{"lab":{"_id":"69ad52a3de79e566650fb0d3","accr_number":"AB 025","country":"PL","accr_body":"PCA","address":"LABORATORIUM BADAŃ MATERIAŁOWYCH, ul. Andrzeja Sołtana 7, 05-400 Otwock","categories":["materials"],"city":"Otwock","imported_at":"2026-03-08T10:42:43.265Z","methods_count":12,"name":"NARODOWE CENTRUM BADAŃ JĄDROWYCH","parse_status":"parsed","parse_version":3,"pdf_files":["AB_025.pdf"],"scope_summary":"","search_text":"narodowe centrum badań jądrowych laboratorium badań materiałowych, ul. andrzeja sołtana 7, 05-400 otwock other materials","status":"active","updated_at":"2026-03-08T14:50:03.879Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T07:30:17.075Z","parse_date":"2026-08-13T07:30:17.075Z","parse_source":"agent-claude-code","email_confidence":"high","email_mx":true,"email_source":"https://bip.ncbj.gov.pl/artykul/38/25/dane-teleadresowe","fields_of_testing":[{"codes":"J/8","pl":"Badania mechaniczne, badania metalograficzne wyrobów i materiałów konstrukcyjnych","en":"Mechanical tests, metallographic tests of construction products and materials"}],"issue":{"no":"27","date":"10.06.2026"},"map_coord":[52.125655,21.338909],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM BADAŃ MATERIAŁOWYCH","address":"ul. Andrzeja Sołtana 7","city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/13197f69db773bc98e3e490f63583fbf/AB%20025.pdf","has_en":true,"category_counts":{"materials":10,"other":2},"category_scores":{"materials":8.33,"other":0.33},"has_zh":true},"methods":[{"_id":"6a7d7289ec6a53014a487575","lab_id":"69ad52a3de79e566650fb0d3","country":"PL","accr_number":"AB 025","accr_body":"PCA","test_object":"Złącza spawane nienapromienione i napromienione","methodology":"Makro- i mikrostruktura złączy spawanych","parameters":[],"technique":"Metoda mikroskopii optycznej","techniques":["Metoda mikroskopii optycznej"],"computed":[],"activity":"Makro- i mikrostruktura złączy spawanych\nMetoda mikroskopii optycznej","reference":"PN-EN ISO 17639:2022-07 | PN-EN ISO 5817:2023-08","norm_bases":["PN-EN ISO 17639:2022-07","PN-EN ISO 5817:2023-08"],"lab_section":"Laboratorium Badań Materiałowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Złącza spawane nienapromienione i napromienione Makro- i mikrostruktura złączy spawanych\nMetoda mikroskopii optycznej PN-EN ISO 17639:2022-07 | PN-EN ISO 5817:2023-08 Zlacza spawane nienapromienione i napromienione Makro- i mikrostruktura zlaczy spawanych\nMetoda mikroskopii optycznej PN-EN ISO 17639:2022-07 | PN-EN ISO 5817:2023-08","categories":["other"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Materials Testing Laboratory","methodology_en":"Macro- and microstructure of welded joints","search_en":"Non-irradiated and irradiated welded joints Macro- and microstructure of welded joints Optical microscopy method Materials Testing Laboratory PN-EN ISO 17639:2022-07 | PN-EN ISO 5817:2023-08","technique_en":"Optical microscopy method","test_object_en":"Non-irradiated and irradiated welded joints","search_zh":"光学显微镜法 材料检验实验室 PN-EN ISO 17639:2022-07 | PN-EN ISO 5817:2023-08","technique_zh":"光学显微镜法","lab_section_zh":"材料检验实验室"},{"_id":"6a7d7289ec6a53014a487576","lab_id":"69ad52a3de79e566650fb0d3","country":"PL","accr_number":"AB 025","accr_body":"PCA","test_object":"Metale i ich stopy nienapromienione","methodology":"Własności mechaniczne:","parameters":[{"name":"wytrzymałość na rozciąganie – Rm"},{"name":"umowna granica plastyczności - Rp0,2"},{"name":"wyraźna granica plastyczności - Re"},{"name":"wydłużenie względne próbki A"},{"name":"przewężenie względne próbki Z"},{"name":"siła F","range":"do 100 kN"},{"name":"Temperatura badania: pokojowa Próba rozciągania"}],"technique":null,"techniques":[],"computed":[],"activity":"Własności mechaniczne:\nZakres:\nwytrzymałość na rozciąganie – Rm\numowna granica plastyczności - Rp0,2\nwyraźna granica plastyczności - Re\nwydłużenie względne próbki A\nprzewężenie względne próbki Z\nsiła F do 100 kN\nTemperatura badania: pokojowa Próba rozciągania","reference":"PN-EN ISO 6892-1:2020-05 metoda B","norm_bases":["PN-EN ISO 6892-1:2020-05 metoda B"],"lab_section":"Laboratorium Badań Materiałowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Metale i ich stopy nienapromienione Własności mechaniczne:\nZakres:\nwytrzymałość na rozciąganie – Rm\numowna granica plastyczności - Rp0,2\nwyraźna granica plastyczności - Re\nwydłużenie względne próbki A\nprzewężenie względne próbki Z\nsiła F do 100 kN\nTemperatura badania: pokojowa Próba rozciągania PN-EN ISO 6892-1:2020-05 metoda B Metale i ich stopy nienapromienione Wlasnosci mechaniczne:\nZakres:\nwytrzymalosc na rozciaganie – Rm\numowna granica plastycznosci - Rp0,2\nwyrazna granica plastycznosci - Re\nwydluzenie wzgledne probki A\nprzewezenie wzgledne probki Z\nsila F do 100 kN\nTemperatura badania: pokojowa Proba rozciagania PN-EN ISO 6892-1:2020-05 metoda B","categories":["materials"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Materials Testing Laboratory","methodology_en":"Mechanical properties:","parameters_en":[{"name":"tensile strength – Rm"},{"name":"proof strength - Rp0,2"},{"name":"distinct yield strength - Re"},{"name":"percentage elongation of the specimen A"},{"name":"percentage reduction of area of the specimen Z"},{"name":"force F","range":"do 100 kN"},{"name":"Test temperature: room Tensile test"}],"search_en":"Metals and their alloys, unirradiated Mechanical properties: Materials Testing Laboratory tensile strength – Rm proof strength - Rp0,2 distinct yield strength - Re percentage elongation of the specimen A percentage reduction of area of the specimen Z force F Test temperature: room Tensile test PN-EN ISO 6892-1:2020-05 metoda B","test_object_en":"Metals and their alloys, unirradiated","methodology_zh":"力学性能：","search_zh":"未辐照的金属及其合金 力学性能： 材料检验实验室 抗拉强度 － Rm 明显屈服强度 － Re 试样相对伸长率 A 试样相对断面收缩率 Z 力 F PN-EN ISO 6892-1:2020-05 metoda B","parameters_zh":[{"name":"抗拉强度 － Rm"},{"name":"umowna granica plastyczności - Rp0,2"},{"name":"明显屈服强度 － Re"},{"name":"试样相对伸长率 A"},{"name":"试样相对断面收缩率 Z"},{"name":"力 F","range":"do 100 kN"},{"name":"Temperatura badania: pokojowa Próba rozciągania"}],"lab_section_zh":"材料检验实验室","test_object_zh":"未辐照的金属及其合金"},{"_id":"6a7d7289ec6a53014a487577","lab_id":"69ad52a3de79e566650fb0d3","country":"PL","accr_number":"AB 025","accr_body":"PCA","test_object":"Metale i ich stopy nienapromienione","methodology":"Własności mechaniczne:","parameters":[{"name":"wytrzymałość na rozciąganie - Rm"},{"name":"umowna granica plastyczności -Rp0,2"},{"name":"wyraźna granica plastyczności - Re"},{"name":"wydłużenie względne próbki A"},{"name":"przewężenie względne próbki Z"},{"name":"siła F","range":"do 100 kN"},{"name":"Temperatura podwyższona","range":"do 1000 °C"},{"name":"Próba rozciągania"}],"technique":null,"techniques":[],"computed":[],"activity":"Własności mechaniczne:\nZakres:\nwytrzymałość na rozciąganie - Rm\numowna granica plastyczności -Rp0,2\nwyraźna granica plastyczności - Re\nwydłużenie względne próbki A\nprzewężenie względne próbki Z\nsiła F do 100 kN\nTemperatura podwyższona do 1000 °C\nPróba rozciągania","reference":"PN-EN ISO 6892-2:2018-08 metoda B","norm_bases":["PN-EN ISO 6892-2:2018-08 metoda B"],"lab_section":"Laboratorium Badań Materiałowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Metale i ich stopy nienapromienione Własności mechaniczne:\nZakres:\nwytrzymałość na rozciąganie - Rm\numowna granica plastyczności -Rp0,2\nwyraźna granica plastyczności - Re\nwydłużenie względne próbki A\nprzewężenie względne próbki Z\nsiła F do 100 kN\nTemperatura podwyższona