{"lab":{"_id":"69ad52a3de79e566650fb0b9","accr_number":"AB 005","country":"PL","accr_body":"PCA","address":"PAŃSTWOWY INSTYTUT BADAWCZY, ZESPÓŁ LABORATORIÓW BADAWCZYCH I WZORCUJĄCYCH GIG-PIB, Pl. Gwarków 1, 40-166 Katowice, CENTRAL MINING INSTITUTE –, NATIONAL RESEARCH INSTITUTE","categories":["petro","environment","materials","water","construction","food"],"city":"Katowice","imported_at":"2026-03-08T10:42:43.265Z","methods_count":572,"name":"GŁÓWNY INSTYTUT GÓRNICTWA –","parse_status":"parsed","parse_version":3,"pdf_files":["AB_005.pdf"],"scope_summary":"","search_text":"główny instytut górnictwa – państwowy instytut badawczy, zespół laboratoriów badawczych i wzorcujących gig-pib, pl. gwarków 1, 40-166 katowice, central mining institute –, national research institute water other materials environment petro food construction automotive metrology pharma electronics microbiology","status":"active","updated_at":"2026-03-08T14:50:00.819Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:00.819Z","parse_date":"2026-07-17T16:18:55.545Z","parse_source":"m5-mistral-qa","email_confidence":"high","email_mx":true,"email_source":"https://bip.gig.eu/artykuly/dane-kontaktowe","fields_of_testing":[{"codes":"A/5; A/13","pl":"Badania akustyczne i drgań – obiekty budowlane (ekrany akustyczne, pomieszczenia w budynkach, budynki i budowle), maszyny i urządzenia","en":"Acoustic and vibration tests – building items (acoustic screens, rooms in buildings, buildings), machinery and devices"},{"codes":"C/4; C/5; C/8; C/9, C/10; C/12; C/17; C/21; C/32; C/36","pl":"Badania chemiczne – wyroby chemiczne, materiały budowlane, wyroby i materiały konstrukcyjne - w tym metale i kompozyty, powietrze, paliwa stałe, szkło i ceramika, wyroby z tworzyw sztucznych i gumy, wyroby inne, gleby, odpady, gazy","en":"Chemical tests – chemical products, building materials, construction products and materials - including metals and composite materials, air, solid fuels, glass and ceramics, plastic and rubber products, other products, soil, waste, gases"},{"codes":"C/10/P; C/28/P; C/29/P; C/30/P; C/31/P; C/32/P","pl":"Badania chemiczne i pobieranie próbek paliw stałych, wody, wody do spożycia przez ludzi, ścieków, gleb, gruntów, odpadów","en":"Chemical tests and sampling of solid fuels, water, drinking water, sewage, soil, ground, waste"},{"codes":"E/5; E/6; E/8; E/13; E/17; E/19; E/21; E/23, E/53; E/54","pl":"Badania elektryczne i elektroniczne – wyroby budowlane, materiały budowlane, obiekty budowlane, wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne, wyroby i materiały konstrukcyjne - w tym metale i kompozyty, maszyny i urządzenia, wyroby inne, środki ochrony osobistej, wyroby z tworzyw sztucznych i gumy, tekstylia i skóra, tkaniny, przędza, odzież oraz wyroby finalne","en":"Electric and electronic tests – building products, building materials, building items, electrical, telecommunication and electronic products and equipment, construction products and materials - including metals and composite materials, machinery and devices, other products, personal protection equipment, plastic and rubber products, textiles and leather, fabrics, yarn, clothes and final products"}],"issue":{"no":"29","date":"18.12.2025"},"map_coord":[50.259899,19.021585],"map_geo":"nominatim-city","has_en":true,"category_counts":{"petro":153,"other":130,"environment":125,"materials":114,"water":107,"construction":46,"food":5,"metrology":1,"microbiology":1},"category_scores":{"petro":34.32,"other":24.78,"environment":22.91,"materials":19.06,"water":16.79,"construction":3.1,"food":0.04,"metrology":0,"microbiology":0},"has_zh":true},"methods":[{"_id":"6a5a55ef9af9f73f38250a9c","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi Ścieki Water Drinking water Sewage","test_object_en":"Water Water intended for human consumption Wastewater","methodology":"Stężenie aktywności radionuklidu: 226Ra Zakres: (0,004 – 1000) Bq/dm3 (kBq/m3) Metoda spektrometrii ciekłoscyntylacyjnej (LSC) Activity concentration of radionuclide: 226Ra Range: (0,004 – 1000) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC)","methodology_en":"Activity concentration of radionuclide: 226Ra Range: (0,004 – 1000) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidu: 226Ra Zakres: (0,004 – 1000) Bq/dm3 (kBq/m3) Metoda spektrometrii ciekłoscyntylacyjnej (LSC) Activity concentration of radionuclide: 226Ra Range: (0,004 – 1000) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC)","reference":"Procedura SCR/ZLGIG/1-002 edycja 7 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-002 7th edition of 25 August 2023","norm_bases":["Procedura SCR/ZLGIG/1-002 edycja 7 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-002 7th edition of 25 August 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Ścieki Water Drinking water Sewage Stężenie aktywności radionuklidu: 226Ra Zakres: (0,004 – 1000) Bq/dm3 (kBq/m3) Metoda spektrometrii ciekłoscyntylacyjnej (LSC) Activity concentration of radionuclide: 226Ra Range: (0,004 – 1000) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC) Procedura SCR/ZLGIG/1-002 edycja 7 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-002 7th edition of 25 August 2023 Woda Woda do spozycia przez ludzi Scieki Water Drinking water Sewage Stezenie aktywnosci radionuklidu: 226Ra Zakres: (0,004 – 1000) Bq/dm3 (kBq/m3) Metoda spektrometrii ciekloscyntylacyjnej (LSC) Activity concentration of radionuclide: 226Ra Range: (0,004 – 1000) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC) Procedura SCR/ZLGIG/1-002 edycja 7 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-002 7th edition of 25 August 2023","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Wastewater Activity concentration of radionuclide: 226Ra Range: (0,004 – 1000) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC) Procedura SCR/ZLGIG/1-002 edycja 7 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-002 7th edition of 25 August 2023","search_zh":"水 生活饮用水 废水 Water Drinking water Sewage Procedura SCR/ZLGIG/1-002 edycja 7 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-002 7th edition of 25 August 2023","test_object_zh":"水 生活饮用水 废水 Water Drinking water Sewage"},{"_id":"6a5a55ef9af9f73f38250a9d","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi Ścieki Water Drinking water Sewage","test_object_en":"Water Water intended for human consumption Wastewater","methodology":"Stężenie aktywności radionuklidu: 228Ra Zakres: (0,02 – 1000) Bq/dm3 (kBq/m3) Metoda spektrometrii ciekłoscyntylacyjnej (LSC) Activity concentration of radionuclide: 228Ra Range: (0,02 – 1000) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC)","methodology_en":"Activity concentration of radionuclide: 228Ra Range: (0,02 – 1000) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidu: 228Ra Zakres: (0,02 – 1000) Bq/dm3 (kBq/m3) Metoda spektrometrii ciekłoscyntylacyjnej (LSC) Activity concentration of radionuclide: 228Ra Range: (0,02 – 1000) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC)","reference":"Procedura SCR/ZLGIG/1-002 edycja 7 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-002 7th edition of 25 August 2023","norm_bases":["Procedura SCR/ZLGIG/1-002 edycja 7 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-002 7th edition of 25 August 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Ścieki Water Drinking water Sewage Stężenie aktywności radionuklidu: 228Ra Zakres: (0,02 – 1000) Bq/dm3 (kBq/m3) Metoda spektrometrii ciekłoscyntylacyjnej (LSC) Activity concentration of radionuclide: 228Ra Range: (0,02 – 1000) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC) Procedura SCR/ZLGIG/1-002 edycja 7 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-002 7th edition of 25 August 2023 Woda Woda do spozycia przez ludzi Scieki Water Drinking water Sewage Stezenie aktywnosci radionuklidu: 228Ra Zakres: (0,02 – 1000) Bq/dm3 (kBq/m3) Metoda spektrometrii ciekloscyntylacyjnej (LSC) Activity concentration of radionuclide: 228Ra Range: (0,02 – 1000) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC) Procedura SCR/ZLGIG/1-002 edycja 7 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-002 7th edition of 25 August 2023","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Wastewater Activity concentration of radionuclide: 228Ra Range: (0,02 – 1000) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC) Procedura SCR/ZLGIG/1-002 edycja 7 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-002 7th edition of 25 August 2023","search_zh":"水 生活饮用水 废水 Water Drinking water Sewage Procedura SCR/ZLGIG/1-002 edycja 7 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-002 7th edition of 25 August 2023","test_object_zh":"水 生活饮用水 废水 Water Drinking water Sewage"},{"_id":"6a5a55ef9af9f73f38250a9e","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi Ścieki Water Drinking water Sewage","test_object_en":"Water Water intended for human consumption Wastewater","methodology":"Stężenie aktywności radionuklidu: 90Sr Zakres: (0,01 – 1000) Bq/dm3 (kBq/m3) Metoda spektrometrii ciekłoscyntylacyjnej (LSC) Activity concentration of radionuclide: 90Sr Range: (0,01 – 1000) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC)","methodology_en":"Activity concentration of radionuclide: 90Sr Range: (0,01 – 1000) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidu: 90Sr Zakres: (0,01 – 1000) Bq/dm3 (kBq/m3) Metoda spektrometrii ciekłoscyntylacyjnej (LSC) Activity concentration of radionuclide: 90Sr Range: (0,01 – 1000) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC)","reference":"Procedura SCR/ZLGIG/1-020 edycja 5 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-020 5th edition of 25 August 2023","norm_bases":["Procedura SCR/ZLGIG/1-020 edycja 5 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-020 5th edition of 25 August 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Ścieki Water Drinking water Sewage Stężenie aktywności radionuklidu: 90Sr Zakres: (0,01 – 1000) Bq/dm3 (kBq/m3) Metoda spektrometrii ciekłoscyntylacyjnej (LSC) Activity concentration of radionuclide: 90Sr Range: (0,01 – 1000) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC) Procedura SCR/ZLGIG/1-020 edycja 5 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-020 5th edition of 25 August 2023 Woda Woda do spozycia przez ludzi Scieki Water Drinking water Sewage Stezenie aktywnosci radionuklidu: 90Sr Zakres: (0,01 – 1000) Bq/dm3 (kBq/m3) Metoda spektrometrii ciekloscyntylacyjnej (LSC) Activity concentration of radionuclide: 90Sr Range: (0,01 – 1000) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC) Procedura SCR/ZLGIG/1-020 edycja 5 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-020 5th edition of 25 August 2023","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Wastewater Activity concentration of radionuclide: 90Sr Range: (0,01 – 1000) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC) Procedura SCR/ZLGIG/1-020 edycja 5 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-020 5th edition of 25 August 2023","search_zh":"水 生活饮用水 废水 Water Drinking water Sewage Procedura SCR/ZLGIG/1-020 edycja 5 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-020 5th edition of 25 August 2023","test_object_zh":"水 生活饮用水 废水 Water Drinking water Sewage"},{"_id":"6a5a55ef9af9f73f38250a9f","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi Ścieki Water Drinking water Sewage","test_object_en":"Water Water intended for human consumption Wastewater","methodology":"Stężenie aktywności radionuklidu: 3H Zakres: (5 – 1000) Bq/dm3 (kBq/m3) Metoda spektrometrii ciekłoscyntylacyjnej (LSC) Activity concentration of radionuclide: 3H Range: (5 – 1000) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC)","methodology_en":"Activity concentration of radionuclide: 3H Range: (5 – 1000) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidu: 3H Zakres: (5 – 1000) Bq/dm3 (kBq/m3) Metoda spektrometrii ciekłoscyntylacyjnej (LSC) Activity concentration of radionuclide: 3H Range: (5 – 1000) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC)","reference":"Procedura SCR/ZLGIG/1-017 edycja 4 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-017 4th edition of 25.08.2023","norm_bases":["Procedura SCR/ZLGIG/1-017 edycja 4 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-017 4th edition of 25.08.2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Ścieki Water Drinking water Sewage Stężenie aktywności radionuklidu: 3H Zakres: (5 – 1000) Bq/dm3 (kBq/m3) Metoda spektrometrii ciekłoscyntylacyjnej (LSC) Activity concentration of radionuclide: 3H Range: (5 – 1000) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC) Procedura SCR/ZLGIG/1-017 edycja 4 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-017 4th edition of 25.08.2023 Woda Woda do spozycia przez ludzi Scieki Water Drinking water Sewage Stezenie aktywnosci radionuklidu: 3H Zakres: (5 – 1000) Bq/dm3 (kBq/m3) Metoda spektrometrii ciekloscyntylacyjnej (LSC) Activity concentration of radionuclide: 3H Range: (5 – 1000) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC) Procedura SCR/ZLGIG/1-017 edycja 4 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-017 4th edition of 25.08.2023","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Wastewater Activity concentration of radionuclide: 3H Range: (5 – 1000) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC) Procedura SCR/ZLGIG/1-017 edycja 4 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-017 4th edition of 25.08.2023","search_zh":"水 生活饮用水 废水 Water Drinking water Sewage Procedura SCR/ZLGIG/1-017 edycja 4 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-017 4th edition of 25.08.2023","test_object_zh":"水 生活饮用水 废水 Water Drinking water Sewage"},{"_id":"6a5a55ef9af9f73f38250aa0","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi Ścieki Water Drinking water Sewage","test_object_en":"Water Water intended for human consumption Wastewater","methodology":"Stężenie aktywności radionuklidu: 222Rn Zakres: (2 – 4000) Bq/dm3 (kBq/m3) Metoda spektrometrii ciekłoscyntylacyjnej (LSC) Activity concentration of radionuclide: 222Rn Range: (2 – 4000) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC)","methodology_en":"Activity concentration of radionuclide: 222Rn Range: (2 – 4000) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidu: 222Rn Zakres: (2 – 4000) Bq/dm3 (kBq/m3) Metoda spektrometrii ciekłoscyntylacyjnej (LSC) Activity concentration of radionuclide: 222Rn Range: (2 – 4000) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC)","reference":"Procedura SCR/ZLGIG/1-022 edycja 3 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-022 3rd edition of 25 August 2023","norm_bases":["Procedura SCR/ZLGIG/1-022 edycja 3 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-022 3rd edition of 25 August 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Ścieki Water Drinking water Sewage Stężenie aktywności radionuklidu: 222Rn Zakres: (2 – 4000) Bq/dm3 (kBq/m3) Metoda spektrometrii ciekłoscyntylacyjnej (LSC) Activity concentration of radionuclide: 222Rn Range: (2 – 4000) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC) Procedura SCR/ZLGIG/1-022 edycja 3 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-022 3rd edition of 25 August 2023 Woda Woda do spozycia przez ludzi Scieki Water Drinking water Sewage Stezenie aktywnosci radionuklidu: 222Rn Zakres: (2 – 4000) Bq/dm3 (kBq/m3) Metoda spektrometrii ciekloscyntylacyjnej (LSC) Activity concentration of radionuclide: 222Rn Range: (2 – 4000) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC) Procedura SCR/ZLGIG/1-022 edycja 3 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-022 3rd edition of 25 August 2023","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Wastewater Activity concentration of radionuclide: 222Rn Range: (2 – 4000) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC) Procedura SCR/ZLGIG/1-022 edycja 3 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-022 3rd edition of 25 August 2023","search_zh":"水 生活饮用水 废水 Water Drinking water Sewage Procedura SCR/ZLGIG/1-022 edycja 3 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-022 3rd edition of 25 August 2023","test_object_zh":"水 生活饮用水 废水 Water Drinking water Sewage"},{"_id":"6a5a55ef9af9f73f38250aa1","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi Ścieki Water Drinking water Sewage","test_object_en":"Water Water intended for human consumption Wastewater","methodology":"Stężenie aktywności radionuklidu: 238U, 235U, 234U Zakres: 0,4 mBq/L – 3 GBq/L Metoda spektrometrii alfa Activity concentration of radionuclide: 238U, 235U, 234U Range: 0,4 mBq/L – 3 GBq/L Alpha spectrometry","methodology_en":"Activity concentration of radionuclide: 238U, 235U, 234U Range: 0,4 mBq/L – 3 GBq/L Alpha spectrometry","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidu: 238U, 235U, 234U Zakres: 0,4 mBq/L – 3 GBq/L Metoda spektrometrii alfa Activity concentration of radionuclide: 238U, 235U, 234U Range: 0,4 mBq/L – 3 GBq/L Alpha spectrometry","reference":"Procedura SCR/ZLGIG/1-023 edycja 1 z dnia 24.02.2025 r. Procedure SCR/ZLGIG/1-023 1st edition of 24 February 2025","norm_bases":["Procedura SCR/ZLGIG/1-023 edycja 1 z dnia 24.02.2025 r. Procedure SCR/ZLGIG/1-023 1st edition of 24 February 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Ścieki Water Drinking water Sewage Stężenie aktywności radionuklidu: 238U, 235U, 234U Zakres: 0,4 mBq/L – 3 GBq/L Metoda spektrometrii alfa Activity concentration of radionuclide: 238U, 235U, 234U Range: 0,4 mBq/L – 3 GBq/L Alpha spectrometry Procedura SCR/ZLGIG/1-023 edycja 1 z dnia 24.02.2025 r. Procedure SCR/ZLGIG/1-023 1st edition of 24 February 2025 Woda Woda do spozycia przez ludzi Scieki Water Drinking water Sewage Stezenie aktywnosci radionuklidu: 238U, 235U, 234U Zakres: 0,4 mBq/L – 3 GBq/L Metoda spektrometrii alfa Activity concentration of radionuclide: 238U, 235U, 234U Range: 0,4 mBq/L – 3 GBq/L Alpha spectrometry Procedura SCR/ZLGIG/1-023 edycja 1 z dnia 24.02.2025 r. Procedure SCR/ZLGIG/1-023 1st edition of 24 February 2025","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Wastewater Activity concentration of radionuclide: 238U, 235U, 234U Range: 0,4 mBq/L – 3 GBq/L Alpha spectrometry Procedura SCR/ZLGIG/1-023 edycja 1 z dnia 24.02.2025 r. Procedure SCR/ZLGIG/1-023 1st edition of 24 February 2025","search_zh":"水 生活饮用水 废水 Water Drinking water Sewage Procedura SCR/ZLGIG/1-023 edycja 1 z dnia 24.02.2025 r. Procedure SCR/ZLGIG/1-023 1st edition of 24 February 2025","test_object_zh":"水 生活饮用水 废水 Water Drinking water Sewage"},{"_id":"6a5a55ef9af9f73f38250aa2","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi Ścieki Water Drinking water Sewage","test_object_en":"Water Water intended for human consumption Wastewater","methodology":"Oznaczanie całkowitej promieniotwórczości alfa Zakres: (0,04 – 50) Bq/dm3 (kBq/m3) Metoda spektrometrii ciekłoscyntylacyjnej (LSC) Total alpha activity Range: (0,04 – 50) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC)","methodology_en":"Total alpha activity Range: (0,04 – 50) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Oznaczanie całkowitej promieniotwórczości alfa Zakres: (0,04 – 50) Bq/dm3 (kBq/m3) Metoda spektrometrii ciekłoscyntylacyjnej (LSC) Total alpha activity Range: (0,04 – 50) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC)","reference":"Procedura SCR/ZLGIG/1-021 edycja 4 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-021 4th edition of 25 August 2023","norm_bases":["Procedura SCR/ZLGIG/1-021 edycja 4 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-021 4th edition of 25 August 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Ścieki Water Drinking water Sewage Oznaczanie całkowitej promieniotwórczości alfa Zakres: (0,04 – 50) Bq/dm3 (kBq/m3) Metoda spektrometrii ciekłoscyntylacyjnej (LSC) Total alpha activity Range: (0,04 – 50) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC) Procedura SCR/ZLGIG/1-021 edycja 4 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-021 4th edition of 25 August 2023 Woda Woda do spozycia przez ludzi Scieki Water Drinking water Sewage Oznaczanie calkowitej promieniotworczosci alfa Zakres: (0,04 – 50) Bq/dm3 (kBq/m3) Metoda spektrometrii ciekloscyntylacyjnej (LSC) Total alpha activity Range: (0,04 – 50) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC) Procedura SCR/ZLGIG/1-021 edycja 4 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-021 4th edition of 25 August 2023","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Wastewater Total alpha activity Range: (0,04 – 50) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC) Procedura SCR/ZLGIG/1-021 edycja 4 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-021 4th edition of 25 August 2023","search_zh":"水 生活饮用水 废水 Water Drinking water Sewage Procedura SCR/ZLGIG/1-021 edycja 4 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-021 4th edition of 25 August 2023","test_object_zh":"水 生活饮用水 废水 Water Drinking water Sewage"},{"_id":"6a5a55ef9af9f73f38250aa3","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi Ścieki Water Drinking water Sewage","test_object_en":"Water Water intended for human consumption Wastewater","methodology":"Oznaczanie całkowitej promieniotwórczości beta Zakres: (0,1 – 50) Bq/dm3 (kBq/m3) Metoda spektrometrii ciekłoscyntylacyjnej (LSC) Total beta activity Range: (0,1 – 50) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC)","methodology_en":"Total beta activity Range: (0,1 – 50) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Oznaczanie całkowitej promieniotwórczości beta Zakres: (0,1 – 50) Bq/dm3 (kBq/m3) Metoda spektrometrii ciekłoscyntylacyjnej (LSC) Total beta activity Range: (0,1 – 50) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC)","reference":"Procedura SCR/ZLGIG/1-021 edycja 4 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-021 4th edition of 25.08.2023","norm_bases":["Procedura SCR/ZLGIG/1-021 edycja 4 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-021 4th edition of 25.08.2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Ścieki Water Drinking water Sewage Oznaczanie całkowitej promieniotwórczości beta Zakres: (0,1 – 50) Bq/dm3 (kBq/m3) Metoda spektrometrii ciekłoscyntylacyjnej (LSC) Total beta activity Range: (0,1 – 50) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC) Procedura SCR/ZLGIG/1-021 edycja 4 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-021 4th edition of 25.08.2023 Woda Woda do spozycia przez ludzi Scieki Water Drinking water Sewage Oznaczanie calkowitej promieniotworczosci beta Zakres: (0,1 – 50) Bq/dm3 (kBq/m3) Metoda spektrometrii ciekloscyntylacyjnej (LSC) Total beta activity Range: (0,1 – 50) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC) Procedura SCR/ZLGIG/1-021 edycja 4 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-021 4th edition of 25.08.2023","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Wastewater Total beta activity Range: (0,1 – 50) Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC) Procedura SCR/ZLGIG/1-021 edycja 4 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-021 4th edition of 25.08.2023","search_zh":"水 生活饮用水 废水 Water Drinking water Sewage Procedura SCR/ZLGIG/1-021 edycja 4 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-021 4th edition of 25.08.2023","test_object_zh":"水 生活饮用水 废水 Water Drinking water Sewage"},{"_id":"6a5a55ef9af9f73f38250aa4","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi Ścieki Water Drinking water Sewage","test_object_en":"Water Water intended for human consumption Wastewater","methodology":"Obliczanie dawki orientacyjnej wynikającej ze spożycia wody Calculation of Indicative Dose (ID) from water consumption","methodology_en":"Calculation of Indicative Dose (ID) from water consumption","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Obliczanie dawki orientacyjnej wynikającej ze spożycia wody Calculation of Indicative Dose (ID) from water consumption","reference":"Procedura SCR/ZLGIG/1-002 edycja 7 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-002 7th edition of 25.08.2023","norm_bases":["Procedura SCR/ZLGIG/1-002 edycja 7 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-002 7th edition of 25.08.2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Ścieki Water Drinking water Sewage Obliczanie dawki orientacyjnej wynikającej ze spożycia wody Calculation of Indicative Dose (ID) from water consumption Procedura SCR/ZLGIG/1-002 edycja 7 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-002 7th edition of 25.08.2023 Woda Woda do spozycia przez ludzi Scieki Water Drinking water Sewage Obliczanie dawki orientacyjnej wynikajacej ze spozycia wody Calculation of Indicative Dose (ID) from water consumption Procedura SCR/ZLGIG/1-002 edycja 7 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-002 7th edition of 25.08.2023","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Wastewater Calculation of Indicative Dose (ID) from water consumption Procedura SCR/ZLGIG/1-002 edycja 7 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-002 7th edition of 25.08.2023","search_zh":"水 生活饮用水 废水 Water Drinking water Sewage Procedura SCR/ZLGIG/1-002 edycja 7 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-002 7th edition of 25.08.2023","test_object_zh":"水 生活饮用水 废水 Water Drinking water Sewage"},{"_id":"6a5a55ef9af9f73f38250aa5","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi Ścieki Water Drinking water Sewage","test_object_en":"Water Water intended for human consumption Wastewater","methodology":"Stężenie radionuklidów gamma promieniotwórczych w zakresie energii: 40 – 2000 keV Zakres: 0,02 Bq/dm3 – 100 kBq/dm3 Metoda spektrometrii promieniowania gamma Activity concentration of gamma- emitting radionuclides in energy range 40 – 2000 keV Range: 0,02 Bq/dm3 – 100 kBq/dm3 Gamma-ray spectrometry","methodology_en":"Activity concentration of gamma- emitting radionuclides in energy range 40 – 2000 keV Range: 0,02 Bq/dm3 – 100 kBq/dm3 Gamma-ray spectrometry","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie radionuklidów gamma promieniotwórczych w zakresie energii: 40 – 2000 keV Zakres: 0,02 Bq/dm3 – 100 kBq/dm3 Metoda spektrometrii promieniowania gamma Activity concentration of gamma- emitting radionuclides in energy range 40 – 2000 keV Range: 0,02 Bq/dm3 – 100 kBq/dm3 Gamma-ray spectrometry","reference":"Procedura SCR/ZLGIG/2-004 edycja 8 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/2-004 8th edition of 25 August 2023","norm_bases":["Procedura SCR/ZLGIG/2-004 edycja 8 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/2-004 8th edition of 25 August 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Ścieki Water Drinking water Sewage Stężenie radionuklidów gamma promieniotwórczych w zakresie energii: 40 – 2000 keV Zakres: 0,02 Bq/dm3 – 100 kBq/dm3 Metoda spektrometrii promieniowania gamma Activity concentration of gamma- emitting radionuclides in energy range 40 – 2000 keV Range: 0,02 Bq/dm3 – 100 kBq/dm3 Gamma-ray spectrometry Procedura SCR/ZLGIG/2-004 edycja 8 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/2-004 8th edition of 25 August 2023 Woda Woda do spozycia przez ludzi Scieki Water Drinking water Sewage Stezenie radionuklidow gamma promieniotworczych w zakresie energii: 40 – 2000 keV Zakres: 0,02 Bq/dm3 – 100 kBq/dm3 Metoda spektrometrii promieniowania gamma Activity concentration of gamma- emitting radionuclides in energy range 40 – 2000 keV Range: 0,02 Bq/dm3 – 100 kBq/dm3 Gamma-ray spectrometry Procedura SCR/ZLGIG/2-004 edycja 8 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/2-004 8th edition of 25 August 2023","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Wastewater Activity concentration of gamma- emitting radionuclides in energy range 40 – 2000 keV Range: 0,02 Bq/dm3 – 100 kBq/dm3 Gamma-ray spectrometry Procedura SCR/ZLGIG/2-004 edycja 8 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/2-004 8th edition of 25 August 2023","search_zh":"水 生活饮用水 废水 Water Drinking water Sewage Procedura SCR/ZLGIG/2-004 edycja 8 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/2-004 8th edition of 25 August 2023","test_object_zh":"水 生活饮用水 废水 Water Drinking water Sewage"},{"_id":"6a5a55ef9af9f73f38250aa6","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi Ścieki Water Drinking water Sewage","test_object_en":"Water Water intended for human consumption Wastewater","methodology":"Obliczanie skutecznej dawki obciążającej dla jednostkowego wniknięcia badanego materiału Calculation of committed effective dose from intake of radioactive material","methodology_en":"Calculation of committed effective dose for unit intake of the tested material Calculation of committed effective dose from intake of radioactive material","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Obliczanie skutecznej dawki obciążającej dla jednostkowego wniknięcia badanego materiału Calculation of committed effective dose from intake of radioactive material","reference":"Procedura SCR/ZLGIG/2-005 edycja 3 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/2-005 3rd edition of 25 August 2023","norm_bases":["Procedura SCR/ZLGIG/2-005 edycja 3 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/2-005 3rd edition of 25 August 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Ścieki Water Drinking water Sewage Obliczanie skutecznej dawki obciążającej dla jednostkowego wniknięcia badanego materiału Calculation of committed effective dose from intake of radioactive material Procedura SCR/ZLGIG/2-005 edycja 3 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/2-005 3rd edition of 25 August 2023 Woda Woda do spozycia przez ludzi Scieki Water Drinking water Sewage Obliczanie skutecznej dawki obciazajacej dla jednostkowego wnikniecia badanego materialu Calculation of committed effective dose from intake of radioactive material Procedura SCR/ZLGIG/2-005 edycja 3 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/2-005 3rd edition of 25 August 2023","categories":["water","materials"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Wastewater Calculation of committed effective dose for unit intake of the tested material Calculation of committed effective dose from intake of radioactive material Procedura SCR/ZLGIG/2-005 edycja 3 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/2-005 3rd edition of 25 August 2023","search_zh":"水 生活饮用水 废水 Water Drinking water Sewage Procedura SCR/ZLGIG/2-005 edycja 3 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/2-005 3rd edition of 25 August 2023","test_object_zh":"水 生活饮用水 废水 Water Drinking water Sewage"},{"_id":"6a5a55ef9af9f73f38250aa7","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Powietrze Obiekty budowlane Air Building items","test_object_en":"Air Building items","methodology":"Stężenie izotopu radonu 222Rn Zakres dla 1 miesiąca ekspozycji detektora: 31 – 11 111 Bq/m3 Metoda detektorów śladowych Activity concentration of radon 222Rn Range for 1 month exposition: 31 – 11 111 Bq/m3 Track detectors","methodology_en":"Activity concentration of radon 222Rn Range for 1 month exposition: 31 – 11 111 Bq/m3 Track detectors","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie izotopu radonu 222Rn Zakres dla 1 miesiąca ekspozycji detektora: 31 – 11 111 Bq/m3 Metoda detektorów śladowych Activity concentration of radon 222Rn Range for 1 month exposition: 31 – 11 111 Bq/m3 Track detectors","reference":"Procedura SCR/ZLGIG/2-011 edycja 4 z dnia 05.05.2025 Procedure SCR/ZLGIG/2-011 4th edition of 05 May 2025","norm_bases":["Procedura SCR/ZLGIG/2-011 edycja 4 z dnia 05.05.2025 Procedure SCR/ZLGIG/2-011 4th edition of 05 May 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powietrze Obiekty budowlane Air Building items Stężenie izotopu radonu 222Rn Zakres dla 1 miesiąca ekspozycji detektora: 31 – 11 111 Bq/m3 Metoda detektorów śladowych Activity concentration of radon 222Rn Range for 1 month exposition: 31 – 11 111 Bq/m3 Track detectors Procedura SCR/ZLGIG/2-011 edycja 4 z dnia 05.05.2025 Procedure SCR/ZLGIG/2-011 4th edition of 05 May 2025 Powietrze Obiekty budowlane Air Building items Stezenie izotopu radonu 222Rn Zakres dla 1 miesiaca ekspozycji detektora: 31 – 11 111 Bq/m3 Metoda detektorow sladowych Activity concentration of radon 222Rn Range for 1 month exposition: 31 – 11 111 Bq/m3 Track detectors Procedura SCR/ZLGIG/2-011 edycja 4 z dnia 05.05.2025 Procedure SCR/ZLGIG/2-011 4th edition of 05 May 2025","categories":["environment","construction"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Air Building items Activity concentration of radon 222Rn Range for 1 month exposition: 31 – 11 111 Bq/m3 Track detectors Procedura SCR/ZLGIG/2-011 edycja 4 z dnia 05.05.2025 Procedure SCR/ZLGIG/2-011 4th edition of 05 May 2025"},{"_id":"6a5a55ef9af9f73f38250aa8","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Powietrze Obiekty budowlane Air Building items","test_object_en":"Air Building items","methodology":"Stężenie izotopu radonu 222Rn Zakres dla dowolnego czasu ekspozycji detektora: 40 – 8000 kBq*h/m3 podzielony przez czas ekspozycji detektora wyrażony w godzinach Metoda detektorów śladowych Activity concentration of radon 222Rn Range for given time of exposition: 40 – 8000 kBq*h/m3 divided by exposition time expressed in hours Track detectors","methodology_en":"Activity concentration of radon 222Rn Range for given time of exposition: 40 – 8000 kBq*h/m3 divided by exposition time expressed in hours Track detectors","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie izotopu radonu 222Rn Zakres dla dowolnego czasu ekspozycji detektora: 40 – 8000 kBq*h/m3 podzielony przez czas ekspozycji detektora wyrażony w godzinach Metoda detektorów śladowych Activity concentration of radon 222Rn Range for given time of exposition: 40 – 8000 kBq*h/m3 divided by exposition time expressed in hours Track detectors","reference":"Procedura SCR/ZLGIG/2-011 edycja 4 z dnia 05.05.2025 Procedure SCR/ZLGIG/2-011 4th edition of 05 May 2025","norm_bases":["Procedura SCR/ZLGIG/2-011 edycja 4 z dnia 05.05.2025 Procedure SCR/ZLGIG/2-011 4th edition of 05 May 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powietrze Obiekty budowlane Air Building items Stężenie izotopu radonu 222Rn Zakres dla dowolnego czasu ekspozycji detektora: 40 – 8000 kBq*h/m3 podzielony przez czas ekspozycji detektora wyrażony w godzinach Metoda detektorów śladowych Activity concentration of radon 222Rn Range for given time of exposition: 40 – 8000 kBq*h/m3 divided by exposition time expressed in hours Track detectors Procedura SCR/ZLGIG/2-011 edycja 4 z dnia 05.05.2025 Procedure SCR/ZLGIG/2-011 4th edition of 05 May 2025 Powietrze Obiekty budowlane Air Building items Stezenie izotopu radonu 222Rn Zakres dla dowolnego czasu ekspozycji detektora: 40 – 8000 kBq*h/m3 podzielony przez czas ekspozycji detektora wyrazony w godzinach Metoda detektorow sladowych Activity concentration of radon 222Rn Range for given time of exposition: 40 – 8000 kBq*h/m3 divided by exposition time expressed in hours Track detectors Procedura SCR/ZLGIG/2-011 edycja 4 z dnia 05.05.2025 Procedure SCR/ZLGIG/2-011 4th edition of 05 May 2025","categories":["environment","construction"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Air Building items Activity concentration of radon 222Rn Range for given time of exposition: 40 – 8000 kBq*h/m3 divided by exposition time expressed in hours Track detectors Procedura SCR/ZLGIG/2-011 edycja 4 z dnia 05.05.2025 Procedure SCR/ZLGIG/2-011 4th edition of 05 May 2025"},{"_id":"6a5a55ef9af9f73f38250aa9","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Gleba, grunty, skały Osady Powietrze Paliwa Obiekty i materiały biologiczne przeznaczone do badań (ludzkie, zwierzęce, roślinne i inne naturalne) Żywność Produkty rolne Pasze dla zwierząt Wyroby, materiały budowlane Wyroby inne Filtr powietrza Soil, ground, rocks Sediments Air Fuels Biological items and materials for testing (human, animal, vegetable and other natural) Food Agricultural products Animal feedstuffs Building products, materials Other products Air filter Odpady O): kod / Waste O): code 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 02, 01 04 07*, 01 04 08, 01 04 11, 01 04 12, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*,10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 10 05 80, 10 09 99, 10 11 03, 10 11 99, 12 01 21, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07,17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 02 06, 19 09 02, 19 08 14, 19 09 04, 19 09 99, 19 12 09, 19 13 06","test_object_en":"Soil, ground, rocks Sediments Air Fuels Biological items and materials for testing (human, animal, vegetable and other natural) Food Agricultural products Animal feedstuffs Building products, materials Other products Air filter Waste O): code 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 02, 01 04 07*, 01 04 08, 01 04 11, 01 04 12, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*,10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 10 05 80, 10 09 99, 10 11 03, 10 11 99, 12 01 21, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07,17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 02 06, 19 09 02, 19 08 14, 19 09 04, 19 09 99, 19 12 09, 19 13 06","methodology":"Stężenie radionuklidów gamma promieniotwórczych w zakresie energii: Zakres energii mierzonego promieniowania gamma: 40 – 2000 keV Zakres oznaczania: 0,1 Bq/kg – 100 MBq/kg Metoda spektrometrii promieniowania gamma Activity concentration of gamma- emitting radionuclides in energy range 40 – 2000 keV Range: 0,1 Bq/kg – 100 MBq/kg Gamma-ray spectrometry","methodology_en":"Activity concentration of gamma- emitting radionuclides in the energy range: Energy range of the measured gamma radiation: 40 – 2000 keV Determination range: 0,1 Bq/kg – 100 MBq/kg Gamma-ray spectrometry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie radionuklidów gamma promieniotwórczych w zakresie energii: Zakres energii mierzonego promieniowania gamma: 40 – 2000 keV Zakres oznaczania: 0,1 Bq/kg – 100 MBq/kg Metoda spektrometrii promieniowania gamma Activity concentration of gamma- emitting radionuclides in energy range 40 – 2000 keV Range: 0,1 Bq/kg – 100 MBq/kg Gamma-ray spectrometry","reference":"Procedura SCR/ZLGIG/2-004 edycja 8 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/2-004 8th edition of 25 August 2023","norm_bases":["Procedura SCR/ZLGIG/2-004 edycja 8 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/2-004 