{"lab":{"_id":"69ad52a3de79e566650fb0cf","accr_number":"AB 023","country":"PL","accr_body":"PCA","address":"ZESPÓŁ LABORATORIÓW BADAWCZYCH, ul. Filtrowa 1, 00-611 Warszawa","categories":["construction","materials","water","electronics","environment"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":1154,"name":"INSTYTUT TECHNIKI BUDOWLANEJ","parse_status":"parsed","parse_version":3,"pdf_files":["AB_023.pdf"],"scope_summary":"","search_text":"instytut techniki budowlanej zespół laboratoriów badawczych, ul. filtrowa 1, 00-611 warszawa other materials metrology construction environment pharma water automotive electronics food","status":"active","updated_at":"2026-03-08T14:50:02.987Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:02.987Z","parse_date":"2026-07-17T16:18:57.370Z","parse_source":"m5-mistral-qa","email_confidence":"high","email_mx":true,"email_source":"https://www.itb.pl/kontakt/","fields_of_testing":[{"codes":"A/5","pl":"Badania akustyczne i drgań - wyrobów budowlanych, materiałów budowlanych, obiektów budowlanych","en":"Acoustic and vibration tests of building products, building materials, building items,"},{"codes":"C/4; C/5; C/9, C/21; C/27; C/45","pl":"Badania chemiczne wyrobów chemicznych, wyrobów budowlanych, materiałów budowlanych, obiektów budowlanych, powietrza, wyrobów z tworzyw sztucznych i gumy, drewna, farb i lakierów","en":"Chemical tests of chemical products, building products, building materials, building items, plastic and rubber products, wood, paints and varnishes"},{"codes":"E/54","pl":"Badania elektryczne i elektroniczne - wyrobów i wyposażenia elektronicznego","en":"Electric and electronic tests of electronic products and equipment"},{"codes":"F/54","pl":"Badania kompatybilności elektromagnetycznej (EMC) - wyrobów i wyposażenia elektronicznego","en":"Electromagnetic compatibility (EMC) tests of electronic products"},{"codes":"H/5; H/6; H/8; H/11; H/17; H/21; H/23; H/45; H/54","pl":"Badania ogniowe - wyrobów budowlanych, materiałów budowlanych, obiektów budowlanych, wyrobów i wyposażenia elektrycznego, wyrobów i materiałów konstrukcyjnych, mebli, wyrobów innych, wyrobów z tworzyw sztucznych i gumy, tekstyliów i skóry, farb i lakierów, wyrobów i wyposażenie elektronicznego","en":"Fire tests of building products, building materials, building items, electrical products and equipment, construction products and materials, furniture, plastic and rubber products, textiles and leather, paints and varnishes, electronic products and equipment"},{"codes":"J/5; J/8; J/12; J/21; J/27; J/31; J/54","pl":"Badania mechaniczne, badania metalograficzne - wyrobów budowlanych, materiałów budowlanych, obiektów budowlanych, wyrobów i materiałów konstrukcyjnych, szkła i ceramiki, wyrobów z tworzyw sztucznych i gumy, drewna, gleby, gruntów, skał, wyrobów i wyposażenia elektronicznego","en":"Mechanical tests, metallographic tests of building products, building materials, building items, construction products and materials, glass and ceramics, plastic and rubber products, wood, soil, rocks, electronic products and equipment"}],"issue":{"no":"31","date":"16.07.2025"},"map_coord":[52.21855,21.008598],"map_geo":"nominatim-street","has_en":true,"category_counts":{"other":710,"construction":250,"materials":151,"water":43,"electronics":25,"environment":8,"metrology":2,"microbiology":1},"category_scores":{"other":423.61,"construction":52.52,"materials":19.16,"water":1.55,"electronics":0.53,"environment":0.05,"metrology":0,"microbiology":0},"has_zh":true},"methods":[{"_id":"6a5a55f19af9f73f38250f14","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Budynki oraz części budynków","test_object_en":"Buildings and parts of buildings","methodology":"Szczelność budynku + Zakres: 5-8300CFM","methodology_en":"Building airtightness + Range: 5-8300CFM","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność budynku + Zakres: 5-8300CFM","reference":"PN-EN ISO 9972:2015-10","norm_bases":["PN-EN ISO 9972:2015-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Budynki oraz części budynków Szczelność budynku + Zakres: 5-8300CFM PN-EN ISO 9972:2015-10 Budynki oraz czesci budynkow Szczelnosc budynku + Zakres: 5-8300CFM PN-EN ISO 9972:2015-10","categories":["other"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Buildings and parts of buildings Building airtightness + Range: 5-8300CFM PN-EN ISO 9972:2015-10"},{"_id":"6a5a55f19af9f73f38250f15","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Balustrady i poręcze budowlane","test_object_en":"Building balustrades and handrails","methodology":"Oględziny zewnętrzne","methodology_en":"External visual examination","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Oględziny zewnętrzne","reference":"LZE-140/2/04-2019","norm_bases":["LZE-140/2/04-2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Balustrady i poręcze budowlane Oględziny zewnętrzne LZE-140/2/04-2019 Balustrady i porecze budowlane Ogledziny zewnetrzne LZE-140/2/04-2019","categories":["construction"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building balustrades and handrails External visual examination LZE-140/2/04-2019","search_zh":"建筑栏杆与扶手 LZE-140/2/04-2019","test_object_zh":"建筑栏杆与扶手"},{"_id":"6a5a55f19af9f73f38250f16","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Balustrady i poręcze budowlane","test_object_en":"Building balustrades and handrails","methodology":"Odporność na uderzenie ciałem miękkim i ciężkim Zakres: ciało udarowe - worek 30 kg","methodology_en":"Soft and heavy body impact resistance Range: impact body - bag 30 kg","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie ciałem miękkim i ciężkim Zakres: ciało udarowe - worek 30 kg","reference":"LZE-140/2/04-2019","norm_bases":["LZE-140/2/04-2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Balustrady i poręcze budowlane Odporność na uderzenie ciałem miękkim i ciężkim Zakres: ciało udarowe - worek 30 kg LZE-140/2/04-2019 Balustrady i porecze budowlane Odpornosc na uderzenie cialem miekkim i ciezkim Zakres: cialo udarowe - worek 30 kg LZE-140/2/04-2019","categories":["construction"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building balustrades and handrails Soft and heavy body impact resistance Range: impact body - bag 30 kg LZE-140/2/04-2019","search_zh":"建筑栏杆与扶手 LZE-140/2/04-2019","test_object_zh":"建筑栏杆与扶手"},{"_id":"6a5a55f19af9f73f38250f17","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Balustrady i poręcze budowlane","test_object_en":"Building balustrades and handrails","methodology":"Odporność na uderzenie ciałem miękkim i ciężkim Zakres: ciało udarowe - opona 50 kg","methodology_en":"Soft and heavy body impact resistance Range: impact body - tyre 50 kg","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie ciałem miękkim i ciężkim Zakres: ciało udarowe - opona 50 kg","reference":"LZE-140/2/04-2019","norm_bases":["LZE-140/2/04-2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Balustrady i poręcze budowlane Odporność na uderzenie ciałem miękkim i ciężkim Zakres: ciało udarowe - opona 50 kg LZE-140/2/04-2019 Balustrady i porecze budowlane Odpornosc na uderzenie cialem miekkim i ciezkim Zakres: cialo udarowe - opona 50 kg LZE-140/2/04-2019","categories":["construction"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building balustrades and handrails Soft and heavy body impact resistance Range: impact body - tyre 50 kg LZE-140/2/04-2019","search_zh":"建筑栏杆与扶手 LZE-140/2/04-2019","test_object_zh":"建筑栏杆与扶手"},{"_id":"6a5a55f19af9f73f38250f18","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Balustrady i poręcze budowlane","test_object_en":"Building balustrades and handrails","methodology":"Wytrzymałość na obciążenia statyczne Zakres: obciążenie do 3 kN/m Obciążenie statyczne","methodology_en":"Resistance to static loads Range: load up to 3 kN/m Static loading","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na obciążenia statyczne Zakres: obciążenie do 3 kN/m Obciążenie statyczne","reference":"LZE-140/2/04-2019","norm_bases":["LZE-140/2/04-2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Balustrady i poręcze budowlane Wytrzymałość na obciążenia statyczne Zakres: obciążenie do 3 kN/m Obciążenie statyczne LZE-140/2/04-2019 Balustrady i porecze budowlane Wytrzymalosc na obciazenia statyczne Zakres: obciazenie do 3 kN/m Obciazenie statyczne LZE-140/2/04-2019","categories":["construction"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building balustrades and handrails Resistance to static loads Range: load up to 3 kN/m Static loading LZE-140/2/04-2019","search_zh":"建筑栏杆与扶手 LZE-140/2/04-2019","test_object_zh":"建筑栏杆与扶手"},{"_id":"6a5a55f19af9f73f38250f19","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Balustrady i poręcze budowlane","test_object_en":"Building balustrades and handrails","methodology":"Odporność na uderzenie ciałem twardym Zakres: ciało udarowe - kula stalowa 0,5 kg","methodology_en":"Hard body impact resistance Range: impact body - steel ball 0,5 kg","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie ciałem twardym Zakres: ciało udarowe - kula stalowa 0,5 kg","reference":"LZE-140/2/04-2019","norm_bases":["LZE-140/2/04-2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Balustrady i poręcze budowlane Odporność na uderzenie ciałem twardym Zakres: ciało udarowe - kula stalowa 0,5 kg LZE-140/2/04-2019 Balustrady i porecze budowlane Odpornosc na uderzenie cialem twardym Zakres: cialo udarowe - kula stalowa 0,5 kg LZE-140/2/04-2019","categories":["materials","construction"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building balustrades and handrails Hard body impact resistance Range: impact body - steel ball 0,5 kg LZE-140/2/04-2019","search_zh":"建筑栏杆与扶手 LZE-140/2/04-2019","test_object_zh":"建筑栏杆与扶手"},{"_id":"6a5a55f19af9f73f38250f1a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Balustrady i poręcze budowlane","test_object_en":"Building balustrades and handrails","methodology":"Odporność na obciążenie wiatrem","methodology_en":"Resistance to wind load","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenie wiatrem","reference":"LZE-140/2/04-2019","norm_bases":["LZE-140/2/04-2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Balustrady i poręcze budowlane Odporność na obciążenie wiatrem LZE-140/2/04-2019 Balustrady i porecze budowlane Odpornosc na obciazenie wiatrem LZE-140/2/04-2019","categories":["construction"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building balustrades and handrails Resistance to wind load LZE-140/2/04-2019","search_zh":"建筑栏杆与扶手 抗风荷载性 LZE-140/2/04-2019","test_object_zh":"建筑栏杆与扶手","methodology_zh":"抗风荷载性"},{"_id":"6a5a55f19af9f73f38250f1b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Balustrady i poręcze budowlane","test_object_en":"Building balustrades and handrails","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary geometryczne","reference":"LZE-140/2/04-2019","norm_bases":["LZE-140/2/04-2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Balustrady i poręcze budowlane Wymiary geometryczne LZE-140/2/04-2019 Balustrady i porecze budowlane Wymiary geometryczne LZE-140/2/04-2019","categories":["construction"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building balustrades and handrails Geometric dimensions LZE-140/2/04-2019","methodology_zh":"几何尺寸","search_zh":"建筑栏杆与扶手 几何尺寸 LZE-140/2/04-2019","test_object_zh":"建筑栏杆与扶手"},{"_id":"6a5a55f19af9f73f38250f1c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Odporność na obciążenia statyczne działające prostopadle do płaszczyzny skrzydła Metoda obciążeń statycznych","methodology_en":"Resistance to static loads acting perpendicular to the plane of the leaf Static load method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenia statyczne działające prostopadle do płaszczyzny skrzydła Metoda obciążeń statycznych","reference":"LZE-120/4/04-2018","norm_bases":["LZE-120/4/04-2018"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odporność na obciążenia statyczne działające prostopadle do płaszczyzny skrzydła Metoda obciążeń statycznych LZE-120/4/04-2018 Drzwi, zespoly drzwiowe, skrzydla, oscieznice - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odpornosc na obciazenia statyczne dzialajace prostopadle do plaszczyzny skrzydla Metoda obciazen statycznych LZE-120/4/04-2018","categories":["other"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Resistance to static loads acting perpendicular to the plane of the leaf Static load method LZE-120/4/04-2018","search_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 LZE-120/4/04-2018","test_object_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用"},{"_id":"6a5a55f19af9f73f38250f1d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Odporność na wstrząsy","methodology_en":"Shock resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na wstrząsy","reference":"LZE-078/9/04-2018 | LZE-120/4/04-2018 | LZE-123/3/04-2018","norm_bases":["LZE-078/9/04-2018","LZE-120/4/04-2018","LZE-123/3/04-2018"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odporność na wstrząsy LZE-078/9/04-2018 | LZE-120/4/04-2018 | LZE-123/3/04-2018 Drzwi, zespoly drzwiowe, skrzydla, oscieznice - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odpornosc na wstrzasy LZE-078/9/04-2018 | LZE-120/4/04-2018 | LZE-123/3/04-2018","categories":["other"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Shock resistance LZE-078/9/04-2018 | LZE-120/4/04-2018 | LZE-123/3/04-2018","search_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 耐振动性 LZE-078/9/04-2018 | LZE-120/4/04-2018 | LZE-123/3/04-2018","test_object_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用","methodology_zh":"耐振动性"},{"_id":"6a5a55f19af9f73f38250f1e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Odporność na obciążenie statyczne pionowe działające w płaszczyźnie skrzydła Metoda obciążeń statycznych","methodology_en":"Resistance to vertical static load acting in the plane of the leaf Static load method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenie statyczne pionowe działające w płaszczyźnie skrzydła Metoda obciążeń statycznych","reference":"LZE-122/3/04-2018 | LZE-123/3/04-2018","norm_bases":["LZE-122/3/04-2018","LZE-123/3/04-2018"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odporność na obciążenie statyczne pionowe działające w płaszczyźnie skrzydła Metoda obciążeń statycznych LZE-122/3/04-2018 | LZE-123/3/04-2018 Drzwi, zespoly drzwiowe, skrzydla, oscieznice - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odpornosc na obciazenie statyczne pionowe dzialajace w plaszczyznie skrzydla Metoda obciazen statycznych LZE-122/3/04-2018 | LZE-123/3/04-2018","categories":["other"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Resistance to vertical static load acting in the plane of the leaf Static load method LZE-122/3/04-2018 | LZE-123/3/04-2018","search_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 LZE-122/3/04-2018 | LZE-123/3/04-2018","test_object_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用"},{"_id":"6a5a55f19af9f73f38250f1f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Odporność na uderzenie ciałem miękkim i ciężkim Zakres: ciało o masie 30 kg lub 50 kg","methodology_en":"Soft and heavy body impact resistance Range: body with a mass of 30 kg or 50 kg","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie ciałem miękkim i ciężkim Zakres: ciało o masie 30 kg lub 50 kg","reference":"LZE-123/3/04-2018 | LZE-120/4/04-2018","norm_bases":["LZE-123/3/04-2018","LZE-120/4/04-2018"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odporność na uderzenie ciałem miękkim i ciężkim Zakres: ciało o masie 30 kg lub 50 kg LZE-123/3/04-2018 | LZE-120/4/04-2018 Drzwi, zespoly drzwiowe, skrzydla, oscieznice - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odpornosc na uderzenie cialem miekkim i ciezkim Zakres: cialo o masie 30 kg lub 50 kg LZE-123/3/04-2018 | LZE-120/4/04-2018","categories":["other"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Soft and heavy body impact resistance Range: body with a mass of 30 kg or 50 kg LZE-123/3/04-2018 | LZE-120/4/04-2018","search_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 LZE-123/3/04-2018 | LZE-120/4/04-2018","test_object_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用"},{"_id":"6a5a55f19af9f73f38250f20","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Odporność na uderzenie ciałem twardym","methodology_en":"Resistance to hard body impact","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie ciałem twardym","reference":"LZE-122/3/04-2018","norm_bases":["LZE-122/3/04-2018"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odporność na uderzenie ciałem twardym LZE-122/3/04-2018 Drzwi, zespoly drzwiowe, skrzydla, oscieznice - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odpornosc na uderzenie cialem twardym LZE-122/3/04-2018","categories":["other"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Resistance to hard body impact LZE-122/3/04-2018","search_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 硬物撞击抗力 LZE-122/3/04-2018","test_object_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用","methodology_zh":"硬物撞击抗力"},{"_id":"6a5a55f19af9f73f38250f21","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Odporność na wielokrotne otwieranie i zamykanie Metoda ręcznej manipulacji","methodology_en":"Resistance to repeated opening and closing Manual manipulation method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na wielokrotne otwieranie i zamykanie Metoda ręcznej manipulacji","reference":"LZE-120/4/04-2018 | LZE-122/3/04-2018 | LZE-123/3/04-2018","norm_bases":["LZE-120/4/04-2018","LZE-122/3/04-2018","LZE-123/3/04-2018"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odporność na wielokrotne otwieranie i zamykanie Metoda ręcznej manipulacji LZE-120/4/04-2018 | LZE-122/3/04-2018 | LZE-123/3/04-2018 Drzwi, zespoly drzwiowe, skrzydla, oscieznice - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odpornosc na wielokrotne otwieranie i zamykanie Metoda recznej manipulacji LZE-120/4/04-2018 | LZE-122/3/04-2018 | LZE-123/3/04-2018","categories":["other"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Resistance to repeated opening and closing Manual manipulation method LZE-120/4/04-2018 | LZE-122/3/04-2018 | LZE-123/3/04-2018","search_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 LZE-120/4/04-2018 | LZE-122/3/04-2018 | LZE-123/3/04-2018","test_object_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用"},{"_id":"6a5a55f19af9f73f38250f22","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Siła potrzebna do maksymalnego rozwarcia skrzydła od położenia zamkniętego","methodology_en":"Force needed to open the leaf fully from the closed position","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła potrzebna do maksymalnego rozwarcia skrzydła od położenia zamkniętego","reference":"LZE-123/3/04-2018","norm_bases":["LZE-123/3/04-2018"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Siła potrzebna do maksymalnego rozwarcia skrzydła od położenia zamkniętego LZE-123/3/04-2018 Drzwi, zespoly drzwiowe, skrzydla, oscieznice - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Sila potrzebna do maksymalnego rozwarcia skrzydla od polozenia zamknietego LZE-123/3/04-2018","categories":["other"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Force needed to open the leaf fully from the closed position LZE-123/3/04-2018","search_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 LZE-123/3/04-2018","test_object_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用"},{"_id":"6a5a55f19af9f73f38250f23","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Wielkość szczeliny przylgowej i luzu wrębowego","methodology_en":"Size of the rebate gap and the rebate clearance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wielkość szczeliny przylgowej i luzu wrębowego","reference":"LZE-078/9/04-2018","norm_bases":["LZE-078/9/04-2018"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wielkość szczeliny przylgowej i luzu wrębowego LZE-078/9/04-2018 Drzwi, zespoly drzwiowe, skrzydla, oscieznice - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wielkosc szczeliny przylgowej i luzu wrebowego LZE-078/9/04-2018","categories":["other"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Size of the rebate gap and the rebate clearance LZE-078/9/04-2018","search_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 LZE-078/9/04-2018","test_object_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用"},{"_id":"6a5a55f19af9f73f38250f24","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Wykonanie drzwi Metoda wizualna","methodology_en":"Door workmanship Visual method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wykonanie drzwi Metoda wizualna","reference":"LZE-078/9/04-2018 | LZE-120/4/04-2018 | LZE-122/3/04-2018 | LZE-123/3/04-2018","norm_bases":["LZE-078/9/04-2018","LZE-120/4/04-2018","LZE-122/3/04-2018","LZE-123/3/04-2018"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wykonanie drzwi Metoda wizualna LZE-078/9/04-2018 | LZE-120/4/04-2018 | LZE-122/3/04-2018 | LZE-123/3/04-2018 Drzwi, zespoly drzwiowe, skrzydla, oscieznice - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wykonanie drzwi Metoda wizualna LZE-078/9/04-2018 | LZE-120/4/04-2018 | LZE-122/3/04-2018 | LZE-123/3/04-2018","categories":["other"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Door workmanship Visual method LZE-078/9/04-2018 | LZE-120/4/04-2018 | LZE-122/3/04-2018 | LZE-123/3/04-2018","search_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 LZE-078/9/04-2018 | LZE-120/4/04-2018 | LZE-122/3/04-2018 | LZE-123/3/04-2018","test_object_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用"},{"_id":"6a5a55f19af9f73f38250f25","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Wymiary liniowe ościeżnic Metoda pomiaru liniowego","methodology_en":"Linear dimensions of door frames Linear measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary liniowe ościeżnic Metoda pomiaru liniowego","reference":"LZE-078/9/04-2018 | LZE-122/3/04-2018 | LZE-123/3/04-2018","norm_bases":["LZE-078/9/04-2018","LZE-122/3/04-2018","LZE-123/3/04-2018"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wymiary liniowe ościeżnic Metoda pomiaru liniowego LZE-078/9/04-2018 | LZE-122/3/04-2018 | LZE-123/3/04-2018 Drzwi, zespoly drzwiowe, skrzydla, oscieznice - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wymiary liniowe oscieznic Metoda pomiaru liniowego LZE-078/9/04-2018 | LZE-122/3/04-2018 | LZE-123/3/04-2018","categories":["other"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Linear dimensions of door frames Linear measurement method LZE-078/9/04-2018 | LZE-122/3/04-2018 | LZE-123/3/04-2018","search_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 LZE-078/9/04-2018 | LZE-122/3/04-2018 | LZE-123/3/04-2018","test_object_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用"},{"_id":"6a5a55f19af9f73f38250f26","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Wytrzymałość połączeń skrzydełek zawiasów z ościeżnicą na obciążenia dopuszczalne Metoda obciążeń statycznych","methodology_en":"Strength of the connections of the hinge leaves to the frame under permissible loads Static loading method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość połączeń skrzydełek zawiasów z ościeżnicą na obciążenia dopuszczalne Metoda obciążeń statycznych","reference":"LZE-078/9/04-2018","norm_bases":["LZE-078/9/04-2018"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wytrzymałość połączeń skrzydełek zawiasów z ościeżnicą na obciążenia dopuszczalne Metoda obciążeń statycznych LZE-078/9/04-2018 Drzwi, zespoly drzwiowe, skrzydla, oscieznice - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wytrzymalosc polaczen skrzydelek zawiasow z oscieznica na obciazenia dopuszczalne Metoda obciazen statycznych LZE-078/9/04-2018","categories":["other"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Strength of the connections of the hinge leaves to the frame under permissible loads Static loading method LZE-078/9/04-2018","search_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 LZE-078/9/04-2018","test_object_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用"},{"_id":"6a5a55f19af9f73f38250f27","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Prawidłowość działania","methodology_en":"Correct operation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Prawidłowość działania","reference":"LZE-078/9/04-2018 | LZE-120/4/04-2018 | LZE-122/3/04-2018 | LZE-123/3/04-2018","norm_bases":["LZE-078/9/04-2018","LZE-120/4/04-2018","LZE-122/3/04-2018","LZE-123/3/04-2018"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Prawidłowość działania LZE-078/9/04-2018 | LZE-120/4/04-2018 | LZE-122/3/04-2018 | LZE-123/3/04-2018 Drzwi, zespoly drzwiowe, skrzydla, oscieznice - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Prawidlowosc dzialania LZE-078/9/04-2018 | LZE-120/4/04-2018 | LZE-122/3/04-2018 | LZE-123/3/04-2018","categories":["other"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Correct operation LZE-078/9/04-2018 | LZE-120/4/04-2018 | LZE-122/3/04-2018 | LZE-123/3/04-2018","search_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 LZE-078/9/04-2018 | LZE-120/4/04-2018 | LZE-122/3/04-2018 | LZE-123/3/04-2018","test_object_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用"},{"_id":"6a5a55f19af9f73f38250f28","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Przepuszczalność powietrza przy określonej różnicy ciśnień +","methodology_en":"Air permeability at a specified pressure difference +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność powietrza przy określonej różnicy ciśnień +","reference":"ASTM E283/E283M-19","norm_bases":["ASTM E283/E283M-19"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Przepuszczalność powietrza przy określonej różnicy ciśnień + ASTM E283/E283M-19 Drzwi, zespoly drzwiowe, skrzydla, oscieznice - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Przepuszczalnosc powietrza przy okreslonej roznicy cisnien + ASTM E283/E283M-19","categories":["other"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Air permeability at a specified pressure difference + ASTM E283/E283M-19","search_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 规定压差下的透气性 + ASTM E283/E283M-19","test_object_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用","methodology_zh":"规定压差下的透气性 +"},{"_id":"6a5a55f19af9f73f38250f29","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Siła potrzebna do zaryglowania drzwi +","methodology_en":"Force needed to bolt the door +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła potrzebna do zaryglowania drzwi +","reference":"AAMA/WDMA/CSA 101/I.S.2/A440- 22","norm_bases":["AAMA/WDMA/CSA 101/I.S.2/A440- 22"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Siła potrzebna do zaryglowania drzwi + AAMA/WDMA/CSA 101/I.S.2/A440- 22 Drzwi, zespoly drzwiowe, skrzydla, oscieznice - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Sila potrzebna do zaryglowania drzwi + AAMA/WDMA/CSA 101/I.S.2/A440- 22","categories":["other"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Force needed to bolt the door + AAMA/WDMA/CSA 101/I.S.2/A440- 22","search_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 AAMA/WDMA/CSA 101/I.S.2/A440- 22","test_object_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用"},{"_id":"6a5a55f19af9f73f38250f2a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Siły operacyjne +","methodology_en":"Operating forces +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siły operacyjne +","reference":"AAMA/WDMA/CSA 101/I.S.2/A440- 22+ ASTM E2068-00(2022)","norm_bases":["AAMA/WDMA/CSA 101/I.S.2/A440- 22+ ASTM E2068-00(2022)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Siły operacyjne + AAMA/WDMA/CSA 101/I.S.2/A440- 22+ ASTM E2068-00(2022) Drzwi, zespoly drzwiowe, skrzydla, oscieznice - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Sily operacyjne + AAMA/WDMA/CSA 101/I.S.2/A440- 22+ ASTM E2068-00(2022)","categories":["other"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Operating forces + AAMA/WDMA/CSA 101/I.S.2/A440- 22+ ASTM E2068-00(2022)","search_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 操作力 + AAMA/WDMA/CSA 101/I.S.2/A440- 22+ ASTM E2068-00(2022)","test_object_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用","methodology_zh":"操作力 +"},{"_id":"6a5a55f19af9f73f38250f2b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Sztywność i wytrzymałość przy obciążeniu ciśnieniem statycznym +","methodology_en":"Stiffness and strength under static pressure loading +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sztywność i wytrzymałość przy obciążeniu ciśnieniem statycznym +","reference":"ASTM E330/E330M-14(2021)","norm_bases":["ASTM E330/E330M-14(2021)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Sztywność i wytrzymałość przy obciążeniu ciśnieniem statycznym + ASTM E330/E330M-14(2021) Drzwi, zespoly drzwiowe, skrzydla, oscieznice - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Sztywnosc i wytrzymalosc przy obciazeniu cisnieniem statycznym + ASTM E330/E330M-14(2021)","categories":["other"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Stiffness and strength under static pressure loading + ASTM E330/E330M-14(2021)","search_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 静压荷载下的刚度与强度 + ASTM E330/E330M-14(2021)","test_object_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用","methodology_zh":"静压荷载下的刚度与强度 +"},{"_id":"6a5a55f19af9f73f38250f2c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Wodoszczelność przy cyklicznej statycznej różnicy ciśnień +","methodology_en":"Watertightness under cyclic static pressure difference +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność przy cyklicznej statycznej różnicy ciśnień +","reference":"ASTM E547-00(2016)","norm_bases":["ASTM E547-00(2016)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wodoszczelność przy cyklicznej statycznej różnicy ciśnień + ASTM E547-00(2016) Drzwi, zespoly drzwiowe, skrzydla, oscieznice - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wodoszczelnosc przy cyklicznej statycznej roznicy cisnien + ASTM E547-00(2016)","categories":["other"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Watertightness under cyclic static pressure difference + ASTM E547-00(2016)","search_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 循环静压差下的水密性 + ASTM E547-00(2016)","test_object_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用","methodology_zh":"循环静压差下的水密性 +"},{"_id":"6a5a55f19af9f73f38250f2d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Wodoszczelność przy statycznej różnicy ciśnień +","methodology_en":"Watertightness under static pressure difference +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność przy statycznej różnicy ciśnień +","reference":"ASTM E331-00(2023)","norm_bases":["ASTM E331-00(2023)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wodoszczelność przy statycznej różnicy ciśnień + ASTM E331-00(2023) Drzwi, zespoly drzwiowe, skrzydla, oscieznice - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wodoszczelnosc przy statycznej roznicy cisnien + ASTM E331-00(2023)","categories":["other"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Watertightness under static pressure difference + ASTM E331-00(2023)","search_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 静压差下的水密性 + ASTM E331-00(2023)","test_object_zh":"门、门组件、门扇、门框 — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用","methodology_zh":"静压差下的水密性 +"},{"_id":"6a5a55f19af9f73f38250f2e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy budynków - ściany - ściany działowe - ściany osłonowe - dachy - przekrycia - inne","test_object_en":"Building elements - walls - partition walls - curtain walls - roofs - roof coverings - other","methodology":"Odporność na obciążenie poziome i ciężar własny Metoda obliczeniowa","methodology_en":"Resistance to horizontal load and self-weight Calculation method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenie poziome i ciężar własny Metoda obliczeniowa","reference":"PN-EN 13830:2005 „N” PB LK-131/2/02-2015","norm_bases":["PN-EN 13830:2005 „N” PB LK-131/2/02-2015"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy budynków - ściany - ściany działowe - ściany osłonowe - dachy - przekrycia - inne Odporność na obciążenie poziome i ciężar własny Metoda obliczeniowa PN-EN 13830:2005 „N” PB LK-131/2/02-2015 Elementy budynkow - sciany - sciany dzialowe - sciany oslonowe - dachy - przekrycia - inne Odpornosc na obciazenie poziome i ciezar wlasny Metoda obliczeniowa PN-EN 13830:2005 „N” PB LK-131/2/02-2015","categories":["construction"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building elements - walls - partition walls - curtain walls - roofs - roof coverings - other Resistance to horizontal load and self-weight Calculation method PN-EN 13830:2005 „N” PB LK-131/2/02-2015","search_zh":"建筑构件 － 墙体 － 隔墙 － 幕墙 － 屋面 － 覆盖结构 － 其他 PN-EN 13830:2005 „N” PB LK-131/2/02-2015","test_object_zh":"建筑构件 － 墙体 － 隔墙 － 幕墙 － 屋面 － 覆盖结构 － 其他"},{"_id":"6a5a55f19af9f73f38250f2f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy budynków - ściany - ściany działowe - ściany osłonowe - dachy - przekrycia - inne","test_object_en":"Building elements - walls - partition walls - curtain walls - roofs - roof coverings - other","methodology":"Opór na zacinający deszcz Zakres: ciśnienie do 5000 Pa","methodology_en":"Resistance to driving rain Range: pressure up to 5000 Pa","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Opór na zacinający deszcz Zakres: ciśnienie do 5000 Pa","reference":"PN-EN 12865:2004 Procedura A","norm_bases":["PN-EN 12865:2004 Procedura A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy budynków - ściany - ściany działowe - ściany osłonowe - dachy - przekrycia - inne Opór na zacinający deszcz Zakres: ciśnienie do 5000 Pa PN-EN 12865:2004 Procedura A Elementy budynkow - sciany - sciany dzialowe - sciany oslonowe - dachy - przekrycia - inne Opor na zacinajacy deszcz Zakres: cisnienie do 5000 Pa PN-EN 12865:2004 Procedura A","categories":["construction"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building elements - walls - partition walls - curtain walls - roofs - roof coverings - other Resistance to driving rain Range: pressure up to 5000 Pa PN-EN 12865:2004 Procedura A","search_zh":"建筑构件 － 墙体 － 隔墙 － 幕墙 － 屋面 － 覆盖结构 － 其他 PN-EN 12865:2004 Procedura A","test_object_zh":"建筑构件 － 墙体 － 隔墙 － 幕墙 － 屋面 － 覆盖结构 － 其他"},{"_id":"6a5a55f19af9f73f38250f30","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy budynków - ściany - ściany działowe - ściany osłonowe - dachy - przekrycia - inne","test_object_en":"Building elements - walls - partition walls - curtain walls - roofs - roof coverings - other","methodology":"Wodoszczelność pod ciśnieniem dynamicznym powietrza i natryskiem wodnym +","methodology_en":"Watertightness under dynamic air pressure and water spray +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność pod ciśnieniem dynamicznym powietrza i natryskiem wodnym +","reference":"PN-EN 13050:2011","norm_bases":["PN-EN 13050:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy budynków - ściany - ściany działowe - ściany osłonowe - dachy - przekrycia - inne Wodoszczelność pod ciśnieniem dynamicznym powietrza i natryskiem wodnym + PN-EN 13050:2011 Elementy budynkow - sciany - sciany dzialowe - sciany oslonowe - dachy - przekrycia - inne Wodoszczelnosc pod cisnieniem dynamicznym powietrza i natryskiem wodnym + PN-EN 13050:2011","categories":["construction"],"row_index":28,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building elements - walls - partition walls - curtain walls - roofs - roof coverings - other Watertightness under dynamic air pressure and water spray + PN-EN 13050:2011","search_zh":"建筑构件 － 墙体 － 隔墙 － 幕墙 － 屋面 － 覆盖结构 － 其他 PN-EN 13050:2011","test_object_zh":"建筑构件 － 墙体 － 隔墙 － 幕墙 － 屋面 － 覆盖结构 － 其他"},{"_id":"6a5a55f19af9f73f38250f31","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy budynków - ściany - ściany działowe - ściany osłonowe - dachy - przekrycia - inne","test_object_en":"Building elements - walls - partition walls - curtain walls - roofs - roof coverings - other","methodology":"Odporność na działanie liniowej siły poziomej Zakres: do 5 kN","methodology_en":"Resistance to a linear horizontal force Range: up to 5 kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie liniowej siły poziomej Zakres: do 5 kN","reference":"LZE-105/2/04-2019","norm_bases":["LZE-105/2/04-2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy budynków - ściany - ściany działowe - ściany osłonowe - dachy - przekrycia - inne Odporność na działanie liniowej siły poziomej Zakres: do 5 kN LZE-105/2/04-2019 Elementy budynkow - sciany - sciany dzialowe - sciany oslonowe - dachy - przekrycia - inne Odpornosc na dzialanie liniowej sily poziomej Zakres: do 5 kN LZE-105/2/04-2019","categories":["construction"],"row_index":29,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building elements - walls - partition walls - curtain walls - roofs - roof coverings - other Resistance to a linear horizontal force Range: up to 5 kN LZE-105/2/04-2019","search_zh":"建筑构件 － 墙体 － 隔墙 － 幕墙 － 屋面 － 覆盖结构 － 其他 LZE-105/2/04-2019","test_object_zh":"建筑构件 － 墙体 － 隔墙 － 幕墙 － 屋面 － 覆盖结构 － 其他"},{"_id":"6a5a55f19af9f73f38250f32","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy budynków - ściany - ściany działowe - ściany osłonowe - dachy - przekrycia - inne","test_object_en":"Building elements - walls - partition walls - curtain walls - roofs - roof coverings - other","methodology":"Wodoszczelność Metoda poligonowa +","methodology_en":"Watertightness Field test method +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność Metoda poligonowa +","reference":"AAMA 501.2","norm_bases":["AAMA 501.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy budynków - ściany - ściany działowe - ściany osłonowe - dachy - przekrycia - inne Wodoszczelność Metoda poligonowa + AAMA 501.2 Elementy budynkow - sciany - sciany dzialowe - sciany oslonowe - dachy - przekrycia - inne Wodoszczelnosc Metoda poligonowa + AAMA 501.2","categories":["construction"],"row_index":30,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building elements - walls - partition walls - curtain walls - roofs - roof coverings - other Watertightness Field test method + AAMA 501.2","search_zh":"建筑构件 － 墙体 － 隔墙 － 幕墙 － 屋面 － 覆盖结构 － 其他 AAMA 501.2","test_object_zh":"建筑构件 － 墙体 － 隔墙 － 幕墙 － 屋面 － 覆盖结构 － 其他"},{"_id":"6a5a55f19af9f73f38250f33","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Ściany osłonowe","test_object_en":"Curtain walling","methodology":"Odporność na obciążenie pionowe, Metoda A Zakres: siła od 0 do 20 kN, Przemieszczenie: od 0 do 50 mm","methodology_en":"Resistance to vertical load, Method A Range: force from 0 to 20 kN, Displacement: from 0 to 50 mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenie pionowe, Metoda A Zakres: siła od 0 do 20 kN, Przemieszczenie: od 0 do 50 mm","reference":"PN-EN 16758:2021-10","norm_bases":["PN-EN 16758:2021-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ściany osłonowe Odporność na obciążenie pionowe, Metoda A Zakres: siła od 0 do 20 kN, Przemieszczenie: od 0 do 50 mm PN-EN 16758:2021-10 Sciany oslonowe Odpornosc na obciazenie pionowe, Metoda A Zakres: sila od 0 do 20 kN, Przemieszczenie: od 0 do 50 mm PN-EN 16758:2021-10","categories":["other"],"row_index":31,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Curtain walling Resistance to vertical load, Method A Range: force from 0 to 20 kN, Displacement: from 0 to 50 mm PN-EN 16758:2021-10","search_zh":"幕墙 PN-EN 16758:2021-10","test_object_zh":"幕墙"},{"_id":"6a5a55f19af9f73f38250f34","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Ściany osłonowe","test_object_en":"Curtain walling","methodology":"Odporność na obciążenie poziome, Metoda A Zakres: siła od 0 do 20 kN, Przemieszczenie: od 0 do 50 mm","methodology_en":"Resistance to horizontal load, Method A Range: force from 0 to 20 kN, Displacement: from 0 to 50 mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenie poziome, Metoda A Zakres: siła od 0 do 20 kN, Przemieszczenie: od 0 do 50 mm","reference":"PN-EN 16758:2021-10","norm_bases":["PN-EN 16758:2021-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ściany osłonowe Odporność na obciążenie poziome, Metoda A Zakres: siła od 0 do 20 kN, Przemieszczenie: od 0 do 50 mm PN-EN 16758:2021-10 Sciany oslonowe Odpornosc na obciazenie poziome, Metoda A Zakres: sila od 0 do 20 kN, Przemieszczenie: od 0 do 50 mm PN-EN 16758:2021-10","categories":["other"],"row_index":32,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Curtain walling Resistance to horizontal load, Method A Range: force from 0 to 20 kN, Displacement: from 0 to 50 mm PN-EN 16758:2021-10","search_zh":"幕墙 PN-EN 16758:2021-10","test_object_zh":"幕墙"},{"_id":"6a5a55f19af9f73f38250f35","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Ściany osłonowe","test_object_en":"Curtain walling","methodology":"Przepuszczalność powietrza przy określonej różnicy ciśnień +","methodology_en":"Air permeability at a specified pressure difference +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność powietrza przy określonej różnicy ciśnień +","reference":"ASTM E283/E283M-19","norm_bases":["ASTM E283/E283M-19"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ściany osłonowe Przepuszczalność powietrza przy określonej różnicy ciśnień + ASTM E283/E283M-19 Sciany oslonowe Przepuszczalnosc powietrza przy okreslonej roznicy cisnien + ASTM E283/E283M-19","categories":["other"],"row_index":33,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Curtain walling Air permeability at a specified pressure difference + ASTM E283/E283M-19","search_zh":"幕墙 规定压差下的透气性 + ASTM E283/E283M-19","test_object_zh":"幕墙","methodology_zh":"规定压差下的透气性 +"},{"_id":"6a5a55f19af9f73f38250f36","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Ściany osłonowe","test_object_en":"Curtain walling","methodology":"Sztywność i wytrzymałość przy obciążeniu ciśnieniem statycznym +","methodology_en":"Stiffness and strength under static pressure loading +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sztywność i wytrzymałość przy obciążeniu ciśnieniem statycznym +","reference":"ASTM E330/E330M-14(2021)","norm_bases":["ASTM E330/E330M-14(2021)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ściany osłonowe Sztywność i wytrzymałość przy obciążeniu ciśnieniem statycznym + ASTM E330/E330M-14(2021) Sciany oslonowe Sztywnosc i wytrzymalosc przy obciazeniu cisnieniem statycznym + ASTM E330/E330M-14(2021)","categories":["other"],"row_index":34,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Curtain walling Stiffness and strength under static pressure loading + ASTM E330/E330M-14(2021)","search_zh":"幕墙 静压荷载下的刚度与强度 + ASTM E330/E330M-14(2021)","test_object_zh":"幕墙","methodology_zh":"静压荷载下的刚度与强度 +"},{"_id":"6a5a55f19af9f73f38250f37","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Ściany osłonowe","test_object_en":"Curtain walling","methodology":"Wodoszczelność przy cyklicznej statycznej różnicy ciśnień +","methodology_en":"Watertightness under cyclic static pressure difference +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność przy cyklicznej statycznej różnicy ciśnień +","reference":"ASTM E547-00(2016)","norm_bases":["ASTM E547-00(2016)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ściany osłonowe Wodoszczelność przy cyklicznej statycznej różnicy ciśnień + ASTM E547-00(2016) Sciany oslonowe Wodoszczelnosc przy cyklicznej statycznej roznicy cisnien + ASTM E547-00(2016)","categories":["other"],"row_index":35,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Curtain walling Watertightness under cyclic static pressure difference + ASTM E547-00(2016)","search_zh":"幕墙 循环静压差下的水密性 + ASTM E547-00(2016)","test_object_zh":"幕墙","methodology_zh":"循环静压差下的水密性 +"},{"_id":"6a5a55f19af9f73f38250f38","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Ściany osłonowe","test_object_en":"Curtain walling","methodology":"Wodoszczelność przy statycznej różnicy ciśnień +","methodology_en":"Watertightness under static pressure difference +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność przy statycznej różnicy ciśnień +","reference":"ASTM E331-00(2023)","norm_bases":["ASTM E331-00(2023)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ściany osłonowe Wodoszczelność przy statycznej różnicy ciśnień + ASTM E331-00(2023) Sciany oslonowe Wodoszczelnosc przy statycznej roznicy cisnien + ASTM E331-00(2023)","categories":["other"],"row_index":36,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Curtain walling Watertightness under static pressure difference + ASTM E331-00(2023)","search_zh":"幕墙 静压差下的水密性 + ASTM E331-00(2023)","test_object_zh":"幕墙","methodology_zh":"静压差下的水密性 +"},{"_id":"6a5a55f19af9f73f38250f39","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty kompozytowe","test_object_en":"Composite panels","methodology":"Cykle badań klimatycznych","methodology_en":"Climatic test cycles","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cykle badań klimatycznych","reference":"ETAG 016:2004 cz. 2 ETAG 016:2004 cz. 3","norm_bases":["ETAG 016:2004 cz. 2 ETAG 016:2004 cz. 3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty kompozytowe Cykle badań klimatycznych ETAG 016:2004 cz. 2 ETAG 016:2004 cz. 3 Plyty kompozytowe Cykle badan klimatycznych ETAG 016:2004 cz. 2 ETAG 016:2004 cz. 3","categories":["materials"],"row_index":37,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Composite panels Climatic test cycles ETAG 016:2004 cz. 2 ETAG 016:2004 cz. 3","search_zh":"复合板 ETAG 016:2004 cz. 2 ETAG 016:2004 cz. 3","test_object_zh":"复合板"},{"_id":"6a5a55f19af9f73f38250f3a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty kompozytowe","test_object_en":"Composite panels","methodology":"Nośność płyty swobodnie podpartej na obciążenia działające do podpory Metoda zginania","methodology_en":"Load-bearing capacity of a simply supported slab under loads acting towards the support Bending method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność płyty swobodnie podpartej na obciążenia działające do podpory Metoda zginania","reference":"ETAG 016:2004 cz. 1","norm_bases":["ETAG 016:2004 cz. 1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty kompozytowe Nośność płyty swobodnie podpartej na obciążenia działające do podpory Metoda zginania ETAG 016:2004 cz. 1 Plyty kompozytowe Nosnosc plyty swobodnie podpartej na obciazenia dzialajace do podpory Metoda zginania ETAG 016:2004 cz. 1","categories":["materials"],"row_index":38,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Composite panels Load-bearing capacity of a simply supported slab under loads acting towards the support Bending method ETAG 016:2004 cz. 1","search_zh":"复合板 ETAG 016:2004 cz. 1","test_object_zh":"复合板"},{"_id":"6a5a55f19af9f73f38250f3b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty kompozytowe","test_object_en":"Composite panels","methodology":"Nośność płyty zamocowanej przy obciążeniach działających od podpory Metoda zginania","methodology_en":"Load-bearing capacity of a fixed slab under loads acting away from the support Bending method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność płyty zamocowanej przy obciążeniach działających od podpory Metoda zginania","reference":"ETAG 016:2004 cz. 1","norm_bases":["ETAG 016:2004 cz. 1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty kompozytowe Nośność płyty zamocowanej przy obciążeniach działających od podpory Metoda zginania ETAG 016:2004 cz. 1 Plyty kompozytowe Nosnosc plyty zamocowanej przy obciazeniach dzialajacych od podpory Metoda zginania ETAG 016:2004 cz. 1","categories":["materials"],"row_index":39,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Composite panels Load-bearing capacity of a fixed slab under loads acting away from the support Bending method ETAG 016:2004 cz. 1","search_zh":"复合板 ETAG 016:2004 cz. 1","test_object_zh":"复合板"},{"_id":"6a5a55f19af9f73f38250f3c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty kompozytowe","test_object_en":"Composite panels","methodology":"Odporność na uderzenie ciałem miękkim i ciałem twardym Metoda udarowa","methodology_en":"Soft body and hard body impact resistance Impact method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie ciałem miękkim i ciałem twardym Metoda udarowa","reference":"ETAG 016:2004 cz. 2 ETAG 016:2004 cz. 3 TR001","norm_bases":["ETAG 016:2004 cz. 2 ETAG 016:2004 cz. 3 TR001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty kompozytowe Odporność na uderzenie ciałem miękkim i ciałem twardym Metoda udarowa ETAG 016:2004 cz. 2 ETAG 016:2004 cz. 3 TR001 Plyty kompozytowe Odpornosc na uderzenie cialem miekkim i cialem twardym Metoda udarowa ETAG 016:2004 cz. 2 ETAG 016:2004 cz. 3 TR001","categories":["materials"],"row_index":40,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Composite panels Soft body and hard body impact resistance Impact method ETAG 016:2004 cz. 2 ETAG 016:2004 cz. 3 TR001","search_zh":"复合板 ETAG 016:2004 cz. 2 ETAG 016:2004 cz. 3 TR001","test_object_zh":"复合板"},{"_id":"6a5a55f19af9f73f38250f3d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty kompozytowe","test_object_en":"Composite panels","methodology":"Pełzanie","methodology_en":"Creep","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pełzanie","reference":"ETAG 016:2004 cz. 2","norm_bases":["ETAG 016:2004 cz. 2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty kompozytowe Pełzanie ETAG 016:2004 cz. 2 Plyty kompozytowe Pelzanie ETAG 016:2004 cz. 2","categories":["materials"],"row_index":41,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Composite panels Creep ETAG 016:2004 cz. 2","search_zh":"复合板 ETAG 016:2004 cz. 2","test_object_zh":"复合板"},{"_id":"6a5a55f19af9f73f38250f3e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty kompozytowe","test_object_en":"Composite panels","methodology":"Trwałość – cykle badań klimatycznych Temp. do 80ºC, powierzchnia do (3x4) m","methodology_en":"Durability – climatic test cycles Temp. up to 80ºC, area up to (3x4) m","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość – cykle badań klimatycznych Temp. do 80ºC, powierzchnia do (3x4) m","reference":"ETAG 016:2004 cz. 2 ETAG 016:2004 cz. 3","norm_bases":["ETAG 016:2004 cz. 2 ETAG 016:2004 cz. 3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty kompozytowe Trwałość – cykle badań klimatycznych Temp. do 80ºC, powierzchnia do (3x4) m ETAG 016:2004 cz. 2 ETAG 016:2004 cz. 3 Plyty kompozytowe Trwalosc – cykle badan klimatycznych Temp. do 80ºC, powierzchnia do (3x4) m ETAG 016:2004 cz. 2 ETAG 016:2004 cz. 3","categories":["materials"],"row_index":42,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Composite panels Durability – climatic test cycles Temp. up to 80ºC, area up to (3x4) m ETAG 016:2004 cz. 2 ETAG 016:2004 cz. 3","search_zh":"复合板 ETAG 016:2004 cz. 2 ETAG 016:2004 cz. 3","test_object_zh":"复合板"},{"_id":"6a5a55f19af9f73f38250f3f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty kompozytowe","test_object_en":"Composite panels","methodology":"Wytrzymałość płyt w miejscach zamocowań na złączach (nośność i stateczność łączników)","methodology_en":"Strength of the boards at the fixing points on the joints (load capacity and stability of the fasteners)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość płyt w miejscach zamocowań na złączach (nośność i stateczność łączników)","reference":"ETAG 016:2004 cz. 1","norm_bases":["ETAG 016:2004 cz. 1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty kompozytowe Wytrzymałość płyt w miejscach zamocowań na złączach (nośność i stateczność łączników) ETAG 016:2004 cz. 1 Plyty kompozytowe Wytrzymalosc plyt w miejscach zamocowan na zlaczach (nosnosc i statecznosc lacznikow) ETAG 016:2004 cz. 1","categories":["materials"],"row_index":43,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Composite panels Strength of the boards at the fixing points on the joints (load capacity and stability of the fasteners) ETAG 016:2004 cz. 1","search_zh":"复合板 ETAG 016:2004 cz. 1","test_object_zh":"复合板"},{"_id":"6a5a55f19af9f73f38250f40","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty kompozytowe","test_object_en":"Composite panels","methodology":"Wytrzymałość na obciążenie mimośrodowe spowodowane przedmiotami mocowanymi do płyty","methodology_en":"Resistance to eccentric load caused by objects fixed to the board","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na obciążenie mimośrodowe spowodowane przedmiotami mocowanymi do płyty","reference":"ETAG 016:2004 cz. 2 ETAG 016:2004 cz. 3","norm_bases":["ETAG 016:2004 cz. 2 ETAG 016:2004 cz. 3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty kompozytowe Wytrzymałość na obciążenie mimośrodowe spowodowane przedmiotami mocowanymi do płyty ETAG 016:2004 cz. 2 ETAG 016:2004 cz. 3 Plyty kompozytowe Wytrzymalosc na obciazenie mimosrodowe spowodowane przedmiotami mocowanymi do plyty ETAG 016:2004 cz. 2 ETAG 016:2004 cz. 3","categories":["materials"],"row_index":44,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Composite panels Resistance to eccentric load caused by objects fixed to the board ETAG 016:2004 cz. 2 ETAG 016:2004 cz. 3","search_zh":"复合板 ETAG 016:2004 cz. 2 ETAG 016:2004 cz. 3","test_object_zh":"复合板"},{"_id":"6a5a55f19af9f73f38250f41","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty kompozytowe","test_object_en":"Composite panels","methodology":"Wytrzymałość zamocowań do płyty","methodology_en":"Strength of the fixings to the board","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość zamocowań do płyty","reference":"ETAG 016:2004 cz. 3","norm_bases":["ETAG 016:2004 cz. 3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty kompozytowe Wytrzymałość zamocowań do płyty ETAG 016:2004 cz. 3 Plyty kompozytowe Wytrzymalosc zamocowan do plyty ETAG 016:2004 cz. 3","categories":["materials"],"row_index":45,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Composite panels Strength of the fixings to the board ETAG 016:2004 cz. 3","search_zh":"复合板 ETAG 016:2004 cz. 3","test_object_zh":"复合板"},{"_id":"6a5a55f19af9f73f38250f42","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty kompozytowe","test_object_en":"Composite panels","methodology":"Zdolność do przeniesienia (doraźnego) okresowego ruchu pieszego Metoda obciążenia punktowego","methodology_en":"Ability to carry (temporary) periodic pedestrian traffic Point load method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność do przeniesienia (doraźnego) okresowego ruchu pieszego Metoda obciążenia punktowego","reference":"ETAG 016:2004 cz. 2","norm_bases":["ETAG 016:2004 cz. 2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty kompozytowe Zdolność do przeniesienia (doraźnego) okresowego ruchu pieszego Metoda obciążenia punktowego ETAG 016:2004 cz. 2 Plyty kompozytowe Zdolnosc do przeniesienia (doraznego) okresowego ruchu pieszego Metoda obciazenia punktowego ETAG 016:2004 cz. 2","categories":["materials"],"row_index":46,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Composite panels Ability to carry (temporary) periodic pedestrian traffic Point load method ETAG 016:2004 cz. 2","search_zh":"复合板 ETAG 016:2004 cz. 2","test_object_zh":"复合板"},{"_id":"6a5a55f19af9f73f38250f43","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Ściany działowe","test_object_en":"Partition walls","methodology":"Odporność na uderzenie ciałem twardym pkt E 3","methodology_en":"Hard body impact resistance clause E 3","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie ciałem twardym pkt E 3","reference":"EAD 210005-00-0505","norm_bases":["EAD 210005-00-0505"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ściany działowe Odporność na uderzenie ciałem twardym pkt E 3 EAD 210005-00-0505 Sciany dzialowe Odpornosc na uderzenie cialem twardym pkt E 3 EAD 210005-00-0505","categories":["other"],"row_index":47,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Partition walls Hard body impact resistance clause E 3 EAD 210005-00-0505","search_zh":"隔墙 EAD 210005-00-0505","test_object_zh":"隔墙"},{"_id":"6a5a55f19af9f73f38250f44","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Świetliki dachowe","test_object_en":"Roof lights","methodology":"Przepuszczalność","methodology_en":"Permeability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność","reference":"PN-EN 1873:2009 „N” PN-EN 1873+A1:2016-03","norm_bases":["PN-EN 1873:2009 „N” PN-EN 1873+A1:2016-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Świetliki dachowe Przepuszczalność PN-EN 1873:2009 „N” PN-EN 1873+A1:2016-03 Swietliki dachowe Przepuszczalnosc PN-EN 1873:2009 „N” PN-EN 1873+A1:2016-03","categories":["construction"],"row_index":48,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Roof lights Permeability PN-EN 1873:2009 „N” PN-EN 1873+A1:2016-03"},{"_id":"6a5a55f19af9f73f38250f45","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Świetliki: - pasmowe, - punktowe, - inne","test_object_en":"Rooflights: - continuous, - point, - other","methodology":"Przepuszczalność powietrza przy określonej różnicy ciśnień +","methodology_en":"Air permeability at a specified pressure difference +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność powietrza przy określonej różnicy ciśnień +","reference":"ASTM E283/E283M-19","norm_bases":["ASTM E283/E283M-19"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Świetliki: - pasmowe, - punktowe, - inne Przepuszczalność powietrza przy określonej różnicy ciśnień + ASTM E283/E283M-19 Swietliki: - pasmowe, - punktowe, - inne Przepuszczalnosc powietrza przy okreslonej roznicy cisnien + ASTM E283/E283M-19","categories":["other"],"row_index":49,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooflights: - continuous, - point, - other Air permeability at a specified pressure difference + ASTM E283/E283M-19","search_zh":"采光天窗：－ 带形，－ 点式，－ 其他 规定压差下的透气性 + ASTM E283/E283M-19","test_object_zh":"采光天窗：－ 带形，－ 点式，－ 其他","methodology_zh":"规定压差下的透气性 +"},{"_id":"6a5a55f19af9f73f38250f46","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Świetliki: - pasmowe, - punktowe, - inne","test_object_en":"Rooflights: - continuous, - point, - other","methodology":"Siły operacyjne +","methodology_en":"Operating forces +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siły operacyjne +","reference":"AAMA/WDMA/CSA 101/I.S.2/A440:22 ASTM E2068-00(2022)","norm_bases":["AAMA/WDMA/CSA 101/I.S.2/A440:22 ASTM E2068-00(2022)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Świetliki: - pasmowe, - punktowe, - inne Siły operacyjne + AAMA/WDMA/CSA 101/I.S.2/A440:22 ASTM E2068-00(2022) Swietliki: - pasmowe, - punktowe, - inne Sily operacyjne + AAMA/WDMA/CSA 101/I.S.2/A440:22 ASTM E2068-00(2022)","categories":["other"],"row_index":50,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooflights: - continuous, - point, - other Operating forces + AAMA/WDMA/CSA 101/I.S.2/A440:22 ASTM E2068-00(2022)","search_zh":"采光天窗：－ 带形，－ 点式，－ 其他 操作力 + AAMA/WDMA/CSA 101/I.S.2/A440:22 ASTM E2068-00(2022)","test_object_zh":"采光天窗：－ 带形，－ 点式，－ 其他","methodology_zh":"操作力 +"},{"_id":"6a5a55f19af9f73f38250f47","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Świetliki: - pasmowe, - punktowe, - inne","test_object_en":"Rooflights: - continuous, - point, - other","methodology":"Sztywność i wytrzymałość przy obciążeniu ciśnieniem statycznym +","methodology_en":"Stiffness and strength under static pressure loading +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sztywność i wytrzymałość przy obciążeniu ciśnieniem statycznym +","reference":"ASTM E330/E330M-14(2021)","norm_bases":["ASTM E330/E330M-14(2021)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Świetliki: - pasmowe, - punktowe, - inne Sztywność i wytrzymałość przy obciążeniu ciśnieniem statycznym + ASTM E330/E330M-14(2021) Swietliki: - pasmowe, - punktowe, - inne Sztywnosc i wytrzymalosc przy obciazeniu cisnieniem statycznym + ASTM E330/E330M-14(2021)","categories":["other"],"row_index":51,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooflights: - continuous, - point, - other Stiffness and strength under static pressure loading + ASTM E330/E330M-14(2021)","search_zh":"采光天窗：－ 带形，－ 点式，－ 其他 静压荷载下的刚度与强度 + ASTM E330/E330M-14(2021)","test_object_zh":"采光天窗：－ 带形，－ 点式，－ 其他","methodology_zh":"静压荷载下的刚度与强度 +"},{"_id":"6a5a55f19af9f73f38250f48","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Świetliki: - pasmowe, - punktowe, - inne","test_object_en":"Rooflights: - continuous, - point, - other","methodology":"Wodoszczelność przy cyklicznej statycznej różnicy ciśnień +","methodology_en":"Watertightness under cyclic static pressure difference +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność przy cyklicznej statycznej różnicy ciśnień +","reference":"ASTM E547-00(2016)","norm_bases":["ASTM E547-00(2016)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Świetliki: - pasmowe, - punktowe, - inne Wodoszczelność przy cyklicznej statycznej różnicy ciśnień + ASTM E547-00(2016) Swietliki: - pasmowe, - punktowe, - inne Wodoszczelnosc przy cyklicznej statycznej roznicy cisnien + ASTM E547-00(2016)","categories":["other"],"row_index":52,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooflights: - continuous, - point, - other Watertightness under cyclic static pressure difference + ASTM E547-00(2016)","search_zh":"采光天窗：－ 带形，－ 点式，－ 其他 循环静压差下的水密性 + ASTM E547-00(2016)","test_object_zh":"采光天窗：－ 带形，－ 点式，－ 其他","methodology_zh":"循环静压差下的水密性 +"},{"_id":"6a5a55f19af9f73f38250f49","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Świetliki: - pasmowe, - punktowe, - inne","test_object_en":"Rooflights: - continuous, - point, - other","methodology":"Wodoszczelność przy statycznej różnicy ciśnień +","methodology_en":"Watertightness under static pressure difference +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność przy statycznej różnicy ciśnień +","reference":"ASTM E331-00(2023)","norm_bases":["ASTM E331-00(2023)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Świetliki: - pasmowe, - punktowe, - inne Wodoszczelność przy statycznej różnicy ciśnień + ASTM E331-00(2023) Swietliki: - pasmowe, - punktowe, - inne Wodoszczelnosc przy statycznej roznicy cisnien + ASTM E331-00(2023)","categories":["other"],"row_index":53,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooflights: - continuous, - point, - other Watertightness under static pressure difference + ASTM E331-00(2023)","search_zh":"采光天窗：－ 带形，－ 点式，－ 其他 静压差下的水密性 + ASTM E331-00(2023)","test_object_zh":"采光天窗：－ 带形，－ 点式，－ 其他","methodology_zh":"静压差下的水密性 +"},{"_id":"6a5a55f19af9f73f38250f4a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zestawy okładzin wentylowanych i typu VETURE","test_object_en":"Ventilated cladding kits and VETURE kits","methodology":"Odporność na działanie siły poziomej elementów rusztu","methodology_en":"Resistance of grid components to horizontal force","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie siły poziomej elementów rusztu","reference":"EAD 090062-00-0404","norm_bases":["EAD 090062-00-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zestawy okładzin wentylowanych i typu VETURE Odporność na działanie siły poziomej elementów rusztu EAD 090062-00-0404 Zestawy okladzin wentylowanych i typu VETURE Odpornosc na dzialanie sily poziomej elementow rusztu EAD 090062-00-0404","categories":["other"],"row_index":54,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ventilated cladding kits and VETURE kits Resistance of grid components to horizontal force EAD 090062-00-0404","search_zh":"通风幕墙饰面系统与 VETURE 型系统 EAD 090062-00-0404","test_object_zh":"通风幕墙饰面系统与 VETURE 型系统"},{"_id":"6a5a55f19af9f73f38250f4b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zestawy okładzin wentylowanych i typu VETURE","test_object_en":"Ventilated cladding kits and VETURE kits","methodology":"Odporność na działanie siły pionowej elementów rusztu","methodology_en":"Resistance of grid components to vertical force","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie siły pionowej elementów rusztu","reference":"EAD 090062-00-0404","norm_bases":["EAD 090062-00-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zestawy okładzin wentylowanych i typu VETURE Odporność na działanie siły pionowej elementów rusztu EAD 090062-00-0404 Zestawy okladzin wentylowanych i typu VETURE Odpornosc na dzialanie sily pionowej elementow rusztu EAD 090062-00-0404","categories":["other"],"row_index":55,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ventilated cladding kits and VETURE kits Resistance of grid components to vertical force EAD 090062-00-0404","search_zh":"通风幕墙饰面系统与 VETURE 型系统 EAD 090062-00-0404","test_object_zh":"通风幕墙饰面系统与 VETURE 型系统"},{"_id":"6a5a55f19af9f73f38250f4c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zestawy okładzin wentylowanych i typu VETURE","test_object_en":"Ventilated cladding kits and VETURE kits","methodology":"Wytrzymałość na przeciąganie Zakres: dla rodziny wyrobów A, B i D","methodology_en":"Pull-through strength Range: for product families A, B and D","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na przeciąganie Zakres: dla rodziny wyrobów A, B i D","reference":"EAD 090062-00-0404","norm_bases":["EAD 090062-00-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zestawy okładzin wentylowanych i typu VETURE Wytrzymałość na przeciąganie Zakres: dla rodziny wyrobów A, B i D EAD 090062-00-0404 Zestawy okladzin wentylowanych i typu VETURE Wytrzymalosc na przeciaganie Zakres: dla rodziny wyrobow A, B i D EAD 090062-00-0404","categories":["other"],"row_index":56,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ventilated cladding kits and VETURE kits Pull-through strength Range: for product families A, B and D EAD 090062-00-0404","search_zh":"通风幕墙饰面系统与 VETURE 型系统 EAD 090062-00-0404","test_object_zh":"通风幕墙饰面系统与 VETURE 型系统"},{"_id":"6a5a55f19af9f73f38250f4d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zestawy okładzin wentylowanych i typu VETURE","test_object_en":"Ventilated cladding kits and VETURE kits","methodology":"Odporność na działanie wiatru Metoda różnicy ciśnień","methodology_en":"Resistance to wind Pressure difference method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie wiatru Metoda różnicy ciśnień","reference":"EAD 090034-00-0404","norm_bases":["EAD 090034-00-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zestawy okładzin wentylowanych i typu VETURE Odporność na działanie wiatru Metoda różnicy ciśnień EAD 090034-00-0404 Zestawy okladzin wentylowanych i typu VETURE Odpornosc na dzialanie wiatru Metoda roznicy cisnien EAD 090034-00-0404","categories":["other"],"row_index":57,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ventilated cladding kits and VETURE kits Resistance to wind Pressure difference method EAD 090034-00-0404","search_zh":"通风幕墙饰面系统与 VETURE 型系统 EAD 090034-00-0404","test_object_zh":"通风幕墙饰面系统与 VETURE 型系统"},{"_id":"6a5a55f19af9f73f38250f4e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zestawy okładzin wentylowanych i typu VETURE","test_object_en":"Ventilated cladding kits and VETURE kits","methodology":"Odporność na obciążenie siłą pionową całego zestawu","methodology_en":"Resistance to vertical force load of the complete set","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenie siłą pionową całego zestawu","reference":"EAD 090034-00-0404","norm_bases":["EAD 090034-00-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zestawy okładzin wentylowanych i typu VETURE Odporność na obciążenie siłą pionową całego zestawu EAD 090034-00-0404 Zestawy okladzin wentylowanych i typu VETURE Odpornosc na obciazenie sila pionowa calego zestawu EAD 090034-00-0404","categories":["other"],"row_index":58,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ventilated cladding kits and VETURE kits Resistance to vertical force load of the complete set EAD 090034-00-0404","search_zh":"通风幕墙饰面系统与 VETURE 型系统 EAD 090034-00-0404","test_object_zh":"通风幕墙饰面系统与 VETURE 型系统"},{"_id":"6a5a55f19af9f73f38250f4f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zestawy okładzin wentylowanych i typu VETURE","test_object_en":"Ventilated cladding kits and VETURE kits","methodology":"Odporność na działanie siły pionowej konsoli Metoda wytrzymałościowa","methodology_en":"Resistance of the bracket to vertical force Strength method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie siły pionowej konsoli Metoda wytrzymałościowa","reference":"EAD 090034-00-0404","norm_bases":["EAD 090034-00-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zestawy okładzin wentylowanych i typu VETURE Odporność na działanie siły pionowej konsoli Metoda wytrzymałościowa EAD 090034-00-0404 Zestawy okladzin wentylowanych i typu VETURE Odpornosc na dzialanie sily pionowej konsoli Metoda wytrzymalosciowa EAD 090034-00-0404","categories":["other"],"row_index":59,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ventilated cladding kits and VETURE kits Resistance of the bracket to vertical force Strength method EAD 090034-00-0404","search_zh":"通风幕墙饰面系统与 VETURE 型系统 EAD 090034-00-0404","test_object_zh":"通风幕墙饰面系统与 VETURE 型系统"},{"_id":"6a5a55f19af9f73f38250f50","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zestawy okładzin wentylowanych i typu VETURE","test_object_en":"Ventilated cladding kits and VETURE kits","methodology":"Odporność na działanie siły poziomej konsoli Metoda wytrzymałościowa","methodology_en":"Resistance of the bracket to horizontal force Strength method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie siły poziomej konsoli Metoda wytrzymałościowa","reference":"EAD 090034-00-0404","norm_bases":["EAD 090034-00-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zestawy okładzin wentylowanych i typu VETURE Odporność na działanie siły poziomej konsoli Metoda wytrzymałościowa EAD 090034-00-0404 Zestawy okladzin wentylowanych i typu VETURE Odpornosc na dzialanie sily poziomej konsoli Metoda wytrzymalosciowa EAD 090034-00-0404","categories":["other"],"row_index":60,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ventilated cladding kits and VETURE kits Resistance of the bracket to horizontal force Strength method EAD 090034-00-0404","search_zh":"通风幕墙饰面系统与 VETURE 型系统 EAD 090034-00-0404","test_object_zh":"通风幕墙饰面系统与 VETURE 型系统"},{"_id":"6a5a55f19af9f73f38250f51","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu","test_object_en":"Windows including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated","methodology":"Przepuszczalność powietrza przy określonej różnicy ciśnień +","methodology_en":"Air permeability at a specified pressure difference +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność powietrza przy określonej różnicy ciśnień +","reference":"ASTM E283/E283M-19","norm_bases":["ASTM E283/E283M-19"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu Przepuszczalność powietrza przy określonej różnicy ciśnień + ASTM E283/E283M-19 Okna w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane recznie lub za pomoca napedu Przepuszczalnosc powietrza przy okreslonej roznicy cisnien + ASTM E283/E283M-19","categories":["construction"],"row_index":61,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated Air permeability at a specified pressure difference + ASTM E283/E283M-19","search_zh":"窗，其中包括：－ 阳台门，－ 屋面窗，－ 门窗组合，－ 类似结构，－ 手动或带驱动装置操作 规定压差下的透气性 + ASTM E283/E283M-19","test_object_zh":"窗，其中包括：－ 阳台门，－ 屋面窗，－ 门窗组合，－ 类似结构，－ 手动或带驱动装置操作","methodology_zh":"规定压差下的透气性 +"},{"_id":"6a5a55f19af9f73f38250f52","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu","test_object_en":"Windows including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated","methodology":"Siły operacyjne +","methodology_en":"Operating forces +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siły operacyjne +","reference":"AAMA/WDMA/CSA 101/I.S.2/A440:22 ASTM E2068-00(2022)","norm_bases":["AAMA/WDMA/CSA 101/I.S.2/A440:22 ASTM E2068-00(2022)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu Siły operacyjne + AAMA/WDMA/CSA 101/I.S.2/A440:22 ASTM E2068-00(2022) Okna w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane recznie lub za pomoca napedu Sily operacyjne + AAMA/WDMA/CSA 101/I.S.2/A440:22 ASTM E2068-00(2022)","categories":["construction"],"row_index":62,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated Operating forces + AAMA/WDMA/CSA 101/I.S.2/A440:22 ASTM E2068-00(2022)","search_zh":"窗，其中包括：－ 阳台门，－ 屋面窗，－ 门窗组合，－ 类似结构，－ 手动或带驱动装置操作 操作力 + AAMA/WDMA/CSA 101/I.S.2/A440:22 ASTM E2068-00(2022)","test_object_zh":"窗，其中包括：－ 阳台门，－ 屋面窗，－ 门窗组合，－ 类似结构，－ 手动或带驱动装置操作","methodology_zh":"操作力 +"},{"_id":"6a5a55f19af9f73f38250f53","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu","test_object_en":"Windows including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated","methodology":"Sztywność i wytrzymałość przy obciążeniu ciśnieniem statycznym +","methodology_en":"Stiffness and strength under static pressure loading +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sztywność i wytrzymałość przy obciążeniu ciśnieniem statycznym +","reference":"ASTM E330/E330M-14(2021)","norm_bases":["ASTM E330/E330M-14(2021)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu Sztywność i wytrzymałość przy obciążeniu ciśnieniem statycznym + ASTM E330/E330M-14(2021) Okna w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane recznie lub za pomoca napedu Sztywnosc i wytrzymalosc przy obciazeniu cisnieniem statycznym + ASTM E330/E330M-14(2021)","categories":["construction"],"row_index":63,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated Stiffness and strength under static pressure loading + ASTM E330/E330M-14(2021)","search_zh":"窗，其中包括：－ 阳台门，－ 屋面窗，－ 门窗组合，－ 类似结构，－ 手动或带驱动装置操作 静压荷载下的刚度与强度 + ASTM E330/E330M-14(2021)","test_object_zh":"窗，其中包括：－ 阳台门，－ 屋面窗，－ 门窗组合，－ 类似结构，－ 手动或带驱动装置操作","methodology_zh":"静压荷载下的刚度与强度 +"},{"_id":"6a5a55f19af9f73f38250f54","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu","test_object_en":"Windows including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated","methodology":"Wodoszczelność przy cyklicznej statycznej różnicy ciśnień +","methodology_en":"Watertightness under cyclic static pressure difference +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność przy cyklicznej statycznej różnicy ciśnień +","reference":"ASTM E547-00(2016)","norm_bases":["ASTM E547-00(2016)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu Wodoszczelność przy cyklicznej statycznej różnicy ciśnień + ASTM E547-00(2016) Okna w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane recznie lub za pomoca napedu Wodoszczelnosc przy cyklicznej statycznej roznicy cisnien + ASTM E547-00(2016)","categories":["construction"],"row_index":64,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated Watertightness under cyclic static pressure difference + ASTM E547-00(2016)","search_zh":"窗，其中包括：－ 阳台门，－ 屋面窗，－ 门窗组合，－ 类似结构，－ 手动或带驱动装置操作 循环静压差下的水密性 + ASTM E547-00(2016)","test_object_zh":"窗，其中包括：－ 阳台门，－ 屋面窗，－ 门窗组合，－ 类似结构，－ 手动或带驱动装置操作","methodology_zh":"循环静压差下的水密性 +"},{"_id":"6a5a55f19af9f73f38250f55","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu","test_object_en":"Windows including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated","methodology":"Wodoszczelność przy statycznej różnicy ciśnień +","methodology_en":"Watertightness under static pressure difference +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność przy statycznej różnicy ciśnień +","reference":"ASTM E331-00(2023)","norm_bases":["ASTM E331-00(2023)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu Wodoszczelność przy statycznej różnicy ciśnień + ASTM E331-00(2023) Okna w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane recznie lub za pomoca napedu Wodoszczelnosc przy statycznej roznicy cisnien + ASTM E331-00(2023)","categories":["construction"],"row_index":65,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated Watertightness under static pressure difference + ASTM E331-00(2023)","search_zh":"窗，其中包括：－ 阳台门，－ 屋面窗，－ 门窗组合，－ 类似结构，－ 手动或带驱动装置操作 静压差下的水密性 + ASTM E331-00(2023)","test_object_zh":"窗，其中包括：－ 阳台门，－ 屋面窗，－ 门窗组合，－ 类似结构，－ 手动或带驱动装置操作","methodology_zh":"静压差下的水密性 +"},{"_id":"6a5a55f19af9f73f38250f56","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Witryny","test_object_en":"Shopfronts","methodology":"Przepuszczalność powietrza przy określonej różnicy ciśnień +","methodology_en":"Air permeability at a specified pressure difference +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność powietrza przy określonej różnicy ciśnień +","reference":"ASTM E283/E283M-19","norm_bases":["ASTM E283/E283M-19"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Witryny Przepuszczalność powietrza przy określonej różnicy ciśnień + ASTM E283/E283M-19 Witryny Przepuszczalnosc powietrza przy okreslonej roznicy cisnien + ASTM E283/E283M-19","categories":["other"],"row_index":66,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Shopfronts Air permeability at a specified pressure difference + ASTM E283/E283M-19","methodology_zh":"规定压差下的透气性 +","search_zh":"展示橱窗 规定压差下的透气性 + ASTM E283/E283M-19","test_object_zh":"展示橱窗"},{"_id":"6a5a55f19af9f73f38250f57","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Witryny","test_object_en":"Shopfronts","methodology":"Sztywność i wytrzymałość przy obciążeniu ciśnieniem statycznym +","methodology_en":"Stiffness and strength under static pressure loading +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sztywność i wytrzymałość przy obciążeniu ciśnieniem statycznym +","reference":"ASTM E330/E330M-14(2021)","norm_bases":["ASTM E330/E330M-14(2021)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Witryny Sztywność i wytrzymałość przy obciążeniu ciśnieniem statycznym + ASTM E330/E330M-14(2021) Witryny Sztywnosc i wytrzymalosc przy obciazeniu cisnieniem statycznym + ASTM E330/E330M-14(2021)","categories":["other"],"row_index":67,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Shopfronts Stiffness and strength under static pressure loading + ASTM E330/E330M-14(2021)","methodology_zh":"静压荷载下的刚度与强度 +","search_zh":"展示橱窗 静压荷载下的刚度与强度 + ASTM E330/E330M-14(2021)","test_object_zh":"展示橱窗"},{"_id":"6a5a55f19af9f73f38250f58","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Witryny","test_object_en":"Shopfronts","methodology":"Wodoszczelność przy cyklicznej statycznej różnicy ciśnień +","methodology_en":"Watertightness under cyclic static pressure difference +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność przy cyklicznej statycznej różnicy ciśnień +","reference":"ASTM E547-00(2016)","norm_bases":["ASTM E547-00(2016)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Witryny Wodoszczelność przy cyklicznej statycznej różnicy ciśnień + ASTM E547-00(2016) Witryny Wodoszczelnosc przy cyklicznej statycznej roznicy cisnien + ASTM E547-00(2016)","categories":["other"],"row_index":68,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Shopfronts Watertightness under cyclic static pressure difference + ASTM E547-00(2016)","methodology_zh":"循环静压差下的水密性 +","search_zh":"展示橱窗 循环静压差下的水密性 + ASTM E547-00(2016)","test_object_zh":"展示橱窗"},{"_id":"6a5a55f19af9f73f38250f59","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Witryny","test_object_en":"Shopfronts","methodology":"Wodoszczelność przy statycznej różnicy ciśnień +","methodology_en":"Watertightness under static pressure difference +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność przy statycznej różnicy ciśnień +","reference":"ASTM E331-00(2023)","norm_bases":["ASTM E331-00(2023)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Witryny Wodoszczelność przy statycznej różnicy ciśnień + ASTM E331-00(2023) Witryny Wodoszczelnosc przy statycznej roznicy cisnien + ASTM E331-00(2023)","categories":["other"],"row_index":69,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Shopfronts Watertightness under static pressure difference + ASTM E331-00(2023)","methodology_zh":"静压差下的水密性 +","search_zh":"展示橱窗 静压差下的水密性 + ASTM E331-00(2023)","test_object_zh":"展示橱窗"},{"_id":"6a5a55f19af9f73f38250f5a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Bramy E","test_object_en":"Gates E","methodology":"Bezpieczeństwo użytkowania bram z napędem +","methodology_en":"Safety in use of power-operated doors +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Bezpieczeństwo użytkowania bram z napędem +","reference":"PN-EN 12445 “N” PN-EN 12453 “N”","norm_bases":["PN-EN 12445 “N” PN-EN 12453 “N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bramy E Bezpieczeństwo użytkowania bram z napędem + PN-EN 12445 “N” PN-EN 12453 “N” Bramy E Bezpieczenstwo uzytkowania bram z napedem + PN-EN 12445 “N” PN-EN 12453 “N”","categories":["other"],"row_index":70,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gates E Safety in use of power-operated doors + PN-EN 12445 “N” PN-EN 12453 “N”","search_zh":"大门 E PN-EN 12445 “N” PN-EN 12453 “N”","test_object_zh":"大门 E"},{"_id":"6a5a55f19af9f73f38250f5b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Bramy E","test_object_en":"Gates E","methodology":"Siły na krawędziach +","methodology_en":"Forces at the edges +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siły na krawędziach +","reference":"PN-EN 12453 “N”","norm_bases":["PN-EN 12453 “N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bramy E Siły na krawędziach + PN-EN 12453 “N” Bramy E Sily na krawedziach + PN-EN 12453 “N”","categories":["other"],"row_index":71,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gates E Forces at the edges + PN-EN 12453 “N”","search_zh":"大门 E PN-EN 12453 “N”","test_object_zh":"大门 E"},{"_id":"6a5a55f19af9f73f38250f5c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Bramy E","test_object_en":"Gates E","methodology":"Funkcjonalność +","methodology_en":"Functionality +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Funkcjonalność +","reference":"PN-EN 12605 “N” PN-EN 12604 “N”","norm_bases":["PN-EN 12605 “N” PN-EN 12604 “N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bramy E Funkcjonalność + PN-EN 12605 “N” PN-EN 12604 “N” Bramy E Funkcjonalnosc + PN-EN 12605 “N” PN-EN 12604 “N”","categories":["other"],"row_index":72,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gates E Functionality + PN-EN 12605 “N” PN-EN 12604 “N”","search_zh":"大门 E 功能性 + PN-EN 12605 “N” PN-EN 12604 “N”","test_object_zh":"大门 E","methodology_zh":"功能性 +"},{"_id":"6a5a55f19af9f73f38250f5d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Bramy E","test_object_en":"Gates E","methodology":"Trwałość +","methodology_en":"Durability +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość +","reference":"PN-EN 12605 “N” PN-EN 12604 “N”","norm_bases":["PN-EN 12605 “N” PN-EN 12604 “N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bramy E Trwałość + PN-EN 12605 “N” PN-EN 12604 “N” Bramy E Trwalosc + PN-EN 12605 “N” PN-EN 12604 “N”","categories":["other"],"row_index":73,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gates E Durability + PN-EN 12605 “N” PN-EN 12604 “N”","search_zh":"大门 E 耐久性 + PN-EN 12605 “N” PN-EN 12604 “N”","test_object_zh":"大门 E","methodology_zh":"耐久性 +"},{"_id":"6a5a55f19af9f73f38250f5e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Bramy E","test_object_en":"Gates E","methodology":"Wykonanie +","methodology_en":"Workmanship +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wykonanie +","reference":"PN-EN 12605 “N” PN-EN 12604 “N”","norm_bases":["PN-EN 12605 “N” PN-EN 12604 “N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bramy E Wykonanie + PN-EN 12605 “N” PN-EN 12604 “N” Bramy E Wykonanie + PN-EN 12605 “N” PN-EN 12604 “N”","categories":["other"],"row_index":74,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gates E Workmanship + PN-EN 12605 “N” PN-EN 12604 “N”","search_zh":"大门 E 制作工艺 + PN-EN 12605 “N” PN-EN 12604 “N”","test_object_zh":"大门 E","methodology_zh":"制作工艺 +"},{"_id":"6a5a55f19af9f73f38250f5f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Bramy E","test_object_en":"Gates E","methodology":"Bezpieczeństwo użytkowania bram z napędem: - Zagrożenie zgnieceniem, ścinaniem i wciągnięciem; - Siły otwierające i zamykające; - Wykrywanie obecności; - Zagrożenie zgnieceniem i ścinaniem spowodowane możliwością przemieszczenia się człowieka wraz z bramą; - Zagrożenie uderzeniem; - Obsługa ręczna; - Sprawdzenie bezpieczeństwa wynikającego z innych zagrożeń +","methodology_en":"Safety in use of power operated doors: - Risk of crushing, shearing and drawing-in; - Opening and closing forces; - Presence detection; - Risk of crushing and shearing caused by the possibility of a person being moved together with the door; - Risk of impact; - Manual operation; - Verification of safety with respect to other hazards +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Bezpieczeństwo użytkowania bram z napędem: - Zagrożenie zgnieceniem, ścinaniem i wciągnięciem; - Siły otwierające i zamykające; - Wykrywanie obecności; - Zagrożenie zgnieceniem i ścinaniem spowodowane możliwością przemieszczenia się człowieka wraz z bramą; - Zagrożenie uderzeniem; - Obsługa ręczna; - Sprawdzenie bezpieczeństwa wynikającego z innych zagrożeń +","reference":"PN-EN 12453","norm_bases":["PN-EN 12453"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bramy E Bezpieczeństwo użytkowania bram z napędem: - Zagrożenie zgnieceniem, ścinaniem i wciągnięciem; - Siły otwierające i zamykające; - Wykrywanie obecności; - Zagrożenie zgnieceniem i ścinaniem spowodowane możliwością przemieszczenia się człowieka wraz z bramą; - Zagrożenie uderzeniem; - Obsługa ręczna; - Sprawdzenie bezpieczeństwa wynikającego z innych zagrożeń + PN-EN 12453 Bramy E Bezpieczenstwo uzytkowania bram z napedem: - Zagrozenie zgnieceniem, scinaniem i wciagnieciem; - Sily otwierajace i zamykajace; - Wykrywanie obecnosci; - Zagrozenie zgnieceniem i scinaniem spowodowane mozliwoscia przemieszczenia sie czlowieka wraz z brama; - Zagrozenie uderzeniem; - Obsluga reczna; - Sprawdzenie bezpieczenstwa wynikajacego z innych zagrozen + PN-EN 12453","categories":["other"],"row_index":75,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gates E Safety in use of power operated doors: - Risk of crushing, shearing and drawing-in; - Opening and closing forces; - Presence detection; - Risk of crushing and shearing caused by the possibility of a person being moved together with the door; - Risk of impact; - Manual operation; - Verification of safety with respect to other hazards + PN-EN 12453","search_zh":"大门 E PN-EN 12453","test_object_zh":"大门 E"},{"_id":"6a5a55f19af9f73f38250f60","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Bramy E","test_object_en":"Gates E","methodology":"Odporność na obciążenie wiatrem Zakres: ciśnienie (–5000 - +5000) Pa Metoda obciążenia równomiernego +","methodology_en":"Resistance to wind load Range: pressure (–5000 - +5000) Pa Uniform load method +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenie wiatrem Zakres: ciśnienie (–5000 - +5000) Pa Metoda obciążenia równomiernego +","reference":"PN-EN 12444 “N” PN-EN 12424 “N”","norm_bases":["PN-EN 12444 “N” PN-EN 12424 “N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bramy E Odporność na obciążenie wiatrem Zakres: ciśnienie (–5000 - +5000) Pa Metoda obciążenia równomiernego + PN-EN 12444 “N” PN-EN 12424 “N” Bramy E Odpornosc na obciazenie wiatrem Zakres: cisnienie (–5000 - +5000) Pa Metoda obciazenia rownomiernego + PN-EN 12444 “N” PN-EN 12424 “N”","categories":["other"],"row_index":76,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gates E Resistance to wind load Range: pressure (–5000 - +5000) Pa Uniform load method + PN-EN 12444 “N” PN-EN 12424 “N”","search_zh":"大门 E PN-EN 12444 “N” PN-EN 12424 “N”","test_object_zh":"大门 E"},{"_id":"6a5a55f19af9f73f38250f61","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Bramy E","test_object_en":"Gates E","methodology":"Odporność na przenikanie wody +","methodology_en":"Resistance to water penetration +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na przenikanie wody +","reference":"PN-EN 12489 “N” PN-EN 12425 “N”","norm_bases":["PN-EN 12489 “N” PN-EN 12425 “N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bramy E Odporność na przenikanie wody + PN-EN 12489 “N” PN-EN 12425 “N” Bramy E Odpornosc na przenikanie wody + PN-EN 12489 “N” PN-EN 12425 “N”","categories":["water"],"row_index":77,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gates E Resistance to water penetration + PN-EN 12489 “N” PN-EN 12425 “N”","search_zh":"大门 E 抗水渗透性 + PN-EN 12489 “N” PN-EN 12425 “N”","test_object_zh":"大门 E","methodology_zh":"抗水渗透性 +"},{"_id":"6a5a55f19af9f73f38250f62","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Bramy E","test_object_en":"Gates E","methodology":"Przepuszczalność powietrza +","methodology_en":"Air permeability +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność powietrza +","reference":"PN-EN 12427 “N” PN-EN 12426 “N”","norm_bases":["PN-EN 12427 “N” PN-EN 12426 “N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bramy E Przepuszczalność powietrza + PN-EN 12427 “N” PN-EN 12426 “N” Bramy E Przepuszczalnosc powietrza + PN-EN 12427 “N” PN-EN 12426 “N”","categories":["other"],"row_index":78,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gates E Air permeability + PN-EN 12427 “N” PN-EN 12426 “N”","search_zh":"大门 E 透气性 + PN-EN 12427 “N” PN-EN 12426 “N”","test_object_zh":"大门 E","methodology_zh":"透气性 +"},{"_id":"6a5a55f19af9f73f38250f63","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Bramy E","test_object_en":"Gates E","methodology":"Odporność na obciążenie wiatrem Metoda obliczeniowa","methodology_en":"Resistance to wind load Calculation method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenie wiatrem Metoda obliczeniowa","reference":"PN-EN 12444 „N”","norm_bases":["PN-EN 12444 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bramy E Odporność na obciążenie wiatrem Metoda obliczeniowa PN-EN 12444 „N” Bramy E Odpornosc na obciazenie wiatrem Metoda obliczeniowa PN-EN 12444 „N”","categories":["other"],"row_index":79,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gates E Resistance to wind load Calculation method PN-EN 12444 „N”","search_zh":"大门 E PN-EN 12444 „N”","test_object_zh":"大门 E"},{"_id":"6a5a55f19af9f73f38250f64","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Bramy E","test_object_en":"Gates E","methodology":"Samoczynne zamykanie","methodology_en":"Self-closing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Samoczynne zamykanie","reference":"PN-EN 16034","norm_bases":["PN-EN 16034"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bramy E Samoczynne zamykanie PN-EN 16034 Bramy E Samoczynne zamykanie PN-EN 16034","categories":["other"],"row_index":80,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gates E Self-closing PN-EN 16034","search_zh":"大门 E 自闭合 PN-EN 16034","test_object_zh":"大门 E","methodology_zh":"自闭合"},{"_id":"6a5a55f19af9f73f38250f65","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Bramy E","test_object_en":"Gates E","methodology":"Trwałość samoczynnego zamykania","methodology_en":"Durability of self-closing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość samoczynnego zamykania","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bramy E Trwałość samoczynnego zamykania Bramy E Trwalosc samoczynnego zamykania","categories":["other"],"row_index":81,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gates E Durability of self-closing","search_zh":"大门 E 自闭合耐久性","test_object_zh":"大门 E","methodology_zh":"自闭合耐久性"},{"_id":"6a5a55f19af9f73f38250f66","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Bramy E","test_object_en":"Gates E","methodology":"Aspekty mechaniczne: - Projekt i konstrukcja; - Ochrona przed niezamierzonym lub niekontrolowanym ruchem; - Siły do obsługi ręcznej; - Urządzenia do obsługi ręcznej – sprawdzenie/kontrola umiejscowienia i bezpieczeństwa konstrukcji uchwytów pod kątem zagrożenia zgnieceniem, pochwyceniem lub przecięciem ręki; - Ochrona palców; - Weryfikacja specjalnych wymagań dotyczących elementów stosowanych w systemach zawieszenia i równoważenia; - Drzwi przejściowe - sprawdzenie/ kontrole wzrokowe bezpiecznego położenia, zabezpieczenia przed mimowolnym ruchem oraz wymagań dotyczących progów; - Znaki i/lub urządzenia ostrzegawcze – sprawdzenie i kontrola wzrokowa możliwości rozpoznania miejsc niebezpiecznych i zagrożeń za pomocą znaków/ urządzeń ostrzegawczych +","methodology_en":"Mechanical aspects: - Design and construction; - Protection against unintended or uncontrolled movement; - Manual operating forces; - Manual operating devices – checking/inspection of the location and safe design of handles with regard to the risk of crushing, trapping or cutting of the hand; - Finger protection; - Verification of special requirements for components used in suspension and counterbalancing systems; - Pass doors - checking/ visual inspection of the safe position, protection against unintended movement and requirements for thresholds; - Warning signs and/or devices – checking and visual inspection of the possibility of identifying dangerous places and hazards by means of warning signs/ devices +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Aspekty mechaniczne: - Projekt i konstrukcja; - Ochrona przed niezamierzonym lub niekontrolowanym ruchem; - Siły do obsługi ręcznej; - Urządzenia do obsługi ręcznej – sprawdzenie/kontrola umiejscowienia i bezpieczeństwa konstrukcji uchwytów pod kątem zagrożenia zgnieceniem, pochwyceniem lub przecięciem ręki; - Ochrona palców; - Weryfikacja specjalnych wymagań dotyczących elementów stosowanych w systemach zawieszenia i równoważenia; - Drzwi przejściowe - sprawdzenie/ kontrole wzrokowe bezpiecznego położenia, zabezpieczenia przed mimowolnym ruchem oraz wymagań dotyczących progów; - Znaki i/lub urządzenia ostrzegawcze – sprawdzenie i kontrola wzrokowa możliwości rozpoznania miejsc niebezpiecznych i zagrożeń za pomocą znaków/ urządzeń ostrzegawczych +","reference":"PN-EN 12604","norm_bases":["PN-EN 12604"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bramy E Aspekty mechaniczne: - Projekt i konstrukcja; - Ochrona przed niezamierzonym lub niekontrolowanym ruchem; - Siły do obsługi ręcznej; - Urządzenia do obsługi ręcznej – sprawdzenie/kontrola umiejscowienia i bezpieczeństwa konstrukcji uchwytów pod kątem zagrożenia zgnieceniem, pochwyceniem lub przecięciem ręki; - Ochrona palców; - Weryfikacja specjalnych wymagań dotyczących elementów stosowanych w systemach zawieszenia i równoważenia; - Drzwi przejściowe - sprawdzenie/ kontrole wzrokowe bezpiecznego położenia, zabezpieczenia przed mimowolnym ruchem oraz wymagań dotyczących progów; - Znaki i/lub urządzenia ostrzegawcze – sprawdzenie i kontrola wzrokowa możliwości rozpoznania miejsc niebezpiecznych i zagrożeń za pomocą znaków/ urządzeń ostrzegawczych + PN-EN 12604 Bramy E Aspekty mechaniczne: - Projekt i konstrukcja; - Ochrona przed niezamierzonym lub niekontrolowanym ruchem; - Sily do obslugi recznej; - Urzadzenia do obslugi recznej – sprawdzenie/kontrola umiejscowienia i bezpieczenstwa konstrukcji uchwytow pod katem zagrozenia zgnieceniem, pochwyceniem lub przecieciem reki; - Ochrona palcow; - Weryfikacja specjalnych wymagan dotyczacych elementow stosowanych w systemach zawieszenia i rownowazenia; - Drzwi przejsciowe - sprawdzenie/ kontrole wzrokowe bezpiecznego polozenia, zabezpieczenia przed mimowolnym ruchem oraz wymagan dotyczacych progow; - Znaki i/lub urzadzenia ostrzegawcze – sprawdzenie i kontrola wzrokowa mozliwosci rozpoznania miejsc niebezpiecznych i zagrozen za pomoca znakow/ urzadzen ostrzegawczych + PN-EN 12604","categories":["other"],"row_index":82,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gates E Mechanical aspects: - Design and construction; - Protection against unintended or uncontrolled movement; - Manual operating forces; - Manual operating devices – checking/inspection of the location and safe design of handles with regard to the risk of crushing, trapping or cutting of the hand; - Finger protection; - Verification of special requirements for components used in suspension and counterbalancing systems; - Pass doors - checking/ visual inspection of the safe position, protection against unintended movement and requirements for thresholds; - Warning signs and/or devices – checking and visual inspection of the possibility of identifying dangerous places and hazards by means of warning signs/ devices + PN-EN 12604","search_zh":"大门 E PN-EN 12604","test_object_zh":"大门 E"},{"_id":"6a5a55f19af9f73f38250f67","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drogowe urządzenia przeciwhałasowe E","test_object_en":"Road traffic noise reducing devices E","methodology":"Ciężar własny","methodology_en":"Self-weight","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciężar własny","reference":"PN-EN 1794-1 „N”","norm_bases":["PN-EN 1794-1 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drogowe urządzenia przeciwhałasowe E Ciężar własny PN-EN 1794-1 „N” Drogowe urzadzenia przeciwhalasowe E Ciezar wlasny PN-EN 1794-1 „N”","categories":["other"],"row_index":83,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Road traffic noise reducing devices E Self-weight PN-EN 1794-1 „N”","search_zh":"道路降噪设施 E PN-EN 1794-1 „N”","test_object_zh":"道路降噪设施 E"},{"_id":"6a5a55f19af9f73f38250f68","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drogowe urządzenia przeciwhałasowe E","test_object_en":"Road traffic noise reducing devices E","methodology":"Odporność na spadające odłamki Zakres: ciało o masie 45 kg","methodology_en":"Resistance to falling fragments Range: body with a mass of 45 kg","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na spadające odłamki Zakres: ciało o masie 45 kg","reference":"PN-EN 1794-2 „N”","norm_bases":["PN-EN 1794-2 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drogowe urządzenia przeciwhałasowe E Odporność na spadające odłamki Zakres: ciało o masie 45 kg PN-EN 1794-2 „N” Drogowe urzadzenia przeciwhalasowe E Odpornosc na spadajace odlamki Zakres: cialo o masie 45 kg PN-EN 1794-2 „N”","categories":["other"],"row_index":84,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Road traffic noise reducing devices E Resistance to falling fragments Range: body with a mass of 45 kg PN-EN 1794-2 „N”","search_zh":"道路降噪设施 E PN-EN 1794-2 „N”","test_object_zh":"道路降噪设施 E"},{"_id":"6a5a55f19af9f73f38250f69","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drogowe urządzenia przeciwhałasowe E","test_object_en":"Road traffic noise reducing devices E","methodology":"Bezpieczeństwo drugorzędne Odporność na spadające odłamki Zakres: ciało o masie 400 kg","methodology_en":"Secondary safety Resistance to falling debris Range: body with a mass of 400 kg","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Bezpieczeństwo drugorzędne Odporność na spadające odłamki Zakres: ciało o masie 400 kg","reference":"PN-EN 1794-2 „N”","norm_bases":["PN-EN 1794-2 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drogowe urządzenia przeciwhałasowe E Bezpieczeństwo drugorzędne Odporność na spadające odłamki Zakres: ciało o masie 400 kg PN-EN 1794-2 „N” Drogowe urzadzenia przeciwhalasowe E Bezpieczenstwo drugorzedne Odpornosc na spadajace odlamki Zakres: cialo o masie 400 kg PN-EN 1794-2 „N”","categories":["other"],"row_index":85,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Road traffic noise reducing devices E Secondary safety Resistance to falling debris Range: body with a mass of 400 kg PN-EN 1794-2 „N”","search_zh":"道路降噪设施 E PN-EN 1794-2 „N”","test_object_zh":"道路降噪设施 E"},{"_id":"6a5a55f19af9f73f38250f6a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drogowe urządzenia przeciwhałasowe E","test_object_en":"Road traffic noise reducing devices E","methodology":"Obciążenie wiatrem i obciążenia statyczne","methodology_en":"Wind load and static loads","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Obciążenie wiatrem i obciążenia statyczne","reference":"PN-EN 1794-1 „N”","norm_bases":["PN-EN 1794-1 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drogowe urządzenia przeciwhałasowe E Obciążenie wiatrem i obciążenia statyczne PN-EN 1794-1 „N” Drogowe urzadzenia przeciwhalasowe E Obciazenie wiatrem i obciazenia statyczne PN-EN 1794-1 „N”","categories":["other"],"row_index":86,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Road traffic noise reducing devices E Wind load and static loads PN-EN 1794-1 „N”","search_zh":"道路降噪设施 E PN-EN 1794-1 „N”","test_object_zh":"道路降噪设施 E"},{"_id":"6a5a55f19af9f73f38250f6b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drogowe urządzenia przeciwhałasowe E","test_object_en":"Road traffic noise reducing devices E","methodology":"Odporność na obciążenie dynamiczne związane z odśnieżaniem","methodology_en":"Resistance to dynamic load associated with snow removal","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenie dynamiczne związane z odśnieżaniem","reference":"PN-EN 1794-1 „N”","norm_bases":["PN-EN 1794-1 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drogowe urządzenia przeciwhałasowe E Odporność na obciążenie dynamiczne związane z odśnieżaniem PN-EN 1794-1 „N” Drogowe urzadzenia przeciwhalasowe E Odpornosc na obciazenie dynamiczne zwiazane z odsniezaniem PN-EN 1794-1 „N”","categories":["other"],"row_index":87,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Road traffic noise reducing devices E Resistance to dynamic load associated with snow removal PN-EN 1794-1 „N”","search_zh":"道路降噪设施 E PN-EN 1794-1 „N”","test_object_zh":"道路降噪设施 E"},{"_id":"6a5a55f19af9f73f38250f6c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drogowe urządzenia przeciwhałasowe E","test_object_en":"Road traffic noise reducing devices E","methodology":"Odporność na uderzenie kamieni","methodology_en":"Stone impact resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie kamieni","reference":"PN-EN 1794-1 „N”","norm_bases":["PN-EN 1794-1 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drogowe urządzenia przeciwhałasowe E Odporność na uderzenie kamieni PN-EN 1794-1 „N” Drogowe urzadzenia przeciwhalasowe E Odpornosc na uderzenie kamieni PN-EN 1794-1 „N”","categories":["other"],"row_index":88,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Road traffic noise reducing devices E Stone impact resistance PN-EN 1794-1 „N”","search_zh":"道路降噪设施 E PN-EN 1794-1 „N”","test_object_zh":"道路降噪设施 E"},{"_id":"6a5a55f19af9f73f38250f6d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drogowe urządzenia przeciwhałasowe E","test_object_en":"Road traffic noise reducing devices E","methodology":"Obciążenie wiatrem i obciążenia statyczne Metoda obliczeniowa","methodology_en":"Wind load and static loads Calculation method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Obciążenie wiatrem i obciążenia statyczne Metoda obliczeniowa","reference":"LK-145 | PN-EN 1794-1 „N”","norm_bases":["LK-145","PN-EN 1794-1 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drogowe urządzenia przeciwhałasowe E Obciążenie wiatrem i obciążenia statyczne Metoda obliczeniowa LK-145 | PN-EN 1794-1 „N” Drogowe urzadzenia przeciwhalasowe E Obciazenie wiatrem i obciazenia statyczne Metoda obliczeniowa LK-145 | PN-EN 1794-1 „N”","categories":["other"],"row_index":89,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Road traffic noise reducing devices E Wind load and static loads Calculation method LK-145 | PN-EN 1794-1 „N”","search_zh":"道路降噪设施 E LK-145 | PN-EN 1794-1 „N”","test_object_zh":"道路降噪设施 E"},{"_id":"6a5a55f19af9f73f38250f6e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Nośność urządzeń zabezpieczających","methodology_en":"Load-bearing capacity of safety devices","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność urządzeń zabezpieczających","reference":"PN-EN 14351-1 PN-EN 948 „N”","norm_bases":["PN-EN 14351-1 PN-EN 948 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Nośność urządzeń zabezpieczających PN-EN 14351-1 PN-EN 948 „N” Drzwi, zespoly drzwiowe, skrzydla, oscieznice: E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Nosnosc urzadzen zabezpieczajacych PN-EN 14351-1 PN-EN 948 „N”","categories":["other"],"row_index":90,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Load-bearing capacity of safety devices PN-EN 14351-1 PN-EN 948 „N”","search_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 安全装置的承载力 PN-EN 14351-1 PN-EN 948 „N”","test_object_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用","methodology_zh":"安全装置的承载力"},{"_id":"6a5a55f19af9f73f38250f6f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Odporność na działanie różnych klimatów","methodology_en":"Resistance to various climates","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie różnych klimatów","reference":"PN-EN 1121","norm_bases":["PN-EN 1121"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odporność na działanie różnych klimatów PN-EN 1121 Drzwi, zespoly drzwiowe, skrzydla, oscieznice: E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odpornosc na dzialanie roznych klimatow PN-EN 1121","categories":["other"],"row_index":91,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Resistance to various climates PN-EN 1121","search_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 PN-EN 1121","test_object_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用"},{"_id":"6a5a55f19af9f73f38250f70","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Odporność na obciążenia pionowe Metoda obciążeń statycznych +","methodology_en":"Resistance to vertical loads Static load method +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenia pionowe Metoda obciążeń statycznych +","reference":"PN-EN 947","norm_bases":["PN-EN 947"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odporność na obciążenia pionowe Metoda obciążeń statycznych + PN-EN 947 Drzwi, zespoly drzwiowe, skrzydla, oscieznice: E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odpornosc na obciazenia pionowe Metoda obciazen statycznych + PN-EN 947","categories":["other"],"row_index":92,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Resistance to vertical loads Static load method + PN-EN 947","search_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 PN-EN 947","test_object_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用"},{"_id":"6a5a55f19af9f73f38250f71","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Odporność na obciążenie statyczne Metoda obciążeń statycznych","methodology_en":"Resistance to static load Static load method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenie statyczne Metoda obciążeń statycznych","reference":"PN-EN 1527","norm_bases":["PN-EN 1527"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odporność na obciążenie statyczne Metoda obciążeń statycznych PN-EN 1527 Drzwi, zespoly drzwiowe, skrzydla, oscieznice: E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odpornosc na obciazenie statyczne Metoda obciazen statycznych PN-EN 1527","categories":["other"],"row_index":93,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Resistance to static load Static load method PN-EN 1527","search_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 PN-EN 1527","test_object_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用"},{"_id":"6a5a55f19af9f73f38250f72","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Odporność na obciążenie wiatrem Zakres: ciśnienie (–5000 - +5000) Pa +","methodology_en":"Resistance to wind load Range: pressure (–5000 - +5000) Pa +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenie wiatrem Zakres: ciśnienie (–5000 - +5000) Pa +","reference":"PN-EN 12211 „N” PN-EN 16361","norm_bases":["PN-EN 12211 „N” PN-EN 16361"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odporność na obciążenie wiatrem Zakres: ciśnienie (–5000 - +5000) Pa + PN-EN 12211 „N” PN-EN 16361 Drzwi, zespoly drzwiowe, skrzydla, oscieznice: E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odpornosc na obciazenie wiatrem Zakres: cisnienie (–5000 - +5000) Pa + PN-EN 12211 „N” PN-EN 16361","categories":["other"],"row_index":94,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Resistance to wind load Range: pressure (–5000 - +5000) Pa + PN-EN 12211 „N” PN-EN 16361","search_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 PN-EN 12211 „N” PN-EN 16361","test_object_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用"},{"_id":"6a5a55f19af9f73f38250f73","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Odporność na uderzenie ciałem miękkim i ciężkim Zakres: ciało o masie 30 kg lub 50 kg +","methodology_en":"Soft and heavy body impact resistance Range: body with a mass of 30 kg or 50 kg +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie ciałem miękkim i ciężkim Zakres: ciało o masie 30 kg lub 50 kg +","reference":"PN-EN 949 PN-EN 13049 „N” PN-EN 16361 PN-EN 14351-2 + PN-EN 12600","norm_bases":["PN-EN 949 PN-EN 13049 „N” PN-EN 16361 PN-EN 14351-2 + PN-EN 12600"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odporność na uderzenie ciałem miękkim i ciężkim Zakres: ciało o masie 30 kg lub 50 kg + PN-EN 949 PN-EN 13049 „N” PN-EN 16361 PN-EN 14351-2 + PN-EN 12600 Drzwi, zespoly drzwiowe, skrzydla, oscieznice: E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odpornosc na uderzenie cialem miekkim i ciezkim Zakres: cialo o masie 30 kg lub 50 kg + PN-EN 949 PN-EN 13049 „N” PN-EN 16361 PN-EN 14351-2 + PN-EN 12600","categories":["other"],"row_index":95,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Soft and heavy body impact resistance Range: body with a mass of 30 kg or 50 kg + PN-EN 949 PN-EN 13049 „N” PN-EN 16361 PN-EN 14351-2 + PN-EN 12600","search_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 PN-EN 949 PN-EN 13049 „N” PN-EN 16361 PN-EN 14351-2 + PN-EN 12600","test_object_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用"},{"_id":"6a5a55f19af9f73f38250f74","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Odporność na uderzenie ciałem twardym +","methodology_en":"Resistance to hard body impact +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie ciałem twardym +","reference":"PN-EN 950","norm_bases":["PN-EN 950"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odporność na uderzenie ciałem twardym + PN-EN 950 Drzwi, zespoly drzwiowe, skrzydla, oscieznice: E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odpornosc na uderzenie cialem twardym + PN-EN 950","categories":["other"],"row_index":96,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Resistance to hard body impact + PN-EN 950","search_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 PN-EN 950","test_object_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用"},{"_id":"6a5a55f19af9f73f38250f75","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Odporność na wielokrotne otwieranie i zamykanie Metoda automatyczna","methodology_en":"Resistance to repeated opening and closing Automatic method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na wielokrotne otwieranie i zamykanie Metoda automatyczna","reference":"PN-EN 1191","norm_bases":["PN-EN 1191"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odporność na wielokrotne otwieranie i zamykanie Metoda automatyczna PN-EN 1191 Drzwi, zespoly drzwiowe, skrzydla, oscieznice: E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odpornosc na wielokrotne otwieranie i zamykanie Metoda automatyczna PN-EN 1191","categories":["other"],"row_index":97,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Resistance to repeated opening and closing Automatic method PN-EN 1191","search_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 PN-EN 1191","test_object_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用"},{"_id":"6a5a55f19af9f73f38250f76","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Wysokość +","methodology_en":"Height +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wysokość +","reference":"PN-EN 14351-2","norm_bases":["PN-EN 14351-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wysokość + PN-EN 14351-2 Drzwi, zespoly drzwiowe, skrzydla, oscieznice: E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wysokosc + PN-EN 14351-2","categories":["other"],"row_index":98,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Height + PN-EN 14351-2","search_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 高度 + PN-EN 14351-2","test_object_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用","methodology_zh":"高度 +"},{"_id":"6a5a55f19af9f73f38250f77","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Szerokość +","methodology_en":"Width +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szerokość +","reference":"PN-EN 14351-2","norm_bases":["PN-EN 14351-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Szerokość + PN-EN 14351-2 Drzwi, zespoly drzwiowe, skrzydla, oscieznice: E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Szerokosc + PN-EN 14351-2","categories":["other"],"row_index":99,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Width + PN-EN 14351-2","search_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 PN-EN 14351-2","test_object_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用"},{"_id":"6a5a55f19af9f73f38250f78","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Płaskość ogólna i miejscowa","methodology_en":"Overall and local flatness","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Płaskość ogólna i miejscowa","reference":"PN-EN 952","norm_bases":["PN-EN 952"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Płaskość ogólna i miejscowa PN-EN 952 Drzwi, zespoly drzwiowe, skrzydla, oscieznice: E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Plaskosc ogolna i miejscowa PN-EN 952","categories":["other"],"row_index":100,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Overall and local flatness PN-EN 952","search_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 PN-EN 952","test_object_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用"},{"_id":"6a5a55f19af9f73f38250f79","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Płynność działania","methodology_en":"Smoothness of operation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Płynność działania","reference":"PN-EN 1527","norm_bases":["PN-EN 1527"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Płynność działania PN-EN 1527 Drzwi, zespoly drzwiowe, skrzydla, oscieznice: E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Plynnosc dzialania PN-EN 1527","categories":["other"],"row_index":101,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Smoothness of operation PN-EN 1527","search_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 PN-EN 1527","test_object_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用"},{"_id":"6a5a55f19af9f73f38250f7a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Przepuszczalność powietrza +","methodology_en":"Air permeability +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność powietrza +","reference":"PN-EN 1026 „N” PN-EN 16361 PN-EN 14351-2","norm_bases":["PN-EN 1026 „N” PN-EN 16361 PN-EN 14351-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Przepuszczalność powietrza + PN-EN 1026 „N” PN-EN 16361 PN-EN 14351-2 Drzwi, zespoly drzwiowe, skrzydla, oscieznice: E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Przepuszczalnosc powietrza + PN-EN 1026 „N” PN-EN 16361 PN-EN 14351-2","categories":["other"],"row_index":102,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Air permeability + PN-EN 1026 „N” PN-EN 16361 PN-EN 14351-2","search_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 透气性 + PN-EN 1026 „N” PN-EN 16361 PN-EN 14351-2","test_object_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用","methodology_zh":"透气性 +"},{"_id":"6a5a55f19af9f73f38250f7b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Samoczynne zamykanie","methodology_en":"Self-closing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Samoczynne zamykanie","reference":"PN-EN 16034","norm_bases":["PN-EN 16034"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Samoczynne zamykanie PN-EN 16034 Drzwi, zespoly drzwiowe, skrzydla, oscieznice: E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Samoczynne zamykanie PN-EN 16034","categories":["other"],"row_index":103,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Self-closing PN-EN 16034","search_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 自闭合 PN-EN 16034","test_object_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用","methodology_zh":"自闭合"},{"_id":"6a5a55f19af9f73f38250f7c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Siła potrzebna do rozpoczęcia ruchu skrzydła (tarcie początkowe)","methodology_en":"Force needed to start the movement of the leaf (initial friction)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła potrzebna do rozpoczęcia ruchu skrzydła (tarcie początkowe)","reference":"PN-EN 1527","norm_bases":["PN-EN 1527"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Siła potrzebna do rozpoczęcia ruchu skrzydła (tarcie początkowe) PN-EN 1527 Drzwi, zespoly drzwiowe, skrzydla, oscieznice: E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Sila potrzebna do rozpoczecia ruchu skrzydla (tarcie poczatkowe) PN-EN 1527","categories":["other"],"row_index":104,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Force needed to start the movement of the leaf (initial friction) PN-EN 1527","search_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 PN-EN 1527","test_object_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用"},{"_id":"6a5a55f19af9f73f38250f7d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Siły operacyjne +","methodology_en":"Operating forces +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siły operacyjne +","reference":"PN-EN 12046-2 PN-EN 16361","norm_bases":["PN-EN 12046-2 PN-EN 16361"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Siły operacyjne + PN-EN 12046-2 PN-EN 16361 Drzwi, zespoly drzwiowe, skrzydla, oscieznice: E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Sily operacyjne + PN-EN 12046-2 PN-EN 16361","categories":["other"],"row_index":105,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Operating forces + PN-EN 12046-2 PN-EN 16361","search_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 操作力 + PN-EN 12046-2 PN-EN 16361","test_object_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用","methodology_zh":"操作力 +"},{"_id":"6a5a55f19af9f73f38250f7e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Trwałość samoczynnego zamykania","methodology_en":"Durability of self-closing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość samoczynnego zamykania","reference":"PN-EN 16034","norm_bases":["PN-EN 16034"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Trwałość samoczynnego zamykania PN-EN 16034 Drzwi, zespoly drzwiowe, skrzydla, oscieznice: E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Trwalosc samoczynnego zamykania PN-EN 16034","categories":["other"],"row_index":106,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Durability of self-closing PN-EN 16034","search_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 自闭合耐久性 PN-EN 16034","test_object_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用","methodology_zh":"自闭合耐久性"},{"_id":"6a5a55f19af9f73f38250f7f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Wodoszczelność + Zakres: do 5000 Pa","methodology_en":"Watertightness + Range: up to 5000 Pa","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność + Zakres: do 5000 Pa","reference":"PN-EN 1027 „N” PN-EN 16361","norm_bases":["PN-EN 1027 „N” PN-EN 16361"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wodoszczelność + Zakres: do 5000 Pa PN-EN 1027 „N” PN-EN 16361 Drzwi, zespoly drzwiowe, skrzydla, oscieznice: E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wodoszczelnosc + Zakres: do 5000 Pa PN-EN 1027 „N” PN-EN 16361","categories":["other"],"row_index":107,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Watertightness + Range: up to 5000 Pa PN-EN 1027 „N” PN-EN 16361","search_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 PN-EN 1027 „N” PN-EN 16361","test_object_zh":"门、门组件、门扇、门框：E — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 耐火 — 阻烟 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用"},{"_id":"6a5a55f19af9f73f38250f80","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, doorsets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire-resistant - smoke-tight - manually operated and power-operated - with panic hardware - on escape routes","methodology":"Wymiary i odchyłki od prostokątności skrzydeł +","methodology_en":"Dimensions and deviations from squareness of the leaves +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary i odchyłki od prostokątności skrzydeł +","reference":"PN-EN 951","norm_bases":["PN-EN 951"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wymiary i odchyłki od prostokątności skrzydeł + PN-EN 951 Drzwi, zespoly drzwiowe, skrzydla, oscieznice: E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wymiary i odchylki od prostokatnosci skrzydel + PN-EN 951","categories":["other"],"row_index":108,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, doorsets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire-resistant - smoke-tight - manually operated and power-operated - with panic hardware - on escape routes Dimensions and deviations from squareness of the leaves + PN-EN 951","search_zh":"门、门组件、门扇、门框：E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道 PN-EN 951","test_object_zh":"门、门组件、门扇、门框：E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道"},{"_id":"6a5a55f19af9f73f38250f81","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, doorsets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire-resistant - smoke-tight - manually operated and power-operated - with panic hardware - on escape routes","methodology":"Wysokość i szerokość + Metoda pomiaru liniowego","methodology_en":"Height and width + Linear measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wysokość i szerokość + Metoda pomiaru liniowego","reference":"PN-EN 14351-1 PN-EN 16361","norm_bases":["PN-EN 14351-1 PN-EN 16361"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wysokość i szerokość + Metoda pomiaru liniowego PN-EN 14351-1 PN-EN 16361 Drzwi, zespoly drzwiowe, skrzydla, oscieznice: E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wysokosc i szerokosc + Metoda pomiaru liniowego PN-EN 14351-1 PN-EN 16361","categories":["other"],"row_index":109,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, doorsets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire-resistant - smoke-tight - manually operated and power-operated - with panic hardware - on escape routes Height and width + Linear measurement method PN-EN 14351-1 PN-EN 16361","search_zh":"门、门组件、门扇、门框：E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道 PN-EN 14351-1 PN-EN 16361","test_object_zh":"门、门组件、门扇、门框：E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道"},{"_id":"6a5a55f19af9f73f38250f82","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, doorsets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire-resistant - smoke-tight - manually operated and power-operated - with panic hardware - on escape routes","methodology":"Wytrzymałość na skręcanie statyczne Metoda obciążeń statycznych +","methodology_en":"Static torsional strength Static loading method +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na skręcanie statyczne Metoda obciążeń statycznych +","reference":"PN-EN 948","norm_bases":["PN-EN 948"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wytrzymałość na skręcanie statyczne Metoda obciążeń statycznych + PN-EN 948 Drzwi, zespoly drzwiowe, skrzydla, oscieznice: E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wytrzymalosc na skrecanie statyczne Metoda obciazen statycznych + PN-EN 948","categories":["other"],"row_index":110,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, doorsets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire-resistant - smoke-tight - manually operated and power-operated - with panic hardware - on escape routes Static torsional strength Static loading method + PN-EN 948","search_zh":"门、门组件、门扇、门框：E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道 PN-EN 948","test_object_zh":"门、门组件、门扇、门框：E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道"},{"_id":"6a5a55f19af9f73f38250f83","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, doorsets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire-resistant - smoke-tight - manually operated and power-operated - with panic hardware - on escape routes","methodology":"Wytrzymałość połączeń skrzydełek zawiasów z ościeżnicą na obciążenia statyczne siłą skupioną w płaszczyźnie skrzydła Metoda obciążeń statycznych","methodology_en":"Strength of the connections of the hinge leaves to the frame under static loading by a concentrated force in the plane of the leaf Static loading method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość połączeń skrzydełek zawiasów z ościeżnicą na obciążenia statyczne siłą skupioną w płaszczyźnie skrzydła Metoda obciążeń statycznych","reference":"PN-EN 947","norm_bases":["PN-EN 947"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wytrzymałość połączeń skrzydełek zawiasów z ościeżnicą na obciążenia statyczne siłą skupioną w płaszczyźnie skrzydła Metoda obciążeń statycznych PN-EN 947 Drzwi, zespoly drzwiowe, skrzydla, oscieznice: E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wytrzymalosc polaczen skrzydelek zawiasow z oscieznica na obciazenia statyczne sila skupiona w plaszczyznie skrzydla Metoda obciazen statycznych PN-EN 947","categories":["other"],"row_index":111,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, doorsets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire-resistant - smoke-tight - manually operated and power-operated - with panic hardware - on escape routes Strength of the connections of the hinge leaves to the frame under static loading by a concentrated force in the plane of the leaf Static loading method PN-EN 947","search_zh":"门、门组件、门扇、门框：E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道 PN-EN 947","test_object_zh":"门、门组件、门扇、门框：E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道"},{"_id":"6a5a55f19af9f73f38250f84","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, doorsets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire-resistant - smoke-tight - manually operated and power-operated - with panic hardware - on escape routes","methodology":"Zdolność do zwolnienia","methodology_en":"Release capability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność do zwolnienia","reference":"PN-EN 1125 PN-EN 179 PN-EN 14351-2","norm_bases":["PN-EN 1125 PN-EN 179 PN-EN 14351-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice: E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Zdolność do zwolnienia PN-EN 1125 PN-EN 179 PN-EN 14351-2 Drzwi, zespoly drzwiowe, skrzydla, oscieznice: E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Zdolnosc do zwolnienia PN-EN 1125 PN-EN 179 PN-EN 14351-2","categories":["other"],"row_index":112,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, doorsets, leaves, frames: E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire-resistant - smoke-tight - manually operated and power-operated - with panic hardware - on escape routes Release capability PN-EN 1125 PN-EN 179 PN-EN 14351-2","search_zh":"门、门组件、门扇、门框：E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道 释放能力 PN-EN 1125 PN-EN 179 PN-EN 14351-2","test_object_zh":"门、门组件、门扇、门框：E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道","methodology_zh":"释放能力"},{"_id":"6a5a55f19af9f73f38250f85","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy budynków: E - ściany - ściany osłonowe - dachy - przekrycia - inne","test_object_en":"Building elements: E - walls - curtain walls - roofs - roof coverings - other","methodology":"Odporność na obciążenie poziome i ciężar własny Metoda obliczeniowa","methodology_en":"Resistance to horizontal load and self-weight Calculation method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenie poziome i ciężar własny Metoda obliczeniowa","reference":"PN-EN 13830 „N” PB LK-131","norm_bases":["PN-EN 13830 „N” PB LK-131"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy budynków: E - ściany - ściany osłonowe - dachy - przekrycia - inne Odporność na obciążenie poziome i ciężar własny Metoda obliczeniowa PN-EN 13830 „N” PB LK-131 Elementy budynkow: E - sciany - sciany oslonowe - dachy - przekrycia - inne Odpornosc na obciazenie poziome i ciezar wlasny Metoda obliczeniowa PN-EN 13830 „N” PB LK-131","categories":["construction"],"row_index":113,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building elements: E - walls - curtain walls - roofs - roof coverings - other Resistance to horizontal load and self-weight Calculation method PN-EN 13830 „N” PB LK-131","search_zh":"建筑构件：E － 墙体 － 幕墙 － 屋面 － 覆盖结构 － 其他 PN-EN 13830 „N” PB LK-131","test_object_zh":"建筑构件：E － 墙体 － 幕墙 － 屋面 － 覆盖结构 － 其他"},{"_id":"6a5a55f19af9f73f38250f86","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy budynków: E - ściany - ściany osłonowe - dachy - przekrycia - inne","test_object_en":"Building elements: E - walls - curtain walls - roofs - roof coverings - other","methodology":"Odporność na obciążenie wiatrem Zakres: ciśnienie (–5000 - +5000) Pa Metoda równomiernego obciążenia","methodology_en":"Resistance to wind load Range: pressure (–5000 - +5000) Pa Uniform loading method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenie wiatrem Zakres: ciśnienie (–5000 - +5000) Pa Metoda równomiernego obciążenia","reference":"PN-EN 12179 PN-EN 13116","norm_bases":["PN-EN 12179 PN-EN 13116"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy budynków: E - ściany - ściany osłonowe - dachy - przekrycia - inne Odporność na obciążenie wiatrem Zakres: ciśnienie (–5000 - +5000) Pa Metoda równomiernego obciążenia PN-EN 12179 PN-EN 13116 Elementy budynkow: E - sciany - sciany oslonowe - dachy - przekrycia - inne Odpornosc na obciazenie wiatrem Zakres: cisnienie (–5000 - +5000) Pa Metoda rownomiernego obciazenia PN-EN 12179 PN-EN 13116","categories":["construction"],"row_index":114,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building elements: E - walls - curtain walls - roofs - roof coverings - other Resistance to wind load Range: pressure (–5000 - +5000) Pa Uniform loading method PN-EN 12179 PN-EN 13116","search_zh":"建筑构件：E － 墙体 － 幕墙 － 屋面 － 覆盖结构 － 其他 PN-EN 12179 PN-EN 13116","test_object_zh":"建筑构件：E － 墙体 － 幕墙 － 屋面 － 覆盖结构 － 其他"},{"_id":"6a5a55f19af9f73f38250f87","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy budynków: E - ściany - ściany osłonowe - dachy - przekrycia - inne","test_object_en":"Building elements: E - walls - curtain walls - roofs - roof coverings - other","methodology":"Odporność na uderzenie ciałem miękkim i ciężkim","methodology_en":"Resistance to soft and heavy body impact","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie ciałem miękkim i ciężkim","reference":"PN-EN 13049 „N” PN-EN 14019 „N” PN-EN 12600 „N”","norm_bases":["PN-EN 13049 „N” PN-EN 14019 „N” PN-EN 12600 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy budynków: E - ściany - ściany osłonowe - dachy - przekrycia - inne Odporność na uderzenie ciałem miękkim i ciężkim PN-EN 13049 „N” PN-EN 14019 „N” PN-EN 12600 „N” Elementy budynkow: E - sciany - sciany oslonowe - dachy - przekrycia - inne Odpornosc na uderzenie cialem miekkim i ciezkim PN-EN 13049 „N” PN-EN 14019 „N” PN-EN 12600 „N”","categories":["construction"],"row_index":115,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building elements: E - walls - curtain walls - roofs - roof coverings - other Resistance to soft and heavy body impact PN-EN 13049 „N” PN-EN 14019 „N” PN-EN 12600 „N”","methodology_zh":"软体与硬重物撞击抗力","search_zh":"建筑构件：E － 墙体 － 幕墙 － 屋面 － 覆盖结构 － 其他 软体与硬重物撞击抗力 PN-EN 13049 „N” PN-EN 14019 „N” PN-EN 12600 „N”","test_object_zh":"建筑构件：E － 墙体 － 幕墙 － 屋面 － 覆盖结构 － 其他"},{"_id":"6a5a55f19af9f73f38250f88","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy budynków: E - ściany - ściany osłonowe - dachy - przekrycia - inne","test_object_en":"Building elements: E - walls - curtain walls - roofs - roof coverings - other","methodology":"Przepuszczalność powietrza","methodology_en":"Air permeability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność powietrza","reference":"PN-EN 12153 PN-EN 12152 PN-EN 12114","norm_bases":["PN-EN 12153 PN-EN 12152 PN-EN 12114"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy budynków: E - ściany - ściany osłonowe - dachy - przekrycia - inne Przepuszczalność powietrza PN-EN 12153 PN-EN 12152 PN-EN 12114 Elementy budynkow: E - sciany - sciany oslonowe - dachy - przekrycia - inne Przepuszczalnosc powietrza PN-EN 12153 PN-EN 12152 PN-EN 12114","categories":["construction"],"row_index":116,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building elements: E - walls - curtain walls - roofs - roof coverings - other Air permeability PN-EN 12153 PN-EN 12152 PN-EN 12114","methodology_zh":"透气性","search_zh":"建筑构件：E － 墙体 － 幕墙 － 屋面 － 覆盖结构 － 其他 透气性 PN-EN 12153 PN-EN 12152 PN-EN 12114","test_object_zh":"建筑构件：E － 墙体 － 幕墙 － 屋面 － 覆盖结构 － 其他"},{"_id":"6a5a55f19af9f73f38250f89","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy budynków: E - ściany - ściany osłonowe - dachy - przekrycia - inne","test_object_en":"Building elements: E - walls - curtain walls - roofs - roof coverings - other","methodology":"Wodoszczelność Metoda poligonowa","methodology_en":"Watertightness Field test method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność Metoda poligonowa","reference":"PN-EN 13051","norm_bases":["PN-EN 13051"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy budynków: E - ściany - ściany osłonowe - dachy - przekrycia - inne Wodoszczelność Metoda poligonowa PN-EN 13051 Elementy budynkow: E - sciany - sciany oslonowe - dachy - przekrycia - inne Wodoszczelnosc Metoda poligonowa PN-EN 13051","categories":["construction"],"row_index":117,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building elements: E - walls - curtain walls - roofs - roof coverings - other Watertightness Field test method PN-EN 13051","search_zh":"建筑构件：E － 墙体 － 幕墙 － 屋面 － 覆盖结构 － 其他 PN-EN 13051","test_object_zh":"建筑构件：E － 墙体 － 幕墙 － 屋面 － 覆盖结构 － 其他"},{"_id":"6a5a55f19af9f73f38250f8a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy budynków: E - ściany - ściany osłonowe - dachy - przekrycia - inne","test_object_en":"Building elements: E - walls - curtain walls - roofs - roof coverings - other","methodology":"Wodoszczelność Zakres: ciśnienie do 5000 Pa","methodology_en":"Watertightness Range: pressure up to 5000 Pa","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność Zakres: ciśnienie do 5000 Pa","reference":"PN-EN 12155 „N” PN-EN 12154","norm_bases":["PN-EN 12155 „N” PN-EN 12154"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy budynków: E - ściany - ściany osłonowe - dachy - przekrycia - inne Wodoszczelność Zakres: ciśnienie do 5000 Pa PN-EN 12155 „N” PN-EN 12154 Elementy budynkow: E - sciany - sciany oslonowe - dachy - przekrycia - inne Wodoszczelnosc Zakres: cisnienie do 5000 Pa PN-EN 12155 „N” PN-EN 12154","categories":["construction"],"row_index":118,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building elements: E - walls - curtain walls - roofs - roof coverings - other Watertightness Range: pressure up to 5000 Pa PN-EN 12155 „N” PN-EN 12154","search_zh":"建筑构件：E － 墙体 － 幕墙 － 屋面 － 覆盖结构 － 其他 PN-EN 12155 „N” PN-EN 12154","test_object_zh":"建筑构件：E － 墙体 － 幕墙 － 屋面 － 覆盖结构 － 其他"},{"_id":"6a5a55f19af9f73f38250f8b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kształtowniki metalowe z przekładką termiczną E","test_object_en":"Metal profiles with thermal break E","methodology":"Odporność na działanie wilgoci Zakres: do 60 kN Metoda wytrzymałościowa","methodology_en":"Resistance to moisture Range: up to 60 kN Strength method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie wilgoci Zakres: do 60 kN Metoda wytrzymałościowa","reference":"PN-EN 14024","norm_bases":["PN-EN 14024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kształtowniki metalowe z przekładką termiczną E Odporność na działanie wilgoci Zakres: do 60 kN Metoda wytrzymałościowa PN-EN 14024 Ksztaltowniki metalowe z przekladka termiczna E Odpornosc na dzialanie wilgoci Zakres: do 60 kN Metoda wytrzymalosciowa PN-EN 14024","categories":["materials"],"row_index":119,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Metal profiles with thermal break E Resistance to moisture Range: up to 60 kN Strength method PN-EN 14024","search_zh":"带隔热条的金属型材 E PN-EN 14024","test_object_zh":"带隔热条的金属型材 E"},{"_id":"6a5a55f19af9f73f38250f8c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kształtowniki metalowe z przekładką termiczną E","test_object_en":"Metal profiles with thermal break E","methodology":"Odporność po zanurzeniu w wodzie Zakres: do 60 kN Metoda wytrzymałościowa","methodology_en":"Resistance after immersion in water Range: up to 60 kN Strength method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność po zanurzeniu w wodzie Zakres: do 60 kN Metoda wytrzymałościowa","reference":"PN-EN 14024","norm_bases":["PN-EN 14024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kształtowniki metalowe z przekładką termiczną E Odporność po zanurzeniu w wodzie Zakres: do 60 kN Metoda wytrzymałościowa PN-EN 14024 Ksztaltowniki metalowe z przekladka termiczna E Odpornosc po zanurzeniu w wodzie Zakres: do 60 kN Metoda wytrzymalosciowa PN-EN 14024","categories":["materials"],"row_index":120,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Metal profiles with thermal break E Resistance after immersion in water Range: up to 60 kN Strength method PN-EN 14024","search_zh":"带隔热条的金属型材 E PN-EN 14024","test_object_zh":"带隔热条的金属型材 E"},{"_id":"6a5a55f19af9f73f38250f8d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kształtowniki metalowe z przekładką termiczną E","test_object_en":"Metal profiles with thermal break E","methodology":"Wytrzymałość na rozciąganie poprzeczne (Q) Zakres: do 60 kN Metoda rozciągania","methodology_en":"Transverse tensile strength (Q) Range: up to 60 kN Tensile method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na rozciąganie poprzeczne (Q) Zakres: do 60 kN Metoda rozciągania","reference":"PN-EN 14024","norm_bases":["PN-EN 14024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kształtowniki metalowe z przekładką termiczną E Wytrzymałość na rozciąganie poprzeczne (Q) Zakres: do 60 kN Metoda rozciągania PN-EN 14024 Ksztaltowniki metalowe z przekladka termiczna E Wytrzymalosc na rozciaganie poprzeczne (Q) Zakres: do 60 kN Metoda rozciagania PN-EN 14024","categories":["materials"],"row_index":121,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Metal profiles with thermal break E Transverse tensile strength (Q) Range: up to 60 kN Tensile method PN-EN 14024","search_zh":"带隔热条的金属型材 E PN-EN 14024","test_object_zh":"带隔热条的金属型材 E"},{"_id":"6a5a55f19af9f73f38250f8e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kształtowniki metalowe z przekładką termiczną E","test_object_en":"Metal profiles with thermal break E","methodology":"Wytrzymałość na ścinanie (T) Zakres: do 60 kN Metoda ścinania","methodology_en":"Shear strength (T) Range: up to 60 kN Shear method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ścinanie (T) Zakres: do 60 kN Metoda ścinania","reference":"PN-EN 14024","norm_bases":["PN-EN 14024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kształtowniki metalowe z przekładką termiczną E Wytrzymałość na ścinanie (T) Zakres: do 60 kN Metoda ścinania PN-EN 14024 Ksztaltowniki metalowe z przekladka termiczna E Wytrzymalosc na scinanie (T) Zakres: do 60 kN Metoda scinania PN-EN 14024","categories":["materials"],"row_index":122,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Metal profiles with thermal break E Shear strength (T) Range: up to 60 kN Shear method PN-EN 14024","search_zh":"带隔热条的金属型材 E PN-EN 14024","test_object_zh":"带隔热条的金属型材 E"},{"_id":"6a5a55f19af9f73f38250f8f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu","test_object_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated","methodology":"Nośność urządzeń zabezpieczających +","methodology_en":"Load capacity of safety devices +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność urządzeń zabezpieczających +","reference":"PN-EN 14351-1 PN-EN 14609 „N”","norm_bases":["PN-EN 14351-1 PN-EN 14609 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu Nośność urządzeń zabezpieczających + PN-EN 14351-1 PN-EN 14609 „N” Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane recznie lub za pomoca napedu Nosnosc urzadzen zabezpieczajacych + PN-EN 14351-1 PN-EN 14609 „N”","categories":["construction"],"row_index":123,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated Load capacity of safety devices + PN-EN 14351-1 PN-EN 14609 „N”","search_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置 PN-EN 14351-1 PN-EN 14609 „N”","test_object_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置"},{"_id":"6a5a55f19af9f73f38250f90","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu","test_object_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated","methodology":"Odporność na obciążenia w płaszczyźnie skrzydła +","methodology_en":"Resistance to loads in the plane of the leaf +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenia w płaszczyźnie skrzydła +","reference":"PN-EN 14608 PN-EN 13115","norm_bases":["PN-EN 14608 PN-EN 13115"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu Odporność na obciążenia w płaszczyźnie skrzydła + PN-EN 14608 PN-EN 13115 Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane recznie lub za pomoca napedu Odpornosc na obciazenia w plaszczyznie skrzydla + PN-EN 14608 PN-EN 13115","categories":["construction"],"row_index":124,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated Resistance to loads in the plane of the leaf + PN-EN 14608 PN-EN 13115","search_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置 PN-EN 14608 PN-EN 13115","test_object_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置"},{"_id":"6a5a55f19af9f73f38250f91","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu","test_object_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated","methodology":"Odporność na obciążenie wiatrem + Zakres: ciśnienie (–5000 - +5000) Pa Metoda różnicy ciśnień","methodology_en":"Resistance to wind load + Range: pressure (–5000 - +5000) Pa Pressure difference method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenie wiatrem + Zakres: ciśnienie (–5000 - +5000) Pa Metoda różnicy ciśnień","reference":"PN-EN 12211 „N”","norm_bases":["PN-EN 12211 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu Odporność na obciążenie wiatrem + Zakres: ciśnienie (–5000 - +5000) Pa Metoda różnicy ciśnień PN-EN 12211 „N” Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane recznie lub za pomoca napedu Odpornosc na obciazenie wiatrem + Zakres: cisnienie (–5000 - +5000) Pa Metoda roznicy cisnien PN-EN 12211 „N”","categories":["construction"],"row_index":125,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated Resistance to wind load + Range: pressure (–5000 - +5000) Pa Pressure difference method PN-EN 12211 „N”","search_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置 PN-EN 12211 „N”","test_object_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置"},{"_id":"6a5a55f19af9f73f38250f92","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu","test_object_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated","methodology":"Odporność na skręcanie statyczne+","methodology_en":"Resistance to static torsion+","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na skręcanie statyczne+","reference":"PN-EN 14609 PN-EN 13115","norm_bases":["PN-EN 14609 PN-EN 13115"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu Odporność na skręcanie statyczne+ PN-EN 14609 PN-EN 13115 Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane recznie lub za pomoca napedu Odpornosc na skrecanie statyczne+ PN-EN 14609 PN-EN 13115","categories":["construction"],"row_index":126,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated Resistance to static torsion+ PN-EN 14609 PN-EN 13115","search_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置 PN-EN 14609 PN-EN 13115","test_object_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置"},{"_id":"6a5a55f19af9f73f38250f93","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu","test_object_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated","methodology":"Odporność na uderzenie ciałem miękkim i ciężkim + Zakres: ciało o masie 50 kg","methodology_en":"Soft and heavy body impact resistance + Range: body with a mass of 50 kg","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie ciałem miękkim i ciężkim + Zakres: ciało o masie 50 kg","reference":"PN-EN 13049 „N”","norm_bases":["PN-EN 13049 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu Odporność na uderzenie ciałem miękkim i ciężkim + Zakres: ciało o masie 50 kg PN-EN 13049 „N” Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane recznie lub za pomoca napedu Odpornosc na uderzenie cialem miekkim i ciezkim + Zakres: cialo o masie 50 kg PN-EN 13049 „N”","categories":["construction"],"row_index":127,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated Soft and heavy body impact resistance + Range: body with a mass of 50 kg PN-EN 13049 „N”","search_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置 PN-EN 13049 „N”","test_object_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置"},{"_id":"6a5a55f19af9f73f38250f94","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu","test_object_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated","methodology":"Przepuszczalność powietrza +","methodology_en":"Air permeability +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność powietrza +","reference":"PN-EN 1026 „N”","norm_bases":["PN-EN 1026 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu Przepuszczalność powietrza + PN-EN 1026 „N” Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane recznie lub za pomoca napedu Przepuszczalnosc powietrza + PN-EN 1026 „N”","categories":["construction"],"row_index":128,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated Air permeability + PN-EN 1026 „N”","search_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置 透气性 + PN-EN 1026 „N”","test_object_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置","methodology_zh":"透气性 +"},{"_id":"6a5a55f19af9f73f38250f95","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu","test_object_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated","methodology":"Siły operacyjne +","methodology_en":"Operating forces +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siły operacyjne +","reference":"PN-EN 12046-1 PN-EN 13115","norm_bases":["PN-EN 12046-1 PN-EN 13115"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu Siły operacyjne + PN-EN 12046-1 PN-EN 13115 Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane recznie lub za pomoca napedu Sily operacyjne + PN-EN 12046-1 PN-EN 13115","categories":["construction"],"row_index":129,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated Operating forces + PN-EN 12046-1 PN-EN 13115","search_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置 操作力 + PN-EN 12046-1 PN-EN 13115","test_object_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置","methodology_zh":"操作力 +"},{"_id":"6a5a55f19af9f73f38250f96","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu","test_object_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated","methodology":"Wodoszczelność + Zakres: ciśnienie do 5000 Pa","methodology_en":"Watertightness + Range: pressure up to 5000 Pa","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność + Zakres: ciśnienie do 5000 Pa","reference":"PN-EN 1027 „N”","norm_bases":["PN-EN 1027 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu Wodoszczelność + Zakres: ciśnienie do 5000 Pa PN-EN 1027 „N” Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane recznie lub za pomoca napedu Wodoszczelnosc + Zakres: cisnienie do 5000 Pa PN-EN 1027 „N”","categories":["construction"],"row_index":130,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated Watertightness + Range: pressure up to 5000 Pa PN-EN 1027 „N”","search_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置 PN-EN 1027 „N”","test_object_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置"},{"_id":"6a5a55f19af9f73f38250f97","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu","test_object_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated","methodology":"Wysokość i szerokość Metoda pomiaru liniowego","methodology_en":"Height and width Linear measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wysokość i szerokość Metoda pomiaru liniowego","reference":"PN-EN 14351-1","norm_bases":["PN-EN 14351-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu Wysokość i szerokość Metoda pomiaru liniowego PN-EN 14351-1 Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane recznie lub za pomoca napedu Wysokosc i szerokosc Metoda pomiaru liniowego PN-EN 14351-1","categories":["construction"],"row_index":131,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated Height and width Linear measurement method PN-EN 14351-1","search_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置 PN-EN 14351-1","test_object_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置"},{"_id":"6a5a55f19af9f73f38250f98","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu","test_object_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated","methodology":"Odporność na wielokrotne otwieranie i zamykanie","methodology_en":"Resistance to repeated opening and closing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na wielokrotne otwieranie i zamykanie","reference":"PN-EN 1191","norm_bases":["PN-EN 1191"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu Odporność na wielokrotne otwieranie i zamykanie PN-EN 1191 Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane recznie lub za pomoca napedu Odpornosc na wielokrotne otwieranie i zamykanie PN-EN 1191","categories":["construction"],"row_index":132,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated Resistance to repeated opening and closing PN-EN 1191","search_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置 反复启闭的耐受性 PN-EN 1191","test_object_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置","methodology_zh":"反复启闭的耐受性"},{"_id":"6a5a55f19af9f73f38250f99","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty kompozytowe E","test_object_en":"Composite panels E","methodology":"Przepuszczalność powietrza","methodology_en":"Air permeability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność powietrza","reference":"PN-EN 12114","norm_bases":["PN-EN 12114"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty kompozytowe E Przepuszczalność powietrza PN-EN 12114 Plyty kompozytowe E Przepuszczalnosc powietrza PN-EN 12114","categories":["materials"],"row_index":133,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Composite panels E Air permeability PN-EN 12114","methodology_zh":"透气性","search_zh":"透气性 PN-EN 12114"},{"_id":"6a5a55f19af9f73f38250f9a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty kompozytowe E","test_object_en":"Composite panels E","methodology":"Wodoszczelność ściany","methodology_en":"Watertightness of the wall","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność ściany","reference":"PN-EN 12865","norm_bases":["PN-EN 12865"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty kompozytowe E Wodoszczelność ściany PN-EN 12865 Plyty kompozytowe E Wodoszczelnosc sciany PN-EN 12865","categories":["materials"],"row_index":134,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Composite panels E Watertightness of the wall PN-EN 12865"},{"_id":"6a5a55f19af9f73f38250f9b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty warstwowe E","test_object_en":"Sandwich panels E","methodology":"Odporność na obciążenie skupione","methodology_en":"Resistance to concentrated load","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenie skupione","reference":"PN-EN 14509","norm_bases":["PN-EN 14509"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty warstwowe E Odporność na obciążenie skupione PN-EN 14509 Plyty warstwowe E Odpornosc na obciazenie skupione PN-EN 14509","categories":["other"],"row_index":135,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sandwich panels E Resistance to concentrated load PN-EN 14509","search_zh":"夹芯板 E PN-EN 14509","test_object_zh":"夹芯板 E"},{"_id":"6a5a55f19af9f73f38250f9c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty warstwowe E","test_object_en":"Sandwich panels E","methodology":"Współczynnik pełzania","methodology_en":"Creep coefficient","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Współczynnik pełzania","reference":"PN-EN 14509","norm_bases":["PN-EN 14509"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty warstwowe E Współczynnik pełzania PN-EN 14509 Plyty warstwowe E Wspolczynnik pelzania PN-EN 14509","categories":["other"],"row_index":136,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sandwich panels E Creep coefficient PN-EN 14509","search_zh":"夹芯板 E PN-EN 14509","test_object_zh":"夹芯板 E"},{"_id":"6a5a55f19af9f73f38250f9d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty warstwowe E","test_object_en":"Sandwich panels E","methodology":"Oddziaływanie między momentem zginającym a reakcją podpory Metoda wytrzymałościowa","methodology_en":"Interaction between bending moment and support reaction Strength method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Oddziaływanie między momentem zginającym a reakcją podpory Metoda wytrzymałościowa","reference":"PN-EN 14509","norm_bases":["PN-EN 14509"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty warstwowe E Oddziaływanie między momentem zginającym a reakcją podpory Metoda wytrzymałościowa PN-EN 14509 Plyty warstwowe E Oddzialywanie miedzy momentem zginajacym a reakcja podpory Metoda wytrzymalosciowa PN-EN 14509","categories":["other"],"row_index":137,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sandwich panels E Interaction between bending moment and support reaction Strength method PN-EN 14509","search_zh":"夹芯板 E PN-EN 14509","test_object_zh":"夹芯板 E"},{"_id":"6a5a55f19af9f73f38250f9e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty warstwowe E","test_object_en":"Sandwich panels E","methodology":"Moment zginający i sztywność płyty swobodnie podpartej Metoda wytrzymałościowa","methodology_en":"Bending moment and stiffness of a simply supported slab Strength test method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moment zginający i sztywność płyty swobodnie podpartej Metoda wytrzymałościowa","reference":"PN-EN 14509","norm_bases":["PN-EN 14509"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty warstwowe E Moment zginający i sztywność płyty swobodnie podpartej Metoda wytrzymałościowa PN-EN 14509 Plyty warstwowe E Moment zginajacy i sztywnosc plyty swobodnie podpartej Metoda wytrzymalosciowa PN-EN 14509","categories":["other"],"row_index":138,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sandwich panels E Bending moment and stiffness of a simply supported slab Strength test method PN-EN 14509","search_zh":"夹芯板 E PN-EN 14509","test_object_zh":"夹芯板 E"},{"_id":"6a5a55f19af9f73f38250f9f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Przegrody budowlane o podwyższonej odporności na włamanie w tym: E - okna - drzwi - ściany osłonowe - bramy - żaluzje - inne","test_object_en":"Building partitions with increased burglary resistance including: E - windows - doors - curtain walls - gates - shutters - others","methodology":"Odporność na badanie z zastosowaniem narzędzi Zakres: grupa wyrobów 1 klasy 2 i 3","methodology_en":"Resistance to testing using tools Range: product group 1 classes 2 and 3","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na badanie z zastosowaniem narzędzi Zakres: grupa wyrobów 1 klasy 2 i 3","reference":"PN-EN 1630","norm_bases":["PN-EN 1630"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przegrody budowlane o podwyższonej odporności na włamanie w tym: E - okna - drzwi - ściany osłonowe - bramy - żaluzje - inne Odporność na badanie z zastosowaniem narzędzi Zakres: grupa wyrobów 1 klasy 2 i 3 PN-EN 1630 Przegrody budowlane o podwyzszonej odpornosci na wlamanie w tym: E - okna - drzwi - sciany oslonowe - bramy - zaluzje - inne Odpornosc na badanie z zastosowaniem narzedzi Zakres: grupa wyrobow 1 klasy 2 i 3 PN-EN 1630","categories":["construction"],"row_index":139,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building partitions with increased burglary resistance including: E - windows - doors - curtain walls - gates - shutters - others Resistance to testing using tools Range: product group 1 classes 2 and 3 PN-EN 1630","search_zh":"具有提高抗侵入性的建筑围护构件，其中包括：E － 窗 － 门 － 幕墙 － 大门 － 百叶 － 其他 PN-EN 1630","test_object_zh":"具有提高抗侵入性的建筑围护构件，其中包括：E － 窗 － 门 － 幕墙 － 大门 － 百叶 － 其他"},{"_id":"6a5a55f19af9f73f38250fa0","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Przegrody budowlane o podwyższonej odporności na włamanie w tym: E - okna - drzwi - ściany osłonowe - bramy - żaluzje - inne","test_object_en":"Building partitions with increased burglary resistance including: E - windows - doors - curtain walls - gates - shutters - others","methodology":"Odporność na obciążenia dynamiczne Zakres: grupa wyrobów 1 klasy 2 i 3","methodology_en":"Resistance to dynamic loads Range: product group 1 classes 2 and 3","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenia dynamiczne Zakres: grupa wyrobów 1 klasy 2 i 3","reference":"PN-EN 1629","norm_bases":["PN-EN 1629"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przegrody budowlane o podwyższonej odporności na włamanie w tym: E - okna - drzwi - ściany osłonowe - bramy - żaluzje - inne Odporność na obciążenia dynamiczne Zakres: grupa wyrobów 1 klasy 2 i 3 PN-EN 1629 Przegrody budowlane o podwyzszonej odpornosci na wlamanie w tym: E - okna - drzwi - sciany oslonowe - bramy - zaluzje - inne Odpornosc na obciazenia dynamiczne Zakres: grupa wyrobow 1 klasy 2 i 3 PN-EN 1629","categories":["construction"],"row_index":140,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building partitions with increased burglary resistance including: E - windows - doors - curtain walls - gates - shutters - others Resistance to dynamic loads Range: product group 1 classes 2 and 3 PN-EN 1629","search_zh":"具有提高抗侵入性的建筑围护构件，其中包括：E － 窗 － 门 － 幕墙 － 大门 － 百叶 － 其他 PN-EN 1629","test_object_zh":"具有提高抗侵入性的建筑围护构件，其中包括：E － 窗 － 门 － 幕墙 － 大门 － 百叶 － 其他"},{"_id":"6a5a55f19af9f73f38250fa1","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Przegrody budowlane o podwyższonej odporności na włamanie w tym: E - okna - drzwi - ściany osłonowe - bramy - żaluzje - inne","test_object_en":"Building partitions with increased burglary resistance including: E - windows - doors - curtain walls - gates - shutters - others","methodology":"Odporność na obciążenia statyczne Zakres: grupa wyrobów 1 klasy 2 i 3","methodology_en":"Resistance to static loads Range: product group 1 classes 2 and 3","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenia statyczne Zakres: grupa wyrobów 1 klasy 2 i 3","reference":"PN-EN 1628","norm_bases":["PN-EN 1628"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przegrody budowlane o podwyższonej odporności na włamanie w tym: E - okna - drzwi - ściany osłonowe - bramy - żaluzje - inne Odporność na obciążenia statyczne Zakres: grupa wyrobów 1 klasy 2 i 3 PN-EN 1628 Przegrody budowlane o podwyzszonej odpornosci na wlamanie w tym: E - okna - drzwi - sciany oslonowe - bramy - zaluzje - inne Odpornosc na obciazenia statyczne Zakres: grupa wyrobow 1 klasy 2 i 3 PN-EN 1628","categories":["construction"],"row_index":141,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building partitions with increased burglary resistance including: E - windows - doors - curtain walls - gates - shutters - others Resistance to static loads Range: product group 1 classes 2 and 3 PN-EN 1628","search_zh":"具有提高抗侵入性的建筑围护构件，其中包括：E － 窗 － 门 － 幕墙 － 大门 － 百叶 － 其他 PN-EN 1628","test_object_zh":"具有提高抗侵入性的建筑围护构件，其中包括：E － 窗 － 门 － 幕墙 － 大门 － 百叶 － 其他"},{"_id":"6a5a55f19af9f73f38250fa2","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Samonośne przepuszczające światło zestawy dachowe E","test_object_en":"Self-supporting translucent roof kits E","methodology":"Nośność na obciążenia odrywające i dociskające","methodology_en":"Load-bearing capacity under pull-off and compressive loads","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność na obciążenia odrywające i dociskające","reference":"EAD 220089-XX-0401","norm_bases":["EAD 220089-XX-0401"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Samonośne przepuszczające światło zestawy dachowe E Nośność na obciążenia odrywające i dociskające EAD 220089-XX-0401 Samonosne przepuszczajace swiatlo zestawy dachowe E Nosnosc na obciazenia odrywajace i dociskajace EAD 220089-XX-0401","categories":["construction"],"row_index":142,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Self-supporting translucent roof kits E Load-bearing capacity under pull-off and compressive loads EAD 220089-XX-0401","search_zh":"自承式透光屋面套件 E EAD 220089-XX-0401","test_object_zh":"自承式透光屋面套件 E"},{"_id":"6a5a55f19af9f73f38250fa3","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Samonośne przepuszczające światło zestawy dachowe E","test_object_en":"Self-supporting translucent roof kits E","methodology":"Odporność na uderzenie ciałem miękkim","methodology_en":"Soft body impact resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie ciałem miękkim","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Samonośne przepuszczające światło zestawy dachowe E Odporność na uderzenie ciałem miękkim Samonosne przepuszczajace swiatlo zestawy dachowe E Odpornosc na uderzenie cialem miekkim","categories":["construction"],"row_index":143,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Self-supporting translucent roof kits E Soft body impact resistance","search_zh":"自承式透光屋面套件 E","test_object_zh":"自承式透光屋面套件 E"},{"_id":"6a5a55f19af9f73f38250fa4","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Samonośne przepuszczające światło zestawy dachowe E","test_object_en":"Self-supporting translucent roof kits E","methodology":"Odporność na uderzenie ciałem twardym","methodology_en":"Resistance to hard body impact","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie ciałem twardym","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Samonośne przepuszczające światło zestawy dachowe E Odporność na uderzenie ciałem twardym Samonosne przepuszczajace swiatlo zestawy dachowe E Odpornosc na uderzenie cialem twardym","categories":["construction"],"row_index":144,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Self-supporting translucent roof kits E Resistance to hard body impact","methodology_zh":"硬物撞击抗力","search_zh":"自承式透光屋面套件 E 硬物撞击抗力","test_object_zh":"自承式透光屋面套件 E"},{"_id":"6a5a55f19af9f73f38250fa5","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Samonośne przepuszczające światło zestawy dachowe E","test_object_en":"Self-supporting translucent roof kits E","methodology":"Przepuszczalność powietrza","methodology_en":"Air permeability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność powietrza","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Samonośne przepuszczające światło zestawy dachowe E Przepuszczalność powietrza Samonosne przepuszczajace swiatlo zestawy dachowe E Przepuszczalnosc powietrza","categories":["construction"],"row_index":145,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Self-supporting translucent roof kits E Air permeability","methodology_zh":"透气性","search_zh":"自承式透光屋面套件 E 透气性","test_object_zh":"自承式透光屋面套件 E"},{"_id":"6a5a55f19af9f73f38250fa6","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Samonośne przepuszczające światło zestawy dachowe E","test_object_en":"Self-supporting translucent roof kits E","methodology":"Wodoszczelność","methodology_en":"Watertightness","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Samonośne przepuszczające światło zestawy dachowe E Wodoszczelność Samonosne przepuszczajace swiatlo zestawy dachowe E Wodoszczelnosc","categories":["construction"],"row_index":146,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Self-supporting translucent roof kits E Watertightness","methodology_zh":"不透水性","search_zh":"自承式透光屋面套件 E 不透水性","test_object_zh":"自承式透光屋面套件 E"},{"_id":"6a5a55f19af9f73f38250fa7","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stałe pionowe znaki drogowe Słupki prowadzące i urządzenia odblaskowe E","test_object_en":"Fixed vertical road signs Guide posts and retroreflective devices E","methodology":"Chromatyczność w świetle dziennym","methodology_en":"Chromaticity in daylight","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chromatyczność w świetle dziennym","reference":"PN-EN 12899-3 Raport techniczny CIE 15","norm_bases":["PN-EN 12899-3 Raport techniczny CIE 15"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stałe pionowe znaki drogowe Słupki prowadzące i urządzenia odblaskowe E Chromatyczność w świetle dziennym PN-EN 12899-3 Raport techniczny CIE 15 Stale pionowe znaki drogowe Slupki prowadzace i urzadzenia odblaskowe E Chromatycznosc w swietle dziennym PN-EN 12899-3 Raport techniczny CIE 15","categories":["other"],"row_index":147,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fixed vertical road signs Guide posts and retroreflective devices E Chromaticity in daylight PN-EN 12899-3 Raport techniczny CIE 15","search_zh":"固定式竖立道路标志 导向柱与反光装置 E PN-EN 12899-3 Raport techniczny CIE 15","test_object_zh":"固定式竖立道路标志 导向柱与反光装置 E"},{"_id":"6a5a55f19af9f73f38250fa8","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stałe pionowe znaki drogowe Słupki prowadzące i urządzenia odblaskowe E","test_object_en":"Fixed vertical road signs Guide posts and retroreflective devices E","methodology":"Odporność na wodę","methodology_en":"Water resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na wodę","reference":"PN-EN 12899-3","norm_bases":["PN-EN 12899-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stałe pionowe znaki drogowe Słupki prowadzące i urządzenia odblaskowe E Odporność na wodę PN-EN 12899-3 Stale pionowe znaki drogowe Slupki prowadzace i urzadzenia odblaskowe E Odpornosc na wode PN-EN 12899-3","categories":["other"],"row_index":148,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fixed vertical road signs Guide posts and retroreflective devices E Water resistance PN-EN 12899-3","search_zh":"固定式竖立道路标志 导向柱与反光装置 E PN-EN 12899-3","test_object_zh":"固定式竖立道路标志 导向柱与反光装置 E"},{"_id":"6a5a55f19af9f73f38250fa9","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stałe pionowe znaki drogowe Słupki prowadzące i urządzenia odblaskowe E","test_object_en":"Fixed vertical road signs Guide posts and retroreflective devices E","methodology":"Wytrzymałość statyczna (wytrzymałość na obciążenia poziome)","methodology_en":"Static strength (resistance to horizontal loads)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość statyczna (wytrzymałość na obciążenia poziome)","reference":"PN-EN 12899-3","norm_bases":["PN-EN 12899-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stałe pionowe znaki drogowe Słupki prowadzące i urządzenia odblaskowe E Wytrzymałość statyczna (wytrzymałość na obciążenia poziome) PN-EN 12899-3 Stale pionowe znaki drogowe Slupki prowadzace i urzadzenia odblaskowe E Wytrzymalosc statyczna (wytrzymalosc na obciazenia poziome) PN-EN 12899-3","categories":["other"],"row_index":149,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fixed vertical road signs Guide posts and retroreflective devices E Static strength (resistance to horizontal loads) PN-EN 12899-3","search_zh":"固定式竖立道路标志 导向柱与反光装置 E PN-EN 12899-3","test_object_zh":"固定式竖立道路标志 导向柱与反光装置 E"},{"_id":"6a5a55f19af9f73f38250faa","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stałe pionowe znaki drogowe Słupki prowadzące i urządzenia odblaskowe E","test_object_en":"Fixed vertical road signs Guide posts and retroreflective devices E","methodology":"Współczynnik luminancji","methodology_en":"Luminance factor","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Współczynnik luminancji","reference":"PN-EN 12899- 3 Raport techniczny CIE 15","norm_bases":["PN-EN 12899- 3 Raport techniczny CIE 15"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stałe pionowe znaki drogowe Słupki prowadzące i urządzenia odblaskowe E Współczynnik luminancji PN-EN 12899- 3 Raport techniczny CIE 15 Stale pionowe znaki drogowe Slupki prowadzace i urzadzenia odblaskowe E Wspolczynnik luminancji PN-EN 12899- 3 Raport techniczny CIE 15","categories":["other"],"row_index":150,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fixed vertical road signs Guide posts and retroreflective devices E Luminance factor PN-EN 12899- 3 Raport techniczny CIE 15","search_zh":"固定式竖立道路标志 导向柱与反光装置 E 亮度系数 PN-EN 12899- 3 Raport techniczny CIE 15","test_object_zh":"固定式竖立道路标志 导向柱与反光装置 E","methodology_zh":"亮度系数"},{"_id":"6a5a55f19af9f73f38250fab","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stałe pionowe znaki drogowe Słupki prowadzące i urządzenia odblaskowe E","test_object_en":"Fixed vertical road signs Guide posts and retroreflective devices E","methodology":"Współczynnik odblasku Zakres: 0-203 cd/m2lx α=20’ (0,33°), β=+5°, +30°, +40°","methodology_en":"Coefficient of retroreflection Range: 0-203 cd/m2lx α=20’ (0,33°), β=+5°, +30°, +40°","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Współczynnik odblasku Zakres: 0-203 cd/m2lx α=20’ (0,33°), β=+5°, +30°, +40°","reference":"PN-EN 12899-3 Raport techniczny CIE 54.2","norm_bases":["PN-EN 12899-3 Raport techniczny CIE 54.