{"lab":{"_id":"69ad52a3de79e566650fb0c3","accr_number":"AB 012","country":"PL","accr_body":"PCA","address":"LABORATORIUM BADAWCZE, ul. Ratuszowa 11, 03-450 Warszawa","categories":["electronics","environment"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":23,"name":"ELTEST M. JEWTUCH Spółka Jawna","parse_status":"parsed","parse_version":3,"pdf_files":["AB_012.pdf"],"scope_summary":"","search_text":"eltest m. jewtuch spółka jawna laboratorium badawcze, ul. ratuszowa 11, 03-450 warszawa other pharma electronics materials metrology environment construction water","status":"active","updated_at":"2026-03-08T14:50:01.470Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:01.470Z","parse_date":"2026-07-17T16:18:56.926Z","parse_source":"m5-mistral-qa","email_confidence":"high","email_mx":true,"email_source":"https://www.eltest.pl/kontakt/","fields_of_testing":[{"codes":"E/6; E/7; E13; E/14; E16; E17; E/25; E/50;E/53; E/54","pl":"medycznego, zabawek, sprzętu rekreacyjnego wyrobów i wyposażenia telekomunikacyjnego, wyrobów i wyposażenia elektronicznego, maszyn i urządzeń, wyposażenia optycznego, wyrobów innych","en":"Electric and electronic tests of electrical products and equipment, software, medical equipment, toys, leisure equipment, telecommunication and electronic products and equipment, machinery and devices, optical equipment, other products"},{"codes":"N/6; N/7; N13; N/14; N16; N17; N25; N/53; N/54","pl":"Badania właściwości fizycznych wyrobów i wyposażenia elektrycznego, oprogramowania, wyposażenia medycznego, wyrobów i wyposażenia telekomunikacyjnego, wyrobów i wyposażenia elektronicznego, maszyn i urządzeń, wyposażenia optycznego, wyrobów innych, zabawek","en":"Tests of physical properties of electrical products and equipment, software, medical equipment, telecommunication and electronic products and equipment, machinery and devices, optical equipment, other products, toys Badania kompatybilności elektromagnetycznej (EMC) wyrobów i wyposażenia elektrycznego, wyposażenia"},{"codes":"F/6; F13; F/14; F16; F17; F25; F/53; F/54","pl":"medycznego, wyrobów i wyposażenia telekomunikacyjnego, wyrobów i wyposażenia elektronicznego maszyn i urządzeń, wyposażenia optycznego, wyrobów innych, zabawek","en":"Electromagnetic compatibility (EMC) tests of electrical products and equipment, medical equipment, telecommunication and electronic products and equipment, machinery and devices, optical equipment, other products, toys"}],"issue":{"no":"29","date":"05.12.2025"},"map_coord":[52.258341,21.032331],"map_geo":"nominatim-street","has_en":true,"category_counts":{"other":13,"electronics":10,"environment":2,"materials":1,"construction":1},"category_scores":{"other":6.26,"electronics":3.7,"environment":0.15,"materials":0.04,"construction":0.04},"has_zh":true},"methods":[{"_id":"6a5a55f09af9f73f38250e71","lab_id":"69ad52a3de79e566650fb0c3","country":"PL","accr_number":"AB 012","accr_body":"PCA","test_object":"E Urządzenia techniki fonicznej/ wizyjnej, informatycznej i telekomunikacyjnej","test_object_en":"E Audio/video, information technology and telecommunication equipment","methodology":"Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania","methodology_en":"Characteristics and properties for the assessment of safety in use","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania","reference":"Normy","norm_bases":["Normy"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"E Urządzenia techniki fonicznej/ wizyjnej, informatycznej i telekomunikacyjnej Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania Normy E Urzadzenia techniki fonicznej/ wizyjnej, informatycznej i telekomunikacyjnej Cechy i wlasciwosci dla potrzeb oceny bezpieczenstwa uzytkowania Normy","categories":["other"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"E Audio/video, information technology and telecommunication equipment Characteristics and properties for the assessment of safety in use Normy","methodology_zh":"用于使用安全性评定的特征与性能","search_zh":"用于使用安全性评定的特征与性能 Normy"},{"_id":"6a5a55f09af9f73f38250e72","lab_id":"69ad52a3de79e566650fb0c3","country":"PL","accr_number":"AB 012","accr_body":"PCA","test_object":"E Elektryczny sprzęt do użytku domowego i podobnego","test_object_en":"E Electrical appliances for household