do 1000 °C\nPróba rozciągania PN-EN ISO 6892-2:2018-08 metoda B Metale i ich stopy nienapromienione Wlasnosci mechaniczne:\nZakres:\nwytrzymalosc na rozciaganie - Rm\numowna granica plastycznosci -Rp0,2\nwyrazna granica plastycznosci - Re\nwydluzenie wzgledne probki A\nprzewezenie wzgledne probki Z\nsila F do 100 kN\nTemperatura podwyzszona do 1000 °C\nProba rozciagania PN-EN ISO 6892-2:2018-08 metoda B","categories":["materials"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Materials Testing Laboratory","methodology_en":"Mechanical properties:","parameters_en":[{"name":"tensile strength - Rm"},{"name":"proof strength -Rp0,2"},{"name":"distinct yield strength - Re"},{"name":"percentage elongation of the specimen A"},{"name":"percentage reduction of area of the specimen Z"},{"name":"force F","range":"do 100 kN"},{"name":"Elevated temperature","range":"do 1000 °C"},{"name":"Tensile test"}],"search_en":"Metals and their alloys, unirradiated Mechanical properties: Materials Testing Laboratory tensile strength - Rm proof strength -Rp0,2 distinct yield strength - Re percentage elongation of the specimen A percentage reduction of area of the specimen Z force F Elevated temperature Tensile test PN-EN ISO 6892-2:2018-08 metoda B","test_object_en":"Metals and their alloys, unirradiated","methodology_zh":"力学性能：","search_zh":"未辐照的金属及其合金 力学性能： 材料检验实验室 抗拉强度 － Rm 明显屈服强度 － Re 试样相对伸长率 A 试样相对断面收缩率 Z 力 F 拉伸试验 PN-EN ISO 6892-2:2018-08 metoda B","parameters_zh":[{"name":"抗拉强度 － Rm"},{"name":"umowna granica plastyczności -Rp0,2"},{"name":"明显屈服强度 － Re"},{"name":"试样相对伸长率 A"},{"name":"试样相对断面收缩率 Z"},{"name":"力 F","range":"do 100 kN"},{"name":"Temperatura podwyższona","range":"do 1000 °C"},{"name":"拉伸试验"}],"lab_section_zh":"材料检验实验室","test_object_zh":"未辐照的金属及其合金"},{"_id":"6a7d7289ec6a53014a487578","lab_id":"69ad52a3de79e566650fb0d3","country":"PL","accr_number":"AB 025","accr_body":"PCA","test_object":"Metale i ich stopy nienapromienione","methodology":"Własności mechaniczne:","parameters":[{"name":"wytrzymałość na rozciąganie - Rm"},{"name":"umowna granica plastyczności -Rp0,2"},{"name":"wyraźna granica plastyczności - Re"},{"name":"wydłużenie względne próbki A"},{"name":"przewężenie względne próbki Z"},{"name":"siła F","range":"do 100 kN"},{"name":"temperatura obniżona do –40 °C Próba rozciągania"}],"technique":null,"techniques":[],"computed":[],"activity":"Własności mechaniczne:\nZakres:\nwytrzymałość na rozciąganie - Rm\numowna granica plastyczności -Rp0,2\nwyraźna granica plastyczności - Re\nwydłużenie względne próbki A\nprzewężenie względne próbki Z\nsiła F do 100 kN\ntemperatura obniżona do –40 °C Próba rozciągania","reference":"ISO 6892-3:2015 metoda B","norm_bases":["ISO 6892-3:2015 metoda B"],"lab_section":"Laboratorium Badań Materiałowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Metale i ich stopy nienapromienione Własności mechaniczne:\nZakres:\nwytrzymałość na rozciąganie - Rm\numowna granica plastyczności -Rp0,2\nwyraźna granica plastyczności - Re\nwydłużenie względne próbki A\nprzewężenie względne próbki Z\nsiła F do 100 kN\ntemperatura obniżona do –40 °C Próba rozciągania ISO 6892-3:2015 metoda B Metale i ich stopy nienapromienione Wlasnosci mechaniczne:\nZakres:\nwytrzymalosc na rozciaganie - Rm\numowna granica plastycznosci -Rp0,2\nwyrazna granica plastycznosci - Re\nwydluzenie wzgledne probki A\nprzewezenie wzgledne probki Z\nsila F do 100 kN\ntemperatura obnizona do –40 °C Proba rozciagania ISO 6892-3:2015 metoda B","categories":["materials"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Materials Testing Laboratory","methodology_en":"Mechanical properties:","parameters_en":[{"name":"tensile strength - Rm"},{"name":"proof strength -Rp0,2"},{"name":"distinct yield strength - Re"},{"name":"percentage