazynowej ­ skuteczność działania hamulca postojowego ­ wytrzymałość zabezpieczeń rozstawu ­ wytrzymałość urządzeń blokujących","reference":"PB­125/4 z dnia 31.07.2012 r.","norm_bases":["PB­125/4 z dnia 31.07.2012 r."],"lab_section":"Laboratorium Maszyn i Konstrukcji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Drabiny Bezpieczeństwo użytkowania, w tym: ­ stateczność poprzeczna drabiny magazynowej ­ skuteczność działania hamulca postojowego ­ wytrzymałość zabezpieczeń rozstawu ­ wytrzymałość urządzeń blokujących PB­125/4 z dnia 31.07.2012 r. Drabiny Bezpieczenstwo uzytkowania, w tym: ­ statecznosc poprzeczna drabiny magazynowej ­ skutecznosc dzialania hamulca postojowego ­ wytrzymalosc zabezpieczen rozstawu ­ wytrzymalosc urzadzen blokujacych PB­125/4 z dnia 31.07.2012 r.","categories":["other"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Ladders PB­125/4 z dnia 31.07.2012 r.","test_object_en":"Ladders","search_zh":"梯子 PB­125/4 z dnia 31.07.2012 r.","test_object_zh":"梯子"},{"_id":"6a82c2be884ede9a1b2c28d2","lab_id":"69ad52a3de79e566650fb0e9","country":"PL","accr_number":"AB 049","accr_body":"PCA","test_object":"Rusztowania systemowe stojące robocze","methodology":"Wymiary geometryczne Nośność, stateczność, sztywność rusztowań i elementów rusztowań oraz ich połączeń Grubość powłok ochronnych","parameters":[{"name":"Zakres","range":"(0 – 5) mm"},{"name":"Masa"},{"name":"Zakres","range":"(0.1 – 100) kg"}],"technique":null,"techniques":[],"computed":[],"activity":"Wymiary geometryczne Nośność, stateczność, sztywność rusztowań i elementów rusztowań oraz ich połączeń Grubość powłok ochronnych\nZakres:\nZakres (0 – 5) mm\nMasa\nZakres (0.1 – 100) kg","reference":"PB­030/2 z dnia 07.05.2007 r. PN­EN 74­1:2006 PN­EN 74­3:2007 PN­EN 12810­2:2010 PN­EN 12811­1:2007 PN­EN 12811­3:2003 PN­EN 12811­4:2014 PB­031/1 z dnia 15.03.2002 r.","norm_bases":["PB­030/2 z dnia 07.05.2007 r. PN­EN 74­1:2006 PN­EN 74­3:2007 PN­EN 12810­2:2010 PN­EN 12811­1:2007 PN­EN 12811­3:2003 PN­EN 12811­4:2014 PB­031/1 z dnia 15.03.2002 r."],"lab_section":"Laboratorium Maszyn i Konstrukcji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Rusztowania systemowe stojące robocze Wymiary geometryczne Nośność, stateczność, sztywność rusztowań i elementów rusztowań oraz ich połączeń Grubość powłok ochronnych\nZakres:\nZakres (0 – 5) mm\nMasa\nZakres (0.1 – 100) kg PB­030/2 z dnia 07.05.2007 r. PN­EN 74­1:2006 PN­EN 74­3:2007 PN­EN 12810­2:2010 PN­EN 12811­1:2007 PN­EN 12811­3:2003 PN­EN 12811­4:2014 PB­031/1 z dnia 15.03.2002 r. Rusztowania systemowe stojace robocze Wymiary geometryczne Nosnosc, statecznosc, sztywnosc rusztowan i elementow rusztowan oraz ich polaczen Grubosc powlok ochronnych\nZakres:\nZakres (0 – 5) mm\nMasa\nZakres (0.1 – 100) kg PB­030/2 z dnia 07.05.2007 r. PN­EN 74­1:2006 PN­EN 74­3:2007 PN­EN 12810­2:2010 PN­EN 12811­1:2007 PN­EN 12811­3:2003 PN­EN 12811­4:2014 PB­031/1 z dnia 15.03.2002 