and similar use","methodology":"Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania","methodology_en":"Characteristics and properties for the assessment of safety in use","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania","reference":"Normy","norm_bases":["Normy"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"E Elektryczny sprzęt do użytku domowego i podobnego Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania Normy E Elektryczny sprzet do uzytku domowego i podobnego Cechy i wlasciwosci dla potrzeb oceny bezpieczenstwa uzytkowania Normy","categories":["other"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"E Electrical appliances for household and similar use Characteristics and properties for the assessment of safety in use Normy","methodology_zh":"用于使用安全性评定的特征与性能","search_zh":"用于使用安全性评定的特征与性能 Normy"},{"_id":"6a5a55f09af9f73f38250e73","lab_id":"69ad52a3de79e566650fb0c3","country":"PL","accr_number":"AB 012","accr_body":"PCA","test_object":"E Medyczne urządzenia elektryczne","test_object_en":"E Medical electrical equipment","methodology":"Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania","methodology_en":"Characteristics and properties for the assessment of safety in use","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania","reference":"Normy","norm_bases":["Normy"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"E Medyczne urządzenia elektryczne Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania Normy E Medyczne urzadzenia elektryczne Cechy i wlasciwosci dla potrzeb oceny bezpieczenstwa uzytkowania Normy","categories":["other"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"E Medical electrical equipment Characteristics and properties for the assessment of safety in use Normy","methodology_zh":"用于使用安全性评定的特征与性能","search_zh":"用于使用安全性评定的特征与性能 Normy"},{"_id":"6a5a55f09af9f73f38250e74","lab_id":"69ad52a3de79e566650fb0c3","country":"PL","accr_number":"AB 012","accr_body":"PCA","test_object":"E Zasilacze niskiego napięcia prądu stałego","test_object_en":"E Low-voltage direct current power supplies","methodology":"Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania","methodology_en":"Characteristics and properties for the assessment of safety in use","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania","reference":"Normy","norm_bases":["Normy"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"E Zasilacze niskiego napięcia prądu stałego Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania Normy E Zasilacze niskiego napiecia pradu stalego Cechy i wlasciwosci dla potrzeb oceny bezpieczenstwa uzytkowania Normy","categories":["other"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"E Low-voltage direct current power supplies Characteristics and properties for the assessment of safety in use Normy","methodology_zh":"用于使用安全性评定的特征与性能","search_zh":"用于使用安全性评定的特征与性能 Normy"},{"_id":"6a5a55f09af9f73f38250e75","lab_id":"69ad52a3de79e566650fb0c3","country":"PL","accr_number":"AB 012","accr_body":"PCA","test_object":"E Transformatory mocy, jednostki zasilające i podobne","test_object_en":"E Power transformers, power supply units and similar","methodology":"Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania","methodology_en":"Characteristics and properties for the assessment of safety in use","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania","reference":"Normy","norm_bases":["Normy"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"E Transformatory mocy, jednostki zasilające i podobne Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania Normy E Transformatory mocy, jednostki zasilajace i podobne Cechy i wlasciwosci dla potrzeb oceny bezpieczenstwa uzytkowania Normy","categories":["other"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"E Power transformers, power supply units and similar Characteristics and properties for the assessment of safety in use Normy","methodology_zh":"用于使用安全性评定的特征与性能","search_zh":"用于使用安全性评定的特征与性能 Normy"},{"_id":"6a5a55f09af9f73f38250e76","lab_id":"69ad52a3de79e566650fb0c3","country":"PL","accr_number":"AB 012","accr_body":"PCA","test_object":"E Automatyczne regulatory elektryczne","test_object_en":"E Automatic electrical