8th edition of 25 August 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba, grunty, skały Osady Powietrze Paliwa Obiekty i materiały biologiczne przeznaczone do badań (ludzkie, zwierzęce, roślinne i inne naturalne) Żywność Produkty rolne Pasze dla zwierząt Wyroby, materiały budowlane Wyroby inne Filtr powietrza Soil, ground, rocks Sediments Air Fuels Biological items and materials for testing (human, animal, vegetable and other natural) Food Agricultural products Animal feedstuffs Building products, materials Other products Air filter Odpady O): kod / Waste O): code 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 02, 01 04 07*, 01 04 08, 01 04 11, 01 04 12, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*,10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 10 05 80, 10 09 99, 10 11 03, 10 11 99, 12 01 21, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07,17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 02 06, 19 09 02, 19 08 14, 19 09 04, 19 09 99, 19 12 09, 19 13 06 Stężenie radionuklidów gamma promieniotwórczych w zakresie energii: Zakres energii mierzonego promieniowania gamma: 40 – 2000 keV Zakres oznaczania: 0,1 Bq/kg – 100 MBq/kg Metoda spektrometrii promieniowania gamma Activity concentration of gamma- emitting radionuclides in energy range 40 – 2000 keV Range: 0,1 Bq/kg – 100 MBq/kg Gamma-ray spectrometry Procedura SCR/ZLGIG/2-004 edycja 8 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/2-004 8th edition of 25 August 2023 Gleba, grunty, skaly Osady Powietrze Paliwa Obiekty i materialy biologiczne przeznaczone do badan (ludzkie, zwierzece, roslinne i inne naturalne) Zywnosc Produkty rolne Pasze dla zwierzat Wyroby, materialy budowlane Wyroby inne Filtr powietrza Soil, ground, rocks Sediments Air Fuels Biological items and materials for testing (human, animal, vegetable and other natural) Food Agricultural products Animal feedstuffs Building products, materials Other products Air filter Odpady O): kod / Waste O): code 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 02, 01 04 07*, 01 04 08, 01 04 11, 01 04 12, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*,10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 10 05 80, 10 09 99, 10 11 03, 10 11 99, 12 01 21, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07,17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 02 06, 19 09 02, 19 08 14, 19 09 04, 19 09 99, 19 12 09, 19 13 06 Stezenie radionuklidow gamma promieniotworczych w zakresie energii: Zakres energii mierzonego promieniowania gamma: 40 – 2000 keV Zakres oznaczania: 0,1 Bq/kg – 100 MBq/kg Metoda spektrometrii promieniowania gamma Activity concentration of gamma- emitting radionuclides in energy range 40 – 2000 keV Range: 0,1 Bq/kg – 100 MBq/kg Gamma-ray spectrometry Procedura SCR/ZLGIG/2-004 edycja 8 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/2-004 8th edition of 25 August 2023","categories":["environment","food","materials","water","petro","construction"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil, ground, rocks Sediments Air Fuels Biological items and materials for testing (human, animal, vegetable and other natural) Food Agricultural products Animal feedstuffs Building products, materials Other products Air filter Waste O): code 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 02, 01 04 07*, 01 04 08, 01 04 11, 01 04 12, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*,10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 10 05 80, 10 09 99, 10 11 03, 10 11 99, 12 01 21, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07,17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 02 06, 19 09 02, 19 08 14, 19 09 04, 19 09 99, 19 12 09, 19 13 06 Activity concentration of gamma- emitting radionuclides in the energy range: Energy range of the measured gamma radiation: 40 – 2000 keV Determination range: 0,1 Bq/kg – 100 MBq/kg Gamma-ray spectrometry method Procedura SCR/ZLGIG/2-004 edycja 8 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/2-004 8th edition of 25 August 2023"},{"_id":"6a5a55ef9af9f73f38250aaa","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Gleba, grunty, skały Osady Nawozy Paliwa Obiekty i materiały biologiczne (ludzkie, zwierzęce, roślinne i inne naturalne) Żywność Produkty rolne Pasze dla zwierząt Wyroby inne Filtr powietrza Soil, ground, rocks Sediments Frtilizers Fuels Biological items and materials (human, animal, vegetable and other natural) Food Agricultural products Animal feedstuffs Other products Air filter Odpady O): kod / Waste O): code 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 02, 01 04 07*, 01 04 08, 01 04 11, 01 04 12, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 10 05 80, 10 09 99, 10 11 03, 10 11 99, 12 01 21, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 02 06, 19 09 02, 19 08 14, 19 09 04, 19 09 99, 19 12 09, 19 13 06","test_object_en":"Soil, ground, rocks Sediments Frtilizers Fuels Biological items and materials (human, animal, vegetable and other natural) Food Agricultural products Animal feedstuffs Other products Air filter Waste O): code 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 02, 01 04 07*, 01 04 08, 01 04 11, 01 04 12, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 10 05 80, 10 09 99, 10 11 03, 10 11 99, 12 01 21, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 02 06, 19 09 02, 19 08 14, 19 09 04, 19 09 99, 19 12 09, 19 13 06","methodology":"Stężenie aktywności radionuklidu: 238U, 235U, 234U Zakres: 0,02 Bq/kg – 3 GBq/kg Metoda spektrometrii alfa Activity concentration of radionuclide: 238U, 235U, 234U Range: 0,02 Bq/kg – 3 GBq/kg Alpha spectrometry","methodology_en":"Activity concentration of radionuclide: 238U, 235U, 234U Range: 0,02 Bq/kg – 3 GBq/kg Alpha spectrometry","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidu: 238U, 235U, 234U Zakres: 0,02 Bq/kg – 3 GBq/kg Metoda spektrometrii alfa Activity concentration of radionuclide: 238U, 235U, 234U Range: 0,02 Bq/kg – 3 GBq/kg Alpha spectrometry","reference":"Procedura SCR/ZLGIG/1-023 edycja 1 z dnia 24.02.2025 r. Procedure SCR/ZLGIG/1-023 1st edition of 24 February 2025","norm_bases":["Procedura SCR/ZLGIG/1-023 edycja 1 z dnia 24.02.2025 r. Procedure SCR/ZLGIG/1-023 1st edition of 24 February 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba, grunty, skały Osady Nawozy Paliwa Obiekty i materiały biologiczne (ludzkie, zwierzęce, roślinne i inne naturalne) Żywność Produkty rolne Pasze dla zwierząt Wyroby inne Filtr powietrza Soil, ground, rocks Sediments Frtilizers Fuels Biological items and materials (human, animal, vegetable and other natural) Food Agricultural products Animal feedstuffs Other products Air filter Odpady O): kod / Waste O): code 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 02, 01 04 07*, 01 04 08, 01 04 11, 01 04 12, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 10 05 80, 10 09 99, 10 11 03, 10 11 99, 12 01 21, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 02 06, 19 09 02, 19 08 14, 19 09 04, 19 09 99, 19 12 09, 19 13 06 Stężenie aktywności radionuklidu: 238U, 235U, 234U Zakres: 0,02 Bq/kg – 3 GBq/kg Metoda spektrometrii alfa Activity concentration of radionuclide: 238U, 235U, 234U Range: 0,02 Bq/kg – 3 GBq/kg Alpha spectrometry Procedura SCR/ZLGIG/1-023 edycja 1 z dnia 24.02.2025 r. Procedure SCR/ZLGIG/1-023 1st edition of 24 February 2025 Gleba, grunty, skaly Osady Nawozy Paliwa Obiekty i materialy biologiczne (ludzkie, zwierzece, roslinne i inne naturalne) Zywnosc Produkty rolne Pasze dla zwierzat Wyroby inne Filtr powietrza Soil, ground, rocks Sediments Frtilizers Fuels Biological items and materials (human, animal, vegetable and other natural) Food Agricultural products Animal feedstuffs Other products Air filter Odpady O): kod / Waste O): code 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 02, 01 04 07*, 01 04 08, 01 04 11, 01 04 12, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 10 05 80, 10 09 99, 10 11 03, 10 11 99, 12 01 21, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 02 06, 19 09 02, 19 08 14, 19 09 04, 19 09 99, 19 12 09, 19 13 06 Stezenie aktywnosci radionuklidu: 238U, 235U, 234U Zakres: 0,02 Bq/kg – 3 GBq/kg Metoda spektrometrii alfa Activity concentration of radionuclide: 238U, 235U, 234U Range: 0,02 Bq/kg – 3 GBq/kg Alpha spectrometry Procedura SCR/ZLGIG/1-023 edycja 1 z dnia 24.02.2025 r. Procedure SCR/ZLGIG/1-023 1st edition of 24 February 2025","categories":["food","environment","materials","water","petro"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil, ground, rocks Sediments Frtilizers Fuels Biological items and materials (human, animal, vegetable and other natural) Food Agricultural products Animal feedstuffs Other products Air filter Waste O): code 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 02, 01 04 07*, 01 04 08, 01 04 11, 01 04 12, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 10 05 80, 10 09 99, 10 11 03, 10 11 99, 12 01 21, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 02 06, 19 09 02, 19 08 14, 19 09 04, 19 09 99, 19 12 09, 19 13 06 Activity concentration of radionuclide: 238U, 235U, 234U Range: 0,02 Bq/kg – 3 GBq/kg Alpha spectrometry Procedura SCR/ZLGIG/1-023 edycja 1 z dnia 24.02.2025 r. Procedure SCR/ZLGIG/1-023 1st edition of 24 February 2025"},{"_id":"6a5a55ef9af9f73f38250aab","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Gleba, grunty, skały Osady Powietrze Paliwa Wyroby inne Filtr powietrza Soil, ground, rocks Sediments Air Fuels Other products Air filter Odpady O) :kod/ Waste O): code 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 02, 01 04 07*, 01 04 08, 01 04 11, 01 04 12, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 10 05 80, 10 09 99, 10 11 03, 10 11 99, 12 01 21, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 02 06, 19 09 02, 19 08 14, 19 09 04, 19 09 99, 19 12 09, 19 13 06","test_object_en":"Soil, ground, rocks Sediments Air Fuels Other products Air filter Waste O): code 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 02, 01 04 07*, 01 04 08, 01 04 11, 01 04 12, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 10 05 80, 10 09 99, 10 11 03, 10 11 99, 12 01 21, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 02 06, 19 09 02, 19 08 14, 19 09 04, 19 09 99, 19 12 09, 19 13 06","methodology":"Stężenie aktywności radionuklidu: 90Sr Zakres: 2 Bq/kg – 0,2 MBq/kg Metoda spektrometrii ciekłoscyntylacyjnej (LSC) Activity concentration of radionuclide: 90Sr Range: 2 Bq/kg – 0,2 MBq/kg Liquid Scintillation Counting (LSC)","methodology_en":"Activity concentration of radionuclide: 90Sr Range: 2 Bq/kg – 0,2 MBq/kg Liquid Scintillation Counting (LSC)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidu: 90Sr Zakres: 2 Bq/kg – 0,2 MBq/kg Metoda spektrometrii ciekłoscyntylacyjnej (LSC) Activity concentration of radionuclide: 90Sr Range: 2 Bq/kg – 0,2 MBq/kg Liquid Scintillation Counting (LSC)","reference":"Procedura SCR/ZLGIG/1-020 edycja 5 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-020 5th edition of 25 August 2023","norm_bases":["Procedura SCR/ZLGIG/1-020 edycja 5 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-020 5th edition of 25 August 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba, grunty, skały Osady Powietrze Paliwa Wyroby inne Filtr powietrza Soil, ground, rocks Sediments Air Fuels Other products Air filter Odpady O) :kod/ Waste O): code 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 02, 01 04 07*, 01 04 08, 01 04 11, 01 04 12, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 10 05 80, 10 09 99, 10 11 03, 10 11 99, 12 01 21, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 02 06, 19 09 02, 19 08 14, 19 09 04, 19 09 99, 19 12 09, 19 13 06 Stężenie aktywności radionuklidu: 90Sr Zakres: 2 Bq/kg – 0,2 MBq/kg Metoda spektrometrii ciekłoscyntylacyjnej (LSC) Activity concentration of radionuclide: 90Sr Range: 2 Bq/kg – 0,2 MBq/kg Liquid Scintillation Counting (LSC) Procedura SCR/ZLGIG/1-020 edycja 5 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-020 5th edition of 25 August 2023 Gleba, grunty, skaly Osady Powietrze Paliwa Wyroby inne Filtr powietrza Soil, ground, rocks Sediments Air Fuels Other products Air filter Odpady O) :kod/ Waste O): code 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 02, 01 04 07*, 01 04 08, 01 04 11, 01 04 12, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 10 05 80, 10 09 99, 10 11 03, 10 11 99, 12 01 21, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 02 06, 19 09 02, 19 08 14, 19 09 04, 19 09 99, 19 12 09, 19 13 06 Stezenie aktywnosci radionuklidu: 90Sr Zakres: 2 Bq/kg – 0,2 MBq/kg Metoda spektrometrii ciekloscyntylacyjnej (LSC) Activity concentration of radionuclide: 90Sr Range: 2 Bq/kg – 0,2 MBq/kg Liquid Scintillation Counting (LSC) Procedura SCR/ZLGIG/1-020 edycja 5 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-020 5th edition of 25 August 2023","categories":["environment","water","petro"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil, ground, rocks Sediments Air Fuels Other products Air filter Waste O): code 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 02, 01 04 07*, 01 04 08, 01 04 11, 01 04 12, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 10 05 80, 10 09 99, 10 11 03, 10 11 99, 12 01 21, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 02 06, 19 09 02, 19 08 14, 19 09 04, 19 09 99, 19 12 09, 19 13 06 Activity concentration of radionuclide: 90Sr Range: 2 Bq/kg – 0,2 MBq/kg Liquid Scintillation Counting (LSC) Procedura SCR/ZLGIG/1-020 edycja 5 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-020 5th edition of 25 August 2023"},{"_id":"6a5a55ef9af9f73f38250aac","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Obiekty i materiały biologiczne (ludzkie, zwierzęce, roślinne i inne naturalne) Żywność Produkty rolne Pasze dla zwierząt Biological items and materials (human, animal, vegetable and other natural) Food Agricultural products Animal feedstuffs","test_object_en":"Biological items and materials (human, animal, vegetable and other natural) Food Agricultural products Animal feedstuffs","methodology":"Stężenie aktywności radionuklidu: 90Sr Zakres: 0,06 – 1000 Bq/kg Metoda spektrometrii ciekłoscyntylacyjnej (LSC) Activity concentration of radionuclide: 90Sr Range: 0,06 – 1000 Bq/kg Liquid Scintillation Counting (LSC)","methodology_en":"Activity concentration of radionuclide: 90Sr Range: 0,06 – 1000 Bq/kg Liquid Scintillation Counting (LSC)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidu: 90Sr Zakres: 0,06 – 1000 Bq/kg Metoda spektrometrii ciekłoscyntylacyjnej (LSC) Activity concentration of radionuclide: 90Sr Range: 0,06 – 1000 Bq/kg Liquid Scintillation Counting (LSC)","reference":"Procedura SCR/ZLGIG/1-020 edycja 5 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-020 5th edition of 25 August 2023","norm_bases":["Procedura SCR/ZLGIG/1-020 edycja 5 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-020 5th edition of 25 August 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Obiekty i materiały biologiczne (ludzkie, zwierzęce, roślinne i inne naturalne) Żywność Produkty rolne Pasze dla zwierząt Biological items and materials (human, animal, vegetable and other natural) Food Agricultural products Animal feedstuffs Stężenie aktywności radionuklidu: 90Sr Zakres: 0,06 – 1000 Bq/kg Metoda spektrometrii ciekłoscyntylacyjnej (LSC) Activity concentration of radionuclide: 90Sr Range: 0,06 – 1000 Bq/kg Liquid Scintillation Counting (LSC) Procedura SCR/ZLGIG/1-020 edycja 5 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-020 5th edition of 25 August 2023 Obiekty i materialy biologiczne (ludzkie, zwierzece, roslinne i inne naturalne) Zywnosc Produkty rolne Pasze dla zwierzat Biological items and materials (human, animal, vegetable and other natural) Food Agricultural products Animal feedstuffs Stezenie aktywnosci radionuklidu: 90Sr Zakres: 0,06 – 1000 Bq/kg Metoda spektrometrii ciekloscyntylacyjnej (LSC) Activity concentration of radionuclide: 90Sr Range: 0,06 – 1000 Bq/kg Liquid Scintillation Counting (LSC) Procedura SCR/ZLGIG/1-020 edycja 5 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-020 5th edition of 25 August 2023","categories":["food","materials"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Biological items and materials (human, animal, vegetable and other natural) Food Agricultural products Animal feedstuffs Activity concentration of radionuclide: 90Sr Range: 0,06 – 1000 Bq/kg Liquid Scintillation Counting (LSC) Procedura SCR/ZLGIG/1-020 edycja 5 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/1-020 5th edition of 25 August 2023"},{"_id":"6a5a55ef9af9f73f38250aad","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Obiekty i materiały biologiczne (ludzkie, zwierzęce, roślinne i inne naturalne) Żywność Produkty rolne Pasze dla zwierząt Biological items and materials (human, animal, vegetable and other natural) Food Agricultural products Animal feedstuffs","test_object_en":"Biological items and materials (human, animal, vegetable and other natural) Food Agricultural products Animal feedstuffs","methodology":"Stężenie aktywności radionuklidu: 90Sr Zakres: 0,06 – 1000 Bq/dm3 (kBq/m3) Metoda spektrometrii ciekłoscyntylacyjnej (LSC) Activity concentration of radionuclide: 90Sr Range: 0,06 – 1000 Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC)","methodology_en":"Activity concentration of radionuclide: 90Sr Range: 0,06 – 1000 Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidu: 90Sr Zakres: 0,06 – 1000 Bq/dm3 (kBq/m3) Metoda spektrometrii ciekłoscyntylacyjnej (LSC) Activity concentration of radionuclide: 90Sr Range: 0,06 – 1000 Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Obiekty i materiały biologiczne (ludzkie, zwierzęce, roślinne i inne naturalne) Żywność Produkty rolne Pasze dla zwierząt Biological items and materials (human, animal, vegetable and other natural) Food Agricultural products Animal feedstuffs Stężenie aktywności radionuklidu: 90Sr Zakres: 0,06 – 1000 Bq/dm3 (kBq/m3) Metoda spektrometrii ciekłoscyntylacyjnej (LSC) Activity concentration of radionuclide: 90Sr Range: 0,06 – 1000 Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC) Obiekty i materialy biologiczne (ludzkie, zwierzece, roslinne i inne naturalne) Zywnosc Produkty rolne Pasze dla zwierzat Biological items and materials (human, animal, vegetable and other natural) Food Agricultural products Animal feedstuffs Stezenie aktywnosci radionuklidu: 90Sr Zakres: 0,06 – 1000 Bq/dm3 (kBq/m3) Metoda spektrometrii ciekloscyntylacyjnej (LSC) Activity concentration of radionuclide: 90Sr Range: 0,06 – 1000 Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC)","categories":["food","materials"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Biological items and materials (human, animal, vegetable and other natural) Food Agricultural products Animal feedstuffs Activity concentration of radionuclide: 90Sr Range: 0,06 – 1000 Bq/dm3 (kBq/m3) Liquid Scintillation Counting (LSC)"},{"_id":"6a5a55ef9af9f73f38250aae","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Wyroby, materiały budowlane Wyroby i materiały konstrukcyjne Building products, materials Construction products and materials Odpady O) / Waste O): 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 07*, 01 04 08, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 09 02, 19 09 04","test_object_en":"Building products, materials Construction products and materials Waste O): 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 07*, 01 04 08, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 09 02, 19 09 04","methodology":"Stężenie aktywności radionuklidu: 40K Zakres: (10 – 1 000 000) Bq/kg Metoda spektrometrii promieniowania gamma Activity concentration of radionuclide: 40K Range: (10 – 1 000 000) Bq/kg Gamma-ray spectrometry","methodology_en":"Activity concentration of radionuclide: 40K Range: (10 – 1 000 000) Bq/kg Gamma-ray spectrometry","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidu: 40K Zakres: (10 – 1 000 000) Bq/kg Metoda spektrometrii promieniowania gamma Activity concentration of radionuclide: 40K Range: (10 – 1 000 000) Bq/kg Gamma-ray spectrometry","reference":"Procedura SCR/ZLGIG/2-004 edycja 8 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/2-004 8th edition of 25 August 2023","norm_bases":["Procedura SCR/ZLGIG/2-004 edycja 8 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/2-004 8th edition of 25 August 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby, materiały budowlane Wyroby i materiały konstrukcyjne Building products, materials Construction products and materials Odpady O) / Waste O): 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 07*, 01 04 08, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 09 02, 19 09 04 Stężenie aktywności radionuklidu: 40K Zakres: (10 – 1 000 000) Bq/kg Metoda spektrometrii promieniowania gamma Activity concentration of radionuclide: 40K Range: (10 – 1 000 000) Bq/kg Gamma-ray spectrometry Procedura SCR/ZLGIG/2-004 edycja 8 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/2-004 8th edition of 25 August 2023 Wyroby, materialy budowlane Wyroby i materialy konstrukcyjne Building products, materials Construction products and materials Odpady O) / Waste O): 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 07*, 01 04 08, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 09 02, 19 09 04 Stezenie aktywnosci radionuklidu: 40K Zakres: (10 – 1 000 000) Bq/kg Metoda spektrometrii promieniowania gamma Activity concentration of radionuclide: 40K Range: (10 – 1 000 000) Bq/kg Gamma-ray spectrometry Procedura SCR/ZLGIG/2-004 edycja 8 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/2-004 8th edition of 25 August 2023","categories":["materials","environment","construction"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building products, materials Construction products and materials Waste O): 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 07*, 01 04 08, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 09 02, 19 09 04 Activity concentration of radionuclide: 40K Range: (10 – 1 000 000) Bq/kg Gamma-ray spectrometry Procedura SCR/ZLGIG/2-004 edycja 8 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/2-004 8th edition of 25 August 2023","search_zh":"建筑制品、建筑材料；结构制品与材料 Building products, materials Construction products and materials 废物 O) / Waste O)：01 01 01、01 01 02、01 01 80、01 03 05*、01 03 07*、01 03 09、01 03 80*、01 03 81、01 04 07*、01 04 08、01 04 80*、02 01 01、02 01 10、02 02 04、03 01 82、04 02 19*、05 01 09*、06 13 02*、10 01 01、10 01 02、10 01 03、10 01 04*、10 Procedura SCR/ZLGIG/2-004 edycja 8 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/2-004 8th edition of 25 August 2023","test_object_zh":"建筑制品、建筑材料；结构制品与材料 Building products, materials Construction products and materials 废物 O) / Waste O)：01 01 01、01 01 02、01 01 80、01 03 05*、01 03 07*、01 03 09、01 03 80*、01 03 81、01 04 07*、01 04 08、01 04 80*、02 01 01、02 01 10、02 02 04、03 01 82、04 02 19*、05 01 09*、06 13 02*、10 01 01、10 01 02、10 01 03、10 01 04*、10"},{"_id":"6a5a55ef9af9f73f38250aaf","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Wyroby, materiały budowlane Wyroby i materiały konstrukcyjne Building products, materials Construction products and materials Odpady O) / Waste O): 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 07*, 01 04 08, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 09 02, 19 09 04","test_object_en":"Building products, materials Construction products and materials Waste O): 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 07*, 01 04 08, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 09 02, 19 09 04","methodology":"Stężenie aktywności radionuklidu: 226Ra Zakres: (1,0 – 1 000 000) Bq/kg Metoda spektrometrii promieniowania gamma Activity concentration of radionuclide: 226Ra Range: (1,0 – 1 000 000) Bq/kg Gamma-ray spectrometry","methodology_en":"Activity concentration of radionuclide: 226Ra Range: (1,0 – 1 000 000) Bq/kg Gamma-ray spectrometry","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidu: 226Ra Zakres: (1,0 – 1 000 000) Bq/kg Metoda spektrometrii promieniowania gamma Activity concentration of radionuclide: 226Ra Range: (1,0 – 1 000 000) Bq/kg Gamma-ray spectrometry","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby, materiały budowlane Wyroby i materiały konstrukcyjne Building products, materials Construction products and materials Odpady O) / Waste O): 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 07*, 01 04 08, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 09 02, 19 09 04 Stężenie aktywności radionuklidu: 226Ra Zakres: (1,0 – 1 000 000) Bq/kg Metoda spektrometrii promieniowania gamma Activity concentration of radionuclide: 226Ra Range: (1,0 – 1 000 000) Bq/kg Gamma-ray spectrometry Wyroby, materialy budowlane Wyroby i materialy konstrukcyjne Building products, materials Construction products and materials Odpady O) / Waste O): 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 07*, 01 04 08, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 09 02, 19 09 04 Stezenie aktywnosci radionuklidu: 226Ra Zakres: (1,0 – 1 000 000) Bq/kg Metoda spektrometrii promieniowania gamma Activity concentration of radionuclide: 226Ra Range: (1,0 – 1 000 000) Bq/kg Gamma-ray spectrometry","categories":["materials","environment","construction"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building products, materials Construction products and materials Waste O): 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 07*, 01 04 08, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 09 02, 19 09 04 Activity concentration of radionuclide: 226Ra Range: (1,0 – 1 000 000) Bq/kg Gamma-ray spectrometry","search_zh":"建筑制品、建筑材料；结构制品与材料 Building products, materials Construction products and materials 废物 O) / Waste O)：01 01 01、01 01 02、01 01 80、01 03 05*、01 03 07*、01 03 09、01 03 80*、01 03 81、01 04 07*、01 04 08、01 04 80*、02 01 01、02 01 10、02 02 04、03 01 82、04 02 19*、05 01 09*、06 13 02*、10 01 01、10 01 02、10 01 03、10 01 04*、10","test_object_zh":"建筑制品、建筑材料；结构制品与材料 Building products, materials Construction products and materials 废物 O) / Waste O)：01 01 01、01 01 02、01 01 80、01 03 05*、01 03 07*、01 03 09、01 03 80*、01 03 81、01 04 07*、01 04 08、01 04 80*、02 01 01、02 01 10、02 02 04、03 01 82、04 02 19*、05 01 09*、06 13 02*、10 01 01、10 01 02、10 01 03、10 01 04*、10"},{"_id":"6a5a55ef9af9f73f38250ab0","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Wyroby, materiały budowlane Wyroby i materiały konstrukcyjne Building products, materials Construction products and materials Odpady O) / Waste O): 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 07*, 01 04 08, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 09 02, 19 09 04","test_object_en":"Building products, materials Construction products and materials Waste O): 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 07*, 01 04 08, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 09 02, 19 09 04","methodology":"Stężenie aktywności radionuklidu: 208Tl Zakres: (1 – 1 000 000) Bq/kg Metoda spektrometrii promieniowania Gamma Activity concentration of radionuclide: 208Tl Range: (1 – 1 000 000) Bq/kg Gamma-ray spectrometry","methodology_en":"Activity concentration of radionuclide: 208Tl Range: (1 – 1 000 000) Bq/kg Gamma-ray spectrometry","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidu: 208Tl Zakres: (1 – 1 000 000) Bq/kg Metoda spektrometrii promieniowania Gamma Activity concentration of radionuclide: 208Tl Range: (1 – 1 000 000) Bq/kg Gamma-ray spectrometry","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby, materiały budowlane Wyroby i materiały konstrukcyjne Building products, materials Construction products and materials Odpady O) / Waste O): 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 07*, 01 04 08, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 09 02, 19 09 04 Stężenie aktywności radionuklidu: 208Tl Zakres: (1 – 1 000 000) Bq/kg Metoda spektrometrii promieniowania Gamma Activity concentration of radionuclide: 208Tl Range: (1 – 1 000 000) Bq/kg Gamma-ray spectrometry Wyroby, materialy budowlane Wyroby i materialy konstrukcyjne Building products, materials Construction products and materials Odpady O) / Waste O): 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 07*, 01 04 08, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 09 02, 19 09 04 Stezenie aktywnosci radionuklidu: 208Tl Zakres: (1 – 1 000 000) Bq/kg Metoda spektrometrii promieniowania Gamma Activity concentration of radionuclide: 208Tl Range: (1 – 1 000 000) Bq/kg Gamma-ray spectrometry","categories":["materials","environment","construction"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building products, materials Construction products and materials Waste O): 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 07*, 01 04 08, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 09 02, 19 09 04 Activity concentration of radionuclide: 208Tl Range: (1 – 1 000 000) Bq/kg Gamma-ray spectrometry","search_zh":"建筑制品、建筑材料；结构制品与材料 Building products, materials Construction products and materials 废物 O) / Waste O)：01 01 01、01 01 02、01 01 80、01 03 05*、01 03 07*、01 03 09、01 03 80*、01 03 81、01 04 07*、01 04 08、01 04 80*、02 01 01、02 01 10、02 02 04、03 01 82、04 02 19*、05 01 09*、06 13 02*、10 01 01、10 01 02、10 01 03、10 01 04*、10","test_object_zh":"建筑制品、建筑材料；结构制品与材料 Building products, materials Construction products and materials 废物 O) / Waste O)：01 01 01、01 01 02、01 01 80、01 03 05*、01 03 07*、01 03 09、01 03 80*、01 03 81、01 04 07*、01 04 08、01 04 80*、02 01 01、02 01 10、02 02 04、03 01 82、04 02 19*、05 01 09*、06 13 02*、10 01 01、10 01 02、10 01 03、10 01 04*、10"},{"_id":"6a5a55ef9af9f73f38250ab1","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Wyroby, materiały budowlane Wyroby i materiały konstrukcyjne Building products, materials Construction products and materials Odpady O) / Waste O): 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 07*, 01 04 08, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 09 02, 19 09 04","test_object_en":"Building products, materials Construction products and materials Waste O): 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 07*, 01 04 08, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 09 02, 19 09 04","methodology":"Stężenie aktywności radionuklidu: 232Th (z obliczeń) Activity concentration of radionuclide: 232Th (calculated)","methodology_en":"Activity concentration of radionuclide: 232Th (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidu: 232Th (z obliczeń) Activity concentration of radionuclide: 232Th (calculated)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby, materiały budowlane Wyroby i materiały konstrukcyjne Building products, materials Construction products and materials Odpady O) / Waste O): 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 07*, 01 04 08, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 09 02, 19 09 04 Stężenie aktywności radionuklidu: 232Th (z obliczeń) Activity concentration of radionuclide: 232Th (calculated) Wyroby, materialy budowlane Wyroby i materialy konstrukcyjne Building products, materials Construction products and materials Odpady O) / Waste O): 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 07*, 01 04 08, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 09 02, 19 09 04 Stezenie aktywnosci radionuklidu: 232Th (z obliczen) Activity concentration of radionuclide: 232Th (calculated)","categories":["materials","environment","construction"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building products, materials Construction products and materials Waste O): 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 07*, 01 04 08, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 09 02, 19 09 04 Activity concentration of radionuclide: 232Th (calculated)","search_zh":"建筑制品、建筑材料；结构制品与材料 Building products, materials Construction products and materials 废物 O) / Waste O)：01 01 01、01 01 02、01 01 80、01 03 05*、01 03 07*、01 03 09、01 03 80*、01 03 81、01 04 07*、01 04 08、01 04 80*、02 01 01、02 01 10、02 02 04、03 01 82、04 02 19*、05 01 09*、06 13 02*、10 01 01、10 01 02、10 01 03、10 01 04*、10","test_object_zh":"建筑制品、建筑材料；结构制品与材料 Building products, materials Construction products and materials 废物 O) / Waste O)：01 01 01、01 01 02、01 01 80、01 03 05*、01 03 07*、01 03 09、01 03 80*、01 03 81、01 04 07*、01 04 08、01 04 80*、02 01 01、02 01 10、02 02 04、03 01 82、04 02 19*、05 01 09*、06 13 02*、10 01 01、10 01 02、10 01 03、10 01 04*、10"},{"_id":"6a5a55ef9af9f73f38250ab2","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Wyroby, materiały budowlane Wyroby i materiały konstrukcyjne Building products, materials Construction products and materials Odpady O) / Waste O): 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 07*, 01 04 08, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 09 02, 19 09 04","test_object_en":"Building products, materials Construction products and materials Waste O): 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 07*, 01 04 08, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 09 02, 19 09 04","methodology":"Wskaźnik stężenia promieniotwórczego I (z obliczeń) Activity concentration index I (calculated)","methodology_en":"Activity concentration index I (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik stężenia promieniotwórczego I (z obliczeń) Activity concentration index I (calculated)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby, materiały budowlane Wyroby i materiały konstrukcyjne Building products, materials Construction products and materials Odpady O) / Waste O): 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 07*, 01 04 08, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 09 02, 19 09 04 Wskaźnik stężenia promieniotwórczego I (z obliczeń) Activity concentration index I (calculated) Wyroby, materialy budowlane Wyroby i materialy konstrukcyjne Building products, materials Construction products and materials Odpady O) / Waste O): 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 07*, 01 04 08, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 09 02, 19 09 04 Wskaznik stezenia promieniotworczego I (z obliczen) Activity concentration index I (calculated)","categories":["materials","environment","construction"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building products, materials Construction products and materials Waste O): 01 01 01, 01 01 02, 01 01 80, 01 03 05*, 01 03 07*, 01 03 09, 01 03 80*, 01 03 81, 01 04 07*, 01 04 08, 01 04 80*, 02 01 01, 02 01 10, 02 02 04, 03 01 82, 04 02 19*, 05 01 09*, 06 13 02*, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 03 04*, 10 03 19*, 10 03 20, 10 03 23*, 10 03 24, 10 03 25*, 17 01 01, 17 01 02, 17 01 03, 17 01 06, 10 01 07, 17 01 82, 17 02 02, 17 05 03, 17 05 04, 17 05 05*, 17 05 06, 17 05 08, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 09 02, 19 09 04 Activity concentration index I (calculated)","search_zh":"建筑制品、建筑材料；结构制品与材料 Building products, materials Construction products and materials 废物 O) / Waste O)：01 01 01、01 01 02、01 01 80、01 03 05*、01 03 07*、01 03 09、01 03 80*、01 03 81、01 04 07*、01 04 08、01 04 80*、02 01 01、02 01 10、02 02 04、03 01 82、04 02 19*、05 01 09*、06 13 02*、10 01 01、10 01 02、10 01 03、10 01 04*、10","test_object_zh":"建筑制品、建筑材料；结构制品与材料 Building products, materials Construction products and materials 废物 O) / Waste O)：01 01 01、01 01 02、01 01 80、01 03 05*、01 03 07*、01 03 09、01 03 80*、01 03 81、01 04 07*、01 04 08、01 04 80*、02 01 01、02 01 10、02 02 04、03 01 82、04 02 19*、05 01 09*、06 13 02*、10 01 01、10 01 02、10 01 03、10 01 04*、10"},{"_id":"6a5a55ef9af9f73f38250ab3","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Gleba, grunty, skały Osady Powietrze Obiekty i materiały biologiczne (ludzkie, zwierzęce, roślinne i inne naturalne) Żywność Produkty rolne Pasze dla zwierząt Soil, ground, rocks Sediments Air Biological items and materials (human, animal, vegetable and other natural) Food Agricultural products Animal feedstuffs","test_object_en":"Soil, ground, rocks Sediments Air Biological items and materials (human, animal, vegetable and other natural) Food Agricultural products Animal feedstuffs","methodology":"Obliczanie skutecznej dawki obciążającej dla jednostkowego wniknięcia badanego materiału Calculation of committed effective dose from intake of radioactive material","methodology_en":"Calculation of committed effective dose for unit intake of the tested material Calculation of committed effective dose from intake of radioactive material","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Obliczanie skutecznej dawki obciążającej dla jednostkowego wniknięcia badanego materiału Calculation of committed effective dose from intake of radioactive material","reference":"Procedura SCR/ZLGIG/2-005 edycja 3 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/2-005 3rd edition of 25 August 2023","norm_bases":["Procedura SCR/ZLGIG/2-005 edycja 3 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/2-005 3rd edition of 25 August 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba, grunty, skały Osady Powietrze Obiekty i materiały biologiczne (ludzkie, zwierzęce, roślinne i inne naturalne) Żywność Produkty rolne Pasze dla zwierząt Soil, ground, rocks Sediments Air Biological items and materials (human, animal, vegetable and other natural) Food Agricultural products Animal feedstuffs Obliczanie skutecznej dawki obciążającej dla jednostkowego wniknięcia badanego materiału Calculation of committed effective dose from intake of radioactive material Procedura SCR/ZLGIG/2-005 edycja 3 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/2-005 3rd edition of 25 August 2023 Gleba, grunty, skaly Osady Powietrze Obiekty i materialy biologiczne (ludzkie, zwierzece, roslinne i inne naturalne) Zywnosc Produkty rolne Pasze dla zwierzat Soil, ground, rocks Sediments Air Biological items and materials (human, animal, vegetable and other natural) Food Agricultural products Animal feedstuffs Obliczanie skutecznej dawki obciazajacej dla jednostkowego wnikniecia badanego materialu Calculation of committed effective dose from intake of radioactive material Procedura SCR/ZLGIG/2-005 edycja 3 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/2-005 3rd edition of 25 August 2023","categories":["food","materials","environment","water"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil, ground, rocks