elongation of the specimen A"},{"name":"percentage reduction of area of the specimen Z"},{"name":"force F","range":"do 100 kN"},{"name":"reduced temperature down to –40 °C Tensile test"}],"search_en":"Metals and their alloys, unirradiated Mechanical properties: Materials Testing Laboratory tensile strength - Rm proof strength -Rp0,2 distinct yield strength - Re percentage elongation of the specimen A percentage reduction of area of the specimen Z force F reduced temperature down to –40 °C Tensile test ISO 6892-3:2015 metoda B","test_object_en":"Metals and their alloys, unirradiated","methodology_zh":"力学性能：","search_zh":"未辐照的金属及其合金 力学性能： 材料检验实验室 抗拉强度 － Rm 明显屈服强度 － Re 试样相对伸长率 A 试样相对断面收缩率 Z 力 F ISO 6892-3:2015 metoda B","parameters_zh":[{"name":"抗拉强度 － Rm"},{"name":"umowna granica plastyczności -Rp0,2"},{"name":"明显屈服强度 － Re"},{"name":"试样相对伸长率 A"},{"name":"试样相对断面收缩率 Z"},{"name":"力 F","range":"do 100 kN"},{"name":"temperatura obniżona do –40 °C Próba rozciągania"}],"lab_section_zh":"材料检验实验室","test_object_zh":"未辐照的金属及其合金"},{"_id":"6a7d7289ec6a53014a487579","lab_id":"69ad52a3de79e566650fb0d3","country":"PL","accr_number":"AB 025","accr_body":"PCA","test_object":"Metale i ich stopy napromienione","methodology":"Własności mechaniczne:","parameters":[{"name":"wytrzymałość na rozciąganie - Rm"},{"name":"umowna granica plastyczności - Rp0,2"},{"name":"wyraźna granica plastyczności - Re"},{"name":"wydłużenie względne próbki A"},{"name":"przewężenie względne próbki Z"},{"name":"siła F","range":"do 100 kN"},{"name":"temperatura badania: pokojowa Próba rozciągania"}],"technique":null,"techniques":[],"computed":[],"activity":"Własności mechaniczne:\nZakres:\nwytrzymałość na rozciąganie - Rm\numowna granica plastyczności - Rp0,2\nwyraźna granica plastyczności - Re\nwydłużenie względne próbki A\nprzewężenie względne próbki Z\nsiła F do 100 kN\ntemperatura badania: pokojowa Próba rozciągania","reference":"PN-EN ISO 6892-1:2020-05 metoda B","norm_bases":["PN-EN ISO 6892-1:2020-05 metoda B"],"lab_section":"Laboratorium Badań Materiałowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Metale i ich stopy napromienione Własności mechaniczne:\nZakres:\nwytrzymałość na rozciąganie - Rm\numowna granica plastyczności - Rp0,2\nwyraźna granica plastyczności - Re\nwydłużenie względne próbki A\nprzewężenie względne próbki Z\nsiła F do 100 kN\ntemperatura badania: pokojowa Próba rozciągania PN-EN ISO 6892-1:2020-05 metoda B Metale i ich stopy napromienione Wlasnosci mechaniczne:\nZakres:\nwytrzymalosc na rozciaganie - Rm\numowna granica plastycznosci - Rp0,2\nwyrazna granica plastycznosci - Re\nwydluzenie wzgledne probki A\nprzewezenie wzgledne probki Z\nsila F do 100 kN\ntemperatura badania: pokojowa Proba rozciagania PN-EN ISO 6892-1:2020-05 metoda B","categories":["materials"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Materials Testing Laboratory","methodology_en":"Mechanical properties:","parameters_en":[{"name":"tensile strength - Rm"},{"name":"proof strength - Rp0,2"},{"name":"distinct yield strength - Re"},{"name":"percentage elongation of the specimen A"},{"name":"percentage reduction of area of the specimen Z"},{"name":"force F","range":"do 100 kN"},{"name":"test temperature: room Tensile test"}],"search_en":"Irradiated metals and their alloys Mechanical properties: Materials Testing Laboratory tensile strength - Rm proof strength - Rp0,2 distinct yield strength - Re percentage elongation of the specimen A percentage reduction of area of the specimen Z force F test temperature: room Tensile test PN-EN ISO 6892-1:2020-05 metoda B","test_object_en":"Irradiated metals and their alloys","methodology_zh":"力学性能：","search_zh":"力学性能： 材料检验实验室 抗拉强度 － Rm 明显屈服强度 － Re 试样相对伸长率 A 试样相对断面收缩率 Z 力 F PN-EN ISO 6892-1:2020-05 metoda B","parameters_zh":[{"name":"抗拉强度 － Rm"},{"name":"umowna granica plastyczności - Rp0,2"},{"name":"明显屈服强度 － Re"},{"name":"试样相对伸长率 A"},{"name":"试样相对断面收缩率 Z"},{"name":"力 F","range":"do 100 kN"},{"name":"temperatura badania: pokojowa Próba rozciągania"}],"lab_section_zh":"材料检验实验室"},{"_id":"6a7d7289ec6a53014a48757a","lab_id":"69ad52a3de79e566650fb0d3","country":"PL","accr_number":"AB 025","accr_body":"PCA","test_object":"Złącza spawane nienapromienione i napromienione","methodology":"Własności mechaniczne:","parameters":[{"name":"największa siła Fm"},{"name":"wytrzymałość na rozciąganie - Rm"}],"technique":null,"techniques":[],"computed":[],"activity":"Własności mechaniczne:\nZakres:\nnajwiększa siła Fm\nwytrzymałość na rozciąganie - Rm","reference":"PN-EN ISO 6892-1:2020-05 metoda B | PN-EN ISO 5178:2019-04 | PN-EN ISO 4136:2022-12","norm_bases":["PN-EN ISO 6892-1:2020-05 metoda B","PN-EN ISO 5178:2019-04","PN-EN ISO 4136:2022-12"],"lab_section":"Laboratorium Badań Materiałowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Złącza spawane nienapromienione i napromienione Własności mechaniczne:\nZakres:\nnajwiększa siła Fm\nwytrzymałość na rozciąganie - Rm PN-EN ISO 6892-1:2020-05 metoda B | PN-EN ISO 5178:2019-04 | PN-EN ISO 4136:2022-12 Zlacza spawane nienapromienione i napromienione Wlasnosci mechaniczne:\nZakres:\nnajwieksza sila Fm\nwytrzymalosc na rozciaganie - Rm PN-EN ISO 6892-1:2020-05 metoda B | PN-EN ISO 5178:2019-04 | PN-EN ISO 4136:2022-12","categories":["other"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Materials Testing Laboratory","methodology_en":"Mechanical properties:","parameters_en":[{"name":"maximum force Fm"},{"name":"tensile strength - Rm"}],"search_en":"Non-irradiated and irradiated welded joints Mechanical properties: Materials Testing Laboratory maximum force Fm tensile strength - Rm PN-EN ISO 6892-1:2020-05 metoda B | PN-EN ISO 5178:2019-04 | PN-EN ISO 4136:2022-12","test_object_en":"Non-irradiated and irradiated welded joints","methodology_zh":"力学性能：","search_zh":"力学性能： 材料检验实验室 最大力 Fm 抗拉强度 － Rm PN-EN ISO 6892-1:2020-05 metoda B | PN-EN ISO 5178:2019-04 | PN-EN ISO 4136:2022-12","lab_section_zh":"材料检验实验室","parameters_zh":[{"name":"最大力 Fm"},{"name":"抗拉强度 － Rm"}]},{"_id":"6a7d7289ec6a53014a48757b","lab_id":"69ad52a3de79e566650fb0d3","country":"PL","accr_number":"AB 025","accr_body":"PCA","test_object":"Metale i ich stopy oraz złącza spawane nienapromienione i napromienione","methodology":"Twardość HRC, HRA, HRBW, Skala: C, A, B","parameters":[],"technique":"Metoda Rockwella","techniques":["Metoda Rockwella"],"computed":[],"activity":"Twardość HRC, HRA, HRBW, Skala: C, A, B\nMetoda Rockwella","reference":"PN-EN ISO 6508-1:2024-06","norm_bases":["PN-EN ISO 6508-1:2024-06"],"lab_section":"Laboratorium Badań Materiałowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Metale i ich stopy oraz złącza spawane nienapromienione i napromienione Twardość HRC, HRA, HRBW, Skala: C, A, B\nMetoda Rockwella PN-EN ISO 6508-1:2024-06 Metale i ich stopy oraz zlacza spawane nienapromienione i napromienione Twardosc HRC, HRA, HRBW, Skala: C, A, B\nMetoda Rockwella PN-EN ISO 6508-1:2024-06","categories":["materials"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Materials Testing Laboratory","methodology_en":"HRC, HRA, HRBW hardness, Scale: C, A, B","search_en":"Metals and their alloys and welded joints, unirradiated and irradiated HRC, HRA, HRBW hardness, Scale: C, A, B Rockwell method Materials Testing Laboratory PN-EN ISO 6508-1:2024-06","technique_en":"Rockwell method","test_object_en":"Metals and their alloys and welded joints, unirradiated and irradiated","search_zh":"未辐照与已辐照的金属及其合金以及焊接接头 洛氏法 材料检验实验室 PN-EN ISO 6508-1:2024-06","technique_zh":"洛氏法","lab_section_zh":"材料检验实验室","test_object_zh":"未辐照与已辐照的金属及其合金以及焊接接头"},{"_id":"6a7d7289ec6a53014a48757c","lab_id":"69ad52a3de79e566650fb0d3","country":"PL","accr_number":"AB 