r.","categories":["other"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0 – 5) mm"},{"name":"Mass"},{"name":"Range","range":"(0.1 – 100) kg"}],"search_en":"Prefabricated working scaffolds Range Mass Range PB­030/2 z dnia 07.05.2007 r. PN­EN 74­1:2006 PN­EN 74­3:2007 PN­EN 12810­2:2010 PN­EN 12811­1:2007 PN­EN 12811­3:2003 PN­EN 12811­4:2014 PB­031/1 z dnia 15.03.2002 r.","test_object_en":"Prefabricated working scaffolds","parameters_zh":[{"name":"范围","range":"(0 – 5) mm"},{"name":"质量"},{"name":"范围","range":"(0.1 – 100) kg"}],"search_zh":"系统式落地作业脚手架 范围 质量 范围 PB­030/2 z dnia 07.05.2007 r. PN­EN 74­1:2006 PN­EN 74­3:2007 PN­EN 12810­2:2010 PN­EN 12811­1:2007 PN­EN 12811­3:2003 PN­EN 12811­4:2014 PB­031/1 z dnia 15.03.2002 r.","test_object_zh":"系统式落地作业脚手架"},{"_id":"6a82c2be884ede9a1b2c28d3","lab_id":"69ad52a3de79e566650fb0e9","country":"PL","accr_number":"AB 049","accr_body":"PCA","test_object":"Rusztowania systemowe stojące robocze","methodology":"Bezpieczeństwo użytkowania, w tym: ­ stan połączeń spawanych ­ skuteczność zabezpieczeń połączeń rozłącznych ­ właściwości ergonomiczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Bezpieczeństwo użytkowania, w tym: ­ stan połączeń spawanych ­ skuteczność zabezpieczeń połączeń rozłącznych ­ właściwości ergonomiczne","reference":"PB­030/2 z dnia 07.05.2007 r. PN­EN 74­1:2006 PN­EN 74­3:2007 PN­EN 12810­2:2010 PN­EN 12811­1:2007 PN­EN 12811­3:2003 PN­EN 12811­4:2014 PB­031/1 z dnia 15.03.2002 r.","norm_bases":["PB­030/2 z dnia 07.05.2007 r. PN­EN 74­1:2006 PN­EN 74­3:2007 PN­EN 12810­2:2010 PN­EN 12811­1:2007 PN­EN 12811­3:2003 PN­EN 12811­4:2014 PB­031/1 z dnia 15.03.2002 r."],"lab_section":"Laboratorium Maszyn i Konstrukcji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Rusztowania systemowe stojące robocze Bezpieczeństwo użytkowania, w tym: ­ stan połączeń spawanych ­ skuteczność zabezpieczeń połączeń rozłącznych ­ właściwości ergonomiczne PB­030/2 z dnia 07.05.2007 r. PN­EN 74­1:2006 PN­EN 74­3:2007 PN­EN 12810­2:2010 PN­EN 12811­1:2007 PN­EN 12811­3:2003 PN­EN 12811­4:2014 PB­031/1 z dnia 15.03.2002 r. Rusztowania systemowe stojace robocze Bezpieczenstwo uzytkowania, w tym: ­ stan polaczen spawanych ­ skutecznosc zabezpieczen polaczen rozlacznych ­ wlasciwosci ergonomiczne PB­030/2 z dnia 07.05.2007 r. PN­EN 74­1:2006 PN­EN 74­3:2007 PN­EN 12810­2:2010 PN­EN 12811­1:2007 PN­EN 12811­3:2003 PN­EN 12811­4:2014 PB­031/1 z dnia 15.03.2002 r.","categories":["other"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Prefabricated working scaffolds PB­030/2 z dnia 07.05.2007 r. PN­EN 74­1:2006 PN­EN 74­3:2007 PN­EN 12810­2:2010 PN­EN 12811­1:2007 PN­EN 12811­3:2003 PN­EN 12811­4:2014 PB­031/1 z dnia 15.03.2002 r.","test_object_en":"Prefabricated working scaffolds","search_zh":"系统式落地作业脚手架 PB­030/2 z dnia 07.05.2007 r. PN­EN 74­1:2006 PN­EN 74­3:2007 PN­EN 12810­2:2010 PN­EN 12811­1:2007 PN­EN 12811­3:2003 PN­EN 12811­4:2014 PB­031/1 z dnia 15.03.2002 r.","test_object_zh":"系统式落地作业脚手架"}],"has_pdf":true}