Sediments Air Biological items and materials (human, animal, vegetable and other natural) Food Agricultural products Animal feedstuffs Calculation of committed effective dose for unit intake of the tested material Calculation of committed effective dose from intake of radioactive material Procedura SCR/ZLGIG/2-005 edycja 3 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/2-005 3rd edition of 25 August 2023"},{"_id":"6a5a55ef9af9f73f38250ab4","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Wyroby inne - Dawkomierze w polu promieniowania Other products - Dosimeters in radiation field","test_object_en":"Other products - Dosimeters in radiation field","methodology":"Kerma promieniowania fotonowego Zakres: 3 μGy – 5 Gy Metoda dozymetrii termoluminescencyjnej (TLD) Kerma of photon radiation Range: 3 μGy – 5 Gy Thermoluminescency (TLD)","methodology_en":"Kerma of photon radiation Range: 3 μGy – 5 Gy Thermoluminescency (TLD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Kerma promieniowania fotonowego Zakres: 3 μGy – 5 Gy Metoda dozymetrii termoluminescencyjnej (TLD) Kerma of photon radiation Range: 3 μGy – 5 Gy Thermoluminescency (TLD)","reference":"Procedura SCR /ZLGIG/3-003 edycja 4 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/3-003 4th edition of 25 August 2023","norm_bases":["Procedura SCR /ZLGIG/3-003 edycja 4 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/3-003 4th edition of 25 August 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby inne - Dawkomierze w polu promieniowania Other products - Dosimeters in radiation field Kerma promieniowania fotonowego Zakres: 3 μGy – 5 Gy Metoda dozymetrii termoluminescencyjnej (TLD) Kerma of photon radiation Range: 3 μGy – 5 Gy Thermoluminescency (TLD) Procedura SCR /ZLGIG/3-003 edycja 4 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/3-003 4th edition of 25 August 2023 Wyroby inne - Dawkomierze w polu promieniowania Other products - Dosimeters in radiation field Kerma promieniowania fotonowego Zakres: 3 μGy – 5 Gy Metoda dozymetrii termoluminescencyjnej (TLD) Kerma of photon radiation Range: 3 μGy – 5 Gy Thermoluminescency (TLD) Procedura SCR /ZLGIG/3-003 edycja 4 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/3-003 4th edition of 25 August 2023","categories":["other"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Other products - Dosimeters in radiation field Kerma of photon radiation Range: 3 μGy – 5 Gy Thermoluminescency (TLD) Procedura SCR /ZLGIG/3-003 edycja 4 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/3-003 4th edition of 25 August 2023","search_zh":"其他制品 － 辐射场中的剂量计 Other products - Dosimeters in radiation field Procedura SCR /ZLGIG/3-003 edycja 4 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/3-003 4th edition of 25 August 2023","test_object_zh":"其他制品 － 辐射场中的剂量计 Other products - Dosimeters in radiation field"},{"_id":"6a5a55ef9af9f73f38250ab5","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Wyroby inne - Dawkomierze w polu promieniowania Other products - Dosimeters in radiation field","test_object_en":"Other products - Dosimeters in radiation field","methodology":"Indywidualny równoważnik dawki H(10) p Zakres: 3 μSv – 5 Sv Metoda dozymetrii termoluminescencyjnej (TLD) Individual equivalent dose H(10) p Range: 3 μSv – 5 Sv Thermoluminescency (TLD)","methodology_en":"Individual equivalent dose H(10) p Range: 3 μSv – 5 Sv Thermoluminescency (TLD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indywidualny równoważnik dawki H(10) p Zakres: 3 μSv – 5 Sv Metoda dozymetrii termoluminescencyjnej (TLD) Individual equivalent dose H(10) p Range: 3 μSv – 5 Sv Thermoluminescency (TLD)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby inne - Dawkomierze w polu promieniowania Other products - Dosimeters in radiation field Indywidualny równoważnik dawki H(10) p Zakres: 3 μSv – 5 Sv Metoda dozymetrii termoluminescencyjnej (TLD) Individual equivalent dose H(10) p Range: 3 μSv – 5 Sv Thermoluminescency (TLD) Wyroby inne - Dawkomierze w polu promieniowania Other products - Dosimeters in radiation field Indywidualny rownowaznik dawki H(10) p Zakres: 3 μSv – 5 Sv Metoda dozymetrii termoluminescencyjnej (TLD) Individual equivalent dose H(10) p Range: 3 μSv – 5 Sv Thermoluminescency (TLD)","categories":["other"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Other products - Dosimeters in radiation field Individual equivalent dose H(10) p Range: 3 μSv – 5 Sv Thermoluminescency (TLD)","search_zh":"其他制品 － 辐射场中的剂量计 Other products - Dosimeters in radiation field","test_object_zh":"其他制品 － 辐射场中的剂量计 Other products - Dosimeters in radiation field"},{"_id":"6a5a55ef9af9f73f38250ab6","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Wyroby inne - Dawkomierze w polu promieniowania Other products - Dosimeters in radiation field","test_object_en":"Other products - Dosimeters in radiation field","methodology":"Przestrzenny równoważnik dawki H*(10) Zakres: 3 μSv – 5 Sv Metoda dozymetrii termoluminescencyjnej (TLD) Ambient equivalent dose H*(10) Range: 3 μSv – 5 Sv Thermoluminescency (TLD)","methodology_en":"Ambient equivalent dose H*(10) Range: 3 μSv – 5 Sv Thermoluminescency (TLD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przestrzenny równoważnik dawki H*(10) Zakres: 3 μSv – 5 Sv Metoda dozymetrii termoluminescencyjnej (TLD) Ambient equivalent dose H*(10) Range: 3 μSv – 5 Sv Thermoluminescency (TLD)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby inne - Dawkomierze w polu promieniowania Other products - Dosimeters in radiation field Przestrzenny równoważnik dawki H*(10) Zakres: 3 μSv – 5 Sv Metoda dozymetrii termoluminescencyjnej (TLD) Ambient equivalent dose H*(10) Range: 3 μSv – 5 Sv Thermoluminescency (TLD) Wyroby inne - Dawkomierze w polu promieniowania Other products - Dosimeters in radiation field Przestrzenny rownowaznik dawki H*(10) Zakres: 3 μSv – 5 Sv Metoda dozymetrii termoluminescencyjnej (TLD) Ambient equivalent dose H*(10) Range: 3 μSv – 5 Sv Thermoluminescency (TLD)","categories":["other"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Other products - Dosimeters in radiation field Ambient equivalent dose H*(10) Range: 3 μSv – 5 Sv Thermoluminescency (TLD)","search_zh":"其他制品 － 辐射场中的剂量计 Other products - Dosimeters in radiation field","test_object_zh":"其他制品 － 辐射场中的剂量计 Other products - Dosimeters in radiation field"},{"_id":"6a5a55ef9af9f73f38250ab7","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Wyroby inne - Dawkomierze w polu promieniowania Other products - Dosimeters in radiation field","test_object_en":"Other products - Dosimeters in radiation field","methodology":"Kerma promieniowania fotonowego w zakresie energii: 10 keV – 10 MeV Zakres: 10 μGy – 10 Gy Metoda dozymetrii termoluminescencyjnej (TLD) Kerma of photon radiation in range of energy: 10 keV – 10 MeV Range: 10 μGy – 10 Gy Thermoluminescency (TLD)","methodology_en":"Kerma of photon radiation in range of energy: 10 keV – 10 MeV Range: 10 μGy – 10 Gy Thermoluminescency (TLD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Kerma promieniowania fotonowego w zakresie energii: 10 keV – 10 MeV Zakres: 10 μGy – 10 Gy Metoda dozymetrii termoluminescencyjnej (TLD) Kerma of photon radiation in range of energy: 10 keV – 10 MeV Range: 10 μGy – 10 Gy Thermoluminescency (TLD)","reference":"Procedura SCR/ZLGIG/3-010 edycja 5 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/3-010 5th edition of 25 August 2023","norm_bases":["Procedura SCR/ZLGIG/3-010 edycja 5 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/3-010 5th edition of 25 August 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby inne - Dawkomierze w polu promieniowania Other products - Dosimeters in radiation field Kerma promieniowania fotonowego w zakresie energii: 10 keV – 10 MeV Zakres: 10 μGy – 10 Gy Metoda dozymetrii termoluminescencyjnej (TLD) Kerma of photon radiation in range of energy: 10 keV – 10 MeV Range: 10 μGy – 10 Gy Thermoluminescency (TLD) Procedura SCR/ZLGIG/3-010 edycja 5 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/3-010 5th edition of 25 August 2023 Wyroby inne - Dawkomierze w polu promieniowania Other products - Dosimeters in radiation field Kerma promieniowania fotonowego w zakresie energii: 10 keV – 10 MeV Zakres: 10 μGy – 10 Gy Metoda dozymetrii termoluminescencyjnej (TLD) Kerma of photon radiation in range of energy: 10 keV – 10 MeV Range: 10 μGy – 10 Gy Thermoluminescency (TLD) Procedura SCR/ZLGIG/3-010 edycja 5 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/3-010 5th edition of 25 August 2023","categories":["other"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Other products - Dosimeters in radiation field Kerma of photon radiation in range of energy: 10 keV – 10 MeV Range: 10 μGy – 10 Gy Thermoluminescency (TLD) Procedura SCR/ZLGIG/3-010 edycja 5 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/3-010 5th edition of 25 August 2023","search_zh":"其他制品 － 辐射场中的剂量计 Other products - Dosimeters in radiation field Procedura SCR/ZLGIG/3-010 edycja 5 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/3-010 5th edition of 25 August 2023","test_object_zh":"其他制品 － 辐射场中的剂量计 Other products - Dosimeters in radiation field"},{"_id":"6a5a55ef9af9f73f38250ab8","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Wyroby inne - Dawkomierze w polu promieniowania Other products - Dosimeters in radiation field","test_object_en":"Other products - Dosimeters in radiation field","methodology":"Moc kermy promieniowania fotonowego w zakresie energii: 10 keV – 10 MeV Zakres: 5 nGy/h – 5 Gy/h Metoda dozymetrii termoluminescencyjnej (TLD) Kerma rate of photon radiation in energy range: 10 keV – 10 MeV Range: 5 nGy/h – 5 Gy/h Thermoluminescency (TLD)","methodology_en":"Kerma rate of photon radiation in energy range: 10 keV – 10 MeV Range: 5 nGy/h – 5 Gy/h Thermoluminescency (TLD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moc kermy promieniowania fotonowego w zakresie energii: 10 keV – 10 MeV Zakres: 5 nGy/h – 5 Gy/h Metoda dozymetrii termoluminescencyjnej (TLD) Kerma rate of photon radiation in energy range: 10 keV – 10 MeV Range: 5 nGy/h – 5 Gy/h Thermoluminescency (TLD)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby inne - Dawkomierze w polu promieniowania Other products - Dosimeters in radiation field Moc kermy promieniowania fotonowego w zakresie energii: 10 keV – 10 MeV Zakres: 5 nGy/h – 5 Gy/h Metoda dozymetrii termoluminescencyjnej (TLD) Kerma rate of photon radiation in energy range: 10 keV – 10 MeV Range: 5 nGy/h – 5 Gy/h Thermoluminescency (TLD) Wyroby inne - Dawkomierze w polu promieniowania Other products - Dosimeters in radiation field Moc kermy promieniowania fotonowego w zakresie energii: 10 keV – 10 MeV Zakres: 5 nGy/h – 5 Gy/h Metoda dozymetrii termoluminescencyjnej (TLD) Kerma rate of photon radiation in energy range: 10 keV – 10 MeV Range: 5 nGy/h – 5 Gy/h Thermoluminescency (TLD)","categories":["other"],"row_index":28,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Other products - Dosimeters in radiation field Kerma rate of photon radiation in energy range: 10 keV – 10 MeV Range: 5 nGy/h – 5 Gy/h Thermoluminescency (TLD)","search_zh":"其他制品 － 辐射场中的剂量计 Other products - Dosimeters in radiation field","test_object_zh":"其他制品 － 辐射场中的剂量计 Other products - Dosimeters in radiation field"},{"_id":"6a5a55ef9af9f73f38250ab9","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Wyroby inne - Dawkomierze w polu promieniowania Other products - Dosimeters in radiation field","test_object_en":"Other products - Dosimeters in radiation field","methodology":"Indywidualny równoważnik dawki H (10) promieniowania fotonowego p w zakresie energii: 10 keV – 10 MeV Zakres: 10 μSv – 10 Sv Metoda dozymetrii termoluminescencyjnej (TLD) Individual equivalent dose H (10) of photon radiation in energy p range 10 keV – 10 MeV Range: 10 μSv – 10 Sv Thermoluminescency (TLD)","methodology_en":"Individual equivalent dose H (10) of photon radiation in energy p range 10 keV – 10 MeV Range: 10 μSv – 10 Sv Thermoluminescency (TLD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indywidualny równoważnik dawki H (10) promieniowania fotonowego p w zakresie energii: 10 keV – 10 MeV Zakres: 10 μSv – 10 Sv Metoda dozymetrii termoluminescencyjnej (TLD) Individual equivalent dose H (10) of photon radiation in energy p range 10 keV – 10 MeV Range: 10 μSv – 10 Sv Thermoluminescency (TLD)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby inne - Dawkomierze w polu promieniowania Other products - Dosimeters in radiation field Indywidualny równoważnik dawki H (10) promieniowania fotonowego p w zakresie energii: 10 keV – 10 MeV Zakres: 10 μSv – 10 Sv Metoda dozymetrii termoluminescencyjnej (TLD) Individual equivalent dose H (10) of photon radiation in energy p range 10 keV – 10 MeV Range: 10 μSv – 10 Sv Thermoluminescency (TLD) Wyroby inne - Dawkomierze w polu promieniowania Other products - Dosimeters in radiation field Indywidualny rownowaznik dawki H (10) promieniowania fotonowego p w zakresie energii: 10 keV – 10 MeV Zakres: 10 μSv – 10 Sv Metoda dozymetrii termoluminescencyjnej (TLD) Individual equivalent dose H (10) of photon radiation in energy p range 10 keV – 10 MeV Range: 10 μSv – 10 Sv Thermoluminescency (TLD)","categories":["other"],"row_index":29,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Other products - Dosimeters in radiation field Individual equivalent dose H (10) of photon radiation in energy p range 10 keV – 10 MeV Range: 10 μSv – 10 Sv Thermoluminescency (TLD)","search_zh":"其他制品 － 辐射场中的剂量计 Other products - Dosimeters in radiation field","test_object_zh":"其他制品 － 辐射场中的剂量计 Other products - Dosimeters in radiation field"},{"_id":"6a5a55ef9af9f73f38250aba","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Wyroby inne - Dawkomierze w polu promieniowania Other products - Dosimeters in radiation field","test_object_en":"Other products - Dosimeters in radiation field","methodology":"Indywidualny równoważnik dawki H (0,07) promieniowania fotonowego p i promieniowania beta w zakresie energii: 10 keV – 10 MeV Zakres: 0,1 mSv – 1 Sv Metoda dozymetrii termoluminescencyjnej (TLD) Individual equivalent dose H (0,07) of photon and beta radiation in p energy range 10 keV – 10 MeV Range: 0,1 mSv – 1 Sv Thermoluminescency (TLD)","methodology_en":"Individual equivalent dose H (0,07) of photon and beta radiation in p energy range 10 keV – 10 MeV Range: 0,1 mSv – 1 Sv Thermoluminescency (TLD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indywidualny równoważnik dawki H (0,07) promieniowania fotonowego p i promieniowania beta w zakresie energii: 10 keV – 10 MeV Zakres: 0,1 mSv – 1 Sv Metoda dozymetrii termoluminescencyjnej (TLD) Individual equivalent dose H (0,07) of photon and beta radiation in p energy range 10 keV – 10 MeV Range: 0,1 mSv – 1 Sv Thermoluminescency (TLD)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby inne - Dawkomierze w polu promieniowania Other products - Dosimeters in radiation field Indywidualny równoważnik dawki H (0,07) promieniowania fotonowego p i promieniowania beta w zakresie energii: 10 keV – 10 MeV Zakres: 0,1 mSv – 1 Sv Metoda dozymetrii termoluminescencyjnej (TLD) Individual equivalent dose H (0,07) of photon and beta radiation in p energy range 10 keV – 10 MeV Range: 0,1 mSv – 1 Sv Thermoluminescency (TLD) Wyroby inne - Dawkomierze w polu promieniowania Other products - Dosimeters in radiation field Indywidualny rownowaznik dawki H (0,07) promieniowania fotonowego p i promieniowania beta w zakresie energii: 10 keV – 10 MeV Zakres: 0,1 mSv – 1 Sv Metoda dozymetrii termoluminescencyjnej (TLD) Individual equivalent dose H (0,07) of photon and beta radiation in p energy range 10 keV – 10 MeV Range: 0,1 mSv – 1 Sv Thermoluminescency (TLD)","categories":["other"],"row_index":30,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Other products - Dosimeters in radiation field Individual equivalent dose H (0,07) of photon and beta radiation in p energy range 10 keV – 10 MeV Range: 0,1 mSv – 1 Sv Thermoluminescency (TLD)","search_zh":"其他制品 － 辐射场中的剂量计 Other products - Dosimeters in radiation field","test_object_zh":"其他制品 － 辐射场中的剂量计 Other products - Dosimeters in radiation field"},{"_id":"6a5a55ef9af9f73f38250abb","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Wyroby inne - Dawkomierze w polu promieniowania Other products - Dosimeters in radiation field","test_object_en":"Other products - Dosimeters in radiation field","methodology":"Indywidualny równoważnik dawki H(3) p promieniowania fotonowego w zakresie energii: 10 keV – 10 MeV Zakres: 0,1 mSv – 1 Sv Metoda dozymetrii termoluminescencyjnej (TLD) Individual equivalent dose H (3) of photon radiation in energy range: p 10 keV – 10 MeV Range: 0,1 mSv – 1 Sv Thermoluminescency (TLD)","methodology_en":"Individual equivalent dose H (3) of photon radiation in energy range: p 10 keV – 10 MeV Range: 0,1 mSv – 1 Sv Thermoluminescency (TLD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indywidualny równoważnik dawki H(3) p promieniowania fotonowego w zakresie energii: 10 keV – 10 MeV Zakres: 0,1 mSv – 1 Sv Metoda dozymetrii termoluminescencyjnej (TLD) Individual equivalent dose H (3) of photon radiation in energy range: p 10 keV – 10 MeV Range: 0,1 mSv – 1 Sv Thermoluminescency (TLD)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby inne - Dawkomierze w polu promieniowania Other products - Dosimeters in radiation field Indywidualny równoważnik dawki H(3) p promieniowania fotonowego w zakresie energii: 10 keV – 10 MeV Zakres: 0,1 mSv – 1 Sv Metoda dozymetrii termoluminescencyjnej (TLD) Individual equivalent dose H (3) of photon radiation in energy range: p 10 keV – 10 MeV Range: 0,1 mSv – 1 Sv Thermoluminescency (TLD) Wyroby inne - Dawkomierze w polu promieniowania Other products - Dosimeters in radiation field Indywidualny rownowaznik dawki H(3) p promieniowania fotonowego w zakresie energii: 10 keV – 10 MeV Zakres: 0,1 mSv – 1 Sv Metoda dozymetrii termoluminescencyjnej (TLD) Individual equivalent dose H (3) of photon radiation in energy range: p 10 keV – 10 MeV Range: 0,1 mSv – 1 Sv Thermoluminescency (TLD)","categories":["other"],"row_index":31,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Other products - Dosimeters in radiation field Individual equivalent dose H (3) of photon radiation in energy range: p 10 keV – 10 MeV Range: 0,1 mSv – 1 Sv Thermoluminescency (TLD)","search_zh":"其他制品 － 辐射场中的剂量计 Other products - Dosimeters in radiation field","test_object_zh":"其他制品 － 辐射场中的剂量计 Other products - Dosimeters in radiation field"},{"_id":"6a5a55ef9af9f73f38250abc","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Wyroby inne - Dawkomierze w polu promieniowania Filtr powietrza Other products - Dosimeters in radiation field Air filter","test_object_en":"Other products - Dosimeters in radiation field Air filter","methodology":"Przestrzenny równoważnik dawki H*(10) promieniowania fotonowego w zakresie energii: 10 keV – 10 MeV Zakres: 10 μSv – 10 Sv Metoda dozymetrii termoluminescencyjnej (TLD) Ambient equivalent dose H*(10) of photon radiation in energy range: 10 keV – 10 MeV Range: 10 μSv – 10 Sv Thermoluminescency (TLD)","methodology_en":"Ambient equivalent dose H*(10) of photon radiation in energy range: 10 keV – 10 MeV Range: 10 μSv – 10 Sv Thermoluminescency (TLD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przestrzenny równoważnik dawki H*(10) promieniowania fotonowego w zakresie energii: 10 keV – 10 MeV Zakres: 10 μSv – 10 Sv Metoda dozymetrii termoluminescencyjnej (TLD) Ambient equivalent dose H*(10) of photon radiation in energy range: 10 keV – 10 MeV Range: 10 μSv – 10 Sv Thermoluminescency (TLD)","reference":"Procedura SCR/ZLGIG/3-010 edycja 5 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/3-010 5th edition of 25 August 2023","norm_bases":["Procedura SCR/ZLGIG/3-010 edycja 5 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/3-010 5th edition of 25 August 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby inne - Dawkomierze w polu promieniowania Filtr powietrza Other products - Dosimeters in radiation field Air filter Przestrzenny równoważnik dawki H*(10) promieniowania fotonowego w zakresie energii: 10 keV – 10 MeV Zakres: 10 μSv – 10 Sv Metoda dozymetrii termoluminescencyjnej (TLD) Ambient equivalent dose H*(10) of photon radiation in energy range: 10 keV – 10 MeV Range: 10 μSv – 10 Sv Thermoluminescency (TLD) Procedura SCR/ZLGIG/3-010 edycja 5 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/3-010 5th edition of 25 August 2023 Wyroby inne - Dawkomierze w polu promieniowania Filtr powietrza Other products - Dosimeters in radiation field Air filter Przestrzenny rownowaznik dawki H*(10) promieniowania fotonowego w zakresie energii: 10 keV – 10 MeV Zakres: 10 μSv – 10 Sv Metoda dozymetrii termoluminescencyjnej (TLD) Ambient equivalent dose H*(10) of photon radiation in energy range: 10 keV – 10 MeV Range: 10 μSv – 10 Sv Thermoluminescency (TLD) Procedura SCR/ZLGIG/3-010 edycja 5 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/3-010 5th edition of 25 August 2023","categories":["other"],"row_index":32,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Other products - Dosimeters in radiation field Air filter Ambient equivalent dose H*(10) of photon radiation in energy range: 10 keV – 10 MeV Range: 10 μSv – 10 Sv Thermoluminescency (TLD) Procedura SCR/ZLGIG/3-010 edycja 5 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/3-010 5th edition of 25 August 2023","search_zh":"其他制品 － 辐射场中的剂量计 空气过滤器 Other products - Dosimeters in radiation field Air filter Procedura SCR/ZLGIG/3-010 edycja 5 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/3-010 5th edition of 25 August 2023","test_object_zh":"其他制品 － 辐射场中的剂量计 空气过滤器 Other products - Dosimeters in radiation field Air filter"},{"_id":"6a5a55ef9af9f73f38250abd","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Wyroby inne - Dawkomierze w polu promieniowania Filtr powietrza Other products - Dosimeters in radiation field Air filter","test_object_en":"Other products - Dosimeters in radiation field Air filter","methodology":"Moc przestrzennego równoważnika dawki promieniowania fotonowego w zakresie energii: 10 keV – 10 MeV Zakres: 5 nSv/h – 5 Sv/h Metoda dozymetrii termoluminescencyjnej (TLD) Ambient equivalent dose rate of photon radiation in energy range: 10 keV – 10 MeV Range: 5 nSv/h – 5 Sv/h Thermoluminescency (TLD)","methodology_en":"Ambient equivalent dose rate of photon radiation in energy range: 10 keV – 10 MeV Range: 5 nSv/h – 5 Sv/h Thermoluminescency (TLD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moc przestrzennego równoważnika dawki promieniowania fotonowego w zakresie energii: 10 keV – 10 MeV Zakres: 5 nSv/h – 5 Sv/h Metoda dozymetrii termoluminescencyjnej (TLD) Ambient equivalent dose rate of photon radiation in energy range: 10 keV – 10 MeV Range: 5 nSv/h – 5 Sv/h Thermoluminescency (TLD)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby inne - Dawkomierze w polu promieniowania Filtr powietrza Other products - Dosimeters in radiation field Air filter Moc przestrzennego równoważnika dawki promieniowania fotonowego w zakresie energii: 10 keV – 10 MeV Zakres: 5 nSv/h – 5 Sv/h Metoda dozymetrii termoluminescencyjnej (TLD) Ambient equivalent dose rate of photon radiation in energy range: 10 keV – 10 MeV Range: 5 nSv/h – 5 Sv/h Thermoluminescency (TLD) Wyroby inne - Dawkomierze w polu promieniowania Filtr powietrza Other products - Dosimeters in radiation field Air filter Moc przestrzennego rownowaznika dawki promieniowania fotonowego w zakresie energii: 10 keV – 10 MeV Zakres: 5 nSv/h – 5 Sv/h Metoda dozymetrii termoluminescencyjnej (TLD) Ambient equivalent dose rate of photon radiation in energy range: 10 keV – 10 MeV Range: 5 nSv/h – 5 Sv/h Thermoluminescency (TLD)","categories":["other"],"row_index":33,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Other products - Dosimeters in radiation field Air filter Ambient equivalent dose rate of photon radiation in energy range: 10 keV – 10 MeV Range: 5 nSv/h – 5 Sv/h Thermoluminescency (TLD)","search_zh":"其他制品 － 辐射场中的剂量计 空气过滤器 Other products - Dosimeters in radiation field Air filter","test_object_zh":"其他制品 － 辐射场中的剂量计 空气过滤器 Other products - Dosimeters in radiation field Air filter"},{"_id":"6a5a55ef9af9f73f38250abe","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Wyroby inne - Dawkomierze w polu promieniowania Filtr powietrza Other products - Dosimeters in radiation field Air filter","test_object_en":"Other products - Dosimeters in radiation field Air filter","methodology":"Energia potencjalna α krótkożyciowych produktów rozpadu radonu zgromadzonych na filtrze Zakres: (0,02 – 4000) μJ Metoda dozymetrii termoluminescencyjnej (TLD) Potential Alpha Energy of short-living radon decay products in air collected on filters Range: (0,02 – 4000) μJ Thermoluminescency (TLD)","methodology_en":"Potential Alpha Energy of short-living radon decay products in air collected on filters Range: (0,02 – 4000) μJ Thermoluminescency (TLD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Energia potencjalna α krótkożyciowych produktów rozpadu radonu zgromadzonych na filtrze Zakres: (0,02 – 4000) μJ Metoda dozymetrii termoluminescencyjnej (TLD) Potential Alpha Energy of short-living radon decay products in air collected on filters Range: (0,02 – 4000) μJ Thermoluminescency (TLD)","reference":"Procedura SCR/ZLGIG/3-001 edycja 4 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/3-001 4th edition of 25 August 2023","norm_bases":["Procedura SCR/ZLGIG/3-001 edycja 4 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/3-001 4th edition of 25 August 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby inne - Dawkomierze w polu promieniowania Filtr powietrza Other products - Dosimeters in radiation field Air filter Energia potencjalna α krótkożyciowych produktów rozpadu radonu zgromadzonych na filtrze Zakres: (0,02 – 4000) μJ Metoda dozymetrii termoluminescencyjnej (TLD) Potential Alpha Energy of short-living radon decay products in air collected on filters Range: (0,02 – 4000) μJ Thermoluminescency (TLD) Procedura SCR/ZLGIG/3-001 edycja 4 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/3-001 4th edition of 25 August 2023 Wyroby inne - Dawkomierze w polu promieniowania Filtr powietrza Other products - Dosimeters in radiation field Air filter Energia potencjalna α krotkozyciowych produktow rozpadu radonu zgromadzonych na filtrze Zakres: (0,02 – 4000) μJ Metoda dozymetrii termoluminescencyjnej (TLD) Potential Alpha Energy of short-living radon decay products in air collected on filters Range: (0,02 – 4000) μJ Thermoluminescency (TLD) Procedura SCR/ZLGIG/3-001 edycja 4 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/3-001 4th edition of 25 August 2023","categories":["other"],"row_index":34,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Other products - Dosimeters in radiation field Air filter Potential Alpha Energy of short-living radon decay products in air collected on filters Range: (0,02 – 4000) μJ Thermoluminescency (TLD) Procedura SCR/ZLGIG/3-001 edycja 4 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/3-001 4th edition of 25 August 2023","search_zh":"其他制品 － 辐射场中的剂量计 空气过滤器 Other products - Dosimeters in radiation field Air filter Procedura SCR/ZLGIG/3-001 edycja 4 z dnia 25.08.2023 r. Procedure SCR/ZLGIG/3-001 4th edition of 25 August 2023","test_object_zh":"其他制品 － 辐射场中的剂量计 空气过滤器 Other products - Dosimeters in radiation field Air filter"},{"_id":"6a5a55ef9af9f73f38250abf","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Wyroby inne - Dawkomierze w polu promieniowania Filtr powietrza Other products - Dosimeters in radiation field Air filter","test_object_en":"Other products - Dosimeters in radiation field Air filter","methodology":"Stężenie energii potencjalnej α krótkożyciowych produktów rozpadu radonu w powietrzu Zakres: (0,01 – 2000) μJ/m3 Metoda dozymetrii termoluminescencyjnej (TLD) Potential Alpha Energy Concentration of short-living radon decay products in air collected on filters Range: (0,01 – 2000) μJ/m3 Thermoluminescency (TLD)","methodology_en":"Potential Alpha Energy Concentration of short-living radon decay products in air collected on filters Range: (0,01 – 2000) μJ/m3 Thermoluminescency (TLD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie energii potencjalnej α krótkożyciowych produktów rozpadu radonu w powietrzu Zakres: (0,01 – 2000) μJ/m3 Metoda dozymetrii termoluminescencyjnej (TLD) Potential Alpha Energy Concentration of short-living radon decay products in air collected on filters Range: (0,01 – 2000) μJ/m3 Thermoluminescency (TLD)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby inne - Dawkomierze w polu promieniowania Filtr powietrza Other products - Dosimeters in radiation field Air filter Stężenie energii potencjalnej α krótkożyciowych produktów rozpadu radonu w powietrzu Zakres: (0,01 – 2000) μJ/m3 Metoda dozymetrii termoluminescencyjnej (TLD) Potential Alpha Energy Concentration of short-living radon decay products in air collected on filters Range: (0,01 – 2000) μJ/m3 Thermoluminescency (TLD) Wyroby inne - Dawkomierze w polu promieniowania Filtr powietrza Other products - Dosimeters in radiation field Air filter Stezenie energii potencjalnej α krotkozyciowych produktow rozpadu radonu w powietrzu Zakres: (0,01 – 2000) μJ/m3 Metoda dozymetrii termoluminescencyjnej (TLD) Potential Alpha Energy Concentration of short-living radon decay products in air collected on filters Range: (0,01 – 2000) μJ/m3 Thermoluminescency (TLD)","categories":["other"],"row_index":35,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Other products - Dosimeters in radiation field Air filter Potential Alpha Energy Concentration of short-living radon decay products in air collected on filters Range: (0,01 – 2000) μJ/m3 Thermoluminescency (TLD)","search_zh":"其他制品 － 辐射场中的剂量计 空气过滤器 Other products - Dosimeters in radiation field Air filter","test_object_zh":"其他制品 － 辐射场中的剂量计 空气过滤器 Other products - Dosimeters in radiation field Air filter"},{"_id":"6a5a55ef9af9f73f38250ac0","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Druty Wires","test_object_en":"Wires","methodology":"Średnica drutu Metoda pomiaru bezpośredniego Wire diameter Direct measurement method","methodology_en":"Wire diameter Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Średnica drutu Metoda pomiaru bezpośredniego Wire diameter Direct measurement method","reference":"PN-ISO 3154:1997 p. 5.2.2","norm_bases":["PN-ISO 3154:1997 p. 5.2.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Druty Wires Średnica drutu Metoda pomiaru bezpośredniego Wire diameter Direct measurement method PN-ISO 3154:1997 p. 5.2.2 Druty Wires Srednica drutu Metoda pomiaru bezposredniego Wire diameter Direct measurement method PN-ISO 3154:1997 p. 5.2.2","categories":["other"],"row_index":36,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wires Wire diameter Direct measurement method PN-ISO 3154:1997 p. 5.2.2","search_zh":"钢丝 Wires PN-ISO 3154:1997 p. 5.2.2","test_object_zh":"钢丝 Wires"},{"_id":"6a5a55ef9af9f73f38250ac1","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Druty Wires","test_object_en":"Wires","methodology":"Rzeczywista siła zrywająca Zakres: siła (0 – 100) kN Metoda obciążania siłą Actual breaking force Range: force (0 – 100) kN Force method","methodology_en":"Actual breaking force Range: force (0 – 100) kN Force method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Rzeczywista siła zrywająca Zakres: siła (0 – 100) kN Metoda obciążania siłą Actual breaking force Range: force (0 – 100) kN Force method","reference":"PN-ISO 3154:1997 p. 5.2.3","norm_bases":["PN-ISO 3154:1997 p. 5.2.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Druty Wires Rzeczywista siła zrywająca Zakres: siła (0 – 100) kN Metoda obciążania siłą Actual breaking force Range: force (0 – 100) kN Force method PN-ISO 3154:1997 p. 5.2.3 Druty Wires Rzeczywista sila zrywajaca Zakres: sila (0 – 100) kN Metoda obciazania sila Actual breaking force Range: force (0 – 100) kN Force method PN-ISO 3154:1997 p. 5.2.3","categories":["other"],"row_index":37,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wires Actual breaking force Range: force (0 – 100) kN Force method PN-ISO 3154:1997 p. 5.2.3","search_zh":"钢丝 Wires PN-ISO 3154:1997 p. 5.2.3","test_object_zh":"钢丝 Wires"},{"_id":"6a5a55ef9af9f73f38250ac2","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Druty Wires","test_object_en":"Wires","methodology":"Odporność na deformację plastyczną Zakres: średnica (1 – 3,5) mm Metoda jednokierunkowego skręcania Plastic deformation resistance Range: diameter (1 – 3,5) mm Torsion test in one direction","methodology_en":"Plastic deformation resistance Range: diameter (1 – 3,5) mm Torsion test in one direction","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na deformację plastyczną Zakres: średnica (1 – 3,5) mm Metoda jednokierunkowego skręcania Plastic deformation resistance Range: diameter (1 – 3,5) mm Torsion test in one direction","reference":"PN-ISO 7800:1996","norm_bases":["PN-ISO 7800:1996"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Druty Wires Odporność na deformację plastyczną Zakres: średnica (1 – 3,5) mm Metoda jednokierunkowego skręcania Plastic deformation resistance Range: diameter (1 – 3,5) mm Torsion test in one direction PN-ISO 7800:1996 Druty Wires Odpornosc na deformacje plastyczna Zakres: srednica (1 – 3,5) mm Metoda jednokierunkowego skrecania Plastic deformation resistance Range: diameter (1 – 3,5) mm Torsion test in one direction PN-ISO 7800:1996","categories":["materials"],"row_index":38,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wires Plastic deformation resistance Range: diameter (1 – 3,5) mm Torsion test in one direction PN-ISO 7800:1996","search_zh":"钢丝 Wires PN-ISO 7800:1996","test_object_zh":"钢丝 Wires"},{"_id":"6a5a55ef9af9f73f38250ac3","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Druty Wires","test_object_en":"Wires","methodology":"Odporność na odkształcenia plastyczne Zakres: średnica (0,7 – 4,0) mm Próba przeginania dwukierunkowego Resistance to plastic strain Range: diameter (0,7 – 4,0) mm Reverse bend test","methodology_en":"Resistance to plastic strain Range: diameter (0,7 – 4,0) mm Reverse bend test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na odkształcenia plastyczne Zakres: średnica (0,7 – 4,0) mm Próba przeginania dwukierunkowego Resistance to plastic strain Range: diameter (0,7 – 4,0) mm Reverse bend test","reference":"PN-ISO 7801:1996","norm_bases":["PN-ISO 7801:1996"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Druty Wires Odporność na odkształcenia plastyczne Zakres: średnica (0,7 – 4,0) mm Próba przeginania dwukierunkowego Resistance to plastic strain Range: diameter (0,7 – 4,0) mm Reverse bend test PN-ISO 7801:1996 Druty Wires Odpornosc na odksztalcenia plastyczne Zakres: srednica (0,7 – 4,0) mm Proba przeginania dwukierunkowego Resistance to plastic strain Range: diameter (0,7 – 4,0) mm Reverse bend test PN-ISO 7801:1996","categories":["materials"],"row_index":39,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wires Resistance to plastic strain Range: diameter (0,7 – 4,0) mm Reverse bend test PN-ISO 7801:1996","search_zh":"钢丝 Wires PN-ISO 7801:1996","test_object_zh":"钢丝 Wires"},{"_id":"6a5a55ef9af9f73f38250ac4","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Liny stalowe Steel ropes","test_object_en":"Steel ropes","methodology":"Średnica liny Zakres: (0 – 300) mm Metoda pomiaru bezpośredniego Rope diameter Range: (0 – 300) mm Direct measurement method","methodology_en":"Rope diameter Range: (0 – 300) mm Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Średnica liny Zakres: (0 – 300) mm Metoda pomiaru bezpośredniego Rope diameter Range: (0 – 300) mm Direct measurement method","reference":"PN-ISO 3154:1997 p. 5.1.1","norm_bases":["PN-ISO 3154:1997 p. 5.1.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Liny stalowe Steel ropes Średnica liny Zakres: (0 – 300) mm Metoda pomiaru bezpośredniego Rope diameter Range: (0 – 300) mm Direct measurement method PN-ISO 3154:1997 p. 5.1.1 Liny stalowe Steel ropes Srednica liny Zakres: (0 – 300) mm Metoda pomiaru bezposredniego Rope diameter Range: (0 – 300) mm Direct measurement method PN-ISO 3154:1997 p. 5.1.1","categories":["materials"],"row_index":40,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Steel ropes Rope diameter Range: (0 – 300) mm Direct measurement method PN-ISO 3154:1997 p. 5.1.1","search_zh":"钢丝绳 Steel ropes PN-ISO 3154:1997 p. 5.1.1","test_object_zh":"钢丝绳 Steel ropes"},{"_id":"6a5a55ef9af9f73f38250ac5","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Liny stalowe Steel ropes","test_object_en":"Steel ropes","methodology":"Rzeczywista siła zrywająca Zakres: siła (0 – 5000) kN Metoda obciążania siłą Actual breaking force Range: force (0 – 500) kN Force method","methodology_en":"Actual breaking force Range: force (0 – 500) kN Force method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Rzeczywista siła zrywająca Zakres: siła (0 – 5000) kN Metoda obciążania siłą Actual breaking force Range: force (0 – 500) kN Force method","reference":"PN-ISO 3108:1996 PN-ISO 3154:1997 p. 5.1.4.2","norm_bases":["PN-ISO 3108:1996 PN-ISO 3154:1997 p. 5.1.4.