025","accr_body":"PCA","test_object":"Metale i ich stopy oraz złącza spawane nienapromienione i napromienione","methodology":"Twardość HV","parameters":[{"name":"Zakres","range":"HV 5, HV 10, HV 30"}],"technique":"Metoda Vickersa","techniques":["Metoda Vickersa"],"computed":[],"activity":"Twardość HV\nZakres HV 5, HV 10, HV 30\nMetoda Vickersa","reference":"PN-EN ISO 6507-1:2024-04","norm_bases":["PN-EN ISO 6507-1:2024-04"],"lab_section":"Laboratorium Badań Materiałowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Metale i ich stopy oraz złącza spawane nienapromienione i napromienione Twardość HV\nZakres HV 5, HV 10, HV 30\nMetoda Vickersa PN-EN ISO 6507-1:2024-04 Metale i ich stopy oraz zlacza spawane nienapromienione i napromienione Twardosc HV\nZakres HV 5, HV 10, HV 30\nMetoda Vickersa PN-EN ISO 6507-1:2024-04","categories":["materials"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Materials Testing Laboratory","methodology_en":"HV hardness","parameters_en":[{"name":"Range","range":"HV 5, HV 10, HV 30"}],"search_en":"Metals and their alloys and welded joints, unirradiated and irradiated HV hardness Vickers method Materials Testing Laboratory Range PN-EN ISO 6507-1:2024-04","technique_en":"Vickers method","test_object_en":"Metals and their alloys and welded joints, unirradiated and irradiated","parameters_zh":[{"name":"范围","range":"HV 5, HV 10, HV 30"}],"search_zh":"未辐照与已辐照的金属及其合金以及焊接接头 维氏硬度 HV 维氏法 材料检验实验室 范围 PN-EN ISO 6507-1:2024-04","methodology_zh":"维氏硬度 HV","technique_zh":"维氏法","lab_section_zh":"材料检验实验室","test_object_zh":"未辐照与已辐照的金属及其合金以及焊接接头"},{"_id":"6a7d7289ec6a53014a48757d","lab_id":"69ad52a3de79e566650fb0d3","country":"PL","accr_number":"AB 025","accr_body":"PCA","test_object":"Metale i ich stopy oraz złącza spawane nienapromienione i napromienione","methodology":"Twardość HBW","parameters":[{"name":"Zakres","range":"HBW 2,5/187,5"}],"technique":"Metoda Brinella","techniques":["Metoda Brinella"],"computed":[],"activity":"Twardość HBW\nZakres HBW 2,5/187,5\nMetoda Brinella","reference":"PN-EN ISO 6506-1:2014-12","norm_bases":["PN-EN ISO 6506-1:2014-12"],"lab_section":"Laboratorium Badań Materiałowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Metale i ich stopy oraz złącza spawane nienapromienione i napromienione Twardość HBW\nZakres HBW 2,5/187,5\nMetoda Brinella PN-EN ISO 6506-1:2014-12 Metale i ich stopy oraz zlacza spawane nienapromienione i napromienione Twardosc HBW\nZakres HBW 2,5/187,5\nMetoda Brinella PN-EN ISO 6506-1:2014-12","categories":["materials"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Materials Testing Laboratory","methodology_en":"HBW hardness","parameters_en":[{"name":"Range","range":"HBW 2,5/187,5"}],"search_en":"Metals and their alloys and welded joints, unirradiated and irradiated HBW hardness Brinell method Materials Testing Laboratory Range PN-EN ISO 6506-1:2014-12","technique_en":"Brinell method","test_object_en":"Metals and their alloys and welded joints, unirradiated and irradiated","parameters_zh":[{"name":"范围","range":"HBW 2,5/187,5"}],"search_zh":"未辐照与已辐照的金属及其合金以及焊接接头 布氏硬度 HBW 布氏法 材料检验实验室 范围 PN-EN ISO 6506-1:2014-12","lab_section_zh":"材料检验实验室","methodology_zh":"布氏硬度 HBW","technique_zh":"布氏法","test_object_zh":"未辐照与已辐照的金属及其合金以及焊接接头"},{"_id":"6a7d7289ec6a53014a48757e","lab_id":"69ad52a3de79e566650fb0d3","country":"PL","accr_number":"AB 025","accr_body":"PCA","test_object":"Metale i ich stopy nienapromienione i napromienione","methodology":"Odporność materiału na pękanie:","parameters":[{"name":"współczynnik intensywności naprężeń KQ"},{"name":"krytyczny współczynnik intensywności naprężeń KQ - K1c"},{"name":"obciążenie statyczne","range":"do 100 