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stałe pionowe znaki drogowe Słupki prowadzące i urządzenia odblaskowe E Współczynnik odblasku Zakres: 0-203 cd/m2lx α=20’ (0,33°), β=+5°, +30°, +40° PN-EN 12899-3 Raport techniczny CIE 54.2 Stale pionowe znaki drogowe Slupki prowadzace i urzadzenia odblaskowe E Wspolczynnik odblasku Zakres: 0-203 cd/m2lx α=20’ (0,33°), β=+5°, +30°, +40° PN-EN 12899-3 Raport techniczny CIE 54.2","categories":["other"],"row_index":151,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fixed vertical road signs Guide posts and retroreflective devices E Coefficient of retroreflection Range: 0-203 cd/m2lx α=20’ (0,33°), β=+5°, +30°, +40° PN-EN 12899-3 Raport techniczny CIE 54.2","search_zh":"固定式竖立道路标志 导向柱与反光装置 E PN-EN 12899-3 Raport techniczny CIE 54.2","test_object_zh":"固定式竖立道路标志 导向柱与反光装置 E"},{"_id":"6a5a55f19af9f73f38250fac","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stałe pionowe znaki drogowe Słupki prowadzące i urządzenia odblaskowe E","test_object_en":"Fixed vertical road signs Guide posts and retroreflective devices E","methodology":"Wytrzymałość na uderzenie dynamiczne (badanie materiału)","methodology_en":"Resistance to dynamic impact (material test)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na uderzenie dynamiczne (badanie materiału)","reference":"PN-EN 12899-3","norm_bases":["PN-EN 12899-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stałe pionowe znaki drogowe Słupki prowadzące i urządzenia odblaskowe E Wytrzymałość na uderzenie dynamiczne (badanie materiału) PN-EN 12899-3 Stale pionowe znaki drogowe Slupki prowadzace i urzadzenia odblaskowe E Wytrzymalosc na uderzenie dynamiczne (badanie materialu) PN-EN 12899-3","categories":["materials"],"row_index":152,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fixed vertical road signs Guide posts and retroreflective devices E Resistance to dynamic impact (material test) PN-EN 12899-3","search_zh":"固定式竖立道路标志 导向柱与反光装置 E PN-EN 12899-3","test_object_zh":"固定式竖立道路标志 导向柱与反光装置 E"},{"_id":"6a5a55f19af9f73f38250fad","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stałe pionowe znaki drogowe Słupki prowadzące i urządzenia odblaskowe E","test_object_en":"Fixed vertical road signs Guide posts and retroreflective devices E","methodology":"Wytrzymałość na uderzenie dynamiczne (badanie funkcjonalne)","methodology_en":"Resistance to dynamic impact (functional test)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na uderzenie dynamiczne (badanie funkcjonalne)","reference":"PN-EN 12899-3","norm_bases":["PN-EN 12899-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stałe pionowe znaki drogowe Słupki prowadzące i urządzenia odblaskowe E Wytrzymałość na uderzenie dynamiczne (badanie funkcjonalne) PN-EN 12899-3 Stale pionowe znaki drogowe Slupki prowadzace i urzadzenia odblaskowe E Wytrzymalosc na uderzenie dynamiczne (badanie funkcjonalne) PN-EN 12899-3","categories":["other"],"row_index":153,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fixed vertical road signs Guide posts and retroreflective devices E Resistance to dynamic impact (functional test) PN-EN 12899-3","search_zh":"固定式竖立道路标志 导向柱与反光装置 E PN-EN 12899-3","test_object_zh":"固定式竖立道路标志 导向柱与反光装置 E"},{"_id":"6a5a55f19af9f73f38250fae","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stałe pionowe znaki drogowe Słupki prowadzące i urządzenia odblaskowe E","test_object_en":"Fixed vertical road signs Guide posts and retroreflective devices E","methodology":"Wytrzymałość na uderzenie dynamiczne urządzeń odblaskowych","methodology_en":"Resistance to dynamic impact of retro-reflecting devices","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na uderzenie dynamiczne urządzeń odblaskowych","reference":"PN-EN 12899-3","norm_bases":["PN-EN 12899-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stałe pionowe znaki drogowe Słupki prowadzące i urządzenia odblaskowe E Wytrzymałość na uderzenie dynamiczne urządzeń odblaskowych PN-EN 12899-3 Stale pionowe znaki drogowe Slupki prowadzace i urzadzenia odblaskowe E Wytrzymalosc na uderzenie dynamiczne urzadzen odblaskowych PN-EN 12899-3","categories":["other"],"row_index":154,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fixed vertical road signs Guide posts and retroreflective devices E Resistance to dynamic impact of retro-reflecting devices PN-EN 12899-3","search_zh":"固定式竖立道路标志 导向柱与反光装置 E PN-EN 12899-3","test_object_zh":"固定式竖立道路标志 导向柱与反光装置 E"},{"_id":"6a5a55f19af9f73f38250faf","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stałe pionowe znaki drogowe Znaki stałe E","test_object_en":"Fixed vertical road signs Fixed signs E","methodology":"Chromatyczność w świetle dziennym","methodology_en":"Chromaticity in daylight","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chromatyczność w świetle dziennym","reference":"PN-EN 12899-1 Raport techniczny CIE 15","norm_bases":["PN-EN 12899-1 Raport techniczny CIE 15"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stałe pionowe znaki drogowe Znaki stałe E Chromatyczność w świetle dziennym PN-EN 12899-1 Raport techniczny CIE 15 Stale pionowe znaki drogowe Znaki stale E Chromatycznosc w swietle dziennym PN-EN 12899-1 Raport techniczny CIE 15","categories":["other"],"row_index":155,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fixed vertical road signs Fixed signs E Chromaticity in daylight PN-EN 12899-1 Raport techniczny CIE 15"},{"_id":"6a5a55f19af9f73f38250fb0","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stałe pionowe znaki drogowe Znaki stałe E","test_object_en":"Fixed vertical road signs Fixed signs E","methodology":"Charakterystyka konstrukcji:  tymczasowe odkształcenie- zginanie i skręcanie  dynamiczne odkształcenie spowodowane zaśnieżeniem  odporność na działanie wiatru  odporność na obciążenie skupione  odkształcenie stałe  wytrzymałość mocowania Metoda badawcza Metoda obliczeniowa","methodology_en":"Characteristics of the structure:  temporary deformation - bending and torsion  dynamic deformation caused by snow load  resistance to wind action  resistance to point load  permanent deformation  strength of fixings Test method Calculation method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Charakterystyka konstrukcji:  tymczasowe odkształcenie- zginanie i skręcanie  dynamiczne odkształcenie spowodowane zaśnieżeniem  odporność na działanie wiatru  odporność na obciążenie skupione  odkształcenie stałe  wytrzymałość mocowania Metoda badawcza Metoda obliczeniowa","reference":"PN-EN 12899-1 PN-EN 12899-1 PB LK-144/1/04","norm_bases":["PN-EN 12899-1 PN-EN 12899-1 PB LK-144/1/04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stałe pionowe znaki drogowe Znaki stałe E Charakterystyka konstrukcji:  tymczasowe odkształcenie- zginanie i skręcanie  dynamiczne odkształcenie spowodowane zaśnieżeniem  odporność na działanie wiatru  odporność na obciążenie skupione  odkształcenie stałe  wytrzymałość mocowania Metoda badawcza Metoda obliczeniowa PN-EN 12899-1 PN-EN 12899-1 PB LK-144/1/04 Stale pionowe znaki drogowe Znaki stale E Charakterystyka konstrukcji:  tymczasowe odksztalcenie- zginanie i skrecanie  dynamiczne odksztalcenie spowodowane zasniezeniem  odpornosc na dzialanie wiatru  odpornosc na obciazenie skupione  odksztalcenie stale  wytrzymalosc mocowania Metoda badawcza Metoda obliczeniowa PN-EN 12899-1 PN-EN 12899-1 PB LK-144/1/04","categories":["other"],"row_index":156,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fixed vertical road signs Fixed signs E Characteristics of the structure:  temporary deformation - bending and torsion  dynamic deformation caused by snow load  resistance to wind action  resistance to point load  permanent deformation  strength of fixings Test method Calculation method PN-EN 12899-1 PN-EN 12899-1 PB LK-144/1/04"},{"_id":"6a5a55f19af9f73f38250fb1","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stałe pionowe znaki drogowe Słupki prowadzące i urządzenia odblaskowe E","test_object_en":"Fixed vertical road signs Guide posts and retroreflective devices E","methodology":"Wytrzymałość na uderzenie","methodology_en":"Impact strength","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na uderzenie","reference":"PN-EN 12899-1","norm_bases":["PN-EN 12899-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stałe pionowe znaki drogowe Słupki prowadzące i urządzenia odblaskowe E Wytrzymałość na uderzenie PN-EN 12899-1 Stale pionowe znaki drogowe Slupki prowadzace i urzadzenia odblaskowe E Wytrzymalosc na uderzenie PN-EN 12899-1","categories":["other"],"row_index":157,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fixed vertical road signs Guide posts and retroreflective devices E Impact strength PN-EN 12899-1","search_zh":"固定式竖立道路标志 导向柱与反光装置 E 抗冲击强度 PN-EN 12899-1","test_object_zh":"固定式竖立道路标志 导向柱与反光装置 E","methodology_zh":"抗冲击强度"},{"_id":"6a5a55f19af9f73f38250fb2","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stałe pionowe znaki drogowe Słupki prowadzące i urządzenia odblaskowe E","test_object_en":"Fixed vertical road signs Guide posts and retroreflective devices E","methodology":"Współczynnik luminancji","methodology_en":"Luminance factor","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Współczynnik luminancji","reference":"PN-EN 12899-1 Raport techniczny CIE 15","norm_bases":["PN-EN 12899-1 Raport techniczny CIE 15"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stałe pionowe znaki drogowe Słupki prowadzące i urządzenia odblaskowe E Współczynnik luminancji PN-EN 12899-1 Raport techniczny CIE 15 Stale pionowe znaki drogowe Slupki prowadzace i urzadzenia odblaskowe E Wspolczynnik luminancji PN-EN 12899-1 Raport techniczny CIE 15","categories":["other"],"row_index":158,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fixed vertical road signs Guide posts and retroreflective devices E Luminance factor PN-EN 12899-1 Raport techniczny CIE 15","search_zh":"固定式竖立道路标志 导向柱与反光装置 E 亮度系数 PN-EN 12899-1 Raport techniczny CIE 15","test_object_zh":"固定式竖立道路标志 导向柱与反光装置 E","methodology_zh":"亮度系数"},{"_id":"6a5a55f19af9f73f38250fb3","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stałe pionowe znaki drogowe Słupki prowadzące i urządzenia odblaskowe E","test_object_en":"Fixed vertical road signs Guide posts and retroreflective devices E","methodology":"Współczynnik odblasku Zakres: 0-203 cd/m2lx α=20’ (0,33°), β=+5°, +30°, +40°","methodology_en":"Coefficient of retroreflection Range: 0-203 cd/m2lx α=20’ (0,33°), β=+5°, +30°, +40°","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Współczynnik odblasku Zakres: 0-203 cd/m2lx α=20’ (0,33°), β=+5°, +30°, +40°","reference":"PN-EN 12899-1 Raport techniczny CIE 54.2","norm_bases":["PN-EN 12899-1 Raport techniczny CIE 54.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stałe pionowe znaki drogowe Słupki prowadzące i urządzenia odblaskowe E Współczynnik odblasku Zakres: 0-203 cd/m2lx α=20’ (0,33°), β=+5°, +30°, +40° PN-EN 12899-1 Raport techniczny CIE 54.2 Stale pionowe znaki drogowe Slupki prowadzace i urzadzenia odblaskowe E Wspolczynnik odblasku Zakres: 0-203 cd/m2lx α=20’ (0,33°), β=+5°, +30°, +40° PN-EN 12899-1 Raport techniczny CIE 54.2","categories":["other"],"row_index":159,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fixed vertical road signs Guide posts and retroreflective devices E Coefficient of retroreflection Range: 0-203 cd/m2lx α=20’ (0,33°), β=+5°, +30°, +40° PN-EN 12899-1 Raport techniczny CIE 54.2","search_zh":"固定式竖立道路标志 导向柱与反光装置 E PN-EN 12899-1 Raport techniczny CIE 54.2","test_object_zh":"固定式竖立道路标志 导向柱与反光装置 E"},{"_id":"6a5a55f19af9f73f38250fb4","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Sufity podwieszane E","test_object_en":"Suspended ceilings E","methodology":"Odporność na uderzenia","methodology_en":"Impact resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenia","reference":"PN-EN 13964 „N”","norm_bases":["PN-EN 13964 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Sufity podwieszane E Odporność na uderzenia PN-EN 13964 „N” Sufity podwieszane E Odpornosc na uderzenia PN-EN 13964 „N”","categories":["other"],"row_index":160,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Suspended ceilings E Impact resistance PN-EN 13964 „N”","methodology_zh":"耐冲击性","search_zh":"吊顶 E 耐冲击性 PN-EN 13964 „N”","test_object_zh":"吊顶 E"},{"_id":"6a5a55f19af9f73f38250fb5","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Systemy rynnowe z PVC E","test_object_en":"PVC gutter systems E","methodology":"Nośność uchwytów rur spustowych","methodology_en":"Load-bearing capacity of downpipe brackets","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność uchwytów rur spustowych","reference":"PN-EN 12095 PN-EN 12200-1","norm_bases":["PN-EN 12095 PN-EN 12200-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Systemy rynnowe z PVC E Nośność uchwytów rur spustowych PN-EN 12095 PN-EN 12200-1 Systemy rynnowe z PVC E Nosnosc uchwytow rur spustowych PN-EN 12095 PN-EN 12200-1","categories":["other"],"row_index":161,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"PVC gutter systems E Load-bearing capacity of downpipe brackets PN-EN 12095 PN-EN 12200-1"},{"_id":"6a5a55f19af9f73f38250fb6","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Systemy rynnowe z PVC E","test_object_en":"PVC gutter systems E","methodology":"Nośność uchwytów rynien","methodology_en":"Load-bearing capacity of gutter brackets","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność uchwytów rynien","reference":"PN-EN 1462","norm_bases":["PN-EN 1462"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Systemy rynnowe z PVC E Nośność uchwytów rynien PN-EN 1462 Systemy rynnowe z PVC E Nosnosc uchwytow rynien PN-EN 1462","categories":["other"],"row_index":162,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"PVC gutter systems E Load-bearing capacity of gutter brackets PN-EN 1462"},{"_id":"6a5a55f19af9f73f38250fb7","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Świetliki E - pasmowe - punktowe - inne Stałe pionowe znaki drogowe Znaki stałe","test_object_en":"Rooflights E - continuous - point - other Fixed vertical road signs Fixed signs","methodology":"Odporność na obciążenie dociskające","methodology_en":"Resistance to clamping load","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenie dociskające","reference":"PN-EN 14963 „N”","norm_bases":["PN-EN 14963 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Świetliki E - pasmowe - punktowe - inne Stałe pionowe znaki drogowe Znaki stałe Odporność na obciążenie dociskające PN-EN 14963 „N” Swietliki E - pasmowe - punktowe - inne Stale pionowe znaki drogowe Znaki stale Odpornosc na obciazenie dociskajace PN-EN 14963 „N”","categories":["other"],"row_index":163,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooflights E - continuous - point - other Fixed vertical road signs Fixed signs Resistance to clamping load PN-EN 14963 „N”","search_zh":"采光天窗 E － 带形 － 点式 － 其他 固定式竖立道路标志 固定标志 PN-EN 14963 „N”","test_object_zh":"采光天窗 E － 带形 － 点式 － 其他 固定式竖立道路标志 固定标志"},{"_id":"6a5a55f19af9f73f38250fb8","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Świetliki E - pasmowe - punktowe - inne Stałe pionowe znaki drogowe Znaki stałe","test_object_en":"Rooflights E - continuous - point - other Fixed vertical road signs Fixed signs","methodology":"Odporność na obciążenia działające od spodu","methodology_en":"Resistance to loads acting from below","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenia działające od spodu","reference":"PN-EN 1873 „N” EAD 220021-XX-0402","norm_bases":["PN-EN 1873 „N” EAD 220021-XX-0402"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Świetliki E - pasmowe - punktowe - inne Stałe pionowe znaki drogowe Znaki stałe Odporność na obciążenia działające od spodu PN-EN 1873 „N” EAD 220021-XX-0402 Swietliki E - pasmowe - punktowe - inne Stale pionowe znaki drogowe Znaki stale Odpornosc na obciazenia dzialajace od spodu PN-EN 1873 „N” EAD 220021-XX-0402","categories":["other"],"row_index":164,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooflights E - continuous - point - other Fixed vertical road signs Fixed signs Resistance to loads acting from below PN-EN 1873 „N” EAD 220021-XX-0402","search_zh":"采光天窗 E － 带形 － 点式 － 其他 固定式竖立道路标志 固定标志 PN-EN 1873 „N” EAD 220021-XX-0402","test_object_zh":"采光天窗 E － 带形 － 点式 － 其他 固定式竖立道路标志 固定标志"},{"_id":"6a5a55f19af9f73f38250fb9","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Świetliki E - pasmowe - punktowe - inne Stałe pionowe znaki drogowe Znaki stałe","test_object_en":"Rooflights E - continuous - point - other Fixed vertical road signs Fixed signs","methodology":"Odporność na obciążenia działające z góry","methodology_en":"Resistance to loads acting from above","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenia działające z góry","reference":"PN-EN 1873 „N” EAD 220021-XX-0402","norm_bases":["PN-EN 1873 „N” EAD 220021-XX-0402"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Świetliki E - pasmowe - punktowe - inne Stałe pionowe znaki drogowe Znaki stałe Odporność na obciążenia działające z góry PN-EN 1873 „N” EAD 220021-XX-0402 Swietliki E - pasmowe - punktowe - inne Stale pionowe znaki drogowe Znaki stale Odpornosc na obciazenia dzialajace z gory PN-EN 1873 „N” EAD 220021-XX-0402","categories":["other"],"row_index":165,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooflights E - continuous - point - other Fixed vertical road signs Fixed signs Resistance to loads acting from above PN-EN 1873 „N” EAD 220021-XX-0402","search_zh":"采光天窗 E － 带形 － 点式 － 其他 固定式竖立道路标志 固定标志 PN-EN 1873 „N” EAD 220021-XX-0402","test_object_zh":"采光天窗 E － 带形 － 点式 － 其他 固定式竖立道路标志 固定标志"},{"_id":"6a5a55f19af9f73f38250fba","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Świetliki E - pasmowe - punktowe - inne Stałe pionowe znaki drogowe Znaki stałe","test_object_en":"Rooflights E - continuous - point - other Fixed vertical road signs Fixed signs","methodology":"Odporność na obciążenie odrywające","methodology_en":"Resistance to peeling load","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenie odrywające","reference":"PN-EN 14963 „N”","norm_bases":["PN-EN 14963 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Świetliki E - pasmowe - punktowe - inne Stałe pionowe znaki drogowe Znaki stałe Odporność na obciążenie odrywające PN-EN 14963 „N” Swietliki E - pasmowe - punktowe - inne Stale pionowe znaki drogowe Znaki stale Odpornosc na obciazenie odrywajace PN-EN 14963 „N”","categories":["other"],"row_index":166,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooflights E - continuous - point - other Fixed vertical road signs Fixed signs Resistance to peeling load PN-EN 14963 „N”","search_zh":"采光天窗 E － 带形 － 点式 － 其他 固定式竖立道路标志 固定标志 PN-EN 14963 „N”","test_object_zh":"采光天窗 E － 带形 － 点式 － 其他 固定式竖立道路标志 固定标志"},{"_id":"6a5a55f19af9f73f38250fbb","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Świetliki E - pasmowe - punktowe - inne Stałe pionowe znaki drogowe Znaki stałe","test_object_en":"Rooflights E - continuous - point - other Fixed vertical road signs Fixed signs","methodology":"Odporność na uderzenie ciałem miękkim-ciężkim","methodology_en":"Soft-heavy body impact resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie ciałem miękkim-ciężkim","reference":"PN-EN 14963 „N” PN-EN 1873 EAD 220021-XX-0402","norm_bases":["PN-EN 14963 „N” PN-EN 1873 EAD 220021-XX-0402"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Świetliki E - pasmowe - punktowe - inne Stałe pionowe znaki drogowe Znaki stałe Odporność na uderzenie ciałem miękkim-ciężkim PN-EN 14963 „N” PN-EN 1873 EAD 220021-XX-0402 Swietliki E - pasmowe - punktowe - inne Stale pionowe znaki drogowe Znaki stale Odpornosc na uderzenie cialem miekkim-ciezkim PN-EN 14963 „N” PN-EN 1873 EAD 220021-XX-0402","categories":["other"],"row_index":167,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooflights E - continuous - point - other Fixed vertical road signs Fixed signs Soft-heavy body impact resistance PN-EN 14963 „N” PN-EN 1873 EAD 220021-XX-0402","search_zh":"采光天窗 E － 带形 － 点式 － 其他 固定式竖立道路标志 固定标志 PN-EN 14963 „N” PN-EN 1873 EAD 220021-XX-0402","test_object_zh":"采光天窗 E － 带形 － 点式 － 其他 固定式竖立道路标志 固定标志"},{"_id":"6a5a55f19af9f73f38250fbc","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Świetliki E - pasmowe - punktowe - inne Stałe pionowe znaki drogowe Znaki stałe","test_object_en":"Rooflights E - continuous - point - other Fixed vertical road signs Fixed signs","methodology":"Odporność na uderzenie ciałem twardym","methodology_en":"Resistance to hard body impact","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie ciałem twardym","reference":"PN-EN 14963 „N” PN-EN 1873 EAD 220021-XX-0402","norm_bases":["PN-EN 14963 „N” PN-EN 1873 EAD 220021-XX-0402"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Świetliki E - pasmowe - punktowe - inne Stałe pionowe znaki drogowe Znaki stałe Odporność na uderzenie ciałem twardym PN-EN 14963 „N” PN-EN 1873 EAD 220021-XX-0402 Swietliki E - pasmowe - punktowe - inne Stale pionowe znaki drogowe Znaki stale Odpornosc na uderzenie cialem twardym PN-EN 14963 „N” PN-EN 1873 EAD 220021-XX-0402","categories":["other"],"row_index":168,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooflights E - continuous - point - other Fixed vertical road signs Fixed signs Resistance to hard body impact PN-EN 14963 „N” PN-EN 1873 EAD 220021-XX-0402","methodology_zh":"硬物撞击抗力","search_zh":"采光天窗 E － 带形 － 点式 － 其他 固定式竖立道路标志 固定标志 硬物撞击抗力 PN-EN 14963 „N” PN-EN 1873 EAD 220021-XX-0402","test_object_zh":"采光天窗 E － 带形 － 点式 － 其他 固定式竖立道路标志 固定标志"},{"_id":"6a5a55f19af9f73f38250fbd","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Świetliki E - pasmowe - punktowe - inne Stałe pionowe znaki drogowe Znaki stałe","test_object_en":"Rooflights E - continuous - point - other Fixed vertical road signs Fixed signs","methodology":"Przepuszczalność powietrza +","methodology_en":"Air permeability +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność powietrza +","reference":"PN-EN 1026 „N” PN-EN 12153 EAD 220021-XX-0402","norm_bases":["PN-EN 1026 „N” PN-EN 12153 EAD 220021-XX-0402"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Świetliki E - pasmowe - punktowe - inne Stałe pionowe znaki drogowe Znaki stałe Przepuszczalność powietrza + PN-EN 1026 „N” PN-EN 12153 EAD 220021-XX-0402 Swietliki E - pasmowe - punktowe - inne Stale pionowe znaki drogowe Znaki stale Przepuszczalnosc powietrza + PN-EN 1026 „N” PN-EN 12153 EAD 220021-XX-0402","categories":["other"],"row_index":169,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooflights E - continuous - point - other Fixed vertical road signs Fixed signs Air permeability + PN-EN 1026 „N” PN-EN 12153 EAD 220021-XX-0402","methodology_zh":"透气性 +","search_zh":"采光天窗 E － 带形 － 点式 － 其他 固定式竖立道路标志 固定标志 透气性 + PN-EN 1026 „N” PN-EN 12153 EAD 220021-XX-0402","test_object_zh":"采光天窗 E － 带形 － 点式 － 其他 固定式竖立道路标志 固定标志"},{"_id":"6a5a55f19af9f73f38250fbe","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Świetliki E - pasmowe - punktowe - inne Stałe pionowe znaki drogowe Znaki stałe","test_object_en":"Rooflights E - continuous - point - other Fixed vertical road signs Fixed signs","methodology":"Wodoszczelność","methodology_en":"Watertightness","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność","reference":"PN-EN 14963 „N” PN-EN 1873 EAD 220021-XX-0402","norm_bases":["PN-EN 14963 „N” PN-EN 1873 EAD 220021-XX-0402"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Świetliki E - pasmowe - punktowe - inne Stałe pionowe znaki drogowe Znaki stałe Wodoszczelność PN-EN 14963 „N” PN-EN 1873 EAD 220021-XX-0402 Swietliki E - pasmowe - punktowe - inne Stale pionowe znaki drogowe Znaki stale Wodoszczelnosc PN-EN 14963 „N” PN-EN 1873 EAD 220021-XX-0402","categories":["other"],"row_index":170,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooflights E - continuous - point - other Fixed vertical road signs Fixed signs Watertightness PN-EN 14963 „N” PN-EN 1873 EAD 220021-XX-0402","methodology_zh":"不透水性","search_zh":"采光天窗 E － 带形 － 点式 － 其他 固定式竖立道路标志 固定标志 不透水性 PN-EN 14963 „N” PN-EN 1873 EAD 220021-XX-0402","test_object_zh":"采光天窗 E － 带形 － 点式 － 其他 固定式竖立道路标志 固定标志"},{"_id":"6a5a55f19af9f73f38250fbf","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby do uszczelnień połączeń okien ze ścianą E","test_object_en":"Products for sealing window-to-wall joints E","methodology":"Przepuszczalność powietrza","methodology_en":"Air permeability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność powietrza","reference":"PN-EN 1026","norm_bases":["PN-EN 1026"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby do uszczelnień połączeń okien ze ścianą E Przepuszczalność powietrza PN-EN 1026 Wyroby do uszczelnien polaczen okien ze sciana E Przepuszczalnosc powietrza PN-EN 1026","categories":["other"],"row_index":171,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Products for sealing window-to-wall joints E Air permeability PN-EN 1026","methodology_zh":"透气性","search_zh":"透气性 PN-EN 1026"},{"_id":"6a5a55f19af9f73f38250fc0","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby do uszczelnień połączeń okien ze ścianą E","test_object_en":"Products for sealing window-to-wall joints E","methodology":"Wodoszczelność","methodology_en":"Watertightness","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność","reference":"PN-EN 1027","norm_bases":["PN-EN 1027"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby do uszczelnień połączeń okien ze ścianą E Wodoszczelność PN-EN 1027 Wyroby do uszczelnien polaczen okien ze sciana E Wodoszczelnosc PN-EN 1027","categories":["other"],"row_index":172,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Products for sealing window-to-wall joints E Watertightness PN-EN 1027","methodology_zh":"不透水性","search_zh":"不透水性 PN-EN 1027"},{"_id":"6a5a55f19af9f73f38250fc1","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Szyby E","test_object_en":"Glass panes E","methodology":"Odporność na uderzenie Zakres: ciało o masie 50 kg","methodology_en":"Impact resistance Range: body with a mass of 50 kg","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie Zakres: ciało o masie 50 kg","reference":"PN-EN 12600 „N”","norm_bases":["PN-EN 12600 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Szyby E Odporność na uderzenie Zakres: ciało o masie 50 kg PN-EN 12600 „N” Szyby E Odpornosc na uderzenie Zakres: cialo o masie 50 kg PN-EN 12600 „N”","categories":["other"],"row_index":173,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Glass panes E Impact resistance Range: body with a mass of 50 kg PN-EN 12600 „N”"},{"_id":"6a5a55f19af9f73f38250fc2","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Szyby E","test_object_en":"Glass panes E","methodology":"Odporność szyb ochronnych na ręczny atak","methodology_en":"Resistance of protective glazing to manual attack","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność szyb ochronnych na ręczny atak","reference":"PN-EN 356 „N”","norm_bases":["PN-EN 356 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Szyby E Odporność szyb ochronnych na ręczny atak PN-EN 356 „N” Szyby E Odpornosc szyb ochronnych na reczny atak PN-EN 356 „N”","categories":["other"],"row_index":174,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Glass panes E Resistance of protective glazing to manual attack PN-EN 356 „N”"},{"_id":"6a5a55f19af9f73f38250fc3","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Ściany działowe E","test_object_en":"Partition walls E","methodology":"Wytrzymałość na obciążenie udarowe – bezpieczeństwo użytkowania Zakres: ciało udarowe do 50 kg Metoda uderzeniowa","methodology_en":"Resistance to impact load – safety in use Range: impact body up to 50 kg Impact method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na obciążenie udarowe – bezpieczeństwo użytkowania Zakres: ciało udarowe do 50 kg Metoda uderzeniowa","reference":"EAD 210005-XX-0505","norm_bases":["EAD 210005-XX-0505"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ściany działowe E Wytrzymałość na obciążenie udarowe – bezpieczeństwo użytkowania Zakres: ciało udarowe do 50 kg Metoda uderzeniowa EAD 210005-XX-0505 Sciany dzialowe E Wytrzymalosc na obciazenie udarowe – bezpieczenstwo uzytkowania Zakres: cialo udarowe do 50 kg Metoda uderzeniowa EAD 210005-XX-0505","categories":["other"],"row_index":175,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Partition walls E Resistance to impact load – safety in use Range: impact body up to 50 kg Impact method EAD 210005-XX-0505","search_zh":"隔墙 E EAD 210005-XX-0505","test_object_zh":"隔墙 E"},{"_id":"6a5a55f19af9f73f38250fc4","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Ściany działowe E","test_object_en":"Partition walls E","methodology":"Wytrzymałość na obciążenie udarowe – trwałość i przydatność użytkowa Zakres: ciało udarowe do 50 kg Metoda uderzeniowa","methodology_en":"Resistance to impact load – durability and serviceability Range: impact body up to 50 kg Impact method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na obciążenie udarowe – trwałość i przydatność użytkowa Zakres: ciało udarowe do 50 kg Metoda uderzeniowa","reference":"EAD 210005-XX-0505","norm_bases":["EAD 210005-XX-0505"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ściany działowe E Wytrzymałość na obciążenie udarowe – trwałość i przydatność użytkowa Zakres: ciało udarowe do 50 kg Metoda uderzeniowa EAD 210005-XX-0505 Sciany dzialowe E Wytrzymalosc na obciazenie udarowe – trwalosc i przydatnosc uzytkowa Zakres: cialo udarowe do 50 kg Metoda uderzeniowa EAD 210005-XX-0505","categories":["other"],"row_index":176,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Partition walls E Resistance to impact load – durability and serviceability Range: impact body up to 50 kg Impact method EAD 210005-XX-0505","search_zh":"隔墙 E EAD 210005-XX-0505","test_object_zh":"隔墙 E"},{"_id":"6a5a55f19af9f73f38250fc5","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Ściany działowe E","test_object_en":"Partition walls E","methodology":"Odporność na poziome liniowe obciążenie statyczne Zakres: siła do 10 kN/m, odkształcenia do 20 cm","methodology_en":"Resistance to horizontal linear static load Range: force up to 10 kN/m, deformation up to 20 cm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na poziome liniowe obciążenie statyczne Zakres: siła do 10 kN/m, odkształcenia do 20 cm","reference":"EAD 210005-XX-0505","norm_bases":["EAD 210005-XX-0505"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ściany działowe E Odporność na poziome liniowe obciążenie statyczne Zakres: siła do 10 kN/m, odkształcenia do 20 cm EAD 210005-XX-0505 Sciany dzialowe E Odpornosc na poziome liniowe obciazenie statyczne Zakres: sila do 10 kN/m, odksztalcenia do 20 cm EAD 210005-XX-0505","categories":["other"],"row_index":177,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Partition walls E Resistance to horizontal linear static load Range: force up to 10 kN/m, deformation up to 20 cm EAD 210005-XX-0505","search_zh":"隔墙 E EAD 210005-XX-0505","test_object_zh":"隔墙 E"},{"_id":"6a5a55f19af9f73f38250fc6","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zestawy okładzin wentylowanych i typu VETURE E","test_object_en":"Ventilated cladding kits and VETURE kits E","methodology":"Odporność na działanie zmiennej temperatury","methodology_en":"Resistance to varying temperature","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie zmiennej temperatury","reference":"EAD 090062-XX-0404","norm_bases":["EAD 090062-XX-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zestawy okładzin wentylowanych i typu VETURE E Odporność na działanie zmiennej temperatury EAD 090062-XX-0404 Zestawy okladzin wentylowanych i typu VETURE E Odpornosc na dzialanie zmiennej temperatury EAD 090062-XX-0404","categories":["other"],"row_index":178,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ventilated cladding kits and VETURE kits E Resistance to varying temperature EAD 090062-XX-0404","search_zh":"通风幕墙饰面系统与 VETURE 型系统 E EAD 090062-XX-0404","test_object_zh":"通风幕墙饰面系统与 VETURE 型系统 E"},{"_id":"6a5a55f19af9f73f38250fc7","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zestawy okładzin wentylowanych i typu VETURE E","test_object_en":"Ventilated cladding kits and VETURE kits E","methodology":"Odporność na działanie wiatru","methodology_en":"Resistance to wind","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie wiatru","reference":"EAD 090062-XX-0404 EAD 040914-XX-0404","norm_bases":["EAD 090062-XX-0404 EAD 040914-XX-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zestawy okładzin wentylowanych i typu VETURE E Odporność na działanie wiatru EAD 090062-XX-0404 EAD 040914-XX-0404 Zestawy okladzin wentylowanych i typu VETURE E Odpornosc na dzialanie wiatru EAD 090062-XX-0404 EAD 040914-XX-0404","categories":["other"],"row_index":179,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ventilated cladding kits and VETURE kits E Resistance to wind EAD 090062-XX-0404 EAD 040914-XX-0404","search_zh":"通风幕墙饰面系统与 VETURE 型系统 E EAD 090062-XX-0404 EAD 040914-XX-0404","test_object_zh":"通风幕墙饰面系统与 VETURE 型系统 E"},{"_id":"6a5a55f19af9f73f38250fc8","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zestawy okładzin wentylowanych i typu VETURE E","test_object_en":"Ventilated cladding kits and VETURE kits E","methodology":"Odporność na obciążenie siłą poziomą","methodology_en":"Resistance to horizontal force load","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenie siłą poziomą","reference":"EAD 090062-XX-0404 EAD 040914-XX-0404","norm_bases":["EAD 090062-XX-0404 EAD 040914-XX-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zestawy okładzin wentylowanych i typu VETURE E Odporność na obciążenie siłą poziomą EAD 090062-XX-0404 EAD 040914-XX-0404 Zestawy okladzin wentylowanych i typu VETURE E Odpornosc na obciazenie sila pozioma EAD 090062-XX-0404 EAD 040914-XX-0404","categories":["other"],"row_index":180,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ventilated cladding kits and VETURE kits E Resistance to horizontal force load EAD 090062-XX-0404 EAD 040914-XX-0404","search_zh":"通风幕墙饰面系统与 VETURE 型系统 E EAD 090062-XX-0404 EAD 040914-XX-0404","test_object_zh":"通风幕墙饰面系统与 VETURE 型系统 E"},{"_id":"6a5a55f19af9f73f38250fc9","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zestawy okładzin wentylowanych i typu VETURE E","test_object_en":"Ventilated cladding kits and VETURE kits E","methodology":"Odporność na obciążenie siłą pionową","methodology_en":"Resistance to vertical force load","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenie siłą pionową","reference":"EAD 090062-XX-0404 EAD 040914-XX-0404","norm_bases":["EAD 090062-XX-0404 EAD 040914-XX-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zestawy okładzin wentylowanych i typu VETURE E Odporność na obciążenie siłą pionową EAD 090062-XX-0404 EAD 040914-XX-0404 Zestawy okladzin wentylowanych i typu VETURE E Odpornosc na obciazenie sila pionowa EAD 090062-XX-0404 EAD 040914-XX-0404","categories":["other"],"row_index":181,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ventilated cladding kits and VETURE kits E Resistance to vertical force load EAD 090062-XX-0404 EAD 040914-XX-0404","search_zh":"通风幕墙饰面系统与 VETURE 型系统 E EAD 090062-XX-0404 EAD 040914-XX-0404","test_object_zh":"通风幕墙饰面系统与 VETURE 型系统 E"},{"_id":"6a5a55f19af9f73f38250fca","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zestawy okładzin wentylowanych i typu VETURE E","test_object_en":"Ventilated cladding kits and VETURE kits E","methodology":"Odporność na uderzenie ciałem miękkim i ciężkim","methodology_en":"Resistance to soft and heavy body impact","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie ciałem miękkim i ciężkim","reference":"EAD 090062-XX-0404 EAD 040914-XX-0404","norm_bases":["EAD 090062-XX-0404 EAD 040914-XX-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zestawy okładzin wentylowanych i typu VETURE E Odporność na uderzenie ciałem miękkim i ciężkim EAD 090062-XX-0404 EAD 040914-XX-0404 Zestawy okladzin wentylowanych i typu VETURE E Odpornosc na uderzenie cialem miekkim i ciezkim EAD 090062-XX-0404 EAD 040914-XX-0404","categories":["other"],"row_index":182,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ventilated cladding kits and VETURE kits E Resistance to soft and heavy body impact EAD 090062-XX-0404 EAD 040914-XX-0404","methodology_zh":"软体与硬重物撞击抗力","search_zh":"通风幕墙饰面系统与 VETURE 型系统 E 软体与硬重物撞击抗力 EAD 090062-XX-0404 EAD 040914-XX-0404","test_object_zh":"通风幕墙饰面系统与 VETURE 型系统 E"},{"_id":"6a5a55f19af9f73f38250fcb","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zestawy okładzin wentylowanych i typu VETURE E","test_object_en":"Ventilated cladding kits and VETURE kits E","methodology":"Odporność na uderzenie ciałem twardym","methodology_en":"Resistance to hard body impact","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie ciałem twardym","reference":"EAD 090062-XX-0404 EAD 040914-XX-0404","norm_bases":["EAD 090062-XX-0404 EAD 040914-XX-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zestawy okładzin wentylowanych i typu VETURE E Odporność na uderzenie ciałem twardym EAD 090062-XX-0404 EAD 040914-XX-0404 Zestawy okladzin wentylowanych i typu VETURE E Odpornosc na uderzenie cialem twardym EAD 090062-XX-0404 EAD 040914-XX-0404","categories":["other"],"row_index":183,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ventilated cladding kits and VETURE kits E Resistance to hard body impact EAD 090062-XX-0404 EAD 040914-XX-0404","methodology_zh":"硬物撞击抗力","search_zh":"通风幕墙饰面系统与 VETURE 型系统 E 硬物撞击抗力 EAD 090062-XX-0404 EAD 040914-XX-0404","test_object_zh":"通风幕墙饰面系统与 VETURE 型系统 E"},{"_id":"6a5a55f19af9f73f38250fcc","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Żaluzje E","test_object_en":"Blinds E","methodology":"Odporność na obciążenie wiatrem + Zakres: ciśnienie (–5000 - +5000) Pa","methodology_en":"Resistance to wind load + Range: pressure (–5000 - +5000) Pa","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenie wiatrem + Zakres: ciśnienie (–5000 - +5000) Pa","reference":"PN-EN 1932","norm_bases":["PN-EN 1932"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żaluzje E Odporność na obciążenie wiatrem + Zakres: ciśnienie (–5000 - +5000) Pa PN-EN 1932 Zaluzje E Odpornosc na obciazenie wiatrem + Zakres: cisnienie (–5000 - +5000) Pa PN-EN 1932","categories":["other"],"row_index":184,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Blinds E Resistance to wind load + Range: pressure (–5000 - +5000) Pa PN-EN 1932","search_zh":"百叶 E PN-EN 1932","test_object_zh":"百叶 E"},{"_id":"6a5a55f19af9f73f38250fcd","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Żaluzje E","test_object_en":"Blinds E","methodology":"Odporność na niewłaściwe użytkowanie","methodology_en":"Resistance to misuse","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na niewłaściwe użytkowanie","reference":"PN-EN 12194","norm_bases":["PN-EN 12194"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żaluzje E Odporność na niewłaściwe użytkowanie PN-EN 12194 Zaluzje E Odpornosc na niewlasciwe uzytkowanie PN-EN 12194","categories":["other"],"row_index":185,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Blinds E Resistance to misuse PN-EN 12194","search_zh":"百叶 E 误用的耐受性 PN-EN 12194","test_object_zh":"百叶 E","methodology_zh":"误用的耐受性"},{"_id":"6a5a55f19af9f73f38250fce","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Żaluzje E","test_object_en":"Blinds E","methodology":"Przepuszczalność powietrza +","methodology_en":"Air permeability +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność powietrza +","reference":"PN-EN 12835","norm_bases":["PN-EN 12835"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żaluzje E Przepuszczalność powietrza + PN-EN 12835 Zaluzje E Przepuszczalnosc powietrza + PN-EN 12835","categories":["other"],"row_index":186,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Blinds E Air permeability + PN-EN 12835","methodology_zh":"透气性 +","search_zh":"百叶 E 透气性 + PN-EN 12835","test_object_zh":"百叶 E"},{"_id":"6a5a55f19af9f73f38250fcf","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Żaluzje E","test_object_en":"Blinds E","methodology":"Siła operacyjna","methodology_en":"Operating force","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła operacyjna","reference":"PN-EN 13527","norm_bases":["PN-EN 13527"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żaluzje E Siła operacyjna PN-EN 13527 Zaluzje E Sila operacyjna PN-EN 13527","categories":["other"],"row_index":187,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Blinds E Operating force PN-EN 13527","search_zh":"百叶 E PN-EN 13527","test_object_zh":"百叶 E"},{"_id":"6a5a55f19af9f73f38250fd0","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Żaluzje E","test_object_en":"Blinds E","methodology":"Siła przenoszona","methodology_en":"Transmitted force","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła przenoszona","reference":"PN-EN 12045","norm_bases":["PN-EN 12045"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żaluzje E Siła przenoszona PN-EN 12045 Zaluzje E Sila przenoszona PN-EN 12045","categories":["other"],"row_index":188,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Blinds E Transmitted force PN-EN 12045","search_zh":"百叶 E PN-EN 12045","test_object_zh":"百叶 E"},{"_id":"6a5a55f19af9f73f38250fd1","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Żaluzje E","test_object_en":"Blinds E","methodology":"Uderzenie ciałem twardym","methodology_en":"Hard body impact","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Uderzenie ciałem twardym","reference":"PN-EN 13330","norm_bases":["PN-EN 13330"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żaluzje E Uderzenie ciałem twardym PN-EN 13330 Zaluzje E Uderzenie cialem twardym PN-EN 13330","categories":["other"],"row_index":189,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Blinds E Hard body impact PN-EN 13330","search_zh":"百叶 E PN-EN 13330","test_object_zh":"百叶 E"},{"_id":"6a5a55f19af9f73f38250fd2","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy szkieletowej konstrukcji stalowej E","test_object_en":"Components of steel framed structures E","methodology":"Charakterystyka geometryczna","methodology_en":"Geometrical characteristics","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Charakterystyka geometryczna","reference":"PN-EN 14195","norm_bases":["PN-EN 14195"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy szkieletowej konstrukcji stalowej E Charakterystyka geometryczna PN-EN 14195 Elementy szkieletowej konstrukcji stalowej E Charakterystyka geometryczna PN-EN 14195","categories":["materials"],"row_index":190,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Components of steel framed structures E Geometrical characteristics PN-EN 14195"},{"_id":"6a5a55f19af9f73f38250fd3","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy szkieletowej konstrukcji stalowej E","test_object_en":"Components of steel framed structures E","methodology":"Wymiary: grubość, długość, wymiar kątowy, prostość, szerokość środnika przekroju, szerokość półki, pomiar skręcania kształtownika","methodology_en":"Dimensions: thickness, length, angular dimension, straightness, web width of the section, flange width, measurement of twist of the section","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary: grubość, długość, wymiar kątowy, prostość, szerokość środnika przekroju, szerokość półki, pomiar skręcania kształtownika","reference":"PN-EN 14195","norm_bases":["PN-EN 14195"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy szkieletowej konstrukcji stalowej E Wymiary: grubość, długość, wymiar kątowy, prostość, szerokość środnika przekroju, szerokość półki, pomiar skręcania kształtownika PN-EN 14195 Elementy szkieletowej konstrukcji stalowej E Wymiary: grubosc, dlugosc, wymiar katowy, prostosc, szerokosc srodnika przekroju, szerokosc polki, pomiar skrecania ksztaltownika PN-EN 14195","categories":["materials"],"row_index":191,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Components of steel framed structures E Dimensions: thickness, length, angular dimension, straightness, web width of the section, flange width, measurement of twist of the section PN-EN 14195"},{"_id":"6a5a55f19af9f73f38250fd4","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zabudowy balkonów, loggii i tarasów E","test_object_en":"Balcony, loggia and terrace enclosures E","methodology":"Odporność na obciążenie wiatrem Zakres: ciśnienie od (-5000 - 5000) Pa Metoda obciążenia równomiernego","methodology_en":"Resistance to wind load Range: pressure from (-5000 - 5000) Pa Uniform load method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenie wiatrem Zakres: ciśnienie od (-5000 - 5000) Pa Metoda obciążenia równomiernego","reference":"LK-139 | XX-0404 | PN-EN 12211","norm_bases":["LK-139","XX-0404","PN-EN 12211"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zabudowy balkonów, loggii i tarasów E Odporność na obciążenie wiatrem Zakres: ciśnienie od (-5000 - 5000) Pa Metoda obciążenia równomiernego LK-139 | XX-0404 | PN-EN 12211 Zabudowy balkonow, loggii i tarasow E Odpornosc na obciazenie wiatrem Zakres: cisnienie od (-5000 - 5000) Pa Metoda obciazenia rownomiernego LK-139 | XX-0404 | PN-EN 12211","categories":["other"],"row_index":192,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Balcony, loggia and terrace enclosures E Resistance to wind load Range: pressure from (-5000 - 5000) Pa Uniform load method LK-139 | XX-0404 | PN-EN 12211","search_zh":"阳台、凉廊与露台封闭系统 E LK-139 | XX-0404 | PN-EN 12211","test_object_zh":"阳台、凉廊与露台封闭系统 E"},{"_id":"6a5a55f19af9f73f38250fd5","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zabudowy balkonów, loggii i tarasów E","test_object_en":"Balcony, loggia and terrace enclosures E","methodology":"Odporność na uderzenie ciałem miękkim i ciężkim Zakres: ciało o masie 50 kg Metoda udarnościowa","methodology_en":"Soft and heavy body impact resistance Range: body with a mass of 50 kg Impact method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie ciałem miękkim i ciężkim Zakres: ciało o masie 50 kg Metoda udarnościowa","reference":"LK-139 | XX-0404 | PN-EN 13049","norm_bases":["LK-139","XX-0404","PN-EN 13049"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zabudowy balkonów, loggii i tarasów E Odporność na uderzenie ciałem miękkim i ciężkim Zakres: ciało o masie 50 kg Metoda udarnościowa LK-139 | XX-0404 | PN-EN 13049 Zabudowy balkonow, loggii i tarasow E Odpornosc na uderzenie cialem miekkim i ciezkim Zakres: cialo o masie 50 kg Metoda udarnosciowa LK-139 | XX-0404 | PN-EN 13049","categories":["other"],"row_index":193,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Balcony, loggia and terrace enclosures E Soft and heavy body impact resistance Range: body with a mass of 50 kg Impact method LK-139 | XX-0404 | PN-EN 13049","search_zh":"阳台、凉廊与露台封闭系统 E LK-139 | XX-0404 | PN-EN 13049","test_object_zh":"阳台、凉廊与露台封闭系统 E"},{"_id":"6a5a55f19af9f73f38250fd6","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zabudowy balkonów, loggii i tarasów E","test_object_en":"Balcony, loggia and terrace enclosures E","methodology":"Odporność na obciążenie w płaszczyźnie skrzydła","methodology_en":"Resistance to load in the plane of the leaf","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenie w płaszczyźnie skrzydła","reference":"XX-0404 | PN-EN 14608","norm_bases":["XX-0404","PN-EN 14608"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zabudowy balkonów, loggii i tarasów E Odporność na obciążenie w płaszczyźnie skrzydła XX-0404 | PN-EN 14608 Zabudowy balkonow, loggii i tarasow E Odpornosc na obciazenie w plaszczyznie skrzydla XX-0404 | PN-EN 14608","categories":["other"],"row_index":194,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Balcony, loggia and terrace enclosures E Resistance to load in the plane of the leaf XX-0404 | PN-EN 14608","search_zh":"阳台、凉廊与露台封闭系统 E XX-0404 | PN-EN 14608","test_object_zh":"阳台、凉廊与露台封闭系统 E"},{"_id":"6a5a55f19af9f73f38250fd7","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zabudowy balkonów, loggii i tarasów E","test_object_en":"Balcony, loggia and terrace enclosures E","methodology":"Odporność na skręcanie statyczne","methodology_en":"Resistance to static torsion","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na skręcanie statyczne","reference":"XX-0404 | PN-EN 14609","norm_bases":["XX-0404","PN-EN 14609"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zabudowy balkonów, loggii i tarasów E Odporność na skręcanie statyczne XX-0404 | PN-EN 14609 Zabudowy balkonow, loggii i tarasow E Odpornosc na skrecanie statyczne XX-0404 | PN-EN 14609","categories":["other"],"row_index":195,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Balcony, loggia and terrace enclosures E Resistance to static torsion XX-0404 | PN-EN 14609","search_zh":"阳台、凉廊与露台封闭系统 E XX-0404 | PN-EN 14609","test_object_zh":"阳台、凉廊与露台封闭系统 E"},{"_id":"6a5a55f19af9f73f38250fd8","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zabudowy balkonów, loggii i tarasów E","test_object_en":"Balcony, loggia and terrace enclosures E","methodology":"Odporność wielokrotne otwieranie i zamykanie Metoda ręcznej manipulacji","methodology_en":"Resistance to repeated opening and closing Manual manipulation method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność wielokrotne otwieranie i zamykanie Metoda ręcznej manipulacji","reference":"LK-139","norm_bases":["LK-139"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zabudowy balkonów, loggii i tarasów E Odporność wielokrotne otwieranie i zamykanie Metoda ręcznej manipulacji LK-139 Zabudowy balkonow, loggii i tarasow E Odpornosc wielokrotne otwieranie i zamykanie Metoda recznej manipulacji LK-139","categories":["other"],"row_index":196,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Balcony, loggia and terrace enclosures E Resistance to repeated opening and closing Manual manipulation method LK-139","search_zh":"阳台、凉廊与露台封闭系统 E LK-139","test_object_zh":"阳台、凉廊与露台封闭系统 E"},{"_id":"6a5a55f19af9f73f38250fd9","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zabudowy balkonów, loggii i tarasów E","test_object_en":"Balcony, loggia and terrace enclosures E","methodology":"Siły operacyjne","methodology_en":"Operating forces","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siły operacyjne","reference":"LK-139","norm_bases":["LK-139"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zabudowy balkonów, loggii i tarasów E Siły operacyjne LK-139 Zabudowy balkonow, loggii i tarasow E Sily operacyjne LK-139","categories":["other"],"row_index":197,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Balcony, loggia and terrace enclosures E Operating forces LK-139","methodology_zh":"操作力","search_zh":"阳台、凉廊与露台封闭系统 E 操作力 LK-139","test_object_zh":"阳台、凉廊与露台封闭系统 E"},{"_id":"6a5a55f19af9f73f38250fda","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Bramy E","test_object_en":"Gates E","methodology":"Trwałość samoczynnego zamykania","methodology_en":"Durability of self-closing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość samoczynnego zamykania","reference":"PN-EN 16034","norm_bases":["PN-EN 16034"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bramy E Trwałość samoczynnego zamykania PN-EN 16034 Bramy E Trwalosc samoczynnego zamykania PN-EN 16034","categories":["other"],"row_index":198,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gates E Durability of self-closing PN-EN 16034","search_zh":"大门 E 自闭合耐久性 PN-EN 16034","test_object_zh":"大门 E","methodology_zh":"自闭合耐久性"},{"_id":"6a5a55f19af9f73f38250fdb","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Odporność na obciążenia pionowe","methodology_en":"Resistance to vertical loads","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenia pionowe","reference":"PN-EN 947","norm_bases":["PN-EN 947"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odporność na obciążenia pionowe PN-EN 947 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odpornosc na obciazenia pionowe PN-EN 947","categories":["other"],"row_index":199,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Resistance to vertical loads PN-EN 947","search_zh":"门、门组件、门扇、门框 E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道 PN-EN 947","test_object_zh":"门、门组件、门扇、门框 E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道"},{"_id":"6a5a55f19af9f73f38250fdc","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Odporność na wielokrotne otwieranie i zamykanie Metoda automatyczna","methodology_en":"Resistance to repeated opening and closing Automatic method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na wielokrotne otwieranie i zamykanie Metoda automatyczna","reference":"PN-EN 1191","norm_bases":["PN-EN 1191"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odporność na wielokrotne otwieranie i zamykanie Metoda automatyczna PN-EN 1191 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odpornosc na wielokrotne otwieranie i zamykanie Metoda automatyczna PN-EN 1191","categories":["other"],"row_index":200,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Resistance to repeated opening and closing Automatic method PN-EN 1191","search_zh":"门、门组件、门扇、门框 E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道 PN-EN 1191","test_object_zh":"门、门组件、门扇、门框 E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道"},{"_id":"6a5a55f19af9f73f38250fdd","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Odporność na obciążenie wiatrem + Zakres ciśnień: (–5000 - +5000) Pa","methodology_en":"Resistance to wind load + Pressure range: (–5000 - +5000) Pa","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenie wiatrem + Zakres ciśnień: (–5000 - +5000) Pa","reference":"PN-EN 12211 „N’’ PN-EN 16361","norm_bases":["PN-EN 12211 „N’’ PN-EN 16361"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odporność na obciążenie wiatrem + Zakres ciśnień: (–5000 - +5000) Pa PN-EN 12211 „N’’ PN-EN 16361 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odpornosc na obciazenie wiatrem + Zakres cisnien: (–5000 - +5000) Pa PN-EN 12211 „N’’ PN-EN 16361","categories":["other"],"row_index":201,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Resistance to wind load + Pressure range: (–5000 - +5000) Pa PN-EN 12211 „N’’ PN-EN 16361","search_zh":"门、门组件、门扇、门框 E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道 PN-EN 12211 „N’’ PN-EN 16361","test_object_zh":"门、门组件、门扇、门框 E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道"},{"_id":"6a5a55f19af9f73f38250fde","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Odporność na uderzenie ciałem miękkim i ciężkim Zakres: ciało o masie 50 kg","methodology_en":"Resistance to soft and heavy body impact Range: body of 50 kg mass","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie ciałem miękkim i ciężkim Zakres: ciało o masie 50 kg","reference":"PN-EN 16361","norm_bases":["PN-EN 16361"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odporność na uderzenie ciałem miękkim i ciężkim Zakres: ciało o masie 50 kg PN-EN 16361 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odpornosc na uderzenie cialem miekkim i ciezkim Zakres: cialo o masie 50 kg PN-EN 16361","categories":["other"],"row_index":202,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Resistance to soft and heavy body impact Range: body of 50 kg mass PN-EN 16361","search_zh":"门、门组件、门扇、门框 E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道 PN-EN 16361","test_object_zh":"门、门组件、门扇、门框 E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道"},{"_id":"6a5a55f19af9f73f38250fdf","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Odporność na uderzenie ciałem miękkim i ciężkim Zakres: ciało o masie 50 kg","methodology_en":"Resistance to soft and heavy body impact Range: body of 50 kg mass","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie ciałem miękkim i ciężkim Zakres: ciało o masie 50 kg","reference":"PN-EN 14351-2 PN-EN 13049 + PN-EN 12600","norm_bases":["PN-EN 14351-2 PN-EN 13049 + PN-EN 12600"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odporność na uderzenie ciałem miękkim i ciężkim Zakres: ciało o masie 50 kg PN-EN 14351-2 PN-EN 13049 + PN-EN 12600 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Odpornosc na uderzenie cialem miekkim i ciezkim Zakres: cialo o masie 50 kg PN-EN 14351-2 PN-EN 13049 + PN-EN 12600","categories":["other"],"row_index":203,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Resistance to soft and heavy body impact Range: body of 50 kg mass PN-EN 14351-2 PN-EN 13049 + PN-EN 12600","search_zh":"门、门组件、门扇、门框 E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道 PN-EN 14351-2 PN-EN 13049 + PN-EN 12600","test_object_zh":"门、门组件、门扇、门框 E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道"},{"_id":"6a5a55f19af9f73f38250fe0","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Przepuszczalność powietrza","methodology_en":"Air permeability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność powietrza","reference":"PN-EN 1026 „N’’ PN-EN 16361 PN-EN 14351-2","norm_bases":["PN-EN 1026 „N’’ PN-EN 16361 PN-EN 14351-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Przepuszczalność powietrza PN-EN 1026 „N’’ PN-EN 16361 PN-EN 14351-2 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Przepuszczalnosc powietrza PN-EN 1026 „N’’ PN-EN 16361 PN-EN 14351-2","categories":["other"],"row_index":204,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Air permeability PN-EN 1026 „N’’ PN-EN 16361 PN-EN 14351-2","methodology_zh":"透气性","search_zh":"门、门组件、门扇、门框 E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道 透气性 PN-EN 1026 „N’’ PN-EN 16361 PN-EN 14351-2","test_object_zh":"门、门组件、门扇、门框 E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道"},{"_id":"6a5a55f19af9f73f38250fe1","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Samoczynne zamykanie","methodology_en":"Self-closing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Samoczynne zamykanie","reference":"PN-EN 16034","norm_bases":["PN-EN 16034"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Samoczynne zamykanie PN-EN 16034 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Samoczynne zamykanie PN-EN 16034","categories":["other"],"row_index":205,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Self-closing PN-EN 16034","search_zh":"门、门组件、门扇、门框 E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道 自闭合 PN-EN 16034","test_object_zh":"门、门组件、门扇、门框 E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道","methodology_zh":"自闭合"},{"_id":"6a5a55f19af9f73f38250fe2","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Siły operacyjne","methodology_en":"Operating forces","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siły operacyjne","reference":"PN-EN 12046-2 PN-EN 16361","norm_bases":["PN-EN 12046-2 PN-EN 16361"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Siły operacyjne PN-EN 12046-2 PN-EN 16361 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Sily operacyjne PN-EN 12046-2 PN-EN 16361","categories":["other"],"row_index":206,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Operating forces PN-EN 12046-2 PN-EN 16361","search_zh":"门、门组件、门扇、门框 E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道 操作力 PN-EN 12046-2 PN-EN 16361","test_object_zh":"门、门组件、门扇、门框 E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道","methodology_zh":"操作力"},{"_id":"6a5a55f19af9f73f38250fe3","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Trwałość samoczynnego zamykania","methodology_en":"Durability of self-closing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość samoczynnego zamykania","reference":"PN-EN 16034","norm_bases":["PN-EN 16034"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Trwałość samoczynnego zamykania PN-EN 16034 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Trwalosc samoczynnego zamykania PN-EN 16034","categories":["other"],"row_index":207,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Durability of self-closing PN-EN 16034","search_zh":"门、门组件、门扇、门框 E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道 自闭合耐久性 PN-EN 16034","test_object_zh":"门、门组件、门扇、门框 E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道","methodology_zh":"自闭合耐久性"},{"_id":"6a5a55f19af9f73f38250fe4","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Wymiary liniowe ościeżnic Metoda pomiaru liniowego","methodology_en":"Linear dimensions of door frames Linear measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary liniowe ościeżnic Metoda pomiaru liniowego","reference":"PN-EN 16361","norm_bases":["PN-EN 16361"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wymiary liniowe ościeżnic Metoda pomiaru liniowego PN-EN 16361 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wymiary liniowe oscieznic Metoda pomiaru liniowego PN-EN 16361","categories":["other"],"row_index":208,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Linear dimensions of door frames Linear measurement method PN-EN 16361","search_zh":"门、门组件、门扇、门框 E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道 PN-EN 16361","test_object_zh":"门、门组件、门扇、门框 E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道"},{"_id":"6a5a55f19af9f73f38250fe5","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Wodoszczelność","methodology_en":"Watertightness","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność","reference":"PN-EN 1027 „N’’ PN-EN 16361","norm_bases":["PN-EN 1027 „N’’ PN-EN 16361"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wodoszczelność PN-EN 1027 „N’’ PN-EN 16361 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wodoszczelnosc PN-EN 1027 „N’’ PN-EN 16361","categories":["other"],"row_index":209,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Watertightness PN-EN 1027 „N’’ PN-EN 16361","methodology_zh":"不透水性","search_zh":"门、门组件、门扇、门框 E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道 不透水性 PN-EN 1027 „N’’ PN-EN 16361","test_object_zh":"门、门组件、门扇、门框 E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道"},{"_id":"6a5a55f19af9f73f38250fe6","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Wysokość i szerokość","methodology_en":"Height and width","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wysokość i szerokość","reference":"PN-EN 16361","norm_bases":["PN-EN 16361"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wysokość i szerokość PN-EN 16361 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wysokosc i szerokosc PN-EN 16361","categories":["other"],"row_index":210,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Height and width PN-EN 16361","search_zh":"门、门组件、门扇、门框 E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道 PN-EN 16361","test_object_zh":"门、门组件、门扇、门框 E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道"},{"_id":"6a5a55f19af9f73f38250fe7","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Wysokość","methodology_en":"Height","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wysokość","reference":"PN-EN 14351-2","norm_bases":["PN-EN 14351-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wysokość PN-EN 14351-2 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wysokosc PN-EN 14351-2","categories":["other"],"row_index":211,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Height PN-EN 14351-2","search_zh":"门、门组件、门扇、门框 E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道 高度 PN-EN 14351-2","test_object_zh":"门、门组件、门扇、门框 E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道","methodology_zh":"高度"},{"_id":"6a5a55f19af9f73f38250fe8","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Szerokość","methodology_en":"Width","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szerokość","reference":"PN-EN 14351-2","norm_bases":["PN-EN 14351-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Szerokość PN-EN 14351-2 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Szerokosc PN-EN 14351-2","categories":["other"],"row_index":212,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Width PN-EN 14351-2","methodology_zh":"宽度","search_zh":"门、门组件、门扇、门框 E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道 宽度 PN-EN 14351-2","test_object_zh":"门、门组件、门扇、门框 E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道"},{"_id":"6a5a55f19af9f73f38250fe9","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Wytrzymałość na skręcanie statyczne","methodology_en":"Static torsional strength","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na skręcanie statyczne","reference":"PN-EN 948","norm_bases":["PN-EN 948"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wytrzymałość na skręcanie statyczne PN-EN 948 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Wytrzymalosc na skrecanie statyczne PN-EN 948","categories":["other"],"row_index":213,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Static torsional strength PN-EN 948","search_zh":"门、门组件、门扇、门框 E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道 静态抗扭强度 PN-EN 948","test_object_zh":"门、门组件、门扇、门框 E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道","methodology_zh":"静态抗扭强度"},{"_id":"6a5a55f19af9f73f38250fea","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Zdolność do zwolnienia","methodology_en":"Release capability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność do zwolnienia","reference":"PN-EN 1125 PN-EN 179 PN-EN 14351-2","norm_bases":["PN-EN 1125 PN-EN 179 PN-EN 14351-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - ognioodporne - dymoszczelne - uruchamianych ręcznie i z napędami - z okuciami antypanicznymi - na drogach ewakuacyjnych Zdolność do zwolnienia PN-EN 1125 PN-EN 179 PN-EN 14351-2 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - ognioodporne - dymoszczelne - uruchamianych recznie i z napedami - z okuciami antypanicznymi - na drogach ewakuacyjnych Zdolnosc do zwolnienia PN-EN 1125 PN-EN 179 PN-EN 14351-2","categories":["other"],"row_index":214,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - fire resistant - smoke tight - manually operated and power operated - with panic exit devices - on escape routes Release capability PN-EN 1125 PN-EN 179 PN-EN 14351-2","search_zh":"门、门组件、门扇、门框 E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道 释放能力 PN-EN 1125 PN-EN 179 PN-EN 14351-2","test_object_zh":"门、门组件、门扇、门框 E － 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 耐火 － 防烟 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道","methodology_zh":"释放能力"},{"_id":"6a5a55f19af9f73f38250feb","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna E","test_object_en":"Windows E","methodology":"Nośność urządzeń zabezpieczających","methodology_en":"Load-bearing capacity of safety devices","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność urządzeń zabezpieczających","reference":"PN-EN 14351-1 „N’’","norm_bases":["PN-EN 14351-1 „N’’"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna E Nośność urządzeń zabezpieczających PN-EN 14351-1 „N’’ Okna E Nosnosc urzadzen zabezpieczajacych PN-EN 14351-1 „N’’","categories":["other"],"row_index":215,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows E Load-bearing capacity of safety devices PN-EN 14351-1 „N’’","search_zh":"窗 E 安全装置的承载力 PN-EN 14351-1 „N’’","test_object_zh":"窗 E","methodology_zh":"安全装置的承载力"},{"_id":"6a5a55f19af9f73f38250fec","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna E","test_object_en":"Windows E","methodology":"Odporność na obciążenie wiatrem Zakres ciśnień: (–5000 - +5000) Pa","methodology_en":"Resistance to wind load Pressure range: (–5000 - +5000) Pa","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenie wiatrem Zakres ciśnień: (–5000 - +5000) Pa","reference":"PN-EN 12211 „N’’","norm_bases":["PN-EN 12211 „N’’"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna E Odporność na obciążenie wiatrem Zakres ciśnień: (–5000 - +5000) Pa PN-EN 12211 „N’’ Okna E Odpornosc na obciazenie wiatrem Zakres cisnien: (–5000 - +5000) Pa PN-EN 12211 „N’’","categories":["other"],"row_index":216,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows E Resistance to wind load Pressure range: (–5000 - +5000) Pa PN-EN 12211 „N’’","search_zh":"窗 E PN-EN 12211 „N’’","test_object_zh":"窗 E"},{"_id":"6a5a55f19af9f73f38250fed","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna E","test_object_en":"Windows E","methodology":"Przepuszczalność powietrza","methodology_en":"Air permeability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność powietrza","reference":"PN-EN 1026 „N’’","norm_bases":["PN-EN 1026 „N’’"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna E Przepuszczalność powietrza PN-EN 1026 „N’’ Okna E Przepuszczalnosc powietrza PN-EN 1026 „N’’","categories":["other"],"row_index":217,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows E Air permeability PN-EN 1026 „N’’","methodology_zh":"透气性","search_zh":"窗 E 透气性 PN-EN 1026 „N’’","test_object_zh":"窗 E"},{"_id":"6a5a55f19af9f73f38250fee","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna E","test_object_en":"Windows E","methodology":"Siły operacyjne","methodology_en":"Operating forces","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siły operacyjne","reference":"PN-EN 12046-1","norm_bases":["PN-EN 12046-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna E Siły operacyjne PN-EN 12046-1 Okna E Sily operacyjne PN-EN 12046-1","categories":["other"],"row_index":218,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows E Operating forces PN-EN 12046-1","methodology_zh":"操作力","search_zh":"窗 E 操作力 PN-EN 12046-1","test_object_zh":"窗 E"},{"_id":"6a5a55f19af9f73f38250fef","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna E","test_object_en":"Windows E","methodology":"Wodoszczelność Ciśnienie do 5000 Pa","methodology_en":"Watertightness Pressure up to 5000 Pa","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność Ciśnienie do 5000 Pa","reference":"PN-EN 1027 „N’’","norm_bases":["PN-EN 1027 „N’’"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna E Wodoszczelność Ciśnienie do 5000 Pa PN-EN 1027 „N’’ Okna E Wodoszczelnosc Cisnienie do 5000 Pa PN-EN 1027 „N’’","categories":["other"],"row_index":219,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows E Watertightness Pressure up to 5000 Pa PN-EN 1027 „N’’","search_zh":"窗 E PN-EN 1027 „N’’","test_object_zh":"窗 E"},{"_id":"6a5a55f19af9f73f38250ff0","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Balustrady i poręcze budowlane","test_object_en":"Building balustrades and handrails","methodology":"Odporność na uderzenie ciałem miękkim i ciężkim ciało udarowe – worek 30 kg","methodology_en":"Soft and heavy body impact resistance impact body – bag 30 kg","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie ciałem miękkim i ciężkim ciało udarowe – worek 30 kg","reference":"LZE-140/2/04-2019","norm_bases":["LZE-140/2/04-2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Balustrady i poręcze budowlane Odporność na uderzenie ciałem miękkim i ciężkim ciało udarowe – worek 30 kg LZE-140/2/04-2019 Balustrady i porecze budowlane Odpornosc na uderzenie cialem miekkim i ciezkim cialo udarowe – worek 30 kg LZE-140/2/04-2019","categories":["construction"],"row_index":220,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building balustrades and handrails Soft and heavy body impact resistance impact body – bag 30 kg LZE-140/2/04-2019","search_zh":"建筑栏杆与扶手 LZE-140/2/04-2019","test_object_zh":"建筑栏杆与扶手"},{"_id":"6a5a55f19af9f73f38250ff1","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Balustrady i poręcze budowlane","test_object_en":"Building balustrades and handrails","methodology":"Odporność na uderzenie ciałem miękkim i ciężkim ciało udarowe – opona 50 kg","methodology_en":"Soft and heavy body impact resistance impact body – tyre 50 kg","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie ciałem miękkim i ciężkim ciało udarowe – opona 50 kg","reference":"LZE-140/2/04-2019","norm_bases":["LZE-140/2/04-2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Balustrady i poręcze budowlane Odporność na uderzenie ciałem miękkim i ciężkim ciało udarowe – opona 50 kg LZE-140/2/04-2019 Balustrady i porecze budowlane Odpornosc na uderzenie cialem miekkim i ciezkim cialo udarowe – opona 50 kg LZE-140/2/04-2019","categories":["construction"],"row_index":221,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building balustrades and handrails Soft and heavy body impact resistance impact body – tyre 50 kg LZE-140/2/04-2019","search_zh":"建筑栏杆与扶手 LZE-140/2/04-2019","test_object_zh":"建筑栏杆与扶手"},{"_id":"6a5a55f19af9f73f38250ff2","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Balustrady i poręcze budowlane","test_object_en":"Building balustrades and handrails","methodology":"Wytrzymałość na obciążenia statyczne Zakres: obciążenie do 3 kN/m","methodology_en":"Resistance to static loads Range: load up to 3 kN/m","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na obciążenia statyczne Zakres: obciążenie do 3 kN/m","reference":"LZE-140/2/04-2019","norm_bases":["LZE-140/2/04-2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Balustrady i poręcze budowlane Wytrzymałość na obciążenia statyczne Zakres: obciążenie do 3 kN/m LZE-140/2/04-2019 Balustrady i porecze budowlane Wytrzymalosc na obciazenia statyczne Zakres: obciazenie do 3 kN/m LZE-140/2/04-2019","categories":["construction"],"row_index":222,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building balustrades and handrails Resistance to static loads Range: load up to 3 kN/m LZE-140/2/04-2019","search_zh":"建筑栏杆与扶手 LZE-140/2/04-2019","test_object_zh":"建筑栏杆与扶手"},{"_id":"6a5a55f19af9f73f38250ff3","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Balustrady i poręcze budowlane","test_object_en":"Building balustrades and handrails","methodology":"Odporność na uderzenie ciałem twardym ciało udarowe - kula stalowa 0,5 kg","methodology_en":"Hard body impact resistance impact body - steel ball 0,5 kg","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie ciałem twardym ciało udarowe - kula stalowa 0,5 kg","reference":"LZE-140/2/04-2019","norm_bases":["LZE-140/2/04-2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Balustrady i poręcze budowlane Odporność na uderzenie ciałem twardym ciało udarowe - kula stalowa 0,5 kg LZE-140/2/04-2019 Balustrady i porecze budowlane Odpornosc na uderzenie cialem twardym cialo udarowe - kula stalowa 0,5 kg LZE-140/2/04-2019","categories":["materials","construction"],"row_index":223,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building balustrades and handrails Hard body impact resistance impact body - steel ball 0,5 kg LZE-140/2/04-2019","search_zh":"建筑栏杆与扶手 LZE-140/2/04-2019","test_object_zh":"建筑栏杆与扶手"},{"_id":"6a5a55f19af9f73f38250ff4","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Bramy","test_object_en":"Gates","methodology":"Samoczynne zamykanie","methodology_en":"Self-closing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Samoczynne zamykanie","reference":"PN-EN 16034:2014","norm_bases":["PN-EN 16034:2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bramy Samoczynne zamykanie PN-EN 16034:2014 Bramy Samoczynne zamykanie PN-EN 16034:2014","categories":["other"],"row_index":224,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gates Self-closing PN-EN 16034:2014","search_zh":"大门 自闭合 PN-EN 16034:2014","test_object_zh":"大门","methodology_zh":"自闭合"},{"_id":"6a5a55f19af9f73f38250ff5","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Bramy","test_object_en":"Gates","methodology":"Trwałość samoczynnego zamykania","methodology_en":"Durability of self-closing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość samoczynnego zamykania","reference":"PN-EN 16034:2014","norm_bases":["PN-EN 16034:2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bramy Trwałość samoczynnego zamykania PN-EN 16034:2014 Bramy Trwalosc samoczynnego zamykania PN-EN 16034:2014","categories":["other"],"row_index":225,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gates Durability of self-closing PN-EN 16034:2014","search_zh":"大门 自闭合耐久性 PN-EN 16034:2014","test_object_zh":"大门","methodology_zh":"自闭合耐久性"},{"_id":"6a5a55f19af9f73f38250ff6","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Bramy","test_object_en":"Gates","methodology":"Bezpieczeństwo użytkowania bram z napędem: - Zagrożenie zgnieceniem, ścinaniem i wciągnięciem; - Siły otwierające i zamykające; - Wykrywanie obecności; - Zagrożenie zgnieceniem i ścinaniem spowodowane możliwością przemieszczenia się człowieka wraz z bramą; - Zagrożenie uderzeniem; - Obsługa ręczna; - Sprawdzenie bezpieczeństwa wynikającego z innych zagrożeń +","methodology_en":"Safety in use of power operated doors: - Risk of crushing, shearing and drawing-in; - Opening and closing forces; - Presence detection; - Risk of crushing and shearing caused by the possibility of a person being moved together with the door; - Risk of impact; - Manual operation; - Verification of safety with respect to other hazards +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Bezpieczeństwo użytkowania bram z napędem: - Zagrożenie zgnieceniem, ścinaniem i wciągnięciem; - Siły otwierające i zamykające; - Wykrywanie obecności; - Zagrożenie zgnieceniem i ścinaniem spowodowane możliwością przemieszczenia się człowieka wraz z bramą; - Zagrożenie uderzeniem; - Obsługa ręczna; - Sprawdzenie bezpieczeństwa wynikającego z innych zagrożeń +","reference":"PN-EN 12453:2017","norm_bases":["PN-EN 12453:2017"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bramy Bezpieczeństwo użytkowania bram z napędem: - Zagrożenie zgnieceniem, ścinaniem i wciągnięciem; - Siły otwierające i zamykające; - Wykrywanie obecności; - Zagrożenie zgnieceniem i ścinaniem spowodowane możliwością przemieszczenia się człowieka wraz z bramą; - Zagrożenie uderzeniem; - Obsługa ręczna; - Sprawdzenie bezpieczeństwa wynikającego z innych zagrożeń + PN-EN 12453:2017 Bramy Bezpieczenstwo uzytkowania bram z napedem: - Zagrozenie zgnieceniem, scinaniem i wciagnieciem; - Sily otwierajace i zamykajace; - Wykrywanie obecnosci; - Zagrozenie zgnieceniem i scinaniem spowodowane mozliwoscia przemieszczenia sie czlowieka wraz z brama; - Zagrozenie uderzeniem; - Obsluga reczna; - Sprawdzenie bezpieczenstwa wynikajacego z innych zagrozen + PN-EN 12453:2017","categories":["other"],"row_index":226,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gates Safety in use of power operated doors: - Risk of crushing, shearing and drawing-in; - Opening and closing forces; - Presence detection; - Risk of crushing and shearing caused by the possibility of a person being moved together with the door; - Risk of impact; - Manual operation; - Verification of safety with respect to other hazards + PN-EN 12453:2017","search_zh":"大门 PN-EN 12453:2017","test_object_zh":"大门"},{"_id":"6a5a55f19af9f73f38250ff7","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Bramy","test_object_en":"Gates","methodology":"Aspekty mechaniczne: - Projekt i konstrukcja; - Ochrona przed niezamierzonym lub niekontrolowanym ruchem; - Siły do obsługi ręcznej; - Urządzenia do obsługi ręcznej – sprawdzenie/kontrola umiejscowienia i bezpieczeństwa konstrukcji uchwytów pod kątem zagrożenia zgnieceniem, pochwyceniem lub przecięciem ręki; - Ochrona palców; - Weryfikacja specjalnych wymagań dotyczących elementów stosowanych w systemach zawieszenia i równoważenia; - Drzwi przejściowe - sprawdzenie/ kontrole wzrokowe bezpiecznego położenia, zabezpieczenia przed mimowolnym ruchem oraz wymagań dotyczących progów; - Znaki i/lub urządzenia ostrzegawcze – sprawdzenie i kontrola wzrokowa możliwości rozpoznania miejsc niebezpiecznych i zagrożeń za pomocą znaków/ urządzeń ostrzegawczych +","methodology_en":"Mechanical aspects: - Design and construction; - Protection against unintended or uncontrolled movement; - Manual operating forces; - Manual operating devices – checking/inspection of the location and safe design of handles with regard to the risk of crushing, trapping or cutting of the hand; - Finger protection; - Verification of special requirements for components used in suspension and counterbalancing systems; - Pass doors - checking/ visual inspection of the safe position, protection against unintended movement and requirements for thresholds; - Warning signs and/or devices – checking and visual inspection of the possibility of identifying dangerous places and hazards by means of warning signs/ devices +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Aspekty mechaniczne: - Projekt i konstrukcja; - Ochrona przed niezamierzonym lub niekontrolowanym ruchem; - Siły do obsługi ręcznej; - Urządzenia do obsługi ręcznej – sprawdzenie/kontrola umiejscowienia i bezpieczeństwa konstrukcji uchwytów pod kątem zagrożenia zgnieceniem, pochwyceniem lub przecięciem ręki; - Ochrona palców; - Weryfikacja specjalnych wymagań dotyczących elementów stosowanych w systemach zawieszenia i równoważenia; - Drzwi przejściowe - sprawdzenie/ kontrole wzrokowe bezpiecznego położenia, zabezpieczenia przed mimowolnym ruchem oraz wymagań dotyczących progów; - Znaki i/lub urządzenia ostrzegawcze – sprawdzenie i kontrola wzrokowa możliwości rozpoznania miejsc niebezpiecznych i zagrożeń za pomocą znaków/ urządzeń ostrzegawczych +","reference":"PN-EN 12604:2017","norm_bases":["PN-EN 12604:2017"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bramy Aspekty mechaniczne: - Projekt i konstrukcja; - Ochrona przed niezamierzonym lub niekontrolowanym ruchem; - Siły do obsługi ręcznej; - Urządzenia do obsługi ręcznej – sprawdzenie/kontrola umiejscowienia i bezpieczeństwa konstrukcji uchwytów pod kątem zagrożenia zgnieceniem, pochwyceniem lub przecięciem ręki; - Ochrona palców; - Weryfikacja specjalnych wymagań dotyczących elementów stosowanych w systemach zawieszenia i równoważenia; - Drzwi przejściowe - sprawdzenie/ kontrole wzrokowe bezpiecznego położenia, zabezpieczenia przed mimowolnym ruchem oraz wymagań dotyczących progów; - Znaki i/lub urządzenia ostrzegawcze – sprawdzenie i kontrola wzrokowa możliwości rozpoznania miejsc niebezpiecznych i zagrożeń za pomocą znaków/ urządzeń ostrzegawczych + PN-EN 12604:2017 Bramy Aspekty mechaniczne: - Projekt i konstrukcja; - Ochrona przed niezamierzonym lub niekontrolowanym ruchem; - Sily do obslugi recznej; - Urzadzenia do obslugi recznej – sprawdzenie/kontrola umiejscowienia i bezpieczenstwa konstrukcji uchwytow pod katem zagrozenia zgnieceniem, pochwyceniem lub przecieciem reki; - Ochrona palcow; - Weryfikacja specjalnych wymagan dotyczacych elementow stosowanych w systemach zawieszenia i rownowazenia; - Drzwi przejsciowe - sprawdzenie/ kontrole wzrokowe bezpiecznego polozenia, zabezpieczenia przed mimowolnym ruchem oraz wymagan dotyczacych progow; - Znaki i/lub urzadzenia ostrzegawcze – sprawdzenie i kontrola wzrokowa mozliwosci rozpoznania miejsc niebezpiecznych i zagrozen za pomoca znakow/ urzadzen ostrzegawczych + PN-EN 12604:2017","categories":["other"],"row_index":227,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gates Mechanical aspects: - Design and construction; - Protection against unintended or uncontrolled movement; - Manual operating forces; - Manual operating devices – checking/inspection of the location and safe design of handles with regard to the risk of crushing, trapping or cutting of the hand; - Finger protection; - Verification of special requirements for components used in suspension and counterbalancing systems; - Pass doors - checking/ visual inspection of the safe position, protection against unintended movement and requirements for thresholds; - Warning signs and/or devices – checking and visual inspection of the possibility of identifying dangerous places and hazards by means of warning signs/ devices + PN-EN 12604:2017","search_zh":"大门 PN-EN 12604:2017","test_object_zh":"大门"},{"_id":"6a5a55f19af9f73f38250ff8","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi z napędem, napędy do drzwi","test_object_en":"Powered doors, door operators","methodology":"Trwałość w ekstremalnych temperaturach: - od -30 °C do + 5 °C - od +40 °C do +80 °C","methodology_en":"Durability at extreme temperatures: - from -30 °C to + 5 °C - from +40 °C to +80 °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość w ekstremalnych temperaturach: - od -30 °C do + 5 °C - od +40 °C do +80 °C","reference":"PN-EN 16005:2013","norm_bases":["PN-EN 16005:2013"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi z napędem, napędy do drzwi Trwałość w ekstremalnych temperaturach: - od -30 °C do + 5 °C - od +40 °C do +80 °C PN-EN 16005:2013 Drzwi z napedem, napedy do drzwi Trwalosc w ekstremalnych temperaturach: - od -30 °C do + 5 °C - od +40 °C do +80 °C PN-EN 16005:2013","categories":["other"],"row_index":228,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Powered doors, door operators Durability at extreme temperatures: - from -30 °C to + 5 °C - from +40 °C to +80 °C PN-EN 16005:2013"},{"_id":"6a5a55f19af9f73f38250ff9","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Odporność na włamanie - wytrzymałość statyczna","methodology_en":"Burglary resistance - static strength","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na włamanie - wytrzymałość statyczna","reference":"PN-90/B-92270 pkt. 3.3.3 do 3.3.11 oraz 3.4 i 3.5","norm_bases":["PN-90/B-92270 pkt. 3.3.3 do 3.3.11 oraz 3.4 i 3.5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Odporność na włamanie - wytrzymałość statyczna PN-90/B-92270 pkt. 3.3.3 do 3.3.11 oraz 3.4 i 3.5 Drzwi, zespoly drzwiowe, skrzydla, oscieznice w tym m.in.: - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - uruchamiane recznie i z napedami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Odpornosc na wlamanie - wytrzymalosc statyczna PN-90/B-92270 pkt. 3.3.3 do 3.3.11 oraz 3.4 i 3.5","categories":["other"],"row_index":229,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes Burglary resistance - static strength PN-90/B-92270 pkt. 3.3.3 do 3.3.11 oraz 3.4 i 3.5","search_zh":"门、门组件、门扇、门框，其中包括：－ 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道 PN-90/B-92270 pkt. 3.3.3 do 3.3.11 oraz 3.4 i 3.5","test_object_zh":"门、门组件、门扇、门框，其中包括：－ 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道"},{"_id":"6a5a55f19af9f73f38250ffa","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Samoczynne zamykanie","methodology_en":"Self-closing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Samoczynne zamykanie","reference":"PN-EN 16034:2014","norm_bases":["PN-EN 16034:2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Samoczynne zamykanie PN-EN 16034:2014 Drzwi, zespoly drzwiowe, skrzydla, oscieznice w tym m.in.: - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - uruchamiane recznie i z napedami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Samoczynne zamykanie PN-EN 16034:2014","categories":["other"],"row_index":230,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes Self-closing PN-EN 16034:2014","search_zh":"门、门组件、门扇、门框，其中包括：－ 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道 自闭合 PN-EN 16034:2014","test_object_zh":"门、门组件、门扇、门框，其中包括：－ 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道","methodology_zh":"自闭合"},{"_id":"6a5a55f19af9f73f38250ffb","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Trwałość samoczynnego zamykania","methodology_en":"Durability of self-closing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość samoczynnego zamykania","reference":"PN-EN 16034:2014","norm_bases":["PN-EN 16034:2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Trwałość samoczynnego zamykania PN-EN 16034:2014 Drzwi, zespoly drzwiowe, skrzydla, oscieznice w tym m.in.: - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - uruchamiane recznie i z napedami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Trwalosc samoczynnego zamykania PN-EN 16034:2014","categories":["other"],"row_index":231,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes Durability of self-closing PN-EN 16034:2014","methodology_zh":"自闭合耐久性","search_zh":"门、门组件、门扇、门框，其中包括：－ 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道 自闭合耐久性 PN-EN 16034:2014","test_object_zh":"门、门组件、门扇、门框，其中包括：－ 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道"},{"_id":"6a5a55f19af9f73f38250ffc","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Przepuszczalność powietrza przy określonej różnicy ciśnień","methodology_en":"Air permeability at a specified pressure difference","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność powietrza przy określonej różnicy ciśnień","reference":"ASTM E283/E283M-19","norm_bases":["ASTM E283/E283M-19"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Przepuszczalność powietrza przy określonej różnicy ciśnień ASTM E283/E283M-19 Drzwi, zespoly drzwiowe, skrzydla, oscieznice w tym m.in.: - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - uruchamiane recznie i z napedami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Przepuszczalnosc powietrza przy okreslonej roznicy cisnien ASTM E283/E283M-19","categories":["other"],"row_index":232,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes Air permeability at a specified pressure difference ASTM E283/E283M-19","search_zh":"门、门组件、门扇、门框，其中包括：－ 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道 规定压差下的透气性 ASTM E283/E283M-19","test_object_zh":"门、门组件、门扇、门框，其中包括：－ 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道","methodology_zh":"规定压差下的透气性"},{"_id":"6a5a55f19af9f73f38250ffd","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Siła potrzebna do zaryglowania drzwi","methodology_en":"Force needed to bolt the door","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła potrzebna do zaryglowania drzwi","reference":"AAMA/WDMA/CSA 101/I.S.2/A440- 22","norm_bases":["AAMA/WDMA/CSA 101/I.S.2/A440- 22"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Siła potrzebna do zaryglowania drzwi AAMA/WDMA/CSA 101/I.S.2/A440- 22 Drzwi, zespoly drzwiowe, skrzydla, oscieznice w tym m.in.: - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - uruchamiane recznie i z napedami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Sila potrzebna do zaryglowania drzwi AAMA/WDMA/CSA 101/I.S.2/A440- 22","categories":["other"],"row_index":233,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes Force needed to bolt the door AAMA/WDMA/CSA 101/I.S.2/A440- 22","search_zh":"门、门组件、门扇、门框，其中包括：－ 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道 AAMA/WDMA/CSA 101/I.S.2/A440- 22","test_object_zh":"门、门组件、门扇、门框，其中包括：－ 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道"},{"_id":"6a5a55f19af9f73f38250ffe","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Siły operacyjne","methodology_en":"Operating forces","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siły operacyjne","reference":"AAMA/WDMA/CSA 101/I.S.2/A440- 22+ ASTM E2068-00(2022)","norm_bases":["AAMA/WDMA/CSA 101/I.S.2/A440- 22+ ASTM E2068-00(2022)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Siły operacyjne AAMA/WDMA/CSA 101/I.S.2/A440- 22+ ASTM E2068-00(2022) Drzwi, zespoly drzwiowe, skrzydla, oscieznice w tym m.in.: - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - uruchamiane recznie i z napedami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Sily operacyjne AAMA/WDMA/CSA 101/I.S.2/A440- 22+ ASTM E2068-00(2022)","categories":["other"],"row_index":234,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes Operating forces AAMA/WDMA/CSA 101/I.S.2/A440- 22+ ASTM E2068-00(2022)","methodology_zh":"操作力","search_zh":"门、门组件、门扇、门框，其中包括：－ 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道 操作力 AAMA/WDMA/CSA 101/I.S.2/A440- 22+ ASTM E2068-00(2022)","test_object_zh":"门、门组件、门扇、门框，其中包括：－ 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道"},{"_id":"6a5a55f19af9f73f38250fff","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Sztywność i wytrzymałość przy obciążeniu ciśnieniem statycznym","methodology_en":"Stiffness and strength under static pressure load","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sztywność i wytrzymałość przy obciążeniu ciśnieniem statycznym","reference":"ASTM E330/E330M-14(2021)","norm_bases":["ASTM E330/E330M-14(2021)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Sztywność i wytrzymałość przy obciążeniu ciśnieniem statycznym ASTM E330/E330M-14(2021) Drzwi, zespoly drzwiowe, skrzydla, oscieznice w tym m.in.: - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - uruchamiane recznie i z napedami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Sztywnosc i wytrzymalosc przy obciazeniu cisnieniem statycznym ASTM E330/E330M-14(2021)","categories":["other"],"row_index":235,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes Stiffness and strength under static pressure load ASTM E330/E330M-14(2021)","search_zh":"门、门组件、门扇、门框，其中包括：－ 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道 静压荷载下的刚度与强度 ASTM E330/E330M-14(2021)","test_object_zh":"门、门组件、门扇、门框，其中包括：－ 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道","methodology_zh":"静压荷载下的刚度与强度"},{"_id":"6a5a55f19af9f73f38251000","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Wodoszczelność przy cyklicznej statycznej różnicy ciśnień","methodology_en":"Watertightness under cyclic static pressure difference","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność przy cyklicznej statycznej różnicy ciśnień","reference":"ASTM E547-00(2016)","norm_bases":["ASTM E547-00(2016)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Wodoszczelność przy cyklicznej statycznej różnicy ciśnień ASTM E547-00(2016) Drzwi, zespoly drzwiowe, skrzydla, oscieznice w tym m.in.: - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - uruchamiane recznie i z napedami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Wodoszczelnosc przy cyklicznej statycznej roznicy cisnien ASTM E547-00(2016)","categories":["other"],"row_index":236,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes Watertightness under cyclic static pressure difference ASTM E547-00(2016)","search_zh":"门、门组件、门扇、门框，其中包括：－ 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道 循环静压差下的水密性 ASTM E547-00(2016)","test_object_zh":"门、门组件、门扇、门框，其中包括：－ 内门与外门 － 平开 － 推拉 － 折叠 － 弹簧 － 对折 － 旋转 － 手动与带驱动装置操作 － 带逃生推杆五金件 － 用于疏散通道","methodology_zh":"循环静压差下的水密性"},{"_id":"6a5a55f19af9f73f38251001","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy wykonane z metalu i tworzyw sztucznych","test_object_en":"Components made of metal and plastics","methodology":"Skręcanie Moment obrotowy Zakres: (0 - 350) Nm","methodology_en":"Torsion Torque Range: (0 - 350) Nm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skręcanie Moment obrotowy Zakres: (0 - 350) Nm","reference":"LOW-008/5/07-2014","norm_bases":["LOW-008/5/07-2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy wykonane z metalu i tworzyw sztucznych Skręcanie Moment obrotowy Zakres: (0 - 350) Nm LOW-008/5/07-2014 Elementy wykonane z metalu i tworzyw sztucznych Skrecanie Moment obrotowy Zakres: (0 - 350) Nm LOW-008/5/07-2014","categories":["materials"],"row_index":237,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Components made of metal and plastics Torsion Torque Range: (0 - 350) Nm LOW-008/5/07-2014","search_zh":"金属与塑料制构件 LOW-008/5/07-2014","test_object_zh":"金属与塑料制构件"},{"_id":"6a5a55f19af9f73f38251002","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy wykonane z metalu i tworzyw sztucznych","test_object_en":"Components made of metal and plastics","methodology":"Wytrzymałość na rozrywanie Zakres: (0 - 100) kN","methodology_en":"Tensile breaking strength Range: (0 - 100) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na rozrywanie Zakres: (0 - 100) kN","reference":"LOW-002/5/07-2014","norm_bases":["LOW-002/5/07-2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy wykonane z metalu i tworzyw sztucznych Wytrzymałość na rozrywanie Zakres: (0 - 100) kN LOW-002/5/07-2014 Elementy wykonane z metalu i tworzyw sztucznych Wytrzymalosc na rozrywanie Zakres: (0 - 100) kN LOW-002/5/07-2014","categories":["materials"],"row_index":238,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Components made of metal and plastics Tensile breaking strength Range: (0 - 100) kN LOW-002/5/07-2014","search_zh":"金属与塑料制构件 LOW-002/5/07-2014","test_object_zh":"金属与塑料制构件"},{"_id":"6a5a55f19af9f73f38251003","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy wykonane z metalu i tworzyw sztucznych","test_object_en":"Components made of metal and plastics","methodology":"Wytrzymałość na ściskanie Zakres: (0 - 100) kN","methodology_en":"Compressive strength Range: (0 - 100) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie Zakres: (0 - 100) kN","reference":"LOW-003/5/07-2014","norm_bases":["LOW-003/5/07-2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy wykonane z metalu i tworzyw sztucznych Wytrzymałość na ściskanie Zakres: (0 - 100) kN LOW-003/5/07-2014 Elementy wykonane z metalu i tworzyw sztucznych Wytrzymalosc na sciskanie Zakres: (0 - 100) kN LOW-003/5/07-2014","categories":["materials"],"row_index":239,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Components made of metal and plastics Compressive strength Range: (0 - 100) kN LOW-003/5/07-2014","search_zh":"金属与塑料制构件 LOW-003/5/07-2014","test_object_zh":"金属与塑料制构件"},{"_id":"6a5a55f19af9f73f38251004","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy wykonane z metalu i tworzyw sztucznych","test_object_en":"Components made of metal and plastics","methodology":"Wytrzymałość na zginanie Zakres: (0 - 100) kN","methodology_en":"Bending strength Range: (0 - 100) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na zginanie Zakres: (0 - 100) kN","reference":"LOW-004/5/07-2014","norm_bases":["LOW-004/5/07-2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy wykonane z metalu i tworzyw sztucznych Wytrzymałość na zginanie Zakres: (0 - 100) kN LOW-004/5/07-2014 Elementy wykonane z metalu i tworzyw sztucznych Wytrzymalosc na zginanie Zakres: (0 - 100) kN LOW-004/5/07-2014","categories":["materials"],"row_index":240,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Components made of metal and plastics Bending strength Range: (0 - 100) kN LOW-004/5/07-2014","search_zh":"金属与塑料制构件 LOW-004/5/07-2014","test_object_zh":"金属与塑料制构件"},{"_id":"6a5a55f19af9f73f38251005","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy szkieletowej konstrukcji metalowej","test_object_en":"Elements of metal skeleton structures","methodology":"Grubość powłoki","methodology_en":"Coating thickness","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Grubość powłoki","reference":"PN-EN ISO 2808:2008 pkt. 5.5.7 i 5.5.8","norm_bases":["PN-EN ISO 2808:2008 pkt. 5.5.7 i 5.5.8"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy szkieletowej konstrukcji metalowej Grubość powłoki PN-EN ISO 2808:2008 pkt. 5.5.7 i 5.5.8 Elementy szkieletowej konstrukcji metalowej Grubosc powloki PN-EN ISO 2808:2008 pkt. 5.5.7 i 5.5.8","categories":["materials"],"row_index":241,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Elements of metal skeleton structures Coating thickness PN-EN ISO 2808:2008 pkt. 5.5.7 i 5.5.8","methodology_zh":"涂层厚度","search_zh":"涂层厚度 PN-EN ISO 2808:2008 pkt. 5.5.7 i 5.5.8"},{"_id":"6a5a55f19af9f73f38251006","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy wyposażenia budownictwa","test_object_en":"Building equipment components","methodology":"Siła działania w zakresie (0 - 5000) N +","methodology_en":"Operating force in the range (0 - 5000) N +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła działania w zakresie (0 - 5000) N +","reference":"LOW-012/6/07-2014","norm_bases":["LOW-012/6/07-2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy wyposażenia budownictwa Siła działania w zakresie (0 - 5000) N + LOW-012/6/07-2014 Elementy wyposazenia budownictwa Sila dzialania w zakresie (0 - 5000) N + LOW-012/6/07-2014","categories":["other"],"row_index":242,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building equipment components Operating force in the range (0 - 5000) N + LOW-012/6/07-2014","search_zh":"建筑配套构件 LOW-012/6/07-2014","test_object_zh":"建筑配套构件"},{"_id":"6a5a55f19af9f73f38251007","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy wyposażenia budownictwa","test_object_en":"Building equipment components","methodology":"Działanie mechanizmów Moment obrotowy Zakres: (0 - 350) Nm","methodology_en":"Operation of mechanisms Torque Range: (0 - 350) Nm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Działanie mechanizmów Moment obrotowy Zakres: (0 - 350) Nm","reference":"LOW-008/5/07-2014","norm_bases":["LOW-008/5/07-2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy wyposażenia budownictwa Działanie mechanizmów Moment obrotowy Zakres: (0 - 350) Nm LOW-008/5/07-2014 Elementy wyposazenia budownictwa Dzialanie mechanizmow Moment obrotowy Zakres: (0 - 350) Nm LOW-008/5/07-2014","categories":["other"],"row_index":243,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building equipment components Operation of mechanisms Torque Range: (0 - 350) Nm LOW-008/5/07-2014","search_zh":"建筑配套构件 LOW-008/5/07-2014","test_object_zh":"建筑配套构件"},{"_id":"6a5a55f19af9f73f38251008","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy wyposażenia budownictwa","test_object_en":"Building equipment components","methodology":"Wymiary geometryczne liniowe i kątowe + Suwmiarki, Zakres: (0 - 400) mm Mikrometry, Zakres: (0 - 100) mm Przymiary sztywne, Zakres: (0 - 2000) mm Przymiary wstęgowe, Zakres: (0 - 8) m Kątomierz, Zakres: (0 - 360)°","methodology_en":"Linear and angular geometric dimensions + Calipers, Range: (0 - 400) mm Micrometers, Range: (0 - 100) mm Rigid rules, Range: (0 - 2000) mm Tape measures, Range: (0 - 8) m Protractor, Range: (0 - 360)°","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary geometryczne liniowe i kątowe + Suwmiarki, Zakres: (0 - 400) mm Mikrometry, Zakres: (0 - 100) mm Przymiary sztywne, Zakres: (0 - 2000) mm Przymiary wstęgowe, Zakres: (0 - 8) m Kątomierz, Zakres: (0 - 360)°","reference":"LOW-001/4/09-2007","norm_bases":["LOW-001/4/09-2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy wyposażenia budownictwa Wymiary geometryczne liniowe i kątowe + Suwmiarki, Zakres: (0 - 400) mm Mikrometry, Zakres: (0 - 100) mm Przymiary sztywne, Zakres: (0 - 2000) mm Przymiary wstęgowe, Zakres: (0 - 8) m Kątomierz, Zakres: (0 - 360)° LOW-001/4/09-2007 Elementy wyposazenia budownictwa Wymiary geometryczne liniowe i katowe + Suwmiarki, Zakres: (0 - 400) mm Mikrometry, Zakres: (0 - 100) mm Przymiary sztywne, Zakres: (0 - 2000) mm Przymiary wstegowe, Zakres: (0 - 8) m Katomierz, Zakres: (0 - 360)° LOW-001/4/09-2007","categories":["other"],"row_index":244,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building equipment components Linear and angular geometric dimensions + Calipers, Range: (0 - 400) mm Micrometers, Range: (0 - 100) mm Rigid rules, Range: (0 - 2000) mm Tape measures, Range: (0 - 8) m Protractor, Range: (0 - 360)° LOW-001/4/09-2007","search_zh":"建筑配套构件 LOW-001/4/09-2007","test_object_zh":"建筑配套构件"},{"_id":"6a5a55f19af9f73f38251009","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy wyposażenia budownictwa","test_object_en":"Building equipment components","methodology":"Trwałość mechanizmów obracających się w osi z jedno- lub dwukierunkowym ruchem wymuszonym","methodology_en":"Durability of mechanisms rotating about an axis with one- or two-directional forced movement","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość mechanizmów obracających się w osi z jedno- lub dwukierunkowym ruchem wymuszonym","reference":"LOW-007/4/09-2007","norm_bases":["LOW-007/4/09-2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy wyposażenia budownictwa Trwałość mechanizmów obracających się w osi z jedno- lub dwukierunkowym ruchem wymuszonym LOW-007/4/09-2007 Elementy wyposazenia budownictwa Trwalosc mechanizmow obracajacych sie w osi z jedno- lub dwukierunkowym ruchem wymuszonym LOW-007/4/09-2007","categories":["other"],"row_index":245,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building equipment components Durability of mechanisms rotating about an axis with one- or two-directional forced movement LOW-007/4/09-2007","search_zh":"建筑配套构件 LOW-007/4/09-2007","test_object_zh":"建筑配套构件"},{"_id":"6a5a55f19af9f73f3825100a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy wyposażenia budownictwa","test_object_en":"Building equipment components","methodology":"Trwałość mechanizmów z ruchem posuwisto-zwrotnym przy działaniu siłą prostopadłą lub równoległą do ruchu mechanizmu lub w osi przesuwu","methodology_en":"Durability of mechanisms with reciprocating movement under a force perpendicular or parallel to the movement of the mechanism or along the axis of travel","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość mechanizmów z ruchem posuwisto-zwrotnym przy działaniu siłą prostopadłą lub równoległą do ruchu mechanizmu lub w osi przesuwu","reference":"LOW-006/4/09-2007","norm_bases":["LOW-006/4/09-2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy wyposażenia budownictwa Trwałość mechanizmów z ruchem posuwisto-zwrotnym przy działaniu siłą prostopadłą lub równoległą do ruchu mechanizmu lub w osi przesuwu LOW-006/4/09-2007 Elementy wyposazenia budownictwa Trwalosc mechanizmow z ruchem posuwisto-zwrotnym przy dzialaniu sila prostopadla lub rownolegla do ruchu mechanizmu lub w osi przesuwu LOW-006/4/09-2007","categories":["other"],"row_index":246,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building equipment components Durability of mechanisms with reciprocating movement under a force perpendicular or parallel to the movement of the mechanism or along the axis of travel LOW-006/4/09-2007","search_zh":"建筑配套构件 LOW-006/4/09-2007","test_object_zh":"建筑配套构件"},{"_id":"6a5a55f19af9f73f3825100b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy wyposażenia budownictwa","test_object_en":"Building equipment components","methodology":"Trwałość mechanizmów ze zmianą ruchu obrotowego na posuwisto-zwrotny","methodology_en":"Durability of mechanisms converting rotary motion into reciprocating motion","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość mechanizmów ze zmianą ruchu obrotowego na posuwisto-zwrotny","reference":"LOW-005/4/09-2007","norm_bases":["LOW-005/4/09-2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy wyposażenia budownictwa Trwałość mechanizmów ze zmianą ruchu obrotowego na posuwisto-zwrotny LOW-005/4/09-2007 Elementy wyposazenia budownictwa Trwalosc mechanizmow ze zmiana ruchu obrotowego na posuwisto-zwrotny LOW-005/4/09-2007","categories":["other"],"row_index":247,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building equipment components Durability of mechanisms converting rotary motion into reciprocating motion LOW-005/4/09-2007","search_zh":"建筑配套构件 LOW-005/4/09-2007","test_object_zh":"建筑配套构件"},{"_id":"6a5a55f19af9f73f3825100c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy wyposażenia budownictwa","test_object_en":"Building equipment components","methodology":"Wytrzymałość na rozrywanie w zakresie: (0 - 100) kN","methodology_en":"Breaking strength in the range: (0 - 100) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na rozrywanie w zakresie: (0 - 100) kN","reference":"LOW-002/5/07-2014","norm_bases":["LOW-002/5/07-2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy wyposażenia budownictwa Wytrzymałość na rozrywanie w zakresie: (0 - 100) kN LOW-002/5/07-2014 Elementy wyposazenia budownictwa Wytrzymalosc na rozrywanie w zakresie: (0 - 100) kN LOW-002/5/07-2014","categories":["other"],"row_index":248,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building equipment components Breaking strength in the range: (0 - 100) kN LOW-002/5/07-2014","search_zh":"建筑配套构件 LOW-002/5/07-2014","test_object_zh":"建筑配套构件"},{"_id":"6a5a55f19af9f73f3825100d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy wyposażenia budownictwa","test_object_en":"Building equipment components","methodology":"Wytrzymałość na ściskanie w zakresie: (0 - 100) kN","methodology_en":"Compressive strength in the range: (0 - 100) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie w zakresie: (0 - 100) kN","reference":"LOW-003/5/07-2014","norm_bases":["LOW-003/5/07-2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy wyposażenia budownictwa Wytrzymałość na ściskanie w zakresie: (0 - 100) kN LOW-003/5/07-2014 Elementy wyposazenia budownictwa Wytrzymalosc na sciskanie w zakresie: (0 - 100) kN LOW-003/5/07-2014","categories":["other"],"row_index":249,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building equipment components Compressive strength in the range: (0 - 100) kN LOW-003/5/07-2014","search_zh":"建筑配套构件 LOW-003/5/07-2014","test_object_zh":"建筑配套构件"},{"_id":"6a5a55f19af9f73f3825100e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy wyposażenia budownictwa","test_object_en":"Building equipment components","methodology":"Wytrzymałość na zginanie w zakresie: (0 - 100) kN","methodology_en":"Flexural strength in the range: (0 - 100) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na zginanie w zakresie: (0 - 100) kN","reference":"LOW-004/5/07-2014","norm_bases":["LOW-004/5/07-2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy wyposażenia budownictwa Wytrzymałość na zginanie w zakresie: (0 - 100) kN LOW-004/5/07-2014 Elementy wyposazenia budownictwa Wytrzymalosc na zginanie w zakresie: (0 - 100) kN LOW-004/5/07-2014","categories":["other"],"row_index":250,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building equipment components Flexural strength in the range: (0 - 100) kN LOW-004/5/07-2014","search_zh":"建筑配套构件 LOW-004/5/07-2014","test_object_zh":"建筑配套构件"},{"_id":"6a5a55f19af9f73f3825100f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kłódki","test_object_en":"Padlocks","methodology":"Trwałość","methodology_en":"Durability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość","reference":"PN-EN 12320:2013-04","norm_bases":["PN-EN 12320:2013-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kłódki Trwałość PN-EN 12320:2013-04 Klodki Trwalosc PN-EN 12320:2013-04","categories":["other"],"row_index":251,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Padlocks Durability PN-EN 12320:2013-04","methodology_zh":"耐久性","search_zh":"耐久性 PN-EN 12320:2013-04"},{"_id":"6a5a55f19af9f73f38251010","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kłódki","test_object_en":"Padlocks","methodology":"Odporność na działania niekonwencjonalne","methodology_en":"Resistance to unconventional attacks","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działania niekonwencjonalne","reference":"LZE-015/5/12-2019","norm_bases":["LZE-015/5/12-2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kłódki Odporność na działania niekonwencjonalne LZE-015/5/12-2019 Klodki Odpornosc na dzialania niekonwencjonalne LZE-015/5/12-2019","categories":["other"],"row_index":252,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Padlocks Resistance to unconventional attacks LZE-015/5/12-2019","methodology_zh":"非常规攻击的耐受性","search_zh":"非常规攻击的耐受性 LZE-015/5/12-2019"},{"_id":"6a5a55f19af9f73f38251011","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kłódki mechatroniczne","test_object_en":"Mechatronic padlocks","methodology":"Wytrzymałość klucza","methodology_en":"Key strength","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość klucza","reference":"PN-EN 16864:2017-10","norm_bases":["PN-EN 16864:2017-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kłódki mechatroniczne Wytrzymałość klucza PN-EN 16864:2017-10 Klodki mechatroniczne Wytrzymalosc klucza PN-EN 16864:2017-10","categories":["other"],"row_index":253,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mechatronic padlocks Key strength PN-EN 16864:2017-10","search_zh":"机电挂锁 钥匙强度 PN-EN 16864:2017-10","test_object_zh":"机电挂锁","methodology_zh":"钥匙强度"},{"_id":"6a5a55f19af9f73f38251012","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kłódki mechatroniczne","test_object_en":"Mechatronic padlocks","methodology":"Moment operacyjny","methodology_en":"Operating moment","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moment operacyjny","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kłódki mechatroniczne Moment operacyjny Klodki mechatroniczne Moment operacyjny","categories":["other"],"row_index":254,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mechatronic padlocks Operating moment","search_zh":"机电挂锁","test_object_zh":"机电挂锁"},{"_id":"6a5a55f19af9f73f38251013","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kłódki mechatroniczne","test_object_en":"Mechatronic padlocks","methodology":"Stabilność klucza","methodology_en":"Stability of the key","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stabilność klucza","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kłódki mechatroniczne Stabilność klucza Klodki mechatroniczne Stabilnosc klucza","categories":["other"],"row_index":255,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mechatronic padlocks Stability of the key","search_zh":"机电挂锁","test_object_zh":"机电挂锁"},{"_id":"6a5a55f19af9f73f38251014","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kłódki mechatroniczne","test_object_en":"Mechatronic padlocks","methodology":"Zły kod elektroniczny","methodology_en":"Incorrect electronic code","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zły kod elektroniczny","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kłódki mechatroniczne Zły kod elektroniczny Klodki mechatroniczne Zly kod elektroniczny","categories":["electronics"],"row_index":256,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mechatronic padlocks Incorrect electronic code","search_zh":"机电挂锁","test_object_zh":"机电挂锁"},{"_id":"6a5a55f19af9f73f38251015","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kłódki mechatroniczne","test_object_en":"Mechatronic padlocks","methodology":"Trwałość","methodology_en":"Durability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kłódki mechatroniczne Trwałość Klodki mechatroniczne Trwalosc","categories":["other"],"row_index":257,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mechatronic padlocks Durability","methodology_zh":"耐久性","search_zh":"机电挂锁 耐久性","test_object_zh":"机电挂锁"},{"_id":"6a5a55f19af9f73f38251016","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kłódki mechatroniczne","test_object_en":"Mechatronic padlocks","methodology":"Odporność na korozję","methodology_en":"Corrosion resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na korozję","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kłódki mechatroniczne Odporność na korozję Klodki mechatroniczne Odpornosc na korozje","categories":["other"],"row_index":258,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mechatronic padlocks Corrosion resistance","methodology_zh":"耐腐蚀性","search_zh":"机电挂锁 耐腐蚀性","test_object_zh":"机电挂锁"},{"_id":"6a5a55f19af9f73f38251017","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kłódki mechatroniczne","test_object_en":"Mechatronic padlocks","methodology":"Odporność klucza na wodę","methodology_en":"Resistance of the key to water","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność klucza na wodę","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kłódki mechatroniczne Odporność klucza na wodę Klodki mechatroniczne Odpornosc klucza na wode","categories":["other"],"row_index":259,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mechatronic padlocks Resistance of the key to water","search_zh":"机电挂锁","test_object_zh":"机电挂锁"},{"_id":"6a5a55f19af9f73f38251018","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kłódki mechatroniczne","test_object_en":"Mechatronic padlocks","methodology":"Zabezpieczenie związane z kluczem","methodology_en":"Key-related protection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zabezpieczenie związane z kluczem","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kłódki mechatroniczne Zabezpieczenie związane z kluczem Klodki mechatroniczne Zabezpieczenie zwiazane z kluczem","categories":["other"],"row_index":260,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mechatronic padlocks Key-related protection","search_zh":"机电挂锁 与钥匙相关的防护","test_object_zh":"机电挂锁","methodology_zh":"与钥匙相关的防护"},{"_id":"6a5a55f19af9f73f38251019","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kłódki mechatroniczne","test_object_en":"Mechatronic padlocks","methodology":"Odporność na atak przecinakiem","methodology_en":"Resistance to chisel attack","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na atak przecinakiem","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kłódki mechatroniczne Odporność na atak przecinakiem Klodki mechatroniczne Odpornosc na atak przecinakiem","categories":["other"],"row_index":261,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mechatronic padlocks Resistance to chisel attack","search_zh":"机电挂锁 抗凿击性","test_object_zh":"机电挂锁","methodology_zh":"抗凿击性"},{"_id":"6a5a55f19af9f73f3825101a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kłódki mechatroniczne","test_object_en":"Mechatronic padlocks","methodology":"Odporność na atak przez ukręcenie","methodology_en":"Resistance to attack by twisting off","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na atak przez ukręcenie","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kłódki mechatroniczne Odporność na atak przez ukręcenie Klodki mechatroniczne Odpornosc na atak przez ukrecenie","categories":["other"],"row_index":262,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mechatronic padlocks Resistance to attack by twisting off","search_zh":"机电挂锁","test_object_zh":"机电挂锁"},{"_id":"6a5a55f19af9f73f3825101b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kłódki mechatroniczne","test_object_en":"Mechatronic padlocks","methodology":"Odporność na atak przez wyrywanie","methodology_en":"Resistance to attack by pulling out","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na atak przez wyrywanie","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kłódki mechatroniczne Odporność na atak przez wyrywanie Klodki mechatroniczne Odpornosc na atak przez wyrywanie","categories":["other"],"row_index":263,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mechatronic padlocks Resistance to attack by pulling out","search_zh":"机电挂锁","test_object_zh":"机电挂锁"},{"_id":"6a5a55f19af9f73f3825101c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kłódki mechatroniczne","test_object_en":"Mechatronic padlocks","methodology":"Odporność na atak przez uderzenia (ręczne)","methodology_en":"Resistance to attack by impact (manual)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na atak przez uderzenia (ręczne)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kłódki mechatroniczne Odporność na atak przez uderzenia (ręczne) Klodki mechatroniczne Odpornosc na atak przez uderzenia (reczne)","categories":["other"],"row_index":264,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mechatronic padlocks Resistance to attack by impact (manual)","search_zh":"机电挂锁","test_object_zh":"机电挂锁"},{"_id":"6a5a55f19af9f73f3825101d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kłódki mechatroniczne","test_object_en":"Mechatronic padlocks","methodology":"Odporność na atak przez wibrację","methodology_en":"Resistance to attack by vibration","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na atak przez wibrację","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kłódki mechatroniczne Odporność na atak przez wibrację Klodki mechatroniczne Odpornosc na atak przez wibracje","categories":["other"],"row_index":265,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mechatronic padlocks Resistance to attack by vibration","search_zh":"机电挂锁","test_object_zh":"机电挂锁"},{"_id":"6a5a55f19af9f73f3825101e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kłódki mechatroniczne","test_object_en":"Mechatronic padlocks","methodology":"Odporność na atak przez zwiększone napięcie","methodology_en":"Resistance to attack by increased voltage","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na atak przez zwiększone napięcie","reference":"PN-EN 16864:2017-10","norm_bases":["PN-EN 16864:2017-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kłódki mechatroniczne Odporność na atak przez zwiększone napięcie PN-EN 16864:2017-10 Klodki mechatroniczne Odpornosc na atak przez zwiekszone napiecie PN-EN 16864:2017-10","categories":["other"],"row_index":266,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mechatronic padlocks Resistance to attack by increased voltage PN-EN 16864:2017-10","search_zh":"机电挂锁 PN-EN 16864:2017-10","test_object_zh":"机电挂锁"},{"_id":"6a5a55f19af9f73f3825101f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kłódki mechatroniczne","test_object_en":"Mechatronic padlocks","methodology":"Odporność na atak polem magnetycznym","methodology_en":"Resistance to attack by magnetic field","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na atak polem magnetycznym","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kłódki mechatroniczne Odporność na atak polem magnetycznym Klodki mechatroniczne Odpornosc na atak polem magnetycznym","categories":["other"],"row_index":267,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mechatronic padlocks Resistance to attack by magnetic field","search_zh":"机电挂锁","test_object_zh":"机电挂锁"},{"_id":"6a5a55f19af9f73f38251020","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Napędy do bram i drzwi","test_object_en":"Drives for gates and doors","methodology":"Bezpieczeństwo użytkowania +","methodology_en":"Safety in use +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Bezpieczeństwo użytkowania +","reference":"PN-EN 12445:2002 pkt. 4.1","norm_bases":["PN-EN 12445:2002 pkt. 4.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Napędy do bram i drzwi Bezpieczeństwo użytkowania + PN-EN 12445:2002 pkt. 4.1 Napedy do bram i drzwi Bezpieczenstwo uzytkowania + PN-EN 12445:2002 pkt. 4.1","categories":["other"],"row_index":268,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Drives for gates and doors Safety in use + PN-EN 12445:2002 pkt. 4.1"},{"_id":"6a5a55f19af9f73f38251021","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Napędy do bram i drzwi","test_object_en":"Drives for gates and doors","methodology":"Funkcjonalność +","methodology_en":"Functionality +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Funkcjonalność +","reference":"PN-EN 12605:2002 pkt 5.1","norm_bases":["PN-EN 12605:2002 pkt 5.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Napędy do bram i drzwi Funkcjonalność + PN-EN 12605:2002 pkt 5.1 Napedy do bram i drzwi Funkcjonalnosc + PN-EN 12605:2002 pkt 5.1","categories":["other"],"row_index":269,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Drives for gates and doors Functionality + PN-EN 12605:2002 pkt 5.1","methodology_zh":"功能性 +","search_zh":"功能性 + PN-EN 12605:2002 pkt 5.1"},{"_id":"6a5a55f19af9f73f38251022","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Napędy do drzwi, bram i żaluzji","test_object_en":"Drives for doors, gates and shutters","methodology":"Siła działania + Zakres: (0 - 5000) N","methodology_en":"Operating force + Range: (0 - 5000) N","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła działania + Zakres: (0 - 5000) N","reference":"LOW-012/6/07-2014","norm_bases":["LOW-012/6/07-2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Napędy do drzwi, bram i żaluzji Siła działania + Zakres: (0 - 5000) N LOW-012/6/07-2014 Napedy do drzwi, bram i zaluzji Sila dzialania + Zakres: (0 - 5000) N LOW-012/6/07-2014","categories":["other"],"row_index":270,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Drives for doors, gates and shutters Operating force + Range: (0 - 5000) N LOW-012/6/07-2014"},{"_id":"6a5a55f19af9f73f38251023","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Napędy do drzwi, bram i żaluzji","test_object_en":"Drives for doors, gates and shutters","methodology":"Wytrzymałość na ściskanie","methodology_en":"Compressive strength","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie","reference":"LOW-003/5/07-2014","norm_bases":["LOW-003/5/07-2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Napędy do drzwi, bram i żaluzji Wytrzymałość na ściskanie LOW-003/5/07-2014 Napedy do drzwi, bram i zaluzji Wytrzymalosc na sciskanie LOW-003/5/07-2014","categories":["other"],"row_index":271,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Drives for doors, gates and shutters Compressive strength LOW-003/5/07-2014","methodology_zh":"抗压强度","search_zh":"抗压强度 LOW-003/5/07-2014"},{"_id":"6a5a55f19af9f73f38251024","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okucia budowlane i ich elementy","test_object_en":"Building hardware and its components","methodology":"Działanie mechanizmów obciążonych siłą, siła działania siłomierze (0 - 5000) N","methodology_en":"Operation of force-loaded mechanisms, actuating force dynamometers (0 - 5000) N","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Działanie mechanizmów obciążonych siłą, siła działania siłomierze (0 - 5000) N","reference":"LOW-012/6/07-2014","norm_bases":["LOW-012/6/07-2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okucia budowlane i ich elementy Działanie mechanizmów obciążonych siłą, siła działania siłomierze (0 - 5000) N LOW-012/6/07-2014 Okucia budowlane i ich elementy Dzialanie mechanizmow obciazonych sila, sila dzialania silomierze (0 - 5000) N LOW-012/6/07-2014","categories":["construction"],"row_index":272,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building hardware and its components Operation of force-loaded mechanisms, actuating force dynamometers (0 - 5000) N LOW-012/6/07-2014","search_zh":"建筑五金件及其构件 LOW-012/6/07-2014","test_object_zh":"建筑五金件及其构件"},{"_id":"6a5a55f19af9f73f38251025","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okucia budowlane i ich elementy","test_object_en":"Building hardware and its components","methodology":"Działanie mechanizmów Moment obrotowy w zakresie: (0-350) Nm","methodology_en":"Operation of mechanisms Torque in the range: (0-350) Nm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Działanie mechanizmów Moment obrotowy w zakresie: (0-350) Nm","reference":"LOW-008/5/07-2014","norm_bases":["LOW-008/5/07-2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okucia budowlane i ich elementy Działanie mechanizmów Moment obrotowy w zakresie: (0-350) Nm LOW-008/5/07-2014 Okucia budowlane i ich elementy Dzialanie mechanizmow Moment obrotowy w zakresie: (0-350) Nm LOW-008/5/07-2014","categories":["construction"],"row_index":273,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building hardware and its components Operation of mechanisms Torque in the range: (0-350) Nm LOW-008/5/07-2014","search_zh":"建筑五金件及其构件 LOW-008/5/07-2014","test_object_zh":"建筑五金件及其构件"},{"_id":"6a5a55f19af9f73f38251026","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okucia budowlane i ich elementy","test_object_en":"Building hardware and its components","methodology":"Wymiary geometryczne liniowe i kątowe + Suwmiarki, Zakres: (0 - 400) mm Mikrometry, Zakres: (0 - 100) mm Przymiary sztywne, Zakres: (0 - 2000) mm Przymiary wstęgowe, Zakres: (0 - 8) m Kątomierz, Zakres: (0 - 360)°","methodology_en":"Linear and angular geometric dimensions + Calipers, Range: (0 - 400) mm Micrometers, Range: (0 - 100) mm Rigid rules, Range: (0 - 2000) mm Tape measures, Range: (0 - 8) m Protractor, Range: (0 - 360)°","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary geometryczne liniowe i kątowe + Suwmiarki, Zakres: (0 - 400) mm Mikrometry, Zakres: (0 - 100) mm Przymiary sztywne, Zakres: (0 - 2000) mm Przymiary wstęgowe, Zakres: (0 - 8) m Kątomierz, Zakres: (0 - 360)°","reference":"LOW-001/4/09-2007","norm_bases":["LOW-001/4/09-2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okucia budowlane i ich elementy Wymiary geometryczne liniowe i kątowe + Suwmiarki, Zakres: (0 - 400) mm Mikrometry, Zakres: (0 - 100) mm Przymiary sztywne, Zakres: (0 - 2000) mm Przymiary wstęgowe, Zakres: (0 - 8) m Kątomierz, Zakres: (0 - 360)° LOW-001/4/09-2007 Okucia budowlane i ich elementy Wymiary geometryczne liniowe i katowe + Suwmiarki, Zakres: (0 - 400) mm Mikrometry, Zakres: (0 - 100) mm Przymiary sztywne, Zakres: (0 - 2000) mm Przymiary wstegowe, Zakres: (0 - 8) m Katomierz, Zakres: (0 - 360)° LOW-001/4/09-2007","categories":["construction"],"row_index":274,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building hardware and its components Linear and angular geometric dimensions + Calipers, Range: (0 - 400) mm Micrometers, Range: (0 - 100) mm Rigid rules, Range: (0 - 2000) mm Tape measures, Range: (0 - 8) m Protractor, Range: (0 - 360)° LOW-001/4/09-2007","search_zh":"建筑五金件及其构件 LOW-001/4/09-2007","test_object_zh":"建筑五金件及其构件"},{"_id":"6a5a55f19af9f73f38251027","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okucia budowlane i ich elementy","test_object_en":"Building hardware and its components","methodology":"Trwałość mechanizmów obracających się w osi z jedno- lub dwukierunkowym ruchem wymuszonym","methodology_en":"Durability of mechanisms rotating about an axis with one- or two-directional forced movement","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość mechanizmów obracających się w osi z jedno- lub dwukierunkowym ruchem wymuszonym","reference":"LOW-007/4/09-2007","norm_bases":["LOW-007/4/09-2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okucia budowlane i ich elementy Trwałość mechanizmów obracających się w osi z jedno- lub dwukierunkowym ruchem wymuszonym LOW-007/4/09-2007 Okucia budowlane i ich elementy Trwalosc mechanizmow obracajacych sie w osi z jedno- lub dwukierunkowym ruchem wymuszonym LOW-007/4/09-2007","categories":["construction"],"row_index":275,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building hardware and its components Durability of mechanisms rotating about an axis with one- or two-directional forced movement LOW-007/4/09-2007","search_zh":"建筑五金件及其构件 LOW-007/4/09-2007","test_object_zh":"建筑五金件及其构件"},{"_id":"6a5a55f19af9f73f38251028","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okucia budowlane i ich elementy","test_object_en":"Building hardware and its components","methodology":"Trwałość mechanizmów z ruchem posuwisto-zwrotnym przy działaniu siłą prostopadłą lub równoległą do ruchu mechanizmu lub w osi przesuwu","methodology_en":"Durability of mechanisms with reciprocating movement under a force perpendicular or parallel to the movement of the mechanism or along the axis of travel","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość mechanizmów z ruchem posuwisto-zwrotnym przy działaniu siłą prostopadłą lub równoległą do ruchu mechanizmu lub w osi przesuwu","reference":"LOW-006/4/09-2007","norm_bases":["LOW-006/4/09-2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okucia budowlane i ich elementy Trwałość mechanizmów z ruchem posuwisto-zwrotnym przy działaniu siłą prostopadłą lub równoległą do ruchu mechanizmu lub w osi przesuwu LOW-006/4/09-2007 Okucia budowlane i ich elementy Trwalosc mechanizmow z ruchem posuwisto-zwrotnym przy dzialaniu sila prostopadla lub rownolegla do ruchu mechanizmu lub w osi przesuwu LOW-006/4/09-2007","categories":["construction"],"row_index":276,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building hardware and its components Durability of mechanisms with reciprocating movement under a force perpendicular or parallel to the movement of the mechanism or along the axis of travel LOW-006/4/09-2007","search_zh":"建筑五金件及其构件 LOW-006/4/09-2007","test_object_zh":"建筑五金件及其构件"},{"_id":"6a5a55f19af9f73f38251029","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okucia budowlane i ich elementy","test_object_en":"Building hardware and its components","methodology":"Trwałość mechanizmów ze zmianą ruchu obrotowego na posuwisto- zwrotny","methodology_en":"Durability of mechanisms converting rotary motion into reciprocating motion","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość mechanizmów ze zmianą ruchu obrotowego na posuwisto- zwrotny","reference":"LOW-005/4/09-2007","norm_bases":["LOW-005/4/09-2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okucia budowlane i ich elementy Trwałość mechanizmów ze zmianą ruchu obrotowego na posuwisto- zwrotny LOW-005/4/09-2007 Okucia budowlane i ich elementy Trwalosc mechanizmow ze zmiana ruchu obrotowego na posuwisto- zwrotny LOW-005/4/09-2007","categories":["construction"],"row_index":277,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building hardware and its components Durability of mechanisms converting rotary motion into reciprocating motion LOW-005/4/09-2007","search_zh":"建筑五金件及其构件 LOW-005/4/09-2007","test_object_zh":"建筑五金件及其构件"},{"_id":"6a5a55f19af9f73f3825102a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okucia budowlane i ich elementy","test_object_en":"Building hardware and its components","methodology":"Wytrzymałość na rozrywanie Zakres: (0 - 100) kN","methodology_en":"Tensile breaking strength Range: (0 - 100) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na rozrywanie Zakres: (0 - 100) kN","reference":"LOW-002/5/07-2014","norm_bases":["LOW-002/5/07-2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okucia budowlane i ich elementy Wytrzymałość na rozrywanie Zakres: (0 - 100) kN LOW-002/5/07-2014 Okucia budowlane i ich elementy Wytrzymalosc na rozrywanie Zakres: (0 - 100) kN LOW-002/5/07-2014","categories":["construction"],"row_index":278,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building hardware and its components Tensile breaking strength Range: (0 - 100) kN LOW-002/5/07-2014","search_zh":"建筑五金件及其构件 LOW-002/5/07-2014","test_object_zh":"建筑五金件及其构件"},{"_id":"6a5a55f19af9f73f3825102b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okucia budowlane i ich elementy","test_object_en":"Building hardware and its components","methodology":"Wytrzymałość na ściskanie Zakres: (0 - 100) kN","methodology_en":"Compressive strength Range: (0 - 100) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie Zakres: (0 - 100) kN","reference":"LOW-003/5/07-2014","norm_bases":["LOW-003/5/07-2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okucia budowlane i ich elementy Wytrzymałość na ściskanie Zakres: (0 - 100) kN LOW-003/5/07-2014 Okucia budowlane i ich elementy Wytrzymalosc na sciskanie Zakres: (0 - 100) kN LOW-003/5/07-2014","categories":["construction"],"row_index":279,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building hardware and its components Compressive strength Range: (0 - 100) kN LOW-003/5/07-2014","search_zh":"建筑五金件及其构件 LOW-003/5/07-2014","test_object_zh":"建筑五金件及其构件"},{"_id":"6a5a55f19af9f73f3825102c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okucia budowlane i ich elementy","test_object_en":"Building hardware and its components","methodology":"Wytrzymałość na zginanie Zakres: (0 - 100) kN","methodology_en":"Bending strength Range: (0 - 100) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na zginanie Zakres: (0 - 100) kN","reference":"LOW-004/5/07-2014","norm_bases":["LOW-004/5/07-2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okucia budowlane i ich elementy Wytrzymałość na zginanie Zakres: (0 - 100) kN LOW-004/5/07-2014 Okucia budowlane i ich elementy Wytrzymalosc na zginanie Zakres: (0 - 100) kN LOW-004/5/07-2014","categories":["construction"],"row_index":280,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building hardware and its components Bending strength Range: (0 - 100) kN LOW-004/5/07-2014","search_zh":"建筑五金件及其构件 LOW-004/5/07-2014","test_object_zh":"建筑五金件及其构件"},{"_id":"6a5a55f19af9f73f3825102d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okucia uchylno-rozwierane, okucia rozwierano-uchylne, okucia uchylne, okucia rozwierane","test_object_en":"Tilt-and-turn fittings, turn-and-tilt fittings, tilt fittings, turn fittings","methodology":"Wytrzymałość okucia na obciążenia dynamiczne przy uderzeniu o przeszkodę","methodology_en":"Strength of the hardware under dynamic loads on impact against an obstacle","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość okucia na obciążenia dynamiczne przy uderzeniu o przeszkodę","reference":"PN-EN 13126-8:2007 pkt 7.3.6","norm_bases":["PN-EN 13126-8:2007 pkt 7.3.6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okucia uchylno-rozwierane, okucia rozwierano-uchylne, okucia uchylne, okucia rozwierane Wytrzymałość okucia na obciążenia dynamiczne przy uderzeniu o przeszkodę PN-EN 13126-8:2007 pkt 7.3.6 Okucia uchylno-rozwierane, okucia rozwierano-uchylne, okucia uchylne, okucia rozwierane Wytrzymalosc okucia na obciazenia dynamiczne przy uderzeniu o przeszkode PN-EN 13126-8:2007 pkt 7.3.6","categories":["other"],"row_index":281,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Tilt-and-turn fittings, turn-and-tilt fittings, tilt fittings, turn fittings Strength of the hardware under dynamic loads on impact against an obstacle PN-EN 13126-8:2007 pkt 7.3.6"},{"_id":"6a5a55f19af9f73f3825102e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okucia uchylno-rozwierane, okucia rozwierano-uchylne, okucia uchylne, okucia rozwierane","test_object_en":"Tilt-and-turn fittings, turn-and-tilt fittings, tilt fittings, turn fittings","methodology":"Wytrzymałość","methodology_en":"Strength","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość","reference":"PN-EN 13126-8:2007 pkt 7.3.5","norm_bases":["PN-EN 13126-8:2007 pkt 7.3.5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okucia uchylno-rozwierane, okucia rozwierano-uchylne, okucia uchylne, okucia rozwierane Wytrzymałość PN-EN 13126-8:2007 pkt 7.3.5 Okucia uchylno-rozwierane, okucia rozwierano-uchylne, okucia uchylne, okucia rozwierane Wytrzymalosc PN-EN 13126-8:2007 pkt 7.3.5","categories":["other"],"row_index":282,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Tilt-and-turn fittings, turn-and-tilt fittings, tilt fittings, turn fittings Strength PN-EN 13126-8:2007 pkt 7.3.5","methodology_zh":"强度","search_zh":"强度 PN-EN 13126-8:2007 pkt 7.3.5"},{"_id":"6a5a55f19af9f73f3825102f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Tworzywa sztuczne","test_object_en":"Plastics","methodology":"Moduł sprężystości przy rozciąganiu typ 2 i 5","methodology_en":"Modulus of elasticity in tension type 2 and 5","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moduł sprężystości przy rozciąganiu typ 2 i 5","reference":"PN-EN ISO 527-3:1998","norm_bases":["PN-EN ISO 527-3:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tworzywa sztuczne Moduł sprężystości przy rozciąganiu typ 2 i 5 PN-EN ISO 527-3:1998 Tworzywa sztuczne Modul sprezystosci przy rozciaganiu typ 2 i 5 PN-EN ISO 527-3:1998","categories":["materials"],"row_index":283,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastics Modulus of elasticity in tension type 2 and 5 PN-EN ISO 527-3:1998","search_zh":"塑料 PN-EN ISO 527-3:1998","test_object_zh":"塑料"},{"_id":"6a5a55f19af9f73f38251030","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Tworzywa sztuczne","test_object_en":"Plastics","methodology":"Twardość metodą Shore'a","methodology_en":"Hardness by the Shore method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Twardość metodą Shore'a","reference":"LOW-T01/3/09-2007","norm_bases":["LOW-T01/3/09-2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tworzywa sztuczne Twardość metodą Shore'a LOW-T01/3/09-2007 Tworzywa sztuczne Twardosc metoda Shore'a LOW-T01/3/09-2007","categories":["materials"],"row_index":284,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastics Hardness by the Shore method LOW-T01/3/09-2007","search_zh":"塑料 LOW-T01/3/09-2007","test_object_zh":"塑料"},{"_id":"6a5a55f19af9f73f38251031","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wkładki bębenkowe","test_object_en":"Cylinder locks","methodology":"Odporność na działania niekonwencjonalne","methodology_en":"Resistance to unconventional attacks","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działania niekonwencjonalne","reference":"LZE-015/5/12-2019","norm_bases":["LZE-015/5/12-2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkładki bębenkowe Odporność na działania niekonwencjonalne LZE-015/5/12-2019 Wkladki bebenkowe Odpornosc na dzialania niekonwencjonalne LZE-015/5/12-2019","categories":["other"],"row_index":285,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Cylinder locks Resistance to unconventional attacks LZE-015/5/12-2019","search_zh":"圆柱锁芯 非常规攻击的耐受性 LZE-015/5/12-2019","test_object_zh":"圆柱锁芯","methodology_zh":"非常规攻击的耐受性"},{"_id":"6a5a55f19af9f73f38251032","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wkładki bębenkowe","test_object_en":"Cylinder locks","methodology":"Odporność na działania niekonwencjonalne","methodology_en":"Resistance to unconventional attacks","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działania niekonwencjonalne","reference":"PN-91/B-94461/02","norm_bases":["PN-91/B-94461/02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkładki bębenkowe Odporność na działania niekonwencjonalne PN-91/B-94461/02 Wkladki bebenkowe Odpornosc na dzialania niekonwencjonalne PN-91/B-94461/02","categories":["other"],"row_index":286,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Cylinder locks Resistance to unconventional attacks PN-91/B-94461/02","search_zh":"圆柱锁芯 非常规攻击的耐受性 PN-91/B-94461/02","test_object_zh":"圆柱锁芯","methodology_zh":"非常规攻击的耐受性"},{"_id":"6a5a55f19af9f73f38251033","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamki i zaczepy","test_object_en":"Locks and strikes","methodology":"Wytrzymałość","methodology_en":"Strength","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość","reference":"PN-91/B-94408 pkt. 6 PN-91/B-94400 pkt. 5.4 i 5.5","norm_bases":["PN-91/B-94408 pkt. 6 PN-91/B-94400 pkt. 5.4 i 5.5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamki i zaczepy Wytrzymałość PN-91/B-94408 pkt. 6 PN-91/B-94400 pkt. 5.4 i 5.5 Zamki i zaczepy Wytrzymalosc PN-91/B-94408 pkt. 6 PN-91/B-94400 pkt. 5.4 i 5.5","categories":["other"],"row_index":287,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Locks and strikes Strength PN-91/B-94408 pkt. 6 PN-91/B-94400 pkt. 5.4 i 5.5","search_zh":"锁具与锁扣板 强度 PN-91/B-94408 pkt. 6 PN-91/B-94400 pkt. 5.4 i 5.5","test_object_zh":"锁具与锁扣板","methodology_zh":"强度"},{"_id":"6a5a55f19af9f73f38251034","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamki i zaczepy","test_object_en":"Locks and strikes","methodology":"Zabezpieczenie przed włamaniem","methodology_en":"Burglary protection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zabezpieczenie przed włamaniem","reference":"PN-91/B-94408 pkt. 3 PN-91/B-94400 pkt. 5.4 i 5.5","norm_bases":["PN-91/B-94408 pkt. 3 PN-91/B-94400 pkt. 5.4 i 5.5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamki i zaczepy Zabezpieczenie przed włamaniem PN-91/B-94408 pkt. 3 PN-91/B-94400 pkt. 5.4 i 5.5 Zamki i zaczepy Zabezpieczenie przed wlamaniem PN-91/B-94408 pkt. 3 PN-91/B-94400 pkt. 5.4 i 5.5","categories":["other"],"row_index":288,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Locks and strikes Burglary protection PN-91/B-94408 pkt. 3 PN-91/B-94400 pkt. 5.4 i 5.5","search_zh":"锁具与锁扣板 PN-91/B-94408 pkt. 3 PN-91/B-94400 pkt. 5.4 i 5.5","test_object_zh":"锁具与锁扣板"},{"_id":"6a5a55f19af9f73f38251035","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamki i zaczepy","test_object_en":"Locks and strikes","methodology":"Wytrzymałość elementów zamka Zakres: (0 - 100) kN","methodology_en":"Strength of lock components Range: (0 - 100) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elementów zamka Zakres: (0 - 100) kN","reference":"PN-EN 12209:2005+AC:2006 pkt. 6.2","norm_bases":["PN-EN 12209:2005+AC:2006 pkt. 6.