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Liny stalowe Steel ropes Rzeczywista siła zrywająca Zakres: siła (0 – 5000) kN Metoda obciążania siłą Actual breaking force Range: force (0 – 500) kN Force method PN-ISO 3108:1996 PN-ISO 3154:1997 p. 5.1.4.2 Liny stalowe Steel ropes Rzeczywista sila zrywajaca Zakres: sila (0 – 5000) kN Metoda obciazania sila Actual breaking force Range: force (0 – 500) kN Force method PN-ISO 3108:1996 PN-ISO 3154:1997 p. 5.1.4.2","categories":["materials"],"row_index":41,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Steel ropes Actual breaking force Range: force (0 – 500) kN Force method PN-ISO 3108:1996 PN-ISO 3154:1997 p. 5.1.4.2","search_zh":"钢丝绳 Steel ropes PN-ISO 3108:1996 PN-ISO 3154:1997 p. 5.1.4.2","test_object_zh":"钢丝绳 Steel ropes"},{"_id":"6a5a55ef9af9f73f38250ac6","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Liny stalowe Steel ropes","test_object_en":"Steel ropes","methodology":"Wydłużenie Zakres: (0 – 2000) mm Metoda pomiaru bezpośredniego Elongation Range: (0 – 2000) mm Direct measurement method","methodology_en":"Elongation Range: (0 – 2000) mm Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wydłużenie Zakres: (0 – 2000) mm Metoda pomiaru bezpośredniego Elongation Range: (0 – 2000) mm Direct measurement method","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Liny stalowe Steel ropes Wydłużenie Zakres: (0 – 2000) mm Metoda pomiaru bezpośredniego Elongation Range: (0 – 2000) mm Direct measurement method Liny stalowe Steel ropes Wydluzenie Zakres: (0 – 2000) mm Metoda pomiaru bezposredniego Elongation Range: (0 – 2000) mm Direct measurement method","categories":["materials"],"row_index":42,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Steel ropes Elongation Range: (0 – 2000) mm Direct measurement method","methodology_zh":"伸长 范围：(0 – 2000) mm 直接测量法 Elongation Range: (0 – 2000) mm Direct measurement method","search_zh":"钢丝绳 Steel ropes 伸长 范围：(0 – 2000) mm 直接测量法 Elongation Range: (0 – 2000) mm Direct measurement method","test_object_zh":"钢丝绳 Steel ropes"},{"_id":"6a5a55ef9af9f73f38250ac7","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Liny stalowe Steel ropes","test_object_en":"Steel ropes","methodology":"Nieciągłości i zmiana przekroju metalicznego liny Zakres średnic lin do 60 mm Prędkość: (0,1 – 3,0) m/s Metoda magnetyczna lin MTR Discontinuities and change of rope metallic cross-section Range of rope diameters up to 60 mm Velocity: (0,1 – 3,0) meters per second Magnetic method for ropes MTR","methodology_en":"Discontinuities and change of rope metallic cross-section Range of rope diameters up to 60 mm Velocity: (0,1 – 3,0) m/s Magnetic method for ropes MTR Discontinuities and change of rope metallic cross-section Range of rope diameters up to 60 mm Velocity: (0,1 – 3,0) meters per second Magnetic method for ropes MTR","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nieciągłości i zmiana przekroju metalicznego liny Zakres średnic lin do 60 mm Prędkość: (0,1 – 3,0) m/s Metoda magnetyczna lin MTR Discontinuities and change of rope metallic cross-section Range of rope diameters up to 60 mm Velocity: (0,1 – 3,0) meters per second Magnetic method for ropes MTR","reference":"PN-92/G-46603 PN-EN 12927:2019-07","norm_bases":["PN-92/G-46603 PN-EN 12927:2019-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Liny stalowe Steel ropes Nieciągłości i zmiana przekroju metalicznego liny Zakres średnic lin do 60 mm Prędkość: (0,1 – 3,0) m/s Metoda magnetyczna lin MTR Discontinuities and change of rope metallic cross-section Range of rope diameters up to 60 mm Velocity: (0,1 – 3,0) meters per second Magnetic method for ropes MTR PN-92/G-46603 PN-EN 12927:2019-07 Liny stalowe Steel ropes Nieciaglosci i zmiana przekroju metalicznego liny Zakres srednic lin do 60 mm Predkosc: (0,1 – 3,0) m/s Metoda magnetyczna lin MTR Discontinuities and change of rope metallic cross-section Range of rope diameters up to 60 mm Velocity: (0,1 – 3,0) meters per second Magnetic method for ropes MTR PN-92/G-46603 PN-EN 12927:2019-07","categories":["materials"],"row_index":43,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Steel ropes Discontinuities and change of rope metallic cross-section Range of rope diameters up to 60 mm Velocity: (0,1 – 3,0) m/s Magnetic method for ropes MTR Discontinuities and change of rope metallic cross-section Range of rope diameters up to 60 mm Velocity: (0,1 – 3,0) meters per second Magnetic method for ropes MTR PN-92/G-46603 PN-EN 12927:2019-07","search_zh":"钢丝绳 Steel ropes PN-92/G-46603 PN-EN 12927:2019-07","test_object_zh":"钢丝绳 Steel ropes"},{"_id":"6a5a55ef9af9f73f38250ac8","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Łańcuchy ogniwowe górnicze Link mining chains","test_object_en":"Link mining chains","methodology":"Obciążenie rozrywające Zakres: siła (0 – 5000) kN Metoda obciążania siłą Breaking load Range: force (0 – 5000) kN Force method","methodology_en":"Breaking load Range: force (0 – 5000) kN Force loading method Breaking load Range: force (0 – 5000) kN Force method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Obciążenie rozrywające Zakres: siła (0 – 5000) kN Metoda obciążania siłą Breaking load Range: force (0 – 5000) kN Force method","reference":"PN-G-46701:1997/Az1:2001 p. 3.4.6","norm_bases":["PN-G-46701:1997/Az1:2001 p. 3.4.6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łańcuchy ogniwowe górnicze Link mining chains Obciążenie rozrywające Zakres: siła (0 – 5000) kN Metoda obciążania siłą Breaking load Range: force (0 – 5000) kN Force method PN-G-46701:1997/Az1:2001 p. 3.4.6 Lancuchy ogniwowe gornicze Link mining chains Obciazenie rozrywajace Zakres: sila (0 – 5000) kN Metoda obciazania sila Breaking load Range: force (0 – 5000) kN Force method PN-G-46701:1997/Az1:2001 p. 3.4.6","categories":["other"],"row_index":44,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Link mining chains Breaking load Range: force (0 – 5000) kN Force loading method Breaking load Range: force (0 – 5000) kN Force method PN-G-46701:1997/Az1:2001 p. 3.4.6","search_zh":"矿用圆环链 Link mining chains PN-G-46701:1997/Az1:2001 p. 3.4.6","test_object_zh":"矿用圆环链 Link mining chains"},{"_id":"6a5a55ef9af9f73f38250ac9","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Łańcuchy ogniwowe górnicze Link mining chains","test_object_en":"Link mining chains","methodology":"Wydłużenie Zakres: (0 – 2000) mm Metoda pomiaru bezpośredniego Elongation Range: (0 – 2000) mm Direct measurement method","methodology_en":"Elongation Range: (0 – 2000) mm Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wydłużenie Zakres: (0 – 2000) mm Metoda pomiaru bezpośredniego Elongation Range: (0 – 2000) mm Direct measurement method","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łańcuchy ogniwowe górnicze Link mining chains Wydłużenie Zakres: (0 – 2000) mm Metoda pomiaru bezpośredniego Elongation Range: (0 – 2000) mm Direct measurement method Lancuchy ogniwowe gornicze Link mining chains Wydluzenie Zakres: (0 – 2000) mm Metoda pomiaru bezposredniego Elongation Range: (0 – 2000) mm Direct measurement method","categories":["other"],"row_index":45,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Link mining chains Elongation Range: (0 – 2000) mm Direct measurement method","methodology_zh":"伸长 范围：(0 – 2000) mm 直接测量法 Elongation Range: (0 – 2000) mm Direct measurement method","search_zh":"矿用圆环链 Link mining chains 伸长 范围：(0 – 2000) mm 直接测量法 Elongation Range: (0 – 2000) mm Direct measurement method","test_object_zh":"矿用圆环链 Link mining chains"},{"_id":"6a5a55ef9af9f73f38250aca","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Elementy konstrukcyjne Construction elements","test_object_en":"Construction elements","methodology":"Obciążenie rozrywające Zakres: siła (0 – 5000) kN Metoda obciążania siłą Breaking load Range: force (0 – 5000) kN Force method","methodology_en":"Breaking load Range: force (0 – 5000) kN Force loading method Breaking load Range: force (0 – 5000) kN Force method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Obciążenie rozrywające Zakres: siła (0 – 5000) kN Metoda obciążania siłą Breaking load Range: force (0 – 5000) kN Force method","reference":"PN-G-46701:1997/Az1:2001 p. 3.4.6 DIN 22252:2001 p. 6.4.2 | PN-G-46705:1997 p. 3.7.6","norm_bases":["PN-G-46701:1997/Az1:2001 p. 3.4.6 DIN 22252:2001 p. 6.4.2","PN-G-46705:1997 p. 3.7.6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy konstrukcyjne Construction elements Obciążenie rozrywające Zakres: siła (0 – 5000) kN Metoda obciążania siłą Breaking load Range: force (0 – 5000) kN Force method PN-G-46701:1997/Az1:2001 p. 3.4.6 DIN 22252:2001 p. 6.4.2 | PN-G-46705:1997 p. 3.7.6 Elementy konstrukcyjne Construction elements Obciazenie rozrywajace Zakres: sila (0 – 5000) kN Metoda obciazania sila Breaking load Range: force (0 – 5000) kN Force method PN-G-46701:1997/Az1:2001 p. 3.4.6 DIN 22252:2001 p. 6.4.2 | PN-G-46705:1997 p. 3.7.6","categories":["construction"],"row_index":46,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Construction elements Breaking load Range: force (0 – 5000) kN Force loading method Breaking load Range: force (0 – 5000) kN Force method PN-G-46701:1997/Az1:2001 p. 3.4.6 DIN 22252:2001 p. 6.4.2 | PN-G-46705:1997 p. 3.7.6","search_zh":"结构构件 Construction elements PN-G-46701:1997/Az1:2001 p. 3.4.6 DIN 22252:2001 p. 6.4.2 | PN-G-46705:1997 p. 3.7.6","test_object_zh":"结构构件 Construction elements"},{"_id":"6a5a55ef9af9f73f38250acb","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Elementy konstrukcyjne Construction elements","test_object_en":"Construction elements","methodology":"Wydłużenie Zakres: (0 – 2000) mm Metoda pomiaru bezpośredniego Elongation Range: (0 – 2000) mm Direct measurement method","methodology_en":"Elongation Range: (0 – 2000) mm Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wydłużenie Zakres: (0 – 2000) mm Metoda pomiaru bezpośredniego Elongation Range: (0 – 2000) mm Direct measurement method","reference":"PN-G-46701:1997/Az1:2001 p. 3.4.6 DIN 22252:2001 p. 6.4.2.3","norm_bases":["PN-G-46701:1997/Az1:2001 p. 3.4.6 DIN 22252:2001 p. 6.4.2.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy konstrukcyjne Construction elements Wydłużenie Zakres: (0 – 2000) mm Metoda pomiaru bezpośredniego Elongation Range: (0 – 2000) mm Direct measurement method PN-G-46701:1997/Az1:2001 p. 3.4.6 DIN 22252:2001 p. 6.4.2.3 Elementy konstrukcyjne Construction elements Wydluzenie Zakres: (0 – 2000) mm Metoda pomiaru bezposredniego Elongation Range: (0 – 2000) mm Direct measurement method PN-G-46701:1997/Az1:2001 p. 3.4.6 DIN 22252:2001 p. 6.4.2.3","categories":["construction"],"row_index":47,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Construction elements Elongation Range: (0 – 2000) mm Direct measurement method PN-G-46701:1997/Az1:2001 p. 3.4.6 DIN 22252:2001 p. 6.4.2.3","methodology_zh":"伸长 范围：(0 – 2000) mm 直接测量法 Elongation Range: (0 – 2000) mm Direct measurement method","search_zh":"结构构件 Construction elements 伸长 范围：(0 – 2000) mm 直接测量法 Elongation Range: (0 – 2000) mm Direct measurement method PN-G-46701:1997/Az1:2001 p. 3.4.6 DIN 22252:2001 p. 6.4.2.3","test_object_zh":"结构构件 Construction elements"},{"_id":"6a5a55ef9af9f73f38250acc","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Elementy konstrukcyjne Construction elements","test_object_en":"Construction elements","methodology":"Siła rozciągająca Zakres: siła (0 – 5000) kN Próba rozciągania Tensile force Range: force (0 – 5000) kN Tensile test","methodology_en":"Tensile force Range: force (0 – 5000) kN Tensile test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła rozciągająca Zakres: siła (0 – 5000) kN Próba rozciągania Tensile force Range: force (0 – 5000) kN Tensile test","reference":"PN-EN 61284:2002 p. 11.5.1, 11.6.1, 11.6.2.1, 11.6.2.2, 11.7","norm_bases":["PN-EN 61284:2002 p. 11.5.1, 11.6.1, 11.6.2.1, 11.6.2.2, 11.7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy konstrukcyjne Construction elements Siła rozciągająca Zakres: siła (0 – 5000) kN Próba rozciągania Tensile force Range: force (0 – 5000) kN Tensile test PN-EN 61284:2002 p. 11.5.1, 11.6.1, 11.6.2.1, 11.6.2.2, 11.7 Elementy konstrukcyjne Construction elements Sila rozciagajaca Zakres: sila (0 – 5000) kN Proba rozciagania Tensile force Range: force (0 – 5000) kN Tensile test PN-EN 61284:2002 p. 11.5.1, 11.6.1, 11.6.2.1, 11.6.2.2, 11.7","categories":["construction"],"row_index":48,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Construction elements Tensile force Range: force (0 – 5000) kN Tensile test PN-EN 61284:2002 p. 11.5.1, 11.6.1, 11.6.2.1, 11.6.2.2, 11.7","search_zh":"结构构件 Construction elements PN-EN 61284:2002 p. 11.5.1, 11.6.1, 11.6.2.1, 11.6.2.2, 11.7","test_object_zh":"结构构件 Construction elements"},{"_id":"6a5a55ef9af9f73f38250acd","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Elementy konstrukcyjne Construction elements","test_object_en":"Construction elements","methodology":"Obciążenie odkształcające trwale i obciążenie niszczące Zakres: siła (0 – 5000) kN Metoda obciążania siłą Mechanical damage and failure load Range: force (0 – 5000) kN Force method","methodology_en":"Permanent deformation load and failure load Range: force (0 – 5000) kN Force loading method Mechanical damage and failure load Range: force (0 – 5000) kN Force method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Obciążenie odkształcające trwale i obciążenie niszczące Zakres: siła (0 – 5000) kN Metoda obciążania siłą Mechanical damage and failure load Range: force (0 – 5000) kN Force method","reference":"PN-EN 61284:2002 p. 11.3.1","norm_bases":["PN-EN 61284:2002 p. 11.3.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy konstrukcyjne Construction elements Obciążenie odkształcające trwale i obciążenie niszczące Zakres: siła (0 – 5000) kN Metoda obciążania siłą Mechanical damage and failure load Range: force (0 – 5000) kN Force method PN-EN 61284:2002 p. 11.3.1 Elementy konstrukcyjne Construction elements Obciazenie odksztalcajace trwale i obciazenie niszczace Zakres: sila (0 – 5000) kN Metoda obciazania sila Mechanical damage and failure load Range: force (0 – 5000) kN Force method PN-EN 61284:2002 p. 11.3.1","categories":["construction"],"row_index":49,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Construction elements Permanent deformation load and failure load Range: force (0 – 5000) kN Force loading method Mechanical damage and failure load Range: force (0 – 5000) kN Force method PN-EN 61284:2002 p. 11.3.1","search_zh":"结构构件 Construction elements PN-EN 61284:2002 p. 11.3.1","test_object_zh":"结构构件 Construction elements"},{"_id":"6a5a55ef9af9f73f38250ace","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Elementy konstrukcyjne Construction elements","test_object_en":"Construction elements","methodology":"Siła rozciągająca Zakres: siła (0 – 5000) kN Próba wyślizgu Tensile force Range: force (0 – 5000) kN Slippage test","methodology_en":"Tensile force Range: force (0 – 5000) kN Slippage test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła rozciągająca Zakres: siła (0 – 5000) kN Próba wyślizgu Tensile force Range: force (0 – 5000) kN Slippage test","reference":"PN-EN 61284:2002 p. 11.4.2","norm_bases":["PN-EN 61284:2002 p. 11.4.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy konstrukcyjne Construction elements Siła rozciągająca Zakres: siła (0 – 5000) kN Próba wyślizgu Tensile force Range: force (0 – 5000) kN Slippage test PN-EN 61284:2002 p. 11.4.2 Elementy konstrukcyjne Construction elements Sila rozciagajaca Zakres: sila (0 – 5000) kN Proba wyslizgu Tensile force Range: force (0 – 5000) kN Slippage test PN-EN 61284:2002 p. 11.4.2","categories":["construction"],"row_index":50,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Construction elements Tensile force Range: force (0 – 5000) kN Slippage test PN-EN 61284:2002 p. 11.4.2","search_zh":"结构构件 Construction elements PN-EN 61284:2002 p. 11.4.2","test_object_zh":"结构构件 Construction elements"},{"_id":"6a5a55ef9af9f73f38250acf","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Elementy konstrukcyjne Construction elements","test_object_en":"Construction elements","methodology":"Wymiary i materiał osprzętu Zakres: (0 – 2000) mm Metoda pomiaru bezpośredniego, Kontrola dokumentacji materiałowej Dimensions and material of fittings Range: (0 – 2000) mm Direct measurement method Inspection of material documents","methodology_en":"Dimensions and material of fittings Range: (0 – 2000) mm Direct measurement method Inspection of material documents","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary i materiał osprzętu Zakres: (0 – 2000) mm Metoda pomiaru bezpośredniego, Kontrola dokumentacji materiałowej Dimensions and material of fittings Range: (0 – 2000) mm Direct measurement method Inspection of material documents","reference":"PN-EN 61284:2002 p. 8","norm_bases":["PN-EN 61284:2002 p. 8"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy konstrukcyjne Construction elements Wymiary i materiał osprzętu Zakres: (0 – 2000) mm Metoda pomiaru bezpośredniego, Kontrola dokumentacji materiałowej Dimensions and material of fittings Range: (0 – 2000) mm Direct measurement method Inspection of material documents PN-EN 61284:2002 p. 8 Elementy konstrukcyjne Construction elements Wymiary i material osprzetu Zakres: (0 – 2000) mm Metoda pomiaru bezposredniego, Kontrola dokumentacji materialowej Dimensions and material of fittings Range: (0 – 2000) mm Direct measurement method Inspection of material documents PN-EN 61284:2002 p. 8","categories":["materials","construction"],"row_index":51,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Construction elements Dimensions and material of fittings Range: (0 – 2000) mm Direct measurement method Inspection of material documents PN-EN 61284:2002 p. 8","search_zh":"结构构件 Construction elements PN-EN 61284:2002 p. 8","test_object_zh":"结构构件 Construction elements"},{"_id":"6a5a55ef9af9f73f38250ad0","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Elementy konstrukcyjne Construction elements","test_object_en":"Construction elements","methodology":"Właściwości elektryczne połączeń prądowych Zakres: (0 – 1000) mΩ, (0 – 200)ºC Próby cyklicznym nagrzewaniem Electric properties of power supply connections Range: (0 – 1000) mΩ, (0 – 200)ºC Thermal cycle testing","methodology_en":"Electric properties of power supply connections Range: (0 – 1000) mΩ, (0 – 200)ºC Thermal cycle testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Właściwości elektryczne połączeń prądowych Zakres: (0 – 1000) mΩ, (0 – 200)ºC Próby cyklicznym nagrzewaniem Electric properties of power supply connections Range: (0 – 1000) mΩ, (0 – 200)ºC Thermal cycle testing","reference":"PN-EN 61284:2002 p. 13","norm_bases":["PN-EN 61284:2002 p. 13"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy konstrukcyjne Construction elements Właściwości elektryczne połączeń prądowych Zakres: (0 – 1000) mΩ, (0 – 200)ºC Próby cyklicznym nagrzewaniem Electric properties of power supply connections Range: (0 – 1000) mΩ, (0 – 200)ºC Thermal cycle testing PN-EN 61284:2002 p. 13 Elementy konstrukcyjne Construction elements Wlasciwosci elektryczne polaczen pradowych Zakres: (0 – 1000) mΩ, (0 – 200)ºC Proby cyklicznym nagrzewaniem Electric properties of power supply connections Range: (0 – 1000) mΩ, (0 – 200)ºC Thermal cycle testing PN-EN 61284:2002 p. 13","categories":["construction"],"row_index":52,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Construction elements Electric properties of power supply connections Range: (0 – 1000) mΩ, (0 – 200)ºC Thermal cycle testing PN-EN 61284:2002 p. 13","search_zh":"结构构件 Construction elements PN-EN 61284:2002 p. 13","test_object_zh":"结构构件 Construction elements"},{"_id":"6a5a55ef9af9f73f38250ad1","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Łańcuchy ogniwowe górnicze Link mining chains","test_object_en":"Link mining chains","methodology":"Trwałość zmęczeniowa Zakres: - siła (20 – 1000) kN - częstotliwość do 14 Hz Próba zmęczeniowa Fatigue resistance Range: - force (20 – 1000) kN - frequency up to 14 Hz Fatigue test","methodology_en":"Fatigue resistance Range: - force (20 – 1000) kN - frequency up to 14 Hz Fatigue test Fatigue resistance Range: - force (20 – 1000) kN - frequency up to 14 Hz Fatigue test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość zmęczeniowa Zakres: - siła (20 – 1000) kN - częstotliwość do 14 Hz Próba zmęczeniowa Fatigue resistance Range: - force (20 – 1000) kN - frequency up to 14 Hz Fatigue test","reference":"PN-G-46701:1997/Az1:2001 p. 3.4.9 DIN 22252:2001 p. 7.2","norm_bases":["PN-G-46701:1997/Az1:2001 p. 3.4.9 DIN 22252:2001 p. 7.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łańcuchy ogniwowe górnicze Link mining chains Trwałość zmęczeniowa Zakres: - siła (20 – 1000) kN - częstotliwość do 14 Hz Próba zmęczeniowa Fatigue resistance Range: - force (20 – 1000) kN - frequency up to 14 Hz Fatigue test PN-G-46701:1997/Az1:2001 p. 3.4.9 DIN 22252:2001 p. 7.2 Lancuchy ogniwowe gornicze Link mining chains Trwalosc zmeczeniowa Zakres: - sila (20 – 1000) kN - czestotliwosc do 14 Hz Proba zmeczeniowa Fatigue resistance Range: - force (20 – 1000) kN - frequency up to 14 Hz Fatigue test PN-G-46701:1997/Az1:2001 p. 3.4.9 DIN 22252:2001 p. 7.2","categories":["other"],"row_index":53,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Link mining chains Fatigue resistance Range: - force (20 – 1000) kN - frequency up to 14 Hz Fatigue test Fatigue resistance Range: - force (20 – 1000) kN - frequency up to 14 Hz Fatigue test PN-G-46701:1997/Az1:2001 p. 3.4.9 DIN 22252:2001 p. 7.2","search_zh":"矿用圆环链 Link mining chains PN-G-46701:1997/Az1:2001 p. 3.4.9 DIN 22252:2001 p. 7.2","test_object_zh":"矿用圆环链 Link mining chains"},{"_id":"6a5a55ef9af9f73f38250ad2","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Łańcuchy ogniwowe górnicze Link mining chains","test_object_en":"Link mining chains","methodology":"Wytrzymałość na zginanie Zakres: siła (0 – 1000) kN Metoda obciążania siłą Bending resistance Range: force (0 – 1000) kN Force method","methodology_en":"Bending resistance Range: force (0 – 1000) kN Force method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na zginanie Zakres: siła (0 – 1000) kN Metoda obciążania siłą Bending resistance Range: force (0 – 1000) kN Force method","reference":"PN-G-46701:1997/Az1:2001 p. 3.4.7 DIN 22252:2001 p. 6.5","norm_bases":["PN-G-46701:1997/Az1:2001 p. 3.4.7 DIN 22252:2001 p. 6.5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łańcuchy ogniwowe górnicze Link mining chains Wytrzymałość na zginanie Zakres: siła (0 – 1000) kN Metoda obciążania siłą Bending resistance Range: force (0 – 1000) kN Force method PN-G-46701:1997/Az1:2001 p. 3.4.7 DIN 22252:2001 p. 6.5 Lancuchy ogniwowe gornicze Link mining chains Wytrzymalosc na zginanie Zakres: sila (0 – 1000) kN Metoda obciazania sila Bending resistance Range: force (0 – 1000) kN Force method PN-G-46701:1997/Az1:2001 p. 3.4.7 DIN 22252:2001 p. 6.5","categories":["other"],"row_index":54,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Link mining chains Bending resistance Range: force (0 – 1000) kN Force method PN-G-46701:1997/Az1:2001 p. 3.4.7 DIN 22252:2001 p. 6.5","search_zh":"矿用圆环链 Link mining chains PN-G-46701:1997/Az1:2001 p. 3.4.7 DIN 22252:2001 p. 6.5","test_object_zh":"矿用圆环链 Link mining chains"},{"_id":"6a5a55ef9af9f73f38250ad3","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Uniwersalne ogniwa złączne Universal connecting links","test_object_en":"Universal connecting links","methodology":"Trwałość zmęczeniowa Zakres: - siła (20 – 1000) kN - częstotliwość do 14 Hz Próba zmęczeniowa Fatigue resistance Range: - force (20 – 1000) kN - frequency up to 14 Hz Fatigue test","methodology_en":"Fatigue resistance Range: - force (20 – 1000) kN - frequency up to 14 Hz Fatigue test Fatigue resistance Range: - force (20 – 1000) kN - frequency up to 14 Hz Fatigue test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość zmęczeniowa Zakres: - siła (20 – 1000) kN - częstotliwość do 14 Hz Próba zmęczeniowa Fatigue resistance Range: - force (20 – 1000) kN - frequency up to 14 Hz Fatigue test","reference":"PN-G-46705:1997 p. 3.7.7","norm_bases":["PN-G-46705:1997 p. 3.7.7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Uniwersalne ogniwa złączne Universal connecting links Trwałość zmęczeniowa Zakres: - siła (20 – 1000) kN - częstotliwość do 14 Hz Próba zmęczeniowa Fatigue resistance Range: - force (20 – 1000) kN - frequency up to 14 Hz Fatigue test PN-G-46705:1997 p. 3.7.7 Uniwersalne ogniwa zlaczne Universal connecting links Trwalosc zmeczeniowa Zakres: - sila (20 – 1000) kN - czestotliwosc do 14 Hz Proba zmeczeniowa Fatigue resistance Range: - force (20 – 1000) kN - frequency up to 14 Hz Fatigue test PN-G-46705:1997 p. 3.7.7","categories":["other"],"row_index":55,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Universal connecting links Fatigue resistance Range: - force (20 – 1000) kN - frequency up to 14 Hz Fatigue test Fatigue resistance Range: - force (20 – 1000) kN - frequency up to 14 Hz Fatigue test PN-G-46705:1997 p. 3.7.7"},{"_id":"6a5a55ef9af9f73f38250ad4","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Przewody Conductors","test_object_en":"Conductors","methodology":"Siła rozciągająca Zakres: (0 – 5000) kN Próba rozciągania Tensile force Range: (0 – 5000) kN Tensile test","methodology_en":"Tensile force Range: (0 – 5000) kN Tensile test Tensile force Range: (0 – 5000) kN Tensile test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła rozciągająca Zakres: (0 – 5000) kN Próba rozciągania Tensile force Range: (0 – 5000) kN Tensile test","reference":"PN-IEC 1089:1994 p. 6.5.3 PN-EN 50182:2002 p. 6.4.8 + Zał. C /annex C IEC 62420:2008 p. 6.2.5 + Zał. B /annex B PN-EN 60889:2002 p. 10.1 PN-EN 50189:2002 p. 11.4 PN-EN 60889:2002 p. 6.4.10 + Zał. A/annex B PN-EN 50183:2002 p. 11.3","norm_bases":["PN-IEC 1089:1994 p. 6.5.3 PN-EN 50182:2002 p. 6.4.8 + Zał. C /annex C IEC 62420:2008 p. 6.2.5 + Zał. B /annex B PN-EN 60889:2002 p. 10.1 PN-EN 50189:2002 p. 11.4 PN-EN 60889:2002 p. 6.4.10 + Zał. A/annex B PN-EN 50183:2002 p. 11.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody Conductors Siła rozciągająca Zakres: (0 – 5000) kN Próba rozciągania Tensile force Range: (0 – 5000) kN Tensile test PN-IEC 1089:1994 p. 6.5.3 PN-EN 50182:2002 p. 6.4.8 + Zał. C /annex C IEC 62420:2008 p. 6.2.5 + Zał. B /annex B PN-EN 60889:2002 p. 10.1 PN-EN 50189:2002 p. 11.4 PN-EN 60889:2002 p. 6.4.10 + Zał. A/annex B PN-EN 50183:2002 p. 11.3 Przewody Conductors Sila rozciagajaca Zakres: (0 – 5000) kN Proba rozciagania Tensile force Range: (0 – 5000) kN Tensile test PN-IEC 1089:1994 p. 6.5.3 PN-EN 50182:2002 p. 6.4.8 + Zal. C /annex C IEC 62420:2008 p. 6.2.5 + Zal. B /annex B PN-EN 60889:2002 p. 10.1 PN-EN 50189:2002 p. 11.4 PN-EN 60889:2002 p. 6.4.10 + Zal. A/annex B PN-EN 50183:2002 p. 11.3","categories":["other"],"row_index":56,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Conductors Tensile force Range: (0 – 5000) kN Tensile test Tensile force Range: (0 – 5000) kN Tensile test PN-IEC 1089:1994 p. 6.5.3 PN-EN 50182:2002 p. 6.4.8 + Zał. C /annex C IEC 62420:2008 p. 6.2.5 + Zał. B /annex B PN-EN 60889:2002 p. 10.1 PN-EN 50189:2002 p. 11.4 PN-EN 60889:2002 p. 6.4.10 + Zał. A/annex B PN-EN 50183:2002 p. 11.3","search_zh":"导线 Conductors PN-IEC 1089:1994 p. 6.5.3 PN-EN 50182:2002 p. 6.4.8 + Zał. C /annex C IEC 62420:2008 p. 6.2.5 + Zał. B /annex B PN-EN 60889:2002 p. 10.1 PN-EN 50189:2002 p. 11.4 PN-EN 60889:2002 p. 6.4.10 + Zał. A/annex B PN-EN 50183:2002 p. 11.3","test_object_zh":"导线 Conductors"},{"_id":"6a5a55ef9af9f73f38250ad5","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Przewody Conductors","test_object_en":"Conductors","methodology":"Wydłużenie Zakres: (0 – 2000) mm Metoda pomiaru bezpośredniego Elongation Range: (0 – 2000) mm Direct measurement method","methodology_en":"Elongation Range: (0 – 2000) mm Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wydłużenie Zakres: (0 – 2000) mm Metoda pomiaru bezpośredniego Elongation Range: (0 – 2000) mm Direct measurement method","reference":"PN-EN 50182:2002 p. 6.4.7 IEC 62420:2008 + Zał. B/annex B PN-EN 50183:2002 p. 11.3","norm_bases":["PN-EN 50182:2002 p. 6.4.7 IEC 62420:2008 + Zał. B/annex B PN-EN 50183:2002 p. 11.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody Conductors Wydłużenie Zakres: (0 – 2000) mm Metoda pomiaru bezpośredniego Elongation Range: (0 – 2000) mm Direct measurement method PN-EN 50182:2002 p. 6.4.7 IEC 62420:2008 + Zał. B/annex B PN-EN 50183:2002 p. 11.3 Przewody Conductors Wydluzenie Zakres: (0 – 2000) mm Metoda pomiaru bezposredniego Elongation Range: (0 – 2000) mm Direct measurement method PN-EN 50182:2002 p. 6.4.7 IEC 62420:2008 + Zal. B/annex B PN-EN 50183:2002 p. 11.3","categories":["other"],"row_index":57,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Conductors Elongation Range: (0 – 2000) mm Direct measurement method PN-EN 50182:2002 p. 6.4.7 IEC 62420:2008 + Zał. B/annex B PN-EN 50183:2002 p. 11.3","search_zh":"导线 Conductors 伸长 范围：(0 – 2000) mm 直接测量法 Elongation Range: (0 – 2000) mm Direct measurement method PN-EN 50182:2002 p. 6.4.7 IEC 62420:2008 + Zał. B/annex B PN-EN 50183:2002 p. 11.3","test_object_zh":"导线 Conductors","methodology_zh":"伸长 范围：(0 – 2000) mm 直接测量法 Elongation Range: (0 – 2000) mm Direct measurement method"},{"_id":"6a5a55ef9af9f73f38250ad6","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Przewody Conductors","test_object_en":"Conductors","methodology":"Średnica Zakres: (0 – 300) mm Metoda pomiaru bezpośredniego Diameter Range: (0 – 300) mm Direct measurement method","methodology_en":"Diameter Range: (0 – 300) mm Direct measurement method Diameter Range: (0 – 300) mm Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Średnica Zakres: (0 – 300) mm Metoda pomiaru bezpośredniego Diameter Range: (0 – 300) mm Direct measurement method","reference":"PN-IEC 1089:1994 p. 6.6.2 PN-EN 50182:2002 p. 6.4.2 PN-EN 60889:2002 p. 5 PN-EN 50189:2002 p. 7 PN-EN 50540:2010 p. 6.4.2 PN-EN 50183:2002 p. 11.2","norm_bases":["PN-IEC 1089:1994 p. 6.6.2 PN-EN 50182:2002 p. 6.4.2 PN-EN 60889:2002 p. 5 PN-EN 50189:2002 p. 7 PN-EN 50540:2010 p. 6.4.2 PN-EN 50183:2002 p. 11.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody Conductors Średnica Zakres: (0 – 300) mm Metoda pomiaru bezpośredniego Diameter Range: (0 – 300) mm Direct measurement method PN-IEC 1089:1994 p. 6.6.2 PN-EN 50182:2002 p. 6.4.2 PN-EN 60889:2002 p. 5 PN-EN 50189:2002 p. 7 PN-EN 50540:2010 p. 6.4.2 PN-EN 50183:2002 p. 11.2 Przewody Conductors Srednica Zakres: (0 – 300) mm Metoda pomiaru bezposredniego Diameter Range: (0 – 300) mm Direct measurement method PN-IEC 1089:1994 p. 6.6.2 PN-EN 50182:2002 p. 6.4.2 PN-EN 60889:2002 p. 5 PN-EN 50189:2002 p. 7 PN-EN 50540:2010 p. 6.4.2 PN-EN 50183:2002 p. 11.2","categories":["other"],"row_index":58,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Conductors Diameter Range: (0 – 300) mm Direct measurement method Diameter Range: (0 – 300) mm Direct measurement method PN-IEC 1089:1994 p. 6.6.2 PN-EN 50182:2002 p. 6.4.2 PN-EN 60889:2002 p. 5 PN-EN 50189:2002 p. 7 PN-EN 50540:2010 p. 6.4.2 PN-EN 50183:2002 p. 11.2","search_zh":"导线 Conductors PN-IEC 1089:1994 p. 6.6.2 PN-EN 50182:2002 p. 6.4.2 PN-EN 60889:2002 p. 5 PN-EN 50189:2002 p. 7 PN-EN 50540:2010 p. 6.4.2 PN-EN 50183:2002 p. 11.2","test_object_zh":"导线 Conductors"},{"_id":"6a5a55ef9af9f73f38250ad7","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Przewody Conductors","test_object_en":"Conductors","methodology":"Stosunek skrętu Zakres: (6 – 26) Metoda pomiaru bezpośredniego Lay ratio Range: (6 – 26) Direct measurement method","methodology_en":"Lay ratio Range: (6 – 26) Direct measurement method Lay ratio Range: (6 – 26) Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stosunek skrętu Zakres: (6 – 26) Metoda pomiaru bezpośredniego Lay ratio Range: (6 – 26) Direct measurement method","reference":"PN-IEC 1089:1994 p. 6.6.6 PN-EN 50182:2002 p. 6.4.4 PN-EN 50540:2010 p. 6.4.4 PN-EN 62219:2003 p. 6.6.6 PN-EN 62420:2008 p. 6.3.5","norm_bases":["PN-IEC 1089:1994 p. 6.6.6 PN-EN 50182:2002 p. 6.4.4 PN-EN 50540:2010 p. 6.4.4 PN-EN 62219:2003 p. 6.6.6 PN-EN 62420:2008 p. 6.3.5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody Conductors Stosunek skrętu Zakres: (6 – 26) Metoda pomiaru bezpośredniego Lay ratio Range: (6 – 26) Direct measurement method PN-IEC 1089:1994 p. 6.6.6 PN-EN 50182:2002 p. 6.4.4 PN-EN 50540:2010 p. 6.4.4 PN-EN 62219:2003 p. 6.6.6 PN-EN 62420:2008 p. 6.3.5 Przewody Conductors Stosunek skretu Zakres: (6 – 26) Metoda pomiaru bezposredniego Lay ratio Range: (6 – 26) Direct measurement method PN-IEC 1089:1994 p. 6.6.6 PN-EN 50182:2002 p. 6.4.4 PN-EN 50540:2010 p. 6.4.4 PN-EN 62219:2003 p. 6.6.6 PN-EN 62420:2008 p. 6.3.5","categories":["other"],"row_index":59,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Conductors Lay ratio Range: (6 – 26) Direct measurement method Lay ratio Range: (6 – 26) Direct measurement method PN-IEC 1089:1994 p. 6.6.6 PN-EN 50182:2002 p. 6.4.4 PN-EN 50540:2010 p. 6.4.4 PN-EN 62219:2003 p. 6.6.6 PN-EN 62420:2008 p. 6.3.5","search_zh":"导线 Conductors PN-IEC 1089:1994 p. 6.6.6 PN-EN 50182:2002 p. 6.4.4 PN-EN 50540:2010 p. 6.4.4 PN-EN 62219:2003 p. 6.6.6 PN-EN 62420:2008 p. 6.3.5","test_object_zh":"导线 Conductors"},{"_id":"6a5a55ef9af9f73f38250ad8","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Przewody Conductors","test_object_en":"Conductors","methodology":"Kierunek skrętu Metoda badania wizualnego Lay direction Visual examination method","methodology_en":"Lay direction Visual examination method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Kierunek skrętu Metoda badania wizualnego Lay direction Visual examination method","reference":"PN-IEC 1089:1994 p. 6.6.6 PN-EN 50182:2002 p. 6.4.4 PN-EN 50540:2010 p. 6.4.4 PN-EN 62219:2003 p. 6.6.6 PN-EN 62420:2008 p. 6.3.5","norm_bases":["PN-IEC 1089:1994 p. 6.6.6 PN-EN 50182:2002 p. 6.4.4 PN-EN 50540:2010 p. 6.4.4 PN-EN 62219:2003 p. 6.6.6 PN-EN 62420:2008 p. 6.3.5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody Conductors Kierunek skrętu Metoda badania wizualnego Lay direction Visual examination method PN-IEC 1089:1994 p. 6.6.6 PN-EN 50182:2002 p. 6.4.4 PN-EN 50540:2010 p. 6.4.4 PN-EN 62219:2003 p. 6.6.6 PN-EN 62420:2008 p. 6.3.5 Przewody Conductors Kierunek skretu Metoda badania wizualnego Lay direction Visual examination method PN-IEC 1089:1994 p. 6.6.6 PN-EN 50182:2002 p. 6.4.4 PN-EN 50540:2010 p. 6.4.4 PN-EN 62219:2003 p. 6.6.6 PN-EN 62420:2008 p. 6.3.5","categories":["other"],"row_index":60,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Conductors Lay direction Visual examination method PN-IEC 1089:1994 p. 6.6.6 PN-EN 50182:2002 p. 6.4.4 PN-EN 50540:2010 p. 6.4.4 PN-EN 62219:2003 p. 6.6.6 PN-EN 62420:2008 p. 6.3.5","search_zh":"导线 Conductors PN-IEC 1089:1994 p. 6.6.6 PN-EN 50182:2002 p. 6.4.4 PN-EN 50540:2010 p. 6.4.4 PN-EN 62219:2003 p. 6.6.6 PN-EN 62420:2008 p. 6.3.5","test_object_zh":"导线 Conductors"},{"_id":"6a5a55ef9af9f73f38250ad9","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Przewody Conductors","test_object_en":"Conductors","methodology":"Bezwładność Metoda badania wizualnego Inertness Visual examination method","methodology_en":"Inertness Visual examination method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Bezwładność Metoda badania wizualnego Inertness Visual examination method","reference":"PN-EN 50182:2002 p. 6.4.3 PN-EN 50540:2010 p. 6.4.3","norm_bases":["PN-EN 50182:2002 p. 6.4.3 PN-EN 50540:2010 p. 6.4.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody Conductors Bezwładność Metoda badania wizualnego Inertness Visual examination method PN-EN 50182:2002 p. 6.4.3 PN-EN 50540:2010 p. 6.4.3 Przewody Conductors Bezwladnosc Metoda badania wizualnego Inertness Visual examination method PN-EN 50182:2002 p. 6.4.3 PN-EN 50540:2010 p. 6.4.3","categories":["other"],"row_index":61,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Conductors Inertness Visual examination method PN-EN 50182:2002 p. 6.4.3 PN-EN 50540:2010 p. 6.4.3","search_zh":"导线 Conductors PN-EN 50182:2002 p. 6.4.3 PN-EN 50540:2010 p. 6.4.3","test_object_zh":"导线 Conductors"},{"_id":"6a5a55ef9af9f73f38250ada","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Przewody Conductors","test_object_en":"Conductors","methodology":"Liczba i rodzaj drutów Metoda badania wizualnego Number and type of wires Visual examination method","methodology_en":"Number and type of wires Visual examination method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba i rodzaj drutów Metoda badania wizualnego Number and type of wires Visual examination method","reference":"PN-EN 50182:2002 p. 6.4.5 PN-EN 50540:2010 p. 6.4.5","norm_bases":["PN-EN 50182:2002 p. 6.4.5 PN-EN 50540:2010 p. 6.4.5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody Conductors Liczba i rodzaj drutów Metoda badania wizualnego Number and type of wires Visual examination method PN-EN 50182:2002 p. 6.4.5 PN-EN 50540:2010 p. 6.4.5 Przewody Conductors Liczba i rodzaj drutow Metoda badania wizualnego Number and type of wires Visual examination method PN-EN 50182:2002 p. 6.4.5 PN-EN 50540:2010 p. 6.4.5","categories":["other"],"row_index":62,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Conductors Number and type of wires Visual examination method PN-EN 50182:2002 p. 6.4.5 PN-EN 50540:2010 p. 6.4.5","search_zh":"导线 Conductors PN-EN 50182:2002 p. 6.4.5 PN-EN 50540:2010 p. 6.4.5","test_object_zh":"导线 Conductors"},{"_id":"6a5a55ef9af9f73f38250adb","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Przewody Conductors","test_object_en":"Conductors","methodology":"Jakość powierzchni Metoda badania wizualnego Surface quality Visual examination method","methodology_en":"Surface quality Visual examination method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Jakość powierzchni Metoda badania wizualnego Surface quality Visual examination method","reference":"PN-IEC 1089:1994 p. 6.6.5 PN-EN 50182:2002 p. 6.4.1 PN-EN 50540:2010 p. 6.4.1 PN-EN 62219:2003 p. 6.6.5 PN-EN 62420:2008 p. 6.3.4","norm_bases":["PN-IEC 1089:1994 p. 6.6.5 PN-EN 50182:2002 p. 6.4.1 PN-EN 50540:2010 p. 6.4.1 PN-EN 62219:2003 p. 6.6.5 PN-EN 62420:2008 p. 6.3.