controls","methodology":"Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania","methodology_en":"Characteristics and properties for the assessment of safety in use","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania","reference":"Normy","norm_bases":["Normy"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"E Automatyczne regulatory elektryczne Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania Normy E Automatyczne regulatory elektryczne Cechy i wlasciwosci dla potrzeb oceny bezpieczenstwa uzytkowania Normy","categories":["other"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"E Automatic electrical controls Characteristics and properties for the assessment of safety in use Normy","methodology_zh":"用于使用安全性评定的特征与性能","search_zh":"用于使用安全性评定的特征与性能 Normy"},{"_id":"6a5a55f09af9f73f38250e77","lab_id":"69ad52a3de79e566650fb0c3","country":"PL","accr_number":"AB 012","accr_body":"PCA","test_object":"E Łączniki do przyrządów","test_object_en":"E Switches for appliances","methodology":"Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania","methodology_en":"Characteristics and properties for the assessment of safety in use","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania","reference":"PN-EN 61058-1 PN-EN IEC 61058-1","norm_bases":["PN-EN 61058-1 PN-EN IEC 61058-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"E Łączniki do przyrządów Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania PN-EN 61058-1 PN-EN IEC 61058-1 E Laczniki do przyrzadow Cechy i wlasciwosci dla potrzeb oceny bezpieczenstwa uzytkowania PN-EN 61058-1 PN-EN IEC 61058-1","categories":["other"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"E Switches for appliances Characteristics and properties for the assessment of safety in use PN-EN 61058-1 PN-EN IEC 61058-1","methodology_zh":"用于使用安全性评定的特征与性能","search_zh":"用于使用安全性评定的特征与性能 PN-EN 61058-1 PN-EN IEC 61058-1"},{"_id":"6a5a55f09af9f73f38250e78","lab_id":"69ad52a3de79e566650fb0c3","country":"PL","accr_number":"AB 012","accr_body":"PCA","test_object":"E Łączniki do stałych instalacji elektrycznych","test_object_en":"E Switches for fixed electrical installations","methodology":"Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania","methodology_en":"Characteristics and properties for the assessment of safety in use","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania","reference":"Normy","norm_bases":["Normy"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"E Łączniki do stałych instalacji elektrycznych Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania Normy E Laczniki do stalych instalacji elektrycznych Cechy i wlasciwosci dla potrzeb oceny bezpieczenstwa uzytkowania Normy","categories":["other"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"E Switches for fixed electrical installations Characteristics and properties for the assessment of safety in use Normy","methodology_zh":"用于使用安全性评定的特征与性能","search_zh":"用于使用安全性评定的特征与性能 Normy"},{"_id":"6a5a55f09af9f73f38250e79","lab_id":"69ad52a3de79e566650fb0c3","country":"PL","accr_number":"AB 012","accr_body":"PCA","test_object":"E Elektryczne przyrządy pomiarowe, automatyka i urządzenia laboratoryjne","test_object_en":"E Electrical measuring instruments, control equipment and laboratory equipment","methodology":"Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania","methodology_en":"Characteristics and properties for the assessment of safety in use","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania","reference":"PN-EN 61010-1","norm_bases":["PN-EN 61010-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"E Elektryczne przyrządy pomiarowe, automatyka i urządzenia laboratoryjne Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania PN-EN 61010-1 E Elektryczne przyrzady pomiarowe, automatyka i urzadzenia laboratoryjne Cechy i wlasciwosci dla potrzeb oceny bezpieczenstwa uzytkowania PN-EN 61010-1","categories":["other"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"E Electrical measuring instruments, control equipment and laboratory equipment Characteristics and properties for the assessment of safety in use PN-EN 61010-1","methodology_zh":"用于使用安全性评定的特征与性能","search_zh":"用于使用安全性评定的特征与性能 PN-EN 61010-1"},{"_id":"6a5a55f09af9f73f38250e7a","lab_id":"69ad52a3de79e566650fb0c3","country":"PL","accr_number":"AB 