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamki i zaczepy Wytrzymałość elementów zamka Zakres: (0 - 100) kN PN-EN 12209:2005+AC:2006 pkt. 6.2 Zamki i zaczepy Wytrzymalosc elementow zamka Zakres: (0 - 100) kN PN-EN 12209:2005+AC:2006 pkt. 6.2","categories":["other"],"row_index":289,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Locks and strikes Strength of lock components Range: (0 - 100) kN PN-EN 12209:2005+AC:2006 pkt. 6.2","search_zh":"锁具与锁扣板 PN-EN 12209:2005+AC:2006 pkt. 6.2","test_object_zh":"锁具与锁扣板"},{"_id":"6a5a55f19af9f73f38251036","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamki i zaczepy elektromechaniczne","test_object_en":"Electromechanical locks and strikes","methodology":"Wytrzymałość elementów zamka Zakres: (0 - 100) kN","methodology_en":"Strength of lock components Range: (0 - 100) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elementów zamka Zakres: (0 - 100) kN","reference":"PN-EN 12209:2005+AC:2006 p. 6.8","norm_bases":["PN-EN 12209:2005+AC:2006 p. 6.8"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamki i zaczepy elektromechaniczne Wytrzymałość elementów zamka Zakres: (0 - 100) kN PN-EN 12209:2005+AC:2006 p. 6.8 Zamki i zaczepy elektromechaniczne Wytrzymalosc elementow zamka Zakres: (0 - 100) kN PN-EN 12209:2005+AC:2006 p. 6.8","categories":["other"],"row_index":290,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electromechanical locks and strikes Strength of lock components Range: (0 - 100) kN PN-EN 12209:2005+AC:2006 p. 6.8"},{"_id":"6a5a55f19af9f73f38251037","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu","test_object_en":"Windows including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated","methodology":"Przepuszczalność powietrza przy określonej różnicy ciśnień","methodology_en":"Air permeability at a specified pressure difference","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność powietrza przy określonej różnicy ciśnień","reference":"ASTM E283/E283M-19","norm_bases":["ASTM E283/E283M-19"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu Przepuszczalność powietrza przy określonej różnicy ciśnień ASTM E283/E283M-19 Okna w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane recznie lub za pomoca napedu Przepuszczalnosc powietrza przy okreslonej roznicy cisnien ASTM E283/E283M-19","categories":["construction"],"row_index":291,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated Air permeability at a specified pressure difference ASTM E283/E283M-19","search_zh":"窗，其中包括：－ 阳台门，－ 屋面窗，－ 门窗组合，－ 类似结构，－ 手动或带驱动装置操作 规定压差下的透气性 ASTM E283/E283M-19","test_object_zh":"窗，其中包括：－ 阳台门，－ 屋面窗，－ 门窗组合，－ 类似结构，－ 手动或带驱动装置操作","methodology_zh":"规定压差下的透气性"},{"_id":"6a5a55f19af9f73f38251038","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu","test_object_en":"Windows including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated","methodology":"Siły operacyjne","methodology_en":"Operating forces","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siły operacyjne","reference":"AAMA/WDMA/CSA 101/I.S.2/A440:22 ASTM E2068-00(2022)","norm_bases":["AAMA/WDMA/CSA 101/I.S.2/A440:22 ASTM E2068-00(2022)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu Siły operacyjne AAMA/WDMA/CSA 101/I.S.2/A440:22 ASTM E2068-00(2022) Okna w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane recznie lub za pomoca napedu Sily operacyjne AAMA/WDMA/CSA 101/I.S.2/A440:22 ASTM E2068-00(2022)","categories":["construction"],"row_index":292,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated Operating forces AAMA/WDMA/CSA 101/I.S.2/A440:22 ASTM E2068-00(2022)","methodology_zh":"操作力","search_zh":"窗，其中包括：－ 阳台门，－ 屋面窗，－ 门窗组合，－ 类似结构，－ 手动或带驱动装置操作 操作力 AAMA/WDMA/CSA 101/I.S.2/A440:22 ASTM E2068-00(2022)","test_object_zh":"窗，其中包括：－ 阳台门，－ 屋面窗，－ 门窗组合，－ 类似结构，－ 手动或带驱动装置操作"},{"_id":"6a5a55f19af9f73f38251039","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu","test_object_en":"Windows including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated","methodology":"Sztywność i wytrzymałość przy obciążeniu ciśnieniem statycznym","methodology_en":"Stiffness and strength under static pressure load","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sztywność i wytrzymałość przy obciążeniu ciśnieniem statycznym","reference":"ASTM E330/E330M-14(2021)","norm_bases":["ASTM E330/E330M-14(2021)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu Sztywność i wytrzymałość przy obciążeniu ciśnieniem statycznym ASTM E330/E330M-14(2021) Okna w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane recznie lub za pomoca napedu Sztywnosc i wytrzymalosc przy obciazeniu cisnieniem statycznym ASTM E330/E330M-14(2021)","categories":["construction"],"row_index":293,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated Stiffness and strength under static pressure load ASTM E330/E330M-14(2021)","search_zh":"窗，其中包括：－ 阳台门，－ 屋面窗，－ 门窗组合，－ 类似结构，－ 手动或带驱动装置操作 静压荷载下的刚度与强度 ASTM E330/E330M-14(2021)","test_object_zh":"窗，其中包括：－ 阳台门，－ 屋面窗，－ 门窗组合，－ 类似结构，－ 手动或带驱动装置操作","methodology_zh":"静压荷载下的刚度与强度"},{"_id":"6a5a55f19af9f73f3825103a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu","test_object_en":"Windows including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated","methodology":"Wodoszczelność przy cyklicznej statycznej różnicy ciśnień","methodology_en":"Watertightness under cyclic static pressure difference","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność przy cyklicznej statycznej różnicy ciśnień","reference":"ASTM E547-00(2016)","norm_bases":["ASTM E547-00(2016)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu Wodoszczelność przy cyklicznej statycznej różnicy ciśnień ASTM E547-00(2016) Okna w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane recznie lub za pomoca napedu Wodoszczelnosc przy cyklicznej statycznej roznicy cisnien ASTM E547-00(2016)","categories":["construction"],"row_index":294,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated Watertightness under cyclic static pressure difference ASTM E547-00(2016)","search_zh":"窗，其中包括：－ 阳台门，－ 屋面窗，－ 门窗组合，－ 类似结构，－ 手动或带驱动装置操作 循环静压差下的水密性 ASTM E547-00(2016)","test_object_zh":"窗，其中包括：－ 阳台门，－ 屋面窗，－ 门窗组合，－ 类似结构，－ 手动或带驱动装置操作","methodology_zh":"循环静压差下的水密性"},{"_id":"6a5a55f19af9f73f3825103b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu","test_object_en":"Windows including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated","methodology":"Wodoszczelność przy statycznej różnicy ciśnień","methodology_en":"Watertightness under static pressure difference","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność przy statycznej różnicy ciśnień","reference":"ASTM E331-00(2023)","norm_bases":["ASTM E331-00(2023)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu Wodoszczelność przy statycznej różnicy ciśnień ASTM E331-00(2023) Okna w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane recznie lub za pomoca napedu Wodoszczelnosc przy statycznej roznicy cisnien ASTM E331-00(2023)","categories":["construction"],"row_index":295,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated Watertightness under static pressure difference ASTM E331-00(2023)","search_zh":"窗，其中包括：－ 阳台门，－ 屋面窗，－ 门窗组合，－ 类似结构，－ 手动或带驱动装置操作 ASTM E331-00(2023)","test_object_zh":"窗，其中包括：－ 阳台门，－ 屋面窗，－ 门窗组合，－ 类似结构，－ 手动或带驱动装置操作"},{"_id":"6a5a55f19af9f73f3825103c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Świetliki: - pasmowe, - punktowe, - inne","test_object_en":"Rooflights: - continuous, - point, - other","methodology":"Przepuszczalność powietrza przy określonej różnicy ciśnień","methodology_en":"Air permeability at a specified pressure difference","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność powietrza przy określonej różnicy ciśnień","reference":"ASTM E283/E283M-19","norm_bases":["ASTM E283/E283M-19"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Świetliki: - pasmowe, - punktowe, - inne Przepuszczalność powietrza przy określonej różnicy ciśnień ASTM E283/E283M-19 Swietliki: - pasmowe, - punktowe, - inne Przepuszczalnosc powietrza przy okreslonej roznicy cisnien ASTM E283/E283M-19","categories":["other"],"row_index":296,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooflights: - continuous, - point, - other Air permeability at a specified pressure difference ASTM E283/E283M-19","search_zh":"采光天窗：－ 带形，－ 点式，－ 其他 规定压差下的透气性 ASTM E283/E283M-19","test_object_zh":"采光天窗：－ 带形，－ 点式，－ 其他","methodology_zh":"规定压差下的透气性"},{"_id":"6a5a55f19af9f73f3825103d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Świetliki: - pasmowe, - punktowe, - inne","test_object_en":"Rooflights: - continuous, - point, - other","methodology":"Siły operacyjne","methodology_en":"Operating forces","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siły operacyjne","reference":"AAMA/WDMA/CSA 101/I.S.2/A440:22 ASTM E2068-00(2022)","norm_bases":["AAMA/WDMA/CSA 101/I.S.2/A440:22 ASTM E2068-00(2022)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Świetliki: - pasmowe, - punktowe, - inne Siły operacyjne AAMA/WDMA/CSA 101/I.S.2/A440:22 ASTM E2068-00(2022) Swietliki: - pasmowe, - punktowe, - inne Sily operacyjne AAMA/WDMA/CSA 101/I.S.2/A440:22 ASTM E2068-00(2022)","categories":["other"],"row_index":297,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooflights: - continuous, - point, - other Operating forces AAMA/WDMA/CSA 101/I.S.2/A440:22 ASTM E2068-00(2022)","methodology_zh":"操作力","search_zh":"采光天窗：－ 带形，－ 点式，－ 其他 操作力 AAMA/WDMA/CSA 101/I.S.2/A440:22 ASTM E2068-00(2022)","test_object_zh":"采光天窗：－ 带形，－ 点式，－ 其他"},{"_id":"6a5a55f19af9f73f3825103e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Świetliki: - pasmowe, - punktowe, - inne","test_object_en":"Rooflights: - continuous, - point, - other","methodology":"Sztywność i wytrzymałość przy obciążeniu ciśnieniem statycznym","methodology_en":"Stiffness and strength under static pressure load","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sztywność i wytrzymałość przy obciążeniu ciśnieniem statycznym","reference":"ASTM E330/E330M-14(2021)","norm_bases":["ASTM E330/E330M-14(2021)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Świetliki: - pasmowe, - punktowe, - inne Sztywność i wytrzymałość przy obciążeniu ciśnieniem statycznym ASTM E330/E330M-14(2021) Swietliki: - pasmowe, - punktowe, - inne Sztywnosc i wytrzymalosc przy obciazeniu cisnieniem statycznym ASTM E330/E330M-14(2021)","categories":["other"],"row_index":298,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooflights: - continuous, - point, - other Stiffness and strength under static pressure load ASTM E330/E330M-14(2021)","search_zh":"采光天窗：－ 带形，－ 点式，－ 其他 静压荷载下的刚度与强度 ASTM E330/E330M-14(2021)","test_object_zh":"采光天窗：－ 带形，－ 点式，－ 其他","methodology_zh":"静压荷载下的刚度与强度"},{"_id":"6a5a55f19af9f73f3825103f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Świetliki: - pasmowe, - punktowe, - inne","test_object_en":"Rooflights: - continuous, - point, - other","methodology":"Wodoszczelność przy cyklicznej statycznej różnicy ciśnień","methodology_en":"Watertightness under cyclic static pressure difference","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność przy cyklicznej statycznej różnicy ciśnień","reference":"ASTM E547-00(2016)","norm_bases":["ASTM E547-00(2016)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Świetliki: - pasmowe, - punktowe, - inne Wodoszczelność przy cyklicznej statycznej różnicy ciśnień ASTM E547-00(2016) Swietliki: - pasmowe, - punktowe, - inne Wodoszczelnosc przy cyklicznej statycznej roznicy cisnien ASTM E547-00(2016)","categories":["other"],"row_index":299,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooflights: - continuous, - point, - other Watertightness under cyclic static pressure difference ASTM E547-00(2016)","search_zh":"采光天窗：－ 带形，－ 点式，－ 其他 循环静压差下的水密性 ASTM E547-00(2016)","test_object_zh":"采光天窗：－ 带形，－ 点式，－ 其他","methodology_zh":"循环静压差下的水密性"},{"_id":"6a5a55f19af9f73f38251040","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Świetliki: - pasmowe, - punktowe, - inne","test_object_en":"Rooflights: - continuous, - point, - other","methodology":"Wodoszczelność przy statycznej różnicy ciśnień","methodology_en":"Watertightness under static pressure difference","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność przy statycznej różnicy ciśnień","reference":"ASTM E331-00(2023)","norm_bases":["ASTM E331-00(2023)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Świetliki: - pasmowe, - punktowe, - inne Wodoszczelność przy statycznej różnicy ciśnień ASTM E331-00(2023) Swietliki: - pasmowe, - punktowe, - inne Wodoszczelnosc przy statycznej roznicy cisnien ASTM E331-00(2023)","categories":["other"],"row_index":300,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooflights: - continuous, - point, - other Watertightness under static pressure difference ASTM E331-00(2023)","search_zh":"采光天窗：－ 带形，－ 点式，－ 其他 ASTM E331-00(2023)","test_object_zh":"采光天窗：－ 带形，－ 点式，－ 其他"},{"_id":"6a5a55f19af9f73f38251041","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Blachy metalowe samonośne E","test_object_en":"Self-supporting metal sheets E","methodology":"Granica plastyczności","methodology_en":"Yield strength","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Granica plastyczności","reference":"PN-EN 14782","norm_bases":["PN-EN 14782"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Blachy metalowe samonośne E Granica plastyczności PN-EN 14782 Blachy metalowe samonosne E Granica plastycznosci PN-EN 14782","categories":["materials"],"row_index":301,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Self-supporting metal sheets E Yield strength PN-EN 14782","methodology_zh":"屈服强度","search_zh":"自承式金属板 E 屈服强度 PN-EN 14782","test_object_zh":"自承式金属板 E"},{"_id":"6a5a55f19af9f73f38251042","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Blachy metalowe samonośne E","test_object_en":"Self-supporting metal sheets E","methodology":"Grubość","methodology_en":"Thickness","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Grubość","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Blachy metalowe samonośne E Grubość Blachy metalowe samonosne E Grubosc","categories":["materials"],"row_index":302,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Self-supporting metal sheets E Thickness","methodology_zh":"厚度","search_zh":"自承式金属板 E 厚度","test_object_zh":"自承式金属板 E"},{"_id":"6a5a55f19af9f73f38251043","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Blachy metalowe samonośne E","test_object_en":"Self-supporting metal sheets E","methodology":"Paroprzepuszczalność i przepuszczalność powietrza","methodology_en":"Water vapour permeability and air permeability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Paroprzepuszczalność i przepuszczalność powietrza","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Blachy metalowe samonośne E Paroprzepuszczalność i przepuszczalność powietrza Blachy metalowe samonosne E Paroprzepuszczalnosc i przepuszczalnosc powietrza","categories":["materials"],"row_index":303,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Self-supporting metal sheets E Water vapour permeability and air permeability","search_zh":"自承式金属板 E","test_object_zh":"自承式金属板 E"},{"_id":"6a5a55f19af9f73f38251044","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Blachy metalowe samonośne E","test_object_en":"Self-supporting metal sheets E","methodology":"Wymiary geometryczne liniowe","methodology_en":"Linear geometric dimensions","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary geometryczne liniowe","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Blachy metalowe samonośne E Wymiary geometryczne liniowe Blachy metalowe samonosne E Wymiary geometryczne liniowe","categories":["materials"],"row_index":304,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Self-supporting metal sheets E Linear geometric dimensions","methodology_zh":"几何线性尺寸","search_zh":"自承式金属板 E 几何线性尺寸","test_object_zh":"自承式金属板 E"},{"_id":"6a5a55f19af9f73f38251045","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Blachy metalowe samonośne E","test_object_en":"Self-supporting metal sheets E","methodology":"Trwałość","methodology_en":"Durability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Blachy metalowe samonośne E Trwałość Blachy metalowe samonosne E Trwalosc","categories":["materials"],"row_index":305,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Self-supporting metal sheets E Durability","methodology_zh":"耐久性","search_zh":"自承式金属板 E 耐久性","test_object_zh":"自承式金属板 E"},{"_id":"6a5a55f19af9f73f38251046","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Blachy metalowe samonośne E","test_object_en":"Self-supporting metal sheets E","methodology":"Wodoszczelność","methodology_en":"Watertightness","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Blachy metalowe samonośne E Wodoszczelność Blachy metalowe samonosne E Wodoszczelnosc","categories":["materials"],"row_index":306,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Self-supporting metal sheets E Watertightness","methodology_zh":"不透水性","search_zh":"自承式金属板 E 不透水性","test_object_zh":"自承式金属板 E"},{"_id":"6a5a55f19af9f73f38251047","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Blachy metalowe samonośne E","test_object_en":"Self-supporting metal sheets E","methodology":"Wytrzymałość na obciążenia skupione","methodology_en":"Resistance to concentrated loads","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na obciążenia skupione","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Blachy metalowe samonośne E Wytrzymałość na obciążenia skupione Blachy metalowe samonosne E Wytrzymalosc na obciazenia skupione","categories":["materials"],"row_index":307,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Self-supporting metal sheets E Resistance to concentrated loads","search_zh":"自承式金属板 E","test_object_zh":"自承式金属板 E"},{"_id":"6a5a55f19af9f73f38251048","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Bramy E","test_object_en":"Gates E","methodology":"Próg wykrywania +","methodology_en":"Detection threshold +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Próg wykrywania +","reference":"PN-EN 12978","norm_bases":["PN-EN 12978"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bramy E Próg wykrywania + PN-EN 12978 Bramy E Prog wykrywania + PN-EN 12978","categories":["other"],"row_index":308,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gates E Detection threshold + PN-EN 12978","search_zh":"大门 E PN-EN 12978","test_object_zh":"大门 E"},{"_id":"6a5a55f19af9f73f38251049","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Bramy E","test_object_en":"Gates E","methodology":"Odporność na obciążenie wiatrem +","methodology_en":"Resistance to wind load +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenie wiatrem +","reference":"PN-EN 12444 „N”","norm_bases":["PN-EN 12444 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bramy E Odporność na obciążenie wiatrem + PN-EN 12444 „N” Bramy E Odpornosc na obciazenie wiatrem + PN-EN 12444 „N”","categories":["other"],"row_index":309,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gates E Resistance to wind load + PN-EN 12444 „N”","search_zh":"大门 E 抗风荷载性 + PN-EN 12444 „N”","test_object_zh":"大门 E","methodology_zh":"抗风荷载性 +"},{"_id":"6a5a55f19af9f73f3825104a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Bramy E","test_object_en":"Gates E","methodology":"Odporność na przenikanie wody +","methodology_en":"Resistance to water penetration +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na przenikanie wody +","reference":"PN-EN 12489 „N”","norm_bases":["PN-EN 12489 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bramy E Odporność na przenikanie wody + PN-EN 12489 „N” Bramy E Odpornosc na przenikanie wody + PN-EN 12489 „N”","categories":["water"],"row_index":310,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gates E Resistance to water penetration + PN-EN 12489 „N”","search_zh":"大门 E 抗水渗透性 + PN-EN 12489 „N”","test_object_zh":"大门 E","methodology_zh":"抗水渗透性 +"},{"_id":"6a5a55f19af9f73f3825104b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Bramy E","test_object_en":"Gates E","methodology":"Przepuszczalność powietrza +","methodology_en":"Air permeability +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność powietrza +","reference":"PN-EN 12427 „N”","norm_bases":["PN-EN 12427 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bramy E Przepuszczalność powietrza + PN-EN 12427 „N” Bramy E Przepuszczalnosc powietrza + PN-EN 12427 „N”","categories":["other"],"row_index":311,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gates E Air permeability + PN-EN 12427 „N”","search_zh":"大门 E 透气性 + PN-EN 12427 „N”","test_object_zh":"大门 E","methodology_zh":"透气性 +"},{"_id":"6a5a55f19af9f73f3825104c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Bramy E","test_object_en":"Gates E","methodology":"Siła na krawędziach +","methodology_en":"Force at the edges +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła na krawędziach +","reference":"PN-EN 12445 „N”","norm_bases":["PN-EN 12445 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bramy E Siła na krawędziach + PN-EN 12445 „N” Bramy E Sila na krawedziach + PN-EN 12445 „N”","categories":["other"],"row_index":312,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gates E Force at the edges + PN-EN 12445 „N”","search_zh":"大门 E PN-EN 12445 „N”","test_object_zh":"大门 E"},{"_id":"6a5a55f19af9f73f3825104d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Bramy E","test_object_en":"Gates E","methodology":"Trwałość +","methodology_en":"Durability +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość +","reference":"PN-EN 12605 „N” PN-EN 12604 „N”","norm_bases":["PN-EN 12605 „N” PN-EN 12604 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bramy E Trwałość + PN-EN 12605 „N” PN-EN 12604 „N” Bramy E Trwalosc + PN-EN 12605 „N” PN-EN 12604 „N”","categories":["other"],"row_index":313,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gates E Durability + PN-EN 12605 „N” PN-EN 12604 „N”","search_zh":"大门 E 耐久性 + PN-EN 12605 „N” PN-EN 12604 „N”","test_object_zh":"大门 E","methodology_zh":"耐久性 +"},{"_id":"6a5a55f19af9f73f3825104e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Bramy E","test_object_en":"Gates E","methodology":"Funkcjonalność +","methodology_en":"Functionality +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Funkcjonalność +","reference":"PN-EN 12605 „N” PN-EN 12604 „N”","norm_bases":["PN-EN 12605 „N” PN-EN 12604 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bramy E Funkcjonalność + PN-EN 12605 „N” PN-EN 12604 „N” Bramy E Funkcjonalnosc + PN-EN 12605 „N” PN-EN 12604 „N”","categories":["other"],"row_index":314,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gates E Functionality + PN-EN 12605 „N” PN-EN 12604 „N”","search_zh":"大门 E 功能性 + PN-EN 12605 „N” PN-EN 12604 „N”","test_object_zh":"大门 E","methodology_zh":"功能性 +"},{"_id":"6a5a55f19af9f73f3825104f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Bramy E","test_object_en":"Gates E","methodology":"Wykonanie +","methodology_en":"Workmanship +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wykonanie +","reference":"PN-EN 12605 „N” PN-EN 12604 „N”","norm_bases":["PN-EN 12605 „N” PN-EN 12604 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bramy E Wykonanie + PN-EN 12605 „N” PN-EN 12604 „N” Bramy E Wykonanie + PN-EN 12605 „N” PN-EN 12604 „N”","categories":["other"],"row_index":315,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gates E Workmanship + PN-EN 12605 „N” PN-EN 12604 „N”","search_zh":"大门 E 制作工艺 + PN-EN 12605 „N” PN-EN 12604 „N”","test_object_zh":"大门 E","methodology_zh":"制作工艺 +"},{"_id":"6a5a55f19af9f73f38251050","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Bramy E","test_object_en":"Gates E","methodology":"Bezpieczeństwo użytkowania +","methodology_en":"Safety in use +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Bezpieczeństwo użytkowania +","reference":"PN-EN 12445","norm_bases":["PN-EN 12445"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bramy E Bezpieczeństwo użytkowania + PN-EN 12445 Bramy E Bezpieczenstwo uzytkowania + PN-EN 12445","categories":["other"],"row_index":316,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gates E Safety in use + PN-EN 12445","search_zh":"大门 E PN-EN 12445","test_object_zh":"大门 E"},{"_id":"6a5a55f19af9f73f38251051","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Odporność na obciążenia wiatrem +","methodology_en":"Resistance to wind loads +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenia wiatrem +","reference":"PN-EN 12211 „N”","norm_bases":["PN-EN 12211 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Odporność na obciążenia wiatrem + PN-EN 12211 „N” Drzwi, zespoly drzwiowe, skrzydla, oscieznice E w tym m.in.: - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - uruchamiane recznie i z napedami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Odpornosc na obciazenia wiatrem + PN-EN 12211 „N”","categories":["other"],"row_index":317,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes Resistance to wind loads + PN-EN 12211 „N”","search_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 PN-EN 12211 „N”","test_object_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用"},{"_id":"6a5a55f19af9f73f38251052","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Odporność na uderzenie ciałem miękkim i ciężkim +","methodology_en":"Resistance to soft and heavy body impact +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie ciałem miękkim i ciężkim +","reference":"PN-EN 13049 „N” PN-EN 14351-2 + PN-EN 12600","norm_bases":["PN-EN 13049 „N” PN-EN 14351-2 + PN-EN 12600"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Odporność na uderzenie ciałem miękkim i ciężkim + PN-EN 13049 „N” PN-EN 14351-2 + PN-EN 12600 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E w tym m.in.: - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - uruchamiane recznie i z napedami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Odpornosc na uderzenie cialem miekkim i ciezkim + PN-EN 13049 „N” PN-EN 14351-2 + PN-EN 12600","categories":["other"],"row_index":318,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes Resistance to soft and heavy body impact + PN-EN 13049 „N” PN-EN 14351-2 + PN-EN 12600","search_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 软体与硬重物撞击抗力 + PN-EN 13049 „N” PN-EN 14351-2 + PN-EN 12600","test_object_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用","methodology_zh":"软体与硬重物撞击抗力 +"},{"_id":"6a5a55f19af9f73f38251053","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Odporność na uderzenie ciałem miękkim i ciężkim","methodology_en":"Resistance to soft and heavy body impact","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie ciałem miękkim i ciężkim","reference":"PN-EN 949","norm_bases":["PN-EN 949"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Odporność na uderzenie ciałem miękkim i ciężkim PN-EN 949 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E w tym m.in.: - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - uruchamiane recznie i z napedami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Odpornosc na uderzenie cialem miekkim i ciezkim PN-EN 949","categories":["other"],"row_index":319,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes Resistance to soft and heavy body impact PN-EN 949","search_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 软体与硬重物撞击抗力 PN-EN 949","test_object_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用","methodology_zh":"软体与硬重物撞击抗力"},{"_id":"6a5a55f19af9f73f38251054","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Odporność na włamanie - próba włamania ręcznego","methodology_en":"Burglar resistance - manual burglary attempt test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na włamanie - próba włamania ręcznego","reference":"PN-EN 1630","norm_bases":["PN-EN 1630"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Odporność na włamanie - próba włamania ręcznego PN-EN 1630 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E w tym m.in.: - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - uruchamiane recznie i z napedami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Odpornosc na wlamanie - proba wlamania recznego PN-EN 1630","categories":["other"],"row_index":320,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes Burglar resistance - manual burglary attempt test PN-EN 1630","search_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 抗侵入性 － 手工侵入试验 PN-EN 1630","test_object_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用","methodology_zh":"抗侵入性 － 手工侵入试验"},{"_id":"6a5a55f19af9f73f38251055","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Odporność na włamanie przy obciążeniu dynamicznym","methodology_en":"Burglar resistance under dynamic load","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na włamanie przy obciążeniu dynamicznym","reference":"PN-EN 1629","norm_bases":["PN-EN 1629"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Odporność na włamanie przy obciążeniu dynamicznym PN-EN 1629 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E w tym m.in.: - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - uruchamiane recznie i z napedami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Odpornosc na wlamanie przy obciazeniu dynamicznym PN-EN 1629","categories":["other"],"row_index":321,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes Burglar resistance under dynamic load PN-EN 1629","search_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 动荷载下的抗侵入性 PN-EN 1629","test_object_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用","methodology_zh":"动荷载下的抗侵入性"},{"_id":"6a5a55f19af9f73f38251056","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Odporność na włamanie przy obciążeniu statycznym","methodology_en":"Burglar resistance under static loading","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na włamanie przy obciążeniu statycznym","reference":"PN-EN 1628","norm_bases":["PN-EN 1628"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Odporność na włamanie przy obciążeniu statycznym PN-EN 1628 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E w tym m.in.: - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - uruchamiane recznie i z napedami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Odpornosc na wlamanie przy obciazeniu statycznym PN-EN 1628","categories":["other"],"row_index":322,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes Burglar resistance under static loading PN-EN 1628","search_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 静荷载下的抗侵入性 PN-EN 1628","test_object_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用","methodology_zh":"静荷载下的抗侵入性"},{"_id":"6a5a55f19af9f73f38251057","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Przepuszczalność powietrza +","methodology_en":"Air permeability +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność powietrza +","reference":"PN-EN 1026 „N” PN-EN 14351-2","norm_bases":["PN-EN 1026 „N” PN-EN 14351-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Przepuszczalność powietrza + PN-EN 1026 „N” PN-EN 14351-2 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E w tym m.in.: - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - uruchamiane recznie i z napedami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Przepuszczalnosc powietrza + PN-EN 1026 „N” PN-EN 14351-2","categories":["other"],"row_index":323,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes Air permeability + PN-EN 1026 „N” PN-EN 14351-2","search_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 透气性 + PN-EN 1026 „N” PN-EN 14351-2","test_object_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用","methodology_zh":"透气性 +"},{"_id":"6a5a55f19af9f73f38251058","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Wodoszczelność +","methodology_en":"Watertightness +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność +","reference":"PN-EN 1027 „N”","norm_bases":["PN-EN 1027 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Wodoszczelność + PN-EN 1027 „N” Drzwi, zespoly drzwiowe, skrzydla, oscieznice E w tym m.in.: - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - uruchamiane recznie i z napedami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Wodoszczelnosc + PN-EN 1027 „N”","categories":["other"],"row_index":324,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes Watertightness + PN-EN 1027 „N”","search_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 水密性 + PN-EN 1027 „N”","test_object_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用","methodology_zh":"水密性 +"},{"_id":"6a5a55f19af9f73f38251059","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Zdolność do zwolnienia Zakres: (0 - 5000) N","methodology_en":"Release capability Range: (0 - 5000) N","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność do zwolnienia Zakres: (0 - 5000) N","reference":"PN-EN 1125 PN-EN 179 PN-EN 14351-2","norm_bases":["PN-EN 1125 PN-EN 179 PN-EN 14351-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Zdolność do zwolnienia Zakres: (0 - 5000) N PN-EN 1125 PN-EN 179 PN-EN 14351-2 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E w tym m.in.: - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - uruchamiane recznie i z napedami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Zdolnosc do zwolnienia Zakres: (0 - 5000) N PN-EN 1125 PN-EN 179 PN-EN 14351-2","categories":["other"],"row_index":325,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes Release capability Range: (0 - 5000) N PN-EN 1125 PN-EN 179 PN-EN 14351-2","search_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 PN-EN 1125 PN-EN 179 PN-EN 14351-2","test_object_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用"},{"_id":"6a5a55f19af9f73f3825105a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Wysokość +","methodology_en":"Height +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wysokość +","reference":"PN-EN 14351-2","norm_bases":["PN-EN 14351-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Wysokość + PN-EN 14351-2 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E w tym m.in.: - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - uruchamiane recznie i z napedami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Wysokosc + PN-EN 14351-2","categories":["other"],"row_index":326,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes Height + PN-EN 14351-2","search_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 高度 + PN-EN 14351-2","test_object_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用","methodology_zh":"高度 +"},{"_id":"6a5a55f19af9f73f3825105b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Szerokość +","methodology_en":"Width +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szerokość +","reference":"PN-EN 14351-2","norm_bases":["PN-EN 14351-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Szerokość + PN-EN 14351-2 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E w tym m.in.: - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - uruchamiane recznie i z napedami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Szerokosc + PN-EN 14351-2","categories":["other"],"row_index":327,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes Width + PN-EN 14351-2","search_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 PN-EN 14351-2","test_object_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用"},{"_id":"6a5a55f19af9f73f3825105c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Wymiary geometryczne liniowe","methodology_en":"Linear geometric dimensions","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary geometryczne liniowe","reference":"PN-EN 951","norm_bases":["PN-EN 951"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Wymiary geometryczne liniowe PN-EN 951 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E w tym m.in.: - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - uruchamiane recznie i z napedami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Wymiary geometryczne liniowe PN-EN 951","categories":["other"],"row_index":328,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes Linear geometric dimensions PN-EN 951","search_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 几何线性尺寸 PN-EN 951","test_object_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用","methodology_zh":"几何线性尺寸"},{"_id":"6a5a55f19af9f73f3825105d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Odporność na obciążenia pionowe","methodology_en":"Resistance to vertical loads","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenia pionowe","reference":"PN-EN 947","norm_bases":["PN-EN 947"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Odporność na obciążenia pionowe PN-EN 947 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E w tym m.in.: - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - uruchamiane recznie i z napedami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Odpornosc na obciazenia pionowe PN-EN 947","categories":["other"],"row_index":329,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes Resistance to vertical loads PN-EN 947","search_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 PN-EN 947","test_object_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用"},{"_id":"6a5a55f19af9f73f3825105e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Odporność na obciążenia statyczne prostopadłe do płaszczyzny skrzydła","methodology_en":"Resistance to static loads perpendicular to the plane of the leaf","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenia statyczne prostopadłe do płaszczyzny skrzydła","reference":"PN-87/B-06077","norm_bases":["PN-87/B-06077"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Odporność na obciążenia statyczne prostopadłe do płaszczyzny skrzydła PN-87/B-06077 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E w tym m.in.: - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - uruchamiane recznie i z napedami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Odpornosc na obciazenia statyczne prostopadle do plaszczyzny skrzydla PN-87/B-06077","categories":["other"],"row_index":330,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes Resistance to static loads perpendicular to the plane of the leaf PN-87/B-06077","search_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 PN-87/B-06077","test_object_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用"},{"_id":"6a5a55f19af9f73f3825105f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Odporność na wielokrotne otwieranie i zamykanie","methodology_en":"Resistance to repeated opening and closing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na wielokrotne otwieranie i zamykanie","reference":"PN-EN 1191","norm_bases":["PN-EN 1191"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Odporność na wielokrotne otwieranie i zamykanie PN-EN 1191 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E w tym m.in.: - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - uruchamiane recznie i z napedami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Odpornosc na wielokrotne otwieranie i zamykanie PN-EN 1191","categories":["other"],"row_index":331,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes Resistance to repeated opening and closing PN-EN 1191","search_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 反复启闭的耐受性 PN-EN 1191","test_object_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用","methodology_zh":"反复启闭的耐受性"},{"_id":"6a5a55f19af9f73f38251060","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Odporność na wstrząsy","methodology_en":"Shock resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na wstrząsy","reference":"PN-88/B-06079","norm_bases":["PN-88/B-06079"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Odporność na wstrząsy PN-88/B-06079 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E w tym m.in.: - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - uruchamiane recznie i z napedami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Odpornosc na wstrzasy PN-88/B-06079","categories":["other"],"row_index":332,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes Shock resistance PN-88/B-06079","search_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 耐振动性 PN-88/B-06079","test_object_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用","methodology_zh":"耐振动性"},{"_id":"6a5a55f19af9f73f38251061","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Prostokątność","methodology_en":"Squareness","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Prostokątność","reference":"PN-EN 951","norm_bases":["PN-EN 951"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Prostokątność PN-EN 951 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E w tym m.in.: - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - uruchamiane recznie i z napedami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Prostokatnosc PN-EN 951","categories":["other"],"row_index":333,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes Squareness PN-EN 951","search_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 直角度 PN-EN 951","test_object_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用","methodology_zh":"直角度"},{"_id":"6a5a55f19af9f73f38251062","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Siła, moment obrotowy Moment obrotowy Zakres: (0 - 350) Nm","methodology_en":"Force, torque Torque Range: (0 - 350) Nm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła, moment obrotowy Moment obrotowy Zakres: (0 - 350) Nm","reference":"PN-EN 12046-2","norm_bases":["PN-EN 12046-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Siła, moment obrotowy Moment obrotowy Zakres: (0 - 350) Nm PN-EN 12046-2 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E w tym m.in.: - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - uruchamiane recznie i z napedami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Sila, moment obrotowy Moment obrotowy Zakres: (0 - 350) Nm PN-EN 12046-2","categories":["other"],"row_index":334,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes Force, torque Torque Range: (0 - 350) Nm PN-EN 12046-2","search_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 PN-EN 12046-2","test_object_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用"},{"_id":"6a5a55f19af9f73f38251063","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Siły operacyjne Zakres: (0 - 5000) N","methodology_en":"Operating forces Range: (0 - 5000) N","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siły operacyjne Zakres: (0 - 5000) N","reference":"PN-EN 12046-2 „N”","norm_bases":["PN-EN 12046-2 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Siły operacyjne Zakres: (0 - 5000) N PN-EN 12046-2 „N” Drzwi, zespoly drzwiowe, skrzydla, oscieznice E w tym m.in.: - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - uruchamiane recznie i z napedami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Sily operacyjne Zakres: (0 - 5000) N PN-EN 12046-2 „N”","categories":["other"],"row_index":335,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes Operating forces Range: (0 - 5000) N PN-EN 12046-2 „N”","search_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 PN-EN 12046-2 „N”","test_object_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用"},{"_id":"6a5a55f19af9f73f38251064","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Wytrzymałość na skręcenie statyczne","methodology_en":"Static torsional strength","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na skręcenie statyczne","reference":"PN-EN 948 „N”","norm_bases":["PN-EN 948 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Wytrzymałość na skręcenie statyczne PN-EN 948 „N” Drzwi, zespoly drzwiowe, skrzydla, oscieznice E w tym m.in.: - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - uruchamiane recznie i z napedami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Wytrzymalosc na skrecenie statyczne PN-EN 948 „N”","categories":["other"],"row_index":336,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes Static torsional strength PN-EN 948 „N”","search_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 PN-EN 948 „N”","test_object_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用"},{"_id":"6a5a55f19af9f73f38251065","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Nośność urządzeń zabezpieczających","methodology_en":"Load-bearing capacity of safety devices","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność urządzeń zabezpieczających","reference":"PN-EN 14351-1 PN-EN 948 „N”","norm_bases":["PN-EN 14351-1 PN-EN 948 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Nośność urządzeń zabezpieczających PN-EN 14351-1 PN-EN 948 „N” Drzwi, zespoly drzwiowe, skrzydla, oscieznice E w tym m.in.: - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - uruchamiane recznie i z napedami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Nosnosc urzadzen zabezpieczajacych PN-EN 14351-1 PN-EN 948 „N”","categories":["other"],"row_index":337,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes Load-bearing capacity of safety devices PN-EN 14351-1 PN-EN 948 „N”","search_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 安全装置的承载力 PN-EN 14351-1 PN-EN 948 „N”","test_object_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用","methodology_zh":"安全装置的承载力"},{"_id":"6a5a55f19af9f73f38251066","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Odporność na uderzenie ciałem twardym","methodology_en":"Resistance to hard body impact","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie ciałem twardym","reference":"PN-EN 950","norm_bases":["PN-EN 950"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Odporność na uderzenie ciałem twardym PN-EN 950 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E w tym m.in.: - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - uruchamiane recznie i z napedami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Odpornosc na uderzenie cialem twardym PN-EN 950","categories":["other"],"row_index":338,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes Resistance to hard body impact PN-EN 950","search_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 硬物撞击抗力 PN-EN 950","test_object_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用","methodology_zh":"硬物撞击抗力"},{"_id":"6a5a55f19af9f73f38251067","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych","test_object_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes","methodology":"Płaskość ogólna i miejscowa","methodology_en":"Overall and local flatness","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Płaskość ogólna i miejscowa","reference":"PN-EN 952","norm_bases":["PN-EN 952"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi, zespoły drzwiowe, skrzydła, ościeżnice E w tym m.in.: - wewnętrzne i zewnętrzne - rozwierane - przesuwne - harmonijkowe - wahadłowe, - składane - obrotowe - uruchamiane ręcznie i z napędami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Płaskość ogólna i miejscowa PN-EN 952 Drzwi, zespoly drzwiowe, skrzydla, oscieznice E w tym m.in.: - wewnetrzne i zewnetrzne - rozwierane - przesuwne - harmonijkowe - wahadlowe, - skladane - obrotowe - uruchamiane recznie i z napedami - z okuciami przeciwpanicznymi - na drogach ewakuacyjnych Plaskosc ogolna i miejscowa PN-EN 952","categories":["other"],"row_index":339,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors, door sets, leaves, frames E including among others: - internal and external - side-hung - sliding - concertina - swing, - folding - revolving - manually operated and power operated - with panic exit devices - on escape routes Overall and local flatness PN-EN 952","search_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用 PN-EN 952","test_object_zh":"门、门组件、门扇、门框 E，其中包括： — 内门与外门 — 平开 — 推拉 — 折叠式 — 弹簧门 — 折门 — 旋转 — 手动与带驱动装置 — 带防惊慌五金件 — 疏散通道用"},{"_id":"6a5a55f19af9f73f38251068","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Brodziki E","test_object_en":"Shower trays E","methodology":"Odporność na zmiany temperatury","methodology_en":"Resistance to temperature changes","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zmiany temperatury","reference":"PN-EN 14527","norm_bases":["PN-EN 14527"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Brodziki E Odporność na zmiany temperatury PN-EN 14527 Brodziki E Odpornosc na zmiany temperatury PN-EN 14527","categories":["other"],"row_index":340,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Shower trays E Resistance to temperature changes PN-EN 14527","methodology_zh":"耐温度变化性","search_zh":"淋浴盘 E 耐温度变化性 PN-EN 14527","test_object_zh":"淋浴盘 E"},{"_id":"6a5a55f19af9f73f38251069","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Brodziki E","test_object_en":"Shower trays E","methodology":"Odprowadzenie wody","methodology_en":"Water drainage","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odprowadzenie wody","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Brodziki E Odprowadzenie wody Brodziki E Odprowadzenie wody","categories":["water"],"row_index":341,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Shower trays E Water drainage","search_zh":"淋浴盘 E","test_object_zh":"淋浴盘 E"},{"_id":"6a5a55f19af9f73f3825106a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Brodziki E","test_object_en":"Shower trays E","methodology":"Sprawdzenie odporności na odczynniki chemiczne i środki plamiące","methodology_en":"Verification of resistance to chemical reagents and staining agents","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sprawdzenie odporności na odczynniki chemiczne i środki plamiące","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Brodziki E Sprawdzenie odporności na odczynniki chemiczne i środki plamiące Brodziki E Sprawdzenie odpornosci na odczynniki chemiczne i srodki plamiace","categories":["other"],"row_index":342,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Shower trays E Verification of resistance to chemical reagents and staining agents","search_zh":"淋浴盘 E","test_object_zh":"淋浴盘 E"},{"_id":"6a5a55f19af9f73f3825106b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Brodziki E","test_object_en":"Shower trays E","methodology":"Stabilność dna brodzika natryskowego","methodology_en":"Stability of the shower tray base","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stabilność dna brodzika natryskowego","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Brodziki E Stabilność dna brodzika natryskowego Brodziki E Stabilnosc dna brodzika natryskowego","categories":["other"],"row_index":343,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Shower trays E Stability of the shower tray base","search_zh":"淋浴盘 E","test_object_zh":"淋浴盘 E"},{"_id":"6a5a55f19af9f73f3825106c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Brodziki E","test_object_en":"Shower trays E","methodology":"Wymiary geometryczne liniowe","methodology_en":"Linear geometric dimensions","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary geometryczne liniowe","reference":"PN-EN 251","norm_bases":["PN-EN 251"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Brodziki E Wymiary geometryczne liniowe PN-EN 251 Brodziki E Wymiary geometryczne liniowe PN-EN 251","categories":["other"],"row_index":344,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Shower trays E Linear geometric dimensions PN-EN 251","methodology_zh":"几何线性尺寸","search_zh":"淋浴盘 E 几何线性尺寸 PN-EN 251","test_object_zh":"淋浴盘 E"},{"_id":"6a5a55f19af9f73f3825106d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drabiny strychowe (schody) E","test_object_en":"Loft ladders (stairs) E","methodology":"Obciążenie statyczne, obciążenie cykliczne, skręcenie stopnia, wytrzymałość poręczy, wytrzymałość ograniczników, wytrzymałość stopnia, cechy konstrukcyjne","methodology_en":"Static load, cyclic load, step torsion, handrail strength, strength of stops, step strength, design features","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Obciążenie statyczne, obciążenie cykliczne, skręcenie stopnia, wytrzymałość poręczy, wytrzymałość ograniczników, wytrzymałość stopnia, cechy konstrukcyjne","reference":"PN-EN 14975","norm_bases":["PN-EN 14975"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drabiny strychowe (schody) E Obciążenie statyczne, obciążenie cykliczne, skręcenie stopnia, wytrzymałość poręczy, wytrzymałość ograniczników, wytrzymałość stopnia, cechy konstrukcyjne PN-EN 14975 Drabiny strychowe (schody) E Obciazenie statyczne, obciazenie cykliczne, skrecenie stopnia, wytrzymalosc poreczy, wytrzymalosc ogranicznikow, wytrzymalosc stopnia, cechy konstrukcyjne PN-EN 14975","categories":["other"],"row_index":345,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Loft ladders (stairs) E Static load, cyclic load, step torsion, handrail strength, strength of stops, step strength, design features PN-EN 14975"},{"_id":"6a5a55f19af9f73f3825106e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi przesuwne i składane, okucia do drzwi przesuwnych i składanych E","test_object_en":"Sliding and folding doors, hardware for sliding and folding doors E","methodology":"Obciążenia statyczne","methodology_en":"Static loads","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Obciążenia statyczne","reference":"PN-EN 1527","norm_bases":["PN-EN 1527"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi przesuwne i składane, okucia do drzwi przesuwnych i składanych E Obciążenia statyczne PN-EN 1527 Drzwi przesuwne i skladane, okucia do drzwi przesuwnych i skladanych E Obciazenia statyczne PN-EN 1527","categories":["other"],"row_index":346,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sliding and folding doors, hardware for sliding and folding doors E Static loads PN-EN 1527","search_zh":"推拉门与折叠门、推拉门与折叠门五金件 E PN-EN 1527","test_object_zh":"推拉门与折叠门、推拉门与折叠门五金件 E"},{"_id":"6a5a55f19af9f73f3825106f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi przesuwne i składane, okucia do drzwi przesuwnych i składanych E","test_object_en":"Sliding and folding doors, hardware for sliding and folding doors E","methodology":"Siła tarcia","methodology_en":"Friction force","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła tarcia","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi przesuwne i składane, okucia do drzwi przesuwnych i składanych E Siła tarcia Drzwi przesuwne i skladane, okucia do drzwi przesuwnych i skladanych E Sila tarcia","categories":["other"],"row_index":347,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sliding and folding doors, hardware for sliding and folding doors E Friction force","search_zh":"推拉门与折叠门、推拉门与折叠门五金件 E","test_object_zh":"推拉门与折叠门、推拉门与折叠门五金件 E"},{"_id":"6a5a55f19af9f73f38251070","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi przesuwne i składane, okucia do drzwi przesuwnych i składanych E","test_object_en":"Sliding and folding doors, hardware for sliding and folding doors E","methodology":"Trwałość","methodology_en":"Durability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi przesuwne i składane, okucia do drzwi przesuwnych i składanych E Trwałość Drzwi przesuwne i skladane, okucia do drzwi przesuwnych i skladanych E Trwalosc","categories":["other"],"row_index":348,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sliding and folding doors, hardware for sliding and folding doors E Durability","methodology_zh":"耐久性","search_zh":"推拉门与折叠门、推拉门与折叠门五金件 E 耐久性","test_object_zh":"推拉门与折叠门、推拉门与折叠门五金件 E"},{"_id":"6a5a55f19af9f73f38251071","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi przesuwne i składane, okucia do drzwi przesuwnych i składanych E","test_object_en":"Sliding and folding doors, hardware for sliding and folding doors E","methodology":"Właściwości i cechy do oceny bezpieczeństwa użytkowania +","methodology_en":"Properties and characteristics for the assessment of safety in use +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Właściwości i cechy do oceny bezpieczeństwa użytkowania +","reference":"EN 16005 PB LOW-018","norm_bases":["EN 16005 PB LOW-018"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi przesuwne i składane, okucia do drzwi przesuwnych i składanych E Właściwości i cechy do oceny bezpieczeństwa użytkowania + EN 16005 PB LOW-018 Drzwi przesuwne i skladane, okucia do drzwi przesuwnych i skladanych E Wlasciwosci i cechy do oceny bezpieczenstwa uzytkowania + EN 16005 PB LOW-018","categories":["other"],"row_index":349,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sliding and folding doors, hardware for sliding and folding doors E Properties and characteristics for the assessment of safety in use + EN 16005 PB LOW-018","search_zh":"推拉门与折叠门、推拉门与折叠门五金件 E EN 16005 PB LOW-018","test_object_zh":"推拉门与折叠门、推拉门与折叠门五金件 E"},{"_id":"6a5a55f19af9f73f38251072","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi przesuwne i składane, okucia do drzwi przesuwnych i składanych E","test_object_en":"Sliding and folding doors, hardware for sliding and folding doors E","methodology":"Wymiary, odległości między elementami +","methodology_en":"Dimensions, distances between elements +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary, odległości między elementami +","reference":"EN 16005","norm_bases":["EN 16005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi przesuwne i składane, okucia do drzwi przesuwnych i składanych E Wymiary, odległości między elementami + EN 16005 Drzwi przesuwne i skladane, okucia do drzwi przesuwnych i skladanych E Wymiary, odleglosci miedzy elementami + EN 16005","categories":["other"],"row_index":350,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sliding and folding doors, hardware for sliding and folding doors E Dimensions, distances between elements + EN 16005","search_zh":"推拉门与折叠门、推拉门与折叠门五金件 E EN 16005","test_object_zh":"推拉门与折叠门、推拉门与折叠门五金件 E"},{"_id":"6a5a55f19af9f73f38251073","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi przesuwne i składane, okucia do drzwi przesuwnych i składanych E","test_object_en":"Sliding and folding doors, hardware for sliding and folding doors E","methodology":"Prześwit +","methodology_en":"Clearance +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Prześwit +","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi przesuwne i składane, okucia do drzwi przesuwnych i składanych E Prześwit + Drzwi przesuwne i skladane, okucia do drzwi przesuwnych i skladanych E Przeswit +","categories":["other"],"row_index":351,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sliding and folding doors, hardware for sliding and folding doors E Clearance +","search_zh":"推拉门与折叠门、推拉门与折叠门五金件 E","test_object_zh":"推拉门与折叠门、推拉门与折叠门五金件 E"},{"_id":"6a5a55f19af9f73f38251074","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi przesuwne i składane, okucia do drzwi przesuwnych i składanych E","test_object_en":"Sliding and folding doors, hardware for sliding and folding doors E","methodology":"Siły otwarcia i zamknięcia +","methodology_en":"Opening and closing forces +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siły otwarcia i zamknięcia +","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi przesuwne i składane, okucia do drzwi przesuwnych i składanych E Siły otwarcia i zamknięcia + Drzwi przesuwne i skladane, okucia do drzwi przesuwnych i skladanych E Sily otwarcia i zamkniecia +","categories":["other"],"row_index":352,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sliding and folding doors, hardware for sliding and folding doors E Opening and closing forces +","search_zh":"推拉门与折叠门、推拉门与折叠门五金件 E","test_object_zh":"推拉门与折叠门、推拉门与折叠门五金件 E"},{"_id":"6a5a55f19af9f73f38251075","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi przesuwne i składane, okucia do drzwi przesuwnych i składanych E","test_object_en":"Sliding and folding doors, hardware for sliding and folding doors E","methodology":"Strefa aktywacji drzwi +","methodology_en":"Door activation zone +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Strefa aktywacji drzwi +","reference":"EN 16005 PB LOW-018","norm_bases":["EN 16005 PB LOW-018"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi przesuwne i składane, okucia do drzwi przesuwnych i składanych E Strefa aktywacji drzwi + EN 16005 PB LOW-018 Drzwi przesuwne i skladane, okucia do drzwi przesuwnych i skladanych E Strefa aktywacji drzwi + EN 16005 PB LOW-018","categories":["other"],"row_index":353,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sliding and folding doors, hardware for sliding and folding doors E Door activation zone + EN 16005 PB LOW-018","search_zh":"推拉门与折叠门、推拉门与折叠门五金件 E EN 16005 PB LOW-018","test_object_zh":"推拉门与折叠门、推拉门与折叠门五金件 E"},{"_id":"6a5a55f19af9f73f38251076","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi przesuwne i składane, okucia do drzwi przesuwnych i składanych E","test_object_en":"Sliding and folding doors, hardware for sliding and folding doors E","methodology":"Trwałość (bez badań w ekstremalnych temperaturach)","methodology_en":"Durability (excluding tests at extreme temperatures)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość (bez badań w ekstremalnych temperaturach)","reference":"EN 16005 PB LOW-018","norm_bases":["EN 16005 PB LOW-018"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi przesuwne i składane, okucia do drzwi przesuwnych i składanych E Trwałość (bez badań w ekstremalnych temperaturach) EN 16005 PB LOW-018 Drzwi przesuwne i skladane, okucia do drzwi przesuwnych i skladanych E Trwalosc (bez badan w ekstremalnych temperaturach) EN 16005 PB LOW-018","categories":["other"],"row_index":354,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sliding and folding doors, hardware for sliding and folding doors E Durability (excluding tests at extreme temperatures) EN 16005 PB LOW-018","search_zh":"推拉门与折叠门、推拉门与折叠门五金件 E EN 16005 PB LOW-018","test_object_zh":"推拉门与折叠门、推拉门与折叠门五金件 E"},{"_id":"6a5a55f19af9f73f38251077","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi przesuwne i składane, okucia do drzwi przesuwnych i składanych E","test_object_en":"Sliding and folding doors, hardware for sliding and folding doors E","methodology":"Siły udarowe +","methodology_en":"Impact forces +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siły udarowe +","reference":"EN 16005","norm_bases":["EN 16005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi przesuwne i składane, okucia do drzwi przesuwnych i składanych E Siły udarowe + EN 16005 Drzwi przesuwne i skladane, okucia do drzwi przesuwnych i skladanych E Sily udarowe + EN 16005","categories":["other"],"row_index":355,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sliding and folding doors, hardware for sliding and folding doors E Impact forces + EN 16005","search_zh":"推拉门与折叠门、推拉门与折叠门五金件 E EN 16005","test_object_zh":"推拉门与折叠门、推拉门与折叠门五金件 E"},{"_id":"6a5a55f19af9f73f38251078","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi przesuwne i składane, okucia do drzwi przesuwnych i składanych E","test_object_en":"Sliding and folding doors, hardware for sliding and folding doors E","methodology":"Czas otwarcia","methodology_en":"Opening time","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Czas otwarcia","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi przesuwne i składane, okucia do drzwi przesuwnych i składanych E Czas otwarcia Drzwi przesuwne i skladane, okucia do drzwi przesuwnych i skladanych E Czas otwarcia","categories":["other"],"row_index":356,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sliding and folding doors, hardware for sliding and folding doors E Opening time","search_zh":"推拉门与折叠门、推拉门与折叠门五金件 E","test_object_zh":"推拉门与折叠门、推拉门与折叠门五金件 E"},{"_id":"6a5a55f19af9f73f38251079","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi przesuwne i składane, okucia do drzwi przesuwnych i składanych E","test_object_en":"Sliding and folding doors, hardware for sliding and folding doors E","methodology":"Siła wyłamania +","methodology_en":"Break-out force +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła wyłamania +","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi przesuwne i składane, okucia do drzwi przesuwnych i składanych E Siła wyłamania + Drzwi przesuwne i skladane, okucia do drzwi przesuwnych i skladanych E Sila wylamania +","categories":["other"],"row_index":357,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sliding and folding doors, hardware for sliding and folding doors E Break-out force +","search_zh":"推拉门与折叠门、推拉门与折叠门五金件 E","test_object_zh":"推拉门与折叠门、推拉门与折叠门五金件 E"},{"_id":"6a5a55f19af9f73f3825107a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi przesuwne i składane, okucia do drzwi przesuwnych i składanych E","test_object_en":"Sliding and folding doors, hardware for sliding and folding doors E","methodology":"Siły otwarcia i czas zamknięcia w warunkach małej energii +","methodology_en":"Opening forces and closing time under low-energy conditions +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siły otwarcia i czas zamknięcia w warunkach małej energii +","reference":"EN 16005 PB LOW-018","norm_bases":["EN 16005 PB LOW-018"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi przesuwne i składane, okucia do drzwi przesuwnych i składanych E Siły otwarcia i czas zamknięcia w warunkach małej energii + EN 16005 PB LOW-018 Drzwi przesuwne i skladane, okucia do drzwi przesuwnych i skladanych E Sily otwarcia i czas zamkniecia w warunkach malej energii + EN 16005 PB LOW-018","categories":["other"],"row_index":358,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sliding and folding doors, hardware for sliding and folding doors E Opening forces and closing time under low-energy conditions + EN 16005 PB LOW-018","search_zh":"推拉门与折叠门、推拉门与折叠门五金件 E EN 16005 PB LOW-018","test_object_zh":"推拉门与折叠门、推拉门与折叠门五金件 E"},{"_id":"6a5a55f19af9f73f3825107b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy szkieletowej konstrukcji metalowej E","test_object_en":"Components of metal framed structures E","methodology":"Grubość powłoki","methodology_en":"Coating thickness","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Grubość powłoki","reference":"PN-EN ISO 2178 PN-EN ISO 2360","norm_bases":["PN-EN ISO 2178 PN-EN ISO 2360"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy szkieletowej konstrukcji metalowej E Grubość powłoki PN-EN ISO 2178 PN-EN ISO 2360 Elementy szkieletowej konstrukcji metalowej E Grubosc powloki PN-EN ISO 2178 PN-EN ISO 2360","categories":["materials"],"row_index":359,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Components of metal framed structures E Coating thickness PN-EN ISO 2178 PN-EN ISO 2360","methodology_zh":"涂层厚度","search_zh":"涂层厚度 PN-EN ISO 2178 PN-EN ISO 2360"},{"_id":"6a5a55f19af9f73f3825107c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy szkieletowej konstrukcji metalowej E","test_object_en":"Components of metal framed structures E","methodology":"Wymiary geometryczne liniowe","methodology_en":"Linear geometric dimensions","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary geometryczne liniowe","reference":"PN-EN 14195","norm_bases":["PN-EN 14195"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy szkieletowej konstrukcji metalowej E Wymiary geometryczne liniowe PN-EN 14195 Elementy szkieletowej konstrukcji metalowej E Wymiary geometryczne liniowe PN-EN 14195","categories":["materials"],"row_index":360,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Components of metal framed structures E Linear geometric dimensions PN-EN 14195","methodology_zh":"几何线性尺寸","search_zh":"几何线性尺寸 PN-EN 14195"},{"_id":"6a5a55f19af9f73f3825107d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy wyposażenia budownictwa E","test_object_en":"Building equipment components E","methodology":"Wykonanie +","methodology_en":"Workmanship +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wykonanie +","reference":"PN-EN 13018","norm_bases":["PN-EN 13018"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy wyposażenia budownictwa E Wykonanie + PN-EN 13018 Elementy wyposazenia budownictwa E Wykonanie + PN-EN 13018","categories":["other"],"row_index":361,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building equipment components E Workmanship + PN-EN 13018","methodology_zh":"制作工艺 +","search_zh":"建筑配套构件 E 制作工艺 + PN-EN 13018","test_object_zh":"建筑配套构件 E"},{"_id":"6a5a55f19af9f73f3825107e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy wyposażenia budownictwa E","test_object_en":"Building equipment components E","methodology":"Przyczepność okleiny do podłoża","methodology_en":"Adhesion of the veneer to the substrate","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przyczepność okleiny do podłoża","reference":"PN-EN 311","norm_bases":["PN-EN 311"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy wyposażenia budownictwa E Przyczepność okleiny do podłoża PN-EN 311 Elementy wyposazenia budownictwa E Przyczepnosc okleiny do podloza PN-EN 311","categories":["other"],"row_index":362,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building equipment components E Adhesion of the veneer to the substrate PN-EN 311","search_zh":"建筑配套构件 E PN-EN 311","test_object_zh":"建筑配套构件 E"},{"_id":"6a5a55f19af9f73f3825107f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy wyposażenia budownictwa E","test_object_en":"Building equipment components E","methodology":"Twardość Zakres: (20 - 70) HRC Metoda: Rockwella","methodology_en":"Hardness Range: (20 - 70) HRC Method: Rockwell","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Twardość Zakres: (20 - 70) HRC Metoda: Rockwella","reference":"PN-EN ISO 6508-1","norm_bases":["PN-EN ISO 6508-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy wyposażenia budownictwa E Twardość Zakres: (20 - 70) HRC Metoda: Rockwella PN-EN ISO 6508-1 Elementy wyposazenia budownictwa E Twardosc Zakres: (20 - 70) HRC Metoda: Rockwella PN-EN ISO 6508-1","categories":["other"],"row_index":363,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building equipment components E Hardness Range: (20 - 70) HRC Method: Rockwell PN-EN ISO 6508-1","search_zh":"建筑配套构件 E PN-EN ISO 6508-1","test_object_zh":"建筑配套构件 E"},{"_id":"6a5a55f19af9f73f38251080","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy wyposażeniowe i wykończeniowe z tworzyw sztucznych za wyjątkiem kształtowników do produkcji okien i drzwi E","test_object_en":"Plastic fitting and finishing components, except profiles for the manufacture of windows and doors E","methodology":"Odporność na zaplamienie","methodology_en":"Stain resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zaplamienie","reference":"PN-EN 438-2","norm_bases":["PN-EN 438-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy wyposażeniowe i wykończeniowe z tworzyw sztucznych za wyjątkiem kształtowników do produkcji okien i drzwi E Odporność na zaplamienie PN-EN 438-2 Elementy wyposazeniowe i wykonczeniowe z tworzyw sztucznych za wyjatkiem ksztaltownikow do produkcji okien i drzwi E Odpornosc na zaplamienie PN-EN 438-2","categories":["other"],"row_index":364,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic fitting and finishing components, except profiles for the manufacture of windows and doors E Stain resistance PN-EN 438-2","search_zh":"塑料配套与装饰构件，门窗生产用型材除外 E PN-EN 438-2","test_object_zh":"塑料配套与装饰构件，门窗生产用型材除外 E"},{"_id":"6a5a55f19af9f73f38251081","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy wyposażeniowe i wykończeniowe z tworzyw sztucznych za wyjątkiem kształtowników do produkcji okien i drzwi E","test_object_en":"Plastic fitting and finishing components, except profiles for the manufacture of windows and doors E","methodology":"Odporność na żar papierosa","methodology_en":"Resistance to cigarette ember","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na żar papierosa","reference":"PN-EN 438-2","norm_bases":["PN-EN 438-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy wyposażeniowe i wykończeniowe z tworzyw sztucznych za wyjątkiem kształtowników do produkcji okien i drzwi E Odporność na żar papierosa PN-EN 438-2 Elementy wyposazeniowe i wykonczeniowe z tworzyw sztucznych za wyjatkiem ksztaltownikow do produkcji okien i drzwi E Odpornosc na zar papierosa PN-EN 438-2","categories":["other"],"row_index":365,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic fitting and finishing components, except profiles for the manufacture of windows and doors E Resistance to cigarette ember PN-EN 438-2","search_zh":"塑料配套与装饰构件，门窗生产用型材除外 E PN-EN 438-2","test_object_zh":"塑料配套与装饰构件，门窗生产用型材除外 E"},{"_id":"6a5a55f19af9f73f38251082","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy wyposażeniowe i wykończeniowe z tworzyw sztucznych za wyjątkiem kształtowników do produkcji okien i drzwi E","test_object_en":"Plastic fitting and finishing components, except profiles for the manufacture of windows and doors E","methodology":"Odporność kształtowników głównych na uderzenie spadającego ciężarka","methodology_en":"Resistance of main profiles to impact of a falling weight","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność kształtowników głównych na uderzenie spadającego ciężarka","reference":"PN-EN 477","norm_bases":["PN-EN 477"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy wyposażeniowe i wykończeniowe z tworzyw sztucznych za wyjątkiem kształtowników do produkcji okien i drzwi E Odporność kształtowników głównych na uderzenie spadającego ciężarka PN-EN 477 Elementy wyposazeniowe i wykonczeniowe z tworzyw sztucznych za wyjatkiem ksztaltownikow do produkcji okien i drzwi E Odpornosc ksztaltownikow glownych na uderzenie spadajacego ciezarka PN-EN 477","categories":["other"],"row_index":366,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic fitting and finishing components, except profiles for the manufacture of windows and doors E Resistance of main profiles to impact of a falling weight PN-EN 477","search_zh":"塑料配套与装饰构件，门窗生产用型材除外 E PN-EN 477","test_object_zh":"塑料配套与装饰构件，门窗生产用型材除外 E"},{"_id":"6a5a55f19af9f73f38251083","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy wyposażeniowe i wykończeniowe z tworzyw sztucznych za wyjątkiem kształtowników do produkcji okien i drzwi E","test_object_en":"Plastic fitting and finishing components, except profiles for the manufacture of windows and doors E","methodology":"Skurcz termiczny","methodology_en":"Thermal shrinkage","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skurcz termiczny","reference":"PN-EN 479","norm_bases":["PN-EN 479"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy wyposażeniowe i wykończeniowe z tworzyw sztucznych za wyjątkiem kształtowników do produkcji okien i drzwi E Skurcz termiczny PN-EN 479 Elementy wyposazeniowe i wykonczeniowe z tworzyw sztucznych za wyjatkiem ksztaltownikow do produkcji okien i drzwi E Skurcz termiczny PN-EN 479","categories":["other"],"row_index":367,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic fitting and finishing components, except profiles for the manufacture of windows and doors E Thermal shrinkage PN-EN 479","search_zh":"塑料配套与装饰构件，门窗生产用型材除外 E PN-EN 479","test_object_zh":"塑料配套与装饰构件，门窗生产用型材除外 E"},{"_id":"6a5a55f19af9f73f38251084","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy wyposażeniowe i wykończeniowe z tworzyw sztucznych za wyjątkiem kształtowników do produkcji okien i drzwi E","test_object_en":"Plastic fitting and finishing components, except profiles for the manufacture of windows and doors E","methodology":"Wytrzymałość zgrzewanych naroży i połączeń w kształcie litery T w zakresie: (0 - 100) kN","methodology_en":"Strength of welded corners and T-shaped joints in the range: (0 - 100) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość zgrzewanych naroży i połączeń w kształcie litery T w zakresie: (0 - 100) kN","reference":"PN-EN 514","norm_bases":["PN-EN 514"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy wyposażeniowe i wykończeniowe z tworzyw sztucznych za wyjątkiem kształtowników do produkcji okien i drzwi E Wytrzymałość zgrzewanych naroży i połączeń w kształcie litery T w zakresie: (0 - 100) kN PN-EN 514 Elementy wyposazeniowe i wykonczeniowe z tworzyw sztucznych za wyjatkiem ksztaltownikow do produkcji okien i drzwi E Wytrzymalosc zgrzewanych narozy i polaczen w ksztalcie litery T w zakresie: (0 - 100) kN PN-EN 514","categories":["other"],"row_index":368,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic fitting and finishing components, except profiles for the manufacture of windows and doors E Strength of welded corners and T-shaped joints in the range: (0 - 100) kN PN-EN 514","search_zh":"塑料配套与装饰构件，门窗生产用型材除外 E PN-EN 514","test_object_zh":"塑料配套与装饰构件，门窗生产用型材除外 E"},{"_id":"6a5a55f19af9f73f38251085","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy wyposażeniowe i wykończeniowe z tworzyw sztucznych za wyjątkiem kształtowników do produkcji okien i drzwi E","test_object_en":"Plastic fitting and finishing components, except profiles for the manufacture of windows and doors E","methodology":"Wygląd po wygrzewaniu w temperaturze 150°C","methodology_en":"Appearance after heating at 150°C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wygląd po wygrzewaniu w temperaturze 150°C","reference":"PN-EN 478","norm_bases":["PN-EN 478"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy wyposażeniowe i wykończeniowe z tworzyw sztucznych za wyjątkiem kształtowników do produkcji okien i drzwi E Wygląd po wygrzewaniu w temperaturze 150°C PN-EN 478 Elementy wyposazeniowe i wykonczeniowe z tworzyw sztucznych za wyjatkiem ksztaltownikow do produkcji okien i drzwi E Wyglad po wygrzewaniu w temperaturze 150°C PN-EN 478","categories":["other"],"row_index":369,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic fitting and finishing components, except profiles for the manufacture of windows and doors E Appearance after heating at 150°C PN-EN 478","search_zh":"塑料配套与装饰构件，门窗生产用型材除外 E PN-EN 478","test_object_zh":"塑料配套与装饰构件，门窗生产用型材除外 E"},{"_id":"6a5a55f19af9f73f38251086","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kabiny prysznicowe E","test_object_en":"Shower enclosures E","methodology":"Stabilność","methodology_en":"Stability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stabilność","reference":"PN-EN 14428","norm_bases":["PN-EN 14428"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kabiny prysznicowe E Stabilność PN-EN 14428 Kabiny prysznicowe E Stabilnosc PN-EN 14428","categories":["other"],"row_index":370,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Shower enclosures E Stability PN-EN 14428","search_zh":"淋浴房 E 稳定性 PN-EN 14428","test_object_zh":"淋浴房 E","methodology_zh":"稳定性"},{"_id":"6a5a55f19af9f73f38251087","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kabiny prysznicowe E","test_object_en":"Shower enclosures E","methodology":"Szczelność","methodology_en":"Leak tightness","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kabiny prysznicowe E Szczelność Kabiny prysznicowe E Szczelnosc","categories":["other"],"row_index":371,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Shower enclosures E Leak tightness","methodology_zh":"密封性","search_zh":"淋浴房 E 密封性","test_object_zh":"淋浴房 E"},{"_id":"6a5a55f19af9f73f38251088","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kabiny prysznicowe E","test_object_en":"Shower enclosures E","methodology":"Odporność na chemikalia i środki plamiące","methodology_en":"Resistance to chemicals and staining agents","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na chemikalia i środki plamiące","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kabiny prysznicowe E Odporność na chemikalia i środki plamiące Kabiny prysznicowe E Odpornosc na chemikalia i srodki plamiace","categories":["other"],"row_index":372,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Shower enclosures E Resistance to chemicals and staining agents","search_zh":"淋浴房 E","test_object_zh":"淋浴房 E"},{"_id":"6a5a55f19af9f73f38251089","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klamki i gałki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E","test_object_en":"Door handles and knobs with roses, window and balcony door handles E","methodology":"Luz swobodny Wymiary geometryczne liniowe i kątowe","methodology_en":"Free play Linear and angular geometric dimensions","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Luz swobodny Wymiary geometryczne liniowe i kątowe","reference":"PN-EN 1906","norm_bases":["PN-EN 1906"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klamki i gałki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E Luz swobodny Wymiary geometryczne liniowe i kątowe PN-EN 1906 Klamki i galki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E Luz swobodny Wymiary geometryczne liniowe i katowe PN-EN 1906","categories":["other"],"row_index":373,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Door handles and knobs with roses, window and balcony door handles E Free play Linear and angular geometric dimensions PN-EN 1906","search_zh":"带面板的门把手与门球、窗与阳台门执手 E PN-EN 1906","test_object_zh":"带面板的门把手与门球、窗与阳台门执手 E"},{"_id":"6a5a55f19af9f73f3825108a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klamki i gałki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E","test_object_en":"Door handles and knobs with roses, window and balcony door handles E","methodology":"Moment obrotowy mechanizmu powrotnego Zakres: (0 - 350) Nm","methodology_en":"Torque of the return mechanism Range: (0 - 350) Nm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moment obrotowy mechanizmu powrotnego Zakres: (0 - 350) Nm","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klamki i gałki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E Moment obrotowy mechanizmu powrotnego Zakres: (0 - 350) Nm Klamki i galki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E Moment obrotowy mechanizmu powrotnego Zakres: (0 - 350) Nm","categories":["other"],"row_index":374,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Door handles and knobs with roses, window and balcony door handles E Torque of the return mechanism Range: (0 - 350) Nm","search_zh":"带面板的门把手与门球、窗与阳台门执手 E","test_object_zh":"带面板的门把手与门球、窗与阳台门执手 E"},{"_id":"6a5a55f19af9f73f3825108b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klamki i gałki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E","test_object_en":"Door handles and knobs with roses, window and balcony door handles E","methodology":"Odporność na atak z użyciem przecinaka","methodology_en":"Resistance to attack using a chisel","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na atak z użyciem przecinaka","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klamki i gałki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E Odporność na atak z użyciem przecinaka Klamki i galki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E Odpornosc na atak z uzyciem przecinaka","categories":["other"],"row_index":375,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Door handles and knobs with roses, window and balcony door handles E Resistance to attack using a chisel","search_zh":"带面板的门把手与门球、窗与阳台门执手 E","test_object_zh":"带面板的门把手与门球、窗与阳台门执手 E"},{"_id":"6a5a55f19af9f73f3825108c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klamki i gałki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E","test_object_en":"Door handles and knobs with roses, window and balcony door handles E","methodology":"Odporność na atak z użyciem wiercenia","methodology_en":"Resistance to attack using drilling","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na atak z użyciem wiercenia","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klamki i gałki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E Odporność na atak z użyciem wiercenia Klamki i galki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E Odpornosc na atak z uzyciem wiercenia","categories":["other"],"row_index":376,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Door handles and knobs with roses, window and balcony door handles E Resistance to attack using drilling","search_zh":"带面板的门把手与门球、窗与阳台门执手 E","test_object_zh":"带面板的门把手与门球、窗与阳台门执手 E"},{"_id":"6a5a55f19af9f73f3825108d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klamki i gałki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E","test_object_en":"Door handles and knobs with roses, window and balcony door handles E","methodology":"Swobodny ruch kątowy, niewspółosiowość","methodology_en":"Free angular movement, misalignment","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Swobodny ruch kątowy, niewspółosiowość","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klamki i gałki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E Swobodny ruch kątowy, niewspółosiowość Klamki i galki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E Swobodny ruch katowy, niewspolosiowosc","categories":["other"],"row_index":377,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Door handles and knobs with roses, window and balcony door handles E Free angular movement, misalignment","search_zh":"带面板的门把手与门球、窗与阳台门执手 E","test_object_zh":"带面板的门把手与门球、窗与阳台门执手 E"},{"_id":"6a5a55f19af9f73f3825108e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klamki i gałki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E","test_object_en":"Door handles and knobs with roses, window and balcony door handles E","methodology":"Trwałość","methodology_en":"Durability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klamki i gałki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E Trwałość Klamki i galki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E Trwalosc","categories":["other"],"row_index":378,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Door handles and knobs with roses, window and balcony door handles E Durability","methodology_zh":"耐久性","search_zh":"带面板的门把手与门球、窗与阳台门执手 E 耐久性","test_object_zh":"带面板的门把手与门球、窗与阳台门执手 E"},{"_id":"6a5a55f19af9f73f3825108f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klamki i gałki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E","test_object_en":"Door handles and knobs with roses, window and balcony door handles E","methodology":"Wytrzymałość elementów mocujących Zakres: (0 - 100) kN","methodology_en":"Strength of the fastening elements Range: (0 - 100) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elementów mocujących Zakres: (0 - 100) kN","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klamki i gałki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E Wytrzymałość elementów mocujących Zakres: (0 - 100) kN Klamki i galki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E Wytrzymalosc elementow mocujacych Zakres: (0 - 100) kN","categories":["other"],"row_index":379,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Door handles and knobs with roses, window and balcony door handles E Strength of the fastening elements Range: (0 - 100) kN","search_zh":"带面板的门把手与门球、窗与阳台门执手 E","test_object_zh":"带面板的门把手与门球、窗与阳台门执手 E"},{"_id":"6a5a55f19af9f73f38251090","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klamki i gałki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E","test_object_en":"Door handles and knobs with roses, window and balcony door handles E","methodology":"Wytrzymałość na działanie momentu obrotowego Zakres: (0 - 350) Nm","methodology_en":"Resistance to torque Range: (0 - 350) Nm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na działanie momentu obrotowego Zakres: (0 - 350) Nm","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klamki i gałki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E Wytrzymałość na działanie momentu obrotowego Zakres: (0 - 350) Nm Klamki i galki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E Wytrzymalosc na dzialanie momentu obrotowego Zakres: (0 - 350) Nm","categories":["other"],"row_index":380,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Door handles and knobs with roses, window and balcony door handles E Resistance to torque Range: (0 - 350) Nm","search_zh":"带面板的门把手与门球、窗与阳台门执手 E","test_object_zh":"带面板的门把手与门球、窗与阳台门执手 E"},{"_id":"6a5a55f19af9f73f38251091","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klamki i gałki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E","test_object_en":"Door handles and knobs with roses, window and balcony door handles E","methodology":"Wytrzymałość osiowa","methodology_en":"Axial strength","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość osiowa","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klamki i gałki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E Wytrzymałość osiowa Klamki i galki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E Wytrzymalosc osiowa","categories":["other"],"row_index":381,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Door handles and knobs with roses, window and balcony door handles E Axial strength","search_zh":"带面板的门把手与门球、窗与阳台门执手 E","test_object_zh":"带面板的门把手与门球、窗与阳台门执手 E"},{"_id":"6a5a55f19af9f73f38251092","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klamki i gałki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E","test_object_en":"Door handles and knobs with roses, window and balcony door handles E","methodology":"Wytrzymałość płytki ochraniającej bębenek","methodology_en":"Strength of the drum protecting plate","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość płytki ochraniającej bębenek","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klamki i gałki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E Wytrzymałość płytki ochraniającej bębenek Klamki i galki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E Wytrzymalosc plytki ochraniajacej bebenek","categories":["other"],"row_index":382,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Door handles and knobs with roses, window and balcony door handles E Strength of the drum protecting plate","search_zh":"带面板的门把手与门球、窗与阳台门执手 E","test_object_zh":"带面板的门把手与门球、窗与阳台门执手 E"},{"_id":"6a5a55f19af9f73f38251093","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klamki i gałki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E","test_object_en":"Door handles and knobs with roses, window and balcony door handles E","methodology":"Wytrzymałość tarczy","methodology_en":"Strength of the visor","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość tarczy","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klamki i gałki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E Wytrzymałość tarczy Klamki i galki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E Wytrzymalosc tarczy","categories":["other"],"row_index":383,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Door handles and knobs with roses, window and balcony door handles E Strength of the visor","search_zh":"带面板的门把手与门球、窗与阳台门执手 E","test_object_zh":"带面板的门把手与门球、窗与阳台门执手 E"},{"_id":"6a5a55f19af9f73f38251094","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klamki i gałki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E","test_object_en":"Door handles and knobs with roses, window and balcony door handles E","methodology":"Odporność korozyjna w obojętnej mgle solnej Metoda NSS","methodology_en":"Corrosion resistance in neutral salt spray NSS method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność korozyjna w obojętnej mgle solnej Metoda NSS","reference":"PN-EN ISO 9227","norm_bases":["PN-EN ISO 9227"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klamki i gałki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E Odporność korozyjna w obojętnej mgle solnej Metoda NSS PN-EN ISO 9227 Klamki i galki drzwiowe z tarczami, klameczki do okien i drzwi balkonowych E Odpornosc korozyjna w obojetnej mgle solnej Metoda NSS PN-EN ISO 9227","categories":["other"],"row_index":384,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Door handles and knobs with roses, window and balcony door handles E Corrosion resistance in neutral salt spray NSS method PN-EN ISO 9227","search_zh":"带面板的门把手与门球、窗与阳台门执手 E PN-EN ISO 9227","test_object_zh":"带面板的门把手与门球、窗与阳台门执手 E"},{"_id":"6a5a55f19af9f73f38251095","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klameczki E","test_object_en":"Handles E","methodology":"Moment operacyjny Zakres: (0,99 - 30) Nm","methodology_en":"Operating torque Range: (0,99 - 30) Nm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moment operacyjny Zakres: (0,99 - 30) Nm","reference":"PN-EN 13126-3","norm_bases":["PN-EN 13126-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klameczki E Moment operacyjny Zakres: (0,99 - 30) Nm PN-EN 13126-3 Klameczki E Moment operacyjny Zakres: (0,99 - 30) Nm PN-EN 13126-3","categories":["other"],"row_index":385,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Handles E Operating torque Range: (0,99 - 30) Nm PN-EN 13126-3","search_zh":"执手 E 操作力矩 范围：(0,99 - 30) Nm PN-EN 13126-3","test_object_zh":"执手 E","methodology_zh":"操作力矩 范围：(0,99 - 30) Nm"},{"_id":"6a5a55f19af9f73f38251096","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klameczki E","test_object_en":"Handles E","methodology":"Wytrzymałość połączenia trzpienia z klameczką Zakres: (0 - 100) kN","methodology_en":"Strength of the connection between the spindle and the handle Range: (0 - 100) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość połączenia trzpienia z klameczką Zakres: (0 - 100) kN","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klameczki E Wytrzymałość połączenia trzpienia z klameczką Zakres: (0 - 100) kN Klameczki E Wytrzymalosc polaczenia trzpienia z klameczka Zakres: (0 - 100) kN","categories":["other"],"row_index":386,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Handles E Strength of the connection between the spindle and the handle Range: (0 - 100) kN","search_zh":"执手 E","test_object_zh":"执手 E"},{"_id":"6a5a55f19af9f73f38251097","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klameczki E","test_object_en":"Handles E","methodology":"Wytrzymałość na skręcanie (moment obrotowy) Zakres: (0 - 500) Nm","methodology_en":"Torsional strength (torque) Range: (0 - 500) Nm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na skręcanie (moment obrotowy) Zakres: (0 - 500) Nm","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klameczki E Wytrzymałość na skręcanie (moment obrotowy) Zakres: (0 - 500) Nm Klameczki E Wytrzymalosc na skrecanie (moment obrotowy) Zakres: (0 - 500) Nm","categories":["other"],"row_index":387,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Handles E Torsional strength (torque) Range: (0 - 500) Nm","search_zh":"执手 E","test_object_zh":"执手 E"},{"_id":"6a5a55f19af9f73f38251098","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klameczki E","test_object_en":"Handles E","methodology":"Trwałość","methodology_en":"Durability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość","reference":"PN-EN 13126-3","norm_bases":["PN-EN 13126-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klameczki E Trwałość PN-EN 13126-3 Klameczki E Trwalosc PN-EN 13126-3","categories":["other"],"row_index":388,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Handles E Durability PN-EN 13126-3","methodology_zh":"耐久性","search_zh":"执手 E 耐久性 PN-EN 13126-3","test_object_zh":"执手 E"},{"_id":"6a5a55f19af9f73f38251099","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klameczki E","test_object_en":"Handles E","methodology":"Luz swobodny","methodology_en":"Free play","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Luz swobodny","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klameczki E Luz swobodny Klameczki E Luz swobodny","categories":["other"],"row_index":389,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Handles E Free play","search_zh":"执手 E 空转间隙","test_object_zh":"执手 E","methodology_zh":"空转间隙"},{"_id":"6a5a55f19af9f73f3825109a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klameczki E","test_object_en":"Handles E","methodology":"Wytrzymałość na rozciąganie niewspółosiowe Zakres: (0 - 100) kN","methodology_en":"Off-axis tensile strength Range: (0 - 100) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na rozciąganie niewspółosiowe Zakres: (0 - 100) kN","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klameczki E Wytrzymałość na rozciąganie niewspółosiowe Zakres: (0 - 100) kN Klameczki E Wytrzymalosc na rozciaganie niewspolosiowe Zakres: (0 - 100) kN","categories":["other"],"row_index":390,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Handles E Off-axis tensile strength Range: (0 - 100) kN","search_zh":"执手 E 非同轴拉伸强度 范围：(0 - 100) kN","test_object_zh":"执手 E","methodology_zh":"非同轴拉伸强度 范围：(0 - 100) kN"},{"_id":"6a5a55f19af9f73f3825109b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klameczki E","test_object_en":"Handles E","methodology":"Odporność na korozję","methodology_en":"Corrosion resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na korozję","reference":"PN-EN ISO 9227","norm_bases":["PN-EN ISO 9227"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klameczki E Odporność na korozję PN-EN ISO 9227 Klameczki E Odpornosc na korozje PN-EN ISO 9227","categories":["other"],"row_index":391,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Handles E Corrosion resistance PN-EN ISO 9227","methodology_zh":"耐腐蚀性","search_zh":"执手 E 耐腐蚀性 PN-EN ISO 9227","test_object_zh":"执手 E"},{"_id":"6a5a55f19af9f73f3825109c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klameczki z blokadą bezkluczową E","test_object_en":"Window handles with keyless lock E","methodology":"Moment operacyjny Zakres: (0,99 - 30) Nm","methodology_en":"Operating torque Range: (0,99 - 30) Nm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moment operacyjny Zakres: (0,99 - 30) Nm","reference":"PN-EN 13126-3","norm_bases":["PN-EN 13126-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klameczki z blokadą bezkluczową E Moment operacyjny Zakres: (0,99 - 30) Nm PN-EN 13126-3 Klameczki z blokada bezkluczowa E Moment operacyjny Zakres: (0,99 - 30) Nm PN-EN 13126-3","categories":["other"],"row_index":392,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Window handles with keyless lock E Operating torque Range: (0,99 - 30) Nm PN-EN 13126-3","search_zh":"带无钥匙锁定的执手 E 操作力矩 范围：(0,99 - 30) Nm PN-EN 13126-3","test_object_zh":"带无钥匙锁定的执手 E","methodology_zh":"操作力矩 范围：(0,99 - 30) Nm"},{"_id":"6a5a55f19af9f73f3825109d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klameczki z blokadą bezkluczową E","test_object_en":"Window handles with keyless lock E","methodology":"Trwałość klameczki wraz z blokadą","methodology_en":"Durability of the handle together with the locking device","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość klameczki wraz z blokadą","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klameczki z blokadą bezkluczową E Trwałość klameczki wraz z blokadą Klameczki z blokada bezkluczowa E Trwalosc klameczki wraz z blokada","categories":["other"],"row_index":393,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Window handles with keyless lock E Durability of the handle together with the locking device","search_zh":"带无钥匙锁定的执手 E","test_object_zh":"带无钥匙锁定的执手 E"},{"_id":"6a5a55f19af9f73f3825109e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klameczki z blokadą bezkluczową E","test_object_en":"Window handles with keyless lock E","methodology":"Luz swobodny","methodology_en":"Free play","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Luz swobodny","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klameczki z blokadą bezkluczową E Luz swobodny Klameczki z blokada bezkluczowa E Luz swobodny","categories":["other"],"row_index":394,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Window handles with keyless lock E Free play","search_zh":"带无钥匙锁定的执手 E 空转间隙","test_object_zh":"带无钥匙锁定的执手 E","methodology_zh":"空转间隙"},{"_id":"6a5a55f19af9f73f3825109f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klameczki z blokadą bezkluczową E","test_object_en":"Window handles with keyless lock E","methodology":"Wytrzymałość na skręcanie Zakres: (0 - 500) Nm","methodology_en":"Torsional strength Range: (0 - 500) Nm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na skręcanie Zakres: (0 - 500) Nm","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klameczki z blokadą bezkluczową E Wytrzymałość na skręcanie Zakres: (0 - 500) Nm Klameczki z blokada bezkluczowa E Wytrzymalosc na skrecanie Zakres: (0 - 500) Nm","categories":["other"],"row_index":395,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Window handles with keyless lock E Torsional strength Range: (0 - 500) Nm","search_zh":"带无钥匙锁定的执手 E","test_object_zh":"带无钥匙锁定的执手 E"},{"_id":"6a5a55f19af9f73f382510a0","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klameczki z blokadą bezkluczową E","test_object_en":"Window handles with keyless lock E","methodology":"Wytrzymałość na rozciąganie niewspółosiowe Zakres: (0 - 100) kN","methodology_en":"Off-axis tensile strength Range: (0 - 100) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na rozciąganie niewspółosiowe Zakres: (0 - 100) kN","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klameczki z blokadą bezkluczową E Wytrzymałość na rozciąganie niewspółosiowe Zakres: (0 - 100) kN Klameczki z blokada bezkluczowa E Wytrzymalosc na rozciaganie niewspolosiowe Zakres: (0 - 100) kN","categories":["other"],"row_index":396,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Window handles with keyless lock E Off-axis tensile strength Range: (0 - 100) kN","search_zh":"带无钥匙锁定的执手 E 非同轴拉伸强度 范围：(0 - 100) kN","test_object_zh":"带无钥匙锁定的执手 E","methodology_zh":"非同轴拉伸强度 范围：(0 - 100) kN"},{"_id":"6a5a55f19af9f73f382510a1","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klameczki z blokadą bezkluczową E","test_object_en":"Window handles with keyless lock E","methodology":"Wytrzymałość na ukręcenie („twisting off”) Zakres: (0 - 300) Nm","methodology_en":"Resistance to twisting off („twisting off”) Range: (0 - 300) Nm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ukręcenie („twisting off”) Zakres: (0 - 300) Nm","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klameczki z blokadą bezkluczową E Wytrzymałość na ukręcenie („twisting off”) Zakres: (0 - 300) Nm Klameczki z blokada bezkluczowa E Wytrzymalosc na ukrecenie („twisting off”) Zakres: (0 - 300) Nm","categories":["other"],"row_index":397,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Window handles with keyless lock E Resistance to twisting off („twisting off”) Range: (0 - 300) Nm","search_zh":"带无钥匙锁定的执手 E","test_object_zh":"带无钥匙锁定的执手 E"},{"_id":"6a5a55f19af9f73f382510a2","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klameczki z blokadą bezkluczową E","test_object_en":"Window handles with keyless lock E","methodology":"Wytrzymałość na wyłamanie („forcing off”) Zakres: (0 - 300) Nm","methodology_en":"Resistance to forcing off („forcing off”) Range: (0 - 300) Nm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na wyłamanie („forcing off”) Zakres: (0 - 300) Nm","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klameczki z blokadą bezkluczową E Wytrzymałość na wyłamanie („forcing off”) Zakres: (0 - 300) Nm Klameczki z blokada bezkluczowa E Wytrzymalosc na wylamanie („forcing off”) Zakres: (0 - 300) Nm","categories":["other"],"row_index":398,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Window handles with keyless lock E Resistance to forcing off („forcing off”) Range: (0 - 300) Nm","search_zh":"带无钥匙锁定的执手 E","test_object_zh":"带无钥匙锁定的执手 E"},{"_id":"6a5a55f19af9f73f382510a3","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klameczki z blokadą bezkluczową E","test_object_en":"Window handles with keyless lock E","methodology":"Wytrzymałość trzpienia na rozciąganie Zakres: (0 - 100) kN","methodology_en":"Tensile strength of the spindle Range: (0 - 100) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość trzpienia na rozciąganie Zakres: (0 - 100) kN","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klameczki z blokadą bezkluczową E Wytrzymałość trzpienia na rozciąganie Zakres: (0 - 100) kN Klameczki z blokada bezkluczowa E Wytrzymalosc trzpienia na rozciaganie Zakres: (0 - 100) kN","categories":["other"],"row_index":399,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Window handles with keyless lock E Tensile strength of the spindle Range: (0 - 100) kN","search_zh":"带无钥匙锁定的执手 E","test_object_zh":"带无钥匙锁定的执手 E"},{"_id":"6a5a55f19af9f73f382510a4","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klameczki z blokadą bezkluczową E","test_object_en":"Window handles with keyless lock E","methodology":"Odporność na korozję","methodology_en":"Corrosion resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na korozję","reference":"PN-EN ISO 9227","norm_bases":["PN-EN ISO 9227"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klameczki z blokadą bezkluczową E Odporność na korozję PN-EN ISO 9227 Klameczki z blokada bezkluczowa E Odpornosc na korozje PN-EN ISO 9227","categories":["other"],"row_index":400,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Window handles with keyless lock E Corrosion resistance PN-EN ISO 9227","methodology_zh":"耐腐蚀性","search_zh":"带无钥匙锁定的执手 E 耐腐蚀性 PN-EN ISO 9227","test_object_zh":"带无钥匙锁定的执手 E"},{"_id":"6a5a55f19af9f73f382510a5","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klameczki z blokadą kluczową E","test_object_en":"Window handles with key lock E","methodology":"Moment operacyjny Zakres: (0,99 - 30) Nm","methodology_en":"Operating torque Range: (0,99 - 30) Nm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moment operacyjny Zakres: (0,99 - 30) Nm","reference":"PN-EN 13126-3","norm_bases":["PN-EN 13126-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klameczki z blokadą kluczową E Moment operacyjny Zakres: (0,99 - 30) Nm PN-EN 13126-3 Klameczki z blokada kluczowa E Moment operacyjny Zakres: (0,99 - 30) Nm PN-EN 13126-3","categories":["other"],"row_index":401,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Window handles with key lock E Operating torque Range: (0,99 - 30) Nm PN-EN 13126-3","search_zh":"带钥匙锁定的执手 E 操作力矩 范围：(0,99 - 30) Nm PN-EN 13126-3","test_object_zh":"带钥匙锁定的执手 E","methodology_zh":"操作力矩 范围：(0,99 - 30) Nm"},{"_id":"6a5a55f19af9f73f382510a6","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klameczki z blokadą kluczową E","test_object_en":"Window handles with key lock E","methodology":"Trwałość","methodology_en":"Durability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klameczki z blokadą kluczową E Trwałość Klameczki z blokada kluczowa E Trwalosc","categories":["other"],"row_index":402,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Window handles with key lock E Durability","methodology_zh":"耐久性","search_zh":"带钥匙锁定的执手 E 耐久性","test_object_zh":"带钥匙锁定的执手 E"},{"_id":"6a5a55f19af9f73f382510a7","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klameczki z blokadą kluczową E","test_object_en":"Window handles with key lock E","methodology":"Luz swobodny","methodology_en":"Free play","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Luz swobodny","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klameczki z blokadą kluczową E Luz swobodny Klameczki z blokada kluczowa E Luz swobodny","categories":["other"],"row_index":403,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Window handles with key lock E Free play","search_zh":"带钥匙锁定的执手 E 空转间隙","test_object_zh":"带钥匙锁定的执手 E","methodology_zh":"空转间隙"},{"_id":"6a5a55f19af9f73f382510a8","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klameczki z blokadą kluczową E","test_object_en":"Window handles with key lock E","methodology":"Wytrzymałość na skręcanie (moment obrotowy) Zakres: (0 - 500) Nm","methodology_en":"Torsional strength (torque) Range: (0 - 500) Nm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na skręcanie (moment obrotowy) Zakres: (0 - 500) Nm","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klameczki z blokadą kluczową E Wytrzymałość na skręcanie (moment obrotowy) Zakres: (0 - 500) Nm Klameczki z blokada kluczowa E Wytrzymalosc na skrecanie (moment obrotowy) Zakres: (0 - 500) Nm","categories":["other"],"row_index":404,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Window handles with key lock E Torsional strength (torque) Range: (0 - 500) Nm","search_zh":"带钥匙锁定的执手 E","test_object_zh":"带钥匙锁定的执手 E"},{"_id":"6a5a55f19af9f73f382510a9","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klameczki z blokadą kluczową E","test_object_en":"Window handles with key lock E","methodology":"Wytrzymałość na rozciąganie niewspółosiowe Zakres: (0 - 100) kN","methodology_en":"Off-axis tensile strength Range: (0 - 100) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na rozciąganie niewspółosiowe Zakres: (0 - 100) kN","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klameczki z blokadą kluczową E Wytrzymałość na rozciąganie niewspółosiowe Zakres: (0 - 100) kN Klameczki z blokada kluczowa E Wytrzymalosc na rozciaganie niewspolosiowe Zakres: (0 - 100) kN","categories":["other"],"row_index":405,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Window handles with key lock E Off-axis tensile strength Range: (0 - 100) kN","search_zh":"带钥匙锁定的执手 E 非同轴拉伸强度 范围：(0 - 100) kN","test_object_zh":"带钥匙锁定的执手 E","methodology_zh":"非同轴拉伸强度 范围：(0 - 100) kN"},{"_id":"6a5a55f19af9f73f382510aa","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klameczki z blokadą kluczową E","test_object_en":"Window handles with key lock E","methodology":"Wytrzymałość na ukręcenie („twisting off”) Zakres: (0 - 300) Nm","methodology_en":"Resistance to twisting off („twisting off”) Range: (0 - 300) Nm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ukręcenie („twisting off”) Zakres: (0 - 300) Nm","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klameczki z blokadą kluczową E Wytrzymałość na ukręcenie („twisting off”) Zakres: (0 - 300) Nm Klameczki z blokada kluczowa E Wytrzymalosc na ukrecenie („twisting off”) Zakres: (0 - 300) Nm","categories":["other"],"row_index":406,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Window handles with key lock E Resistance to twisting off („twisting off”) Range: (0 - 300) Nm","search_zh":"带钥匙锁定的执手 E","test_object_zh":"带钥匙锁定的执手 E"},{"_id":"6a5a55f19af9f73f382510ab","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klameczki z blokadą kluczową E","test_object_en":"Window handles with key lock E","methodology":"Wytrzymałość na wyłamanie („forcing off”) Zakres: (0 - 300) Nm","methodology_en":"Resistance to forcing off („forcing off”) Range: (0 - 300) Nm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na wyłamanie („forcing off”) Zakres: (0 - 300) Nm","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klameczki z blokadą kluczową E Wytrzymałość na wyłamanie („forcing off”) Zakres: (0 - 300) Nm Klameczki z blokada kluczowa E Wytrzymalosc na wylamanie („forcing off”) Zakres: (0 - 300) Nm","categories":["other"],"row_index":407,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Window handles with key lock E Resistance to forcing off („forcing off”) Range: (0 - 300) Nm","search_zh":"带钥匙锁定的执手 E","test_object_zh":"带钥匙锁定的执手 E"},{"_id":"6a5a55f19af9f73f382510ac","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klameczki z blokadą kluczową E","test_object_en":"Window handles with key lock E","methodology":"Trwałość mechanizmu zamykającego","methodology_en":"Durability of the closing mechanism","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość mechanizmu zamykającego","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klameczki z blokadą kluczową E Trwałość mechanizmu zamykającego Klameczki z blokada kluczowa E Trwalosc mechanizmu zamykajacego","categories":["other"],"row_index":408,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Window handles with key lock E Durability of the closing mechanism","search_zh":"带钥匙锁定的执手 E","test_object_zh":"带钥匙锁定的执手 E"},{"_id":"6a5a55f19af9f73f382510ad","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klameczki z blokadą kluczową E","test_object_en":"Window handles with key lock E","methodology":"Odporność mechanizmu blokującego na skręcanie Zakres: (0 - 500) Nm","methodology_en":"Resistance of the locking mechanism to torsion Range: (0 - 500) Nm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność mechanizmu blokującego na skręcanie Zakres: (0 - 500) Nm","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klameczki z blokadą kluczową E Odporność mechanizmu blokującego na skręcanie Zakres: (0 - 500) Nm Klameczki z blokada kluczowa E Odpornosc mechanizmu blokujacego na skrecanie Zakres: (0 - 500) Nm","categories":["other"],"row_index":409,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Window handles with key lock E Resistance of the locking mechanism to torsion Range: (0 - 500) Nm","search_zh":"带钥匙锁定的执手 E","test_object_zh":"带钥匙锁定的执手 E"},{"_id":"6a5a55f19af9f73f382510ae","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klameczki z blokadą kluczową E","test_object_en":"Window handles with key lock E","methodology":"Wytrzymałość trzpienia na rozciąganie Zakres (0 - 100) kN","methodology_en":"Tensile strength of the spindle Range (0 - 100) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość trzpienia na rozciąganie Zakres (0 - 100) kN","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klameczki z blokadą kluczową E Wytrzymałość trzpienia na rozciąganie Zakres (0 - 100) kN Klameczki z blokada kluczowa E Wytrzymalosc trzpienia na rozciaganie Zakres (0 - 100) kN","categories":["other"],"row_index":410,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Window handles with key lock E Tensile strength of the spindle Range (0 - 100) kN","search_zh":"带钥匙锁定的执手 E","test_object_zh":"带钥匙锁定的执手 E"},{"_id":"6a5a55f19af9f73f382510af","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klameczki z blokadą kluczową E","test_object_en":"Window handles with key lock E","methodology":"Odporność na korozję","methodology_en":"Corrosion resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na korozję","reference":"PN-EN ISO 9227","norm_bases":["PN-EN ISO 9227"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klameczki z blokadą kluczową E Odporność na korozję PN-EN ISO 9227 Klameczki z blokada kluczowa E Odpornosc na korozje PN-EN ISO 9227","categories":["other"],"row_index":411,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Window handles with key lock E Corrosion resistance PN-EN ISO 9227","methodology_zh":"耐腐蚀性","search_zh":"带钥匙锁定的执手 E 耐腐蚀性 PN-EN ISO 9227","test_object_zh":"带钥匙锁定的执手 E"},{"_id":"6a5a55f19af9f73f382510b0","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kraty E","test_object_en":"Gratings E","methodology":"Odporność na włamanie - próba włamania ręcznego","methodology_en":"Burglar resistance - manual burglary attempt test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na włamanie - próba włamania ręcznego","reference":"PN-EN 1630","norm_bases":["PN-EN 1630"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kraty E Odporność na włamanie - próba włamania ręcznego PN-EN 1630 Kraty E Odpornosc na wlamanie - proba wlamania recznego PN-EN 1630","categories":["other"],"row_index":412,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gratings E Burglar resistance - manual burglary attempt test PN-EN 1630","methodology_zh":"抗侵入性 － 手工侵入试验","search_zh":"栅栏 E 抗侵入性 － 手工侵入试验 PN-EN 1630","test_object_zh":"栅栏 E"},{"_id":"6a5a55f19af9f73f382510b1","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kraty E","test_object_en":"Gratings E","methodology":"Odporność na włamanie przy obciążeniu dynamicznym","methodology_en":"Burglar resistance under dynamic load","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na włamanie przy obciążeniu dynamicznym","reference":"PN-EN 1629","norm_bases":["PN-EN 1629"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kraty E Odporność na włamanie przy obciążeniu dynamicznym PN-EN 1629 Kraty E Odpornosc na wlamanie przy obciazeniu dynamicznym PN-EN 1629","categories":["other"],"row_index":413,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gratings E Burglar resistance under dynamic load PN-EN 1629","methodology_zh":"动荷载下的抗侵入性","search_zh":"栅栏 E 动荷载下的抗侵入性 PN-EN 1629","test_object_zh":"栅栏 E"},{"_id":"6a5a55f19af9f73f382510b2","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kraty E","test_object_en":"Gratings E","methodology":"Odporność na włamanie przy obciążeniu statycznym","methodology_en":"Burglar resistance under static loading","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na włamanie przy obciążeniu statycznym","reference":"PN-EN 1628","norm_bases":["PN-EN 1628"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kraty E Odporność na włamanie przy obciążeniu statycznym PN-EN 1628 Kraty E Odpornosc na wlamanie przy obciazeniu statycznym PN-EN 1628","categories":["other"],"row_index":414,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gratings E Burglar resistance under static loading PN-EN 1628","methodology_zh":"静荷载下的抗侵入性","search_zh":"栅栏 E 静荷载下的抗侵入性 PN-EN 1628","test_object_zh":"栅栏 E"},{"_id":"6a5a55f19af9f73f382510b3","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kłódki E","test_object_en":"Padlocks E","methodology":"Zabezpieczenie przed włamaniem","methodology_en":"Burglary protection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zabezpieczenie przed włamaniem","reference":"PN-EN 12320","norm_bases":["PN-EN 12320"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kłódki E Zabezpieczenie przed włamaniem PN-EN 12320 Klodki E Zabezpieczenie przed wlamaniem PN-EN 12320","categories":["other"],"row_index":415,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Padlocks E Burglary protection PN-EN 12320"},{"_id":"6a5a55f19af9f73f382510b4","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Listwy metalowe, narożniki podtynkowe i obrzeża E","test_object_en":"Metal beads, plaster corner beads and edging E","methodology":"Grubość powłoki metodą magnetyczną","methodology_en":"Coating thickness by the magnetic method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Grubość powłoki metodą magnetyczną","reference":"PN-EN 13658-1 PN-EN 13658-2","norm_bases":["PN-EN 13658-1 PN-EN 13658-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Listwy metalowe, narożniki podtynkowe i obrzeża E Grubość powłoki metodą magnetyczną PN-EN 13658-1 PN-EN 13658-2 Listwy metalowe, narozniki podtynkowe i obrzeza E Grubosc powloki metoda magnetyczna PN-EN 13658-1 PN-EN 13658-2","categories":["materials"],"row_index":416,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Metal beads, plaster corner beads and edging E Coating thickness by the magnetic method PN-EN 13658-1 PN-EN 13658-2"},{"_id":"6a5a55f19af9f73f382510b5","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Listwy metalowe, narożniki podtynkowe i obrzeża E","test_object_en":"Metal beads, plaster corner beads and edging E","methodology":"Wymiary geometryczne liniowe","methodology_en":"Linear geometric dimensions","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary geometryczne liniowe","reference":"PN-EN 13658-1 PN-EN 13658-2","norm_bases":["PN-EN 13658-1 PN-EN 13658-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Listwy metalowe, narożniki podtynkowe i obrzeża E Wymiary geometryczne liniowe PN-EN 13658-1 PN-EN 13658-2 Listwy metalowe, narozniki podtynkowe i obrzeza E Wymiary geometryczne liniowe PN-EN 13658-1 PN-EN 13658-2","categories":["materials"],"row_index":417,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Metal beads, plaster corner beads and edging E Linear geometric dimensions PN-EN 13658-1 PN-EN 13658-2","methodology_zh":"几何线性尺寸","search_zh":"几何线性尺寸 PN-EN 13658-1 PN-EN 13658-2"},{"_id":"6a5a55f19af9f73f382510b6","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Napędy do bram i drzwi E","test_object_en":"Drives for gates and doors E","methodology":"Próg wykrywania +","methodology_en":"Detection threshold +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Próg wykrywania +","reference":"PN-EN 12978","norm_bases":["PN-EN 12978"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Napędy do bram i drzwi E Próg wykrywania + PN-EN 12978 Napedy do bram i drzwi E Prog wykrywania + PN-EN 12978","categories":["other"],"row_index":418,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Drives for gates and doors E Detection threshold + PN-EN 12978","search_zh":"大门与门的驱动装置 E PN-EN 12978","test_object_zh":"大门与门的驱动装置 E"},{"_id":"6a5a55f19af9f73f382510b7","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Napędy do bram i drzwi E","test_object_en":"Drives for gates and doors E","methodology":"Siła na krawędziach +","methodology_en":"Force at the edges +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła na krawędziach +","reference":"PN-EN 12445","norm_bases":["PN-EN 12445"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Napędy do bram i drzwi E Siła na krawędziach + PN-EN 12445 Napedy do bram i drzwi E Sila na krawedziach + PN-EN 12445","categories":["other"],"row_index":419,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Drives for gates and doors E Force at the edges + PN-EN 12445","search_zh":"大门与门的驱动装置 E PN-EN 12445","test_object_zh":"大门与门的驱动装置 E"},{"_id":"6a5a55f19af9f73f382510b8","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Napędy do bram i drzwi E","test_object_en":"Drives for gates and doors E","methodology":"Trwałość","methodology_en":"Durability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość","reference":"PN-EN 12605","norm_bases":["PN-EN 12605"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Napędy do bram i drzwi E Trwałość PN-EN 12605 Napedy do bram i drzwi E Trwalosc PN-EN 12605","categories":["other"],"row_index":420,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Drives for gates and doors E Durability PN-EN 12605","methodology_zh":"耐久性","search_zh":"大门与门的驱动装置 E 耐久性 PN-EN 12605","test_object_zh":"大门与门的驱动装置 E"},{"_id":"6a5a55f19af9f73f382510b9","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu","test_object_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated","methodology":"Odporność na obciążenia wiatrem +","methodology_en":"Resistance to wind loads +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenia wiatrem +","reference":"PN-EN 12211 „N”","norm_bases":["PN-EN 12211 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu Odporność na obciążenia wiatrem + PN-EN 12211 „N” Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane recznie lub za pomoca napedu Odpornosc na obciazenia wiatrem + PN-EN 12211 „N”","categories":["construction"],"row_index":421,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated Resistance to wind loads + PN-EN 12211 „N”","search_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置 PN-EN 12211 „N”","test_object_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置"},{"_id":"6a5a55f19af9f73f382510ba","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu","test_object_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated","methodology":"Odporność na uderzenie ciałem miękkim i ciężkim +","methodology_en":"Resistance to soft and heavy body impact +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie ciałem miękkim i ciężkim +","reference":"PN-EN 949 PN-EN 13049 „N”","norm_bases":["PN-EN 949 PN-EN 13049 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu Odporność na uderzenie ciałem miękkim i ciężkim + PN-EN 949 PN-EN 13049 „N” Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane recznie lub za pomoca napedu Odpornosc na uderzenie cialem miekkim i ciezkim + PN-EN 949 PN-EN 13049 „N”","categories":["construction"],"row_index":422,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated Resistance to soft and heavy body impact + PN-EN 949 PN-EN 13049 „N”","search_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置 软体与硬重物撞击抗力 + PN-EN 949 PN-EN 13049 „N”","test_object_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置","methodology_zh":"软体与硬重物撞击抗力 +"},{"_id":"6a5a55f19af9f73f382510bb","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu","test_object_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated","methodology":"Odporność na włamanie - próba włamania ręcznego","methodology_en":"Burglar resistance - manual burglary attempt test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na włamanie - próba włamania ręcznego","reference":"PN-EN 1630","norm_bases":["PN-EN 1630"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu Odporność na włamanie - próba włamania ręcznego PN-EN 1630 Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane recznie lub za pomoca napedu Odpornosc na wlamanie - proba wlamania recznego PN-EN 1630","categories":["construction"],"row_index":423,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated Burglar resistance - manual burglary attempt test PN-EN 1630","search_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置 抗侵入性 － 手工侵入试验 PN-EN 1630","test_object_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置","methodology_zh":"抗侵入性 － 手工侵入试验"},{"_id":"6a5a55f19af9f73f382510bc","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu","test_object_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated","methodology":"Odporność na włamanie przy obciążeniu dynamicznym","methodology_en":"Burglar resistance under dynamic load","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na włamanie przy obciążeniu dynamicznym","reference":"PN-EN 1629","norm_bases":["PN-EN 1629"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu Odporność na włamanie przy obciążeniu dynamicznym PN-EN 1629 Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane recznie lub za pomoca napedu Odpornosc na wlamanie przy obciazeniu dynamicznym PN-EN 1629","categories":["construction"],"row_index":424,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated Burglar resistance under dynamic load PN-EN 1629","search_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置 动荷载下的抗侵入性 PN-EN 1629","test_object_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置","methodology_zh":"动荷载下的抗侵入性"},{"_id":"6a5a55f19af9f73f382510bd","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu","test_object_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated","methodology":"Odporność na włamanie przy obciążeniu statycznym","methodology_en":"Burglar resistance under static loading","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na włamanie przy obciążeniu statycznym","reference":"PN-EN 1628","norm_bases":["PN-EN 1628"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu Odporność na włamanie przy obciążeniu statycznym PN-EN 1628 Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane recznie lub za pomoca napedu Odpornosc na wlamanie przy obciazeniu statycznym PN-EN 1628","categories":["construction"],"row_index":425,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated Burglar resistance under static loading PN-EN 1628","search_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置 静荷载下的抗侵入性 PN-EN 1628","test_object_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置","methodology_zh":"静荷载下的抗侵入性"},{"_id":"6a5a55f19af9f73f382510be","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu","test_object_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated","methodology":"Odporności na obciążenia w płaszczyźnie skrzydła","methodology_en":"Resistance to loads in the plane of the leaf","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporności na obciążenia w płaszczyźnie skrzydła","reference":"PN-EN 14608","norm_bases":["PN-EN 14608"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu Odporności na obciążenia w płaszczyźnie skrzydła PN-EN 14608 Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane recznie lub za pomoca napedu Odpornosci na obciazenia w plaszczyznie skrzydla PN-EN 14608","categories":["construction"],"row_index":426,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated Resistance to loads in the plane of the leaf PN-EN 14608","search_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置 PN-EN 14608","test_object_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置"},{"_id":"6a5a55f19af9f73f382510bf","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu","test_object_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated","methodology":"Wytrzymałość na skręcanie statyczne","methodology_en":"Static torsional strength","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na skręcanie statyczne","reference":"PN-EN 14609 „N”","norm_bases":["PN-EN 14609 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu Wytrzymałość na skręcanie statyczne PN-EN 14609 „N” Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane recznie lub za pomoca napedu Wytrzymalosc na skrecanie statyczne PN-EN 14609 „N”","categories":["construction"],"row_index":427,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated Static torsional strength PN-EN 14609 „N”","search_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置 静态抗扭强度 PN-EN 14609 „N”","test_object_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置","methodology_zh":"静态抗扭强度"},{"_id":"6a5a55f19af9f73f382510c0","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu","test_object_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated","methodology":"Nośność urządzeń zabezpieczających","methodology_en":"Load-bearing capacity of safety devices","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność urządzeń zabezpieczających","reference":"PN-EN 14351-1 PN-EN 14609 „N”","norm_bases":["PN-EN 14351-1 PN-EN 14609 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu Nośność urządzeń zabezpieczających PN-EN 14351-1 PN-EN 14609 „N” Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane recznie lub za pomoca napedu Nosnosc urzadzen zabezpieczajacych PN-EN 14351-1 PN-EN 14609 „N”","categories":["construction"],"row_index":428,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated Load-bearing capacity of safety devices PN-EN 14351-1 PN-EN 14609 „N”","search_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置 安全装置的承载力 PN-EN 14351-1 PN-EN 14609 „N”","test_object_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置","methodology_zh":"安全装置的承载力"},{"_id":"6a5a55f19af9f73f382510c1","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu","test_object_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated","methodology":"Siła, moment obrotowy Zakres: (0 - 350) Nm","methodology_en":"Force, torque Range: (0 - 350) Nm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła, moment obrotowy Zakres: (0 - 350) Nm","reference":"PN-EN 12046-1","norm_bases":["PN-EN 12046-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu Siła, moment obrotowy Zakres: (0 - 350) Nm PN-EN 12046-1 Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane recznie lub za pomoca napedu Sila, moment obrotowy Zakres: (0 - 350) Nm PN-EN 12046-1","categories":["construction"],"row_index":429,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated Force, torque Range: (0 - 350) Nm PN-EN 12046-1","search_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置 PN-EN 12046-1","test_object_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置"},{"_id":"6a5a55f19af9f73f382510c2","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu","test_object_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated","methodology":"Siły operacyjne Zakres: (0 - 5000) N","methodology_en":"Operating forces Range: (0 - 5000) N","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siły operacyjne Zakres: (0 - 5000) N","reference":"PN-EN 12046-1","norm_bases":["PN-EN 12046-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu Siły operacyjne Zakres: (0 - 5000) N PN-EN 12046-1 Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane recznie lub za pomoca napedu Sily operacyjne Zakres: (0 - 5000) N PN-EN 12046-1","categories":["construction"],"row_index":430,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated Operating forces Range: (0 - 5000) N PN-EN 12046-1","search_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置 PN-EN 12046-1","test_object_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置"},{"_id":"6a5a55f19af9f73f382510c3","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu","test_object_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated","methodology":"Wodoszczelność +","methodology_en":"Watertightness +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność +","reference":"PN-EN 1027 „N”","norm_bases":["PN-EN 1027 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane ręcznie lub za pomocą napędu Wodoszczelność + PN-EN 1027 „N” Okna E w tym: - drzwi balkonowe, - okna dachowe, - zestawy okienno-drzwiowe, - konstrukcje podobne, - uruchamiane recznie lub za pomoca napedu Wodoszczelnosc + PN-EN 1027 „N”","categories":["construction"],"row_index":431,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows E including: - balcony doors, - roof windows, - window-door sets, - similar constructions, - manually or power operated Watertightness + PN-EN 1027 „N”","search_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置 水密性 + PN-EN 1027 „N”","test_object_zh":"窗 E，其中包括： — 阳台门， — 屋面窗， — 窗门组件， — 类似结构， — 手动或带驱动装置","methodology_zh":"水密性 +"},{"_id":"6a5a55f19af9f73f382510c4","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Metalowe narożniki i profile specjalne do stosowania z płytami gipsowo-kartonowymi E","test_object_en":"Metal beads and special profiles for use with gypsum plasterboards E","methodology":"Wymiary geometryczne liniowe","methodology_en":"Linear geometric dimensions","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary geometryczne liniowe","reference":"PN-EN 14353","norm_bases":["PN-EN 14353"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Metalowe narożniki i profile specjalne do stosowania z płytami gipsowo-kartonowymi E Wymiary geometryczne liniowe PN-EN 14353 Metalowe narozniki i profile specjalne do stosowania z plytami gipsowo-kartonowymi E Wymiary geometryczne liniowe PN-EN 14353","categories":["materials"],"row_index":432,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Metal beads and special profiles for use with gypsum plasterboards E Linear geometric dimensions PN-EN 14353","methodology_zh":"几何线性尺寸","search_zh":"几何线性尺寸 PN-EN 14353"},{"_id":"6a5a55f19af9f73f382510c5","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Nity do średnicy 6.4 mm E","test_object_en":"Rivets up to 6.4 mm diameter E","methodology":"Obciążenie zrywające rdzeń","methodology_en":"Core breaking load","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Obciążenie zrywające rdzeń","reference":"PN-EN ISO 14589","norm_bases":["PN-EN ISO 14589"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Nity do średnicy 6.4 mm E Obciążenie zrywające rdzeń PN-EN ISO 14589 Nity do srednicy 6.4 mm E Obciazenie zrywajace rdzen PN-EN ISO 14589","categories":["other"],"row_index":433,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rivets up to 6.4 mm diameter E Core breaking load PN-EN ISO 14589","search_zh":"直径至 6,4 mm 的铆钉 E PN-EN ISO 14589","test_object_zh":"直径至 6,4 mm 的铆钉 E"},{"_id":"6a5a55f19af9f73f382510c6","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Nity do średnicy 6.4 mm E","test_object_en":"Rivets up to 6.4 mm diameter E","methodology":"Opór wypychania rdzenia","methodology_en":"Core push-out resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Opór wypychania rdzenia","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Nity do średnicy 6.4 mm E Opór wypychania rdzenia Nity do srednicy 6.4 mm E Opor wypychania rdzenia","categories":["other"],"row_index":434,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rivets up to 6.4 mm diameter E Core push-out resistance","search_zh":"直径至 6,4 mm 的铆钉 E","test_object_zh":"直径至 6,4 mm 的铆钉 E"},{"_id":"6a5a55f19af9f73f382510c7","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Nity do średnicy 6.4 mm E","test_object_en":"Rivets up to 6.4 mm diameter E","methodology":"Próba ścinania i rozciągania","methodology_en":"Shear and tensile test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Próba ścinania i rozciągania","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Nity do średnicy 6.4 mm E Próba ścinania i rozciągania Nity do srednicy 6.4 mm E Proba scinania i rozciagania","categories":["other"],"row_index":435,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rivets up to 6.4 mm diameter E Shear and tensile test","search_zh":"直径至 6,4 mm 的铆钉 E","test_object_zh":"直径至 6,4 mm 的铆钉 E"},{"_id":"6a5a55f19af9f73f382510c8","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Nity do średnicy 6.4 mm E","test_object_en":"Rivets up to 6.4 mm diameter E","methodology":"Zdolność utrzymania łba rdzenia","methodology_en":"Ability to retain the core head","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność utrzymania łba rdzenia","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Nity do średnicy 6.4 mm E Zdolność utrzymania łba rdzenia Nity do srednicy 6.4 mm E Zdolnosc utrzymania lba rdzenia","categories":["other"],"row_index":436,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rivets up to 6.4 mm diameter E Ability to retain the core head","search_zh":"直径至 6,4 mm 的铆钉 E","test_object_zh":"直径至 6,4 mm 的铆钉 E"},{"_id":"6a5a55f19af9f73f382510c9","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okucia budowlane i ich elementy E","test_object_en":"Building hardware and its components E","methodology":"Wykonanie +","methodology_en":"Workmanship +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wykonanie +","reference":"PN-EN 13018","norm_bases":["PN-EN 13018"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okucia budowlane i ich elementy E Wykonanie + PN-EN 13018 Okucia budowlane i ich elementy E Wykonanie + PN-EN 13018","categories":["construction"],"row_index":437,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building hardware and its components E Workmanship + PN-EN 13018","methodology_zh":"制作工艺 +","search_zh":"制作工艺 + PN-EN 13018"},{"_id":"6a5a55f19af9f73f382510ca","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okucia do okien i drzwi balkonowych E","test_object_en":"Hardware for windows and balcony doors E","methodology":"Trwałość","methodology_en":"Durability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość","reference":"PN-EN 13126-15 PN-EN 13126-16 PN-EN 13126-17 PN-EN 13126-7","norm_bases":["PN-EN 13126-15 PN-EN 13126-16 PN-EN 13126-17 PN-EN 13126-7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okucia do okien i drzwi balkonowych E Trwałość PN-EN 13126-15 PN-EN 13126-16 PN-EN 13126-17 PN-EN 13126-7 Okucia do okien i drzwi balkonowych E Trwalosc PN-EN 13126-15 PN-EN 13126-16 PN-EN 13126-17 PN-EN 13126-7","categories":["other"],"row_index":438,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Hardware for windows and balcony doors E Durability PN-EN 13126-15 PN-EN 13126-16 PN-EN 13126-17 PN-EN 13126-7","methodology_zh":"耐久性","search_zh":"窗与阳台门五金件 E 耐久性 PN-EN 13126-15 PN-EN 13126-16 PN-EN 13126-17 PN-EN 13126-7","test_object_zh":"窗与阳台门五金件 E"},{"_id":"6a5a55f19af9f73f382510cb","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okucia do okien i drzwi balkonowych E","test_object_en":"Hardware for windows and balcony doors E","methodology":"Wytrzymałość","methodology_en":"Strength","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość","reference":"PN-EN 13126-17 PN-EN 13126-7 PN-EN 13126-15 PN-EN 13126-16","norm_bases":["PN-EN 13126-17 PN-EN 13126-7 PN-EN 13126-15 PN-EN 13126-16"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okucia do okien i drzwi balkonowych E Wytrzymałość PN-EN 13126-17 PN-EN 13126-7 PN-EN 13126-15 PN-EN 13126-16 Okucia do okien i drzwi balkonowych E Wytrzymalosc PN-EN 13126-17 PN-EN 13126-7 PN-EN 13126-15 PN-EN 13126-16","categories":["other"],"row_index":439,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Hardware for windows and balcony doors E Strength PN-EN 13126-17 PN-EN 13126-7 PN-EN 13126-15 PN-EN 13126-16","search_zh":"窗与阳台门五金件 E 强度 PN-EN 13126-17 PN-EN 13126-7 PN-EN 13126-15 PN-EN 13126-16","test_object_zh":"窗与阳台门五金件 E","methodology_zh":"强度"},{"_id":"6a5a55f19af9f73f382510cc","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okucia do okien i drzwi balkonowych E","test_object_en":"Hardware for windows and balcony doors E","methodology":"Zabezpieczenie i działanie okuć do uchylono-przesuwnych okien i drzwi balkonowych","methodology_en":"Safety and operation of hardware for tilt-and-slide windows and balcony doors","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zabezpieczenie i działanie okuć do uchylono-przesuwnych okien i drzwi balkonowych","reference":"PN-EN 13126-17","norm_bases":["PN-EN 13126-17"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okucia do okien i drzwi balkonowych E Zabezpieczenie i działanie okuć do uchylono-przesuwnych okien i drzwi balkonowych PN-EN 13126-17 Okucia do okien i drzwi balkonowych E Zabezpieczenie i dzialanie okuc do uchylono-przesuwnych okien i drzwi balkonowych PN-EN 13126-17","categories":["other"],"row_index":440,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Hardware for windows and balcony doors E Safety and operation of hardware for tilt-and-slide windows and balcony doors PN-EN 13126-17","search_zh":"窗与阳台门五金件 E PN-EN 13126-17","test_object_zh":"窗与阳台门五金件 E"},{"_id":"6a5a55f19af9f73f382510cd","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okucia do okien i drzwi balkonowych E","test_object_en":"Hardware for windows and balcony doors E","methodology":"Zabezpieczenie i działanie okuć do unoszono-przesuwnych okien i drzwi balkonowych","methodology_en":"Safety and operation of hardware for lift-and-slide windows and balcony doors","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zabezpieczenie i działanie okuć do unoszono-przesuwnych okien i drzwi balkonowych","reference":"PN-EN 13126-16","norm_bases":["PN-EN 13126-16"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okucia do okien i drzwi balkonowych E Zabezpieczenie i działanie okuć do unoszono-przesuwnych okien i drzwi balkonowych PN-EN 13126-16 Okucia do okien i drzwi balkonowych E Zabezpieczenie i dzialanie okuc do unoszono-przesuwnych okien i drzwi balkonowych PN-EN 13126-16","categories":["other"],"row_index":441,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Hardware for windows and balcony doors E Safety and operation of hardware for lift-and-slide windows and balcony doors PN-EN 13126-16","search_zh":"窗与阳台门五金件 E PN-EN 13126-16","test_object_zh":"窗与阳台门五金件 E"},{"_id":"6a5a55f19af9f73f382510ce","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okucia do okien i drzwi balkonowych E","test_object_en":"Hardware for windows and balcony doors E","methodology":"Zabezpieczenie i działanie rolek do przesuwnych poziomo i składanych okien i drzwi balkonowych","methodology_en":"Safety and operation of rollers for horizontally sliding and folding windows and balcony doors","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zabezpieczenie i działanie rolek do przesuwnych poziomo i składanych okien i drzwi balkonowych","reference":"PN-EN 13126-15","norm_bases":["PN-EN 13126-15"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okucia do okien i drzwi balkonowych E Zabezpieczenie i działanie rolek do przesuwnych poziomo i składanych okien i drzwi balkonowych PN-EN 13126-15 Okucia do okien i drzwi balkonowych E Zabezpieczenie i dzialanie rolek do przesuwnych poziomo i skladanych okien i drzwi balkonowych PN-EN 13126-15","categories":["other"],"row_index":442,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Hardware for windows and balcony doors E Safety and operation of rollers for horizontally sliding and folding windows and balcony doors PN-EN 13126-15","search_zh":"窗与阳台门五金件 E PN-EN 13126-15","test_object_zh":"窗与阳台门五金件 E"},{"_id":"6a5a55f19af9f73f382510cf","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okucia do okien i drzwi balkonowych E","test_object_en":"Hardware for windows and balcony doors E","methodology":"Zabezpieczenie i funkcjonalność zatrzasków zapadkowych","methodology_en":"Safety and functionality of latch bolts","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zabezpieczenie i funkcjonalność zatrzasków zapadkowych","reference":"PN-EN 13126-7","norm_bases":["PN-EN 13126-7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okucia do okien i drzwi balkonowych E Zabezpieczenie i funkcjonalność zatrzasków zapadkowych PN-EN 13126-7 Okucia do okien i drzwi balkonowych E Zabezpieczenie i funkcjonalnosc zatrzaskow zapadkowych PN-EN 13126-7","categories":["other"],"row_index":443,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Hardware for windows and balcony doors E Safety and functionality of latch bolts PN-EN 13126-7","search_zh":"窗与阳台门五金件 E PN-EN 13126-7","test_object_zh":"窗与阳台门五金件 E"},{"_id":"6a5a55f19af9f73f382510d0","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okucia uchylno-rozwierane, okucia rozwierano-uchylne, okucia uchylne, okucia rozwierane E","test_object_en":"Tilt-and-turn fittings, turn-and-tilt fittings, tilt fittings, turn fittings E","methodology":"Trwałość","methodology_en":"Durability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość","reference":"PN-EN 13126-8","norm_bases":["PN-EN 13126-8"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okucia uchylno-rozwierane, okucia rozwierano-uchylne, okucia uchylne, okucia rozwierane E Trwałość PN-EN 13126-8 Okucia uchylno-rozwierane, okucia rozwierano-uchylne, okucia uchylne, okucia rozwierane E Trwalosc PN-EN 13126-8","categories":["other"],"row_index":444,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Tilt-and-turn fittings, turn-and-tilt fittings, tilt fittings, turn fittings E Durability PN-EN 13126-8","methodology_zh":"耐久性","search_zh":"耐久性 PN-EN 13126-8"},{"_id":"6a5a55f19af9f73f382510d1","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okucia uchylno-rozwierane, okucia rozwierano-uchylne, okucia uchylne, okucia rozwierane E","test_object_en":"Tilt-and-turn fittings, turn-and-tilt fittings, tilt fittings, turn fittings E","methodology":"Wytrzymałość rozwórki i zawiasy narożnej Zakres: (0 - 100) kN","methodology_en":"Strength of the stay bar and the corner hinge Range: (0 - 100) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość rozwórki i zawiasy narożnej Zakres: (0 - 100) kN","reference":"PN-EN 13126-8","norm_bases":["PN-EN 13126-8"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okucia uchylno-rozwierane, okucia rozwierano-uchylne, okucia uchylne, okucia rozwierane E Wytrzymałość rozwórki i zawiasy narożnej Zakres: (0 - 100) kN PN-EN 13126-8 Okucia uchylno-rozwierane, okucia rozwierano-uchylne, okucia uchylne, okucia rozwierane E Wytrzymalosc rozworki i zawiasy naroznej Zakres: (0 - 100) kN PN-EN 13126-8","categories":["other"],"row_index":445,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Tilt-and-turn fittings, turn-and-tilt fittings, tilt fittings, turn fittings E Strength of the stay bar and the corner hinge Range: (0 - 100) kN PN-EN 13126-8"},{"_id":"6a5a55f19af9f73f382510d2","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Panele zgrzewane z drutu stalowego na ogrodzenia E","test_object_en":"Welded steel wire panels for fencing E","methodology":"Próba rozciągania","methodology_en":"Tensile test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Próba rozciągania","reference":"PN-EN 10218-1","norm_bases":["PN-EN 10218-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Panele zgrzewane z drutu stalowego na ogrodzenia E Próba rozciągania PN-EN 10218-1 Panele zgrzewane z drutu stalowego na ogrodzenia E Proba rozciagania PN-EN 10218-1","categories":["materials"],"row_index":446,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Welded steel wire panels for fencing E Tensile test PN-EN 10218-1","methodology_zh":"拉伸试验","search_zh":"围栏用钢丝焊接网片 E 拉伸试验 PN-EN 10218-1","test_object_zh":"围栏用钢丝焊接网片 E"},{"_id":"6a5a55f19af9f73f382510d3","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Panele zgrzewane z drutu stalowego na ogrodzenia E","test_object_en":"Welded steel wire panels for fencing E","methodology":"Wymiary geometryczne liniowe","methodology_en":"Linear geometric dimensions","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary geometryczne liniowe","reference":"PN-EN 10218-2","norm_bases":["PN-EN 10218-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Panele zgrzewane z drutu stalowego na ogrodzenia E Wymiary geometryczne liniowe PN-EN 10218-2 Panele zgrzewane z drutu stalowego na ogrodzenia E Wymiary geometryczne liniowe PN-EN 10218-2","categories":["materials"],"row_index":447,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Welded steel wire panels for fencing E Linear geometric dimensions PN-EN 10218-2","methodology_zh":"几何线性尺寸","search_zh":"围栏用钢丝焊接网片 E 几何线性尺寸 PN-EN 10218-2","test_object_zh":"围栏用钢丝焊接网片 E"},{"_id":"6a5a55f19af9f73f382510d4","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Panele zgrzewane z drutu stalowego na ogrodzenia E","test_object_en":"Welded steel wire panels for fencing E","methodology":"Wytrzymałość zgrzeiny na ścinanie","methodology_en":"Shear strength of the weld","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość zgrzeiny na ścinanie","reference":"PN-EN 10223-7","norm_bases":["PN-EN 10223-7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Panele zgrzewane z drutu stalowego na ogrodzenia E Wytrzymałość zgrzeiny na ścinanie PN-EN 10223-7 Panele zgrzewane z drutu stalowego na ogrodzenia E Wytrzymalosc zgrzeiny na scinanie PN-EN 10223-7","categories":["materials"],"row_index":448,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Welded steel wire panels for fencing E Shear strength of the weld PN-EN 10223-7","search_zh":"围栏用钢丝焊接网片 E PN-EN 10223-7","test_object_zh":"围栏用钢丝焊接网片 E"},{"_id":"6a5a55f19af9f73f382510d5","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Ościeżnice E","test_object_en":"Door frames E","methodology":"Odporność na uderzenie ciałem miękkim i ciężkim","methodology_en":"Resistance to soft and heavy body impact","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie ciałem miękkim i ciężkim","reference":"PN-EN 949","norm_bases":["PN-EN 949"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ościeżnice E Odporność na uderzenie ciałem miękkim i ciężkim PN-EN 949 Oscieznice E Odpornosc na uderzenie cialem miekkim i ciezkim PN-EN 949","categories":["other"],"row_index":449,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Door frames E Resistance to soft and heavy body impact PN-EN 949","methodology_zh":"软体与硬重物撞击抗力","search_zh":"软体与硬重物撞击抗力 PN-EN 949"},{"_id":"6a5a55f19af9f73f382510d6","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Pasma świetlne E","test_object_en":"Continuous rooflights E","methodology":"Przepuszczalność powietrza","methodology_en":"Air permeability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność powietrza","reference":"PN-EN 14963 „N”","norm_bases":["PN-EN 14963 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pasma świetlne E Przepuszczalność powietrza PN-EN 14963 „N” Pasma swietlne E Przepuszczalnosc powietrza PN-EN 14963 „N”","categories":["other"],"row_index":450,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Continuous rooflights E Air permeability PN-EN 14963 „N”","methodology_zh":"透气性","search_zh":"带形采光带 E 透气性 PN-EN 14963 „N”","test_object_zh":"带形采光带 E"},{"_id":"6a5a55f19af9f73f382510d7","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Pasma świetlne E","test_object_en":"Continuous rooflights E","methodology":"Właściwości mechaniczne","methodology_en":"Mechanical properties","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Właściwości mechaniczne","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pasma świetlne E Właściwości mechaniczne Pasma swietlne E Wlasciwosci mechaniczne","categories":["other"],"row_index":451,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Continuous rooflights E Mechanical properties","methodology_zh":"力学性能","search_zh":"带形采光带 E 力学性能","test_object_zh":"带形采光带 E"},{"_id":"6a5a55f19af9f73f382510d8","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Pasma świetlne E","test_object_en":"Continuous rooflights E","methodology":"Wodoszczelność","methodology_en":"Watertightness","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pasma świetlne E Wodoszczelność Pasma swietlne E Wodoszczelnosc","categories":["other"],"row_index":452,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Continuous rooflights E Watertightness","methodology_zh":"不透水性","search_zh":"带形采光带 E 不透水性","test_object_zh":"带形采光带 E"},{"_id":"6a5a55f19af9f73f382510d9","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Pionowe elementy budowlane E","test_object_en":"Vertical building elements E","methodology":"Odporność na uderzenie","methodology_en":"Impact resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie","reference":"PN-93/B-10027","norm_bases":["PN-93/B-10027"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pionowe elementy budowlane E Odporność na uderzenie PN-93/B-10027 Pionowe elementy budowlane E Odpornosc na uderzenie PN-93/B-10027","categories":["construction"],"row_index":453,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Vertical building elements E Impact resistance PN-93/B-10027","methodology_zh":"耐冲击性","search_zh":"耐冲击性 PN-93/B-10027"},{"_id":"6a5a55f19af9f73f382510da","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Połączenia klejone E","test_object_en":"Adhesive-bonded joints E","methodology":"Odporność na oddzieranie pod kątem 90 stopni","methodology_en":"Peel resistance at 90 degrees","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na oddzieranie pod kątem 90 stopni","reference":"PN-EN 28510-1","norm_bases":["PN-EN 28510-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Połączenia klejone E Odporność na oddzieranie pod kątem 90 stopni PN-EN 28510-1 Polaczenia klejone E Odpornosc na oddzieranie pod katem 90 stopni PN-EN 28510-1","categories":["other"],"row_index":454,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Adhesive-bonded joints E Peel resistance at 90 degrees PN-EN 28510-1"},{"_id":"6a5a55f19af9f73f382510db","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Pomieszczenia i urządzenia do przechowywania wartości E","test_object_en":"Secure storage rooms and units for valuables E","methodology":"Odporność na atak z użyciem narzędzi","methodology_en":"Resistance to attack using tools","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na atak z użyciem narzędzi","reference":"PN-EN 14450","norm_bases":["PN-EN 14450"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomieszczenia i urządzenia do przechowywania wartości E Odporność na atak z użyciem narzędzi PN-EN 14450 Pomieszczenia i urzadzenia do przechowywania wartosci E Odpornosc na atak z uzyciem narzedzi PN-EN 14450","categories":["other"],"row_index":455,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Secure storage rooms and units for valuables E Resistance to attack using tools PN-EN 14450"},{"_id":"6a5a55f19af9f73f382510dc","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Pomieszczenia i urządzenia do przechowywania wartości E","test_object_en":"Secure storage rooms and units for valuables E","methodology":"Wytrzymałość mechaniczna kotwienia","methodology_en":"Mechanical strength of anchoring","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna kotwienia","reference":"PN-EN 14450","norm_bases":["PN-EN 14450"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomieszczenia i urządzenia do przechowywania wartości E Wytrzymałość mechaniczna kotwienia PN-EN 14450 Pomieszczenia i urzadzenia do przechowywania wartosci E Wytrzymalosc mechaniczna kotwienia PN-EN 14450","categories":["other"],"row_index":456,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Secure storage rooms and units for valuables E Mechanical strength of anchoring PN-EN 14450","methodology_zh":"锚固机械强度","search_zh":"锚固机械强度 PN-EN 14450"},{"_id":"6a5a55f19af9f73f382510dd","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Pomieszczenia i urządzenia do przechowywania wartości - zamki mechaniczne typu HSL E","test_object_en":"Secure storage units and rooms - mechanical locks of HSL type E","methodology":"Kodowalność","methodology_en":"Codability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Kodowalność","reference":"PN-EN 1300","norm_bases":["PN-EN 1300"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomieszczenia i urządzenia do przechowywania wartości - zamki mechaniczne typu HSL E Kodowalność PN-EN 1300 Pomieszczenia i urzadzenia do przechowywania wartosci - zamki mechaniczne typu HSL E Kodowalnosc PN-EN 1300","categories":["other"],"row_index":457,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Secure storage units and rooms - mechanical locks of HSL type E Codability PN-EN 1300","search_zh":"贵重物品存放房间与设备 － HSL 型机械锁 E PN-EN 1300","test_object_zh":"贵重物品存放房间与设备 － HSL 型机械锁 E"},{"_id":"6a5a55f19af9f73f382510de","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Pomieszczenia i urządzenia do przechowywania wartości - zamki mechaniczne typu HSL E","test_object_en":"Secure storage units and rooms - mechanical locks of HSL type E","methodology":"Odporność na manipulacje","methodology_en":"Tamper resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na manipulacje","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomieszczenia i urządzenia do przechowywania wartości - zamki mechaniczne typu HSL E Odporność na manipulacje Pomieszczenia i urzadzenia do przechowywania wartosci - zamki mechaniczne typu HSL E Odpornosc na manipulacje","categories":["other"],"row_index":458,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Secure storage units and rooms - mechanical locks of HSL type E Tamper resistance","search_zh":"贵重物品存放房间与设备 － HSL 型机械锁 E","test_object_zh":"贵重物品存放房间与设备 － HSL 型机械锁 E"},{"_id":"6a5a55f19af9f73f382510df","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Pomieszczenia i urządzenia do przechowywania wartości - zamki mechaniczne typu HSL E","test_object_en":"Secure storage units and rooms - mechanical locks of HSL type E","methodology":"Odporność na włamanie niszczące","methodology_en":"Resistance to destructive burglary","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na włamanie niszczące","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomieszczenia i urządzenia do przechowywania wartości - zamki mechaniczne typu HSL E Odporność na włamanie niszczące Pomieszczenia i urzadzenia do przechowywania wartosci - zamki mechaniczne typu HSL E Odpornosc na wlamanie niszczace","categories":["other"],"row_index":459,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Secure storage units and rooms - mechanical locks of HSL type E Resistance to destructive burglary","search_zh":"贵重物品存放房间与设备 － HSL 型机械锁 E","test_object_zh":"贵重物品存放房间与设备 － HSL 型机械锁 E"},{"_id":"6a5a55f19af9f73f382510e0","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Pomieszczenia i urządzenia do przechowywania wartości - zamki mechaniczne typu HSL E","test_object_en":"Secure storage units and rooms - mechanical locks of HSL type E","methodology":"Odporność na wstrząsy","methodology_en":"Shock resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na wstrząsy","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomieszczenia i urządzenia do przechowywania wartości - zamki mechaniczne typu HSL E Odporność na wstrząsy Pomieszczenia i urzadzenia do przechowywania wartosci - zamki mechaniczne typu HSL E Odpornosc na wstrzasy","categories":["other"],"row_index":460,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Secure storage units and rooms - mechanical locks of HSL type E Shock resistance","search_zh":"贵重物品存放房间与设备 － HSL 型机械锁 E 耐振动性","test_object_zh":"贵重物品存放房间与设备 － HSL 型机械锁 E","methodology_zh":"耐振动性"},{"_id":"6a5a55f19af9f73f382510e1","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Pomieszczenia i urządzenia do przechowywania wartości - zamki mechaniczne typu HSL E","test_object_en":"Secure storage units and rooms - mechanical locks of HSL type E","methodology":"Powtarzalność","methodology_en":"Repeatability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Powtarzalność","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomieszczenia i urządzenia do przechowywania wartości - zamki mechaniczne typu HSL E Powtarzalność Pomieszczenia i urzadzenia do przechowywania wartosci - zamki mechaniczne typu HSL E Powtarzalnosc","categories":["other"],"row_index":461,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Secure storage units and rooms - mechanical locks of HSL type E Repeatability","search_zh":"贵重物品存放房间与设备 － HSL 型机械锁 E","test_object_zh":"贵重物品存放房间与设备 － HSL 型机械锁 E"},{"_id":"6a5a55f19af9f73f382510e2","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Powłoki E","test_object_en":"Coatings E","methodology":"Grubość powłoki + Minitest Zakres: (0 - 500) µm Metoda magnetyczna","methodology_en":"Coating thickness + Minitest Range: (0 - 500) µm Magnetic method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Grubość powłoki + Minitest Zakres: (0 - 500) µm Metoda magnetyczna","reference":"PN-EN ISO 2178 PN-EN ISO 2360 PN-EN ISO 2808","norm_bases":["PN-EN ISO 2178 PN-EN ISO 2360 PN-EN ISO 2808"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki E Grubość powłoki + Minitest Zakres: (0 - 500) µm Metoda magnetyczna PN-EN ISO 2178 PN-EN ISO 2360 PN-EN ISO 2808 Powloki E Grubosc powloki + Minitest Zakres: (0 - 500) µm Metoda magnetyczna PN-EN ISO 2178 PN-EN ISO 2360 PN-EN ISO 2808","categories":["other"],"row_index":462,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coatings E Coating thickness + Minitest Range: (0 - 500) µm Magnetic method PN-EN ISO 2178 PN-EN ISO 2360 PN-EN ISO 2808","search_zh":"涂层 E PN-EN ISO 2178 PN-EN ISO 2360 PN-EN ISO 2808","test_object_zh":"涂层 E"},{"_id":"6a5a55f19af9f73f382510e3","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Powłoki E","test_object_en":"Coatings E","methodology":"Odporność korozyjna w obojętnej mgle solnej. Metoda NSS","methodology_en":"Corrosion resistance in neutral salt spray. NSS method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność korozyjna w obojętnej mgle solnej. Metoda NSS","reference":"PN-EN ISO 9227","norm_bases":["PN-EN ISO 9227"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki E Odporność korozyjna w obojętnej mgle solnej. Metoda NSS PN-EN ISO 9227 Powloki E Odpornosc korozyjna w obojetnej mgle solnej. Metoda NSS PN-EN ISO 9227","categories":["other"],"row_index":463,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coatings E Corrosion resistance in neutral salt spray. NSS method PN-EN ISO 9227","search_zh":"涂层 E PN-EN ISO 9227","test_object_zh":"涂层 E"},{"_id":"6a5a55f19af9f73f382510e4","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Powłoki E","test_object_en":"Coatings E","methodology":"Odporność na oderwanie od podłoża + Metoda siatki nacięć noże krążkowe o rozstawie ostrzy 1 mm, 2 mm, 3 mm.","methodology_en":"Resistance to detachment from the substrate + Cross-cut method cutting wheels with blade spacing of 1 mm, 2 mm, 3 mm.","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na oderwanie od podłoża + Metoda siatki nacięć noże krążkowe o rozstawie ostrzy 1 mm, 2 mm, 3 mm.","reference":"PN-EN ISO 2409","norm_bases":["PN-EN ISO 2409"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki E Odporność na oderwanie od podłoża + Metoda siatki nacięć noże krążkowe o rozstawie ostrzy 1 mm, 2 mm, 3 mm. PN-EN ISO 2409 Powloki E Odpornosc na oderwanie od podloza + Metoda siatki naciec noze krazkowe o rozstawie ostrzy 1 mm, 2 mm, 3 mm. PN-EN ISO 2409","categories":["other"],"row_index":464,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coatings E Resistance to detachment from the substrate + Cross-cut method cutting wheels with blade spacing of 1 mm, 2 mm, 3 mm. PN-EN ISO 2409","search_zh":"涂层 E PN-EN ISO 2409","test_object_zh":"涂层 E"},{"_id":"6a5a55f19af9f73f382510e5","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Powłoki E","test_object_en":"Coatings E","methodology":"Zginanie +","methodology_en":"Bending +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zginanie +","reference":"PN-EN ISO 1519","norm_bases":["PN-EN ISO 1519"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki E Zginanie + PN-EN ISO 1519 Powloki E Zginanie + PN-EN ISO 1519","categories":["other"],"row_index":465,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coatings E Bending + PN-EN ISO 1519","search_zh":"涂层 E PN-EN ISO 1519","test_object_zh":"涂层 E"},{"_id":"6a5a55f19af9f73f382510e6","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Ręczne kurki (zawory) kulowe do instalacji wodociągowych E","test_object_en":"Manually operated ball valves for water supply installations E","methodology":"Moment napędowy","methodology_en":"Driving torque","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moment napędowy","reference":"PN-EN 13828","norm_bases":["PN-EN 13828"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ręczne kurki (zawory) kulowe do instalacji wodociągowych E Moment napędowy PN-EN 13828 Reczne kurki (zawory) kulowe do instalacji wodociagowych E Moment napedowy PN-EN 13828","categories":["water"],"row_index":466,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Manually operated ball valves for water supply installations E Driving torque PN-EN 13828","search_zh":"给水装置用手动球阀 E 驱动力矩 PN-EN 13828","test_object_zh":"给水装置用手动球阀 E","methodology_zh":"驱动力矩"},{"_id":"6a5a55f19af9f73f382510e7","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Ręczne kurki (zawory) kulowe do instalacji wodociągowych E","test_object_en":"Manually operated ball valves for water supply installations E","methodology":"Wytrzymałość na skręcanie i zginanie","methodology_en":"Torsional and flexural strength","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na skręcanie i zginanie","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ręczne kurki (zawory) kulowe do instalacji wodociągowych E Wytrzymałość na skręcanie i zginanie Reczne kurki (zawory) kulowe do instalacji wodociagowych E Wytrzymalosc na skrecanie i zginanie","categories":["water"],"row_index":467,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Manually operated ball valves for water supply installations E Torsional and flexural strength","search_zh":"给水装置用手动球阀 E","test_object_zh":"给水装置用手动球阀 E"},{"_id":"6a5a55f19af9f73f382510e8","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Ręczne kurki (zawory) kulowe do instalacji wodociągowych E","test_object_en":"Manually operated ball valves for water supply installations E","methodology":"Wytrzymałość ograniczników","methodology_en":"Strength of stops","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość ograniczników","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ręczne kurki (zawory) kulowe do instalacji wodociągowych E Wytrzymałość ograniczników Reczne kurki (zawory) kulowe do instalacji wodociagowych E Wytrzymalosc ogranicznikow","categories":["water"],"row_index":468,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Manually operated ball valves for water supply installations E Strength of stops","search_zh":"给水装置用手动球阀 E","test_object_zh":"给水装置用手动球阀 E"},{"_id":"6a5a55f19af9f73f382510e9","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Ręczne kurki (zawory) kulowe do instalacji wodociągowych E","test_object_en":"Manually operated ball valves for water supply installations E","methodology":"Szczelność hydrauliczna","methodology_en":"Hydraulic tightness","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność hydrauliczna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ręczne kurki (zawory) kulowe do instalacji wodociągowych E Szczelność hydrauliczna Reczne kurki (zawory) kulowe do instalacji wodociagowych E Szczelnosc hydrauliczna","categories":["water"],"row_index":469,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Manually operated ball valves for water supply installations E Hydraulic tightness","search_zh":"给水装置用手动球阀 E","test_object_zh":"给水装置用手动球阀 E"},{"_id":"6a5a55f19af9f73f382510ea","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Ręczne kurki (zawory) kulowe do instalacji wodociągowych E","test_object_en":"Manually operated ball valves for water supply installations E","methodology":"Wytrzymałość hydrauliczna","methodology_en":"Hydraulic strength","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość hydrauliczna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ręczne kurki (zawory) kulowe do instalacji wodociągowych E Wytrzymałość hydrauliczna Reczne kurki (zawory) kulowe do instalacji wodociagowych E Wytrzymalosc hydrauliczna","categories":["water"],"row_index":470,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Manually operated ball valves for water supply installations E Hydraulic strength","search_zh":"给水装置用手动球阀 E","test_object_zh":"给水装置用手动球阀 E"},{"_id":"6a5a55f19af9f73f382510eb","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Ręczne kurki (zawory) kulowe do instalacji wodociągowych E","test_object_en":"Manually operated ball valves for water supply installations E","methodology":"Trwałość","methodology_en":"Durability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ręczne kurki (zawory) kulowe do instalacji wodociągowych E Trwałość Reczne kurki (zawory) kulowe do instalacji wodociagowych E Trwalosc","categories":["water"],"row_index":471,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Manually operated ball valves for water supply installations E Durability","methodology_zh":"耐久性","search_zh":"给水装置用手动球阀 E 耐久性","test_object_zh":"给水装置用手动球阀 E"},{"_id":"6a5a55f19af9f73f382510ec","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Rury i kształtki wtryskowe z termoplastycznych tworzyw sztucznych E","test_object_en":"Injection-moulded thermoplastic pipes and fittings E","methodology":"Odporność na uderzenie Metoda spadającego ciężarka Typ d25 i d90 Zakres: do 3,2 kg","methodology_en":"Impact resistance Falling weight method Type d25 and d90 Range: up to 3,2 kg","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie Metoda spadającego ciężarka Typ d25 i d90 Zakres: do 3,2 kg","reference":"PN-EN 744","norm_bases":["PN-EN 744"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury i kształtki wtryskowe z termoplastycznych tworzyw sztucznych E Odporność na uderzenie Metoda spadającego ciężarka Typ d25 i d90 Zakres: do 3,2 kg PN-EN 744 Rury i ksztaltki wtryskowe z termoplastycznych tworzyw sztucznych E Odpornosc na uderzenie Metoda spadajacego ciezarka Typ d25 i d90 Zakres: do 3,2 kg PN-EN 744","categories":["other"],"row_index":472,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Injection-moulded thermoplastic pipes and fittings E Impact resistance Falling weight method Type d25 and d90 Range: up to 3,2 kg PN-EN 744","search_zh":"热塑性塑料注塑管材与管件 E PN-EN 744","test_object_zh":"热塑性塑料注塑管材与管件 E"},{"_id":"6a5a55f19af9f73f382510ed","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Rury i kształtki wtryskowe z termoplastycznych tworzyw sztucznych E","test_object_en":"Injection-moulded thermoplastic pipes and fittings E","methodology":"Odporność na uderzenie","methodology_en":"Impact resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie","reference":"PN-EN 607","norm_bases":["PN-EN 607"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury i kształtki wtryskowe z termoplastycznych tworzyw sztucznych E Odporność na uderzenie PN-EN 607 Rury i ksztaltki wtryskowe z termoplastycznych tworzyw sztucznych E Odpornosc na uderzenie PN-EN 607","categories":["other"],"row_index":473,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Injection-moulded thermoplastic pipes and fittings E Impact resistance PN-EN 607","methodology_zh":"耐冲击性","search_zh":"热塑性塑料注塑管材与管件 E 耐冲击性 PN-EN 607","test_object_zh":"热塑性塑料注塑管材与管件 E"},{"_id":"6a5a55f19af9f73f382510ee","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Rury i kształtki wtryskowe z termoplastycznych tworzyw sztucznych E","test_object_en":"Injection-moulded thermoplastic pipes and fittings E","methodology":"Właściwości mechaniczne przy rozciąganiu","methodology_en":"Tensile mechanical properties","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Właściwości mechaniczne przy rozciąganiu","reference":"PN-EN ISO 6259-1","norm_bases":["PN-EN ISO 6259-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury i kształtki wtryskowe z termoplastycznych tworzyw sztucznych E Właściwości mechaniczne przy rozciąganiu PN-EN ISO 6259-1 Rury i ksztaltki wtryskowe z termoplastycznych tworzyw sztucznych E Wlasciwosci mechaniczne przy rozciaganiu PN-EN ISO 6259-1","categories":["other"],"row_index":474,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Injection-moulded thermoplastic pipes and fittings E Tensile mechanical properties PN-EN ISO 6259-1","methodology_zh":"拉伸力学性能","search_zh":"热塑性塑料注塑管材与管件 E 拉伸力学性能 PN-EN ISO 6259-1","test_object_zh":"热塑性塑料注塑管材与管件 E"},{"_id":"6a5a55f19af9f73f382510ef","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Rury i kształtki wtryskowe z termoplastycznych tworzyw sztucznych E","test_object_en":"Injection-moulded thermoplastic pipes and fittings E","methodology":"Zmiany w wyniku ogrzewania","methodology_en":"Changes