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody Conductors Jakość powierzchni Metoda badania wizualnego Surface quality Visual examination method PN-IEC 1089:1994 p. 6.6.5 PN-EN 50182:2002 p. 6.4.1 PN-EN 50540:2010 p. 6.4.1 PN-EN 62219:2003 p. 6.6.5 PN-EN 62420:2008 p. 6.3.4 Przewody Conductors Jakosc powierzchni Metoda badania wizualnego Surface quality Visual examination method PN-IEC 1089:1994 p. 6.6.5 PN-EN 50182:2002 p. 6.4.1 PN-EN 50540:2010 p. 6.4.1 PN-EN 62219:2003 p. 6.6.5 PN-EN 62420:2008 p. 6.3.4","categories":["other"],"row_index":63,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Conductors Surface quality Visual examination method PN-IEC 1089:1994 p. 6.6.5 PN-EN 50182:2002 p. 6.4.1 PN-EN 50540:2010 p. 6.4.1 PN-EN 62219:2003 p. 6.6.5 PN-EN 62420:2008 p. 6.3.4","search_zh":"导线 Conductors PN-IEC 1089:1994 p. 6.6.5 PN-EN 50182:2002 p. 6.4.1 PN-EN 50540:2010 p. 6.4.1 PN-EN 62219:2003 p. 6.6.5 PN-EN 62420:2008 p. 6.3.4","test_object_zh":"导线 Conductors"},{"_id":"6a5a55ef9af9f73f38250adc","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Przewody Conductors","test_object_en":"Conductors","methodology":"Masa jednostkowa długości. Masa smaru Zakres: (0 – 50) kg/m Metoda pomiaru bezpośredniego Mass per unit length. Mass of grease Range: (0 – 50) kg/m Direct measurement method","methodology_en":"Mass per unit length. Mass of grease Range: (0 – 50) kg/m Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Masa jednostkowa długości. Masa smaru Zakres: (0 – 50) kg/m Metoda pomiaru bezpośredniego Mass per unit length. Mass of grease Range: (0 – 50) kg/m Direct measurement method","reference":"PN-IEC 1089:1994 p. 6.6.3+Zał. C /annex C PN-EN 50182:2002 p. 6.4.6+Zał. B /annex B PN-EN 50540:2010 p. 6.4.7 PN-EN 62219:2003 p. 6.6.3+Zał. C /annex C PN-EN 62420:2008 p. 6.3.3+Zał. C /annex C","norm_bases":["PN-IEC 1089:1994 p. 6.6.3+Zał. C /annex C PN-EN 50182:2002 p. 6.4.6+Zał. B /annex B PN-EN 50540:2010 p. 6.4.7 PN-EN 62219:2003 p. 6.6.3+Zał. C /annex C PN-EN 62420:2008 p. 6.3.3+Zał. C /annex C"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody Conductors Masa jednostkowa długości. Masa smaru Zakres: (0 – 50) kg/m Metoda pomiaru bezpośredniego Mass per unit length. Mass of grease Range: (0 – 50) kg/m Direct measurement method PN-IEC 1089:1994 p. 6.6.3+Zał. C /annex C PN-EN 50182:2002 p. 6.4.6+Zał. B /annex B PN-EN 50540:2010 p. 6.4.7 PN-EN 62219:2003 p. 6.6.3+Zał. C /annex C PN-EN 62420:2008 p. 6.3.3+Zał. C /annex C Przewody Conductors Masa jednostkowa dlugosci. Masa smaru Zakres: (0 – 50) kg/m Metoda pomiaru bezposredniego Mass per unit length. Mass of grease Range: (0 – 50) kg/m Direct measurement method PN-IEC 1089:1994 p. 6.6.3+Zal. C /annex C PN-EN 50182:2002 p. 6.4.6+Zal. B /annex B PN-EN 50540:2010 p. 6.4.7 PN-EN 62219:2003 p. 6.6.3+Zal. C /annex C PN-EN 62420:2008 p. 6.3.3+Zal. C /annex C","categories":["petro"],"row_index":64,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Conductors Mass per unit length. Mass of grease Range: (0 – 50) kg/m Direct measurement method PN-IEC 1089:1994 p. 6.6.3+Zał. C /annex C PN-EN 50182:2002 p. 6.4.6+Zał. B /annex B PN-EN 50540:2010 p. 6.4.7 PN-EN 62219:2003 p. 6.6.3+Zał. C /annex C PN-EN 62420:2008 p. 6.3.3+Zał. C /annex C","search_zh":"导线 Conductors PN-IEC 1089:1994 p. 6.6.3+Zał. C /annex C PN-EN 50182:2002 p. 6.4.6+Zał. B /annex B PN-EN 50540:2010 p. 6.4.7 PN-EN 62219:2003 p. 6.6.3+Zał. C /annex C PN-EN 62420:2008 p. 6.3.3+Zał. C /annex C","test_object_zh":"导线 Conductors"},{"_id":"6a5a55ef9af9f73f38250add","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Przewody Conductors","test_object_en":"Conductors","methodology":"Pole przekroju Metoda pomiaru bezpośredniego Cross-sectional area Direct measurement method","methodology_en":"Cross-sectional area Direct measurement method Cross-sectional area Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pole przekroju Metoda pomiaru bezpośredniego Cross-sectional area Direct measurement method","reference":"PN-IEC 1089:1994 p. 6.6.1 PN-EN 50540:2010 p. 6.4.6 PN-EN 62219:2003 p. 6.6.1 PN-EN 62420:2008 p. 6.3.1","norm_bases":["PN-IEC 1089:1994 p. 6.6.1 PN-EN 50540:2010 p. 6.4.6 PN-EN 62219:2003 p. 6.6.1 PN-EN 62420:2008 p. 6.3.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody Conductors Pole przekroju Metoda pomiaru bezpośredniego Cross-sectional area Direct measurement method PN-IEC 1089:1994 p. 6.6.1 PN-EN 50540:2010 p. 6.4.6 PN-EN 62219:2003 p. 6.6.1 PN-EN 62420:2008 p. 6.3.1 Przewody Conductors Pole przekroju Metoda pomiaru bezposredniego Cross-sectional area Direct measurement method PN-IEC 1089:1994 p. 6.6.1 PN-EN 50540:2010 p. 6.4.6 PN-EN 62219:2003 p. 6.6.1 PN-EN 62420:2008 p. 6.3.1","categories":["other"],"row_index":65,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Conductors Cross-sectional area Direct measurement method Cross-sectional area Direct measurement method PN-IEC 1089:1994 p. 6.6.1 PN-EN 50540:2010 p. 6.4.6 PN-EN 62219:2003 p. 6.6.1 PN-EN 62420:2008 p. 6.3.1","search_zh":"导线 Conductors PN-IEC 1089:1994 p. 6.6.1 PN-EN 50540:2010 p. 6.4.6 PN-EN 62219:2003 p. 6.6.1 PN-EN 62420:2008 p. 6.3.1","test_object_zh":"导线 Conductors"},{"_id":"6a5a55ef9af9f73f38250ade","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Przewody Conductors","test_object_en":"Conductors","methodology":"Współczynnik wyślizgu Próba wyślizgu Slippage factor Slippage test","methodology_en":"Slippage factor Slippage test Slippage factor Slippage test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Współczynnik wyślizgu Próba wyślizgu Slippage factor Slippage test","reference":"PN-EN 50397-1:2007 Zał. D/annex D","norm_bases":["PN-EN 50397-1:2007 Zał. D/annex D"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody Conductors Współczynnik wyślizgu Próba wyślizgu Slippage factor Slippage test PN-EN 50397-1:2007 Zał. D/annex D Przewody Conductors Wspolczynnik wyslizgu Proba wyslizgu Slippage factor Slippage test PN-EN 50397-1:2007 Zal. D/annex D","categories":["other"],"row_index":66,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Conductors Slippage factor Slippage test Slippage factor Slippage test PN-EN 50397-1:2007 Zał. D/annex D","search_zh":"导线 Conductors PN-EN 50397-1:2007 Zał. D/annex D","test_object_zh":"导线 Conductors"},{"_id":"6a5a55ef9af9f73f38250adf","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Druty Wires","test_object_en":"Wires","methodology":"Średnica Zakres: (0 – 300) mm Metoda pomiaru bezpośredniego Diameter Range: (0 – 300) mm Direct measurement method","methodology_en":"Diameter Range: (0 – 300) mm Direct measurement method Diameter Range: (0 – 300) mm Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Średnica Zakres: (0 – 300) mm Metoda pomiaru bezpośredniego Diameter Range: (0 – 300) mm Direct measurement method","reference":"PN-IEC 1089:1994 Zał. NA/annex NA p. 5 PN-IEC 1089:1994 Zał. NB/annex NB p. 5 PN-IEC 1089:1994 Zał. NC/annex NC p. 5","norm_bases":["PN-IEC 1089:1994 Zał. NA/annex NA p. 5 PN-IEC 1089:1994 Zał. NB/annex NB p. 5 PN-IEC 1089:1994 Zał. NC/annex NC p. 5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Druty Wires Średnica Zakres: (0 – 300) mm Metoda pomiaru bezpośredniego Diameter Range: (0 – 300) mm Direct measurement method PN-IEC 1089:1994 Zał. NA/annex NA p. 5 PN-IEC 1089:1994 Zał. NB/annex NB p. 5 PN-IEC 1089:1994 Zał. NC/annex NC p. 5 Druty Wires Srednica Zakres: (0 – 300) mm Metoda pomiaru bezposredniego Diameter Range: (0 – 300) mm Direct measurement method PN-IEC 1089:1994 Zal. NA/annex NA p. 5 PN-IEC 1089:1994 Zal. NB/annex NB p. 5 PN-IEC 1089:1994 Zal. NC/annex NC p. 5","categories":["other"],"row_index":67,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wires Diameter Range: (0 – 300) mm Direct measurement method Diameter Range: (0 – 300) mm Direct measurement method PN-IEC 1089:1994 Zał. NA/annex NA p. 5 PN-IEC 1089:1994 Zał. NB/annex NB p. 5 PN-IEC 1089:1994 Zał. NC/annex NC p. 5","search_zh":"钢丝 Wires PN-IEC 1089:1994 Zał. NA/annex NA p. 5 PN-IEC 1089:1994 Zał. NB/annex NB p. 5 PN-IEC 1089:1994 Zał. NC/annex NC p. 5","test_object_zh":"钢丝 Wires"},{"_id":"6a5a55ef9af9f73f38250ae0","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Druty Wires","test_object_en":"Wires","methodology":"Siła rozciągająca Zakres: (0 – 100) kN Próba rozciągania Tensile force Range: (0 – 100) kN Tensile test","methodology_en":"Tensile force Range: (0 – 100) kN Tensile test Tensile force Range: (0 – 100) kN Tensile test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła rozciągająca Zakres: (0 – 100) kN Próba rozciągania Tensile force Range: (0 – 100) kN Tensile test","reference":"PN-IEC 1089:1994 p. 6.6.4 PN-IEC 1089:1994 Zał. NA/annex NA p. 10.1 PN-IEC 1089:1994 Zał. NB/annex NB p. 10.2 PN-IEC 1089:1994 Zał. NC/annex NC p. 10","norm_bases":["PN-IEC 1089:1994 p. 6.6.4 PN-IEC 1089:1994 Zał. NA/annex NA p. 10.1 PN-IEC 1089:1994 Zał. NB/annex NB p. 10.2 PN-IEC 1089:1994 Zał. NC/annex NC p. 10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Druty Wires Siła rozciągająca Zakres: (0 – 100) kN Próba rozciągania Tensile force Range: (0 – 100) kN Tensile test PN-IEC 1089:1994 p. 6.6.4 PN-IEC 1089:1994 Zał. NA/annex NA p. 10.1 PN-IEC 1089:1994 Zał. NB/annex NB p. 10.2 PN-IEC 1089:1994 Zał. NC/annex NC p. 10 Druty Wires Sila rozciagajaca Zakres: (0 – 100) kN Proba rozciagania Tensile force Range: (0 – 100) kN Tensile test PN-IEC 1089:1994 p. 6.6.4 PN-IEC 1089:1994 Zal. NA/annex NA p. 10.1 PN-IEC 1089:1994 Zal. NB/annex NB p. 10.2 PN-IEC 1089:1994 Zal. NC/annex NC p. 10","categories":["other"],"row_index":68,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wires Tensile force Range: (0 – 100) kN Tensile test Tensile force Range: (0 – 100) kN Tensile test PN-IEC 1089:1994 p. 6.6.4 PN-IEC 1089:1994 Zał. NA/annex NA p. 10.1 PN-IEC 1089:1994 Zał. NB/annex NB p. 10.2 PN-IEC 1089:1994 Zał. NC/annex NC p. 10","search_zh":"钢丝 Wires PN-IEC 1089:1994 p. 6.6.4 PN-IEC 1089:1994 Zał. NA/annex NA p. 10.1 PN-IEC 1089:1994 Zał. NB/annex NB p. 10.2 PN-IEC 1089:1994 Zał. NC/annex NC p. 10","test_object_zh":"钢丝 Wires"},{"_id":"6a5a55ef9af9f73f38250ae1","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Druty Wires","test_object_en":"Wires","methodology":"Zdolność do nawijania Próba nawijania Ability for wrapping Wrapping test","methodology_en":"Ability for wrapping Wrapping test Ability for wrapping Wrapping test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność do nawijania Próba nawijania Ability for wrapping Wrapping test","reference":"PN-EN 50182:2002 p. 6.5.2 PN-EN 50183:2002 p. 11.4 PN-EN 60889:2002 p. 10.2","norm_bases":["PN-EN 50182:2002 p. 6.5.2 PN-EN 50183:2002 p. 11.4 PN-EN 60889:2002 p. 10.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Druty Wires Zdolność do nawijania Próba nawijania Ability for wrapping Wrapping test PN-EN 50182:2002 p. 6.5.2 PN-EN 50183:2002 p. 11.4 PN-EN 60889:2002 p. 10.2 Druty Wires Zdolnosc do nawijania Proba nawijania Ability for wrapping Wrapping test PN-EN 50182:2002 p. 6.5.2 PN-EN 50183:2002 p. 11.4 PN-EN 60889:2002 p. 10.2","categories":["other"],"row_index":69,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wires Ability for wrapping Wrapping test Ability for wrapping Wrapping test PN-EN 50182:2002 p. 6.5.2 PN-EN 50183:2002 p. 11.4 PN-EN 60889:2002 p. 10.2","search_zh":"钢丝 Wires PN-EN 50182:2002 p. 6.5.2 PN-EN 50183:2002 p. 11.4 PN-EN 60889:2002 p. 10.2","test_object_zh":"钢丝 Wires"},{"_id":"6a5a55ef9af9f73f38250ae2","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Stal do sprężania betonu Steel for prestressing of concrete","test_object_en":"Steel for prestressing of concrete","methodology":"Siła zrywająca Zakres: siła (0 – 5000) kN Metoda obciążania siłą Breaking force Range: force (0 – 5000) kN Force method","methodology_en":"Breaking force Range: force (0 – 5000) kN Force method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła zrywająca Zakres: siła (0 – 5000) kN Metoda obciążania siłą Breaking force Range: force (0 – 5000) kN Force method","reference":"PN-EN ISO 15630-3:2011 p. 5.3.1","norm_bases":["PN-EN ISO 15630-3:2011 p. 5.3.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stal do sprężania betonu Steel for prestressing of concrete Siła zrywająca Zakres: siła (0 – 5000) kN Metoda obciążania siłą Breaking force Range: force (0 – 5000) kN Force method PN-EN ISO 15630-3:2011 p. 5.3.1 Stal do sprezania betonu Steel for prestressing of concrete Sila zrywajaca Zakres: sila (0 – 5000) kN Metoda obciazania sila Breaking force Range: force (0 – 5000) kN Force method PN-EN ISO 15630-3:2011 p. 5.3.1","categories":["construction","materials"],"row_index":70,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Steel for prestressing of concrete Breaking force Range: force (0 – 5000) kN Force method PN-EN ISO 15630-3:2011 p. 5.3.1","search_zh":"预应力混凝土用钢 Steel for prestressing of concrete PN-EN ISO 15630-3:2011 p. 5.3.1","test_object_zh":"预应力混凝土用钢 Steel for prestressing of concrete"},{"_id":"6a5a55ef9af9f73f38250ae3","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Stal do sprężania betonu Steel for prestressing of concrete","test_object_en":"Steel for prestressing of concrete","methodology":"Wydłużenie Zakres: (0 – 2000) mm Metoda pomiaru bezpośredniego Elongation Range: (0 – 2000) mm Direct measurement method","methodology_en":"Elongation Range: (0 – 2000) mm Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wydłużenie Zakres: (0 – 2000) mm Metoda pomiaru bezpośredniego Elongation Range: (0 – 2000) mm Direct measurement method","reference":"PN-EN ISO 15630-3:2011 p. 5.3.1","norm_bases":["PN-EN ISO 15630-3:2011 p. 5.3.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stal do sprężania betonu Steel for prestressing of concrete Wydłużenie Zakres: (0 – 2000) mm Metoda pomiaru bezpośredniego Elongation Range: (0 – 2000) mm Direct measurement method PN-EN ISO 15630-3:2011 p. 5.3.1 Stal do sprezania betonu Steel for prestressing of concrete Wydluzenie Zakres: (0 – 2000) mm Metoda pomiaru bezposredniego Elongation Range: (0 – 2000) mm Direct measurement method PN-EN ISO 15630-3:2011 p. 5.3.1","categories":["construction","materials"],"row_index":71,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Steel for prestressing of concrete Elongation Range: (0 – 2000) mm Direct measurement method PN-EN ISO 15630-3:2011 p. 5.3.1","methodology_zh":"伸长 范围：(0 – 2000) mm 直接测量法 Elongation Range: (0 – 2000) mm Direct measurement method","search_zh":"预应力混凝土用钢 Steel for prestressing of concrete 伸长 范围：(0 – 2000) mm 直接测量法 Elongation Range: (0 – 2000) mm Direct measurement method PN-EN ISO 15630-3:2011 p. 5.3.1","test_object_zh":"预应力混凝土用钢 Steel for prestressing of concrete"},{"_id":"6a5a55ef9af9f73f38250ae4","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Stal do sprężania betonu Steel for prestressing of concrete","test_object_en":"Steel for prestressing of concrete","methodology":"Moduł sprężystości Cecha z obliczeń Zakres: siła (0 – 5000) kN Zakres: wydłużenie (0 – 5000) mm Modulus of elasticity (calculated) Range: force (0 – 5000) kN Range: elongation (0 – 5000) mm","methodology_en":"Modulus of elasticity (calculated) Range: force (0 – 5000) kN Range: elongation (0 – 5000) mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moduł sprężystości Cecha z obliczeń Zakres: siła (0 – 5000) kN Zakres: wydłużenie (0 – 5000) mm Modulus of elasticity (calculated) Range: force (0 – 5000) kN Range: elongation (0 – 5000) mm","reference":"PN-EN ISO 15630-3:2011 p. 5.3.2","norm_bases":["PN-EN ISO 15630-3:2011 p. 5.3.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stal do sprężania betonu Steel for prestressing of concrete Moduł sprężystości Cecha z obliczeń Zakres: siła (0 – 5000) kN Zakres: wydłużenie (0 – 5000) mm Modulus of elasticity (calculated) Range: force (0 – 5000) kN Range: elongation (0 – 5000) mm PN-EN ISO 15630-3:2011 p. 5.3.2 Stal do sprezania betonu Steel for prestressing of concrete Modul sprezystosci Cecha z obliczen Zakres: sila (0 – 5000) kN Zakres: wydluzenie (0 – 5000) mm Modulus of elasticity (calculated) Range: force (0 – 5000) kN Range: elongation (0 – 5000) mm PN-EN ISO 15630-3:2011 p. 5.3.2","categories":["construction","materials"],"row_index":72,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Steel for prestressing of concrete Modulus of elasticity (calculated) Range: force (0 – 5000) kN Range: elongation (0 – 5000) mm PN-EN ISO 15630-3:2011 p. 5.3.2","search_zh":"预应力混凝土用钢 Steel for prestressing of concrete PN-EN ISO 15630-3:2011 p. 5.3.2","test_object_zh":"预应力混凝土用钢 Steel for prestressing of concrete"},{"_id":"6a5a55ef9af9f73f38250ae5","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Elementy konstrukcji technicznych Elements of technical constructions","test_object_en":"Elements of technical constructions","methodology":"Wymiary liniowe Metoda pomiaru bezpośredniego Statyczna próba zginania Zakres: - siła do 3000 kN - przemieszczenie do 0,35 m Metoda obciążenia siłą z pomiarem przemieszczenia Linear dimensions Direct measurement method Static bend test Range: - force up to 3000 kN - displacement up to 0,35 m Force method with displacement measurement","methodology_en":"Linear dimensions Direct measurement method Static bend test Range: - force up to 3000 kN - displacement up to 0,35 m Force method with displacement measurement","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary liniowe Metoda pomiaru bezpośredniego Statyczna próba zginania Zakres: - siła do 3000 kN - przemieszczenie do 0,35 m Metoda obciążenia siłą z pomiarem przemieszczenia Linear dimensions Direct measurement method Static bend test Range: - force up to 3000 kN - displacement up to 0,35 m Force method with displacement measurement","reference":"PN-G-15000-9:1998 PN-G-06021:1997 z wyłączeniem /excluding p. 5.3.3 PN-G-15541:1997 DIN 21530-4:2003 p. 4.1.1.2.2.5","norm_bases":["PN-G-15000-9:1998 PN-G-06021:1997 z wyłączeniem /excluding p. 5.3.3 PN-G-15541:1997 DIN 21530-4:2003 p. 4.1.1.2.2.5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy konstrukcji technicznych Elements of technical constructions Wymiary liniowe Metoda pomiaru bezpośredniego Statyczna próba zginania Zakres: - siła do 3000 kN - przemieszczenie do 0,35 m Metoda obciążenia siłą z pomiarem przemieszczenia Linear dimensions Direct measurement method Static bend test Range: - force up to 3000 kN - displacement up to 0,35 m Force method with displacement measurement PN-G-15000-9:1998 PN-G-06021:1997 z wyłączeniem /excluding p. 5.3.3 PN-G-15541:1997 DIN 21530-4:2003 p. 4.1.1.2.2.5 Elementy konstrukcji technicznych Elements of technical constructions Wymiary liniowe Metoda pomiaru bezposredniego Statyczna proba zginania Zakres: - sila do 3000 kN - przemieszczenie do 0,35 m Metoda obciazenia sila z pomiarem przemieszczenia Linear dimensions Direct measurement method Static bend test Range: - force up to 3000 kN - displacement up to 0,35 m Force method with displacement measurement PN-G-15000-9:1998 PN-G-06021:1997 z wylaczeniem /excluding p. 5.3.3 PN-G-15541:1997 DIN 21530-4:2003 p. 4.1.1.2.2.5","categories":["construction"],"row_index":73,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Elements of technical constructions Linear dimensions Direct measurement method Static bend test Range: - force up to 3000 kN - displacement up to 0,35 m Force method with displacement measurement PN-G-15000-9:1998 PN-G-06021:1997 z wyłączeniem /excluding p. 5.3.3 PN-G-15541:1997 DIN 21530-4:2003 p. 4.1.1.2.2.5"},{"_id":"6a5a55ef9af9f73f38250ae6","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Elementy konstrukcji technicznych Elements of technical constructions","test_object_en":"Elements of technical constructions","methodology":"Wymiary liniowe Metoda pomiaru bezpośredniego Statyczna próba skręcania Zakres: - moment skręcający do 170 kNm - kąt obrotu do 180 Metoda obciążenia momentem skręcającym z pomiarem kąta obrotu Linear dimensions Direct measurement method Static torsion test Range: - torsion moment up to 170 kNm - rotation angle up to 180º Torque loading method with rotation angle measurement","methodology_en":"Linear dimensions Direct measurement method Static torsion test Range: - torsion moment up to 170 kNm - rotation angle up to 180º Torque loading method with rotation angle measurement","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary liniowe Metoda pomiaru bezpośredniego Statyczna próba skręcania Zakres: - moment skręcający do 170 kNm - kąt obrotu do 180 Metoda obciążenia momentem skręcającym z pomiarem kąta obrotu Linear dimensions Direct measurement method Static torsion test Range: - torsion moment up to 170 kNm - rotation angle up to 180º Torque loading method with rotation angle measurement","reference":"PN-G-15000-12:1994","norm_bases":["PN-G-15000-12:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy konstrukcji technicznych Elements of technical constructions Wymiary liniowe Metoda pomiaru bezpośredniego Statyczna próba skręcania Zakres: - moment skręcający do 170 kNm - kąt obrotu do 180 Metoda obciążenia momentem skręcającym z pomiarem kąta obrotu Linear dimensions Direct measurement method Static torsion test Range: - torsion moment up to 170 kNm - rotation angle up to 180º Torque loading method with rotation angle measurement PN-G-15000-12:1994 Elementy konstrukcji technicznych Elements of technical constructions Wymiary liniowe Metoda pomiaru bezposredniego Statyczna proba skrecania Zakres: - moment skrecajacy do 170 kNm - kat obrotu do 180 Metoda obciazenia momentem skrecajacym z pomiarem kata obrotu Linear dimensions Direct measurement method Static torsion test Range: - torsion moment up to 170 kNm - rotation angle up to 180º Torque loading method with rotation angle measurement PN-G-15000-12:1994","categories":["construction"],"row_index":74,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Elements of technical constructions Linear dimensions Direct measurement method Static torsion test Range: - torsion moment up to 170 kNm - rotation angle up to 180º Torque loading method with rotation angle measurement PN-G-15000-12:1994"},{"_id":"6a5a55ef9af9f73f38250ae7","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Cierne stojaki podporowe Friction props","test_object_en":"Friction props","methodology":"Wymiary liniowe Metoda pomiaru bezpośredniego Masa stojaka Metoda wagowa Średnia podporność robocza Zakres: - siła do 3000 kN - wysokość stojaka do 4,5 m Metoda obciążenia siłą Odporność dynamiczna Zakres: - wysokość stojaka do 4,5 m - energia udaru do 49x104 J Metoda swobodnie spadającej masy Linear dimensions Direct measurement method Prop mass Weight method Average working load Range: - force up to 3000 kN - prop height up to 4,5 m Force method Dynamic resistance Range: - prop height up to 4,5 m - impact energy up to 49x104 J Free falling mass method","methodology_en":"Linear dimensions Direct measurement method Prop mass Weight method Average working load Range: - force up to 3000 kN - prop height up to 4,5 m Force method Dynamic resistance Range: - prop height up to 4,5 m - impact energy up to 49x104 J Free falling mass method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary liniowe Metoda pomiaru bezpośredniego Masa stojaka Metoda wagowa Średnia podporność robocza Zakres: - siła do 3000 kN - wysokość stojaka do 4,5 m Metoda obciążenia siłą Odporność dynamiczna Zakres: - wysokość stojaka do 4,5 m - energia udaru do 49x104 J Metoda swobodnie spadającej masy Linear dimensions Direct measurement method Prop mass Weight method Average working load Range: - force up to 3000 kN - prop height up to 4,5 m Force method Dynamic resistance Range: - prop height up to 4,5 m - impact energy up to 49x104 J Free falling mass method","reference":"PN-G-15533:1997","norm_bases":["PN-G-15533:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Cierne stojaki podporowe Friction props Wymiary liniowe Metoda pomiaru bezpośredniego Masa stojaka Metoda wagowa Średnia podporność robocza Zakres: - siła do 3000 kN - wysokość stojaka do 4,5 m Metoda obciążenia siłą Odporność dynamiczna Zakres: - wysokość stojaka do 4,5 m - energia udaru do 49x104 J Metoda swobodnie spadającej masy Linear dimensions Direct measurement method Prop mass Weight method Average working load Range: - force up to 3000 kN - prop height up to 4,5 m Force method Dynamic resistance Range: - prop height up to 4,5 m - impact energy up to 49x104 J Free falling mass method PN-G-15533:1997 Cierne stojaki podporowe Friction props Wymiary liniowe Metoda pomiaru bezposredniego Masa stojaka Metoda wagowa Srednia podpornosc robocza Zakres: - sila do 3000 kN - wysokosc stojaka do 4,5 m Metoda obciazenia sila Odpornosc dynamiczna Zakres: - wysokosc stojaka do 4,5 m - energia udaru do 49x104 J Metoda swobodnie spadajacej masy Linear dimensions Direct measurement method Prop mass Weight method Average working load Range: - force up to 3000 kN - prop height up to 4,5 m Force method Dynamic resistance Range: - prop height up to 4,5 m - impact energy up to 49x104 J Free falling mass method PN-G-15533:1997","categories":["other"],"row_index":75,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Friction props Linear dimensions Direct measurement method Prop mass Weight method Average working load Range: - force up to 3000 kN - prop height up to 4,5 m Force method Dynamic resistance Range: - prop height up to 4,5 m - impact energy up to 49x104 J Free falling mass method PN-G-15533:1997"},{"_id":"6a5a55ef9af9f73f38250ae8","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Stojaki hydrauliczne Hydraulic props","test_object_en":"Hydraulic props","methodology":"Wymiary liniowe Metoda pomiaru bezpośredniego Odporność dynamiczna Zakres: - energia udaru do 49104 J - wysokość stojaka do 6 m - masa udarowa do 20000 kg Metoda swobodnie spadającej masy Linear dimensions Direct measurement method Dynamic resistance Range: - impact energy up to 49104 J - prop height up to 6 m - impact mass up to 20000 kg Free falling mass method","methodology_en":"Linear dimensions Direct measurement method Dynamic resistance Range: - impact energy up to 49104 J - prop height up to 6 m - impact mass up to 20000 kg Free falling mass method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary liniowe Metoda pomiaru bezpośredniego Odporność dynamiczna Zakres: - energia udaru do 49104 J - wysokość stojaka do 6 m - masa udarowa do 20000 kg Metoda swobodnie spadającej masy Linear dimensions Direct measurement method Dynamic resistance Range: - impact energy up to 49104 J - prop height up to 6 m - impact mass up to 20000 kg Free falling mass method","reference":"PN-G-15536:2013 p. 6.4.2.4","norm_bases":["PN-G-15536:2013 p. 6.4.2.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stojaki hydrauliczne Hydraulic props Wymiary liniowe Metoda pomiaru bezpośredniego Odporność dynamiczna Zakres: - energia udaru do 49104 J - wysokość stojaka do 6 m - masa udarowa do 20000 kg Metoda swobodnie spadającej masy Linear dimensions Direct measurement method Dynamic resistance Range: - impact energy up to 49104 J - prop height up to 6 m - impact mass up to 20000 kg Free falling mass method PN-G-15536:2013 p. 6.4.2.4 Stojaki hydrauliczne Hydraulic props Wymiary liniowe Metoda pomiaru bezposredniego Odpornosc dynamiczna Zakres: - energia udaru do 49104 J - wysokosc stojaka do 6 m - masa udarowa do 20000 kg Metoda swobodnie spadajacej masy Linear dimensions Direct measurement method Dynamic resistance Range: - impact energy up to 49104 J - prop height up to 6 m - impact mass up to 20000 kg Free falling mass method PN-G-15536:2013 p. 6.4.2.4","categories":["other"],"row_index":76,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Hydraulic props Linear dimensions Direct measurement method Dynamic resistance Range: - impact energy up to 49104 J - prop height up to 6 m - impact mass up to 20000 kg Free falling mass method PN-G-15536:2013 p. 6.4.2.4"},{"_id":"6a5a55ef9af9f73f38250ae9","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Stojaki hydrauliczne Hydraulic props","test_object_en":"Hydraulic props","methodology":"Wymiary liniowe Metoda pomiaru bezpośredniego Prędkość zsuwu rdzennika Metoda obciążenia ciśnieniem z pomiarem przemieszczenia Przeciążalność statyczna osiowa Zakres: - przeciążalność do 13 MN - wysokość stojaka do 4,7 m Metoda obciążenia ciśnieniem z pomiarem przemieszczenia Przeciążalność statyczna mimośrodowa Zakres: - przeciążalność do 13 MN - wysokość stojaka do 4,7 m Metoda obciążenia ciśnieniem z pomiarem przemieszczenia Szczelność Metoda obciążenia ciśnieniem Charakterystyka podpornościowa Metoda obciążenia ciśnieniem z pomiarem przemieszczenia Linear dimensions Direct measurement method Piston displacement speed Static axial overload Range: - overload up to 13 MN - prop height up to 4,7 m Pressure loading method with displacement measurement Static eccentric overload Range: - overload up to 13 MN - prop height up to 4,7 m Pressure loading method with displacement measurement Tightness Pressure loading method Support characteristics Pressure loading method with displacement measurement","methodology_en":"Linear dimensions Direct measurement method Piston displacement speed Static axial overload Range: - overload up to 13 MN - prop height up to 4,7 m Pressure loading method with displacement measurement Static eccentric overload Range: - overload up to 13 MN - prop height up to 4,7 m Pressure loading method with displacement measurement Tightness Pressure loading method Support characteristics Pressure loading method with displacement measurement","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary liniowe Metoda pomiaru bezpośredniego Prędkość zsuwu rdzennika Metoda obciążenia ciśnieniem z pomiarem przemieszczenia Przeciążalność statyczna osiowa Zakres: - przeciążalność do 13 MN - wysokość stojaka do 4,7 m Metoda obciążenia ciśnieniem z pomiarem przemieszczenia Przeciążalność statyczna mimośrodowa Zakres: - przeciążalność do 13 MN - wysokość stojaka do 4,7 m Metoda obciążenia ciśnieniem z pomiarem przemieszczenia Szczelność Metoda obciążenia ciśnieniem Charakterystyka podpornościowa Metoda obciążenia ciśnieniem z pomiarem przemieszczenia Linear dimensions Direct measurement method Piston displacement speed Static axial overload Range: - overload up to 13 MN - prop height up to 4,7 m Pressure loading method with displacement measurement Static eccentric overload Range: - overload up to 13 MN - prop height up to 4,7 m Pressure loading method with displacement measurement Tightness Pressure loading method Support characteristics Pressure loading method with displacement measurement","reference":"PN-G-15536:2013 z wyłączeniem / /excluding p. 6.4.2.4 i/and 6.4.4 PN-EN 1804-2:2021-05 z wyłączeniem/excluding p. A.1.2.3.2","norm_bases":["PN-G-15536:2013 z wyłączeniem / /excluding p. 6.4.2.4 i/and 6.4.4 PN-EN 1804-2:2021-05 z wyłączeniem/excluding p. A.1.2.3.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stojaki hydrauliczne Hydraulic props Wymiary liniowe Metoda pomiaru bezpośredniego Prędkość zsuwu rdzennika Metoda obciążenia ciśnieniem z pomiarem przemieszczenia Przeciążalność statyczna osiowa Zakres: - przeciążalność do 13 MN - wysokość stojaka do 4,7 m Metoda obciążenia ciśnieniem z pomiarem przemieszczenia Przeciążalność statyczna mimośrodowa Zakres: - przeciążalność do 13 MN - wysokość stojaka do 4,7 m Metoda obciążenia ciśnieniem z pomiarem przemieszczenia Szczelność Metoda obciążenia ciśnieniem Charakterystyka podpornościowa Metoda obciążenia ciśnieniem z pomiarem przemieszczenia Linear dimensions Direct measurement method Piston displacement speed Static axial overload Range: - overload up to 13 MN - prop height up to 4,7 m Pressure loading method with displacement measurement Static eccentric overload Range: - overload up to 13 MN - prop height up to 4,7 m Pressure loading method with displacement measurement Tightness Pressure loading method Support characteristics Pressure loading method with displacement measurement PN-G-15536:2013 z wyłączeniem / /excluding p. 6.4.2.4 i/and 6.4.4 PN-EN 1804-2:2021-05 z wyłączeniem/excluding p. A.1.2.3.2 Stojaki hydrauliczne Hydraulic props Wymiary liniowe Metoda pomiaru bezposredniego Predkosc zsuwu rdzennika Metoda obciazenia cisnieniem z pomiarem przemieszczenia Przeciazalnosc statyczna osiowa Zakres: - przeciazalnosc do 13 MN - wysokosc stojaka do 4,7 m Metoda obciazenia cisnieniem z pomiarem przemieszczenia Przeciazalnosc statyczna mimosrodowa Zakres: - przeciazalnosc do 13 MN - wysokosc stojaka do 4,7 m Metoda obciazenia cisnieniem z pomiarem przemieszczenia Szczelnosc Metoda obciazenia cisnieniem Charakterystyka podpornosciowa Metoda obciazenia cisnieniem z pomiarem przemieszczenia Linear dimensions Direct measurement method Piston displacement speed Static axial overload Range: - overload up to 13 MN - prop height up to 4,7 m Pressure loading method with displacement measurement Static eccentric overload Range: - overload up to 13 MN - prop height up to 4,7 m Pressure loading method with displacement measurement Tightness Pressure loading method Support characteristics Pressure loading method with displacement measurement PN-G-15536:2013 z wylaczeniem / /excluding p. 6.4.2.4 i/and 6.4.4 PN-EN 1804-2:2021-05 z wylaczeniem/excluding p. A.1.2.3.2","categories":["other"],"row_index":77,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Hydraulic props Linear dimensions Direct measurement method Piston displacement speed Static axial overload Range: - overload up to 13 MN - prop height up to 4,7 m Pressure loading method with displacement measurement Static eccentric overload Range: - overload up to 13 MN - prop height up to 4,7 m Pressure loading method with displacement measurement Tightness Pressure loading method Support characteristics Pressure loading method with displacement measurement PN-G-15536:2013 z wyłączeniem / /excluding p. 6.4.2.4 i/and 6.4.4 PN-EN 1804-2:2021-05 z wyłączeniem/excluding p. A.1.2.3.2"},{"_id":"6a5a55ef9af9f73f38250aea","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Stojaki, podpory i siłowniki pomocnicze Props, legs, rams and auxiliary actuators","test_object_en":"Props, legs, rams and auxiliary actuators","methodology":"Podatność Metoda obciążenia ciśnieniem Przeciążenie statyczne Metoda obciążenia ciśnieniem Przeciążenie dynamiczne Metoda obciążenia ciśnieniem Trwałość Metoda obciążenia ciśnieniem Funkcjonalność (poprawność działania) Metoda obciążenia ciśnieniem Szczelność Metoda obciążenia ciśnieniem Ugięcie Zakres: - ciśnienie do 200 MPa - siła do 13 MN Metoda obciążenia ciśnieniem Susceptibility Pressure loading method Static overload Pressure loading method Dynamic overload Pressure loading method Durability Pressure loading method Functionality (correct operation) Pressure loading method Tightness Pressure loading method Deflection Range: - pressure up to 200 MPa - force up to 13 MN Pressure loading method","methodology_en":"Susceptibility Pressure loading method Static overload Pressure loading method Dynamic overload Pressure loading method Durability Pressure loading method Functionality (correct operation) Pressure loading method Tightness Pressure loading method Deflection Range: - pressure up to 200 MPa - force up to 13 MN Pressure loading method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Podatność Metoda obciążenia ciśnieniem Przeciążenie statyczne Metoda obciążenia ciśnieniem Przeciążenie dynamiczne Metoda obciążenia ciśnieniem Trwałość Metoda obciążenia ciśnieniem Funkcjonalność (poprawność działania) Metoda obciążenia ciśnieniem Szczelność Metoda obciążenia ciśnieniem Ugięcie Zakres: - ciśnienie do 200 MPa - siła do 13 MN Metoda obciążenia ciśnieniem Susceptibility Pressure loading method Static overload Pressure loading method Dynamic overload Pressure loading method Durability Pressure loading method Functionality (correct operation) Pressure loading method Tightness Pressure loading method Deflection Range: - pressure up to 200 MPa - force up to 13 MN Pressure loading method","reference":"PN-EN 1804-2:2021-05 Załączniki/annexes A i/and B","norm_bases":["PN-EN 1804-2:2021-05 Załączniki/annexes A i/and B"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stojaki, podpory i siłowniki pomocnicze Props, legs, rams and auxiliary actuators Podatność Metoda obciążenia ciśnieniem Przeciążenie statyczne Metoda obciążenia ciśnieniem Przeciążenie dynamiczne Metoda obciążenia ciśnieniem Trwałość Metoda obciążenia ciśnieniem Funkcjonalność (poprawność działania) Metoda obciążenia ciśnieniem Szczelność Metoda obciążenia ciśnieniem Ugięcie Zakres: - ciśnienie do 200 MPa - siła do 13 MN Metoda obciążenia ciśnieniem Susceptibility Pressure loading method Static overload Pressure loading method Dynamic overload Pressure loading method Durability Pressure loading method Functionality (correct operation) Pressure loading method Tightness Pressure loading method Deflection Range: - pressure up to 200 MPa - force up to 13 MN Pressure loading method PN-EN 1804-2:2021-05 Załączniki/annexes A i/and B Stojaki, podpory i silowniki pomocnicze Props, legs, rams and auxiliary actuators Podatnosc Metoda obciazenia cisnieniem Przeciazenie statyczne Metoda obciazenia cisnieniem Przeciazenie dynamiczne Metoda obciazenia cisnieniem Trwalosc Metoda obciazenia cisnieniem Funkcjonalnosc (poprawnosc dzialania) Metoda obciazenia cisnieniem Szczelnosc Metoda obciazenia cisnieniem Ugiecie Zakres: - cisnienie do 200 MPa - sila do 13 MN Metoda obciazenia cisnieniem Susceptibility Pressure loading method Static overload Pressure loading method Dynamic overload Pressure loading method Durability Pressure loading method Functionality (correct operation) Pressure loading method Tightness Pressure loading method Deflection Range: - pressure up to 200 MPa - force up to 13 MN Pressure loading method PN-EN 1804-2:2021-05 Zalaczniki/annexes A i/and B","categories":["other"],"row_index":78,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Props, legs, rams and auxiliary actuators Susceptibility Pressure loading method Static overload Pressure loading method Dynamic overload Pressure loading method Durability Pressure loading method Functionality (correct operation) Pressure loading method Tightness Pressure loading method Deflection Range: - pressure up to 200 MPa - force up to 13 MN Pressure loading method PN-EN 1804-2:2021-05 Załączniki/annexes A i/and B"},{"_id":"6a5a55ef9af9f73f38250aeb","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Elementy hydrauliki siłowej Power hydraulics elements","test_object_en":"Power hydraulics elements","methodology":"Odporność zmęczeniowa Metoda obciążenia ciśnieniem Szczelność Metoda obciążenia ciśnieniem Funkcjonalność (poprawność działania) Metoda obciążenia ciśnieniem Fatigue resistance Pressure loading method Tightness Pressure loading method Functionality (correct operation) Pressure loading method","methodology_en":"Fatigue resistance Pressure loading method Tightness Pressure loading method Functionality (correct operation) Pressure loading method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność zmęczeniowa Metoda obciążenia ciśnieniem Szczelność Metoda obciążenia ciśnieniem Funkcjonalność (poprawność działania) Metoda obciążenia ciśnieniem Fatigue resistance Pressure loading method Tightness Pressure loading method Functionality (correct operation) Pressure loading method","reference":"PN-G-15536:2013 p. 6.4.4, 6.4.4.4, 6.5 i/and 6.4.2.5","norm_bases":["PN-G-15536:2013 p. 6.4.4, 6.4.4.4, 6.5 i/and 6.4.2.5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy hydrauliki siłowej Power hydraulics elements Odporność zmęczeniowa Metoda obciążenia ciśnieniem Szczelność Metoda obciążenia ciśnieniem Funkcjonalność (poprawność