012","accr_body":"PCA","test_object":"E Przedłużacze zwijane do zastosowań domowych i podobnych","test_object_en":"E Cable reels for household and similar purposes","methodology":"Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania","methodology_en":"Characteristics and properties for the assessment of safety in use","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania","reference":"PN-EN 61242","norm_bases":["PN-EN 61242"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"E Przedłużacze zwijane do zastosowań domowych i podobnych Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania PN-EN 61242 E Przedluzacze zwijane do zastosowan domowych i podobnych Cechy i wlasciwosci dla potrzeb oceny bezpieczenstwa uzytkowania PN-EN 61242","categories":["other"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"E Cable reels for household and similar purposes Characteristics and properties for the assessment of safety in use PN-EN 61242","methodology_zh":"用于使用安全性评定的特征与性能","search_zh":"用于使用安全性评定的特征与性能 PN-EN 61242"},{"_id":"6a5a55f09af9f73f38250e7b","lab_id":"69ad52a3de79e566650fb0c3","country":"PL","accr_number":"AB 012","accr_body":"PCA","test_object":"E Oprawy oświetleniowe","test_object_en":"E Luminaires","methodology":"Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania","methodology_en":"Characteristics and properties for the assessment of safety in use","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania","reference":"Normy","norm_bases":["Normy"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"E Oprawy oświetleniowe Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania Normy E Oprawy oswietleniowe Cechy i wlasciwosci dla potrzeb oceny bezpieczenstwa uzytkowania Normy","categories":["other"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"E Luminaires Characteristics and properties for the assessment of safety in use Normy","methodology_zh":"用于使用安全性评定的特征与性能","search_zh":"用于使用安全性评定的特征与性能 Normy"},{"_id":"6a5a55f09af9f73f38250e7c","lab_id":"69ad52a3de79e566650fb0c3","country":"PL","accr_number":"AB 012","accr_body":"PCA","test_object":"E Gniazda wtyczkowe i wtyczki","test_object_en":"E Socket-outlets and plugs","methodology":"Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania","methodology_en":"Characteristics and properties for the assessment of safety in use","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania","reference":"Normy","norm_bases":["Normy"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"E Gniazda wtyczkowe i wtyczki Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania Normy E Gniazda wtyczkowe i wtyczki Cechy i wlasciwosci dla potrzeb oceny bezpieczenstwa uzytkowania Normy","categories":["other"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"E Socket-outlets and plugs Characteristics and properties for the assessment of safety in use Normy","methodology_zh":"用于使用安全性评定的特征与性能","search_zh":"用于使用安全性评定的特征与性能 Normy"},{"_id":"6a5a55f09af9f73f38250e7d","lab_id":"69ad52a3de79e566650fb0c3","country":"PL","accr_number":"AB 012","accr_body":"PCA","test_object":"E Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne","test_object_en":"E Electrical, telecommunications and electronic products and equipment","methodology":"Badania środowiskowe","methodology_en":"Environmental testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania środowiskowe","reference":"Normy","norm_bases":["Normy"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"E Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Badania środowiskowe Normy E Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Badania srodowiskowe Normy","categories":["environment","electronics"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"E Electrical, telecommunications and electronic products and equipment Environmental testing Normy","search_zh":"E 电气、电信与电子产品及装备 Normy","test_object_zh":"E 电气、电信与电子产品及装备"},{"_id":"6a5a55f09af9f73f38250e7e","lab_id":"69ad52a3de79e566650fb0c3","country":"PL","accr_number":"AB 012","accr_body":"PCA","test_object":"E Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne","test_object_en":"E Electrical, telecommunications and electronic products and equipment","methodology":"Ochrona przed porażeniem prądem elektrycznym. Metody