after heating","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zmiany w wyniku ogrzewania","reference":"PN-EN ISO 580","norm_bases":["PN-EN ISO 580"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury i kształtki wtryskowe z termoplastycznych tworzyw sztucznych E Zmiany w wyniku ogrzewania PN-EN ISO 580 Rury i ksztaltki wtryskowe z termoplastycznych tworzyw sztucznych E Zmiany w wyniku ogrzewania PN-EN ISO 580","categories":["other"],"row_index":475,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Injection-moulded thermoplastic pipes and fittings E Changes after heating PN-EN ISO 580","search_zh":"热塑性塑料注塑管材与管件 E PN-EN ISO 580","test_object_zh":"热塑性塑料注塑管材与管件 E"},{"_id":"6a5a55f19af9f73f382510f0","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stopnie do studzienek włazowych E","test_object_en":"Step irons for manholes E","methodology":"Grubość powłoki z tworzywa sztucznego","methodology_en":"Thickness of the plastic coating","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Grubość powłoki z tworzywa sztucznego","reference":"PN-EN 13101","norm_bases":["PN-EN 13101"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stopnie do studzienek włazowych E Grubość powłoki z tworzywa sztucznego PN-EN 13101 Stopnie do studzienek wlazowych E Grubosc powloki z tworzywa sztucznego PN-EN 13101","categories":["materials"],"row_index":476,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Step irons for manholes E Thickness of the plastic coating PN-EN 13101","search_zh":"检查井踏步 E PN-EN 13101","test_object_zh":"检查井踏步 E"},{"_id":"6a5a55f19af9f73f382510f1","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stopnie do studzienek włazowych E","test_object_en":"Step irons for manholes E","methodology":"Odporność na uderzenie","methodology_en":"Impact resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stopnie do studzienek włazowych E Odporność na uderzenie Stopnie do studzienek wlazowych E Odpornosc na uderzenie","categories":["other"],"row_index":477,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Step irons for manholes E Impact resistance","methodology_zh":"耐冲击性","search_zh":"检查井踏步 E 耐冲击性","test_object_zh":"检查井踏步 E"},{"_id":"6a5a55f19af9f73f382510f2","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stopnie do studzienek włazowych E","test_object_en":"Step irons for manholes E","methodology":"Wytrzymałość na obciążenie pionowe","methodology_en":"Resistance to vertical load","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na obciążenie pionowe","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stopnie do studzienek włazowych E Wytrzymałość na obciążenie pionowe Stopnie do studzienek wlazowych E Wytrzymalosc na obciazenie pionowe","categories":["other"],"row_index":478,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Step irons for manholes E Resistance to vertical load","search_zh":"检查井踏步 E","test_object_zh":"检查井踏步 E"},{"_id":"6a5a55f19af9f73f382510f3","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stopnie do studzienek włazowych E","test_object_en":"Step irons for manholes E","methodology":"Wytrzymałość na obciążenie stopni z żeliwa szarego","methodology_en":"Load resistance of grey cast iron steps","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na obciążenie stopni z żeliwa szarego","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stopnie do studzienek włazowych E Wytrzymałość na obciążenie stopni z żeliwa szarego Stopnie do studzienek wlazowych E Wytrzymalosc na obciazenie stopni z zeliwa szarego","categories":["other"],"row_index":479,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Step irons for manholes E Load resistance of grey cast iron steps","search_zh":"检查井踏步 E","test_object_zh":"检查井踏步 E"},{"_id":"6a5a55f19af9f73f382510f4","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stopnie do studzienek włazowych E","test_object_en":"Step irons for manholes E","methodology":"Wytrzymałość na wyrywanie","methodology_en":"Pull-out strength","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na wyrywanie","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stopnie do studzienek włazowych E Wytrzymałość na wyrywanie Stopnie do studzienek wlazowych E Wytrzymalosc na wyrywanie","categories":["other"],"row_index":480,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Step irons for manholes E Pull-out strength","search_zh":"检查井踏步 E","test_object_zh":"检查井踏步 E"},{"_id":"6a5a55f19af9f73f382510f5","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stopnie do studzienek włazowych E","test_object_en":"Step irons for manholes E","methodology":"Zwichrowanie","methodology_en":"Warping","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zwichrowanie","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stopnie do studzienek włazowych E Zwichrowanie Stopnie do studzienek wlazowych E Zwichrowanie","categories":["other"],"row_index":481,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Step irons for manholes E Warping","search_zh":"检查井踏步 E","test_object_zh":"检查井踏步 E"},{"_id":"6a5a55f19af9f73f382510f6","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Ściany osłonowe E","test_object_en":"Curtain walling E","methodology":"Odporność na włamanie – próba włamania ręcznego","methodology_en":"Burglary resistance – manual burglary attack test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na włamanie – próba włamania ręcznego","reference":"PN-EN 1630","norm_bases":["PN-EN 1630"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ściany osłonowe E Odporność na włamanie – próba włamania ręcznego PN-EN 1630 Sciany oslonowe E Odpornosc na wlamanie – proba wlamania recznego PN-EN 1630","categories":["other"],"row_index":482,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Curtain walling E Burglary resistance – manual burglary attack test PN-EN 1630","search_zh":"幕墙 E PN-EN 1630","test_object_zh":"幕墙 E"},{"_id":"6a5a55f19af9f73f382510f7","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Ściany osłonowe E","test_object_en":"Curtain walling E","methodology":"Odporność na włamanie przy obciążeniu dynamicznym","methodology_en":"Burglar resistance under dynamic load","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na włamanie przy obciążeniu dynamicznym","reference":"PN-EN 1629","norm_bases":["PN-EN 1629"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ściany osłonowe E Odporność na włamanie przy obciążeniu dynamicznym PN-EN 1629 Sciany oslonowe E Odpornosc na wlamanie przy obciazeniu dynamicznym PN-EN 1629","categories":["other"],"row_index":483,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Curtain walling E Burglar resistance under dynamic load PN-EN 1629","methodology_zh":"动荷载下的抗侵入性","search_zh":"幕墙 E 动荷载下的抗侵入性 PN-EN 1629","test_object_zh":"幕墙 E"},{"_id":"6a5a55f19af9f73f382510f8","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Ściany osłonowe E","test_object_en":"Curtain walling E","methodology":"Odporność na włamanie przy obciążeniu statycznym","methodology_en":"Burglar resistance under static loading","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na włamanie przy obciążeniu statycznym","reference":"PN-EN 1628","norm_bases":["PN-EN 1628"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ściany osłonowe E Odporność na włamanie przy obciążeniu statycznym PN-EN 1628 Sciany oslonowe E Odpornosc na wlamanie przy obciazeniu statycznym PN-EN 1628","categories":["other"],"row_index":484,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Curtain walling E Burglar resistance under static loading PN-EN 1628","methodology_zh":"静荷载下的抗侵入性","search_zh":"幕墙 E 静荷载下的抗侵入性 PN-EN 1628","test_object_zh":"幕墙 E"},{"_id":"6a5a55f19af9f73f382510f9","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Świetliki, pasma świetlne, wyłazy dachowe E","test_object_en":"Rooflights, continuous rooflights, roof hatches E","methodology":"Odporność na włamanie – próba włamania ręcznego","methodology_en":"Burglary resistance – manual burglary attack test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na włamanie – próba włamania ręcznego","reference":"LOW-019 | PN-EN 1630","norm_bases":["LOW-019","PN-EN 1630"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Świetliki, pasma świetlne, wyłazy dachowe E Odporność na włamanie – próba włamania ręcznego LOW-019 | PN-EN 1630 Swietliki, pasma swietlne, wylazy dachowe E Odpornosc na wlamanie – proba wlamania recznego LOW-019 | PN-EN 1630","categories":["construction"],"row_index":485,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooflights, continuous rooflights, roof hatches E Burglary resistance – manual burglary attack test LOW-019 | PN-EN 1630"},{"_id":"6a5a55f19af9f73f382510fa","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Świetliki, pasma świetlne, wyłazy dachowe E","test_object_en":"Rooflights, continuous rooflights, roof hatches E","methodology":"Odporność na włamanie przy obciążeniu dynamicznym","methodology_en":"Burglar resistance under dynamic load","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na włamanie przy obciążeniu dynamicznym","reference":"LOW-019 | PN-EN 1629","norm_bases":["LOW-019","PN-EN 1629"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Świetliki, pasma świetlne, wyłazy dachowe E Odporność na włamanie przy obciążeniu dynamicznym LOW-019 | PN-EN 1629 Swietliki, pasma swietlne, wylazy dachowe E Odpornosc na wlamanie przy obciazeniu dynamicznym LOW-019 | PN-EN 1629","categories":["construction"],"row_index":486,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooflights, continuous rooflights, roof hatches E Burglar resistance under dynamic load LOW-019 | PN-EN 1629","methodology_zh":"动荷载下的抗侵入性","search_zh":"动荷载下的抗侵入性 LOW-019 | PN-EN 1629"},{"_id":"6a5a55f19af9f73f382510fb","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Świetliki E","test_object_en":"Rooflights E","methodology":"Właściwości mechaniczne","methodology_en":"Mechanical properties","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Właściwości mechaniczne","reference":"PN-EN 1873 „N” EAD 220021-00-0402","norm_bases":["PN-EN 1873 „N” EAD 220021-00-0402"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Świetliki E Właściwości mechaniczne PN-EN 1873 „N” EAD 220021-00-0402 Swietliki E Wlasciwosci mechaniczne PN-EN 1873 „N” EAD 220021-00-0402","categories":["other"],"row_index":487,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooflights E Mechanical properties PN-EN 1873 „N” EAD 220021-00-0402","methodology_zh":"力学性能","search_zh":"采光天窗 E 力学性能 PN-EN 1873 „N” EAD 220021-00-0402","test_object_zh":"采光天窗 E"},{"_id":"6a5a55f19af9f73f382510fc","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Świetliki E","test_object_en":"Rooflights E","methodology":"Przepuszczalność powietrza","methodology_en":"Air permeability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność powietrza","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Świetliki E Przepuszczalność powietrza Swietliki E Przepuszczalnosc powietrza","categories":["other"],"row_index":488,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooflights E Air permeability","methodology_zh":"透气性","search_zh":"采光天窗 E 透气性","test_object_zh":"采光天窗 E"},{"_id":"6a5a55f19af9f73f382510fd","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Świetliki E","test_object_en":"Rooflights E","methodology":"Wodoszczelność","methodology_en":"Watertightness","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Świetliki E Wodoszczelność Swietliki E Wodoszczelnosc","categories":["other"],"row_index":489,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooflights E Watertightness","methodology_zh":"不透水性","search_zh":"采光天窗 E 不透水性","test_object_zh":"采光天窗 E"},{"_id":"6a5a55f19af9f73f382510fe","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Uchwyty do rynien okapowych E","test_object_en":"Eaves gutter brackets E","methodology":"Nośność","methodology_en":"Load-bearing capacity","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność","reference":"PN-EN 1462","norm_bases":["PN-EN 1462"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Uchwyty do rynien okapowych E Nośność PN-EN 1462 Uchwyty do rynien okapowych E Nosnosc PN-EN 1462","categories":["other"],"row_index":490,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Eaves gutter brackets E Load-bearing capacity PN-EN 1462","methodology_zh":"承载力","search_zh":"承载力 PN-EN 1462"},{"_id":"6a5a55f19af9f73f382510ff","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Uchwyty do systemów przewodowych stosowanych do odprowadzania wody deszczowej E","test_object_en":"Brackets for piping systems used for rainwater drainage E","methodology":"Wytrzymałość uchwytów","methodology_en":"Strength of handles","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość uchwytów","reference":"PN-EN 12095","norm_bases":["PN-EN 12095"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Uchwyty do systemów przewodowych stosowanych do odprowadzania wody deszczowej E Wytrzymałość uchwytów PN-EN 12095 Uchwyty do systemow przewodowych stosowanych do odprowadzania wody deszczowej E Wytrzymalosc uchwytow PN-EN 12095","categories":["water"],"row_index":491,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Brackets for piping systems used for rainwater drainage E Strength of handles PN-EN 12095"},{"_id":"6a5a55f19af9f73f38251100","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Umywalki E","test_object_en":"Washbasins E","methodology":"Ochrona przed przepełnieniem","methodology_en":"Overfill protection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ochrona przed przepełnieniem","reference":"PN-EN 14688","norm_bases":["PN-EN 14688"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Umywalki E Ochrona przed przepełnieniem PN-EN 14688 Umywalki E Ochrona przed przepelnieniem PN-EN 14688","categories":["other"],"row_index":492,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Washbasins E Overfill protection PN-EN 14688","search_zh":"洗面盆 E PN-EN 14688","test_object_zh":"洗面盆 E"},{"_id":"6a5a55f19af9f73f38251101","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Umywalki E","test_object_en":"Washbasins E","methodology":"Odporność na odczynniki chemiczne","methodology_en":"Resistance to chemical reagents","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na odczynniki chemiczne","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Umywalki E Odporność na odczynniki chemiczne Umywalki E Odpornosc na odczynniki chemiczne","categories":["other"],"row_index":493,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Washbasins E Resistance to chemical reagents","search_zh":"洗面盆 E","test_object_zh":"洗面盆 E"},{"_id":"6a5a55f19af9f73f38251102","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Umywalki E","test_object_en":"Washbasins E","methodology":"Odporność na zmiany temperatury","methodology_en":"Resistance to temperature changes","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zmiany temperatury","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Umywalki E Odporność na zmiany temperatury Umywalki E Odpornosc na zmiany temperatury","categories":["other"],"row_index":494,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Washbasins E Resistance to temperature changes","methodology_zh":"耐温度变化性","search_zh":"洗面盆 E 耐温度变化性","test_object_zh":"洗面盆 E"},{"_id":"6a5a55f19af9f73f38251103","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Umywalki E","test_object_en":"Washbasins E","methodology":"Odprowadzenie wody","methodology_en":"Water drainage","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odprowadzenie wody","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Umywalki E Odprowadzenie wody Umywalki E Odprowadzenie wody","categories":["water"],"row_index":495,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Washbasins E Water drainage","search_zh":"洗面盆 E","test_object_zh":"洗面盆 E"},{"_id":"6a5a55f19af9f73f38251104","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Umywalki E","test_object_en":"Washbasins E","methodology":"Zdolność do czyszczenia","methodology_en":"Cleanability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność do czyszczenia","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Umywalki E Zdolność do czyszczenia Umywalki E Zdolnosc do czyszczenia","categories":["other"],"row_index":496,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Washbasins E Cleanability","search_zh":"洗面盆 E","test_object_zh":"洗面盆 E"},{"_id":"6a5a55f19af9f73f38251105","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Uszczelki i taśmy uszczelniające E","test_object_en":"Gaskets and sealing tapes E","methodology":"Liniowa siła ściskająca","methodology_en":"Linear compressive force","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liniowa siła ściskająca","reference":"PN-EN 12365-2","norm_bases":["PN-EN 12365-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Uszczelki i taśmy uszczelniające E Liniowa siła ściskająca PN-EN 12365-2 Uszczelki i tasmy uszczelniajace E Liniowa sila sciskajaca PN-EN 12365-2","categories":["other"],"row_index":497,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gaskets and sealing tapes E Linear compressive force PN-EN 12365-2","search_zh":"密封件与密封胶带 E PN-EN 12365-2","test_object_zh":"密封件与密封胶带 E"},{"_id":"6a5a55f19af9f73f38251106","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Uszczelki i taśmy uszczelniające E","test_object_en":"Gaskets and sealing tapes E","methodology":"Powrót poodkształceniowy po przyspieszonym starzeniu","methodology_en":"Recovery after deformation following accelerated ageing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Powrót poodkształceniowy po przyspieszonym starzeniu","reference":"PN-EN 12365-4","norm_bases":["PN-EN 12365-4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Uszczelki i taśmy uszczelniające E Powrót poodkształceniowy po przyspieszonym starzeniu PN-EN 12365-4 Uszczelki i tasmy uszczelniajace E Powrot poodksztalceniowy po przyspieszonym starzeniu PN-EN 12365-4","categories":["other"],"row_index":498,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gaskets and sealing tapes E Recovery after deformation following accelerated ageing PN-EN 12365-4","search_zh":"密封件与密封胶带 E PN-EN 12365-4","test_object_zh":"密封件与密封胶带 E"},{"_id":"6a5a55f19af9f73f38251107","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Uszczelki i taśmy uszczelniające E","test_object_en":"Gaskets and sealing tapes E","methodology":"Powrót poodkształceniowy","methodology_en":"Recovery after deformation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Powrót poodkształceniowy","reference":"PN-EN 12365-3","norm_bases":["PN-EN 12365-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Uszczelki i taśmy uszczelniające E Powrót poodkształceniowy PN-EN 12365-3 Uszczelki i tasmy uszczelniajace E Powrot poodksztalceniowy PN-EN 12365-3","categories":["other"],"row_index":499,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gaskets and sealing tapes E Recovery after deformation PN-EN 12365-3","search_zh":"密封件与密封胶带 E PN-EN 12365-3","test_object_zh":"密封件与密封胶带 E"},{"_id":"6a5a55f19af9f73f38251108","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wanny E","test_object_en":"Baths E","methodology":"Odporność na działanie środków chemicznych","methodology_en":"Resistance to chemical agents","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie środków chemicznych","reference":"PN-EN 198 PN-EN 14516","norm_bases":["PN-EN 198 PN-EN 14516"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wanny E Odporność na działanie środków chemicznych PN-EN 198 PN-EN 14516 Wanny E Odpornosc na dzialanie srodkow chemicznych PN-EN 198 PN-EN 14516","categories":["other"],"row_index":500,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Baths E Resistance to chemical agents PN-EN 198 PN-EN 14516","search_zh":"浴缸 E PN-EN 198 PN-EN 14516","test_object_zh":"浴缸 E"},{"_id":"6a5a55f19af9f73f38251109","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wanny E","test_object_en":"Baths E","methodology":"Odporność na uderzenia mechaniczne","methodology_en":"Resistance to mechanical impacts","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenia mechaniczne","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wanny E Odporność na uderzenia mechaniczne Wanny E Odpornosc na uderzenia mechaniczne","categories":["other"],"row_index":501,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Baths E Resistance to mechanical impacts","methodology_zh":"耐机械撞击性","search_zh":"浴缸 E 耐机械撞击性","test_object_zh":"浴缸 E"},{"_id":"6a5a55f19af9f73f3825110a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wanny E","test_object_en":"Baths E","methodology":"Odporność na zmiany temperatury","methodology_en":"Resistance to temperature changes","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zmiany temperatury","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wanny E Odporność na zmiany temperatury Wanny E Odpornosc na zmiany temperatury","categories":["other"],"row_index":502,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Baths E Resistance to temperature changes","methodology_zh":"耐温度变化性","search_zh":"浴缸 E 耐温度变化性","test_object_zh":"浴缸 E"},{"_id":"6a5a55f19af9f73f3825110b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wkładki bębenkowe mechatroniczne E","test_object_en":"Mechatronic cylinders E","methodology":"Siły i momenty operacyjne","methodology_en":"Operating forces and torques","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siły i momenty operacyjne","reference":"PN-EN 15684","norm_bases":["PN-EN 15684"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkładki bębenkowe mechatroniczne E Siły i momenty operacyjne PN-EN 15684 Wkladki bebenkowe mechatroniczne E Sily i momenty operacyjne PN-EN 15684","categories":["other"],"row_index":503,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mechatronic cylinders E Operating forces and torques PN-EN 15684","search_zh":"机电圆柱锁芯 E PN-EN 15684","test_object_zh":"机电圆柱锁芯 E"},{"_id":"6a5a55f19af9f73f3825110c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wkładki bębenkowe mechatroniczne E","test_object_en":"Mechatronic cylinders E","methodology":"Trwałość","methodology_en":"Durability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkładki bębenkowe mechatroniczne E Trwałość Wkladki bebenkowe mechatroniczne E Trwalosc","categories":["other"],"row_index":504,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mechatronic cylinders E Durability","methodology_zh":"耐久性","search_zh":"机电圆柱锁芯 E 耐久性","test_object_zh":"机电圆柱锁芯 E"},{"_id":"6a5a55f19af9f73f3825110d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wkładki bębenkowe mechatroniczne E","test_object_en":"Mechatronic cylinders E","methodology":"Odporność na korozję","methodology_en":"Corrosion resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na korozję","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkładki bębenkowe mechatroniczne E Odporność na korozję Wkladki bebenkowe mechatroniczne E Odpornosc na korozje","categories":["other"],"row_index":505,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mechatronic cylinders E Corrosion resistance","methodology_zh":"耐腐蚀性","search_zh":"机电圆柱锁芯 E 耐腐蚀性","test_object_zh":"机电圆柱锁芯 E"},{"_id":"6a5a55f19af9f73f3825110e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wkładki bębenkowe mechatroniczne E","test_object_en":"Mechatronic cylinders E","methodology":"Odporność na działanie momentu obrotowego","methodology_en":"Resistance to torque","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie momentu obrotowego","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkładki bębenkowe mechatroniczne E Odporność na działanie momentu obrotowego Wkladki bebenkowe mechatroniczne E Odpornosc na dzialanie momentu obrotowego","categories":["other"],"row_index":506,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mechatronic cylinders E Resistance to torque","search_zh":"机电圆柱锁芯 E","test_object_zh":"机电圆柱锁芯 E"},{"_id":"6a5a55f19af9f73f3825110f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wkładki bębenkowe mechatroniczne E","test_object_en":"Mechatronic cylinders E","methodology":"Odporność na wiercenie","methodology_en":"Resistance to drilling","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na wiercenie","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkładki bębenkowe mechatroniczne E Odporność na wiercenie Wkladki bebenkowe mechatroniczne E Odpornosc na wiercenie","categories":["other"],"row_index":507,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mechatronic cylinders E Resistance to drilling","search_zh":"机电圆柱锁芯 E","test_object_zh":"机电圆柱锁芯 E"},{"_id":"6a5a55f19af9f73f38251110","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wkładki bębenkowe mechatroniczne E","test_object_en":"Mechatronic cylinders E","methodology":"Odporność na atak przecinakiem","methodology_en":"Resistance to chisel attack","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na atak przecinakiem","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkładki bębenkowe mechatroniczne E Odporność na atak przecinakiem Wkladki bebenkowe mechatroniczne E Odpornosc na atak przecinakiem","categories":["other"],"row_index":508,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mechatronic cylinders E Resistance to chisel attack","search_zh":"机电圆柱锁芯 E 抗凿击性","test_object_zh":"机电圆柱锁芯 E","methodology_zh":"抗凿击性"},{"_id":"6a5a55f19af9f73f38251111","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wkładki bębenkowe mechatroniczne E","test_object_en":"Mechatronic cylinders E","methodology":"Odporność na atak przez ukręcenie","methodology_en":"Resistance to attack by twisting off","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na atak przez ukręcenie","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkładki bębenkowe mechatroniczne E Odporność na atak przez ukręcenie Wkladki bebenkowe mechatroniczne E Odpornosc na atak przez ukrecenie","categories":["other"],"row_index":509,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mechatronic cylinders E Resistance to attack by twisting off","search_zh":"机电圆柱锁芯 E","test_object_zh":"机电圆柱锁芯 E"},{"_id":"6a5a55f19af9f73f38251112","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wkładki bębenkowe mechatroniczne E","test_object_en":"Mechatronic cylinders E","methodology":"Odporność na atak przez wyrywanie","methodology_en":"Resistance to attack by pulling out","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na atak przez wyrywanie","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkładki bębenkowe mechatroniczne E Odporność na atak przez wyrywanie Wkladki bebenkowe mechatroniczne E Odpornosc na atak przez wyrywanie","categories":["other"],"row_index":510,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mechatronic cylinders E Resistance to attack by pulling out","search_zh":"机电圆柱锁芯 E","test_object_zh":"机电圆柱锁芯 E"},{"_id":"6a5a55f19af9f73f38251113","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wkładki bębenkowe mechatroniczne E","test_object_en":"Mechatronic cylinders E","methodology":"Odporność na atak przez uderzenia (ręczne)","methodology_en":"Resistance to attack by impact (manual)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na atak przez uderzenia (ręczne)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkładki bębenkowe mechatroniczne E Odporność na atak przez uderzenia (ręczne) Wkladki bebenkowe mechatroniczne E Odpornosc na atak przez uderzenia (reczne)","categories":["other"],"row_index":511,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mechatronic cylinders E Resistance to attack by impact (manual)","search_zh":"机电圆柱锁芯 E","test_object_zh":"机电圆柱锁芯 E"},{"_id":"6a5a55f19af9f73f38251114","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wkładki bębenkowe mechatroniczne E","test_object_en":"Mechatronic cylinders E","methodology":"Odporność na atak przez wibrację","methodology_en":"Resistance to attack by vibration","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na atak przez wibrację","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkładki bębenkowe mechatroniczne E Odporność na atak przez wibrację Wkladki bebenkowe mechatroniczne E Odpornosc na atak przez wibracje","categories":["other"],"row_index":512,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mechatronic cylinders E Resistance to attack by vibration","search_zh":"机电圆柱锁芯 E","test_object_zh":"机电圆柱锁芯 E"},{"_id":"6a5a55f19af9f73f38251115","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wkładki bębenkowe mechatroniczne E","test_object_en":"Mechatronic cylinders E","methodology":"Odporność na atak przez zwiększone napięcie","methodology_en":"Resistance to attack by increased voltage","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na atak przez zwiększone napięcie","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkładki bębenkowe mechatroniczne E Odporność na atak przez zwiększone napięcie Wkladki bebenkowe mechatroniczne E Odpornosc na atak przez zwiekszone napiecie","categories":["other"],"row_index":513,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mechatronic cylinders E Resistance to attack by increased voltage","search_zh":"机电圆柱锁芯 E","test_object_zh":"机电圆柱锁芯 E"},{"_id":"6a5a55f19af9f73f38251116","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wkładki bębenkowe mechatroniczne E","test_object_en":"Mechatronic cylinders E","methodology":"Odporność na atak polem magnetycznym","methodology_en":"Resistance to attack by magnetic field","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na atak polem magnetycznym","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkładki bębenkowe mechatroniczne E Odporność na atak polem magnetycznym Wkladki bebenkowe mechatroniczne E Odpornosc na atak polem magnetycznym","categories":["other"],"row_index":514,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mechatronic cylinders E Resistance to attack by magnetic field","search_zh":"机电圆柱锁芯 E","test_object_zh":"机电圆柱锁芯 E"},{"_id":"6a5a55f19af9f73f38251117","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wkładki bębenkowe mechatroniczne E","test_object_en":"Mechatronic cylinders E","methodology":"Wytrzymałość klucza elektronicznego","methodology_en":"Strength of the electronic key","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość klucza elektronicznego","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkładki bębenkowe mechatroniczne E Wytrzymałość klucza elektronicznego Wkladki bebenkowe mechatroniczne E Wytrzymalosc klucza elektronicznego","categories":["electronics"],"row_index":515,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mechatronic cylinders E Strength of the electronic key","search_zh":"机电圆柱锁芯 E","test_object_zh":"机电圆柱锁芯 E"},{"_id":"6a5a55f19af9f73f38251118","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wkładki bębenkowe mechatroniczne E","test_object_en":"Mechatronic cylinders E","methodology":"Odporność klucza elektronicznego na upadek swobodny","methodology_en":"Resistance of the electronic key to free fall","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność klucza elektronicznego na upadek swobodny","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkładki bębenkowe mechatroniczne E Odporność klucza elektronicznego na upadek swobodny Wkladki bebenkowe mechatroniczne E Odpornosc klucza elektronicznego na upadek swobodny","categories":["electronics"],"row_index":516,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mechatronic cylinders E Resistance of the electronic key to free fall","search_zh":"机电圆柱锁芯 E","test_object_zh":"机电圆柱锁芯 E"},{"_id":"6a5a55f19af9f73f38251119","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wkładki bębenkowe mechatroniczne E","test_object_en":"Mechatronic cylinders E","methodology":"Odporność klucza elektronicznego na wodę","methodology_en":"Resistance of the electronic key to water","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność klucza elektronicznego na wodę","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkładki bębenkowe mechatroniczne E Odporność klucza elektronicznego na wodę Wkladki bebenkowe mechatroniczne E Odpornosc klucza elektronicznego na wode","categories":["electronics"],"row_index":517,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mechatronic cylinders E Resistance of the electronic key to water","search_zh":"机电圆柱锁芯 E","test_object_zh":"机电圆柱锁芯 E"},{"_id":"6a5a55f19af9f73f3825111a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wkładki bębenkowe E","test_object_en":"Cylinders E","methodology":"Działanie mechanizmu zabezpieczającego","methodology_en":"Operation of the safety mechanism","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Działanie mechanizmu zabezpieczającego","reference":"PN-EN 1303","norm_bases":["PN-EN 1303"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkładki bębenkowe E Działanie mechanizmu zabezpieczającego PN-EN 1303 Wkladki bebenkowe E Dzialanie mechanizmu zabezpieczajacego PN-EN 1303","categories":["other"],"row_index":518,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Cylinders E Operation of the safety mechanism PN-EN 1303","search_zh":"圆柱锁芯 E PN-EN 1303","test_object_zh":"圆柱锁芯 E"},{"_id":"6a5a55f19af9f73f3825111b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wkładki bębenkowe E","test_object_en":"Cylinders E","methodology":"Działanie w skrajnych temperaturach","methodology_en":"Operation at extreme temperatures","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Działanie w skrajnych temperaturach","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkładki bębenkowe E Działanie w skrajnych temperaturach Wkladki bebenkowe E Dzialanie w skrajnych temperaturach","categories":["other"],"row_index":519,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Cylinders E Operation at extreme temperatures","search_zh":"圆柱锁芯 E 极端温度下的工作性能","test_object_zh":"圆柱锁芯 E","methodology_zh":"极端温度下的工作性能"},{"_id":"6a5a55f19af9f73f3825111c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wkładki bębenkowe E","test_object_en":"Cylinders E","methodology":"Odporność bębenka/wkładki bębenkowej na działanie momentu obrotowego Zakres: (0 - 350) Nm","methodology_en":"Resistance of the cylinder/cylinder insert to torque Range: (0 - 350) Nm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność bębenka/wkładki bębenkowej na działanie momentu obrotowego Zakres: (0 - 350) Nm","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkładki bębenkowe E Odporność bębenka/wkładki bębenkowej na działanie momentu obrotowego Zakres: (0 - 350) Nm Wkladki bebenkowe E Odpornosc bebenka/wkladki bebenkowej na dzialanie momentu obrotowego Zakres: (0 - 350) Nm","categories":["other"],"row_index":520,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Cylinders E Resistance of the cylinder/cylinder insert to torque Range: (0 - 350) Nm","search_zh":"圆柱锁芯 E","test_object_zh":"圆柱锁芯 E"},{"_id":"6a5a55f19af9f73f3825111d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wkładki bębenkowe E","test_object_en":"Cylinders E","methodology":"Odporność na atak przez ukręcenie Zakres: (0 - 350) Nm","methodology_en":"Resistance to attack by torsion Range: (0 - 350) Nm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na atak przez ukręcenie Zakres: (0 - 350) Nm","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkładki bębenkowe E Odporność na atak przez ukręcenie Zakres: (0 - 350) Nm Wkladki bebenkowe E Odpornosc na atak przez ukrecenie Zakres: (0 - 350) Nm","categories":["other"],"row_index":521,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Cylinders E Resistance to attack by torsion Range: (0 - 350) Nm","search_zh":"圆柱锁芯 E","test_object_zh":"圆柱锁芯 E"},{"_id":"6a5a55f19af9f73f3825111e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wkładki bębenkowe E","test_object_en":"Cylinders E","methodology":"Odporność na atak przez wyrwanie bębenka/wkładki bębenkowej Zakres: (0 - 100) kN","methodology_en":"Resistance to attack by pulling out the cylinder/cylinder insert Range: (0 - 100) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na atak przez wyrwanie bębenka/wkładki bębenkowej Zakres: (0 - 100) kN","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkładki bębenkowe E Odporność na atak przez wyrwanie bębenka/wkładki bębenkowej Zakres: (0 - 100) kN Wkladki bebenkowe E Odpornosc na atak przez wyrwanie bebenka/wkladki bebenkowej Zakres: (0 - 100) kN","categories":["other"],"row_index":522,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Cylinders E Resistance to attack by pulling out the cylinder/cylinder insert Range: (0 - 100) kN","search_zh":"圆柱锁芯 E","test_object_zh":"圆柱锁芯 E"},{"_id":"6a5a55f19af9f73f3825111f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wkładki bębenkowe E","test_object_en":"Cylinders E","methodology":"Odporność na atak z użyciem przecinaka","methodology_en":"Resistance to attack using a chisel","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na atak z użyciem przecinaka","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkładki bębenkowe E Odporność na atak z użyciem przecinaka Wkladki bebenkowe E Odpornosc na atak z uzyciem przecinaka","categories":["other"],"row_index":523,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Cylinders E Resistance to attack using a chisel","search_zh":"圆柱锁芯 E","test_object_zh":"圆柱锁芯 E"},{"_id":"6a5a55f19af9f73f38251120","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wkładki bębenkowe E","test_object_en":"Cylinders E","methodology":"Odporność na atak z zastosowaniem wiercenia","methodology_en":"Resistance to attack by drilling","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na atak z zastosowaniem wiercenia","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkładki bębenkowe E Odporność na atak z zastosowaniem wiercenia Wkladki bebenkowe E Odpornosc na atak z zastosowaniem wiercenia","categories":["other"],"row_index":524,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Cylinders E Resistance to attack by drilling","search_zh":"圆柱锁芯 E","test_object_zh":"圆柱锁芯 E"},{"_id":"6a5a55f19af9f73f38251121","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wkładki bębenkowe E","test_object_en":"Cylinders E","methodology":"Odporność na korozję","methodology_en":"Corrosion resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na korozję","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkładki bębenkowe E Odporność na korozję Wkladki bebenkowe E Odpornosc na korozje","categories":["other"],"row_index":525,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Cylinders E Corrosion resistance","methodology_zh":"耐腐蚀性","search_zh":"圆柱锁芯 E 耐腐蚀性","test_object_zh":"圆柱锁芯 E"},{"_id":"6a5a55f19af9f73f38251122","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wkładki bębenkowe E","test_object_en":"Cylinders E","methodology":"Trwałość","methodology_en":"Durability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkładki bębenkowe E Trwałość Wkladki bebenkowe E Trwalosc","categories":["other"],"row_index":526,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Cylinders E Durability","methodology_zh":"耐久性","search_zh":"圆柱锁芯 E 耐久性","test_object_zh":"圆柱锁芯 E"},{"_id":"6a5a55f19af9f73f38251123","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wkładki bębenkowe E","test_object_en":"Cylinders E","methodology":"Wytrzymałość klucza","methodology_en":"Key strength","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość klucza","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkładki bębenkowe E Wytrzymałość klucza Wkladki bebenkowe E Wytrzymalosc klucza","categories":["other"],"row_index":527,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Cylinders E Key strength","search_zh":"圆柱锁芯 E 钥匙强度","test_object_zh":"圆柱锁芯 E","methodology_zh":"钥匙强度"},{"_id":"6a5a55f19af9f73f38251124","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wkładki bębenkowe E","test_object_en":"Cylinders E","methodology":"Zabezpieczenie związane z kluczem","methodology_en":"Key-related protection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zabezpieczenie związane z kluczem","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkładki bębenkowe E Zabezpieczenie związane z kluczem Wkladki bebenkowe E Zabezpieczenie zwiazane z kluczem","categories":["other"],"row_index":528,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Cylinders E Key-related protection","search_zh":"圆柱锁芯 E 与钥匙相关的防护","test_object_zh":"圆柱锁芯 E","methodology_zh":"与钥匙相关的防护"},{"_id":"6a5a55f19af9f73f38251125","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wkręty E","test_object_en":"Screws E","methodology":"Skręcanie","methodology_en":"Torsion","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skręcanie","reference":"PN-EN ISO 10666","norm_bases":["PN-EN ISO 10666"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkręty E Skręcanie PN-EN ISO 10666 Wkrety E Skrecanie PN-EN ISO 10666","categories":["other"],"row_index":529,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Screws E Torsion PN-EN ISO 10666","search_zh":"螺钉 E PN-EN ISO 10666","test_object_zh":"螺钉 E"},{"_id":"6a5a55f19af9f73f38251126","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wkręty E","test_object_en":"Screws E","methodology":"Wytrzymałość na skręcenie","methodology_en":"Torsional strength","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na skręcenie","reference":"PN-EN ISO 2702","norm_bases":["PN-EN ISO 2702"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkręty E Wytrzymałość na skręcenie PN-EN ISO 2702 Wkrety E Wytrzymalosc na skrecenie PN-EN ISO 2702","categories":["other"],"row_index":530,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Screws E Torsional strength PN-EN ISO 2702","search_zh":"螺钉 E PN-EN ISO 2702","test_object_zh":"螺钉 E"},{"_id":"6a5a55f19af9f73f38251127","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wkręty E","test_object_en":"Screws E","methodology":"Zdolność do wkręcenia","methodology_en":"Screwing-in capability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność do wkręcenia","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkręty E Zdolność do wkręcenia Wkrety E Zdolnosc do wkrecenia","categories":["other"],"row_index":531,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Screws E Screwing-in capability","search_zh":"螺钉 E","test_object_zh":"螺钉 E"},{"_id":"6a5a55f19af9f73f38251128","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wkręty E","test_object_en":"Screws E","methodology":"Zdolność do kształtowania gwintu","methodology_en":"Thread forming capability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność do kształtowania gwintu","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkręty E Zdolność do kształtowania gwintu Wkrety E Zdolnosc do ksztaltowania gwintu","categories":["other"],"row_index":532,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Screws E Thread forming capability","search_zh":"螺钉 E","test_object_zh":"螺钉 E"},{"_id":"6a5a55f19af9f73f38251129","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wkręty E","test_object_en":"Screws E","methodology":"Zdolność do wiercenia i wkręcenia","methodology_en":"Drilling and screwing-in capability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność do wiercenia i wkręcenia","reference":"PN-EN ISO 10666","norm_bases":["PN-EN ISO 10666"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkręty E Zdolność do wiercenia i wkręcenia PN-EN ISO 10666 Wkrety E Zdolnosc do wiercenia i wkrecenia PN-EN ISO 10666","categories":["other"],"row_index":533,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Screws E Drilling and screwing-in capability PN-EN ISO 10666","search_zh":"螺钉 E PN-EN ISO 10666","test_object_zh":"螺钉 E"},{"_id":"6a5a55f19af9f73f3825112a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych elastycznych E","test_object_en":"Flexible plastic products E","methodology":"Wymiary geometryczne liniowe","methodology_en":"Linear geometric dimensions","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary geometryczne liniowe","reference":"PN-EN ISO 24341 PN-EN ISO 24342 PN-EN ISO 24346","norm_bases":["PN-EN ISO 24341 PN-EN ISO 24342 PN-EN ISO 24346"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych elastycznych E Wymiary geometryczne liniowe PN-EN ISO 24341 PN-EN ISO 24342 PN-EN ISO 24346 Wyroby z tworzyw sztucznych elastycznych E Wymiary geometryczne liniowe PN-EN ISO 24341 PN-EN ISO 24342 PN-EN ISO 24346","categories":["other"],"row_index":534,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Flexible plastic products E Linear geometric dimensions PN-EN ISO 24341 PN-EN ISO 24342 PN-EN ISO 24346","methodology_zh":"几何线性尺寸","search_zh":"柔性塑料制品 E 几何线性尺寸 PN-EN ISO 24341 PN-EN ISO 24342 PN-EN ISO 24346","test_object_zh":"柔性塑料制品 E"},{"_id":"6a5a55f19af9f73f3825112b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych elastycznych E","test_object_en":"Flexible plastic products E","methodology":"Płaskość","methodology_en":"Flatness","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Płaskość","reference":"PN-EN ISO 24342 PN-EN ISO 24341","norm_bases":["PN-EN ISO 24342 PN-EN ISO 24341"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych elastycznych E Płaskość PN-EN ISO 24342 PN-EN ISO 24341 Wyroby z tworzyw sztucznych elastycznych E Plaskosc PN-EN ISO 24342 PN-EN ISO 24341","categories":["other"],"row_index":535,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Flexible plastic products E Flatness PN-EN ISO 24342 PN-EN ISO 24341","methodology_zh":"平整度","search_zh":"柔性塑料制品 E 平整度 PN-EN ISO 24342 PN-EN ISO 24341","test_object_zh":"柔性塑料制品 E"},{"_id":"6a5a55f19af9f73f3825112c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych elastycznych E","test_object_en":"Flexible plastic products E","methodology":"Prostoliniowość","methodology_en":"Straightness","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Prostoliniowość","reference":"PN-EN ISO 24341 PN-EN ISO 24342","norm_bases":["PN-EN ISO 24341 PN-EN ISO 24342"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych elastycznych E Prostoliniowość PN-EN ISO 24341 PN-EN ISO 24342 Wyroby z tworzyw sztucznych elastycznych E Prostoliniowosc PN-EN ISO 24341 PN-EN ISO 24342","categories":["other"],"row_index":536,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Flexible plastic products E Straightness PN-EN ISO 24341 PN-EN ISO 24342","search_zh":"柔性塑料制品 E PN-EN ISO 24341 PN-EN ISO 24342","test_object_zh":"柔性塑料制品 E"},{"_id":"6a5a55f19af9f73f3825112d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych elastycznych E","test_object_en":"Flexible plastic products E","methodology":"Wyznaczanie masy powierzchniowej","methodology_en":"Determination of the mass per unit area","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wyznaczanie masy powierzchniowej","reference":"PN-EN ISO 23997","norm_bases":["PN-EN ISO 23997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych elastycznych E Wyznaczanie masy powierzchniowej PN-EN ISO 23997 Wyroby z tworzyw sztucznych elastycznych E Wyznaczanie masy powierzchniowej PN-EN ISO 23997","categories":["other"],"row_index":537,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Flexible plastic products E Determination of the mass per unit area PN-EN ISO 23997","search_zh":"柔性塑料制品 E PN-EN ISO 23997","test_object_zh":"柔性塑料制品 E"},{"_id":"6a5a55f19af9f73f3825112e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamki i zaczepy E","test_object_en":"Locks and strikes E","methodology":"Działanie w skrajnych temperaturach Zakres:(-20 - +60)°C","methodology_en":"Operation at extreme temperatures Range:(-20 - +60)°C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Działanie w skrajnych temperaturach Zakres:(-20 - +60)°C","reference":"PN-EN 12209","norm_bases":["PN-EN 12209"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamki i zaczepy E Działanie w skrajnych temperaturach Zakres:(-20 - +60)°C PN-EN 12209 Zamki i zaczepy E Dzialanie w skrajnych temperaturach Zakres:(-20 - +60)°C PN-EN 12209","categories":["other"],"row_index":538,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Locks and strikes E Operation at extreme temperatures Range:(-20 - +60)°C PN-EN 12209","search_zh":"锁具与锁扣 E PN-EN 12209","test_object_zh":"锁具与锁扣 E"},{"_id":"6a5a55f19af9f73f3825112f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamki i zaczepy E","test_object_en":"Locks and strikes E","methodology":"Moment obrotowy do uruchomienia zasuwki Zakres: (0 - 350) Nm","methodology_en":"Torque to operate the deadbolt Range: (0 - 350) Nm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moment obrotowy do uruchomienia zasuwki Zakres: (0 - 350) Nm","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamki i zaczepy E Moment obrotowy do uruchomienia zasuwki Zakres: (0 - 350) Nm Zamki i zaczepy E Moment obrotowy do uruchomienia zasuwki Zakres: (0 - 350) Nm","categories":["other"],"row_index":539,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Locks and strikes E Torque to operate the deadbolt Range: (0 - 350) Nm","search_zh":"锁具与锁扣 E","test_object_zh":"锁具与锁扣 E"},{"_id":"6a5a55f19af9f73f38251130","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamki i zaczepy E","test_object_en":"Locks and strikes E","methodology":"Moment obrotowy do wycofania zapadki klamką Zakres: (0 - 350) Nm","methodology_en":"Torque to withdraw the latch bolt by the handle Range: (0 - 350) Nm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moment obrotowy do wycofania zapadki klamką Zakres: (0 - 350) Nm","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamki i zaczepy E Moment obrotowy do wycofania zapadki klamką Zakres: (0 - 350) Nm Zamki i zaczepy E Moment obrotowy do wycofania zapadki klamka Zakres: (0 - 350) Nm","categories":["other"],"row_index":540,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Locks and strikes E Torque to withdraw the latch bolt by the handle Range: (0 - 350) Nm","search_zh":"锁具与锁扣 E","test_object_zh":"锁具与锁扣 E"},{"_id":"6a5a55f19af9f73f38251131","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamki i zaczepy E","test_object_en":"Locks and strikes E","methodology":"Identyfikacja klucza","methodology_en":"Key identification","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Identyfikacja klucza","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamki i zaczepy E Identyfikacja klucza Zamki i zaczepy E Identyfikacja klucza","categories":["other"],"row_index":541,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Locks and strikes E Key identification","search_zh":"锁具与锁扣 E","test_object_zh":"锁具与锁扣 E"},{"_id":"6a5a55f19af9f73f38251132","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamki i zaczepy E","test_object_en":"Locks and strikes E","methodology":"Minimalny moment obrotowy powrotny orzecha","methodology_en":"Minimum return torque of the follower","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Minimalny moment obrotowy powrotny orzecha","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamki i zaczepy E Minimalny moment obrotowy powrotny orzecha Zamki i zaczepy E Minimalny moment obrotowy powrotny orzecha","categories":["other"],"row_index":542,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Locks and strikes E Minimum return torque of the follower","search_zh":"锁具与锁扣 E","test_object_zh":"锁具与锁扣 E"},{"_id":"6a5a55f19af9f73f38251133","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamki i zaczepy E","test_object_en":"Locks and strikes E","methodology":"Odporność na korozję","methodology_en":"Corrosion resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na korozję","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamki i zaczepy E Odporność na korozję Zamki i zaczepy E Odpornosc na korozje","categories":["other"],"row_index":543,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Locks and strikes E Corrosion resistance","methodology_zh":"耐腐蚀性","search_zh":"锁具与锁扣 E 耐腐蚀性","test_object_zh":"锁具与锁扣 E"},{"_id":"6a5a55f19af9f73f38251134","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamki i zaczepy E","test_object_en":"Locks and strikes E","methodology":"Wytrzymałość klucza","methodology_en":"Key strength","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość klucza","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamki i zaczepy E Wytrzymałość klucza Zamki i zaczepy E Wytrzymalosc klucza","categories":["other"],"row_index":544,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Locks and strikes E Key strength","search_zh":"锁具与锁扣 E 钥匙强度","test_object_zh":"锁具与锁扣 E","methodology_zh":"钥匙强度"},{"_id":"6a5a55f19af9f73f38251135","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamki i zaczepy E","test_object_en":"Locks and strikes E","methodology":"Siła powrotna zapadki Zakres: (0 - 5000) N","methodology_en":"Return force of the latch Range: (0 - 5000) N","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła powrotna zapadki Zakres: (0 - 5000) N","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamki i zaczepy E Siła powrotna zapadki Zakres: (0 - 5000) N Zamki i zaczepy E Sila powrotna zapadki Zakres: (0 - 5000) N","categories":["other"],"row_index":545,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Locks and strikes E Return force of the latch Range: (0 - 5000) N","search_zh":"锁具与锁扣 E","test_object_zh":"锁具与锁扣 E"},{"_id":"6a5a55f19af9f73f38251136","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamki i zaczepy E","test_object_en":"Locks and strikes E","methodology":"Moment obrotowy do wycofania zapadki za pomocą klucza w zamkach z dźwignią Zakres: (0 - 350) Nm","methodology_en":"Torque to withdraw the latch bolt by the key in lever locks Range: (0 - 350) Nm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moment obrotowy do wycofania zapadki za pomocą klucza w zamkach z dźwignią Zakres: (0 - 350) Nm","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamki i zaczepy E Moment obrotowy do wycofania zapadki za pomocą klucza w zamkach z dźwignią Zakres: (0 - 350) Nm Zamki i zaczepy E Moment obrotowy do wycofania zapadki za pomoca klucza w zamkach z dzwignia Zakres: (0 - 350) Nm","categories":["other"],"row_index":546,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Locks and strikes E Torque to withdraw the latch bolt by the key in lever locks Range: (0 - 350) Nm","search_zh":"锁具与锁扣 E","test_object_zh":"锁具与锁扣 E"},{"_id":"6a5a55f19af9f73f38251137","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamki i zaczepy E","test_object_en":"Locks and strikes E","methodology":"Siła zamykania ręcznego z pośrednim położeniem blokującym Zakres:(0 - 5000) N","methodology_en":"Manual closing force with intermediate locking position Range:(0 - 5000) N","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła zamykania ręcznego z pośrednim położeniem blokującym Zakres:(0 - 5000) N","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamki i zaczepy E Siła zamykania ręcznego z pośrednim położeniem blokującym Zakres:(0 - 5000) N Zamki i zaczepy E Sila zamykania recznego z posrednim polozeniem blokujacym Zakres:(0 - 5000) N","categories":["other"],"row_index":547,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Locks and strikes E Manual closing force with intermediate locking position Range:(0 - 5000) N","search_zh":"锁具与锁扣 E","test_object_zh":"锁具与锁扣 E"},{"_id":"6a5a55f19af9f73f38251138","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamki i zaczepy E","test_object_en":"Locks and strikes E","methodology":"Siła zamknięcia drzwi na zapadkę Zakres:(0 - 5000) N","methodology_en":"Force to latch the door Range:(0 - 5000) N","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła zamknięcia drzwi na zapadkę Zakres:(0 - 5000) N","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamki i zaczepy E Siła zamknięcia drzwi na zapadkę Zakres:(0 - 5000) N Zamki i zaczepy E Sila zamkniecia drzwi na zapadke Zakres:(0 - 5000) N","categories":["other"],"row_index":548,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Locks and strikes E Force to latch the door Range:(0 - 5000) N","search_zh":"锁具与锁扣 E","test_object_zh":"锁具与锁扣 E"},{"_id":"6a5a55f19af9f73f38251139","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamki i zaczepy E","test_object_en":"Locks and strikes E","methodology":"Siła zamykania ręcznego Zakres: (0 - 5000) N","methodology_en":"Manual closing force Range: (0 - 5000) N","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła zamykania ręcznego Zakres: (0 - 5000) N","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamki i zaczepy E Siła zamykania ręcznego Zakres: (0 - 5000) N Zamki i zaczepy E Sila zamykania recznego Zakres: (0 - 5000) N","categories":["other"],"row_index":549,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Locks and strikes E Manual closing force Range: (0 - 5000) N","search_zh":"锁具与锁扣 E","test_object_zh":"锁具与锁扣 E"},{"_id":"6a5a55f19af9f73f3825113a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamki i zaczepy E","test_object_en":"Locks and strikes E","methodology":"Skuteczność automatycznego zamykania zapadki","methodology_en":"Effectiveness of automatic latch closing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność automatycznego zamykania zapadki","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamki i zaczepy E Skuteczność automatycznego zamykania zapadki Zamki i zaczepy E Skutecznosc automatycznego zamykania zapadki","categories":["other"],"row_index":550,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Locks and strikes E Effectiveness of automatic latch closing","search_zh":"锁具与锁扣 E","test_object_zh":"锁具与锁扣 E"},{"_id":"6a5a55f19af9f73f3825113b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamki i zaczepy E","test_object_en":"Locks and strikes E","methodology":"Skuteczność automatycznego zamykania zasuwki","methodology_en":"Effectiveness of automatic bolt closing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność automatycznego zamykania zasuwki","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamki i zaczepy E Skuteczność automatycznego zamykania zasuwki Zamki i zaczepy E Skutecznosc automatycznego zamykania zasuwki","categories":["other"],"row_index":551,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Locks and strikes E Effectiveness of automatic bolt closing","search_zh":"锁具与锁扣 E","test_object_zh":"锁具与锁扣 E"},{"_id":"6a5a55f19af9f73f3825113c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamki i zaczepy E","test_object_en":"Locks and strikes E","methodology":"Trwałość","methodology_en":"Durability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamki i zaczepy E Trwałość Zamki i zaczepy E Trwalosc","categories":["other"],"row_index":552,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Locks and strikes E Durability","methodology_zh":"耐久性","search_zh":"锁具与锁扣 E 耐久性","test_object_zh":"锁具与锁扣 E"},{"_id":"6a5a55f19af9f73f3825113d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamki i zaczepy E","test_object_en":"Locks and strikes E","methodology":"Wytrzymałość haka na wyzębienie Zakres: (0 - 100) kN","methodology_en":"Strength of the hook against disengagement Range: (0 - 100) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość haka na wyzębienie Zakres: (0 - 100) kN","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamki i zaczepy E Wytrzymałość haka na wyzębienie Zakres: (0 - 100) kN Zamki i zaczepy E Wytrzymalosc haka na wyzebienie Zakres: (0 - 100) kN","categories":["other"],"row_index":553,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Locks and strikes E Strength of the hook against disengagement Range: (0 - 100) kN","search_zh":"锁具与锁扣 E","test_object_zh":"锁具与锁扣 E"},{"_id":"6a5a55f19af9f73f3825113e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamki i zaczepy E","test_object_en":"Locks and strikes E","methodology":"Wytrzymałość na sforsowanie urządzenia ustalającego w zamkach do drzwi przesuwnych","methodology_en":"Resistance to forcing of the locking device in locks for sliding doors","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na sforsowanie urządzenia ustalającego w zamkach do drzwi przesuwnych","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamki i zaczepy E Wytrzymałość na sforsowanie urządzenia ustalającego w zamkach do drzwi przesuwnych Zamki i zaczepy E Wytrzymalosc na sforsowanie urzadzenia ustalajacego w zamkach do drzwi przesuwnych","categories":["other"],"row_index":554,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Locks and strikes E Resistance to forcing of the locking device in locks for sliding doors","search_zh":"锁具与锁扣 E","test_object_zh":"锁具与锁扣 E"},{"_id":"6a5a55f19af9f73f3825113f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamki i zaczepy E","test_object_en":"Locks and strikes E","methodology":"Wytrzymałość mechanizmów rygli","methodology_en":"Strength of the bolt mechanisms","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość mechanizmów rygli","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamki i zaczepy E Wytrzymałość mechanizmów rygli Zamki i zaczepy E Wytrzymalosc mechanizmow rygli","categories":["other"],"row_index":555,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Locks and strikes E Strength of the bolt mechanisms","search_zh":"锁具与锁扣 E","test_object_zh":"锁具与锁扣 E"},{"_id":"6a5a55f19af9f73f38251140","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamki i zaczepy E","test_object_en":"Locks and strikes E","methodology":"Zabezpieczenie: - sposób uruchamiania kluczem i ryglowanie - odporność klamki lub gałki na działanie momentu obrotowego - odporność zasuwki na obciążenia boczne - pomiar wystawania zasuwki - odporność zasuwki na obciążenia czołowe - wytrzymałość haka na wyzębienie - wytrzymałość na sforsowanie urządzenia ustalającego w zamkach do drzwi przesuwnych - odporność na moment obrotowy zasuwki uruchamianej klamką lub gałką - silny atak kluczem na zamki z wewnętrznym elementem blokującym - odporność zaczepu chronionego skrzynką na obciążenia czołowe - odporność zaczepu chronionego skrzynką na obciążenia boczne - odporność zaczepu na wyrywanie - odporność zaczepu na działanie siły wyrywającej - zabezpieczenia związane z kluczem w zamkach z dźwignią","methodology_en":"Safety: - method of operation by key and locking - resistance of the lever handle or knob to torque - resistance of the bolt to side loads - measurement of the bolt projection - resistance of the bolt to end loads - strength of the hook against disengagement - resistance to forcing of the locking device in locks for sliding doors - resistance to torque of the bolt operated by a lever handle or knob - strong key attack on locks with an internal blocking element - resistance of the striking plate protected by a box to end loads - resistance of the striking plate protected by a box to side loads - resistance of the striking plate to tearing out - resistance of the striking plate to a pull-out force - key-related security in lever locks","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zabezpieczenie: - sposób uruchamiania kluczem i ryglowanie - odporność klamki lub gałki na działanie momentu obrotowego - odporność zasuwki na obciążenia boczne - pomiar wystawania zasuwki - odporność zasuwki na obciążenia czołowe - wytrzymałość haka na wyzębienie - wytrzymałość na sforsowanie urządzenia ustalającego w zamkach do drzwi przesuwnych - odporność na moment obrotowy zasuwki uruchamianej klamką lub gałką - silny atak kluczem na zamki z wewnętrznym elementem blokującym - odporność zaczepu chronionego skrzynką na obciążenia czołowe - odporność zaczepu chronionego skrzynką na obciążenia boczne - odporność zaczepu na wyrywanie - odporność zaczepu na działanie siły wyrywającej - zabezpieczenia związane z kluczem w zamkach z dźwignią","reference":"PN-EN 12209","norm_bases":["PN-EN 12209"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamki i zaczepy E Zabezpieczenie: - sposób uruchamiania kluczem i ryglowanie - odporność klamki lub gałki na działanie momentu obrotowego - odporność zasuwki na obciążenia boczne - pomiar wystawania zasuwki - odporność zasuwki na obciążenia czołowe - wytrzymałość haka na wyzębienie - wytrzymałość na sforsowanie urządzenia ustalającego w zamkach do drzwi przesuwnych - odporność na moment obrotowy zasuwki uruchamianej klamką lub gałką - silny atak kluczem na zamki z wewnętrznym elementem blokującym - odporność zaczepu chronionego skrzynką na obciążenia czołowe - odporność zaczepu chronionego skrzynką na obciążenia boczne - odporność zaczepu na wyrywanie - odporność zaczepu na działanie siły wyrywającej - zabezpieczenia związane z kluczem w zamkach z dźwignią PN-EN 12209 Zamki i zaczepy E Zabezpieczenie: - sposob uruchamiania kluczem i ryglowanie - odpornosc klamki lub galki na dzialanie momentu obrotowego - odpornosc zasuwki na obciazenia boczne - pomiar wystawania zasuwki - odpornosc zasuwki na obciazenia czolowe - wytrzymalosc haka na wyzebienie - wytrzymalosc na sforsowanie urzadzenia ustalajacego w zamkach do drzwi przesuwnych - odpornosc na moment obrotowy zasuwki uruchamianej klamka lub galka - silny atak kluczem na zamki z wewnetrznym elementem blokujacym - odpornosc zaczepu chronionego skrzynka na obciazenia czolowe - odpornosc zaczepu chronionego skrzynka na obciazenia boczne - odpornosc zaczepu na wyrywanie - odpornosc zaczepu na dzialanie sily wyrywajacej - zabezpieczenia zwiazane z kluczem w zamkach z dzwignia PN-EN 12209","categories":["other"],"row_index":556,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Locks and strikes E Safety: - method of operation by key and locking - resistance of the lever handle or knob to torque - resistance of the bolt to side loads - measurement of the bolt projection - resistance of the bolt to end loads - strength of the hook against disengagement - resistance to forcing of the locking device in locks for sliding doors - resistance to torque of the bolt operated by a lever handle or knob - strong key attack on locks with an internal blocking element - resistance of the striking plate protected by a box to end loads - resistance of the striking plate protected by a box to side loads - resistance of the striking plate to tearing out - resistance of the striking plate to a pull-out force - key-related security in lever locks PN-EN 12209","search_zh":"锁具与锁扣 E PN-EN 12209","test_object_zh":"锁具与锁扣 E"},{"_id":"6a5a55f19af9f73f38251141","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamki i zaczepy E","test_object_en":"Locks and strikes E","methodology":"Ochrona przed usunięciem z drzwi","methodology_en":"Protection against removal from the door","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ochrona przed usunięciem z drzwi","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamki i zaczepy E Ochrona przed usunięciem z drzwi Zamki i zaczepy E Ochrona przed usunieciem z drzwi","categories":["other"],"row_index":557,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Locks and strikes E Protection against removal from the door","search_zh":"锁具与锁扣 E","test_object_zh":"锁具与锁扣 E"},{"_id":"6a5a55f19af9f73f38251142","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamki i zaczepy elektromechaniczne E","test_object_en":"Electromechanical locks and strikes E","methodology":"Odporność zapadki na obciążenie boczne Zakres: (0 - 100) kN","methodology_en":"Resistance of the latch bolt to side load Range: (0 - 100) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność zapadki na obciążenie boczne Zakres: (0 - 100) kN","reference":"PN-EN 12209","norm_bases":["PN-EN 12209"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamki i zaczepy elektromechaniczne E Odporność zapadki na obciążenie boczne Zakres: (0 - 100) kN PN-EN 12209 Zamki i zaczepy elektromechaniczne E Odpornosc zapadki na obciazenie boczne Zakres: (0 - 100) kN PN-EN 12209","categories":["other"],"row_index":558,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electromechanical locks and strikes E Resistance of the latch bolt to side load Range: (0 - 100) kN PN-EN 12209","search_zh":"机电锁具与锁扣板 E PN-EN 12209","test_object_zh":"机电锁具与锁扣板 E"},{"_id":"6a5a55f19af9f73f38251143","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamki i zaczepy elektromechaniczne E","test_object_en":"Electromechanical locks and strikes E","methodology":"Moment obrotowy potrzebny do uruchomienia zasuwki","methodology_en":"Torque required to operate the deadbolt","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moment obrotowy potrzebny do uruchomienia zasuwki","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamki i zaczepy elektromechaniczne E Moment obrotowy potrzebny do uruchomienia zasuwki Zamki i zaczepy elektromechaniczne E Moment obrotowy potrzebny do uruchomienia zasuwki","categories":["other"],"row_index":559,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electromechanical locks and strikes E Torque required to operate the deadbolt","search_zh":"机电锁具与锁扣板 E","test_object_zh":"机电锁具与锁扣板 E"},{"_id":"6a5a55f19af9f73f38251144","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamki i zaczepy elektromechaniczne E","test_object_en":"Electromechanical locks and strikes E","methodology":"Moment obrotowy potrzebny do uruchomienia zapadki Zakres: (0 - 300) Nm","methodology_en":"Torque required to operate the latch bolt Range: (0 - 300) Nm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moment obrotowy potrzebny do uruchomienia zapadki Zakres: (0 - 300) Nm","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamki i zaczepy elektromechaniczne E Moment obrotowy potrzebny do uruchomienia zapadki Zakres: (0 - 300) Nm Zamki i zaczepy elektromechaniczne E Moment obrotowy potrzebny do uruchomienia zapadki Zakres: (0 - 300) Nm","categories":["other"],"row_index":560,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electromechanical locks and strikes E Torque required to operate the latch bolt Range: (0 - 300) Nm","search_zh":"机电锁具与锁扣板 E","test_object_zh":"机电锁具与锁扣板 E"},{"_id":"6a5a55f19af9f73f38251145","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamki i zaczepy elektromechaniczne E","test_object_en":"Electromechanical locks and strikes E","methodology":"Wytrzymałość mechanizmu zapadki i ograniczników Zakres: (0 - 100) kN","methodology_en":"Strength of the pawl mechanism and stops Range: (0 - 100) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość mechanizmu zapadki i ograniczników Zakres: (0 - 100) kN","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamki i zaczepy elektromechaniczne E Wytrzymałość mechanizmu zapadki i ograniczników Zakres: (0 - 100) kN Zamki i zaczepy elektromechaniczne E Wytrzymalosc mechanizmu zapadki i ogranicznikow Zakres: (0 - 100) kN","categories":["other"],"row_index":561,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electromechanical locks and strikes E Strength of the pawl mechanism and stops Range: (0 - 100) kN","search_zh":"机电锁具与锁扣板 E","test_object_zh":"机电锁具与锁扣板 E"},{"_id":"6a5a55f19af9f73f38251146","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamki i zaczepy elektromechaniczne E","test_object_en":"Electromechanical locks and strikes E","methodology":"Siła zamykająca","methodology_en":"Closing force","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła zamykająca","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamki i zaczepy elektromechaniczne E Siła zamykająca Zamki i zaczepy elektromechaniczne E Sila zamykajaca","categories":["other"],"row_index":562,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electromechanical locks and strikes E Closing force","search_zh":"机电锁具与锁扣板 E","test_object_zh":"机电锁具与锁扣板 E"},{"_id":"6a5a55f19af9f73f38251147","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamki i zaczepy elektromechaniczne E","test_object_en":"Electromechanical locks and strikes E","methodology":"Odporność zablokowanego orzecha na działanie momentu obrotowego Trwałość","methodology_en":"Resistance of the locked follower to torque Durability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność zablokowanego orzecha na działanie momentu obrotowego Trwałość","reference":"PN-EN 14846 PN-EN 12209","norm_bases":["PN-EN 14846 PN-EN 12209"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamki i zaczepy elektromechaniczne E Odporność zablokowanego orzecha na działanie momentu obrotowego Trwałość PN-EN 14846 PN-EN 12209 Zamki i zaczepy elektromechaniczne E Odpornosc zablokowanego orzecha na dzialanie momentu obrotowego Trwalosc PN-EN 14846 PN-EN 12209","categories":["other"],"row_index":563,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electromechanical locks and strikes E Resistance of the locked follower to torque Durability PN-EN 14846 PN-EN 12209","search_zh":"机电锁具与锁扣板 E PN-EN 14846 PN-EN 12209","test_object_zh":"机电锁具与锁扣板 E"},{"_id":"6a5a55f19af9f73f38251148","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamki i zaczepy elektromechaniczne E","test_object_en":"Electromechanical locks and strikes E","methodology":"Badanie odporności na korozję","methodology_en":"Corrosion resistance testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Badanie odporności na korozję","reference":"PN-EN 14846","norm_bases":["PN-EN 14846"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamki i zaczepy elektromechaniczne E Badanie odporności na korozję PN-EN 14846 Zamki i zaczepy elektromechaniczne E Badanie odpornosci na korozje PN-EN 14846","categories":["other"],"row_index":564,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electromechanical locks and strikes E Corrosion resistance testing PN-EN 14846","search_zh":"机电锁具与锁扣板 E PN-EN 14846","test_object_zh":"机电锁具与锁扣板 E"},{"_id":"6a5a55f19af9f73f38251149","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamknięcia awaryjne E","test_object_en":"Emergency exit devices E","methodology":"Konstrukcja","methodology_en":"Construction","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Konstrukcja","reference":"PN-EN 179","norm_bases":["PN-EN 179"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamknięcia awaryjne E Konstrukcja PN-EN 179 Zamkniecia awaryjne E Konstrukcja PN-EN 179","categories":["other"],"row_index":565,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Emergency exit devices E Construction PN-EN 179","search_zh":"应急出口装置 E PN-EN 179","test_object_zh":"应急出口装置 E"},{"_id":"6a5a55f19af9f73f3825114a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamknięcia awaryjne E","test_object_en":"Emergency exit devices E","methodology":"Działanie w skrajnych temperaturach","methodology_en":"Operation at extreme temperatures","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Działanie w skrajnych temperaturach","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamknięcia awaryjne E Działanie w skrajnych temperaturach Zamkniecia awaryjne E Dzialanie w skrajnych temperaturach","categories":["other"],"row_index":566,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Emergency exit devices E Operation at extreme temperatures","search_zh":"应急出口装置 E 极端温度下的工作性能","test_object_zh":"应急出口装置 E","methodology_zh":"极端温度下的工作性能"},{"_id":"6a5a55f19af9f73f3825114b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamknięcia awaryjne E","test_object_en":"Emergency exit devices E","methodology":"Odporność na korozję","methodology_en":"Corrosion resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na korozję","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamknięcia awaryjne E Odporność na korozję Zamkniecia awaryjne E Odpornosc na korozje","categories":["other"],"row_index":567,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Emergency exit devices E Corrosion resistance","methodology_zh":"耐腐蚀性","search_zh":"应急出口装置 E 耐腐蚀性","test_object_zh":"应急出口装置 E"},{"_id":"6a5a55f19af9f73f3825114c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamknięcia awaryjne E","test_object_en":"Emergency exit devices E","methodology":"Odporność na niewłaściwe użytkowanie","methodology_en":"Resistance to misuse","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na niewłaściwe użytkowanie","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamknięcia awaryjne E Odporność na niewłaściwe użytkowanie Zamkniecia awaryjne E Odpornosc na niewlasciwe uzytkowanie","categories":["other"],"row_index":568,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Emergency exit devices E Resistance to misuse","search_zh":"应急出口装置 E 误用的耐受性","test_object_zh":"应急出口装置 E","methodology_zh":"误用的耐受性"},{"_id":"6a5a55f19af9f73f3825114d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamknięcia awaryjne E","test_object_en":"Emergency exit devices E","methodology":"Siła ponownego zaczepienia Zakres: (0 - 5000) N","methodology_en":"Re-engagement force Range: (0 - 5000) N","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła ponownego zaczepienia Zakres: (0 - 5000) N","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamknięcia awaryjne E Siła ponownego zaczepienia Zakres: (0 - 5000) N Zamkniecia awaryjne E Sila ponownego zaczepienia Zakres: (0 - 5000) N","categories":["other"],"row_index":569,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Emergency exit devices E Re-engagement force Range: (0 - 5000) N","search_zh":"应急出口装置 E","test_object_zh":"应急出口装置 E"},{"_id":"6a5a55f19af9f73f3825114e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamknięcia awaryjne E","test_object_en":"Emergency exit devices E","methodology":"Siła zwolnienia Zakres: (0 - 5000) N","methodology_en":"Release force Range: (0 - 5000) N","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła zwolnienia Zakres: (0 - 5000) N","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamknięcia awaryjne E Siła zwolnienia Zakres: (0 - 5000) N Zamkniecia awaryjne E Sila zwolnienia Zakres: (0 - 5000) N","categories":["other"],"row_index":570,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Emergency exit devices E Release force Range: (0 - 5000) N","search_zh":"应急出口装置 E","test_object_zh":"应急出口装置 E"},{"_id":"6a5a55f19af9f73f3825114f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamknięcia awaryjne E","test_object_en":"Emergency exit devices E","methodology":"Trwałość","methodology_en":"Durability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamknięcia awaryjne E Trwałość Zamkniecia awaryjne E Trwalosc","categories":["other"],"row_index":571,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Emergency exit devices E Durability","methodology_zh":"耐久性","search_zh":"应急出口装置 E 耐久性","test_object_zh":"应急出口装置 E"},{"_id":"6a5a55f19af9f73f38251150","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamknięcia przeciwpaniczne E","test_object_en":"Panic exit devices E","methodology":"Konstrukcja","methodology_en":"Construction","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Konstrukcja","reference":"PN-EN 1125","norm_bases":["PN-EN 1125"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamknięcia przeciwpaniczne E Konstrukcja PN-EN 1125 Zamkniecia przeciwpaniczne E Konstrukcja PN-EN 1125","categories":["other"],"row_index":572,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Panic exit devices E Construction PN-EN 1125","search_zh":"逃生推杆装置 E PN-EN 1125","test_object_zh":"逃生推杆装置 E"},{"_id":"6a5a55f19af9f73f38251151","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamknięcia przeciwpaniczne E","test_object_en":"Panic exit devices E","methodology":"Odporność na korozję i działanie w skrajnych temperaturach","methodology_en":"Resistance to corrosion and operation at extreme temperatures","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na korozję i działanie w skrajnych temperaturach","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamknięcia przeciwpaniczne E Odporność na korozję i działanie w skrajnych temperaturach Zamkniecia przeciwpaniczne E Odpornosc na korozje i dzialanie w skrajnych temperaturach","categories":["other"],"row_index":573,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Panic exit devices E Resistance to corrosion and operation at extreme temperatures","search_zh":"逃生推杆装置 E","test_object_zh":"逃生推杆装置 E"},{"_id":"6a5a55f19af9f73f38251152","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamknięcia przeciwpaniczne E","test_object_en":"Panic exit devices E","methodology":"Odporność na niewłaściwe użytkowanie","methodology_en":"Resistance to misuse","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na niewłaściwe użytkowanie","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamknięcia przeciwpaniczne E Odporność na niewłaściwe użytkowanie Zamkniecia przeciwpaniczne E Odpornosc na niewlasciwe uzytkowanie","categories":["other"],"row_index":574,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Panic exit devices E Resistance to misuse","search_zh":"逃生推杆装置 E 误用的耐受性","test_object_zh":"逃生推杆装置 E","methodology_zh":"误用的耐受性"},{"_id":"6a5a55f19af9f73f38251153","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamknięcia przeciwpaniczne E","test_object_en":"Panic exit devices E","methodology":"Siła ponownego zaczepienia Zakres: (0 - 5000) N","methodology_en":"Re-engagement force Range: (0 - 5000) N","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła ponownego zaczepienia Zakres: (0 - 5000) N","reference":"PN-EN 1125","norm_bases":["PN-EN 1125"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamknięcia przeciwpaniczne E Siła ponownego zaczepienia Zakres: (0 - 5000) N PN-EN 1125 Zamkniecia przeciwpaniczne E Sila ponownego zaczepienia Zakres: (0 - 5000) N PN-EN 1125","categories":["other"],"row_index":575,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Panic exit devices E Re-engagement force Range: (0 - 5000) N PN-EN 1125","search_zh":"逃生推杆装置 E PN-EN 1125","test_object_zh":"逃生推杆装置 E"},{"_id":"6a5a55f19af9f73f38251154","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamknięcia przeciwpaniczne E","test_object_en":"Panic exit devices E","methodology":"Siła zwolnienia Zakres: (0 - 5000) N","methodology_en":"Release force Range: (0 - 5000) N","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła zwolnienia Zakres: (0 - 5000) N","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamknięcia przeciwpaniczne E Siła zwolnienia Zakres: (0 - 5000) N Zamkniecia przeciwpaniczne E Sila zwolnienia Zakres: (0 - 5000) N","categories":["other"],"row_index":576,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Panic exit devices E Release force Range: (0 - 5000) N","search_zh":"逃生推杆装置 E","test_object_zh":"逃生推杆装置 E"},{"_id":"6a5a55f19af9f73f38251155","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamknięcia przeciwpaniczne E","test_object_en":"Panic exit devices E","methodology":"Trwałość","methodology_en":"Durability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamknięcia przeciwpaniczne E Trwałość Zamkniecia przeciwpaniczne E Trwalosc","categories":["other"],"row_index":577,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Panic exit devices E Durability","methodology_zh":"耐久性","search_zh":"逃生推杆装置 E 耐久性","test_object_zh":"逃生推杆装置 E"},{"_id":"6a5a55f19af9f73f38251156","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamknięcia przeciwpaniczne E","test_object_en":"Panic exit devices E","methodology":"Zabezpieczenie Zakres: (0 - 5000) N","methodology_en":"Protection Range: (0 - 5000) N","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zabezpieczenie Zakres: (0 - 5000) N","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamknięcia przeciwpaniczne E Zabezpieczenie Zakres: (0 - 5000) N Zamkniecia przeciwpaniczne E Zabezpieczenie Zakres: (0 - 5000) N","categories":["other"],"row_index":578,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Panic exit devices E Protection Range: (0 - 5000) N","search_zh":"逃生推杆装置 E","test_object_zh":"逃生推杆装置 E"},{"_id":"6a5a55f19af9f73f38251157","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamykacze z regulacją przebiegu zamykania E","test_object_en":"Controlled door closing devices E","methodology":"Wymagania mechaniczne i trwałość","methodology_en":"Mechanical requirements and durability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymagania mechaniczne i trwałość","reference":"PN-EN 1154","norm_bases":["PN-EN 1154"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamykacze z regulacją przebiegu zamykania E Wymagania mechaniczne i trwałość PN-EN 1154 Zamykacze z regulacja przebiegu zamykania E Wymagania mechaniczne i trwalosc PN-EN 1154","categories":["other"],"row_index":579,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Controlled door closing devices E Mechanical requirements and durability PN-EN 1154","search_zh":"带关闭过程调节的闭门器 E PN-EN 1154","test_object_zh":"带关闭过程调节的闭门器 E"},{"_id":"6a5a55f19af9f73f38251158","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamykacze z regulacją przebiegu zamykania E","test_object_en":"Controlled door closing devices E","methodology":"Działanie w skrajnych temperaturach","methodology_en":"Operation at extreme temperatures","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Działanie w skrajnych temperaturach","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamykacze z regulacją przebiegu zamykania E Działanie w skrajnych temperaturach Zamykacze z regulacja przebiegu zamykania E Dzialanie w skrajnych temperaturach","categories":["other"],"row_index":580,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Controlled door closing devices E Operation at extreme temperatures","methodology_zh":"极端温度下的工作性能","search_zh":"带关闭过程调节的闭门器 E 极端温度下的工作性能","test_object_zh":"带关闭过程调节的闭门器 E"},{"_id":"6a5a55f19af9f73f38251159","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zamykacze z regulacją przebiegu zamykania E","test_object_en":"Controlled door closing devices E","methodology":"Trwałość","methodology_en":"Durability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zamykacze z regulacją przebiegu zamykania E Trwałość Zamykacze z regulacja przebiegu zamykania E Trwalosc","categories":["other"],"row_index":581,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Controlled door closing devices E Durability","methodology_zh":"耐久性","search_zh":"带关闭过程调节的闭门器 E 耐久性","test_object_zh":"带关闭过程调节的闭门器 E"},{"_id":"6a5a55f19af9f73f3825115a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zasłony zewnętrzne i żaluzje E","test_object_en":"External curtains and blinds E","methodology":"Odporność na obciążenie wiatrem +","methodology_en":"Resistance to wind load +","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenie wiatrem +","reference":"PN-EN 1932","norm_bases":["PN-EN 1932"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zasłony zewnętrzne i żaluzje E Odporność na obciążenie wiatrem + PN-EN 1932 Zaslony zewnetrzne i zaluzje E Odpornosc na obciazenie wiatrem + PN-EN 1932","categories":["other"],"row_index":582,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"External curtains and blinds E Resistance to wind load + PN-EN 1932","methodology_zh":"抗风荷载性 +","search_zh":"抗风荷载性 + PN-EN 1932"},{"_id":"6a5a55f19af9f73f3825115b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zasuwnice E","test_object_en":"Espagnolettes E","methodology":"Odporność na korozję","methodology_en":"Corrosion resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na korozję","reference":"PN-EN 13126-4","norm_bases":["PN-EN 13126-4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zasuwnice E Odporność na korozję PN-EN 13126-4 Zasuwnice E Odpornosc na korozje PN-EN 13126-4","categories":["other"],"row_index":583,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Espagnolettes E Corrosion resistance PN-EN 13126-4","methodology_zh":"耐腐蚀性","search_zh":"多点锁闭器 E 耐腐蚀性 PN-EN 13126-4","test_object_zh":"多点锁闭器 E"},{"_id":"6a5a55f19af9f73f3825115c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zasuwnice E","test_object_en":"Espagnolettes E","methodology":"Odporność urządzenia zamykającego","methodology_en":"Resistance of the locking device","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność urządzenia zamykającego","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zasuwnice E Odporność urządzenia zamykającego Zasuwnice E Odpornosc urzadzenia zamykajacego","categories":["other"],"row_index":584,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Espagnolettes E Resistance of the locking device","search_zh":"多点锁闭器 E","test_object_zh":"多点锁闭器 E"},{"_id":"6a5a55f19af9f73f3825115d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zasuwnice E","test_object_en":"Espagnolettes E","methodology":"Trwałość","methodology_en":"Durability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zasuwnice E Trwałość Zasuwnice E Trwalosc","categories":["other"],"row_index":585,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Espagnolettes E Durability","methodology_zh":"耐久性","search_zh":"多点锁闭器 E 耐久性","test_object_zh":"多点锁闭器 E"},{"_id":"6a5a55f19af9f73f3825115e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zawiasy E","test_object_en":"Hinges E","methodology":"Trwałość","methodology_en":"Durability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość","reference":"PN-EN 1935 EAD 020001-00-0405","norm_bases":["PN-EN 1935 EAD 020001-00-0405"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zawiasy E Trwałość PN-EN 1935 EAD 020001-00-0405 Zawiasy E Trwalosc PN-EN 1935 EAD 020001-00-0405","categories":["other"],"row_index":586,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Hinges E Durability PN-EN 1935 EAD 020001-00-0405","methodology_zh":"耐久性","search_zh":"合页 E 耐久性 PN-EN 1935 EAD 020001-00-0405","test_object_zh":"合页 E"},{"_id":"6a5a55f19af9f73f3825115f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zawiasy E","test_object_en":"Hinges E","methodology":"Wytrzymałość na obciążenie statyczne","methodology_en":"Resistance to static load","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na obciążenie statyczne","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zawiasy E Wytrzymałość na obciążenie statyczne Zawiasy E Wytrzymalosc na obciazenie statyczne","categories":["other"],"row_index":587,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Hinges E Resistance to static load","search_zh":"合页 E","test_object_zh":"合页 E"},{"_id":"6a5a55f19af9f73f38251160","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zawiasy E","test_object_en":"Hinges E","methodology":"Wytrzymałość na ścinanie","methodology_en":"Shear strength","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ścinanie","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zawiasy E Wytrzymałość na ścinanie Zawiasy E Wytrzymalosc na scinanie","categories":["other"],"row_index":588,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Hinges E Shear strength","methodology_zh":"抗剪强度","search_zh":"合页 E 抗剪强度","test_object_zh":"合页 E"},{"_id":"6a5a55f19af9f73f38251161","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zawiasy E","test_object_en":"Hinges E","methodology":"Początkowy cierny moment obrotowy","methodology_en":"Initial frictional torque","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Początkowy cierny moment obrotowy","reference":"PN-EN 1935","norm_bases":["PN-EN 1935"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zawiasy E Początkowy cierny moment obrotowy PN-EN 1935 Zawiasy E Poczatkowy cierny moment obrotowy PN-EN 1935","categories":["other"],"row_index":589,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Hinges E Initial frictional torque PN-EN 1935","search_zh":"合页 E PN-EN 1935","test_object_zh":"合页 E"},{"_id":"6a5a55f19af9f73f38251162","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zlewozmywaki E","test_object_en":"Sinks E","methodology":"Odporność na chemikalia i środki plamiące","methodology_en":"Resistance to chemicals and staining agents","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na chemikalia i środki plamiące","reference":"PN-EN 13310","norm_bases":["PN-EN 13310"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zlewozmywaki E Odporność na chemikalia i środki plamiące PN-EN 13310 Zlewozmywaki E Odpornosc na chemikalia i srodki plamiace PN-EN 13310","categories":["other"],"row_index":590,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sinks E Resistance to chemicals and staining agents PN-EN 13310","search_zh":"洗涤槽 E PN-EN 13310","test_object_zh":"洗涤槽 E"},{"_id":"6a5a55f19af9f73f38251163","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zlewozmywaki E","test_object_en":"Sinks E","methodology":"Odporność na ciepło w próbie na sucho","methodology_en":"Resistance to heat in the dry test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na ciepło w próbie na sucho","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zlewozmywaki E Odporność na ciepło w próbie na sucho Zlewozmywaki E Odpornosc na cieplo w probie na sucho","categories":["other"],"row_index":591,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sinks E Resistance to heat in the dry test","search_zh":"洗涤槽 E","test_object_zh":"洗涤槽 E"},{"_id":"6a5a55f19af9f73f38251164","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zlewozmywaki E","test_object_en":"Sinks E","methodology":"Odporność na obciążenia","methodology_en":"Resistance to loads","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenia","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zlewozmywaki E Odporność na obciążenia Zlewozmywaki E Odpornosc na obciazenia","categories":["other"],"row_index":592,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sinks E Resistance to loads","search_zh":"洗涤槽 E","test_object_zh":"洗涤槽 E"},{"_id":"6a5a55f19af9f73f38251165","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zlewozmywaki E","test_object_en":"Sinks E","methodology":"Odporność na zmiany temperatury","methodology_en":"Resistance to temperature changes","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zmiany temperatury","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zlewozmywaki E Odporność na zmiany temperatury Zlewozmywaki E Odpornosc na zmiany temperatury","categories":["other"],"row_index":593,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sinks E Resistance to temperature changes","search_zh":"洗涤槽 E 耐温度变化性","test_object_zh":"洗涤槽 E","methodology_zh":"耐温度变化性"},{"_id":"6a5a55f19af9f73f38251166","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zlewozmywaki E","test_object_en":"Sinks E","methodology":"Odprowadzanie wody","methodology_en":"Water drainage","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odprowadzanie wody","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zlewozmywaki E Odprowadzanie wody Zlewozmywaki E Odprowadzanie wody","categories":["water"],"row_index":594,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sinks E Water drainage","search_zh":"洗涤槽 E","test_object_zh":"洗涤槽 E"},{"_id":"6a5a55f19af9f73f38251167","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zlewozmywaki E","test_object_en":"Sinks E","methodology":"Określenie przepustowości przelewu","methodology_en":"Determination of the discharge capacity of a weir","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Określenie przepustowości przelewu","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zlewozmywaki E Określenie przepustowości przelewu Zlewozmywaki E Okreslenie przepustowosci przelewu","categories":["other"],"row_index":595,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sinks E Determination of the discharge capacity of a weir","search_zh":"洗涤槽 E","test_object_zh":"洗涤槽 E"},{"_id":"6a5a55f19af9f73f38251168","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zlewozmywaki E","test_object_en":"Sinks E","methodology":"Trwałość","methodology_en":"Durability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zlewozmywaki E Trwałość Zlewozmywaki E Trwalosc","categories":["other"],"row_index":596,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sinks E Durability","methodology_zh":"耐久性","search_zh":"洗涤槽 E 耐久性","test_object_zh":"洗涤槽 E"},{"_id":"6a5a55f19af9f73f38251169","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zlewozmywaki E","test_object_en":"Sinks E","methodology":"Wymiary geometryczne liniowe","methodology_en":"Linear geometric dimensions","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary geometryczne liniowe","reference":"PN-EN 13310 PN-EN 695","norm_bases":["PN-EN 13310 PN-EN 695"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zlewozmywaki E Wymiary geometryczne liniowe PN-EN 13310 PN-EN 695 Zlewozmywaki E Wymiary geometryczne liniowe PN-EN 13310 PN-EN 695","categories":["other"],"row_index":597,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sinks E Linear geometric dimensions PN-EN 13310 PN-EN 695","methodology_zh":"几何线性尺寸","search_zh":"洗涤槽 E 几何线性尺寸 PN-EN 13310 PN-EN 695","test_object_zh":"洗涤槽 E"},{"_id":"6a5a55f19af9f73f3825116a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Żaluzje i zasłony E","test_object_en":"Blinds and curtains E","methodology":"Odporność na uderzenie ciałem twardym","methodology_en":"Resistance to hard body impact","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie ciałem twardym","reference":"PN-EN 13330","norm_bases":["PN-EN 13330"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żaluzje i zasłony E Odporność na uderzenie ciałem twardym PN-EN 13330 Zaluzje i zaslony E Odpornosc na uderzenie cialem twardym PN-EN 13330","categories":["other"],"row_index":598,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Blinds and curtains E Resistance to hard body impact PN-EN 13330","methodology_zh":"硬物撞击抗力","search_zh":"百叶帘与窗帘 E 硬物撞击抗力 PN-EN 13330","test_object_zh":"百叶帘与窗帘 E"},{"_id":"6a5a55f19af9f73f3825116b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Żaluzje i zasłony E","test_object_en":"Blinds and curtains E","methodology":"Odporność na włamanie - próba włamania ręcznego","methodology_en":"Burglar resistance - manual burglary attempt test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na włamanie - próba włamania ręcznego","reference":"PN-EN 1630","norm_bases":["PN-EN 1630"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żaluzje i zasłony E Odporność na włamanie - próba włamania ręcznego PN-EN 1630 Zaluzje i zaslony E Odpornosc na wlamanie - proba wlamania recznego PN-EN 1630","categories":["other"],"row_index":599,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Blinds and curtains E Burglar resistance - manual burglary attempt test PN-EN 1630","search_zh":"百叶帘与窗帘 E 抗侵入性 － 手工侵入试验 PN-EN 1630","test_object_zh":"百叶帘与窗帘 E","methodology_zh":"抗侵入性 － 手工侵入试验"},{"_id":"6a5a55f19af9f73f3825116c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Żaluzje i zasłony E","test_object_en":"Blinds and curtains E","methodology":"Odporność na włamanie przy obciążeniu dynamicznym","methodology_en":"Burglar resistance under dynamic load","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na włamanie przy obciążeniu dynamicznym","reference":"PN-EN 1629","norm_bases":["PN-EN 1629"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żaluzje i zasłony E Odporność na włamanie przy obciążeniu dynamicznym PN-EN 1629 Zaluzje i zaslony E Odpornosc na wlamanie przy obciazeniu dynamicznym PN-EN 1629","categories":["other"],"row_index":600,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Blinds and curtains E Burglar resistance under dynamic load PN-EN 1629","search_zh":"百叶帘与窗帘 E 动荷载下的抗侵入性 PN-EN 1629","test_object_zh":"百叶帘与窗帘 E","methodology_zh":"动荷载下的抗侵入性"},{"_id":"6a5a55f19af9f73f3825116d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Żaluzje i zasłony E","test_object_en":"Blinds and curtains E","methodology":"Odporność na włamanie przy obciążeniu statycznym","methodology_en":"Burglar resistance under static loading","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na włamanie przy obciążeniu statycznym","reference":"PN-EN 1628","norm_bases":["PN-EN 1628"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żaluzje i zasłony E Odporność na włamanie przy obciążeniu statycznym PN-EN 1628 Zaluzje i zaslony E Odpornosc na wlamanie przy obciazeniu statycznym PN-EN 1628","categories":["other"],"row_index":601,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Blinds and curtains E Burglar resistance under static loading PN-EN 1628","search_zh":"百叶帘与窗帘 E 静荷载下的抗侵入性 PN-EN 1628","test_object_zh":"百叶帘与窗帘 E","methodology_zh":"静荷载下的抗侵入性"},{"_id":"6a5a55f19af9f73f3825116e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Żaluzje i zasłony E","test_object_en":"Blinds and curtains E","methodology":"Odporność na niewłaściwe użytkowanie","methodology_en":"Resistance to misuse","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na niewłaściwe użytkowanie","reference":"PN-EN 12194","norm_bases":["PN-EN 12194"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żaluzje i zasłony E Odporność na niewłaściwe użytkowanie PN-EN 12194 Zaluzje i zaslony E Odpornosc na niewlasciwe uzytkowanie PN-EN 12194","categories":["other"],"row_index":602,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Blinds and curtains E Resistance to misuse PN-EN 12194","search_zh":"百叶帘与窗帘 E 误用的耐受性 PN-EN 12194","test_object_zh":"百叶帘与窗帘 E","methodology_zh":"误用的耐受性"},{"_id":"6a5a55f19af9f73f3825116f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Żaluzje i zasłony E","test_object_en":"Blinds and curtains E","methodology":"Siła przy rozciąganiu","methodology_en":"Force at tension","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła przy rozciąganiu","reference":"PN-EN 13527","norm_bases":["PN-EN 13527"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żaluzje i zasłony E Siła przy rozciąganiu PN-EN 13527 Zaluzje i zaslony E Sila przy rozciaganiu PN-EN 13527","categories":["other"],"row_index":603,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Blinds and curtains E Force at tension PN-EN 13527","search_zh":"百叶帘与窗帘 E PN-EN 13527","test_object_zh":"百叶帘与窗帘 E"},{"_id":"6a5a55f19af9f73f38251170","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Żaluzje i zasłony E","test_object_en":"Blinds and curtains E","methodology":"Siła przy wciąganiu","methodology_en":"Force at pull-in","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła przy wciąganiu","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żaluzje i zasłony E Siła przy wciąganiu Zaluzje i zaslony E Sila przy wciaganiu","categories":["other"],"row_index":604,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Blinds and curtains E Force at pull-in","search_zh":"百叶帘与窗帘 E","test_object_zh":"百叶帘与窗帘 E"},{"_id":"6a5a55f19af9f73f38251171","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Żaluzje i zasłony E","test_object_en":"Blinds and curtains E","methodology":"Trwałość mechaniczna","methodology_en":"Mechanical durability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość mechaniczna","reference":"PN-EN 14201","norm_bases":["PN-EN 14201"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żaluzje i zasłony E Trwałość mechaniczna PN-EN 14201 Zaluzje i zaslony E Trwalosc mechaniczna PN-EN 14201","categories":["other"],"row_index":605,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Blinds and curtains E Mechanical durability PN-EN 14201","search_zh":"百叶帘与窗帘 E 机械耐久性 PN-EN 14201","test_object_zh":"百叶帘与窗帘 E","methodology_zh":"机械耐久性"},{"_id":"6a5a55f19af9f73f38251172","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Żaluzje i zasłony z napędem E","test_object_en":"Power operated blinds and curtains E","methodology":"Siła statyczna wywierana przez krawędź zamykającą żaluzji lub zasłony","methodology_en":"Static force exerted by the closing edge of a shutter or blind","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła statyczna wywierana przez krawędź zamykającą żaluzji lub zasłony","reference":"PN-EN 12045","norm_bases":["PN-EN 12045"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żaluzje i zasłony z napędem E Siła statyczna wywierana przez krawędź zamykającą żaluzji lub zasłony PN-EN 12045 Zaluzje i zaslony z napedem E Sila statyczna wywierana przez krawedz zamykajaca zaluzji lub zaslony PN-EN 12045","categories":["other"],"row_index":606,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Power operated blinds and curtains E Static force exerted by the closing edge of a shutter or blind PN-EN 12045"},{"_id":"6a5a55f19af9f73f38251173","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Żaluzje zwijane do okien dachowych i werandowych E","test_object_en":"Roller blinds for roof and veranda windows E","methodology":"Odporność na obciążenie śniegiem","methodology_en":"Resistance to snow load","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenie śniegiem","reference":"PN-EN 12833","norm_bases":["PN-EN 12833"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żaluzje zwijane do okien dachowych i werandowych E Odporność na obciążenie śniegiem PN-EN 12833 Zaluzje zwijane do okien dachowych i werandowych E Odpornosc na obciazenie sniegiem PN-EN 12833","categories":["construction"],"row_index":607,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Roller blinds for roof and veranda windows E Resistance to snow load PN-EN 12833"},{"_id":"6a5a55f19af9f73f38251174","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Materiały porowate","test_object_en":"Porous materials","methodology":"Oporność przepływu powietrza w zakresie Rs = (0 - 10) kPa s/m, r = (0 - 100) kPa s/m2 Metoda laboratoryjna","methodology_en":"Airflow resistance in the range Rs = (0 - 10) kPa s/m, r = (0 - 100) kPa s/m2 Laboratory method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Oporność przepływu powietrza w zakresie Rs = (0 - 10) kPa s/m, r = (0 - 100) kPa s/m2 Metoda laboratoryjna","reference":"PN-EN 29053:2011","norm_bases":["PN-EN 29053:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały porowate Oporność przepływu powietrza w zakresie Rs = (0 - 10) kPa s/m, r = (0 - 100) kPa s/m2 Metoda laboratoryjna PN-EN 29053:2011 Materialy porowate Opornosc przeplywu powietrza w zakresie Rs = (0 - 10) kPa s/m, r = (0 - 100) kPa s/m2 Metoda laboratoryjna PN-EN 29053:2011","categories":["materials"],"row_index":608,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Porous materials Airflow resistance in the range Rs = (0 - 10) kPa s/m, r = (0 - 100) kPa s/m2 Laboratory method PN-EN 29053:2011"},{"_id":"6a5a55f19af9f73f38251175","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Materiały porowate","test_object_en":"Porous materials","methodology":"Oporność przepływu powietrza w zakresie Rs = (0 - 10) kPa s/m, σ= (0 - 100) kPa s/m2 Metoda laboratoryjna","methodology_en":"Airflow resistance in the range Rs = (0 - 10) kPa s/m, σ= (0 - 100) kPa s/m2 Laboratory method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Oporność przepływu powietrza w zakresie Rs = (0 - 10) kPa s/m, σ= (0 - 100) kPa s/m2 Metoda laboratoryjna","reference":"PN-EN ISO 9053-1:2019-01","norm_bases":["PN-EN ISO 9053-1:2019-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały porowate Oporność przepływu powietrza w zakresie Rs = (0 - 10) kPa s/m, σ= (0 - 100) kPa s/m2 Metoda laboratoryjna PN-EN ISO 9053-1:2019-01 Materialy porowate Opornosc przeplywu powietrza w zakresie Rs = (0 - 10) kPa s/m, σ= (0 - 100) kPa s/m2 Metoda laboratoryjna PN-EN ISO 9053-1:2019-01","categories":["materials"],"row_index":609,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Porous materials Airflow resistance in the range Rs = (0 - 10) kPa s/m, σ= (0 - 100) kPa s/m2 Laboratory method PN-EN ISO 9053-1:2019-01"},{"_id":"6a5a55f19af9f73f38251176","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Podłogi","test_object_en":"Floors","methodology":"Tłumienie dźwięków uderzeniowych przez podłogi na stropie wzorcowym Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna","methodology_en":"Impact sound insulation of floors on a standard floor Frequency range: (100 - 5000) Hz (measurement possible for 50, 63 and 80 Hz) Laboratory method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Tłumienie dźwięków uderzeniowych przez podłogi na stropie wzorcowym Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna","reference":"PN-EN ISO 140-8:1999","norm_bases":["PN-EN ISO 140-8:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podłogi Tłumienie dźwięków uderzeniowych przez podłogi na stropie wzorcowym Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna PN-EN ISO 140-8:1999 Podlogi Tlumienie dzwiekow uderzeniowych przez podlogi na stropie wzorcowym Zakres czestotliwosci: (100 - 5000) Hz (mozliwosc pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna PN-EN ISO 140-8:1999","categories":["metrology"],"row_index":610,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Floors Impact sound insulation of floors on a standard floor Frequency range: (100 - 5000) Hz (measurement possible for 50, 63 and 80 Hz) Laboratory method PN-EN ISO 140-8:1999"},{"_id":"6a5a55f19af9f73f38251177","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Pomieszczenia w budynku (wszystkie)","test_object_en":"Rooms in a building (all)","methodology":"Poziom dźwięku (w budynku) Zakres: (22 - 137) dB in situ","methodology_en":"Sound level (in the building) Range: (22 - 137) dB in situ","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom dźwięku (w budynku) Zakres: (22 - 137) dB in situ","reference":"PN-87/B-02156 (bez p.6.3)","norm_bases":["PN-87/B-02156 (bez p.6.3)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomieszczenia w budynku (wszystkie) Poziom dźwięku (w budynku) Zakres: (22 - 137) dB in situ PN-87/B-02156 (bez p.6.3) Pomieszczenia w budynku (wszystkie) Poziom dzwieku (w budynku) Zakres: (22 - 137) dB in situ PN-87/B-02156 (bez p.6.3)","categories":["other"],"row_index":611,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooms in a building (all) Sound level (in the building) Range: (22 - 137) dB in situ PN-87/B-02156 (bez p.6.3)"},{"_id":"6a5a55f19af9f73f38251178","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stropy","test_object_en":"Floors","methodology":"Izolacyjność od dźwięków powietrznych elementów budowlanych Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna","methodology_en":"Airborne sound insulation of building elements Frequency range: (100 - 5000) Hz (measurement possible at 50, 63 and 80 Hz) Laboratory method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Izolacyjność od dźwięków powietrznych elementów budowlanych Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna","reference":"PN-EN 20140-3:1999 „N”","norm_bases":["PN-EN 20140-3:1999 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stropy Izolacyjność od dźwięków powietrznych elementów budowlanych Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna PN-EN 20140-3:1999 „N” Stropy Izolacyjnosc od dzwiekow powietrznych elementow budowlanych Zakres czestotliwosci: (100 - 5000) Hz (mozliwosc pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna PN-EN 20140-3:1999 „N”","categories":["construction"],"row_index":612,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Floors Airborne sound insulation of building elements Frequency range: (100 - 5000) Hz (measurement possible at 50, 63 and 80 Hz) Laboratory method PN-EN 20140-3:1999 „N”","methodology_zh":"建筑构件的空气声隔声性能 频率范围：(100 - 5000) Hz（可测 50、63 与 80 Hz） 实验室法","search_zh":"楼板 建筑构件的空气声隔声性能 频率范围：(100 - 5000) Hz（可测 50、63 与 80 Hz） 实验室法 PN-EN 20140-3:1999 „N”","test_object_zh":"楼板"},{"_id":"6a5a55f19af9f73f38251179","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stropy","test_object_en":"Floors","methodology":"Izolacyjność od dźwięków powietrznych pomiędzy pomieszczeniami Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) in situ","methodology_en":"Airborne sound insulation between rooms Frequency range: (100 - 5000) Hz (measurement possible for 50, 63 and 80 Hz) in situ","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Izolacyjność od dźwięków powietrznych pomiędzy pomieszczeniami Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) in situ","reference":"PN-EN ISO 140-4:2000","norm_bases":["PN-EN ISO 140-4:2000"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stropy Izolacyjność od dźwięków powietrznych pomiędzy pomieszczeniami Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) in situ PN-EN ISO 140-4:2000 Stropy Izolacyjnosc od dzwiekow powietrznych pomiedzy pomieszczeniami Zakres czestotliwosci: (100 - 5000) Hz (mozliwosc pomiaru dla 50, 63 i 80 Hz) in situ PN-EN ISO 140-4:2000","categories":["construction"],"row_index":613,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Floors Airborne sound insulation between rooms Frequency range: (100 - 5000) Hz (measurement possible for 50, 63 and 80 Hz) in situ PN-EN ISO 140-4:2000","search_zh":"楼板 PN-EN ISO 140-4:2000","test_object_zh":"楼板"},{"_id":"6a5a55f19af9f73f3825117a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stropy","test_object_en":"Floors","methodology":"Izolacyjność od dźwięków uderzeniowych stropów Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) in situ","methodology_en":"Impact sound insulation of floors Frequency range: (100 - 5000) Hz (measurement possible for 50, 63 and 80 Hz) in situ","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Izolacyjność od dźwięków uderzeniowych stropów Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) in situ","reference":"PN-EN ISO 140-7:2000","norm_bases":["PN-EN ISO 140-7:2000"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stropy Izolacyjność od dźwięków uderzeniowych stropów Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) in situ PN-EN ISO 140-7:2000 Stropy Izolacyjnosc od dzwiekow uderzeniowych stropow Zakres czestotliwosci: (100 - 5000) Hz (mozliwosc pomiaru dla 50, 63 i 80 Hz) in situ PN-EN ISO 140-7:2000","categories":["construction"],"row_index":614,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Floors Impact sound insulation of floors Frequency range: (100 - 5000) Hz (measurement possible for 50, 63 and 80 Hz) in situ PN-EN ISO 140-7:2000","search_zh":"楼板 PN-EN ISO 140-7:2000","test_object_zh":"楼板"},{"_id":"6a5a55f19af9f73f3825117b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stropy","test_object_en":"Floors","methodology":"Izolacyjność od dźwięków uderzeniowych stropów Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna","methodology_en":"Impact sound insulation of floors Frequency range: (100 - 5000) Hz (measurement possible for 50, 63 and 80 Hz) Laboratory method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Izolacyjność od dźwięków uderzeniowych stropów Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna","reference":"PN-EN ISO 140-6:1999","norm_bases":["PN-EN ISO 140-6:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stropy Izolacyjność od dźwięków uderzeniowych stropów Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna PN-EN ISO 140-6:1999 Stropy Izolacyjnosc od dzwiekow uderzeniowych stropow Zakres czestotliwosci: (100 - 5000) Hz (mozliwosc pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna PN-EN ISO 140-6:1999","categories":["construction"],"row_index":615,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Floors Impact sound insulation of floors Frequency range: (100 - 5000) Hz (measurement possible for 50, 63 and 80 Hz) Laboratory method PN-EN ISO 140-6:1999","search_zh":"楼板 PN-EN ISO 140-6:1999","test_object_zh":"楼板"},{"_id":"6a5a55f19af9f73f3825117c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Ściany wewnętrzne i ich elementy: drzwi wewnętrzne","test_object_en":"Internal walls and their components: internal doors","methodology":"Izolacyjność od dźwięków powietrznych elementów budowlanych Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna","methodology_en":"Airborne sound insulation of building elements Frequency range: (100 - 5000) Hz (measurement possible at 50, 63 and 80 Hz) Laboratory method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Izolacyjność od dźwięków powietrznych elementów budowlanych Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna","reference":"PN-EN 20140-3:1999 „N”","norm_bases":["PN-EN 20140-3:1999 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ściany wewnętrzne i ich elementy: drzwi wewnętrzne Izolacyjność od dźwięków powietrznych elementów budowlanych Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna PN-EN 20140-3:1999 „N” Sciany wewnetrzne i ich elementy: drzwi wewnetrzne Izolacyjnosc od dzwiekow powietrznych elementow budowlanych Zakres czestotliwosci: (100 - 5000) Hz (mozliwosc pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna PN-EN 20140-3:1999 „N”","categories":["construction"],"row_index":616,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Internal walls and their components: internal doors Airborne sound insulation of building elements Frequency range: (100 - 5000) Hz (measurement possible at 50, 63 and 80 Hz) Laboratory method PN-EN 20140-3:1999 „N”","methodology_zh":"建筑构件的空气声隔声性能 频率范围：(100 - 5000) Hz（可测 50、63 与 80 Hz） 实验室法","search_zh":"建筑构件的空气声隔声性能 频率范围：(100 - 5000) Hz（可测 50、63 与 80 Hz） 实验室法 PN-EN 20140-3:1999 „N”"},{"_id":"6a5a55f19af9f73f3825117d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Ściany wewnętrzne i ich elementy: drzwi wewnętrzne","test_object_en":"Internal walls and their components: internal doors","methodology":"Izolacyjność od dźwięków powietrznych pomiędzy pomieszczeniami Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) in situ","methodology_en":"Airborne sound insulation between rooms Frequency range: (100 - 5000) Hz (measurement possible for 50, 63 and 80 Hz) in situ","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Izolacyjność od dźwięków powietrznych pomiędzy pomieszczeniami Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) in situ","reference":"PN-EN ISO 140-4:2000","norm_bases":["PN-EN ISO 140-4:2000"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ściany wewnętrzne i ich elementy: drzwi wewnętrzne Izolacyjność od dźwięków powietrznych pomiędzy pomieszczeniami Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) in situ PN-EN ISO 140-4:2000 Sciany wewnetrzne i ich elementy: drzwi wewnetrzne Izolacyjnosc od dzwiekow powietrznych pomiedzy pomieszczeniami Zakres czestotliwosci: (100 - 5000) Hz (mozliwosc pomiaru dla 50, 63 i 80 Hz) in situ PN-EN ISO 140-4:2000","categories":["construction"],"row_index":617,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Internal walls and their components: internal doors Airborne sound insulation between rooms Frequency range: (100 - 5000) Hz (measurement possible for 50, 63 and 80 Hz) in situ PN-EN ISO 140-4:2000"},{"_id":"6a5a55f19af9f73f3825117e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Ściany zewnętrzne i ich elementy: bramy (przemysłowe, garażowe), drzwi zewnętrzne, okna","test_object_en":"External walls and their components: gates (industrial, garage), external doors, windows","methodology":"Izolacyjność od dźwięków powietrznych elementów budowlanych Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna","methodology_en":"Airborne sound insulation of building elements Frequency range: (100 - 5000) Hz (measurement possible at 50, 63 and 80 Hz) Laboratory method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Izolacyjność od dźwięków powietrznych elementów budowlanych Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna","reference":"PN-EN 20140-3:1999 „N”","norm_bases":["PN-EN 20140-3:1999 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ściany zewnętrzne i ich elementy: bramy (przemysłowe, garażowe), drzwi zewnętrzne, okna Izolacyjność od dźwięków powietrznych elementów budowlanych Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna PN-EN 20140-3:1999 „N” Sciany zewnetrzne i ich elementy: bramy (przemyslowe, garazowe), drzwi zewnetrzne, okna Izolacyjnosc od dzwiekow powietrznych elementow budowlanych Zakres czestotliwosci: (100 - 5000) Hz (mozliwosc pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna PN-EN 20140-3:1999 „N”","categories":["construction"],"row_index":618,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"External walls and their components: gates (industrial, garage), external doors, windows Airborne sound insulation of building elements Frequency range: (100 - 5000) Hz (measurement possible at 50, 63 and 80 Hz) Laboratory method PN-EN 20140-3:1999 „N”","methodology_zh":"建筑构件的空气声隔声性能 频率范围：(100 - 5000) Hz（可测 50、63 与 80 Hz） 实验室法","search_zh":"建筑构件的空气声隔声性能 频率范围：(100 - 5000) Hz（可测 50、63 与 80 Hz） 实验室法 PN-EN 20140-3:1999 „N”"},{"_id":"6a5a55f19af9f73f3825117f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Ściany zewnętrzne i ich elementy: bramy (przemysłowe, garażowe), drzwi zewnętrzne, okna","test_object_en":"External walls and their components: gates (industrial, garage), external doors, windows","methodology":"Izolacyjność od dźwięków powietrznych przegród zewnętrznych i ich elementów Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) in situ","methodology_en":"Airborne sound insulation of external building elements and their components Frequency range: (100 - 5000) Hz (measurement possible for 50, 63 and 80 Hz) in situ","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Izolacyjność od dźwięków powietrznych przegród zewnętrznych i ich elementów Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) in situ","reference":"PN-EN ISO 140-5:1999","norm_bases":["PN-EN ISO 140-5:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ściany zewnętrzne i ich elementy: bramy (przemysłowe, garażowe), drzwi zewnętrzne, okna Izolacyjność od dźwięków powietrznych przegród zewnętrznych i ich elementów Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) in situ PN-EN ISO 140-5:1999 Sciany zewnetrzne i ich elementy: bramy (przemyslowe, garazowe), drzwi zewnetrzne, okna Izolacyjnosc od dzwiekow powietrznych przegrod zewnetrznych i ich elementow Zakres czestotliwosci: (100 - 5000) Hz (mozliwosc pomiaru dla 50, 63 i 80 Hz) in situ PN-EN ISO 140-5:1999","categories":["construction"],"row_index":619,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"External walls and their components: gates (industrial, garage), external doors, windows Airborne sound insulation of external building elements and their components Frequency range: (100 - 5000) Hz (measurement possible for 50, 63 and 80 Hz) in situ PN-EN ISO 140-5:1999"},{"_id":"6a5a55f19af9f73f38251180","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Szyby","test_object_en":"Glass panes","methodology":"Izolacyjność od dźwięków powietrznych elementów budowlanych Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna","methodology_en":"Airborne sound insulation of building elements Frequency range: (100 - 5000) Hz (measurement possible at 50, 63 and 80 Hz) Laboratory method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Izolacyjność od dźwięków powietrznych elementów budowlanych Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna","reference":"PN-EN 20140-3:1999 „N”","norm_bases":["PN-EN 20140-3:1999 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Szyby Izolacyjność od dźwięków powietrznych elementów budowlanych Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna PN-EN 20140-3:1999 „N” Szyby Izolacyjnosc od dzwiekow powietrznych elementow budowlanych Zakres czestotliwosci: (100 - 5000) Hz (mozliwosc pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna PN-EN 20140-3:1999 „N”","categories":["construction"],"row_index":620,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Glass panes Airborne sound insulation of building elements Frequency range: (100 - 5000) Hz (measurement possible at 50, 63 and 80 Hz) Laboratory method PN-EN 20140-3:1999 „N”","methodology_zh":"建筑构件的空气声隔声性能 频率范围：(100 - 5000) Hz（可测 50、63 与 80 Hz） 实验室法","search_zh":"玻璃 建筑构件的空气声隔声性能 频率范围：(100 - 5000) Hz（可测 50、63 与 80 Hz） 实验室法 PN-EN 20140-3:1999 „N”","test_object_zh":"玻璃"},{"_id":"6a5a55f19af9f73f38251181","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Bramy","test_object_en":"Gates","methodology":"Współczynnik przenikania ciepła. Obliczeniowa metoda badawcza. Zakres: ≥ 0,2 W/(m2K)","methodology_en":"Thermal transmittance. Calculation test method. Range: ≥ 0,2 W/(m2K)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Współczynnik przenikania ciepła. Obliczeniowa metoda badawcza. Zakres: ≥ 0,2 W/(m2K)","reference":"PN-EN 12428:2013-06 „N”","norm_bases":["PN-EN 12428:2013-06 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bramy Współczynnik przenikania ciepła. Obliczeniowa metoda badawcza. Zakres: ≥ 0,2 W/(m2K) PN-EN 12428:2013-06 „N” Bramy Wspolczynnik przenikania ciepla. Obliczeniowa metoda badawcza. Zakres: ≥ 0,2 W/(m2K) PN-EN 12428:2013-06 „N”","categories":["other"],"row_index":621,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gates Thermal transmittance. Calculation test method. Range: ≥ 0,2 W/(m2K) PN-EN 12428:2013-06 „N”","search_zh":"大门 PN-EN 12428:2013-06 „N”","test_object_zh":"大门"},{"_id":"6a5a55f19af9f73f38251182","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna lub świetliki wystające poza lico przegród","test_object_en":"Windows or rooflights projecting beyond the face of the building envelope","methodology":"Współczynnik przenikania ciepła Zakres: (0,2 - 3,0) W/(m2 K)","methodology_en":"Thermal transmittance Range: (0,2 - 3,0) W/(m2 K)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Współczynnik przenikania ciepła Zakres: (0,2 - 3,0) W/(m2 K)","reference":"PN-EN ISO 12567-2:2006 „N” PN-EN ISO 8990:1998 PN-EN 1873:2009 p. 5.9 „N”","norm_bases":["PN-EN ISO 12567-2:2006 „N” PN-EN ISO 8990:1998 PN-EN 1873:2009 p. 5.9 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna lub świetliki wystające poza lico przegród Współczynnik przenikania ciepła Zakres: (0,2 - 3,0) W/(m2 K) PN-EN ISO 12567-2:2006 „N” PN-EN ISO 8990:1998 PN-EN 1873:2009 p. 5.9 „N” Okna lub swietliki wystajace poza lico przegrod Wspolczynnik przenikania ciepla Zakres: (0,2 - 3,0) W/(m2 K) PN-EN ISO 12567-2:2006 „N” PN-EN ISO 8990:1998 PN-EN 1873:2009 p. 5.9 „N”","categories":["other"],"row_index":622,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows or rooflights projecting beyond the face of the building envelope Thermal transmittance Range: (0,2 - 3,0) W/(m2 K) PN-EN ISO 12567-2:2006 „N” PN-EN ISO 8990:1998 PN-EN 1873:2009 p. 5.9 „N”"},{"_id":"6a5a55f19af9f73f38251183","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okna z nawiewnikami - o różnym nachyleniu, nawiewniki powietrza zewnętrznego do pomieszczeń","test_object_en":"Windows with air inlets - at various inclinations, external air inlets for rooms","methodology":"Charakterystyki przepływowe Zakres: strumień powietrza (0,48 - 251) m3/h, różnica ciśnień do 400 Pa","methodology_en":"Flow characteristics Range: air flow rate (0,48 - 251) m3/h, pressure difference up to 400 Pa","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Charakterystyki przepływowe Zakres: strumień powietrza (0,48 - 251) m3/h, różnica ciśnień do 400 Pa","reference":"PN-EN 13141-1:2019-03","norm_bases":["PN-EN 13141-1:2019-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna z nawiewnikami - o różnym nachyleniu, nawiewniki powietrza zewnętrznego do pomieszczeń Charakterystyki przepływowe Zakres: strumień powietrza (0,48 - 251) m3/h, różnica ciśnień do 400 Pa PN-EN 13141-1:2019-03 Okna z nawiewnikami - o roznym nachyleniu, nawiewniki powietrza zewnetrznego do pomieszczen Charakterystyki przeplywowe Zakres: strumien powietrza (0,48 - 251) m3/h, roznica cisnien do 400 Pa PN-EN 13141-1:2019-03","categories":["other"],"row_index":623,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows with air inlets - at various inclinations, external air inlets for rooms Flow characteristics Range: air flow rate (0,48 - 251) m3/h, pressure difference up to 400 Pa PN-EN 13141-1:2019-03"},{"_id":"6a5a55f19af9f73f38251184","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kontenerowe i/lub montowane na miejscu budowy oczyszczalnie ścieków","test_object_en":"Containerised and/or site-assembled wastewater treatment plants","methodology":"Skuteczność oczyszczania - ścieki Biochemiczne zapotrzebowanie tlenu BZT 5 Zakres: (1 - 6000) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Treatment efficiency - wastewater Biochemical oxygen demand BOD 5 Range: (1 - 6000) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność oczyszczania - ścieki Biochemiczne zapotrzebowanie tlenu BZT 5 Zakres: (1 - 6000) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN 12566-3:2016-10 „N” PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN 12566-3:2016-10 „N” PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kontenerowe i/lub montowane na miejscu budowy oczyszczalnie ścieków Skuteczność oczyszczania - ścieki Biochemiczne zapotrzebowanie tlenu BZT 5 Zakres: (1 - 6000) mg/l O 2 Metoda elektrochemiczna PN-EN 12566-3:2016-10 „N” PN-EN ISO 5815-1:2019-12 Kontenerowe i/lub montowane na miejscu budowy oczyszczalnie sciekow Skutecznosc oczyszczania - scieki Biochemiczne zapotrzebowanie tlenu BZT 5 Zakres: (1 - 6000) mg/l O 2 Metoda elektrochemiczna PN-EN 12566-3:2016-10 „N” PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":624,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Containerised and/or site-assembled wastewater treatment plants Treatment efficiency - wastewater Biochemical oxygen demand BOD 5 Range: (1 - 6000) mg/l O 2 Electrochemical method PN-EN 12566-3:2016-10 „N” PN-EN ISO 5815-1:2019-12"},{"_id":"6a5a55f19af9f73f38251185","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Pasma świetlne","test_object_en":"Luminous bands","methodology":"Współczynnik przenikania ciepła Obliczeniowa metoda badawcza Zakres: ≥ 0,2 W/(m2K)","methodology_en":"Thermal transmittance Calculation test method Range: ≥ 0,2 W/(m2K)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Współczynnik przenikania ciepła Obliczeniowa metoda badawcza Zakres: ≥ 0,2 W/(m2K)","reference":"PN-EN 14963:2006 „N”","norm_bases":["PN-EN 14963:2006 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pasma świetlne Współczynnik przenikania ciepła Obliczeniowa metoda badawcza Zakres: ≥ 0,2 W/(m2K) PN-EN 14963:2006 „N” Pasma swietlne Wspolczynnik przenikania ciepla Obliczeniowa metoda badawcza Zakres: ≥ 0,2 W/(m2K) PN-EN 14963:2006 „N”","categories":["other"],"row_index":625,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Luminous bands Thermal transmittance Calculation test method Range: ≥ 0,2 W/(m2K) PN-EN 14963:2006 „N”"},{"_id":"6a5a55f19af9f73f38251186","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Powietrze w pomieszczeniach: budynków mieszkalnych, użyteczności publicznej, zakładów pracy","test_object_en":"Air in rooms of: residential buildings, public utility buildings, workplaces","methodology":"Pobieranie próbek do badań in situ","methodology_en":"Sampling for in situ testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań in situ","reference":"ISO 16000-6:2021 ISO 16000-3:2022","norm_bases":["ISO 16000-6:2021 ISO 16000-3:2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powietrze w pomieszczeniach: budynków mieszkalnych, użyteczności publicznej, zakładów pracy Pobieranie próbek do badań in situ ISO 16000-6:2021 ISO 16000-3:2022 Powietrze w pomieszczeniach: budynkow mieszkalnych, uzytecznosci publicznej, zakladow pracy Pobieranie probek do badan in situ ISO 16000-6:2021 ISO 16000-3:2022","categories":["environment"],"row_index":626,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Air in rooms of: residential buildings, public utility buildings, workplaces Sampling for in situ testing ISO 16000-6:2021 ISO 16000-3:2022"},{"_id":"6a5a55f19af9f73f38251187","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby budowlane pochodzenia chemicznego","test_object_en":"Construction products of chemical origin","methodology":"Emisja amoniaku Zakres: (0,03 - 6) mg/m3 Metoda spektrofotometryczna","methodology_en":"Emission of ammonia Range: (0,03 - 6) mg/m3 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja amoniaku Zakres: (0,03 - 6) mg/m3 Metoda spektrofotometryczna","reference":"PN-EN 16516+A1:2020-12 PN ISO 7150-1:2002","norm_bases":["PN-EN 16516+A1:2020-12 PN ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby budowlane pochodzenia chemicznego Emisja amoniaku Zakres: (0,03 - 6) mg/m3 Metoda spektrofotometryczna PN-EN 16516+A1:2020-12 PN ISO 7150-1:2002 Wyroby budowlane pochodzenia chemicznego Emisja amoniaku Zakres: (0,03 - 6) mg/m3 Metoda spektrofotometryczna PN-EN 16516+A1:2020-12 PN ISO 7150-1:2002","categories":["environment","construction"],"row_index":627,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Construction products of chemical origin Emission of ammonia Range: (0,03 - 6) mg/m3 Spectrophotometric method PN-EN 16516+A1:2020-12 PN ISO 7150-1:2002"},{"_id":"6a5a55f19af9f73f38251188","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby do izolacji cieplnej, wyposażenia budynków i instalacji przemysłowych (ekstrakty wodne)","test_object_en":"Thermal insulation products for building equipment and industrial installations (aqueous extracts)","methodology":"Stężenie chlorków Zakres: (0,01 - 10) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Zawartość chlorków (z obliczeń)","methodology_en":"Chloride concentration Range: (0,01 - 10) mg/l Ion chromatography with conductometric detection (IC-CD) Chloride content (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (0,01 - 10) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Zawartość chlorków (z obliczeń)","reference":"PN-EN 13468:2004 „N” PN-EN ISO 12624:2023-02 PN-EN ISO 10304-1:2009 PN-EN ISO 10304-1:2009/AC:2012","norm_bases":["PN-EN 13468:2004 „N” PN-EN ISO 12624:2023-02 PN-EN ISO 10304-1:2009 PN-EN ISO 10304-1:2009/AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby do izolacji cieplnej, wyposażenia budynków i instalacji przemysłowych (ekstrakty wodne) Stężenie chlorków Zakres: (0,01 - 10) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Zawartość chlorków (z obliczeń) PN-EN 13468:2004 „N” PN-EN ISO 12624:2023-02 PN-EN ISO 10304-1:2009 PN-EN ISO 10304-1:2009/AC:2012 Wyroby do izolacji cieplnej, wyposazenia budynkow i instalacji przemyslowych (ekstrakty wodne) Stezenie chlorkow Zakres: (0,01 - 10) mg/l Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Zawartosc chlorkow (z obliczen) PN-EN 13468:2004 „N” PN-EN ISO 12624:2023-02 PN-EN ISO 10304-1:2009 PN-EN ISO 10304-1:2009/AC:2012","categories":["construction"],"row_index":628,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation products for building equipment and industrial installations (aqueous extracts) Chloride concentration Range: (0,01 - 10) mg/l Ion chromatography with conductometric detection (IC-CD) Chloride content (calculated) PN-EN 13468:2004 „N” PN-EN ISO 12624:2023-02 PN-EN ISO 10304-1:2009 PN-EN ISO 10304-1:2009/AC:2012","search_zh":"建筑物配套与工业装置绝热用制品（水浸出液） PN-EN 13468:2004 „N” PN-EN ISO 12624:2023-02 PN-EN ISO 10304-1:2009 PN-EN ISO 10304-1:2009/AC:2012","test_object_zh":"建筑物配套与工业装置绝热用制品（水浸出液）"},{"_id":"6a5a55f19af9f73f38251189","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby do izolacji cieplnej, wyposażenia budynków i instalacji przemysłowych (ekstrakty wodne)","test_object_en":"Thermal insulation products for building equipment and industrial installations (aqueous extracts)","methodology":"Stężenie fluorków Zakres: (0,01 - 10) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Zawartość fluorków (z obliczeń)","methodology_en":"Fluoride concentration Range: (0,01 - 10) mg/l Ion chromatography with conductometric detection (IC-CD) Fluoride content (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fluorków Zakres: (0,01 - 10) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Zawartość fluorków (z obliczeń)","reference":"PN-EN 13468:2004 „N” PN-EN ISO 12624:2023-02 PN-EN ISO 10304-1:2009 PN-EN ISO 10304-1:2009/AC:2012","norm_bases":["PN-EN 13468:2004 „N” PN-EN ISO 12624:2023-02 PN-EN ISO 10304-1:2009 PN-EN ISO 10304-1:2009/AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby do izolacji cieplnej, wyposażenia budynków i instalacji przemysłowych (ekstrakty wodne) Stężenie fluorków Zakres: (0,01 - 10) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Zawartość fluorków (z obliczeń) PN-EN 13468:2004 „N” PN-EN ISO 12624:2023-02 PN-EN ISO 10304-1:2009 PN-EN ISO 10304-1:2009/AC:2012 Wyroby do izolacji cieplnej, wyposazenia budynkow i instalacji przemyslowych (ekstrakty wodne) Stezenie fluorkow Zakres: (0,01 - 10) mg/l Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Zawartosc fluorkow (z obliczen) PN-EN 13468:2004 „N” PN-EN ISO 12624:2023-02 PN-EN ISO 10304-1:2009 PN-EN ISO 10304-1:2009/AC:2012","categories":["construction"],"row_index":629,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation products for building equipment and industrial installations (aqueous extracts) Fluoride concentration Range: (0,01 - 10) mg/l Ion chromatography with conductometric detection (IC-CD) Fluoride content (calculated) PN-EN 13468:2004 „N” PN-EN ISO 12624:2023-02 PN-EN ISO 10304-1:2009 PN-EN ISO 10304-1:2009/AC:2012","search_zh":"建筑物配套与工业装置绝热用制品（水浸出液） PN-EN 13468:2004 „N” PN-EN ISO 12624:2023-02 PN-EN ISO 10304-1:2009 PN-EN ISO 10304-1:2009/AC:2012","test_object_zh":"建筑物配套与工业装置绝热用制品（水浸出液）"},{"_id":"6a5a55f19af9f73f3825118a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby do izolacji cieplnej, wyposażenia budynków i instalacji przemysłowych (ekstrakty wodne)","test_object_en":"Thermal insulation products for building equipment and industrial installations (aqueous extracts)","methodology":"Stężenie krzemianów Zakres: (0,03 - 5) mg/l Metoda spektrofotometryczna Zawartość krzemianów (z obliczeń)","methodology_en":"Silicate concentration Range: (0,03 - 5) mg/l Spectrophotometric method Silicate content (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie krzemianów Zakres: (0,03 - 5) mg/l Metoda spektrofotometryczna Zawartość krzemianów (z obliczeń)","reference":"PN-EN 13468:2004 „N” PN-EN ISO 12624:2023-02 ISO 10136-1:1993","norm_bases":["PN-EN 13468:2004 „N” PN-EN ISO 12624:2023-02 ISO 10136-1:1993"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby do izolacji cieplnej, wyposażenia budynków i instalacji przemysłowych (ekstrakty wodne) Stężenie krzemianów Zakres: (0,03 - 5) mg/l Metoda spektrofotometryczna Zawartość krzemianów (z obliczeń) PN-EN 13468:2004 „N” PN-EN ISO 12624:2023-02 ISO 10136-1:1993 Wyroby do izolacji cieplnej, wyposazenia budynkow i instalacji przemyslowych (ekstrakty wodne) Stezenie krzemianow Zakres: (0,03 - 5) mg/l Metoda spektrofotometryczna Zawartosc krzemianow (z obliczen) PN-EN 13468:2004 „N” PN-EN ISO 12624:2023-02 ISO 10136-1:1993","categories":["construction"],"row_index":630,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation products for building equipment and industrial installations (aqueous extracts) Silicate concentration Range: (0,03 - 5) mg/l Spectrophotometric method Silicate content (calculated) PN-EN 13468:2004 „N” PN-EN ISO 12624:2023-02 ISO 10136-1:1993","search_zh":"建筑物配套与工业装置绝热用制品（水浸出液） PN-EN 13468:2004 „N” PN-EN ISO 12624:2023-02 ISO 10136-1:1993","test_object_zh":"建筑物配套与工业装置绝热用制品（水浸出液）"},{"_id":"6a5a55f19af9f73f3825118b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby do izolacji cieplnej, wyposażenia budynków i instalacji przemysłowych (ekstrakty wodne)","test_object_en":"Thermal insulation products for building equipment and industrial installations (aqueous extracts)","methodology":"pH Zakres: 2,0 - 12,0 Metoda potencjometryczna","methodology_en":"pH Range: 2,0 - 12,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 2,0 - 12,0 Metoda potencjometryczna","reference":"PN-EN 13468:2004 „N” PN-EN ISO 12624:2023-02 PN-EN ISO 10523:2012","norm_bases":["PN-EN 13468:2004 „N” PN-EN ISO 12624:2023-02 PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby do izolacji cieplnej, wyposażenia budynków i instalacji przemysłowych (ekstrakty wodne) pH Zakres: 2,0 - 12,0 Metoda potencjometryczna PN-EN 13468:2004 „N” PN-EN ISO 12624:2023-02 PN-EN ISO 10523:2012 Wyroby do izolacji cieplnej, wyposazenia budynkow i instalacji przemyslowych (ekstrakty wodne) pH Zakres: 2,0 - 12,0 Metoda potencjometryczna PN-EN 13468:2004 „N” PN-EN ISO 12624:2023-02 PN-EN ISO 10523:2012","categories":["construction"],"row_index":631,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation products for building equipment and industrial installations (aqueous extracts) pH Range: 2,0 - 12,0 Potentiometric method PN-EN 13468:2004 „N” PN-EN ISO 12624:2023-02 PN-EN ISO 10523:2012","search_zh":"建筑物配套与工业装置绝热用制品（水浸出液） PN-EN 13468:2004 „N” PN-EN ISO 12624:2023-02 PN-EN ISO 10523:2012","test_object_zh":"建筑物配套与工业装置绝热用制品（水浸出液）"},{"_id":"6a5a55f19af9f73f3825118c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Materiały i wyroby do izolacji cieplnej, w tym:  wyroby z ekspandowanego korka (IC)  wyroby z ekspandowanego perlitu (EP)  wyroby z pianki fenolowej (PF)  wyroby z polistyrenu ekstrudowanego (XPS)  wyroby z wełny drzewnej (WW)  wyroby z wełny mineralnej (MW)  wyroby z włókien drzewnych (WF)  wyroby ze styropianu (EPS)  wyroby ze szkła piankowego (CG)  wyroby ze sztywnej pianki poliuretanowej (PUR) i pianki poliizocyjanurowej (PIR)","test_object_en":"Thermal insulation materials and products, including:  expanded cork products (IC)  expanded perlite products (EP)  phenolic foam products (PF)  extruded polystyrene products (XPS)  wood wool products (WW)  mineral wool products (MW)  wood fibre products (WF)  expanded polystyrene products (EPS)  cellular glass products (CG)  rigid polyurethane foam (PUR) and polyisocyanurate foam (PIR) products","methodology":"Nasiąkliwość wodą przy długotrwałym zanurzeniu w kg/m2 - zakres: bez ograniczeń, w % (m3/m3) Zakres: < 100","methodology_en":"Water absorption by long-term immersion in kg/m2 - range: unlimited, in % (m3/m3) Range: < 100","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nasiąkliwość wodą przy długotrwałym zanurzeniu w kg/m2 - zakres: bez ograniczeń, w % (m3/m3) Zakres: < 100","reference":"PN-EN 12087:2013-07 metoda 1A | PN-EN ISO 16535:2019-08 metoda 1A","norm_bases":["PN-EN 12087:2013-07 metoda 1A","PN-EN ISO 16535:2019-08 metoda 1A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały i wyroby do izolacji cieplnej, w tym:  wyroby z ekspandowanego korka (IC)  wyroby z ekspandowanego perlitu (EP)  wyroby z pianki fenolowej (PF)  wyroby z polistyrenu ekstrudowanego (XPS)  wyroby z wełny drzewnej (WW)  wyroby z wełny mineralnej (MW)  wyroby z włókien drzewnych (WF)  wyroby ze styropianu (EPS)  wyroby ze szkła piankowego (CG)  wyroby ze sztywnej pianki poliuretanowej (PUR) i pianki poliizocyjanurowej (PIR) Nasiąkliwość wodą przy długotrwałym zanurzeniu w kg/m2 - zakres: bez ograniczeń, w % (m3/m3) Zakres: < 100 PN-EN 12087:2013-07 metoda 1A | PN-EN ISO 16535:2019-08 metoda 1A Materialy i wyroby do izolacji cieplnej, w tym:  wyroby z ekspandowanego korka (IC)  wyroby z ekspandowanego perlitu (EP)  wyroby z pianki fenolowej (PF)  wyroby z polistyrenu ekstrudowanego (XPS)  wyroby z welny drzewnej (WW)  wyroby z welny mineralnej (MW)  wyroby z wlokien drzewnych (WF)  wyroby ze styropianu (EPS)  wyroby ze szkla piankowego (CG)  wyroby ze sztywnej pianki poliuretanowej (PUR) i pianki poliizocyjanurowej (PIR) Nasiakliwosc woda przy dlugotrwalym zanurzeniu w kg/m2 - zakres: bez ograniczen, w % (m3/m3) Zakres: < 100 PN-EN 12087:2013-07 metoda 1A | PN-EN ISO 16535:2019-08 metoda 1A","categories":["materials","construction"],"row_index":632,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation materials and products, including:  expanded cork products (IC)  expanded perlite products (EP)  phenolic foam products (PF)  extruded polystyrene products (XPS)  wood wool products (WW)  mineral wool products (MW)  wood fibre products (WF)  expanded polystyrene products (EPS)  cellular glass products (CG)  rigid polyurethane foam (PUR) and polyisocyanurate foam (PIR) products Water absorption by long-term immersion in kg/m2 - range: unlimited, in % (m3/m3) Range: < 100 PN-EN 12087:2013-07 metoda 1A | PN-EN ISO 16535:2019-08 metoda 1A","search_zh":"绝热材料与制品，其中包括：膨胀软木制品（IC）、膨胀珍珠岩制品（EP）、酚醛泡沫制品（PF）、挤塑聚苯乙烯制品（XPS）、木丝板制品（WW）、矿物棉制品（MW）、木纤维制品（WF）、模塑聚苯乙烯制品（EPS）、泡沫玻璃制品（CG）、硬质聚氨酯泡沫（PUR）与聚异氰脲酸酯泡沫（PIR）制品 PN-EN 12087:2013-07 metoda 1A | PN-EN ISO 16535:2019-08 metoda 1A","test_object_zh":"绝热材料与制品，其中包括：膨胀软木制品（IC）、膨胀珍珠岩制品（EP）、酚醛泡沫制品（PF）、挤塑聚苯乙烯制品（XPS）、木丝板制品（WW）、矿物棉制品（MW）、木纤维制品（WF）、模塑聚苯乙烯制品（EPS）、泡沫玻璃制品（CG）、硬质聚氨酯泡沫（PUR）与聚异氰脲酸酯泡沫（PIR）制品"},{"_id":"6a5a55f19af9f73f3825118d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Materiały i wyroby do izolacji cieplnej, w tym:  wyroby z ekspandowanego korka (IC)  wyroby z ekspandowanego perlitu (EP)  wyroby z pianki fenolowej (PF)  wyroby z polistyrenu ekstrudowanego (XPS)  wyroby z wełny drzewnej (WW)  wyroby z wełny mineralnej (MW)  wyroby z włókien drzewnych (WF)  wyroby ze styropianu (EPS)  wyroby ze szkła piankowego (CG)  wyroby ze sztywnej pianki poliuretanowej (PUR) i pianki poliizocyjanurowej (PIR)","test_object_en":"Thermal insulation materials and products, including:  expanded cork products (IC)  expanded perlite products (EP)  phenolic foam products (PF)  extruded polystyrene products (XPS)  wood wool products (WW)  mineral wool products (MW)  wood fibre products (WF)  expanded polystyrene products (EPS)  cellular glass products (CG)  rigid polyurethane foam (PUR) and polyisocyanurate foam (PIR) products","methodology":"Opór cieplny Zakres: > 0,05 m2·K/W","methodology_en":"Thermal resistance Range: > 0,05 m2·K/W","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Opór cieplny Zakres: > 0,05 m2·K/W","reference":"PN-EN 12939:2002 p.1-6 „N”","norm_bases":["PN-EN 12939:2002 p.1-6 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały i wyroby do izolacji cieplnej, w tym:  wyroby z ekspandowanego korka (IC)  wyroby z ekspandowanego perlitu (EP)  wyroby z pianki fenolowej (PF)  wyroby z polistyrenu ekstrudowanego (XPS)  wyroby z wełny drzewnej (WW)  wyroby z wełny mineralnej (MW)  wyroby z włókien drzewnych (WF)  wyroby ze styropianu (EPS)  wyroby ze szkła piankowego (CG)  wyroby ze sztywnej pianki poliuretanowej (PUR) i pianki poliizocyjanurowej (PIR) Opór cieplny Zakres: > 0,05 m2·K/W PN-EN 12939:2002 p.1-6 „N” Materialy i wyroby do izolacji cieplnej, w tym:  wyroby z ekspandowanego korka (IC)  wyroby z ekspandowanego perlitu (EP)  wyroby z pianki fenolowej (PF)  wyroby z polistyrenu ekstrudowanego (XPS)  wyroby z welny drzewnej (WW)  wyroby z welny mineralnej (MW)  wyroby z wlokien drzewnych (WF)  wyroby ze styropianu (EPS)  wyroby ze szkla piankowego (CG)  wyroby ze sztywnej pianki poliuretanowej (PUR) i pianki poliizocyjanurowej (PIR) Opor cieplny Zakres: > 0,05 m2·K/W PN-EN 12939:2002 p.1-6 „N”","categories":["materials","construction"],"row_index":633,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation materials and products, including:  expanded cork products (IC)  expanded perlite products (EP)  phenolic foam products (PF)  extruded polystyrene products (XPS)  wood wool products (WW)  mineral wool products (MW)  wood fibre products (WF)  expanded polystyrene products (EPS)  cellular glass products (CG)  rigid polyurethane foam (PUR) and polyisocyanurate foam (PIR) products Thermal resistance Range: > 0,05 m2·K/W PN-EN 12939:2002 p.1-6 „N”","search_zh":"绝热材料与制品，其中包括：膨胀软木制品（IC）、膨胀珍珠岩制品（EP）、酚醛泡沫制品（PF）、挤塑聚苯乙烯制品（XPS）、木丝板制品（WW）、矿物棉制品（MW）、木纤维制品（WF）、模塑聚苯乙烯制品（EPS）、泡沫玻璃制品（CG）、硬质聚氨酯泡沫（PUR）与聚异氰脲酸酯泡沫（PIR）制品 PN-EN 12939:2002 p.1-6 „N”","test_object_zh":"绝热材料与制品，其中包括：膨胀软木制品（IC）、膨胀珍珠岩制品（EP）、酚醛泡沫制品（PF）、挤塑聚苯乙烯制品（XPS）、木丝板制品（WW）、矿物棉制品（MW）、木纤维制品（WF）、模塑聚苯乙烯制品（EPS）、泡沫玻璃制品（CG）、硬质聚氨酯泡沫（PUR）与聚异氰脲酸酯泡沫（PIR）制品"},{"_id":"6a5a55f19af9f73f3825118e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Materiały i wyroby do izolacji cieplnej, w tym:  wyroby z ekspandowanego korka (IC)  wyroby z ekspandowanego perlitu (EP)  wyroby z pianki fenolowej (PF)  wyroby z polistyrenu ekstrudowanego (XPS)  wyroby z wełny drzewnej (WW)  wyroby z wełny mineralnej (MW)  wyroby z włókien drzewnych (WF)  wyroby ze styropianu (EPS)  wyroby ze szkła piankowego (CG)  wyroby ze sztywnej pianki poliuretanowej (PUR) i pianki poliizocyjanurowej (PIR)","test_object_en":"Thermal insulation materials and products, including:  expanded cork products (IC)  expanded perlite products (EP)  phenolic foam products (PF)  extruded polystyrene products (XPS)  wood wool products (WW)  mineral wool products (MW)  wood fibre products (WF)  expanded polystyrene products (EPS)  cellular glass products (CG)  rigid polyurethane foam (PUR) and polyisocyanurate foam (PIR) products","methodology":"Przewodność cieplna Zakres: (0,015 - 0,060) W/(m·K)","methodology_en":"Thermal conductivity Range: (0,015 - 0,060) W/(m·K)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność cieplna Zakres: (0,015 - 0,060) W/(m·K)","reference":"PN-EN 12939:2002 p.1-6","norm_bases":["PN-EN 12939:2002 p.1-6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały i wyroby do izolacji cieplnej, w tym:  wyroby z ekspandowanego korka (IC)  wyroby z ekspandowanego perlitu (EP)  wyroby z pianki fenolowej (PF)  wyroby z polistyrenu ekstrudowanego (XPS)  wyroby z wełny drzewnej (WW)  wyroby z wełny mineralnej (MW)  wyroby z włókien drzewnych (WF)  wyroby ze styropianu (EPS)  wyroby ze szkła piankowego (CG)  wyroby ze sztywnej pianki poliuretanowej (PUR) i pianki poliizocyjanurowej (PIR) Przewodność cieplna Zakres: (0,015 - 0,060) W/(m·K) PN-EN 12939:2002 p.1-6 Materialy i wyroby do izolacji cieplnej, w tym:  wyroby z ekspandowanego korka (IC)  wyroby z ekspandowanego perlitu (EP)  wyroby z pianki fenolowej (PF)  wyroby z polistyrenu ekstrudowanego (XPS)  wyroby z welny drzewnej (WW)  wyroby z welny mineralnej (MW)  wyroby z wlokien drzewnych (WF)  wyroby ze styropianu (EPS)  wyroby ze szkla piankowego (CG)  wyroby ze sztywnej pianki poliuretanowej (PUR) i pianki poliizocyjanurowej (PIR) Przewodnosc cieplna Zakres: (0,015 - 0,060) W/(m·K) PN-EN 12939:2002 p.1-6","categories":["materials","construction"],"row_index":634,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation materials and products, including:  expanded cork products (IC)  expanded perlite products (EP)  phenolic foam products (PF)  extruded polystyrene products (XPS)  wood wool products (WW)  mineral wool products (MW)  wood fibre products (WF)  expanded polystyrene products (EPS)  cellular glass products (CG)  rigid polyurethane foam (PUR) and polyisocyanurate foam (PIR) products Thermal conductivity Range: (0,015 - 0,060) W/(m·K) PN-EN 12939:2002 p.1-6","search_zh":"绝热材料与制品，其中包括：膨胀软木制品（IC）、膨胀珍珠岩制品（EP）、酚醛泡沫制品（PF）、挤塑聚苯乙烯制品（XPS）、木丝板制品（WW）、矿物棉制品（MW）、木纤维制品（WF）、模塑聚苯乙烯制品（EPS）、泡沫玻璃制品（CG）、硬质聚氨酯泡沫（PUR）与聚异氰脲酸酯泡沫（PIR）制品 PN-EN 12939:2002 p.1-6","test_object_zh":"绝热材料与制品，其中包括：膨胀软木制品（IC）、膨胀珍珠岩制品（EP）、酚醛泡沫制品（PF）、挤塑聚苯乙烯制品（XPS）、木丝板制品（WW）、矿物棉制品（MW）、木纤维制品（WF）、模塑聚苯乙烯制品（EPS）、泡沫玻璃制品（CG）、硬质聚氨酯泡沫（PUR）与聚异氰脲酸酯泡沫（PIR）制品"},{"_id":"6a5a55f19af9f73f3825118f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Materiały i wyroby do izolacji cieplnej, w tym:  wyroby z ekspandowanego korka (IC)  wyroby z ekspandowanego perlitu (EP)  wyroby z pianki fenolowej (PF)  wyroby z polistyrenu ekstrudowanego (XPS)  wyroby z wełny drzewnej (WW)  wyroby z wełny mineralnej (MW)  wyroby z włókien drzewnych (WF)  wyroby ze styropianu (EPS)  wyroby ze szkła piankowego (CG)  wyroby ze sztywnej pianki poliuretanowej (PUR) i pianki poliizocyjanurowej (PIR)","test_object_en":"Thermal insulation materials and products, including:  expanded cork products (IC)  expanded perlite products (EP)  phenolic foam products (PF)  extruded polystyrene products (XPS)  wood wool products (WW)  mineral wool products (MW)  wood fibre products (WF)  expanded polystyrene products (EPS)  cellular glass products (CG)  rigid polyurethane foam (PUR) and polyisocyanurate foam (PIR) products","methodology":"Krótkotrwała nasiąkliwość wodą przy częściowym zanurzeniu próbki","methodology_en":"Short-term water absorption by partial immersion of the specimen","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Krótkotrwała nasiąkliwość wodą przy częściowym zanurzeniu próbki","reference":"PN-EN 1609:2013-07 „N”","norm_bases":["PN-EN 1609:2013-07 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały i wyroby do izolacji cieplnej, w tym:  wyroby z ekspandowanego korka (IC)  wyroby z ekspandowanego perlitu (EP)  wyroby z pianki fenolowej (PF)  wyroby z polistyrenu ekstrudowanego (XPS)  wyroby z wełny drzewnej (WW)  wyroby z wełny mineralnej (MW)  wyroby z włókien drzewnych (WF)  wyroby ze styropianu (EPS)  wyroby ze szkła piankowego (CG)  wyroby ze sztywnej pianki poliuretanowej (PUR) i pianki poliizocyjanurowej (PIR) Krótkotrwała nasiąkliwość wodą przy częściowym zanurzeniu próbki PN-EN 1609:2013-07 „N” Materialy i wyroby do izolacji cieplnej, w tym:  wyroby z ekspandowanego korka (IC)  wyroby z ekspandowanego perlitu (EP)  wyroby z pianki fenolowej (PF)  wyroby z polistyrenu ekstrudowanego (XPS)  wyroby z welny drzewnej (WW)  wyroby z welny mineralnej (MW)  wyroby z wlokien drzewnych (WF)  wyroby ze styropianu (EPS)  wyroby ze szkla piankowego (CG)  wyroby ze sztywnej pianki poliuretanowej (PUR) i pianki poliizocyjanurowej (PIR) Krotkotrwala nasiakliwosc woda przy czesciowym zanurzeniu probki PN-EN 1609:2013-07 „N”","categories":["materials","construction"],"row_index":635,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation materials and products, including:  expanded cork products (IC)  expanded perlite products (EP)  phenolic foam products (PF)  extruded polystyrene products (XPS)  wood wool products (WW)  mineral wool products (MW)  wood fibre products (WF)  expanded polystyrene products (EPS)  cellular glass products (CG)  rigid polyurethane foam (PUR) and polyisocyanurate foam (PIR) products Short-term water absorption by partial immersion of the specimen PN-EN 1609:2013-07 „N”","search_zh":"绝热材料与制品，其中包括：膨胀软木制品（IC）、膨胀珍珠岩制品（EP）、酚醛泡沫制品（PF）、挤塑聚苯乙烯制品（XPS）、木丝板制品（WW）、矿物棉制品（MW）、木纤维制品（WF）、模塑聚苯乙烯制品（EPS）、泡沫玻璃制品（CG）、硬质聚氨酯泡沫（PUR）与聚异氰脲酸酯泡沫（PIR）制品 PN-EN 1609:2013-07 „N”","test_object_zh":"绝热材料与制品，其中包括：膨胀软木制品（IC）、膨胀珍珠岩制品（EP）、酚醛泡沫制品（PF）、挤塑聚苯乙烯制品（XPS）、木丝板制品（WW）、矿物棉制品（MW）、木纤维制品（WF）、模塑聚苯乙烯制品（EPS）、泡沫玻璃制品（CG）、硬质聚氨酯泡沫（PUR）与聚异氰脲酸酯泡沫（PIR）制品"},{"_id":"6a5a55f19af9f73f38251190","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Materiały i wyroby do izolacji cieplnej, w tym:  wyroby z ekspandowanego korka (IC)  wyroby z ekspandowanego perlitu (EP)  wyroby z pianki fenolowej (PF)  wyroby z polistyrenu ekstrudowanego (XPS)  wyroby z wełny drzewnej (WW)  wyroby z wełny mineralnej (MW)  wyroby z włókien drzewnych (WF)  wyroby ze styropianu (EPS)  wyroby ze szkła piankowego (CG)  wyroby ze sztywnej pianki poliuretanowej (PUR) i pianki poliizocyjanurowej (PIR)","test_object_en":"Thermal insulation materials and products, including:  expanded cork products (IC)  expanded perlite products (EP)  phenolic foam products (PF)  extruded polystyrene products (XPS)  wood wool products (WW)  mineral wool products (MW)  wood fibre products (WF)  expanded polystyrene products (EPS)  cellular glass products (CG)  rigid polyurethane foam (PUR) and polyisocyanurate foam (PIR) products","methodology":"Długość i szerokość Wymiary geometryczne liniowe Zakres: (0 - 2000) mm","methodology_en":"Length and width Linear geometrical dimensions Range: (0 - 2000) mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Długość i szerokość Wymiary geometryczne liniowe Zakres: (0 - 2000) mm","reference":"PN-EN 12085:2013-07 PN-EN 822:2013-07 „N”","norm_bases":["PN-EN 12085:2013-07 PN-EN 822:2013-07 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały i wyroby do izolacji cieplnej, w tym:  wyroby z ekspandowanego korka (IC)  wyroby z ekspandowanego perlitu (EP)  wyroby z pianki fenolowej (PF)  wyroby z polistyrenu ekstrudowanego (XPS)  wyroby z wełny drzewnej (WW)  wyroby z wełny mineralnej (MW)  wyroby z włókien drzewnych (WF)  wyroby ze styropianu (EPS)  wyroby ze szkła piankowego (CG)  wyroby ze sztywnej pianki poliuretanowej (PUR) i pianki poliizocyjanurowej (PIR) Długość i szerokość Wymiary geometryczne liniowe Zakres: (0 - 2000) mm PN-EN 12085:2013-07 PN-EN 822:2013-07 „N” Materialy i wyroby do izolacji cieplnej, w tym:  wyroby z ekspandowanego korka (IC)  wyroby z ekspandowanego perlitu (EP)  wyroby z pianki fenolowej (PF)  wyroby z polistyrenu ekstrudowanego (XPS)  wyroby z welny drzewnej (WW)  wyroby z welny mineralnej (MW)  wyroby z wlokien drzewnych (WF)  wyroby ze styropianu (EPS)  wyroby ze szkla piankowego (CG)  wyroby ze sztywnej pianki poliuretanowej (PUR) i pianki poliizocyjanurowej (PIR) Dlugosc i szerokosc Wymiary geometryczne liniowe Zakres: (0 - 2000) mm PN-EN 12085:2013-07 PN-EN 822:2013-07 „N”","categories":["materials","construction"],"row_index":636,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation materials and products, including:  expanded cork products (IC)  expanded perlite products (EP)  phenolic foam products (PF)  extruded polystyrene products (XPS)  wood wool products (WW)  mineral wool products (MW)  wood fibre products (WF)  expanded polystyrene products (EPS)  cellular glass products (CG)  rigid polyurethane foam (PUR) and polyisocyanurate foam (PIR) products Length and width Linear geometrical dimensions Range: (0 - 2000) mm PN-EN 12085:2013-07 PN-EN 822:2013-07 „N”","search_zh":"绝热材料与制品，其中包括：膨胀软木制品（IC）、膨胀珍珠岩制品（EP）、酚醛泡沫制品（PF）、挤塑聚苯乙烯制品（XPS）、木丝板制品（WW）、矿物棉制品（MW）、木纤维制品（WF）、模塑聚苯乙烯制品（EPS）、泡沫玻璃制品（CG）、硬质聚氨酯泡沫（PUR）与聚异氰脲酸酯泡沫（PIR）制品 PN-EN 12085:2013-07 PN-EN 822:2013-07 „N”","test_object_zh":"绝热材料与制品，其中包括：膨胀软木制品（IC）、膨胀珍珠岩制品（EP）、酚醛泡沫制品（PF）、挤塑聚苯乙烯制品（XPS）、木丝板制品（WW）、矿物棉制品（MW）、木纤维制品（WF）、模塑聚苯乙烯制品（EPS）、泡沫玻璃制品（CG）、硬质聚氨酯泡沫（PUR）与聚异氰脲酸酯泡沫（PIR）制品"},{"_id":"6a5a55f19af9f73f38251191","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Materiały i wyroby do izolacji cieplnej, w tym:  wyroby z ekspandowanego korka (IC)  wyroby z ekspandowanego perlitu (EP)  wyroby z pianki fenolowej (PF)  wyroby z polistyrenu ekstrudowanego (XPS)  wyroby z wełny drzewnej (WW)  wyroby z wełny mineralnej (MW)  wyroby z włókien drzewnych (WF)  wyroby ze styropianu (EPS)  wyroby ze szkła piankowego (CG)  wyroby ze sztywnej pianki poliuretanowej (PUR) i pianki poliizocyjanurowej (PIR)","test_object_en":"Thermal insulation materials and products, including:  expanded cork products (IC)  expanded perlite products (EP)  phenolic foam products (PF)  extruded polystyrene products (XPS)  wood wool products (WW)  mineral wool products (MW)  wood fibre products (WF)  expanded polystyrene products (EPS)  cellular glass products (CG)  rigid polyurethane foam (PUR) and polyisocyanurate foam (PIR) products","methodology":"Grubość Zakres: (0 - 500) mm","methodology_en":"Thickness Range: (0 - 500) mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Grubość Zakres: (0 - 500) mm","reference":"PN-EN 823:2013-07 PN-EN 12085:2013-07 „N”","norm_bases":["PN-EN 823:2013-07 PN-EN 12085:2013-07 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały i wyroby do izolacji cieplnej, w tym:  wyroby z ekspandowanego korka (IC)  wyroby z ekspandowanego perlitu (EP)  wyroby z pianki fenolowej (PF)  wyroby z polistyrenu ekstrudowanego (XPS)  wyroby z wełny drzewnej (WW)  wyroby z wełny mineralnej (MW)  wyroby z włókien drzewnych (WF)  wyroby ze styropianu (EPS)  wyroby ze szkła piankowego (CG)  wyroby ze sztywnej pianki poliuretanowej (PUR) i pianki poliizocyjanurowej (PIR) Grubość Zakres: (0 - 500) mm PN-EN 823:2013-07 PN-EN 12085:2013-07 „N” Materialy i wyroby do izolacji cieplnej, w tym:  wyroby z ekspandowanego korka (IC)  wyroby z ekspandowanego perlitu (EP)  wyroby z pianki fenolowej (PF)  wyroby z polistyrenu ekstrudowanego (XPS)  wyroby z welny drzewnej (WW)  wyroby z welny mineralnej (MW)  wyroby z wlokien drzewnych (WF)  wyroby ze styropianu (EPS)  wyroby ze szkla piankowego (CG)  wyroby ze sztywnej pianki poliuretanowej (PUR) i pianki poliizocyjanurowej (PIR) Grubosc Zakres: (0 - 500) mm PN-EN 823:2013-07 PN-EN 12085:2013-07 „N”","categories":["materials","construction"],"row_index":637,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation materials and products, including:  expanded cork products (IC)  expanded perlite products (EP)  phenolic foam products (PF)  extruded polystyrene products (XPS)  wood wool products (WW)  mineral wool products (MW)  wood fibre products (WF)  expanded polystyrene products (EPS)  cellular glass products (CG)  rigid polyurethane foam (PUR) and polyisocyanurate foam (PIR) products Thickness Range: (0 - 500) mm PN-EN 823:2013-07 PN-EN 12085:2013-07 „N”","search_zh":"绝热材料与制品，其中包括：膨胀软木制品（IC）、膨胀珍珠岩制品（EP）、酚醛泡沫制品（PF）、挤塑聚苯乙烯制品（XPS）、木丝板制品（WW）、矿物棉制品（MW）、木纤维制品（WF）、模塑聚苯乙烯制品（EPS）、泡沫玻璃制品（CG）、硬质聚氨酯泡沫（PUR）与聚异氰脲酸酯泡沫（PIR）制品 PN-EN 823:2013-07 PN-EN 12085:2013-07 „N”","test_object_zh":"绝热材料与制品，其中包括：膨胀软木制品（IC）、膨胀珍珠岩制品（EP）、酚醛泡沫制品（PF）、挤塑聚苯乙烯制品（XPS）、木丝板制品（WW）、矿物棉制品（MW）、木纤维制品（WF）、模塑聚苯乙烯制品（EPS）、泡沫玻璃制品（CG）、硬质聚氨酯泡沫（PUR）与聚异氰脲酸酯泡沫（PIR）制品"},{"_id":"6a5a55f19af9f73f38251192","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Materiały i wyroby do izolacji cieplnej, w tym:  wyroby z ekspandowanego korka (IC)  wyroby z ekspandowanego perlitu (EP)  wyroby z pianki fenolowej (PF)  wyroby z polistyrenu ekstrudowanego (XPS)  wyroby z wełny drzewnej (WW)  wyroby z wełny mineralnej (MW)  wyroby z włókien drzewnych (WF)  wyroby ze styropianu (EPS)  wyroby ze szkła piankowego (CG)  wyroby ze sztywnej pianki poliuretanowej (PUR) i pianki poliizocyjanurowej (PIR)","test_object_en":"Thermal insulation materials and products, including:  expanded cork products (IC)  expanded perlite products (EP)  phenolic foam products (PF)  extruded polystyrene products (XPS)  wood wool products (WW)  mineral wool products (MW)  wood fibre products (WF)  expanded polystyrene products (EPS)  cellular glass products (CG)  rigid polyurethane foam (PUR) and polyisocyanurate foam (PIR) products","methodology":"Gęstość pozorna Metoda wagowa Zakres: 12000 g","methodology_en":"Apparent density Gravimetric method Range: 12000 g","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Gęstość pozorna Metoda wagowa Zakres: 12000 g","reference":"PN-EN 1602:2013-07","norm_bases":["PN-EN 1602:2013-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały i wyroby do izolacji cieplnej, w tym:  wyroby z ekspandowanego korka (IC)  wyroby z ekspandowanego perlitu (EP)  wyroby z pianki fenolowej (PF)  wyroby z polistyrenu ekstrudowanego (XPS)  wyroby z wełny drzewnej (WW)  wyroby z wełny mineralnej (MW)  wyroby z włókien drzewnych (WF)  wyroby ze styropianu (EPS)  wyroby ze szkła piankowego (CG)  wyroby ze sztywnej pianki poliuretanowej (PUR) i pianki poliizocyjanurowej (PIR) Gęstość pozorna Metoda wagowa Zakres: 12000 g PN-EN 1602:2013-07 Materialy i wyroby do izolacji cieplnej, w tym:  wyroby z ekspandowanego korka (IC)  wyroby z ekspandowanego perlitu (EP)  wyroby z pianki fenolowej (PF)  wyroby z polistyrenu ekstrudowanego (XPS)  wyroby z welny drzewnej (WW)  wyroby z welny mineralnej (MW)  wyroby z wlokien drzewnych (WF)  wyroby ze styropianu (EPS)  wyroby ze szkla piankowego (CG)  wyroby ze sztywnej pianki poliuretanowej (PUR) i pianki poliizocyjanurowej (PIR) Gestosc pozorna Metoda wagowa Zakres: 12000 g PN-EN 1602:2013-07","categories":["materials","construction"],"row_index":638,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation materials and products, including:  expanded cork products (IC)  expanded perlite products (EP)  phenolic foam products (PF)  extruded polystyrene products (XPS)  wood wool products (WW)  mineral wool products (MW)  wood fibre products (WF)  expanded polystyrene products (EPS)  cellular glass products (CG)  rigid polyurethane foam (PUR) and polyisocyanurate foam (PIR) products Apparent density Gravimetric method Range: 12000 g PN-EN 1602:2013-07","search_zh":"绝热材料与制品，其中包括：膨胀软木制品（IC）、膨胀珍珠岩制品（EP）、酚醛泡沫制品（PF）、挤塑聚苯乙烯制品（XPS）、木丝板制品（WW）、矿物棉制品（MW）、木纤维制品（WF）、模塑聚苯乙烯制品（EPS）、泡沫玻璃制品（CG）、硬质聚氨酯泡沫（PUR）与聚异氰脲酸酯泡沫（PIR）制品 PN-EN 1602:2013-07","test_object_zh":"绝热材料与制品，其中包括：膨胀软木制品（IC）、膨胀珍珠岩制品（EP）、酚醛泡沫制品（PF）、挤塑聚苯乙烯制品（XPS）、木丝板制品（WW）、矿物棉制品（MW）、木纤维制品（WF）、模塑聚苯乙烯制品（EPS）、泡沫玻璃制品（CG）、硬质聚氨酯泡沫（PUR）与聚异氰脲酸酯泡沫（PIR）制品"},{"_id":"6a5a55f19af9f73f38251193","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy wentylacyjne i inne obiekty o powierzchni mniejszej niż 1 m2 E","test_object_en":"Ventilation elements and other objects with an area of less than 1 m2 E","methodology":"Izolacyjność od dźwięków powietrznych elementów budowlanych Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna","methodology_en":"Airborne sound insulation of building elements Frequency range: (100 - 5000) Hz (measurement possible at 50, 63 and 80 Hz) Laboratory method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Izolacyjność od dźwięków powietrznych elementów budowlanych Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna","reference":"PN-EN 20140-10 PN-EN ISO 10140-2","norm_bases":["PN-EN 20140-10 PN-EN ISO 10140-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy wentylacyjne i inne obiekty o powierzchni mniejszej niż 1 m2 E Izolacyjność od dźwięków powietrznych elementów budowlanych Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna PN-EN 20140-10 PN-EN ISO 10140-2 Elementy wentylacyjne i inne obiekty o powierzchni mniejszej niz 1 m2 E Izolacyjnosc od dzwiekow powietrznych elementow budowlanych Zakres czestotliwosci: (100 - 5000) Hz (mozliwosc pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna PN-EN 20140-10 PN-EN ISO 10140-2","categories":["construction"],"row_index":639,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ventilation elements and other objects with an area of less than 1 m2 E Airborne sound insulation of building elements Frequency range: (100 - 5000) Hz (measurement possible at 50, 63 and 80 Hz) Laboratory method PN-EN 20140-10 PN-EN ISO 10140-2","methodology_zh":"建筑构件的空气声隔声性能 频率范围：(100 - 5000) Hz（可测 50、63 与 80 Hz） 实验室法","search_zh":"建筑构件的空气声隔声性能 频率范围：(100 - 5000) Hz（可测 50、63 与 80 Hz） 实验室法 PN-EN 20140-10 PN-EN ISO 10140-2"},{"_id":"6a5a55f19af9f73f38251194","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Ekrany drogowe E","test_object_en":"Road traffic screens E","methodology":"Izolacyjność akustyczna od dźwięków powietrznych Zakres częstotliwości: (100 - 5000) Hz Metoda laboratoryjna","methodology_en":"Airborne sound insulation Frequency range: (100 - 5000) Hz Laboratory method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Izolacyjność akustyczna od dźwięków powietrznych Zakres częstotliwości: (100 - 5000) Hz Metoda laboratoryjna","reference":"PN-EN 1793-2 „N” PN-EN 1793-3 „N”","norm_bases":["PN-EN 1793-2 „N” PN-EN 1793-3 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ekrany drogowe E Izolacyjność akustyczna od dźwięków powietrznych Zakres częstotliwości: (100 - 5000) Hz Metoda laboratoryjna PN-EN 1793-2 „N” PN-EN 1793-3 „N” Ekrany drogowe E Izolacyjnosc akustyczna od dzwiekow powietrznych Zakres czestotliwosci: (100 - 5000) Hz Metoda laboratoryjna PN-EN 1793-2 „N” PN-EN 1793-3 „N”","categories":["construction"],"row_index":640,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Road traffic screens E Airborne sound insulation Frequency range: (100 - 5000) Hz Laboratory method PN-EN 1793-2 „N” PN-EN 1793-3 „N”"},{"_id":"6a5a55f19af9f73f38251195","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Ekrany drogowe E","test_object_en":"Road traffic screens E","methodology":"Współczynnik pochłaniania dźwięku Zakres częstotliwości: (100 - 5000) Hz Metoda laboratoryjna","methodology_en":"Sound absorption coefficient Frequency range: (100 - 5000) Hz Laboratory method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Współczynnik pochłaniania dźwięku Zakres częstotliwości: (100 - 5000) Hz Metoda laboratoryjna","reference":"PN-EN 1793-1 „N” PN-EN 1793-3 „N”","norm_bases":["PN-EN 1793-1 „N” PN-EN 1793-3 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ekrany drogowe E Współczynnik pochłaniania dźwięku Zakres częstotliwości: (100 - 5000) Hz Metoda laboratoryjna PN-EN 1793-1 „N” PN-EN 1793-3 „N” Ekrany drogowe E Wspolczynnik pochlaniania dzwieku Zakres czestotliwosci: (100 - 5000) Hz Metoda laboratoryjna PN-EN 1793-1 „N” PN-EN 1793-3 „N”","categories":["other"],"row_index":641,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Road traffic screens E Sound absorption coefficient Frequency range: (100 - 5000) Hz Laboratory method PN-EN 1793-1 „N” PN-EN 1793-3 „N”"},{"_id":"6a5a55f19af9f73f38251196","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Materiały dźwiękochłonne Przedmioty i urządzenia stanowiące wyposażenie wnętrz Ustroje dźwiękochłonne E","test_object_en":"Sound-absorbing materials Objects and equipment forming interior furnishings Sound-absorbing structures E","methodology":"Współczynnik pochłaniania dźwięku w komorze pogłosowej Zakres częstotliwości: (100 - 5000) Hz Metoda laboratoryjna","methodology_en":"Sound absorption coefficient in a reverberation chamber Frequency range: (100 - 5000) Hz Laboratory method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Współczynnik pochłaniania dźwięku w komorze pogłosowej Zakres częstotliwości: (100 - 5000) Hz Metoda laboratoryjna","reference":"PN-EN ISO 354 „N” z wyłączeniem pkt. 7.3.1","norm_bases":["PN-EN ISO 354 „N” z wyłączeniem pkt. 7.3.