działania) Metoda obciążenia ciśnieniem Fatigue resistance Pressure loading method Tightness Pressure loading method Functionality (correct operation) Pressure loading method PN-G-15536:2013 p. 6.4.4, 6.4.4.4, 6.5 i/and 6.4.2.5 Elementy hydrauliki silowej Power hydraulics elements Odpornosc zmeczeniowa Metoda obciazenia cisnieniem Szczelnosc Metoda obciazenia cisnieniem Funkcjonalnosc (poprawnosc dzialania) Metoda obciazenia cisnieniem Fatigue resistance Pressure loading method Tightness Pressure loading method Functionality (correct operation) Pressure loading method PN-G-15536:2013 p. 6.4.4, 6.4.4.4, 6.5 i/and 6.4.2.5","categories":["other"],"row_index":79,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Power hydraulics elements Fatigue resistance Pressure loading method Tightness Pressure loading method Functionality (correct operation) Pressure loading method PN-G-15536:2013 p. 6.4.4, 6.4.4.4, 6.5 i/and 6.4.2.5"},{"_id":"6a5a55ef9af9f73f38250aec","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Rozpory Mining struts","test_object_en":"Mining struts","methodology":"Wymiary liniowe Metoda pomiaru bezpośredniego Możliwość montażu przy określonym kącie Stabilność rozpory: − poprzeczna − prostopadła Metoda obciążenia siłą Wzdłużna nośność rozpory na rozciąganie Metoda obciążenia siłą Wydłużenie rozpory Metoda pomiaru przemieszczenia Wzdłużna nośność rozpory na ściskanie Metoda obciążenia siłą Skrócenie rozpory Zakres: - siła do 150 kN - robocza długość (0,5 – 1,75) m Metoda pomiaru przemieszczenia Linear dimensions Direct measurement method Specific angle mounting possibility Strut stability: − transverse − perpendicular Force method Longitudinal tensile load capacity of the strut Force method Strut lengthening Displacement measurement method Longitudinal compressive strength of the strut Force method Strut shortening Range: - force up to 150 kN - working length (0,5 – 1,75) m Displacement measurement method","methodology_en":"Linear dimensions Direct measurement method Specific angle mounting possibility Strut stability: − transverse − perpendicular Force method Longitudinal tensile load capacity of the strut Force method Strut lengthening Displacement measurement method Longitudinal compressive strength of the strut Force method Strut shortening Range: - force up to 150 kN - working length (0,5 – 1,75) m Displacement measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary liniowe Metoda pomiaru bezpośredniego Możliwość montażu przy określonym kącie Stabilność rozpory: − poprzeczna − prostopadła Metoda obciążenia siłą Wzdłużna nośność rozpory na rozciąganie Metoda obciążenia siłą Wydłużenie rozpory Metoda pomiaru przemieszczenia Wzdłużna nośność rozpory na ściskanie Metoda obciążenia siłą Skrócenie rozpory Zakres: - siła do 150 kN - robocza długość (0,5 – 1,75) m Metoda pomiaru przemieszczenia Linear dimensions Direct measurement method Specific angle mounting possibility Strut stability: − transverse − perpendicular Force method Longitudinal tensile load capacity of the strut Force method Strut lengthening Displacement measurement method Longitudinal compressive strength of the strut Force method Strut shortening Range: - force up to 150 kN - working length (0,5 – 1,75) m Displacement measurement method","reference":"PN-G-15024:2017-10","norm_bases":["PN-G-15024:2017-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozpory Mining struts Wymiary liniowe Metoda pomiaru bezpośredniego Możliwość montażu przy określonym kącie Stabilność rozpory: − poprzeczna − prostopadła Metoda obciążenia siłą Wzdłużna nośność rozpory na rozciąganie Metoda obciążenia siłą Wydłużenie rozpory Metoda pomiaru przemieszczenia Wzdłużna nośność rozpory na ściskanie Metoda obciążenia siłą Skrócenie rozpory Zakres: - siła do 150 kN - robocza długość (0,5 – 1,75) m Metoda pomiaru przemieszczenia Linear dimensions Direct measurement method Specific angle mounting possibility Strut stability: − transverse − perpendicular Force method Longitudinal tensile load capacity of the strut Force method Strut lengthening Displacement measurement method Longitudinal compressive strength of the strut Force method Strut shortening Range: - force up to 150 kN - working length (0,5 – 1,75) m Displacement measurement method PN-G-15024:2017-10 Rozpory Mining struts Wymiary liniowe Metoda pomiaru bezposredniego Mozliwosc montazu przy okreslonym kacie Stabilnosc rozpory: − poprzeczna − prostopadla Metoda obciazenia sila Wzdluzna nosnosc rozpory na rozciaganie Metoda obciazenia sila Wydluzenie rozpory Metoda pomiaru przemieszczenia Wzdluzna nosnosc rozpory na sciskanie Metoda obciazenia sila Skrocenie rozpory Zakres: - sila do 150 kN - robocza dlugosc (0,5 – 1,75) m Metoda pomiaru przemieszczenia Linear dimensions Direct measurement method Specific angle mounting possibility Strut stability: − transverse − perpendicular Force method Longitudinal tensile load capacity of the strut Force method Strut lengthening Displacement measurement method Longitudinal compressive strength of the strut Force method Strut shortening Range: - force up to 150 kN - working length (0,5 – 1,75) m Displacement measurement method PN-G-15024:2017-10","categories":["other"],"row_index":80,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mining struts Linear dimensions Direct measurement method Specific angle mounting possibility Strut stability: − transverse − perpendicular Force method Longitudinal tensile load capacity of the strut Force method Strut lengthening Displacement measurement method Longitudinal compressive strength of the strut Force method Strut shortening Range: - force up to 150 kN - working length (0,5 – 1,75) m Displacement measurement method PN-G-15024:2017-10"},{"_id":"6a5a55ef9af9f73f38250aed","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Strzemiona oraz złącza odrzwi z kształtowników korytkowych","test_object_en":"Stirrups and joints of arch supports made of trough sections","methodology":"Metoda pomiaru bezpośredniego Charakterystyka pracy Średnia nośność zsuwna złącza Zakres: - siła do 3000 kN - przemieszczenie do 0,35 mm Metoda obciążenia siłą z pomiarem przemieszczenia Metoda pomiaru bezpośredniego Statyczna próba zginania złącza Zakres: - siła do 3000 kN - przemieszczenie do 0,35 m Metoda obciążenia siłą z pomiarem przemieszczenia Wymiary liniowe Metoda pomiaru bezpośredniego Wytrzymałość na obciążenie próbne i maksymalne jarzm strzemion Zakres: Siła do 3000 kN Strzałka ugięcia 0,5 m Metoda obciążenia siłą z pomiarem przemieszczenia Wymiary liniowe Metoda pomiaru bezpośredniego Wytrzymałość na obciążenie próbne śrub pełnowymiarowych, nakrętek i śrub hakowych Zakres: Siła do 1000 kN Strzałka ugięcia 0,5 m Metoda obciążenia siłą z pomiarem przemieszczenia","methodology_en":"Direct measurement method Operating characteristics Average sliding load capacity of the joint Range: - force up to 3000 kN - displacement up to 0,35 mm Force loading method with displacement measurement Direct measurement method Static bending test of the joint Range: - force up to 3000 kN - displacement up to 0,35 m Force loading method with displacement measurement Linear dimensions Direct measurement method Strength at proof and maximum load of stirrup yokes Range: Force up to 3000 kN Deflection 0,5 m Force loading method with displacement measurement Linear dimensions Direct measurement method Strength at proof load of full-size bolts, nuts and hook bolts Range: Force up to 1000 kN Deflection 0,5 m Force loading method with displacement measurement","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Metoda pomiaru bezpośredniego Charakterystyka pracy Średnia nośność zsuwna złącza Zakres: - siła do 3000 kN - przemieszczenie do 0,35 mm Metoda obciążenia siłą z pomiarem przemieszczenia Metoda pomiaru bezpośredniego Statyczna próba zginania złącza Zakres: - siła do 3000 kN - przemieszczenie do 0,35 m Metoda obciążenia siłą z pomiarem przemieszczenia Wymiary liniowe Metoda pomiaru bezpośredniego Wytrzymałość na obciążenie próbne i maksymalne jarzm strzemion Zakres: Siła do 3000 kN Strzałka ugięcia 0,5 m Metoda obciążenia siłą z pomiarem przemieszczenia Wymiary liniowe Metoda pomiaru bezpośredniego Wytrzymałość na obciążenie próbne śrub pełnowymiarowych, nakrętek i śrub hakowych Zakres: Siła do 1000 kN Strzałka ugięcia 0,5 m Metoda obciążenia siłą z pomiarem przemieszczenia","reference":"PN-G-15026:2017-04 DIN 21530-4:2003 p. 4.1.2.2.2 i/and 4.1.2.2.3 PN-EN ISO 898-1 PN-EN ISO 898-2","norm_bases":["PN-G-15026:2017-04 DIN 21530-4:2003 p. 4.1.2.2.2 i/and 4.1.2.2.3 PN-EN ISO 898-1 PN-EN ISO 898-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Strzemiona oraz złącza odrzwi z kształtowników korytkowych Metoda pomiaru bezpośredniego Charakterystyka pracy Średnia nośność zsuwna złącza Zakres: - siła do 3000 kN - przemieszczenie do 0,35 mm Metoda obciążenia siłą z pomiarem przemieszczenia Metoda pomiaru bezpośredniego Statyczna próba zginania złącza Zakres: - siła do 3000 kN - przemieszczenie do 0,35 m Metoda obciążenia siłą z pomiarem przemieszczenia Wymiary liniowe Metoda pomiaru bezpośredniego Wytrzymałość na obciążenie próbne i maksymalne jarzm strzemion Zakres: Siła do 3000 kN Strzałka ugięcia 0,5 m Metoda obciążenia siłą z pomiarem przemieszczenia Wymiary liniowe Metoda pomiaru bezpośredniego Wytrzymałość na obciążenie próbne śrub pełnowymiarowych, nakrętek i śrub hakowych Zakres: Siła do 1000 kN Strzałka ugięcia 0,5 m Metoda obciążenia siłą z pomiarem przemieszczenia PN-G-15026:2017-04 DIN 21530-4:2003 p. 4.1.2.2.2 i/and 4.1.2.2.3 PN-EN ISO 898-1 PN-EN ISO 898-2 Strzemiona oraz zlacza odrzwi z ksztaltownikow korytkowych Metoda pomiaru bezposredniego Charakterystyka pracy Srednia nosnosc zsuwna zlacza Zakres: - sila do 3000 kN - przemieszczenie do 0,35 mm Metoda obciazenia sila z pomiarem przemieszczenia Metoda pomiaru bezposredniego Statyczna proba zginania zlacza Zakres: - sila do 3000 kN - przemieszczenie do 0,35 m Metoda obciazenia sila z pomiarem przemieszczenia Wymiary liniowe Metoda pomiaru bezposredniego Wytrzymalosc na obciazenie probne i maksymalne jarzm strzemion Zakres: Sila do 3000 kN Strzalka ugiecia 0,5 m Metoda obciazenia sila z pomiarem przemieszczenia Wymiary liniowe Metoda pomiaru bezposredniego Wytrzymalosc na obciazenie probne srub pelnowymiarowych, nakretek i srub hakowych Zakres: Sila do 1000 kN Strzalka ugiecia 0,5 m Metoda obciazenia sila z pomiarem przemieszczenia PN-G-15026:2017-04 DIN 21530-4:2003 p. 4.1.2.2.2 i/and 4.1.2.2.3 PN-EN ISO 898-1 PN-EN ISO 898-2","categories":["other"],"row_index":81,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Stirrups and joints of arch supports made of trough sections Direct measurement method Operating characteristics Average sliding load capacity of the joint Range: - force up to 3000 kN - displacement up to 0,35 mm Force loading method with displacement measurement Direct measurement method Static bending test of the joint Range: - force up to 3000 kN - displacement up to 0,35 m Force loading method with displacement measurement Linear dimensions Direct measurement method Strength at proof and maximum load of stirrup yokes Range: Force up to 3000 kN Deflection 0,5 m Force loading method with displacement measurement Linear dimensions Direct measurement method Strength at proof load of full-size bolts, nuts and hook bolts Range: Force up to 1000 kN Deflection 0,5 m Force loading method with displacement measurement PN-G-15026:2017-04 DIN 21530-4:2003 p. 4.1.2.2.2 i/and 4.1.2.2.3 PN-EN ISO 898-1 PN-EN ISO 898-2"},{"_id":"6a5a55ef9af9f73f38250aee","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Steel arch support clamps and joints","test_object_en":"Steel arch support clamps and joints","methodology":"Direct measurement method Work characteristics Average sliding load capacity of the joint Range: - force up to 3000 kN - displacement up to 0,35 mm Force method with displacement measurement Direct measurement method Static bend test of the joint Range: - force up to 3000 kN - displacement up to 0,35 m Force method with displacement measurement Linear dimensions Direct measurement method Resistance to proof load and maximum load of the clamp joint Range: Force up to 3000 kN Deflection value 0,5 m Force method with displacement measurement Linear dimensions Direct measurement method Resistance to proof load of the full size bolts, nuts and hook bolts Range: Force up to 1000 kN Deflection value 0,5 m Force method with displacement measurement","methodology_en":"Direct measurement method Work characteristics Average sliding load capacity of the joint Range: - force up to 3000 kN - displacement up to 0,35 mm Force method with displacement measurement Direct measurement method Static bend test of the joint Range: - force up to 3000 kN - displacement up to 0,35 m Force method with displacement measurement Linear dimensions Direct measurement method Resistance to proof load and maximum load of the clamp joint Range: Force up to 3000 kN Deflection value 0,5 m Force method with displacement measurement Linear dimensions Direct measurement method Resistance to proof load of the full size bolts, nuts and hook bolts Range: Force up to 1000 kN Deflection value 0,5 m Force method with displacement measurement","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Direct measurement method Work characteristics Average sliding load capacity of the joint Range: - force up to 3000 kN - displacement up to 0,35 mm Force method with displacement measurement Direct measurement method Static bend test of the joint Range: - force up to 3000 kN - displacement up to 0,35 m Force method with displacement measurement Linear dimensions Direct measurement method Resistance to proof load and maximum load of the clamp joint Range: Force up to 3000 kN Deflection value 0,5 m Force method with displacement measurement Linear dimensions Direct measurement method Resistance to proof load of the full size bolts, nuts and hook bolts Range: Force up to 1000 kN Deflection value 0,5 m Force method with displacement measurement","reference":"PN-G-15026:2017-04 DIN 21530-4:2003 p. 4.1.2.2.2 i/and 4.1.2.2.3 PN-EN ISO 898-1 PN-EN ISO 898-2","norm_bases":["PN-G-15026:2017-04 DIN 21530-4:2003 p. 4.1.2.2.2 i/and 4.1.2.2.3 PN-EN ISO 898-1 PN-EN ISO 898-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Steel arch support clamps and joints Direct measurement method Work characteristics Average sliding load capacity of the joint Range: - force up to 3000 kN - displacement up to 0,35 mm Force method with displacement measurement Direct measurement method Static bend test of the joint Range: - force up to 3000 kN - displacement up to 0,35 m Force method with displacement measurement Linear dimensions Direct measurement method Resistance to proof load and maximum load of the clamp joint Range: Force up to 3000 kN Deflection value 0,5 m Force method with displacement measurement Linear dimensions Direct measurement method Resistance to proof load of the full size bolts, nuts and hook bolts Range: Force up to 1000 kN Deflection value 0,5 m Force method with displacement measurement PN-G-15026:2017-04 DIN 21530-4:2003 p. 4.1.2.2.2 i/and 4.1.2.2.3 PN-EN ISO 898-1 PN-EN ISO 898-2 Steel arch support clamps and joints Direct measurement method Work characteristics Average sliding load capacity of the joint Range: - force up to 3000 kN - displacement up to 0,35 mm Force method with displacement measurement Direct measurement method Static bend test of the joint Range: - force up to 3000 kN - displacement up to 0,35 m Force method with displacement measurement Linear dimensions Direct measurement method Resistance to proof load and maximum load of the clamp joint Range: Force up to 3000 kN Deflection value 0,5 m Force method with displacement measurement Linear dimensions Direct measurement method Resistance to proof load of the full size bolts, nuts and hook bolts Range: Force up to 1000 kN Deflection value 0,5 m Force method with displacement measurement PN-G-15026:2017-04 DIN 21530-4:2003 p. 4.1.2.2.2 i/and 4.1.2.2.3 PN-EN ISO 898-1 PN-EN ISO 898-2","categories":["materials"],"row_index":82,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Steel arch support clamps and joints Direct measurement method Work characteristics Average sliding load capacity of the joint Range: - force up to 3000 kN - displacement up to 0,35 mm Force method with displacement measurement Direct measurement method Static bend test of the joint Range: - force up to 3000 kN - displacement up to 0,35 m Force method with displacement measurement Linear dimensions Direct measurement method Resistance to proof load and maximum load of the clamp joint Range: Force up to 3000 kN Deflection value 0,5 m Force method with displacement measurement Linear dimensions Direct measurement method Resistance to proof load of the full size bolts, nuts and hook bolts Range: Force up to 1000 kN Deflection value 0,5 m Force method with displacement measurement PN-G-15026:2017-04 DIN 21530-4:2003 p. 4.1.2.2.2 i/and 4.1.2.2.3 PN-EN ISO 898-1 PN-EN ISO 898-2"},{"_id":"6a5a55ef9af9f73f38250aef","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"PCA","test_object_en":"PCA","methodology":"Zakres akredytacji Nr AB 005","methodology_en":"Scope of accreditation No. AB 005","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zakres akredytacji Nr AB 005","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"PCA Zakres akredytacji Nr AB 005 PCA Zakres akredytacji Nr AB 005","categories":["other"],"row_index":83,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"PCA Scope of accreditation No. AB 005","search_zh":"PCA","test_object_zh":"PCA"},{"_id":"6a5a55ef9af9f73f38250af0","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"PCA","test_object_en":"PCA","methodology":"Scope of accreditation No. AB 005","methodology_en":"Scope of accreditation No. AB 005","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Scope of accreditation No. AB 005","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"PCA Scope of accreditation No. AB 005 PCA Scope of accreditation No. AB 005","categories":["other"],"row_index":84,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"PCA Scope of accreditation No. AB 005","search_zh":"PCA","test_object_zh":"PCA"},{"_id":"6a5a55ef9af9f73f38250af1","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Kotwie górnicze Mining bolts/anchors, micropiles","test_object_en":"Mining bolts/anchors, micropiles","methodology":"Nośność żerdzi z elementam","methodology_en":"Nośność żerdzi z elementam","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność żerdzi z elementam","reference":"Procedura BL-2/ZLGIG/PB-EK 01 edycja 3 z dnia 25.08.2023 r. Procedure BL-2/ZLGIG/PB-EK 01 3rd edition of 25 August 2023","norm_bases":["Procedura BL-2/ZLGIG/PB-EK 01 edycja 3 z dnia 25.08.2023 r. Procedure BL-2/ZLGIG/PB-EK 01 3rd edition of 25 August 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kotwie górnicze Mining bolts/anchors, micropiles Nośność żerdzi z elementam Procedura BL-2/ZLGIG/PB-EK 01 edycja 3 z dnia 25.08.2023 r. Procedure BL-2/ZLGIG/PB-EK 01 3rd edition of 25 August 2023 Kotwie gornicze Mining bolts/anchors, micropiles Nosnosc zerdzi z elementam Procedura BL-2/ZLGIG/PB-EK 01 edycja 3 z dnia 25.08.2023 r. Procedure BL-2/ZLGIG/PB-EK 01 3rd edition of 25 August 2023","categories":["other"],"row_index":85,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mining bolts/anchors, micropiles Nośność żerdzi z elementam Procedura BL-2/ZLGIG/PB-EK 01 edycja 3 z dnia 25.08.2023 r. Procedure BL-2/ZLGIG/PB-EK 01 3rd edition of 25 August 2023","search_zh":"矿用锚杆 Mining bolts/anchors, micropiles Procedura BL-2/ZLGIG/PB-EK 01 edycja 3 z dnia 25.08.2023 r. Procedure BL-2/ZLGIG/PB-EK 01 3rd edition of 25 August 2023","test_object_zh":"矿用锚杆 Mining bolts/anchors, micropiles"},{"_id":"6a5a55ef9af9f73f38250af2","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Kotwie górnicze Mining bolts/anchors, micropiles","test_object_en":"Mining bolts/anchors, micropiles","methodology":"mocującymi","methodology_en":"fixing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"mocującymi","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kotwie górnicze Mining bolts/anchors, micropiles mocującymi Kotwie gornicze Mining bolts/anchors, micropiles mocujacymi","categories":["other"],"row_index":86,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mining bolts/anchors, micropiles fixing","search_zh":"矿用锚杆 Mining bolts/anchors, micropiles","test_object_zh":"矿用锚杆 Mining bolts/anchors, micropiles"},{"_id":"6a5a55ef9af9f73f38250af3","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Kotwie górnicze Mining bolts/anchors, micropiles","test_object_en":"Mining bolts/anchors, micropiles","methodology":"Zakres: siła do 5000 kN","methodology_en":"Range: force up to 5000 kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zakres: siła do 5000 kN","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kotwie górnicze Mining bolts/anchors, micropiles Zakres: siła do 5000 kN Kotwie gornicze Mining bolts/anchors, micropiles Zakres: sila do 5000 kN","categories":["other"],"row_index":87,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mining bolts/anchors, micropiles Range: force up to 5000 kN","search_zh":"矿用锚杆 Mining bolts/anchors, micropiles","test_object_zh":"矿用锚杆 Mining bolts/anchors, micropiles"},{"_id":"6a5a55ef9af9f73f38250af4","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odrzwia obudowy chodnikowej","test_object_en":"Roadway support frames","methodology":"Wymiary liniowe Zakres: - wysokość odrzwi do 4,7 m - szerokość odrzwi do 7,0 m Metoda pomiaru bezpośredniego Maksymalna nośność odrzwi Zakres: - siła do 7500 kN Metoda obciążenia siłą Robocza nośność odrzwi Zakres: - siła do 7500 kN Metoda obciążenia siłą Początkowa nośność odrzwi Końcowa nośność odrzwi Minimalna nośność odrzwi Zakres: - siła do 7500 kN Metoda obciążenia siłą Całkowite zmniejszenie wysokości odrzwi Zakres: - wysokość odrzwi do 4,7 m Metoda pomiaru bezpośredniego Pomiar kąta Zakres 0÷90 Pomiar bezpośredni Masa elementów odrzwi Zakres: - do 5000 kg Metoda pomiaru bezpośredniego Liczba zsuwów Metoda pomiaru bezpośredniego Długość zsuwów w poszczególnych złączach do 5 m Metoda pomiaru bezpośredniego Wskaźnik maksymalnej nośności odrzwi na jednostkę masy k 1 Wskaźnik roboczej nośności odrzwi na jednostkę masy k2 Stopień wykorzystania maksymalnej nośności odrzwi k 3","methodology_en":"Linear dimensions Range: - height of the support set up to 4,7 m - width of the support set up to 7,0 m Direct measurement method Maximum load capacity of the support set Range: - force up to 7500 kN Force loading method Working load capacity of the support set Range: - force up to 7500 kN Force loading method Initial load capacity of the support set Final load capacity of the support set Minimum load capacity of the support set Range: - force up to 7500 kN Force loading method Total reduction of the support set height Range: - height of the support set up to 4,7 m Direct measurement method Angle measurement Range 0÷90 Direct measurement Mass of the support set components Range: - up to 5000 kg Direct measurement method Number of slips Direct measurement method Length of slips in individual joints up to 5 m Direct measurement method Index of the maximum load capacity of the support set per unit mass k 1 Index of the working load capacity of the support set per unit mass k2 Degree of utilisation of the maximum load capacity of the support set k 3","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary liniowe Zakres: - wysokość odrzwi do 4,7 m - szerokość odrzwi do 7,0 m Metoda pomiaru bezpośredniego Maksymalna nośność odrzwi Zakres: - siła do 7500 kN Metoda obciążenia siłą Robocza nośność odrzwi Zakres: - siła do 7500 kN Metoda obciążenia siłą Początkowa nośność odrzwi Końcowa nośność odrzwi Minimalna nośność odrzwi Zakres: - siła do 7500 kN Metoda obciążenia siłą Całkowite zmniejszenie wysokości odrzwi Zakres: - wysokość odrzwi do 4,7 m Metoda pomiaru bezpośredniego Pomiar kąta Zakres 0÷90 Pomiar bezpośredni Masa elementów odrzwi Zakres: - do 5000 kg Metoda pomiaru bezpośredniego Liczba zsuwów Metoda pomiaru bezpośredniego Długość zsuwów w poszczególnych złączach do 5 m Metoda pomiaru bezpośredniego Wskaźnik maksymalnej nośności odrzwi na jednostkę masy k 1 Wskaźnik roboczej nośności odrzwi na jednostkę masy k2 Stopień wykorzystania maksymalnej nośności odrzwi k 3","reference":"PN-G-15022:2018-11","norm_bases":["PN-G-15022:2018-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odrzwia obudowy chodnikowej Wymiary liniowe Zakres: - wysokość odrzwi do 4,7 m - szerokość odrzwi do 7,0 m Metoda pomiaru bezpośredniego Maksymalna nośność odrzwi Zakres: - siła do 7500 kN Metoda obciążenia siłą Robocza nośność odrzwi Zakres: - siła do 7500 kN Metoda obciążenia siłą Początkowa nośność odrzwi Końcowa nośność odrzwi Minimalna nośność odrzwi Zakres: - siła do 7500 kN Metoda obciążenia siłą Całkowite zmniejszenie wysokości odrzwi Zakres: - wysokość odrzwi do 4,7 m Metoda pomiaru bezpośredniego Pomiar kąta Zakres 0÷90 Pomiar bezpośredni Masa elementów odrzwi Zakres: - do 5000 kg Metoda pomiaru bezpośredniego Liczba zsuwów Metoda pomiaru bezpośredniego Długość zsuwów w poszczególnych złączach do 5 m Metoda pomiaru bezpośredniego Wskaźnik maksymalnej nośności odrzwi na jednostkę masy k 1 Wskaźnik roboczej nośności odrzwi na jednostkę masy k2 Stopień wykorzystania maksymalnej nośności odrzwi k 3 PN-G-15022:2018-11 Odrzwia obudowy chodnikowej Wymiary liniowe Zakres: - wysokosc odrzwi do 4,7 m - szerokosc odrzwi do 7,0 m Metoda pomiaru bezposredniego Maksymalna nosnosc odrzwi Zakres: - sila do 7500 kN Metoda obciazenia sila Robocza nosnosc odrzwi Zakres: - sila do 7500 kN Metoda obciazenia sila Poczatkowa nosnosc odrzwi Koncowa nosnosc odrzwi Minimalna nosnosc odrzwi Zakres: - sila do 7500 kN Metoda obciazenia sila Calkowite zmniejszenie wysokosci odrzwi Zakres: - wysokosc odrzwi do 4,7 m Metoda pomiaru bezposredniego Pomiar kata Zakres 0÷90 Pomiar bezposredni Masa elementow odrzwi Zakres: - do 5000 kg Metoda pomiaru bezposredniego Liczba zsuwow Metoda pomiaru bezposredniego Dlugosc zsuwow w poszczegolnych zlaczach do 5 m Metoda pomiaru bezposredniego Wskaznik maksymalnej nosnosci odrzwi na jednostke masy k 1 Wskaznik roboczej nosnosci odrzwi na jednostke masy k2 Stopien wykorzystania maksymalnej nosnosci odrzwi k 3 PN-G-15022:2018-11","categories":["other"],"row_index":88,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Roadway support frames Linear dimensions Range: - height of the support set up to 4,7 m - width of the support set up to 7,0 m Direct measurement method Maximum load capacity of the support set Range: - force up to 7500 kN Force loading method Working load capacity of the support set Range: - force up to 7500 kN Force loading method Initial load capacity of the support set Final load capacity of the support set Minimum load capacity of the support set Range: - force up to 7500 kN Force loading method Total reduction of the support set height Range: - height of the support set up to 4,7 m Direct measurement method Angle measurement Range 0÷90 Direct measurement Mass of the support set components Range: - up to 5000 kg Direct measurement method Number of slips Direct measurement method Length of slips in individual joints up to 5 m Direct measurement method Index of the maximum load capacity of the support set per unit mass k 1 Index of the working load capacity of the support set per unit mass k2 Degree of utilisation of the maximum load capacity of the support set k 3 PN-G-15022:2018-11"},{"_id":"6a5a55ef9af9f73f38250af5","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Gallery working support","test_object_en":"Gallery working support","methodology":"Linear dimensions Range: - support height up to 4,7 m - support width up to 7,0 m Direct measurement method Maximum load capacity of the support Range: - force up to 7500 kN Force method Working load capacity of the support Range: - force up to 7500 kN Force method Initial bearing capacity of the support Final bearing capacity of the support Minimal bearing capacity of the support Range: - force up to 7500 kN Force method Complete reduction of the support height Range: - height support up to 4,7 m Direct measurement method Angle measurement Range 0÷90 Direct measurement Mass of support elements Range: - up to 5000 kg Direct measurement method Number of slides Direct measurement method Length of slides in every joint up to 5 m Direct measurement method Index of the maximum load capacity of the support per unit mass k 1 Index of the working load capacity of the support per unit mass k 2 Degree of utilization of the maximum load capacity of the support k 3","methodology_en":"Linear dimensions Range: - support height up to 4,7 m - support width up to 7,0 m Direct measurement method Maximum load capacity of the support Range: - force up to 7500 kN Force method Working load capacity of the support Range: - force up to 7500 kN Force method Initial bearing capacity of the support Final bearing capacity of the support Minimal bearing capacity of the support Range: - force up to 7500 kN Force method Complete reduction of the support height Range: - height support up to 4,7 m Direct measurement method Angle measurement Range 0÷90 Direct measurement Mass of support elements Range: - up to 5000 kg Direct measurement method Number of slides Direct measurement method Length of slides in every joint up to 5 m Direct measurement method Index of the maximum load capacity of the support per unit mass k 1 Index of the working load capacity of the support per unit mass k 2 Degree of utilization of the maximum load capacity of the support k 3","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Linear dimensions Range: - support height up to 4,7 m - support width up to 7,0 m Direct measurement method Maximum load capacity of the support Range: - force up to 7500 kN Force method Working load capacity of the support Range: - force up to 7500 kN Force method Initial bearing capacity of the support Final bearing capacity of the support Minimal bearing capacity of the support Range: - force up to 7500 kN Force method Complete reduction of the support height Range: - height support up to 4,7 m Direct measurement method Angle measurement Range 0÷90 Direct measurement Mass of support elements Range: - up to 5000 kg Direct measurement method Number of slides Direct measurement method Length of slides in every joint up to 5 m Direct measurement method Index of the maximum load capacity of the support per unit mass k 1 Index of the working load capacity of the support per unit mass k 2 Degree of utilization of the maximum load capacity of the support k 3","reference":"PN-G-15022:2018-11","norm_bases":["PN-G-15022:2018-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gallery working support Linear dimensions Range: - support height up to 4,7 m - support width up to 7,0 m Direct measurement method Maximum load capacity of the support Range: - force up to 7500 kN Force method Working load capacity of the support Range: - force up to 7500 kN Force method Initial bearing capacity of the support Final bearing capacity of the support Minimal bearing capacity of the support Range: - force up to 7500 kN Force method Complete reduction of the support height Range: - height support up to 4,7 m Direct measurement method Angle measurement Range 0÷90 Direct measurement Mass of support elements Range: - up to 5000 kg Direct measurement method Number of slides Direct measurement method Length of slides in every joint up to 5 m Direct measurement method Index of the maximum load capacity of the support per unit mass k 1 Index of the working load capacity of the support per unit mass k 2 Degree of utilization of the maximum load capacity of the support k 3 PN-G-15022:2018-11 Gallery working support Linear dimensions Range: - support height up to 4,7 m - support width up to 7,0 m Direct measurement method Maximum load capacity of the support Range: - force up to 7500 kN Force method Working load capacity of the support Range: - force up to 7500 kN Force method Initial bearing capacity of the support Final bearing capacity of the support Minimal bearing capacity of the support Range: - force up to 7500 kN Force method Complete reduction of the support height Range: - height support up to 4,7 m Direct measurement method Angle measurement Range 0÷90 Direct measurement Mass of support elements Range: - up to 5000 kg Direct measurement method Number of slides Direct measurement method Length of slides in every joint up to 5 m Direct measurement method Index of the maximum load capacity of the support per unit mass k 1 Index of the working load capacity of the support per unit mass k 2 Degree of utilization of the maximum load capacity of the support k 3 PN-G-15022:2018-11","categories":["other"],"row_index":89,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gallery working support Linear dimensions Range: - support height up to 4,7 m - support width up to 7,0 m Direct measurement method Maximum load capacity of the support Range: - force up to 7500 kN Force method Working load capacity of the support Range: - force up to 7500 kN Force method Initial bearing capacity of the support Final bearing capacity of the support Minimal bearing capacity of the support Range: - force up to 7500 kN Force method Complete reduction of the support height Range: - height support up to 4,7 m Direct measurement method Angle measurement Range 0÷90 Direct measurement Mass of support elements Range: - up to 5000 kg Direct measurement method Number of slides Direct measurement method Length of slides in every joint up to 5 m Direct measurement method Index of the maximum load capacity of the support per unit mass k 1 Index of the working load capacity of the support per unit mass k 2 Degree of utilization of the maximum load capacity of the support k 3 PN-G-15022:2018-11"},{"_id":"6a5a55ef9af9f73f38250af6","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Hydrauliczne przewody giętkie Flexible rubber hoses","test_object_en":"Flexible rubber hoses","methodology":"Wymiary liniowe Metoda pomiaru bezpośredniego Wytrzymałość na ciśnienie próbne Zakres: - ciśnienie do 200 MPa Metoda obciążenia ciśnieniem Wytrzymałość na ciśnienie rozrywające Zakres: - ciśnienie do 200 MPa Metoda obciążenia ciśnieniem Linear dimensions Direct measurement method Test pressure resistance Range: - pressure up to 200 MPa Pressure loading method Burst pressure resistance Range: - pressure up to 200 MPa Pressure loading method","methodology_en":"Linear dimensions Direct measurement method Test pressure resistance Range: - pressure up to 200 MPa Pressure loading method Burst pressure resistance Range: - pressure up to 200 MPa Pressure loading method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary liniowe Metoda pomiaru bezpośredniego Wytrzymałość na ciśnienie próbne Zakres: - ciśnienie do 200 MPa Metoda obciążenia ciśnieniem Wytrzymałość na ciśnienie rozrywające Zakres: - ciśnienie do 200 MPa Metoda obciążenia ciśnieniem Linear dimensions Direct measurement method Test pressure resistance Range: - pressure up to 200 MPa Pressure loading method Burst pressure resistance Range: - pressure up to 200 MPa Pressure loading method","reference":"PN-EN ISO 4671:2008 p. 10 PN-EN ISO1402:2010 p. 8.1","norm_bases":["PN-EN ISO 4671:2008 p. 10 PN-EN ISO1402:2010 p. 8.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Hydrauliczne przewody giętkie Flexible rubber hoses Wymiary liniowe Metoda pomiaru bezpośredniego Wytrzymałość na ciśnienie próbne Zakres: - ciśnienie do 200 MPa Metoda obciążenia ciśnieniem Wytrzymałość na ciśnienie rozrywające Zakres: - ciśnienie do 200 MPa Metoda obciążenia ciśnieniem Linear dimensions Direct measurement method Test pressure resistance Range: - pressure up to 200 MPa Pressure loading method Burst pressure resistance Range: - pressure up to 200 MPa Pressure loading method PN-EN ISO 4671:2008 p. 10 PN-EN ISO1402:2010 p. 8.1 Hydrauliczne przewody gietkie Flexible rubber hoses Wymiary liniowe Metoda pomiaru bezposredniego Wytrzymalosc na cisnienie probne Zakres: - cisnienie do 200 MPa Metoda obciazenia cisnieniem Wytrzymalosc na cisnienie rozrywajace Zakres: - cisnienie do 200 MPa Metoda obciazenia cisnieniem Linear dimensions Direct measurement method Test pressure resistance Range: - pressure up to 200 MPa Pressure loading method Burst pressure resistance Range: - pressure up to 200 MPa Pressure loading method PN-EN ISO 4671:2008 p. 10 PN-EN ISO1402:2010 p. 8.1","categories":["materials"],"row_index":90,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Flexible rubber hoses Linear dimensions Direct measurement method Test pressure resistance Range: - pressure up to 200 MPa Pressure loading method Burst pressure resistance Range: - pressure up to 200 MPa Pressure loading method PN-EN ISO 4671:2008 p. 10 PN-EN ISO1402:2010 p. 8.1"},{"_id":"6a5a55ef9af9f73f38250af7","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Węże gumowe tłoczne Delivery rubber hoses","test_object_en":"Delivery rubber hoses","methodology":"Wymiary liniowe Metoda pomiaru bezpośredniego Wytrzymałość na ciśnienie próbne Zakres: - ciśnienie do 200 MPa Metoda obciążenia ciśnieniem Wytrzymałość na ciśnienie rozrywające Zakres: - ciśnienie do 200 MPa Metoda obciążenia ciśnieniem Zmiana długości pod wpływem ciśnienia Zakres: - ciśnienie do 200 MPa Metoda obciążenia ciśnieniem Linear dimensions Direct measurement method Test pressure resistance Range: - pressure up to 200 MPa Pressure loading method Burst pressure resistance Range: - pressure up to 200 MPa Pressure loading method Length change under pressure Range: - pressure up to 200 MPa Pressure loading method","methodology_en":"Linear dimensions Direct measurement method Test pressure resistance Range: - pressure up to 200 MPa Pressure loading method Burst pressure resistance Range: - pressure up to 200 MPa Pressure loading method Length change under pressure Range: - pressure up to 200 MPa Pressure loading method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary liniowe Metoda pomiaru bezpośredniego Wytrzymałość na ciśnienie próbne Zakres: - ciśnienie do 200 MPa Metoda obciążenia ciśnieniem Wytrzymałość na ciśnienie rozrywające Zakres: - ciśnienie do 200 MPa Metoda obciążenia ciśnieniem Zmiana długości pod wpływem ciśnienia Zakres: - ciśnienie do 200 MPa Metoda obciążenia ciśnieniem Linear dimensions Direct measurement method Test pressure resistance Range: - pressure up to 200 MPa Pressure loading method Burst pressure resistance Range: - pressure up to 200 MPa Pressure loading method Length change under pressure Range: - pressure up to 200 MPa Pressure loading method","reference":"PN-EN ISO 4671:2008 p. 10 PN-EN ISO1402:2010 p. 8.1","norm_bases":["PN-EN ISO 4671:2008 p. 10 PN-EN ISO1402:2010 p. 8.