pomiaru: prądu dotykowego prądu w przewodzie ochronnym","methodology_en":"Protection against electric shock. Measurement methods: touch current protective conductor current","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ochrona przed porażeniem prądem elektrycznym. Metody pomiaru: prądu dotykowego prądu w przewodzie ochronnym","reference":"PN-EN 60990","norm_bases":["PN-EN 60990"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"E Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Ochrona przed porażeniem prądem elektrycznym. Metody pomiaru: prądu dotykowego prądu w przewodzie ochronnym PN-EN 60990 E Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Ochrona przed porazeniem pradem elektrycznym. Metody pomiaru: pradu dotykowego pradu w przewodzie ochronnym PN-EN 60990","categories":["electronics"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"E Electrical, telecommunications and electronic products and equipment Protection against electric shock. Measurement methods: touch current protective conductor current PN-EN 60990","search_zh":"E 电气、电信与电子产品及装备 PN-EN 60990","test_object_zh":"E 电气、电信与电子产品及装备"},{"_id":"6a5a55f09af9f73f38250e7f","lab_id":"69ad52a3de79e566650fb0c3","country":"PL","accr_number":"AB 012","accr_body":"PCA","test_object":"E Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne","test_object_en":"E Electrical, telecommunications and electronic products and equipment","methodology":"Odstępy izolacyjne powietrzne, Odstępy izolacyjne powierzchniowe Odstępy izolacyjne stałe","methodology_en":"Clearances, Creepage distances, Distances through solid insulation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odstępy izolacyjne powietrzne, Odstępy izolacyjne powierzchniowe Odstępy izolacyjne stałe","reference":"PN-EN 60664-1 IEC 60664-1","norm_bases":["PN-EN 60664-1 IEC 60664-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"E Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Odstępy izolacyjne powietrzne, Odstępy izolacyjne powierzchniowe Odstępy izolacyjne stałe PN-EN 60664-1 IEC 60664-1 E Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Odstepy izolacyjne powietrzne, Odstepy izolacyjne powierzchniowe Odstepy izolacyjne stale PN-EN 60664-1 IEC 60664-1","categories":["construction","electronics"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"E Electrical, telecommunications and electronic products and equipment Clearances, Creepage distances, Distances through solid insulation PN-EN 60664-1 IEC 60664-1","search_zh":"E 电气、电信与电子产品及装备 PN-EN 60664-1 IEC 60664-1","test_object_zh":"E 电气、电信与电子产品及装备"},{"_id":"6a5a55f09af9f73f38250e80","lab_id":"69ad52a3de79e566650fb0c3","country":"PL","accr_number":"AB 012","accr_body":"PCA","test_object":"E Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne","test_object_en":"E Electrical, telecommunications and electronic products and equipment","methodology":"Badania materiałowe","methodology_en":"Materials testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania materiałowe","reference":"Normy","norm_bases":["Normy"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"E Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Badania materiałowe Normy E Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Badania materialowe Normy","categories":["materials","electronics"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"E Electrical, telecommunications and electronic products and equipment Materials testing Normy","search_zh":"E 电气、电信与电子产品及装备 Normy","test_object_zh":"E 电气、电信与电子产品及装备"},{"_id":"6a5a55f09af9f73f38250e81","lab_id":"69ad52a3de79e566650fb0c3","country":"PL","accr_number":"AB 012","accr_body":"PCA","test_object":"E Urządzenia elektryczne i elektroniczne","test_object_en":"E Electrical and electronic equipment","methodology":"Napięcia zaburzeń radioelektrycznych na przewodach zasilania sieciowego","methodology_en":"Radio disturbance voltage on mains power leads","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Napięcia zaburzeń radioelektrycznych na przewodach zasilania sieciowego","reference":"Normy","norm_bases":["Normy"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"E Urządzenia elektryczne i elektroniczne Napięcia zaburzeń radioelektrycznych na przewodach zasilania sieciowego Normy E