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały dźwiękochłonne Przedmioty i urządzenia stanowiące wyposażenie wnętrz Ustroje dźwiękochłonne E Współczynnik pochłaniania dźwięku w komorze pogłosowej Zakres częstotliwości: (100 - 5000) Hz Metoda laboratoryjna PN-EN ISO 354 „N” z wyłączeniem pkt. 7.3.1 Materialy dzwiekochlonne Przedmioty i urzadzenia stanowiace wyposazenie wnetrz Ustroje dzwiekochlonne E Wspolczynnik pochlaniania dzwieku w komorze poglosowej Zakres czestotliwosci: (100 - 5000) Hz Metoda laboratoryjna PN-EN ISO 354 „N” z wylaczeniem pkt. 7.3.1","categories":["materials"],"row_index":642,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sound-absorbing materials Objects and equipment forming interior furnishings Sound-absorbing structures E Sound absorption coefficient in a reverberation chamber Frequency range: (100 - 5000) Hz Laboratory method PN-EN ISO 354 „N” z wyłączeniem pkt. 7.3.1"},{"_id":"6a5a55f19af9f73f38251197","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Materiały sprężyste (używane np. w pływających podłogach) E","test_object_en":"Resilient materials (used e.g. in floating floors) E","methodology":"Sztywność dynamiczna Zakres: (0,2 - 200) MN/m3 Metoda laboratoryjna","methodology_en":"Dynamic stiffness Range: (0,2 - 200) MN/m3 Laboratory method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sztywność dynamiczna Zakres: (0,2 - 200) MN/m3 Metoda laboratoryjna","reference":"PN-EN 29052-1","norm_bases":["PN-EN 29052-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały sprężyste (używane np. w pływających podłogach) E Sztywność dynamiczna Zakres: (0,2 - 200) MN/m3 Metoda laboratoryjna PN-EN 29052-1 Materialy sprezyste (uzywane np. w plywajacych podlogach) E Sztywnosc dynamiczna Zakres: (0,2 - 200) MN/m3 Metoda laboratoryjna PN-EN 29052-1","categories":["materials"],"row_index":643,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Resilient materials (used e.g. in floating floors) E Dynamic stiffness Range: (0,2 - 200) MN/m3 Laboratory method PN-EN 29052-1"},{"_id":"6a5a55f19af9f73f38251198","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Podłogi E","test_object_en":"Floors E","methodology":"Tłumienie dźwięków uderzeniowych przez podłogi na stropie wzorcowym Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna","methodology_en":"Impact sound insulation of floors on a standard floor Frequency range: (100 - 5000) Hz (measurement possible for 50, 63 and 80 Hz) Laboratory method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Tłumienie dźwięków uderzeniowych przez podłogi na stropie wzorcowym Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna","reference":"PN-EN ISO 10140-3","norm_bases":["PN-EN ISO 10140-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podłogi E Tłumienie dźwięków uderzeniowych przez podłogi na stropie wzorcowym Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna PN-EN ISO 10140-3 Podlogi E Tlumienie dzwiekow uderzeniowych przez podlogi na stropie wzorcowym Zakres czestotliwosci: (100 - 5000) Hz (mozliwosc pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna PN-EN ISO 10140-3","categories":["metrology"],"row_index":644,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Floors E Impact sound insulation of floors on a standard floor Frequency range: (100 - 5000) Hz (measurement possible for 50, 63 and 80 Hz) Laboratory method PN-EN ISO 10140-3"},{"_id":"6a5a55f19af9f73f38251199","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Pomieszczenia w budynku (wszystkie) E","test_object_en":"Rooms in a building (all) E","methodology":"Poziom dźwięku A (w budynku) Zakres: (22 - 137) dB in situ","methodology_en":"A-weighted sound level (in the building) Range: (22 - 137) dB in situ","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom dźwięku A (w budynku) Zakres: (22 - 137) dB in situ","reference":"PN-EN ISO 16032 PN-EN ISO 10052","norm_bases":["PN-EN ISO 16032 PN-EN ISO 10052"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomieszczenia w budynku (wszystkie) E Poziom dźwięku A (w budynku) Zakres: (22 - 137) dB in situ PN-EN ISO 16032 PN-EN ISO 10052 Pomieszczenia w budynku (wszystkie) E Poziom dzwieku A (w budynku) Zakres: (22 - 137) dB in situ PN-EN ISO 16032 PN-EN ISO 10052","categories":["other"],"row_index":645,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooms in a building (all) E A-weighted sound level (in the building) Range: (22 - 137) dB in situ PN-EN ISO 16032 PN-EN ISO 10052"},{"_id":"6a5a55f19af9f73f3825119a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Przegrody budowlane i ich elementy E","test_object_en":"Building partitions and their components E","methodology":"Izolacyjność akustyczna od dźwięków powietrznych i uderzeniowych Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna","methodology_en":"Airborne and impact sound insulation Frequency range: (100 - 5000) Hz (measurement possible for 50, 63 and 80 Hz) Laboratory method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Izolacyjność akustyczna od dźwięków powietrznych i uderzeniowych Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna","reference":"PN-EN ISO 10140-2 „N” PN-EN ISO 10140-3 „N”","norm_bases":["PN-EN ISO 10140-2 „N” PN-EN ISO 10140-3 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przegrody budowlane i ich elementy E Izolacyjność akustyczna od dźwięków powietrznych i uderzeniowych Zakres częstotliwości: (100 - 5000) Hz (możliwość pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna PN-EN ISO 10140-2 „N” PN-EN ISO 10140-3 „N” Przegrody budowlane i ich elementy E Izolacyjnosc akustyczna od dzwiekow powietrznych i uderzeniowych Zakres czestotliwosci: (100 - 5000) Hz (mozliwosc pomiaru dla 50, 63 i 80 Hz) Metoda laboratoryjna PN-EN ISO 10140-2 „N” PN-EN ISO 10140-3 „N”","categories":["construction"],"row_index":646,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building partitions and their components E Airborne and impact sound insulation Frequency range: (100 - 5000) Hz (measurement possible for 50, 63 and 80 Hz) Laboratory method PN-EN ISO 10140-2 „N” PN-EN ISO 10140-3 „N”"},{"_id":"6a5a55f19af9f73f3825119b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kontenerowe i/lub montowane na miejscu budowy oczyszczalnie ścieków E","test_object_en":"Packaged and/or site assembled wastewater treatment plants E","methodology":"Skuteczność oczyszczania Zakres OLM: do 50 także in situ","methodology_en":"Treatment efficiency OLM range: up to 50, also in situ","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność oczyszczania Zakres OLM: do 50 także in situ","reference":"PN-EN 12566-3 „N”","norm_bases":["PN-EN 12566-3 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kontenerowe i/lub montowane na miejscu budowy oczyszczalnie ścieków E Skuteczność oczyszczania Zakres OLM: do 50 także in situ PN-EN 12566-3 „N” Kontenerowe i/lub montowane na miejscu budowy oczyszczalnie sciekow E Skutecznosc oczyszczania Zakres OLM: do 50 takze in situ PN-EN 12566-3 „N”","categories":["water"],"row_index":647,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Packaged and/or site assembled wastewater treatment plants E Treatment efficiency OLM range: up to 50, also in situ PN-EN 12566-3 „N”","search_zh":"集装箱式和/或现场组装式污水处理装置 E PN-EN 12566-3 „N”","test_object_zh":"集装箱式和/或现场组装式污水处理装置 E"},{"_id":"6a5a55f19af9f73f3825119c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kontenerowe i/lub montowane na miejscu budowy oczyszczalnie ścieków E","test_object_en":"Packaged and/or site assembled wastewater treatment plants E","methodology":"Skuteczność oczyszczania - ścieki Biochemiczne zapotrzebowanie tlenu BZT 5 Zakres: (3 - 1200) mg/l O 2 Metoda miareczkowa","methodology_en":"Treatment efficiency - wastewater Biochemical oxygen demand BOD 5 Range: (3 - 1200) mg/l O 2 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność oczyszczania - ścieki Biochemiczne zapotrzebowanie tlenu BZT 5 Zakres: (3 - 1200) mg/l O 2 Metoda miareczkowa","reference":"PN-EN 1899-1 „N”","norm_bases":["PN-EN 1899-1 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kontenerowe i/lub montowane na miejscu budowy oczyszczalnie ścieków E Skuteczność oczyszczania - ścieki Biochemiczne zapotrzebowanie tlenu BZT 5 Zakres: (3 - 1200) mg/l O 2 Metoda miareczkowa PN-EN 1899-1 „N” Kontenerowe i/lub montowane na miejscu budowy oczyszczalnie sciekow E Skutecznosc oczyszczania - scieki Biochemiczne zapotrzebowanie tlenu BZT 5 Zakres: (3 - 1200) mg/l O 2 Metoda miareczkowa PN-EN 1899-1 „N”","categories":["water"],"row_index":648,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Packaged and/or site assembled wastewater treatment plants E Treatment efficiency - wastewater Biochemical oxygen demand BOD 5 Range: (3 - 1200) mg/l O 2 Titrimetric method PN-EN 1899-1 „N”","search_zh":"集装箱式和/或现场组装式污水处理装置 E PN-EN 1899-1 „N”","test_object_zh":"集装箱式和/或现场组装式污水处理装置 E"},{"_id":"6a5a55f19af9f73f3825119d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kontenerowe i/lub montowane na miejscu budowy oczyszczalnie ścieków E","test_object_en":"Packaged and/or site assembled wastewater treatment plants E","methodology":"Skuteczność oczyszczania - ścieki Chemiczne zapotrzebowanie tlenu ChZT-Cr Zakres: (30 - 7000) mg/l Metoda miareczkowa","methodology_en":"Treatment efficiency - wastewater Chemical oxygen demand COD-Cr Range: (30 - 7000) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność oczyszczania - ścieki Chemiczne zapotrzebowanie tlenu ChZT-Cr Zakres: (30 - 7000) mg/l Metoda miareczkowa","reference":"PN-ISO 6060 „N”","norm_bases":["PN-ISO 6060 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kontenerowe i/lub montowane na miejscu budowy oczyszczalnie ścieków E Skuteczność oczyszczania - ścieki Chemiczne zapotrzebowanie tlenu ChZT-Cr Zakres: (30 - 7000) mg/l Metoda miareczkowa PN-ISO 6060 „N” Kontenerowe i/lub montowane na miejscu budowy oczyszczalnie sciekow E Skutecznosc oczyszczania - scieki Chemiczne zapotrzebowanie tlenu ChZT-Cr Zakres: (30 - 7000) mg/l Metoda miareczkowa PN-ISO 6060 „N”","categories":["water"],"row_index":649,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Packaged and/or site assembled wastewater treatment plants E Treatment efficiency - wastewater Chemical oxygen demand COD-Cr Range: (30 - 7000) mg/l Titrimetric method PN-ISO 6060 „N”","search_zh":"集装箱式和/或现场组装式污水处理装置 E PN-ISO 6060 „N”","test_object_zh":"集装箱式和/或现场组装式污水处理装置 E"},{"_id":"6a5a55f19af9f73f3825119e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kontenerowe i/lub montowane na miejscu budowy oczyszczalnie ścieków E","test_object_en":"Packaged and/or site assembled wastewater treatment plants E","methodology":"Skuteczność oczyszczania - ścieki Chemiczne zapotrzebowanie tlenu Zakres: (5 - 10000) mg/l Metoda spektrofotometryczna","methodology_en":"Treatment efficiency - wastewater Chemical oxygen demand Range: (5 - 10000) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność oczyszczania - ścieki Chemiczne zapotrzebowanie tlenu Zakres: (5 - 10000) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 15705 „N”","norm_bases":["PN-ISO 15705 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kontenerowe i/lub montowane na miejscu budowy oczyszczalnie ścieków E Skuteczność oczyszczania - ścieki Chemiczne zapotrzebowanie tlenu Zakres: (5 - 10000) mg/l Metoda spektrofotometryczna PN-ISO 15705 „N” Kontenerowe i/lub montowane na miejscu budowy oczyszczalnie sciekow E Skutecznosc oczyszczania - scieki Chemiczne zapotrzebowanie tlenu Zakres: (5 - 10000) mg/l Metoda spektrofotometryczna PN-ISO 15705 „N”","categories":["water"],"row_index":650,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Packaged and/or site assembled wastewater treatment plants E Treatment efficiency - wastewater Chemical oxygen demand Range: (5 - 10000) mg/l Spectrophotometric method PN-ISO 15705 „N”","search_zh":"集装箱式和/或现场组装式污水处理装置 E PN-ISO 15705 „N”","test_object_zh":"集装箱式和/或现场组装式污水处理装置 E"},{"_id":"6a5a55f19af9f73f3825119f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kontenerowe i/lub montowane na miejscu budowy oczyszczalnie ścieków E","test_object_en":"Packaged and/or site assembled wastewater treatment plants E","methodology":"Skuteczność oczyszczania - ścieki Zawiesiny ogólne Zakres: (2,0 - 500) mg/l Metoda wagowa","methodology_en":"Treatment efficiency - wastewater Total suspended solids Range: (2,0 - 500) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność oczyszczania - ścieki Zawiesiny ogólne Zakres: (2,0 - 500) mg/l Metoda wagowa","reference":"PN-EN 872","norm_bases":["PN-EN 872"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kontenerowe i/lub montowane na miejscu budowy oczyszczalnie ścieków E Skuteczność oczyszczania - ścieki Zawiesiny ogólne Zakres: (2,0 - 500) mg/l Metoda wagowa PN-EN 872 Kontenerowe i/lub montowane na miejscu budowy oczyszczalnie sciekow E Skutecznosc oczyszczania - scieki Zawiesiny ogolne Zakres: (2,0 - 500) mg/l Metoda wagowa PN-EN 872","categories":["water"],"row_index":651,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Packaged and/or site assembled wastewater treatment plants E Treatment efficiency - wastewater Total suspended solids Range: (2,0 - 500) mg/l Gravimetric method PN-EN 872","search_zh":"集装箱式和/或现场组装式污水处理装置 E PN-EN 872","test_object_zh":"集装箱式和/或现场组装式污水处理装置 E"},{"_id":"6a5a55f19af9f73f382511a0","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kontenerowe i/lub montowane na miejscu budowy oczyszczalnie ścieków E","test_object_en":"Packaged and/or site assembled wastewater treatment plants E","methodology":"Skuteczność oczyszczania - ścieki Stężenie fosforu ogólnego Zakres: (0,30 - 14,0) mg/l Metoda spektrofotometryczna","methodology_en":"Treatment efficiency - wastewater Total phosphorus concentration Range: (0,30 - 14,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność oczyszczania - ścieki Stężenie fosforu ogólnego Zakres: (0,30 - 14,0) mg/l Metoda spektrofotometryczna","reference":"PN-EN ISO 6878","norm_bases":["PN-EN ISO 6878"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kontenerowe i/lub montowane na miejscu budowy oczyszczalnie ścieków E Skuteczność oczyszczania - ścieki Stężenie fosforu ogólnego Zakres: (0,30 - 14,0) mg/l Metoda spektrofotometryczna PN-EN ISO 6878 Kontenerowe i/lub montowane na miejscu budowy oczyszczalnie sciekow E Skutecznosc oczyszczania - scieki Stezenie fosforu ogolnego Zakres: (0,30 - 14,0) mg/l Metoda spektrofotometryczna PN-EN ISO 6878","categories":["water"],"row_index":652,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Packaged and/or site assembled wastewater treatment plants E Treatment efficiency - wastewater Total phosphorus concentration Range: (0,30 - 14,0) mg/l Spectrophotometric method PN-EN ISO 6878","search_zh":"集装箱式和/或现场组装式污水处理装置 E PN-EN ISO 6878","test_object_zh":"集装箱式和/或现场组装式污水处理装置 E"},{"_id":"6a5a55f19af9f73f382511a1","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kontenerowe i/lub montowane na miejscu budowy oczyszczalnie ścieków E","test_object_en":"Packaged and/or site assembled wastewater treatment plants E","methodology":"Skuteczność oczyszczania - ścieki pH Zakres: (3,0 - 10,0) Metoda potencjometryczna","methodology_en":"Treatment efficiency - wastewater pH Range: (3,0 - 10,0) Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność oczyszczania - ścieki pH Zakres: (3,0 - 10,0) Metoda potencjometryczna","reference":"PN-EN ISO 10523","norm_bases":["PN-EN ISO 10523"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kontenerowe i/lub montowane na miejscu budowy oczyszczalnie ścieków E Skuteczność oczyszczania - ścieki pH Zakres: (3,0 - 10,0) Metoda potencjometryczna PN-EN ISO 10523 Kontenerowe i/lub montowane na miejscu budowy oczyszczalnie sciekow E Skutecznosc oczyszczania - scieki pH Zakres: (3,0 - 10,0) Metoda potencjometryczna PN-EN ISO 10523","categories":["water"],"row_index":653,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Packaged and/or site assembled wastewater treatment plants E Treatment efficiency - wastewater pH Range: (3,0 - 10,0) Potentiometric method PN-EN ISO 10523","search_zh":"集装箱式和/或现场组装式污水处理装置 E PN-EN ISO 10523","test_object_zh":"集装箱式和/或现场组装式污水处理装置 E"},{"_id":"6a5a55f19af9f73f382511a2","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kontenerowe i/lub montowane na miejscu budowy oczyszczalnie ścieków E","test_object_en":"Packaged and/or site assembled wastewater treatment plants E","methodology":"Skuteczność oczyszczania - ścieki Przewodność elektryczna właściwa Zakres: (0,1 - 2) mS/cm Metoda konduktometryczna","methodology_en":"Treatment efficiency - wastewater Electrical conductivity Range: (0,1 - 2) mS/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność oczyszczania - ścieki Przewodność elektryczna właściwa Zakres: (0,1 - 2) mS/cm Metoda konduktometryczna","reference":"EN 27888","norm_bases":["EN 27888"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kontenerowe i/lub montowane na miejscu budowy oczyszczalnie ścieków E Skuteczność oczyszczania - ścieki Przewodność elektryczna właściwa Zakres: (0,1 - 2) mS/cm Metoda konduktometryczna EN 27888 Kontenerowe i/lub montowane na miejscu budowy oczyszczalnie sciekow E Skutecznosc oczyszczania - scieki Przewodnosc elektryczna wlasciwa Zakres: (0,1 - 2) mS/cm Metoda konduktometryczna EN 27888","categories":["water"],"row_index":654,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Packaged and/or site assembled wastewater treatment plants E Treatment efficiency - wastewater Electrical conductivity Range: (0,1 - 2) mS/cm Conductometric method EN 27888","search_zh":"集装箱式和/或现场组装式污水处理装置 E EN 27888","test_object_zh":"集装箱式和/或现场组装式污水处理装置 E"},{"_id":"6a5a55f19af9f73f382511a3","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kontenerowe i/lub montowane na miejscu budowy oczyszczalnie ścieków E","test_object_en":"Packaged and/or site assembled wastewater treatment plants E","methodology":"Wodoszczelność także in situ","methodology_en":"Watertightness also in situ","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność także in situ","reference":"PN-EN 12566-3 „N”","norm_bases":["PN-EN 12566-3 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kontenerowe i/lub montowane na miejscu budowy oczyszczalnie ścieków E Wodoszczelność także in situ PN-EN 12566-3 „N” Kontenerowe i/lub montowane na miejscu budowy oczyszczalnie sciekow E Wodoszczelnosc takze in situ PN-EN 12566-3 „N”","categories":["water"],"row_index":655,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Packaged and/or site assembled wastewater treatment plants E Watertightness also in situ PN-EN 12566-3 „N”","search_zh":"集装箱式和/或现场组装式污水处理装置 E PN-EN 12566-3 „N”","test_object_zh":"集装箱式和/或现场组装式污水处理装置 E"},{"_id":"6a5a55f19af9f73f382511a4","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Prefabrykowane osadniki gnilne E","test_object_en":"Prefabricated septic tanks E","methodology":"Przepustowość hydrauliczna","methodology_en":"Hydraulic capacity","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepustowość hydrauliczna","reference":"PN-EN 12566-1 „N”","norm_bases":["PN-EN 12566-1 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Prefabrykowane osadniki gnilne E Przepustowość hydrauliczna PN-EN 12566-1 „N” Prefabrykowane osadniki gnilne E Przepustowosc hydrauliczna PN-EN 12566-1 „N”","categories":["water"],"row_index":656,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Prefabricated septic tanks E Hydraulic capacity PN-EN 12566-1 „N”"},{"_id":"6a5a55f19af9f73f382511a5","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Prefabrykowane osadniki gnilne E","test_object_en":"Prefabricated septic tanks E","methodology":"Szczelność i pojemność nominalna także in situ","methodology_en":"Tightness and nominal capacity also in situ","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność i pojemność nominalna także in situ","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Prefabrykowane osadniki gnilne E Szczelność i pojemność nominalna także in situ Prefabrykowane osadniki gnilne E Szczelnosc i pojemnosc nominalna takze in situ","categories":["water"],"row_index":657,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Prefabricated septic tanks E Tightness and nominal capacity also in situ"},{"_id":"6a5a55f19af9f73f382511a6","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wysokociśnieniowe laminaty dekoracyjne (HPL) E","test_object_en":"High pressure decorative laminates (HPL) E","methodology":"Emisja formaldehydu Zakres: (0,005 - 15) mg/m3 Metoda komorowa","methodology_en":"Emission of formaldehyde Range: (0,005 - 15) mg/m3 Chamber method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja formaldehydu Zakres: (0,005 - 15) mg/m3 Metoda komorowa","reference":"PN-EN 717-1 „N” ISO 16000-3 „N”","norm_bases":["PN-EN 717-1 „N” ISO 16000-3 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wysokociśnieniowe laminaty dekoracyjne (HPL) E Emisja formaldehydu Zakres: (0,005 - 15) mg/m3 Metoda komorowa PN-EN 717-1 „N” ISO 16000-3 „N” Wysokocisnieniowe laminaty dekoracyjne (HPL) E Emisja formaldehydu Zakres: (0,005 - 15) mg/m3 Metoda komorowa PN-EN 717-1 „N” ISO 16000-3 „N”","categories":["environment"],"row_index":658,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"High pressure decorative laminates (HPL) E Emission of formaldehyde Range: (0,005 - 15) mg/m3 Chamber method PN-EN 717-1 „N” ISO 16000-3 „N”"},{"_id":"6a5a55f19af9f73f382511a7","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wysokociśnieniowe laminaty dekoracyjne (HPL) E","test_object_en":"High pressure decorative laminates (HPL) E","methodology":"Zawartość pentachlorofenolu Zakres: (0,1 - 25) mg/g Metoda chromatografii gazowej (GC- ECD)","methodology_en":"Pentachlorophenol content Range: (0,1 - 25) mg/g Gas chromatography (GC- ECD) method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość pentachlorofenolu Zakres: (0,1 - 25) mg/g Metoda chromatografii gazowej (GC- ECD)","reference":"EN/TR 14823 „N”","norm_bases":["EN/TR 14823 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wysokociśnieniowe laminaty dekoracyjne (HPL) E Zawartość pentachlorofenolu Zakres: (0,1 - 25) mg/g Metoda chromatografii gazowej (GC- ECD) EN/TR 14823 „N” Wysokocisnieniowe laminaty dekoracyjne (HPL) E Zawartosc pentachlorofenolu Zakres: (0,1 - 25) mg/g Metoda chromatografii gazowej (GC- ECD) EN/TR 14823 „N”","categories":["other"],"row_index":659,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"High pressure decorative laminates (HPL) E Pentachlorophenol content Range: (0,1 - 25) mg/g Gas chromatography (GC- ECD) method EN/TR 14823 „N”"},{"_id":"6a5a55f19af9f73f382511a8","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Prefabrykaty z betonu Maszty i słupy","test_object_en":"Precast concrete products Masts and poles","methodology":"Nośność przy jednoczesnym zginaniu i skręcaniu Zakres: do 200 kN Metoda zginania ze skręcaniem","methodology_en":"Load-bearing capacity under combined bending and torsion Range: up to 200 kN Bending with torsion method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność przy jednoczesnym zginaniu i skręcaniu Zakres: do 200 kN Metoda zginania ze skręcaniem","reference":"LW-014/2/02-2009","norm_bases":["LW-014/2/02-2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Prefabrykaty z betonu Maszty i słupy Nośność przy jednoczesnym zginaniu i skręcaniu Zakres: do 200 kN Metoda zginania ze skręcaniem LW-014/2/02-2009 Prefabrykaty z betonu Maszty i slupy Nosnosc przy jednoczesnym zginaniu i skrecaniu Zakres: do 200 kN Metoda zginania ze skrecaniem LW-014/2/02-2009","categories":["construction"],"row_index":660,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Precast concrete products Masts and poles Load-bearing capacity under combined bending and torsion Range: up to 200 kN Bending with torsion method LW-014/2/02-2009","search_zh":"混凝土预制件 桅杆与立柱 LW-014/2/02-2009","test_object_zh":"混凝土预制件 桅杆与立柱"},{"_id":"6a5a55f19af9f73f382511a9","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Prefabrykaty z betonu Maszty i słupy","test_object_en":"Precast concrete products Masts and poles","methodology":"Nośność przy skręcaniu Zakres: do 200 kN Metoda skręcania","methodology_en":"Load-bearing capacity under torsion Range: up to 200 kN Torsion method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność przy skręcaniu Zakres: do 200 kN Metoda skręcania","reference":"PN-EN 12843:2008 + PB LW-013/2/02-2009","norm_bases":["PN-EN 12843:2008 + PB LW-013/2/02-2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Prefabrykaty z betonu Maszty i słupy Nośność przy skręcaniu Zakres: do 200 kN Metoda skręcania PN-EN 12843:2008 + PB LW-013/2/02-2009 Prefabrykaty z betonu Maszty i slupy Nosnosc przy skrecaniu Zakres: do 200 kN Metoda skrecania PN-EN 12843:2008 + PB LW-013/2/02-2009","categories":["construction"],"row_index":661,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Precast concrete products Masts and poles Load-bearing capacity under torsion Range: up to 200 kN Torsion method PN-EN 12843:2008 + PB LW-013/2/02-2009","search_zh":"混凝土预制件 桅杆与立柱 PN-EN 12843:2008 + PB LW-013/2/02-2009","test_object_zh":"混凝土预制件 桅杆与立柱"},{"_id":"6a5a55f19af9f73f382511aa","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Prefabrykaty z betonu Maszty i słupy","test_object_en":"Precast concrete products Masts and poles","methodology":"Nośność przy zginaniu Zakres: do 200 kN Metoda zginania","methodology_en":"Load-bearing capacity under bending Range: up to 200 kN Bending method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność przy zginaniu Zakres: do 200 kN Metoda zginania","reference":"PN-EN 12843:2008 + PB LW-012/2/02-2009","norm_bases":["PN-EN 12843:2008 + PB LW-012/2/02-2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Prefabrykaty z betonu Maszty i słupy Nośność przy zginaniu Zakres: do 200 kN Metoda zginania PN-EN 12843:2008 + PB LW-012/2/02-2009 Prefabrykaty z betonu Maszty i slupy Nosnosc przy zginaniu Zakres: do 200 kN Metoda zginania PN-EN 12843:2008 + PB LW-012/2/02-2009","categories":["construction"],"row_index":662,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Precast concrete products Masts and poles Load-bearing capacity under bending Range: up to 200 kN Bending method PN-EN 12843:2008 + PB LW-012/2/02-2009","search_zh":"混凝土预制件 桅杆与立柱 PN-EN 12843:2008 + PB LW-012/2/02-2009","test_object_zh":"混凝土预制件 桅杆与立柱"},{"_id":"6a5a55f19af9f73f382511ab","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Surowce, materiały i wyroby budowlane","test_object_en":"Raw materials, building materials and construction products","methodology":"Stężenie aktywności radionuklidu: 40K Zakres: (60 - 25000) Bq/kg Metoda spektometrii promieniowania gamma","methodology_en":"Activity concentration of radionuclide: 40K Range: (60 - 25000) Bq/kg Gamma-ray spectrometry","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidu: 40K Zakres: (60 - 25000) Bq/kg Metoda spektometrii promieniowania gamma","reference":"PB–LZK 001/4/04-2021","norm_bases":["PB–LZK 001/4/04-2021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Surowce, materiały i wyroby budowlane Stężenie aktywności radionuklidu: 40K Zakres: (60 - 25000) Bq/kg Metoda spektometrii promieniowania gamma PB–LZK 001/4/04-2021 Surowce, materialy i wyroby budowlane Stezenie aktywnosci radionuklidu: 40K Zakres: (60 - 25000) Bq/kg Metoda spektometrii promieniowania gamma PB–LZK 001/4/04-2021","categories":["materials","construction"],"row_index":663,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Raw materials, building materials and construction products Activity concentration of radionuclide: 40K Range: (60 - 25000) Bq/kg Gamma-ray spectrometry PB–LZK 001/4/04-2021","search_zh":"建筑原料、材料与制品 PB–LZK 001/4/04-2021","test_object_zh":"建筑原料、材料与制品"},{"_id":"6a5a55f19af9f73f382511ac","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Surowce, materiały i wyroby budowlane","test_object_en":"Raw materials, building materials and construction products","methodology":"Stężenie aktywności radionuklidu: 214Bi Zakres: (15 - 9000) Bq/kg Metoda spektometrii promieniowania gamma","methodology_en":"Activity concentration of radionuclide: 214Bi Range: (15 - 9000) Bq/kg Gamma-ray spectrometry","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidu: 214Bi Zakres: (15 - 9000) Bq/kg Metoda spektometrii promieniowania gamma","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Surowce, materiały i wyroby budowlane Stężenie aktywności radionuklidu: 214Bi Zakres: (15 - 9000) Bq/kg Metoda spektometrii promieniowania gamma Surowce, materialy i wyroby budowlane Stezenie aktywnosci radionuklidu: 214Bi Zakres: (15 - 9000) Bq/kg Metoda spektometrii promieniowania gamma","categories":["materials","construction"],"row_index":664,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Raw materials, building materials and construction products Activity concentration of radionuclide: 214Bi Range: (15 - 9000) Bq/kg Gamma-ray spectrometry","search_zh":"建筑原料、材料与制品","test_object_zh":"建筑原料、材料与制品"},{"_id":"6a5a55f19af9f73f382511ad","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Surowce, materiały i wyroby budowlane","test_object_en":"Raw materials, building materials and construction products","methodology":"Stężenie aktywności radionuklidu: 208Tl Zakres: (7 - 12000) Bq/kg Metoda spektometrii promieniowania gamma","methodology_en":"Activity concentration of radionuclide: 208Tl Range: (7 - 12000) Bq/kg Gamma-ray spectrometry","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidu: 208Tl Zakres: (7 - 12000) Bq/kg Metoda spektometrii promieniowania gamma","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Surowce, materiały i wyroby budowlane Stężenie aktywności radionuklidu: 208Tl Zakres: (7 - 12000) Bq/kg Metoda spektometrii promieniowania gamma Surowce, materialy i wyroby budowlane Stezenie aktywnosci radionuklidu: 208Tl Zakres: (7 - 12000) Bq/kg Metoda spektometrii promieniowania gamma","categories":["materials","construction"],"row_index":665,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Raw materials, building materials and construction products Activity concentration of radionuclide: 208Tl Range: (7 - 12000) Bq/kg Gamma-ray spectrometry","search_zh":"建筑原料、材料与制品","test_object_zh":"建筑原料、材料与制品"},{"_id":"6a5a55f19af9f73f382511ae","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Surowce, materiały i wyroby budowlane","test_object_en":"Raw materials, building materials and construction products","methodology":"Stężenie aktywności radionuklidu: 226Ra (z obliczeń)","methodology_en":"Radionuclide activity concentration: 226Ra (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidu: 226Ra (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Surowce, materiały i wyroby budowlane Stężenie aktywności radionuklidu: 226Ra (z obliczeń) Surowce, materialy i wyroby budowlane Stezenie aktywnosci radionuklidu: 226Ra (z obliczen)","categories":["materials","construction"],"row_index":666,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Raw materials, building materials and construction products Radionuclide activity concentration: 226Ra (calculated)","methodology_zh":"放射性核素活度浓度：226Ra（计算得出）","search_zh":"建筑原料、材料与制品 放射性核素活度浓度：226Ra（计算得出）","test_object_zh":"建筑原料、材料与制品"},{"_id":"6a5a55f19af9f73f382511af","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Surowce, materiały i wyroby budowlane","test_object_en":"Raw materials, building materials and construction products","methodology":"Stężenie aktywności radionuklidu: 232Th (z obliczeń)","methodology_en":"Radionuclide activity concentration: 232Th (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidu: 232Th (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Surowce, materiały i wyroby budowlane Stężenie aktywności radionuklidu: 232Th (z obliczeń) Surowce, materialy i wyroby budowlane Stezenie aktywnosci radionuklidu: 232Th (z obliczen)","categories":["materials","construction"],"row_index":667,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Raw materials, building materials and construction products Radionuclide activity concentration: 232Th (calculated)","methodology_zh":"放射性核素活度浓度：232Th（计算得出）","search_zh":"建筑原料、材料与制品 放射性核素活度浓度：232Th（计算得出）","test_object_zh":"建筑原料、材料与制品"},{"_id":"6a5a55f19af9f73f382511b0","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Surowce, materiały i wyroby budowlane","test_object_en":"Raw materials, building materials and construction products","methodology":"Wskaźnik stężenia promieniotwórczego I (z obliczeń)","methodology_en":"Activity concentration index I (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik stężenia promieniotwórczego I (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Surowce, materiały i wyroby budowlane Wskaźnik stężenia promieniotwórczego I (z obliczeń) Surowce, materialy i wyroby budowlane Wskaznik stezenia promieniotworczego I (z obliczen)","categories":["materials","construction"],"row_index":668,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Raw materials, building materials and construction products Activity concentration index I (calculated)","methodology_zh":"放射性浓度指数 I（计算得出）","search_zh":"建筑原料、材料与制品 放射性浓度指数 I（计算得出）","test_object_zh":"建筑原料、材料与制品"},{"_id":"6a5a55f19af9f73f382511b1","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wsporcze elementy słupowe sieci trakcyjnej","test_object_en":"Supporting pole components of overhead contact lines","methodology":"Naprężenia i przemieszczenia metoda obliczeniowa","methodology_en":"Stresses and displacements calculation method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Naprężenia i przemieszczenia metoda obliczeniowa","reference":"LK-143/1/02-2014","norm_bases":["LK-143/1/02-2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wsporcze elementy słupowe sieci trakcyjnej Naprężenia i przemieszczenia metoda obliczeniowa LK-143/1/02-2014 Wsporcze elementy slupowe sieci trakcyjnej Naprezenia i przemieszczenia metoda obliczeniowa LK-143/1/02-2014","categories":["other"],"row_index":669,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Supporting pole components of overhead contact lines Stresses and displacements calculation method LK-143/1/02-2014"},{"_id":"6a5a55f19af9f73f382511b2","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zaprawy: cementowe gipsowe, wapienne, cementowo-wapienne, gipsowo-wapienne, do murów, masy tynkarskie do wypraw pocienionych","test_object_en":"Mortars: cement, gypsum, lime, cement-lime, gypsum-lime, masonry mortars, rendering compounds for thin-layer renders","methodology":"Mrozoodporność","methodology_en":"Frost resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Mrozoodporność","reference":"PN-B-04500 1985","norm_bases":["PN-B-04500 1985"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy: cementowe gipsowe, wapienne, cementowo-wapienne, gipsowo-wapienne, do murów, masy tynkarskie do wypraw pocienionych Mrozoodporność PN-B-04500 1985 Zaprawy: cementowe gipsowe, wapienne, cementowo-wapienne, gipsowo-wapienne, do murow, masy tynkarskie do wypraw pocienionych Mrozoodpornosc PN-B-04500 1985","categories":["construction"],"row_index":670,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mortars: cement, gypsum, lime, cement-lime, gypsum-lime, masonry mortars, rendering compounds for thin-layer renders Frost resistance PN-B-04500 1985","methodology_zh":"抗冻性","search_zh":"砂浆：水泥砂浆、石膏砂浆、石灰砂浆、水泥石灰砂浆、石膏石灰砂浆、砌筑砂浆、薄层抹面材料 抗冻性 PN-B-04500 1985","test_object_zh":"砂浆：水泥砂浆、石膏砂浆、石灰砂浆、水泥石灰砂浆、石膏石灰砂浆、砌筑砂浆、薄层抹面材料"},{"_id":"6a5a55f19af9f73f382511b3","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zaprawy: cementowe gipsowe, wapienne, cementowo-wapienne, gipsowo-wapienne, do murów, masy tynkarskie do wypraw pocienionych","test_object_en":"Mortars: cement, gypsum, lime, cement-lime, gypsum-lime, masonry mortars, rendering compounds for thin-layer renders","methodology":"Nasiąkliwość Zakres: (1 - 20)% Metoda wagowa","methodology_en":"Water absorption Range: (1 - 20)% Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nasiąkliwość Zakres: (1 - 20)% Metoda wagowa","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy: cementowe gipsowe, wapienne, cementowo-wapienne, gipsowo-wapienne, do murów, masy tynkarskie do wypraw pocienionych Nasiąkliwość Zakres: (1 - 20)% Metoda wagowa Zaprawy: cementowe gipsowe, wapienne, cementowo-wapienne, gipsowo-wapienne, do murow, masy tynkarskie do wypraw pocienionych Nasiakliwosc Zakres: (1 - 20)% Metoda wagowa","categories":["construction"],"row_index":671,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mortars: cement, gypsum, lime, cement-lime, gypsum-lime, masonry mortars, rendering compounds for thin-layer renders Water absorption Range: (1 - 20)% Gravimetric method","search_zh":"砂浆：水泥砂浆、石膏砂浆、石灰砂浆、水泥石灰砂浆、石膏石灰砂浆、砌筑砂浆、薄层抹面材料","test_object_zh":"砂浆：水泥砂浆、石膏砂浆、石灰砂浆、水泥石灰砂浆、石膏石灰砂浆、砌筑砂浆、薄层抹面材料"},{"_id":"6a5a55f19af9f73f382511b4","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zaprawy: cementowe gipsowe, wapienne, cementowo-wapienne, gipsowo-wapienne, do murów, masy tynkarskie do wypraw pocienionych","test_object_en":"Mortars: cement, gypsum, lime, cement-lime, gypsum-lime, masonry mortars, rendering compounds for thin-layer renders","methodology":"Skurcz Zakres: (0,00 - 20,00) mm/m","methodology_en":"Shrinkage Range: (0,00 - 20,00) mm/m","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skurcz Zakres: (0,00 - 20,00) mm/m","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy: cementowe gipsowe, wapienne, cementowo-wapienne, gipsowo-wapienne, do murów, masy tynkarskie do wypraw pocienionych Skurcz Zakres: (0,00 - 20,00) mm/m Zaprawy: cementowe gipsowe, wapienne, cementowo-wapienne, gipsowo-wapienne, do murow, masy tynkarskie do wypraw pocienionych Skurcz Zakres: (0,00 - 20,00) mm/m","categories":["construction"],"row_index":672,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mortars: cement, gypsum, lime, cement-lime, gypsum-lime, masonry mortars, rendering compounds for thin-layer renders Shrinkage Range: (0,00 - 20,00) mm/m","search_zh":"砂浆：水泥砂浆、石膏砂浆、石灰砂浆、水泥石灰砂浆、石膏石灰砂浆、砌筑砂浆、薄层抹面材料","test_object_zh":"砂浆：水泥砂浆、石膏砂浆、石灰砂浆、水泥石灰砂浆、石膏石灰砂浆、砌筑砂浆、薄层抹面材料"},{"_id":"6a5a55f19af9f73f382511b5","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Domieszki do betonu, zaprawy i zaczynu E","test_object_en":"Admixtures for concrete, mortar and grout E","methodology":"Zawartość alkaliów Zakres: (0,01 - 30,00)% Metoda fotometrii płomieniowej","methodology_en":"Alkali content Range: (0,01 - 30,00)% Flame photometry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość alkaliów Zakres: (0,01 - 30,00)% Metoda fotometrii płomieniowej","reference":"PN-EN 480-12","norm_bases":["PN-EN 480-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Domieszki do betonu, zaprawy i zaczynu E Zawartość alkaliów Zakres: (0,01 - 30,00)% Metoda fotometrii płomieniowej PN-EN 480-12 Domieszki do betonu, zaprawy i zaczynu E Zawartosc alkaliow Zakres: (0,01 - 30,00)% Metoda fotometrii plomieniowej PN-EN 480-12","categories":["construction"],"row_index":673,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Admixtures for concrete, mortar and grout E Alkali content Range: (0,01 - 30,00)% Flame photometry method PN-EN 480-12","search_zh":"混凝土、砂浆与净浆用外加剂 E PN-EN 480-12","test_object_zh":"混凝土、砂浆与净浆用外加剂 E"},{"_id":"6a5a55f19af9f73f382511b6","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Domieszki do betonu, zaprawy i zaczynu E","test_object_en":"Admixtures for concrete, mortar and grout E","methodology":"Zawartość chlorków Zakres: (0,001 - 30,00)% Metoda miareczkowa","methodology_en":"Chloride content Range: (0,001 - 30,00)% Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość chlorków Zakres: (0,001 - 30,00)% Metoda miareczkowa","reference":"PN-EN 480-10","norm_bases":["PN-EN 480-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Domieszki do betonu, zaprawy i zaczynu E Zawartość chlorków Zakres: (0,001 - 30,00)% Metoda miareczkowa PN-EN 480-10 Domieszki do betonu, zaprawy i zaczynu E Zawartosc chlorkow Zakres: (0,001 - 30,00)% Metoda miareczkowa PN-EN 480-10","categories":["construction"],"row_index":674,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Admixtures for concrete, mortar and grout E Chloride content Range: (0,001 - 30,00)% Titrimetric method PN-EN 480-10","search_zh":"混凝土、砂浆与净浆用外加剂 E PN-EN 480-10","test_object_zh":"混凝土、砂浆与净浆用外加剂 E"},{"_id":"6a5a55f19af9f73f382511b7","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Domieszki do betonu, zaprawy i zaczynu E","test_object_en":"Admixtures for concrete, mortar and grout E","methodology":"Zawartość powietrza w świeżej zaprawie Zakres: (0 - 30)% Metoda: ciśnieniowa","methodology_en":"Air content in fresh mortar Range: (0 - 30)% Method: pressure","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość powietrza w świeżej zaprawie Zakres: (0 - 30)% Metoda: ciśnieniowa","reference":"PN-EN 1015-7","norm_bases":["PN-EN 1015-7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Domieszki do betonu, zaprawy i zaczynu E Zawartość powietrza w świeżej zaprawie Zakres: (0 - 30)% Metoda: ciśnieniowa PN-EN 1015-7 Domieszki do betonu, zaprawy i zaczynu E Zawartosc powietrza w swiezej zaprawie Zakres: (0 - 30)% Metoda: cisnieniowa PN-EN 1015-7","categories":["construction"],"row_index":675,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Admixtures for concrete, mortar and grout E Air content in fresh mortar Range: (0 - 30)% Method: pressure PN-EN 1015-7","search_zh":"混凝土、砂浆与净浆用外加剂 E PN-EN 1015-7","test_object_zh":"混凝土、砂浆与净浆用外加剂 E"},{"_id":"6a5a55f19af9f73f382511b8","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Domieszki do betonu, zaprawy i zaczynu E","test_object_en":"Admixtures for concrete, mortar and grout E","methodology":"Zawartość powietrza Zakres: (0 - 30)% Metoda: ciśnieniomierza","methodology_en":"Air content Range: (0 - 30)% Method: pressure gauge","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość powietrza Zakres: (0 - 30)% Metoda: ciśnieniomierza","reference":"PN-EN 12350-7","norm_bases":["PN-EN 12350-7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Domieszki do betonu, zaprawy i zaczynu E Zawartość powietrza Zakres: (0 - 30)% Metoda: ciśnieniomierza PN-EN 12350-7 Domieszki do betonu, zaprawy i zaczynu E Zawartosc powietrza Zakres: (0 - 30)% Metoda: cisnieniomierza PN-EN 12350-7","categories":["construction"],"row_index":676,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Admixtures for concrete, mortar and grout E Air content Range: (0 - 30)% Method: pressure gauge PN-EN 12350-7","search_zh":"混凝土、砂浆与净浆用外加剂 E PN-EN 12350-7","test_object_zh":"混凝土、砂浆与净浆用外加剂 E"},{"_id":"6a5a55f19af9f73f382511b9","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Domieszki do betonu, zaprawy i zaczynu E","test_object_en":"Admixtures for concrete, mortar and grout E","methodology":"Konsystencja mieszanki betonowej kontrolnej i z domieszką Metoda opadu stożka Zakres: (10,0 - 300,00) mm","methodology_en":"Consistency of control concrete mix and mix with admixture Slump test method Range: (10,0 - 300,00) mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Konsystencja mieszanki betonowej kontrolnej i z domieszką Metoda opadu stożka Zakres: (10,0 - 300,00) mm","reference":"PN-EN 12350-2","norm_bases":["PN-EN 12350-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Domieszki do betonu, zaprawy i zaczynu E Konsystencja mieszanki betonowej kontrolnej i z domieszką Metoda opadu stożka Zakres: (10,0 - 300,00) mm PN-EN 12350-2 Domieszki do betonu, zaprawy i zaczynu E Konsystencja mieszanki betonowej kontrolnej i z domieszka Metoda opadu stozka Zakres: (10,0 - 300,00) mm PN-EN 12350-2","categories":["construction"],"row_index":677,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Admixtures for concrete, mortar and grout E Consistency of control concrete mix and mix with admixture Slump test method Range: (10,0 - 300,00) mm PN-EN 12350-2","search_zh":"混凝土、砂浆与净浆用外加剂 E PN-EN 12350-2","test_object_zh":"混凝土、砂浆与净浆用外加剂 E"},{"_id":"6a5a55f19af9f73f382511ba","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Domieszki do betonu, zaprawy i zaczynu E","test_object_en":"Admixtures for concrete, mortar and grout E","methodology":"Konsystencja mieszanki betonowej kontrolnej i z domieszką Metoda stolika rozpływowego Zakres: (340 - 620) mm","methodology_en":"Consistency of control concrete mix and mix with admixture Flow table method Range: (340 - 620) mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Konsystencja mieszanki betonowej kontrolnej i z domieszką Metoda stolika rozpływowego Zakres: (340 - 620) mm","reference":"PN-EN 12350-5","norm_bases":["PN-EN 12350-5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Domieszki do betonu, zaprawy i zaczynu E Konsystencja mieszanki betonowej kontrolnej i z domieszką Metoda stolika rozpływowego Zakres: (340 - 620) mm PN-EN 12350-5 Domieszki do betonu, zaprawy i zaczynu E Konsystencja mieszanki betonowej kontrolnej i z domieszka Metoda stolika rozplywowego Zakres: (340 - 620) mm PN-EN 12350-5","categories":["construction"],"row_index":678,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Admixtures for concrete, mortar and grout E Consistency of control concrete mix and mix with admixture Flow table method Range: (340 - 620) mm PN-EN 12350-5","search_zh":"混凝土、砂浆与净浆用外加剂 E PN-EN 12350-5","test_object_zh":"混凝土、砂浆与净浆用外加剂 E"},{"_id":"6a5a55f19af9f73f382511bb","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Domieszki do betonu, zaprawy i zaczynu E","test_object_en":"Admixtures for concrete, mortar and grout E","methodology":"Zmniejszenie ilości wody zarobowej Metoda opadu stożka","methodology_en":"Reduction of mixing water Slump method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zmniejszenie ilości wody zarobowej Metoda opadu stożka","reference":"PN-EN 12350-2","norm_bases":["PN-EN 12350-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Domieszki do betonu, zaprawy i zaczynu E Zmniejszenie ilości wody zarobowej Metoda opadu stożka PN-EN 12350-2 Domieszki do betonu, zaprawy i zaczynu E Zmniejszenie ilosci wody zarobowej Metoda opadu stozka PN-EN 12350-2","categories":["construction","water"],"row_index":679,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Admixtures for concrete, mortar and grout E Reduction of mixing water Slump method PN-EN 12350-2","search_zh":"混凝土、砂浆与净浆用外加剂 E PN-EN 12350-2","test_object_zh":"混凝土、砂浆与净浆用外加剂 E"},{"_id":"6a5a55f19af9f73f382511bc","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Domieszki do betonu, zaprawy i zaczynu E","test_object_en":"Admixtures for concrete, mortar and grout E","methodology":"Zmniejszenie ilości wody zarobowej Metoda stolika rozpływowego","methodology_en":"Reduction of mixing water Flow table method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zmniejszenie ilości wody zarobowej Metoda stolika rozpływowego","reference":"PN-EN 12350-5","norm_bases":["PN-EN 12350-5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Domieszki do betonu, zaprawy i zaczynu E Zmniejszenie ilości wody zarobowej Metoda stolika rozpływowego PN-EN 12350-5 Domieszki do betonu, zaprawy i zaczynu E Zmniejszenie ilosci wody zarobowej Metoda stolika rozplywowego PN-EN 12350-5","categories":["construction","water"],"row_index":680,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Admixtures for concrete, mortar and grout E Reduction of mixing water Flow table method PN-EN 12350-5","search_zh":"混凝土、砂浆与净浆用外加剂 E PN-EN 12350-5","test_object_zh":"混凝土、砂浆与净浆用外加剂 E"},{"_id":"6a5a55f19af9f73f382511bd","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Domieszki do betonu, zaprawy i zaczynu E","test_object_en":"Admixtures for concrete, mortar and grout E","methodology":"Zmniejszenie ilości wody","methodology_en":"Water reduction","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zmniejszenie ilości wody","reference":"PN-EN 1015-4","norm_bases":["PN-EN 1015-4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Domieszki do betonu, zaprawy i zaczynu E Zmniejszenie ilości wody PN-EN 1015-4 Domieszki do betonu, zaprawy i zaczynu E Zmniejszenie ilosci wody PN-EN 1015-4","categories":["construction","water"],"row_index":681,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Admixtures for concrete, mortar and grout E Water reduction PN-EN 1015-4","search_zh":"混凝土、砂浆与净浆用外加剂 E PN-EN 1015-4","test_object_zh":"混凝土、砂浆与净浆用外加剂 E"},{"_id":"6a5a55f19af9f73f382511be","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kostka brukowa betonowa E","test_object_en":"Concrete paving blocks E","methodology":"Nasiąkliwość Zakres: (0,0 - 20)% Metoda wagowa","methodology_en":"Water absorption Range: (0,0 - 20)% Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nasiąkliwość Zakres: (0,0 - 20)% Metoda wagowa","reference":"PN-EN 1338 zał. E","norm_bases":["PN-EN 1338 zał. E"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kostka brukowa betonowa E Nasiąkliwość Zakres: (0,0 - 20)% Metoda wagowa PN-EN 1338 zał. E Kostka brukowa betonowa E Nasiakliwosc Zakres: (0,0 - 20)% Metoda wagowa PN-EN 1338 zal. E","categories":["construction"],"row_index":682,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete paving blocks E Water absorption Range: (0,0 - 20)% Gravimetric method PN-EN 1338 zał. E","search_zh":"混凝土路面砖 E PN-EN 1338 zał. E","test_object_zh":"混凝土路面砖 E"},{"_id":"6a5a55f19af9f73f382511bf","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kostka brukowa betonowa E","test_object_en":"Concrete paving blocks E","methodology":"Odporność na ścieranie Zakres: (5 - 40) mm Metoda: szeroka tarcza ścierna","methodology_en":"Resistance to abrasion Range: (5 - 40) mm Method: wide abrasion wheel","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na ścieranie Zakres: (5 - 40) mm Metoda: szeroka tarcza ścierna","reference":"PN-EN 1338 zał. G","norm_bases":["PN-EN 1338 zał. G"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kostka brukowa betonowa E Odporność na ścieranie Zakres: (5 - 40) mm Metoda: szeroka tarcza ścierna PN-EN 1338 zał. G Kostka brukowa betonowa E Odpornosc na scieranie Zakres: (5 - 40) mm Metoda: szeroka tarcza scierna PN-EN 1338 zal. G","categories":["construction"],"row_index":683,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete paving blocks E Resistance to abrasion Range: (5 - 40) mm Method: wide abrasion wheel PN-EN 1338 zał. G","search_zh":"混凝土路面砖 E PN-EN 1338 zał. G","test_object_zh":"混凝土路面砖 E"},{"_id":"6a5a55f19af9f73f382511c0","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kostka brukowa betonowa E","test_object_en":"Concrete paving blocks E","methodology":"Odporność na ścieranie Zakres: (3000 - 35000) mm3/5000mm2 Metoda: tarcza Boehmego","methodology_en":"Resistance to abrasion Range: (3000 - 35000) mm3/5000mm2 Method: Böhme disc","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na ścieranie Zakres: (3000 - 35000) mm3/5000mm2 Metoda: tarcza Boehmego","reference":"PN-EN 1338 zał. H","norm_bases":["PN-EN 1338 zał. H"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kostka brukowa betonowa E Odporność na ścieranie Zakres: (3000 - 35000) mm3/5000mm2 Metoda: tarcza Boehmego PN-EN 1338 zał. H Kostka brukowa betonowa E Odpornosc na scieranie Zakres: (3000 - 35000) mm3/5000mm2 Metoda: tarcza Boehmego PN-EN 1338 zal. H","categories":["construction"],"row_index":684,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete paving blocks E Resistance to abrasion Range: (3000 - 35000) mm3/5000mm2 Method: Böhme disc PN-EN 1338 zał. H","search_zh":"混凝土路面砖 E PN-EN 1338 zał. H","test_object_zh":"混凝土路面砖 E"},{"_id":"6a5a55f19af9f73f382511c1","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kostka brukowa betonowa E","test_object_en":"Concrete paving blocks E","methodology":"Odporność na warunki atmosferyczne","methodology_en":"Weather resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na warunki atmosferyczne","reference":"PN-EN 1338 zał. D","norm_bases":["PN-EN 1338 zał. D"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kostka brukowa betonowa E Odporność na warunki atmosferyczne PN-EN 1338 zał. D Kostka brukowa betonowa E Odpornosc na warunki atmosferyczne PN-EN 1338 zal. D","categories":["construction"],"row_index":685,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete paving blocks E Weather resistance PN-EN 1338 zał. D","methodology_zh":"耐气候性","search_zh":"混凝土路面砖 E 耐气候性 PN-EN 1338 zał. D","test_object_zh":"混凝土路面砖 E"},{"_id":"6a5a55f19af9f73f382511c2","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Krawężniki betonowe E","test_object_en":"Concrete kerbs E","methodology":"Nasiąkliwość Metoda wagowa","methodology_en":"Water absorption Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nasiąkliwość Metoda wagowa","reference":"PN-EN 1340 zał. E","norm_bases":["PN-EN 1340 zał. E"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Krawężniki betonowe E Nasiąkliwość Metoda wagowa PN-EN 1340 zał. E Krawezniki betonowe E Nasiakliwosc Metoda wagowa PN-EN 1340 zal. E","categories":["construction"],"row_index":686,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete kerbs E Water absorption Gravimetric method PN-EN 1340 zał. E","search_zh":"混凝土路缘石 E 吸水率 重量法 PN-EN 1340 zał. E","test_object_zh":"混凝土路缘石 E","methodology_zh":"吸水率 重量法"},{"_id":"6a5a55f19af9f73f382511c3","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Krawężniki betonowe E","test_object_en":"Concrete kerbs E","methodology":"Odporność na ścieranie Zakres: (5 - 40) mm Metoda: szeroka tarcza ścierna","methodology_en":"Resistance to abrasion Range: (5 - 40) mm Method: wide abrasion wheel","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na ścieranie Zakres: (5 - 40) mm Metoda: szeroka tarcza ścierna","reference":"PN-EN 1340 zał. G","norm_bases":["PN-EN 1340 zał. G"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Krawężniki betonowe E Odporność na ścieranie Zakres: (5 - 40) mm Metoda: szeroka tarcza ścierna PN-EN 1340 zał. G Krawezniki betonowe E Odpornosc na scieranie Zakres: (5 - 40) mm Metoda: szeroka tarcza scierna PN-EN 1340 zal. G","categories":["construction"],"row_index":687,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete kerbs E Resistance to abrasion Range: (5 - 40) mm Method: wide abrasion wheel PN-EN 1340 zał. G","search_zh":"混凝土路缘石 E PN-EN 1340 zał. G","test_object_zh":"混凝土路缘石 E"},{"_id":"6a5a55f19af9f73f382511c4","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Krawężniki betonowe E","test_object_en":"Concrete kerbs E","methodology":"Odporność na ścieranie Zakres: (3000 - 35000) mm3/5000 mm2 Metoda: tarcza Boehmego","methodology_en":"Abrasion resistance Range: (3000 - 35000) mm3/5000 mm2 Method: Böhme disc","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na ścieranie Zakres: (3000 - 35000) mm3/5000 mm2 Metoda: tarcza Boehmego","reference":"PN-EN 1340 zał. H","norm_bases":["PN-EN 1340 zał. H"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Krawężniki betonowe E Odporność na ścieranie Zakres: (3000 - 35000) mm3/5000 mm2 Metoda: tarcza Boehmego PN-EN 1340 zał. H Krawezniki betonowe E Odpornosc na scieranie Zakres: (3000 - 35000) mm3/5000 mm2 Metoda: tarcza Boehmego PN-EN 1340 zal. H","categories":["construction"],"row_index":688,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete kerbs E Abrasion resistance Range: (3000 - 35000) mm3/5000 mm2 Method: Böhme disc PN-EN 1340 zał. H","search_zh":"混凝土路缘石 E PN-EN 1340 zał. H","test_object_zh":"混凝土路缘石 E"},{"_id":"6a5a55f19af9f73f382511c5","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Krawężniki betonowe E","test_object_en":"Concrete kerbs E","methodology":"Odporność na warunki atmosferyczne","methodology_en":"Weather resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na warunki atmosferyczne","reference":"PN-EN 1340 zał. D","norm_bases":["PN-EN 1340 zał. D"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Krawężniki betonowe E Odporność na warunki atmosferyczne PN-EN 1340 zał. D Krawezniki betonowe E Odpornosc na warunki atmosferyczne PN-EN 1340 zal. D","categories":["construction"],"row_index":689,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete kerbs E Weather resistance PN-EN 1340 zał. D","search_zh":"混凝土路缘石 E 耐气候性 PN-EN 1340 zał. D","test_object_zh":"混凝土路缘石 E","methodology_zh":"耐气候性"},{"_id":"6a5a55f19af9f73f382511c6","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty brukowe E","test_object_en":"Paving flags E","methodology":"Nasiąkliwość Zakres: (0,0 - 20)% Metoda wagowa","methodology_en":"Water absorption Range: (0,0 - 20)% Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nasiąkliwość Zakres: (0,0 - 20)% Metoda wagowa","reference":"PN-EN 1339 zał. E","norm_bases":["PN-EN 1339 zał. E"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty brukowe E Nasiąkliwość Zakres: (0,0 - 20)% Metoda wagowa PN-EN 1339 zał. E Plyty brukowe E Nasiakliwosc Zakres: (0,0 - 20)% Metoda wagowa PN-EN 1339 zal. E","categories":["other"],"row_index":690,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Paving flags E Water absorption Range: (0,0 - 20)% Gravimetric method PN-EN 1339 zał. E","search_zh":"铺路板 E PN-EN 1339 zał. E","test_object_zh":"铺路板 E"},{"_id":"6a5a55f19af9f73f382511c7","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty brukowe E","test_object_en":"Paving flags E","methodology":"Odporność na ścieranie Zakres: (5 - 30) mm Metoda: szeroka tarcza ścierna","methodology_en":"Abrasion resistance Range: (5 - 30) mm Method: wide abrasive wheel","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na ścieranie Zakres: (5 - 30) mm Metoda: szeroka tarcza ścierna","reference":"PN-EN 1339 zał. G","norm_bases":["PN-EN 1339 zał. G"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty brukowe E Odporność na ścieranie Zakres: (5 - 30) mm Metoda: szeroka tarcza ścierna PN-EN 1339 zał. G Plyty brukowe E Odpornosc na scieranie Zakres: (5 - 30) mm Metoda: szeroka tarcza scierna PN-EN 1339 zal. G","categories":["other"],"row_index":691,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Paving flags E Abrasion resistance Range: (5 - 30) mm Method: wide abrasive wheel PN-EN 1339 zał. G","search_zh":"铺路板 E PN-EN 1339 zał. G","test_object_zh":"铺路板 E"},{"_id":"6a5a55f19af9f73f382511c8","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty brukowe E","test_object_en":"Paving flags E","methodology":"Odporność na ścieranie Zakres: (3000 - 35000) mm3/5000mm2 Metoda: tarcza Boehmego","methodology_en":"Resistance to abrasion Range: (3000 - 35000) mm3/5000mm2 Method: Böhme disc","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na ścieranie Zakres: (3000 - 35000) mm3/5000mm2 Metoda: tarcza Boehmego","reference":"PN-EN 1339 zał. H","norm_bases":["PN-EN 1339 zał. H"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty brukowe E Odporność na ścieranie Zakres: (3000 - 35000) mm3/5000mm2 Metoda: tarcza Boehmego PN-EN 1339 zał. H Plyty brukowe E Odpornosc na scieranie Zakres: (3000 - 35000) mm3/5000mm2 Metoda: tarcza Boehmego PN-EN 1339 zal. H","categories":["other"],"row_index":692,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Paving flags E Resistance to abrasion Range: (3000 - 35000) mm3/5000mm2 Method: Böhme disc PN-EN 1339 zał. H","search_zh":"铺路板 E PN-EN 1339 zał. H","test_object_zh":"铺路板 E"},{"_id":"6a5a55f19af9f73f382511c9","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty brukowe E","test_object_en":"Paving flags E","methodology":"Odporność na warunki atmosferyczne","methodology_en":"Weather resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na warunki atmosferyczne","reference":"PN-EN 1339 zał. D","norm_bases":["PN-EN 1339 zał. D"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty brukowe E Odporność na warunki atmosferyczne PN-EN 1339 zał. D Plyty brukowe E Odpornosc na warunki atmosferyczne PN-EN 1339 zal. D","categories":["other"],"row_index":693,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Paving flags E Weather resistance PN-EN 1339 zał. D","methodology_zh":"耐气候性","search_zh":"铺路板 E 耐气候性 PN-EN 1339 zał. D","test_object_zh":"铺路板 E"},{"_id":"6a5a55f19af9f73f382511ca","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Beton E w tym: - beton komórkowy - beton lekki - beton żaroodporny - beton zwykły - beton hydrotechniczny - beton autoklawizowany - beton kruszywowy - inny","test_object_en":"Concrete E including: - aerated concrete - lightweight concrete - heat-resistant concrete - normal concrete - hydrotechnical concrete - autoclaved concrete - aggregate concrete - other","methodology":"Wytrzymałość na ściskanie Zakres sił: do 10 MN Próba ściskania","methodology_en":"Compressive strength Force range: up to 10 MN Compression test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie Zakres sił: do 10 MN Próba ściskania","reference":"PN-EN 12390-2 PN-EN 12390-3 PN-EN 12390-1 PN-EN 12504-1","norm_bases":["PN-EN 12390-2 PN-EN 12390-3 PN-EN 12390-1 PN-EN 12504-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton E w tym: - beton komórkowy - beton lekki - beton żaroodporny - beton zwykły - beton hydrotechniczny - beton autoklawizowany - beton kruszywowy - inny Wytrzymałość na ściskanie Zakres sił: do 10 MN Próba ściskania PN-EN 12390-2 PN-EN 12390-3 PN-EN 12390-1 PN-EN 12504-1 Beton E w tym: - beton komorkowy - beton lekki - beton zaroodporny - beton zwykly - beton hydrotechniczny - beton autoklawizowany - beton kruszywowy - inny Wytrzymalosc na sciskanie Zakres sil: do 10 MN Proba sciskania PN-EN 12390-2 PN-EN 12390-3 PN-EN 12390-1 PN-EN 12504-1","categories":["construction"],"row_index":694,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete E including: - aerated concrete - lightweight concrete - heat-resistant concrete - normal concrete - hydrotechnical concrete - autoclaved concrete - aggregate concrete - other Compressive strength Force range: up to 10 MN Compression test PN-EN 12390-2 PN-EN 12390-3 PN-EN 12390-1 PN-EN 12504-1","search_zh":"混凝土 E，其中包括：－ 加气混凝土 － 轻质混凝土 － 耐热混凝土 － 普通混凝土 － 水工混凝土 － 蒸压混凝土 － 集料混凝土 － 其他 PN-EN 12390-2 PN-EN 12390-3 PN-EN 12390-1 PN-EN 12504-1","test_object_zh":"混凝土 E，其中包括：－ 加气混凝土 － 轻质混凝土 － 耐热混凝土 － 普通混凝土 － 水工混凝土 － 蒸压混凝土 － 集料混凝土 － 其他"},{"_id":"6a5a55f19af9f73f382511cb","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Beton E w tym: - beton komórkowy - beton lekki - beton żaroodporny - beton zwykły - beton hydrotechniczny - beton autoklawizowany - beton kruszywowy - inny","test_object_en":"Concrete E including: - aerated concrete - lightweight concrete - heat-resistant concrete - normal concrete - hydrotechnical concrete - autoclaved concrete - aggregate concrete - other","methodology":"Wytrzymałość na rozciąganie przy rozłupywaniu Zakres sił: do 1 MN Próba ściskania","methodology_en":"Splitting tensile strength Force range: up to 1 MN Compression test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na rozciąganie przy rozłupywaniu Zakres sił: do 1 MN Próba ściskania","reference":"PN-EN 12390-6","norm_bases":["PN-EN 12390-6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton E w tym: - beton komórkowy - beton lekki - beton żaroodporny - beton zwykły - beton hydrotechniczny - beton autoklawizowany - beton kruszywowy - inny Wytrzymałość na rozciąganie przy rozłupywaniu Zakres sił: do 1 MN Próba ściskania PN-EN 12390-6 Beton E w tym: - beton komorkowy - beton lekki - beton zaroodporny - beton zwykly - beton hydrotechniczny - beton autoklawizowany - beton kruszywowy - inny Wytrzymalosc na rozciaganie przy rozlupywaniu Zakres sil: do 1 MN Proba sciskania PN-EN 12390-6","categories":["construction"],"row_index":695,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete E including: - aerated concrete - lightweight concrete - heat-resistant concrete - normal concrete - hydrotechnical concrete - autoclaved concrete - aggregate concrete - other Splitting tensile strength Force range: up to 1 MN Compression test PN-EN 12390-6","search_zh":"混凝土 E，其中包括：－ 加气混凝土 － 轻质混凝土 － 耐热混凝土 － 普通混凝土 － 水工混凝土 － 蒸压混凝土 － 集料混凝土 － 其他 PN-EN 12390-6","test_object_zh":"混凝土 E，其中包括：－ 加气混凝土 － 轻质混凝土 － 耐热混凝土 － 普通混凝土 － 水工混凝土 － 蒸压混凝土 － 集料混凝土 － 其他"},{"_id":"6a5a55f19af9f73f382511cc","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Beton E w tym: - beton komórkowy - beton lekki - beton żaroodporny - beton zwykły - beton hydrotechniczny - beton autoklawizowany - beton kruszywowy - inny","test_object_en":"Concrete E including: - aerated concrete - lightweight concrete - heat-resistant concrete - normal concrete - hydrotechnical concrete - autoclaved concrete - aggregate concrete - other","methodology":"Moduł sprężystości przy ściskaniu Zakres sił: 30 kN - 3000 kN Próba ściskania","methodology_en":"Modulus of elasticity in compression Force range: 30 kN - 3000 kN Compression test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moduł sprężystości przy ściskaniu Zakres sił: 30 kN - 3000 kN Próba ściskania","reference":"PN-EN 12390-13","norm_bases":["PN-EN 12390-13"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton E w tym: - beton komórkowy - beton lekki - beton żaroodporny - beton zwykły - beton hydrotechniczny - beton autoklawizowany - beton kruszywowy - inny Moduł sprężystości przy ściskaniu Zakres sił: 30 kN - 3000 kN Próba ściskania PN-EN 12390-13 Beton E w tym: - beton komorkowy - beton lekki - beton zaroodporny - beton zwykly - beton hydrotechniczny - beton autoklawizowany - beton kruszywowy - inny Modul sprezystosci przy sciskaniu Zakres sil: 30 kN - 3000 kN Proba sciskania PN-EN 12390-13","categories":["construction"],"row_index":696,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete E including: - aerated concrete - lightweight concrete - heat-resistant concrete - normal concrete - hydrotechnical concrete - autoclaved concrete - aggregate concrete - other Modulus of elasticity in compression Force range: 30 kN - 3000 kN Compression test PN-EN 12390-13","search_zh":"混凝土 E，其中包括：－ 加气混凝土 － 轻质混凝土 － 耐热混凝土 － 普通混凝土 － 水工混凝土 － 蒸压混凝土 － 集料混凝土 － 其他 PN-EN 12390-13","test_object_zh":"混凝土 E，其中包括：－ 加气混凝土 － 轻质混凝土 － 耐热混凝土 － 普通混凝土 － 水工混凝土 － 蒸压混凝土 － 集料混凝土 － 其他"},{"_id":"6a5a55f19af9f73f382511cd","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Blachy metalowe E","test_object_en":"Metal sheets E","methodology":"Wymiary geometryczne liniowe Zakres: do 5 m","methodology_en":"Linear geometric dimensions Range: up to 5 m","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary geometryczne liniowe Zakres: do 5 m","reference":"PN-EN 508-1","norm_bases":["PN-EN 508-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Blachy metalowe E Wymiary geometryczne liniowe Zakres: do 5 m PN-EN 508-1 Blachy metalowe E Wymiary geometryczne liniowe Zakres: do 5 m PN-EN 508-1","categories":["materials"],"row_index":697,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Metal sheets E Linear geometric dimensions Range: up to 5 m PN-EN 508-1"},{"_id":"6a5a55f19af9f73f382511ce","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Blachy metalowe E","test_object_en":"Metal sheets E","methodology":"Wytrzymałość na obciążenie skupione Zakres: do 10 kN Próba zginania","methodology_en":"Resistance to concentrated load Range: up to 10 kN Bending test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na obciążenie skupione Zakres: do 10 kN Próba zginania","reference":"PN-EN 14782","norm_bases":["PN-EN 14782"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Blachy metalowe E Wytrzymałość na obciążenie skupione Zakres: do 10 kN Próba zginania PN-EN 14782 Blachy metalowe E Wytrzymalosc na obciazenie skupione Zakres: do 10 kN Proba zginania PN-EN 14782","categories":["materials"],"row_index":698,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Metal sheets E Resistance to concentrated load Range: up to 10 kN Bending test PN-EN 14782"},{"_id":"6a5a55f19af9f73f382511cf","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drut stalowy E","test_object_en":"Steel wire E","methodology":"Odporność na przeginanie dwukierunkowe Zakres średnic drutów: (1,0 - 7,0) mm Próba przeginania","methodology_en":"Resistance to reverse bending Wire diameter range: (1,0 - 7,0) mm Bend test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na przeginanie dwukierunkowe Zakres średnic drutów: (1,0 - 7,0) mm Próba przeginania","reference":"PN-ISO 7801","norm_bases":["PN-ISO 7801"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drut stalowy E Odporność na przeginanie dwukierunkowe Zakres średnic drutów: (1,0 - 7,0) mm Próba przeginania PN-ISO 7801 Drut stalowy E Odpornosc na przeginanie dwukierunkowe Zakres srednic drutow: (1,0 - 7,0) mm Proba przeginania PN-ISO 7801","categories":["materials"],"row_index":699,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Steel wire E Resistance to reverse bending Wire diameter range: (1,0 - 7,0) mm Bend test PN-ISO 7801"},{"_id":"6a5a55f19af9f73f382511d0","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy murowe E w tym: - elementy z autoklawizowanego betonu komórkowego - elementy silikatowe - elementy ceramiczne - elementy betonowe - elementy gipsowe i inne","test_object_en":"Masonry units E including: - autoclaved aerated concrete units - calcium silicate units - clay units - concrete units - gypsum units and others","methodology":"Absorpcja Metoda podciągania kapilarnego Zakres: do 30% Metoda wagowa","methodology_en":"Absorption Capillary rise method Range: up to 30% Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Absorpcja Metoda podciągania kapilarnego Zakres: do 30% Metoda wagowa","reference":"PN-EN 772-11","norm_bases":["PN-EN 772-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy murowe E w tym: - elementy z autoklawizowanego betonu komórkowego - elementy silikatowe - elementy ceramiczne - elementy betonowe - elementy gipsowe i inne Absorpcja Metoda podciągania kapilarnego Zakres: do 30% Metoda wagowa PN-EN 772-11 Elementy murowe E w tym: - elementy z autoklawizowanego betonu komorkowego - elementy silikatowe - elementy ceramiczne - elementy betonowe - elementy gipsowe i inne Absorpcja Metoda podciagania kapilarnego Zakres: do 30% Metoda wagowa PN-EN 772-11","categories":["construction"],"row_index":700,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Masonry units E including: - autoclaved aerated concrete units - calcium silicate units - clay units - concrete units - gypsum units and others Absorption Capillary rise method Range: up to 30% Gravimetric method PN-EN 772-11"},{"_id":"6a5a55f19af9f73f382511d1","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy murowe E w tym: - elementy z autoklawizowanego betonu komórkowego - elementy silikatowe - elementy ceramiczne - elementy betonowe - elementy gipsowe i inne","test_object_en":"Masonry units E including: - autoclaved aerated concrete units - calcium silicate units - clay units - concrete units - gypsum units and others","methodology":"Gęstość netto i brutto Zakres: do 2500 kg/m3","methodology_en":"Net and gross density Range: up to 2500 kg/m3","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Gęstość netto i brutto Zakres: do 2500 kg/m3","reference":"PN-EN 772-13","norm_bases":["PN-EN 772-13"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy murowe E w tym: - elementy z autoklawizowanego betonu komórkowego - elementy silikatowe - elementy ceramiczne - elementy betonowe - elementy gipsowe i inne Gęstość netto i brutto Zakres: do 2500 kg/m3 PN-EN 772-13 Elementy murowe E w tym: - elementy z autoklawizowanego betonu komorkowego - elementy silikatowe - elementy ceramiczne - elementy betonowe - elementy gipsowe i inne Gestosc netto i brutto Zakres: do 2500 kg/m3 PN-EN 772-13","categories":["construction"],"row_index":701,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Masonry units E including: - autoclaved aerated concrete units - calcium silicate units - clay units - concrete units - gypsum units and others Net and gross density Range: up to 2500 kg/m3 PN-EN 772-13"},{"_id":"6a5a55f19af9f73f382511d2","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Liniowe kanały odwadniające, korytka z pokrywą, korytka szczelinowe, korytka krawężnikowe E","test_object_en":"Linear drainage channels, covered channels, slotted channels, kerb channels E","methodology":"Odkształcenia trwałe Zakres: do 10 mm Metoda pomiar liniowy","methodology_en":"Permanent deformations Range: up to 10 mm Method linear measurement","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odkształcenia trwałe Zakres: do 10 mm Metoda pomiar liniowy","reference":"PN-EN 1433 „N”","norm_bases":["PN-EN 1433 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Liniowe kanały odwadniające, korytka z pokrywą, korytka szczelinowe, korytka krawężnikowe E Odkształcenia trwałe Zakres: do 10 mm Metoda pomiar liniowy PN-EN 1433 „N” Liniowe kanaly odwadniajace, korytka z pokrywa, korytka szczelinowe, korytka kraweznikowe E Odksztalcenia trwale Zakres: do 10 mm Metoda pomiar liniowy PN-EN 1433 „N”","categories":["other"],"row_index":702,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Linear drainage channels, covered channels, slotted channels, kerb channels E Permanent deformations Range: up to 10 mm Method linear measurement PN-EN 1433 „N”","search_zh":"线性排水沟、带盖沟槽、缝隙式沟槽、路缘石式沟槽 E PN-EN 1433 „N”","test_object_zh":"线性排水沟、带盖沟槽、缝隙式沟槽、路缘石式沟槽 E"},{"_id":"6a5a55f19af9f73f382511d3","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Liniowe kanały odwadniające, korytka z pokrywą, korytka szczelinowe, korytka krawężnikowe E","test_object_en":"Linear drainage channels, covered channels, slotted channels, kerb channels E","methodology":"Wodoszczelność Ocena makroskopowa","methodology_en":"Watertightness Macroscopic assessment","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność Ocena makroskopowa","reference":"PN-EN 1433 „N”","norm_bases":["PN-EN 1433 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Liniowe kanały odwadniające, korytka z pokrywą, korytka szczelinowe, korytka krawężnikowe E Wodoszczelność Ocena makroskopowa PN-EN 1433 „N” Liniowe kanaly odwadniajace, korytka z pokrywa, korytka szczelinowe, korytka kraweznikowe E Wodoszczelnosc Ocena makroskopowa PN-EN 1433 „N”","categories":["other"],"row_index":703,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Linear drainage channels, covered channels, slotted channels, kerb channels E Watertightness Macroscopic assessment PN-EN 1433 „N”","search_zh":"线性排水沟、带盖沟槽、缝隙式沟槽、路缘石式沟槽 E PN-EN 1433 „N”","test_object_zh":"线性排水沟、带盖沟槽、缝隙式沟槽、路缘石式沟槽 E"},{"_id":"6a5a55f19af9f73f382511d4","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Liniowe kanały odwadniające, korytka z pokrywą, korytka szczelinowe, korytka krawężnikowe E","test_object_en":"Linear drainage channels, covered channels, slotted channels, kerb channels E","methodology":"Wytrzymałość na obciążenia próbne Zakres: do 5 MN Próba ściskania","methodology_en":"Resistance to test loads Range: up to 5 MN Compression test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na obciążenia próbne Zakres: do 5 MN Próba ściskania","reference":"PN-EN 1433 „N”","norm_bases":["PN-EN 1433 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Liniowe kanały odwadniające, korytka z pokrywą, korytka szczelinowe, korytka krawężnikowe E Wytrzymałość na obciążenia próbne Zakres: do 5 MN Próba ściskania PN-EN 1433 „N” Liniowe kanaly odwadniajace, korytka z pokrywa, korytka szczelinowe, korytka kraweznikowe E Wytrzymalosc na obciazenia probne Zakres: do 5 MN Proba sciskania PN-EN 1433 „N”","categories":["other"],"row_index":704,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Linear drainage channels, covered channels, slotted channels, kerb channels E Resistance to test loads Range: up to 5 MN Compression test PN-EN 1433 „N”","search_zh":"线性排水沟、带盖沟槽、缝隙式沟槽、路缘石式沟槽 E PN-EN 1433 „N”","test_object_zh":"线性排水沟、带盖沟槽、缝隙式沟槽、路缘石式沟槽 E"},{"_id":"6a5a55f19af9f73f382511d5","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Mury E w tym: - wyroby dodatkowe do wznoszenia murów","test_object_en":"Masonry E including: - ancillary components for masonry","methodology":"Nośność na wyrywanie z zaprawy prefabrykowanego zbrojenia do spoin wspornych","methodology_en":"Pull-out load-bearing capacity from mortar of prefabricated bed joint reinforcement","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność na wyrywanie z zaprawy prefabrykowanego zbrojenia do spoin wspornych","reference":"PN-EN 846-2 „N”","norm_bases":["PN-EN 846-2 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mury E w tym: - wyroby dodatkowe do wznoszenia murów Nośność na wyrywanie z zaprawy prefabrykowanego zbrojenia do spoin wspornych PN-EN 846-2 „N” Mury E w tym: - wyroby dodatkowe do wznoszenia murow Nosnosc na wyrywanie z zaprawy prefabrykowanego zbrojenia do spoin wspornych PN-EN 846-2 „N”","categories":["other"],"row_index":705,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Masonry E including: - ancillary components for masonry Pull-out load-bearing capacity from mortar of prefabricated bed joint reinforcement PN-EN 846-2 „N”","search_zh":"砌体 E，其中包括：－ 砌筑用辅助制品 PN-EN 846-2 „N”","test_object_zh":"砌体 E，其中包括：－ 砌筑用辅助制品"},{"_id":"6a5a55f19af9f73f382511d6","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Mury E w tym: - wyroby dodatkowe do wznoszenia murów","test_object_en":"Masonry E including: - ancillary components for masonry","methodology":"Wytrzymałość murów na ściskanie i moduł sprężystości Zakres do: długość - 1,5 m, szerokość – 0,45 m, wysokość - 6 m, siły – 5 MN Próba ściskania","methodology_en":"Compressive strength of masonry and modulus of elasticity Range up to: length - 1,5 m, width – 0,45 m, height - 6 m, force – 5 MN Compression test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość murów na ściskanie i moduł sprężystości Zakres do: długość - 1,5 m, szerokość – 0,45 m, wysokość - 6 m, siły – 5 MN Próba ściskania","reference":"PN-EN 1052-1","norm_bases":["PN-EN 1052-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mury E w tym: - wyroby dodatkowe do wznoszenia murów Wytrzymałość murów na ściskanie i moduł sprężystości Zakres do: długość - 1,5 m, szerokość – 0,45 m, wysokość - 6 m, siły – 5 MN Próba ściskania PN-EN 1052-1 Mury E w tym: - wyroby dodatkowe do wznoszenia murow Wytrzymalosc murow na sciskanie i modul sprezystosci Zakres do: dlugosc - 1,5 m, szerokosc – 0,45 m, wysokosc - 6 m, sily – 5 MN Proba sciskania PN-EN 1052-1","categories":["other"],"row_index":706,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Masonry E including: - ancillary components for masonry Compressive strength of masonry and modulus of elasticity Range up to: length - 1,5 m, width – 0,45 m, height - 6 m, force – 5 MN Compression test PN-EN 1052-1","search_zh":"砌体 E，其中包括：－ 砌筑用辅助制品 PN-EN 1052-1","test_object_zh":"砌体 E，其中包括：－ 砌筑用辅助制品"},{"_id":"6a5a55f19af9f73f382511d7","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Mury E w tym: - wyroby dodatkowe do wznoszenia murów","test_object_en":"Masonry E including: - ancillary components for masonry","methodology":"Wytrzymałość na rozciąganie przy zginaniu Zakres: 2 x 200 kN Próba zginania","methodology_en":"Flexural tensile strength Range: 2 x 200 kN Bending test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na rozciąganie przy zginaniu Zakres: 2 x 200 kN Próba zginania","reference":"PN-EN 1052-2","norm_bases":["PN-EN 1052-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mury E w tym: - wyroby dodatkowe do wznoszenia murów Wytrzymałość na rozciąganie przy zginaniu Zakres: 2 x 200 kN Próba zginania PN-EN 1052-2 Mury E w tym: - wyroby dodatkowe do wznoszenia murow Wytrzymalosc na rozciaganie przy zginaniu Zakres: 2 x 200 kN Proba zginania PN-EN 1052-2","categories":["other"],"row_index":707,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Masonry E including: - ancillary components for masonry Flexural tensile strength Range: 2 x 200 kN Bending test PN-EN 1052-2","search_zh":"砌体 E，其中包括：－ 砌筑用辅助制品 PN-EN 1052-2","test_object_zh":"砌体 E，其中包括：－ 砌筑用辅助制品"},{"_id":"6a5a55f19af9f73f382511d8","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Mury E w tym: - wyroby dodatkowe do wznoszenia murów","test_object_en":"Masonry E including: - ancillary components for masonry","methodology":"Wytrzymałość na rozciąganie przy zginaniu Metoda skręcania Zakres: 2 x 200 kN Próba zginania","methodology_en":"Flexural tensile strength Torsion method Range: 2 x 200 kN Bending test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na rozciąganie przy zginaniu Metoda skręcania Zakres: 2 x 200 kN Próba zginania","reference":"PN-EN 1052-5","norm_bases":["PN-EN 1052-5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mury E w tym: - wyroby dodatkowe do wznoszenia murów Wytrzymałość na rozciąganie przy zginaniu Metoda skręcania Zakres: 2 x 200 kN Próba zginania PN-EN 1052-5 Mury E w tym: - wyroby dodatkowe do wznoszenia murow Wytrzymalosc na rozciaganie przy zginaniu Metoda skrecania Zakres: 2 x 200 kN Proba zginania PN-EN 1052-5","categories":["other"],"row_index":708,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Masonry E including: - ancillary components for masonry Flexural tensile strength Torsion method Range: 2 x 200 kN Bending test PN-EN 1052-5","search_zh":"砌体 E，其中包括：－ 砌筑用辅助制品 PN-EN 1052-5","test_object_zh":"砌体 E，其中包括：－ 砌筑用辅助制品"},{"_id":"6a5a55f19af9f73f382511d9","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Mury E w tym: - wyroby dodatkowe do wznoszenia murów","test_object_en":"Masonry E including: - ancillary components for masonry","methodology":"Wytrzymałość na ścinanie Zakres: 2 x 200 kN Próba zginania","methodology_en":"Shear strength Range: 2 x 200 kN Bending test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ścinanie Zakres: 2 x 200 kN Próba zginania","reference":"PN-EN 1052-3 PN-EN 1052-4","norm_bases":["PN-EN 1052-3 PN-EN 1052-4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mury E w tym: - wyroby dodatkowe do wznoszenia murów Wytrzymałość na ścinanie Zakres: 2 x 200 kN Próba zginania PN-EN 1052-3 PN-EN 1052-4 Mury E w tym: - wyroby dodatkowe do wznoszenia murow Wytrzymalosc na scinanie Zakres: 2 x 200 kN Proba zginania PN-EN 1052-3 PN-EN 1052-4","categories":["other"],"row_index":709,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Masonry E including: - ancillary components for masonry Shear strength Range: 2 x 200 kN Bending test PN-EN 1052-3 PN-EN 1052-4","search_zh":"砌体 E，其中包括：－ 砌筑用辅助制品 PN-EN 1052-3 PN-EN 1052-4","test_object_zh":"砌体 E，其中包括：－ 砌筑用辅助制品"},{"_id":"6a5a55f19af9f73f382511da","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Nadproża E","test_object_en":"Lintels E","methodology":"Nośność Zakres: do 4 x 200 kN Próba ścinania","methodology_en":"Load-bearing capacity Range: up to 4 x 200 kN Shear test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność Zakres: do 4 x 200 kN Próba ścinania","reference":"PN-EN 846-9 „N” PN-EN 845-2 „N”","norm_bases":["PN-EN 846-9 „N” PN-EN 845-2 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Nadproża E Nośność Zakres: do 4 x 200 kN Próba ścinania PN-EN 846-9 „N” PN-EN 845-2 „N” Nadproza E Nosnosc Zakres: do 4 x 200 kN Proba scinania PN-EN 846-9 „N” PN-EN 845-2 „N”","categories":["other"],"row_index":710,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Lintels E Load-bearing capacity Range: up to 4 x 200 kN Shear test PN-EN 846-9 „N” PN-EN 845-2 „N”","search_zh":"过梁 E PN-EN 846-9 „N” PN-EN 845-2 „N”","test_object_zh":"过梁 E"},{"_id":"6a5a55f19af9f73f382511db","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Nadproża E","test_object_en":"Lintels E","methodology":"Obciążenie zginające Pd odpowiadające ustalonemu ugięciu dd Zakres: do 4 x 200 kN Próba zginania","methodology_en":"Bending load Pd corresponding to a specified deflection dd Range: up to 4 x 200 kN Bending test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Obciążenie zginające Pd odpowiadające ustalonemu ugięciu dd Zakres: do 4 x 200 kN Próba zginania","reference":"PN-EN 846-9 „N” PN-EN 845-2 „N”","norm_bases":["PN-EN 846-9 „N” PN-EN 845-2 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Nadproża E Obciążenie zginające Pd odpowiadające ustalonemu ugięciu dd Zakres: do 4 x 200 kN Próba zginania PN-EN 846-9 „N” PN-EN 845-2 „N” Nadproza E Obciazenie zginajace Pd odpowiadajace ustalonemu ugieciu dd Zakres: do 4 x 200 kN Proba zginania PN-EN 846-9 „N” PN-EN 845-2 „N”","categories":["other"],"row_index":711,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Lintels E Bending load Pd corresponding to a specified deflection dd Range: up to 4 x 200 kN Bending test PN-EN 846-9 „N” PN-EN 845-2 „N”","search_zh":"过梁 E PN-EN 846-9 „N” PN-EN 845-2 „N”","test_object_zh":"过梁 E"},{"_id":"6a5a55f19af9f73f382511dc","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Nadproża E","test_object_en":"Lintels E","methodology":"Trwałość Zakres: do 300 mm Pomiary liniowe","methodology_en":"Durability Range: up to 300 mm Linear measurements","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość Zakres: do 300 mm Pomiary liniowe","reference":"PN-EN 845-2 „N”","norm_bases":["PN-EN 845-2 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Nadproża E Trwałość Zakres: do 300 mm Pomiary liniowe PN-EN 845-2 „N” Nadproza E Trwalosc Zakres: do 300 mm Pomiary liniowe PN-EN 845-2 „N”","categories":["other"],"row_index":712,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Lintels E Durability Range: up to 300 mm Linear measurements PN-EN 845-2 „N”","search_zh":"过梁 E PN-EN 845-2 „N”","test_object_zh":"过梁 E"},{"_id":"6a5a55f19af9f73f382511dd","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Nadproża E","test_object_en":"Lintels E","methodology":"Własności materiałowe Zakres do 5 MN Próba ściskania","methodology_en":"Material properties Range up to 5 MN Compression test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Własności materiałowe Zakres do 5 MN Próba ściskania","reference":"PN-EN 845-2 „N”","norm_bases":["PN-EN 845-2 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Nadproża E Własności materiałowe Zakres do 5 MN Próba ściskania PN-EN 845-2 „N” Nadproza E Wlasnosci materialowe Zakres do 5 MN Proba sciskania PN-EN 845-2 „N”","categories":["materials"],"row_index":713,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Lintels E Material properties Range up to 5 MN Compression test PN-EN 845-2 „N”","search_zh":"过梁 E PN-EN 845-2 „N”","test_object_zh":"过梁 E"},{"_id":"6a5a55f19af9f73f382511de","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Nadproża E","test_object_en":"Lintels E","methodology":"Wymiary geometryczne liniowe Zakres: do 5 m Pomiary liniowe","methodology_en":"Linear geometric dimensions Range: up to 5 m Linear measurements","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary geometryczne liniowe Zakres: do 5 m Pomiary liniowe","reference":"PN-EN 845-2 „N” PN-EN 846-11","norm_bases":["PN-EN 845-2 „N” PN-EN 846-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Nadproża E Wymiary geometryczne liniowe Zakres: do 5 m Pomiary liniowe PN-EN 845-2 „N” PN-EN 846-11 Nadproza E Wymiary geometryczne liniowe Zakres: do 5 m Pomiary liniowe PN-EN 845-2 „N” PN-EN 846-11","categories":["other"],"row_index":714,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Lintels E Linear geometric dimensions Range: up to 5 m Linear measurements PN-EN 845-2 „N” PN-EN 846-11","search_zh":"过梁 E PN-EN 845-2 „N” PN-EN 846-11","test_object_zh":"过梁 E"},{"_id":"6a5a55f19af9f73f382511df","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Nadproża E","test_object_en":"Lintels E","methodology":"Określanie początkowej wytrzymałości na ścinanie pomiędzy częścią prefabrykowaną nadproża warstwowego a murem powyżej niego Wartości tabelaryczne","methodology_en":"Determination of the initial shear strength between the prefabricated part of a composite lintel and the masonry above it Tabulated values","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Określanie początkowej wytrzymałości na ścinanie pomiędzy częścią prefabrykowaną nadproża warstwowego a murem powyżej niego Wartości tabelaryczne","reference":"PN-EN 846-14 „N”","norm_bases":["PN-EN 846-14 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Nadproża E Określanie początkowej wytrzymałości na ścinanie pomiędzy częścią prefabrykowaną nadproża warstwowego a murem powyżej niego Wartości tabelaryczne PN-EN 846-14 „N” Nadproza E Okreslanie poczatkowej wytrzymalosci na scinanie pomiedzy czescia prefabrykowana nadproza warstwowego a murem powyzej niego Wartosci tabelaryczne PN-EN 846-14 „N”","categories":["other"],"row_index":715,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Lintels E Determination of the initial shear strength between the prefabricated part of a composite lintel and the masonry above it Tabulated values PN-EN 846-14 „N”","search_zh":"过梁 E PN-EN 846-14 „N”","test_object_zh":"过梁 E"},{"_id":"6a5a55f19af9f73f382511e0","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Słupy oświetleniowe E","test_object_en":"Lighting columns E","methodology":"Nośność i odkształcalność Zakres: do 200 kN Metoda skręcania / skręcania ze zginaniem lub Metoda obliczeniowa","methodology_en":"Load-bearing capacity and deformability Range: up to 200 kN Torsion / torsion with bending method or Calculation method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność i odkształcalność Zakres: do 200 kN Metoda skręcania / skręcania ze zginaniem lub Metoda obliczeniowa","reference":"PN-EN 40-3-1 PN-EN 40-3-2 PN-EN 40-3-3 PN-EN 40-5 PN-EN 40-6 PN-EN 40-7 PN-EN 40-4","norm_bases":["PN-EN 40-3-1 PN-EN 40-3-2 PN-EN 40-3-3 PN-EN 40-5 PN-EN 40-6 PN-EN 40-7 PN-EN 40-4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Słupy oświetleniowe E Nośność i odkształcalność Zakres: do 200 kN Metoda skręcania / skręcania ze zginaniem lub Metoda obliczeniowa PN-EN 40-3-1 PN-EN 40-3-2 PN-EN 40-3-3 PN-EN 40-5 PN-EN 40-6 PN-EN 40-7 PN-EN 40-4 Slupy oswietleniowe E Nosnosc i odksztalcalnosc Zakres: do 200 kN Metoda skrecania / skrecania ze zginaniem lub Metoda obliczeniowa PN-EN 40-3-1 PN-EN 40-3-2 PN-EN 40-3-3 PN-EN 40-5 PN-EN 40-6 PN-EN 40-7 PN-EN 40-4","categories":["other"],"row_index":716,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Lighting columns E Load-bearing capacity and deformability Range: up to 200 kN Torsion / torsion with bending method or Calculation method PN-EN 40-3-1 PN-EN 40-3-2 PN-EN 40-3-3 PN-EN 40-5 PN-EN 40-6 PN-EN 40-7 PN-EN 40-4"},{"_id":"6a5a55f19af9f73f382511e1","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Sploty, druty do konstrukcji sprężanych E","test_object_en":"Strands, wires for prestressed structures E","methodology":"Odporność na korozję naprężeniową Zakres obciążeń: do 200 kN i średnic do 18 mm Metoda roztworu A Metoda roztworu B","methodology_en":"Resistance to stress corrosion Load range: up to 200 kN and diameters up to 18 mm Solution A method Solution B method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na korozję naprężeniową Zakres obciążeń: do 200 kN i średnic do 18 mm Metoda roztworu A Metoda roztworu B","reference":"PN-EN ISO 15630-3","norm_bases":["PN-EN ISO 15630-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Sploty, druty do konstrukcji sprężanych E Odporność na korozję naprężeniową Zakres obciążeń: do 200 kN i średnic do 18 mm Metoda roztworu A Metoda roztworu B PN-EN ISO 15630-3 Sploty, druty do konstrukcji sprezanych E Odpornosc na korozje naprezeniowa Zakres obciazen: do 200 kN i srednic do 18 mm Metoda roztworu A Metoda roztworu B PN-EN ISO 15630-3","categories":["other"],"row_index":717,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Strands, wires for prestressed structures E Resistance to stress corrosion Load range: up to 200 kN and diameters up to 18 mm Solution A method Solution B method PN-EN ISO 15630-3","search_zh":"预应力结构用钢绞线与钢丝 E PN-EN ISO 15630-3","test_object_zh":"预应力结构用钢绞线与钢丝 E"},{"_id":"6a5a55f19af9f73f382511e2","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Sploty, druty do konstrukcji sprężanych E","test_object_en":"Strands, wires for prestressed structures E","methodology":"Relaksacja Zakres: do 200 kN obciążenia i do 18 mm średnicy","methodology_en":"Relaxation Range: up to 200 kN of load and up to 18 mm of diameter","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Relaksacja Zakres: do 200 kN obciążenia i do 18 mm średnicy","reference":"PN-EN ISO 15630-3","norm_bases":["PN-EN ISO 15630-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Sploty, druty do konstrukcji sprężanych E Relaksacja Zakres: do 200 kN obciążenia i do 18 mm średnicy PN-EN ISO 15630-3 Sploty, druty do konstrukcji sprezanych E Relaksacja Zakres: do 200 kN obciazenia i do 18 mm srednicy PN-EN ISO 15630-3","categories":["other"],"row_index":718,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Strands, wires for prestressed structures E Relaxation Range: up to 200 kN of load and up to 18 mm of diameter PN-EN ISO 15630-3","search_zh":"预应力结构用钢绞线与钢丝 E PN-EN ISO 15630-3","test_object_zh":"预应力结构用钢绞线与钢丝 E"},{"_id":"6a5a55f19af9f73f382511e3","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Sploty, druty do konstrukcji sprężanych E","test_object_en":"Strands, wires for prestressed structures E","methodology":"Próba rozciągania z odginaniem Zakres siły: (50 - 1000) kN i średnic do 18 mm Metoda rozciągania","methodology_en":"Tensile test with back-bending Force range: (50 - 1000) kN and diameters up to 18 mm Tensile method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Próba rozciągania z odginaniem Zakres siły: (50 - 1000) kN i średnic do 18 mm Metoda rozciągania","reference":"PN-EN-ISO 15630-3","norm_bases":["PN-EN-ISO 15630-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Sploty, druty do konstrukcji sprężanych E Próba rozciągania z odginaniem Zakres siły: (50 - 1000) kN i średnic do 18 mm Metoda rozciągania PN-EN-ISO 15630-3 Sploty, druty do konstrukcji sprezanych E Proba rozciagania z odginaniem Zakres sily: (50 - 1000) kN i srednic do 18 mm Metoda rozciagania PN-EN-ISO 15630-3","categories":["other"],"row_index":719,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Strands, wires for prestressed structures E Tensile test with back-bending Force range: (50 - 1000) kN and diameters up to 18 mm Tensile method PN-EN-ISO 15630-3","search_zh":"预应力结构用钢绞线与钢丝 E PN-EN-ISO 15630-3","test_object_zh":"预应力结构用钢绞线与钢丝 E"},{"_id":"6a5a55f19af9f73f382511e4","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stal zbrojeniowa E","test_object_en":"Reinforcing steel E","methodology":"Odporność na ścinanie połączenia zgrzewanego stali do zbrojenia betonu Zakres: do 1000 kN Metoda ścinania","methodology_en":"Shear resistance of the welded joint of steel for the reinforcement of concrete Range: up to 1000 kN Shear method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na ścinanie połączenia zgrzewanego stali do zbrojenia betonu Zakres: do 1000 kN Metoda ścinania","reference":"PN-EN ISO 15630-2","norm_bases":["PN-EN ISO 15630-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stal zbrojeniowa E Odporność na ścinanie połączenia zgrzewanego stali do zbrojenia betonu Zakres: do 1000 kN Metoda ścinania PN-EN ISO 15630-2 Stal zbrojeniowa E Odpornosc na scinanie polaczenia zgrzewanego stali do zbrojenia betonu Zakres: do 1000 kN Metoda scinania PN-EN ISO 15630-2","categories":["materials","construction"],"row_index":720,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Reinforcing steel E Shear resistance of the welded joint of steel for the reinforcement of concrete Range: up to 1000 kN Shear method PN-EN ISO 15630-2","search_zh":"配筋用钢 E PN-EN ISO 15630-2","test_object_zh":"配筋用钢 E"},{"_id":"6a5a55f19af9f73f382511e5","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stal zbrojeniowa E","test_object_en":"Reinforcing steel E","methodology":"Odporność na ścinanie połączenia zgrzewanego dźwigarów kratowych Zakres: do 100 kN Metoda ścinania","methodology_en":"Shear resistance of the welded joint of lattice girders Range: up to 100 kN Shear method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na ścinanie połączenia zgrzewanego dźwigarów kratowych Zakres: do 100 kN Metoda ścinania","reference":"PN-EN 10080","norm_bases":["PN-EN 10080"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stal zbrojeniowa E Odporność na ścinanie połączenia zgrzewanego dźwigarów kratowych Zakres: do 100 kN Metoda ścinania PN-EN 10080 Stal zbrojeniowa E Odpornosc na scinanie polaczenia zgrzewanego dzwigarow kratowych Zakres: do 100 kN Metoda scinania PN-EN 10080","categories":["materials"],"row_index":721,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Reinforcing steel E Shear resistance of the welded joint of lattice girders Range: up to 100 kN Shear method PN-EN 10080","search_zh":"配筋用钢 E PN-EN 10080","test_object_zh":"配筋用钢 E"},{"_id":"6a5a55f19af9f73f382511e6","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stal zbrojeniowa E","test_object_en":"Reinforcing steel E","methodology":"Pomiar wielkości geometrycznych i określenie względnego pola powierzchni żeber stali do zbrojenia betonu Zakres średnic: do 40 mm Metoda pomiaru bezpośredniego","methodology_en":"Measurement of geometric quantities and determination of the relative rib area of steel for the reinforcement of concrete Diameter range: up to 40 mm Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pomiar wielkości geometrycznych i określenie względnego pola powierzchni żeber stali do zbrojenia betonu Zakres średnic: do 40 mm Metoda pomiaru bezpośredniego","reference":"PN-EN ISO 15630-3 PN-EN ISO 15630 1","norm_bases":["PN-EN ISO 15630-3 PN-EN ISO 15630 1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stal zbrojeniowa E Pomiar wielkości geometrycznych i określenie względnego pola powierzchni żeber stali do zbrojenia betonu Zakres średnic: do 40 mm Metoda pomiaru bezpośredniego PN-EN ISO 15630-3 PN-EN ISO 15630 1 Stal zbrojeniowa E Pomiar wielkosci geometrycznych i okreslenie wzglednego pola powierzchni zeber stali do zbrojenia betonu Zakres srednic: do 40 mm Metoda pomiaru bezposredniego PN-EN ISO 15630-3 PN-EN ISO 15630 1","categories":["materials","construction"],"row_index":722,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Reinforcing steel E Measurement of geometric quantities and determination of the relative rib area of steel for the reinforcement of concrete Diameter range: up to 40 mm Direct measurement method PN-EN ISO 15630-3 PN-EN ISO 15630 1","search_zh":"配筋用钢 E PN-EN ISO 15630-3 PN-EN ISO 15630 1","test_object_zh":"配筋用钢 E"},{"_id":"6a5a55f19af9f73f382511e7","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stal zbrojeniowa E","test_object_en":"Reinforcing steel E","methodology":"Przyczepność stali zbrojeniowej żebrowanej i wgniatanej próba wyciągania Zakres średnic: do 20 mm Metoda wyciągania","methodology_en":"Bond of ribbed and indented reinforcing steel pull-out test Diameter range: up to 20 mm Pull-out method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przyczepność stali zbrojeniowej żebrowanej i wgniatanej próba wyciągania Zakres średnic: do 20 mm Metoda wyciągania","reference":"PN-EN 10080","norm_bases":["PN-EN 10080"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stal zbrojeniowa E Przyczepność stali zbrojeniowej żebrowanej i wgniatanej próba wyciągania Zakres średnic: do 20 mm Metoda wyciągania PN-EN 10080 Stal zbrojeniowa E Przyczepnosc stali zbrojeniowej zebrowanej i wgniatanej proba wyciagania Zakres srednic: do 20 mm Metoda wyciagania PN-EN 10080","categories":["materials"],"row_index":723,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Reinforcing steel E Bond of ribbed and indented reinforcing steel pull-out test Diameter range: up to 20 mm Pull-out method PN-EN 10080","search_zh":"配筋用钢 E PN-EN 10080","test_object_zh":"配筋用钢 E"},{"_id":"6a5a55f19af9f73f382511e8","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stal zbrojeniowa E","test_object_en":"Reinforcing steel E","methodology":"Zginanie i odginanie stali do zbrojenia betonu Zakres średnic: do 40 mm Metoda zginania / zginania z odginaniem","methodology_en":"Bending and rebending of steel for the reinforcement of concrete Diameter range: up to 40 mm Bend / rebend method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zginanie i odginanie stali do zbrojenia betonu Zakres średnic: do 40 mm Metoda zginania / zginania z odginaniem","reference":"PN-EN ISO 7438 PN-EN ISO 15630-1 PN-EN ISO 15630-2","norm_bases":["PN-EN ISO 7438 PN-EN ISO 15630-1 PN-EN ISO 15630-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stal zbrojeniowa E Zginanie i odginanie stali do zbrojenia betonu Zakres średnic: do 40 mm Metoda zginania / zginania z odginaniem PN-EN ISO 7438 PN-EN ISO 15630-1 PN-EN ISO 15630-2 Stal zbrojeniowa E Zginanie i odginanie stali do zbrojenia betonu Zakres srednic: do 40 mm Metoda zginania / zginania z odginaniem PN-EN ISO 7438 PN-EN ISO 15630-1 PN-EN ISO 15630-2","categories":["materials","construction"],"row_index":724,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Reinforcing steel E Bending and rebending of steel for the reinforcement of concrete Diameter range: up to 40 mm Bend / rebend method PN-EN ISO 7438 PN-EN ISO 15630-1 PN-EN ISO 15630-2","search_zh":"配筋用钢 E PN-EN ISO 7438 PN-EN ISO 15630-1 PN-EN ISO 15630-2","test_object_zh":"配筋用钢 E"},{"_id":"6a5a55f19af9f73f382511e9","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stal, stopy metali, elementy stalowe E","test_object_en":"Steel, metal alloys, steel components E","methodology":"Statyczna próba rozciągania Wytrzymałość i odkształcalność Zakres: do 1000 kN Metoda rozciągania","methodology_en":"Static tensile test Strength and deformability Range: up to 1000 kN Tensile method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Statyczna próba rozciągania Wytrzymałość i odkształcalność Zakres: do 1000 kN Metoda rozciągania","reference":"PN-EN ISO 15630-2 PN-EN ISO 15630-3 PN-EN ISO 15630-1 PN-EN ISO 6892-1","norm_bases":["PN-EN ISO 15630-2 PN-EN ISO 15630-3 PN-EN ISO 15630-1 PN-EN ISO 6892-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stal, stopy metali, elementy stalowe E Statyczna próba rozciągania Wytrzymałość i odkształcalność Zakres: do 1000 kN Metoda rozciągania PN-EN ISO 15630-2 PN-EN ISO 15630-3 PN-EN ISO 15630-1 PN-EN ISO 6892-1 Stal, stopy metali, elementy stalowe E Statyczna proba rozciagania Wytrzymalosc i odksztalcalnosc Zakres: do 1000 kN Metoda rozciagania PN-EN ISO 15630-2 PN-EN ISO 15630-3 PN-EN ISO 15630-1 PN-EN ISO 6892-1","categories":["materials"],"row_index":725,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Steel, metal alloys, steel components E Static tensile test Strength and deformability Range: up to 1000 kN Tensile method PN-EN ISO 15630-2 PN-EN ISO 15630-3 PN-EN ISO 15630-1 PN-EN ISO 6892-1","search_zh":"钢、合金、钢构件 E PN-EN ISO 15630-2 PN-EN ISO 15630-3 PN-EN ISO 15630-1 PN-EN ISO 6892-1","test_object_zh":"钢、合金、钢构件 E"},{"_id":"6a5a55f19af9f73f382511ea","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stal, stopy metali, elementy stalowe E","test_object_en":"Steel, metal alloys, steel components E","methodology":"Technologiczna próba zginania Zakres średnic stempli: (3 - 310) mm Metoda zginania","methodology_en":"Technological bend test Range of former diameters: (3 - 310) mm Bending method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Technologiczna próba zginania Zakres średnic stempli: (3 - 310) mm Metoda zginania","reference":"PN-EN ISO 7438","norm_bases":["PN-EN ISO 7438"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stal, stopy metali, elementy stalowe E Technologiczna próba zginania Zakres średnic stempli: (3 - 310) mm Metoda zginania PN-EN ISO 7438 Stal, stopy metali, elementy stalowe E Technologiczna proba zginania Zakres srednic stempli: (3 - 310) mm Metoda zginania PN-EN ISO 7438","categories":["materials"],"row_index":726,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Steel, metal alloys, steel components E Technological bend test Range of former diameters: (3 - 310) mm Bending method PN-EN ISO 7438","search_zh":"钢、合金、钢构件 E PN-EN ISO 7438","test_object_zh":"钢、合金、钢构件 E"},{"_id":"6a5a55f19af9f73f382511eb","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stal, stopy metali, elementy stalowe E","test_object_en":"Steel, metal alloys, steel components E","methodology":"Twardość Metoda Brinella Zakres: HBS 1/5 - 10/250 HBW 2,5","methodology_en":"Hardness Brinell method Range: HBS 1/5 - 10/250 HBW 2,5","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Twardość Metoda Brinella Zakres: HBS 1/5 - 10/250 HBW 2,5","reference":"PN-EN ISO 6506-1","norm_bases":["PN-EN ISO 6506-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stal, stopy metali, elementy stalowe E Twardość Metoda Brinella Zakres: HBS 1/5 - 10/250 HBW 2,5 PN-EN ISO 6506-1 Stal, stopy metali, elementy stalowe E Twardosc Metoda Brinella Zakres: HBS 1/5 - 10/250 HBW 2,5 PN-EN ISO 6506-1","categories":["materials"],"row_index":727,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Steel, metal alloys, steel components E Hardness Brinell method Range: HBS 1/5 - 10/250 HBW 2,5 PN-EN ISO 6506-1","search_zh":"钢、合金、钢构件 E PN-EN ISO 6506-1","test_object_zh":"钢、合金、钢构件 E"},{"_id":"6a5a55f19af9f73f382511ec","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stropowe belki żelbetowe E","test_object_en":"Reinforced concrete floor beams E","methodology":"Wytrzymałość Zakres: do 200 kN Próba zginania i ścinania","methodology_en":"Strength Range: up to 200 kN Bending and shear test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość Zakres: do 200 kN Próba zginania i ścinania","reference":"PN-EN 15037-1","norm_bases":["PN-EN 15037-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stropowe belki żelbetowe E Wytrzymałość Zakres: do 200 kN Próba zginania i ścinania PN-EN 15037-1 Stropowe belki zelbetowe E Wytrzymalosc Zakres: do 200 kN Proba zginania i scinania PN-EN 15037-1","categories":["other"],"row_index":728,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Reinforced concrete floor beams E Strength Range: up to 200 kN Bending and shear test PN-EN 15037-1"},{"_id":"6a5a55f19af9f73f382511ed","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Sufity podwieszane E","test_object_en":"Suspended ceilings E","methodology":"Nośność elementów rusztu","methodology_en":"Load-bearing capacity of grid elements","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność elementów rusztu","reference":"PN-EN 13964 „N”","norm_bases":["PN-EN 13964 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Sufity podwieszane E Nośność elementów rusztu PN-EN 13964 „N” Sufity podwieszane E Nosnosc elementow rusztu PN-EN 13964 „N”","categories":["other"],"row_index":729,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Suspended ceilings E Load-bearing capacity of grid elements PN-EN 13964 „N”","search_zh":"吊顶 E PN-EN 13964 „N”","test_object_zh":"吊顶 E"},{"_id":"6a5a55f19af9f73f382511ee","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Sufity podwieszane E","test_object_en":"Suspended ceilings E","methodology":"Odporność kształtowników rusztu na zginanie","methodology_en":"Bending resistance of grid profiles","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność kształtowników rusztu na zginanie","reference":"PN-EN 13964 „N”","norm_bases":["PN-EN 13964 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Sufity podwieszane E Odporność kształtowników rusztu na zginanie PN-EN 13964 „N” Sufity podwieszane E Odpornosc ksztaltownikow rusztu na zginanie PN-EN 13964 „N”","categories":["other"],"row_index":730,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Suspended ceilings E Bending resistance of grid profiles PN-EN 13964 „N”","search_zh":"吊顶 E PN-EN 13964 „N”","test_object_zh":"吊顶 E"},{"_id":"6a5a55f19af9f73f382511ef","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Sufity podwieszane E","test_object_en":"Suspended ceilings E","methodology":"Wymiary geometryczne liniowe","methodology_en":"Linear geometric dimensions","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary geometryczne liniowe","reference":"PN-EN 13964 „N”","norm_bases":["PN-EN 13964 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Sufity podwieszane E Wymiary geometryczne liniowe PN-EN 13964 „N” Sufity podwieszane E Wymiary geometryczne liniowe PN-EN 13964 „N”","categories":["other"],"row_index":731,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Suspended ceilings E Linear geometric dimensions PN-EN 13964 „N”","methodology_zh":"几何线性尺寸","search_zh":"吊顶 E 几何线性尺寸 PN-EN 13964 „N”","test_object_zh":"吊顶 E"},{"_id":"6a5a55f19af9f73f382511f0","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Włókna do betonu E","test_object_en":"Fibres for concrete E","methodology":"Wytrzymałość na rozciąganie i moduł sprężystości przy rozciąganiu Zakres: (0,1 - 10) kN Metoda rozciągania","methodology_en":"Tensile strength and tensile modulus of elasticity Range: (0,1 - 10) kN Tensile method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na rozciąganie i moduł sprężystości przy rozciąganiu Zakres: (0,1 - 10) kN Metoda rozciągania","reference":"PN-EN 14889-2 „N”","norm_bases":["PN-EN 14889-2 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Włókna do betonu E Wytrzymałość na rozciąganie i moduł sprężystości przy rozciąganiu Zakres: (0,1 - 10) kN Metoda rozciągania PN-EN 14889-2 „N” Wlokna do betonu E Wytrzymalosc na rozciaganie i modul sprezystosci przy rozciaganiu Zakres: (0,1 - 10) kN Metoda rozciagania PN-EN 14889-2 „N”","categories":["construction"],"row_index":732,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fibres for concrete E Tensile strength and tensile modulus of elasticity Range: (0,1 - 10) kN Tensile method PN-EN 14889-2 „N”"},{"_id":"6a5a55f19af9f73f382511f1","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wsporniki do murów E","test_object_en":"Wall brackets E","methodology":"Nośność oraz charakterystyki obciążenie-ugięcia Zakres: do 200 kN Próba zginania","methodology_en":"Load-bearing capacity and load-deflection characteristics Range: up to 200 kN Bending test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność oraz charakterystyki obciążenie-ugięcia Zakres: do 200 kN Próba zginania","reference":"PN-EN 846-10 „N”","norm_bases":["PN-EN 846-10 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wsporniki do murów E Nośność oraz charakterystyki obciążenie-ugięcia Zakres: do 200 kN Próba zginania PN-EN 846-10 „N” Wsporniki do murow E Nosnosc oraz charakterystyki obciazenie-ugiecia Zakres: do 200 kN Proba zginania PN-EN 846-10 „N”","categories":["other"],"row_index":733,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wall brackets E Load-bearing capacity and load-deflection characteristics Range: up to 200 kN Bending test PN-EN 846-10 „N”"},{"_id":"6a5a55f19af9f73f382511f2","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zaprawy budowlane E","test_object_en":"Building mortars E","methodology":"Absorpcja Zakres: do 40% Metoda wagowa","methodology_en":"Absorption Range: up to 40% Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Absorpcja Zakres: do 40% Metoda wagowa","reference":"PN-EN 1015-18","norm_bases":["PN-EN 1015-18"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy budowlane E Absorpcja Zakres: do 40% Metoda wagowa PN-EN 1015-18 Zaprawy budowlane E Absorpcja Zakres: do 40% Metoda wagowa PN-EN 1015-18","categories":["construction"],"row_index":734,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building mortars E Absorption Range: up to 40% Gravimetric method PN-EN 1015-18","search_zh":"建筑砂浆 E PN-EN 1015-18","test_object_zh":"建筑砂浆 E"},{"_id":"6a5a55f19af9f73f382511f3","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zaprawy budowlane E","test_object_en":"Building mortars E","methodology":"Konsystencja świeżej zaprawy Metoda stolika rozpływowego","methodology_en":"Consistency of fresh mortar Flow table method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Konsystencja świeżej zaprawy Metoda stolika rozpływowego","reference":"PN-EN 1015-3","norm_bases":["PN-EN 1015-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy budowlane E Konsystencja świeżej zaprawy Metoda stolika rozpływowego PN-EN 1015-3 Zaprawy budowlane E Konsystencja swiezej zaprawy Metoda stolika rozplywowego PN-EN 1015-3","categories":["construction"],"row_index":735,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building mortars E Consistency of fresh mortar Flow table method PN-EN 1015-3","search_zh":"建筑砂浆 E PN-EN 1015-3","test_object_zh":"建筑砂浆 E"},{"_id":"6a5a55f19af9f73f382511f4","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zaprawy budowlane E","test_object_en":"Building mortars E","methodology":"Moduł sprężystości zapraw przy ściskaniu Zakres sił: do 100 kN Próba ściskania","methodology_en":"Modulus of elasticity of mortars in compression Force range: up to 100 kN Compression test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moduł sprężystości zapraw przy ściskaniu Zakres sił: do 100 kN Próba ściskania","reference":"PN-EN 13412","norm_bases":["PN-EN 13412"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy budowlane E Moduł sprężystości zapraw przy ściskaniu Zakres sił: do 100 kN Próba ściskania PN-EN 13412 Zaprawy budowlane E Modul sprezystosci zapraw przy sciskaniu Zakres sil: do 100 kN Proba sciskania PN-EN 13412","categories":["construction"],"row_index":736,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building mortars E Modulus of elasticity of mortars in compression Force range: up to 100 kN Compression test PN-EN 13412","search_zh":"建筑砂浆 E PN-EN 13412","test_object_zh":"建筑砂浆 E"},{"_id":"6a5a55f19af9f73f382511f5","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zaprawy budowlane E","test_object_en":"Building mortars E","methodology":"Przyczepność Zakres: do 10 MPa Metoda odrywania","methodology_en":"Adhesion Range: up to 10 MPa Pull-off method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przyczepność Zakres: do 10 MPa Metoda odrywania","reference":"PN-EN 1015-12","norm_bases":["PN-EN 1015-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy budowlane E Przyczepność Zakres: do 10 MPa Metoda odrywania PN-EN 1015-12 Zaprawy budowlane E Przyczepnosc Zakres: do 10 MPa Metoda odrywania PN-EN 1015-12","categories":["construction"],"row_index":737,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building mortars E Adhesion Range: up to 10 MPa Pull-off method PN-EN 1015-12","search_zh":"建筑砂浆 E PN-EN 1015-12","test_object_zh":"建筑砂浆 E"},{"_id":"6a5a55f19af9f73f382511f6","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zaprawy budowlane E","test_object_en":"Building mortars E","methodology":"Wytrzymałość na ściskanie Zakres: do 200 kN Próba ściskania","methodology_en":"Compressive strength Range: up to 200 kN Compression test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie Zakres: do 200 kN Próba ściskania","reference":"PN-EN 1015-11","norm_bases":["PN-EN 1015-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy budowlane E Wytrzymałość na ściskanie Zakres: do 200 kN Próba ściskania PN-EN 1015-11 Zaprawy budowlane E Wytrzymalosc na sciskanie Zakres: do 200 kN Proba sciskania PN-EN 1015-11","categories":["construction"],"row_index":738,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building mortars E Compressive strength Range: up to 200 kN Compression test PN-EN 1015-11","search_zh":"建筑砂浆 E PN-EN 1015-11","test_object_zh":"建筑砂浆 E"},{"_id":"6a5a55f19af9f73f382511f7","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zaprawy budowlane E","test_object_en":"Building mortars E","methodology":"Wytrzymałość na zginanie Zakres: do 200 kN Próba zginania","methodology_en":"Flexural strength Range: up to 200 kN Bending test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na zginanie Zakres: do 200 kN Próba zginania","reference":"PN-EN 1015-11","norm_bases":["PN-EN 1015-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy budowlane E Wytrzymałość na zginanie Zakres: do 200 kN Próba zginania PN-EN 1015-11 Zaprawy budowlane E Wytrzymalosc na zginanie Zakres: do 200 kN Proba zginania PN-EN 1015-11","categories":["construction"],"row_index":739,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building mortars E Flexural strength Range: up to 200 kN Bending test PN-EN 1015-11","search_zh":"建筑砂浆 E PN-EN 1015-11","test_object_zh":"建筑砂浆 E"},{"_id":"6a5a55f19af9f73f382511f8","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Złącza klejone do konstrukcji drewnianych Konstrukcje drewniane – drewno konstrukcyjne lite i klejone warstwowo E)","test_object_en":"Bonded joints for timber structures Timber structures – solid structural timber and glued laminated timber E)","methodology":"Wytrzymałość na zginanie Zakres: (1 - 400) kN Próba zginania","methodology_en":"Flexural strength Range: (1 - 400) kN Bending test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na zginanie Zakres: (1 - 400) kN Próba zginania","reference":"PN-EN 408 PN-EN 384","norm_bases":["PN-EN 408 PN-EN 384"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Złącza klejone do konstrukcji drewnianych Konstrukcje drewniane – drewno konstrukcyjne lite i klejone warstwowo E) Wytrzymałość na zginanie Zakres: (1 - 400) kN Próba zginania PN-EN 408 PN-EN 384 Zlacza klejone do konstrukcji drewnianych Konstrukcje drewniane – drewno konstrukcyjne lite i klejone warstwowo E) Wytrzymalosc na zginanie Zakres: (1 - 400) kN Proba zginania PN-EN 408 PN-EN 384","categories":["other"],"row_index":740,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Bonded joints for timber structures Timber structures – solid structural timber and glued laminated timber E) Flexural strength Range: (1 - 400) kN Bending test PN-EN 408 PN-EN 384"},{"_id":"6a5a55f19af9f73f382511f9","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Złącza klejone do konstrukcji drewnianych Konstrukcje drewniane – drewno konstrukcyjne lite i klejone warstwowo E)","test_object_en":"Bonded joints for timber structures Timber structures – solid structural timber and glued laminated timber E)","methodology":"Moduł sprężystości wzdłuż włókien przy zginaniu Zakres: (1 - 400) kN","methodology_en":"Modulus of elasticity parallel to the grain in bending Range: (1 - 400) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moduł sprężystości wzdłuż włókien przy zginaniu Zakres: (1 - 400) kN","reference":"PN-EN 408 PN-EN 384","norm_bases":["PN-EN 408 PN-EN 384"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Złącza klejone do konstrukcji drewnianych Konstrukcje drewniane – drewno konstrukcyjne lite i klejone warstwowo E) Moduł sprężystości wzdłuż włókien przy zginaniu Zakres: (1 - 400) kN PN-EN 408 PN-EN 384 Zlacza klejone do konstrukcji drewnianych Konstrukcje drewniane – drewno konstrukcyjne lite i klejone warstwowo E) Modul sprezystosci wzdluz wlokien przy zginaniu Zakres: (1 - 400) kN PN-EN 408 PN-EN 384","categories":["other"],"row_index":741,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Bonded joints for timber structures Timber structures – solid structural timber and glued laminated timber E) Modulus of elasticity parallel to the grain in bending Range: (1 - 400) kN PN-EN 408 PN-EN 384"},{"_id":"6a5a55f19af9f73f382511fa","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zwieńczenia wpustów i studzienek kanalizacyjnych do nawierzchni dla ruchu pieszego i kołowego E","test_object_en":"Gully tops and manhole tops for vehicular and pedestrian areas E","methodology":"Nośność i odkształcenie trwałe Zakres sił: do 5 MN, klas A15 - F90 Próba ściskania","methodology_en":"Load-bearing capacity and permanent deformation Force range: up to 5 MN, classes A15 - F90 Compression test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność i odkształcenie trwałe Zakres sił: do 5 MN, klas A15 - F90 Próba ściskania","reference":"PN-EN 124-1","norm_bases":["PN-EN 124-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zwieńczenia wpustów i studzienek kanalizacyjnych do nawierzchni dla ruchu pieszego i kołowego E Nośność i odkształcenie trwałe Zakres sił: do 5 MN, klas A15 - F90 Próba ściskania PN-EN 124-1 Zwienczenia wpustow i studzienek kanalizacyjnych do nawierzchni dla ruchu pieszego i kolowego E Nosnosc i odksztalcenie trwale Zakres sil: do 5 MN, klas A15 - F90 Proba sciskania PN-EN 124-1","categories":["other"],"row_index":742,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gully tops and manhole tops for vehicular and pedestrian areas E Load-bearing capacity and permanent deformation Force range: up to 5 MN, classes A15 - F90 Compression test PN-EN 124-1","search_zh":"人行与车行路面用雨水口与检查井盖座 E PN-EN 124-1","test_object_zh":"人行与车行路面用雨水口与检查井盖座 E"},{"_id":"6a5a55f19af9f73f382511fb","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zwieńczenia wpustów i studzienek kanalizacyjnych do nawierzchni dla ruchu pieszego i kołowego E","test_object_en":"Gully tops and manhole tops for vehicular and pedestrian areas E","methodology":"Odporność na poślizg: - stan powierzchni betonowej - wysokość wzoru h, - pole powierzchni wzoru An - wymiary szczelin krat","methodology_en":"Slip resistance: - condition of the concrete surface - pattern height h, - pattern surface area An - dimensions of grating slots","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na poślizg: - stan powierzchni betonowej - wysokość wzoru h, - pole powierzchni wzoru An - wymiary szczelin krat","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zwieńczenia wpustów i studzienek kanalizacyjnych do nawierzchni dla ruchu pieszego i kołowego E Odporność na poślizg: - stan powierzchni betonowej - wysokość wzoru h, - pole powierzchni wzoru An - wymiary szczelin krat Zwienczenia wpustow i studzienek kanalizacyjnych do nawierzchni dla ruchu pieszego i kolowego E Odpornosc na poslizg: - stan powierzchni betonowej - wysokosc wzoru h, - pole powierzchni wzoru An - wymiary szczelin krat","categories":["construction"],"row_index":743,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gully tops and manhole tops for vehicular and pedestrian areas E Slip resistance: - condition of the concrete surface - pattern height h, - pattern surface area An - dimensions of grating slots","search_zh":"人行与车行路面用雨水口与检查井盖座 E","test_object_zh":"人行与车行路面用雨水口与检查井盖座 E"},{"_id":"6a5a55f19af9f73f382511fc","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zwieńczenia wpustów i studzienek kanalizacyjnych do nawierzchni dla ruchu pieszego i kołowego E","test_object_en":"Gully tops and manhole tops for vehicular and pedestrian areas E","methodology":"Powierzchnia nośna","methodology_en":"Bearing area","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Powierzchnia nośna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zwieńczenia wpustów i studzienek kanalizacyjnych do nawierzchni dla ruchu pieszego i kołowego E Powierzchnia nośna Zwienczenia wpustow i studzienek kanalizacyjnych do nawierzchni dla ruchu pieszego i kolowego E Powierzchnia nosna","categories":["other"],"row_index":744,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gully tops and manhole tops for vehicular and pedestrian areas E Bearing area","search_zh":"人行与车行路面用雨水口与检查井盖座 E","test_object_zh":"人行与车行路面用雨水口与检查井盖座 E"},{"_id":"6a5a55f19af9f73f382511fd","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zwieńczenia wpustów i studzienek kanalizacyjnych do nawierzchni dla ruchu pieszego i kołowego E","test_object_en":"Gully tops and manhole tops for vehicular and pedestrian areas E","methodology":"Zabezpieczenie pokrywy/kraty w korpusie: - masa pokrywy/kraty na jednostkę powierzchni - przemieszczenie h pokrywy/kraty odpowiadające sile Fv","methodology_en":"Securing of the cover/grating within the frame: - mass of the cover/grating per unit area - displacement h of the cover/grating corresponding to the force Fv","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zabezpieczenie pokrywy/kraty w korpusie: - masa pokrywy/kraty na jednostkę powierzchni - przemieszczenie h pokrywy/kraty odpowiadające sile Fv","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zwieńczenia wpustów i studzienek kanalizacyjnych do nawierzchni dla ruchu pieszego i kołowego E Zabezpieczenie pokrywy/kraty w korpusie: - masa pokrywy/kraty na jednostkę powierzchni - przemieszczenie h pokrywy/kraty odpowiadające sile Fv Zwienczenia wpustow i studzienek kanalizacyjnych do nawierzchni dla ruchu pieszego i kolowego E Zabezpieczenie pokrywy/kraty w korpusie: - masa pokrywy/kraty na jednostke powierzchni - przemieszczenie h pokrywy/kraty odpowiadajace sile Fv","categories":["other"],"row_index":745,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gully tops and manhole tops for vehicular and pedestrian areas E Securing of the cover/grating within the frame: - mass of the cover/grating per unit area - displacement h of the cover/grating corresponding to the force Fv","search_zh":"人行与车行路面用雨水口与检查井盖座 E","test_object_zh":"人行与车行路面用雨水口与检查井盖座 E"},{"_id":"6a5a55f19af9f73f382511fe","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Gwoździe i wkręty konstrukcyjne","test_object_en":"Structural nails and screws","methodology":"Opór charakterystyczny przy wkręcaniu Zakres momentów: od (1- 30) Nm zakotwienie do 50 mm Próba wkręcania","methodology_en":"Characteristic screw-in resistance Torque range: from (1- 30) Nm anchorage up to 50 mm Screw-in test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Opór charakterystyczny przy wkręcaniu Zakres momentów: od (1- 30) Nm zakotwienie do 50 mm Próba wkręcania","reference":"PN-EN 15737:2009 „N” PN-EN ISO 10666:2002 PN-EN 14592:2022-09","norm_bases":["PN-EN 15737:2009 „N” PN-EN ISO 10666:2002 PN-EN 14592:2022-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gwoździe i wkręty konstrukcyjne Opór charakterystyczny przy wkręcaniu Zakres momentów: od (1- 30) Nm zakotwienie do 50 mm Próba wkręcania PN-EN 15737:2009 „N” PN-EN ISO 10666:2002 PN-EN 14592:2022-09 Gwozdzie i wkrety konstrukcyjne Opor charakterystyczny przy wkrecaniu Zakres momentow: od (1- 30) Nm zakotwienie do 50 mm Proba wkrecania PN-EN 15737:2009 „N” PN-EN ISO 10666:2002 PN-EN 14592:2022-09","categories":["other"],"row_index":746,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Structural nails and screws Characteristic screw-in resistance Torque range: from (1- 30) Nm anchorage up to 50 mm Screw-in test PN-EN 15737:2009 „N” PN-EN ISO 10666:2002 PN-EN 14592:2022-09"},{"_id":"6a5a55f19af9f73f382511ff","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Gwoździe i wkręty konstrukcyjne","test_object_en":"Structural nails and screws","methodology":"Wymiary geometryczne Zakres: do 400 mm","methodology_en":"Geometric dimensions Range: up to 400 mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary geometryczne Zakres: do 400 mm","reference":"LOK-B00/3/03-2018 | PN-EN 14592:2022-09","norm_bases":["LOK-B00/3/03-2018","PN-EN 14592:2022-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gwoździe i wkręty konstrukcyjne Wymiary geometryczne Zakres: do 400 mm LOK-B00/3/03-2018 | PN-EN 14592:2022-09 Gwozdzie i wkrety konstrukcyjne Wymiary geometryczne Zakres: do 400 mm LOK-B00/3/03-2018 | PN-EN 14592:2022-09","categories":["other"],"row_index":747,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Structural nails and screws Geometric dimensions Range: up to 400 mm LOK-B00/3/03-2018 | PN-EN 14592:2022-09"},{"_id":"6a5a55f19af9f73f38251200","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Łączniki do mocowania termoizolacji","test_object_en":"Fasteners for fixing thermal insulation","methodology":"Wymiary geometryczne liniowe Zakres: do 400 mm","methodology_en":"Linear geometrical dimensions Range: up to 400 mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary geometryczne liniowe Zakres: do 400 mm","reference":"LOK-B00/3/03-2018","norm_bases":["LOK-B00/3/03-2018"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łączniki do mocowania termoizolacji Wymiary geometryczne liniowe Zakres: do 400 mm LOK-B00/3/03-2018 Laczniki do mocowania termoizolacji Wymiary geometryczne liniowe Zakres: do 400 mm LOK-B00/3/03-2018","categories":["other"],"row_index":748,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fasteners for fixing thermal insulation Linear geometrical dimensions Range: up to 400 mm LOK-B00/3/03-2018","methodology_zh":"几何线性尺寸 范围：至 400 mm","search_zh":"几何线性尺寸 范围：至 400 mm LOK-B00/3/03-2018"},{"_id":"6a5a55f19af9f73f38251201","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Łączniki do mocowania termoizolacji","test_object_en":"Fasteners for fixing thermal insulation","methodology":"Sztywność talerzyka Zakres: (0,01 - 5) kN Próba sztywności","methodology_en":"Disc stiffness Range: (0,01 - 5) kN Stiffness test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sztywność talerzyka Zakres: (0,01 - 5) kN Próba sztywności","reference":"TR026:2016","norm_bases":["TR026:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łączniki do mocowania termoizolacji Sztywność talerzyka Zakres: (0,01 - 5) kN Próba sztywności TR026:2016 Laczniki do mocowania termoizolacji Sztywnosc talerzyka Zakres: (0,01 - 5) kN Proba sztywnosci TR026:2016","categories":["other"],"row_index":749,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fasteners for fixing thermal insulation Disc stiffness Range: (0,01 - 5) kN Stiffness test TR026:2016"},{"_id":"6a5a55f19af9f73f38251202","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Łączniki do mocowania elementów cienkościennych i warstwowych","test_object_en":"Fasteners for fixing thin-walled and sandwich elements","methodology":"Nośność na ścinanie Zakres: (0,5 - 50) kN Próba ścinania","methodology_en":"Shear load capacity Range: (0,5 - 50) kN Shear test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność na ścinanie Zakres: (0,5 - 50) kN Próba ścinania","reference":"LOK-B07/4/03-2018","norm_bases":["LOK-B07/4/03-2018"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łączniki do mocowania elementów cienkościennych i warstwowych Nośność na ścinanie Zakres: (0,5 - 50) kN Próba ścinania LOK-B07/4/03-2018 Laczniki do mocowania elementow cienkosciennych i warstwowych Nosnosc na scinanie Zakres: (0,5 - 50) kN Proba scinania LOK-B07/4/03-2018","categories":["other"],"row_index":750,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fasteners for fixing thin-walled and sandwich elements Shear load capacity Range: (0,5 - 50) kN Shear test LOK-B07/4/03-2018"},{"_id":"6a5a55f19af9f73f38251203","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Łączniki do mocowania elementów cienkościennych i warstwowych","test_object_en":"Fasteners for fixing thin-walled and sandwich elements","methodology":"Wymiary geometryczne liniowe Zakres: do 400 mm","methodology_en":"Linear geometrical dimensions Range: up to 400 mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary geometryczne liniowe Zakres: do 400 mm","reference":"LOK-B00/3/03-2018","norm_bases":["LOK-B00/3/03-2018"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łączniki do mocowania elementów cienkościennych i warstwowych Wymiary geometryczne liniowe Zakres: do 400 mm LOK-B00/3/03-2018 Laczniki do mocowania elementow cienkosciennych i warstwowych Wymiary geometryczne liniowe Zakres: do 400 mm LOK-B00/3/03-2018","categories":["other"],"row_index":751,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fasteners for fixing thin-walled and sandwich elements Linear geometrical dimensions Range: up to 400 mm LOK-B00/3/03-2018","methodology_zh":"几何线性尺寸 范围：至 400 mm","search_zh":"几何线性尺寸 范围：至 400 mm LOK-B00/3/03-2018"},{"_id":"6a5a55f19af9f73f38251204","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Łączniki metalowe: rozporowe, wbijane, wkręcane","test_object_en":"Metal fasteners: expansion, drive-in, screw-in","methodology":"Wymiary geometryczne liniowe Zakres: (0,1 - 1000) mm","methodology_en":"Linear geometric dimensions Range: (0,1 - 1000) mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary geometryczne liniowe Zakres: (0,1 - 1000) mm","reference":"LOK-B00/3/03-2018","norm_bases":["LOK-B00/3/03-2018"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łączniki metalowe: rozporowe, wbijane, wkręcane Wymiary geometryczne liniowe Zakres: (0,1 - 1000) mm LOK-B00/3/03-2018 Laczniki metalowe: rozporowe, wbijane, wkrecane Wymiary geometryczne liniowe Zakres: (0,1 - 1000) mm LOK-B00/3/03-2018","categories":["materials"],"row_index":752,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Metal fasteners: expansion, drive-in, screw-in Linear geometric dimensions Range: (0,1 - 1000) mm LOK-B00/3/03-2018"},{"_id":"6a5a55f19af9f73f38251205","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Łączniki metalowe: wklejane","test_object_en":"Metal fasteners: bonded","methodology":"Wymiary geometryczne liniowe Zakres: do 400 mm","methodology_en":"Linear geometrical dimensions Range: up to 400 mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary geometryczne liniowe Zakres: do 400 mm","reference":"LOK-B00/3/03-2018","norm_bases":["LOK-B00/3/03-2018"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łączniki metalowe: wklejane Wymiary geometryczne liniowe Zakres: do 400 mm LOK-B00/3/03-2018 Laczniki metalowe: wklejane Wymiary geometryczne liniowe Zakres: do 400 mm LOK-B00/3/03-2018","categories":["materials"],"row_index":753,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Metal fasteners: bonded Linear geometrical dimensions Range: up to 400 mm LOK-B00/3/03-2018","methodology_zh":"几何线性尺寸 范围：至 400 mm","search_zh":"几何线性尺寸 范围：至 400 mm LOK-B00/3/03-2018"},{"_id":"6a5a55f19af9f73f38251206","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Łączniki metalowe: wklejane, osadzane","test_object_en":"Metal fasteners: bonded, embedded","methodology":"Nośność na ścinanie na ramieniu Zakres: do 100 kN Próba ścinania na ramieniu","methodology_en":"Shear load-bearing capacity with lever arm Range: up to 100 kN Shear test with lever arm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność na ścinanie na ramieniu Zakres: do 100 kN Próba ścinania na ramieniu","reference":"LOK-B10/2/03-2018","norm_bases":["LOK-B10/2/03-2018"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łączniki metalowe: wklejane, osadzane Nośność na ścinanie na ramieniu Zakres: do 100 kN Próba ścinania na ramieniu LOK-B10/2/03-2018 Laczniki metalowe: wklejane, osadzane Nosnosc na scinanie na ramieniu Zakres: do 100 kN Proba scinania na ramieniu LOK-B10/2/03-2018","categories":["materials","water"],"row_index":754,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Metal fasteners: bonded, embedded Shear load-bearing capacity with lever arm Range: up to 100 kN Shear test with lever arm LOK-B10/2/03-2018"},{"_id":"6a5a55f19af9f73f38251207","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stal","test_object_en":"Steel","methodology":"Grubość powłoki antykorozyjnej Zakres: do 45 µm","methodology_en":"Thickness of the anti-corrosion coating Range: up to 45 µm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Grubość powłoki antykorozyjnej Zakres: do 45 µm","reference":"LOK-B52/2/11-2018 | PN-EN ISO 3497:2004","norm_bases":["LOK-B52/2/11-2018","PN-EN ISO 3497:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stal Grubość powłoki antykorozyjnej Zakres: do 45 µm LOK-B52/2/11-2018 | PN-EN ISO 3497:2004 Stal Grubosc powloki antykorozyjnej Zakres: do 45 µm LOK-B52/2/11-2018 | PN-EN ISO 3497:2004","categories":["materials"],"row_index":755,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Steel Thickness of the anti-corrosion coating Range: up to 45 µm LOK-B52/2/11-2018 | PN-EN ISO 3497:2004","search_zh":"钢 LOK-B52/2/11-2018 | PN-EN ISO 3497:2004","test_object_zh":"钢"},{"_id":"6a5a55f19af9f73f38251208","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Ruszty i wieszaki oraz łączniki sufitów podwieszanych","test_object_en":"Grids, hangers and connectors of suspended ceilings","methodology":"Grubość powłoki cynkowej (badanie trwałości) Zakres: do 45 µm","methodology_en":"Thickness of the zinc coating (durability test) Range: up to 45 µm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Grubość powłoki cynkowej (badanie trwałości) Zakres: do 45 µm","reference":"LOK-B52/2/11-2018 | PN-EN ISO 3497:2004","norm_bases":["LOK-B52/2/11-2018","PN-EN ISO 3497:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ruszty i wieszaki oraz łączniki sufitów podwieszanych Grubość powłoki cynkowej (badanie trwałości) Zakres: do 45 µm LOK-B52/2/11-2018 | PN-EN ISO 3497:2004 Ruszty i wieszaki oraz laczniki sufitow podwieszanych Grubosc powloki cynkowej (badanie trwalosci) Zakres: do 45 µm LOK-B52/2/11-2018 | PN-EN ISO 3497:2004","categories":["other"],"row_index":756,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Grids, hangers and connectors of suspended ceilings Thickness of the zinc coating (durability test) Range: up to 45 µm LOK-B52/2/11-2018 | PN-EN ISO 3497:2004"},{"_id":"6a5a55f19af9f73f38251209","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"System mocowania rur","test_object_en":"Pipe fixing system","methodology":"Nośność obejm na obciążenie Zakres: (0,5 - 100) kN Próba rozciągania","methodology_en":"Load-bearing capacity of clamps under load Range: (0,5 - 100) kN Tensile test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność obejm na obciążenie Zakres: (0,5 - 100) kN Próba rozciągania","reference":"LOK-B11/1/03/2015","norm_bases":["LOK-B11/1/03/2015"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"System mocowania rur Nośność obejm na obciążenie Zakres: (0,5 - 100) kN Próba rozciągania LOK-B11/1/03/2015 System mocowania rur Nosnosc obejm na obciazenie Zakres: (0,5 - 100) kN Proba rozciagania LOK-B11/1/03/2015","categories":["other"],"row_index":757,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Pipe fixing system Load-bearing capacity of clamps under load Range: (0,5 - 100) kN Tensile test LOK-B11/1/03/2015"},{"_id":"6a5a55f19af9f73f3825120a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Trójwymiarowe łączniki stalowe","test_object_en":"Three-dimensional steel connectors","methodology":"Grubość powłoki cynkowej Zakres: (1 - 45) µm","methodology_en":"Thickness of the zinc coating Range: (1 - 45) µm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Grubość powłoki cynkowej Zakres: (1 - 45) µm","reference":"LOK-B52/2/11-2018 | PN-EN ISO 3497:2004","norm_bases":["LOK-B52/2/11-2018","PN-EN ISO 3497:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Trójwymiarowe łączniki stalowe Grubość powłoki cynkowej Zakres: (1 - 45) µm LOK-B52/2/11-2018 | PN-EN ISO 3497:2004 Trojwymiarowe laczniki stalowe Grubosc powloki cynkowej Zakres: (1 - 45) µm LOK-B52/2/11-2018 | PN-EN ISO 3497:2004","categories":["materials"],"row_index":758,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Three-dimensional steel connectors Thickness of the zinc coating Range: (1 - 45) µm LOK-B52/2/11-2018 | PN-EN ISO 3497:2004"},{"_id":"6a5a55f19af9f73f3825120b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Trójwymiarowe łączniki stalowe","test_object_en":"Three-dimensional steel connectors","methodology":"Nośność złączy Zakres: (0,1 - 400) kN Próba rozciągania z ścinaniem","methodology_en":"Load-bearing capacity of joints Range: (0,1 - 400) kN Tensile-shear test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność złączy Zakres: (0,1 - 400) kN Próba rozciągania z ścinaniem","reference":"PN-EN 26891:1997 + TR016:2002 PN-EN 26891:1997 + EAD 130186-00-0603","norm_bases":["PN-EN 26891:1997 + TR016:2002 PN-EN 26891:1997 + EAD 130186-00-0603"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Trójwymiarowe łączniki stalowe Nośność złączy Zakres: (0,1 - 400) kN Próba rozciągania z ścinaniem PN-EN 26891:1997 + TR016:2002 PN-EN 26891:1997 + EAD 130186-00-0603 Trojwymiarowe laczniki stalowe Nosnosc zlaczy Zakres: (0,1 - 400) kN Proba rozciagania z scinaniem PN-EN 26891:1997 + TR016:2002 PN-EN 26891:1997 + EAD 130186-00-0603","categories":["materials"],"row_index":759,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Three-dimensional steel connectors Load-bearing capacity of joints Range: (0,1 - 400) kN Tensile-shear test PN-EN 26891:1997 + TR016:2002 PN-EN 26891:1997 + EAD 130186-00-0603"},{"_id":"6a5a55f19af9f73f3825120c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Beton E","test_object_en":"Concrete E","methodology":"Gęstość Zakres: (1 - 60) kg Metoda wagowa","methodology_en":"Density Range: (1 - 60) kg Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Gęstość Zakres: (1 - 60) kg Metoda wagowa","reference":"PN-EN 12390-7","norm_bases":["PN-EN 12390-7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton E Gęstość Zakres: (1 - 60) kg Metoda wagowa PN-EN 12390-7 Beton E Gestosc Zakres: (1 - 60) kg Metoda wagowa PN-EN 12390-7","categories":["construction"],"row_index":760,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete E Density Range: (1 - 60) kg Gravimetric method PN-EN 12390-7","search_zh":"混凝土 E PN-EN 12390-7","test_object_zh":"混凝土 E"},{"_id":"6a5a55f19af9f73f3825120d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Beton E","test_object_en":"Concrete E","methodology":"Wytrzymałość na rozciąganie przy rozłupywaniu Zakres: (1 - 3000) kN Próba rozciągania","methodology_en":"Splitting tensile strength Range: (1 - 3000) kN Tensile test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na rozciąganie przy rozłupywaniu Zakres: (1 - 3000) kN Próba rozciągania","reference":"PN-EN 12390-6","norm_bases":["PN-EN 12390-6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton E Wytrzymałość na rozciąganie przy rozłupywaniu Zakres: (1 - 3000) kN Próba rozciągania PN-EN 12390-6 Beton E Wytrzymalosc na rozciaganie przy rozlupywaniu Zakres: (1 - 3000) kN Proba rozciagania PN-EN 12390-6","categories":["construction"],"row_index":761,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete E Splitting tensile strength Range: (1 - 3000) kN Tensile test PN-EN 12390-6","search_zh":"混凝土 E PN-EN 12390-6","test_object_zh":"混凝土 E"},{"_id":"6a5a55f19af9f73f3825120e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Beton E","test_object_en":"Concrete E","methodology":"Wytrzymałość na ściskanie Zakres: (1 - 3000) kN Próba ściskania","methodology_en":"Compressive strength Range: (1 - 3000) kN Compression test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie Zakres: (1 - 3000) kN Próba ściskania","reference":"PN-EN 12390-3 PN-EN 12504-1","norm_bases":["PN-EN 12390-3 PN-EN 12504-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton E Wytrzymałość na ściskanie Zakres: (1 - 3000) kN Próba ściskania PN-EN 12390-3 PN-EN 12504-1 Beton E Wytrzymalosc na sciskanie Zakres: (1 - 3000) kN Proba sciskania PN-EN 12390-3 PN-EN 12504-1","categories":["construction"],"row_index":762,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete E Compressive strength Range: (1 - 3000) kN Compression test PN-EN 12390-3 PN-EN 12504-1","search_zh":"混凝土 E PN-EN 12390-3 PN-EN 12504-1","test_object_zh":"混凝土 E"},{"_id":"6a5a55f19af9f73f3825120f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Beton E","test_object_en":"Concrete E","methodology":"Wytrzymałość na zginanie Zakres: (1 - 100) kN Próba zginania","methodology_en":"Bending strength Range: (1 - 100) kN Bending test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na zginanie Zakres: (1 - 100) kN Próba zginania","reference":"PN-EN 12390-5","norm_bases":["PN-EN 12390-5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton E Wytrzymałość na zginanie Zakres: (1 - 100) kN Próba zginania PN-EN 12390-5 Beton E Wytrzymalosc na zginanie Zakres: (1 - 100) kN Proba zginania PN-EN 12390-5","categories":["construction"],"row_index":763,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete E Bending strength Range: (1 - 100) kN Bending test PN-EN 12390-5","search_zh":"混凝土 E PN-EN 12390-5","test_object_zh":"混凝土 E"},{"_id":"6a5a55f19af9f73f38251210","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Betonowe kostki brukowe E","test_object_en":"Concrete paving blocks E","methodology":"Wytrzymałość na rozciąganie przy rozłupywaniu oraz obciążenie niszczące Zakres: (1 - 3000) kN Próba rozciągania","methodology_en":"Splitting tensile strength and failure load Range: (1 - 3000) kN Tensile test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na rozciąganie przy rozłupywaniu oraz obciążenie niszczące Zakres: (1 - 3000) kN Próba rozciągania","reference":"PN-EN 1338, Załącznik F","norm_bases":["PN-EN 1338, Załącznik F"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Betonowe kostki brukowe E Wytrzymałość na rozciąganie przy rozłupywaniu oraz obciążenie niszczące Zakres: (1 - 3000) kN Próba rozciągania PN-EN 1338, Załącznik F Betonowe kostki brukowe E Wytrzymalosc na rozciaganie przy rozlupywaniu oraz obciazenie niszczace Zakres: (1 - 3000) kN Proba rozciagania PN-EN 1338, Zalacznik F","categories":["construction"],"row_index":764,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete paving blocks E Splitting tensile strength and failure load Range: (1 - 3000) kN Tensile test PN-EN 1338, Załącznik F","search_zh":"混凝土路面砖 E PN-EN 1338, Załącznik F","test_object_zh":"混凝土路面砖 E"},{"_id":"6a5a55f19af9f73f38251211","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Betonowe płyty brukowe E","test_object_en":"Concrete paving flags E","methodology":"Wytrzymałość na zginanie oraz obciążenie niszczące Zakres: (1 - 100) kN Próba zginania","methodology_en":"Flexural strength and failure load Range: (1 - 100) kN Bending test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na zginanie oraz obciążenie niszczące Zakres: (1 - 100) kN Próba zginania","reference":"PN-EN 1339, Załącznik F","norm_bases":["PN-EN 1339, Załącznik F"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Betonowe płyty brukowe E Wytrzymałość na zginanie oraz obciążenie niszczące Zakres: (1 - 100) kN Próba zginania PN-EN 1339, Załącznik F Betonowe plyty brukowe E Wytrzymalosc na zginanie oraz obciazenie niszczace Zakres: (1 - 100) kN Proba zginania PN-EN 1339, Zalacznik F","categories":["construction"],"row_index":765,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete paving flags E Flexural strength and failure load Range: (1 - 100) kN Bending test PN-EN 1339, Załącznik F","search_zh":"混凝土铺路板 E PN-EN 1339, Załącznik F","test_object_zh":"混凝土铺路板 E"},{"_id":"6a5a55f19af9f73f38251212","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy murowe ceramiczne i silikatowe E","test_object_en":"Clay and calcium silicate masonry units E","methodology":"Absorpcja wody Zakres: (0,1 - 60) kg Metoda wagowa","methodology_en":"Water absorption Range: (0,1 - 60) kg Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Absorpcja wody Zakres: (0,1 - 60) kg Metoda wagowa","reference":"PN-EN 772-21","norm_bases":["PN-EN 772-21"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy murowe ceramiczne i silikatowe E Absorpcja wody Zakres: (0,1 - 60) kg Metoda wagowa PN-EN 772-21 Elementy murowe ceramiczne i silikatowe E Absorpcja wody Zakres: (0,1 - 60) kg Metoda wagowa PN-EN 772-21","categories":["water"],"row_index":766,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Clay and calcium silicate masonry units E Water absorption Range: (0,1 - 60) kg Gravimetric method PN-EN 772-21"},{"_id":"6a5a55f19af9f73f38251213","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy murowe ceramiczne z betonu kruszywowego i komórkowego E","test_object_en":"Masonry units of clay, aggregate concrete and aerated concrete E","methodology":"Gęstość brutto w stanie suchym Zakres: (1 - 60) kg Metoda wagowa","methodology_en":"Gross dry density Range: (1 - 60) kg Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Gęstość brutto w stanie suchym Zakres: (1 - 60) kg Metoda wagowa","reference":"PN-EN 772-13","norm_bases":["PN-EN 772-13"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy murowe ceramiczne z betonu kruszywowego i komórkowego E Gęstość brutto w stanie suchym Zakres: (1 - 60) kg Metoda wagowa PN-EN 772-13 Elementy murowe ceramiczne z betonu kruszywowego i komorkowego E Gestosc brutto w stanie suchym Zakres: (1 - 60) kg Metoda wagowa PN-EN 772-13","categories":["construction"],"row_index":767,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Masonry units of clay, aggregate concrete and aerated concrete E Gross dry density Range: (1 - 60) kg Gravimetric method PN-EN 772-13","search_zh":"陶瓷、集料混凝土与加气混凝土砌块 E PN-EN 772-13","test_object_zh":"陶瓷、集料混凝土与加气混凝土砌块 E"},{"_id":"6a5a55f19af9f73f38251214","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy murowe ceramiczne z betonu kruszywowego i komórkowego E","test_object_en":"Masonry units of clay, aggregate concrete and aerated concrete E","methodology":"Gęstość netto w stanie suchym Zakres: (1 - 60) kg Metoda wagowa","methodology_en":"Net dry density Range: (1 - 60) kg Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Gęstość netto w stanie suchym Zakres: (1 - 60) kg Metoda wagowa","reference":"PN-EN 772-13 + PN-EN 772-3","norm_bases":["PN-EN 772-13 + PN-EN 772-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy murowe ceramiczne z betonu kruszywowego i komórkowego E Gęstość netto w stanie suchym Zakres: (1 - 60) kg Metoda wagowa PN-EN 772-13 + PN-EN 772-3 Elementy murowe ceramiczne z betonu kruszywowego i komorkowego E Gestosc netto w stanie suchym Zakres: (1 - 60) kg Metoda wagowa PN-EN 772-13 + PN-EN 772-3","categories":["construction"],"row_index":768,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Masonry units of clay, aggregate concrete and aerated concrete E Net dry density Range: (1 - 60) kg Gravimetric method PN-EN 772-13 + PN-EN 772-3","search_zh":"陶瓷、集料混凝土与加气混凝土砌块 E PN-EN 772-13 + PN-EN 772-3","test_object_zh":"陶瓷、集料混凝土与加气混凝土砌块 E"},{"_id":"6a5a55f19af9f73f38251215","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy murowe ceramiczne z betonu kruszywowego i komórkowego E","test_object_en":"Masonry units of clay, aggregate concrete and aerated concrete E","methodology":"Wytrzymałość na ściskanie Zakres: (5 - 3000) kN Próba ściskania","methodology_en":"Compressive strength Range: (5 - 3000) kN Compression test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie Zakres: (5 - 3000) kN Próba ściskania","reference":"PN-EN 772-1","norm_bases":["PN-EN 772-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy murowe ceramiczne z betonu kruszywowego i komórkowego E Wytrzymałość na ściskanie Zakres: (5 - 3000) kN Próba ściskania PN-EN 772-1 Elementy murowe ceramiczne z betonu kruszywowego i komorkowego E Wytrzymalosc na sciskanie Zakres: (5 - 3000) kN Proba sciskania PN-EN 772-1","categories":["construction"],"row_index":769,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Masonry units of clay, aggregate concrete and aerated concrete E Compressive strength Range: (5 - 3000) kN Compression test PN-EN 772-1","search_zh":"陶瓷、集料混凝土与加气混凝土砌块 E PN-EN 772-1","test_object_zh":"陶瓷、集料混凝土与加气混凝土砌块 E"},{"_id":"6a5a55f19af9f73f38251216","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Gwoździe E","test_object_en":"Nails E","methodology":"Wymiary geometryczne liniowe Zakres: (0,1 - 400) mm","methodology_en":"Linear geometric dimensions Range: (0,1 - 400) mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary geometryczne liniowe Zakres: (0,1 - 400) mm","reference":"PN-EN 10230-1","norm_bases":["PN-EN 10230-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gwoździe E Wymiary geometryczne liniowe Zakres: (0,1 - 400) mm PN-EN 10230-1 Gwozdzie E Wymiary geometryczne liniowe Zakres: (0,1 - 400) mm PN-EN 10230-1","categories":["other"],"row_index":770,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Nails E Linear geometric dimensions Range: (0,1 - 400) mm PN-EN 10230-1"},{"_id":"6a5a55f19af9f73f38251217","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Gwoździe E","test_object_en":"Nails E","methodology":"Stan powierzchni okiem nieuzbrojonym Ocena wizualna","methodology_en":"Surface condition with the naked eye Visual assessment","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stan powierzchni okiem nieuzbrojonym Ocena wizualna","reference":"PN-EN 10230-1","norm_bases":["PN-EN 10230-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gwoździe E Stan powierzchni okiem nieuzbrojonym Ocena wizualna PN-EN 10230-1 Gwozdzie E Stan powierzchni okiem nieuzbrojonym Ocena wizualna PN-EN 10230-1","categories":["other"],"row_index":771,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Nails E Surface condition with the naked eye Visual assessment PN-EN 10230-1"},{"_id":"6a5a55f19af9f73f38251218","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Gwoździe i wkręty konstrukcyjne E","test_object_en":"Structural nails and screws E","methodology":"Moment charakterystyczny uplastycznienia - M y,k Wartość z obliczeń z wykorzystaniem f u Zakres: fu (400 - 600) MPa Próba rozciągania","methodology_en":"Characteristic yield moment - M y,k Value calculated using f u Range: fu (400 - 600) MPa Tensile test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moment charakterystyczny uplastycznienia - M y,k Wartość z obliczeń z wykorzystaniem f u Zakres: fu (400 - 600) MPa Próba rozciągania","reference":"PN-EN 1995-1-1 PN-EN 14592 „N”","norm_bases":["PN-EN 1995-1-1 PN-EN 14592 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gwoździe i wkręty konstrukcyjne E Moment charakterystyczny uplastycznienia - M y,k Wartość z obliczeń z wykorzystaniem f u Zakres: fu (400 - 600) MPa Próba rozciągania PN-EN 1995-1-1 PN-EN 14592 „N” Gwozdzie i wkrety konstrukcyjne E Moment charakterystyczny uplastycznienia - M y,k Wartosc z obliczen z wykorzystaniem f u Zakres: fu (400 - 600) MPa Proba rozciagania PN-EN 1995-1-1 PN-EN 14592 „N”","categories":["other"],"row_index":772,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Structural nails and screws E Characteristic yield moment - M y,k Value calculated using f u Range: fu (400 - 600) MPa Tensile test PN-EN 1995-1-1 PN-EN 14592 „N”","search_zh":"结构用钉与螺钉 E PN-EN 1995-1-1 PN-EN 14592 „N”","test_object_zh":"结构用钉与螺钉 E"},{"_id":"6a5a55f19af9f73f38251219","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Gwoździe i wkręty konstrukcyjne E","test_object_en":"Structural nails and screws E","methodology":"Wytrzymałość charakterystyczna na wyciąganie – f ax,k Zakres: siła (200 - 10000) N Próba rozciągania","methodology_en":"Characteristic withdrawal strength – f ax,k Range: force (200 - 10000) N Tensile test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość charakterystyczna na wyciąganie – f ax,k Zakres: siła (200 - 10000) N Próba rozciągania","reference":"PN-EN 1382 PN-EN 14592 „N”","norm_bases":["PN-EN 1382 PN-EN 14592 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gwoździe i wkręty konstrukcyjne E Wytrzymałość charakterystyczna na wyciąganie – f ax,k Zakres: siła (200 - 10000) N Próba rozciągania PN-EN 1382 PN-EN 14592 „N” Gwozdzie i wkrety konstrukcyjne E Wytrzymalosc charakterystyczna na wyciaganie – f ax,k Zakres: sila (200 - 10000) N Proba rozciagania PN-EN 1382 PN-EN 14592 „N”","categories":["other"],"row_index":773,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Structural nails and screws E Characteristic withdrawal strength – f ax,k Range: force (200 - 10000) N Tensile test PN-EN 1382 PN-EN 14592 „N”","search_zh":"结构用钉与螺钉 E PN-EN 1382 PN-EN 14592 „N”","test_object_zh":"结构用钉与螺钉 E"},{"_id":"6a5a55f19af9f73f3825121a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Gwoździe i wkręty konstrukcyjne E","test_object_en":"Structural nails and screws E","methodology":"Wytrzymałość charakterystyczna na przeciąganie główki – f head,k Zakres: siła (200 - 10000) N Próba rozciągania","methodology_en":"Characteristic head pull-through strength – f head,k Range: force (200 - 10000) N Tensile test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość charakterystyczna na przeciąganie główki – f head,k Zakres: siła (200 - 10000) N Próba rozciągania","reference":"PN-EN 1383 PN-EN 14592 „N”","norm_bases":["PN-EN 1383 PN-EN 14592 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gwoździe i wkręty konstrukcyjne E Wytrzymałość charakterystyczna na przeciąganie główki – f head,k Zakres: siła (200 - 10000) N Próba rozciągania PN-EN 1383 PN-EN 14592 „N” Gwozdzie i wkrety konstrukcyjne E Wytrzymalosc charakterystyczna na przeciaganie glowki – f head,k Zakres: sila (200 - 10000) N Proba rozciagania PN-EN 1383 PN-EN 14592 „N”","categories":["other"],"row_index":774,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Structural nails and screws E Characteristic head pull-through strength – f head,k Range: force (200 - 10000) N Tensile test PN-EN 1383 PN-EN 14592 „N”","search_zh":"结构用钉与螺钉 E PN-EN 1383 PN-EN 14592 „N”","test_object_zh":"结构用钉与螺钉 E"},{"_id":"6a5a55f19af9f73f3825121b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Gwoździe i wkręty konstrukcyjne E","test_object_en":"Structural nails and screws E","methodology":"Wytrzymałość charakterystyczna na rozciąganie – f tens,k Zakres: siła (200 - 10000) N Próba rozciągania","methodology_en":"Characteristic tensile strength – f tens,k Range: force (200 - 10000) N Tensile test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość charakterystyczna na rozciąganie – f tens,k Zakres: siła (200 - 10000) N Próba rozciągania","reference":"PN-EN 1383 PN-EN 14592 „N”","norm_bases":["PN-EN 1383 PN-EN 14592 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gwoździe i wkręty konstrukcyjne E Wytrzymałość charakterystyczna na rozciąganie – f tens,k Zakres: siła (200 - 10000) N Próba rozciągania PN-EN 1383 PN-EN 14592 „N” Gwozdzie i wkrety konstrukcyjne E Wytrzymalosc charakterystyczna na rozciaganie – f tens,k Zakres: sila (200 - 10000) N Proba rozciagania PN-EN 1383 PN-EN 14592 „N”","categories":["other"],"row_index":775,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Structural nails and screws E Characteristic tensile strength – f tens,k Range: force (200 - 10000) N Tensile test PN-EN 1383 PN-EN 14592 „N”","search_zh":"结构用钉与螺钉 E PN-EN 1383 PN-EN 14592 „N”","test_object_zh":"结构用钉与螺钉 E"},{"_id":"6a5a55f19af9f73f3825121c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Gwoździe i wkręty konstrukcyjne E","test_object_en":"Structural nails and screws E","methodology":"Wytrzymałość charakterystyczna na skręcanie – f tor,k Zakres: moment (1 - 30) Nm Próba skręcania","methodology_en":"Characteristic torsional strength – f tor,k Range: torque (1 - 30) Nm Torsion test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość charakterystyczna na skręcanie – f tor,k Zakres: moment (1 - 30) Nm Próba skręcania","reference":"PN-EN ISO 10666 PN-EN 14592","norm_bases":["PN-EN ISO 10666 PN-EN 14592"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gwoździe i wkręty konstrukcyjne E Wytrzymałość charakterystyczna na skręcanie – f tor,k Zakres: moment (1 - 30) Nm Próba skręcania PN-EN ISO 10666 PN-EN 14592 Gwozdzie i wkrety konstrukcyjne E Wytrzymalosc charakterystyczna na skrecanie – f tor,k Zakres: moment (1 - 30) Nm Proba skrecania PN-EN ISO 10666 PN-EN 14592","categories":["other"],"row_index":776,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Structural nails and screws E Characteristic torsional strength – f tor,k Range: torque (1 - 30) Nm Torsion test PN-EN ISO 10666 PN-EN 14592","search_zh":"结构用钉与螺钉 E PN-EN ISO 10666 PN-EN 14592","test_object_zh":"结构用钉与螺钉 E"},{"_id":"6a5a55f19af9f73f3825121d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kamień naturalny E","test_object_en":"Natural stone E","methodology":"Nośność trzpieni na rozłupanie kamienia Zakres: - siła: (1 - 10) kN - wymiar: (0,1 - 100) mm Próba wyrywania","methodology_en":"Load-bearing capacity of dowels against stone splitting Range: - force: (1 - 10) kN - dimension: (0,1 - 100) mm Pull-out test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność trzpieni na rozłupanie kamienia Zakres: - siła: (1 - 10) kN - wymiar: (0,1 - 100) mm Próba wyrywania","reference":"PN-EN 13364","norm_bases":["PN-EN 13364"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kamień naturalny E Nośność trzpieni na rozłupanie kamienia Zakres: - siła: (1 - 10) kN - wymiar: (0,1 - 100) mm Próba wyrywania PN-EN 13364 Kamien naturalny E Nosnosc trzpieni na rozlupanie kamienia Zakres: - sila: (1 - 10) kN - wymiar: (0,1 - 100) mm Proba wyrywania PN-EN 13364","categories":["other"],"row_index":777,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Natural stone E Load-bearing capacity of dowels against stone splitting Range: - force: (1 - 10) kN - dimension: (0,1 - 100) mm Pull-out test PN-EN 13364"},{"_id":"6a5a55f19af9f73f3825121e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kotwy, listwy kotwiące, wieszaki, wsporniki E","test_object_en":"Anchors, anchor rails, hangers, brackets E","methodology":"Nośność oraz zależność obciążenie- odkształcenie Zakres: (1 - 100) kN Próba rozciągania","methodology_en":"Load-bearing capacity and load-deformation relationship Range: (1 - 100) kN Tensile test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność oraz zależność obciążenie- odkształcenie Zakres: (1 - 100) kN Próba rozciągania","reference":"PN-EN 846-4 „N”","norm_bases":["PN-EN 846-4 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kotwy, listwy kotwiące, wieszaki, wsporniki E Nośność oraz zależność obciążenie- odkształcenie Zakres: (1 - 100) kN Próba rozciągania PN-EN 846-4 „N” Kotwy, listwy kotwiace, wieszaki, wsporniki E Nosnosc oraz zaleznosc obciazenie- odksztalcenie Zakres: (1 - 100) kN Proba rozciagania PN-EN 846-4 „N”","categories":["other"],"row_index":778,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Anchors, anchor rails, hangers, brackets E Load-bearing capacity and load-deformation relationship Range: (1 - 100) kN Tensile test PN-EN 846-4 „N”","search_zh":"锚栓、锚固条、吊件、支架 E PN-EN 846-4 „N”","test_object_zh":"锚栓、锚固条、吊件、支架 E"},{"_id":"6a5a55f19af9f73f3825121f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kotwy, listwy kotwiące, wieszaki, wsporniki E","test_object_en":"Anchors, anchor rails, hangers, brackets E","methodology":"Nośność na rozciąganie oraz sztywność Zakres: (1 - 100) kN Próba rozciągania","methodology_en":"Tensile load-bearing capacity and stiffness Range: (1 - 100) kN Tensile test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność na rozciąganie oraz sztywność Zakres: (1 - 100) kN Próba rozciągania","reference":"PN-EN 846-5 „N” PN-EN 846-6 „N”","norm_bases":["PN-EN 846-5 „N” PN-EN 846-6 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kotwy, listwy kotwiące, wieszaki, wsporniki E Nośność na rozciąganie oraz sztywność Zakres: (1 - 100) kN Próba rozciągania PN-EN 846-5 „N” PN-EN 846-6 „N” Kotwy, listwy kotwiace, wieszaki, wsporniki E Nosnosc na rozciaganie oraz sztywnosc Zakres: (1 - 100) kN Proba rozciagania PN-EN 846-5 „N” PN-EN 846-6 „N”","categories":["other"],"row_index":779,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Anchors, anchor rails, hangers, brackets E Tensile load-bearing capacity and stiffness Range: (1 - 100) kN Tensile test PN-EN 846-5 „N” PN-EN 846-6 „N”","search_zh":"锚栓、锚固条、吊件、支架 E PN-EN 846-5 „N” PN-EN 846-6 „N”","test_object_zh":"锚栓、锚固条、吊件、支架 E"},{"_id":"6a5a55f19af9f73f38251220","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kotwy, listwy kotwiące, wieszaki, wsporniki E","test_object_en":"Anchors, anchor rails, hangers, brackets E","methodology":"Nośność na ścinanie oraz sztywność Zakres: (1 - 100) kN Próba ścinania","methodology_en":"Shear load-bearing capacity and stiffness Range: (1 - 100) kN Shear test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność na ścinanie oraz sztywność Zakres: (1 - 100) kN Próba ścinania","reference":"PN-EN 846-7 „N”","norm_bases":["PN-EN 846-7 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kotwy, listwy kotwiące, wieszaki, wsporniki E Nośność na ścinanie oraz sztywność Zakres: (1 - 100) kN Próba ścinania PN-EN 846-7 „N” Kotwy, listwy kotwiace, wieszaki, wsporniki E Nosnosc na scinanie oraz sztywnosc Zakres: (1 - 100) kN Proba scinania PN-EN 846-7 „N”","categories":["other"],"row_index":780,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Anchors, anchor rails, hangers, brackets E Shear load-bearing capacity and stiffness Range: (1 - 100) kN Shear test PN-EN 846-7 „N”","search_zh":"锚栓、锚固条、吊件、支架 E PN-EN 846-7 „N”","test_object_zh":"锚栓、锚固条、吊件、支架 E"},{"_id":"6a5a55f19af9f73f38251221","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kotwy, listwy kotwiące, wieszaki, wsporniki E","test_object_en":"Anchors, anchor rails, hangers, brackets E","methodology":"Nośność oraz zależność obciążenie- odkształcenie Zakres: (1 - 100) kN Próba obciążenia","methodology_en":"Load-bearing capacity and load-deformation relationship Range: (1 - 100) kN Load test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność oraz zależność obciążenie- odkształcenie Zakres: (1 - 100) kN Próba obciążenia","reference":"PN-EN 846-8 „N”","norm_bases":["PN-EN 846-8 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kotwy, listwy kotwiące, wieszaki, wsporniki E Nośność oraz zależność obciążenie- odkształcenie Zakres: (1 - 100) kN Próba obciążenia PN-EN 846-8 „N” Kotwy, listwy kotwiace, wieszaki, wsporniki E Nosnosc oraz zaleznosc obciazenie- odksztalcenie Zakres: (1 - 100) kN Proba obciazenia PN-EN 846-8 „N”","categories":["other"],"row_index":781,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Anchors, anchor rails, hangers, brackets E Load-bearing capacity and load-deformation relationship Range: (1 - 100) kN Load test PN-EN 846-8 „N”","search_zh":"锚栓、锚固条、吊件、支架 E PN-EN 846-8 „N”","test_object_zh":"锚栓、锚固条、吊件、支架 E"},{"_id":"6a5a55f19af9f73f38251222","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kotwy, listwy kotwiące, wieszaki, wsporniki E","test_object_en":"Anchors, anchor rails, hangers, brackets E","methodology":"Nośność oraz charakterystyka obciążenie-ugięcie Zakres: (1 - 100) kN Próba ścinania na ramieniu","methodology_en":"Load-bearing capacity and load-deflection characteristic Range: (1 - 100) kN Shear test with lever arm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność oraz charakterystyka obciążenie-ugięcie Zakres: (1 - 100) kN Próba ścinania na ramieniu","reference":"PN-EN 846-10 „N”","norm_bases":["PN-EN 846-10 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kotwy, listwy kotwiące, wieszaki, wsporniki E Nośność oraz charakterystyka obciążenie-ugięcie Zakres: (1 - 100) kN Próba ścinania na ramieniu PN-EN 846-10 „N” Kotwy, listwy kotwiace, wieszaki, wsporniki E Nosnosc oraz charakterystyka obciazenie-ugiecie Zakres: (1 - 100) kN Proba scinania na ramieniu PN-EN 846-10 „N”","categories":["other"],"row_index":782,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Anchors, anchor rails, hangers, brackets E Load-bearing capacity and load-deflection characteristic Range: (1 - 100) kN Shear test with lever arm PN-EN 846-10 „N”","search_zh":"锚栓、锚固条、吊件、支架 E PN-EN 846-10 „N”","test_object_zh":"锚栓、锚固条、吊件、支架 E"},{"_id":"6a5a55f19af9f73f38251223","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kotwy, listwy kotwiące, wieszaki, wsporniki E","test_object_en":"Anchors, anchor rails, hangers, brackets E","methodology":"Nośność na ściskanie oraz sztywność Zakres: (1 - 100) kN Próba ściskania","methodology_en":"Compressive load-bearing capacity and stiffness Range: (1 - 100) kN Compression test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność na ściskanie oraz sztywność Zakres: (1 - 100) kN Próba ściskania","reference":"PN-EN 846-5 „N” PN-EN 846-6 „N”","norm_bases":["PN-EN 846-5 „N” PN-EN 846-6 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kotwy, listwy kotwiące, wieszaki, wsporniki E Nośność na ściskanie oraz sztywność Zakres: (1 - 100) kN Próba ściskania PN-EN 846-5 „N” PN-EN 846-6 „N” Kotwy, listwy kotwiace, wieszaki, wsporniki E Nosnosc na sciskanie oraz sztywnosc Zakres: (1 - 100) kN Proba sciskania PN-EN 846-5 „N” PN-EN 846-6 „N”","categories":["other"],"row_index":783,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Anchors, anchor rails, hangers, brackets E Compressive load-bearing capacity and stiffness Range: (1 - 100) kN Compression test PN-EN 846-5 „N” PN-EN 846-6 „N”","search_zh":"锚栓、锚固条、吊件、支架 E PN-EN 846-5 „N” PN-EN 846-6 „N”","test_object_zh":"锚栓、锚固条、吊件、支架 E"},{"_id":"6a5a55f19af9f73f38251224","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kotwy, listwy kotwiące, wieszaki, wsporniki E","test_object_en":"Anchors, anchor rails, hangers, brackets E","methodology":"Przemieszczenie pod obciążeniem Zakres: (0,1 - 100) mm Próba rozciągania i ścinania","methodology_en":"Displacement under load Range: (0,1 - 100) mm Tensile and shear test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przemieszczenie pod obciążeniem Zakres: (0,1 - 100) mm Próba rozciągania i ścinania","reference":"PN-EN 846-5 „N” PN-EN 846-6 „N” PN-EN 846-8 „N”","norm_bases":["PN-EN 846-5 „N” PN-EN 846-6 „N” PN-EN 846-8 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kotwy, listwy kotwiące, wieszaki, wsporniki E Przemieszczenie pod obciążeniem Zakres: (0,1 - 100) mm Próba rozciągania i ścinania PN-EN 846-5 „N” PN-EN 846-6 „N” PN-EN 846-8 „N” Kotwy, listwy kotwiace, wieszaki, wsporniki E Przemieszczenie pod obciazeniem Zakres: (0,1 - 100) mm Proba rozciagania i scinania PN-EN 846-5 „N” PN-EN 846-6 „N” PN-EN 846-8 „N”","categories":["other"],"row_index":784,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Anchors, anchor rails, hangers, brackets E Displacement under load Range: (0,1 - 100) mm Tensile and shear test PN-EN 846-5 „N” PN-EN 846-6 „N” PN-EN 846-8 „N”","search_zh":"锚栓、锚固条、吊件、支架 E PN-EN 846-5 „N” PN-EN 846-6 „N” PN-EN 846-8 „N”","test_object_zh":"锚栓、锚固条、吊件、支架 E"},{"_id":"6a5a55f19af9f73f38251225","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Krawężniki betonowe E","test_object_en":"Concrete kerbs E","methodology":"Wytrzymałość na zginanie Zakres: (1 - 100) kN Próba zginania","methodology_en":"Bending strength Range: (1 - 100) kN Bending test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na zginanie Zakres: (1 - 100) kN Próba zginania","reference":"PN-EN 1340, Załącznik F","norm_bases":["PN-EN 1340, Załącznik F"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Krawężniki betonowe E Wytrzymałość na zginanie Zakres: (1 - 100) kN Próba zginania PN-EN 1340, Załącznik F Krawezniki betonowe E Wytrzymalosc na zginanie Zakres: (1 - 100) kN Proba zginania PN-EN 1340, Zalacznik F","categories":["construction"],"row_index":785,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete kerbs E Bending strength Range: (1 - 100) kN Bending test PN-EN 1340, Załącznik F","search_zh":"混凝土路缘石 E PN-EN 1340, Załącznik F","test_object_zh":"混凝土路缘石 E"},{"_id":"6a5a55f19af9f73f38251226","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Łączniki do mocowania elementów cienkościennych i warstwowych E","test_object_en":"Fasteners for fixing thin-walled and sandwich elements E","methodology":"Średnica wywierconego otworu Zakres: (0,1 - 150) mm Pomiar liniowy","methodology_en":"Diameter of the drilled hole Range: (0,1 - 150) mm Linear measurement","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Średnica wywierconego otworu Zakres: (0,1 - 150) mm Pomiar liniowy","reference":"PN-EN ISO 10666","norm_bases":["PN-EN ISO 10666"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łączniki do mocowania elementów cienkościennych i warstwowych E Średnica wywierconego otworu Zakres: (0,1 - 150) mm Pomiar liniowy PN-EN ISO 10666 Laczniki do mocowania elementow cienkosciennych i warstwowych E Srednica wywierconego otworu Zakres: (0,1 - 150) mm Pomiar liniowy PN-EN ISO 10666","categories":["other"],"row_index":786,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fasteners for fixing thin-walled and sandwich elements E Diameter of the drilled hole Range: (0,1 - 150) mm Linear measurement PN-EN ISO 10666","search_zh":"薄壁与夹芯构件固定用连接件 E PN-EN ISO 10666","test_object_zh":"薄壁与夹芯构件固定用连接件 E"},{"_id":"6a5a55f19af9f73f38251227","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Łączniki do mocowania elementów cienkościennych i warstwowych E","test_object_en":"Fasteners for fixing thin-walled and sandwich elements E","methodology":"Zdolność skręcania wkręta Zakres: (1 - 30) Nm Próba obciążenia momentem","methodology_en":"Screw driving capability Range: (1 - 30) Nm Torque loading test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność skręcania wkręta Zakres: (1 - 30) Nm Próba obciążenia momentem","reference":"PN-EN ISO 10666 | PN-EN ISO 2702","norm_bases":["PN-EN ISO 10666","PN-EN ISO 2702"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łączniki do mocowania elementów cienkościennych i warstwowych E Zdolność skręcania wkręta Zakres: (1 - 30) Nm Próba obciążenia momentem PN-EN ISO 10666 | PN-EN ISO 2702 Laczniki do mocowania elementow cienkosciennych i warstwowych E Zdolnosc skrecania wkreta Zakres: (1 - 30) Nm Proba obciazenia momentem PN-EN ISO 10666 | PN-EN ISO 2702","categories":["other"],"row_index":787,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fasteners for fixing thin-walled and sandwich elements E Screw driving capability Range: (1 - 30) Nm Torque loading test PN-EN ISO 10666 | PN-EN ISO 2702","search_zh":"薄壁与夹芯构件固定用连接件 E PN-EN ISO 10666 | PN-EN ISO 2702","test_object_zh":"薄壁与夹芯构件固定用连接件 E"},{"_id":"6a5a55f19af9f73f38251228","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Łączniki do mocowania elementów cienkościennych i warstwowych E","test_object_en":"Fasteners for fixing thin-walled and sandwich elements E","methodology":"Zdolność wkręcania do blach stalowych Zakres: (1 - 99) s Próba wkręcania","methodology_en":"Screwing-in capability into steel sheets Range: (1 - 99) s Screwing-in test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność wkręcania do blach stalowych Zakres: (1 - 99) s Próba wkręcania","reference":"PN-EN ISO 10666","norm_bases":["PN-EN ISO 10666"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łączniki do mocowania elementów cienkościennych i warstwowych E Zdolność wkręcania do blach stalowych Zakres: (1 - 99) s Próba wkręcania PN-EN ISO 10666 Laczniki do mocowania elementow cienkosciennych i warstwowych E Zdolnosc wkrecania do blach stalowych Zakres: (1 - 99) s Proba wkrecania PN-EN ISO 10666","categories":["materials"],"row_index":788,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fasteners for fixing thin-walled and sandwich elements E Screwing-in capability into steel sheets Range: (1 - 99) s Screwing-in test PN-EN ISO 10666","search_zh":"薄壁与夹芯构件固定用连接件 E PN-EN ISO 10666","test_object_zh":"薄壁与夹芯构件固定用连接件 E"},{"_id":"6a5a55f19af9f73f38251229","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Łączniki metalowe: rozporowe, wbijane, wkręcane E","test_object_en":"Metal fasteners: expansion, drive-in, screw-in E","methodology":"Nośność łączników gwintowanych Zakres: (1 - 1000) kN Próba rozciągania","methodology_en":"Load capacity of threaded fasteners Range: (1 - 1000) kN Tensile test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność łączników gwintowanych Zakres: (1 - 1000) kN Próba rozciągania","reference":"PN-EN ISO 898-1 PN-EN ISO 3506-1","norm_bases":["PN-EN ISO 898-1 PN-EN ISO 3506-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łączniki metalowe: rozporowe, wbijane, wkręcane E Nośność łączników gwintowanych Zakres: (1 - 1000) kN Próba rozciągania PN-EN ISO 898-1 PN-EN ISO 3506-1 Laczniki metalowe: rozporowe, wbijane, wkrecane E Nosnosc lacznikow gwintowanych Zakres: (1 - 1000) kN Proba rozciagania PN-EN ISO 898-1 PN-EN ISO 3506-1","categories":["materials"],"row_index":789,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Metal fasteners: expansion, drive-in, screw-in E Load capacity of threaded fasteners Range: (1 - 1000) kN Tensile test PN-EN ISO 898-1 PN-EN ISO 3506-1","search_zh":"金属连接件：膨胀式、打入式、旋入式 E PN-EN ISO 898-1 PN-EN ISO 3506-1","test_object_zh":"金属连接件：膨胀式、打入式、旋入式 E"},{"_id":"6a5a55f19af9f73f3825122a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Łączniki metalowe wklejane E","test_object_en":"Bonded metal anchors E","methodology":"Nośność łączników gwintowanych Zakres: (1 - 1000) kN Próba rozciągania","methodology_en":"Load capacity of threaded fasteners Range: (1 - 1000) kN Tensile test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność łączników gwintowanych Zakres: (1 - 1000) kN Próba rozciągania","reference":"PN-EN ISO 898-1 PN-EN ISO 3506-1","norm_bases":["PN-EN ISO 898-1 PN-EN ISO 3506-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łączniki metalowe wklejane E Nośność łączników gwintowanych Zakres: (1 - 1000) kN Próba rozciągania PN-EN ISO 898-1 PN-EN ISO 3506-1 Laczniki metalowe wklejane E Nosnosc lacznikow gwintowanych Zakres: (1 - 1000) kN Proba rozciagania PN-EN ISO 898-1 PN-EN ISO 3506-1","categories":["materials"],"row_index":790,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Bonded metal anchors E Load capacity of threaded fasteners Range: (1 - 1000) kN Tensile test PN-EN ISO 898-1 PN-EN ISO 3506-1","search_zh":"植筋用金属锚固件 E PN-EN ISO 898-1 PN-EN ISO 3506-1","test_object_zh":"植筋用金属锚固件 E"},{"_id":"6a5a55f19af9f73f3825122b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Łączniki do mocowania termoizolacji E","test_object_en":"Fasteners for fixing thermal insulation E","methodology":"Maksymalny moment obrotowy Zakres: (1 - 100) Nm Próba obciążenia momentem","methodology_en":"Maximum torque Range: (1 - 100) Nm Torque loading test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Maksymalny moment obrotowy Zakres: (1 - 100) Nm Próba obciążenia momentem","reference":"EAD 330196-xx-060","norm_bases":["EAD 330196-xx-060"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łączniki do mocowania termoizolacji E Maksymalny moment obrotowy Zakres: (1 - 100) Nm Próba obciążenia momentem EAD 330196-xx-060 Laczniki do mocowania termoizolacji E Maksymalny moment obrotowy Zakres: (1 - 100) Nm Proba obciazenia momentem EAD 330196-xx-060","categories":["other"],"row_index":791,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fasteners for fixing thermal insulation E Maximum torque Range: (1 - 100) Nm Torque loading test EAD 330196-xx-060","search_zh":"保温层固定用连接件 E EAD 330196-xx-060","test_object_zh":"保温层固定用连接件 E"},{"_id":"6a5a55f19af9f73f3825122c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Łączniki do mocowania termoizolacji E","test_object_en":"Fasteners for fixing thermal insulation E","methodology":"Nośność na wyrywanie z podłoża: beton zwykły, beton lekki pełny, beton lekki z otworami, podłoże ceramiczne pełne, podłoże ceramiczne z otworami, beton lekki autoklawizowany Zakres: (0,01 - 10) kN Próba rozciągania","methodology_en":"Pull-out load-bearing capacity from the substrate: normal-weight concrete, solid lightweight concrete, perforated lightweight concrete, solid ceramic substrate, perforated ceramic substrate, autoclaved aerated lightweight concrete Range: (0,01 - 10) kN Tensile test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność na wyrywanie z podłoża: beton zwykły, beton lekki pełny, beton lekki z otworami, podłoże ceramiczne pełne, podłoże ceramiczne z otworami, beton lekki autoklawizowany Zakres: (0,01 - 10) kN Próba rozciągania","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łączniki do mocowania termoizolacji E Nośność na wyrywanie z podłoża: beton zwykły, beton lekki pełny, beton lekki z otworami, podłoże ceramiczne pełne, podłoże ceramiczne z otworami, beton lekki autoklawizowany Zakres: (0,01 - 10) kN Próba rozciągania Laczniki do mocowania termoizolacji E Nosnosc na wyrywanie z podloza: beton zwykly, beton lekki pelny, beton lekki z otworami, podloze ceramiczne pelne, podloze ceramiczne z otworami, beton lekki autoklawizowany Zakres: (0,01 - 10) kN Proba rozciagania","categories":["construction"],"row_index":792,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fasteners for fixing thermal insulation E Pull-out load-bearing capacity from the substrate: normal-weight concrete, solid lightweight concrete, perforated lightweight concrete, solid ceramic substrate, perforated ceramic substrate, autoclaved aerated lightweight concrete Range: (0,01 - 10) kN Tensile test","search_zh":"保温层固定用连接件 E","test_object_zh":"保温层固定用连接件 E"},{"_id":"6a5a55f19af9f73f3825122d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Łączniki do mocowania termoizolacji E","test_object_en":"Fasteners for fixing thermal insulation E","methodology":"Odporność na obciążeniem wiatrem polegająca na oddziaływaniu statycznym poprzez blok piankowy Zakres: (1 - 50) kN Próba rozciągania","methodology_en":"Resistance to wind load consisting in static action through a foam block Range: (1 - 50) kN Tensile test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążeniem wiatrem polegająca na oddziaływaniu statycznym poprzez blok piankowy Zakres: (1 - 50) kN Próba rozciągania","reference":"EAD 040083-xx-0404 EAD 040287-xx-0404","norm_bases":["EAD 040083-xx-0404 EAD 040287-xx-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łączniki do mocowania termoizolacji E Odporność na obciążeniem wiatrem polegająca na oddziaływaniu statycznym poprzez blok piankowy Zakres: (1 - 50) kN Próba rozciągania EAD 040083-xx-0404 EAD 040287-xx-0404 Laczniki do mocowania termoizolacji E Odpornosc na obciazeniem wiatrem polegajaca na oddzialywaniu statycznym poprzez blok piankowy Zakres: (1 - 50) kN Proba rozciagania EAD 040083-xx-0404 EAD 040287-xx-0404","categories":["other"],"row_index":793,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fasteners for fixing thermal insulation E Resistance to wind load consisting in static action through a foam block Range: (1 - 50) kN Tensile test EAD 040083-xx-0404 EAD 040287-xx-0404","search_zh":"保温层固定用连接件 E EAD 040083-xx-0404 EAD 040287-xx-0404","test_object_zh":"保温层固定用连接件 E"},{"_id":"6a5a55f19af9f73f3825122e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Łączniki do mocowania termoizolacji E","test_object_en":"Fasteners for fixing thermal insulation E","methodology":"Odporność na obciążeniem wiatrem polegająca na przeciąganiu łączników przez wyrób do izolacji cieplnej Zakres: (1 - 10) kN Próba rozciągania","methodology_en":"Resistance to wind load consisting in pull-through of fasteners through the thermal insulation product Range: (1 - 10) kN Tensile test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążeniem wiatrem polegająca na przeciąganiu łączników przez wyrób do izolacji cieplnej Zakres: (1 - 10) kN Próba rozciągania","reference":"EAD 040083-xx-0404 EAD 040287-xx-0404","norm_bases":["EAD 040083-xx-0404 EAD 040287-xx-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łączniki do mocowania termoizolacji E Odporność na obciążeniem wiatrem polegająca na przeciąganiu łączników przez wyrób do izolacji cieplnej Zakres: (1 - 10) kN Próba rozciągania EAD 040083-xx-0404 EAD 040287-xx-0404 Laczniki do mocowania termoizolacji E Odpornosc na obciazeniem wiatrem polegajaca na przeciaganiu lacznikow przez wyrob do izolacji cieplnej Zakres: (1 - 10) kN Proba rozciagania EAD 040083-xx-0404 EAD 040287-xx-0404","categories":["construction"],"row_index":794,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fasteners for fixing thermal insulation E Resistance to wind load consisting in pull-through of fasteners through the thermal insulation product Range: (1 - 10) kN Tensile test EAD 040083-xx-0404 EAD 040287-xx-0404","search_zh":"保温层固定用连接件 E EAD 040083-xx-0404 EAD 040287-xx-0404","test_object_zh":"保温层固定用连接件 E"},{"_id":"6a5a55f19af9f73f3825122f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Łączniki do mocowania elementów cienkościennych i warstwowych E","test_object_en":"Fasteners for fixing thin-walled and sandwich elements E","methodology":"Nośność na ścinanie Zakres: (0,5 - 50) kN Próba ścinania","methodology_en":"Shear load capacity Range: (0,5 - 50) kN Shear test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność na ścinanie Zakres: (0,5 - 50) kN Próba ścinania","reference":"EAD 330046-xx-0602 EAD 330047-xx-0602","norm_bases":["EAD 330046-xx-0602 EAD 330047-xx-0602"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łączniki do mocowania elementów cienkościennych i warstwowych E Nośność na ścinanie Zakres: (0,5 - 50) kN Próba ścinania EAD 330046-xx-0602 EAD 330047-xx-0602 Laczniki do mocowania elementow cienkosciennych i warstwowych E Nosnosc na scinanie Zakres: (0,5 - 50) kN Proba scinania EAD 330046-xx-0602 EAD 330047-xx-0602","categories":["other"],"row_index":795,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fasteners for fixing thin-walled and sandwich elements E Shear load capacity Range: (0,5 - 50) kN Shear test EAD 330046-xx-0602 EAD 330047-xx-0602","search_zh":"薄壁与夹芯构件固定用连接件 E EAD 330046-xx-0602 EAD 330047-xx-0602","test_object_zh":"薄壁与夹芯构件固定用连接件 E"},{"_id":"6a5a55f19af9f73f38251230","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Łączniki do mocowania elementów cienkościennych i warstwowych E","test_object_en":"Fasteners for fixing thin-walled and sandwich elements E","methodology":"Nośność na wyrywanie Zakres: (0,5 - 50) kN Próba wyrywania","methodology_en":"Pull-out load-bearing capacity Range: (0,5 - 50) kN Pull-out test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność na wyrywanie Zakres: (0,5 - 50) kN Próba wyrywania","reference":"EAD 330046-xx-0602 EAD 330047-xx-0602","norm_bases":["EAD 330046-xx-0602 EAD 330047-xx-0602"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łączniki do mocowania elementów cienkościennych i warstwowych E Nośność na wyrywanie Zakres: (0,5 - 50) kN Próba wyrywania EAD 330046-xx-0602 EAD 330047-xx-0602 Laczniki do mocowania elementow cienkosciennych i warstwowych E Nosnosc na wyrywanie Zakres: (0,5 - 50) kN Proba wyrywania EAD 330046-xx-0602 EAD 330047-xx-0602","categories":["other"],"row_index":796,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fasteners for fixing thin-walled and sandwich elements E Pull-out load-bearing capacity Range: (0,5 - 50) kN Pull-out test EAD 330046-xx-0602 EAD 330047-xx-0602","search_zh":"薄壁与夹芯构件固定用连接件 E EAD 330046-xx-0602 EAD 330047-xx-0602","test_object_zh":"薄壁与夹芯构件固定用连接件 E"},{"_id":"6a5a55f19af9f73f38251231","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Łączniki metalowe: rozporowe, wbijane, wkręcane E","test_object_en":"Metal fasteners: expansion, drive-in, screw-in E","methodology":"Nośność na ścinanie Zakres: (1 - 200) kN Próba ścinania","methodology_en":"Shear load capacity Range: (1 - 200) kN Shear test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność na ścinanie Zakres: (1 - 200) kN Próba ścinania","reference":"EAD 330232-xx-0601 EAD 330747-xx-0601 + TR048","norm_bases":["EAD 330232-xx-0601 EAD 330747-xx-0601 + TR048"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łączniki metalowe: rozporowe, wbijane, wkręcane E Nośność na ścinanie Zakres: (1 - 200) kN Próba ścinania EAD 330232-xx-0601 EAD 330747-xx-0601 + TR048 Laczniki metalowe: rozporowe, wbijane, wkrecane E Nosnosc na scinanie Zakres: (1 - 200) kN Proba scinania EAD 330232-xx-0601 EAD 330747-xx-0601 + TR048","categories":["materials"],"row_index":797,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Metal fasteners: expansion, drive-in, screw-in E Shear load capacity Range: (1 - 200) kN Shear test EAD 330232-xx-0601 EAD 330747-xx-0601 + TR048","search_zh":"金属连接件：膨胀式、打入式、旋入式 E EAD 330232-xx-0601 EAD 330747-xx-0601 + TR048","test_object_zh":"金属连接件：膨胀式、打入式、旋入式 E"},{"_id":"6a5a55f19af9f73f38251232","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Łączniki metalowe: rozporowe, wbijane, wkręcane E","test_object_en":"Metal fasteners: expansion, drive-in, screw-in E","methodology":"Nośność na wyrywanie Zakres: (1 - 900) kN Próba wyrywania","methodology_en":"Pull-out load capacity Range: (1 - 900) kN Pull-out test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność na wyrywanie Zakres: (1 - 900) kN Próba wyrywania","reference":"EAD 330232-xx-0601 EAD 330747-xx-0601 + TR048","norm_bases":["EAD 330232-xx-0601 EAD 330747-xx-0601 + TR048"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łączniki metalowe: rozporowe, wbijane, wkręcane E Nośność na wyrywanie Zakres: (1 - 900) kN Próba wyrywania EAD 330232-xx-0601 EAD 330747-xx-0601 + TR048 Laczniki metalowe: rozporowe, wbijane, wkrecane E Nosnosc na wyrywanie Zakres: (1 - 900) kN Proba wyrywania EAD 330232-xx-0601 EAD 330747-xx-0601 + TR048","categories":["materials"],"row_index":798,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Metal fasteners: expansion, drive-in, screw-in E Pull-out load capacity Range: (1 - 900) kN Pull-out test EAD 330232-xx-0601 EAD 330747-xx-0601 + TR048","search_zh":"金属连接件：膨胀式、打入式、旋入式 E EAD 330232-xx-0601 EAD 330747-xx-0601 + TR048","test_object_zh":"金属连接件：膨胀式、打入式、旋入式 E"},{"_id":"6a5a55f19af9f73f38251233","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Łączniki metalowe: rozporowe, wbijane, wkręcane E","test_object_en":"Metal fasteners: expansion, drive-in, screw-in E","methodology":"Odporność na moment maksymalny Zakres: (5 - 1000) Nm Próba obciążenia momentem","methodology_en":"Resistance to maximum torque Range: (5 - 1000) Nm Torque loading test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na moment maksymalny Zakres: (5 - 1000) Nm Próba obciążenia momentem","reference":"EAD 330232-xx-0601 EAD 330747-xx-0601 + TR048","norm_bases":["EAD 330232-xx-0601 EAD 330747-xx-0601 + TR048"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łączniki metalowe: rozporowe, wbijane, wkręcane E Odporność na moment maksymalny Zakres: (5 - 1000) Nm Próba obciążenia momentem EAD 330232-xx-0601 EAD 330747-xx-0601 + TR048 Laczniki metalowe: rozporowe, wbijane, wkrecane E Odpornosc na moment maksymalny Zakres: (5 - 1000) Nm Proba obciazenia momentem EAD 330232-xx-0601 EAD 330747-xx-0601 + TR048","categories":["materials"],"row_index":799,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Metal fasteners: expansion, drive-in, screw-in E Resistance to maximum torque Range: (5 - 1000) Nm Torque loading test EAD 330232-xx-0601 EAD 330747-xx-0601 + TR048","search_zh":"金属连接件：膨胀式、打入式、旋入式 E EAD 330232-xx-0601 EAD 330747-xx-0601 + TR048","test_object_zh":"金属连接件：膨胀式、打入式、旋入式 E"},{"_id":"6a5a55f19af9f73f38251234","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Łączniki metalowe: rozporowe, wbijane, wkręcane E","test_object_en":"Metal fasteners: expansion, drive-in, screw-in E","methodology":"Odporność na moment niszczący Zakres: (5 - 1000) Nm Próba obciążenia momentem","methodology_en":"Resistance to breaking torque Range: (5 - 1000) Nm Torque loading test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na moment niszczący Zakres: (5 - 1000) Nm Próba obciążenia momentem","reference":"EAD 330232-xx-0601 EAD 330747-xx-0601 + TR048","norm_bases":["EAD 330232-xx-0601 EAD 330747-xx-0601 + TR048"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łączniki metalowe: rozporowe, wbijane, wkręcane E Odporność na moment niszczący Zakres: (5 - 1000) Nm Próba obciążenia momentem EAD 330232-xx-0601 EAD 330747-xx-0601 + TR048 Laczniki metalowe: rozporowe, wbijane, wkrecane E Odpornosc na moment niszczacy Zakres: (5 - 1000) Nm Proba obciazenia momentem EAD 330232-xx-0601 EAD 330747-xx-0601 + TR048","categories":["materials"],"row_index":800,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Metal fasteners: expansion, drive-in, screw-in E Resistance to breaking torque Range: (5 - 1000) Nm Torque loading test EAD 330232-xx-0601 EAD 330747-xx-0601 + TR048","search_zh":"金属连接件：膨胀式、打入式、旋入式 E EAD 330232-xx-0601 EAD 330747-xx-0601 + TR048","test_object_zh":"金属连接件：膨胀式、打入式、旋入式 E"},{"_id":"6a5a55f19af9f73f38251235","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Łączniki metalowe wklejane E","test_object_en":"Bonded metal anchors E","methodology":"Nośność na ścinanie Zakres: (1 - 200) kN Próba ścinania","methodology_en":"Shear load capacity Range: (1 - 200) kN Shear test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność na ścinanie Zakres: (1 - 200) kN Próba ścinania","reference":"EAD 330499-xx-0601","norm_bases":["EAD 330499-xx-0601"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łączniki metalowe wklejane E Nośność na ścinanie Zakres: (1 - 200) kN Próba ścinania EAD 330499-xx-0601 Laczniki metalowe wklejane E Nosnosc na scinanie Zakres: (1 - 200) kN Proba scinania EAD 330499-xx-0601","categories":["materials"],"row_index":801,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Bonded metal anchors E Shear load capacity Range: (1 - 200) kN Shear test EAD 330499-xx-0601","search_zh":"植筋用金属锚固件 E EAD 330499-xx-0601","test_object_zh":"植筋用金属锚固件 E"},{"_id":"6a5a55f19af9f73f38251236","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Łączniki metalowe wklejane E","test_object_en":"Bonded metal anchors E","methodology":"Nośność na wyrywanie Zakres: (1 - 900) kN Próba wyrywania","methodology_en":"Pull-out load capacity Range: (1 - 900) kN Pull-out test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność na wyrywanie Zakres: (1 - 900) kN Próba wyrywania","reference":"EAD 330499-xx-0601","norm_bases":["EAD 330499-xx-0601"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łączniki metalowe wklejane E Nośność na wyrywanie Zakres: (1 - 900) kN Próba wyrywania EAD 330499-xx-0601 Laczniki metalowe wklejane E Nosnosc na wyrywanie Zakres: (1 - 900) kN Proba wyrywania EAD 330499-xx-0601","categories":["materials"],"row_index":802,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Bonded metal anchors E Pull-out load capacity Range: (1 - 900) kN Pull-out test EAD 330499-xx-0601","search_zh":"植筋用金属锚固件 E EAD 330499-xx-0601","test_object_zh":"植筋用金属锚固件 E"},{"_id":"6a5a55f19af9f73f38251237","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Łączniki metalowe wklejane E","test_object_en":"Bonded metal anchors E","methodology":"Nośność na wyrywanie z podłoża ceramicznego pełnego i z otworami, betonu lekkiego pełnego i z otworami, betonu autoklawizowanego Zakres: (1 - 900) kN Próba wyrywania","methodology_en":"Pull-out load-bearing capacity from solid and perforated ceramic substrate, solid and perforated lightweight concrete, autoclaved aerated concrete Range: (1 - 900) kN Pull-out test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność na wyrywanie z podłoża ceramicznego pełnego i z otworami, betonu lekkiego pełnego i z otworami, betonu autoklawizowanego Zakres: (1 - 900) kN Próba wyrywania","reference":"EAD 330076-xx-0604","norm_bases":["EAD 330076-xx-0604"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łączniki metalowe wklejane E Nośność na wyrywanie z podłoża ceramicznego pełnego i z otworami, betonu lekkiego pełnego i z otworami, betonu autoklawizowanego Zakres: (1 - 900) kN Próba wyrywania EAD 330076-xx-0604 Laczniki metalowe wklejane E Nosnosc na wyrywanie z podloza ceramicznego pelnego i z otworami, betonu lekkiego pelnego i z otworami, betonu autoklawizowanego Zakres: (1 - 900) kN Proba wyrywania EAD 330076-xx-0604","categories":["materials","construction"],"row_index":803,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Bonded metal anchors E Pull-out load-bearing capacity from solid and perforated ceramic substrate, solid and perforated lightweight concrete, autoclaved aerated concrete Range: (1 - 900) kN Pull-out test EAD 330076-xx-0604","search_zh":"植筋用金属锚固件 E EAD 330076-xx-0604","test_object_zh":"植筋用金属锚固件 E"},{"_id":"6a5a55f19af9f73f38251238","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Łączniki metalowe wklejane E","test_object_en":"Bonded metal anchors E","methodology":"Nośność na ścinanie z podłoża ceramicznego pełnego i z otworami, betonu lekkiego pełnego i z otworami, betonu autoklawizowanego Zakres: (1 - 200) kN Próba ścinania","methodology_en":"Shear load-bearing capacity in solid and perforated ceramic substrate, solid and perforated lightweight concrete, autoclaved aerated concrete Range: (1 - 200) kN Shear test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność na ścinanie z podłoża ceramicznego pełnego i z otworami, betonu lekkiego pełnego i z otworami, betonu autoklawizowanego Zakres: (1 - 200) kN Próba ścinania","reference":"EAD 330076-xx-0604","norm_bases":["EAD 330076-xx-0604"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łączniki metalowe wklejane E Nośność na ścinanie z podłoża ceramicznego pełnego i z otworami, betonu lekkiego pełnego i z otworami, betonu autoklawizowanego Zakres: (1 - 200) kN Próba ścinania EAD 330076-xx-0604 Laczniki metalowe wklejane E Nosnosc na scinanie z podloza ceramicznego pelnego i z otworami, betonu lekkiego pelnego i z otworami, betonu autoklawizowanego Zakres: (1 - 200) kN Proba scinania EAD 330076-xx-0604","categories":["materials","construction"],"row_index":804,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Bonded metal anchors E Shear load-bearing capacity in solid and perforated ceramic substrate, solid and perforated lightweight concrete, autoclaved aerated concrete Range: (1 - 200) kN Shear test EAD 330076-xx-0604","search_zh":"植筋用金属锚固件 E EAD 330076-xx-0604","test_object_zh":"植筋用金属锚固件 E"},{"_id":"6a5a55f19af9f73f38251239","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Łączniki metalowe wklejane E","test_object_en":"Bonded metal anchors E","methodology":"Odporność na moment maksymalny Zakres: (1 - 1000) Nm Próba obciążenia momentem","methodology_en":"Resistance to maximum torque Range: (1 - 1000) Nm Torque loading test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na moment maksymalny Zakres: (1 - 1000) Nm Próba obciążenia momentem","reference":"EAD 330076-xx-0604","norm_bases":["EAD 330076-xx-0604"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łączniki metalowe wklejane E Odporność na moment maksymalny Zakres: (1 - 1000) Nm Próba obciążenia momentem EAD 330076-xx-0604 Laczniki metalowe wklejane E Odpornosc na moment maksymalny Zakres: (1 - 1000) Nm Proba obciazenia momentem EAD 330076-xx-0604","categories":["materials"],"row_index":805,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Bonded metal anchors E Resistance to maximum torque Range: (1 - 1000) Nm Torque loading test EAD 330076-xx-0604","search_zh":"植筋用金属锚固件 E EAD 330076-xx-0604","test_object_zh":"植筋用金属锚固件 E"},{"_id":"6a5a55f19af9f73f3825123a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Łączniki metalowe wklejane E","test_object_en":"Bonded metal anchors E","methodology":"Nośność spoiny klejowej w różnych warunkach kondycjonowania Zakres: (1 - 100) kN Próba ścinania","methodology_en":"Load-bearing capacity of the adhesive joint under various conditioning conditions Range: (1 - 100) kN Shear test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność spoiny klejowej w różnych warunkach kondycjonowania Zakres: (1 - 100) kN Próba ścinania","reference":"EAD 330499-xx-0601","norm_bases":["EAD 330499-xx-0601"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łączniki metalowe wklejane E Nośność spoiny klejowej w różnych warunkach kondycjonowania Zakres: (1 - 100) kN Próba ścinania EAD 330499-xx-0601 Laczniki metalowe wklejane E Nosnosc spoiny klejowej w roznych warunkach kondycjonowania Zakres: (1 - 100) kN Proba scinania EAD 330499-xx-0601","categories":["materials"],"row_index":806,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Bonded metal anchors E Load-bearing capacity of the adhesive joint under various conditioning conditions Range: (1 - 100) kN Shear test EAD 330499-xx-0601","search_zh":"植筋用金属锚固件 E EAD 330499-xx-0601","test_object_zh":"植筋用金属锚固件 E"},{"_id":"6a5a55f19af9f73f3825123b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Łączniki metalowe wklejane E","test_object_en":"Bonded metal anchors E","methodology":"Odporność na moment maksymalny Zakres: (1 - 1000) Nm Próba obciążenia momentem","methodology_en":"Resistance to maximum torque Range: (1 - 1000) Nm Torque loading test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na moment maksymalny Zakres: (1 - 1000) Nm Próba obciążenia momentem","reference":"EAD 330499-xx-0601","norm_bases":["EAD 330499-xx-0601"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łączniki metalowe wklejane E Odporność na moment maksymalny Zakres: (1 - 1000) Nm Próba obciążenia momentem EAD 330499-xx-0601 Laczniki metalowe wklejane E Odpornosc na moment maksymalny Zakres: (1 - 1000) Nm Proba obciazenia momentem EAD 330499-xx-0601","categories":["materials"],"row_index":807,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Bonded metal anchors E Resistance to maximum torque Range: (1 - 1000) Nm Torque loading test EAD 330499-xx-0601","search_zh":"植筋用金属锚固件 E EAD 330499-xx-0601","test_object_zh":"植筋用金属锚固件 E"},{"_id":"6a5a55f19af9f73f3825123c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Łączniki metalowe wklejane E","test_object_en":"Bonded metal anchors E","methodology":"Odporność na moment niszczący Zakres: (1 - 1000) Nm Próba obciążenia momentem","methodology_en":"Resistance to breaking torque Range: (1 - 1000) Nm Torque loading test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na moment niszczący Zakres: (1 - 1000) Nm Próba obciążenia momentem","reference":"EAD 330499-xx-0601","norm_bases":["EAD 330499-xx-0601"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łączniki metalowe wklejane E Odporność na moment niszczący Zakres: (1 - 1000) Nm Próba obciążenia momentem EAD 330499-xx-0601 Laczniki metalowe wklejane E Odpornosc na moment niszczacy Zakres: (1 - 1000) Nm Proba obciazenia momentem EAD 330499-xx-0601","categories":["materials"],"row_index":808,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Bonded metal anchors E Resistance to breaking torque Range: (1 - 1000) Nm Torque loading test EAD 330499-xx-0601","search_zh":"植筋用金属锚固件 E EAD 330499-xx-0601","test_object_zh":"植筋用金属锚固件 E"},{"_id":"6a5a55f19af9f73f3825123d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Łączniki tworzywowo-metalowe E","test_object_en":"Plastic-metal fasteners E","methodology":"Nośność na wyrywanie z podłoża betonowego pełnego i z otworami oraz podłoża murowego pełnego i z otworami. Zakres: (1 - 50) kN Próba rozciągania","methodology_en":"Pull-out load-bearing capacity from solid and perforated concrete substrate and from solid and perforated masonry substrate. Range: (1 - 50) kN Tensile test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność na wyrywanie z podłoża betonowego pełnego i z otworami oraz podłoża murowego pełnego i z otworami. Zakres: (1 - 50) kN Próba rozciągania","reference":"EAD 330284-xx-0604+TR64","norm_bases":["EAD 330284-xx-0604+TR64"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łączniki tworzywowo-metalowe E Nośność na wyrywanie z podłoża betonowego pełnego i z otworami oraz podłoża murowego pełnego i z otworami. Zakres: (1 - 50) kN Próba rozciągania EAD 330284-xx-0604+TR64 Laczniki tworzywowo-metalowe E Nosnosc na wyrywanie z podloza betonowego pelnego i z otworami oraz podloza murowego pelnego i z otworami. Zakres: (1 - 50) kN Proba rozciagania EAD 330284-xx-0604+TR64","categories":["materials","construction"],"row_index":809,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic-metal fasteners E Pull-out load-bearing capacity from solid and perforated concrete substrate and from solid and perforated masonry substrate. Range: (1 - 50) kN Tensile test EAD 330284-xx-0604+TR64"},{"_id":"6a5a55f19af9f73f3825123e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Pręty zbrojeniowe: wklejane do nowych konstrukcji E","test_object_en":"Reinforcing bars: bonded-in in new structures E","methodology":"Nośność na ścinanie spoiny klejowej: beton zwykły, beton lekki Zakres: (1 - 900) kN Próba wyrywania","methodology_en":"Shear load-bearing capacity of the adhesive joint: normal-weight concrete, lightweight concrete Range: (1 - 900) kN Pull-out test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność na ścinanie spoiny klejowej: beton zwykły, beton lekki Zakres: (1 - 900) kN Próba wyrywania","reference":"EAD 330087-xx-0601","norm_bases":["EAD 330087-xx-0601"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pręty zbrojeniowe: wklejane do nowych konstrukcji E Nośność na ścinanie spoiny klejowej: beton zwykły, beton lekki Zakres: (1 - 900) kN Próba wyrywania EAD 330087-xx-0601 Prety zbrojeniowe: wklejane do nowych konstrukcji E Nosnosc na scinanie spoiny klejowej: beton zwykly, beton lekki Zakres: (1 - 900) kN Proba wyrywania EAD 330087-xx-0601","categories":["construction"],"row_index":810,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Reinforcing bars: bonded-in in new structures E Shear load-bearing capacity of the adhesive joint: normal-weight concrete, lightweight concrete Range: (1 - 900) kN Pull-out test EAD 330087-xx-0601","search_zh":"配筋钢筋：植入新结构 E EAD 330087-xx-0601","test_object_zh":"配筋钢筋：植入新结构 E"},{"_id":"6a5a55f19af9f73f3825123f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Pręty zbrojeniowe: wklejane do nowych konstrukcji E","test_object_en":"Reinforcing bars: bonded-in in new structures E","methodology":"Zdolność na zamocowanie z maksymalną głębokością Zakres: (0,5 - 2,5) m Ocena wizualna","methodology_en":"Fastening capability with maximum depth Range: (0,5 - 2,5) m Visual assessment","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność na zamocowanie z maksymalną głębokością Zakres: (0,5 - 2,5) m Ocena wizualna","reference":"EAD 330087-xx-0601","norm_bases":["EAD 330087-xx-0601"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pręty zbrojeniowe: wklejane do nowych konstrukcji E Zdolność na zamocowanie z maksymalną głębokością Zakres: (0,5 - 2,5) m Ocena wizualna EAD 330087-xx-0601 Prety zbrojeniowe: wklejane do nowych konstrukcji E Zdolnosc na zamocowanie z maksymalna glebokoscia Zakres: (0,5 - 2,5) m Ocena wizualna EAD 330087-xx-0601","categories":["other"],"row_index":811,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Reinforcing bars: bonded-in in new structures E Fastening capability with maximum depth Range: (0,5 - 2,5) m Visual assessment EAD 330087-xx-0601","search_zh":"配筋钢筋：植入新结构 E EAD 330087-xx-0601","test_object_zh":"配筋钢筋：植入新结构 E"},{"_id":"6a5a55f19af9f73f38251240","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Pręty zbrojeniowe: wklejane do nowych konstrukcji E","test_object_en":"Reinforcing bars: bonded-in in new structures E","methodology":"Nośność spoiny klejowej w różnych warunkach kondycjonowania Zakres: (1 - 900) kN Próba ścinania","methodology_en":"Load-bearing capacity of the adhesive joint under various conditioning conditions Range: (1 - 900) kN Shear test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność spoiny klejowej w różnych warunkach kondycjonowania Zakres: (1 - 900) kN Próba ścinania","reference":"EAD 330087-xx-0601","norm_bases":["EAD 330087-xx-0601"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pręty zbrojeniowe: wklejane do nowych konstrukcji E Nośność spoiny klejowej w różnych warunkach kondycjonowania Zakres: (1 - 900) kN Próba ścinania EAD 330087-xx-0601 Prety zbrojeniowe: wklejane do nowych konstrukcji E Nosnosc spoiny klejowej w roznych warunkach kondycjonowania Zakres: (1 - 900) kN Proba scinania EAD 330087-xx-0601","categories":["other"],"row_index":812,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Reinforcing bars: bonded-in in new structures E Load-bearing capacity of the adhesive joint under various conditioning conditions Range: (1 - 900) kN Shear test EAD 330087-xx-0601","search_zh":"配筋钢筋：植入新结构 E EAD 330087-xx-0601","test_object_zh":"配筋钢筋：植入新结构 E"},{"_id":"6a5a55f19af9f73f38251241","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Nakrętki metryczne E","test_object_en":"Metric nuts E","methodology":"Nośność nakrętek Zakres: (1 - 100) kN Ocena wizualna po próbie obciążenia","methodology_en":"Load-bearing capacity of nuts Range: (1 - 100) kN Visual assessment after the load test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność nakrętek Zakres: (1 - 100) kN Ocena wizualna po próbie obciążenia","reference":"PN-EN ISO 898-2","norm_bases":["PN-EN ISO 898-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Nakrętki metryczne E Nośność nakrętek Zakres: (1 - 100) kN Ocena wizualna po próbie obciążenia PN-EN ISO 898-2 Nakretki metryczne E Nosnosc nakretek Zakres: (1 - 100) kN Ocena wizualna po probie obciazenia PN-EN ISO 898-2","categories":["other"],"row_index":813,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Metric nuts E Load-bearing capacity of nuts Range: (1 - 100) kN Visual assessment after the load test PN-EN ISO 898-2"},{"_id":"6a5a55f19af9f73f38251242","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty sufitów podwieszanych E","test_object_en":"Suspended ceiling panels E","methodology":"Wymiary geometryczne liniowe Zakres: (0,1 - 3) m","methodology_en":"Linear geometric dimensions Range: (0,1 - 3) m","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary geometryczne liniowe Zakres: (0,1 - 3) m","reference":"PN-EN 13964","norm_bases":["PN-EN 13964"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty sufitów podwieszanych E Wymiary geometryczne liniowe Zakres: (0,1 - 3) m PN-EN 13964 Plyty sufitow podwieszanych E Wymiary geometryczne liniowe Zakres: (0,1 - 3) m PN-EN 13964","categories":["other"],"row_index":814,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Suspended ceiling panels E Linear geometric dimensions Range: (0,1 - 3) m PN-EN 13964"},{"_id":"6a5a55f19af9f73f38251243","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty sufitów podwieszanych E","test_object_en":"Suspended ceiling panels E","methodology":"Wytrzymałość na zginanie Zakres: (0,5 - 10) kN Próba zginania","methodology_en":"Flexural strength Range: (0,5 - 10) kN Bending test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na zginanie Zakres: (0,5 - 10) kN Próba zginania","reference":"PN-EN 13964, Załącznik F „N”","norm_bases":["PN-EN 13964, Załącznik F „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty sufitów podwieszanych E Wytrzymałość na zginanie Zakres: (0,5 - 10) kN Próba zginania PN-EN 13964, Załącznik F „N” Plyty sufitow podwieszanych E Wytrzymalosc na zginanie Zakres: (0,5 - 10) kN Proba zginania PN-EN 13964, Zalacznik F „N”","categories":["other"],"row_index":815,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Suspended ceiling panels E Flexural strength Range: (0,5 - 10) kN Bending test PN-EN 13964, Załącznik F „N”"},{"_id":"6a5a55f19af9f73f38251244","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Pomosty, stopnie szerokie, stopnie wąskie E","test_object_en":"Platforms, wide steps, narrow steps E","methodology":"Odkształcenie pod obciążeniem statycznym Zakres: (0,1 - 100) mm Przemieszczenie pod obciążeniem","methodology_en":"Deformation under static load Range: (0,1 - 100) mm Displacement under load","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odkształcenie pod obciążeniem statycznym Zakres: (0,1 - 100) mm Przemieszczenie pod obciążeniem","reference":"PN-EN 516 „N”","norm_bases":["PN-EN 516 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomosty, stopnie szerokie, stopnie wąskie E Odkształcenie pod obciążeniem statycznym Zakres: (0,1 - 100) mm Przemieszczenie pod obciążeniem PN-EN 516 „N” Pomosty, stopnie szerokie, stopnie waskie E Odksztalcenie pod obciazeniem statycznym Zakres: (0,1 - 100) mm Przemieszczenie pod obciazeniem PN-EN 516 „N”","categories":["other"],"row_index":816,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Platforms, wide steps, narrow steps E Deformation under static load Range: (0,1 - 100) mm Displacement under load PN-EN 516 „N”"},{"_id":"6a5a55f19af9f73f38251245","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Pręty zbrojeniowe: wklejane do napraw konstrukcji E","test_object_en":"Reinforcing bars: post-installed bonded bars for structural repairs E","methodology":"Nośność na wyrywanie: beton zwykły, beton lekki Zakres: (1 - 900) kN Próba wyrywania","methodology_en":"Pull-out load-bearing capacity: normal-weight concrete, lightweight concrete Range: (1 - 900) kN Pull-out test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność na wyrywanie: beton zwykły, beton lekki Zakres: (1 - 900) kN Próba wyrywania","reference":"PN-EN 1881","norm_bases":["PN-EN 1881"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pręty zbrojeniowe: wklejane do napraw konstrukcji E Nośność na wyrywanie: beton zwykły, beton lekki Zakres: (1 - 900) kN Próba wyrywania PN-EN 1881 Prety zbrojeniowe: wklejane do napraw konstrukcji E Nosnosc na wyrywanie: beton zwykly, beton lekki Zakres: (1 - 900) kN Proba wyrywania PN-EN 1881","categories":["construction"],"row_index":817,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Reinforcing bars: post-installed bonded bars for structural repairs E Pull-out load-bearing capacity: normal-weight concrete, lightweight concrete Range: (1 - 900) kN Pull-out test PN-EN 1881"},{"_id":"6a5a55f19af9f73f38251246","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Pręty zbrojeniowe: wklejane do napraw konstrukcji E","test_object_en":"Reinforcing bars: post-installed bonded bars for structural repairs E","methodology":"Właściwości wytrzymałościowe: Zakres: do 1000 kN Próba rozciągania","methodology_en":"Strength properties: Range: up to 1000 kN Tensile test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Właściwości wytrzymałościowe: Zakres: do 1000 kN Próba rozciągania","reference":"PN-EN ISO 6892-1 Metoda B","norm_bases":["PN-EN ISO 6892-1 Metoda B"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pręty zbrojeniowe: wklejane do napraw konstrukcji E Właściwości wytrzymałościowe: Zakres: do 1000 kN Próba rozciągania PN-EN ISO 6892-1 Metoda B Prety zbrojeniowe: wklejane do napraw konstrukcji E Wlasciwosci wytrzymalosciowe: Zakres: do 1000 kN Proba rozciagania PN-EN ISO 6892-1 Metoda B","categories":["other"],"row_index":818,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Reinforcing bars: post-installed bonded bars for structural repairs E Strength properties: Range: up to 1000 kN Tensile test PN-EN ISO 6892-1 Metoda B","methodology_zh":"强度性能 范围：至 1000 kN 拉伸试验","search_zh":"强度性能 范围：至 1000 kN 拉伸试验 PN-EN ISO 6892-1 Metoda B"},{"_id":"6a5a55f19af9f73f38251247","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Pręty zbrojeniowe: wklejane do nowych konstrukcji E","test_object_en":"Reinforcing bars: bonded-in in new structures E","methodology":"Właściwości wytrzymałościowe: Zakres: do 1000 kN Próba rozciągania","methodology_en":"Strength properties: Range: up to 1000 kN Tensile test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Właściwości wytrzymałościowe: Zakres: do 1000 kN Próba rozciągania","reference":"PN-EN ISO 6892-1","norm_bases":["PN-EN ISO 6892-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pręty zbrojeniowe: wklejane do nowych konstrukcji E Właściwości wytrzymałościowe: Zakres: do 1000 kN Próba rozciągania PN-EN ISO 6892-1 Prety zbrojeniowe: wklejane do nowych konstrukcji E Wlasciwosci wytrzymalosciowe: Zakres: do 1000 kN Proba rozciagania PN-EN ISO 6892-1","categories":["other"],"row_index":819,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Reinforcing bars: bonded-in in new structures E Strength properties: Range: up to 1000 kN Tensile test PN-EN ISO 6892-1","methodology_zh":"强度性能 范围：至 1000 kN 拉伸试验","search_zh":"配筋钢筋：植入新结构 E 强度性能 范围：至 1000 kN 拉伸试验 PN-EN ISO 6892-1","test_object_zh":"配筋钢筋：植入新结构 E"},{"_id":"6a5a55f19af9f73f38251248","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stal E","test_object_en":"Steel E","methodology":"Twardość Vickersa Zakres: (5 - 30) HV Metoda Vickersa","methodology_en":"Vickers hardness Range: (5 - 30) HV Vickers method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Twardość Vickersa Zakres: (5 - 30) HV Metoda Vickersa","reference":"PN-EN ISO 6507-1","norm_bases":["PN-EN ISO 6507-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stal E Twardość Vickersa Zakres: (5 - 30) HV Metoda Vickersa PN-EN ISO 6507-1 Stal E Twardosc Vickersa Zakres: (5 - 30) HV Metoda Vickersa PN-EN ISO 6507-1","categories":["materials"],"row_index":820,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Steel E Vickers hardness Range: (5 - 30) HV Vickers method PN-EN ISO 6507-1"},{"_id":"6a5a55f19af9f73f38251249","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stal E","test_object_en":"Steel E","methodology":"Właściwości wytrzymałościowe: Zakres: siła (1 - 1000) kN Próba rozciągania","methodology_en":"Strength properties: Range: force (1 - 1000) kN Tensile test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Właściwości wytrzymałościowe: Zakres: siła (1 - 1000) kN Próba rozciągania","reference":"PN-EN ISO 6892-1","norm_bases":["PN-EN ISO 6892-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stal E Właściwości wytrzymałościowe: Zakres: siła (1 - 1000) kN Próba rozciągania PN-EN ISO 6892-1 Stal E Wlasciwosci wytrzymalosciowe: Zakres: sila (1 - 1000) kN Proba rozciagania PN-EN ISO 6892-1","categories":["materials"],"row_index":821,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Steel E Strength properties: Range: force (1 - 1000) kN Tensile test PN-EN ISO 6892-1"},{"_id":"6a5a55f19af9f73f3825124a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stal zbrojeniowa, siatki zgrzewane E","test_object_en":"Reinforcing steel, welded fabric E","methodology":"Długość, szerokość maty, rozstaw i wysięgi prętów oraz średnice prętów, Zakres: do 3000 mm","methodology_en":"Length, width of the mesh, spacing and overhangs of the bars and bar diameters, Range: up to 3000 mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Długość, szerokość maty, rozstaw i wysięgi prętów oraz średnice prętów, Zakres: do 3000 mm","reference":"PN-EN ISO 15630-2","norm_bases":["PN-EN ISO 15630-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stal zbrojeniowa, siatki zgrzewane E Długość, szerokość maty, rozstaw i wysięgi prętów oraz średnice prętów, Zakres: do 3000 mm PN-EN ISO 15630-2 Stal zbrojeniowa, siatki zgrzewane E Dlugosc, szerokosc maty, rozstaw i wysiegi pretow oraz srednice pretow, Zakres: do 3000 mm PN-EN ISO 15630-2","categories":["materials"],"row_index":822,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Reinforcing steel, welded fabric E Length, width of the mesh, spacing and overhangs of the bars and bar diameters, Range: up to 3000 mm PN-EN ISO 15630-2","search_zh":"配筋用钢、焊接钢筋网 E PN-EN ISO 15630-2","test_object_zh":"配筋用钢、焊接钢筋网 E"},{"_id":"6a5a55f19af9f73f3825124b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stal zbrojeniowa, siatki zgrzewane E","test_object_en":"Reinforcing steel, welded fabric E","methodology":"Nośność złącza zgrzewanego na ścinanie Zakres: (0,5 - 100) kN Próba ścinania","methodology_en":"Shear load-bearing capacity of the resistance welded joint Range: (0,5 - 100) kN Shear test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność złącza zgrzewanego na ścinanie Zakres: (0,5 - 100) kN Próba ścinania","reference":"PN-EN ISO 15630-2","norm_bases":["PN-EN ISO 15630-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stal zbrojeniowa, siatki zgrzewane E Nośność złącza zgrzewanego na ścinanie Zakres: (0,5 - 100) kN Próba ścinania PN-EN ISO 15630-2 Stal zbrojeniowa, siatki zgrzewane E Nosnosc zlacza zgrzewanego na scinanie Zakres: (0,5 - 100) kN Proba scinania PN-EN ISO 15630-2","categories":["materials"],"row_index":823,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Reinforcing steel, welded fabric E Shear load-bearing capacity of the resistance welded joint Range: (0,5 - 100) kN Shear test PN-EN ISO 15630-2","search_zh":"配筋用钢、焊接钢筋网 E PN-EN ISO 15630-2","test_object_zh":"配筋用钢、焊接钢筋网 E"},{"_id":"6a5a55f19af9f73f3825124c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stal zbrojeniowa, siatki zgrzewane E","test_object_en":"Reinforcing steel, welded fabric E","methodology":"Odporność zmęczeniowa przy obciążeniu osiowym Zakres: (5 - 16) mm Próba zmęczeniowa","methodology_en":"Fatigue resistance under axial loading Range: (5 - 16) mm Fatigue test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność zmęczeniowa przy obciążeniu osiowym Zakres: (5 - 16) mm Próba zmęczeniowa","reference":"PN-EN ISO 15630-1 PN-EN ISO 15630-2","norm_bases":["PN-EN ISO 15630-1 PN-EN ISO 15630-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stal zbrojeniowa, siatki zgrzewane E Odporność zmęczeniowa przy obciążeniu osiowym Zakres: (5 - 16) mm Próba zmęczeniowa PN-EN ISO 15630-1 PN-EN ISO 15630-2 Stal zbrojeniowa, siatki zgrzewane E Odpornosc zmeczeniowa przy obciazeniu osiowym Zakres: (5 - 16) mm Proba zmeczeniowa PN-EN ISO 15630-1 PN-EN ISO 15630-2","categories":["materials"],"row_index":824,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Reinforcing steel, welded fabric E Fatigue resistance under axial loading Range: (5 - 16) mm Fatigue test PN-EN ISO 15630-1 PN-EN ISO 15630-2","search_zh":"配筋用钢、焊接钢筋网 E PN-EN ISO 15630-1 PN-EN ISO 15630-2","test_object_zh":"配筋用钢、焊接钢筋网 E"},{"_id":"6a5a55f19af9f73f3825124d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stal zbrojeniowa, siatki zgrzewane E","test_object_en":"Reinforcing steel, welded fabric E","methodology":"Właściwości wytrzymałościowe: Zakres: do 1000 kN Próba rozciągania","methodology_en":"Strength properties: Range: up to 1000 kN Tensile test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Właściwości wytrzymałościowe: Zakres: do 1000 kN Próba rozciągania","reference":"PN-EN ISO 6892-1","norm_bases":["PN-EN ISO 6892-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stal zbrojeniowa, siatki zgrzewane E Właściwości wytrzymałościowe: Zakres: do 1000 kN Próba rozciągania PN-EN ISO 6892-1 Stal zbrojeniowa, siatki zgrzewane E Wlasciwosci wytrzymalosciowe: Zakres: do 1000 kN Proba rozciagania PN-EN ISO 6892-1","categories":["materials"],"row_index":825,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Reinforcing steel, welded fabric E Strength properties: Range: up to 1000 kN Tensile test PN-EN ISO 6892-1","search_zh":"配筋用钢、焊接钢筋网 E 强度性能 范围：至 1000 kN 拉伸试验 PN-EN ISO 6892-1","test_object_zh":"配筋用钢、焊接钢筋网 E","methodology_zh":"强度性能 范围：至 1000 kN 拉伸试验"},{"_id":"6a5a55f19af9f73f3825124e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stal zbrojeniowa, siatki zgrzewane E","test_object_en":"Reinforcing steel, welded fabric E","methodology":"Zdolność na zginanie Zakres: średnica (1 - 16) mm Ocena wizualna","methodology_en":"Bending capability Range: diameter (1 - 16) mm Visual assessment","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność na zginanie Zakres: średnica (1 - 16) mm Ocena wizualna","reference":"PN-EN ISO 15630-2","norm_bases":["PN-EN ISO 15630-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stal zbrojeniowa, siatki zgrzewane E Zdolność na zginanie Zakres: średnica (1 - 16) mm Ocena wizualna PN-EN ISO 15630-2 Stal zbrojeniowa, siatki zgrzewane E Zdolnosc na zginanie Zakres: srednica (1 - 16) mm Ocena wizualna PN-EN ISO 15630-2","categories":["materials"],"row_index":826,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Reinforcing steel, welded fabric E Bending capability Range: diameter (1 - 16) mm Visual assessment PN-EN ISO 15630-2","search_zh":"配筋用钢、焊接钢筋网 E PN-EN ISO 15630-2","test_object_zh":"配筋用钢、焊接钢筋网 E"},{"_id":"6a5a55f19af9f73f3825124f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Trójwymiarowe łączniki stalowe E","test_object_en":"Three-dimensional steel connectors E","methodology":"Wytrzymałość gwoździ Zakres: (0,1 - 50) kN Próba rozciągania","methodology_en":"Strength of nails Range: (0,1 - 50) kN Tensile test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość gwoździ Zakres: (0,1 - 50) kN Próba rozciągania","reference":"PN-EN 1382","norm_bases":["PN-EN 1382"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Trójwymiarowe łączniki stalowe E Wytrzymałość gwoździ Zakres: (0,1 - 50) kN Próba rozciągania PN-EN 1382 Trojwymiarowe laczniki stalowe E Wytrzymalosc gwozdzi Zakres: (0,1 - 50) kN Proba rozciagania PN-EN 1382","categories":["materials"],"row_index":827,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Three-dimensional steel connectors E Strength of nails Range: (0,1 - 50) kN Tensile test PN-EN 1382"},{"_id":"6a5a55f19af9f73f38251250","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zaprawy E","test_object_en":"Mortars E","methodology":"Wytrzymałość na ściskanie Zakres: (5 - 3000) kN Próba ściskania","methodology_en":"Compressive strength Range: (5 - 3000) kN Compression test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie Zakres: (5 - 3000) kN Próba ściskania","reference":"PN-EN 1015-11","norm_bases":["PN-EN 1015-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy E Wytrzymałość na ściskanie Zakres: (5 - 3000) kN Próba ściskania PN-EN 1015-11 Zaprawy E Wytrzymalosc na sciskanie Zakres: (5 - 3000) kN Proba sciskania PN-EN 1015-11","categories":["other"],"row_index":828,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mortars E Compressive strength Range: (5 - 3000) kN Compression test PN-EN 1015-11"},{"_id":"6a5a55f19af9f73f38251251","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zaprawy E","test_object_en":"Mortars E","methodology":"Wytrzymałość na zginanie Zakres: (0,1 - 100) kN Próba zginania","methodology_en":"Flexural strength Range: (0,1 - 100) kN Bending test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na zginanie Zakres: (0,1 - 100) kN Próba zginania","reference":"PN-EN 1015-11","norm_bases":["PN-EN 1015-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy E Wytrzymałość na zginanie Zakres: (0,1 - 100) kN Próba zginania PN-EN 1015-11 Zaprawy E Wytrzymalosc na zginanie Zakres: (0,1 - 100) kN Proba zginania PN-EN 1015-11","categories":["other"],"row_index":829,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mortars E Flexural strength Range: (0,1 - 100) kN Bending test PN-EN 1015-11"},{"_id":"6a5a55f19af9f73f38251252","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby ogniochronne reaktywne","test_object_en":"Reactive fire protection products","methodology":"Oddziaływanie zmiennych warunków środowiskowych: X, Y, Z1, Z2","methodology_en":"Effect of varying environmental conditions: X, Y, Z1, Z2","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Oddziaływanie zmiennych warunków środowiskowych: X, Y, Z1, Z2","reference":"EAD 350402-00-1106","norm_bases":["EAD 350402-00-1106"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby ogniochronne reaktywne Oddziaływanie zmiennych warunków środowiskowych: X, Y, Z1, Z2 EAD 350402-00-1106 Wyroby ogniochronne reaktywne Oddzialywanie zmiennych warunkow srodowiskowych: X, Y, Z1, Z2 EAD 350402-00-1106","categories":["environment"],"row_index":830,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Reactive fire protection products Effect of varying environmental conditions: X, Y, Z1, Z2 EAD 350402-00-1106","search_zh":"膨胀型防火制品 EAD 350402-00-1106","test_object_zh":"膨胀型防火制品"},{"_id":"6a5a55f19af9f73f38251253","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych","test_object_en":"Plastic products","methodology":"Wytrzymałość na rozdzieranie Zakres: do 10 kN próbka kątowa","methodology_en":"Tear strength Range: up to 10 kN angle test piece","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na rozdzieranie Zakres: do 10 kN próbka kątowa","reference":"PN-ISO 34-1:2007","norm_bases":["PN-ISO 34-1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych Wytrzymałość na rozdzieranie Zakres: do 10 kN próbka kątowa PN-ISO 34-1:2007 Wyroby z tworzyw sztucznych Wytrzymalosc na rozdzieranie Zakres: do 10 kN probka katowa PN-ISO 34-1:2007","categories":["other"],"row_index":831,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products Tear strength Range: up to 10 kN angle test piece PN-ISO 34-1:2007","search_zh":"塑料制品 PN-ISO 34-1:2007","test_object_zh":"塑料制品"},{"_id":"6a5a55f19af9f73f38251254","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych","test_object_en":"Plastic products","methodology":"Odporność na działanie wilgotnej atmosfery zawierającej SO 2","methodology_en":"Resistance to humid atmospheres containing SO 2","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie wilgotnej atmosfery zawierającej SO 2","reference":"PN-EN ISO 3231:2000","norm_bases":["PN-EN ISO 3231:2000"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych Odporność na działanie wilgotnej atmosfery zawierającej SO 2 PN-EN ISO 3231:2000 Wyroby z tworzyw sztucznych Odpornosc na dzialanie wilgotnej atmosfery zawierajacej SO 2 PN-EN ISO 3231:2000","categories":["other"],"row_index":832,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products Resistance to humid atmospheres containing SO 2 PN-EN ISO 3231:2000","search_zh":"塑料制品 含 SO2 潮湿气氛的耐受性 PN-EN ISO 3231:2000","test_object_zh":"塑料制品","methodology_zh":"含 SO2 潮湿气氛的耐受性"},{"_id":"6a5a55f19af9f73f38251255","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Powłoki","test_object_en":"Coatings","methodology":"Skuteczność w powłoce środków ochrony powłok przed grzybami pleśniowymi","methodology_en":"In-film efficacy of film preservatives against mould fungi","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność w powłoce środków ochrony powłok przed grzybami pleśniowymi","reference":"EN 15457: 2014 +PB LM-004/02/03-2015","norm_bases":["EN 15457: 2014 +PB LM-004/02/03-2015"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki Skuteczność w powłoce środków ochrony powłok przed grzybami pleśniowymi EN 15457: 2014 +PB LM-004/02/03-2015 Powloki Skutecznosc w powloce srodkow ochrony powlok przed grzybami plesniowymi EN 15457: 2014 +PB LM-004/02/03-2015","categories":["other"],"row_index":833,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coatings In-film efficacy of film preservatives against mould fungi EN 15457: 2014 +PB LM-004/02/03-2015"},{"_id":"6a5a55f19af9f73f38251256","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Powłoki","test_object_en":"Coatings","methodology":"Skuteczność w powłoce środków ochrony powłok przed glonami","methodology_en":"In-film efficacy of film preservatives against algae","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność w powłoce środków ochrony powłok przed glonami","reference":"EN 15458:2014 +PB LM-005/02/01-2015","norm_bases":["EN 15458:2014 +PB LM-005/02/01-2015"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki Skuteczność w powłoce środków ochrony powłok przed glonami EN 15458:2014 +PB LM-005/02/01-2015 Powloki Skutecznosc w powloce srodkow ochrony powlok przed glonami EN 15458:2014 +PB LM-005/02/01-2015","categories":["other"],"row_index":834,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coatings In-film efficacy of film preservatives against algae EN 15458:2014 +PB LM-005/02/01-2015"},{"_id":"6a5a55f19af9f73f38251257","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Środki ochrony drewna","test_object_en":"Wood preservatives","methodology":"Własności zabezpieczające środków ochrony drewna przed grzybami pleśniowymi w zastosowaniu do drewna i materiałów drewnopochodnych","methodology_en":"Protective properties of wood preservatives against mould fungi for use on wood and wood-based materials","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Własności zabezpieczające środków ochrony drewna przed grzybami pleśniowymi w zastosowaniu do drewna i materiałów drewnopochodnych","reference":"LD-006/2/01-1999","norm_bases":["LD-006/2/01-1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środki ochrony drewna Własności zabezpieczające środków ochrony drewna przed grzybami pleśniowymi w zastosowaniu do drewna i materiałów drewnopochodnych LD-006/2/01-1999 Srodki ochrony drewna Wlasnosci zabezpieczajace srodkow ochrony drewna przed grzybami plesniowymi w zastosowaniu do drewna i materialow drewnopochodnych LD-006/2/01-1999","categories":["materials"],"row_index":835,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wood preservatives Protective properties of wood preservatives against mould fungi for use on wood and wood-based materials LD-006/2/01-1999"},{"_id":"6a5a55f19af9f73f38251258","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kleje, wyroby z połączeniami klejowymi","test_object_en":"Adhesives, products with adhesive joints","methodology":"Czas otwarty Zakres: do 16 kN Metoda pull off","methodology_en":"Open time Range: up to 16 kN Pull-off method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Czas otwarty Zakres: do 16 kN Metoda pull off","reference":"PN-EN 1346:2008","norm_bases":["PN-EN 1346:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kleje, wyroby z połączeniami klejowymi Czas otwarty Zakres: do 16 kN Metoda pull off PN-EN 1346:2008 Kleje, wyroby z polaczeniami klejowymi Czas otwarty Zakres: do 16 kN Metoda pull off PN-EN 1346:2008","categories":["other"],"row_index":836,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Adhesives, products with adhesive joints Open time Range: up to 16 kN Pull-off method PN-EN 1346:2008","search_zh":"胶粘剂、含胶接接头的制品 PN-EN 1346:2008","test_object_zh":"胶粘剂、含胶接接头的制品"},{"_id":"6a5a55f19af9f73f38251259","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kleje, wyroby z połączeniami klejowymi","test_object_en":"Adhesives, products with adhesive joints","methodology":"Odkształcenie poprzeczne","methodology_en":"Transverse deformation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odkształcenie poprzeczne","reference":"PN-EN 12002:2010","norm_bases":["PN-EN 12002:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kleje, wyroby z połączeniami klejowymi Odkształcenie poprzeczne PN-EN 12002:2010 Kleje, wyroby z polaczeniami klejowymi Odksztalcenie poprzeczne PN-EN 12002:2010","categories":["other"],"row_index":837,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Adhesives, products with adhesive joints Transverse deformation PN-EN 12002:2010","search_zh":"胶粘剂、含胶接接头的制品 横向变形 PN-EN 12002:2010","test_object_zh":"胶粘剂、含胶接接头的制品","methodology_zh":"横向变形"},{"_id":"6a5a55f19af9f73f3825125a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kleje, wyroby z połączeniami klejowymi","test_object_en":"Adhesives, products with adhesive joints","methodology":"Przyczepność po cyklach zamrażania i rozmrażania Zakres: do 16 kN Metoda pull off","methodology_en":"Adhesion after freeze-thaw cycles Range: up to 16 kN Pull off method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przyczepność po cyklach zamrażania i rozmrażania Zakres: do 16 kN Metoda pull off","reference":"PN-EN 1348:2008 „N”","norm_bases":["PN-EN 1348:2008 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kleje, wyroby z połączeniami klejowymi Przyczepność po cyklach zamrażania i rozmrażania Zakres: do 16 kN Metoda pull off PN-EN 1348:2008 „N” Kleje, wyroby z polaczeniami klejowymi Przyczepnosc po cyklach zamrazania i rozmrazania Zakres: do 16 kN Metoda pull off PN-EN 1348:2008 „N”","categories":["other"],"row_index":838,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Adhesives, products with adhesive joints Adhesion after freeze-thaw cycles Range: up to 16 kN Pull off method PN-EN 1348:2008 „N”","search_zh":"胶粘剂、含胶接接头的制品 PN-EN 1348:2008 „N”","test_object_zh":"胶粘剂、含胶接接头的制品"},{"_id":"6a5a55f19af9f73f3825125b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kleje, wyroby z połączeniami klejowymi","test_object_en":"Adhesives, products with adhesive joints","methodology":"Przyczepność po starzeniu termicznym Zakres: do 16 kN Metoda pull off","methodology_en":"Adhesion after thermal ageing Range: up to 16 kN Pull off method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przyczepność po starzeniu termicznym Zakres: do 16 kN Metoda pull off","reference":"PN-EN 1348:2008 „N”","norm_bases":["PN-EN 1348:2008 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kleje, wyroby z połączeniami klejowymi Przyczepność po starzeniu termicznym Zakres: do 16 kN Metoda pull off PN-EN 1348:2008 „N” Kleje, wyroby z polaczeniami klejowymi Przyczepnosc po starzeniu termicznym Zakres: do 16 kN Metoda pull off PN-EN 1348:2008 „N”","categories":["other"],"row_index":839,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Adhesives, products with adhesive joints Adhesion after thermal ageing Range: up to 16 kN Pull off method PN-EN 1348:2008 „N”","search_zh":"胶粘剂、含胶接接头的制品 PN-EN 1348:2008 „N”","test_object_zh":"胶粘剂、含胶接接头的制品"},{"_id":"6a5a55f19af9f73f3825125c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kleje, wyroby z połączeniami klejowymi","test_object_en":"Adhesives, products with adhesive joints","methodology":"Przyczepność po zanurzeniu w wodzie Zakres: do 16 kN Metoda pull off","methodology_en":"Adhesion after water immersion Range: up to 16 kN Pull off method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przyczepność po zanurzeniu w wodzie Zakres: do 16 kN Metoda pull off","reference":"PN-EN 1348:2008 „N”","norm_bases":["PN-EN 1348:2008 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kleje, wyroby z połączeniami klejowymi Przyczepność po zanurzeniu w wodzie Zakres: do 16 kN Metoda pull off PN-EN 1348:2008 „N” Kleje, wyroby z polaczeniami klejowymi Przyczepnosc po zanurzeniu w wodzie Zakres: do 16 kN Metoda pull off PN-EN 1348:2008 „N”","categories":["other"],"row_index":840,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Adhesives, products with adhesive joints Adhesion after water immersion Range: up to 16 kN Pull off method PN-EN 1348:2008 „N”","search_zh":"胶粘剂、含胶接接头的制品 PN-EN 1348:2008 „N”","test_object_zh":"胶粘剂、含胶接接头的制品"},{"_id":"6a5a55f19af9f73f3825125d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kleje, wyroby z połączeniami klejowymi","test_object_en":"Adhesives, products with adhesive joints","methodology":"Przyczepność początkowa (wytrzymałość pierwotna) Zakres: do 16 kN Metoda pull off","methodology_en":"Initial adhesion (initial strength) Range: up to 16 kN Pull off method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przyczepność początkowa (wytrzymałość pierwotna) Zakres: do 16 kN Metoda pull off","reference":"PN-EN 1348:2008 „N”","norm_bases":["PN-EN 1348:2008 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kleje, wyroby z połączeniami klejowymi Przyczepność początkowa (wytrzymałość pierwotna) Zakres: do 16 kN Metoda pull off PN-EN 1348:2008 „N” Kleje, wyroby z polaczeniami klejowymi Przyczepnosc poczatkowa (wytrzymalosc pierwotna) Zakres: do 16 kN Metoda pull off PN-EN 1348:2008 „N”","categories":["other"],"row_index":841,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Adhesives, products with adhesive joints Initial adhesion (initial strength) Range: up to 16 kN Pull off method PN-EN 1348:2008 „N”","search_zh":"胶粘剂、含胶接接头的制品 PN-EN 1348:2008 „N”","test_object_zh":"胶粘剂、含胶接接头的制品"},{"_id":"6a5a55f19af9f73f3825125e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kleje, wyroby z połączeniami klejowymi","test_object_en":"Adhesives, products with adhesive joints","methodology":"Spływ (poślizg)","methodology_en":"Sagging (slip)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Spływ (poślizg)","reference":"PN-EN 1308:2008","norm_bases":["PN-EN 1308:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kleje, wyroby z połączeniami klejowymi Spływ (poślizg) PN-EN 1308:2008 Kleje, wyroby z polaczeniami klejowymi Splyw (poslizg) PN-EN 1308:2008","categories":["other"],"row_index":842,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Adhesives, products with adhesive joints Sagging (slip) PN-EN 1308:2008","search_zh":"胶粘剂、含胶接接头的制品 PN-EN 1308:2008","test_object_zh":"胶粘剂、含胶接接头的制品"},{"_id":"6a5a55f19af9f73f3825125f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kleje, wyroby z połączeniami klejowymi","test_object_en":"Adhesives, products with adhesive joints","methodology":"Wytrzymałość na ścinanie po starzeniu termicznym Zakres: do 10 kN","methodology_en":"Shear strength after thermal ageing Range: up to 10 kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ścinanie po starzeniu termicznym Zakres: do 10 kN","reference":"PN-EN 1324:2008 „N”","norm_bases":["PN-EN 1324:2008 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kleje, wyroby z połączeniami klejowymi Wytrzymałość na ścinanie po starzeniu termicznym Zakres: do 10 kN PN-EN 1324:2008 „N” Kleje, wyroby z polaczeniami klejowymi Wytrzymalosc na scinanie po starzeniu termicznym Zakres: do 10 kN PN-EN 1324:2008 „N”","categories":["other"],"row_index":843,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Adhesives, products with adhesive joints Shear strength after thermal ageing Range: up to 10 kN PN-EN 1324:2008 „N”","search_zh":"胶粘剂、含胶接接头的制品 PN-EN 1324:2008 „N”","test_object_zh":"胶粘剂、含胶接接头的制品"},{"_id":"6a5a55f19af9f73f38251260","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kleje, wyroby z połączeniami klejowymi","test_object_en":"Adhesives, products with adhesive joints","methodology":"Wytrzymałość na ścinanie po zanurzeniu w wodzie Zakres: do 10 kN","methodology_en":"Shear strength after immersion in water Range: up to 10 kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ścinanie po zanurzeniu w wodzie Zakres: do 10 kN","reference":"PN-EN 1324:2008 „N”","norm_bases":["PN-EN 1324:2008 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kleje, wyroby z połączeniami klejowymi Wytrzymałość na ścinanie po zanurzeniu w wodzie Zakres: do 10 kN PN-EN 1324:2008 „N” Kleje, wyroby z polaczeniami klejowymi Wytrzymalosc na scinanie po zanurzeniu w wodzie Zakres: do 10 kN PN-EN 1324:2008 „N”","categories":["other"],"row_index":844,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Adhesives, products with adhesive joints Shear strength after immersion in water Range: up to 10 kN PN-EN 1324:2008 „N”","search_zh":"胶粘剂、含胶接接头的制品 PN-EN 1324:2008 „N”","test_object_zh":"胶粘剂、含胶接接头的制品"},{"_id":"6a5a55f19af9f73f38251261","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kleje, wyroby z połączeniami klejowymi","test_object_en":"Adhesives, products with adhesive joints","methodology":"Wytrzymałość na ścinanie początkowa Zakres: do 10 kN","methodology_en":"Initial shear strength Range: up to 10 kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ścinanie początkowa Zakres: do 10 kN","reference":"PN-EN 1324:2008 „N”","norm_bases":["PN-EN 1324:2008 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kleje, wyroby z połączeniami klejowymi Wytrzymałość na ścinanie początkowa Zakres: do 10 kN PN-EN 1324:2008 „N” Kleje, wyroby z polaczeniami klejowymi Wytrzymalosc na scinanie poczatkowa Zakres: do 10 kN PN-EN 1324:2008 „N”","categories":["other"],"row_index":845,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Adhesives, products with adhesive joints Initial shear strength Range: up to 10 kN PN-EN 1324:2008 „N”","search_zh":"胶粘剂、含胶接接头的制品 PN-EN 1324:2008 „N”","test_object_zh":"胶粘剂、含胶接接头的制品"},{"_id":"6a5a55f19af9f73f38251262","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kleje, wyroby z połączeniami klejowymi","test_object_en":"Adhesives, products with adhesive joints","methodology":"Wytrzymałość na ścinanie w podwyższonej temperaturze Zakres: do 10 kN","methodology_en":"Shear strength at elevated temperature Range: up to 10 kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ścinanie w podwyższonej temperaturze Zakres: do 10 kN","reference":"PN-EN 1324:2008 „N”","norm_bases":["PN-EN 1324:2008 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kleje, wyroby z połączeniami klejowymi Wytrzymałość na ścinanie w podwyższonej temperaturze Zakres: do 10 kN PN-EN 1324:2008 „N” Kleje, wyroby z polaczeniami klejowymi Wytrzymalosc na scinanie w podwyzszonej temperaturze Zakres: do 10 kN PN-EN 1324:2008 „N”","categories":["other"],"row_index":846,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Adhesives, products with adhesive joints Shear strength at elevated temperature Range: up to 10 kN PN-EN 1324:2008 „N”","search_zh":"胶粘剂、含胶接接头的制品 PN-EN 1324:2008 „N”","test_object_zh":"胶粘剂、含胶接接头的制品"},{"_id":"6a5a55f19af9f73f38251263","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kleje, wyroby z połączeniami klejowymi","test_object_en":"Adhesives, products with adhesive joints","methodology":"Wytrzymałość na ścinanie Zakres: do 10 kN","methodology_en":"Shear strength Range: up to 10 kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ścinanie Zakres: do 10 kN","reference":"PN-EN 12003:2008 „N”","norm_bases":["PN-EN 12003:2008 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kleje, wyroby z połączeniami klejowymi Wytrzymałość na ścinanie Zakres: do 10 kN PN-EN 12003:2008 „N” Kleje, wyroby z polaczeniami klejowymi Wytrzymalosc na scinanie Zakres: do 10 kN PN-EN 12003:2008 „N”","categories":["other"],"row_index":847,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Adhesives, products with adhesive joints Shear strength Range: up to 10 kN PN-EN 12003:2008 „N”","search_zh":"胶粘剂、含胶接接头的制品 PN-EN 12003:2008 „N”","test_object_zh":"胶粘剂、含胶接接头的制品"},{"_id":"6a5a55f19af9f73f38251264","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby hydroizolacyjne rolowe","test_object_en":"Roll waterproofing products","methodology":"Wytrzymałość na rozdzieranie Zakres: do 10 kN","methodology_en":"Tear resistance Range: up to 10 kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na rozdzieranie Zakres: do 10 kN","reference":"PN-ISO 34-1:2007","norm_bases":["PN-ISO 34-1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby hydroizolacyjne rolowe Wytrzymałość na rozdzieranie Zakres: do 10 kN PN-ISO 34-1:2007 Wyroby hydroizolacyjne rolowe Wytrzymalosc na rozdzieranie Zakres: do 10 kN PN-ISO 34-1:2007","categories":["other"],"row_index":848,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Roll waterproofing products Tear resistance Range: up to 10 kN PN-ISO 34-1:2007"},{"_id":"6a5a55f19af9f73f38251265","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych","test_object_en":"Plastic products","methodology":"Właściwości mechaniczne przy rozciąganiu – moduł sprężystości Zakres: do 50 kN, trawersa do 1500mm typ próbki 5B,1B,1BA","methodology_en":"Tensile mechanical properties – modulus of elasticity Range: up to 50 kN, crosshead travel up to 1500mm specimen type 5B,1B,1BA","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Właściwości mechaniczne przy rozciąganiu – moduł sprężystości Zakres: do 50 kN, trawersa do 1500mm typ próbki 5B,1B,1BA","reference":"PN-EN ISO 527-1:1998 PN-EN ISO 527-2:1998 PN-EN ISO 527-3:1998","norm_bases":["PN-EN ISO 527-1:1998 PN-EN ISO 527-2:1998 PN-EN ISO 527-3:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych Właściwości mechaniczne przy rozciąganiu – moduł sprężystości Zakres: do 50 kN, trawersa do 1500mm typ próbki 5B,1B,1BA PN-EN ISO 527-1:1998 PN-EN ISO 527-2:1998 PN-EN ISO 527-3:1998 Wyroby z tworzyw sztucznych Wlasciwosci mechaniczne przy rozciaganiu – modul sprezystosci Zakres: do 50 kN, trawersa do 1500mm typ probki 5B,1B,1BA PN-EN ISO 527-1:1998 PN-EN ISO 527-2:1998 PN-EN ISO 527-3:1998","categories":["other"],"row_index":849,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products Tensile mechanical properties – modulus of elasticity Range: up to 50 kN, crosshead travel up to 1500mm specimen type 5B,1B,1BA PN-EN ISO 527-1:1998 PN-EN ISO 527-2:1998 PN-EN ISO 527-3:1998","search_zh":"塑料制品 PN-EN ISO 527-1:1998 PN-EN ISO 527-2:1998 PN-EN ISO 527-3:1998","test_object_zh":"塑料制品"},{"_id":"6a5a55f19af9f73f38251266","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby ogniochronne reaktywne","test_object_en":"Reactive fire protection products","methodology":"Grubość Zakres: (1 - 150) mm","methodology_en":"Thickness Range: (1 - 150) mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Grubość Zakres: (1 - 150) mm","reference":"EOTA TR 24:2006 am. 2009","norm_bases":["EOTA TR 24:2006 am. 2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby ogniochronne reaktywne Grubość Zakres: (1 - 150) mm EOTA TR 24:2006 am. 2009 Wyroby ogniochronne reaktywne Grubosc Zakres: (1 - 150) mm EOTA TR 24:2006 am. 2009","categories":["other"],"row_index":850,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Reactive fire protection products Thickness Range: (1 - 150) mm EOTA TR 24:2006 am. 2009","search_zh":"膨胀型防火制品 EOTA TR 24:2006 am. 2009","test_object_zh":"膨胀型防火制品"},{"_id":"6a5a55f19af9f73f38251267","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby ogniochronne reaktywne","test_object_en":"Reactive fire protection products","methodology":"Kompatybilność z metalami i tworzywami sztucznymi","methodology_en":"Compatibility with metals and plastics","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Kompatybilność z metalami i tworzywami sztucznymi","reference":"EOTA TR 24:2006 am. 2009","norm_bases":["EOTA TR 24:2006 am. 2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby ogniochronne reaktywne Kompatybilność z metalami i tworzywami sztucznymi EOTA TR 24:2006 am. 2009 Wyroby ogniochronne reaktywne Kompatybilnosc z metalami i tworzywami sztucznymi EOTA TR 24:2006 am. 2009","categories":["materials"],"row_index":851,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Reactive fire protection products Compatibility with metals and plastics EOTA TR 24:2006 am. 2009","search_zh":"膨胀型防火制品 EOTA TR 24:2006 am. 2009","test_object_zh":"膨胀型防火制品"},{"_id":"6a5a55f19af9f73f38251268","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby ogniochronne reaktywne","test_object_en":"Reactive fire protection products","methodology":"Masa powierzchniowa Zakres: (0,001 - 10) kg Metoda wagowa","methodology_en":"Mass per unit area Range: (0,001 - 10) kg Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Masa powierzchniowa Zakres: (0,001 - 10) kg Metoda wagowa","reference":"EOTA TR 024:2006 am. 2009","norm_bases":["EOTA TR 024:2006 am. 2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby ogniochronne reaktywne Masa powierzchniowa Zakres: (0,001 - 10) kg Metoda wagowa EOTA TR 024:2006 am. 2009 Wyroby ogniochronne reaktywne Masa powierzchniowa Zakres: (0,001 - 10) kg Metoda wagowa EOTA TR 024:2006 am. 2009","categories":["other"],"row_index":852,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Reactive fire protection products Mass per unit area Range: (0,001 - 10) kg Gravimetric method EOTA TR 024:2006 am. 2009","search_zh":"膨胀型防火制品 EOTA TR 024:2006 am. 2009","test_object_zh":"膨胀型防火制品"},{"_id":"6a5a55f19af9f73f38251269","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby ogniochronne reaktywne","test_object_en":"Reactive fire protection products","methodology":"Odporność oddziaływanie cyklicznie zmiennych warunków środowiskowych Zakres: temperatura do 80ºC wilgotność wzgl. do 90% typ wyrobu Z1, Z2, Y2 i Y1","methodology_en":"Resistance to the action of cyclically changing environmental conditions Range: temperature up to 80ºC rel. humidity up to 90% product type Z1, Z2, Y2 and Y1","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność oddziaływanie cyklicznie zmiennych warunków środowiskowych Zakres: temperatura do 80ºC wilgotność wzgl. do 90% typ wyrobu Z1, Z2, Y2 i Y1","reference":"EOTA TR 024:2006 am. 2009","norm_bases":["EOTA TR 024:2006 am. 2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby ogniochronne reaktywne Odporność oddziaływanie cyklicznie zmiennych warunków środowiskowych Zakres: temperatura do 80ºC wilgotność wzgl. do 90% typ wyrobu Z1, Z2, Y2 i Y1 EOTA TR 024:2006 am. 2009 Wyroby ogniochronne reaktywne Odpornosc oddzialywanie cyklicznie zmiennych warunkow srodowiskowych Zakres: temperatura do 80ºC wilgotnosc wzgl. do 90% typ wyrobu Z1, Z2, Y2 i Y1 EOTA TR 024:2006 am. 2009","categories":["environment"],"row_index":853,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Reactive fire protection products Resistance to the action of cyclically changing environmental conditions Range: temperature up to 80ºC rel. humidity up to 90% product type Z1, Z2, Y2 and Y1 EOTA TR 024:2006 am. 2009","search_zh":"膨胀型防火制品 EOTA TR 024:2006 am. 2009","test_object_zh":"膨胀型防火制品"},{"_id":"6a5a55f19af9f73f3825126a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby powłokowe do ochrony elementów metalowych","test_object_en":"Coating products for the protection of metal components","methodology":"Odporność na działanie wilgotnej atmosfery zawierającej SO 2","methodology_en":"Resistance to humid atmospheres containing SO 2","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie wilgotnej atmosfery zawierającej SO 2","reference":"PN-EN ISO 3231:2000 PN-EN ISO 6988:2000","norm_bases":["PN-EN ISO 3231:2000 PN-EN ISO 6988:2000"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby powłokowe do ochrony elementów metalowych Odporność na działanie wilgotnej atmosfery zawierającej SO 2 PN-EN ISO 3231:2000 PN-EN ISO 6988:2000 Wyroby powlokowe do ochrony elementow metalowych Odpornosc na dzialanie wilgotnej atmosfery zawierajacej SO 2 PN-EN ISO 3231:2000 PN-EN ISO 6988:2000","categories":["materials"],"row_index":854,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coating products for the protection of metal components Resistance to humid atmospheres containing SO 2 PN-EN ISO 3231:2000 PN-EN ISO 6988:2000","methodology_zh":"含 SO2 潮湿气氛的耐受性","search_zh":"含 SO2 潮湿气氛的耐受性 PN-EN ISO 3231:2000 PN-EN ISO 6988:2000"},{"_id":"6a5a55f19af9f73f3825126b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby hydroizolacyjne w postaci płynnej lub powłoki","test_object_en":"Waterproofing products in liquid or coating form","methodology":"Czas tworzenia powłoki","methodology_en":"Skin formation time","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Czas tworzenia powłoki","reference":"PN-B-24002:1997 PN-B-24000:1997","norm_bases":["PN-B-24002:1997 PN-B-24000:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby hydroizolacyjne w postaci płynnej lub powłoki Czas tworzenia powłoki PN-B-24002:1997 PN-B-24000:1997 Wyroby hydroizolacyjne w postaci plynnej lub powloki Czas tworzenia powloki PN-B-24002:1997 PN-B-24000:1997","categories":["other"],"row_index":855,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waterproofing products in liquid or coating form Skin formation time PN-B-24002:1997 PN-B-24000:1997","search_zh":"液态或涂膜型防水制品 PN-B-24002:1997 PN-B-24000:1997","test_object_zh":"液态或涂膜型防水制品"},{"_id":"6a5a55f19af9f73f3825126c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby hydroizolacyjne w postaci płynnej lub powłoki","test_object_en":"Waterproofing products in liquid or coating form","methodology":"Konsystencja robocza – ocena wizualna","methodology_en":"Working consistency – visual assessment","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Konsystencja robocza – ocena wizualna","reference":"PN-B-24000:1997","norm_bases":["PN-B-24000:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby hydroizolacyjne w postaci płynnej lub powłoki Konsystencja robocza – ocena wizualna PN-B-24000:1997 Wyroby hydroizolacyjne w postaci plynnej lub powloki Konsystencja robocza – ocena wizualna PN-B-24000:1997","categories":["other"],"row_index":856,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waterproofing products in liquid or coating form Working consistency – visual assessment PN-B-24000:1997","search_zh":"液态或涂膜型防水制品 PN-B-24000:1997","test_object_zh":"液态或涂膜型防水制品"},{"_id":"6a5a55f19af9f73f3825126d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby hydroizolacyjne w postaci płynnej lub powłoki","test_object_en":"Waterproofing products in liquid or coating form","methodology":"Wygląd zewnętrzny masy - ocena wizualna","methodology_en":"External appearance of the compound - visual assessment","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wygląd zewnętrzny masy - ocena wizualna","reference":"PN-B-24000:1997 PN-B-24002:1997","norm_bases":["PN-B-24000:1997 PN-B-24002:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby hydroizolacyjne w postaci płynnej lub powłoki Wygląd zewnętrzny masy - ocena wizualna PN-B-24000:1997 PN-B-24002:1997 Wyroby hydroizolacyjne w postaci plynnej lub powloki Wyglad zewnetrzny masy - ocena wizualna PN-B-24000:1997 PN-B-24002:1997","categories":["other"],"row_index":857,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waterproofing products in liquid or coating form External appearance of the compound - visual assessment PN-B-24000:1997 PN-B-24002:1997","search_zh":"液态或涂膜型防水制品 PN-B-24000:1997 PN-B-24002:1997","test_object_zh":"液态或涂膜型防水制品"},{"_id":"6a5a55f19af9f73f3825126e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby hydroizolacyjne w postaci płynnej lub powłoki","test_object_en":"Waterproofing products in liquid or coating form","methodology":"Zawartość niezemulgowanego asfaltu Metoda wagowa","methodology_en":"Non-emulsified bitumen content Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość niezemulgowanego asfaltu Metoda wagowa","reference":"PN-B-24002:1997","norm_bases":["PN-B-24002:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby hydroizolacyjne w postaci płynnej lub powłoki Zawartość niezemulgowanego asfaltu Metoda wagowa PN-B-24002:1997 Wyroby hydroizolacyjne w postaci plynnej lub powloki Zawartosc niezemulgowanego asfaltu Metoda wagowa PN-B-24002:1997","categories":["other"],"row_index":858,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waterproofing products in liquid or coating form Non-emulsified bitumen content Gravimetric method PN-B-24002:1997","search_zh":"液态或涂膜型防水制品 PN-B-24002:1997","test_object_zh":"液态或涂膜型防水制品"},{"_id":"6a5a55f19af9f73f3825126f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby hydroizolacyjne w postaci płynnej lub powłoki","test_object_en":"Waterproofing products in liquid or coating form","methodology":"Zdolność rozcieńczania wodą","methodology_en":"Ability to dilute with water","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność rozcieńczania wodą","reference":"PN-B-24000:1997 PN-B-24002:1997","norm_bases":["PN-B-24000:1997 PN-B-24002:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby hydroizolacyjne w postaci płynnej lub powłoki Zdolność rozcieńczania wodą PN-B-24000:1997 PN-B-24002:1997 Wyroby hydroizolacyjne w postaci plynnej lub powloki Zdolnosc rozcienczania woda PN-B-24000:1997 PN-B-24002:1997","categories":["other"],"row_index":859,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waterproofing products in liquid or coating form Ability to dilute with water PN-B-24000:1997 PN-B-24002:1997","search_zh":"液态或涂膜型防水制品 PN-B-24000:1997 PN-B-24002:1997","test_object_zh":"液态或涂膜型防水制品"},{"_id":"6a5a55f19af9f73f38251270","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby hydroizolacyjne w postaci płynnej lub powłoki","test_object_en":"Waterproofing products in liquid or coating form","methodology":"Giętkość Zakres: do -30° C Metoda przeginania na klocku","methodology_en":"Flexibility Range: down to -30° C Bending over a block method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Giętkość Zakres: do -30° C Metoda przeginania na klocku","reference":"PN-B-24000:1997","norm_bases":["PN-B-24000:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby hydroizolacyjne w postaci płynnej lub powłoki Giętkość Zakres: do -30° C Metoda przeginania na klocku PN-B-24000:1997 Wyroby hydroizolacyjne w postaci plynnej lub powloki Gietkosc Zakres: do -30° C Metoda przeginania na klocku PN-B-24000:1997","categories":["other"],"row_index":860,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waterproofing products in liquid or coating form Flexibility Range: down to -30° C Bending over a block method PN-B-24000:1997","search_zh":"液态或涂膜型防水制品 PN-B-24000:1997","test_object_zh":"液态或涂膜型防水制品"},{"_id":"6a5a55f19af9f73f38251271","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby hydroizolacyjne w postaci płynnej lub powłoki","test_object_en":"Waterproofing products in liquid or coating form","methodology":"Spływność","methodology_en":"Slip","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Spływność","reference":"PN-B-24000:1997","norm_bases":["PN-B-24000:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby hydroizolacyjne w postaci płynnej lub powłoki Spływność PN-B-24000:1997 Wyroby hydroizolacyjne w postaci plynnej lub powloki Splywnosc PN-B-24000:1997","categories":["other"],"row_index":861,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waterproofing products in liquid or coating form Slip PN-B-24000:1997","search_zh":"液态或涂膜型防水制品 流挂性 PN-B-24000:1997","test_object_zh":"液态或涂膜型防水制品","methodology_zh":"流挂性"},{"_id":"6a5a55f19af9f73f38251272","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby hydroizolacyjne w postaci płynnej lub powłoki","test_object_en":"Waterproofing products in liquid or coating form","methodology":"Przesiąkliwość powłoki Zakres: do 2m Metoda słupa wody","methodology_en":"Water penetration of the coating Range: up to 2m Water column method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przesiąkliwość powłoki Zakres: do 2m Metoda słupa wody","reference":"PN-B-24000:1997 PN-B-24002:1997","norm_bases":["PN-B-24000:1997 PN-B-24002:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby hydroizolacyjne w postaci płynnej lub powłoki Przesiąkliwość powłoki Zakres: do 2m Metoda słupa wody PN-B-24000:1997 PN-B-24002:1997 Wyroby hydroizolacyjne w postaci plynnej lub powloki Przesiakliwosc powloki Zakres: do 2m Metoda slupa wody PN-B-24000:1997 PN-B-24002:1997","categories":["water"],"row_index":862,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waterproofing products in liquid or coating form Water penetration of the coating Range: up to 2m Water column method PN-B-24000:1997 PN-B-24002:1997","search_zh":"液态或涂膜型防水制品 PN-B-24000:1997 PN-B-24002:1997","test_object_zh":"液态或涂膜型防水制品"},{"_id":"6a5a55f19af9f73f38251273","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby hydroizolacyjne w postaci płynnej lub powłoki","test_object_en":"Waterproofing products in liquid or coating form","methodology":"Spływność","methodology_en":"Slip","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Spływność","reference":"PN-B-24002:1997","norm_bases":["PN-B-24002:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby hydroizolacyjne w postaci płynnej lub powłoki Spływność PN-B-24002:1997 Wyroby hydroizolacyjne w postaci plynnej lub powloki Splywnosc PN-B-24002:1997","categories":["other"],"row_index":863,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waterproofing products in liquid or coating form Slip PN-B-24002:1997","search_zh":"液态或涂膜型防水制品 流挂性 PN-B-24002:1997","test_object_zh":"液态或涂膜型防水制品","methodology_zh":"流挂性"},{"_id":"6a5a55f19af9f73f38251274","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby hydroizolacyjne w postaci płynnej lub powłoki","test_object_en":"Waterproofing products in liquid or coating form","methodology":"Wygląd zewnętrzny powłoki -ocena wizualna","methodology_en":"External appearance of the coating -visual assessment","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wygląd zewnętrzny powłoki -ocena wizualna","reference":"PN-B-24000:1997","norm_bases":["PN-B-24000:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby hydroizolacyjne w postaci płynnej lub powłoki Wygląd zewnętrzny powłoki -ocena wizualna PN-B-24000:1997 Wyroby hydroizolacyjne w postaci plynnej lub powloki Wyglad zewnetrzny powloki -ocena wizualna PN-B-24000:1997","categories":["other"],"row_index":864,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waterproofing products in liquid or coating form External appearance of the coating -visual assessment PN-B-24000:1997","search_zh":"液态或涂膜型防水制品 PN-B-24000:1997","test_object_zh":"液态或涂膜型防水制品"},{"_id":"6a5a55f19af9f73f38251275","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby powłokowe do ochrony elementów metalowych E","test_object_en":"Coating products for the protection of metal elements E","methodology":"Grubość Metoda prądów wirowych Zakres: (4 - 30) m także in situ","methodology_en":"Thickness Eddy-current method Range: (4 - 30) m also in situ","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Grubość Metoda prądów wirowych Zakres: (4 - 30) m także in situ","reference":"PN-EN ISO 2360 „N” PN-EN ISO 2808 „N”","norm_bases":["PN-EN ISO 2360 „N” PN-EN ISO 2808 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby powłokowe do ochrony elementów metalowych E Grubość Metoda prądów wirowych Zakres: (4 - 30) m także in situ PN-EN ISO 2360 „N” PN-EN ISO 2808 „N” Wyroby powlokowe do ochrony elementow metalowych E Grubosc Metoda pradow wirowych Zakres: (4 - 30) m takze in situ PN-EN ISO 2360 „N” PN-EN ISO 2808 „N”","categories":["materials"],"row_index":865,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coating products for the protection of metal elements E Thickness Eddy-current method Range: (4 - 30) m also in situ PN-EN ISO 2360 „N” PN-EN ISO 2808 „N”","search_zh":"金属件防护涂层制品 E PN-EN ISO 2360 „N” PN-EN ISO 2808 „N”","test_object_zh":"金属件防护涂层制品 E"},{"_id":"6a5a55f19af9f73f38251276","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby powłokowe do ochrony elementów metalowych E","test_object_en":"Coating products for the protection of metal elements E","methodology":"Odporność na działanie kwaśnej mgły solnej Test AASS","methodology_en":"Resistance to acetic acid salt spray AASS test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie kwaśnej mgły solnej Test AASS","reference":"PN-EN ISO 9227","norm_bases":["PN-EN ISO 9227"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby powłokowe do ochrony elementów metalowych E Odporność na działanie kwaśnej mgły solnej Test AASS PN-EN ISO 9227 Wyroby powlokowe do ochrony elementow metalowych E Odpornosc na dzialanie kwasnej mgly solnej Test AASS PN-EN ISO 9227","categories":["materials"],"row_index":866,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coating products for the protection of metal elements E Resistance to acetic acid salt spray AASS test PN-EN ISO 9227","search_zh":"金属件防护涂层制品 E PN-EN ISO 9227","test_object_zh":"金属件防护涂层制品 E"},{"_id":"6a5a55f19af9f73f38251277","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby powłokowe do ochrony elementów metalowych E","test_object_en":"Coating products for the protection of metal elements E","methodology":"Uszczelnienie powłoki Metoda elektrochemiczna","methodology_en":"Sealing of the coating Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Uszczelnienie powłoki Metoda elektrochemiczna","reference":"PN-EN ISO 2931","norm_bases":["PN-EN ISO 2931"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby powłokowe do ochrony elementów metalowych E Uszczelnienie powłoki Metoda elektrochemiczna PN-EN ISO 2931 Wyroby powlokowe do ochrony elementow metalowych E Uszczelnienie powloki Metoda elektrochemiczna PN-EN ISO 2931","categories":["materials"],"row_index":867,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coating products for the protection of metal elements E Sealing of the coating Electrochemical method PN-EN ISO 2931","search_zh":"金属件防护涂层制品 E PN-EN ISO 2931","test_object_zh":"金属件防护涂层制品 E"},{"_id":"6a5a55f19af9f73f38251278","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby powłokowe do ochrony elementów metalowych E","test_object_en":"Coating products for the protection of metal elements E","methodology":"Uszczelnienie powłoki - ubytek masy Metoda wagowa, met. 2","methodology_en":"Sealing of the coating - mass loss Gravimetric method, method 2","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Uszczelnienie powłoki - ubytek masy Metoda wagowa, met. 2","reference":"PN-EN ISO 3210","norm_bases":["PN-EN ISO 3210"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby powłokowe do ochrony elementów metalowych E Uszczelnienie powłoki - ubytek masy Metoda wagowa, met. 2 PN-EN ISO 3210 Wyroby powlokowe do ochrony elementow metalowych E Uszczelnienie powloki - ubytek masy Metoda wagowa, met. 2 PN-EN ISO 3210","categories":["materials"],"row_index":868,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coating products for the protection of metal elements E Sealing of the coating - mass loss Gravimetric method, method 2 PN-EN ISO 3210","search_zh":"金属件防护涂层制品 E PN-EN ISO 3210","test_object_zh":"金属件防护涂层制品 E"},{"_id":"6a5a55f19af9f73f38251279","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby powłokowe do ochrony elementów metalowych E","test_object_en":"Coating products for the protection of metal elements E","methodology":"Ocena korozji wżerowej","methodology_en":"Assessment of pitting corrosion","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ocena korozji wżerowej","reference":"PN-EN ISO 8993 PN-EN ISO 8994","norm_bases":["PN-EN ISO 8993 PN-EN ISO 8994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby powłokowe do ochrony elementów metalowych E Ocena korozji wżerowej PN-EN ISO 8993 PN-EN ISO 8994 Wyroby powlokowe do ochrony elementow metalowych E Ocena korozji wzerowej PN-EN ISO 8993 PN-EN ISO 8994","categories":["materials"],"row_index":869,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coating products for the protection of metal elements E Assessment of pitting corrosion PN-EN ISO 8993 PN-EN ISO 8994","search_zh":"金属件防护涂层制品 E PN-EN ISO 8993 PN-EN ISO 8994","test_object_zh":"金属件防护涂层制品 E"},{"_id":"6a5a55f19af9f73f3825127a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Odporność na działanie wilgotnej atmosfery zawierającej SO 2","methodology_en":"Resistance to humid atmospheres containing SO 2","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie wilgotnej atmosfery zawierającej SO 2","reference":"PN-EN ISO 22479","norm_bases":["PN-EN ISO 22479"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Odporność na działanie wilgotnej atmosfery zawierającej SO 2 PN-EN ISO 22479 Wyroby z tworzyw sztucznych E Odpornosc na dzialanie wilgotnej atmosfery zawierajacej SO 2 PN-EN ISO 22479","categories":["other"],"row_index":870,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Resistance to humid atmospheres containing SO 2 PN-EN ISO 22479","search_zh":"塑料制品 E 含 SO2 潮湿气氛的耐受性 PN-EN ISO 22479","test_object_zh":"塑料制品 E","methodology_zh":"含 SO2 潮湿气氛的耐受性"},{"_id":"6a5a55f19af9f73f3825127b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Domieszki do zapraw i betonów, zaprawy E","test_object_en":"Admixtures for mortar and concrete, mortars E","methodology":"Podatność korozyjna stali zbrojeniowej w betonie Metoda elektrochemiczna","methodology_en":"Corrosion susceptibility of reinforcing steel in concrete Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Podatność korozyjna stali zbrojeniowej w betonie Metoda elektrochemiczna","reference":"PN-EN 480-14","norm_bases":["PN-EN 480-14"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Domieszki do zapraw i betonów, zaprawy E Podatność korozyjna stali zbrojeniowej w betonie Metoda elektrochemiczna PN-EN 480-14 Domieszki do zapraw i betonow, zaprawy E Podatnosc korozyjna stali zbrojeniowej w betonie Metoda elektrochemiczna PN-EN 480-14","categories":["materials","construction"],"row_index":871,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Admixtures for mortar and concrete, mortars E Corrosion susceptibility of reinforcing steel in concrete Electrochemical method PN-EN 480-14"},{"_id":"6a5a55f19af9f73f3825127c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby hydroizolacyjne rolowe E","test_object_en":"Waterproofing sheet products E","methodology":"Odporność na działanie ciekłych substancji chemicznych, w tym wody Metoda wagowa","methodology_en":"Resistance to liquid chemicals, including water Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie ciekłych substancji chemicznych, w tym wody Metoda wagowa","reference":"PN-EN ISO 175","norm_bases":["PN-EN ISO 175"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby hydroizolacyjne rolowe E Odporność na działanie ciekłych substancji chemicznych, w tym wody Metoda wagowa PN-EN ISO 175 Wyroby hydroizolacyjne rolowe E Odpornosc na dzialanie cieklych substancji chemicznych, w tym wody Metoda wagowa PN-EN ISO 175","categories":["water"],"row_index":872,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waterproofing sheet products E Resistance to liquid chemicals, including water Gravimetric method PN-EN ISO 175","search_zh":"卷材类防水制品 E 耐液体化学物质（含水）作用性 重量法 PN-EN ISO 175","test_object_zh":"卷材类防水制品 E","methodology_zh":"耐液体化学物质（含水）作用性 重量法"},{"_id":"6a5a55f19af9f73f3825127d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby hydroizolacyjne rolowe E","test_object_en":"Waterproofing sheet products E","methodology":"Przepuszczalność pary wodnej Metoda wagowa","methodology_en":"Water vapour permeability Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność pary wodnej Metoda wagowa","reference":"PN-EN 1931 „N” PN-EN ISO 12572","norm_bases":["PN-EN 1931 „N” PN-EN ISO 12572"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby hydroizolacyjne rolowe E Przepuszczalność pary wodnej Metoda wagowa PN-EN 1931 „N” PN-EN ISO 12572 Wyroby hydroizolacyjne rolowe E Przepuszczalnosc pary wodnej Metoda wagowa PN-EN 1931 „N” PN-EN ISO 12572","categories":["other"],"row_index":873,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waterproofing sheet products E Water vapour permeability Gravimetric method PN-EN 1931 „N” PN-EN ISO 12572","search_zh":"卷材类防水制品 E 水蒸气透过性 重量法 PN-EN 1931 „N” PN-EN ISO 12572","test_object_zh":"卷材类防水制品 E","methodology_zh":"水蒸气透过性 重量法"},{"_id":"6a5a55f19af9f73f3825127e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Impregnacja betonu E","test_object_en":"Concrete impregnation E","methodology":"Głębokość impregnacji Metoda wskaźnikowa","methodology_en":"Depth of impregnation Indicator method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Głębokość impregnacji Metoda wskaźnikowa","reference":"PN-EN 1504-2","norm_bases":["PN-EN 1504-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Impregnacja betonu E Głębokość impregnacji Metoda wskaźnikowa PN-EN 1504-2 Impregnacja betonu E Glebokosc impregnacji Metoda wskaznikowa PN-EN 1504-2","categories":["construction"],"row_index":874,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete impregnation E Depth of impregnation Indicator method PN-EN 1504-2"},{"_id":"6a5a55f19af9f73f3825127f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby uszczelniające i kity E","test_object_en":"Sealing products and putties E","methodology":"Odporność na działanie ciekłych substancji chemicznych, w tym wody Metoda wagowa","methodology_en":"Resistance to liquid chemicals, including water Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie ciekłych substancji chemicznych, w tym wody Metoda wagowa","reference":"PN-EN ISO 175","norm_bases":["PN-EN ISO 175"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby uszczelniające i kity E Odporność na działanie ciekłych substancji chemicznych, w tym wody Metoda wagowa PN-EN ISO 175 Wyroby uszczelniajace i kity E Odpornosc na dzialanie cieklych substancji chemicznych, w tym wody Metoda wagowa PN-EN ISO 175","categories":["water"],"row_index":875,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sealing products and putties E Resistance to liquid chemicals, including water Gravimetric method PN-EN ISO 175","search_zh":"密封制品与嵌缝膏 E 耐液体化学物质（含水）作用性 重量法 PN-EN ISO 175","test_object_zh":"密封制品与嵌缝膏 E","methodology_zh":"耐液体化学物质（含水）作用性 重量法"},{"_id":"6a5a55f19af9f73f38251280","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby metalowe E","test_object_en":"Metal products E","methodology":"Odporność na działanie mgły solnej (Test NSS, AASS)","methodology_en":"Resistance to salt spray (NSS, AASS test)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie mgły solnej (Test NSS, AASS)","reference":"PN-EN ISO 9227","norm_bases":["PN-EN ISO 9227"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby metalowe E Odporność na działanie mgły solnej (Test NSS, AASS) PN-EN ISO 9227 Wyroby metalowe E Odpornosc na dzialanie mgly solnej (Test NSS, AASS) PN-EN ISO 9227","categories":["materials"],"row_index":876,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Metal products E Resistance to salt spray (NSS, AASS test) PN-EN ISO 9227"},{"_id":"6a5a55f19af9f73f38251281","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby hydroizolacyjne rolowe E","test_object_en":"Waterproofing sheet products E","methodology":"Przepuszczalność pary wodnej Metoda wagowa","methodology_en":"Water vapour permeability Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność pary wodnej Metoda wagowa","reference":"PN-EN 1931 „N”","norm_bases":["PN-EN 1931 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby hydroizolacyjne rolowe E Przepuszczalność pary wodnej Metoda wagowa PN-EN 1931 „N” Wyroby hydroizolacyjne rolowe E Przepuszczalnosc pary wodnej Metoda wagowa PN-EN 1931 „N”","categories":["other"],"row_index":877,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waterproofing sheet products E Water vapour permeability Gravimetric method PN-EN 1931 „N”","search_zh":"卷材类防水制品 E 水蒸气透过性 重量法 PN-EN 1931 „N”","test_object_zh":"卷材类防水制品 E","methodology_zh":"水蒸气透过性 重量法"},{"_id":"6a5a55f19af9f73f38251282","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby powłokowe do ochrony elementów metalowych E","test_object_en":"Coating products for the protection of metal elements E","methodology":"Elastyczność-próba zginania (sworzeń cylindryczny) Średnica sworznia Zakres: (2 - 32) mm","methodology_en":"Flexibility - bend test (cylindrical mandrel) Mandrel diameter Range: (2 - 32) mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Elastyczność-próba zginania (sworzeń cylindryczny) Średnica sworznia Zakres: (2 - 32) mm","reference":"PN-EN ISO 1519","norm_bases":["PN-EN ISO 1519"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby powłokowe do ochrony elementów metalowych E Elastyczność-próba zginania (sworzeń cylindryczny) Średnica sworznia Zakres: (2 - 32) mm PN-EN ISO 1519 Wyroby powlokowe do ochrony elementow metalowych E Elastycznosc-proba zginania (sworzen cylindryczny) Srednica sworznia Zakres: (2 - 32) mm PN-EN ISO 1519","categories":["materials"],"row_index":878,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coating products for the protection of metal elements E Flexibility - bend test (cylindrical mandrel) Mandrel diameter Range: (2 - 32) mm PN-EN ISO 1519","search_zh":"金属件防护涂层制品 E PN-EN ISO 1519","test_object_zh":"金属件防护涂层制品 E"},{"_id":"6a5a55f19af9f73f38251283","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby powłokowe do ochrony elementów metalowych E","test_object_en":"Coating products for the protection of metal elements E","methodology":"Elastyczność – Zginanie w T, sworzeń cylindryczny i sworzeń stożkowy, Średnica sworznia cylindrycznego Zakres: (2 - 32) mm","methodology_en":"Flexibility – T-bend test, cylindrical mandrel and conical mandrel, Cylindrical mandrel diameter Range: (2 - 32) mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Elastyczność – Zginanie w T, sworzeń cylindryczny i sworzeń stożkowy, Średnica sworznia cylindrycznego Zakres: (2 - 32) mm","reference":"PN-EN 13523-7","norm_bases":["PN-EN 13523-7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby powłokowe do ochrony elementów metalowych E Elastyczność – Zginanie w T, sworzeń cylindryczny i sworzeń stożkowy, Średnica sworznia cylindrycznego Zakres: (2 - 32) mm PN-EN 13523-7 Wyroby powlokowe do ochrony elementow metalowych E Elastycznosc – Zginanie w T, sworzen cylindryczny i sworzen stozkowy, Srednica sworznia cylindrycznego Zakres: (2 - 32) mm PN-EN 13523-7","categories":["materials"],"row_index":879,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coating products for the protection of metal elements E Flexibility – T-bend test, cylindrical mandrel and conical mandrel, Cylindrical mandrel diameter Range: (2 - 32) mm PN-EN 13523-7","search_zh":"金属件防护涂层制品 E PN-EN 13523-7","test_object_zh":"金属件防护涂层制品 E"},{"_id":"6a5a55f19af9f73f38251284","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby powłokowe do ochrony elementów metalowych E","test_object_en":"Coating products for the protection of metal elements E","methodology":"Grubość Metoda prądów wirowych Metoda indukcji magnetycznej także in situ Zakres: (4 - 2000) µm","methodology_en":"Thickness Eddy-current method Magnetic induction method also in situ Range: (4 - 2000) µm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Grubość Metoda prądów wirowych Metoda indukcji magnetycznej także in situ Zakres: (4 - 2000) µm","reference":"PN-EN ISO 2808 „N“ PN-EN ISO 2178 „N“ PN-EN ISO 2360 „N“","norm_bases":["PN-EN ISO 2808 „N“ PN-EN ISO 2178 „N“ PN-EN ISO 2360 „N“"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby powłokowe do ochrony elementów metalowych E Grubość Metoda prądów wirowych Metoda indukcji magnetycznej także in situ Zakres: (4 - 2000) µm PN-EN ISO 2808 „N“ PN-EN ISO 2178 „N“ PN-EN ISO 2360 „N“ Wyroby powlokowe do ochrony elementow metalowych E Grubosc Metoda pradow wirowych Metoda indukcji magnetycznej takze in situ Zakres: (4 - 2000) µm PN-EN ISO 2808 „N“ PN-EN ISO 2178 „N“ PN-EN ISO 2360 „N“","categories":["materials"],"row_index":880,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coating products for the protection of metal elements E Thickness Eddy-current method Magnetic induction method also in situ Range: (4 - 2000) µm PN-EN ISO 2808 „N“ PN-EN ISO 2178 „N“ PN-EN ISO 2360 „N“","search_zh":"金属件防护涂层制品 E PN-EN ISO 2808 „N“ PN-EN ISO 2178 „N“ PN-EN ISO 2360 „N“","test_object_zh":"金属件防护涂层制品 E"},{"_id":"6a5a55f19af9f73f38251285","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby powłokowe do ochrony elementów metalowych E","test_object_en":"Coating products for the protection of metal elements E","methodology":"Korozja nitkowa","methodology_en":"Filiform corrosion","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Korozja nitkowa","reference":"PN-EN ISO 4623-1 PN-EN ISO 4623-2 PN-EN ISO 4628-10","norm_bases":["PN-EN ISO 4623-1 PN-EN ISO 4623-2 PN-EN ISO 4628-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby powłokowe do ochrony elementów metalowych E Korozja nitkowa PN-EN ISO 4623-1 PN-EN ISO 4623-2 PN-EN ISO 4628-10 Wyroby powlokowe do ochrony elementow metalowych E Korozja nitkowa PN-EN ISO 4623-1 PN-EN ISO 4623-2 PN-EN ISO 4628-10","categories":["materials"],"row_index":881,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coating products for the protection of metal elements E Filiform corrosion PN-EN ISO 4623-1 PN-EN ISO 4623-2 PN-EN ISO 4628-10","search_zh":"金属件防护涂层制品 E PN-EN ISO 4623-1 PN-EN ISO 4623-2 PN-EN ISO 4628-10","test_object_zh":"金属件防护涂层制品 E"},{"_id":"6a5a55f19af9f73f38251286","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby powłokowe do ochrony elementów metalowych E","test_object_en":"Coating products for the protection of metal elements E","methodology":"Masa powłoki metalicznej Metoda wagowa","methodology_en":"Mass of the metallic coating Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Masa powłoki metalicznej Metoda wagowa","reference":"PN-EN ISO 1460 PN-EN ISO 1461 „N“ PN-EN 10244-2","norm_bases":["PN-EN ISO 1460 PN-EN ISO 1461 „N“ PN-EN 10244-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby powłokowe do ochrony elementów metalowych E Masa powłoki metalicznej Metoda wagowa PN-EN ISO 1460 PN-EN ISO 1461 „N“ PN-EN 10244-2 Wyroby powlokowe do ochrony elementow metalowych E Masa powloki metalicznej Metoda wagowa PN-EN ISO 1460 PN-EN ISO 1461 „N“ PN-EN 10244-2","categories":["materials"],"row_index":882,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coating products for the protection of metal elements E Mass of the metallic coating Gravimetric method PN-EN ISO 1460 PN-EN ISO 1461 „N“ PN-EN 10244-2","search_zh":"金属件防护涂层制品 E PN-EN ISO 1460 PN-EN ISO 1461 „N“ PN-EN 10244-2","test_object_zh":"金属件防护涂层制品 E"},{"_id":"6a5a55f19af9f73f38251287","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby powłokowe do ochrony elementów metalowych E","test_object_en":"Coating products for the protection of metal elements E","methodology":"Odporność na działanie cieczy","methodology_en":"Resistance to liquids","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie cieczy","reference":"PN-EN ISO 2812-1","norm_bases":["PN-EN ISO 2812-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby powłokowe do ochrony elementów metalowych E Odporność na działanie cieczy PN-EN ISO 2812-1 Wyroby powlokowe do ochrony elementow metalowych E Odpornosc na dzialanie cieczy PN-EN ISO 2812-1","categories":["materials"],"row_index":883,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coating products for the protection of metal elements E Resistance to liquids PN-EN ISO 2812-1","search_zh":"金属件防护涂层制品 E PN-EN ISO 2812-1","test_object_zh":"金属件防护涂层制品 E"},{"_id":"6a5a55f19af9f73f38251288","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby powłokowe do ochrony elementów metalowych E","test_object_en":"Coating products for the protection of metal elements E","methodology":"Odporność na działanie mgły solnej (Test NSS) Odporność na działanie kwaśnej mgły solnej (Test AASS)","methodology_en":"Resistance to salt spray (NSS test) Resistance to acetic acid salt spray (AASS test)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie mgły solnej (Test NSS) Odporność na działanie kwaśnej mgły solnej (Test AASS)","reference":"PN-EN ISO 9227","norm_bases":["PN-EN ISO 9227"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby powłokowe do ochrony elementów metalowych E Odporność na działanie mgły solnej (Test NSS) Odporność na działanie kwaśnej mgły solnej (Test AASS) PN-EN ISO 9227 Wyroby powlokowe do ochrony elementow metalowych E Odpornosc na dzialanie mgly solnej (Test NSS) Odpornosc na dzialanie kwasnej mgly solnej (Test AASS) PN-EN ISO 9227","categories":["materials"],"row_index":884,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coating products for the protection of metal elements E Resistance to salt spray (NSS test) Resistance to acetic acid salt spray (AASS test) PN-EN ISO 9227","search_zh":"金属件防护涂层制品 E PN-EN ISO 9227","test_object_zh":"金属件防护涂层制品 E"},{"_id":"6a5a55f19af9f73f38251289","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby powłokowe do ochrony elementów metalowych E","test_object_en":"Coating products for the protection of metal elements E","methodology":"Odporność na działanie wilgoci (kondensacja ciągła)","methodology_en":"Resistance to moisture (continuous condensation)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie wilgoci (kondensacja ciągła)","reference":"PN-EN ISO 6270-1","norm_bases":["PN-EN ISO 6270-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby powłokowe do ochrony elementów metalowych E Odporność na działanie wilgoci (kondensacja ciągła) PN-EN ISO 6270-1 Wyroby powlokowe do ochrony elementow metalowych E Odpornosc na dzialanie wilgoci (kondensacja ciagla) PN-EN ISO 6270-1","categories":["materials"],"row_index":885,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coating products for the protection of metal elements E Resistance to moisture (continuous condensation) PN-EN ISO 6270-1","search_zh":"金属件防护涂层制品 E PN-EN ISO 6270-1","test_object_zh":"金属件防护涂层制品 E"},{"_id":"6a5a55f19af9f73f3825128a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby powłokowe do ochrony elementów metalowych E","test_object_en":"Coating products for the protection of metal elements E","methodology":"Odporność na działanie wilgoci i wody kondensacyjnej","methodology_en":"Resistance to moisture and condensation water","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie wilgoci i wody kondensacyjnej","reference":"PN-EN ISO 6270-2","norm_bases":["PN-EN ISO 6270-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby powłokowe do ochrony elementów metalowych E Odporność na działanie wilgoci i wody kondensacyjnej PN-EN ISO 6270-2 Wyroby powlokowe do ochrony elementow metalowych E Odpornosc na dzialanie wilgoci i wody kondensacyjnej PN-EN ISO 6270-2","categories":["materials","water"],"row_index":886,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coating products for the protection of metal elements E Resistance to moisture and condensation water PN-EN ISO 6270-2","search_zh":"金属件防护涂层制品 E PN-EN ISO 6270-2","test_object_zh":"金属件防护涂层制品 E"},{"_id":"6a5a55f19af9f73f3825128b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby powłokowe do ochrony elementów metalowych E","test_object_en":"Coating products for the protection of metal elements E","methodology":"Odporność na działanie wilgotnej atmosfery zawierającej SO 2","methodology_en":"Resistance to humid atmospheres containing SO 2","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie wilgotnej atmosfery zawierającej SO 2","reference":"PN-EN 22479","norm_bases":["PN-EN 22479"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby powłokowe do ochrony elementów metalowych E Odporność na działanie wilgotnej atmosfery zawierającej SO 2 PN-EN 22479 Wyroby powlokowe do ochrony elementow metalowych E Odpornosc na dzialanie wilgotnej atmosfery zawierajacej SO 2 PN-EN 22479","categories":["materials"],"row_index":887,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coating products for the protection of metal elements E Resistance to humid atmospheres containing SO 2 PN-EN 22479","search_zh":"金属件防护涂层制品 E 含 SO2 潮湿气氛的耐受性 PN-EN 22479","test_object_zh":"金属件防护涂层制品 E","methodology_zh":"含 SO2 潮湿气氛的耐受性"},{"_id":"6a5a55f19af9f73f3825128c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby powłokowe do ochrony elementów metalowych E","test_object_en":"Coating products for the protection of metal elements E","methodology":"Odporność na odkształcenia Metoda spadającego ciężarka. Ciężarek o masie 1 lub 2 kg, wysokość do 1 m","methodology_en":"Resistance to deformation Falling weight method. Weight of 1 or 2 kg, height up to 1 m","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na odkształcenia Metoda spadającego ciężarka. Ciężarek o masie 1 lub 2 kg, wysokość do 1 m","reference":"PN-EN ISO 6272-1","norm_bases":["PN-EN ISO 6272-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby powłokowe do ochrony elementów metalowych E Odporność na odkształcenia Metoda spadającego ciężarka. Ciężarek o masie 1 lub 2 kg, wysokość do 1 m PN-EN ISO 6272-1 Wyroby powlokowe do ochrony elementow metalowych E Odpornosc na odksztalcenia Metoda spadajacego ciezarka. Ciezarek o masie 1 lub 2 kg, wysokosc do 1 m PN-EN ISO 6272-1","categories":["materials"],"row_index":888,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coating products for the protection of metal elements E Resistance to deformation Falling weight method. Weight of 1 or 2 kg, height up to 1 m PN-EN ISO 6272-1","search_zh":"金属件防护涂层制品 E PN-EN ISO 6272-1","test_object_zh":"金属件防护涂层制品 E"},{"_id":"6a5a55f19af9f73f3825128d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby powłokowe do ochrony elementów metalowych E","test_object_en":"Coating products for the protection of metal elements E","methodology":"Odwarstwienie i skorodowanie wokół rysy Metoda wizualna","methodology_en":"Disbonding and corrosion around a scribe Visual method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odwarstwienie i skorodowanie wokół rysy Metoda wizualna","reference":"PN-EN ISO 4628-8","norm_bases":["PN-EN ISO 4628-8"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby powłokowe do ochrony elementów metalowych E Odwarstwienie i skorodowanie wokół rysy Metoda wizualna PN-EN ISO 4628-8 Wyroby powlokowe do ochrony elementow metalowych E Odwarstwienie i skorodowanie wokol rysy Metoda wizualna PN-EN ISO 4628-8","categories":["materials"],"row_index":889,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coating products for the protection of metal elements E Disbonding and corrosion around a scribe Visual method PN-EN ISO 4628-8","search_zh":"金属件防护涂层制品 E PN-EN ISO 4628-8","test_object_zh":"金属件防护涂层制品 E"},{"_id":"6a5a55f19af9f73f3825128e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby powłokowe do ochrony elementów metalowych E","test_object_en":"Coating products for the protection of metal elements E","methodology":"Przyczepność do metali i przyczepność międzywarstwowa Metoda odrywowa Zakres (0,2 - 25) kN","methodology_en":"Adhesion to metals and interlayer adhesion Pull-off method Range (0,2 - 25) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przyczepność do metali i przyczepność międzywarstwowa Metoda odrywowa Zakres (0,2 - 25) kN","reference":"PN-EN ISO 4624","norm_bases":["PN-EN ISO 4624"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby powłokowe do ochrony elementów metalowych E Przyczepność do metali i przyczepność międzywarstwowa Metoda odrywowa Zakres (0,2 - 25) kN PN-EN ISO 4624 Wyroby powlokowe do ochrony elementow metalowych E Przyczepnosc do metali i przyczepnosc miedzywarstwowa Metoda odrywowa Zakres (0,2 - 25) kN PN-EN ISO 4624","categories":["materials"],"row_index":890,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coating products for the protection of metal elements E Adhesion to metals and interlayer adhesion Pull-off method Range (0,2 - 25) kN PN-EN ISO 4624","search_zh":"金属件防护涂层制品 E PN-EN ISO 4624","test_object_zh":"金属件防护涂层制品 E"},{"_id":"6a5a55f19af9f73f3825128f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby powłokowe do ochrony elementów metalowych E","test_object_en":"Coating products for the protection of metal elements E","methodology":"Skredowanie metodą aksamitu Metoda wizualna także in situ","methodology_en":"Chalking by the velvet method Visual method also in situ","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skredowanie metodą aksamitu Metoda wizualna także in situ","reference":"PN-EN ISO 4628-7","norm_bases":["PN-EN ISO 4628-7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby powłokowe do ochrony elementów metalowych E Skredowanie metodą aksamitu Metoda wizualna także in situ PN-EN ISO 4628-7 Wyroby powlokowe do ochrony elementow metalowych E Skredowanie metoda aksamitu Metoda wizualna takze in situ PN-EN ISO 4628-7","categories":["materials"],"row_index":891,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coating products for the protection of metal elements E Chalking by the velvet method Visual method also in situ PN-EN ISO 4628-7","search_zh":"金属件防护涂层制品 E PN-EN ISO 4628-7","test_object_zh":"金属件防护涂层制品 E"},{"_id":"6a5a55f19af9f73f38251290","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby powłokowe do ochrony elementów metalowych E","test_object_en":"Coating products for the protection of metal elements E","methodology":"Tłoczność Metoda powolnego odkształcenia Zakres (0 -30) mm","methodology_en":"Cupping Slow deformation method Range (0 -30) mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Tłoczność Metoda powolnego odkształcenia Zakres (0 -30) mm","reference":"PN-EN ISO 1520","norm_bases":["PN-EN ISO 1520"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby powłokowe do ochrony elementów metalowych E Tłoczność Metoda powolnego odkształcenia Zakres (0 -30) mm PN-EN ISO 1520 Wyroby powlokowe do ochrony elementow metalowych E Tlocznosc Metoda powolnego odksztalcenia Zakres (0 -30) mm PN-EN ISO 1520","categories":["materials"],"row_index":892,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coating products for the protection of metal elements E Cupping Slow deformation method Range (0 -30) mm PN-EN ISO 1520","search_zh":"金属件防护涂层制品 E PN-EN ISO 1520","test_object_zh":"金属件防护涂层制品 E"},{"_id":"6a5a55f19af9f73f38251291","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby powłokowe do ochrony elementów metalowych E","test_object_en":"Coating products for the protection of metal elements E","methodology":"Twardość Metoda Buchholza","methodology_en":"Hardness Buchholz method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Twardość Metoda Buchholza","reference":"PN-EN ISO 2815","norm_bases":["PN-EN ISO 2815"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby powłokowe do ochrony elementów metalowych E Twardość Metoda Buchholza PN-EN ISO 2815 Wyroby powlokowe do ochrony elementow metalowych E Twardosc Metoda Buchholza PN-EN ISO 2815","categories":["materials"],"row_index":893,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coating products for the protection of metal elements E Hardness Buchholz method PN-EN ISO 2815","search_zh":"金属件防护涂层制品 E PN-EN ISO 2815","test_object_zh":"金属件防护涂层制品 E"},{"_id":"6a5a55f19af9f73f38251292","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby powłokowe do ochrony elementów metalowych E","test_object_en":"Coating products for the protection of metal elements E","methodology":"Wygląd powierzchni Metoda wizualna, w tym in situ","methodology_en":"Surface appearance Visual method, including in situ","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wygląd powierzchni Metoda wizualna, w tym in situ","reference":"PN-EN ISO 1461 „N“","norm_bases":["PN-EN ISO 1461 „N“"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby powłokowe do ochrony elementów metalowych E Wygląd powierzchni Metoda wizualna, w tym in situ PN-EN ISO 1461 „N“ Wyroby powlokowe do ochrony elementow metalowych E Wyglad powierzchni Metoda wizualna, w tym in situ PN-EN ISO 1461 „N“","categories":["materials"],"row_index":894,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coating products for the protection of metal elements E Surface appearance Visual method, including in situ PN-EN ISO 1461 „N“","search_zh":"金属件防护涂层制品 E PN-EN ISO 1461 „N“","test_object_zh":"金属件防护涂层制品 E"},{"_id":"6a5a55f19af9f73f38251293","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby powłokowe do ochrony elementów metalowych E","test_object_en":"Coating products for the protection of metal elements E","methodology":"Zardzewienie Metoda wizualna także in situ","methodology_en":"Rusting Visual method, also in situ","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zardzewienie Metoda wizualna także in situ","reference":"PN-EN ISO 4628-3","norm_bases":["PN-EN ISO 4628-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby powłokowe do ochrony elementów metalowych E Zardzewienie Metoda wizualna także in situ PN-EN ISO 4628-3 Wyroby powlokowe do ochrony elementow metalowych E Zardzewienie Metoda wizualna takze in situ PN-EN ISO 4628-3","categories":["materials"],"row_index":895,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coating products for the protection of metal elements E Rusting Visual method, also in situ PN-EN ISO 4628-3","search_zh":"金属件防护涂层制品 E PN-EN ISO 4628-3","test_object_zh":"金属件防护涂层制品 E"},{"_id":"6a5a55f19af9f73f38251294","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby powłokowe do ochrony elementów metalowych E","test_object_en":"Coating products for the protection of metal elements E","methodology":"Złuszczenie Metoda wizualna także in situ","methodology_en":"Flaking Visual method also in situ","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Złuszczenie Metoda wizualna także in situ","reference":"PN-EN ISO 4628-5","norm_bases":["PN-EN ISO 4628-5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby powłokowe do ochrony elementów metalowych E Złuszczenie Metoda wizualna także in situ PN-EN ISO 4628-5 Wyroby powlokowe do ochrony elementow metalowych E Zluszczenie Metoda wizualna takze in situ PN-EN ISO 4628-5","categories":["materials"],"row_index":896,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coating products for the protection of metal elements E Flaking Visual method also in situ PN-EN ISO 4628-5","search_zh":"金属件防护涂层制品 E PN-EN ISO 4628-5","test_object_zh":"金属件防护涂层制品 E"},{"_id":"6a5a55f19af9f73f38251295","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby powłokowe do ochrony elementów metalowych E","test_object_en":"Coating products for the protection of metal elements E","methodology":"Zniszczenie – ilość i rozmiar uszkodzeń Metoda wizualna także in situ","methodology_en":"Damage – number and size of defects Visual method also in situ","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zniszczenie – ilość i rozmiar uszkodzeń Metoda wizualna także in situ","reference":"PN-EN ISO 4628-1","norm_bases":["PN-EN ISO 4628-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby powłokowe do ochrony elementów metalowych E Zniszczenie – ilość i rozmiar uszkodzeń Metoda wizualna także in situ PN-EN ISO 4628-1 Wyroby powlokowe do ochrony elementow metalowych E Zniszczenie – ilosc i rozmiar uszkodzen Metoda wizualna takze in situ PN-EN ISO 4628-1","categories":["materials"],"row_index":897,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coating products for the protection of metal elements E Damage – number and size of defects Visual method also in situ PN-EN ISO 4628-1","search_zh":"金属件防护涂层制品 E PN-EN ISO 4628-1","test_object_zh":"金属件防护涂层制品 E"},{"_id":"6a5a55f19af9f73f38251296","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby powłokowe do ochrony elementów metalowych E","test_object_en":"Coating products for the protection of metal elements E","methodology":"Przyczepność Metoda siatki nacięć – metoda ręczna","methodology_en":"Adhesion Cross-cut method – manual method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przyczepność Metoda siatki nacięć – metoda ręczna","reference":"PN-EN ISO 2409","norm_bases":["PN-EN ISO 2409"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby powłokowe do ochrony elementów metalowych E Przyczepność Metoda siatki nacięć – metoda ręczna PN-EN ISO 2409 Wyroby powlokowe do ochrony elementow metalowych E Przyczepnosc Metoda siatki naciec – metoda reczna PN-EN ISO 2409","categories":["materials"],"row_index":898,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coating products for the protection of metal elements E Adhesion Cross-cut method – manual method PN-EN ISO 2409","search_zh":"金属件防护涂层制品 E PN-EN ISO 2409","test_object_zh":"金属件防护涂层制品 E"},{"_id":"6a5a55f19af9f73f38251297","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby powłokowe do ochrony elementów metalowych E","test_object_en":"Coating products for the protection of metal elements E","methodology":"Elastyczność-przeginanie na sworzniu Średnica sworznia Zakres: (2 - 32) mm","methodology_en":"Flexibility - bending on a mandrel Mandrel diameter Range: (2 - 32) mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Elastyczność-przeginanie na sworzniu Średnica sworznia Zakres: (2 - 32) mm","reference":"PN-EN ISO 1519","norm_bases":["PN-EN ISO 1519"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby powłokowe do ochrony elementów metalowych E Elastyczność-przeginanie na sworzniu Średnica sworznia Zakres: (2 - 32) mm PN-EN ISO 1519 Wyroby powlokowe do ochrony elementow metalowych E Elastycznosc-przeginanie na sworzniu Srednica sworznia Zakres: (2 - 32) mm PN-EN ISO 1519","categories":["materials"],"row_index":899,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coating products for the protection of metal elements E Flexibility - bending on a mandrel Mandrel diameter Range: (2 - 32) mm PN-EN ISO 1519","search_zh":"金属件防护涂层制品 E PN-EN ISO 1519","test_object_zh":"金属件防护涂层制品 E"},{"_id":"6a5a55f19af9f73f38251298","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby powłokowe do ochrony elementów metalowych E","test_object_en":"Coating products for the protection of metal elements E","methodology":"Masa Metoda wagowa","methodology_en":"Mass Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Masa Metoda wagowa","reference":"PN-EN 10346, Załącznik A","norm_bases":["PN-EN 10346, Załącznik A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby powłokowe do ochrony elementów metalowych E Masa Metoda wagowa PN-EN 10346, Załącznik A Wyroby powlokowe do ochrony elementow metalowych E Masa Metoda wagowa PN-EN 10346, Zalacznik A","categories":["materials"],"row_index":900,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coating products for the protection of metal elements E Mass Gravimetric method PN-EN 10346, Załącznik A","search_zh":"金属件防护涂层制品 E PN-EN 10346, Załącznik A","test_object_zh":"金属件防护涂层制品 E"},{"_id":"6a5a55f19af9f73f38251299","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Powłoki na betonie E","test_object_en":"Coatings on concrete E","methodology":"Kompatybilność termiczna - cykliczne zamrażanie i rozmrażanie w soli odladzającej Zakres: (0,2 - 25) kN","methodology_en":"Thermal compatibility - freeze-thaw cycling with de-icing salt Range: (0,2 - 25) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Kompatybilność termiczna - cykliczne zamrażanie i rozmrażanie w soli odladzającej Zakres: (0,2 - 25) kN","reference":"PN-EN 13687-1","norm_bases":["PN-EN 13687-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki na betonie E Kompatybilność termiczna - cykliczne zamrażanie i rozmrażanie w soli odladzającej Zakres: (0,2 - 25) kN PN-EN 13687-1 Powloki na betonie E Kompatybilnosc termiczna - cykliczne zamrazanie i rozmrazanie w soli odladzajacej Zakres: (0,2 - 25) kN PN-EN 13687-1","categories":["construction"],"row_index":901,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coatings on concrete E Thermal compatibility - freeze-thaw cycling with de-icing salt Range: (0,2 - 25) kN PN-EN 13687-1","search_zh":"混凝土表面涂层 E PN-EN 13687-1","test_object_zh":"混凝土表面涂层 E"},{"_id":"6a5a55f19af9f73f3825129a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Powłoki na betonie E","test_object_en":"Coatings on concrete E","methodology":"Odporność na warunki klimatyczne","methodology_en":"Resistance to climatic conditions","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na warunki klimatyczne","reference":"PN-EN 1062-11","norm_bases":["PN-EN 1062-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki na betonie E Odporność na warunki klimatyczne PN-EN 1062-11 Powloki na betonie E Odpornosc na warunki klimatyczne PN-EN 1062-11","categories":["construction"],"row_index":902,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coatings on concrete E Resistance to climatic conditions PN-EN 1062-11","search_zh":"混凝土表面涂层 E PN-EN 1062-11","test_object_zh":"混凝土表面涂层 E"},{"_id":"6a5a55f19af9f73f3825129b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Powłoki na betonie E","test_object_en":"Coatings on concrete E","methodology":"Odporność chemiczna - zmiana wyglądu i przyczepności Zakres: (0,2 - 25) kN lub twardości Zakres: skala A i D Metoda bez ciśnienia","methodology_en":"Chemical resistance - change in appearance and adhesion Range: (0,2 - 25) kN or hardness Range: scale A and D Method without pressure","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność chemiczna - zmiana wyglądu i przyczepności Zakres: (0,2 - 25) kN lub twardości Zakres: skala A i D Metoda bez ciśnienia","reference":"PN-EN 13529","norm_bases":["PN-EN 13529"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki na betonie E Odporność chemiczna - zmiana wyglądu i przyczepności Zakres: (0,2 - 25) kN lub twardości Zakres: skala A i D Metoda bez ciśnienia PN-EN 13529 Powloki na betonie E Odpornosc chemiczna - zmiana wygladu i przyczepnosci Zakres: (0,2 - 25) kN lub twardosci Zakres: skala A i D Metoda bez cisnienia PN-EN 13529","categories":["construction"],"row_index":903,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coatings on concrete E Chemical resistance - change in appearance and adhesion Range: (0,2 - 25) kN or hardness Range: scale A and D Method without pressure PN-EN 13529","search_zh":"混凝土表面涂层 E PN-EN 13529","test_object_zh":"混凝土表面涂层 E"},{"_id":"6a5a55f19af9f73f3825129c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Powłoki na betonie E","test_object_en":"Coatings on concrete E","methodology":"Odporność na ścieranie (test Tabera) Metoda wagowa","methodology_en":"Abrasion resistance (Taber test) Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na ścieranie (test Tabera) Metoda wagowa","reference":"PN-EN ISO 5470-1","norm_bases":["PN-EN ISO 5470-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki na betonie E Odporność na ścieranie (test Tabera) Metoda wagowa PN-EN ISO 5470-1 Powloki na betonie E Odpornosc na scieranie (test Tabera) Metoda wagowa PN-EN ISO 5470-1","categories":["construction"],"row_index":904,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coatings on concrete E Abrasion resistance (Taber test) Gravimetric method PN-EN ISO 5470-1","search_zh":"混凝土表面涂层 E PN-EN ISO 5470-1","test_object_zh":"混凝土表面涂层 E"},{"_id":"6a5a55f19af9f73f3825129d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Powłoki na betonie E","test_object_en":"Coatings on concrete E","methodology":"Pokrywanie rys Metoda rozciągania na betonie, met.A","methodology_en":"Crack bridging Tensile method on concrete, method A","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pokrywanie rys Metoda rozciągania na betonie, met.A","reference":"PN-EN 1062-7","norm_bases":["PN-EN 1062-7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki na betonie E Pokrywanie rys Metoda rozciągania na betonie, met.A PN-EN 1062-7 Powloki na betonie E Pokrywanie rys Metoda rozciagania na betonie, met.A PN-EN 1062-7","categories":["construction"],"row_index":905,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coatings on concrete E Crack bridging Tensile method on concrete, method A PN-EN 1062-7","search_zh":"混凝土表面涂层 E PN-EN 1062-7","test_object_zh":"混凝土表面涂层 E"},{"_id":"6a5a55f19af9f73f3825129e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Powłoki na betonie E","test_object_en":"Coatings on concrete E","methodology":"Przepuszczalność dwutlenku węgla Metoda wagowa","methodology_en":"Carbon dioxide permeability Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność dwutlenku węgla Metoda wagowa","reference":"PN-EN 1062-6","norm_bases":["PN-EN 1062-6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki na betonie E Przepuszczalność dwutlenku węgla Metoda wagowa PN-EN 1062-6 Powloki na betonie E Przepuszczalnosc dwutlenku wegla Metoda wagowa PN-EN 1062-6","categories":["construction"],"row_index":906,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coatings on concrete E Carbon dioxide permeability Gravimetric method PN-EN 1062-6","search_zh":"混凝土表面涂层 E PN-EN 1062-6","test_object_zh":"混凝土表面涂层 E"},{"_id":"6a5a55f19af9f73f3825129f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Powłoki na betonie E","test_object_en":"Coatings on concrete E","methodology":"Przepuszczalność pary wodnej Metoda wagowa","methodology_en":"Water vapour permeability Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność pary wodnej Metoda wagowa","reference":"PN-EN ISO 7783","norm_bases":["PN-EN ISO 7783"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki na betonie E Przepuszczalność pary wodnej Metoda wagowa PN-EN ISO 7783 Powloki na betonie E Przepuszczalnosc pary wodnej Metoda wagowa PN-EN ISO 7783","categories":["construction"],"row_index":907,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coatings on concrete E Water vapour permeability Gravimetric method PN-EN ISO 7783","search_zh":"混凝土表面涂层 E 水蒸气透过性 重量法 PN-EN ISO 7783","test_object_zh":"混凝土表面涂层 E","methodology_zh":"水蒸气透过性 重量法"},{"_id":"6a5a55f19af9f73f382512a0","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Powłoki na betonie E","test_object_en":"Coatings on concrete E","methodology":"Przepuszczalność wody Metoda wagowa","methodology_en":"Water permeability Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność wody Metoda wagowa","reference":"PN-EN 1062-3","norm_bases":["PN-EN 1062-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki na betonie E Przepuszczalność wody Metoda wagowa PN-EN 1062-3 Powloki na betonie E Przepuszczalnosc wody Metoda wagowa PN-EN 1062-3","categories":["water","construction"],"row_index":908,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coatings on concrete E Water permeability Gravimetric method PN-EN 1062-3","search_zh":"混凝土表面涂层 E PN-EN 1062-3","test_object_zh":"混凝土表面涂层 E"},{"_id":"6a5a55f19af9f73f382512a1","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Powłoki na betonie E","test_object_en":"Coatings on concrete E","methodology":"Przyczepność do betonu Metoda odrywowa Zakres: (0,2 - 25) kN Krążki o średnicy 5 cm także in situ","methodology_en":"Adhesion to concrete Pull-off method Range: (0,2 - 25) kN Discs of 5 cm diameter also in situ","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przyczepność do betonu Metoda odrywowa Zakres: (0,2 - 25) kN Krążki o średnicy 5 cm także in situ","reference":"PN-EN 1542","norm_bases":["PN-EN 1542"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki na betonie E Przyczepność do betonu Metoda odrywowa Zakres: (0,2 - 25) kN Krążki o średnicy 5 cm także in situ PN-EN 1542 Powloki na betonie E Przyczepnosc do betonu Metoda odrywowa Zakres: (0,2 - 25) kN Krazki o srednicy 5 cm takze in situ PN-EN 1542","categories":["construction"],"row_index":909,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coatings on concrete E Adhesion to concrete Pull-off method Range: (0,2 - 25) kN Discs of 5 cm diameter also in situ PN-EN 1542","search_zh":"混凝土表面涂层 E PN-EN 1542","test_object_zh":"混凝土表面涂层 E"},{"_id":"6a5a55f19af9f73f382512a2","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Powłoki na betonie E","test_object_en":"Coatings on concrete E","methodology":"Przyczepność do betonu Metoda odrywowa Zakres: (0,2 - 25) kN krążki o średnicy 2 cm także in situ","methodology_en":"Adhesion to concrete Pull-off method Range: (0,2 - 25) kN discs of 2 cm diameter also in situ","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przyczepność do betonu Metoda odrywowa Zakres: (0,2 - 25) kN krążki o średnicy 2 cm także in situ","reference":"PN-EN ISO 4624","norm_bases":["PN-EN ISO 4624"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki na betonie E Przyczepność do betonu Metoda odrywowa Zakres: (0,2 - 25) kN krążki o średnicy 2 cm także in situ PN-EN ISO 4624 Powloki na betonie E Przyczepnosc do betonu Metoda odrywowa Zakres: (0,2 - 25) kN krazki o srednicy 2 cm takze in situ PN-EN ISO 4624","categories":["construction"],"row_index":910,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coatings on concrete E Adhesion to concrete Pull-off method Range: (0,2 - 25) kN discs of 2 cm diameter also in situ PN-EN ISO 4624","search_zh":"混凝土表面涂层 E PN-EN ISO 4624","test_object_zh":"混凝土表面涂层 E"},{"_id":"6a5a55f19af9f73f382512a3","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Powłoki na betonie E","test_object_en":"Coatings on concrete E","methodology":"Odporność na działanie cieczy Metoda wizualna","methodology_en":"Resistance to liquids Visual method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie cieczy Metoda wizualna","reference":"PN-EN ISO 2812-1","norm_bases":["PN-EN ISO 2812-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki na betonie E Odporność na działanie cieczy Metoda wizualna PN-EN ISO 2812-1 Powloki na betonie E Odpornosc na dzialanie cieczy Metoda wizualna PN-EN ISO 2812-1","categories":["construction"],"row_index":911,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coatings on concrete E Resistance to liquids Visual method PN-EN ISO 2812-1","search_zh":"混凝土表面涂层 E PN-EN ISO 2812-1","test_object_zh":"混凝土表面涂层 E"},{"_id":"6a5a55f19af9f73f382512a4","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Powłoki E","test_object_en":"Coatings E","methodology":"Ochrona zbrojenia przed korozją","methodology_en":"Protection of reinforcement against corrosion","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ochrona zbrojenia przed korozją","reference":"PN-EN 15183","norm_bases":["PN-EN 15183"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki E Ochrona zbrojenia przed korozją PN-EN 15183 Powloki E Ochrona zbrojenia przed korozja PN-EN 15183","categories":["other"],"row_index":912,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coatings E Protection of reinforcement against corrosion PN-EN 15183","search_zh":"涂层 E PN-EN 15183","test_object_zh":"涂层 E"},{"_id":"6a5a55f19af9f73f382512a5","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Tynki i zaprawy E","test_object_en":"Plasters and mortars E","methodology":"Absorpcja kapilarna Metoda wagowa","methodology_en":"Capillary absorption Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Absorpcja kapilarna Metoda wagowa","reference":"PN-EN 13057","norm_bases":["PN-EN 13057"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tynki i zaprawy E Absorpcja kapilarna Metoda wagowa PN-EN 13057 Tynki i zaprawy E Absorpcja kapilarna Metoda wagowa PN-EN 13057","categories":["other"],"row_index":913,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plasters and mortars E Capillary absorption Gravimetric method PN-EN 13057","search_zh":"抹面砂浆与砌筑砂浆 E PN-EN 13057","test_object_zh":"抹面砂浆与砌筑砂浆 E"},{"_id":"6a5a55f19af9f73f382512a6","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Tynki i zaprawy E","test_object_en":"Plasters and mortars E","methodology":"Kompatybilność termiczna - cykliczne zamrażanie i rozmrażanie w soli odladzającej Zakres: (0,2 - 25) kN","methodology_en":"Thermal compatibility - freeze-thaw cycling with de-icing salt Range: (0,2 - 25) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Kompatybilność termiczna - cykliczne zamrażanie i rozmrażanie w soli odladzającej Zakres: (0,2 - 25) kN","reference":"PN-EN 13687-1","norm_bases":["PN-EN 13687-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tynki i zaprawy E Kompatybilność termiczna - cykliczne zamrażanie i rozmrażanie w soli odladzającej Zakres: (0,2 - 25) kN PN-EN 13687-1 Tynki i zaprawy E Kompatybilnosc termiczna - cykliczne zamrazanie i rozmrazanie w soli odladzajacej Zakres: (0,2 - 25) kN PN-EN 13687-1","categories":["other"],"row_index":914,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plasters and mortars E Thermal compatibility - freeze-thaw cycling with de-icing salt Range: (0,2 - 25) kN PN-EN 13687-1","search_zh":"抹面砂浆与砌筑砂浆 E PN-EN 13687-1","test_object_zh":"抹面砂浆与砌筑砂浆 E"},{"_id":"6a5a55f19af9f73f382512a7","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Tynki i zaprawy E","test_object_en":"Plasters and mortars E","methodology":"Przepuszczalność pary wodnej","methodology_en":"Water vapour permeability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność pary wodnej","reference":"PN-EN 1015-19","norm_bases":["PN-EN 1015-19"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tynki i zaprawy E Przepuszczalność pary wodnej PN-EN 1015-19 Tynki i zaprawy E Przepuszczalnosc pary wodnej PN-EN 1015-19","categories":["other"],"row_index":915,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plasters and mortars E Water vapour permeability PN-EN 1015-19","search_zh":"抹面砂浆与砌筑砂浆 E 水蒸气透过性 PN-EN 1015-19","test_object_zh":"抹面砂浆与砌筑砂浆 E","methodology_zh":"水蒸气透过性"},{"_id":"6a5a55f19af9f73f382512a8","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Tynki i zaprawy E","test_object_en":"Plasters and mortars E","methodology":"Przyczepność metoda odrywowa Zakres: (0,2 - 25) kN (krążki o średnicy 50mm)","methodology_en":"Adhesion pull-off method Range: (0,2 - 25) kN (discs of 50mm diameter)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przyczepność metoda odrywowa Zakres: (0,2 - 25) kN (krążki o średnicy 50mm)","reference":"PN-EN 1542","norm_bases":["PN-EN 1542"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tynki