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Węże gumowe tłoczne Delivery rubber hoses Wymiary liniowe Metoda pomiaru bezpośredniego Wytrzymałość na ciśnienie próbne Zakres: - ciśnienie do 200 MPa Metoda obciążenia ciśnieniem Wytrzymałość na ciśnienie rozrywające Zakres: - ciśnienie do 200 MPa Metoda obciążenia ciśnieniem Zmiana długości pod wpływem ciśnienia Zakres: - ciśnienie do 200 MPa Metoda obciążenia ciśnieniem Linear dimensions Direct measurement method Test pressure resistance Range: - pressure up to 200 MPa Pressure loading method Burst pressure resistance Range: - pressure up to 200 MPa Pressure loading method Length change under pressure Range: - pressure up to 200 MPa Pressure loading method PN-EN ISO 4671:2008 p. 10 PN-EN ISO1402:2010 p. 8.1 Weze gumowe tloczne Delivery rubber hoses Wymiary liniowe Metoda pomiaru bezposredniego Wytrzymalosc na cisnienie probne Zakres: - cisnienie do 200 MPa Metoda obciazenia cisnieniem Wytrzymalosc na cisnienie rozrywajace Zakres: - cisnienie do 200 MPa Metoda obciazenia cisnieniem Zmiana dlugosci pod wplywem cisnienia Zakres: - cisnienie do 200 MPa Metoda obciazenia cisnieniem Linear dimensions Direct measurement method Test pressure resistance Range: - pressure up to 200 MPa Pressure loading method Burst pressure resistance Range: - pressure up to 200 MPa Pressure loading method Length change under pressure Range: - pressure up to 200 MPa Pressure loading method PN-EN ISO 4671:2008 p. 10 PN-EN ISO1402:2010 p. 8.1","categories":["materials"],"row_index":91,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Delivery rubber hoses Linear dimensions Direct measurement method Test pressure resistance Range: - pressure up to 200 MPa Pressure loading method Burst pressure resistance Range: - pressure up to 200 MPa Pressure loading method Length change under pressure Range: - pressure up to 200 MPa Pressure loading method PN-EN ISO 4671:2008 p. 10 PN-EN ISO1402:2010 p. 8.1"},{"_id":"6a5a55ef9af9f73f38250af8","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Hydrauliczne elementy sterujące Hydraulic controls","test_object_en":"Hydraulic controls","methodology":"Szczelność przy ciśnieniu Zakres: - do 200 MPa Metoda obciążenia ciśnieniem Ciśnienie otwarcia i zamknięcia zaworu Zakres: - do 200 MPa Metoda obciążenia ciśnieniem Odporność na ciśnienie Zakres: - do 200 MPa Metoda obciążenia ciśnieniem Odporność na impuls ciśnienia Zakres: - do 300 MPa Metoda obciążenia ciśnieniem Wytrzymałość zmęczeniowa Zakres: - do 70 MPa Metoda obciążenia ciśnieniem Przepustowość Zakres: - do 80 l/min Metoda pomiaru przepływu Tightness under pressure Range: - up to 200 MPa Pressure loading method Valve opening and closing pressure Range: - up to 200 MPa Pressure loading method Pressure resistance Range: - up to 200 MPa Pressure loading method Pressure impulse resistance Range: - up to 300 MPa Pressure loading method Fatigue strength Range: - up to 70 MPa Pressure loading method Capacity Range: - up to 80 l/min Flow measurement method","methodology_en":"Tightness under pressure Range: - up to 200 MPa Pressure loading method Valve opening and closing pressure Range: - up to 200 MPa Pressure loading method Pressure resistance Range: - up to 200 MPa Pressure loading method Pressure impulse resistance Range: - up to 300 MPa Pressure loading method Fatigue strength Range: - up to 70 MPa Pressure loading method Capacity Range: - up to 80 l/min Flow measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność przy ciśnieniu Zakres: - do 200 MPa Metoda obciążenia ciśnieniem Ciśnienie otwarcia i zamknięcia zaworu Zakres: - do 200 MPa Metoda obciążenia ciśnieniem Odporność na ciśnienie Zakres: - do 200 MPa Metoda obciążenia ciśnieniem Odporność na impuls ciśnienia Zakres: - do 300 MPa Metoda obciążenia ciśnieniem Wytrzymałość zmęczeniowa Zakres: - do 70 MPa Metoda obciążenia ciśnieniem Przepustowość Zakres: - do 80 l/min Metoda pomiaru przepływu Tightness under pressure Range: - up to 200 MPa Pressure loading method Valve opening and closing pressure Range: - up to 200 MPa Pressure loading method Pressure resistance Range: - up to 200 MPa Pressure loading method Pressure impulse resistance Range: - up to 300 MPa Pressure loading method Fatigue strength Range: - up to 70 MPa Pressure loading method Capacity Range: - up to 80 l/min Flow measurement method","reference":"PN-EN 1804-3:2021-06 (załącznik normatywny A) / (normative annex A)","norm_bases":["PN-EN 1804-3:2021-06 (załącznik normatywny A) / (normative annex A)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Hydrauliczne elementy sterujące Hydraulic controls Szczelność przy ciśnieniu Zakres: - do 200 MPa Metoda obciążenia ciśnieniem Ciśnienie otwarcia i zamknięcia zaworu Zakres: - do 200 MPa Metoda obciążenia ciśnieniem Odporność na ciśnienie Zakres: - do 200 MPa Metoda obciążenia ciśnieniem Odporność na impuls ciśnienia Zakres: - do 300 MPa Metoda obciążenia ciśnieniem Wytrzymałość zmęczeniowa Zakres: - do 70 MPa Metoda obciążenia ciśnieniem Przepustowość Zakres: - do 80 l/min Metoda pomiaru przepływu Tightness under pressure Range: - up to 200 MPa Pressure loading method Valve opening and closing pressure Range: - up to 200 MPa Pressure loading method Pressure resistance Range: - up to 200 MPa Pressure loading method Pressure impulse resistance Range: - up to 300 MPa Pressure loading method Fatigue strength Range: - up to 70 MPa Pressure loading method Capacity Range: - up to 80 l/min Flow measurement method PN-EN 1804-3:2021-06 (załącznik normatywny A) / (normative annex A) Hydrauliczne elementy sterujace Hydraulic controls Szczelnosc przy cisnieniu Zakres: - do 200 MPa Metoda obciazenia cisnieniem Cisnienie otwarcia i zamkniecia zaworu Zakres: - do 200 MPa Metoda obciazenia cisnieniem Odpornosc na cisnienie Zakres: - do 200 MPa Metoda obciazenia cisnieniem Odpornosc na impuls cisnienia Zakres: - do 300 MPa Metoda obciazenia cisnieniem Wytrzymalosc zmeczeniowa Zakres: - do 70 MPa Metoda obciazenia cisnieniem Przepustowosc Zakres: - do 80 l/min Metoda pomiaru przeplywu Tightness under pressure Range: - up to 200 MPa Pressure loading method Valve opening and closing pressure Range: - up to 200 MPa Pressure loading method Pressure resistance Range: - up to 200 MPa Pressure loading method Pressure impulse resistance Range: - up to 300 MPa Pressure loading method Fatigue strength Range: - up to 70 MPa Pressure loading method Capacity Range: - up to 80 l/min Flow measurement method PN-EN 1804-3:2021-06 (zalacznik normatywny A) / (normative annex A)","categories":["other"],"row_index":92,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Hydraulic controls Tightness under pressure Range: - up to 200 MPa Pressure loading method Valve opening and closing pressure Range: - up to 200 MPa Pressure loading method Pressure resistance Range: - up to 200 MPa Pressure loading method Pressure impulse resistance Range: - up to 300 MPa Pressure loading method Fatigue strength Range: - up to 70 MPa Pressure loading method Capacity Range: - up to 80 l/min Flow measurement method PN-EN 1804-3:2021-06 (załącznik normatywny A) / (normative annex A)"},{"_id":"6a5a55ef9af9f73f38250af9","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Stopy podporowe Support bases","test_object_en":"Support bases","methodology":"Wymiary liniowe Metoda pomiaru bezpośredniego Obciążenie próbne: Zakres – siła do 3000 kN Metoda obciążenia siłą Linear dimensions Direct measurement method Test load: Range – force up to 3000 kN Force method","methodology_en":"Linear dimensions Direct measurement method Test load: Range – force up to 3000 kN Force method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary liniowe Metoda pomiaru bezpośredniego Obciążenie próbne: Zakres – siła do 3000 kN Metoda obciążenia siłą Linear dimensions Direct measurement method Test load: Range – force up to 3000 kN Force method","reference":"PN-G-15023:2019-03","norm_bases":["PN-G-15023:2019-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stopy podporowe Support bases Wymiary liniowe Metoda pomiaru bezpośredniego Obciążenie próbne: Zakres – siła do 3000 kN Metoda obciążenia siłą Linear dimensions Direct measurement method Test load: Range – force up to 3000 kN Force method PN-G-15023:2019-03 Stopy podporowe Support bases Wymiary liniowe Metoda pomiaru bezposredniego Obciazenie probne: Zakres – sila do 3000 kN Metoda obciazenia sila Linear dimensions Direct measurement method Test load: Range – force up to 3000 kN Force method PN-G-15023:2019-03","categories":["other"],"row_index":93,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Support bases Linear dimensions Direct measurement method Test load: Range – force up to 3000 kN Force method PN-G-15023:2019-03"},{"_id":"6a5a55ef9af9f73f38250afa","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Siatki okładzinowe zgrzewane Welded cladding meshes","test_object_en":"Welded cladding meshes","methodology":"Wymiary liniowe Metoda pomiaru bezpośredniego Nośność siatki Zakres: - siła obciążająca do 270 kN - długość robocza siatki do 2,0 m Metoda obciążenia siłą z pomiarem przemieszczenia Wytrzymałość pręta na rozciąganie Zakres: - siła obciążająca do 50 kN - średnica pręta do 10 mm Metoda obciążenia siłą Wytrzymałość zgrzeiny na ścinanie Zakres: - siła obciążająca do 50 kN Metoda obciążenia siłą Linear dimensions Direct measurement method Mesh load capacity Range: - loading force up to 270 kN - mesh working load up to 2,0 m Force method with displacement measurement Tensile strength of the wire Range: - loading force up to 50 kN - rod diameter up to 10 mm Force method Shear strength of the weld Range: - loading force up to 50 kN Force method","methodology_en":"Linear dimensions Direct measurement method Mesh load capacity Range: - loading force up to 270 kN - mesh working load up to 2,0 m Force method with displacement measurement Tensile strength of the wire Range: - loading force up to 50 kN - rod diameter up to 10 mm Force method Shear strength of the weld Range: - loading force up to 50 kN Force method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary liniowe Metoda pomiaru bezpośredniego Nośność siatki Zakres: - siła obciążająca do 270 kN - długość robocza siatki do 2,0 m Metoda obciążenia siłą z pomiarem przemieszczenia Wytrzymałość pręta na rozciąganie Zakres: - siła obciążająca do 50 kN - średnica pręta do 10 mm Metoda obciążenia siłą Wytrzymałość zgrzeiny na ścinanie Zakres: - siła obciążająca do 50 kN Metoda obciążenia siłą Linear dimensions Direct measurement method Mesh load capacity Range: - loading force up to 270 kN - mesh working load up to 2,0 m Force method with displacement measurement Tensile strength of the wire Range: - loading force up to 50 kN - rod diameter up to 10 mm Force method Shear strength of the weld Range: - loading force up to 50 kN Force method","reference":"PN-G-15050:2018-01","norm_bases":["PN-G-15050:2018-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Siatki okładzinowe zgrzewane Welded cladding meshes Wymiary liniowe Metoda pomiaru bezpośredniego Nośność siatki Zakres: - siła obciążająca do 270 kN - długość robocza siatki do 2,0 m Metoda obciążenia siłą z pomiarem przemieszczenia Wytrzymałość pręta na rozciąganie Zakres: - siła obciążająca do 50 kN - średnica pręta do 10 mm Metoda obciążenia siłą Wytrzymałość zgrzeiny na ścinanie Zakres: - siła obciążająca do 50 kN Metoda obciążenia siłą Linear dimensions Direct measurement method Mesh load capacity Range: - loading force up to 270 kN - mesh working load up to 2,0 m Force method with displacement measurement Tensile strength of the wire Range: - loading force up to 50 kN - rod diameter up to 10 mm Force method Shear strength of the weld Range: - loading force up to 50 kN Force method PN-G-15050:2018-01 Siatki okladzinowe zgrzewane Welded cladding meshes Wymiary liniowe Metoda pomiaru bezposredniego Nosnosc siatki Zakres: - sila obciazajaca do 270 kN - dlugosc robocza siatki do 2,0 m Metoda obciazenia sila z pomiarem przemieszczenia Wytrzymalosc preta na rozciaganie Zakres: - sila obciazajaca do 50 kN - srednica preta do 10 mm Metoda obciazenia sila Wytrzymalosc zgrzeiny na scinanie Zakres: - sila obciazajaca do 50 kN Metoda obciazenia sila Linear dimensions Direct measurement method Mesh load capacity Range: - loading force up to 270 kN - mesh working load up to 2,0 m Force method with displacement measurement Tensile strength of the wire Range: - loading force up to 50 kN - rod diameter up to 10 mm Force method Shear strength of the weld Range: - loading force up to 50 kN Force method PN-G-15050:2018-01","categories":["materials"],"row_index":94,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Welded cladding meshes Linear dimensions Direct measurement method Mesh load capacity Range: - loading force up to 270 kN - mesh working load up to 2,0 m Force method with displacement measurement Tensile strength of the wire Range: - loading force up to 50 kN - rod diameter up to 10 mm Force method Shear strength of the weld Range: - loading force up to 50 kN Force method PN-G-15050:2018-01"},{"_id":"6a5a55ef9af9f73f38250afb","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Krążniki przenośników taśmowych o długości do 2100 mm i średnicy do 245 mm Belt conveyors rollers length up to 2100 mm and diameter up to 245 mm","test_object_en":"Belt conveyors rollers length up to 2100 mm and diameter up to 245 mm","methodology":"Wymiary liniowe Metoda pomiaru bezpośredniego Bicie promieniowe [mm] Metoda pomiaru złożonej tolerancji położenia i kształtu Statyczny opór obracania Zakres: - do 30 Nm Metoda obciążenia siłą Dynamiczny opór obracania Zakres: - do 200 N Metoda obciążenia siłą Linear dimensions Direct measurement method Radial runout [mm] Shape and position complex tolerance measurement method Static rotation resistance Range: - up to 30 Nm Force method Dynamic rotation resistance Range: - up to 200 N Force method","methodology_en":"Linear dimensions Direct measurement method Radial runout [mm] Shape and position complex tolerance measurement method Static rotation resistance Range: - up to 30 Nm Force method Dynamic rotation resistance Range: - up to 200 N Force method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary liniowe Metoda pomiaru bezpośredniego Bicie promieniowe [mm] Metoda pomiaru złożonej tolerancji położenia i kształtu Statyczny opór obracania Zakres: - do 30 Nm Metoda obciążenia siłą Dynamiczny opór obracania Zakres: - do 200 N Metoda obciążenia siłą Linear dimensions Direct measurement method Radial runout [mm] Shape and position complex tolerance measurement method Static rotation resistance Range: - up to 30 Nm Force method Dynamic rotation resistance Range: - up to 200 N Force method","reference":"BL-2/ZLGIG/PB-KR | PN-M-46606:2010 Procedure BL-2/ZLGIG/PB-KR 01 3rd edition of 25 August 2023 PN-M-46606:2010","norm_bases":["BL-2/ZLGIG/PB-KR","PN-M-46606:2010 Procedure BL-2/ZLGIG/PB-KR 01 3rd edition of 25 August 2023 PN-M-46606:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Krążniki przenośników taśmowych o długości do 2100 mm i średnicy do 245 mm Belt conveyors rollers length up to 2100 mm and diameter up to 245 mm Wymiary liniowe Metoda pomiaru bezpośredniego Bicie promieniowe [mm] Metoda pomiaru złożonej tolerancji położenia i kształtu Statyczny opór obracania Zakres: - do 30 Nm Metoda obciążenia siłą Dynamiczny opór obracania Zakres: - do 200 N Metoda obciążenia siłą Linear dimensions Direct measurement method Radial runout [mm] Shape and position complex tolerance measurement method Static rotation resistance Range: - up to 30 Nm Force method Dynamic rotation resistance Range: - up to 200 N Force method BL-2/ZLGIG/PB-KR | PN-M-46606:2010 Procedure BL-2/ZLGIG/PB-KR 01 3rd edition of 25 August 2023 PN-M-46606:2010 Krazniki przenosnikow tasmowych o dlugosci do 2100 mm i srednicy do 245 mm Belt conveyors rollers length up to 2100 mm and diameter up to 245 mm Wymiary liniowe Metoda pomiaru bezposredniego Bicie promieniowe [mm] Metoda pomiaru zlozonej tolerancji polozenia i ksztaltu Statyczny opor obracania Zakres: - do 30 Nm Metoda obciazenia sila Dynamiczny opor obracania Zakres: - do 200 N Metoda obciazenia sila Linear dimensions Direct measurement method Radial runout [mm] Shape and position complex tolerance measurement method Static rotation resistance Range: - up to 30 Nm Force method Dynamic rotation resistance Range: - up to 200 N Force method BL-2/ZLGIG/PB-KR | PN-M-46606:2010 Procedure BL-2/ZLGIG/PB-KR 01 3rd edition of 25 August 2023 PN-M-46606:2010","categories":["other"],"row_index":95,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Belt conveyors rollers length up to 2100 mm and diameter up to 245 mm Linear dimensions Direct measurement method Radial runout [mm] Shape and position complex tolerance measurement method Static rotation resistance Range: - up to 30 Nm Force method Dynamic rotation resistance Range: - up to 200 N Force method BL-2/ZLGIG/PB-KR | PN-M-46606:2010 Procedure BL-2/ZLGIG/PB-KR 01 3rd edition of 25 August 2023 PN-M-46606:2010"},{"_id":"6a5a55ef9af9f73f38250afc","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Rury z tworzyw termoplastycznych o średnicy wew. od 1200 do 4000 mm Thermoplastic pipes with inner diameter from 1200 up to 4000 mm","test_object_en":"Thermoplastic pipes with inner diameter from 1200 up to 4000 mm","methodology":"Sztywność obwodowa Metoda obciążenia siłą Determination of ring stiffness Force method","methodology_en":"Determination of ring stiffness Force method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sztywność obwodowa Metoda obciążenia siłą Determination of ring stiffness Force method","reference":"PN-EN 9969:2016","norm_bases":["PN-EN 9969:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury z tworzyw termoplastycznych o średnicy wew. od 1200 do 4000 mm Thermoplastic pipes with inner diameter from 1200 up to 4000 mm Sztywność obwodowa Metoda obciążenia siłą Determination of ring stiffness Force method PN-EN 9969:2016 Rury z tworzyw termoplastycznych o srednicy wew. od 1200 do 4000 mm Thermoplastic pipes with inner diameter from 1200 up to 4000 mm Sztywnosc obwodowa Metoda obciazenia sila Determination of ring stiffness Force method PN-EN 9969:2016","categories":["other"],"row_index":96,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermoplastic pipes with inner diameter from 1200 up to 4000 mm Determination of ring stiffness Force method PN-EN 9969:2016"},{"_id":"6a5a55ef9af9f73f38250afd","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Łożyska elastomerowe o wymiarach w planie do 200x300 mm Elastomeric bearings with size up to 200x300 mm","test_object_en":"Elastomeric bearings with size up to 200x300 mm","methodology":"Moduł odkształcenia postaciowego Metoda obciążenia siłą Przyczepność przy ścinaniu Metoda obciążenia siłą Sztywność przy ściskaniu Metoda obciążenia siłą Shear modulus test method Force method Shear bond test method Force method Compressive stiffness Force method","methodology_en":"Shear modulus test method Force method Shear bond test method Force method Compressive stiffness Force method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moduł odkształcenia postaciowego Metoda obciążenia siłą Przyczepność przy ścinaniu Metoda obciążenia siłą Sztywność przy ściskaniu Metoda obciążenia siłą Shear modulus test method Force method Shear bond test method Force method Compressive stiffness Force method","reference":"PN-EN 1337-3:2010 załączniki/ annexes F","norm_bases":["PN-EN 1337-3:2010 załączniki/ annexes F"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łożyska elastomerowe o wymiarach w planie do 200x300 mm Elastomeric bearings with size up to 200x300 mm Moduł odkształcenia postaciowego Metoda obciążenia siłą Przyczepność przy ścinaniu Metoda obciążenia siłą Sztywność przy ściskaniu Metoda obciążenia siłą Shear modulus test method Force method Shear bond test method Force method Compressive stiffness Force method PN-EN 1337-3:2010 załączniki/ annexes F Lozyska elastomerowe o wymiarach w planie do 200x300 mm Elastomeric bearings with size up to 200x300 mm Modul odksztalcenia postaciowego Metoda obciazenia sila Przyczepnosc przy scinaniu Metoda obciazenia sila Sztywnosc przy sciskaniu Metoda obciazenia sila Shear modulus test method Force method Shear bond test method Force method Compressive stiffness Force method PN-EN 1337-3:2010 zalaczniki/ annexes F","categories":["other"],"row_index":97,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Elastomeric bearings with size up to 200x300 mm Shear modulus test method Force method Shear bond test method Force method Compressive stiffness Force method PN-EN 1337-3:2010 załączniki/ annexes F"},{"_id":"6a5a55ef9af9f73f38250afe","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Złącza wtykowe górnicze Hydraulic plugs and connectors","test_object_en":"Hydraulic plugs and connectors","methodology":"Wymiary geometryczne Zakres: do 150 mm Metoda pomiaru bezpośredniego Ciśnienie rozrywające Zakres: do 2500 bar Metoda obciążenia ciśnieniem Geometric dimensions Range: up to 150 mm Direct measurement method Burst pressure Range: up to 2500 bar Pressure loading method","methodology_en":"Geometric dimensions Range: up to 150 mm Direct measurement method Burst pressure Range: up to 2500 bar Pressure loading method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary geometryczne Zakres: do 150 mm Metoda pomiaru bezpośredniego Ciśnienie rozrywające Zakres: do 2500 bar Metoda obciążenia ciśnieniem Geometric dimensions Range: up to 150 mm Direct measurement method Burst pressure Range: up to 2500 bar Pressure loading method","reference":"PN-G-32000:2011","norm_bases":["PN-G-32000:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Złącza wtykowe górnicze Hydraulic plugs and connectors Wymiary geometryczne Zakres: do 150 mm Metoda pomiaru bezpośredniego Ciśnienie rozrywające Zakres: do 2500 bar Metoda obciążenia ciśnieniem Geometric dimensions Range: up to 150 mm Direct measurement method Burst pressure Range: up to 2500 bar Pressure loading method PN-G-32000:2011 Zlacza wtykowe gornicze Hydraulic plugs and connectors Wymiary geometryczne Zakres: do 150 mm Metoda pomiaru bezposredniego Cisnienie rozrywajace Zakres: do 2500 bar Metoda obciazenia cisnieniem Geometric dimensions Range: up to 150 mm Direct measurement method Burst pressure Range: up to 2500 bar Pressure loading method PN-G-32000:2011","categories":["other"],"row_index":98,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Hydraulic plugs and connectors Geometric dimensions Range: up to 150 mm Direct measurement method Burst pressure Range: up to 2500 bar Pressure loading method PN-G-32000:2011"},{"_id":"6a5a55ef9af9f73f38250aff","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Skały i materiały kamienne Rocks and stone materials","test_object_en":"Rocks and stone materials","methodology":"Energetyczny wskaźnik naturalnej skłonności do tąpań (0,2 – 20) Metoda energetyczna Energetic indicator of the natural tendency to rock bumps (0,2 – 20) Energy method","methodology_en":"Energetic indicator of the natural tendency to rock bumps (0,2 – 20) Energy method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Energetyczny wskaźnik naturalnej skłonności do tąpań (0,2 – 20) Metoda energetyczna Energetic indicator of the natural tendency to rock bumps (0,2 – 20) Energy method","reference":"Procedura BL-2/ZLGIG/PB-GG-02 edycja 2 z dnia 25.08.2023 r. Procedure BL-2/ZLGIG/PB-GG-02 2nd edition of 25 August 2023","norm_bases":["Procedura BL-2/ZLGIG/PB-GG-02 edycja 2 z dnia 25.08.2023 r. Procedure BL-2/ZLGIG/PB-GG-02 2nd edition of 25 August 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Skały i materiały kamienne Rocks and stone materials Energetyczny wskaźnik naturalnej skłonności do tąpań (0,2 – 20) Metoda energetyczna Energetic indicator of the natural tendency to rock bumps (0,2 – 20) Energy method Procedura BL-2/ZLGIG/PB-GG-02 edycja 2 z dnia 25.08.2023 r. Procedure BL-2/ZLGIG/PB-GG-02 2nd edition of 25 August 2023 Skaly i materialy kamienne Rocks and stone materials Energetyczny wskaznik naturalnej sklonnosci do tapan (0,2 – 20) Metoda energetyczna Energetic indicator of the natural tendency to rock bumps (0,2 – 20) Energy method Procedura BL-2/ZLGIG/PB-GG-02 edycja 2 z dnia 25.08.2023 r. Procedure BL-2/ZLGIG/PB-GG-02 2nd edition of 25 August 2023","categories":["materials"],"row_index":99,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rocks and stone materials Energetic indicator of the natural tendency to rock bumps (0,2 – 20) Energy method Procedura BL-2/ZLGIG/PB-GG-02 edycja 2 z dnia 25.08.2023 r. Procedure BL-2/ZLGIG/PB-GG-02 2nd edition of 25 August 2023","search_zh":"岩石与石材 Rocks and stone materials Procedura BL-2/ZLGIG/PB-GG-02 edycja 2 z dnia 25.08.2023 r. Procedure BL-2/ZLGIG/PB-GG-02 2nd edition of 25 August 2023","test_object_zh":"岩石与石材 Rocks and stone materials"},{"_id":"6a5a55ef9af9f73f38250b00","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Skały i materiały kamienne Rocks and stone materials","test_object_en":"Rocks and stone materials","methodology":"Porowatość całkowita Total porosity","methodology_en":"Total porosity","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Porowatość całkowita Total porosity","reference":"PN-EN 1936:2010","norm_bases":["PN-EN 1936:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Skały i materiały kamienne Rocks and stone materials Porowatość całkowita Total porosity PN-EN 1936:2010 Skaly i materialy kamienne Rocks and stone materials Porowatosc calkowita Total porosity PN-EN 1936:2010","categories":["materials"],"row_index":100,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rocks and stone materials Total porosity PN-EN 1936:2010","search_zh":"岩石与石材 Rocks and stone materials PN-EN 1936:2010","test_object_zh":"岩石与石材 Rocks and stone materials"},{"_id":"6a5a55ef9af9f73f38250b01","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Skały i materiały kamienne Rocks and stone materials","test_object_en":"Rocks and stone materials","methodology":"Wilgotność próbki Metoda wagowa Sample moisture Weight method","methodology_en":"Sample moisture Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wilgotność próbki Metoda wagowa Sample moisture Weight method","reference":"PN-88/B-04481","norm_bases":["PN-88/B-04481"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Skały i materiały kamienne Rocks and stone materials Wilgotność próbki Metoda wagowa Sample moisture Weight method PN-88/B-04481 Skaly i materialy kamienne Rocks and stone materials Wilgotnosc probki Metoda wagowa Sample moisture Weight method PN-88/B-04481","categories":["materials"],"row_index":101,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rocks and stone materials Sample moisture Weight method PN-88/B-04481","search_zh":"岩石与石材 Rocks and stone materials PN-88/B-04481","test_object_zh":"岩石与石材 Rocks and stone materials"},{"_id":"6a5a55ef9af9f73f38250b02","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Skały i materiały kamienne Rocks and stone materials","test_object_en":"Rocks and stone materials","methodology":"Wytrzymałość na ściskanie w zakresie siły (25 – 1000) kN Wytrzymałość resztkowa w zakresie siły (25 – 1000) kN Wskaźnik potencjalnej energii sprężystej w zakresie siły (25 – 1000) kN Moduł spadku w zakresie siły (25 – 1000) kN Odkształcenie krytyczne i resztkowe (0,1 – 100) mm Compressive strength in the force range (25 – 1000) kN Residual strength in the force range (25 – 1000) kN Index of the potential elastic energy in the force range (25 – 1000) kN Drop modulus in the force range (25 – 1000) kN Critical and residual deformation (0,1 – 100) mm","methodology_en":"Compressive strength in the force range (25 – 1000) kN Residual strength in the force range (25 – 1000) kN Index of the potential elastic energy in the force range (25 – 1000) kN Drop modulus in the force range (25 – 1000) kN Critical and residual deformation (0,1 – 100) mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie w zakresie siły (25 – 1000) kN Wytrzymałość resztkowa w zakresie siły (25 – 1000) kN Wskaźnik potencjalnej energii sprężystej w zakresie siły (25 – 1000) kN Moduł spadku w zakresie siły (25 – 1000) kN Odkształcenie krytyczne i resztkowe (0,1 – 100) mm Compressive strength in the force range (25 – 1000) kN Residual strength in the force range (25 – 1000) kN Index of the potential elastic energy in the force range (25 – 1000) kN Drop modulus in the force range (25 – 1000) kN Critical and residual deformation (0,1 – 100) mm","reference":"BL-2/ZLGIG/PB-GG-01 | PN-G-04303:1997 PN-EN 1926:2007 Procedure BL-2/ZLGIG/PB-GG-01 2nd edition of 25 August 2023 PN-G-04303:1997 PN-EN 1926:2007","norm_bases":["BL-2/ZLGIG/PB-GG-01","PN-G-04303:1997 PN-EN 1926:2007 Procedure BL-2/ZLGIG/PB-GG-01 2nd edition of 25 August 2023 PN-G-04303:1997 PN-EN 1926:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Skały i materiały kamienne Rocks and stone materials Wytrzymałość na ściskanie w zakresie siły (25 – 1000) kN Wytrzymałość resztkowa w zakresie siły (25 – 1000) kN Wskaźnik potencjalnej energii sprężystej w zakresie siły (25 – 1000) kN Moduł spadku w zakresie siły (25 – 1000) kN Odkształcenie krytyczne i resztkowe (0,1 – 100) mm Compressive strength in the force range (25 – 1000) kN Residual strength in the force range (25 – 1000) kN Index of the potential elastic energy in the force range (25 – 1000) kN Drop modulus in the force range (25 – 1000) kN Critical and residual deformation (0,1 – 100) mm BL-2/ZLGIG/PB-GG-01 | PN-G-04303:1997 PN-EN 1926:2007 Procedure BL-2/ZLGIG/PB-GG-01 2nd edition of 25 August 2023 PN-G-04303:1997 PN-EN 1926:2007 Skaly i materialy kamienne Rocks and stone materials Wytrzymalosc na sciskanie w zakresie sily (25 – 1000) kN Wytrzymalosc resztkowa w zakresie sily (25 – 1000) kN Wskaznik potencjalnej energii sprezystej w zakresie sily (25 – 1000) kN Modul spadku w zakresie sily (25 – 1000) kN Odksztalcenie krytyczne i resztkowe (0,1 – 100) mm Compressive strength in the force range (25 – 1000) kN Residual strength in the force range (25 – 1000) kN Index of the potential elastic energy in the force range (25 – 1000) kN Drop modulus in the force range (25 – 1000) kN Critical and residual deformation (0,1 – 100) mm BL-2/ZLGIG/PB-GG-01 | PN-G-04303:1997 PN-EN 1926:2007 Procedure BL-2/ZLGIG/PB-GG-01 2nd edition of 25 August 2023 PN-G-04303:1997 PN-EN 1926:2007","categories":["materials"],"row_index":102,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rocks and stone materials Compressive strength in the force range (25 – 1000) kN Residual strength in the force range (25 – 1000) kN Index of the potential elastic energy in the force range (25 – 1000) kN Drop modulus in the force range (25 – 1000) kN Critical and residual deformation (0,1 – 100) mm BL-2/ZLGIG/PB-GG-01 | PN-G-04303:1997 PN-EN 1926:2007 Procedure BL-2/ZLGIG/PB-GG-01 2nd edition of 25 August 2023 PN-G-04303:1997 PN-EN 1926:2007","search_zh":"岩石与石材 Rocks and stone materials BL-2/ZLGIG/PB-GG-01 | PN-G-04303:1997 PN-EN 1926:2007 Procedure BL-2/ZLGIG/PB-GG-01 2nd edition of 25 August 2023 PN-G-04303:1997 PN-EN 1926:2007","test_object_zh":"岩石与石材 Rocks and stone materials"},{"_id":"6a5a55ef9af9f73f38250b03","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Skały i materiały kamienne Rocks and stone materials","test_object_en":"Rocks and stone materials","methodology":"Wytrzymałość na rozciąganie w zakresie siły (25 – 1000) kN Metoda Brazylijska Tensile strength in the force range (25 – 1000) kN Brazilian method","methodology_en":"Tensile strength in the force range (25 – 1000) kN Brazilian method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na rozciąganie w zakresie siły (25 – 1000) kN Metoda Brazylijska Tensile strength in the force range (25 – 1000) kN Brazilian method","reference":"PN-G-04302:1997","norm_bases":["PN-G-04302:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Skały i materiały kamienne Rocks and stone materials Wytrzymałość na rozciąganie w zakresie siły (25 – 1000) kN Metoda Brazylijska Tensile strength in the force range (25 – 1000) kN Brazilian method PN-G-04302:1997 Skaly i materialy kamienne Rocks and stone materials Wytrzymalosc na rozciaganie w zakresie sily (25 – 1000) kN Metoda Brazylijska Tensile strength in the force range (25 – 1000) kN Brazilian method PN-G-04302:1997","categories":["materials"],"row_index":103,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rocks and stone materials Tensile strength in the force range (25 – 1000) kN Brazilian method PN-G-04302:1997","search_zh":"岩石与石材 Rocks and stone materials PN-G-04302:1997","test_object_zh":"岩石与石材 Rocks and stone materials"},{"_id":"6a5a55ef9af9f73f38250b04","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Skały i materiały kamienne Rocks and stone materials","test_object_en":"Rocks and stone materials","methodology":"Wytrzymałość na ścinanie w zakresie siły (25 – 1000) kN Metoda ścinania prostego Shear strength in the force range (25 – 1000) kN Simple shear method","methodology_en":"Shear strength in the force range (25 – 1000) kN Simple shear method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ścinanie w zakresie siły (25 – 1000) kN Metoda ścinania prostego Shear strength in the force range (25 – 1000) kN Simple shear method","reference":"PN-G-04304:1997+Az1:1999","norm_bases":["PN-G-04304:1997+Az1:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Skały i materiały kamienne Rocks and stone materials Wytrzymałość na ścinanie w zakresie siły (25 – 1000) kN Metoda ścinania prostego Shear strength in the force range (25 – 1000) kN Simple shear method PN-G-04304:1997+Az1:1999 Skaly i materialy kamienne Rocks and stone materials Wytrzymalosc na scinanie w zakresie sily (25 – 1000) kN Metoda scinania prostego Shear strength in the force range (25 – 1000) kN Simple shear method PN-G-04304:1997+Az1:1999","categories":["materials"],"row_index":104,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rocks and stone materials Shear strength in the force range (25 – 1000) kN Simple shear method PN-G-04304:1997+Az1:1999","search_zh":"岩石与石材 Rocks and stone materials PN-G-04304:1997+Az1:1999","test_object_zh":"岩石与石材 Rocks and stone materials"},{"_id":"6a5a55ef9af9f73f38250b05","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Skały i materiały kamienne Rocks and stone materials","test_object_en":"Rocks and stone materials","methodology":"Gęstość objętościowa Metoda wagowo-objętościowa Bulk density Weight-volume method","methodology_en":"Bulk density Weight-volume method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Gęstość objętościowa Metoda wagowo-objętościowa Bulk density Weight-volume method","reference":"PN-EN 1936:2010","norm_bases":["PN-EN 1936:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Skały i materiały kamienne Rocks and stone materials Gęstość objętościowa Metoda wagowo-objętościowa Bulk density Weight-volume method PN-EN 1936:2010 Skaly i materialy kamienne Rocks and stone materials Gestosc objetosciowa Metoda wagowo-objetosciowa Bulk density Weight-volume method PN-EN 1936:2010","categories":["materials"],"row_index":105,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rocks and stone materials Bulk density Weight-volume method PN-EN 1936:2010","search_zh":"岩石与石材 Rocks and stone materials PN-EN 1936:2010","test_object_zh":"岩石与石材 Rocks and stone materials"},{"_id":"6a5a55ef9af9f73f38250b06","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Skały i materiały kamienne Rocks and stone materials","test_object_en":"Rocks and stone materials","methodology":"Gęstość właściwa Metoda kolby Le Chateliera Specific density Le Chatelier's flask method","methodology_en":"Specific density Le Chatelier's flask method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Gęstość właściwa Metoda kolby Le Chateliera Specific density Le Chatelier's flask method","reference":"PN-EN 1936:2010","norm_bases":["PN-EN 1936:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Skały i materiały kamienne Rocks and stone materials Gęstość właściwa Metoda kolby Le Chateliera Specific density Le Chatelier's flask method PN-EN 1936:2010 Skaly i materialy kamienne Rocks and stone materials Gestosc wlasciwa Metoda kolby Le Chateliera Specific density Le Chatelier's flask method PN-EN 1936:2010","categories":["materials"],"row_index":106,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rocks and stone materials Specific density Le Chatelier's flask method PN-EN 1936:2010","search_zh":"岩石与石材 Rocks and stone materials PN-EN 1936:2010","test_object_zh":"岩石与石材 Rocks and stone materials"},{"_id":"6a5a55ef9af9f73f38250b07","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Skały i materiały kamienne Rocks and stone materials","test_object_en":"Rocks and stone materials","methodology":"Wytrzymałość na zginanie w zakresie siły (25 – 1000) kN Bending strength in the force range (25 – 1000) kN","methodology_en":"Bending strength in the force range (25 – 1000) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na zginanie w zakresie siły (25 – 1000) kN Bending strength in the force range (25 – 1000) kN","reference":"PN-G-04305:1997 PN-EN 12372:2010","norm_bases":["PN-G-04305:1997 PN-EN 12372:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Skały i materiały kamienne Rocks and stone materials Wytrzymałość na zginanie w zakresie siły (25 – 1000) kN Bending strength in the force range (25 – 1000) kN PN-G-04305:1997 PN-EN 12372:2010 Skaly i materialy kamienne Rocks and stone materials Wytrzymalosc na zginanie w zakresie sily (25 – 1000) kN Bending strength in the force range (25 – 1000) kN PN-G-04305:1997 PN-EN 12372:2010","categories":["materials"],"row_index":107,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rocks and stone materials Bending strength