Urzadzenia elektryczne i elektroniczne Napiecia zaburzen radioelektrycznych na przewodach zasilania sieciowego Normy","categories":["electronics"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"E Electrical and electronic equipment Radio disturbance voltage on mains power leads Normy","search_zh":"E 电气与电子设备 Normy","test_object_zh":"E 电气与电子设备"},{"_id":"6a5a55f09af9f73f38250e82","lab_id":"69ad52a3de79e566650fb0c3","country":"PL","accr_number":"AB 012","accr_body":"PCA","test_object":"E Urządzenia elektryczne i elektroniczne","test_object_en":"E Electrical and electronic equipment","methodology":"Moc zaburzeń radioelektrycznych","methodology_en":"Radio disturbance power","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moc zaburzeń radioelektrycznych","reference":"Normy","norm_bases":["Normy"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"E Urządzenia elektryczne i elektroniczne Moc zaburzeń radioelektrycznych Normy E Urzadzenia elektryczne i elektroniczne Moc zaburzen radioelektrycznych Normy","categories":["electronics"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"E Electrical and electronic equipment Radio disturbance power Normy","search_zh":"E 电气与电子设备 Normy","test_object_zh":"E 电气与电子设备"},{"_id":"6a5a55f09af9f73f38250e83","lab_id":"69ad52a3de79e566650fb0c3","country":"PL","accr_number":"AB 012","accr_body":"PCA","test_object":"E Urządzenia elektryczne i elektroniczne","test_object_en":"E Electrical and electronic equipment","methodology":"Odporność na wyładowania elektrostatyczne (ESD) Zakres: ± (2; 4; 6; 8) kV wył. kontaktowe; ± (2; 4; 8; 15) kV wył. przez powietrze","methodology_en":"Immunity to electrostatic discharge (ESD) Range: ± (2; 4; 6; 8) kV contact discharges; ± (2; 4; 8; 15) kV air discharges","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na wyładowania elektrostatyczne (ESD) Zakres: ± (2; 4; 6; 8) kV wył. kontaktowe; ± (2; 4; 8; 15) kV wył. przez powietrze","reference":"Normy","norm_bases":["Normy"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"E Urządzenia elektryczne i elektroniczne Odporność na wyładowania elektrostatyczne (ESD) Zakres: ± (2; 4; 6; 8) kV wył. kontaktowe; ± (2; 4; 8; 15) kV wył. przez powietrze Normy E Urzadzenia elektryczne i elektroniczne Odpornosc na wyladowania elektrostatyczne (ESD) Zakres: ± (2; 4; 6; 8) kV wyl. kontaktowe; ± (2; 4; 8; 15) kV wyl. przez powietrze Normy","categories":["environment","electronics"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"E Electrical and electronic equipment Immunity to electrostatic discharge (ESD) Range: ± (2; 4; 6; 8) kV contact discharges; ± (2; 4; 8; 15) kV air discharges Normy","search_zh":"E 电气与电子设备 Normy","test_object_zh":"E 电气与电子设备"},{"_id":"6a5a55f09af9f73f38250e84","lab_id":"69ad52a3de79e566650fb0c3","country":"PL","accr_number":"AB 012","accr_body":"PCA","test_object":"Kasy i drukarki rejestrujące","test_object_en":"Cash registers and fiscal printers","methodology":"Zdolność do pracy z zasilania akumulatorowego po próbie 48- godzinnej","methodology_en":"Ability to operate from battery power after a 48- hour test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność do pracy z zasilania akumulatorowego po próbie 48- godzinnej","reference":"enie Ministra Rozwoju | enie Ministra Rozwoju i Technologii z dnia 2 marca 2023 r. zmieniające rozporządzenie w sprawie wymagań technicznych dla kas rejestrujących (Dz. U. z 2023 r. poz. 491)","norm_bases":["enie Ministra Rozwoju","enie Ministra Rozwoju i Technologii z dnia 2 marca 2023 r. zmieniające rozporządzenie w sprawie wymagań technicznych dla kas rejestrujących (Dz. U. z 2023 r. poz. 491)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kasy i drukarki rejestrujące Zdolność do pracy z zasilania akumulatorowego po próbie 48- godzinnej enie Ministra Rozwoju | enie Ministra Rozwoju i Technologii z dnia 2 marca 2023 r. zmieniające rozporządzenie w sprawie wymagań technicznych dla kas rejestrujących (Dz. U. z 2023 r. poz. 491) Kasy i drukarki rejestrujace Zdolnosc do pracy z zasilania akumulatorowego po probie 48- godzinnej enie Ministra Rozwoju | enie Ministra Rozwoju i Technologii z dnia 2 marca 2023 r. zmieniajace rozporzadzenie w sprawie wymagan technicznych dla kas rejestrujacych (Dz. U. z 2023 r. poz. 