i zaprawy E Przyczepność metoda odrywowa Zakres: (0,2 - 25) kN (krążki o średnicy 50mm) PN-EN 1542 Tynki i zaprawy E Przyczepnosc metoda odrywowa Zakres: (0,2 - 25) kN (krazki o srednicy 50mm) PN-EN 1542","categories":["other"],"row_index":916,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plasters and mortars E Adhesion pull-off method Range: (0,2 - 25) kN (discs of 50mm diameter) PN-EN 1542","search_zh":"抹面砂浆与砌筑砂浆 E PN-EN 1542","test_object_zh":"抹面砂浆与砌筑砂浆 E"},{"_id":"6a5a55f19af9f73f382512a9","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Tynki i zaprawy E","test_object_en":"Plasters and mortars E","methodology":"Wytrzymałość na ściskanie Zakres: (30 - 250) kN, próbka (40x40x160) mm i (40x40x40) mm","methodology_en":"Compressive strength Range: (30 - 250) kN, specimen (40x40x160) mm and (40x40x40) mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie Zakres: (30 - 250) kN, próbka (40x40x160) mm i (40x40x40) mm","reference":"PN-EN 12190","norm_bases":["PN-EN 12190"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tynki i zaprawy E Wytrzymałość na ściskanie Zakres: (30 - 250) kN, próbka (40x40x160) mm i (40x40x40) mm PN-EN 12190 Tynki i zaprawy E Wytrzymalosc na sciskanie Zakres: (30 - 250) kN, probka (40x40x160) mm i (40x40x40) mm PN-EN 12190","categories":["other"],"row_index":917,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plasters and mortars E Compressive strength Range: (30 - 250) kN, specimen (40x40x160) mm and (40x40x40) mm PN-EN 12190","search_zh":"抹面砂浆与砌筑砂浆 E PN-EN 12190","test_object_zh":"抹面砂浆与砌筑砂浆 E"},{"_id":"6a5a55f19af9f73f382512aa","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby hydroizolacyjne rolowe E","test_object_en":"Waterproofing sheet products E","methodology":"Właściwości mechaniczne przy rozciąganiu Zakres: do 10 kN, Trawersa do 1500 mm","methodology_en":"Tensile mechanical properties Range: up to 10 kN, Crosshead travel up to 1500 mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Właściwości mechaniczne przy rozciąganiu Zakres: do 10 kN, Trawersa do 1500 mm","reference":"PN-EN 12311-1 PN-EN 12311-2","norm_bases":["PN-EN 12311-1 PN-EN 12311-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby hydroizolacyjne rolowe E Właściwości mechaniczne przy rozciąganiu Zakres: do 10 kN, Trawersa do 1500 mm PN-EN 12311-1 PN-EN 12311-2 Wyroby hydroizolacyjne rolowe E Wlasciwosci mechaniczne przy rozciaganiu Zakres: do 10 kN, Trawersa do 1500 mm PN-EN 12311-1 PN-EN 12311-2","categories":["other"],"row_index":918,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waterproofing sheet products E Tensile mechanical properties Range: up to 10 kN, Crosshead travel up to 1500 mm PN-EN 12311-1 PN-EN 12311-2","search_zh":"卷材类防水制品 E PN-EN 12311-1 PN-EN 12311-2","test_object_zh":"卷材类防水制品 E"},{"_id":"6a5a55f19af9f73f382512ab","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby hydroizolacyjne rolowe E","test_object_en":"Waterproofing sheet products E","methodology":"Przesiąkanie wody","methodology_en":"Water seepage","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przesiąkanie wody","reference":"PN-EN 13111 „N”","norm_bases":["PN-EN 13111 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby hydroizolacyjne rolowe E Przesiąkanie wody PN-EN 13111 „N” Wyroby hydroizolacyjne rolowe E Przesiakanie wody PN-EN 13111 „N”","categories":["water"],"row_index":919,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waterproofing sheet products E Water seepage PN-EN 13111 „N”","search_zh":"卷材类防水制品 E PN-EN 13111 „N”","test_object_zh":"卷材类防水制品 E"},{"_id":"6a5a55f19af9f73f382512ac","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby hydroizolacyjne rolowe E","test_object_en":"Waterproofing sheet products E","methodology":"Właściwości mechaniczne przy rozciąganiu Maszyna wytrzymałościowa do 10 kN, trawersa do 1500 mm","methodology_en":"Tensile mechanical properties Testing machine up to 10 kN, crosshead travel up to 1500 mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Właściwości mechaniczne przy rozciąganiu Maszyna wytrzymałościowa do 10 kN, trawersa do 1500 mm","reference":"PN-EN 12311-1","norm_bases":["PN-EN 12311-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby hydroizolacyjne rolowe E Właściwości mechaniczne przy rozciąganiu Maszyna wytrzymałościowa do 10 kN, trawersa do 1500 mm PN-EN 12311-1 Wyroby hydroizolacyjne rolowe E Wlasciwosci mechaniczne przy rozciaganiu Maszyna wytrzymalosciowa do 10 kN, trawersa do 1500 mm PN-EN 12311-1","categories":["other"],"row_index":920,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waterproofing sheet products E Tensile mechanical properties Testing machine up to 10 kN, crosshead travel up to 1500 mm PN-EN 12311-1","search_zh":"卷材类防水制品 E PN-EN 12311-1","test_object_zh":"卷材类防水制品 E"},{"_id":"6a5a55f19af9f73f382512ad","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby hydroizolacyjne rolowe E","test_object_en":"Waterproofing sheet products E","methodology":"Przesiąkanie wody Zakres: do 1,6 MPa Metoda ciśnieniowa","methodology_en":"Water penetration Range: up to 1,6 MPa Pressure method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przesiąkanie wody Zakres: do 1,6 MPa Metoda ciśnieniowa","reference":"PN-EN 13859-1 „N” PN-EN 13859-2 „N”","norm_bases":["PN-EN 13859-1 „N” PN-EN 13859-2 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby hydroizolacyjne rolowe E Przesiąkanie wody Zakres: do 1,6 MPa Metoda ciśnieniowa PN-EN 13859-1 „N” PN-EN 13859-2 „N” Wyroby hydroizolacyjne rolowe E Przesiakanie wody Zakres: do 1,6 MPa Metoda cisnieniowa PN-EN 13859-1 „N” PN-EN 13859-2 „N”","categories":["water"],"row_index":921,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waterproofing sheet products E Water penetration Range: up to 1,6 MPa Pressure method PN-EN 13859-1 „N” PN-EN 13859-2 „N”","search_zh":"卷材类防水制品 E PN-EN 13859-1 „N” PN-EN 13859-2 „N”","test_object_zh":"卷材类防水制品 E"},{"_id":"6a5a55f19af9f73f382512ae","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby hydroizolacyjne rolowe E","test_object_en":"Waterproofing sheet products E","methodology":"Wytrzymałość złączy na oddzieranie Maszyna wytrzymałościowa do 10 kN","methodology_en":"Peel strength of the joints Testing machine up to 10 kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość złączy na oddzieranie Maszyna wytrzymałościowa do 10 kN","reference":"PN-EN 12316-1","norm_bases":["PN-EN 12316-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby hydroizolacyjne rolowe E Wytrzymałość złączy na oddzieranie Maszyna wytrzymałościowa do 10 kN PN-EN 12316-1 Wyroby hydroizolacyjne rolowe E Wytrzymalosc zlaczy na oddzieranie Maszyna wytrzymalosciowa do 10 kN PN-EN 12316-1","categories":["other"],"row_index":922,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waterproofing sheet products E Peel strength of the joints Testing machine up to 10 kN PN-EN 12316-1","search_zh":"卷材类防水制品 E PN-EN 12316-1","test_object_zh":"卷材类防水制品 E"},{"_id":"6a5a55f19af9f73f382512af","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby hydroizolacyjne rolowe E","test_object_en":"Waterproofing sheet products E","methodology":"Wytrzymałość złączy na ścinanie Maszyna wytrzymałościowa do 10 kN","methodology_en":"Shear strength of the joints Testing machine up to 10 kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość złączy na ścinanie Maszyna wytrzymałościowa do 10 kN","reference":"PN-EN 12317-1","norm_bases":["PN-EN 12317-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby hydroizolacyjne rolowe E Wytrzymałość złączy na ścinanie Maszyna wytrzymałościowa do 10 kN PN-EN 12317-1 Wyroby hydroizolacyjne rolowe E Wytrzymalosc zlaczy na scinanie Maszyna wytrzymalosciowa do 10 kN PN-EN 12317-1","categories":["other"],"row_index":923,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waterproofing sheet products E Shear strength of the joints Testing machine up to 10 kN PN-EN 12317-1","search_zh":"卷材类防水制品 E PN-EN 12317-1","test_object_zh":"卷材类防水制品 E"},{"_id":"6a5a55f19af9f73f382512b0","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby hydroizolacyjne rolowe E","test_object_en":"Waterproofing sheet products E","methodology":"Wodoszczelność. Metoda ciśnieniowa","methodology_en":"Watertightness. Pressure method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność. Metoda ciśnieniowa","reference":"PN-EN 1928 „N\"","norm_bases":["PN-EN 1928 „N\""],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby hydroizolacyjne rolowe E Wodoszczelność. Metoda ciśnieniowa PN-EN 1928 „N\" Wyroby hydroizolacyjne rolowe E Wodoszczelnosc. Metoda cisnieniowa PN-EN 1928 „N\"","categories":["other"],"row_index":924,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waterproofing sheet products E Watertightness. Pressure method PN-EN 1928 „N\"","search_zh":"卷材类防水制品 E PN-EN 1928 „N\"","test_object_zh":"卷材类防水制品 E"},{"_id":"6a5a55f19af9f73f382512b1","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Działanie ciekłych chemikaliów i wody","methodology_en":"Action of liquid chemicals and water","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Działanie ciekłych chemikaliów i wody","reference":"PN-EN 1847","norm_bases":["PN-EN 1847"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Działanie ciekłych chemikaliów i wody PN-EN 1847 Wyroby z tworzyw sztucznych E Dzialanie cieklych chemikaliow i wody PN-EN 1847","categories":["water"],"row_index":925,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Action of liquid chemicals and water PN-EN 1847","search_zh":"塑料制品 E PN-EN 1847","test_object_zh":"塑料制品 E"},{"_id":"6a5a55f19af9f73f382512b2","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Przesiąkanie wody","methodology_en":"Water seepage","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przesiąkanie wody","reference":"PN-EN 13111 „N”","norm_bases":["PN-EN 13111 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Przesiąkanie wody PN-EN 13111 „N” Wyroby z tworzyw sztucznych E Przesiakanie wody PN-EN 13111 „N”","categories":["water"],"row_index":926,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Water seepage PN-EN 13111 „N”","search_zh":"塑料制品 E PN-EN 13111 „N”","test_object_zh":"塑料制品 E"},{"_id":"6a5a55f19af9f73f382512b3","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Wodoszczelność Metoda ciśnieniowa Zakres: do 1,2 MPa","methodology_en":"Watertightness Pressure method Range: up to 1,2 MPa","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność Metoda ciśnieniowa Zakres: do 1,2 MPa","reference":"PN-EN 1928 „N”","norm_bases":["PN-EN 1928 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Wodoszczelność Metoda ciśnieniowa Zakres: do 1,2 MPa PN-EN 1928 „N” Wyroby z tworzyw sztucznych E Wodoszczelnosc Metoda cisnieniowa Zakres: do 1,2 MPa PN-EN 1928 „N”","categories":["other"],"row_index":927,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Watertightness Pressure method Range: up to 1,2 MPa PN-EN 1928 „N”","search_zh":"塑料制品 E PN-EN 1928 „N”","test_object_zh":"塑料制品 E"},{"_id":"6a5a55f19af9f73f382512b4","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Przesiąkanie wody Metoda ciśnieniowa Zakres: do 1,2 MPa","methodology_en":"Water penetration Pressure method Range: up to 1,2 MPa","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przesiąkanie wody Metoda ciśnieniowa Zakres: do 1,2 MPa","reference":"PN-EN 13859-2 „N” PN-EN 13859-1 „N”","norm_bases":["PN-EN 13859-2 „N” PN-EN 13859-1 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Przesiąkanie wody Metoda ciśnieniowa Zakres: do 1,2 MPa PN-EN 13859-2 „N” PN-EN 13859-1 „N” Wyroby z tworzyw sztucznych E Przesiakanie wody Metoda cisnieniowa Zakres: do 1,2 MPa PN-EN 13859-2 „N” PN-EN 13859-1 „N”","categories":["water"],"row_index":928,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Water penetration Pressure method Range: up to 1,2 MPa PN-EN 13859-2 „N” PN-EN 13859-1 „N”","search_zh":"塑料制品 E PN-EN 13859-2 „N” PN-EN 13859-1 „N”","test_object_zh":"塑料制品 E"},{"_id":"6a5a55f19af9f73f382512b5","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych i kauczuku (folie, folie profilowane, tkaniny, tekstylia, włókniny, geomembrany, membrany, maty, taśmy, płyty, laminaty, uszczelki i inne) E","test_object_en":"Products of plastics and rubber (films, profiled films, fabrics, textiles, nonwovens, geomembranes, membranes, mats, tapes, sheets, laminates, gaskets and others) E","methodology":"Właściwości mechaniczne przy rozciąganiu Zakres: do 10 kN, trawersa do 1500 mm","methodology_en":"Tensile mechanical properties Range: up to 10 kN, crosshead travel up to 1500 mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Właściwości mechaniczne przy rozciąganiu Zakres: do 10 kN, trawersa do 1500 mm","reference":"PN-EN 12311-2","norm_bases":["PN-EN 12311-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych i kauczuku (folie, folie profilowane, tkaniny, tekstylia, włókniny, geomembrany, membrany, maty, taśmy, płyty, laminaty, uszczelki i inne) E Właściwości mechaniczne przy rozciąganiu Zakres: do 10 kN, trawersa do 1500 mm PN-EN 12311-2 Wyroby z tworzyw sztucznych i kauczuku (folie, folie profilowane, tkaniny, tekstylia, wlokniny, geomembrany, membrany, maty, tasmy, plyty, laminaty, uszczelki i inne) E Wlasciwosci mechaniczne przy rozciaganiu Zakres: do 10 kN, trawersa do 1500 mm PN-EN 12311-2","categories":["materials"],"row_index":929,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Products of plastics and rubber (films, profiled films, fabrics, textiles, nonwovens, geomembranes, membranes, mats, tapes, sheets, laminates, gaskets and others) E Tensile mechanical properties Range: up to 10 kN, crosshead travel up to 1500 mm PN-EN 12311-2","search_zh":"塑料与橡胶制品（薄膜、异型膜、织物、纺织品、非织造布、土工膜、防水膜、垫材、胶带、板材、层积板、密封件及其他）E PN-EN 12311-2","test_object_zh":"塑料与橡胶制品（薄膜、异型膜、织物、纺织品、非织造布、土工膜、防水膜、垫材、胶带、板材、层积板、密封件及其他）E"},{"_id":"6a5a55f19af9f73f382512b6","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych i kauczuku (folie, folie profilowane, tkaniny, tekstylia, włókniny, geomembrany, membrany, maty, taśmy, płyty, laminaty, uszczelki i inne) E","test_object_en":"Products of plastics and rubber (films, profiled films, fabrics, textiles, nonwovens, geomembranes, membranes, mats, tapes, sheets, laminates, gaskets and others) E","methodology":"Właściwości mechaniczne przy rozciąganiu – z wyjątkiem modułu sprężystości Zakres: do 10 kN i wydłużenie do 1500mm / do 50 kN i wydłużenie (6 - 60) mm","methodology_en":"Tensile mechanical properties – except for the modulus of elasticity Range: up to 10 kN and elongation up to 1500mm / up to 50 kN and elongation (6 - 60) mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Właściwości mechaniczne przy rozciąganiu – z wyjątkiem modułu sprężystości Zakres: do 10 kN i wydłużenie do 1500mm / do 50 kN i wydłużenie (6 - 60) mm","reference":"PN-EN ISO 527-1 „N” PN-EN ISO 527-2 PN-EN ISO 527-3","norm_bases":["PN-EN ISO 527-1 „N” PN-EN ISO 527-2 PN-EN ISO 527-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych i kauczuku (folie, folie profilowane, tkaniny, tekstylia, włókniny, geomembrany, membrany, maty, taśmy, płyty, laminaty, uszczelki i inne) E Właściwości mechaniczne przy rozciąganiu – z wyjątkiem modułu sprężystości Zakres: do 10 kN i wydłużenie do 1500mm / do 50 kN i wydłużenie (6 - 60) mm PN-EN ISO 527-1 „N” PN-EN ISO 527-2 PN-EN ISO 527-3 Wyroby z tworzyw sztucznych i kauczuku (folie, folie profilowane, tkaniny, tekstylia, wlokniny, geomembrany, membrany, maty, tasmy, plyty, laminaty, uszczelki i inne) E Wlasciwosci mechaniczne przy rozciaganiu – z wyjatkiem modulu sprezystosci Zakres: do 10 kN i wydluzenie do 1500mm / do 50 kN i wydluzenie (6 - 60) mm PN-EN ISO 527-1 „N” PN-EN ISO 527-2 PN-EN ISO 527-3","categories":["materials"],"row_index":930,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Products of plastics and rubber (films, profiled films, fabrics, textiles, nonwovens, geomembranes, membranes, mats, tapes, sheets, laminates, gaskets and others) E Tensile mechanical properties – except for the modulus of elasticity Range: up to 10 kN and elongation up to 1500mm / up to 50 kN and elongation (6 - 60) mm PN-EN ISO 527-1 „N” PN-EN ISO 527-2 PN-EN ISO 527-3","search_zh":"塑料与橡胶制品（薄膜、异型膜、织物、纺织品、非织造布、土工膜、防水膜、垫材、胶带、板材、层积板、密封件及其他）E PN-EN ISO 527-1 „N” PN-EN ISO 527-2 PN-EN ISO 527-3","test_object_zh":"塑料与橡胶制品（薄膜、异型膜、织物、纺织品、非织造布、土工膜、防水膜、垫材、胶带、板材、层积板、密封件及其他）E"},{"_id":"6a5a55f19af9f73f382512b7","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych i kauczuku (folie, folie profilowane, tkaniny, tekstylia, włókniny, geomembrany, membrany, maty, taśmy, płyty, laminaty, uszczelki i inne) E","test_object_en":"Products of plastics and rubber (films, profiled films, fabrics, textiles, nonwovens, geomembranes, membranes, mats, tapes, sheets, laminates, gaskets and others) E","methodology":"Wytrzymałość na rozdzieranie Zakres: do 10 kN","methodology_en":"Tear resistance Range: up to 10 kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na rozdzieranie Zakres: do 10 kN","reference":"PN-EN 12310-2","norm_bases":["PN-EN 12310-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych i kauczuku (folie, folie profilowane, tkaniny, tekstylia, włókniny, geomembrany, membrany, maty, taśmy, płyty, laminaty, uszczelki i inne) E Wytrzymałość na rozdzieranie Zakres: do 10 kN PN-EN 12310-2 Wyroby z tworzyw sztucznych i kauczuku (folie, folie profilowane, tkaniny, tekstylia, wlokniny, geomembrany, membrany, maty, tasmy, plyty, laminaty, uszczelki i inne) E Wytrzymalosc na rozdzieranie Zakres: do 10 kN PN-EN 12310-2","categories":["materials"],"row_index":931,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Products of plastics and rubber (films, profiled films, fabrics, textiles, nonwovens, geomembranes, membranes, mats, tapes, sheets, laminates, gaskets and others) E Tear resistance Range: up to 10 kN PN-EN 12310-2","search_zh":"塑料与橡胶制品（薄膜、异型膜、织物、纺织品、非织造布、土工膜、防水膜、垫材、胶带、板材、层积板、密封件及其他）E PN-EN 12310-2","test_object_zh":"塑料与橡胶制品（薄膜、异型膜、织物、纺织品、非织造布、土工膜、防水膜、垫材、胶带、板材、层积板、密封件及其他）E"},{"_id":"6a5a55f19af9f73f382512b8","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych i kauczuku (folie, folie profilowane, tkaniny, tekstylia, włókniny, geomembrany, membrany, maty, taśmy, płyty, laminaty, uszczelki i inne) E","test_object_en":"Products of plastics and rubber (films, profiled films, fabrics, textiles, nonwovens, geomembranes, membranes, mats, tapes, sheets, laminates, gaskets and others) E","methodology":"Wytrzymałość złączy na oddzieranie Zakres: do 10kN","methodology_en":"Peel strength of the joints Range: up to 10kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość złączy na oddzieranie Zakres: do 10kN","reference":"PN-EN 12316-2","norm_bases":["PN-EN 12316-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych i kauczuku (folie, folie profilowane, tkaniny, tekstylia, włókniny, geomembrany, membrany, maty, taśmy, płyty, laminaty, uszczelki i inne) E Wytrzymałość złączy na oddzieranie Zakres: do 10kN PN-EN 12316-2 Wyroby z tworzyw sztucznych i kauczuku (folie, folie profilowane, tkaniny, tekstylia, wlokniny, geomembrany, membrany, maty, tasmy, plyty, laminaty, uszczelki i inne) E Wytrzymalosc zlaczy na oddzieranie Zakres: do 10kN PN-EN 12316-2","categories":["materials"],"row_index":932,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Products of plastics and rubber (films, profiled films, fabrics, textiles, nonwovens, geomembranes, membranes, mats, tapes, sheets, laminates, gaskets and others) E Peel strength of the joints Range: up to 10kN PN-EN 12316-2","search_zh":"塑料与橡胶制品（薄膜、异型膜、织物、纺织品、非织造布、土工膜、防水膜、垫材、胶带、板材、层积板、密封件及其他）E PN-EN 12316-2","test_object_zh":"塑料与橡胶制品（薄膜、异型膜、织物、纺织品、非织造布、土工膜、防水膜、垫材、胶带、板材、层积板、密封件及其他）E"},{"_id":"6a5a55f19af9f73f382512b9","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych i kauczuku (folie, folie profilowane, tkaniny, tekstylia, włókniny, geomembrany, membrany, maty, taśmy, płyty, laminaty, uszczelki i inne) E","test_object_en":"Products of plastics and rubber (films, profiled films, fabrics, textiles, nonwovens, geomembranes, membranes, mats, tapes, sheets, laminates, gaskets and others) E","methodology":"Wytrzymałość złączy na ścinanie Zakres: do 10kN","methodology_en":"Shear strength of the joints Range: up to 10kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość złączy na ścinanie Zakres: do 10kN","reference":"PN-EN 12317-2","norm_bases":["PN-EN 12317-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych i kauczuku (folie, folie profilowane, tkaniny, tekstylia, włókniny, geomembrany, membrany, maty, taśmy, płyty, laminaty, uszczelki i inne) E Wytrzymałość złączy na ścinanie Zakres: do 10kN PN-EN 12317-2 Wyroby z tworzyw sztucznych i kauczuku (folie, folie profilowane, tkaniny, tekstylia, wlokniny, geomembrany, membrany, maty, tasmy, plyty, laminaty, uszczelki i inne) E Wytrzymalosc zlaczy na scinanie Zakres: do 10kN PN-EN 12317-2","categories":["materials"],"row_index":933,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Products of plastics and rubber (films, profiled films, fabrics, textiles, nonwovens, geomembranes, membranes, mats, tapes, sheets, laminates, gaskets and others) E Shear strength of the joints Range: up to 10kN PN-EN 12317-2","search_zh":"塑料与橡胶制品（薄膜、异型膜、织物、纺织品、非织造布、土工膜、防水膜、垫材、胶带、板材、层积板、密封件及其他）E PN-EN 12317-2","test_object_zh":"塑料与橡胶制品（薄膜、异型膜、织物、纺织品、非织造布、土工膜、防水膜、垫材、胶带、板材、层积板、密封件及其他）E"},{"_id":"6a5a55f19af9f73f382512ba","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby uszczelniające i kity E","test_object_en":"Sealing products and putties E","methodology":"Odporność na spływanie","methodology_en":"Resistance to sagging","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na spływanie","reference":"PN-EN ISO 7390 „N”","norm_bases":["PN-EN ISO 7390 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby uszczelniające i kity E Odporność na spływanie PN-EN ISO 7390 „N” Wyroby uszczelniajace i kity E Odpornosc na splywanie PN-EN ISO 7390 „N”","categories":["other"],"row_index":934,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sealing products and putties E Resistance to sagging PN-EN ISO 7390 „N”","search_zh":"密封制品与嵌缝膏 E PN-EN ISO 7390 „N”","test_object_zh":"密封制品与嵌缝膏 E"},{"_id":"6a5a55f19af9f73f382512bb","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby uszczelniające i kity E","test_object_en":"Sealing products and putties E","methodology":"Powrót elastyczny Zakres: do 10 kN, trawersa do 1500 mm","methodology_en":"Elastic recovery Range: up to 10 kN, crosshead up to 1500 mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Powrót elastyczny Zakres: do 10 kN, trawersa do 1500 mm","reference":"PN-EN ISO 7389","norm_bases":["PN-EN ISO 7389"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby uszczelniające i kity E Powrót elastyczny Zakres: do 10 kN, trawersa do 1500 mm PN-EN ISO 7389 Wyroby uszczelniajace i kity E Powrot elastyczny Zakres: do 10 kN, trawersa do 1500 mm PN-EN ISO 7389","categories":["other"],"row_index":935,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sealing products and putties E Elastic recovery Range: up to 10 kN, crosshead up to 1500 mm PN-EN ISO 7389","search_zh":"密封制品与嵌缝膏 E PN-EN ISO 7389","test_object_zh":"密封制品与嵌缝膏 E"},{"_id":"6a5a55f19af9f73f382512bc","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby uszczelniające i kity E","test_object_en":"Sealing products and putties E","methodology":"Właściwości adhezji / kohezji w stałej temperaturze Zakres: do 10 kN, trawersa do 1500 mm","methodology_en":"Adhesion / cohesion properties at constant temperature Range: up to 10 kN, crosshead travel up to 1500 mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Właściwości adhezji / kohezji w stałej temperaturze Zakres: do 10 kN, trawersa do 1500 mm","reference":"PN-EN ISO 9046 „N”","norm_bases":["PN-EN ISO 9046 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby uszczelniające i kity E Właściwości adhezji / kohezji w stałej temperaturze Zakres: do 10 kN, trawersa do 1500 mm PN-EN ISO 9046 „N” Wyroby uszczelniajace i kity E Wlasciwosci adhezji / kohezji w stalej temperaturze Zakres: do 10 kN, trawersa do 1500 mm PN-EN ISO 9046 „N”","categories":["other"],"row_index":936,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sealing products and putties E Adhesion / cohesion properties at constant temperature Range: up to 10 kN, crosshead travel up to 1500 mm PN-EN ISO 9046 „N”","search_zh":"密封制品与嵌缝膏 E PN-EN ISO 9046 „N”","test_object_zh":"密封制品与嵌缝膏 E"},{"_id":"6a5a55f19af9f73f382512bd","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby uszczelniające i kity E","test_object_en":"Sealing products and putties E","methodology":"Właściwości adhezji / kohezji w zmiennych temperaturach Zakres: do 10 kN, trawersa do 1500 mm","methodology_en":"Adhesion / cohesion properties at variable temperatures Range: up to 10 kN, crosshead travel up to 1500 mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Właściwości adhezji / kohezji w zmiennych temperaturach Zakres: do 10 kN, trawersa do 1500 mm","reference":"PN-EN ISO 9047 „N”","norm_bases":["PN-EN ISO 9047 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby uszczelniające i kity E Właściwości adhezji / kohezji w zmiennych temperaturach Zakres: do 10 kN, trawersa do 1500 mm PN-EN ISO 9047 „N” Wyroby uszczelniajace i kity E Wlasciwosci adhezji / kohezji w zmiennych temperaturach Zakres: do 10 kN, trawersa do 1500 mm PN-EN ISO 9047 „N”","categories":["other"],"row_index":937,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sealing products and putties E Adhesion / cohesion properties at variable temperatures Range: up to 10 kN, crosshead travel up to 1500 mm PN-EN ISO 9047 „N”","search_zh":"密封制品与嵌缝膏 E PN-EN ISO 9047 „N”","test_object_zh":"密封制品与嵌缝膏 E"},{"_id":"6a5a55f19af9f73f382512be","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby uszczelniające i kity E","test_object_en":"Sealing products and putties E","methodology":"Właściwości adhezji/kohezji kitów po działaniu ciepła, wody i sztucznego światła działającego przez szkło Zakres: do 10 kN, trawersa do 1500 mm","methodology_en":"Adhesion/cohesion properties of sealants after exposure to heat, water and artificial light through glass Range: up to 10 kN, crosshead travel up to 1500 mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Właściwości adhezji/kohezji kitów po działaniu ciepła, wody i sztucznego światła działającego przez szkło Zakres: do 10 kN, trawersa do 1500 mm","reference":"PN-EN ISO 11431 „N”","norm_bases":["PN-EN ISO 11431 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby uszczelniające i kity E Właściwości adhezji/kohezji kitów po działaniu ciepła, wody i sztucznego światła działającego przez szkło Zakres: do 10 kN, trawersa do 1500 mm PN-EN ISO 11431 „N” Wyroby uszczelniajace i kity E Wlasciwosci adhezji/kohezji kitow po dzialaniu ciepla, wody i sztucznego swiatla dzialajacego przez szklo Zakres: do 10 kN, trawersa do 1500 mm PN-EN ISO 11431 „N”","categories":["water"],"row_index":938,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sealing products and putties E Adhesion/cohesion properties of sealants after exposure to heat, water and artificial light through glass Range: up to 10 kN, crosshead travel up to 1500 mm PN-EN ISO 11431 „N”","search_zh":"密封制品与嵌缝膏 E PN-EN ISO 11431 „N”","test_object_zh":"密封制品与嵌缝膏 E"},{"_id":"6a5a55f19af9f73f382512bf","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby uszczelniające i kity E","test_object_en":"Sealing products and putties E","methodology":"Właściwości adhezji-kohezji po działaniu wody Zakres: do 10 kN, trawersa do 1500 mm","methodology_en":"Adhesion-cohesion properties after exposure to water Range: up to 10 kN, crosshead travel up to 1500 mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Właściwości adhezji-kohezji po działaniu wody Zakres: do 10 kN, trawersa do 1500 mm","reference":"PN-EN ISO10590 „N” PN-EN ISO 10591 „N”","norm_bases":["PN-EN ISO10590 „N” PN-EN ISO 10591 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby uszczelniające i kity E Właściwości adhezji-kohezji po działaniu wody Zakres: do 10 kN, trawersa do 1500 mm PN-EN ISO10590 „N” PN-EN ISO 10591 „N” Wyroby uszczelniajace i kity E Wlasciwosci adhezji-kohezji po dzialaniu wody Zakres: do 10 kN, trawersa do 1500 mm PN-EN ISO10590 „N” PN-EN ISO 10591 „N”","categories":["water"],"row_index":939,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sealing products and putties E Adhesion-cohesion properties after exposure to water Range: up to 10 kN, crosshead travel up to 1500 mm PN-EN ISO10590 „N” PN-EN ISO 10591 „N”","search_zh":"密封制品与嵌缝膏 E PN-EN ISO10590 „N” PN-EN ISO 10591 „N”","test_object_zh":"密封制品与嵌缝膏 E"},{"_id":"6a5a55f19af9f73f382512c0","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby uszczelniające i kity E","test_object_en":"Sealing products and putties E","methodology":"Właściwości mechaniczne przy rozciąganiu Zakres: do 10 kN, Trawersa do 1500 mm","methodology_en":"Tensile mechanical properties Range: up to 10 kN, Crosshead travel up to 1500 mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Właściwości mechaniczne przy rozciąganiu Zakres: do 10 kN, Trawersa do 1500 mm","reference":"PN-EN ISO 8339 „N”","norm_bases":["PN-EN ISO 8339 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby uszczelniające i kity E Właściwości mechaniczne przy rozciąganiu Zakres: do 10 kN, Trawersa do 1500 mm PN-EN ISO 8339 „N” Wyroby uszczelniajace i kity E Wlasciwosci mechaniczne przy rozciaganiu Zakres: do 10 kN, Trawersa do 1500 mm PN-EN ISO 8339 „N”","categories":["other"],"row_index":940,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sealing products and putties E Tensile mechanical properties Range: up to 10 kN, Crosshead travel up to 1500 mm PN-EN ISO 8339 „N”","search_zh":"密封制品与嵌缝膏 E PN-EN ISO 8339 „N”","test_object_zh":"密封制品与嵌缝膏 E"},{"_id":"6a5a55f19af9f73f382512c1","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby uszczelniające i kity E","test_object_en":"Sealing products and putties E","methodology":"Właściwości mechaniczne przy stałym rozciąganiu Zakres: do 10 kN, trawersa do 1500 mm","methodology_en":"Mechanical properties under constant tension Range: up to 10 kN, crosshead travel up to 1500 mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Właściwości mechaniczne przy stałym rozciąganiu Zakres: do 10 kN, trawersa do 1500 mm","reference":"PN-EN ISO 8340 „N”","norm_bases":["PN-EN ISO 8340 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby uszczelniające i kity E Właściwości mechaniczne przy stałym rozciąganiu Zakres: do 10 kN, trawersa do 1500 mm PN-EN ISO 8340 „N” Wyroby uszczelniajace i kity E Wlasciwosci mechaniczne przy stalym rozciaganiu Zakres: do 10 kN, trawersa do 1500 mm PN-EN ISO 8340 „N”","categories":["other"],"row_index":941,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sealing products and putties E Mechanical properties under constant tension Range: up to 10 kN, crosshead travel up to 1500 mm PN-EN ISO 8340 „N”","search_zh":"密封制品与嵌缝膏 E PN-EN ISO 8340 „N”","test_object_zh":"密封制品与嵌缝膏 E"},{"_id":"6a5a55f19af9f73f382512c2","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby uszczelniające i kity E","test_object_en":"Sealing products and putties E","methodology":"Zmiana masy i objętości Zakres: do 2100 g","methodology_en":"Change in mass and volume Range: up to 2100 g","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zmiana masy i objętości Zakres: do 2100 g","reference":"PN-EN ISO 10563 „N”","norm_bases":["PN-EN ISO 10563 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby uszczelniające i kity E Zmiana masy i objętości Zakres: do 2100 g PN-EN ISO 10563 „N” Wyroby uszczelniajace i kity E Zmiana masy i objetosci Zakres: do 2100 g PN-EN ISO 10563 „N”","categories":["other"],"row_index":942,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sealing products and putties E Change in mass and volume Range: up to 2100 g PN-EN ISO 10563 „N”","search_zh":"密封制品与嵌缝膏 E PN-EN ISO 10563 „N”","test_object_zh":"密封制品与嵌缝膏 E"},{"_id":"6a5a55f19af9f73f382512c3","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby hydroizolacyjne w postaci płynnej lub powłoki E","test_object_en":"Waterproofing products in liquid or coating form E","methodology":"Wodoszczelność Metoda ciśnieniowa Zakres: do 1,2 MPa","methodology_en":"Watertightness Pressure method Range: up to 1,2 MPa","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność Metoda ciśnieniowa Zakres: do 1,2 MPa","reference":"PN-EN 14891 „N” PN-EN 15820 „N”","norm_bases":["PN-EN 14891 „N” PN-EN 15820 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby hydroizolacyjne w postaci płynnej lub powłoki E Wodoszczelność Metoda ciśnieniowa Zakres: do 1,2 MPa PN-EN 14891 „N” PN-EN 15820 „N” Wyroby hydroizolacyjne w postaci plynnej lub powloki E Wodoszczelnosc Metoda cisnieniowa Zakres: do 1,2 MPa PN-EN 14891 „N” PN-EN 15820 „N”","categories":["other"],"row_index":943,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waterproofing products in liquid or coating form E Watertightness Pressure method Range: up to 1,2 MPa PN-EN 14891 „N” PN-EN 15820 „N”"},{"_id":"6a5a55f19af9f73f382512c4","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Podłogi, posadzki i nawierzchnie E","test_object_en":"Floors, floorings and pavements E","methodology":"Odporność na poślizg, próba wahadła także in situ","methodology_en":"Slip resistance, pendulum test also in situ","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na poślizg, próba wahadła także in situ","reference":"PN-EN 13036-4","norm_bases":["PN-EN 13036-4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podłogi, posadzki i nawierzchnie E Odporność na poślizg, próba wahadła także in situ PN-EN 13036-4 Podlogi, posadzki i nawierzchnie E Odpornosc na poslizg, proba wahadla takze in situ PN-EN 13036-4","categories":["construction"],"row_index":944,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Floors, floorings and pavements E Slip resistance, pendulum test also in situ PN-EN 13036-4","search_zh":"地板、地面与面层 E PN-EN 13036-4","test_object_zh":"地板、地面与面层 E"},{"_id":"6a5a55f19af9f73f382512c5","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Podłogi, posadzki i nawierzchnie E","test_object_en":"Floors, floorings and pavements E","methodology":"Odporność na poślizg także in situ","methodology_en":"Slip resistance also in situ","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na poślizg także in situ","reference":"EN/TS 15676","norm_bases":["EN/TS 15676"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podłogi, posadzki i nawierzchnie E Odporność na poślizg także in situ EN/TS 15676 Podlogi, posadzki i nawierzchnie E Odpornosc na poslizg takze in situ EN/TS 15676","categories":["construction"],"row_index":945,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Floors, floorings and pavements E Slip resistance also in situ EN/TS 15676","search_zh":"地板、地面与面层 E EN/TS 15676","test_object_zh":"地板、地面与面层 E"},{"_id":"6a5a55f19af9f73f382512c6","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Podłogi, posadzki i nawierzchnie E","test_object_en":"Floors, floorings and pavements E","methodology":"Odporność na poślizg, próba wahadła także in situ","methodology_en":"Slip resistance, pendulum test also in situ","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na poślizg, próba wahadła także in situ","reference":"PN-EN 14231","norm_bases":["PN-EN 14231"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podłogi, posadzki i nawierzchnie E Odporność na poślizg, próba wahadła także in situ PN-EN 14231 Podlogi, posadzki i nawierzchnie E Odpornosc na poslizg, proba wahadla takze in situ PN-EN 14231","categories":["construction"],"row_index":946,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Floors, floorings and pavements E Slip resistance, pendulum test also in situ PN-EN 14231","search_zh":"地板、地面与面层 E PN-EN 14231","test_object_zh":"地板、地面与面层 E"},{"_id":"6a5a55f19af9f73f382512c7","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Systemy izolacji cieplnej i ich komponenty E","test_object_en":"Thermal insulation systems and their components E","methodology":"Wytrzymałość na ścinanie początkowa Zakres: do 10 kN","methodology_en":"Initial shear strength Range: up to 10 kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ścinanie początkowa Zakres: do 10 kN","reference":"PN-EN 12004-2","norm_bases":["PN-EN 12004-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Systemy izolacji cieplnej i ich komponenty E Wytrzymałość na ścinanie początkowa Zakres: do 10 kN PN-EN 12004-2 Systemy izolacji cieplnej i ich komponenty E Wytrzymalosc na scinanie poczatkowa Zakres: do 10 kN PN-EN 12004-2","categories":["construction"],"row_index":947,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation systems and their components E Initial shear strength Range: up to 10 kN PN-EN 12004-2","search_zh":"隔热系统及其组件 E PN-EN 12004-2","test_object_zh":"隔热系统及其组件 E"},{"_id":"6a5a55f19af9f73f382512c8","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Systemy izolacji cieplnej i ich komponenty E","test_object_en":"Thermal insulation systems and their components E","methodology":"Wytrzymałość na ścinanie w podwyższonej temperaturze Zakres: do 10 kN","methodology_en":"Shear strength at elevated temperature Range: up to 10 kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ścinanie w podwyższonej temperaturze Zakres: do 10 kN","reference":"PN-EN 12004-2","norm_bases":["PN-EN 12004-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Systemy izolacji cieplnej i ich komponenty E Wytrzymałość na ścinanie w podwyższonej temperaturze Zakres: do 10 kN PN-EN 12004-2 Systemy izolacji cieplnej i ich komponenty E Wytrzymalosc na scinanie w podwyzszonej temperaturze Zakres: do 10 kN PN-EN 12004-2","categories":["construction"],"row_index":948,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation systems and their components E Shear strength at elevated temperature Range: up to 10 kN PN-EN 12004-2","search_zh":"隔热系统及其组件 E PN-EN 12004-2","test_object_zh":"隔热系统及其组件 E"},{"_id":"6a5a55f19af9f73f382512c9","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Systemy izolacji cieplnej i ich komponenty E","test_object_en":"Thermal insulation systems and their components E","methodology":"Wytrzymałość na ścinanie Zakres: do 10 kN","methodology_en":"Shear strength Range: up to 10 kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ścinanie Zakres: do 10 kN","reference":"PN-EN 12004-2","norm_bases":["PN-EN 12004-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Systemy izolacji cieplnej i ich komponenty E Wytrzymałość na ścinanie Zakres: do 10 kN PN-EN 12004-2 Systemy izolacji cieplnej i ich komponenty E Wytrzymalosc na scinanie Zakres: do 10 kN PN-EN 12004-2","categories":["construction"],"row_index":949,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation systems and their components E Shear strength Range: up to 10 kN PN-EN 12004-2","search_zh":"隔热系统及其组件 E PN-EN 12004-2","test_object_zh":"隔热系统及其组件 E"},{"_id":"6a5a55f19af9f73f382512ca","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Systemy izolacji cieplnej i ich komponenty E","test_object_en":"Thermal insulation systems and their components E","methodology":"Zawartość suchej substancji","methodology_en":"Dry matter content","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość suchej substancji","reference":"PN-EN 827","norm_bases":["PN-EN 827"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Systemy izolacji cieplnej i ich komponenty E Zawartość suchej substancji PN-EN 827 Systemy izolacji cieplnej i ich komponenty E Zawartosc suchej substancji PN-EN 827","categories":["construction"],"row_index":950,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation systems and their components E Dry matter content PN-EN 827","search_zh":"隔热系统及其组件 E 干物质含量 PN-EN 827","test_object_zh":"隔热系统及其组件 E","methodology_zh":"干物质含量"},{"_id":"6a5a55f19af9f73f382512cb","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Systemy izolacji cieplnej i ich komponenty E","test_object_en":"Thermal insulation systems and their components E","methodology":"Czas otwarty Zakres: do 16 kN Metoda pull off","methodology_en":"Open time Range: up to 16 kN Pull-off method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Czas otwarty Zakres: do 16 kN Metoda pull off","reference":"PN-EN 12004-2","norm_bases":["PN-EN 12004-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Systemy izolacji cieplnej i ich komponenty E Czas otwarty Zakres: do 16 kN Metoda pull off PN-EN 12004-2 Systemy izolacji cieplnej i ich komponenty E Czas otwarty Zakres: do 16 kN Metoda pull off PN-EN 12004-2","categories":["construction"],"row_index":951,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation systems and their components E Open time Range: up to 16 kN Pull-off method PN-EN 12004-2","search_zh":"隔热系统及其组件 E PN-EN 12004-2","test_object_zh":"隔热系统及其组件 E"},{"_id":"6a5a55f19af9f73f382512cc","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Systemy izolacji cieplnej i ich komponenty E","test_object_en":"Thermal insulation systems and their components E","methodology":"Odkształcenie poprzeczne","methodology_en":"Transverse deformation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odkształcenie poprzeczne","reference":"PN-EN 12004-2","norm_bases":["PN-EN 12004-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Systemy izolacji cieplnej i ich komponenty E Odkształcenie poprzeczne PN-EN 12004-2 Systemy izolacji cieplnej i ich komponenty E Odksztalcenie poprzeczne PN-EN 12004-2","categories":["construction"],"row_index":952,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation systems and their components E Transverse deformation PN-EN 12004-2","search_zh":"隔热系统及其组件 E 横向变形 PN-EN 12004-2","test_object_zh":"隔热系统及其组件 E","methodology_zh":"横向变形"},{"_id":"6a5a55f19af9f73f382512cd","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Systemy izolacji cieplnej i ich komponenty E","test_object_en":"Thermal insulation systems and their components E","methodology":"Przyczepność do materiału termoizolacyjnego Zakres: do 16 kN Metoda pull off","methodology_en":"Adhesion to thermal insulation material Range: up to 16 kN Pull-off method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przyczepność do materiału termoizolacyjnego Zakres: do 16 kN Metoda pull off","reference":"EAD 040083-XX-0404","norm_bases":["EAD 040083-XX-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Systemy izolacji cieplnej i ich komponenty E Przyczepność do materiału termoizolacyjnego Zakres: do 16 kN Metoda pull off EAD 040083-XX-0404 Systemy izolacji cieplnej i ich komponenty E Przyczepnosc do materialu termoizolacyjnego Zakres: do 16 kN Metoda pull off EAD 040083-XX-0404","categories":["materials","construction"],"row_index":953,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation systems and their components E Adhesion to thermal insulation material Range: up to 16 kN Pull-off method EAD 040083-XX-0404","search_zh":"隔热系统及其组件 E EAD 040083-XX-0404","test_object_zh":"隔热系统及其组件 E"},{"_id":"6a5a55f19af9f73f382512ce","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Systemy izolacji cieplnej i ich komponenty E","test_object_en":"Thermal insulation systems and their components E","methodology":"Przyczepność do podłoży Zakres: do 16 kN Metoda pull off","methodology_en":"Adhesion to substrates Range: up to 16 kN Pull-off method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przyczepność do podłoży Zakres: do 16 kN Metoda pull off","reference":"EAD 040083-XX-0404","norm_bases":["EAD 040083-XX-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Systemy izolacji cieplnej i ich komponenty E Przyczepność do podłoży Zakres: do 16 kN Metoda pull off EAD 040083-XX-0404 Systemy izolacji cieplnej i ich komponenty E Przyczepnosc do podlozy Zakres: do 16 kN Metoda pull off EAD 040083-XX-0404","categories":["construction"],"row_index":954,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation systems and their components E Adhesion to substrates Range: up to 16 kN Pull-off method EAD 040083-XX-0404","search_zh":"隔热系统及其组件 E EAD 040083-XX-0404","test_object_zh":"隔热系统及其组件 E"},{"_id":"6a5a55f19af9f73f382512cf","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Systemy izolacji cieplnej i ich komponenty E","test_object_en":"Thermal insulation systems and their components E","methodology":"Przyczepność po cyklach zamrażania i rozmrażania Zakres: do 16 kN Metoda pull off","methodology_en":"Adhesion after freeze-thaw cycles Range: up to 16 kN Pull off method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przyczepność po cyklach zamrażania i rozmrażania Zakres: do 16 kN Metoda pull off","reference":"PN-EN 12004-2","norm_bases":["PN-EN 12004-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Systemy izolacji cieplnej i ich komponenty E Przyczepność po cyklach zamrażania i rozmrażania Zakres: do 16 kN Metoda pull off PN-EN 12004-2 Systemy izolacji cieplnej i ich komponenty E Przyczepnosc po cyklach zamrazania i rozmrazania Zakres: do 16 kN Metoda pull off PN-EN 12004-2","categories":["construction"],"row_index":955,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation systems and their components E Adhesion after freeze-thaw cycles Range: up to 16 kN Pull off method PN-EN 12004-2","search_zh":"隔热系统及其组件 E PN-EN 12004-2","test_object_zh":"隔热系统及其组件 E"},{"_id":"6a5a55f19af9f73f382512d0","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Systemy izolacji cieplnej i ich komponenty E","test_object_en":"Thermal insulation systems and their components E","methodology":"Przyczepność po starzeniu termicznym Zakres: do 16 kN Metoda pull off","methodology_en":"Adhesion after thermal ageing Range: up to 16 kN Pull off method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przyczepność po starzeniu termicznym Zakres: do 16 kN Metoda pull off","reference":"PN-EN 12004-2","norm_bases":["PN-EN 12004-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Systemy izolacji cieplnej i ich komponenty E Przyczepność po starzeniu termicznym Zakres: do 16 kN Metoda pull off PN-EN 12004-2 Systemy izolacji cieplnej i ich komponenty E Przyczepnosc po starzeniu termicznym Zakres: do 16 kN Metoda pull off PN-EN 12004-2","categories":["construction"],"row_index":956,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation systems and their components E Adhesion after thermal ageing Range: up to 16 kN Pull off method PN-EN 12004-2","search_zh":"隔热系统及其组件 E PN-EN 12004-2","test_object_zh":"隔热系统及其组件 E"},{"_id":"6a5a55f19af9f73f382512d1","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Systemy izolacji cieplnej i ich komponenty E","test_object_en":"Thermal insulation systems and their components E","methodology":"Przyczepność po zanurzeniu w wodzie Zakres: do 16 kN Metoda pull off","methodology_en":"Adhesion after water immersion Range: up to 16 kN Pull off method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przyczepność po zanurzeniu w wodzie Zakres: do 16 kN Metoda pull off","reference":"PN-EN 12004-2","norm_bases":["PN-EN 12004-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Systemy izolacji cieplnej i ich komponenty E Przyczepność po zanurzeniu w wodzie Zakres: do 16 kN Metoda pull off PN-EN 12004-2 Systemy izolacji cieplnej i ich komponenty E Przyczepnosc po zanurzeniu w wodzie Zakres: do 16 kN Metoda pull off PN-EN 12004-2","categories":["construction"],"row_index":957,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation systems and their components E Adhesion after water immersion Range: up to 16 kN Pull off method PN-EN 12004-2","search_zh":"隔热系统及其组件 E PN-EN 12004-2","test_object_zh":"隔热系统及其组件 E"},{"_id":"6a5a55f19af9f73f382512d2","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Systemy izolacji cieplnej i ich komponenty E","test_object_en":"Thermal insulation systems and their components E","methodology":"Przyczepność początkowa (wytrzymałość pierwotna) Zakres: do 16 kN Metoda pull off","methodology_en":"Initial adhesion (initial strength) Range: up to 16 kN Pull off method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przyczepność początkowa (wytrzymałość pierwotna) Zakres: do 16 kN Metoda pull off","reference":"PN-EN 12004-2","norm_bases":["PN-EN 12004-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Systemy izolacji cieplnej i ich komponenty E Przyczepność początkowa (wytrzymałość pierwotna) Zakres: do 16 kN Metoda pull off PN-EN 12004-2 Systemy izolacji cieplnej i ich komponenty E Przyczepnosc poczatkowa (wytrzymalosc pierwotna) Zakres: do 16 kN Metoda pull off PN-EN 12004-2","categories":["construction"],"row_index":958,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation systems and their components E Initial adhesion (initial strength) Range: up to 16 kN Pull off method PN-EN 12004-2","search_zh":"隔热系统及其组件 E PN-EN 12004-2","test_object_zh":"隔热系统及其组件 E"},{"_id":"6a5a55f19af9f73f382512d3","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Systemy izolacji cieplnej i ich komponenty E","test_object_en":"Thermal insulation systems and their components E","methodology":"Przyczepność warstwy zbrojonej Zakres: do 16 kN Metoda pull off","methodology_en":"Adhesion of the reinforced layer Range: up to 16 kN Pull-off method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przyczepność warstwy zbrojonej Zakres: do 16 kN Metoda pull off","reference":"EAD 040083-XX-0404","norm_bases":["EAD 040083-XX-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Systemy izolacji cieplnej i ich komponenty E Przyczepność warstwy zbrojonej Zakres: do 16 kN Metoda pull off EAD 040083-XX-0404 Systemy izolacji cieplnej i ich komponenty E Przyczepnosc warstwy zbrojonej Zakres: do 16 kN Metoda pull off EAD 040083-XX-0404","categories":["construction"],"row_index":959,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation systems and their components E Adhesion of the reinforced layer Range: up to 16 kN Pull-off method EAD 040083-XX-0404","search_zh":"隔热系统及其组件 E EAD 040083-XX-0404","test_object_zh":"隔热系统及其组件 E"},{"_id":"6a5a55f19af9f73f382512d4","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Systemy izolacji cieplnej i ich komponenty E","test_object_en":"Thermal insulation systems and their components E","methodology":"Spływ (poślizg)","methodology_en":"Sagging (slip)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Spływ (poślizg)","reference":"PN-EN 12004-2","norm_bases":["PN-EN 12004-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Systemy izolacji cieplnej i ich komponenty E Spływ (poślizg) PN-EN 12004-2 Systemy izolacji cieplnej i ich komponenty E Splyw (poslizg) PN-EN 12004-2","categories":["construction"],"row_index":960,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation systems and their components E Sagging (slip) PN-EN 12004-2","search_zh":"隔热系统及其组件 E PN-EN 12004-2","test_object_zh":"隔热系统及其组件 E"},{"_id":"6a5a55f19af9f73f382512d5","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Systemy izolacji cieplnej i ich komponenty E","test_object_en":"Thermal insulation systems and their components E","methodology":"Wytrzymałość na ścinanie po starzeniu termicznym Zakres: do 10 kN","methodology_en":"Shear strength after thermal ageing Range: up to 10 kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ścinanie po starzeniu termicznym Zakres: do 10 kN","reference":"PN-EN 12004-2","norm_bases":["PN-EN 12004-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Systemy izolacji cieplnej i ich komponenty E Wytrzymałość na ścinanie po starzeniu termicznym Zakres: do 10 kN PN-EN 12004-2 Systemy izolacji cieplnej i ich komponenty E Wytrzymalosc na scinanie po starzeniu termicznym Zakres: do 10 kN PN-EN 12004-2","categories":["construction"],"row_index":961,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation systems and their components E Shear strength after thermal ageing Range: up to 10 kN PN-EN 12004-2","search_zh":"隔热系统及其组件 E PN-EN 12004-2","test_object_zh":"隔热系统及其组件 E"},{"_id":"6a5a55f19af9f73f382512d6","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Systemy izolacji cieplnej i ich komponenty E","test_object_en":"Thermal insulation systems and their components E","methodology":"Wytrzymałość na ścinanie po zanurzeniu w wodzie Zakres: do 10 kN","methodology_en":"Shear strength after immersion in water Range: up to 10 kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ścinanie po zanurzeniu w wodzie Zakres: do 10 kN","reference":"PN-EN 12004-2","norm_bases":["PN-EN 12004-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Systemy izolacji cieplnej i ich komponenty E Wytrzymałość na ścinanie po zanurzeniu w wodzie Zakres: do 10 kN PN-EN 12004-2 Systemy izolacji cieplnej i ich komponenty E Wytrzymalosc na scinanie po zanurzeniu w wodzie Zakres: do 10 kN PN-EN 12004-2","categories":["construction"],"row_index":962,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation systems and their components E Shear strength after immersion in water Range: up to 10 kN PN-EN 12004-2","search_zh":"隔热系统及其组件 E PN-EN 12004-2","test_object_zh":"隔热系统及其组件 E"},{"_id":"6a5a55f19af9f73f382512d7","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Systemy izolacji cieplnej i ich komponenty E","test_object_en":"Thermal insulation systems and their components E","methodology":"Masa powierzchniowa Metoda wagowa","methodology_en":"Mass per unit area Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Masa powierzchniowa Metoda wagowa","reference":"EAD 040016-00-0404","norm_bases":["EAD 040016-00-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Systemy izolacji cieplnej i ich komponenty E Masa powierzchniowa Metoda wagowa EAD 040016-00-0404 Systemy izolacji cieplnej i ich komponenty E Masa powierzchniowa Metoda wagowa EAD 040016-00-0404","categories":["construction"],"row_index":963,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation systems and their components E Mass per unit area Gravimetric method EAD 040016-00-0404","search_zh":"隔热系统及其组件 E EAD 040016-00-0404","test_object_zh":"隔热系统及其组件 E"},{"_id":"6a5a55f19af9f73f382512d8","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Systemy izolacji cieplnej i ich komponenty E","test_object_en":"Thermal insulation systems and their components E","methodology":"Siła zrywająca i wydłużenie względne (naprężenie zrywające i wydłużenie) Zakres: do 10 kN","methodology_en":"Breaking force and relative elongation (breaking stress and elongation) Range: up to 10 kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła zrywająca i wydłużenie względne (naprężenie zrywające i wydłużenie) Zakres: do 10 kN","reference":"EAD 040016-00-0404","norm_bases":["EAD 040016-00-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Systemy izolacji cieplnej i ich komponenty E Siła zrywająca i wydłużenie względne (naprężenie zrywające i wydłużenie) Zakres: do 10 kN EAD 040016-00-0404 Systemy izolacji cieplnej i ich komponenty E Sila zrywajaca i wydluzenie wzgledne (naprezenie zrywajace i wydluzenie) Zakres: do 10 kN EAD 040016-00-0404","categories":["construction"],"row_index":964,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation systems and their components E Breaking force and relative elongation (breaking stress and elongation) Range: up to 10 kN EAD 040016-00-0404","search_zh":"隔热系统及其组件 E EAD 040016-00-0404","test_object_zh":"隔热系统及其组件 E"},{"_id":"6a5a55f19af9f73f382512d9","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Systemy izolacji cieplnej i ich komponenty E","test_object_en":"Thermal insulation systems and their components E","methodology":"Strata prażenia / zawartość popiołu","methodology_en":"Loss on ignition / ash content","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Strata prażenia / zawartość popiołu","reference":"EAD 040016-00-0404","norm_bases":["EAD 040016-00-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Systemy izolacji cieplnej i ich komponenty E Strata prażenia / zawartość popiołu EAD 040016-00-0404 Systemy izolacji cieplnej i ich komponenty E Strata prazenia / zawartosc popiolu EAD 040016-00-0404","categories":["construction"],"row_index":965,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation systems and their components E Loss on ignition / ash content EAD 040016-00-0404","search_zh":"隔热系统及其组件 E EAD 040016-00-0404","test_object_zh":"隔热系统及其组件 E"},{"_id":"6a5a55f19af9f73f382512da","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Systemy izolacji cieplnej i ich komponenty E","test_object_en":"Thermal insulation systems and their components E","methodology":"Wymiar oczek","methodology_en":"Mesh size","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiar oczek","reference":"EAD 040016-00-0404","norm_bases":["EAD 040016-00-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Systemy izolacji cieplnej i ich komponenty E Wymiar oczek EAD 040016-00-0404 Systemy izolacji cieplnej i ich komponenty E Wymiar oczek EAD 040016-00-0404","categories":["construction"],"row_index":966,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation systems and their components E Mesh size EAD 040016-00-0404","search_zh":"隔热系统及其组件 E EAD 040016-00-0404","test_object_zh":"隔热系统及其组件 E"},{"_id":"6a5a55f19af9f73f382512db","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Systemy izolacji cieplnej i ich komponenty E","test_object_en":"Thermal insulation systems and their components E","methodology":"Absorpcja kapilarna (wodochłonność, podciąganie kapilarne wody) Zakres: do 12 kg Metoda wagowa","methodology_en":"Capillary absorption (water absorption, capillary rise of water) Range: up to 12 kg Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Absorpcja kapilarna (wodochłonność, podciąganie kapilarne wody) Zakres: do 12 kg Metoda wagowa","reference":"EAD 040083-XX-0404","norm_bases":["EAD 040083-XX-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Systemy izolacji cieplnej i ich komponenty E Absorpcja kapilarna (wodochłonność, podciąganie kapilarne wody) Zakres: do 12 kg Metoda wagowa EAD 040083-XX-0404 Systemy izolacji cieplnej i ich komponenty E Absorpcja kapilarna (wodochlonnosc, podciaganie kapilarne wody) Zakres: do 12 kg Metoda wagowa EAD 040083-XX-0404","categories":["water","construction"],"row_index":967,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation systems and their components E Capillary absorption (water absorption, capillary rise of water) Range: up to 12 kg Gravimetric method EAD 040083-XX-0404","search_zh":"隔热系统及其组件 E EAD 040083-XX-0404","test_object_zh":"隔热系统及其组件 E"},{"_id":"6a5a55f19af9f73f382512dc","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Systemy izolacji cieplnej i ich komponenty E","test_object_en":"Thermal insulation systems and their components E","methodology":"Mrozoodporność (cykle zamrażania i rozmrażania) metoda symulacyjna Metoda pull off","methodology_en":"Frost resistance (freeze-thaw cycles) simulation method Pull-off method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Mrozoodporność (cykle zamrażania i rozmrażania) metoda symulacyjna Metoda pull off","reference":"EAD 040083-XX-0404","norm_bases":["EAD 040083-XX-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Systemy izolacji cieplnej i ich komponenty E Mrozoodporność (cykle zamrażania i rozmrażania) metoda symulacyjna Metoda pull off EAD 040083-XX-0404 Systemy izolacji cieplnej i ich komponenty E Mrozoodpornosc (cykle zamrazania i rozmrazania) metoda symulacyjna Metoda pull off EAD 040083-XX-0404","categories":["construction"],"row_index":968,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation systems and their components E Frost resistance (freeze-thaw cycles) simulation method Pull-off method EAD 040083-XX-0404","search_zh":"隔热系统及其组件 E EAD 040083-XX-0404","test_object_zh":"隔热系统及其组件 E"},{"_id":"6a5a55f19af9f73f382512dd","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Systemy izolacji cieplnej i ich komponenty E","test_object_en":"Thermal insulation systems and their components E","methodology":"Odporność na starzenie","methodology_en":"Resistance to ageing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na starzenie","reference":"EAD 040083-XX-0404","norm_bases":["EAD 040083-XX-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Systemy izolacji cieplnej i ich komponenty E Odporność na starzenie EAD 040083-XX-0404 Systemy izolacji cieplnej i ich komponenty E Odpornosc na starzenie EAD 040083-XX-0404","categories":["construction"],"row_index":969,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation systems and their components E Resistance to ageing EAD 040083-XX-0404","search_zh":"隔热系统及其组件 E 耐老化性 EAD 040083-XX-0404","test_object_zh":"隔热系统及其组件 E","methodology_zh":"耐老化性"},{"_id":"6a5a55f19af9f73f382512de","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Systemy izolacji cieplnej i ich komponenty E","test_object_en":"Thermal insulation systems and their components E","methodology":"Odporność na uderzenie ciałem twardym","methodology_en":"Resistance to hard body impact","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie ciałem twardym","reference":"EAD 040083-XX-0404","norm_bases":["EAD 040083-XX-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Systemy izolacji cieplnej i ich komponenty E Odporność na uderzenie ciałem twardym EAD 040083-XX-0404 Systemy izolacji cieplnej i ich komponenty E Odpornosc na uderzenie cialem twardym EAD 040083-XX-0404","categories":["construction"],"row_index":970,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation systems and their components E Resistance to hard body impact EAD 040083-XX-0404","search_zh":"隔热系统及其组件 E 硬物撞击抗力 EAD 040083-XX-0404","test_object_zh":"隔热系统及其组件 E","methodology_zh":"硬物撞击抗力"},{"_id":"6a5a55f19af9f73f382512df","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Systemy izolacji cieplnej i ich komponenty E","test_object_en":"Thermal insulation systems and their components E","methodology":"Przepuszczalność pary wodnej (opór dyfuzyjny) Zakres: do 610 g","methodology_en":"Water vapour permeability (diffusion resistance) Range: up to 610 g","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność pary wodnej (opór dyfuzyjny) Zakres: do 610 g","reference":"XX-0404 | PN-EN 12086","norm_bases":["XX-0404","PN-EN 12086"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Systemy izolacji cieplnej i ich komponenty E Przepuszczalność pary wodnej (opór dyfuzyjny) Zakres: do 610 g XX-0404 | PN-EN 12086 Systemy izolacji cieplnej i ich komponenty E Przepuszczalnosc pary wodnej (opor dyfuzyjny) Zakres: do 610 g XX-0404 | PN-EN 12086","categories":["construction"],"row_index":971,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation systems and their components E Water vapour permeability (diffusion resistance) Range: up to 610 g XX-0404 | PN-EN 12086","search_zh":"隔热系统及其组件 E XX-0404 | PN-EN 12086","test_object_zh":"隔热系统及其组件 E"},{"_id":"6a5a55f19af9f73f382512e0","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Systemy izolacji cieplnej i ich komponenty E","test_object_en":"Thermal insulation systems and their components E","methodology":"Przyczepność międzywarstwowa Zakres: do 16 kN","methodology_en":"Interlayer adhesion Range: up to 16 kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przyczepność międzywarstwowa Zakres: do 16 kN","reference":"EAD 040083-XX-0404","norm_bases":["EAD 040083-XX-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Systemy izolacji cieplnej i ich komponenty E Przyczepność międzywarstwowa Zakres: do 16 kN EAD 040083-XX-0404 Systemy izolacji cieplnej i ich komponenty E Przyczepnosc miedzywarstwowa Zakres: do 16 kN EAD 040083-XX-0404","categories":["construction"],"row_index":972,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermal insulation systems and their components E Interlayer adhesion Range: up to 16 kN EAD 040083-XX-0404","search_zh":"隔热系统及其组件 E EAD 040083-XX-0404","test_object_zh":"隔热系统及其组件 E"},{"_id":"6a5a55f19af9f73f382512e1","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Odporność barwy na działanie światła","methodology_en":"Colour fastness to light","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność barwy na działanie światła","reference":"PN-EN ISO 105-B02","norm_bases":["PN-EN ISO 105-B02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Odporność barwy na działanie światła PN-EN ISO 105-B02 Wyroby z tworzyw sztucznych E Odpornosc barwy na dzialanie swiatla PN-EN ISO 105-B02","categories":["other"],"row_index":973,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Colour fastness to light PN-EN ISO 105-B02","search_zh":"塑料制品 E PN-EN ISO 105-B02","test_object_zh":"塑料制品 E"},{"_id":"6a5a55f19af9f73f382512e2","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty warstwowe E","test_object_en":"Sandwich panels E","methodology":"Moduł sprężystości poprzecznej przy zginaniu Zakres: do 30 kN Metoda wytrzymałościowa","methodology_en":"Shear modulus in bending Range: up to 30 kN Strength test method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moduł sprężystości poprzecznej przy zginaniu Zakres: do 30 kN Metoda wytrzymałościowa","reference":"PN-EN 14509","norm_bases":["PN-EN 14509"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty warstwowe E Moduł sprężystości poprzecznej przy zginaniu Zakres: do 30 kN Metoda wytrzymałościowa PN-EN 14509 Plyty warstwowe E Modul sprezystosci poprzecznej przy zginaniu Zakres: do 30 kN Metoda wytrzymalosciowa PN-EN 14509","categories":["other"],"row_index":974,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sandwich panels E Shear modulus in bending Range: up to 30 kN Strength test method PN-EN 14509","search_zh":"夹芯板 E PN-EN 14509","test_object_zh":"夹芯板 E"},{"_id":"6a5a55f19af9f73f382512e3","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty warstwowe E","test_object_en":"Sandwich panels E","methodology":"Moduł sprężystości przy rozciąganiu Zakres: (20 - 50000) N Metoda wytrzymałościowa","methodology_en":"Modulus of elasticity in tension Range: (20 - 50000) N Strength test method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moduł sprężystości przy rozciąganiu Zakres: (20 - 50000) N Metoda wytrzymałościowa","reference":"PN-EN 14509","norm_bases":["PN-EN 14509"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty warstwowe E Moduł sprężystości przy rozciąganiu Zakres: (20 - 50000) N Metoda wytrzymałościowa PN-EN 14509 Plyty warstwowe E Modul sprezystosci przy rozciaganiu Zakres: (20 - 50000) N Metoda wytrzymalosciowa PN-EN 14509","categories":["other"],"row_index":975,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sandwich panels E Modulus of elasticity in tension Range: (20 - 50000) N Strength test method PN-EN 14509","search_zh":"夹芯板 E PN-EN 14509","test_object_zh":"夹芯板 E"},{"_id":"6a5a55f19af9f73f382512e4","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty warstwowe E","test_object_en":"Sandwich panels E","methodology":"Moduł sprężystości przy ściskaniu Zakres: (20 - 50000) N Metoda wytrzymałościowa","methodology_en":"Modulus of elasticity in compression Range: (20 - 50000) N Strength test method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moduł sprężystości przy ściskaniu Zakres: (20 - 50000) N Metoda wytrzymałościowa","reference":"PN-EN ISO 29469 PN-EN 14509","norm_bases":["PN-EN ISO 29469 PN-EN 14509"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty warstwowe E Moduł sprężystości przy ściskaniu Zakres: (20 - 50000) N Metoda wytrzymałościowa PN-EN ISO 29469 PN-EN 14509 Plyty warstwowe E Modul sprezystosci przy sciskaniu Zakres: (20 - 50000) N Metoda wytrzymalosciowa PN-EN ISO 29469 PN-EN 14509","categories":["other"],"row_index":976,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sandwich panels E Modulus of elasticity in compression Range: (20 - 50000) N Strength test method PN-EN ISO 29469 PN-EN 14509","search_zh":"夹芯板 E PN-EN ISO 29469 PN-EN 14509","test_object_zh":"夹芯板 E"},{"_id":"6a5a55f19af9f73f382512e5","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty warstwowe E","test_object_en":"Sandwich panels E","methodology":"Moduł sprężystości przy rozciąganiu materiału rdzenia Zakres: do 30 kN Metoda wytrzymałościowa","methodology_en":"Modulus of elasticity in tension of the core material Range: up to 30 kN Strength test method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moduł sprężystości przy rozciąganiu materiału rdzenia Zakres: do 30 kN Metoda wytrzymałościowa","reference":"PN-EN 14509","norm_bases":["PN-EN 14509"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty warstwowe E Moduł sprężystości przy rozciąganiu materiału rdzenia Zakres: do 30 kN Metoda wytrzymałościowa PN-EN 14509 Plyty warstwowe E Modul sprezystosci przy rozciaganiu materialu rdzenia Zakres: do 30 kN Metoda wytrzymalosciowa PN-EN 14509","categories":["materials"],"row_index":977,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sandwich panels E Modulus of elasticity in tension of the core material Range: up to 30 kN Strength test method PN-EN 14509","search_zh":"夹芯板 E PN-EN 14509","test_object_zh":"夹芯板 E"},{"_id":"6a5a55f19af9f73f382512e6","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty warstwowe E","test_object_en":"Sandwich panels E","methodology":"Stabilność wymiarowa w określonych warunkach temperaturowych i wilgotnościowych zakres temperatur do 180°C, zakres wilg. wzgl.: (0 - 100)%","methodology_en":"Dimensional stability under specified temperature and humidity conditions temperature range up to 180°C, rel. humidity range: (0 - 100)%","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stabilność wymiarowa w określonych warunkach temperaturowych i wilgotnościowych zakres temperatur do 180°C, zakres wilg. wzgl.: (0 - 100)%","reference":"PN-EN 1604","norm_bases":["PN-EN 1604"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty warstwowe E Stabilność wymiarowa w określonych warunkach temperaturowych i wilgotnościowych zakres temperatur do 180°C, zakres wilg. wzgl.: (0 - 100)% PN-EN 1604 Plyty warstwowe E Stabilnosc wymiarowa w okreslonych warunkach temperaturowych i wilgotnosciowych zakres temperatur do 180°C, zakres wilg. wzgl.: (0 - 100)% PN-EN 1604","categories":["other"],"row_index":978,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sandwich panels E Dimensional stability under specified temperature and humidity conditions temperature range up to 180°C, rel. humidity range: (0 - 100)% PN-EN 1604","search_zh":"夹芯板 E PN-EN 1604","test_object_zh":"夹芯板 E"},{"_id":"6a5a55f19af9f73f382512e7","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty warstwowe E","test_object_en":"Sandwich panels E","methodology":"Wytrzymałość na rozciąganie Zakres: (20 - 50000) N","methodology_en":"Tensile strength Range: (20 - 50000) N","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na rozciąganie Zakres: (20 - 50000) N","reference":"PN-EN 1607 PN-EN 14509","norm_bases":["PN-EN 1607 PN-EN 14509"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty warstwowe E Wytrzymałość na rozciąganie Zakres: (20 - 50000) N PN-EN 1607 PN-EN 14509 Plyty warstwowe E Wytrzymalosc na rozciaganie Zakres: (20 - 50000) N PN-EN 1607 PN-EN 14509","categories":["other"],"row_index":979,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sandwich panels E Tensile strength Range: (20 - 50000) N PN-EN 1607 PN-EN 14509","search_zh":"夹芯板 E PN-EN 1607 PN-EN 14509","test_object_zh":"夹芯板 E"},{"_id":"6a5a55f19af9f73f382512e8","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty warstwowe E","test_object_en":"Sandwich panels E","methodology":"Wytrzymałość na ścinanie w układzie z próbką pojedynczą Zakres: (20 - 50000) N","methodology_en":"Shear strength in a single specimen arrangement Range: (20 - 50000) N","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ścinanie w układzie z próbką pojedynczą Zakres: (20 - 50000) N","reference":"PN-EN 12090","norm_bases":["PN-EN 12090"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty warstwowe E Wytrzymałość na ścinanie w układzie z próbką pojedynczą Zakres: (20 - 50000) N PN-EN 12090 Plyty warstwowe E Wytrzymalosc na scinanie w ukladzie z probka pojedyncza Zakres: (20 - 50000) N PN-EN 12090","categories":["other"],"row_index":980,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sandwich panels E Shear strength in a single specimen arrangement Range: (20 - 50000) N PN-EN 12090","search_zh":"夹芯板 E PN-EN 12090","test_object_zh":"夹芯板 E"},{"_id":"6a5a55f19af9f73f382512e9","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty warstwowe E","test_object_en":"Sandwich panels E","methodology":"Wytrzymałość na ścinanie Zakres: (20 - 50000) N","methodology_en":"Shear strength Range: (20 - 50000) N","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ścinanie Zakres: (20 - 50000) N","reference":"PN-EN 14509","norm_bases":["PN-EN 14509"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty warstwowe E Wytrzymałość na ścinanie Zakres: (20 - 50000) N PN-EN 14509 Plyty warstwowe E Wytrzymalosc na scinanie Zakres: (20 - 50000) N PN-EN 14509","categories":["other"],"row_index":981,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sandwich panels E Shear strength Range: (20 - 50000) N PN-EN 14509","search_zh":"夹芯板 E PN-EN 14509","test_object_zh":"夹芯板 E"},{"_id":"6a5a55f19af9f73f382512ea","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty warstwowe E","test_object_en":"Sandwich panels E","methodology":"Wytrzymałość na ściskanie lub naprężenia przy 10% odkształceniu względnym Zakres: (20 - 50000) N","methodology_en":"Compressive strength or stress at 10% relative deformation Range: (20 - 50000) N","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie lub naprężenia przy 10% odkształceniu względnym Zakres: (20 - 50000) N","reference":"PN-EN ISO 29469 PN-EN 14509","norm_bases":["PN-EN ISO 29469 PN-EN 14509"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty warstwowe E Wytrzymałość na ściskanie lub naprężenia przy 10% odkształceniu względnym Zakres: (20 - 50000) N PN-EN ISO 29469 PN-EN 14509 Plyty warstwowe E Wytrzymalosc na sciskanie lub naprezenia przy 10% odksztalceniu wzglednym Zakres: (20 - 50000) N PN-EN ISO 29469 PN-EN 14509","categories":["other"],"row_index":982,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sandwich panels E Compressive strength or stress at 10% relative deformation Range: (20 - 50000) N PN-EN ISO 29469 PN-EN 14509","search_zh":"夹芯板 E PN-EN ISO 29469 PN-EN 14509","test_object_zh":"夹芯板 E"},{"_id":"6a5a55f19af9f73f382512eb","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Podłogi, posadzki i nawierzchnie E","test_object_en":"Floors, floorings and pavements E","methodology":"Odporność chemiczna Metoda wagowa","methodology_en":"Chemical resistance Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność chemiczna Metoda wagowa","reference":"PN-EN ISO 175","norm_bases":["PN-EN ISO 175"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podłogi, posadzki i nawierzchnie E Odporność chemiczna Metoda wagowa PN-EN ISO 175 Podlogi, posadzki i nawierzchnie E Odpornosc chemiczna Metoda wagowa PN-EN ISO 175","categories":["construction"],"row_index":983,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Floors, floorings and pavements E Chemical resistance Gravimetric method PN-EN ISO 175","search_zh":"地板、地面与面层 E PN-EN ISO 175","test_object_zh":"地板、地面与面层 E"},{"_id":"6a5a55f19af9f73f382512ec","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Podłogi, posadzki i nawierzchnie E","test_object_en":"Floors, floorings and pavements E","methodology":"Właściwości przeciwpoślizgowe","methodology_en":"Anti-slip properties","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Właściwości przeciwpoślizgowe","reference":"DIN 51130","norm_bases":["DIN 51130"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podłogi, posadzki i nawierzchnie E Właściwości przeciwpoślizgowe DIN 51130 Podlogi, posadzki i nawierzchnie E Wlasciwosci przeciwposlizgowe DIN 51130","categories":["construction"],"row_index":984,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Floors, floorings and pavements E Anti-slip properties DIN 51130","search_zh":"地板、地面与面层 E DIN 51130","test_object_zh":"地板、地面与面层 E"},{"_id":"6a5a55f19af9f73f382512ed","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Tynki i zaprawy E","test_object_en":"Plasters and mortars E","methodology":"Opór dyfuzyjny względny Zakres: do 610 g","methodology_en":"Relative diffusion resistance Range: up to 610 g","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Opór dyfuzyjny względny Zakres: do 610 g","reference":"PN-EN ISO 7783","norm_bases":["PN-EN ISO 7783"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tynki i zaprawy E Opór dyfuzyjny względny Zakres: do 610 g PN-EN ISO 7783 Tynki i zaprawy E Opor dyfuzyjny wzgledny Zakres: do 610 g PN-EN ISO 7783","categories":["other"],"row_index":985,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plasters and mortars E Relative diffusion resistance Range: up to 610 g PN-EN ISO 7783","search_zh":"抹面砂浆与砌筑砂浆 E PN-EN ISO 7783","test_object_zh":"抹面砂浆与砌筑砂浆 E"},{"_id":"6a5a55f19af9f73f382512ee","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Tynki i zaprawy E","test_object_en":"Plasters and mortars E","methodology":"Przyczepność do podłoża stwardniałych zapraw na obrzutkę i do tynkowania Zakres: do 16 kN także in situ","methodology_en":"Adhesion to the substrate of hardened rendering and plastering mortars Range: up to 16 kN also in situ","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przyczepność do podłoża stwardniałych zapraw na obrzutkę i do tynkowania Zakres: do 16 kN także in situ","reference":"PN-EN 1015-12","norm_bases":["PN-EN 1015-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tynki i zaprawy E Przyczepność do podłoża stwardniałych zapraw na obrzutkę i do tynkowania Zakres: do 16 kN także in situ PN-EN 1015-12 Tynki i zaprawy E Przyczepnosc do podloza stwardnialych zapraw na obrzutke i do tynkowania Zakres: do 16 kN takze in situ PN-EN 1015-12","categories":["other"],"row_index":986,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plasters and mortars E Adhesion to the substrate of hardened rendering and plastering mortars Range: up to 16 kN also in situ PN-EN 1015-12","search_zh":"抹面砂浆与砌筑砂浆 E PN-EN 1015-12","test_object_zh":"抹面砂浆与砌筑砂浆 E"},{"_id":"6a5a55f19af9f73f382512ef","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Tynki i zaprawy E","test_object_en":"Plasters and mortars E","methodology":"Współczynnik absorpcji spowodowanej podciąganiem kapilarnym stwardniałej zaprawy Metoda wagowa","methodology_en":"Coefficient of water absorption due to capillary action of hardened mortar Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Współczynnik absorpcji spowodowanej podciąganiem kapilarnym stwardniałej zaprawy Metoda wagowa","reference":"PN-EN 1015-18","norm_bases":["PN-EN 1015-18"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tynki i zaprawy E Współczynnik absorpcji spowodowanej podciąganiem kapilarnym stwardniałej zaprawy Metoda wagowa PN-EN 1015-18 Tynki i zaprawy E Wspolczynnik absorpcji spowodowanej podciaganiem kapilarnym stwardnialej zaprawy Metoda wagowa PN-EN 1015-18","categories":["other"],"row_index":987,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plasters and mortars E Coefficient of water absorption due to capillary action of hardened mortar Gravimetric method PN-EN 1015-18","search_zh":"抹面砂浆与砌筑砂浆 E PN-EN 1015-18","test_object_zh":"抹面砂浆与砌筑砂浆 E"},{"_id":"6a5a55f19af9f73f382512f0","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Tynki i zaprawy E","test_object_en":"Plasters and mortars E","methodology":"Gęstość objętościowa Metoda wagowa","methodology_en":"Bulk density Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Gęstość objętościowa Metoda wagowa","reference":"PN-EN 1015-10","norm_bases":["PN-EN 1015-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tynki i zaprawy E Gęstość objętościowa Metoda wagowa PN-EN 1015-10 Tynki i zaprawy E Gestosc objetosciowa Metoda wagowa PN-EN 1015-10","categories":["other"],"row_index":988,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plasters and mortars E Bulk density Gravimetric method PN-EN 1015-10","search_zh":"抹面砂浆与砌筑砂浆 E PN-EN 1015-10","test_object_zh":"抹面砂浆与砌筑砂浆 E"},{"_id":"6a5a55f19af9f73f382512f1","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Tynki i zaprawy E","test_object_en":"Plasters and mortars E","methodology":"Konsystencja świeżej zaprawy metodą stolika rozpływu","methodology_en":"Consistency of fresh mortar by the flow table method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Konsystencja świeżej zaprawy metodą stolika rozpływu","reference":"PN-EN 1015-3","norm_bases":["PN-EN 1015-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tynki i zaprawy E Konsystencja świeżej zaprawy metodą stolika rozpływu PN-EN 1015-3 Tynki i zaprawy E Konsystencja swiezej zaprawy metoda stolika rozplywu PN-EN 1015-3","categories":["other"],"row_index":989,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plasters and mortars E Consistency of fresh mortar by the flow table method PN-EN 1015-3","search_zh":"抹面砂浆与砌筑砂浆 E PN-EN 1015-3","test_object_zh":"抹面砂浆与砌筑砂浆 E"},{"_id":"6a5a55f19af9f73f382512f2","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Tynki i zaprawy E","test_object_en":"Plasters and mortars E","methodology":"Przyczepność do podłoża stwardniałych zapraw na obrzutkę i do tynkowania Zakres: do 16 kN","methodology_en":"Adhesion to the substrate of hardened rendering and plastering mortars Range: up to 16 kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przyczepność do podłoża stwardniałych zapraw na obrzutkę i do tynkowania Zakres: do 16 kN","reference":"PN-EN 1015-12","norm_bases":["PN-EN 1015-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tynki i zaprawy E Przyczepność do podłoża stwardniałych zapraw na obrzutkę i do tynkowania Zakres: do 16 kN PN-EN 1015-12 Tynki i zaprawy E Przyczepnosc do podloza stwardnialych zapraw na obrzutke i do tynkowania Zakres: do 16 kN PN-EN 1015-12","categories":["other"],"row_index":990,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plasters and mortars E Adhesion to the substrate of hardened rendering and plastering mortars Range: up to 16 kN PN-EN 1015-12","search_zh":"抹面砂浆与砌筑砂浆 E PN-EN 1015-12","test_object_zh":"抹面砂浆与砌筑砂浆 E"},{"_id":"6a5a55f19af9f73f382512f3","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Tynki i zaprawy E","test_object_en":"Plasters and mortars E","methodology":"Współczynnik absorpcji spowodowanej podciąganiem kapilarnym stwardniałej zaprawy","methodology_en":"Coefficient of water absorption due to capillary action of hardened mortar","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Współczynnik absorpcji spowodowanej podciąganiem kapilarnym stwardniałej zaprawy","reference":"PN-EN 1015-18","norm_bases":["PN-EN 1015-18"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tynki i zaprawy E Współczynnik absorpcji spowodowanej podciąganiem kapilarnym stwardniałej zaprawy PN-EN 1015-18 Tynki i zaprawy E Wspolczynnik absorpcji spowodowanej podciaganiem kapilarnym stwardnialej zaprawy PN-EN 1015-18","categories":["other"],"row_index":991,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plasters and mortars E Coefficient of water absorption due to capillary action of hardened mortar PN-EN 1015-18","search_zh":"抹面砂浆与砌筑砂浆 E PN-EN 1015-18","test_object_zh":"抹面砂浆与砌筑砂浆 E"},{"_id":"6a5a55f19af9f73f382512f4","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Tynki i zaprawy E","test_object_en":"Plasters and mortars E","methodology":"Wytrzymałość na zginanie i ściskanie Oprócz zapraw z wapna powietrznego i zapraw z wapna powietrznego i cementu o masie cementu nie przekraczającej 50% całkowitej masy spoiwa. Zakres: do 10 kN","methodology_en":"Flexural and compressive strength Except for air lime mortars and air lime and cement mortars in which the mass of cement does not exceed 50% of the total mass of the binder. Range: up to 10 kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na zginanie i ściskanie Oprócz zapraw z wapna powietrznego i zapraw z wapna powietrznego i cementu o masie cementu nie przekraczającej 50% całkowitej masy spoiwa. Zakres: do 10 kN","reference":"EAD 350140-00-1106 PN-EN 1015-11","norm_bases":["EAD 350140-00-1106 PN-EN 1015-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tynki i zaprawy E Wytrzymałość na zginanie i ściskanie Oprócz zapraw z wapna powietrznego i zapraw z wapna powietrznego i cementu o masie cementu nie przekraczającej 50% całkowitej masy spoiwa. Zakres: do 10 kN EAD 350140-00-1106 PN-EN 1015-11 Tynki i zaprawy E Wytrzymalosc na zginanie i sciskanie Oprocz zapraw z wapna powietrznego i zapraw z wapna powietrznego i cementu o masie cementu nie przekraczajacej 50% calkowitej masy spoiwa. Zakres: do 10 kN EAD 350140-00-1106 PN-EN 1015-11","categories":["construction"],"row_index":992,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plasters and mortars E Flexural and compressive strength Except for air lime mortars and air lime and cement mortars in which the mass of cement does not exceed 50% of the total mass of the binder. Range: up to 10 kN EAD 350140-00-1106 PN-EN 1015-11","search_zh":"抹面砂浆与砌筑砂浆 E EAD 350140-00-1106 PN-EN 1015-11","test_object_zh":"抹面砂浆与砌筑砂浆 E"},{"_id":"6a5a55f19af9f73f382512f5","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kleje, wyroby z połączeniami klejowymi E","test_object_en":"Adhesives, products with adhesive joints E","methodology":"Wytrzymałość spoiny klejowej na rozciąganie","methodology_en":"Tensile strength of the adhesive joint","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość spoiny klejowej na rozciąganie","reference":"EAD 040083-XX-0404","norm_bases":["EAD 040083-XX-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kleje, wyroby z połączeniami klejowymi E Wytrzymałość spoiny klejowej na rozciąganie EAD 040083-XX-0404 Kleje, wyroby z polaczeniami klejowymi E Wytrzymalosc spoiny klejowej na rozciaganie EAD 040083-XX-0404","categories":["other"],"row_index":993,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Adhesives, products with adhesive joints E Tensile strength of the adhesive joint EAD 040083-XX-0404","search_zh":"胶粘剂、含胶接接头的制品 E EAD 040083-XX-0404","test_object_zh":"胶粘剂、含胶接接头的制品 E"},{"_id":"6a5a55f19af9f73f382512f6","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kleje, wyroby z połączeniami klejowymi E","test_object_en":"Adhesives, products with adhesive joints E","methodology":"Wytrzymałość spoiny klejowej na rozciąganie przy modyfikacji warunków klejenia, tj. grubości, czasu otwartego, temperatury aplikacji","methodology_en":"Tensile strength of the adhesive joint with modified bonding conditions, i.e. thickness, open time, application temperature","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość spoiny klejowej na rozciąganie przy modyfikacji warunków klejenia, tj. grubości, czasu otwartego, temperatury aplikacji","reference":"EAD 040083-XX-0404","norm_bases":["EAD 040083-XX-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kleje, wyroby z połączeniami klejowymi E Wytrzymałość spoiny klejowej na rozciąganie przy modyfikacji warunków klejenia, tj. grubości, czasu otwartego, temperatury aplikacji EAD 040083-XX-0404 Kleje, wyroby z polaczeniami klejowymi E Wytrzymalosc spoiny klejowej na rozciaganie przy modyfikacji warunkow klejenia, tj. grubosci, czasu otwartego, temperatury aplikacji EAD 040083-XX-0404","categories":["other"],"row_index":994,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Adhesives, products with adhesive joints E Tensile strength of the adhesive joint with modified bonding conditions, i.e. thickness, open time, application temperature EAD 040083-XX-0404","search_zh":"胶粘剂、含胶接接头的制品 E EAD 040083-XX-0404","test_object_zh":"胶粘剂、含胶接接头的制品 E"},{"_id":"6a5a55f19af9f73f382512f7","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kleje, wyroby z połączeniami klejowymi E","test_object_en":"Adhesives, products with adhesive joints E","methodology":"Wytrzymałość na ścinanie i moduł sprężystości poprzecznej","methodology_en":"Shear strength and shear modulus","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ścinanie i moduł sprężystości poprzecznej","reference":"EAD 040083-XX-0404","norm_bases":["EAD 040083-XX-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kleje, wyroby z połączeniami klejowymi E Wytrzymałość na ścinanie i moduł sprężystości poprzecznej EAD 040083-XX-0404 Kleje, wyroby z polaczeniami klejowymi E Wytrzymalosc na scinanie i modul sprezystosci poprzecznej EAD 040083-XX-0404","categories":["other"],"row_index":995,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Adhesives, products with adhesive joints E Shear strength and shear modulus EAD 040083-XX-0404","search_zh":"胶粘剂、含胶接接头的制品 E EAD 040083-XX-0404","test_object_zh":"胶粘剂、含胶接接头的制品 E"},{"_id":"6a5a55f19af9f73f382512f8","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty płaskie włóknisto- cementowe, magnezowe i inne na spoiwach mineralnych E","test_object_en":"Flat fibre-cement, magnesium and other mineral-bonded boards E","methodology":"Gęstość pozorna","methodology_en":"Apparent density","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Gęstość pozorna","reference":"PN-EN 12467","norm_bases":["PN-EN 12467"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty płaskie włóknisto- cementowe, magnezowe i inne na spoiwach mineralnych E Gęstość pozorna PN-EN 12467 Plyty plaskie wloknisto- cementowe, magnezowe i inne na spoiwach mineralnych E Gestosc pozorna PN-EN 12467","categories":["construction"],"row_index":996,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Flat fibre-cement, magnesium and other mineral-bonded boards E Apparent density PN-EN 12467","methodology_zh":"表观密度","search_zh":"纤维水泥平板、镁质板及其他矿物胶结平板 E 表观密度 PN-EN 12467","test_object_zh":"纤维水泥平板、镁质板及其他矿物胶结平板 E"},{"_id":"6a5a55f19af9f73f382512f9","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty płaskie włóknisto- cementowe, magnezowe i inne na spoiwach mineralnych E","test_object_en":"Flat fibre-cement, magnesium and other mineral-bonded boards E","methodology":"Wytrzymałość na zginanie Zakres: do 30 kN Metoda wytrzymałościowa","methodology_en":"Flexural strength Range: up to 30 kN Strength method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na zginanie Zakres: do 30 kN Metoda wytrzymałościowa","reference":"PN-EN 12467","norm_bases":["PN-EN 12467"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty płaskie włóknisto- cementowe, magnezowe i inne na spoiwach mineralnych E Wytrzymałość na zginanie Zakres: do 30 kN Metoda wytrzymałościowa PN-EN 12467 Plyty plaskie wloknisto- cementowe, magnezowe i inne na spoiwach mineralnych E Wytrzymalosc na zginanie Zakres: do 30 kN Metoda wytrzymalosciowa PN-EN 12467","categories":["construction"],"row_index":997,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Flat fibre-cement, magnesium and other mineral-bonded boards E Flexural strength Range: up to 30 kN Strength method PN-EN 12467","search_zh":"纤维水泥平板、镁质板及其他矿物胶结平板 E PN-EN 12467","test_object_zh":"纤维水泥平板、镁质板及其他矿物胶结平板 E"},{"_id":"6a5a55f19af9f73f382512fa","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty płaskie włóknisto- cementowe, magnezowe i inne na spoiwach mineralnych E","test_object_en":"Flat fibre-cement, magnesium and other mineral-bonded boards E","methodology":"Zamrażanie-rozmrażanie","methodology_en":"Freeze-thaw","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zamrażanie-rozmrażanie","reference":"PN-EN 12467","norm_bases":["PN-EN 12467"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty płaskie włóknisto- cementowe, magnezowe i inne na spoiwach mineralnych E Zamrażanie-rozmrażanie PN-EN 12467 Plyty plaskie wloknisto- cementowe, magnezowe i inne na spoiwach mineralnych E Zamrazanie-rozmrazanie PN-EN 12467","categories":["construction"],"row_index":998,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Flat fibre-cement, magnesium and other mineral-bonded boards E Freeze-thaw PN-EN 12467","search_zh":"纤维水泥平板、镁质板及其他矿物胶结平板 E PN-EN 12467","test_object_zh":"纤维水泥平板、镁质板及其他矿物胶结平板 E"},{"_id":"6a5a55f19af9f73f382512fb","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty płaskie włóknisto- cementowe, magnezowe i inne na spoiwach mineralnych E","test_object_en":"Flat fibre-cement, magnesium and other mineral-bonded boards E","methodology":"Odporność na ciepłą wodę","methodology_en":"Resistance to hot water","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na ciepłą wodę","reference":"PN-EN 12467","norm_bases":["PN-EN 12467"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty płaskie włóknisto- cementowe, magnezowe i inne na spoiwach mineralnych E Odporność na ciepłą wodę PN-EN 12467 Plyty plaskie wloknisto- cementowe, magnezowe i inne na spoiwach mineralnych E Odpornosc na ciepla wode PN-EN 12467","categories":["construction"],"row_index":999,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Flat fibre-cement, magnesium and other mineral-bonded boards E Resistance to hot water PN-EN 12467","search_zh":"纤维水泥平板、镁质板及其他矿物胶结平板 E PN-EN 12467","test_object_zh":"纤维水泥平板、镁质板及其他矿物胶结平板 E"},{"_id":"6a5a55f19af9f73f382512fc","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty płaskie włóknisto- cementowe, magnezowe i inne na spoiwach mineralnych E","test_object_en":"Flat fibre-cement, magnesium and other mineral-bonded boards E","methodology":"Odporność na grzanie-deszczowanie","methodology_en":"Resistance to heating-water spraying","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na grzanie-deszczowanie","reference":"PN-EN 12467","norm_bases":["PN-EN 12467"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty płaskie włóknisto- cementowe, magnezowe i inne na spoiwach mineralnych E Odporność na grzanie-deszczowanie PN-EN 12467 Plyty plaskie wloknisto- cementowe, magnezowe i inne na spoiwach mineralnych E Odpornosc na grzanie-deszczowanie PN-EN 12467","categories":["construction"],"row_index":1000,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Flat fibre-cement, magnesium and other mineral-bonded boards E Resistance to heating-water spraying PN-EN 12467","search_zh":"纤维水泥平板、镁质板及其他矿物胶结平板 E PN-EN 12467","test_object_zh":"纤维水泥平板、镁质板及其他矿物胶结平板 E"},{"_id":"6a5a55f19af9f73f382512fd","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty płaskie włóknisto- cementowe, magnezowe i inne na spoiwach mineralnych E","test_object_en":"Flat fibre-cement, magnesium and other mineral-bonded boards E","methodology":"Odporność na kąpiel-suszenie","methodology_en":"Resistance to immersion-drying","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na kąpiel-suszenie","reference":"PN-EN 12467","norm_bases":["PN-EN 12467"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty płaskie włóknisto- cementowe, magnezowe i inne na spoiwach mineralnych E Odporność na kąpiel-suszenie PN-EN 12467 Plyty plaskie wloknisto- cementowe, magnezowe i inne na spoiwach mineralnych E Odpornosc na kapiel-suszenie PN-EN 12467","categories":["construction"],"row_index":1001,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Flat fibre-cement, magnesium and other mineral-bonded boards E Resistance to immersion-drying PN-EN 12467","search_zh":"纤维水泥平板、镁质板及其他矿物胶结平板 E PN-EN 12467","test_object_zh":"纤维水泥平板、镁质板及其他矿物胶结平板 E"},{"_id":"6a5a55f19af9f73f382512fe","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Czynnik starzenia materiału zbiornika","methodology_en":"Ageing factor of the tank material","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Czynnik starzenia materiału zbiornika","reference":"PN-EN 12566-3 „N”","norm_bases":["PN-EN 12566-3 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Czynnik starzenia materiału zbiornika PN-EN 12566-3 „N” Wyroby z tworzyw sztucznych E Czynnik starzenia materialu zbiornika PN-EN 12566-3 „N”","categories":["materials"],"row_index":1002,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Ageing factor of the tank material PN-EN 12566-3 „N”","search_zh":"塑料制品 E PN-EN 12566-3 „N”","test_object_zh":"塑料制品 E"},{"_id":"6a5a55f19af9f73f382512ff","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Współczynnik pełzania materiału zbiornika","methodology_en":"Creep coefficient of the tank material","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Współczynnik pełzania materiału zbiornika","reference":"PN-EN 12566-3 „N”","norm_bases":["PN-EN 12566-3 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Współczynnik pełzania materiału zbiornika PN-EN 12566-3 „N” Wyroby z tworzyw sztucznych E Wspolczynnik pelzania materialu zbiornika PN-EN 12566-3 „N”","categories":["materials"],"row_index":1003,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Creep coefficient of the tank material PN-EN 12566-3 „N”","search_zh":"塑料制品 E PN-EN 12566-3 „N”","test_object_zh":"塑料制品 E"},{"_id":"6a5a55f19af9f73f38251300","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty gipsowo-kartonowe E","test_object_en":"Gypsum plasterboards E","methodology":"Wytrzymałość na ścinanie Zakres: (20 - 50000) N Metoda ścinania","methodology_en":"Shear strength Range: (20 - 50000) N Shear method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ścinanie Zakres: (20 - 50000) N Metoda ścinania","reference":"PN-EN 520 „N”","norm_bases":["PN-EN 520 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty gipsowo-kartonowe E Wytrzymałość na ścinanie Zakres: (20 - 50000) N Metoda ścinania PN-EN 520 „N” Plyty gipsowo-kartonowe E Wytrzymalosc na scinanie Zakres: (20 - 50000) N Metoda scinania PN-EN 520 „N”","categories":["other"],"row_index":1004,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gypsum plasterboards E Shear strength Range: (20 - 50000) N Shear method PN-EN 520 „N”"},{"_id":"6a5a55f19af9f73f38251301","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Powłoki E","test_object_en":"Coatings E","methodology":"Cykle przyspieszonego starzenia Metoda ekspozycji w UV, met. A","methodology_en":"Accelerated ageing cycles UV exposure method, met. A","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cykle przyspieszonego starzenia Metoda ekspozycji w UV, met. A","reference":"PN-EN ISO 4892-2","norm_bases":["PN-EN ISO 4892-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki E Cykle przyspieszonego starzenia Metoda ekspozycji w UV, met. A PN-EN ISO 4892-2 Powloki E Cykle przyspieszonego starzenia Metoda ekspozycji w UV, met. A PN-EN ISO 4892-2","categories":["other"],"row_index":1005,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coatings E Accelerated ageing cycles UV exposure method, met. A PN-EN ISO 4892-2","search_zh":"涂层 E PN-EN ISO 4892-2","test_object_zh":"涂层 E"},{"_id":"6a5a55f19af9f73f38251302","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Powłoki E","test_object_en":"Coatings E","methodology":"Cykle przyspieszonego starzenia Metoda ekspozycji w UV, met. B","methodology_en":"Accelerated ageing cycles UV exposure method, met. B","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cykle przyspieszonego starzenia Metoda ekspozycji w UV, met. B","reference":"PN-EN ISO 4892-2","norm_bases":["PN-EN ISO 4892-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki E Cykle przyspieszonego starzenia Metoda ekspozycji w UV, met. B PN-EN ISO 4892-2 Powloki E Cykle przyspieszonego starzenia Metoda ekspozycji w UV, met. B PN-EN ISO 4892-2","categories":["other"],"row_index":1006,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coatings E Accelerated ageing cycles UV exposure method, met. B PN-EN ISO 4892-2","search_zh":"涂层 E PN-EN ISO 4892-2","test_object_zh":"涂层 E"},{"_id":"6a5a55f19af9f73f38251303","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Powłoki E","test_object_en":"Coatings E","methodology":"Cykle przyspieszonego starzenia Metoda ekspozycji w UV","methodology_en":"Accelerated ageing cycles UV exposure method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cykle przyspieszonego starzenia Metoda ekspozycji w UV","reference":"PN-EN ISO 4892-3","norm_bases":["PN-EN ISO 4892-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki E Cykle przyspieszonego starzenia Metoda ekspozycji w UV PN-EN ISO 4892-3 Powloki E Cykle przyspieszonego starzenia Metoda ekspozycji w UV PN-EN ISO 4892-3","categories":["other"],"row_index":1007,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coatings E Accelerated ageing cycles UV exposure method PN-EN ISO 4892-3","search_zh":"涂层 E PN-EN ISO 4892-3","test_object_zh":"涂层 E"},{"_id":"6a5a55f19af9f73f38251304","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Powłoki E","test_object_en":"Coatings E","methodology":"Odporność na ścieranie Metoda: Tabera","methodology_en":"Abrasion resistance Method: Taber","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na ścieranie Metoda: Tabera","reference":"PN-EN ISO 5470-1","norm_bases":["PN-EN ISO 5470-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki E Odporność na ścieranie Metoda: Tabera PN-EN ISO 5470-1 Powloki E Odpornosc na scieranie Metoda: Tabera PN-EN ISO 5470-1","categories":["other"],"row_index":1008,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coatings E Abrasion resistance Method: Taber PN-EN ISO 5470-1","search_zh":"涂层 E PN-EN ISO 5470-1","test_object_zh":"涂层 E"},{"_id":"6a5a55f19af9f73f38251305","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Powłoki E","test_object_en":"Coatings E","methodology":"Odporność na działanie atmosferyczne I sztuczne promieniowanie Metoda ekspozycji w UV Natężenie promieniowania Zakres: (0,1 -1,1) W/m2","methodology_en":"Resistance to weathering and artificial radiation UV exposure method Irradiance Range: (0,1 -1,1) W/m2","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie atmosferyczne I sztuczne promieniowanie Metoda ekspozycji w UV Natężenie promieniowania Zakres: (0,1 -1,1) W/m2","reference":"PN-EN ISO 16474-3","norm_bases":["PN-EN ISO 16474-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki E Odporność na działanie atmosferyczne I sztuczne promieniowanie Metoda ekspozycji w UV Natężenie promieniowania Zakres: (0,1 -1,1) W/m2 PN-EN ISO 16474-3 Powloki E Odpornosc na dzialanie atmosferyczne I sztuczne promieniowanie Metoda ekspozycji w UV Natezenie promieniowania Zakres: (0,1 -1,1) W/m2 PN-EN ISO 16474-3","categories":["other"],"row_index":1009,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coatings E Resistance to weathering and artificial radiation UV exposure method Irradiance Range: (0,1 -1,1) W/m2 PN-EN ISO 16474-3","search_zh":"涂层 E PN-EN ISO 16474-3","test_object_zh":"涂层 E"},{"_id":"6a5a55f19af9f73f38251306","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Powłoki E","test_object_en":"Coatings E","methodology":"Połysk w geometrii 20, 60, 85 stopni Metoda fotometryczna Także in situ","methodology_en":"Gloss at 20, 60, 85 degree geometry Photometric method Also in situ","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Połysk w geometrii 20, 60, 85 stopni Metoda fotometryczna Także in situ","reference":"PN-EN ISO 2813 „N”","norm_bases":["PN-EN ISO 2813 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki E Połysk w geometrii 20, 60, 85 stopni Metoda fotometryczna Także in situ PN-EN ISO 2813 „N” Powloki E Polysk w geometrii 20, 60, 85 stopni Metoda fotometryczna Takze in situ PN-EN ISO 2813 „N”","categories":["other"],"row_index":1010,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coatings E Gloss at 20, 60, 85 degree geometry Photometric method Also in situ PN-EN ISO 2813 „N”","search_zh":"涂层 E PN-EN ISO 2813 „N”","test_object_zh":"涂层 E"},{"_id":"6a5a55f19af9f73f38251307","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Powłoki E","test_object_en":"Coatings E","methodology":"Przyczepność Metoda siatki nacięć także in situ","methodology_en":"Adhesion Cross-cut method also in situ","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przyczepność Metoda siatki nacięć także in situ","reference":"PN-EN ISO 2409","norm_bases":["PN-EN ISO 2409"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki E Przyczepność Metoda siatki nacięć także in situ PN-EN ISO 2409 Powloki E Przyczepnosc Metoda siatki naciec takze in situ PN-EN ISO 2409","categories":["other"],"row_index":1011,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coatings E Adhesion Cross-cut method also in situ PN-EN ISO 2409","search_zh":"涂层 E PN-EN ISO 2409","test_object_zh":"涂层 E"},{"_id":"6a5a55f19af9f73f38251308","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Powłoki E","test_object_en":"Coatings E","methodology":"Spęcherzenie także in situ","methodology_en":"Blistering also in situ","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Spęcherzenie także in situ","reference":"PN-EN ISO 4628-2","norm_bases":["PN-EN ISO 4628-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki E Spęcherzenie także in situ PN-EN ISO 4628-2 Powloki E Specherzenie takze in situ PN-EN ISO 4628-2","categories":["other"],"row_index":1012,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coatings E Blistering also in situ PN-EN ISO 4628-2","search_zh":"涂层 E PN-EN ISO 4628-2","test_object_zh":"涂层 E"},{"_id":"6a5a55f19af9f73f38251309","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Powłoki E","test_object_en":"Coatings E","methodology":"Spękanie także in situ","methodology_en":"Cracking also in situ","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Spękanie także in situ","reference":"PN-EN ISO 4628-4","norm_bases":["PN-EN ISO 4628-4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki E Spękanie także in situ PN-EN ISO 4628-4 Powloki E Spekanie takze in situ PN-EN ISO 4628-4","categories":["other"],"row_index":1013,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coatings E Cracking also in situ PN-EN ISO 4628-4","search_zh":"涂层 E PN-EN ISO 4628-4","test_object_zh":"涂层 E"},{"_id":"6a5a55f19af9f73f3825130a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Powłoki E","test_object_en":"Coatings E","methodology":"Złuszczenie także in situ","methodology_en":"Flaking also in situ","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Złuszczenie także in situ","reference":"PN-EN ISO 4628-5","norm_bases":["PN-EN ISO 4628-5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki E Złuszczenie także in situ PN-EN ISO 4628-5 Powloki E Zluszczenie takze in situ PN-EN ISO 4628-5","categories":["other"],"row_index":1014,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coatings E Flaking also in situ PN-EN ISO 4628-5","search_zh":"涂层 E PN-EN ISO 4628-5","test_object_zh":"涂层 E"},{"_id":"6a5a55f19af9f73f3825130b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Powłoki E","test_object_en":"Coatings E","methodology":"Kredowanie Metoda wizualna, metoda taśmy także in situ","methodology_en":"Chalking Visual method, tape method, also in situ","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Kredowanie Metoda wizualna, metoda taśmy także in situ","reference":"PN-EN ISO 4628-6","norm_bases":["PN-EN ISO 4628-6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki E Kredowanie Metoda wizualna, metoda taśmy także in situ PN-EN ISO 4628-6 Powloki E Kredowanie Metoda wizualna, metoda tasmy takze in situ PN-EN ISO 4628-6","categories":["other"],"row_index":1015,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coatings E Chalking Visual method, tape method, also in situ PN-EN ISO 4628-6","search_zh":"涂层 E PN-EN ISO 4628-6","test_object_zh":"涂层 E"},{"_id":"6a5a55f19af9f73f3825130c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Powłoki E","test_object_en":"Coatings E","methodology":"Barwa, różnica barwy, metameryzm Metoda kalorymetryczna Metoda spektrofotometru także in situ","methodology_en":"Colour, colour difference, metamerism Colorimetric method Spectrophotometric method, also in situ","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Barwa, różnica barwy, metameryzm Metoda kalorymetryczna Metoda spektrofotometru także in situ","reference":"PN-EN ISO 7724-2","norm_bases":["PN-EN ISO 7724-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki E Barwa, różnica barwy, metameryzm Metoda kalorymetryczna Metoda spektrofotometru także in situ PN-EN ISO 7724-2 Powloki E Barwa, roznica barwy, metameryzm Metoda kalorymetryczna Metoda spektrofotometru takze in situ PN-EN ISO 7724-2","categories":["other"],"row_index":1016,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coatings E Colour, colour difference, metamerism Colorimetric method Spectrophotometric method, also in situ PN-EN ISO 7724-2","search_zh":"涂层 E PN-EN ISO 7724-2","test_object_zh":"涂层 E"},{"_id":"6a5a55f19af9f73f3825130d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Cykle przyspieszonego starzenia Metoda ekspozycji w UV Met. A","methodology_en":"Accelerated ageing cycles UV exposure method Met. A","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cykle przyspieszonego starzenia Metoda ekspozycji w UV Met. A","reference":"PN-EN ISO 4892-2 „N”","norm_bases":["PN-EN ISO 4892-2 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Cykle przyspieszonego starzenia Metoda ekspozycji w UV Met. A PN-EN ISO 4892-2 „N” Wyroby z tworzyw sztucznych E Cykle przyspieszonego starzenia Metoda ekspozycji w UV Met. A PN-EN ISO 4892-2 „N”","categories":["other"],"row_index":1017,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Accelerated ageing cycles UV exposure method Met. A PN-EN ISO 4892-2 „N”","search_zh":"塑料制品 E PN-EN ISO 4892-2 „N”","test_object_zh":"塑料制品 E"},{"_id":"6a5a55f19af9f73f3825130e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Cykle przyspieszonego starzenia Metoda ekspozycji w UV Met. B","methodology_en":"Accelerated ageing cycles UV exposure method Met. B","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cykle przyspieszonego starzenia Metoda ekspozycji w UV Met. B","reference":"PN-EN ISO 4892-2 „N”","norm_bases":["PN-EN ISO 4892-2 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Cykle przyspieszonego starzenia Metoda ekspozycji w UV Met. B PN-EN ISO 4892-2 „N” Wyroby z tworzyw sztucznych E Cykle przyspieszonego starzenia Metoda ekspozycji w UV Met. B PN-EN ISO 4892-2 „N”","categories":["other"],"row_index":1018,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Accelerated ageing cycles UV exposure method Met. B PN-EN ISO 4892-2 „N”","search_zh":"塑料制品 E PN-EN ISO 4892-2 „N”","test_object_zh":"塑料制品 E"},{"_id":"6a5a55f19af9f73f3825130f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Cykle przyspieszonego starzenia Metoda ekspozycji w UV","methodology_en":"Accelerated ageing cycles UV exposure method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cykle przyspieszonego starzenia Metoda ekspozycji w UV","reference":"PN-EN ISO 4892-3","norm_bases":["PN-EN ISO 4892-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Cykle przyspieszonego starzenia Metoda ekspozycji w UV PN-EN ISO 4892-3 Wyroby z tworzyw sztucznych E Cykle przyspieszonego starzenia Metoda ekspozycji w UV PN-EN ISO 4892-3","categories":["other"],"row_index":1019,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Accelerated ageing cycles UV exposure method PN-EN ISO 4892-3","search_zh":"塑料制品 E PN-EN ISO 4892-3","test_object_zh":"塑料制品 E"},{"_id":"6a5a55f19af9f73f38251310","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Gęstość Metoda A","methodology_en":"Density Method A","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Gęstość Metoda A","reference":"PN-EN ISO 1183-1 „N”","norm_bases":["PN-EN ISO 1183-1 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Gęstość Metoda A PN-EN ISO 1183-1 „N” Wyroby z tworzyw sztucznych E Gestosc Metoda A PN-EN ISO 1183-1 „N”","categories":["other"],"row_index":1020,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Density Method A PN-EN ISO 1183-1 „N”","search_zh":"塑料制品 E PN-EN ISO 1183-1 „N”","test_object_zh":"塑料制品 E"},{"_id":"6a5a55f19af9f73f38251311","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Masowy wskaźnik szybkości płynięcia (MFR) Metoda A","methodology_en":"Melt mass-flow rate (MFR) Method A","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Masowy wskaźnik szybkości płynięcia (MFR) Metoda A","reference":"PN-EN ISO 1133 „N” PN-EN ISO 1133-1","norm_bases":["PN-EN ISO 1133 „N” PN-EN ISO 1133-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Masowy wskaźnik szybkości płynięcia (MFR) Metoda A PN-EN ISO 1133 „N” PN-EN ISO 1133-1 Wyroby z tworzyw sztucznych E Masowy wskaznik szybkosci plyniecia (MFR) Metoda A PN-EN ISO 1133 „N” PN-EN ISO 1133-1","categories":["other"],"row_index":1021,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Melt mass-flow rate (MFR) Method A PN-EN ISO 1133 „N” PN-EN ISO 1133-1","search_zh":"塑料制品 E PN-EN ISO 1133 „N” PN-EN ISO 1133-1","test_object_zh":"塑料制品 E"},{"_id":"6a5a55f19af9f73f38251312","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Moduł sprężystości przy zginaniu Zakres: do 50 kN Metoda A","methodology_en":"Modulus of elasticity in bending Range: up to 50 kN Method A","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moduł sprężystości przy zginaniu Zakres: do 50 kN Metoda A","reference":"PN-EN ISO 14125 „N”","norm_bases":["PN-EN ISO 14125 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Moduł sprężystości przy zginaniu Zakres: do 50 kN Metoda A PN-EN ISO 14125 „N” Wyroby z tworzyw sztucznych E Modul sprezystosci przy zginaniu Zakres: do 50 kN Metoda A PN-EN ISO 14125 „N”","categories":["other"],"row_index":1022,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Modulus of elasticity in bending Range: up to 50 kN Method A PN-EN ISO 14125 „N”","search_zh":"塑料制品 E PN-EN ISO 14125 „N”","test_object_zh":"塑料制品 E"},{"_id":"6a5a55f19af9f73f38251313","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Moduł sprężystości przy zginaniu Metoda A","methodology_en":"Modulus of elasticity in bending Method A","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moduł sprężystości przy zginaniu Metoda A","reference":"PN-EN 15534-1","norm_bases":["PN-EN 15534-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Moduł sprężystości przy zginaniu Metoda A PN-EN 15534-1 Wyroby z tworzyw sztucznych E Modul sprezystosci przy zginaniu Metoda A PN-EN 15534-1","categories":["other"],"row_index":1023,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Modulus of elasticity in bending Method A PN-EN 15534-1","search_zh":"塑料制品 E PN-EN 15534-1","test_object_zh":"塑料制品 E"},{"_id":"6a5a55f19af9f73f38251314","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Moduł sprężystości przy długotrwałym zginaniu","methodology_en":"Modulus of elasticity in long-term bending","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moduł sprężystości przy długotrwałym zginaniu","reference":"PN-EN ISO 9967 „N”","norm_bases":["PN-EN ISO 9967 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Moduł sprężystości przy długotrwałym zginaniu PN-EN ISO 9967 „N” Wyroby z tworzyw sztucznych E Modul sprezystosci przy dlugotrwalym zginaniu PN-EN ISO 9967 „N”","categories":["other"],"row_index":1024,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Modulus of elasticity in long-term bending PN-EN ISO 9967 „N”","search_zh":"塑料制品 E PN-EN ISO 9967 „N”","test_object_zh":"塑料制品 E"},{"_id":"6a5a55f19af9f73f38251315","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Moduł ściskania","methodology_en":"Compression modulus","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moduł ściskania","reference":"PN-EN ISO 604","norm_bases":["PN-EN ISO 604"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Moduł ściskania PN-EN ISO 604 Wyroby z tworzyw sztucznych E Modul sciskania PN-EN ISO 604","categories":["other"],"row_index":1025,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Compression modulus PN-EN ISO 604","search_zh":"塑料制品 E PN-EN ISO 604","test_object_zh":"塑料制品 E"},{"_id":"6a5a55f19af9f73f38251316","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Naprężenia ściskające przy odkształceniu X%","methodology_en":"Compressive stress at X% strain","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Naprężenia ściskające przy odkształceniu X%","reference":"PN-EN ISO 604","norm_bases":["PN-EN ISO 604"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Naprężenia ściskające przy odkształceniu X% PN-EN ISO 604 Wyroby z tworzyw sztucznych E Naprezenia sciskajace przy odksztalceniu X% PN-EN ISO 604","categories":["other"],"row_index":1026,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Compressive stress at X% strain PN-EN ISO 604","search_zh":"塑料制品 E PN-EN ISO 604","test_object_zh":"塑料制品 E"},{"_id":"6a5a55f19af9f73f38251317","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Odporność na działanie ciekłych substancji chemicznych, w tym wody Metoda wagowa","methodology_en":"Resistance to liquid chemicals, including water Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie ciekłych substancji chemicznych, w tym wody Metoda wagowa","reference":"PN-EN ISO 175 „N”","norm_bases":["PN-EN ISO 175 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Odporność na działanie ciekłych substancji chemicznych, w tym wody Metoda wagowa PN-EN ISO 175 „N” Wyroby z tworzyw sztucznych E Odpornosc na dzialanie cieklych substancji chemicznych, w tym wody Metoda wagowa PN-EN ISO 175 „N”","categories":["water"],"row_index":1027,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Resistance to liquid chemicals, including water Gravimetric method PN-EN ISO 175 „N”","search_zh":"塑料制品 E 耐液体化学物质（含水）作用性 重量法 PN-EN ISO 175 „N”","test_object_zh":"塑料制品 E","methodology_zh":"耐液体化学物质（含水）作用性 重量法"},{"_id":"6a5a55f19af9f73f38251318","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Odporność na działanie grzybów pleśniowych","methodology_en":"Resistance to mould fungi","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie grzybów pleśniowych","reference":"PN-EN ISO 846 „N”","norm_bases":["PN-EN ISO 846 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Odporność na działanie grzybów pleśniowych PN-EN ISO 846 „N” Wyroby z tworzyw sztucznych E Odpornosc na dzialanie grzybow plesniowych PN-EN ISO 846 „N”","categories":["microbiology"],"row_index":1028,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Resistance to mould fungi PN-EN ISO 846 „N”","search_zh":"塑料制品 E PN-EN ISO 846 „N”","test_object_zh":"塑料制品 E"},{"_id":"6a5a55f19af9f73f38251319","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Temperatura mięknienia wg Vicata Zakres: (0 - 90)°C metoda B50 Ciecz – czynnik grzewczy","methodology_en":"Vicat softening temperature Range: (0 - 90)°C method B50 Liquid – heating medium","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Temperatura mięknienia wg Vicata Zakres: (0 - 90)°C metoda B50 Ciecz – czynnik grzewczy","reference":"PN-EN ISO 306","norm_bases":["PN-EN ISO 306"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Temperatura mięknienia wg Vicata Zakres: (0 - 90)°C metoda B50 Ciecz – czynnik grzewczy PN-EN ISO 306 Wyroby z tworzyw sztucznych E Temperatura mieknienia wg Vicata Zakres: (0 - 90)°C metoda B50 Ciecz – czynnik grzewczy PN-EN ISO 306","categories":["other"],"row_index":1029,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Vicat softening temperature Range: (0 - 90)°C method B50 Liquid – heating medium PN-EN ISO 306","search_zh":"塑料制品 E PN-EN ISO 306","test_object_zh":"塑料制品 E"},{"_id":"6a5a55f19af9f73f3825131a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Twardość Metoda Shore’a Skala A i D","methodology_en":"Hardness Shore method Scale A and D","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Twardość Metoda Shore’a Skala A i D","reference":"PN-EN ISO 868","norm_bases":["PN-EN ISO 868"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Twardość Metoda Shore’a Skala A i D PN-EN ISO 868 Wyroby z tworzyw sztucznych E Twardosc Metoda Shore’a Skala A i D PN-EN ISO 868","categories":["other"],"row_index":1030,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Hardness Shore method Scale A and D PN-EN ISO 868","search_zh":"塑料制品 E PN-EN ISO 868","test_object_zh":"塑料制品 E"},{"_id":"6a5a55f19af9f73f3825131b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Udarność metodą Charpy’ego Zakres: młot 2J i 4J","methodology_en":"Impact strength by the Charpy method Range: 2J and 4J hammer","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Udarność metodą Charpy’ego Zakres: młot 2J i 4J","reference":"PN-EN ISO 179-1","norm_bases":["PN-EN ISO 179-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Udarność metodą Charpy’ego Zakres: młot 2J i 4J PN-EN ISO 179-1 Wyroby z tworzyw sztucznych E Udarnosc metoda Charpy’ego Zakres: mlot 2J i 4J PN-EN ISO 179-1","categories":["other"],"row_index":1031,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Impact strength by the Charpy method Range: 2J and 4J hammer PN-EN ISO 179-1","search_zh":"塑料制品 E PN-EN ISO 179-1","test_object_zh":"塑料制品 E"},{"_id":"6a5a55f19af9f73f3825131c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Wytrzymałość na zginanie Zakres: do 50 kN Metoda: A","methodology_en":"Flexural strength Range: up to 50 kN Method: A","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na zginanie Zakres: do 50 kN Metoda: A","reference":"PN-EN ISO 178","norm_bases":["PN-EN ISO 178"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Wytrzymałość na zginanie Zakres: do 50 kN Metoda: A PN-EN ISO 178 Wyroby z tworzyw sztucznych E Wytrzymalosc na zginanie Zakres: do 50 kN Metoda: A PN-EN ISO 178","categories":["other"],"row_index":1032,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Flexural strength Range: up to 50 kN Method: A PN-EN ISO 178","search_zh":"塑料制品 E PN-EN ISO 178","test_object_zh":"塑料制品 E"},{"_id":"6a5a55f19af9f73f3825131d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Wytrzymałość na zginanie","methodology_en":"Flexural strength","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na zginanie","reference":"PN-EN 15534-1","norm_bases":["PN-EN 15534-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Wytrzymałość na zginanie PN-EN 15534-1 Wyroby z tworzyw sztucznych E Wytrzymalosc na zginanie PN-EN 15534-1","categories":["other"],"row_index":1033,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Flexural strength PN-EN 15534-1","methodology_zh":"抗弯强度","search_zh":"塑料制品 E 抗弯强度 PN-EN 15534-1","test_object_zh":"塑料制品 E"},{"_id":"6a5a55f19af9f73f3825131e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Wytrzymałość na rozciąganie udarowe Zakres: młot 25J i 50J","methodology_en":"Impact tensile strength Range: hammer 25J and 50J","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na rozciąganie udarowe Zakres: młot 25J i 50J","reference":"PN-EN ISO 8256 „N”","norm_bases":["PN-EN ISO 8256 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Wytrzymałość na rozciąganie udarowe Zakres: młot 25J i 50J PN-EN ISO 8256 „N” Wyroby z tworzyw sztucznych E Wytrzymalosc na rozciaganie udarowe Zakres: mlot 25J i 50J PN-EN ISO 8256 „N”","categories":["other"],"row_index":1034,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Impact tensile strength Range: hammer 25J and 50J PN-EN ISO 8256 „N”","search_zh":"塑料制品 E PN-EN ISO 8256 „N”","test_object_zh":"塑料制品 E"},{"_id":"6a5a55f19af9f73f3825131f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Wytrzymałość na ściskanie","methodology_en":"Compressive strength","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie","reference":"PN-EN ISO 604","norm_bases":["PN-EN ISO 604"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Wytrzymałość na ściskanie PN-EN ISO 604 Wyroby z tworzyw sztucznych E Wytrzymalosc na sciskanie PN-EN ISO 604","categories":["other"],"row_index":1035,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Compressive strength PN-EN ISO 604","methodology_zh":"抗压强度","search_zh":"塑料制品 E 抗压强度 PN-EN ISO 604","test_object_zh":"塑料制品 E"},{"_id":"6a5a55f19af9f73f38251320","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Odporność na uderzenie","methodology_en":"Impact resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie","reference":"PN-EN 15534-1","norm_bases":["PN-EN 15534-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Odporność na uderzenie PN-EN 15534-1 Wyroby z tworzyw sztucznych E Odpornosc na uderzenie PN-EN 15534-1","categories":["other"],"row_index":1036,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Impact resistance PN-EN 15534-1","search_zh":"塑料制品 E 耐冲击性 PN-EN 15534-1","test_object_zh":"塑料制品 E","methodology_zh":"耐冲击性"},{"_id":"6a5a55f19af9f73f38251321","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Odporność na zawilgocenie po oddziaływaniach cyklicznych","methodology_en":"Resistance to moisture uptake after cyclic exposure","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zawilgocenie po oddziaływaniach cyklicznych","reference":"PN-EN 15534-1","norm_bases":["PN-EN 15534-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Odporność na zawilgocenie po oddziaływaniach cyklicznych PN-EN 15534-1 Wyroby z tworzyw sztucznych E Odpornosc na zawilgocenie po oddzialywaniach cyklicznych PN-EN 15534-1","categories":["other"],"row_index":1037,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Resistance to moisture uptake after cyclic exposure PN-EN 15534-1","search_zh":"塑料制品 E PN-EN 15534-1","test_object_zh":"塑料制品 E"},{"_id":"6a5a55f19af9f73f38251322","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Spęcznienie i nasiąkliwość","methodology_en":"Swelling and water absorption","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Spęcznienie i nasiąkliwość","reference":"PN-EN 15534-1","norm_bases":["PN-EN 15534-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Spęcznienie i nasiąkliwość PN-EN 15534-1 Wyroby z tworzyw sztucznych E Specznienie i nasiakliwosc PN-EN 15534-1","categories":["other"],"row_index":1038,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Swelling and water absorption PN-EN 15534-1","search_zh":"塑料制品 E PN-EN 15534-1","test_object_zh":"塑料制品 E"},{"_id":"6a5a55f19af9f73f38251323","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Odkształcenie trwałe po ściskaniu Metoda: A, B, C","methodology_en":"Compression set Method: A, B, C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odkształcenie trwałe po ściskaniu Metoda: A, B, C","reference":"PN-EN ISO 1856","norm_bases":["PN-EN ISO 1856"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Odkształcenie trwałe po ściskaniu Metoda: A, B, C PN-EN ISO 1856 Wyroby z tworzyw sztucznych E Odksztalcenie trwale po sciskaniu Metoda: A, B, C PN-EN ISO 1856","categories":["other"],"row_index":1039,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Compression set Method: A, B, C PN-EN ISO 1856","search_zh":"塑料制品 E PN-EN ISO 1856","test_object_zh":"塑料制品 E"},{"_id":"6a5a55f19af9f73f38251324","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Moduł sprężystości poprzecznej (układ z pojedynczą próbką) Zakres: (20 - 50000) N","methodology_en":"Shear modulus (single specimen set-up) Range: (20 - 50000) N","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moduł sprężystości poprzecznej (układ z pojedynczą próbką) Zakres: (20 - 50000) N","reference":"PN-EN 12090","norm_bases":["PN-EN 12090"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Moduł sprężystości poprzecznej (układ z pojedynczą próbką) Zakres: (20 - 50000) N PN-EN 12090 Wyroby z tworzyw sztucznych E Modul sprezystosci poprzecznej (uklad z pojedyncza probka) Zakres: (20 - 50000) N PN-EN 12090","categories":["other"],"row_index":1040,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Shear modulus (single specimen set-up) Range: (20 - 50000) N PN-EN 12090","search_zh":"塑料制品 E PN-EN 12090","test_object_zh":"塑料制品 E"},{"_id":"6a5a55f19af9f73f38251325","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Stabilność wymiarowa w określonych warunkach temperaturowych i wilgotnościowych Zakres: temp.: (-30 - 150)°C wilg. wzgl.: do 100%","methodology_en":"Dimensional stability under specified temperature and humidity conditions Range: temp.: (-30 - 150)°C rel. humidity: up to 100%","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stabilność wymiarowa w określonych warunkach temperaturowych i wilgotnościowych Zakres: temp.: (-30 - 150)°C wilg. wzgl.: do 100%","reference":"PN-EN 1604","norm_bases":["PN-EN 1604"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Stabilność wymiarowa w określonych warunkach temperaturowych i wilgotnościowych Zakres: temp.: (-30 - 150)°C wilg. wzgl.: do 100% PN-EN 1604 Wyroby z tworzyw sztucznych E Stabilnosc wymiarowa w okreslonych warunkach temperaturowych i wilgotnosciowych Zakres: temp.: (-30 - 150)°C wilg. wzgl.: do 100% PN-EN 1604","categories":["other"],"row_index":1041,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Dimensional stability under specified temperature and humidity conditions Range: temp.: (-30 - 150)°C rel. humidity: up to 100% PN-EN 1604","search_zh":"塑料制品 E PN-EN 1604","test_object_zh":"塑料制品 E"},{"_id":"6a5a55f19af9f73f38251326","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Właściwości przy ściskaniu Zakres: (20 - 50000) N","methodology_en":"Compressive properties Range: (20 - 50000) N","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Właściwości przy ściskaniu Zakres: (20 - 50000) N","reference":"PN-EN 29469","norm_bases":["PN-EN 29469"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Właściwości przy ściskaniu Zakres: (20 - 50000) N PN-EN 29469 Wyroby z tworzyw sztucznych E Wlasciwosci przy sciskaniu Zakres: (20 - 50000) N PN-EN 29469","categories":["other"],"row_index":1042,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Compressive properties Range: (20 - 50000) N PN-EN 29469","search_zh":"塑料制品 E PN-EN 29469","test_object_zh":"塑料制品 E"},{"_id":"6a5a55f19af9f73f38251327","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Wytrzymałość na rozciąganie prostopadłe do powierzchni czołowych","methodology_en":"Tensile strength perpendicular to the end faces","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na rozciąganie prostopadłe do powierzchni czołowych","reference":"PN-EN 1607","norm_bases":["PN-EN 1607"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Wytrzymałość na rozciąganie prostopadłe do powierzchni czołowych PN-EN 1607 Wyroby z tworzyw sztucznych E Wytrzymalosc na rozciaganie prostopadle do powierzchni czolowych PN-EN 1607","categories":["other"],"row_index":1043,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Tensile strength perpendicular to the end faces PN-EN 1607","search_zh":"塑料制品 E PN-EN 1607","test_object_zh":"塑料制品 E"},{"_id":"6a5a55f19af9f73f38251328","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych E","test_object_en":"Plastic products E","methodology":"Wytrzymałość na ścinanie (układ z pojedynczą próbką) Zakres: (20 - 50000) N","methodology_en":"Shear strength (single specimen arrangement) Range: (20 - 50000) N","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ścinanie (układ z pojedynczą próbką) Zakres: (20 - 50000) N","reference":"PN-EN 12090","norm_bases":["PN-EN 12090"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych E Wytrzymałość na ścinanie (układ z pojedynczą próbką) Zakres: (20 - 50000) N PN-EN 12090 Wyroby z tworzyw sztucznych E Wytrzymalosc na scinanie (uklad z pojedyncza probka) Zakres: (20 - 50000) N PN-EN 12090","categories":["other"],"row_index":1044,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic products E Shear strength (single specimen arrangement) Range: (20 - 50000) N PN-EN 12090","search_zh":"塑料制品 E PN-EN 12090","test_object_zh":"塑料制品 E"},{"_id":"6a5a55f19af9f73f38251329","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby ogniochronne reaktywne E","test_object_en":"Reactive fire protection products E","methodology":"Masa powierzchniowa Zakres: (0,001 - 10) kg Metoda wagowa","methodology_en":"Mass per unit area Range: (0,001 - 10) kg Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Masa powierzchniowa Zakres: (0,001 - 10) kg Metoda wagowa","reference":"EAD 350005-00-1104","norm_bases":["EAD 350005-00-1104"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby ogniochronne reaktywne E Masa powierzchniowa Zakres: (0,001 - 10) kg Metoda wagowa EAD 350005-00-1104 Wyroby ogniochronne reaktywne E Masa powierzchniowa Zakres: (0,001 - 10) kg Metoda wagowa EAD 350005-00-1104","categories":["other"],"row_index":1045,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Reactive fire protection products E Mass per unit area Range: (0,001 - 10) kg Gravimetric method EAD 350005-00-1104"},{"_id":"6a5a55f19af9f73f3825132a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby ogniochronne reaktywne E","test_object_en":"Reactive fire protection products E","methodology":"Odporność oddziaływanie cyklicznie zmiennych warunków środowiskowych Zakres: temperatura do 80ºC wilgotność wzgl. do 90% typ wyrobu Z1, Z2, Y2 i Y1","methodology_en":"Resistance to the action of cyclically changing environmental conditions Range: temperature up to 80ºC rel. humidity up to 90% product type Z1, Z2, Y2 and Y1","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność oddziaływanie cyklicznie zmiennych warunków środowiskowych Zakres: temperatura do 80ºC wilgotność wzgl. do 90% typ wyrobu Z1, Z2, Y2 i Y1","reference":"EAD 350005-00-1104 EAD 350003-00-1109","norm_bases":["EAD 350005-00-1104 EAD 350003-00-1109"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby ogniochronne reaktywne E Odporność oddziaływanie cyklicznie zmiennych warunków środowiskowych Zakres: temperatura do 80ºC wilgotność wzgl. do 90% typ wyrobu Z1, Z2, Y2 i Y1 EAD 350005-00-1104 EAD 350003-00-1109 Wyroby ogniochronne reaktywne E Odpornosc oddzialywanie cyklicznie zmiennych warunkow srodowiskowych Zakres: temperatura do 80ºC wilgotnosc wzgl. do 90% typ wyrobu Z1, Z2, Y2 i Y1 EAD 350005-00-1104 EAD 350003-00-1109","categories":["environment"],"row_index":1046,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Reactive fire protection products E Resistance to the action of cyclically changing environmental conditions Range: temperature up to 80ºC rel. humidity up to 90% product type Z1, Z2, Y2 and Y1 EAD 350005-00-1104 EAD 350003-00-1109"},{"_id":"6a5a55f19af9f73f3825132b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Autonomiczne czujki dymu","test_object_en":"Smoke alarm devices","methodology":"Cechy autonomicznej czujki dymu według Tablicy ZA.1 normy, z wyjątkiem pkt 5.24.12 czujki z nap. zasilania <=34V","methodology_en":"Features of the smoke alarm device according to Table ZA.1 of the standard, excluding clause 5.24.12 for detectors with a supply voltage <=34V","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cechy autonomicznej czujki dymu według Tablicy ZA.1 normy, z wyjątkiem pkt 5.24.12 czujki z nap. zasilania <=34V","reference":"PN-EN 14604:2006+AC:2009 w tym : pkt. 5.10 PN-EN 60068-2-42:2004 pkt. 5.12 i 5.13 PN-EN 60068-2-6:2008 pkt. 5.14 PN-EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03","norm_bases":["PN-EN 14604:2006+AC:2009 w tym : pkt. 5.10 PN-EN 60068-2-42:2004 pkt. 5.12 i 5.13 PN-EN 60068-2-6:2008 pkt. 5.14 PN-EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Autonomiczne czujki dymu Cechy autonomicznej czujki dymu według Tablicy ZA.1 normy, z wyjątkiem pkt 5.24.12 czujki z nap. zasilania <=34V PN-EN 14604:2006+AC:2009 w tym : pkt. 5.10 PN-EN 60068-2-42:2004 pkt. 5.12 i 5.13 PN-EN 60068-2-6:2008 pkt. 5.14 PN-EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03 Autonomiczne czujki dymu Cechy autonomicznej czujki dymu wedlug Tablicy ZA.1 normy, z wyjatkiem pkt 5.24.12 czujki z nap. zasilania <=34V PN-EN 14604:2006+AC:2009 w tym : pkt. 5.10 PN-EN 60068-2-42:2004 pkt. 5.12 i 5.13 PN-EN 60068-2-6:2008 pkt. 5.14 PN-EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03","categories":["other"],"row_index":1047,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Smoke alarm devices Features of the smoke alarm device according to Table ZA.1 of the standard, excluding clause 5.24.12 for detectors with a supply voltage <=34V PN-EN 14604:2006+AC:2009 w tym : pkt. 5.10 PN-EN 60068-2-42:2004 pkt. 5.12 i 5.13 PN-EN 60068-2-6:2008 pkt. 5.14 PN-EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03"},{"_id":"6a5a55f19af9f73f3825132c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Centrala oraz instalacja dźwiękowego systemu ostrzegawczego","test_object_en":"Voice alarm system control and indicating equipment and installation","methodology":"Cechy centrali dźwiękowego systemu ostrzegawczego według Tablicy ZA.1 normy","methodology_en":"Features of the voice alarm control and indicating equipment according to Table ZA.1 of the standard","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cechy centrali dźwiękowego systemu ostrzegawczego według Tablicy ZA.1 normy","reference":"PN-EN 54-16:2011 w tym: pkt. 13.3 z wykorzystaniem PN EN 60529:2003 pkt.16.8 z wykorzystaniem PN EN 60068-2-1:2009 pkt 16. 9 i 16.10 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt. 16.11 z wykorzystaniem PN-EN 60068-2-75:2015-01 pkt. 16.12 i 16.13 z wykorzystaniem PN-EN 60068-2-6:2008 pkt. 16.14 z wykorzystaniem PN-EN 54-4:2001 + A1:2004 + A2:2007 pkt. 16.15 z wykorzystaniem PN-EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03","norm_bases":["PN-EN 54-16:2011 w tym: pkt. 13.3 z wykorzystaniem PN EN 60529:2003 pkt.16.8 z wykorzystaniem PN EN 60068-2-1:2009 pkt 16. 9 i 16.10 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt. 16.11 z wykorzystaniem PN-EN 60068-2-75:2015-01 pkt. 16.12 i 16.13 z wykorzystaniem PN-EN 60068-2-6:2008 pkt. 16.14 z wykorzystaniem PN-EN 54-4:2001 + A1:2004 + A2:2007 pkt. 16.15 z wykorzystaniem PN-EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Centrala oraz instalacja dźwiękowego systemu ostrzegawczego Cechy centrali dźwiękowego systemu ostrzegawczego według Tablicy ZA.1 normy PN-EN 54-16:2011 w tym: pkt. 13.3 z wykorzystaniem PN EN 60529:2003 pkt.16.8 z wykorzystaniem PN EN 60068-2-1:2009 pkt 16. 9 i 16.10 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt. 16.11 z wykorzystaniem PN-EN 60068-2-75:2015-01 pkt. 16.12 i 16.13 z wykorzystaniem PN-EN 60068-2-6:2008 pkt. 16.14 z wykorzystaniem PN-EN 54-4:2001 + A1:2004 + A2:2007 pkt. 16.15 z wykorzystaniem PN-EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03 Centrala oraz instalacja dzwiekowego systemu ostrzegawczego Cechy centrali dzwiekowego systemu ostrzegawczego wedlug Tablicy ZA.1 normy PN-EN 54-16:2011 w tym: pkt. 13.3 z wykorzystaniem PN EN 60529:2003 pkt.16.8 z wykorzystaniem PN EN 60068-2-1:2009 pkt 16. 9 i 16.10 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt. 16.11 z wykorzystaniem PN-EN 60068-2-75:2015-01 pkt. 16.12 i 16.13 z wykorzystaniem PN-EN 60068-2-6:2008 pkt. 16.14 z wykorzystaniem PN-EN 54-4:2001 + A1:2004 + A2:2007 pkt. 16.15 z wykorzystaniem PN-EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03","categories":["other"],"row_index":1048,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Voice alarm system control and indicating equipment and installation Features of the voice alarm control and indicating equipment according to Table ZA.1 of the standard PN-EN 54-16:2011 w tym: pkt. 13.3 z wykorzystaniem PN EN 60529:2003 pkt.16.8 z wykorzystaniem PN EN 60068-2-1:2009 pkt 16. 