kN,"},{"name":"obciążenie dynamiczne ± 50 kN,"},{"name":"rozwarcie próbki","range":"do 4 mm"},{"name":"Próba rozciągania lub zginania"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność materiału na pękanie:\nZakres:\nwspółczynnik intensywności naprężeń KQ\nkrytyczny współczynnik intensywności naprężeń KQ - K1c\nobciążenie statyczne do 100 kN,\nobciążenie dynamiczne ± 50 kN,\nrozwarcie próbki do 4 mm\nPróba rozciągania lub zginania","reference":"ASTM E399-24","norm_bases":["ASTM E399-24"],"lab_section":"Laboratorium Badań Materiałowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Metale i ich stopy nienapromienione i napromienione Odporność materiału na pękanie:\nZakres:\nwspółczynnik intensywności naprężeń KQ\nkrytyczny współczynnik intensywności naprężeń KQ - K1c\nobciążenie statyczne do 100 kN,\nobciążenie dynamiczne ± 50 kN,\nrozwarcie próbki do 4 mm\nPróba rozciągania lub zginania ASTM E399-24 Metale i ich stopy nienapromienione i napromienione Odpornosc materialu na pekanie:\nZakres:\nwspolczynnik intensywnosci naprezen KQ\nkrytyczny wspolczynnik intensywnosci naprezen KQ - K1c\nobciazenie statyczne do 100 kN,\nobciazenie dynamiczne ± 50 kN,\nrozwarcie probki do 4 mm\nProba rozciagania lub zginania ASTM E399-24","categories":["materials"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Materials Testing Laboratory","methodology_en":"Resistance of the material to cracking:","parameters_en":[{"name":"stress intensity factor KQ"},{"name":"critical stress intensity factor KQ - K1c"},{"name":"static load","range":"do 100 kN,"},{"name":"dynamic load ± 50 kN,"},{"name":"specimen opening","range":"do 4 mm"},{"name":"Tensile or bending test"}],"search_en":"Metals and their alloys, unirradiated and irradiated Resistance of the material to cracking: Materials Testing Laboratory stress intensity factor KQ critical stress intensity factor KQ - K1c static load dynamic load ± 50 kN, specimen opening Tensile or bending test ASTM E399-24","test_object_en":"Metals and their alloys, unirradiated and irradiated","lab_section_zh":"材料检验实验室","parameters_zh":[{"name":"współczynnik intensywności naprężeń KQ"},{"name":"krytyczny współczynnik intensywności naprężeń KQ - K1c"},{"name":"静载荷","range":"do 100 kN,"},{"name":"动荷载 ± 50 kN，"},{"name":"试样张开位移","range":"do 4 mm"},{"name":"拉伸或弯曲试验"}],"search_zh":"未辐照与已辐照的金属及其合金 材料检验实验室 静载荷 动荷载 ± 50 kN， 试样张开位移 拉伸或弯曲试验 ASTM E399-24","test_object_zh":"未辐照与已辐照的金属及其合金"},{"_id":"6a7d7289ec6a53014a48757f","lab_id":"69ad52a3de79e566650fb0d3","country":"PL","accr_number":"AB 025","accr_body":"PCA","test_object":"Metale i ich stopy nienapromienione i napromienione","methodology":"Prędkość rozwoju pęknięć zmęczeniowych da/dN metoda stałej amplitudy obciążeń (ΔK - increasing)","parameters":[{"name":"obciążenie statyczne","range":"do 100 kN,"},{"name":"obciążenie dynamiczne ± 50 kN,"},{"name":"rozwarcie próbki","range":"do 4 mm"},{"name":"Próba rozciągania lub zginania"}],"technique":null,"techniques":[],"computed":[],"activity":"Prędkość rozwoju pęknięć zmęczeniowych da/dN metoda stałej amplitudy obciążeń (ΔK - increasing)\nZakres:\nobciążenie statyczne do 100 kN,\nobciążenie dynamiczne ± 50 kN,\nrozwarcie próbki do 4 mm\nPróba rozciągania lub zginania","reference":"ISO 12108:2018","norm_bases":["ISO 12108:2018"],"lab_section":"Laboratorium Badań Materiałowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Metale i ich stopy nienapromienione i napromienione Prędkość rozwoju pęknięć zmęczeniowych da/dN metoda stałej amplitudy obciążeń (ΔK - increasing)\nZakres:\nobciążenie statyczne do 100 kN,\nobciążenie dynamiczne ± 50 kN,\nrozwarcie próbki do 4 mm\nPróba rozciągania lub zginania ISO 12108:2018 Metale i ich stopy nienapromienione i napromienione Predkosc rozwoju pekniec zmeczeniowych da/dN metoda stalej