491)","categories":["other"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Cash registers and fiscal printers Ability to operate from battery power after a 48- hour test enie Ministra Rozwoju | enie Ministra Rozwoju i Technologii z dnia 2 marca 2023 r. zmieniające rozporządzenie w sprawie wymagań technicznych dla kas rejestrujących (Dz. U. z 2023 r. poz. 491)"},{"_id":"6a5a55f09af9f73f38250e85","lab_id":"69ad52a3de79e566650fb0c3","country":"PL","accr_number":"AB 012","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne o prądzie zasilającym ≤ 16 A","test_object_en":"Electrical and electronic equipment with input current ≤ 16 A","methodology":"Odporność na serie szybkich elektrycznych stanów przejściowych","methodology_en":"Immunity to electrical fast transients/bursts","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na serie szybkich elektrycznych stanów przejściowych","reference":"PN-EN 61000-4-4:2013-05","norm_bases":["PN-EN 61000-4-4:2013-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne o prądzie zasilającym ≤ 16 A Odporność na serie szybkich elektrycznych stanów przejściowych PN-EN 61000-4-4:2013-05 Urzadzenia elektryczne i elektroniczne o pradzie zasilajacym ≤ 16 A Odpornosc na serie szybkich elektrycznych stanow przejsciowych PN-EN 61000-4-4:2013-05","categories":["electronics"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical and electronic equipment with input current ≤ 16 A Immunity to electrical fast transients/bursts PN-EN 61000-4-4:2013-05","methodology_zh":"电快速瞬变脉冲群抗扰度","search_zh":"输入电流 ≤ 16 A 的电气与电子设备 电快速瞬变脉冲群抗扰度 PN-EN 61000-4-4:2013-05","test_object_zh":"输入电流 ≤ 16 A 的电气与电子设备"},{"_id":"6a5a55f09af9f73f38250e86","lab_id":"69ad52a3de79e566650fb0c3","country":"PL","accr_number":"AB 012","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne o prądzie zasilającym ≤ 16 A","test_object_en":"Electrical and electronic equipment with input current ≤ 16 A","methodology":"Odporność na udary Port 230 VAC","methodology_en":"Immunity to surges Port 230 VAC","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na udary Port 230 VAC","reference":"PN-EN 61000-4--5:2014-10+A1:2018- 01","norm_bases":["PN-EN 61000-4--5:2014-10+A1:2018- 01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne o prądzie zasilającym ≤ 16 A Odporność na udary Port 230 VAC PN-EN 61000-4--5:2014-10+A1:2018- 01 Urzadzenia elektryczne i elektroniczne o pradzie zasilajacym ≤ 16 A Odpornosc na udary Port 230 VAC PN-EN 61000-4--5:2014-10+A1:2018- 01","categories":["electronics"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical and electronic equipment with input current ≤ 16 A Immunity to surges Port 230 VAC PN-EN 61000-4--5:2014-10+A1:2018- 01","search_zh":"输入电流 ≤ 16 A 的电气与电子设备 PN-EN 61000-4--5:2014-10+A1:2018- 01","test_object_zh":"输入电流 ≤ 16 A 的电气与电子设备"},{"_id":"6a5a55f09af9f73f38250e87","lab_id":"69ad52a3de79e566650fb0c3","country":"PL","accr_number":"AB 012","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne o prądzie zasilającym ≤ 16 A","test_object_en":"Electrical and electronic equipment with input current ≤ 16 A","methodology":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia","methodology_en":"Immunity to voltage dips, short interruptions and voltage variations","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia","reference":"PN-EN IEC 61000-4-11:2020- 11+AC:2020-12+AC:2023:01","norm_bases":["PN-EN IEC 61000-4-11:2020- 11+AC:2020-12+AC:2023:01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne o prądzie zasilającym ≤ 16 A Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia PN-EN IEC 61000-4-11:2020- 11+AC:2020-12+AC:2023:01 Urzadzenia elektryczne i elektroniczne o pradzie zasilajacym ≤ 16 A Odpornosc na zapady napiecia, krotkie przerwy i zmiany napiecia PN-EN IEC 61000-4-11:2020- 11+AC:2020-12+AC:2023:01","categories":["electronics"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical and electronic equipment with input current ≤ 16 A Immunity to voltage dips, short interruptions and voltage variations PN-EN IEC 61000-4-11:2020- 11+AC:2020-12+AC:2023:01","methodology_zh":"电压暂降、短时中断与电压变化抗扰度","search_zh":"输入电流 ≤ 16 A 的电气与电子设备 电压暂降、短时中断与电压变化抗扰度 PN-EN IEC 61000-4-11:2020- 11+AC:2020-12+AC:2023:01","test_object_zh":"输入电流 ≤ 16 A 的电气与电子设备"}],"has_pdf":true}