9 i 16.10 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt. 16.11 z wykorzystaniem PN-EN 60068-2-75:2015-01 pkt. 16.12 i 16.13 z wykorzystaniem PN-EN 60068-2-6:2008 pkt. 16.14 z wykorzystaniem PN-EN 54-4:2001 + A1:2004 + A2:2007 pkt. 16.15 z wykorzystaniem PN-EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03"},{"_id":"6a5a55f19af9f73f3825132d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Centrale sygnalizacji pożarowej","test_object_en":"Fire detection and fire alarm control and indicating equipment","methodology":"Cechy centrali sygnalizacji pożarowej według Tablicy ZA.1 normy","methodology_en":"Features of the fire detection control and indicating equipment according to Table ZA.1 of the standard","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cechy centrali sygnalizacji pożarowej według Tablicy ZA.1 normy","reference":"EN 54-2:2002 +A1:2007 w tym: pkt. 12.3 z wykorzystaniem PN-EN 60529:2003 pkt. 15.4 z wykorzystaniem PN EN 60068-2-1:2009 pkt.15.5 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt. 15.6 z wykorzystaniem PN-EN 60068-2-75:2015-01 pkt. 15.7 i 15.15 z wykorzystaniem PN-EN 60068-2-6:2008 pkt.15.8 z wykorzystaniem PN-EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03","norm_bases":["EN 54-2:2002 +A1:2007 w tym: pkt. 12.3 z wykorzystaniem PN-EN 60529:2003 pkt. 15.4 z wykorzystaniem PN EN 60068-2-1:2009 pkt.15.5 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt. 15.6 z wykorzystaniem PN-EN 60068-2-75:2015-01 pkt. 15.7 i 15.15 z wykorzystaniem PN-EN 60068-2-6:2008 pkt.15.8 z wykorzystaniem PN-EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Centrale sygnalizacji pożarowej Cechy centrali sygnalizacji pożarowej według Tablicy ZA.1 normy EN 54-2:2002 +A1:2007 w tym: pkt. 12.3 z wykorzystaniem PN-EN 60529:2003 pkt. 15.4 z wykorzystaniem PN EN 60068-2-1:2009 pkt.15.5 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt. 15.6 z wykorzystaniem PN-EN 60068-2-75:2015-01 pkt. 15.7 i 15.15 z wykorzystaniem PN-EN 60068-2-6:2008 pkt.15.8 z wykorzystaniem PN-EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03 Centrale sygnalizacji pozarowej Cechy centrali sygnalizacji pozarowej wedlug Tablicy ZA.1 normy EN 54-2:2002 +A1:2007 w tym: pkt. 12.3 z wykorzystaniem PN-EN 60529:2003 pkt. 15.4 z wykorzystaniem PN EN 60068-2-1:2009 pkt.15.5 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt. 15.6 z wykorzystaniem PN-EN 60068-2-75:2015-01 pkt. 15.7 i 15.15 z wykorzystaniem PN-EN 60068-2-6:2008 pkt.15.8 z wykorzystaniem PN-EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03","categories":["other"],"row_index":1049,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fire detection and fire alarm control and indicating equipment Features of the fire detection control and indicating equipment according to Table ZA.1 of the standard EN 54-2:2002 +A1:2007 w tym: pkt. 12.3 z wykorzystaniem PN-EN 60529:2003 pkt. 15.4 z wykorzystaniem PN EN 60068-2-1:2009 pkt.15.5 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt. 15.6 z wykorzystaniem PN-EN 60068-2-75:2015-01 pkt. 15.7 i 15.15 z wykorzystaniem PN-EN 60068-2-6:2008 pkt.15.8 z wykorzystaniem PN-EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03"},{"_id":"6a5a55f19af9f73f3825132e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Czujka ciepła punktowa","test_object_en":"Point heat detector","methodology":"Cechy czujki ciepła punktowej według Tablicy ZA.1 normy","methodology_en":"Features of the point heat detector according to Table ZA.1 of the standard","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cechy czujki ciepła punktowej według Tablicy ZA.1 normy","reference":"PN-EN 54-5 +A1:2018-11 W tym pkt 5.6.1.1 z wykorzystaniem PN EN 60068-2-1:2009 pkt. 5.6.1.2 z wykorzystaniem PN-EN 60068-2-2:2009 pkt 5.6.2.1 z wykorzystaniem PN–EN 60068-2-30:2008 pkt.5.6.2.2 z wykorzystaniem PN-EN 60068-2-78:2013-11E pkt. 5.6.3.1 z wykorzystaniem PN-EN 60068-2-42:2004 pkt 5.6.4.1 z wykorzystaniem PN-EN 60068-2-27:2009 pkt 5.6.4.3 i 5.6.4.4 z wykorzystaniem PN-EN 60068-2-6:2008 pkt 5.6.5.1 z wykorzystaniem PN-EN 50130-4:2012+A1:2015-03","norm_bases":["PN-EN 54-5 +A1:2018-11 W tym pkt 5.6.1.1 z wykorzystaniem PN EN 60068-2-1:2009 pkt. 5.6.1.2 z wykorzystaniem PN-EN 60068-2-2:2009 pkt 5.6.2.1 z wykorzystaniem PN–EN 60068-2-30:2008 pkt.5.6.2.2 z wykorzystaniem PN-EN 60068-2-78:2013-11E pkt. 5.6.3.1 z wykorzystaniem PN-EN 60068-2-42:2004 pkt 5.6.4.1 z wykorzystaniem PN-EN 60068-2-27:2009 pkt 5.6.4.3 i 5.6.4.4 z wykorzystaniem PN-EN 60068-2-6:2008 pkt 5.6.5.1 z wykorzystaniem PN-EN 50130-4:2012+A1:2015-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Czujka ciepła punktowa Cechy czujki ciepła punktowej według Tablicy ZA.1 normy PN-EN 54-5 +A1:2018-11 W tym pkt 5.6.1.1 z wykorzystaniem PN EN 60068-2-1:2009 pkt. 5.6.1.2 z wykorzystaniem PN-EN 60068-2-2:2009 pkt 5.6.2.1 z wykorzystaniem PN–EN 60068-2-30:2008 pkt.5.6.2.2 z wykorzystaniem PN-EN 60068-2-78:2013-11E pkt. 5.6.3.1 z wykorzystaniem PN-EN 60068-2-42:2004 pkt 5.6.4.1 z wykorzystaniem PN-EN 60068-2-27:2009 pkt 5.6.4.3 i 5.6.4.4 z wykorzystaniem PN-EN 60068-2-6:2008 pkt 5.6.5.1 z wykorzystaniem PN-EN 50130-4:2012+A1:2015-03 Czujka ciepla punktowa Cechy czujki ciepla punktowej wedlug Tablicy ZA.1 normy PN-EN 54-5 +A1:2018-11 W tym pkt 5.6.1.1 z wykorzystaniem PN EN 60068-2-1:2009 pkt. 5.6.1.2 z wykorzystaniem PN-EN 60068-2-2:2009 pkt 5.6.2.1 z wykorzystaniem PN–EN 60068-2-30:2008 pkt.5.6.2.2 z wykorzystaniem PN-EN 60068-2-78:2013-11E pkt. 5.6.3.1 z wykorzystaniem PN-EN 60068-2-42:2004 pkt 5.6.4.1 z wykorzystaniem PN-EN 60068-2-27:2009 pkt 5.6.4.3 i 5.6.4.4 z wykorzystaniem PN-EN 60068-2-6:2008 pkt 5.6.5.1 z wykorzystaniem PN-EN 50130-4:2012+A1:2015-03","categories":["other"],"row_index":1050,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Point heat detector Features of the point heat detector according to Table ZA.1 of the standard PN-EN 54-5 +A1:2018-11 W tym pkt 5.6.1.1 z wykorzystaniem PN EN 60068-2-1:2009 pkt. 5.6.1.2 z wykorzystaniem PN-EN 60068-2-2:2009 pkt 5.6.2.1 z wykorzystaniem PN–EN 60068-2-30:2008 pkt.5.6.2.2 z wykorzystaniem PN-EN 60068-2-78:2013-11E pkt. 5.6.3.1 z wykorzystaniem PN-EN 60068-2-42:2004 pkt 5.6.4.1 z wykorzystaniem PN-EN 60068-2-27:2009 pkt 5.6.4.3 i 5.6.4.4 z wykorzystaniem PN-EN 60068-2-6:2008 pkt 5.6.5.1 z wykorzystaniem PN-EN 50130-4:2012+A1:2015-03"},{"_id":"6a5a55f19af9f73f3825132f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Czujka dymu liniowa","test_object_en":"Line-type smoke detector","methodology":"Cechy czujki dymu liniowej według Tablicy ZA.1 normy","methodology_en":"Features of the line smoke detector according to Table ZA.1 of the standard","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cechy czujki dymu liniowej według Tablicy ZA.1 normy","reference":"PN-EN 54-12:2015-05 w tym pkt. 5.6.1.1 z wykorzystaniem PN-EN 60068-2-2:2009 pkt 5.6.1.2 z wykorzystaniem PN EN 60068-2-1:2009 pkt. 5.6.2.1 i 5.6.2.2 z wykorzystaniem PN EN 60068-2-78:2013-11E pkt 5.6.3.1 z wykorzystaniem PN-EN 60068-2-6:2008 pkt 5.6.3.2 z wykorzystaniem PN-EN 60068-2-75:2015-01 pkt.5.6.4 z wykorzystaniem PN-EN 50130-4:2012+A1:2015-03 pkt. 5.6.5 z wykorzystaniem PN-EN 60068-2-42:2004","norm_bases":["PN-EN 54-12:2015-05 w tym pkt. 5.6.1.1 z wykorzystaniem PN-EN 60068-2-2:2009 pkt 5.6.1.2 z wykorzystaniem PN EN 60068-2-1:2009 pkt. 5.6.2.1 i 5.6.2.2 z wykorzystaniem PN EN 60068-2-78:2013-11E pkt 5.6.3.1 z wykorzystaniem PN-EN 60068-2-6:2008 pkt 5.6.3.2 z wykorzystaniem PN-EN 60068-2-75:2015-01 pkt.5.6.4 z wykorzystaniem PN-EN 50130-4:2012+A1:2015-03 pkt. 5.6.5 z wykorzystaniem PN-EN 60068-2-42:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Czujka dymu liniowa Cechy czujki dymu liniowej według Tablicy ZA.1 normy PN-EN 54-12:2015-05 w tym pkt. 5.6.1.1 z wykorzystaniem PN-EN 60068-2-2:2009 pkt 5.6.1.2 z wykorzystaniem PN EN 60068-2-1:2009 pkt. 5.6.2.1 i 5.6.2.2 z wykorzystaniem PN EN 60068-2-78:2013-11E pkt 5.6.3.1 z wykorzystaniem PN-EN 60068-2-6:2008 pkt 5.6.3.2 z wykorzystaniem PN-EN 60068-2-75:2015-01 pkt.5.6.4 z wykorzystaniem PN-EN 50130-4:2012+A1:2015-03 pkt. 5.6.5 z wykorzystaniem PN-EN 60068-2-42:2004 Czujka dymu liniowa Cechy czujki dymu liniowej wedlug Tablicy ZA.1 normy PN-EN 54-12:2015-05 w tym pkt. 5.6.1.1 z wykorzystaniem PN-EN 60068-2-2:2009 pkt 5.6.1.2 z wykorzystaniem PN EN 60068-2-1:2009 pkt. 5.6.2.1 i 5.6.2.2 z wykorzystaniem PN EN 60068-2-78:2013-11E pkt 5.6.3.1 z wykorzystaniem PN-EN 60068-2-6:2008 pkt 5.6.3.2 z wykorzystaniem PN-EN 60068-2-75:2015-01 pkt.5.6.4 z wykorzystaniem PN-EN 50130-4:2012+A1:2015-03 pkt. 5.6.5 z wykorzystaniem PN-EN 60068-2-42:2004","categories":["other"],"row_index":1051,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Line-type smoke detector Features of the line smoke detector according to Table ZA.1 of the standard PN-EN 54-12:2015-05 w tym pkt. 5.6.1.1 z wykorzystaniem PN-EN 60068-2-2:2009 pkt 5.6.1.2 z wykorzystaniem PN EN 60068-2-1:2009 pkt. 5.6.2.1 i 5.6.2.2 z wykorzystaniem PN EN 60068-2-78:2013-11E pkt 5.6.3.1 z wykorzystaniem PN-EN 60068-2-6:2008 pkt 5.6.3.2 z wykorzystaniem PN-EN 60068-2-75:2015-01 pkt.5.6.4 z wykorzystaniem PN-EN 50130-4:2012+A1:2015-03 pkt. 5.6.5 z wykorzystaniem PN-EN 60068-2-42:2004"},{"_id":"6a5a55f19af9f73f38251330","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Czujka dymu punktowa","test_object_en":"Point smoke detector","methodology":"Cechy czujki dymu punktowej według Tablicy ZA.1 normy","methodology_en":"Features of the point smoke detector according to Table ZA.1 of the standard","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cechy czujki dymu punktowej według Tablicy ZA.1 normy","reference":"PN-EN 54-7:2018-11 w tym pkt. 5.9 z wykorzystaniem PN-EN 60068-2-1:2009 pkt.5.10 i 5.11 z wykorzystaniem PN EN 60068-2-78:2013E pkt. 5.12 z wykorzystaniem PN-EN 60068-2-42:2004 pkt 5.13 z wykorzystaniem PN-EN 60068-2-27:2009 pkt.5.15 i 5.16 z wykorzystaniem PN EN 60068-2-6:2008 pkt 5.17 z wykorzystaniem PN-EN 50130-4:2012+A1:2015-03","norm_bases":["PN-EN 54-7:2018-11 w tym pkt. 5.9 z wykorzystaniem PN-EN 60068-2-1:2009 pkt.5.10 i 5.11 z wykorzystaniem PN EN 60068-2-78:2013E pkt. 5.12 z wykorzystaniem PN-EN 60068-2-42:2004 pkt 5.13 z wykorzystaniem PN-EN 60068-2-27:2009 pkt.5.15 i 5.16 z wykorzystaniem PN EN 60068-2-6:2008 pkt 5.17 z wykorzystaniem PN-EN 50130-4:2012+A1:2015-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Czujka dymu punktowa Cechy czujki dymu punktowej według Tablicy ZA.1 normy PN-EN 54-7:2018-11 w tym pkt. 5.9 z wykorzystaniem PN-EN 60068-2-1:2009 pkt.5.10 i 5.11 z wykorzystaniem PN EN 60068-2-78:2013E pkt. 5.12 z wykorzystaniem PN-EN 60068-2-42:2004 pkt 5.13 z wykorzystaniem PN-EN 60068-2-27:2009 pkt.5.15 i 5.16 z wykorzystaniem PN EN 60068-2-6:2008 pkt 5.17 z wykorzystaniem PN-EN 50130-4:2012+A1:2015-03 Czujka dymu punktowa Cechy czujki dymu punktowej wedlug Tablicy ZA.1 normy PN-EN 54-7:2018-11 w tym pkt. 5.9 z wykorzystaniem PN-EN 60068-2-1:2009 pkt.5.10 i 5.11 z wykorzystaniem PN EN 60068-2-78:2013E pkt. 5.12 z wykorzystaniem PN-EN 60068-2-42:2004 pkt 5.13 z wykorzystaniem PN-EN 60068-2-27:2009 pkt.5.15 i 5.16 z wykorzystaniem PN EN 60068-2-6:2008 pkt 5.17 z wykorzystaniem PN-EN 50130-4:2012+A1:2015-03","categories":["other"],"row_index":1052,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Point smoke detector Features of the point smoke detector according to Table ZA.1 of the standard PN-EN 54-7:2018-11 w tym pkt. 5.9 z wykorzystaniem PN-EN 60068-2-1:2009 pkt.5.10 i 5.11 z wykorzystaniem PN EN 60068-2-78:2013E pkt. 5.12 z wykorzystaniem PN-EN 60068-2-42:2004 pkt 5.13 z wykorzystaniem PN-EN 60068-2-27:2009 pkt.5.15 i 5.16 z wykorzystaniem PN EN 60068-2-6:2008 pkt 5.17 z wykorzystaniem PN-EN 50130-4:2012+A1:2015-03"},{"_id":"6a5a55f19af9f73f38251331","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu","test_object_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console","methodology":"Próba Kc - Oddziaływanie dwutlenku siarki na styki i połączenia","methodology_en":"Test Kc - Sulfur dioxide test for contacts and connections","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Próba Kc - Oddziaływanie dwutlenku siarki na styki i połączenia","reference":"PN-EN 60068-2-42:2004","norm_bases":["PN-EN 60068-2-42:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu Próba Kc - Oddziaływanie dwutlenku siarki na styki i połączenia PN-EN 60068-2-42:2004 Elementy i systemy automatyki, sygnalizacji pozarowej, instalacji elektrycznych, urzadzen elektrycznych i elektronicznych W tym miedzy innymi:  Centrala sterujaca urzadzeniami oddymiajacymi i przewietrzajacymi, sterownik wentylacji oddymiajacej  Centrala sterujaca urzadzeniami przeciwpozarowymi  Reczny przycisk oddymiania  Siec central sygnalizacji pozarowej  Systemy integrujace  Tablica sygnalizacji rownoleglej  Urzadzenia zasilajace w systemach automatyki pozarowej  Urzadzenie zdalnej sygnalizacji i obslugi  Wyniesiony mikrofon strazaka, konsola operatora systemu Proba Kc - Oddzialywanie dwutlenku siarki na styki i polaczenia PN-EN 60068-2-42:2004","categories":["electronics"],"row_index":1053,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console Test Kc - Sulfur dioxide test for contacts and connections PN-EN 60068-2-42:2004","search_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台 PN-EN 60068-2-42:2004","test_object_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台"},{"_id":"6a5a55f19af9f73f38251332","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu","test_object_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console","methodology":"Odporność na pole elektromagnetyczne o częstotliwości radiowej w zakresie częstotliwości od 80 MHz do 1 GHz przy natężeniu pola do 30 V/m","methodology_en":"Immunity to radio-frequency electromagnetic field in the frequency range from 80 MHz to 1 GHz at a field strength up to 30 V/m","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na pole elektromagnetyczne o częstotliwości radiowej w zakresie częstotliwości od 80 MHz do 1 GHz przy natężeniu pola do 30 V/m","reference":"PN-EN 61000-4-3:2007+ A1:2008 + A2:2011 + IS1:2009 PN-EN IEC 61000-4-3:2021-06 PN-EN 50130-4:2012+ A1:2015-03","norm_bases":["PN-EN 61000-4-3:2007+ A1:2008 + A2:2011 + IS1:2009 PN-EN IEC 61000-4-3:2021-06 PN-EN 50130-4:2012+ A1:2015-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu Odporność na pole elektromagnetyczne o częstotliwości radiowej w zakresie częstotliwości od 80 MHz do 1 GHz przy natężeniu pola do 30 V/m PN-EN 61000-4-3:2007+ A1:2008 + A2:2011 + IS1:2009 PN-EN IEC 61000-4-3:2021-06 PN-EN 50130-4:2012+ A1:2015-03 Elementy i systemy automatyki, sygnalizacji pozarowej, instalacji elektrycznych, urzadzen elektrycznych i elektronicznych W tym miedzy innymi:  Centrala sterujaca urzadzeniami oddymiajacymi i przewietrzajacymi, sterownik wentylacji oddymiajacej  Centrala sterujaca urzadzeniami przeciwpozarowymi  Reczny przycisk oddymiania  Siec central sygnalizacji pozarowej  Systemy integrujace  Tablica sygnalizacji rownoleglej  Urzadzenia zasilajace w systemach automatyki pozarowej  Urzadzenie zdalnej sygnalizacji i obslugi  Wyniesiony mikrofon strazaka, konsola operatora systemu Odpornosc na pole elektromagnetyczne o czestotliwosci radiowej w zakresie czestotliwosci od 80 MHz do 1 GHz przy natezeniu pola do 30 V/m PN-EN 61000-4-3:2007+ A1:2008 + A2:2011 + IS1:2009 PN-EN IEC 61000-4-3:2021-06 PN-EN 50130-4:2012+ A1:2015-03","categories":["electronics"],"row_index":1054,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console Immunity to radio-frequency electromagnetic field in the frequency range from 80 MHz to 1 GHz at a field strength up to 30 V/m PN-EN 61000-4-3:2007+ A1:2008 + A2:2011 + IS1:2009 PN-EN IEC 61000-4-3:2021-06 PN-EN 50130-4:2012+ A1:2015-03","search_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台 PN-EN 61000-4-3:2007+ A1:2008 + A2:2011 + IS1:2009 PN-EN IEC 61000-4-3:2021-06 PN-EN 50130-4:2012+ A1:2015-03","test_object_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台"},{"_id":"6a5a55f19af9f73f38251333","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu","test_object_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console","methodology":"Odporność na pole elektromagnetyczne o częstotliwości radiowej w zakresie częstotliwości od 1 GHz do 3 GHz przy natężeniu pola do 20 V/m w obszarze pomiarowym o wymiarach (przy odchyleniu +/-3dB): 1,15 x 1,15 x 0,60 [m]","methodology_en":"Immunity to radio-frequency electromagnetic field in the frequency range from 1 GHz to 3 GHz at a field strength up to 20 V/m in a test area of dimensions (with a deviation of +/-3dB): 1,15 x 1,15 x 0,60 [m]","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na pole elektromagnetyczne o częstotliwości radiowej w zakresie częstotliwości od 1 GHz do 3 GHz przy natężeniu pola do 20 V/m w obszarze pomiarowym o wymiarach (przy odchyleniu +/-3dB): 1,15 x 1,15 x 0,60 [m]","reference":"PN-EN 61000-4-3:2007+ A1:2008 + A2:2011 + IS1:2009 PN-EN IEC 61000-4-3:2021-06 PN-EN 50130-4:2012+ A1:2015-03","norm_bases":["PN-EN 61000-4-3:2007+ A1:2008 + A2:2011 + IS1:2009 PN-EN IEC 61000-4-3:2021-06 PN-EN 50130-4:2012+ A1:2015-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu Odporność na pole elektromagnetyczne o częstotliwości radiowej w zakresie częstotliwości od 1 GHz do 3 GHz przy natężeniu pola do 20 V/m w obszarze pomiarowym o wymiarach (przy odchyleniu +/-3dB): 1,15 x 1,15 x 0,60 [m] PN-EN 61000-4-3:2007+ A1:2008 + A2:2011 + IS1:2009 PN-EN IEC 61000-4-3:2021-06 PN-EN 50130-4:2012+ A1:2015-03 Elementy i systemy automatyki, sygnalizacji pozarowej, instalacji elektrycznych, urzadzen elektrycznych i elektronicznych W tym miedzy innymi:  Centrala sterujaca urzadzeniami oddymiajacymi i przewietrzajacymi, sterownik wentylacji oddymiajacej  Centrala sterujaca urzadzeniami przeciwpozarowymi  Reczny przycisk oddymiania  Siec central sygnalizacji pozarowej  Systemy integrujace  Tablica sygnalizacji rownoleglej  Urzadzenia zasilajace w systemach automatyki pozarowej  Urzadzenie zdalnej sygnalizacji i obslugi  Wyniesiony mikrofon strazaka, konsola operatora systemu Odpornosc na pole elektromagnetyczne o czestotliwosci radiowej w zakresie czestotliwosci od 1 GHz do 3 GHz przy natezeniu pola do 20 V/m w obszarze pomiarowym o wymiarach (przy odchyleniu +/-3dB): 1,15 x 1,15 x 0,60 [m] PN-EN 61000-4-3:2007+ A1:2008 + A2:2011 + IS1:2009 PN-EN IEC 61000-4-3:2021-06 PN-EN 50130-4:2012+ A1:2015-03","categories":["electronics"],"row_index":1055,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console Immunity to radio-frequency electromagnetic field in the frequency range from 1 GHz to 3 GHz at a field strength up to 20 V/m in a test area of dimensions (with a deviation of +/-3dB): 1,15 x 1,15 x 0,60 [m] PN-EN 61000-4-3:2007+ A1:2008 + A2:2011 + IS1:2009 PN-EN IEC 61000-4-3:2021-06 PN-EN 50130-4:2012+ A1:2015-03","search_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台 PN-EN 61000-4-3:2007+ A1:2008 + A2:2011 + IS1:2009 PN-EN IEC 61000-4-3:2021-06 PN-EN 50130-4:2012+ A1:2015-03","test_object_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台"},{"_id":"6a5a55f19af9f73f38251334","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu","test_object_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console","methodology":"Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej","methodology_en":"Immunity to power-frequency magnetic field","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej","reference":"PN-EN 61000-4-8:2010","norm_bases":["PN-EN 61000-4-8:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej PN-EN 61000-4-8:2010 Elementy i systemy automatyki, sygnalizacji pozarowej, instalacji elektrycznych, urzadzen elektrycznych i elektronicznych W tym miedzy innymi:  Centrala sterujaca urzadzeniami oddymiajacymi i przewietrzajacymi, sterownik wentylacji oddymiajacej  Centrala sterujaca urzadzeniami przeciwpozarowymi  Reczny przycisk oddymiania  Siec central sygnalizacji pozarowej  Systemy integrujace  Tablica sygnalizacji rownoleglej  Urzadzenia zasilajace w systemach automatyki pozarowej  Urzadzenie zdalnej sygnalizacji i obslugi  Wyniesiony mikrofon strazaka, konsola operatora systemu Odpornosc na pole magnetyczne o czestotliwosci sieci elektroenergetycznej PN-EN 61000-4-8:2010","categories":["electronics"],"row_index":1056,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console Immunity to power-frequency magnetic field PN-EN 61000-4-8:2010","search_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台 工频磁场抗扰度 PN-EN 61000-4-8:2010","test_object_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台","methodology_zh":"工频磁场抗扰度"},{"_id":"6a5a55f19af9f73f38251335","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu","test_object_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console","methodology":"Odporność na udary napięciowe (zakłócenia impulsowe dużej energii)","methodology_en":"Immunity to voltage surges (high-energy impulse disturbances)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na udary napięciowe (zakłócenia impulsowe dużej energii)","reference":"PN-EN 61000-4-5:2014-10+A1:2018- 01 PN-EN 50130-4:2012+ A1:2015-03","norm_bases":["PN-EN 61000-4-5:2014-10+A1:2018- 01 PN-EN 50130-4:2012+ A1:2015-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu Odporność na udary napięciowe (zakłócenia impulsowe dużej energii) PN-EN 61000-4-5:2014-10+A1:2018- 01 PN-EN 50130-4:2012+ A1:2015-03 Elementy i systemy automatyki, sygnalizacji pozarowej, instalacji elektrycznych, urzadzen elektrycznych i elektronicznych W tym miedzy innymi:  Centrala sterujaca urzadzeniami oddymiajacymi i przewietrzajacymi, sterownik wentylacji oddymiajacej  Centrala sterujaca urzadzeniami przeciwpozarowymi  Reczny przycisk oddymiania  Siec central sygnalizacji pozarowej  Systemy integrujace  Tablica sygnalizacji rownoleglej  Urzadzenia zasilajace w systemach automatyki pozarowej  Urzadzenie zdalnej sygnalizacji i obslugi  Wyniesiony mikrofon strazaka, konsola operatora systemu Odpornosc na udary napieciowe (zaklocenia impulsowe duzej energii) PN-EN 61000-4-5:2014-10+A1:2018- 01 PN-EN 50130-4:2012+ A1:2015-03","categories":["electronics"],"row_index":1057,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console Immunity to voltage surges (high-energy impulse disturbances) PN-EN 61000-4-5:2014-10+A1:2018- 01 PN-EN 50130-4:2012+ A1:2015-03","search_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台 PN-EN 61000-4-5:2014-10+A1:2018- 01 PN-EN 50130-4:2012+ A1:2015-03","test_object_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台"},{"_id":"6a5a55f19af9f73f38251336","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu","test_object_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console","methodology":"Odporność na wyładowania elektrostatyczne","methodology_en":"Immunity to electrostatic discharge","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na wyładowania elektrostatyczne","reference":"PN-EN 61000-4-2:2011 PN-EN 50130-4:2012+ A1:2015-03","norm_bases":["PN-EN 61000-4-2:2011 PN-EN 50130-4:2012+ A1:2015-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu Odporność na wyładowania elektrostatyczne PN-EN 61000-4-2:2011 PN-EN 50130-4:2012+ A1:2015-03 Elementy i systemy automatyki, sygnalizacji pozarowej, instalacji elektrycznych, urzadzen elektrycznych i elektronicznych W tym miedzy innymi:  Centrala sterujaca urzadzeniami oddymiajacymi i przewietrzajacymi, sterownik wentylacji oddymiajacej  Centrala sterujaca urzadzeniami przeciwpozarowymi  Reczny przycisk oddymiania  Siec central sygnalizacji pozarowej  Systemy integrujace  Tablica sygnalizacji rownoleglej  Urzadzenia zasilajace w systemach automatyki pozarowej  Urzadzenie zdalnej sygnalizacji i obslugi  Wyniesiony mikrofon strazaka, konsola operatora systemu Odpornosc na wyladowania elektrostatyczne PN-EN 61000-4-2:2011 PN-EN 50130-4:2012+ A1:2015-03","categories":["electronics"],"row_index":1058,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console Immunity to electrostatic discharge PN-EN 61000-4-2:2011 PN-EN 50130-4:2012+ A1:2015-03","search_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台 静电放电抗扰度 PN-EN 61000-4-2:2011 PN-EN 50130-4:2012+ A1:2015-03","test_object_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台","methodology_zh":"静电放电抗扰度"},{"_id":"6a5a55f19af9f73f38251337","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu","test_object_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console","methodology":"Odporność na zaburzenia przewodzone, indukowane przez pola o częstotliwości radiowej zakłócenia sinusoidalne przewodzone w zakresie częstotliwości od 150 kHz do 230 MHz","methodology_en":"Immunity to conducted disturbances, induced by radio-frequency fields conducted sinusoidal disturbances in the frequency range from 150 kHz to 230 MHz","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zaburzenia przewodzone, indukowane przez pola o częstotliwości radiowej zakłócenia sinusoidalne przewodzone w zakresie częstotliwości od 150 kHz do 230 MHz","reference":"PN-EN 61000-4-6:2014-04 PN-EN 61000-4-6:2024-03 PN-EN 50130-4:2012+ A1:2015-03","norm_bases":["PN-EN 61000-4-6:2014-04 PN-EN 61000-4-6:2024-03 PN-EN 50130-4:2012+ A1:2015-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu Odporność na zaburzenia przewodzone, indukowane przez pola o częstotliwości radiowej zakłócenia sinusoidalne przewodzone w zakresie częstotliwości od 150 kHz do 230 MHz PN-EN 61000-4-6:2014-04 PN-EN 61000-4-6:2024-03 PN-EN 50130-4:2012+ A1:2015-03 Elementy i systemy automatyki, sygnalizacji pozarowej, instalacji elektrycznych, urzadzen elektrycznych i elektronicznych W tym miedzy innymi:  Centrala sterujaca urzadzeniami oddymiajacymi i przewietrzajacymi, sterownik wentylacji oddymiajacej  Centrala sterujaca urzadzeniami przeciwpozarowymi  Reczny przycisk oddymiania  Siec central sygnalizacji pozarowej  Systemy integrujace  Tablica sygnalizacji rownoleglej  Urzadzenia zasilajace w systemach automatyki pozarowej  Urzadzenie zdalnej sygnalizacji i obslugi  Wyniesiony mikrofon strazaka, konsola operatora systemu Odpornosc na zaburzenia przewodzone, indukowane przez pola o czestotliwosci radiowej zaklocenia sinusoidalne przewodzone w zakresie czestotliwosci od 150 kHz do 230 MHz PN-EN 61000-4-6:2014-04 PN-EN 61000-4-6:2024-03 PN-EN 50130-4:2012+ A1:2015-03","categories":["electronics"],"row_index":1059,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console Immunity to conducted disturbances, induced by radio-frequency fields conducted sinusoidal disturbances in the frequency range from 150 kHz to 230 MHz PN-EN 61000-4-6:2014-04 PN-EN 61000-4-6:2024-03 PN-EN 50130-4:2012+ A1:2015-03","search_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台 PN-EN 61000-4-6:2014-04 PN-EN 61000-4-6:2024-03 PN-EN 50130-4:2012+ A1:2015-03","test_object_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台"},{"_id":"6a5a55f19af9f73f38251338","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu","test_object_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console","methodology":"Odporność na zakłócenia serią szybkich elektrycznych stanów przejściowych","methodology_en":"Immunity to electrical fast transient/burst disturbances","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zakłócenia serią szybkich elektrycznych stanów przejściowych","reference":"PN-EN 61000-4-4:2010 PN-EN 61000-4-4:2013-05 PN-EN 50130-4:2012+ A1:2015-03","norm_bases":["PN-EN 61000-4-4:2010 PN-EN 61000-4-4:2013-05 PN-EN 50130-4:2012+ A1:2015-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu Odporność na zakłócenia serią szybkich elektrycznych stanów przejściowych PN-EN 61000-4-4:2010 PN-EN 61000-4-4:2013-05 PN-EN 50130-4:2012+ A1:2015-03 Elementy i systemy automatyki, sygnalizacji pozarowej, instalacji elektrycznych, urzadzen elektrycznych i elektronicznych W tym miedzy innymi:  Centrala sterujaca urzadzeniami oddymiajacymi i przewietrzajacymi, sterownik wentylacji oddymiajacej  Centrala sterujaca urzadzeniami przeciwpozarowymi  Reczny przycisk oddymiania  Siec central sygnalizacji pozarowej  Systemy integrujace  Tablica sygnalizacji rownoleglej  Urzadzenia zasilajace w systemach automatyki pozarowej  Urzadzenie zdalnej sygnalizacji i obslugi  Wyniesiony mikrofon strazaka, konsola operatora systemu Odpornosc na zaklocenia seria szybkich elektrycznych stanow przejsciowych PN-EN 61000-4-4:2010 PN-EN 61000-4-4:2013-05 PN-EN 50130-4:2012+ A1:2015-03","categories":["electronics"],"row_index":1060,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console Immunity to electrical fast transient/burst disturbances PN-EN 61000-4-4:2010 PN-EN 61000-4-4:2013-05 PN-EN 50130-4:2012+ A1:2015-03","search_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台 PN-EN 61000-4-4:2010 PN-EN 61000-4-4:2013-05 PN-EN 50130-4:2012+ A1:2015-03","test_object_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台"},{"_id":"6a5a55f19af9f73f38251339","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu","test_object_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console","methodology":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia zasilania","methodology_en":"Immunity to voltage dips, short interruptions and supply voltage variations","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia zasilania","reference":"PN-EN 61000-4-11:2007+A1:2017-09 PN-EN IEC 61000-4-11:2020- 11+AC:2020-12+AC:2023-01 PN-EN 50130-4:2012+ A1:2015-03","norm_bases":["PN-EN 61000-4-11:2007+A1:2017-09 PN-EN IEC 61000-4-11:2020- 11+AC:2020-12+AC:2023-01 PN-EN 50130-4:2012+ A1:2015-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia zasilania PN-EN 61000-4-11:2007+A1:2017-09 PN-EN IEC 61000-4-11:2020- 11+AC:2020-12+AC:2023-01 PN-EN 50130-4:2012+ A1:2015-03 Elementy i systemy automatyki, sygnalizacji pozarowej, instalacji elektrycznych, urzadzen elektrycznych i elektronicznych W tym miedzy innymi:  Centrala sterujaca urzadzeniami oddymiajacymi i przewietrzajacymi, sterownik wentylacji oddymiajacej  Centrala sterujaca urzadzeniami przeciwpozarowymi  Reczny przycisk oddymiania  Siec central sygnalizacji pozarowej  Systemy integrujace  Tablica sygnalizacji rownoleglej  Urzadzenia zasilajace w systemach automatyki pozarowej  Urzadzenie zdalnej sygnalizacji i obslugi  Wyniesiony mikrofon strazaka, konsola operatora systemu Odpornosc na zapady napiecia, krotkie przerwy i zmiany napiecia zasilania PN-EN 61000-4-11:2007+A1:2017-09 PN-EN IEC 61000-4-11:2020- 11+AC:2020-12+AC:2023-01 PN-EN 50130-4:2012+ A1:2015-03","categories":["electronics"],"row_index":1061,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console Immunity to voltage dips, short interruptions and supply voltage variations PN-EN 61000-4-11:2007+A1:2017-09 PN-EN IEC 61000-4-11:2020- 11+AC:2020-12+AC:2023-01 PN-EN 50130-4:2012+ A1:2015-03","search_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台 PN-EN 61000-4-11:2007+A1:2017-09 PN-EN IEC 61000-4-11:2020- 11+AC:2020-12+AC:2023-01 PN-EN 50130-4:2012+ A1:2015-03","test_object_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台"},{"_id":"6a5a55f19af9f73f3825133a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu","test_object_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console","methodology":"Próba Db - wilgotne gorąco cykliczne – odporność","methodology_en":"Test Db - damp heat, cyclic – operational","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Próba Db - wilgotne gorąco cykliczne – odporność","reference":"PN-EN 60068-2-30:2008","norm_bases":["PN-EN 60068-2-30:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu Próba Db - wilgotne gorąco cykliczne – odporność PN-EN 60068-2-30:2008 Elementy i systemy automatyki, sygnalizacji pozarowej, instalacji elektrycznych, urzadzen elektrycznych i elektronicznych W tym miedzy innymi:  Centrala sterujaca urzadzeniami oddymiajacymi i przewietrzajacymi, sterownik wentylacji oddymiajacej  Centrala sterujaca urzadzeniami przeciwpozarowymi  Reczny przycisk oddymiania  Siec central sygnalizacji pozarowej  Systemy integrujace  Tablica sygnalizacji rownoleglej  Urzadzenia zasilajace w systemach automatyki pozarowej  Urzadzenie zdalnej sygnalizacji i obslugi  Wyniesiony mikrofon strazaka, konsola operatora systemu Proba Db - wilgotne goraco cykliczne – odpornosc PN-EN 60068-2-30:2008","categories":["electronics"],"row_index":1062,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console Test Db - damp heat, cyclic – operational PN-EN 60068-2-30:2008","search_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台 PN-EN 60068-2-30:2008","test_object_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台"},{"_id":"6a5a55f19af9f73f3825133b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu","test_object_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console","methodology":"Próba Db - wilgotne gorąco cykliczne – wytrzymałość","methodology_en":"Test Db - damp heat, cyclic – endurance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Próba Db - wilgotne gorąco cykliczne – wytrzymałość","reference":"PN-EN 60068-2-30:2008","norm_bases":["PN-EN 60068-2-30:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu Próba Db - wilgotne gorąco cykliczne – wytrzymałość PN-EN 60068-2-30:2008 Elementy i systemy automatyki, sygnalizacji pozarowej, instalacji elektrycznych, urzadzen elektrycznych i elektronicznych W tym miedzy innymi:  Centrala sterujaca urzadzeniami oddymiajacymi i przewietrzajacymi, sterownik wentylacji oddymiajacej  Centrala sterujaca urzadzeniami przeciwpozarowymi  Reczny przycisk oddymiania  Siec central sygnalizacji pozarowej  Systemy integrujace  Tablica sygnalizacji rownoleglej  Urzadzenia zasilajace w systemach automatyki pozarowej  Urzadzenie zdalnej sygnalizacji i obslugi  Wyniesiony mikrofon strazaka, konsola operatora systemu Proba Db - wilgotne goraco cykliczne – wytrzymalosc PN-EN 60068-2-30:2008","categories":["electronics"],"row_index":1063,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console Test Db - damp heat, cyclic – endurance PN-EN 60068-2-30:2008","search_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台 PN-EN 60068-2-30:2008","test_object_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台"},{"_id":"6a5a55f19af9f73f3825133c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu","test_object_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console","methodology":"Próba A - zimno- odporność","methodology_en":"Test A - cold - operational","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Próba A - zimno- odporność","reference":"PN-EN 60068-2-1:2009","norm_bases":["PN-EN 60068-2-1:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu Próba A - zimno- odporność PN-EN 60068-2-1:2009 Elementy i systemy automatyki, sygnalizacji pozarowej, instalacji elektrycznych, urzadzen elektrycznych i elektronicznych W tym miedzy innymi:  Centrala sterujaca urzadzeniami oddymiajacymi i przewietrzajacymi, sterownik wentylacji oddymiajacej  Centrala sterujaca urzadzeniami przeciwpozarowymi  Reczny przycisk oddymiania  Siec central sygnalizacji pozarowej  Systemy integrujace  Tablica sygnalizacji rownoleglej  Urzadzenia zasilajace w systemach automatyki pozarowej  Urzadzenie zdalnej sygnalizacji i obslugi  Wyniesiony mikrofon strazaka, konsola operatora systemu Proba A - zimno- odpornosc PN-EN 60068-2-1:2009","categories":["electronics"],"row_index":1064,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console Test A - cold - operational PN-EN 60068-2-1:2009","search_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台 PN-EN 60068-2-1:2009","test_object_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台"},{"_id":"6a5a55f19af9f73f3825133d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu","test_object_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console","methodology":"Próba B - suche gorąco – wytrzymałość","methodology_en":"Test B - dry heat – endurance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Próba B - suche gorąco – wytrzymałość","reference":"PN-EN 60068-2-2:2009","norm_bases":["PN-EN 60068-2-2:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu Próba B - suche gorąco – wytrzymałość PN-EN 60068-2-2:2009 Elementy i systemy automatyki, sygnalizacji pozarowej, instalacji elektrycznych, urzadzen elektrycznych i elektronicznych W tym miedzy innymi:  Centrala sterujaca urzadzeniami oddymiajacymi i przewietrzajacymi, sterownik wentylacji oddymiajacej  Centrala sterujaca urzadzeniami przeciwpozarowymi  Reczny przycisk oddymiania  Siec central sygnalizacji pozarowej  Systemy integrujace  Tablica sygnalizacji rownoleglej  Urzadzenia zasilajace w systemach automatyki pozarowej  Urzadzenie zdalnej sygnalizacji i obslugi  Wyniesiony mikrofon strazaka, konsola operatora systemu Proba B - suche goraco – wytrzymalosc PN-EN 60068-2-2:2009","categories":["electronics"],"row_index":1065,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console Test B - dry heat – endurance PN-EN 60068-2-2:2009","search_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台 PN-EN 60068-2-2:2009","test_object_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台"},{"_id":"6a5a55f19af9f73f3825133e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu","test_object_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console","methodology":"Próba B - suche gorąco – odporność","methodology_en":"Test B - dry heat – operational","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Próba B - suche gorąco – odporność","reference":"PN-EN 60068-2-2:2009","norm_bases":["PN-EN 60068-2-2:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu Próba B - suche gorąco – odporność PN-EN 60068-2-2:2009 Elementy i systemy automatyki, sygnalizacji pozarowej, instalacji elektrycznych, urzadzen elektrycznych i elektronicznych W tym miedzy innymi:  Centrala sterujaca urzadzeniami oddymiajacymi i przewietrzajacymi, sterownik wentylacji oddymiajacej  Centrala sterujaca urzadzeniami przeciwpozarowymi  Reczny przycisk oddymiania  Siec central sygnalizacji pozarowej  Systemy integrujace  Tablica sygnalizacji rownoleglej  Urzadzenia zasilajace w systemach automatyki pozarowej  Urzadzenie zdalnej sygnalizacji i obslugi  Wyniesiony mikrofon strazaka, konsola operatora systemu Proba B - suche goraco – odpornosc PN-EN 60068-2-2:2009","categories":["electronics"],"row_index":1066,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console Test B - dry heat – operational PN-EN 60068-2-2:2009","search_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台 PN-EN 60068-2-2:2009","test_object_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台"},{"_id":"6a5a55f19af9f73f3825133f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu","test_object_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console","methodology":"Próba Cab - wilgotne gorąco stałe – wytrzymałość","methodology_en":"Test Cab - damp heat, steady state – endurance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Próba Cab - wilgotne gorąco stałe – wytrzymałość","reference":"PN-EN 60068-2-78:2013-11","norm_bases":["PN-EN 60068-2-78:2013-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu Próba Cab - wilgotne gorąco stałe – wytrzymałość PN-EN 60068-2-78:2013-11 Elementy i systemy automatyki, sygnalizacji pozarowej, instalacji elektrycznych, urzadzen elektrycznych i elektronicznych W tym miedzy innymi:  Centrala sterujaca urzadzeniami oddymiajacymi i przewietrzajacymi, sterownik wentylacji oddymiajacej  Centrala sterujaca urzadzeniami przeciwpozarowymi  Reczny przycisk oddymiania  Siec central sygnalizacji pozarowej  Systemy integrujace  Tablica sygnalizacji rownoleglej  Urzadzenia zasilajace w systemach automatyki pozarowej  Urzadzenie zdalnej sygnalizacji i obslugi  Wyniesiony mikrofon strazaka, konsola operatora systemu Proba Cab - wilgotne goraco stale – wytrzymalosc PN-EN 60068-2-78:2013-11","categories":["electronics"],"row_index":1067,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console Test Cab - damp heat, steady state – endurance PN-EN 60068-2-78:2013-11","search_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台 PN-EN 60068-2-78:2013-11","test_object_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台"},{"_id":"6a5a55f19af9f73f38251340","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu","test_object_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console","methodology":"Próba Cab - wilgotne gorąco stałe- odporność","methodology_en":"Test Cab - damp heat, steady state - operational","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Próba Cab - wilgotne gorąco stałe- odporność","reference":"PN-EN 60068-2-78:2013-11","norm_bases":["PN-EN 60068-2-78:2013-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu Próba Cab - wilgotne gorąco stałe- odporność PN-EN 60068-2-78:2013-11 Elementy i systemy automatyki, sygnalizacji pozarowej, instalacji elektrycznych, urzadzen elektrycznych i elektronicznych W tym miedzy innymi:  Centrala sterujaca urzadzeniami oddymiajacymi i przewietrzajacymi, sterownik wentylacji oddymiajacej  Centrala sterujaca urzadzeniami przeciwpozarowymi  Reczny przycisk oddymiania  Siec central sygnalizacji pozarowej  Systemy integrujace  Tablica sygnalizacji rownoleglej  Urzadzenia zasilajace w systemach automatyki pozarowej  Urzadzenie zdalnej sygnalizacji i obslugi  Wyniesiony mikrofon strazaka, konsola operatora systemu Proba Cab - wilgotne goraco stale- odpornosc PN-EN 60068-2-78:2013-11","categories":["electronics"],"row_index":1068,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console Test Cab - damp heat, steady state - operational PN-EN 60068-2-78:2013-11","search_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台 PN-EN 60068-2-78:2013-11","test_object_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台"},{"_id":"6a5a55f19af9f73f38251341","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu","test_object_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console","methodology":"Stopnie ochrony zapewnianej przez obudowy (kod IP) Zakres do IP 46","methodology_en":"Degrees of protection provided by enclosures (IP code) Range up to IP 46","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stopnie ochrony zapewnianej przez obudowy (kod IP) Zakres do IP 46","reference":"PN-EN 60529:2003 PN-EN 60529:2003+AC:2017-12","norm_bases":["PN-EN 60529:2003 PN-EN 60529:2003+AC:2017-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu Stopnie ochrony zapewnianej przez obudowy (kod IP) Zakres do IP 46 PN-EN 60529:2003 PN-EN 60529:2003+AC:2017-12 Elementy i systemy automatyki, sygnalizacji pozarowej, instalacji elektrycznych, urzadzen elektrycznych i elektronicznych W tym miedzy innymi:  Centrala sterujaca urzadzeniami oddymiajacymi i przewietrzajacymi, sterownik wentylacji oddymiajacej  Centrala sterujaca urzadzeniami przeciwpozarowymi  Reczny przycisk oddymiania  Siec central sygnalizacji pozarowej  Systemy integrujace  Tablica sygnalizacji rownoleglej  Urzadzenia zasilajace w systemach automatyki pozarowej  Urzadzenie zdalnej sygnalizacji i obslugi  Wyniesiony mikrofon strazaka, konsola operatora systemu Stopnie ochrony zapewnianej przez obudowy (kod IP) Zakres do IP 46 PN-EN 60529:2003 PN-EN 60529:2003+AC:2017-12","categories":["electronics"],"row_index":1069,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console Degrees of protection provided by enclosures (IP code) Range up to IP 46 PN-EN 60529:2003 PN-EN 60529:2003+AC:2017-12","search_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台 PN-EN 60529:2003 PN-EN 60529:2003+AC:2017-12","test_object_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台"},{"_id":"6a5a55f19af9f73f38251342","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu","test_object_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console","methodology":"Próba Ea – udar pojedynczy (półsinusoida) (6 - 25) ms","methodology_en":"Test Ea – single shock (half-sine) (6 - 25) ms","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Próba Ea – udar pojedynczy (półsinusoida) (6 - 25) ms","reference":"EN 60068-2-27:2009","norm_bases":["EN 60068-2-27:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu Próba Ea – udar pojedynczy (półsinusoida) (6 - 25) ms EN 60068-2-27:2009 Elementy i systemy automatyki, sygnalizacji pozarowej, instalacji elektrycznych, urzadzen elektrycznych i elektronicznych W tym miedzy innymi:  Centrala sterujaca urzadzeniami oddymiajacymi i przewietrzajacymi, sterownik wentylacji oddymiajacej  Centrala sterujaca urzadzeniami przeciwpozarowymi  Reczny przycisk oddymiania  Siec central sygnalizacji pozarowej  Systemy integrujace  Tablica sygnalizacji rownoleglej  Urzadzenia zasilajace w systemach automatyki pozarowej  Urzadzenie zdalnej sygnalizacji i obslugi  Wyniesiony mikrofon strazaka, konsola operatora systemu Proba Ea – udar pojedynczy (polsinusoida) (6 - 25) ms EN 60068-2-27:2009","categories":["electronics"],"row_index":1070,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console Test Ea – single shock (half-sine) (6 - 25) ms EN 60068-2-27:2009","search_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台 EN 60068-2-27:2009","test_object_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台"},{"_id":"6a5a55f19af9f73f38251343","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu","test_object_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console","methodology":"Próba Eh - uderzenie (młot sprężynowy)","methodology_en":"Test Eh - impact (spring hammer)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Próba Eh - uderzenie (młot sprężynowy)","reference":"PN-EN 60068-2-75:2015-01","norm_bases":["PN-EN 60068-2-75:2015-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu Próba Eh - uderzenie (młot sprężynowy) PN-EN 60068-2-75:2015-01 Elementy i systemy automatyki, sygnalizacji pozarowej, instalacji elektrycznych, urzadzen elektrycznych i elektronicznych W tym miedzy innymi:  Centrala sterujaca urzadzeniami oddymiajacymi i przewietrzajacymi, sterownik wentylacji oddymiajacej  Centrala sterujaca urzadzeniami przeciwpozarowymi  Reczny przycisk oddymiania  Siec central sygnalizacji pozarowej  Systemy integrujace  Tablica sygnalizacji rownoleglej  Urzadzenia zasilajace w systemach automatyki pozarowej  Urzadzenie zdalnej sygnalizacji i obslugi  Wyniesiony mikrofon strazaka, konsola operatora systemu Proba Eh - uderzenie (mlot sprezynowy) PN-EN 60068-2-75:2015-01","categories":["electronics"],"row_index":1071,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console Test Eh - impact (spring hammer) PN-EN 60068-2-75:2015-01","search_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台 PN-EN 60068-2-75:2015-01","test_object_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台"},{"_id":"6a5a55f19af9f73f38251344","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu","test_object_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console","methodology":"Próba Fc – wibracje sinusoidalne","methodology_en":"Test Fc – sinusoidal vibration","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Próba Fc – wibracje sinusoidalne","reference":"PN-EN 60068-2-6:2008","norm_bases":["PN-EN 60068-2-6:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu Próba Fc – wibracje sinusoidalne PN-EN 60068-2-6:2008 Elementy i systemy automatyki, sygnalizacji pozarowej, instalacji elektrycznych, urzadzen elektrycznych i elektronicznych W tym miedzy innymi:  Centrala sterujaca urzadzeniami oddymiajacymi i przewietrzajacymi, sterownik wentylacji oddymiajacej  Centrala sterujaca urzadzeniami przeciwpozarowymi  Reczny przycisk oddymiania  Siec central sygnalizacji pozarowej  Systemy integrujace  Tablica sygnalizacji rownoleglej  Urzadzenia zasilajace w systemach automatyki pozarowej  Urzadzenie zdalnej sygnalizacji i obslugi  Wyniesiony mikrofon strazaka, konsola operatora systemu Proba Fc – wibracje sinusoidalne PN-EN 60068-2-6:2008","categories":["electronics"],"row_index":1072,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console Test Fc – sinusoidal vibration PN-EN 60068-2-6:2008","search_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台 PN-EN 60068-2-6:2008","test_object_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台"},{"_id":"6a5a55f19af9f73f38251345","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu","test_object_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console","methodology":"Zmiany napięcia sieciowego Zakres zmian napięcia: -15%, +10% Un","methodology_en":"Mains voltage variations Voltage variation range: -15%, +10% Un","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zmiany napięcia sieciowego Zakres zmian napięcia: -15%, +10% Un","reference":"PN-EN 50130-4:2012+ A1:2015-03","norm_bases":["PN-EN 50130-4:2012+ A1:2015-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy i systemy automatyki, sygnalizacji pożarowej, instalacji elektrycznych, urządzeń elektrycznych i elektronicznych W tym między innymi:  Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi, sterownik wentylacji oddymiającej  Centrala sterująca urządzeniami przeciwpożarowymi  Ręczny przycisk oddymiania  Sieć central sygnalizacji pożarowej  Systemy integrujące  Tablica sygnalizacji równoległej  Urządzenia zasilające w systemach automatyki pożarowej  Urządzenie zdalnej sygnalizacji i obsługi  Wyniesiony mikrofon strażaka, konsola operatora systemu Zmiany napięcia sieciowego Zakres zmian napięcia: -15%, +10% Un PN-EN 50130-4:2012+ A1:2015-03 Elementy i systemy automatyki, sygnalizacji pozarowej, instalacji elektrycznych, urzadzen elektrycznych i elektronicznych W tym miedzy innymi:  Centrala sterujaca urzadzeniami oddymiajacymi i przewietrzajacymi, sterownik wentylacji oddymiajacej  Centrala sterujaca urzadzeniami przeciwpozarowymi  Reczny przycisk oddymiania  Siec central sygnalizacji pozarowej  Systemy integrujace  Tablica sygnalizacji rownoleglej  Urzadzenia zasilajace w systemach automatyki pozarowej  Urzadzenie zdalnej sygnalizacji i obslugi  Wyniesiony mikrofon strazaka, konsola operatora systemu Zmiany napiecia sieciowego Zakres zmian napiecia: -15%, +10% Un PN-EN 50130-4:2012+ A1:2015-03","categories":["electronics"],"row_index":1073,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Components and systems of automation, fire alarm, electrical installations, electrical and electronic equipment Including among others:  Control panel for smoke and heat exhaust and ventilation devices, smoke exhaust ventilation controller  Control panel for fire protection devices  Manual smoke exhaust call point  Network of fire alarm control panels  Integrating systems  Parallel indication panel  Power supply equipment in fire automation systems  Remote indication and operating device  Remote firefighter's microphone, system operator console Mains voltage variations Voltage variation range: -15%, +10% Un PN-EN 50130-4:2012+ A1:2015-03","search_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台 PN-EN 50130-4:2012+ A1:2015-03","test_object_zh":"自动化、火灾报警、电气装置、电气与电子设备的元件与系统，其中包括：排烟与通风设备控制主机、排烟通风控制器、消防设备控制主机、手动排烟按钮、火灾报警主机网络、集成系统、并行信号显示盘、消防自动化系统供电装置、远程信号与操作装置、消防员遥控话筒与系统操作台"},{"_id":"6a5a55f19af9f73f38251346","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klapy dymowe","test_object_en":"Smoke vents","methodology":"Badanie klap dymowych w niskiej temperaturze otoczenia. Badanie kompletnej klapy dymowej.","methodology_en":"Testing of smoke vents at low ambient temperature. Testing of the complete smoke vent.","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Badanie klap dymowych w niskiej temperaturze otoczenia. Badanie kompletnej klapy dymowej.","reference":"PN-EN 12101-2:2005","norm_bases":["PN-EN 12101-2:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klapy dymowe Badanie klap dymowych w niskiej temperaturze otoczenia. Badanie kompletnej klapy dymowej. PN-EN 12101-2:2005 Klapy dymowe Badanie klap dymowych w niskiej temperaturze otoczenia. Badanie kompletnej klapy dymowej. PN-EN 12101-2:2005","categories":["other"],"row_index":1074,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Smoke vents Testing of smoke vents at low ambient temperature. Testing of the complete smoke vent. PN-EN 12101-2:2005"},{"_id":"6a5a55f19af9f73f38251347","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Izolatory zwarć","test_object_en":"Short-circuit isolators","methodology":"Cechy izolatora zwarć według Tablicy ZA.1 normy","methodology_en":"Features of the short-circuit isolator according to Table ZA.1 of the standard","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cechy izolatora zwarć według Tablicy ZA.1 normy","reference":"PN-EN 54-17:2007 w tym pkt 5.4 z wykorzystaniem PN EN 60068-2-2:2009 pkt 5.5. z wykorzystaniem PN EN 60068-2-1:2009 pkt 5.6 PN EN 60068-2-30:2008 pkt 5.7 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt 5.8 z wykorzystaniem PN-EN 60068-2-42:2004 pkt 5.9 z wykorzystaniem PN EN 60068-2-27:2009 pkt 5.11 i 5.12 z wykorzystaniem PN-EN 60068-2-6:2008 pkt. 5.13 z wykorzystaniem PN EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03","norm_bases":["PN-EN 54-17:2007 w tym pkt 5.4 z wykorzystaniem PN EN 60068-2-2:2009 pkt 5.5. z wykorzystaniem PN EN 60068-2-1:2009 pkt 5.6 PN EN 60068-2-30:2008 pkt 5.7 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt 5.8 z wykorzystaniem PN-EN 60068-2-42:2004 pkt 5.9 z wykorzystaniem PN EN 60068-2-27:2009 pkt 5.11 i 5.12 z wykorzystaniem PN-EN 60068-2-6:2008 pkt. 5.13 z wykorzystaniem PN EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Izolatory zwarć Cechy izolatora zwarć według Tablicy ZA.1 normy PN-EN 54-17:2007 w tym pkt 5.4 z wykorzystaniem PN EN 60068-2-2:2009 pkt 5.5. z wykorzystaniem PN EN 60068-2-1:2009 pkt 5.6 PN EN 60068-2-30:2008 pkt 5.7 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt 5.8 z wykorzystaniem PN-EN 60068-2-42:2004 pkt 5.9 z wykorzystaniem PN EN 60068-2-27:2009 pkt 5.11 i 5.12 z wykorzystaniem PN-EN 60068-2-6:2008 pkt. 5.13 z wykorzystaniem PN EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03 Izolatory zwarc Cechy izolatora zwarc wedlug Tablicy ZA.1 normy PN-EN 54-17:2007 w tym pkt 5.4 z wykorzystaniem PN EN 60068-2-2:2009 pkt 5.5. z wykorzystaniem PN EN 60068-2-1:2009 pkt 5.6 PN EN 60068-2-30:2008 pkt 5.7 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt 5.8 z wykorzystaniem PN-EN 60068-2-42:2004 pkt 5.9 z wykorzystaniem PN EN 60068-2-27:2009 pkt 5.11 i 5.12 z wykorzystaniem PN-EN 60068-2-6:2008 pkt. 5.13 z wykorzystaniem PN EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03","categories":["other"],"row_index":1075,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Short-circuit isolators Features of the short-circuit isolator according to Table ZA.1 of the standard PN-EN 54-17:2007 w tym pkt 5.4 z wykorzystaniem PN EN 60068-2-2:2009 pkt 5.5. z wykorzystaniem PN EN 60068-2-1:2009 pkt 5.6 PN EN 60068-2-30:2008 pkt 5.7 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt 5.8 z wykorzystaniem PN-EN 60068-2-42:2004 pkt 5.9 z wykorzystaniem PN EN 60068-2-27:2009 pkt 5.11 i 5.12 z wykorzystaniem PN-EN 60068-2-6:2008 pkt. 5.13 z wykorzystaniem PN EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03"},{"_id":"6a5a55f19af9f73f38251348","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Ręczny ostrzegacz pożarowy","test_object_en":"Manual call point","methodology":"Cechy ręcznego ostrzegacza pożarowego według Tablicy ZA.1 normy","methodology_en":"Features of the manual call point according to Table ZA.1 of the standard","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cechy ręcznego ostrzegacza pożarowego według Tablicy ZA.1 normy","reference":"PN-EN 54-11:2004 +A1:2006 w tym pkt. 4.4.1. z wykorzystaniem PN EN 894-3:2002 PN EN 894-3+A1:2010 pkt. 5.7. i 5.8 z wykorzystaniem PN-EN 60068-2-2:2009 pkt. 5.9 z wykorzystaniem PN EN 60068-2-1: 2009 pkt 5.10 | PN-EN 60068-2-30:2008 pkt 5.12 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt 5.13 z wykorzystaniem PN-EN 60068-2-42:2004 pkt 5.14 z wykorzystaniem PN-EN 60068-2-27:2009 pkt 5.16. i 5.17. z wykorzystaniem PN EN 60068-2-6:2002 pkt 5.18 z wykorzystaniem PN EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03","norm_bases":["PN-EN 54-11:2004 +A1:2006 w tym pkt. 4.4.1. z wykorzystaniem PN EN 894-3:2002 PN EN 894-3+A1:2010 pkt. 5.7. i 5.8 z wykorzystaniem PN-EN 60068-2-2:2009 pkt. 5.9 z wykorzystaniem PN EN 60068-2-1: 2009 pkt 5.10","PN-EN 60068-2-30:2008 pkt 5.12 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt 5.13 z wykorzystaniem PN-EN 60068-2-42:2004 pkt 5.14 z wykorzystaniem PN-EN 60068-2-27:2009 pkt 5.16. i 5.17. z wykorzystaniem PN EN 60068-2-6:2002 pkt 5.18 z wykorzystaniem PN EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ręczny ostrzegacz pożarowy Cechy ręcznego ostrzegacza pożarowego według Tablicy ZA.1 normy PN-EN 54-11:2004 +A1:2006 w tym pkt. 4.4.1. z wykorzystaniem PN EN 894-3:2002 PN EN 894-3+A1:2010 pkt. 5.7. i 5.8 z wykorzystaniem PN-EN 60068-2-2:2009 pkt. 5.9 z wykorzystaniem PN EN 60068-2-1: 2009 pkt 5.10 | PN-EN 60068-2-30:2008 pkt 5.12 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt 5.13 z wykorzystaniem PN-EN 60068-2-42:2004 pkt 5.14 z wykorzystaniem PN-EN 60068-2-27:2009 pkt 5.16. i 5.17. z wykorzystaniem PN EN 60068-2-6:2002 pkt 5.18 z wykorzystaniem PN EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03 Reczny ostrzegacz pozarowy Cechy recznego ostrzegacza pozarowego wedlug Tablicy ZA.1 normy PN-EN 54-11:2004 +A1:2006 w tym pkt. 4.4.1. z wykorzystaniem PN EN 894-3:2002 PN EN 894-3+A1:2010 pkt. 5.7. i 5.8 z wykorzystaniem PN-EN 60068-2-2:2009 pkt. 5.9 z wykorzystaniem PN EN 60068-2-1: 2009 pkt 5.10 | PN-EN 60068-2-30:2008 pkt 5.12 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt 5.13 z wykorzystaniem PN-EN 60068-2-42:2004 pkt 5.14 z wykorzystaniem PN-EN 60068-2-27:2009 pkt 5.16. i 5.17. z wykorzystaniem PN EN 60068-2-6:2002 pkt 5.18 z wykorzystaniem PN EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03","categories":["other"],"row_index":1076,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Manual call point Features of the manual call point according to Table ZA.1 of the standard PN-EN 54-11:2004 +A1:2006 w tym pkt. 4.4.1. z wykorzystaniem PN EN 894-3:2002 PN EN 894-3+A1:2010 pkt. 5.7. i 5.8 z wykorzystaniem PN-EN 60068-2-2:2009 pkt. 5.9 z wykorzystaniem PN EN 60068-2-1: 2009 pkt 5.10 | PN-EN 60068-2-30:2008 pkt 5.12 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt 5.13 z wykorzystaniem PN-EN 60068-2-42:2004 pkt 5.14 z wykorzystaniem PN-EN 60068-2-27:2009 pkt 5.16. i 5.17. z wykorzystaniem PN EN 60068-2-6:2002 pkt 5.18 z wykorzystaniem PN EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03"},{"_id":"6a5a55f19af9f73f38251349","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Urządzenia i systemy transmisji alarmu","test_object_en":"Alarm transmission equipment and systems","methodology":"Cechy urządzenia i systemu transmisji alarmu według Tablicy ZA.1 normy","methodology_en":"Features of the alarm transmission equipment and system according to Table ZA.1 of the standard","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cechy urządzenia i systemu transmisji alarmu według Tablicy ZA.1 normy","reference":"PN-EN 54-21:2009 W tym: pkt. 7.3 z wykorzystaniem PN-EN 60529:2003 pkt. 7.6 z wykorzystaniem PN EN 54-2:2002 +A1:2007 pkt. 9 z wykorzystaniem PN-EN 54-4:2001 + A1:2004 + A2:2007 pkt. 10.4 z wykorzystaniem PN EN 60068-2-1:2009 pkt. 10.5 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt. 10.6 z wykorzystaniem PN-EN 60068-2-75:2015-01 pkt. 10.7 z wykorzystaniem PN-EN 60068-2-6:2008 pkt. 10.8 z wykorzystaniem PN EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03 pkt.10.9 z wykorzystaniem PN-EN 54-4:2001 + A1:2004 + A2:2007 pkt.10.10 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt.10.11 z wykorzystaniem PN-EN 60068-2-6:2008","norm_bases":["PN-EN 54-21:2009 W tym: pkt. 7.3 z wykorzystaniem PN-EN 60529:2003 pkt. 7.6 z wykorzystaniem PN EN 54-2:2002 +A1:2007 pkt. 9 z wykorzystaniem PN-EN 54-4:2001 + A1:2004 + A2:2007 pkt. 10.4 z wykorzystaniem PN EN 60068-2-1:2009 pkt. 10.5 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt. 10.6 z wykorzystaniem PN-EN 60068-2-75:2015-01 pkt. 10.7 z wykorzystaniem PN-EN 60068-2-6:2008 pkt. 10.8 z wykorzystaniem PN EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03 pkt.10.9 z wykorzystaniem PN-EN 54-4:2001 + A1:2004 + A2:2007 pkt.10.10 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt.10.11 z wykorzystaniem PN-EN 60068-2-6:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia i systemy transmisji alarmu Cechy urządzenia i systemu transmisji alarmu według Tablicy ZA.1 normy PN-EN 54-21:2009 W tym: pkt. 7.3 z wykorzystaniem PN-EN 60529:2003 pkt. 7.6 z wykorzystaniem PN EN 54-2:2002 +A1:2007 pkt. 9 z wykorzystaniem PN-EN 54-4:2001 + A1:2004 + A2:2007 pkt. 10.4 z wykorzystaniem PN EN 60068-2-1:2009 pkt. 10.5 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt. 10.6 z wykorzystaniem PN-EN 60068-2-75:2015-01 pkt. 10.7 z wykorzystaniem PN-EN 60068-2-6:2008 pkt. 10.8 z wykorzystaniem PN EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03 pkt.10.9 z wykorzystaniem PN-EN 54-4:2001 + A1:2004 + A2:2007 pkt.10.10 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt.10.11 z wykorzystaniem PN-EN 60068-2-6:2008 Urzadzenia i systemy transmisji alarmu Cechy urzadzenia i systemu transmisji alarmu wedlug Tablicy ZA.1 normy PN-EN 54-21:2009 W tym: pkt. 7.3 z wykorzystaniem PN-EN 60529:2003 pkt. 7.6 z wykorzystaniem PN EN 54-2:2002 +A1:2007 pkt. 9 z wykorzystaniem PN-EN 54-4:2001 + A1:2004 + A2:2007 pkt. 10.4 z wykorzystaniem PN EN 60068-2-1:2009 pkt. 10.5 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt. 10.6 z wykorzystaniem PN-EN 60068-2-75:2015-01 pkt. 10.7 z wykorzystaniem PN-EN 60068-2-6:2008 pkt. 10.8 z wykorzystaniem PN EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03 pkt.10.9 z wykorzystaniem PN-EN 54-4:2001 + A1:2004 + A2:2007 pkt.10.10 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt.10.11 z wykorzystaniem PN-EN 60068-2-6:2008","categories":["other"],"row_index":1077,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Alarm transmission equipment and systems Features of the alarm transmission equipment and system according to Table ZA.1 of the standard PN-EN 54-21:2009 W tym: pkt. 7.3 z wykorzystaniem PN-EN 60529:2003 pkt. 7.6 z wykorzystaniem PN EN 54-2:2002 +A1:2007 pkt. 9 z wykorzystaniem PN-EN 54-4:2001 + A1:2004 + A2:2007 pkt. 10.4 z wykorzystaniem PN EN 60068-2-1:2009 pkt. 10.5 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt. 10.6 z wykorzystaniem PN-EN 60068-2-75:2015-01 pkt. 10.7 z wykorzystaniem PN-EN 60068-2-6:2008 pkt. 10.8 z wykorzystaniem PN EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03 pkt.10.9 z wykorzystaniem PN-EN 54-4:2001 + A1:2004 + A2:2007 pkt.10.10 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt.10.11 z wykorzystaniem PN-EN 60068-2-6:2008"},{"_id":"6a5a55f19af9f73f3825134a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Urządzenia wejścia/wyjścia","test_object_en":"Input/output devices","methodology":"Cechy urządzenia wejścia/wyjścia według Tablicy ZA.1 normy","methodology_en":"Features of the input/output device according to Table ZA.1 of the standard","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cechy urządzenia wejścia/wyjścia według Tablicy ZA.1 normy","reference":"PN-EN 54-18:2007+ AC:2007 PN-EN 12101-10:2007 +AC :2007 W tym : pkt 5.3 z wykorzystaniem PN-EN 60068-2-2:2009 pkt 5.4 z wykorzystaniem PN-EN 60068-2-1:2009 pkt 5.5 z wykorzystaniem PN-EN 60068-2-30:2008 pkt 5.6 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt 5.7 z wykorzystaniem PN-EN 60068-2-42:2004 pkt.5.8 z wykorzystaniem PN-EN 60068-2-27:2009 pkt. 5.9 z wykorzystaniem PN-EN 60068-2-75:2015-01 pkt 5.10 i 5.11 z wykorzystaniem PN-EN 60068-2-6:2008 pkt. 5.12 z wykorzystaniem PN EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03","norm_bases":["PN-EN 54-18:2007+ AC:2007 PN-EN 12101-10:2007 +AC :2007 W tym : pkt 5.3 z wykorzystaniem PN-EN 60068-2-2:2009 pkt 5.4 z wykorzystaniem PN-EN 60068-2-1:2009 pkt 5.5 z wykorzystaniem PN-EN 60068-2-30:2008 pkt 5.6 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt 5.7 z wykorzystaniem PN-EN 60068-2-42:2004 pkt.5.8 z wykorzystaniem PN-EN 60068-2-27:2009 pkt. 5.9 z wykorzystaniem PN-EN 60068-2-75:2015-01 pkt 5.10 i 5.11 z wykorzystaniem PN-EN 60068-2-6:2008 pkt. 5.12 z wykorzystaniem PN EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia wejścia/wyjścia Cechy urządzenia wejścia/wyjścia według Tablicy ZA.1 normy PN-EN 54-18:2007+ AC:2007 PN-EN 12101-10:2007 +AC :2007 W tym : pkt 5.3 z wykorzystaniem PN-EN 60068-2-2:2009 pkt 5.4 z wykorzystaniem PN-EN 60068-2-1:2009 pkt 5.5 z wykorzystaniem PN-EN 60068-2-30:2008 pkt 5.6 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt 5.7 z wykorzystaniem PN-EN 60068-2-42:2004 pkt.5.8 z wykorzystaniem PN-EN 60068-2-27:2009 pkt. 5.9 z wykorzystaniem PN-EN 60068-2-75:2015-01 pkt 5.10 i 5.11 z wykorzystaniem PN-EN 60068-2-6:2008 pkt. 5.12 z wykorzystaniem PN EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03 Urzadzenia wejscia/wyjscia Cechy urzadzenia wejscia/wyjscia wedlug Tablicy ZA.1 normy PN-EN 54-18:2007+ AC:2007 PN-EN 12101-10:2007 +AC :2007 W tym : pkt 5.3 z wykorzystaniem PN-EN 60068-2-2:2009 pkt 5.4 z wykorzystaniem PN-EN 60068-2-1:2009 pkt 5.5 z wykorzystaniem PN-EN 60068-2-30:2008 pkt 5.6 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt 5.7 z wykorzystaniem PN-EN 60068-2-42:2004 pkt.5.8 z wykorzystaniem PN-EN 60068-2-27:2009 pkt. 5.9 z wykorzystaniem PN-EN 60068-2-75:2015-01 pkt 5.10 i 5.11 z wykorzystaniem PN-EN 60068-2-6:2008 pkt. 5.12 z wykorzystaniem PN EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03","categories":["other"],"row_index":1078,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Input/output devices Features of the input/output device according to Table ZA.1 of the standard PN-EN 54-18:2007+ AC:2007 PN-EN 12101-10:2007 +AC :2007 W tym : pkt 5.3 z wykorzystaniem PN-EN 60068-2-2:2009 pkt 5.4 z wykorzystaniem PN-EN 60068-2-1:2009 pkt 5.5 z wykorzystaniem PN-EN 60068-2-30:2008 pkt 5.6 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt 5.7 z wykorzystaniem PN-EN 60068-2-42:2004 pkt.5.8 z wykorzystaniem PN-EN 60068-2-27:2009 pkt. 5.9 z wykorzystaniem PN-EN 60068-2-75:2015-01 pkt 5.10 i 5.11 z wykorzystaniem PN-EN 60068-2-6:2008 pkt. 5.12 z wykorzystaniem PN EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03"},{"_id":"6a5a55f19af9f73f3825134b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zasilacz","test_object_en":"Power supply","methodology":"Cechy zasilacza według pkt normy 11, 12.1 , 12.3.1, 12.4, 12.5, 12.6, 12.7, 12.8, 12.9, 12.10,12.13 , 12.14, 12.15 oraz Tablicy ZA.1","methodology_en":"Features of the power supply equipment according to clauses 11, 12.1 , 12.3.1, 12.4, 12.5, 12.6, 12.7, 12.8, 12.9, 12.10,12.13 , 12.14, 12.15 of the standard and Table ZA.1","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cechy zasilacza według pkt normy 11, 12.1 , 12.3.1, 12.4, 12.5, 12.6, 12.7, 12.8, 12.9, 12.10,12.13 , 12.14, 12.15 oraz Tablicy ZA.1","reference":"PN-EN 12101-10:2007 +AC :2007 w tym pkt. 12.4 z wykorzystaniem PN-EN 60068-2-1:2009 pkt 12.5 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt. 12.6 z wykorzystaniem PN-EN 60068-2-75:2015-01 pkt.12.7 i 12.9 z wykorzystaniem PN-EN 60068-2-6:2008 pkt.12.8. z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt 12.10. z wykorzystaniem PN-EN 60068-2-2:2009 pkt 12.13 i 12.14 z wykorzystaniem PN-EN 60529:2003 pkt 12.15 z wykorzystaniem PN EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03","norm_bases":["PN-EN 12101-10:2007 +AC :2007 w tym pkt. 12.4 z wykorzystaniem PN-EN 60068-2-1:2009 pkt 12.5 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt. 12.6 z wykorzystaniem PN-EN 60068-2-75:2015-01 pkt.12.7 i 12.9 z wykorzystaniem PN-EN 60068-2-6:2008 pkt.12.8. z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt 12.10. z wykorzystaniem PN-EN 60068-2-2:2009 pkt 12.13 i 12.14 z wykorzystaniem PN-EN 60529:2003 pkt 12.15 z wykorzystaniem PN EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zasilacz Cechy zasilacza według pkt normy 11, 12.1 , 12.3.1, 12.4, 12.5, 12.6, 12.7, 12.8, 12.9, 12.10,12.13 , 12.14, 12.15 oraz Tablicy ZA.1 PN-EN 12101-10:2007 +AC :2007 w tym pkt. 12.4 z wykorzystaniem PN-EN 60068-2-1:2009 pkt 12.5 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt. 12.6 z wykorzystaniem PN-EN 60068-2-75:2015-01 pkt.12.7 i 12.9 z wykorzystaniem PN-EN 60068-2-6:2008 pkt.12.8. z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt 12.10. z wykorzystaniem PN-EN 60068-2-2:2009 pkt 12.13 i 12.14 z wykorzystaniem PN-EN 60529:2003 pkt 12.15 z wykorzystaniem PN EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03 Zasilacz Cechy zasilacza wedlug pkt normy 11, 12.1 , 12.3.1, 12.4, 12.5, 12.6, 12.7, 12.8, 12.9, 12.10,12.13 , 12.14, 12.15 oraz Tablicy ZA.1 PN-EN 12101-10:2007 +AC :2007 w tym pkt. 12.4 z wykorzystaniem PN-EN 60068-2-1:2009 pkt 12.5 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt. 12.6 z wykorzystaniem PN-EN 60068-2-75:2015-01 pkt.12.7 i 12.9 z wykorzystaniem PN-EN 60068-2-6:2008 pkt.12.8. z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt 12.10. z wykorzystaniem PN-EN 60068-2-2:2009 pkt 12.13 i 12.14 z wykorzystaniem PN-EN 60529:2003 pkt 12.15 z wykorzystaniem PN EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03","categories":["other"],"row_index":1079,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Power supply Features of the power supply equipment according to clauses 11, 12.1 , 12.3.1, 12.4, 12.5, 12.6, 12.7, 12.8, 12.9, 12.10,12.13 , 12.14, 12.15 of the standard and Table ZA.1 PN-EN 12101-10:2007 +AC :2007 w tym pkt. 12.4 z wykorzystaniem PN-EN 60068-2-1:2009 pkt 12.5 z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt. 12.6 z wykorzystaniem PN-EN 60068-2-75:2015-01 pkt.12.7 i 12.9 z wykorzystaniem PN-EN 60068-2-6:2008 pkt.12.8. z wykorzystaniem PN-EN 60068-2-78:2013-11 pkt 12.10. z wykorzystaniem PN-EN 60068-2-2:2009 pkt 12.13 i 12.14 z wykorzystaniem PN-EN 60529:2003 pkt 12.15 z wykorzystaniem PN EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03"},{"_id":"6a5a55f19af9f73f3825134c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zasilacz","test_object_en":"Power supply","methodology":"Cechy zasilacza według Tablicy ZA.1 normy","methodology_en":"Features of the power supply equipment according to Table ZA.1 of the standard","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cechy zasilacza według Tablicy ZA.1 normy","reference":"PN-EN 54-4:2001 + A1:2004 + A2:2007 W tym Pkt 9.5 z wykorzystaniem PN-EN 60068-2-1:2009 Pkt 9.6 i 9.14 z wykorzystaniem PN-EN 60068-2-78:2013-11 Pkt 9.7 z wykorzystaniem PN-EN 60068-2-75:2015-01 Pkt 9.8 i 9.15 z wykorzystaniem PN-EN 60068-2-6:2008 Pkt 9.9 z zastosowaniem PN EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03","norm_bases":["PN-EN 54-4:2001 + A1:2004 + A2:2007 W tym Pkt 9.5 z wykorzystaniem PN-EN 60068-2-1:2009 Pkt 9.6 i 9.14 z wykorzystaniem PN-EN 60068-2-78:2013-11 Pkt 9.7 z wykorzystaniem PN-EN 60068-2-75:2015-01 Pkt 9.8 i 9.15 z wykorzystaniem PN-EN 60068-2-6:2008 Pkt 9.9 z zastosowaniem PN EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zasilacz Cechy zasilacza według Tablicy ZA.1 normy PN-EN 54-4:2001 + A1:2004 + A2:2007 W tym Pkt 9.5 z wykorzystaniem PN-EN 60068-2-1:2009 Pkt 9.6 i 9.14 z wykorzystaniem PN-EN 60068-2-78:2013-11 Pkt 9.7 z wykorzystaniem PN-EN 60068-2-75:2015-01 Pkt 9.8 i 9.15 z wykorzystaniem PN-EN 60068-2-6:2008 Pkt 9.9 z zastosowaniem PN EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03 Zasilacz Cechy zasilacza wedlug Tablicy ZA.1 normy PN-EN 54-4:2001 + A1:2004 + A2:2007 W tym Pkt 9.5 z wykorzystaniem PN-EN 60068-2-1:2009 Pkt 9.6 i 9.14 z wykorzystaniem PN-EN 60068-2-78:2013-11 Pkt 9.7 z wykorzystaniem PN-EN 60068-2-75:2015-01 Pkt 9.8 i 9.15 z wykorzystaniem PN-EN 60068-2-6:2008 Pkt 9.9 z zastosowaniem PN EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03","categories":["other"],"row_index":1080,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Power supply Features of the power supply equipment according to Table ZA.1 of the standard PN-EN 54-4:2001 + A1:2004 + A2:2007 W tym Pkt 9.5 z wykorzystaniem PN-EN 60068-2-1:2009 Pkt 9.6 i 9.14 z wykorzystaniem PN-EN 60068-2-78:2013-11 Pkt 9.7 z wykorzystaniem PN-EN 60068-2-75:2015-01 Pkt 9.8 i 9.15 z wykorzystaniem PN-EN 60068-2-6:2008 Pkt 9.9 z zastosowaniem PN EN 50130-4:2002 + A2:2007 PN-EN 50130-4:2012+A1:2015-03"},{"_id":"6a5a55f19af9f73f3825134d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Dachy","test_object_en":"Roofs","methodology":"Odporność dachów na ogień zewnętrzny - zasięg i rodzaj zniszczenia - rozprzestrzenienie płomienia - płonące krople - penetracja","methodology_en":"Resistance of roofs to external fire - extent and type of damage - flame spread - burning droplets - penetration","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność dachów na ogień zewnętrzny - zasięg i rodzaj zniszczenia - rozprzestrzenienie płomienia - płonące krople - penetracja","reference":"PN-ENV 1187:2004 „N” Metoda 1","norm_bases":["PN-ENV 1187:2004 „N” Metoda 1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Dachy Odporność dachów na ogień zewnętrzny - zasięg i rodzaj zniszczenia - rozprzestrzenienie płomienia - płonące krople - penetracja PN-ENV 1187:2004 „N” Metoda 1 Dachy Odpornosc dachow na ogien zewnetrzny - zasieg i rodzaj zniszczenia - rozprzestrzenienie plomienia - plonace krople - penetracja PN-ENV 1187:2004 „N” Metoda 1","categories":["construction"],"row_index":1081,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Roofs Resistance of roofs to external fire - extent and type of damage - flame spread - burning droplets - penetration PN-ENV 1187:2004 „N” Metoda 1"},{"_id":"6a5a55f19af9f73f3825134e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drogowe urządzenia przeciwhałasowe","test_object_en":"Road traffic noise reducing devices","methodology":"Odporność na pożar zarośli - zasięg i rodzaj zniszczenia - rozprzestrzenienie płomienia","methodology_en":"Resistance to brushwood fire - extent and type of damage - flame spread","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na pożar zarośli - zasięg i rodzaj zniszczenia - rozprzestrzenienie płomienia","reference":"PN-EN 1794-2:2011 Załącznik A","norm_bases":["PN-EN 1794-2:2011 Załącznik A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drogowe urządzenia przeciwhałasowe Odporność na pożar zarośli - zasięg i rodzaj zniszczenia - rozprzestrzenienie płomienia PN-EN 1794-2:2011 Załącznik A Drogowe urzadzenia przeciwhalasowe Odpornosc na pozar zarosli - zasieg i rodzaj zniszczenia - rozprzestrzenienie plomienia PN-EN 1794-2:2011 Zalacznik A","categories":["other"],"row_index":1082,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Road traffic noise reducing devices Resistance to brushwood fire - extent and type of damage - flame spread PN-EN 1794-2:2011 Załącznik A"},{"_id":"6a5a55f19af9f73f3825134f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kable i przewody elektryczne","test_object_en":"Electric cables and wires","methodology":"Badanie odporności na ogień kabli i przewodów bez ochrony specjalnej (klasyfikacja P)","methodology_en":"Fire resistance testing of cables and wires without special protection (classification P)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Badanie odporności na ogień kabli i przewodów bez ochrony specjalnej (klasyfikacja P)","reference":"PN-EN 50577:2016-02","norm_bases":["PN-EN 50577:2016-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i przewody elektryczne Badanie odporności na ogień kabli i przewodów bez ochrony specjalnej (klasyfikacja P) PN-EN 50577:2016-02 Kable i przewody elektryczne Badanie odpornosci na ogien kabli i przewodow bez ochrony specjalnej (klasyfikacja P) PN-EN 50577:2016-02","categories":["other"],"row_index":1083,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electric cables and wires Fire resistance testing of cables and wires without special protection (classification P) PN-EN 50577:2016-02"},{"_id":"6a5a55f19af9f73f38251350","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klapy dymowe","test_object_en":"Smoke vents","methodology":"Skuteczność działania klap dymowych - powierzchnia czynna","methodology_en":"Operational effectiveness of smoke vents - aerodynamic free area","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność działania klap dymowych - powierzchnia czynna","reference":"PN-EN 12101-2 :2017 PN-EN 12101-2 :2005","norm_bases":["PN-EN 12101-2 :2017 PN-EN 12101-2 :2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klapy dymowe Skuteczność działania klap dymowych - powierzchnia czynna PN-EN 12101-2 :2017 PN-EN 12101-2 :2005 Klapy dymowe Skutecznosc dzialania klap dymowych - powierzchnia czynna PN-EN 12101-2 :2017 PN-EN 12101-2 :2005","categories":["other"],"row_index":1084,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Smoke vents Operational effectiveness of smoke vents - aerodynamic free area PN-EN 12101-2 :2017 PN-EN 12101-2 :2005"},{"_id":"6a5a55f19af9f73f38251351","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kratki wentylacyjne","test_object_en":"Ventilation grilles","methodology":"Odporność ogniowa","methodology_en":"Fire resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność ogniowa","reference":"PN-EN 1364-5:2017-08","norm_bases":["PN-EN 1364-5:2017-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kratki wentylacyjne Odporność ogniowa PN-EN 1364-5:2017-08 Kratki wentylacyjne Odpornosc ogniowa PN-EN 1364-5:2017-08","categories":["other"],"row_index":1085,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ventilation grilles Fire resistance PN-EN 1364-5:2017-08","methodology_zh":"耐火性","search_zh":"耐火性 PN-EN 1364-5:2017-08"},{"_id":"6a5a55f19af9f73f38251352","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Systemy zabezpieczeń ogniochronnych belek stalowych z otworami w środniku","test_object_en":"Fire protection systems for steel beams with web openings","methodology":"Skuteczność ogniochronna zabezpieczenia ogniochronnego elementów stalowych – czas osiągnięcia temperatury","methodology_en":"Fire protection effectiveness of the fire protection of steel elements – time to reach the temperature","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność ogniochronna zabezpieczenia ogniochronnego elementów stalowych – czas osiągnięcia temperatury","reference":"PN-EN 13381-9:2015-08","norm_bases":["PN-EN 13381-9:2015-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Systemy zabezpieczeń ogniochronnych belek stalowych z otworami w środniku Skuteczność ogniochronna zabezpieczenia ogniochronnego elementów stalowych – czas osiągnięcia temperatury PN-EN 13381-9:2015-08 Systemy zabezpieczen ogniochronnych belek stalowych z otworami w srodniku Skutecznosc ogniochronna zabezpieczenia ogniochronnego elementow stalowych – czas osiagniecia temperatury PN-EN 13381-9:2015-08","categories":["materials"],"row_index":1086,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fire protection systems for steel beams with web openings Fire protection effectiveness of the fire protection of steel elements – time to reach the temperature PN-EN 13381-9:2015-08"},{"_id":"6a5a55f19af9f73f38251353","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Uszczelnienia złączy liniowych","test_object_en":"Seals for linear joints","methodology":"Szczelność ogniowa, izolacyjność ogniowa - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury maksymalnej - zdolność przemieszczania","methodology_en":"Fire integrity, fire insulation - sustained flaming - openings and cracks - ignition of the cotton wool pad - maximum temperature rise - displacement capability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność ogniowa, izolacyjność ogniowa - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury maksymalnej - zdolność przemieszczania","reference":"PN-EN 15882-4:2012E „N”","norm_bases":["PN-EN 15882-4:2012E „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Uszczelnienia złączy liniowych Szczelność ogniowa, izolacyjność ogniowa - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury maksymalnej - zdolność przemieszczania PN-EN 15882-4:2012E „N” Uszczelnienia zlaczy liniowych Szczelnosc ogniowa, izolacyjnosc ogniowa - utrzymywanie sie plomienia - otwory i pekniecia - zapalenie tamponu z waty bawelnianej - przyrost temperatury maksymalnej - zdolnosc przemieszczania PN-EN 15882-4:2012E „N”","categories":["construction"],"row_index":1087,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Seals for linear joints Fire integrity, fire insulation - sustained flaming - openings and cracks - ignition of the cotton wool pad - maximum temperature rise - displacement capability PN-EN 15882-4:2012E „N”"},{"_id":"6a5a55f19af9f73f38251354","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby budowlane","test_object_en":"Construction products","methodology":"Tlenie","methodology_en":"Smouldering","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Tlenie","reference":"PN-EN 16733:2016-06","norm_bases":["PN-EN 16733:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby budowlane Tlenie PN-EN 16733:2016-06 Wyroby budowlane Tlenie PN-EN 16733:2016-06","categories":["construction"],"row_index":1088,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Construction products Smouldering PN-EN 16733:2016-06"},{"_id":"6a5a55f19af9f73f38251355","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby budowlane, konstrukcyjne i wykończeniowe","test_object_en":"Construction, structural and finishing products","methodology":"Toksyczność produktów rozkładu i spalania - oznaczenie stężeń i emisji masowej (CO, CO , HCN, HCl, NH i SO ) 2 3 2 - wskaźniki toksymetryczne","methodology_en":"Toxicity of decomposition and combustion products - determination of concentrations and mass emission (CO, CO , HCN, HCl, NH and SO ) 2 3 2 - toxicometric indices","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Toksyczność produktów rozkładu i spalania - oznaczenie stężeń i emisji masowej (CO, CO , HCN, HCl, NH i SO ) 2 3 2 - wskaźniki toksymetryczne","reference":"PN-88/B-02855","norm_bases":["PN-88/B-02855"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby budowlane, konstrukcyjne i wykończeniowe Toksyczność produktów rozkładu i spalania - oznaczenie stężeń i emisji masowej (CO, CO , HCN, HCl, NH i SO ) 2 3 2 - wskaźniki toksymetryczne PN-88/B-02855 Wyroby budowlane, konstrukcyjne i wykonczeniowe Toksycznosc produktow rozkladu i spalania - oznaczenie stezen i emisji masowej (CO, CO , HCN, HCl, NH i SO ) 2 3 2 - wskazniki toksymetryczne PN-88/B-02855","categories":["environment","construction"],"row_index":1089,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Construction, structural and finishing products Toxicity of decomposition and combustion products - determination of concentrations and mass emission (CO, CO , HCN, HCl, NH and SO ) 2 3 2 - toxicometric indices PN-88/B-02855"},{"_id":"6a5a55f19af9f73f38251356","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Balkony E","test_object_en":"Balconies E","methodology":"Nośność ogniowa R - maksymalne obciążenie 400T - deformacja - prędkość deformacji","methodology_en":"Fire load-bearing capacity R - maximum load 400T - deformation - rate of deformation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność ogniowa R - maksymalne obciążenie 400T - deformacja - prędkość deformacji","reference":"PN-EN 1365-5 PN-EN 1363-1 „N” PN-EN 1363-2 „N”","norm_bases":["PN-EN 1365-5 PN-EN 1363-1 „N” PN-EN 1363-2 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Balkony E Nośność ogniowa R - maksymalne obciążenie 400T - deformacja - prędkość deformacji PN-EN 1365-5 PN-EN 1363-1 „N” PN-EN 1363-2 „N” Balkony E Nosnosc ogniowa R - maksymalne obciazenie 400T - deformacja - predkosc deformacji PN-EN 1365-5 PN-EN 1363-1 „N” PN-EN 1363-2 „N”","categories":["other"],"row_index":1090,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Balconies E Fire load-bearing capacity R - maximum load 400T - deformation - rate of deformation PN-EN 1365-5 PN-EN 1363-1 „N” PN-EN 1363-2 „N”"},{"_id":"6a5a55f19af9f73f38251357","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Belki E","test_object_en":"Beams E","methodology":"Nośność ogniowa R - maksymalne obciążenie 400T - deformacja - prędkość deformacji","methodology_en":"Fire load-bearing capacity R - maximum load 400T - deformation - rate of deformation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność ogniowa R - maksymalne obciążenie 400T - deformacja - prędkość deformacji","reference":"PN-EN 1365-3 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”","norm_bases":["PN-EN 1365-3 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Belki E Nośność ogniowa R - maksymalne obciążenie 400T - deformacja - prędkość deformacji PN-EN 1365-3 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” Belki E Nosnosc ogniowa R - maksymalne obciazenie 400T - deformacja - predkosc deformacji PN-EN 1365-3 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”","categories":["other"],"row_index":1091,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Beams E Fire load-bearing capacity R - maximum load 400T - deformation - rate of deformation PN-EN 1365-3 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”"},{"_id":"6a5a55f19af9f73f38251358","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Dachy E","test_object_en":"Roofs E","methodology":"Odporność dachów na ogień zewnętrzny - zasięg i rodzaj zniszczenia - rozprzestrzenienie płomienia - płonące krople - penetracja","methodology_en":"Resistance of roofs to external fire - extent and type of damage - flame spread - burning droplets - penetration","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność dachów na ogień zewnętrzny - zasięg i rodzaj zniszczenia - rozprzestrzenienie płomienia - płonące krople - penetracja","reference":"EN/TS 1187 „N” Metoda 1","norm_bases":["EN/TS 1187 „N” Metoda 1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Dachy E Odporność dachów na ogień zewnętrzny - zasięg i rodzaj zniszczenia - rozprzestrzenienie płomienia - płonące krople - penetracja EN/TS 1187 „N” Metoda 1 Dachy E Odpornosc dachow na ogien zewnetrzny - zasieg i rodzaj zniszczenia - rozprzestrzenienie plomienia - plonace krople - penetracja EN/TS 1187 „N” Metoda 1","categories":["construction"],"row_index":1092,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Roofs E Resistance of roofs to external fire - extent and type of damage - flame spread - burning droplets - penetration EN/TS 1187 „N” Metoda 1"},{"_id":"6a5a55f19af9f73f38251359","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drogowe urządzenia przeciwhałasowe E","test_object_en":"Road traffic noise reducing devices E","methodology":"Odporność na pożar zarośli - zasięg i rodzaj zniszczenia - rozprzestrzenienie płomienia","methodology_en":"Resistance to brushwood fire - extent and type of damage - flame spread","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na pożar zarośli - zasięg i rodzaj zniszczenia - rozprzestrzenienie płomienia","reference":"PN-EN 1794-3","norm_bases":["PN-EN 1794-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drogowe urządzenia przeciwhałasowe E Odporność na pożar zarośli - zasięg i rodzaj zniszczenia - rozprzestrzenienie płomienia PN-EN 1794-3 Drogowe urzadzenia przeciwhalasowe E Odpornosc na pozar zarosli - zasieg i rodzaj zniszczenia - rozprzestrzenienie plomienia PN-EN 1794-3","categories":["other"],"row_index":1093,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Road traffic noise reducing devices E Resistance to brushwood fire - extent and type of damage - flame spread PN-EN 1794-3","search_zh":"道路降噪设施 E PN-EN 1794-3","test_object_zh":"道路降噪设施 E"},{"_id":"6a5a55f19af9f73f3825135a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Ściany zewnętrzne i wewnętrzne E","test_object_en":"External and internal walls E","methodology":"Stopień rozprzestrzeniania ognia przez ściany - zasięg i rodzaj zniszczenia - rozprzestrzenienia płomienia - temperatura na liniach L1 i L2","methodology_en":"Degree of fire spread by walls - extent and type of damage - flame spread - temperature on lines L1 and L2","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stopień rozprzestrzeniania ognia przez ściany - zasięg i rodzaj zniszczenia - rozprzestrzenienia płomienia - temperatura na liniach L1 i L2","reference":"PN-B-02867","norm_bases":["PN-B-02867"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ściany zewnętrzne i wewnętrzne E Stopień rozprzestrzeniania ognia przez ściany - zasięg i rodzaj zniszczenia - rozprzestrzenienia płomienia - temperatura na liniach L1 i L2 PN-B-02867 Sciany zewnetrzne i wewnetrzne E Stopien rozprzestrzeniania ognia przez sciany - zasieg i rodzaj zniszczenia - rozprzestrzenienia plomienia - temperatura na liniach L1 i L2 PN-B-02867","categories":["other"],"row_index":1094,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"External and internal walls E Degree of fire spread by walls - extent and type of damage - flame spread - temperature on lines L1 and L2 PN-B-02867"},{"_id":"6a5a55f19af9f73f3825135b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Dymoszczelne drzwi, bramy i żaluzje E","test_object_en":"Smoke control doors, gates and shutters E","methodology":"Dymoszczelność, samozamykalność, samoczynne zamykanie, funkcja zwalniania (zdolność do zwolnienia) - strumień przepływu - samozamykalność","methodology_en":"Smoke leakage, self-closing, automatic closing, release function (release capability) - flow rate - self-closing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Dymoszczelność, samozamykalność, samoczynne zamykanie, funkcja zwalniania (zdolność do zwolnienia) - strumień przepływu - samozamykalność","reference":"PN-EN 1634-3 PN-EN 16034","norm_bases":["PN-EN 1634-3 PN-EN 16034"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Dymoszczelne drzwi, bramy i żaluzje E Dymoszczelność, samozamykalność, samoczynne zamykanie, funkcja zwalniania (zdolność do zwolnienia) - strumień przepływu - samozamykalność PN-EN 1634-3 PN-EN 16034 Dymoszczelne drzwi, bramy i zaluzje E Dymoszczelnosc, samozamykalnosc, samoczynne zamykanie, funkcja zwalniania (zdolnosc do zwolnienia) - strumien przeplywu - samozamykalnosc PN-EN 1634-3 PN-EN 16034","categories":["other"],"row_index":1095,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Smoke control doors, gates and shutters E Smoke leakage, self-closing, automatic closing, release function (release capability) - flow rate - self-closing PN-EN 1634-3 PN-EN 16034"},{"_id":"6a5a55f19af9f73f3825135c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Drzwi przystankowe do dźwigów E","test_object_en":"Landing doors for lifts E","methodology":"Szczelność ogniowa, izolacyjność ogniowa, natężenie promieniowania - utrzymywanie się płomienia - przecieki CO 2 - przyrost temperatury średniej - przyrost temperatury maksymalnej - natężenie promieniowania - deformacja","methodology_en":"Fire integrity, fire insulation, radiation intensity - sustained flaming - CO 2 leakage - mean temperature rise - maximum temperature rise - radiation intensity - deformation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność ogniowa, izolacyjność ogniowa, natężenie promieniowania - utrzymywanie się płomienia - przecieki CO 2 - przyrost temperatury średniej - przyrost temperatury maksymalnej - natężenie promieniowania - deformacja","reference":"PN-EN 81-58","norm_bases":["PN-EN 81-58"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi przystankowe do dźwigów E Szczelność ogniowa, izolacyjność ogniowa, natężenie promieniowania - utrzymywanie się płomienia - przecieki CO 2 - przyrost temperatury średniej - przyrost temperatury maksymalnej - natężenie promieniowania - deformacja PN-EN 81-58 Drzwi przystankowe do dzwigow E Szczelnosc ogniowa, izolacyjnosc ogniowa, natezenie promieniowania - utrzymywanie sie plomienia - przecieki CO 2 - przyrost temperatury sredniej - przyrost temperatury maksymalnej - natezenie promieniowania - deformacja PN-EN 81-58","categories":["construction"],"row_index":1096,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Landing doors for lifts E Fire integrity, fire insulation, radiation intensity - sustained flaming - CO 2 leakage - mean temperature rise - maximum temperature rise - radiation intensity - deformation PN-EN 81-58"},{"_id":"6a5a55f19af9f73f3825135d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kable i przewody elektryczne E","test_object_en":"Electrical cables and wires E","methodology":"Pionowe rozprzestrzenianie płomieni po pojedynczym izolowanym przewodzie lub kablu - zasięg i rodzaj zniszczenia - rozprzestrzenienie płomienia - płonące krople","methodology_en":"Vertical flame spread on a single insulated wire or cable - extent and type of damage - flame spread - flaming droplets","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pionowe rozprzestrzenianie płomieni po pojedynczym izolowanym przewodzie lub kablu - zasięg i rodzaj zniszczenia - rozprzestrzenienie płomienia - płonące krople","reference":"PN-EN 60332-1-3 PN-EN 60332-1-1 PN-EN 60332-1-2 „N” PN-EN 60695-11-2 PN-EN 60332-2-1 PN-EN 60332-2-2","norm_bases":["PN-EN 60332-1-3 PN-EN 60332-1-1 PN-EN 60332-1-2 „N” PN-EN 60695-11-2 PN-EN 60332-2-1 PN-EN 60332-2-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i przewody elektryczne E Pionowe rozprzestrzenianie płomieni po pojedynczym izolowanym przewodzie lub kablu - zasięg i rodzaj zniszczenia - rozprzestrzenienie płomienia - płonące krople PN-EN 60332-1-3 PN-EN 60332-1-1 PN-EN 60332-1-2 „N” PN-EN 60695-11-2 PN-EN 60332-2-1 PN-EN 60332-2-2 Kable i przewody elektryczne E Pionowe rozprzestrzenianie plomieni po pojedynczym izolowanym przewodzie lub kablu - zasieg i rodzaj zniszczenia - rozprzestrzenienie plomienia - plonace krople PN-EN 60332-1-3 PN-EN 60332-1-1 PN-EN 60332-1-2 „N” PN-EN 60695-11-2 PN-EN 60332-2-1 PN-EN 60332-2-2","categories":["other"],"row_index":1097,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical cables and wires E Vertical flame spread on a single insulated wire or cable - extent and type of damage - flame spread - flaming droplets PN-EN 60332-1-3 PN-EN 60332-1-1 PN-EN 60332-1-2 „N” PN-EN 60695-11-2 PN-EN 60332-2-1 PN-EN 60332-2-2","search_zh":"电缆与电线 E PN-EN 60332-1-3 PN-EN 60332-1-1 PN-EN 60332-1-2 „N” PN-EN 60695-11-2 PN-EN 60332-2-1 PN-EN 60332-2-2","test_object_zh":"电缆与电线 E"},{"_id":"6a5a55f19af9f73f3825135e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kable i przewody elektryczne E","test_object_en":"Electrical cables and wires E","methodology":"Ciepło spalania - wzrost temperatury","methodology_en":"Heat of combustion - temperature rise","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciepło spalania - wzrost temperatury","reference":"PN-EN ISO 1716","norm_bases":["PN-EN ISO 1716"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i przewody elektryczne E Ciepło spalania - wzrost temperatury PN-EN ISO 1716 Kable i przewody elektryczne E Cieplo spalania - wzrost temperatury PN-EN ISO 1716","categories":["other"],"row_index":1098,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical cables and wires E Heat of combustion - temperature rise PN-EN ISO 1716","search_zh":"电缆与电线 E PN-EN ISO 1716","test_object_zh":"电缆与电线 E"},{"_id":"6a5a55f19af9f73f3825135f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kable i przewody elektryczne E","test_object_en":"Electrical cables and wires E","methodology":"Ciągłość obwodu pod działaniem ognia - czas życia - tłumienność","methodology_en":"Circuit integrity under fire conditions - survival time - attenuation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciągłość obwodu pod działaniem ognia - czas życia - tłumienność","reference":"PN-IEC 60331-21 PN-IEC 60331-23 PN-IEC 60331-25","norm_bases":["PN-IEC 60331-21 PN-IEC 60331-23 PN-IEC 60331-25"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i przewody elektryczne E Ciągłość obwodu pod działaniem ognia - czas życia - tłumienność PN-IEC 60331-21 PN-IEC 60331-23 PN-IEC 60331-25 Kable i przewody elektryczne E Ciaglosc obwodu pod dzialaniem ognia - czas zycia - tlumiennosc PN-IEC 60331-21 PN-IEC 60331-23 PN-IEC 60331-25","categories":["other"],"row_index":1099,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical cables and wires E Circuit integrity under fire conditions - survival time - attenuation PN-IEC 60331-21 PN-IEC 60331-23 PN-IEC 60331-25","search_zh":"电缆与电线 E PN-IEC 60331-21 PN-IEC 60331-23 PN-IEC 60331-25","test_object_zh":"电缆与电线 E"},{"_id":"6a5a55f19af9f73f38251360","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kable i przewody elektryczne E","test_object_en":"Electrical cables and wires E","methodology":"Ciągłość dostaw energii i sygnału - czas zapewnienia ciągłości dostawy energii i/lub sygnału","methodology_en":"Continuity of power and signal supply - time of ensuring continuity of power and/or signal supply","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciągłość dostaw energii i sygnału - czas zapewnienia ciągłości dostawy energii i/lub sygnału","reference":"DIN 4102-12","norm_bases":["DIN 4102-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i przewody elektryczne E Ciągłość dostaw energii i sygnału - czas zapewnienia ciągłości dostawy energii i/lub sygnału DIN 4102-12 Kable i przewody elektryczne E Ciaglosc dostaw energii i sygnalu - czas zapewnienia ciaglosci dostawy energii i/lub sygnalu DIN 4102-12","categories":["other"],"row_index":1100,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical cables and wires E Continuity of power and signal supply - time of ensuring continuity of power and/or signal supply DIN 4102-12","search_zh":"电缆与电线 E DIN 4102-12","test_object_zh":"电缆与电线 E"},{"_id":"6a5a55f19af9f73f38251361","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kable i przewody elektryczne E","test_object_en":"Electrical cables and wires E","methodology":"Wydzielanie ciepła, wydzielanie dymu, rozprzestrzenianie płomienia - wydzielanie ciepła - wydzielanie dymu - spadające płonące fragmenty - rozprzestrzenianie płomienia - czas zgaśnięcia próbki","methodology_en":"Heat release, smoke release, flame spread - heat release - smoke release - falling flaming fragments - flame spread - time to extinction of the specimen","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wydzielanie ciepła, wydzielanie dymu, rozprzestrzenianie płomienia - wydzielanie ciepła - wydzielanie dymu - spadające płonące fragmenty - rozprzestrzenianie płomienia - czas zgaśnięcia próbki","reference":"PN-EN 50399 „N” PN-EN IEC 60332-3-10 PN-EN IEC 60332-3-21 PN-EN IEC 60332-3-22 PN-EN IEC 60332-3-23 PN-EN IEC 60332-3-24 PN-EN IEC 60332-3-25","norm_bases":["PN-EN 50399 „N” PN-EN IEC 60332-3-10 PN-EN IEC 60332-3-21 PN-EN IEC 60332-3-22 PN-EN IEC 60332-3-23 PN-EN IEC 60332-3-24 PN-EN IEC 60332-3-25"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i przewody elektryczne E Wydzielanie ciepła, wydzielanie dymu, rozprzestrzenianie płomienia - wydzielanie ciepła - wydzielanie dymu - spadające płonące fragmenty - rozprzestrzenianie płomienia - czas zgaśnięcia próbki PN-EN 50399 „N” PN-EN IEC 60332-3-10 PN-EN IEC 60332-3-21 PN-EN IEC 60332-3-22 PN-EN IEC 60332-3-23 PN-EN IEC 60332-3-24 PN-EN IEC 60332-3-25 Kable i przewody elektryczne E Wydzielanie ciepla, wydzielanie dymu, rozprzestrzenianie plomienia - wydzielanie ciepla - wydzielanie dymu - spadajace plonace fragmenty - rozprzestrzenianie plomienia - czas zgasniecia probki PN-EN 50399 „N” PN-EN IEC 60332-3-10 PN-EN IEC 60332-3-21 PN-EN IEC 60332-3-22 PN-EN IEC 60332-3-23 PN-EN IEC 60332-3-24 PN-EN IEC 60332-3-25","categories":["other"],"row_index":1101,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical cables and wires E Heat release, smoke release, flame spread - heat release - smoke release - falling flaming fragments - flame spread - time to extinction of the specimen PN-EN 50399 „N” PN-EN IEC 60332-3-10 PN-EN IEC 60332-3-21 PN-EN IEC 60332-3-22 PN-EN IEC 60332-3-23 PN-EN IEC 60332-3-24 PN-EN IEC 60332-3-25","search_zh":"电缆与电线 E PN-EN 50399 „N” PN-EN IEC 60332-3-10 PN-EN IEC 60332-3-21 PN-EN IEC 60332-3-22 PN-EN IEC 60332-3-23 PN-EN IEC 60332-3-24 PN-EN IEC 60332-3-25","test_object_zh":"电缆与电线 E"},{"_id":"6a5a55f19af9f73f38251362","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kable i przewody elektryczne E","test_object_en":"Electrical cables and wires E","methodology":"Dymotwórczość - transmitancja","methodology_en":"Smoke generation - transmittance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Dymotwórczość - transmitancja","reference":"PN-EN 61034-2 „N” PN-EN 61034-1","norm_bases":["PN-EN 61034-2 „N” PN-EN 61034-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i przewody elektryczne E Dymotwórczość - transmitancja PN-EN 61034-2 „N” PN-EN 61034-1 Kable i przewody elektryczne E Dymotworczosc - transmitancja PN-EN 61034-2 „N” PN-EN 61034-1","categories":["other"],"row_index":1102,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical cables and wires E Smoke generation - transmittance PN-EN 61034-2 „N” PN-EN 61034-1","search_zh":"电缆与电线 E PN-EN 61034-2 „N” PN-EN 61034-1","test_object_zh":"电缆与电线 E"},{"_id":"6a5a55f19af9f73f38251363","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kanały i szyby instalacyjne E","test_object_en":"Service ducts and shafts E","methodology":"Szczelność ogniowa, izolacyjność ogniowa - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury maksymalnej/średniej","methodology_en":"Fire integrity, fire insulation - sustained flaming - openings and cracks - ignition of the cotton wool pad - maximum/mean temperature rise","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność ogniowa, izolacyjność ogniowa - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury maksymalnej/średniej","reference":"PN-EN 1366-5 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”","norm_bases":["PN-EN 1366-5 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kanały i szyby instalacyjne E Szczelność ogniowa, izolacyjność ogniowa - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury maksymalnej/średniej PN-EN 1366-5 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” Kanaly i szyby instalacyjne E Szczelnosc ogniowa, izolacyjnosc ogniowa - utrzymywanie sie plomienia - otwory i pekniecia - zapalenie tamponu z waty bawelnianej - przyrost temperatury maksymalnej/sredniej PN-EN 1366-5 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”","categories":["construction"],"row_index":1103,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Service ducts and shafts E Fire integrity, fire insulation - sustained flaming - openings and cracks - ignition of the cotton wool pad - maximum/mean temperature rise PN-EN 1366-5 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”"},{"_id":"6a5a55f19af9f73f38251364","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klapy dymowe E","test_object_en":"Smoke vents E","methodology":"Niezawodność działania","methodology_en":"Operational reliability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Niezawodność działania","reference":"PN-EN 12101-2","norm_bases":["PN-EN 12101-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klapy dymowe E Niezawodność działania PN-EN 12101-2 Klapy dymowe E Niezawodnosc dzialania PN-EN 12101-2","categories":["other"],"row_index":1104,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Smoke vents E Operational reliability PN-EN 12101-2","search_zh":"排烟窗 E PN-EN 12101-2","test_object_zh":"排烟窗 E"},{"_id":"6a5a55f19af9f73f38251365","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klapy dymowe E","test_object_en":"Smoke vents E","methodology":"Odporność klap dymowych na wysoką temperaturę - czas otwierania do pozycji oddymiania - zmniejszenie powierzchni otworu","methodology_en":"Resistance of smoke vents to high temperature - opening time to the smoke extraction position - reduction of the opening area","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność klap dymowych na wysoką temperaturę - czas otwierania do pozycji oddymiania - zmniejszenie powierzchni otworu","reference":"PN-EN 12101-2","norm_bases":["PN-EN 12101-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klapy dymowe E Odporność klap dymowych na wysoką temperaturę - czas otwierania do pozycji oddymiania - zmniejszenie powierzchni otworu PN-EN 12101-2 Klapy dymowe E Odpornosc klap dymowych na wysoka temperature - czas otwierania do pozycji oddymiania - zmniejszenie powierzchni otworu PN-EN 12101-2","categories":["other"],"row_index":1105,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Smoke vents E Resistance of smoke vents to high temperature - opening time to the smoke extraction position - reduction of the opening area PN-EN 12101-2","search_zh":"排烟窗 E PN-EN 12101-2","test_object_zh":"排烟窗 E"},{"_id":"6a5a55f19af9f73f38251366","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klapy dymowe E","test_object_en":"Smoke vents E","methodology":"Pewność działania pod obciążeniem wiatrem - czas otwierania","methodology_en":"Operational reliability under wind load - opening time","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pewność działania pod obciążeniem wiatrem - czas otwierania","reference":"PN-EN 12101-2","norm_bases":["PN-EN 12101-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klapy dymowe E Pewność działania pod obciążeniem wiatrem - czas otwierania PN-EN 12101-2 Klapy dymowe E Pewnosc dzialania pod obciazeniem wiatrem - czas otwierania PN-EN 12101-2","categories":["other"],"row_index":1106,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Smoke vents E Operational reliability under wind load - opening time PN-EN 12101-2","search_zh":"排烟窗 E PN-EN 12101-2","test_object_zh":"排烟窗 E"},{"_id":"6a5a55f19af9f73f38251367","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klapy dymowe E","test_object_en":"Smoke vents E","methodology":"Pewność działania pod obciążeniem - czas otwierania","methodology_en":"Operational reliability under load - opening time","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pewność działania pod obciążeniem - czas otwierania","reference":"PN-EN 12101-2","norm_bases":["PN-EN 12101-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klapy dymowe E Pewność działania pod obciążeniem - czas otwierania PN-EN 12101-2 Klapy dymowe E Pewnosc dzialania pod obciazeniem - czas otwierania PN-EN 12101-2","categories":["other"],"row_index":1107,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Smoke vents E Operational reliability under load - opening time PN-EN 12101-2","search_zh":"排烟窗 E PN-EN 12101-2","test_object_zh":"排烟窗 E"},{"_id":"6a5a55f19af9f73f38251368","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Klapy odcinające w systemach wentylacji pożarowej E","test_object_en":"Smoke control dampers in fire ventilation systems E","methodology":"Szczelność ogniowa, izolacyjność ogniowa, dymoszczelność - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury maksymalnej/średniej - strumień przepływu/przecieki - zachowanie przekroju poprzecznego","methodology_en":"Fire integrity, fire insulation, smoke tightness - sustained flaming - openings and cracks - ignition of the cotton wool pad - maximum/mean temperature rise - flow rate/leakage - maintenance of cross-section","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność ogniowa, izolacyjność ogniowa, dymoszczelność - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury maksymalnej/średniej - strumień przepływu/przecieki - zachowanie przekroju poprzecznego","reference":"PN-EN 1366-10 PN-EN 1363-1 „N” PN-EN 1363-2 „N” PN-EN 1751","norm_bases":["PN-EN 1366-10 PN-EN 1363-1 „N” PN-EN 1363-2 „N” PN-EN 1751"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Klapy odcinające w systemach wentylacji pożarowej E Szczelność ogniowa, izolacyjność ogniowa, dymoszczelność - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury maksymalnej/średniej - strumień przepływu/przecieki - zachowanie przekroju poprzecznego PN-EN 1366-10 PN-EN 1363-1 „N” PN-EN 1363-2 „N” PN-EN 1751 Klapy odcinajace w systemach wentylacji pozarowej E Szczelnosc ogniowa, izolacyjnosc ogniowa, dymoszczelnosc - utrzymywanie sie plomienia - otwory i pekniecia - zapalenie tamponu z waty bawelnianej - przyrost temperatury maksymalnej/sredniej - strumien przeplywu/przecieki - zachowanie przekroju poprzecznego PN-EN 1366-10 PN-EN 1363-1 „N” PN-EN 1363-2 „N” PN-EN 1751","categories":["construction"],"row_index":1108,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Smoke control dampers in fire ventilation systems E Fire integrity, fire insulation, smoke tightness - sustained flaming - openings and cracks - ignition of the cotton wool pad - maximum/mean temperature rise - flow rate/leakage - maintenance of cross-section PN-EN 1366-10 PN-EN 1363-1 „N” PN-EN 1363-2 „N” PN-EN 1751"},{"_id":"6a5a55f19af9f73f38251369","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Kurtyny dymowe E","test_object_en":"Smoke curtains E","methodology":"Stabilność kurtyn dymowych - niezawodność i trwałość - domyślne przejście do pozycji pracy - czas odpowiedzi i funkcjonowania - przepuszczalność dymu - zastosowanie szczelinomierzy - utrzymywanie się płonienia - zawalenie się - występowanie płonących kropel lub cząstek","methodology_en":"Stability of smoke curtains - reliability and durability - default movement to the operating position - response and operating time - smoke permeability - use of feeler gauges - continued flaming - collapse - occurrence of flaming droplets or particles","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stabilność kurtyn dymowych - niezawodność i trwałość - domyślne przejście do pozycji pracy - czas odpowiedzi i funkcjonowania - przepuszczalność dymu - zastosowanie szczelinomierzy - utrzymywanie się płonienia - zawalenie się - występowanie płonących kropel lub cząstek","reference":"PN-EN 12101-1","norm_bases":["PN-EN 12101-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kurtyny dymowe E Stabilność kurtyn dymowych - niezawodność i trwałość - domyślne przejście do pozycji pracy - czas odpowiedzi i funkcjonowania - przepuszczalność dymu - zastosowanie szczelinomierzy - utrzymywanie się płonienia - zawalenie się - występowanie płonących kropel lub cząstek PN-EN 12101-1 Kurtyny dymowe E Stabilnosc kurtyn dymowych - niezawodnosc i trwalosc - domyslne przejscie do pozycji pracy - czas odpowiedzi i funkcjonowania - przepuszczalnosc dymu - zastosowanie szczelinomierzy - utrzymywanie sie plonienia - zawalenie sie - wystepowanie plonacych kropel lub czastek PN-EN 12101-1","categories":["other"],"row_index":1109,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Smoke curtains E Stability of smoke curtains - reliability and durability - default movement to the operating position - response and operating time - smoke permeability - use of feeler gauges - continued flaming - collapse - occurrence of flaming droplets or particles PN-EN 12101-1"},{"_id":"6a5a55f19af9f73f3825136a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Materiały obiciowe i wypełnienia stosowane w siedziskach tapicerowanych, fotele, siedziska E","test_object_en":"Upholstery and filling used in upholstered seats, armchairs, chairs E","methodology":"Zapalność mebli tapicerowanych - spalanie płomieniowe - postępujące tlenie","methodology_en":"Ignitability of upholstered furniture - flame burning - progressive smouldering","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zapalność mebli tapicerowanych - spalanie płomieniowe - postępujące tlenie","reference":"PN-EN 1021-1 PN-EN 1021-2","norm_bases":["PN-EN 1021-1 PN-EN 1021-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały obiciowe i wypełnienia stosowane w siedziskach tapicerowanych, fotele, siedziska E Zapalność mebli tapicerowanych - spalanie płomieniowe - postępujące tlenie PN-EN 1021-1 PN-EN 1021-2 Materialy obiciowe i wypelnienia stosowane w siedziskach tapicerowanych, fotele, siedziska E Zapalnosc mebli tapicerowanych - spalanie plomieniowe - postepujace tlenie PN-EN 1021-1 PN-EN 1021-2","categories":["materials"],"row_index":1110,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Upholstery and filling used in upholstered seats, armchairs, chairs E Ignitability of upholstered furniture - flame burning - progressive smouldering PN-EN 1021-1 PN-EN 1021-2"},{"_id":"6a5a55f19af9f73f3825136b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Membrany pionowe E","test_object_en":"Vertical membranes E","methodology":"Skuteczność ogniochronna membrany pionowej - czas osiągnięcia temperatury krytycznej","methodology_en":"Fire protection effectiveness of a vertical membrane - time to reach the critical temperature","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność ogniochronna membrany pionowej - czas osiągnięcia temperatury krytycznej","reference":"PN-EN 13381-2 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”","norm_bases":["PN-EN 13381-2 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Membrany pionowe E Skuteczność ogniochronna membrany pionowej - czas osiągnięcia temperatury krytycznej PN-EN 13381-2 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” Membrany pionowe E Skutecznosc ogniochronna membrany pionowej - czas osiagniecia temperatury krytycznej PN-EN 13381-2 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”","categories":["other"],"row_index":1111,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Vertical membranes E Fire protection effectiveness of a vertical membrane - time to reach the critical temperature PN-EN 13381-2 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”"},{"_id":"6a5a55f19af9f73f3825136c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Membrany poziome E","test_object_en":"Horizontal membranes E","methodology":"Skuteczność ogniochronna membrany poziomej - czas osiągnięcia temperatury krytycznej","methodology_en":"Fire protection effectiveness of a horizontal membrane - time to reach the critical temperature","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność ogniochronna membrany poziomej - czas osiągnięcia temperatury krytycznej","reference":"PN-EN 1363-1 „N” PN-EN 1363-2 „N” PN-EN 13381-1 „N”","norm_bases":["PN-EN 1363-1 „N” PN-EN 1363-2 „N” PN-EN 13381-1 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Membrany poziome E Skuteczność ogniochronna membrany poziomej - czas osiągnięcia temperatury krytycznej PN-EN 1363-1 „N” PN-EN 1363-2 „N” PN-EN 13381-1 „N” Membrany poziome E Skutecznosc ogniochronna membrany poziomej - czas osiagniecia temperatury krytycznej PN-EN 1363-1 „N” PN-EN 1363-2 „N” PN-EN 13381-1 „N”","categories":["other"],"row_index":1112,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Horizontal membranes E Fire protection effectiveness of a horizontal membrane - time to reach the critical temperature PN-EN 1363-1 „N” PN-EN 1363-2 „N” PN-EN 13381-1 „N”"},{"_id":"6a5a55f19af9f73f3825136d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okładziny E","test_object_en":"Coverings E","methodology":"Zdolność do zabezpieczania ogniochronnego - czas osiągnięcia temperatury krytycznej","methodology_en":"Fire protection ability - time to reach the critical temperature","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność do zabezpieczania ogniochronnego - czas osiągnięcia temperatury krytycznej","reference":"PN-EN 1363-1 „N” PN-EN 1363-2 „N” PN-EN 14135 „N”","norm_bases":["PN-EN 1363-1 „N” PN-EN 1363-2 „N” PN-EN 14135 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okładziny E Zdolność do zabezpieczania ogniochronnego - czas osiągnięcia temperatury krytycznej PN-EN 1363-1 „N” PN-EN 1363-2 „N” PN-EN 14135 „N” Okladziny E Zdolnosc do zabezpieczania ogniochronnego - czas osiagniecia temperatury krytycznej PN-EN 1363-1 „N” PN-EN 1363-2 „N” PN-EN 14135 „N”","categories":["other"],"row_index":1113,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Coverings E Fire protection ability - time to reach the critical temperature PN-EN 1363-1 „N” PN-EN 1363-2 „N” PN-EN 14135 „N”"},{"_id":"6a5a55f19af9f73f3825136e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Okucia budowlane E","test_object_en":"Building hardware E","methodology":"Przydatność do stosowania w drzwiach przeciwpożarowych/dymoszczelnych - szczelność ogniowa - izolacyjność ogniowa - ryzyko zapalenia - utrzymanie siły zamykającej - odporność na obciążenie","methodology_en":"Suitability for use in fire/smoke-resistant doors - fire integrity - fire insulation - risk of ignition - maintenance of the closing force - resistance to load","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przydatność do stosowania w drzwiach przeciwpożarowych/dymoszczelnych - szczelność ogniowa - izolacyjność ogniowa - ryzyko zapalenia - utrzymanie siły zamykającej - odporność na obciążenie","reference":"PN-EN 1634-2 PN-EN 1363-1 „N” PN-EN 1363-2 „N”","norm_bases":["PN-EN 1634-2 PN-EN 1363-1 „N” PN-EN 1363-2 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okucia budowlane E Przydatność do stosowania w drzwiach przeciwpożarowych/dymoszczelnych - szczelność ogniowa - izolacyjność ogniowa - ryzyko zapalenia - utrzymanie siły zamykającej - odporność na obciążenie PN-EN 1634-2 PN-EN 1363-1 „N” PN-EN 1363-2 „N” Okucia budowlane E Przydatnosc do stosowania w drzwiach przeciwpozarowych/dymoszczelnych - szczelnosc ogniowa - izolacyjnosc ogniowa - ryzyko zapalenia - utrzymanie sily zamykajacej - odpornosc na obciazenie PN-EN 1634-2 PN-EN 1363-1 „N” PN-EN 1363-2 „N”","categories":["construction"],"row_index":1114,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building hardware E Suitability for use in fire/smoke-resistant doors - fire integrity - fire insulation - risk of ignition - maintenance of the closing force - resistance to load PN-EN 1634-2 PN-EN 1363-1 „N” PN-EN 1363-2 „N”"},{"_id":"6a5a55f19af9f73f3825136f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Płyty gipsowo-kartonowe E","test_object_en":"Gypsum plasterboards E","methodology":"Spójność rdzenia przy działaniu wysokiej temperatury - wystąpienie zniszczenia","methodology_en":"Core cohesion under high temperature - occurrence of failure","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Spójność rdzenia przy działaniu wysokiej temperatury - wystąpienie zniszczenia","reference":"PN-EN 520 „N”","norm_bases":["PN-EN 520 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyty gipsowo-kartonowe E Spójność rdzenia przy działaniu wysokiej temperatury - wystąpienie zniszczenia PN-EN 520 „N” Plyty gipsowo-kartonowe E Spojnosc rdzenia przy dzialaniu wysokiej temperatury - wystapienie zniszczenia PN-EN 520 „N”","categories":["other"],"row_index":1115,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gypsum plasterboards E Core cohesion under high temperature - occurrence of failure PN-EN 520 „N”"},{"_id":"6a5a55f19af9f73f38251370","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Podłogi podniesione z dostępem i podłogi podniesione E","test_object_en":"Raised access floors and raised floors E","methodology":"Nośność ogniowa, szczelność ogniowa, izolacyjność ogniowa - deformacja D - prędkość deformacji dD/dt - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury średniej - przyrost temperatury maksymalnej","methodology_en":"Loadbearing capacity, integrity, insulation - deformation D - rate of deformation dD/dt - sustained flaming - openings and cracks - ignition of the cotton wool pad - mean temperature rise - maximum temperature rise","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność ogniowa, szczelność ogniowa, izolacyjność ogniowa - deformacja D - prędkość deformacji dD/dt - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury średniej - przyrost temperatury maksymalnej","reference":"PN-EN 1366-6 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”","norm_bases":["PN-EN 1366-6 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podłogi podniesione z dostępem i podłogi podniesione E Nośność ogniowa, szczelność ogniowa, izolacyjność ogniowa - deformacja D - prędkość deformacji dD/dt - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury średniej - przyrost temperatury maksymalnej PN-EN 1366-6 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” Podlogi podniesione z dostepem i podlogi podniesione E Nosnosc ogniowa, szczelnosc ogniowa, izolacyjnosc ogniowa - deformacja D - predkosc deformacji dD/dt - utrzymywanie sie plomienia - otwory i pekniecia - zapalenie tamponu z waty bawelnianej - przyrost temperatury sredniej - przyrost temperatury maksymalnej PN-EN 1366-6 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”","categories":["construction"],"row_index":1116,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Raised access floors and raised floors E Loadbearing capacity, integrity, insulation - deformation D - rate of deformation dD/dt - sustained flaming - openings and cracks - ignition of the cotton wool pad - mean temperature rise - maximum temperature rise PN-EN 1366-6 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”"},{"_id":"6a5a55f19af9f73f38251371","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Posadzki i wykładziny podłogowe E","test_object_en":"Floorings and floor coverings E","methodology":"Właściwości ogniowe Metoda płyty promieniującej - krytyczny strumień cieplny - wydzielanie dymu","methodology_en":"Fire properties Radiant panel method - critical heat flux - smoke production","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Właściwości ogniowe Metoda płyty promieniującej - krytyczny strumień cieplny - wydzielanie dymu","reference":"PN-EN ISO 9239-1 „N”","norm_bases":["PN-EN ISO 9239-1 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Posadzki i wykładziny podłogowe E Właściwości ogniowe Metoda płyty promieniującej - krytyczny strumień cieplny - wydzielanie dymu PN-EN ISO 9239-1 „N” Posadzki i wykladziny podlogowe E Wlasciwosci ogniowe Metoda plyty promieniujacej - krytyczny strumien cieplny - wydzielanie dymu PN-EN ISO 9239-1 „N”","categories":["construction"],"row_index":1117,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Floorings and floor coverings E Fire properties Radiant panel method - critical heat flux - smoke production PN-EN ISO 9239-1 „N”"},{"_id":"6a5a55f19af9f73f38251372","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Powłoki i izolacje stosowane w kablach elektrycznych E","test_object_en":"Sheaths and insulation used in electric cables E","methodology":"Kwasowość gazów powstałych podczas spalania materiałów kabli elektrycznych poprzez pomiar pH i konduktywności","methodology_en":"Acidity of gases evolved during combustion of materials from electric cables by measurement of pH and conductivity","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Kwasowość gazów powstałych podczas spalania materiałów kabli elektrycznych poprzez pomiar pH i konduktywności","reference":"PN-EN 60754-2 „N”","norm_bases":["PN-EN 60754-2 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki i izolacje stosowane w kablach elektrycznych E Kwasowość gazów powstałych podczas spalania materiałów kabli elektrycznych poprzez pomiar pH i konduktywności PN-EN 60754-2 „N” Powloki i izolacje stosowane w kablach elektrycznych E Kwasowosc gazow powstalych podczas spalania materialow kabli elektrycznych poprzez pomiar pH i konduktywnosci PN-EN 60754-2 „N”","categories":["materials","construction"],"row_index":1118,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sheaths and insulation used in electric cables E Acidity of gases evolved during combustion of materials from electric cables by measurement of pH and conductivity PN-EN 60754-2 „N”"},{"_id":"6a5a55f19af9f73f38251373","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Powłoki i izolacje stosowane w kablach elektrycznych E","test_object_en":"Sheaths and insulation used in electric cables E","methodology":"Zawartość kwaśnego gazu halogenowego powstałego podczas spalania materiałów kabli elektrycznych","methodology_en":"Content of acidic halogen gas formed during combustion of materials of electric cables","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość kwaśnego gazu halogenowego powstałego podczas spalania materiałów kabli elektrycznych","reference":"PN-EN 60754-1","norm_bases":["PN-EN 60754-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki i izolacje stosowane w kablach elektrycznych E Zawartość kwaśnego gazu halogenowego powstałego podczas spalania materiałów kabli elektrycznych PN-EN 60754-1 Powloki i izolacje stosowane w kablach elektrycznych E Zawartosc kwasnego gazu halogenowego powstalego podczas spalania materialow kabli elektrycznych PN-EN 60754-1","categories":["materials","construction"],"row_index":1119,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sheaths and insulation used in electric cables E Content of acidic halogen gas formed during combustion of materials of electric cables PN-EN 60754-1"},{"_id":"6a5a55f19af9f73f38251374","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Przeciwpożarowe drzwi, bramy, żaluzje i otwieralne okna E","test_object_en":"Fire doors, gates, shutters and openable windows E","methodology":"Szczelność ogniowa, izolacyjność ogniowa, natężenie promieniowania, samozamykalność, samoczynne zamykanie, funkcja zwalniania (zdolność do zwolnienia) - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury średniej - przyrost temperatury maksymalnej - natężenie promieniowania - efekt oddziaływania mechanicznego - zdolność do samozamykalności - deformacja + Także za pomocą wyposażenia producenta","methodology_en":"Fire integrity, fire insulation, radiation intensity, self-closing ability, automatic closing, release function (release capability) - sustained flaming - openings and cracks - ignition of the cotton wool pad - mean temperature rise - maximum temperature rise - radiation intensity - effect of mechanical impact - self-closing capability - deformation + Also using the manufacturer's equipment","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność ogniowa, izolacyjność ogniowa, natężenie promieniowania, samozamykalność, samoczynne zamykanie, funkcja zwalniania (zdolność do zwolnienia) - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury średniej - przyrost temperatury maksymalnej - natężenie promieniowania - efekt oddziaływania mechanicznego - zdolność do samozamykalności - deformacja + Także za pomocą wyposażenia producenta","reference":"PN-EN 1634-1 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” PN-EN 16034","norm_bases":["PN-EN 1634-1 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” PN-EN 16034"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przeciwpożarowe drzwi, bramy, żaluzje i otwieralne okna E Szczelność ogniowa, izolacyjność ogniowa, natężenie promieniowania, samozamykalność, samoczynne zamykanie, funkcja zwalniania (zdolność do zwolnienia) - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury średniej - przyrost temperatury maksymalnej - natężenie promieniowania - efekt oddziaływania mechanicznego - zdolność do samozamykalności - deformacja + Także za pomocą wyposażenia producenta PN-EN 1634-1 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” PN-EN 16034 Przeciwpozarowe drzwi, bramy, zaluzje i otwieralne okna E Szczelnosc ogniowa, izolacyjnosc ogniowa, natezenie promieniowania, samozamykalnosc, samoczynne zamykanie, funkcja zwalniania (zdolnosc do zwolnienia) - utrzymywanie sie plomienia - otwory i pekniecia - zapalenie tamponu z waty bawelnianej - przyrost temperatury sredniej - przyrost temperatury maksymalnej - natezenie promieniowania - efekt oddzialywania mechanicznego - zdolnosc do samozamykalnosci - deformacja + Takze za pomoca wyposazenia producenta PN-EN 1634-1 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” PN-EN 16034","categories":["construction"],"row_index":1120,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fire doors, gates, shutters and openable windows E Fire integrity, fire insulation, radiation intensity, self-closing ability, automatic closing, release function (release capability) - sustained flaming - openings and cracks - ignition of the cotton wool pad - mean temperature rise - maximum temperature rise - radiation intensity - effect of mechanical impact - self-closing capability - deformation + Also using the manufacturer's equipment PN-EN 1634-1 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” PN-EN 16034"},{"_id":"6a5a55f19af9f73f38251375","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Przeciwpożarowe klapy odcinające E","test_object_en":"Fire dampers E","methodology":"Szczelność ogniowa, izolacyjność ogniowa, dymoszczelność - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury maksymalnej/średniej - strumień przepływu/przecieki","methodology_en":"Fire integrity, fire insulation, smoke leakage - sustained flaming - openings and cracks - ignition of the cotton wool pad - maximum/mean temperature rise - flow rate/leakage","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność ogniowa, izolacyjność ogniowa, dymoszczelność - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury maksymalnej/średniej - strumień przepływu/przecieki","reference":"PN-EN 1366-2 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”","norm_bases":["PN-EN 1366-2 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przeciwpożarowe klapy odcinające E Szczelność ogniowa, izolacyjność ogniowa, dymoszczelność - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury maksymalnej/średniej - strumień przepływu/przecieki PN-EN 1366-2 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” Przeciwpozarowe klapy odcinajace E Szczelnosc ogniowa, izolacyjnosc ogniowa, dymoszczelnosc - utrzymywanie sie plomienia - otwory i pekniecia - zapalenie tamponu z waty bawelnianej - przyrost temperatury maksymalnej/sredniej - strumien przeplywu/przecieki PN-EN 1366-2 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”","categories":["construction"],"row_index":1121,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fire dampers E Fire integrity, fire insulation, smoke leakage - sustained flaming - openings and cracks - ignition of the cotton wool pad - maximum/mean temperature rise - flow rate/leakage PN-EN 1366-2 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”"},{"_id":"6a5a55f19af9f73f38251376","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Przeciwpożarowe klapy odcinające E","test_object_en":"Fire dampers E","methodology":"Niezawodność/trwałość przy wielokrotnym otwieraniu i zamykaniu","methodology_en":"Reliability/durability under repeated opening and closing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Niezawodność/trwałość przy wielokrotnym otwieraniu i zamykaniu","reference":"PN-EN 15650","norm_bases":["PN-EN 15650"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przeciwpożarowe klapy odcinające E Niezawodność/trwałość przy wielokrotnym otwieraniu i zamykaniu PN-EN 15650 Przeciwpozarowe klapy odcinajace E Niezawodnosc/trwalosc przy wielokrotnym otwieraniu i zamykaniu PN-EN 15650","categories":["other"],"row_index":1122,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fire dampers E Reliability/durability under repeated opening and closing PN-EN 15650"},{"_id":"6a5a55f19af9f73f38251377","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Przewody i kable w obwodach zabezpieczających E","test_object_en":"Wires and cables in protective circuits E","methodology":"Palność, ciągłość dostaw energii - czas życia","methodology_en":"Flammability, continuity of energy supply - life time","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Palność, ciągłość dostaw energii - czas życia","reference":"PN-EN 50200","norm_bases":["PN-EN 50200"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody i kable w obwodach zabezpieczających E Palność, ciągłość dostaw energii - czas życia PN-EN 50200 Przewody i kable w obwodach zabezpieczajacych E Palnosc, ciaglosc dostaw energii - czas zycia PN-EN 50200","categories":["other"],"row_index":1123,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wires and cables in protective circuits E Flammability, continuity of energy supply - life time PN-EN 50200"},{"_id":"6a5a55f19af9f73f38251378","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Przewody oddymiające E","test_object_en":"Smoke extraction ducts E","methodology":"Szczelność ogniowa, izolacyjność ogniowa, dymoszczelność - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury maksymalnej/średniej - strumień przepływu/przecieki - stabilność mechaniczna - zachowanie przekroju poprzecznego","methodology_en":"Fire integrity, fire insulation, smoke tightness - sustained flaming - openings and cracks - ignition of the cotton wool pad - maximum/mean temperature rise - flow rate/leakage - mechanical stability - maintenance of cross-section","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność ogniowa, izolacyjność ogniowa, dymoszczelność - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury maksymalnej/średniej - strumień przepływu/przecieki - stabilność mechaniczna - zachowanie przekroju poprzecznego","reference":"PN-EN 1366-8 PN-EN 1363-1 „N” PN-EN 1363-2 „N”","norm_bases":["PN-EN 1366-8 PN-EN 1363-1 „N” PN-EN 1363-2 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody oddymiające E Szczelność ogniowa, izolacyjność ogniowa, dymoszczelność - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury maksymalnej/średniej - strumień przepływu/przecieki - stabilność mechaniczna - zachowanie przekroju poprzecznego PN-EN 1366-8 PN-EN 1363-1 „N” PN-EN 1363-2 „N” Przewody oddymiajace E Szczelnosc ogniowa, izolacyjnosc ogniowa, dymoszczelnosc - utrzymywanie sie plomienia - otwory i pekniecia - zapalenie tamponu z waty bawelnianej - przyrost temperatury maksymalnej/sredniej - strumien przeplywu/przecieki - stabilnosc mechaniczna - zachowanie przekroju poprzecznego PN-EN 1366-8 PN-EN 1363-1 „N” PN-EN 1363-2 „N”","categories":["construction"],"row_index":1124,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Smoke extraction ducts E Fire integrity, fire insulation, smoke tightness - sustained flaming - openings and cracks - ignition of the cotton wool pad - maximum/mean temperature rise - flow rate/leakage - mechanical stability - maintenance of cross-section PN-EN 1366-8 PN-EN 1363-1 „N” PN-EN 1363-2 „N”"},{"_id":"6a5a55f19af9f73f38251379","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Przewody oddymiające obsługujące jedną strefę pożarową E","test_object_en":"Single compartment smoke extraction ducts E","methodology":"Szczelność ogniowa, dymoszczelność - strumień przepływu/przecieki - stabilność mechaniczna - zachowanie przekroju poprzecznego","methodology_en":"Fire integrity, smoke tightness - flow rate/leakage - mechanical stability - maintenance of cross-section","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność ogniowa, dymoszczelność - strumień przepływu/przecieki - stabilność mechaniczna - zachowanie przekroju poprzecznego","reference":"PN-EN 1366-9 PN-EN 1363-1 „N” PN-EN 1363-2 „N”","norm_bases":["PN-EN 1366-9 PN-EN 1363-1 „N” PN-EN 1363-2 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody oddymiające obsługujące jedną strefę pożarową E Szczelność ogniowa, dymoszczelność - strumień przepływu/przecieki - stabilność mechaniczna - zachowanie przekroju poprzecznego PN-EN 1366-9 PN-EN 1363-1 „N” PN-EN 1363-2 „N” Przewody oddymiajace obslugujace jedna strefe pozarowa E Szczelnosc ogniowa, dymoszczelnosc - strumien przeplywu/przecieki - stabilnosc mechaniczna - zachowanie przekroju poprzecznego PN-EN 1366-9 PN-EN 1363-1 „N” PN-EN 1363-2 „N”","categories":["other"],"row_index":1125,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Single compartment smoke extraction ducts E Fire integrity, smoke tightness - flow rate/leakage - mechanical stability - maintenance of cross-section PN-EN 1366-9 PN-EN 1363-1 „N” PN-EN 1363-2 „N”"},{"_id":"6a5a55f19af9f73f3825137a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Przewody wentylacyjne E","test_object_en":"Ventilation ducts E","methodology":"Szczelność ogniowa, izolacyjność ogniowa, dymoszczelność - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury maksymalnej/średniej - strumień przepływu/przecieki","methodology_en":"Fire integrity, fire insulation, smoke leakage - sustained flaming - openings and cracks - ignition of the cotton wool pad - maximum/mean temperature rise - flow rate/leakage","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność ogniowa, izolacyjność ogniowa, dymoszczelność - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury maksymalnej/średniej - strumień przepływu/przecieki","reference":"PN-EN 1366-1 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” PN-EN 15882-1","norm_bases":["PN-EN 1366-1 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” PN-EN 15882-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody wentylacyjne E Szczelność ogniowa, izolacyjność ogniowa, dymoszczelność - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury maksymalnej/średniej - strumień przepływu/przecieki PN-EN 1366-1 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” PN-EN 15882-1 Przewody wentylacyjne E Szczelnosc ogniowa, izolacyjnosc ogniowa, dymoszczelnosc - utrzymywanie sie plomienia - otwory i pekniecia - zapalenie tamponu z waty bawelnianej - przyrost temperatury maksymalnej/sredniej - strumien przeplywu/przecieki PN-EN 1366-1 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” PN-EN 15882-1","categories":["construction"],"row_index":1126,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ventilation ducts E Fire integrity, fire insulation, smoke leakage - sustained flaming - openings and cracks - ignition of the cotton wool pad - maximum/mean temperature rise - flow rate/leakage PN-EN 1366-1 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” PN-EN 15882-1"},{"_id":"6a5a55f19af9f73f3825137b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Schody E","test_object_en":"Stairs E","methodology":"Nośność ogniowa R - maksymalne obciążenie 400T - deformacja D - prędkość deformacji dD/dt","methodology_en":"Loadbearing capacity R - maximum load 400T - deformation D - rate of deformation dD/dt","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność ogniowa R - maksymalne obciążenie 400T - deformacja D - prędkość deformacji dD/dt","reference":"PN-EN 1365-6 PN-EN 1363-1 „N” PN-EN 1363-2 „N”","norm_bases":["PN-EN 1365-6 PN-EN 1363-1 „N” PN-EN 1363-2 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Schody E Nośność ogniowa R - maksymalne obciążenie 400T - deformacja D - prędkość deformacji dD/dt PN-EN 1365-6 PN-EN 1363-1 „N” PN-EN 1363-2 „N” Schody E Nosnosc ogniowa R - maksymalne obciazenie 400T - deformacja D - predkosc deformacji dD/dt PN-EN 1365-6 PN-EN 1363-1 „N” PN-EN 1363-2 „N”","categories":["other"],"row_index":1127,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Stairs E Loadbearing capacity R - maximum load 400T - deformation D - rate of deformation dD/dt PN-EN 1365-6 PN-EN 1363-1 „N” PN-EN 1363-2 „N”"},{"_id":"6a5a55f19af9f73f3825137c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Słupy E","test_object_en":"Poles E","methodology":"Nośność ogniowa R - maksymalne obciążenie 500T - deformacja C - prędkość deformacji dC/dt","methodology_en":"Loadbearing capacity R - maximum load 500T - deformation C - rate of deformation dC/dt","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność ogniowa R - maksymalne obciążenie 500T - deformacja C - prędkość deformacji dC/dt","reference":"PN-EN 1365-4 PN-EN 1363-1 „N” PN-EN 1363-2 „N”","norm_bases":["PN-EN 1365-4 PN-EN 1363-1 „N” PN-EN 1363-2 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Słupy E Nośność ogniowa R - maksymalne obciążenie 500T - deformacja C - prędkość deformacji dC/dt PN-EN 1365-4 PN-EN 1363-1 „N” PN-EN 1363-2 „N” Slupy E Nosnosc ogniowa R - maksymalne obciazenie 500T - deformacja C - predkosc deformacji dC/dt PN-EN 1365-4 PN-EN 1363-1 „N” PN-EN 1363-2 „N”","categories":["other"],"row_index":1128,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Poles E Loadbearing capacity R - maximum load 500T - deformation C - rate of deformation dC/dt PN-EN 1365-4 PN-EN 1363-1 „N” PN-EN 1363-2 „N”"},{"_id":"6a5a55f19af9f73f3825137d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Stropy i dachy E","test_object_en":"Floors and roofs E","methodology":"Nośność ogniowa R - maksymalne obciążenie 400T, szczelność ogniowa, izolacyjność ogniowa, natężenie promieniowania - deformacja D - prędkość deformacji dD/dt - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury średniej - przyrost temperatury maksymalnej - natężenie promieniowania","methodology_en":"Loadbearing capacity R - maximum load 400T, integrity, insulation, radiation - deformation D - rate of deformation dD/dt - sustained flaming - openings and cracks - ignition of the cotton wool pad - mean temperature rise - maximum temperature rise - radiation intensity","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność ogniowa R - maksymalne obciążenie 400T, szczelność ogniowa, izolacyjność ogniowa, natężenie promieniowania - deformacja D - prędkość deformacji dD/dt - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury średniej - przyrost temperatury maksymalnej - natężenie promieniowania","reference":"PN-EN 1365-2 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”","norm_bases":["PN-EN 1365-2 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stropy i dachy E Nośność ogniowa R - maksymalne obciążenie 400T, szczelność ogniowa, izolacyjność ogniowa, natężenie promieniowania - deformacja D - prędkość deformacji dD/dt - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury średniej - przyrost temperatury maksymalnej - natężenie promieniowania PN-EN 1365-2 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” Stropy i dachy E Nosnosc ogniowa R - maksymalne obciazenie 400T, szczelnosc ogniowa, izolacyjnosc ogniowa, natezenie promieniowania - deformacja D - predkosc deformacji dD/dt - utrzymywanie sie plomienia - otwory i pekniecia - zapalenie tamponu z waty bawelnianej - przyrost temperatury sredniej - przyrost temperatury maksymalnej - natezenie promieniowania PN-EN 1365-2 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”","categories":["construction"],"row_index":1129,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Floors and roofs E Loadbearing capacity R - maximum load 400T, integrity, insulation, radiation - deformation D - rate of deformation dD/dt - sustained flaming - openings and cracks - ignition of the cotton wool pad - mean temperature rise - maximum temperature rise - radiation intensity PN-EN 1365-2 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”"},{"_id":"6a5a55f19af9f73f3825137e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Sufity podwieszone E","test_object_en":"Suspended ceilings E","methodology":"Szczelność ogniowa, izolacyjność ogniowa - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury średniej - przyrost temperatury maksymalnej","methodology_en":"Fire integrity, fire insulation - sustained flaming - openings and cracks - ignition of the cotton wool pad - mean temperature rise - maximum temperature rise","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność ogniowa, izolacyjność ogniowa - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury średniej - przyrost temperatury maksymalnej","reference":"PN-EN 1364-2 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”","norm_bases":["PN-EN 1364-2 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Sufity podwieszone E Szczelność ogniowa, izolacyjność ogniowa - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury średniej - przyrost temperatury maksymalnej PN-EN 1364-2 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” Sufity podwieszone E Szczelnosc ogniowa, izolacyjnosc ogniowa - utrzymywanie sie plomienia - otwory i pekniecia - zapalenie tamponu z waty bawelnianej - przyrost temperatury sredniej - przyrost temperatury maksymalnej PN-EN 1364-2 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”","categories":["construction"],"row_index":1130,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Suspended ceilings E Fire integrity, fire insulation - sustained flaming - openings and cracks - ignition of the cotton wool pad - mean temperature rise - maximum temperature rise PN-EN 1364-2 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”"},{"_id":"6a5a55f19af9f73f3825137f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Szafki na butle ze sprężonym gazem E","test_object_en":"Cabinets for pressurized gas cylinders E","methodology":"Odporność ogniowa - temperatura wewnątrz szafki","methodology_en":"Fire resistance - temperature inside the cabinet","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność ogniowa - temperatura wewnątrz szafki","reference":"PN-EN 14470-2","norm_bases":["PN-EN 14470-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Szafki na butle ze sprężonym gazem E Odporność ogniowa - temperatura wewnątrz szafki PN-EN 14470-2 Szafki na butle ze sprezonym gazem E Odpornosc ogniowa - temperatura wewnatrz szafki PN-EN 14470-2","categories":["other"],"row_index":1131,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Cabinets for pressurized gas cylinders E Fire resistance - temperature inside the cabinet PN-EN 14470-2"},{"_id":"6a5a55f19af9f73f38251380","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Systemy transportowe i ich zamknięcia E","test_object_en":"Conveyor systems and their closures E","methodology":"Szczelność ogniowa, izolacyjność ogniowa, natężenie promieniowania, samozamykalność, samoczynne zamykanie, funkcja zwalniania samozamykalność - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury średniej - przyrost temperatury maksymalnej - zdolność do samozamykalności","methodology_en":"Fire integrity, fire insulation, radiation intensity, self-closing ability, automatic closing, release function self-closing ability - sustained flaming - openings and cracks - ignition of the cotton wool pad - mean temperature rise - maximum temperature rise - self-closing capability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność ogniowa, izolacyjność ogniowa, natężenie promieniowania, samozamykalność, samoczynne zamykanie, funkcja zwalniania samozamykalność - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury średniej - przyrost temperatury maksymalnej - zdolność do samozamykalności","reference":"PN-EN 1366-7 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”","norm_bases":["PN-EN 1366-7 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Systemy transportowe i ich zamknięcia E Szczelność ogniowa, izolacyjność ogniowa, natężenie promieniowania, samozamykalność, samoczynne zamykanie, funkcja zwalniania samozamykalność - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury średniej - przyrost temperatury maksymalnej - zdolność do samozamykalności PN-EN 1366-7 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” Systemy transportowe i ich zamkniecia E Szczelnosc ogniowa, izolacyjnosc ogniowa, natezenie promieniowania, samozamykalnosc, samoczynne zamykanie, funkcja zwalniania samozamykalnosc - utrzymywanie sie plomienia - otwory i pekniecia - zapalenie tamponu z waty bawelnianej - przyrost temperatury sredniej - przyrost temperatury maksymalnej - zdolnosc do samozamykalnosci PN-EN 1366-7 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”","categories":["construction"],"row_index":1132,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Conveyor systems and their closures E Fire integrity, fire insulation, radiation intensity, self-closing ability, automatic closing, release function self-closing ability - sustained flaming - openings and cracks - ignition of the cotton wool pad - mean temperature rise - maximum temperature rise - self-closing capability PN-EN 1366-7 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”"},{"_id":"6a5a55f19af9f73f38251381","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Ściany działowe E","test_object_en":"Partition walls E","methodology":"Szczelność ogniowa, izolacyjność ogniowa, natężenie promieniowania, odporność na oddziaływania mechaniczne - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury średniej - przyrost temperatury maksymalnej - natężenie promieniowania - deformacja + Także za pomocą wyposażenia producenta","methodology_en":"Fire integrity, fire insulation, radiation intensity, resistance to mechanical impact - sustained flaming - openings and cracks - ignition of the cotton wool pad - mean temperature rise - maximum temperature rise - radiation intensity - deformation + Also using the manufacturer's equipment","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność ogniowa, izolacyjność ogniowa, natężenie promieniowania, odporność na oddziaływania mechaniczne - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury średniej - przyrost temperatury maksymalnej - natężenie promieniowania - deformacja + Także za pomocą wyposażenia producenta","reference":"PN-EN 1364-1 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” PN-EN 15254-2 „N” PN-EN 15254-5 „N”","norm_bases":["PN-EN 1364-1 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” PN-EN 15254-2 „N” PN-EN 15254-5 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ściany działowe E Szczelność ogniowa, izolacyjność ogniowa, natężenie promieniowania, odporność na oddziaływania mechaniczne - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury średniej - przyrost temperatury maksymalnej - natężenie promieniowania - deformacja + Także za pomocą wyposażenia producenta PN-EN 1364-1 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” PN-EN 15254-2 „N” PN-EN 15254-5 „N” Sciany dzialowe E Szczelnosc ogniowa, izolacyjnosc ogniowa, natezenie promieniowania, odpornosc na oddzialywania mechaniczne - utrzymywanie sie plomienia - otwory i pekniecia - zapalenie tamponu z waty bawelnianej - przyrost temperatury sredniej - przyrost temperatury maksymalnej - natezenie promieniowania - deformacja + Takze za pomoca wyposazenia producenta PN-EN 1364-1 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” PN-EN 15254-2 „N” PN-EN 15254-5 „N”","categories":["construction"],"row_index":1133,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Partition walls E Fire integrity, fire insulation, radiation intensity, resistance to mechanical impact - sustained flaming - openings and cracks - ignition of the cotton wool pad - mean temperature rise - maximum temperature rise - radiation intensity - deformation + Also using the manufacturer's equipment PN-EN 1364-1 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” PN-EN 15254-2 „N” PN-EN 15254-5 „N”","search_zh":"隔墙 E PN-EN 1364-1 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” PN-EN 15254-2 „N” PN-EN 15254-5 „N”","test_object_zh":"隔墙 E"},{"_id":"6a5a55f19af9f73f38251382","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Ściany kurtynowe E","test_object_en":"Curtain walls E","methodology":"Szczelność ogniowa, izolacyjność ogniowa, natężenie promieniowania - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury średniej - przyrost temperatury maksymalnej - natężenie promieniowania - deformacja + Także za pomocą wyposażenia producenta","methodology_en":"Fire integrity, fire insulation, radiation intensity - sustained flaming - openings and cracks - ignition of the cotton wool pad - mean temperature rise - maximum temperature rise - radiation intensity - deformation + Also using the manufacturer's equipment","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność ogniowa, izolacyjność ogniowa, natężenie promieniowania - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury średniej - przyrost temperatury maksymalnej - natężenie promieniowania - deformacja + Także za pomocą wyposażenia producenta","reference":"PN-EN 1364-3 „N” PN-EN 1364-4 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”","norm_bases":["PN-EN 1364-3 „N” PN-EN 1364-4 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ściany kurtynowe E Szczelność ogniowa, izolacyjność ogniowa, natężenie promieniowania - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury średniej - przyrost temperatury maksymalnej - natężenie promieniowania - deformacja + Także za pomocą wyposażenia producenta PN-EN 1364-3 „N” PN-EN 1364-4 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” Sciany kurtynowe E Szczelnosc ogniowa, izolacyjnosc ogniowa, natezenie promieniowania - utrzymywanie sie plomienia - otwory i pekniecia - zapalenie tamponu z waty bawelnianej - przyrost temperatury sredniej - przyrost temperatury maksymalnej - natezenie promieniowania - deformacja + Takze za pomoca wyposazenia producenta PN-EN 1364-3 „N” PN-EN 1364-4 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”","categories":["construction"],"row_index":1134,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Curtain walls E Fire integrity, fire insulation, radiation intensity - sustained flaming - openings and cracks - ignition of the cotton wool pad - mean temperature rise - maximum temperature rise - radiation intensity - deformation + Also using the manufacturer's equipment PN-EN 1364-3 „N” PN-EN 1364-4 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N”"},{"_id":"6a5a55f19af9f73f38251383","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Ściany nośne E","test_object_en":"Loadbearing walls E","methodology":"Nośność ogniowa R - maksymalne obciążenie 500T, szczelność ogniowa, izolacyjność ogniowa, natężenie promieniowania, odporność na oddziaływania mechaniczne - deformacja C - prędkość deformacji dC/dt - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury średniej - przyrost temperatury maksymalnej - natężenie promieniowania - efekt oddziaływania mechanicznego - deformacja","methodology_en":"Loadbearing capacity R - maximum load 500T, integrity, insulation, radiation, resistance to mechanical impact - deformation C - rate of deformation dC/dt - sustained flaming - openings and cracks - ignition of the cotton wool pad - mean temperature rise - maximum temperature rise - radiation intensity - effect of mechanical impact - deformation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność ogniowa R - maksymalne obciążenie 500T, szczelność ogniowa, izolacyjność ogniowa, natężenie promieniowania, odporność na oddziaływania mechaniczne - deformacja C - prędkość deformacji dC/dt - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury średniej - przyrost temperatury maksymalnej - natężenie promieniowania - efekt oddziaływania mechanicznego - deformacja","reference":"PN-EN 1365-1 „N” PN-EN 1363-2 „N” PN-EN 1363-1 „N”","norm_bases":["PN-EN 1365-1 „N” PN-EN 1363-2 „N” PN-EN 1363-1 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ściany nośne E Nośność ogniowa R - maksymalne obciążenie 500T, szczelność ogniowa, izolacyjność ogniowa, natężenie promieniowania, odporność na oddziaływania mechaniczne - deformacja C - prędkość deformacji dC/dt - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury średniej - przyrost temperatury maksymalnej - natężenie promieniowania - efekt oddziaływania mechanicznego - deformacja PN-EN 1365-1 „N” PN-EN 1363-2 „N” PN-EN 1363-1 „N” Sciany nosne E Nosnosc ogniowa R - maksymalne obciazenie 500T, szczelnosc ogniowa, izolacyjnosc ogniowa, natezenie promieniowania, odpornosc na oddzialywania mechaniczne - deformacja C - predkosc deformacji dC/dt - utrzymywanie sie plomienia - otwory i pekniecia - zapalenie tamponu z waty bawelnianej - przyrost temperatury sredniej - przyrost temperatury maksymalnej - natezenie promieniowania - efekt oddzialywania mechanicznego - deformacja PN-EN 1365-1 „N” PN-EN 1363-2 „N” PN-EN 1363-1 „N”","categories":["construction"],"row_index":1135,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Loadbearing walls E Loadbearing capacity R - maximum load 500T, integrity, insulation, radiation, resistance to mechanical impact - deformation C - rate of deformation dC/dt - sustained flaming - openings and cracks - ignition of the cotton wool pad - mean temperature rise - maximum temperature rise - radiation intensity - effect of mechanical impact - deformation PN-EN 1365-1 „N” PN-EN 1363-2 „N” PN-EN 1363-1 „N”"},{"_id":"6a5a55f19af9f73f38251384","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Uszczelnienia przejść instalacyjnych E","test_object_en":"Penetration seals E","methodology":"Szczelność ogniowa, izolacyjność ogniowa - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury maksymalnej","methodology_en":"Fire integrity, fire insulation - sustained flaming - openings and cracks - ignition of the cotton wool pad - maximum temperature rise","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność ogniowa, izolacyjność ogniowa - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury maksymalnej","reference":"PN-EN 1366-3 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350454-00-1104 „N”","norm_bases":["PN-EN 1366-3 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350454-00-1104 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Uszczelnienia przejść instalacyjnych E Szczelność ogniowa, izolacyjność ogniowa - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury maksymalnej PN-EN 1366-3 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350454-00-1104 „N” Uszczelnienia przejsc instalacyjnych E Szczelnosc ogniowa, izolacyjnosc ogniowa - utrzymywanie sie plomienia - otwory i pekniecia - zapalenie tamponu z waty bawelnianej - przyrost temperatury maksymalnej PN-EN 1366-3 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350454-00-1104 „N”","categories":["construction"],"row_index":1136,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Penetration seals E Fire integrity, fire insulation - sustained flaming - openings and cracks - ignition of the cotton wool pad - maximum temperature rise PN-EN 1366-3 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350454-00-1104 „N”"},{"_id":"6a5a55f19af9f73f38251385","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Uszczelnienia złączy liniowych E","test_object_en":"Linear joint seals E","methodology":"Szczelność ogniowa, izolacyjność ogniowa - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury maksymalnej - zdolność przemieszczania","methodology_en":"Fire integrity, fire insulation - sustained flaming - openings and cracks - ignition of the cotton wool pad - maximum temperature rise - displacement capability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność ogniowa, izolacyjność ogniowa - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury maksymalnej - zdolność przemieszczania","reference":"PN-EN 1366-4 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350141-00-1106 „N”","norm_bases":["PN-EN 1366-4 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350141-00-1106 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Uszczelnienia złączy liniowych E Szczelność ogniowa, izolacyjność ogniowa - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu z waty bawełnianej - przyrost temperatury maksymalnej - zdolność przemieszczania PN-EN 1366-4 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350141-00-1106 „N” Uszczelnienia zlaczy liniowych E Szczelnosc ogniowa, izolacyjnosc ogniowa - utrzymywanie sie plomienia - otwory i pekniecia - zapalenie tamponu z waty bawelnianej - przyrost temperatury maksymalnej - zdolnosc przemieszczania PN-EN 1366-4 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350141-00-1106 „N”","categories":["construction"],"row_index":1137,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Linear joint seals E Fire integrity, fire insulation - sustained flaming - openings and cracks - ignition of the cotton wool pad - maximum temperature rise - displacement capability PN-EN 1366-4 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350141-00-1106 „N”"},{"_id":"6a5a55f19af9f73f38251386","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wentylatory oddymiające E","test_object_en":"Smoke extraction fans E","methodology":"Skuteczność działania w wysokiej temperaturze - skuteczność działania w wysokiej temperaturze","methodology_en":"High temperature performance - high temperature performance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność działania w wysokiej temperaturze - skuteczność działania w wysokiej temperaturze","reference":"PN-EN 12101-3","norm_bases":["PN-EN 12101-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wentylatory oddymiające E Skuteczność działania w wysokiej temperaturze - skuteczność działania w wysokiej temperaturze PN-EN 12101-3 Wentylatory oddymiajace E Skutecznosc dzialania w wysokiej temperaturze - skutecznosc dzialania w wysokiej temperaturze PN-EN 12101-3","categories":["other"],"row_index":1138,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Smoke extraction fans E High temperature performance - high temperature performance PN-EN 12101-3"},{"_id":"6a5a55f19af9f73f38251387","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wydzielenia pustek E","test_object_en":"Void formers E","methodology":"Szczelność ogniowa, izolacyjność ogniowa - utrzymywanie się płomienia - zapalenie tamponu z waty bawełnianej - przyrost temperatury maksymalnej - deformacja","methodology_en":"Fire integrity, fire insulation - sustained flaming - ignition of the cotton wool pad - maximum temperature rise - deformation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność ogniowa, izolacyjność ogniowa - utrzymywanie się płomienia - zapalenie tamponu z waty bawełnianej - przyrost temperatury maksymalnej - deformacja","reference":"EOTA TR031 „N”","norm_bases":["EOTA TR031 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wydzielenia pustek E Szczelność ogniowa, izolacyjność ogniowa - utrzymywanie się płomienia - zapalenie tamponu z waty bawełnianej - przyrost temperatury maksymalnej - deformacja EOTA TR031 „N” Wydzielenia pustek E Szczelnosc ogniowa, izolacyjnosc ogniowa - utrzymywanie sie plomienia - zapalenie tamponu z waty bawelnianej - przyrost temperatury maksymalnej - deformacja EOTA TR031 „N”","categories":["construction"],"row_index":1139,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Void formers E Fire integrity, fire insulation - sustained flaming - ignition of the cotton wool pad - maximum temperature rise - deformation EOTA TR031 „N”"},{"_id":"6a5a55f19af9f73f38251388","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby budowlane, konstrukcyjne i wykończeniowe E","test_object_en":"Construction, structural and finishing products E","methodology":"Ciepło spalania - wzrost temperatury","methodology_en":"Heat of combustion - temperature rise","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciepło spalania - wzrost temperatury","reference":"PN-EN ISO 1716 „N”","norm_bases":["PN-EN ISO 1716 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby budowlane, konstrukcyjne i wykończeniowe E Ciepło spalania - wzrost temperatury PN-EN ISO 1716 „N” Wyroby budowlane, konstrukcyjne i wykonczeniowe E Cieplo spalania - wzrost temperatury PN-EN ISO 1716 „N”","categories":["construction"],"row_index":1140,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Construction, structural and finishing products E Heat of combustion - temperature rise PN-EN ISO 1716 „N”","search_zh":"建筑、结构与装饰制品 E PN-EN ISO 1716 „N”","test_object_zh":"建筑、结构与装饰制品 E"},{"_id":"6a5a55f19af9f73f38251389","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby budowlane, konstrukcyjne i wykończeniowe E","test_object_en":"Construction, structural and finishing products E","methodology":"Niepalność - względny ubytek masy - przyrost temperatury - czas palenia","methodology_en":"Non-combustibility - relative mass loss - temperature rise - duration of flaming","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Niepalność - względny ubytek masy - przyrost temperatury - czas palenia","reference":"PN-EN ISO 1182 „N”","norm_bases":["PN-EN ISO 1182 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby budowlane, konstrukcyjne i wykończeniowe E Niepalność - względny ubytek masy - przyrost temperatury - czas palenia PN-EN ISO 1182 „N” Wyroby budowlane, konstrukcyjne i wykonczeniowe E Niepalnosc - wzgledny ubytek masy - przyrost temperatury - czas palenia PN-EN ISO 1182 „N”","categories":["construction"],"row_index":1141,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Construction, structural and finishing products E Non-combustibility - relative mass loss - temperature rise - duration of flaming PN-EN ISO 1182 „N”","search_zh":"建筑、结构与装饰制品 E PN-EN ISO 1182 „N”","test_object_zh":"建筑、结构与装饰制品 E"},{"_id":"6a5a55f19af9f73f3825138a","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby budowlane, konstrukcyjne i wykończeniowe E","test_object_en":"Construction, structural and finishing products E","methodology":"Wydzielanie ciepła, wydzielanie dymu Metoda kalorymetru stożkowego - wydzielanie ciepła - wydzielanie dymu - czas do zapalenia","methodology_en":"Heat release, smoke release Cone calorimeter method - heat release - smoke release - time to ignition","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wydzielanie ciepła, wydzielanie dymu Metoda kalorymetru stożkowego - wydzielanie ciepła - wydzielanie dymu - czas do zapalenia","reference":"ISO 5660-1","norm_bases":["ISO 5660-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby budowlane, konstrukcyjne i wykończeniowe E Wydzielanie ciepła, wydzielanie dymu Metoda kalorymetru stożkowego - wydzielanie ciepła - wydzielanie dymu - czas do zapalenia ISO 5660-1 Wyroby budowlane, konstrukcyjne i wykonczeniowe E Wydzielanie ciepla, wydzielanie dymu Metoda kalorymetru stozkowego - wydzielanie ciepla - wydzielanie dymu - czas do zapalenia ISO 5660-1","categories":["construction"],"row_index":1142,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Construction, structural and finishing products E Heat release, smoke release Cone calorimeter method - heat release - smoke release - time to ignition ISO 5660-1","search_zh":"建筑、结构与装饰制品 E ISO 5660-1","test_object_zh":"建筑、结构与装饰制品 E"},{"_id":"6a5a55f19af9f73f3825138b","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby budowlane, konstrukcyjne i wykończeniowe E","test_object_en":"Construction, structural and finishing products E","methodology":"Zapalność metodą pojedynczego płomienia - zasięg płomienia - występowanie płonących kropli","methodology_en":"Ignitability by the single-flame method - range of flame - occurrence of flaming droplets","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zapalność metodą pojedynczego płomienia - zasięg płomienia - występowanie płonących kropli","reference":"PN-EN ISO 11925-2 „N”","norm_bases":["PN-EN ISO 11925-2 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby budowlane, konstrukcyjne i wykończeniowe E Zapalność metodą pojedynczego płomienia - zasięg płomienia - występowanie płonących kropli PN-EN ISO 11925-2 „N” Wyroby budowlane, konstrukcyjne i wykonczeniowe E Zapalnosc metoda pojedynczego plomienia - zasieg plomienia - wystepowanie plonacych kropli PN-EN ISO 11925-2 „N”","categories":["construction"],"row_index":1143,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Construction, structural and finishing products E Ignitability by the single-flame method - range of flame - occurrence of flaming droplets PN-EN ISO 11925-2 „N”","search_zh":"建筑、结构与装饰制品 E PN-EN ISO 11925-2 „N”","test_object_zh":"建筑、结构与装饰制品 E"},{"_id":"6a5a55f19af9f73f3825138c","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby budowlane termopęczniejące E","test_object_en":"Intumescent construction products E","methodology":"Ciśnienie pęcznienia","methodology_en":"Swelling pressure","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciśnienie pęcznienia","reference":"EOTA TR024 „N”","norm_bases":["EOTA TR024 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby budowlane termopęczniejące E Ciśnienie pęcznienia EOTA TR024 „N” Wyroby budowlane termopeczniejace E Cisnienie pecznienia EOTA TR024 „N”","categories":["construction"],"row_index":1144,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Intumescent construction products E Swelling pressure EOTA TR024 „N”"},{"_id":"6a5a55f19af9f73f3825138d","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby budowlane termopęczniejące E","test_object_en":"Intumescent construction products E","methodology":"Wysokość spęcznienia","methodology_en":"Swelling height","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wysokość spęcznienia","reference":"EOTA TR024 „N”","norm_bases":["EOTA TR024 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby budowlane termopęczniejące E Wysokość spęcznienia EOTA TR024 „N” Wyroby budowlane termopeczniejace E Wysokosc specznienia EOTA TR024 „N”","categories":["construction"],"row_index":1145,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Intumescent construction products E Swelling height EOTA TR024 „N”"},{"_id":"6a5a55f19af9f73f3825138e","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby budowlane, konstrukcyjne i wykończeniowe z wyłączeniem posadzek E","test_object_en":"Construction, structural and finishing products excluding floorings E","methodology":"Wydzielanie ciepła, wydzielanie dymu, boczne rozprzestrzenianie płomienia, kapanie i odpadanie - wydzielanie ciepła - wydzielanie dymu - spadające płonące fragmenty/krople - rozprzestrzenianie płomienia - płomień na powierzchni","methodology_en":"Heat release, smoke release, lateral flame spread, dripping and falling off - heat release - smoke release - falling flaming fragments/droplets - flame spread - flame on the surface","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wydzielanie ciepła, wydzielanie dymu, boczne rozprzestrzenianie płomienia, kapanie i odpadanie - wydzielanie ciepła - wydzielanie dymu - spadające płonące fragmenty/krople - rozprzestrzenianie płomienia - płomień na powierzchni","reference":"PN-EN 13823 „N”","norm_bases":["PN-EN 13823 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby budowlane, konstrukcyjne i wykończeniowe z wyłączeniem posadzek E Wydzielanie ciepła, wydzielanie dymu, boczne rozprzestrzenianie płomienia, kapanie i odpadanie - wydzielanie ciepła - wydzielanie dymu - spadające płonące fragmenty/krople - rozprzestrzenianie płomienia - płomień na powierzchni PN-EN 13823 „N” Wyroby budowlane, konstrukcyjne i wykonczeniowe z wylaczeniem posadzek E Wydzielanie ciepla, wydzielanie dymu, boczne rozprzestrzenianie plomienia, kapanie i odpadanie - wydzielanie ciepla - wydzielanie dymu - spadajace plonace fragmenty/krople - rozprzestrzenianie plomienia - plomien na powierzchni PN-EN 13823 „N”","categories":["environment","construction"],"row_index":1146,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Construction, structural and finishing products excluding floorings E Heat release, smoke release, lateral flame spread, dripping and falling off - heat release - smoke release - falling flaming fragments/droplets - flame spread - flame on the surface PN-EN 13823 „N”"},{"_id":"6a5a55f19af9f73f3825138f","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Wyroby budowlane, konstrukcyjne i wykończeniowe z wyłączeniem posadzek E","test_object_en":"Construction, structural and finishing products excluding floorings E","methodology":"Wydzielanie: ciepła, dymu, CO, CO2; czas do rozgorzenia - wydzielanie ciepła - wydzielanie dymu - spadające płonące fragmenty/krople - rozprzestrzenienie płomienia - płomień na powierzchni - czas do rozgorzenia","methodology_en":"Release of: heat, smoke, CO, CO2; time to flashover - heat release - smoke release - falling flaming fragments/droplets - flame spread - flame on the surface - time to flashover","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wydzielanie: ciepła, dymu, CO, CO2; czas do rozgorzenia - wydzielanie ciepła - wydzielanie dymu - spadające płonące fragmenty/krople - rozprzestrzenienie płomienia - płomień na powierzchni - czas do rozgorzenia","reference":"PN-EN 14390","norm_bases":["PN-EN 14390"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby budowlane, konstrukcyjne i wykończeniowe z wyłączeniem posadzek E Wydzielanie: ciepła, dymu, CO, CO2; czas do rozgorzenia - wydzielanie ciepła - wydzielanie dymu - spadające płonące fragmenty/krople - rozprzestrzenienie płomienia - płomień na powierzchni - czas do rozgorzenia PN-EN 14390 Wyroby budowlane, konstrukcyjne i wykonczeniowe z wylaczeniem posadzek E Wydzielanie: ciepla, dymu, CO, CO2; czas do rozgorzenia - wydzielanie ciepla - wydzielanie dymu - spadajace plonace fragmenty/krople - rozprzestrzenienie plomienia - plomien na powierzchni - czas do rozgorzenia PN-EN 14390","categories":["construction"],"row_index":1147,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Construction, structural and finishing products excluding floorings E Release of: heat, smoke, CO, CO2; time to flashover - heat release - smoke release - falling flaming fragments/droplets - flame spread - flame on the surface - time to flashover PN-EN 14390"},{"_id":"6a5a55f19af9f73f38251390","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zabezpieczenia ogniochronne elementów betonowych E","test_object_en":"Fire protection of concrete elements E","methodology":"Skuteczność ogniochronna zabezpieczenia ogniochronnego elementów betonowych - czas osiągnięcia temperatury krytycznej i deformacji","methodology_en":"Fire protection effectiveness of the fire protection of concrete elements - time to reach the critical temperature and deformation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność ogniochronna zabezpieczenia ogniochronnego elementów betonowych - czas osiągnięcia temperatury krytycznej i deformacji","reference":"PN-ENV 13381-3 „N” PN-EN 13381-3 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350140-00-1106 „N” EAD 350142-00-1106 „N”","norm_bases":["PN-ENV 13381-3 „N” PN-EN 13381-3 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350140-00-1106 „N” EAD 350142-00-1106 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zabezpieczenia ogniochronne elementów betonowych E Skuteczność ogniochronna zabezpieczenia ogniochronnego elementów betonowych - czas osiągnięcia temperatury krytycznej i deformacji PN-ENV 13381-3 „N” PN-EN 13381-3 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350140-00-1106 „N” EAD 350142-00-1106 „N” Zabezpieczenia ogniochronne elementow betonowych E Skutecznosc ogniochronna zabezpieczenia ogniochronnego elementow betonowych - czas osiagniecia temperatury krytycznej i deformacji PN-ENV 13381-3 „N” PN-EN 13381-3 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350140-00-1106 „N” EAD 350142-00-1106 „N”","categories":["construction"],"row_index":1148,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fire protection of concrete elements E Fire protection effectiveness of the fire protection of concrete elements - time to reach the critical temperature and deformation PN-ENV 13381-3 „N” PN-EN 13381-3 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350140-00-1106 „N” EAD 350142-00-1106 „N”"},{"_id":"6a5a55f19af9f73f38251391","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zabezpieczenia ogniochronne elementów drewnianych E","test_object_en":"Fire protection of timber elements E","methodology":"Skuteczność ogniochronna zabezpieczenia ogniochronnego elementów drewnianych - czas osiągnięcia temperatury krytycznej i deformacji","methodology_en":"Fire protection effectiveness of the fire protection of timber elements - time to reach the critical temperature and deformation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność ogniochronna zabezpieczenia ogniochronnego elementów drewnianych - czas osiągnięcia temperatury krytycznej i deformacji","reference":"PN-ENV 13381-7 „N” PN-EN 13381-7 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350140-00-1106 „N” EAD 350142-00-1106 „N”","norm_bases":["PN-ENV 13381-7 „N” PN-EN 13381-7 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350140-00-1106 „N” EAD 350142-00-1106 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zabezpieczenia ogniochronne elementów drewnianych E Skuteczność ogniochronna zabezpieczenia ogniochronnego elementów drewnianych - czas osiągnięcia temperatury krytycznej i deformacji PN-ENV 13381-7 „N” PN-EN 13381-7 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350140-00-1106 „N” EAD 350142-00-1106 „N” Zabezpieczenia ogniochronne elementow drewnianych E Skutecznosc ogniochronna zabezpieczenia ogniochronnego elementow drewnianych - czas osiagniecia temperatury krytycznej i deformacji PN-ENV 13381-7 „N” PN-EN 13381-7 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350140-00-1106 „N” EAD 350142-00-1106 „N”","categories":["other"],"row_index":1149,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fire protection of timber elements E Fire protection effectiveness of the fire protection of timber elements - time to reach the critical temperature and deformation PN-ENV 13381-7 „N” PN-EN 13381-7 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350140-00-1106 „N” EAD 350142-00-1106 „N”"},{"_id":"6a5a55f19af9f73f38251392","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zabezpieczenia ogniochronne elementów stalowych E","test_object_en":"Fire protection of steel elements E","methodology":"Skuteczność ogniochronna zabezpieczenia ogniochronnego elementów stalowych - czas osiągnięcia temperatury krytycznej i deformacji","methodology_en":"Fire protection effectiveness of the fire protection of steel elements - time to reach the critical temperature and deformation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność ogniochronna zabezpieczenia ogniochronnego elementów stalowych - czas osiągnięcia temperatury krytycznej i deformacji","reference":"PN-EN 13381-8 „N” PN-ENV 13381-4 „N” PN-EN 13381-4 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350402-00-1106 „N” EAD 350140-00-1106 „N” EAD 350142-00-1106 „N”","norm_bases":["PN-EN 13381-8 „N” PN-ENV 13381-4 „N” PN-EN 13381-4 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350402-00-1106 „N” EAD 350140-00-1106 „N” EAD 350142-00-1106 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zabezpieczenia ogniochronne elementów stalowych E Skuteczność ogniochronna zabezpieczenia ogniochronnego elementów stalowych - czas osiągnięcia temperatury krytycznej i deformacji PN-EN 13381-8 „N” PN-ENV 13381-4 „N” PN-EN 13381-4 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350402-00-1106 „N” EAD 350140-00-1106 „N” EAD 350142-00-1106 „N” Zabezpieczenia ogniochronne elementow stalowych E Skutecznosc ogniochronna zabezpieczenia ogniochronnego elementow stalowych - czas osiagniecia temperatury krytycznej i deformacji PN-EN 13381-8 „N” PN-ENV 13381-4 „N” PN-EN 13381-4 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350402-00-1106 „N” EAD 350140-00-1106 „N” EAD 350142-00-1106 „N”","categories":["materials"],"row_index":1150,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fire protection of steel elements E Fire protection effectiveness of the fire protection of steel elements - time to reach the critical temperature and deformation PN-EN 13381-8 „N” PN-ENV 13381-4 „N” PN-EN 13381-4 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350402-00-1106 „N” EAD 350140-00-1106 „N” EAD 350142-00-1106 „N”"},{"_id":"6a5a55f19af9f73f38251393","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zabezpieczenia ogniochronne płaskich elementów zespolonych z betonu z blachą profilowaną E","test_object_en":"Fire protection of flat composite elements of concrete with profiled sheeting E","methodology":"Skuteczność ogniochronna zabezpieczenia ogniochronnego płaskich elementów zespolonych z betonu z blachą profilowaną - czas osiągnięcia temperatury krytycznej i deformacji","methodology_en":"Fire protection effectiveness of the fire protection of flat composite elements of concrete with profiled steel sheeting - time to reach the critical temperature and deformation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność ogniochronna zabezpieczenia ogniochronnego płaskich elementów zespolonych z betonu z blachą profilowaną - czas osiągnięcia temperatury krytycznej i deformacji","reference":"PN-EN 13381-5 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350140-00-1106 „N” EAD 350142-00-1106 „N”","norm_bases":["PN-EN 13381-5 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350140-00-1106 „N” EAD 350142-00-1106 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zabezpieczenia ogniochronne płaskich elementów zespolonych z betonu z blachą profilowaną E Skuteczność ogniochronna zabezpieczenia ogniochronnego płaskich elementów zespolonych z betonu z blachą profilowaną - czas osiągnięcia temperatury krytycznej i deformacji PN-EN 13381-5 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350140-00-1106 „N” EAD 350142-00-1106 „N” Zabezpieczenia ogniochronne plaskich elementow zespolonych z betonu z blacha profilowana E Skutecznosc ogniochronna zabezpieczenia ogniochronnego plaskich elementow zespolonych z betonu z blacha profilowana - czas osiagniecia temperatury krytycznej i deformacji PN-EN 13381-5 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350140-00-1106 „N” EAD 350142-00-1106 „N”","categories":["construction"],"row_index":1151,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fire protection of flat composite elements of concrete with profiled sheeting E Fire protection effectiveness of the fire protection of flat composite elements of concrete with profiled steel sheeting - time to reach the critical temperature and deformation PN-EN 13381-5 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350140-00-1106 „N” EAD 350142-00-1106 „N”"},{"_id":"6a5a55f19af9f73f38251394","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zabezpieczenia ogniochronne słupów stalowych o przekroju zamkniętym wypełnionych betonem E","test_object_en":"Fire protection of concrete-filled hollow section steel columns E","methodology":"Skuteczność ogniochronna zabezpieczenia ogniochronnego słupów stalowych o przekroju zamkniętym wypełnionych betonem - czas osiągnięcia temperatury krytycznej i deformacji","methodology_en":"Fire protection effectiveness of the fire protection of concrete-filled hollow section steel columns - time to reach the critical temperature and deformation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność ogniochronna zabezpieczenia ogniochronnego słupów stalowych o przekroju zamkniętym wypełnionych betonem - czas osiągnięcia temperatury krytycznej i deformacji","reference":"PN-EN 13381-6 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350140-00-1106 „N” EAD 350142-00-1106 „N”","norm_bases":["PN-EN 13381-6 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350140-00-1106 „N” EAD 350142-00-1106 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zabezpieczenia ogniochronne słupów stalowych o przekroju zamkniętym wypełnionych betonem E Skuteczność ogniochronna zabezpieczenia ogniochronnego słupów stalowych o przekroju zamkniętym wypełnionych betonem - czas osiągnięcia temperatury krytycznej i deformacji PN-EN 13381-6 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350140-00-1106 „N” EAD 350142-00-1106 „N” Zabezpieczenia ogniochronne slupow stalowych o przekroju zamknietym wypelnionych betonem E Skutecznosc ogniochronna zabezpieczenia ogniochronnego slupow stalowych o przekroju zamknietym wypelnionych betonem - czas osiagniecia temperatury krytycznej i deformacji PN-EN 13381-6 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350140-00-1106 „N” EAD 350142-00-1106 „N”","categories":["materials","construction"],"row_index":1152,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fire protection of concrete-filled hollow section steel columns E Fire protection effectiveness of the fire protection of concrete-filled hollow section steel columns - time to reach the critical temperature and deformation PN-EN 13381-6 „N” PN-EN 1363-1 „N” PN-EN 1363-2 „N” EAD 350140-00-1106 „N” EAD 350142-00-1106 „N”"},{"_id":"6a5a55f19af9f73f38251395","lab_id":"69ad52a3de79e566650fb0cf","country":"PL","accr_number":"AB 023","accr_body":"PCA","test_object":"Zasłony, kotary, kurtyny, folie, tkaniny namiotowe, markizy E","test_object_en":"Curtains, drapes, drop curtains, films, tent fabrics, awnings E","methodology":"Stopień palności wyrobów elastycznych - zasięg rozprzestrzenienia płomieni - czas do zapalenia","methodology_en":"Degree of flammability of flexible products - flame spread extent - time to ignition","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stopień palności wyrobów elastycznych - zasięg rozprzestrzenienia płomieni - czas do zapalenia","reference":"PN-EN ISO 6941 PN-EN ISO 6940","norm_bases":["PN-EN ISO 6941 PN-EN ISO 6940"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zasłony, kotary, kurtyny, folie, tkaniny namiotowe, markizy E Stopień palności wyrobów elastycznych - zasięg rozprzestrzenienia płomieni - czas do zapalenia PN-EN ISO 6941 PN-EN ISO 6940 Zaslony, kotary, kurtyny, folie, tkaniny namiotowe, markizy E Stopien palnosci wyrobow elastycznych - zasieg rozprzestrzenienia plomieni - czas do zapalenia PN-EN ISO 6941 PN-EN ISO 6940","categories":["other"],"row_index":1153,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Curtains, drapes, drop curtains, films, tent fabrics, awnings E Degree of flammability of flexible products - flame spread extent - time to ignition PN-EN ISO 6941 PN-EN ISO 6940"}],"has_pdf":true}