amplitudy obciazen (ΔK - increasing)\nZakres:\nobciazenie statyczne do 100 kN,\nobciazenie dynamiczne ± 50 kN,\nrozwarcie probki do 4 mm\nProba rozciagania lub zginania ISO 12108:2018","categories":["materials"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Materials Testing Laboratory","methodology_en":"Fatigue crack growth rate da/dN constant load amplitude method (ΔK - increasing)","parameters_en":[{"name":"static load","range":"do 100 kN,"},{"name":"dynamic load ± 50 kN,"},{"name":"specimen opening","range":"do 4 mm"},{"name":"Tensile or bending test"}],"search_en":"Metals and their alloys, unirradiated and irradiated Fatigue crack growth rate da/dN constant load amplitude method (ΔK - increasing) Materials Testing Laboratory static load dynamic load ± 50 kN, specimen opening Tensile or bending test ISO 12108:2018","test_object_en":"Metals and their alloys, unirradiated and irradiated","lab_section_zh":"材料检验实验室","parameters_zh":[{"name":"静载荷","range":"do 100 kN,"},{"name":"动荷载 ± 50 kN，"},{"name":"试样张开位移","range":"do 4 mm"},{"name":"拉伸或弯曲试验"}],"search_zh":"未辐照与已辐照的金属及其合金 材料检验实验室 静载荷 动荷载 ± 50 kN， 试样张开位移 拉伸或弯曲试验 ISO 12108:2018","test_object_zh":"未辐照与已辐照的金属及其合金"},{"_id":"6a7d7289ec6a53014a487580","lab_id":"69ad52a3de79e566650fb0d3","country":"PL","accr_number":"AB 025","accr_body":"PCA","test_object":"Metale i ich stopy nienapromienione i napromienione","methodology":"Rozwarcie szczeliny - δ","parameters":[{"name":"Krytyczna wartość rozwarcia szczeliny – δc metoda CTOD"},{"name":"obciążenie statyczne","range":"do 100 kN,"},{"name":"obciążenie dynamiczne ± 50 kN,"},{"name":"rozwarcie próbki","range":"do 4 mm"},{"name":"Próba rozciągania lub zginania"}],"technique":null,"techniques":[],"computed":[],"activity":"Rozwarcie szczeliny - δ\nZakres:\nKrytyczna wartość rozwarcia szczeliny – δc metoda CTOD\nobciążenie statyczne do 100 kN,\nobciążenie dynamiczne ± 50 kN,\nrozwarcie próbki do 4 mm\nPróba rozciągania lub zginania","reference":"BS 7448-1:1991","norm_bases":["BS 7448-1:1991"],"lab_section":"Laboratorium Badań Materiałowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Metale i ich stopy nienapromienione i napromienione Rozwarcie szczeliny - δ\nZakres:\nKrytyczna wartość rozwarcia szczeliny – δc metoda CTOD\nobciążenie statyczne do 100 kN,\nobciążenie dynamiczne ± 50 kN,\nrozwarcie próbki do 4 mm\nPróba rozciągania lub zginania BS 7448-1:1991 Metale i ich stopy nienapromienione i napromienione Rozwarcie szczeliny - δ\nZakres:\nKrytyczna wartosc rozwarcia szczeliny – δc metoda CTOD\nobciazenie statyczne do 100 kN,\nobciazenie dynamiczne ± 50 kN,\nrozwarcie probki do 4 mm\nProba rozciagania lub zginania BS 7448-1:1991","categories":["materials"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Materials Testing Laboratory","methodology_en":"Crack opening displacement - δ","parameters_en":[{"name":"Critical crack tip opening displacement – δc CTOD method"},{"name":"static load","range":"do 100 kN,"},{"name":"dynamic load ± 50 kN,"},{"name":"specimen opening","range":"do 4 mm"},{"name":"Tensile or bending test"}],"search_en":"Metals and their alloys, unirradiated and irradiated Crack opening displacement - δ Materials Testing Laboratory Critical crack tip opening displacement – δc CTOD method static load dynamic load ± 50 kN, specimen opening Tensile or bending test BS 7448-1:1991","test_object_en":"Metals and their alloys, unirradiated and irradiated","lab_section_zh":"材料检验实验室","parameters_zh":[{"name":"Krytyczna wartość rozwarcia szczeliny – δc metoda CTOD"},{"name":"静载荷","range":"do 100 kN,"},{"name":"动荷载 ± 50 kN，"},{"name":"试样张开位移","range":"do 4 mm"},{"name":"拉伸或弯曲试验"}],"search_zh":"未辐照与已辐照的金属及其合金 材料检验实验室 静载荷 动荷载 ± 50 kN， 试样张开位移 拉伸或弯曲试验 BS 7448-1:1991","test_object_zh":"未辐照与已辐照的金属及其合金"}],"has_pdf":true}