in the force range (25 – 1000) kN PN-G-04305:1997 PN-EN 12372:2010","search_zh":"岩石与石材 Rocks and stone materials PN-G-04305:1997 PN-EN 12372:2010","test_object_zh":"岩石与石材 Rocks and stone materials"},{"_id":"6a5a55ef9af9f73f38250b08","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Skały i materiały kamienne Rocks and stone materials","test_object_en":"Rocks and stone materials","methodology":"Moduł Younga w zakresie siły (25 – 1000) kN Young's modulus in the force range (25 – 1000) kN","methodology_en":"Young's modulus in the force range (25 – 1000) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moduł Younga w zakresie siły (25 – 1000) kN Young's modulus in the force range (25 – 1000) kN","reference":"Procedura BL-2/ZLGIG/PB-GG-03 edycja 3 z dnia 05.11.2025 r. Procedure BL-2/ZLGIG/PB-GG-03 3nd edition of 05 November 2025","norm_bases":["Procedura BL-2/ZLGIG/PB-GG-03 edycja 3 z dnia 05.11.2025 r. Procedure BL-2/ZLGIG/PB-GG-03 3nd edition of 05 November 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Skały i materiały kamienne Rocks and stone materials Moduł Younga w zakresie siły (25 – 1000) kN Young's modulus in the force range (25 – 1000) kN Procedura BL-2/ZLGIG/PB-GG-03 edycja 3 z dnia 05.11.2025 r. Procedure BL-2/ZLGIG/PB-GG-03 3nd edition of 05 November 2025 Skaly i materialy kamienne Rocks and stone materials Modul Younga w zakresie sily (25 – 1000) kN Young's modulus in the force range (25 – 1000) kN Procedura BL-2/ZLGIG/PB-GG-03 edycja 3 z dnia 05.11.2025 r. Procedure BL-2/ZLGIG/PB-GG-03 3nd edition of 05 November 2025","categories":["materials"],"row_index":108,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rocks and stone materials Young's modulus in the force range (25 – 1000) kN Procedura BL-2/ZLGIG/PB-GG-03 edycja 3 z dnia 05.11.2025 r. Procedure BL-2/ZLGIG/PB-GG-03 3nd edition of 05 November 2025","search_zh":"岩石与石材 Rocks and stone materials Procedura BL-2/ZLGIG/PB-GG-03 edycja 3 z dnia 05.11.2025 r. Procedure BL-2/ZLGIG/PB-GG-03 3nd edition of 05 November 2025","test_object_zh":"岩石与石材 Rocks and stone materials"},{"_id":"6a5a55ef9af9f73f38250b09","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Skały i materiały kamienne Rocks and stone materials","test_object_en":"Rocks and stone materials","methodology":"Nasiąkliwość Metoda wagowa Water absorption Weight method","methodology_en":"Water absorption Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nasiąkliwość Metoda wagowa Water absorption Weight method","reference":"PN-EN 13755:2008+AC:2004","norm_bases":["PN-EN 13755:2008+AC:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Skały i materiały kamienne Rocks and stone materials Nasiąkliwość Metoda wagowa Water absorption Weight method PN-EN 13755:2008+AC:2004 Skaly i materialy kamienne Rocks and stone materials Nasiakliwosc Metoda wagowa Water absorption Weight method PN-EN 13755:2008+AC:2004","categories":["materials","water"],"row_index":109,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rocks and stone materials Water absorption Weight method PN-EN 13755:2008+AC:2004","search_zh":"岩石与石材 Rocks and stone materials PN-EN 13755:2008+AC:2004","test_object_zh":"岩石与石材 Rocks and stone materials"},{"_id":"6a5a55ef9af9f73f38250b0a","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Skały zwięzłe Rocks concise","test_object_en":"Rocks concise","methodology":"Rozmakalność Metody jakościowe: Skutty i GIG Conversibility Qualitative methods: Skutta and GIG","methodology_en":"Conversibility Qualitative methods: Skutta and GIG","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Rozmakalność Metody jakościowe: Skutty i GIG Conversibility Qualitative methods: Skutta and GIG","reference":"Procedura BL-2/ZLGIG/PB-GG-04 edycja 2 z dnia 25.08.2023 r. Procedure BL-2/ZLGIG/PB-GG-04 2nd edition of 25 August 2023","norm_bases":["Procedura BL-2/ZLGIG/PB-GG-04 edycja 2 z dnia 25.08.2023 r. Procedure BL-2/ZLGIG/PB-GG-04 2nd edition of 25 August 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Skały zwięzłe Rocks concise Rozmakalność Metody jakościowe: Skutty i GIG Conversibility Qualitative methods: Skutta and GIG Procedura BL-2/ZLGIG/PB-GG-04 edycja 2 z dnia 25.08.2023 r. Procedure BL-2/ZLGIG/PB-GG-04 2nd edition of 25 August 2023 Skaly zwiezle Rocks concise Rozmakalnosc Metody jakosciowe: Skutty i GIG Conversibility Qualitative methods: Skutta and GIG Procedura BL-2/ZLGIG/PB-GG-04 edycja 2 z dnia 25.08.2023 r. Procedure BL-2/ZLGIG/PB-GG-04 2nd edition of 25 August 2023","categories":["other"],"row_index":110,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rocks concise Conversibility Qualitative methods: Skutta and GIG Procedura BL-2/ZLGIG/PB-GG-04 edycja 2 z dnia 25.08.2023 r. Procedure BL-2/ZLGIG/PB-GG-04 2nd edition of 25 August 2023"},{"_id":"6a5a55ef9af9f73f38250b0b","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Beton Concrete","test_object_en":"Concrete","methodology":"Nasiąkliwość Metoda wagowa Water absorption Weight method","methodology_en":"Water absorption Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nasiąkliwość Metoda wagowa Water absorption Weight method","reference":"PN-EN 13755:2008+AC:2004","norm_bases":["PN-EN 13755:2008+AC:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton Concrete Nasiąkliwość Metoda wagowa Water absorption Weight method PN-EN 13755:2008+AC:2004 Beton Concrete Nasiakliwosc Metoda wagowa Water absorption Weight method PN-EN 13755:2008+AC:2004","categories":["construction","water"],"row_index":111,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete Water absorption Weight method PN-EN 13755:2008+AC:2004","search_zh":"混凝土 Concrete PN-EN 13755:2008+AC:2004","test_object_zh":"混凝土 Concrete"},{"_id":"6a5a55ef9af9f73f38250b0c","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Beton Concrete","test_object_en":"Concrete","methodology":"Wytrzymałość na ściskanie w zakresie siły (25 – 1000) kN Compressive strength in the force range (25 – 1000) kN","methodology_en":"Compressive strength in the force range (25 – 1000) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie w zakresie siły (25 – 1000) kN Compressive strength in the force range (25 – 1000) kN","reference":"PN-EN 12390-3:2011","norm_bases":["PN-EN 12390-3:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton Concrete Wytrzymałość na ściskanie w zakresie siły (25 – 1000) kN Compressive strength in the force range (25 – 1000) kN PN-EN 12390-3:2011 Beton Concrete Wytrzymalosc na sciskanie w zakresie sily (25 – 1000) kN Compressive strength in the force range (25 – 1000) kN PN-EN 12390-3:2011","categories":["construction"],"row_index":112,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete Compressive strength in the force range (25 – 1000) kN PN-EN 12390-3:2011","search_zh":"混凝土 Concrete PN-EN 12390-3:2011","test_object_zh":"混凝土 Concrete"},{"_id":"6a5a55ef9af9f73f38250b0d","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Żywice organiczne i organiczno-mineralne Organic and organo-mineral resins","test_object_en":"Organic and organo-mineral resins","methodology":"Wytrzymałość na ściskanie i odkształcenie względne w zakresie siły (25 – 1000) kN Compressive strength and the relative deformation in the force range (25 – 1000) kN","methodology_en":"Compressive strength and the relative deformation in the force range (25 – 1000) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie i odkształcenie względne w zakresie siły (25 – 1000) kN Compressive strength and the relative deformation in the force range (25 – 1000) kN","reference":"PN-C-89071:1993","norm_bases":["PN-C-89071:1993"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żywice organiczne i organiczno-mineralne Organic and organo-mineral resins Wytrzymałość na ściskanie i odkształcenie względne w zakresie siły (25 – 1000) kN Compressive strength and the relative deformation in the force range (25 – 1000) kN PN-C-89071:1993 Zywice organiczne i organiczno-mineralne Organic and organo-mineral resins Wytrzymalosc na sciskanie i odksztalcenie wzgledne w zakresie sily (25 – 1000) kN Compressive strength and the relative deformation in the force range (25 – 1000) kN PN-C-89071:1993","categories":["other"],"row_index":113,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Organic and organo-mineral resins Compressive strength and the relative deformation in the force range (25 – 1000) kN PN-C-89071:1993"},{"_id":"6a5a55ef9af9f73f38250b0e","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Samozapalność węgla Zakres: (1 – 250) ºC/min Metoda Olpińskiego Susceptibility of coal to spontaneous combustion Range: (1 – 250) ºC/min Olpinski method","methodology_en":"Susceptibility of coal to spontaneous combustion Range: (1 – 250) ºC/min Olpinski method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Samozapalność węgla Zakres: (1 – 250) ºC/min Metoda Olpińskiego Susceptibility of coal to spontaneous combustion Range: (1 – 250) ºC/min Olpinski method","reference":"PN-G-04558:1993","norm_bases":["PN-G-04558:1993"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Samozapalność węgla Zakres: (1 – 250) ºC/min Metoda Olpińskiego Susceptibility of coal to spontaneous combustion Range: (1 – 250) ºC/min Olpinski method PN-G-04558:1993 Paliwa stale: wegiel kamienny Solid fuels: hard coal Samozapalnosc wegla Zakres: (1 – 250) ºC/min Metoda Olpinskiego Susceptibility of coal to spontaneous combustion Range: (1 – 250) ºC/min Olpinski method PN-G-04558:1993","categories":["petro"],"row_index":114,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Susceptibility of coal to spontaneous combustion Range: (1 – 250) ºC/min Olpinski method PN-G-04558:1993","search_zh":"固体燃料：烟煤 PN-G-04558:1993","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ef9af9f73f38250b0f","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci przemijającej Zakres: (0,1 – 20,0) % Metoda wagowa Transient moisture content Range: (0,1 – 20,0) % Weight method","methodology_en":"Transient moisture content Range: (0,1 – 20,0) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci przemijającej Zakres: (0,1 – 20,0) % Metoda wagowa Transient moisture content Range: (0,1 – 20,0) % Weight method","reference":"PN-G-04511:1980","norm_bases":["PN-G-04511:1980"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Zawartość wilgoci przemijającej Zakres: (0,1 – 20,0) % Metoda wagowa Transient moisture content Range: (0,1 – 20,0) % Weight method PN-G-04511:1980 Paliwa stale: wegiel kamienny Solid fuels: hard coal Zawartosc wilgoci przemijajacej Zakres: (0,1 – 20,0) % Metoda wagowa Transient moisture content Range: (0,1 – 20,0) % Weight method PN-G-04511:1980","categories":["petro"],"row_index":115,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Transient moisture content Range: (0,1 – 20,0) % Weight method PN-G-04511:1980","search_zh":"固体燃料：烟煤 PN-G-04511:1980","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ef9af9f73f38250b10","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci w próbce analitycznej Zakres: (0,1 – 20,0) % Metoda wagowa Moisture content in analytical sample Range: (0,1 – 20,0) % Weight method","methodology_en":"Moisture content in analytical sample Range: (0,1 – 20,0) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej Zakres: (0,1 – 20,0) % Metoda wagowa Moisture content in analytical sample Range: (0,1 – 20,0) % Weight method","reference":"PN-G-04511:1980 punkt 2.4.1","norm_bases":["PN-G-04511:1980 punkt 2.4.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Zawartość wilgoci w próbce analitycznej Zakres: (0,1 – 20,0) % Metoda wagowa Moisture content in analytical sample Range: (0,1 – 20,0) % Weight method PN-G-04511:1980 punkt 2.4.1 Paliwa stale: wegiel kamienny Solid fuels: hard coal Zawartosc wilgoci w probce analitycznej Zakres: (0,1 – 20,0) % Metoda wagowa Moisture content in analytical sample Range: (0,1 – 20,0) % Weight method PN-G-04511:1980 punkt 2.4.1","categories":["petro"],"row_index":116,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Moisture content in analytical sample Range: (0,1 – 20,0) % Weight method PN-G-04511:1980 punkt 2.4.1","search_zh":"固体燃料：烟煤 PN-G-04511:1980 punkt 2.4.1","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ef9af9f73f38250b11","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość popiołu Zakres: (0,1 – 30,0) % Metoda wagowa Ash content Range: (0,1 – 30,0) % Weight method","methodology_en":"Ash content Range: (0,1 – 30,0) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość popiołu Zakres: (0,1 – 30,0) % Metoda wagowa Ash content Range: (0,1 – 30,0) % Weight method","reference":"Procedura BD-3/ZLGIG/PB-PO.03 edycja 2 z dnia 25.08.2023 r. Procedure BD-3/ZLGIG/PB-PO.03 2nd edition of 25 August 2023","norm_bases":["Procedura BD-3/ZLGIG/PB-PO.03 edycja 2 z dnia 25.08.2023 r. Procedure BD-3/ZLGIG/PB-PO.03 2nd edition of 25 August 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Zawartość popiołu Zakres: (0,1 – 30,0) % Metoda wagowa Ash content Range: (0,1 – 30,0) % Weight method Procedura BD-3/ZLGIG/PB-PO.03 edycja 2 z dnia 25.08.2023 r. Procedure BD-3/ZLGIG/PB-PO.03 2nd edition of 25 August 2023 Paliwa stale: wegiel kamienny Solid fuels: hard coal Zawartosc popiolu Zakres: (0,1 – 30,0) % Metoda wagowa Ash content Range: (0,1 – 30,0) % Weight method Procedura BD-3/ZLGIG/PB-PO.03 edycja 2 z dnia 25.08.2023 r. Procedure BD-3/ZLGIG/PB-PO.03 2nd edition of 25 August 2023","categories":["petro"],"row_index":117,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Ash content Range: (0,1 – 30,0) % Weight method Procedura BD-3/ZLGIG/PB-PO.03 edycja 2 z dnia 25.08.2023 r. Procedure BD-3/ZLGIG/PB-PO.03 2nd edition of 25 August 2023","search_zh":"固体燃料：烟煤 Procedura BD-3/ZLGIG/PB-PO.03 edycja 2 z dnia 25.08.2023 r. Procedure BD-3/ZLGIG/PB-PO.03 2nd edition of 25 August 2023","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ef9af9f73f38250b12","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Środowisko ogólne Próbki gazowe General environment Gas samples","test_object_en":"General environment Gas samples","methodology":"Stężenie tlenku węgla Zakres: (1 – 10000) ppm Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Concentration of carbon monoxide Range: (1 – 10000) ppm Gas chromatography method with flame ionization detection (GC-FID)","methodology_en":"Concentration of carbon monoxide Range: (1 – 10000) ppm Gas chromatography method with flame ionization detection (GC-FID)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenku węgla Zakres: (1 – 10000) ppm Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Concentration of carbon monoxide Range: (1 – 10000) ppm Gas chromatography method with flame ionization detection (GC-FID)","reference":"Procedura BD-3/ZLGIG/PB-CO.04 edycja 3 z dnia 06.11.2023 r. Procedure BD-3/ZLGIG/PB-CO.04 3rd edition of 6 November 2023","norm_bases":["Procedura BD-3/ZLGIG/PB-CO.04 edycja 3 z dnia 06.11.2023 r. Procedure BD-3/ZLGIG/PB-CO.04 3rd edition of 6 November 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne Próbki gazowe General environment Gas samples Stężenie tlenku węgla Zakres: (1 – 10000) ppm Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Concentration of carbon monoxide Range: (1 – 10000) ppm Gas chromatography method with flame ionization detection (GC-FID) Procedura BD-3/ZLGIG/PB-CO.04 edycja 3 z dnia 06.11.2023 r. Procedure BD-3/ZLGIG/PB-CO.04 3rd edition of 6 November 2023 Srodowisko ogolne Probki gazowe General environment Gas samples Stezenie tlenku wegla Zakres: (1 – 10000) ppm Metoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Concentration of carbon monoxide Range: (1 – 10000) ppm Gas chromatography method with flame ionization detection (GC-FID) Procedura BD-3/ZLGIG/PB-CO.04 edycja 3 z dnia 06.11.2023 r. Procedure BD-3/ZLGIG/PB-CO.04 3rd edition of 6 November 2023","categories":["environment"],"row_index":118,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment Gas samples Concentration of carbon monoxide Range: (1 – 10000) ppm Gas chromatography method with flame ionization detection (GC-FID) Procedura BD-3/ZLGIG/PB-CO.04 edycja 3 z dnia 06.11.2023 r. Procedure BD-3/ZLGIG/PB-CO.04 3rd edition of 6 November 2023","search_zh":"一般环境 气体样品 General environment Gas samples Procedura BD-3/ZLGIG/PB-CO.04 edycja 3 z dnia 06.11.2023 r. Procedure BD-3/ZLGIG/PB-CO.04 3rd edition of 6 November 2023","test_object_zh":"一般环境 气体样品 General environment Gas samples"},{"_id":"6a5a55ef9af9f73f38250b13","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Środowisko ogólne Próbki gazowe General environment Gas samples","test_object_en":"General environment Gas samples","methodology":"Stężenie tlenku węgla Zakres: (70 – 10000) ppm Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) Concentration of carbon monoxide Range: (70 – 10000) ppm Gas chromatography method with thermal conductivity detector GC-TCD)","methodology_en":"Concentration of carbon monoxide Range: (70 – 10000) ppm Gas chromatography method with thermal conductivity detector GC-TCD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenku węgla Zakres: (70 – 10000) ppm Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) Concentration of carbon monoxide Range: (70 – 10000) ppm Gas chromatography method with thermal conductivity detector GC-TCD)","reference":"Procedura BD-3/ZLGIG/PB-CO.04 edycja 3 z dnia 06.11.2023 r. . Procedure BD-3/ZLGIG/PB-CO.04 3rd edition of 6 November 2023","norm_bases":["Procedura BD-3/ZLGIG/PB-CO.04 edycja 3 z dnia 06.11.2023 r. . Procedure BD-3/ZLGIG/PB-CO.04 3rd edition of 6 November 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne Próbki gazowe General environment Gas samples Stężenie tlenku węgla Zakres: (70 – 10000) ppm Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) Concentration of carbon monoxide Range: (70 – 10000) ppm Gas chromatography method with thermal conductivity detector GC-TCD) Procedura BD-3/ZLGIG/PB-CO.04 edycja 3 z dnia 06.11.2023 r. . Procedure BD-3/ZLGIG/PB-CO.04 3rd edition of 6 November 2023 Srodowisko ogolne Probki gazowe General environment Gas samples Stezenie tlenku wegla Zakres: (70 – 10000) ppm Metoda chromatografii gazowej z detekcja termokonduktometryczna (GC-TCD) Concentration of carbon monoxide Range: (70 – 10000) ppm Gas chromatography method with thermal conductivity detector GC-TCD) Procedura BD-3/ZLGIG/PB-CO.04 edycja 3 z dnia 06.11.2023 r. . Procedure BD-3/ZLGIG/PB-CO.04 3rd edition of 6 November 2023","categories":["environment"],"row_index":119,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment Gas samples Concentration of carbon monoxide Range: (70 – 10000) ppm Gas chromatography method with thermal conductivity detector GC-TCD) Procedura BD-3/ZLGIG/PB-CO.04 edycja 3 z dnia 06.11.2023 r. . Procedure BD-3/ZLGIG/PB-CO.04 3rd edition of 6 November 2023","search_zh":"一般环境 气体样品 General environment Gas samples Procedura BD-3/ZLGIG/PB-CO.04 edycja 3 z dnia 06.11.2023 r. . Procedure BD-3/ZLGIG/PB-CO.04 3rd edition of 6 November 2023","test_object_zh":"一般环境 气体样品 General environment Gas samples"},{"_id":"6a5a55ef9af9f73f38250b14","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Środowisko ogólne Próbki gazowe General environment Gas samples","test_object_en":"General environment Gas samples","methodology":"Stężenie tlenu, azotu, dwutlenku węgla, metanu, tlenku węgla Zakres: tlen (0,05 – 22) % azot (4 – 100) % ditlenek węgla (0,05 – 50) % metan (0,05 – 100) % tlenek węgla (0,1 – 5) % wodór (1 – 4) % Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) Concentration of oxygen, nitrogen, carbon dioxide, methane, carbon monoxide, ethane, ethylene Range: oxygen (0,05 – 22) % nitrogen (4 – 100) % carbon dioxide (0,05 – 50) % methane (0,05 – 100) % carbon monoxide (0,1 – 5) % hydrogen (1 – 4) % Gas chromatography method with thermal conductivity detector (GC-TCD)","methodology_en":"Concentration of oxygen, nitrogen, carbon dioxide, methane, carbon monoxide, ethane, ethylene Range: oxygen (0,05 – 22) % nitrogen (4 – 100) % carbon dioxide (0,05 – 50) % methane (0,05 – 100) % carbon monoxide (0,1 – 5) % hydrogen (1 – 4) % Gas chromatography method with thermal conductivity detector (GC-TCD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenu, azotu, dwutlenku węgla, metanu, tlenku węgla Zakres: tlen (0,05 – 22) % azot (4 – 100) % ditlenek węgla (0,05 – 50) % metan (0,05 – 100) % tlenek węgla (0,1 – 5) % wodór (1 – 4) % Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) Concentration of oxygen, nitrogen, carbon dioxide, methane, carbon monoxide, ethane, ethylene Range: oxygen (0,05 – 22) % nitrogen (4 – 100) % carbon dioxide (0,05 – 50) % methane (0,05 – 100) % carbon monoxide (0,1 – 5) % hydrogen (1 – 4) % Gas chromatography method with thermal conductivity detector (GC-TCD)","reference":"Procedura BD-3/ZLGIG/PB-TL.05 edycja 4 z dnia 23.11.2023 r. Procedure BD-3/ZLGIG/PB-TL.05 4th edition of 23 November 2023","norm_bases":["Procedura BD-3/ZLGIG/PB-TL.05 edycja 4 z dnia 23.11.2023 r. Procedure BD-3/ZLGIG/PB-TL.05 4th edition of 23 November 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne Próbki gazowe General environment Gas samples Stężenie tlenu, azotu, dwutlenku węgla, metanu, tlenku węgla Zakres: tlen (0,05 – 22) % azot (4 – 100) % ditlenek węgla (0,05 – 50) % metan (0,05 – 100) % tlenek węgla (0,1 – 5) % wodór (1 – 4) % Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) Concentration of oxygen, nitrogen, carbon dioxide, methane, carbon monoxide, ethane, ethylene Range: oxygen (0,05 – 22) % nitrogen (4 – 100) % carbon dioxide (0,05 – 50) % methane (0,05 – 100) % carbon monoxide (0,1 – 5) % hydrogen (1 – 4) % Gas chromatography method with thermal conductivity detector (GC-TCD) Procedura BD-3/ZLGIG/PB-TL.05 edycja 4 z dnia 23.11.2023 r. Procedure BD-3/ZLGIG/PB-TL.05 4th edition of 23 November 2023 Srodowisko ogolne Probki gazowe General environment Gas samples Stezenie tlenu, azotu, dwutlenku wegla, metanu, tlenku wegla Zakres: tlen (0,05 – 22) % azot (4 – 100) % ditlenek wegla (0,05 – 50) % metan (0,05 – 100) % tlenek wegla (0,1 – 5) % wodor (1 – 4) % Metoda chromatografii gazowej z detekcja termokonduktometryczna (GC-TCD) Concentration of oxygen, nitrogen, carbon dioxide, methane, carbon monoxide, ethane, ethylene Range: oxygen (0,05 – 22) % nitrogen (4 – 100) % carbon dioxide (0,05 – 50) % methane (0,05 – 100) % carbon monoxide (0,1 – 5) % hydrogen (1 – 4) % Gas chromatography method with thermal conductivity detector (GC-TCD) Procedura BD-3/ZLGIG/PB-TL.05 edycja 4 z dnia 23.11.2023 r. Procedure BD-3/ZLGIG/PB-TL.05 4th edition of 23 November 2023","categories":["environment"],"row_index":120,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment Gas samples Concentration of oxygen, nitrogen, carbon dioxide, methane, carbon monoxide, ethane, ethylene Range: oxygen (0,05 – 22) % nitrogen (4 – 100) % carbon dioxide (0,05 – 50) % methane (0,05 – 100) % carbon monoxide (0,1 – 5) % hydrogen (1 – 4) % Gas chromatography method with thermal conductivity detector (GC-TCD) Procedura BD-3/ZLGIG/PB-TL.05 edycja 4 z dnia 23.11.2023 r. Procedure BD-3/ZLGIG/PB-TL.05 4th edition of 23 November 2023","search_zh":"一般环境 气体样品 General environment Gas samples Procedura BD-3/ZLGIG/PB-TL.05 edycja 4 z dnia 23.11.2023 r. Procedure BD-3/ZLGIG/PB-TL.05 4th edition of 23 November 2023","test_object_zh":"一般环境 气体样品 General environment Gas samples"},{"_id":"6a5a55ef9af9f73f38250b15","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Środowisko ogólne Próbki gazowe General environment Gas samples","test_object_en":"General environment Gas samples","methodology":"Stężenie wodoru Zakres: (0,5 – 10000) ppm Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) Concentration of hydrogen Range: (0,5 – 10000) ppm Gas chromatography method with thermal conductivity detector (GC-TCD)","methodology_en":"Concentration of hydrogen Range: (0,5 – 10000) ppm Gas chromatography method with thermal conductivity detector (GC-TCD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie wodoru Zakres: (0,5 – 10000) ppm Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) Concentration of hydrogen Range: (0,5 – 10000) ppm Gas chromatography method with thermal conductivity detector (GC-TCD)","reference":"Procedura BD-3/ZLGIG/PB-WO.06 edycja 4 z dnia 06.11.2023 r. Procedure BD-3/ZLGIG/PB-WO.06 4th edition of 6 November 2023","norm_bases":["Procedura BD-3/ZLGIG/PB-WO.06 edycja 4 z dnia 06.11.2023 r. Procedure BD-3/ZLGIG/PB-WO.06 4th edition of 6 November 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne Próbki gazowe General environment Gas samples Stężenie wodoru Zakres: (0,5 – 10000) ppm Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) Concentration of hydrogen Range: (0,5 – 10000) ppm Gas chromatography method with thermal conductivity detector (GC-TCD) Procedura BD-3/ZLGIG/PB-WO.06 edycja 4 z dnia 06.11.2023 r. Procedure BD-3/ZLGIG/PB-WO.06 4th edition of 6 November 2023 Srodowisko ogolne Probki gazowe General environment Gas samples Stezenie wodoru Zakres: (0,5 – 10000) ppm Metoda chromatografii gazowej z detekcja termokonduktometryczna (GC-TCD) Concentration of hydrogen Range: (0,5 – 10000) ppm Gas chromatography method with thermal conductivity detector (GC-TCD) Procedura BD-3/ZLGIG/PB-WO.06 edycja 4 z dnia 06.11.2023 r. Procedure BD-3/ZLGIG/PB-WO.06 4th edition of 6 November 2023","categories":["environment"],"row_index":121,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment Gas samples Concentration of hydrogen Range: (0,5 – 10000) ppm Gas chromatography method with thermal conductivity detector (GC-TCD) Procedura BD-3/ZLGIG/PB-WO.06 edycja 4 z dnia 06.11.2023 r. Procedure BD-3/ZLGIG/PB-WO.06 4th edition of 6 November 2023","search_zh":"一般环境 气体样品 General environment Gas samples Procedura BD-3/ZLGIG/PB-WO.06 edycja 4 z dnia 06.11.2023 r. Procedure BD-3/ZLGIG/PB-WO.06 4th edition of 6 November 2023","test_object_zh":"一般环境 气体样品 General environment Gas samples"},{"_id":"6a5a55ef9af9f73f38250b16","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Środowisko ogólne Próbki gazowe General environment Gas samples","test_object_en":"General environment Gas samples","methodology":"Stężenie węglowodorów nienasyconych: acetylenu i etylenu Zakres: acetylen (0,001 – 3) ppm etylen (0,01 – 3) ppm Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Concentration of unsaturated hydrocarbons: acetylene and ethylene Range: acetylene (0,001 – 3) ppm ethylene (0,01 – 3) ppm Gas chromatography method with flame ionization detection (GC-FID)","methodology_en":"Concentration of unsaturated hydrocarbons: acetylene and ethylene Range: acetylene (0,001 – 3) ppm ethylene (0,01 – 3) ppm Gas chromatography method with flame ionization detection (GC-FID)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie węglowodorów nienasyconych: acetylenu i etylenu Zakres: acetylen (0,001 – 3) ppm etylen (0,01 – 3) ppm Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Concentration of unsaturated hydrocarbons: acetylene and ethylene Range: acetylene (0,001 – 3) ppm ethylene (0,01 – 3) ppm Gas chromatography method with flame ionization detection (GC-FID)","reference":"Procedura BD-3/ZLGIG/PB-AE.07 edycja 3 z dnia 06.11.2023 r. Procedure BD-3/ZLGIG/PB-AE.07 3rd edition of 6 November 2023","norm_bases":["Procedura BD-3/ZLGIG/PB-AE.07 edycja 3 z dnia 06.11.2023 r. Procedure BD-3/ZLGIG/PB-AE.07 3rd edition of 6 November 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne Próbki gazowe General environment Gas samples Stężenie węglowodorów nienasyconych: acetylenu i etylenu Zakres: acetylen (0,001 – 3) ppm etylen (0,01 – 3) ppm Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Concentration of unsaturated hydrocarbons: acetylene and ethylene Range: acetylene (0,001 – 3) ppm ethylene (0,01 – 3) ppm Gas chromatography method with flame ionization detection (GC-FID) Procedura BD-3/ZLGIG/PB-AE.07 edycja 3 z dnia 06.11.2023 r. Procedure BD-3/ZLGIG/PB-AE.07 3rd edition of 6 November 2023 Srodowisko ogolne Probki gazowe General environment Gas samples Stezenie weglowodorow nienasyconych: acetylenu i etylenu Zakres: acetylen (0,001 – 3) ppm etylen (0,01 – 3) ppm Metoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Concentration of unsaturated hydrocarbons: acetylene and ethylene Range: acetylene (0,001 – 3) ppm ethylene (0,01 – 3) ppm Gas chromatography method with flame ionization detection (GC-FID) Procedura BD-3/ZLGIG/PB-AE.07 edycja 3 z dnia 06.11.2023 r. Procedure BD-3/ZLGIG/PB-AE.07 3rd edition of 6 November 2023","categories":["environment"],"row_index":122,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment Gas samples Concentration of unsaturated hydrocarbons: acetylene and ethylene Range: acetylene (0,001 – 3) ppm ethylene (0,01 – 3) ppm Gas chromatography method with flame ionization detection (GC-FID) Procedura BD-3/ZLGIG/PB-AE.07 edycja 3 z dnia 06.11.2023 r. Procedure BD-3/ZLGIG/PB-AE.07 3rd edition of 6 November 2023","search_zh":"一般环境 气体样品 General environment Gas samples Procedura BD-3/ZLGIG/PB-AE.07 edycja 3 z dnia 06.11.2023 r. Procedure BD-3/ZLGIG/PB-AE.07 3rd edition of 6 November 2023","test_object_zh":"一般环境 气体样品 General environment Gas samples"},{"_id":"6a5a55ef9af9f73f38250b17","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Środowisko ogólne Próbki gazowe General environment Gas samples","test_object_en":"General environment Gas samples","methodology":"Stężenie węglowodorów: etanu, etylenu, propanu, propylenu, acetylenu Zakres: etan (0,01 – 10000) ppm etylen (0,01 – 150) ppm propan (0,01 – 3000) ppm propylen (0,01 – 100) ppm acetylen (3 – 50) ppm Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Concentration of hydrocarbons: ethane, ethylene, propane, propylene, acetylene Range: ethane (0,01 – 10000) ppm ethylene (0,01 – 150) ppm propane (0,01 – 3000) ppm propylene (0,01 – 100) ppm acetylene (3 – 50) ppm Gas chromatography method with flame ionization detection (GC-FID)","methodology_en":"Concentration of hydrocarbons: ethane, ethylene, propane, propylene, acetylene Range: ethane (0,01 – 10000) ppm ethylene (0,01 – 150) ppm propane (0,01 – 3000) ppm propylene (0,01 – 100) ppm acetylene (3 – 50) ppm Gas chromatography method with flame ionization detection (GC-FID)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie węglowodorów: etanu, etylenu, propanu, propylenu, acetylenu Zakres: etan (0,01 – 10000) ppm etylen (0,01 – 150) ppm propan (0,01 – 3000) ppm propylen (0,01 – 100) ppm acetylen (3 – 50) ppm Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Concentration of hydrocarbons: ethane, ethylene, propane, propylene, acetylene Range: ethane (0,01 – 10000) ppm ethylene (0,01 – 150) ppm propane (0,01 – 3000) ppm propylene (0,01 – 100) ppm acetylene (3 – 50) ppm Gas chromatography method with flame ionization detection (GC-FID)","reference":"Procedura BD-3/ZLGIG/PB-WN.08 edycja 4 z dnia 06.11.2023 r. Procedure BD-3/ZLGIG/PB-WN.08 4th edition of 6 November 2023","norm_bases":["Procedura BD-3/ZLGIG/PB-WN.08 edycja 4 z dnia 06.11.2023 r. Procedure BD-3/ZLGIG/PB-WN.08 4th edition of 6 November 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne Próbki gazowe General environment Gas samples Stężenie węglowodorów: etanu, etylenu, propanu, propylenu, acetylenu Zakres: etan (0,01 – 10000) ppm etylen (0,01 – 150) ppm propan (0,01 – 3000) ppm propylen (0,01 – 100) ppm acetylen (3 – 50) ppm Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Concentration of hydrocarbons: ethane, ethylene, propane, propylene, acetylene Range: ethane (0,01 – 10000) ppm ethylene (0,01 – 150) ppm propane (0,01 – 3000) ppm propylene (0,01 – 100) ppm acetylene (3 – 50) ppm Gas chromatography method with flame ionization detection (GC-FID) Procedura BD-3/ZLGIG/PB-WN.08 edycja 4 z dnia 06.11.2023 r. Procedure BD-3/ZLGIG/PB-WN.08 4th edition of 6 November 2023 Srodowisko ogolne Probki gazowe General environment Gas samples Stezenie weglowodorow: etanu, etylenu, propanu, propylenu, acetylenu Zakres: etan (0,01 – 10000) ppm etylen (0,01 – 150) ppm propan (0,01 – 3000) ppm propylen (0,01 – 100) ppm acetylen (3 – 50) ppm Metoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Concentration of hydrocarbons: ethane, ethylene, propane, propylene, acetylene Range: ethane (0,01 – 10000) ppm ethylene (0,01 – 150) ppm propane (0,01 – 3000) ppm propylene (0,01 – 100) ppm acetylene (3 – 50) ppm Gas chromatography method with flame ionization detection (GC-FID) Procedura BD-3/ZLGIG/PB-WN.08 edycja 4 z dnia 06.11.2023 r. Procedure BD-3/ZLGIG/PB-WN.08 4th edition of 6 November 2023","categories":["environment"],"row_index":123,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment Gas samples Concentration of hydrocarbons: ethane, ethylene, propane, propylene, acetylene Range: ethane (0,01 – 10000) ppm ethylene (0,01 – 150) ppm propane (0,01 – 3000) ppm propylene (0,01 – 100) ppm acetylene (3 – 50) ppm Gas chromatography method with flame ionization detection (GC-FID) Procedura BD-3/ZLGIG/PB-WN.08 edycja 4 z dnia 06.11.2023 r. Procedure BD-3/ZLGIG/PB-WN.08 4th edition of 6 November 2023","search_zh":"一般环境 气体样品 General environment Gas samples Procedura BD-3/ZLGIG/PB-WN.08 edycja 4 z dnia 06.11.2023 r. Procedure BD-3/ZLGIG/PB-WN.08 4th edition of 6 November 2023","test_object_zh":"一般环境 气体样品 General environment Gas samples"},{"_id":"6a5a55ef9af9f73f38250b18","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: Węgiel kamienny Solid fuels: Hard coal","test_object_en":"Solid fuels: Hard coal","methodology":"Powierzchnia właściwa Zakres: (0,01 – 1000) m2/g Metoda sorpcji gazów Specific surface area Range: (0,01 – 1000) m2/g Gas sorption method","methodology_en":"Specific surface area Range: (0,01 – 1000) m2/g Gas sorption method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Powierzchnia właściwa Zakres: (0,01 – 1000) m2/g Metoda sorpcji gazów Specific surface area Range: (0,01 – 1000) m2/g Gas sorption method","reference":"PN-ISO 9277:2000","norm_bases":["PN-ISO 9277:2000"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: Węgiel kamienny Solid fuels: Hard coal Powierzchnia właściwa Zakres: (0,01 – 1000) m2/g Metoda sorpcji gazów Specific surface area Range: (0,01 – 1000) m2/g Gas sorption method PN-ISO 9277:2000 Paliwa stale: Wegiel kamienny Solid fuels: Hard coal Powierzchnia wlasciwa Zakres: (0,01 – 1000) m2/g Metoda sorpcji gazow Specific surface area Range: (0,01 – 1000) m2/g Gas sorption method PN-ISO 9277:2000","categories":["petro"],"row_index":124,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: Hard coal Specific surface area Range: (0,01 – 1000) m2/g Gas sorption method PN-ISO 9277:2000"},{"_id":"6a5a55ef9af9f73f38250b19","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Środowisko ogólne","test_object_en":"General environment","methodology":"Równoważny poziom dźwięku A,","methodology_en":"A-weighted equivalent sound level,","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A,","reference":"Załącznik nr 3 do Rozporządzenia","norm_bases":["Załącznik nr 3 do Rozporządzenia"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne Równoważny poziom dźwięku A, Załącznik nr 3 do Rozporządzenia Srodowisko ogolne Rownowazny poziom dzwieku A, Zalacznik nr 3 do Rozporzadzenia","categories":["environment"],"row_index":125,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment A-weighted equivalent sound level, Załącznik nr 3 do Rozporządzenia","search_zh":"一般环境 A 计权等效声级， Załącznik nr 3 do Rozporządzenia","test_object_zh":"一般环境","methodology_zh":"A 计权等效声级，"},{"_id":"6a5a55ef9af9f73f38250b1a","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"− hałas pochodzący od dróg,","test_object_en":"− hałas pochodzący od dróg,","methodology":"Ekspozycyjny poziom dźwięku A;","methodology_en":"A-weighted sound exposure level;","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ekspozycyjny poziom dźwięku A;","reference":"Ministra Środowiska z dnia","norm_bases":["Ministra Środowiska z dnia"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"− hałas pochodzący od dróg, Ekspozycyjny poziom dźwięku A; Ministra Środowiska z dnia − halas pochodzacy od drog, Ekspozycyjny poziom dzwieku A; Ministra Srodowiska z dnia","categories":["environment"],"row_index":126,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"− hałas pochodzący od dróg, A-weighted sound exposure level; Ministra Środowiska z dnia"},{"_id":"6a5a55ef9af9f73f38250b1b","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"linii kolejowych, linii tramwajowych","test_object_en":"of railway lines, tram lines","methodology":"Zakres: (24 – 130) dB","methodology_en":"Range: (24 – 130) dB","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zakres: (24 – 130) dB","reference":"16.06.2011 r. (Dz.U.nr 140, poz. 824","norm_bases":["16.06.2011 r. (Dz.U.nr 140, poz. 824"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"linii kolejowych, linii tramwajowych Zakres: (24 – 130) dB 16.06.2011 r. (Dz.U.nr 140, poz. 824 linii kolejowych, linii tramwajowych Zakres: (24 – 130) dB 16.06.2011 r. (Dz.U.nr 140, poz. 824","categories":["other"],"row_index":127,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"of railway lines, tram lines Range: (24 – 130) dB 16.06.2011 r. (Dz.U.nr 140, poz. 824","methodology_zh":"范围：(24 – 130) dB","search_zh":"范围：(24 – 130) dB 16.06.2011 r. (Dz.U.nr 140, poz. 824"},{"_id":"6a5a55ef9af9f73f38250b1c","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"General environment","test_object_en":"General environment","methodology":"Metoda pomiarowa bezpośrednia","methodology_en":"Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Metoda pomiarowa bezpośrednia","reference":"i nr 288, poz. 1697)","norm_bases":["i nr 288, poz. 1697)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"General environment Metoda pomiarowa bezpośrednia i nr 288, poz. 1697) General environment Metoda pomiarowa bezposrednia i nr 288, poz. 1697)","categories":["environment"],"row_index":128,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment Direct measurement method i nr 288, poz. 1697)","methodology_zh":"直接测量法","search_zh":"一般环境 / General environment 直接测量法 i nr 288, poz. 1697)","test_object_zh":"一般环境 / General environment"},{"_id":"6a5a55ef9af9f73f38250b1d","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"General environment","test_object_en":"General environment","methodology":"Metoda obliczeniowa","methodology_en":"Calculation method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Metoda obliczeniowa","reference":"Annex No. 3 to the Regulation of the","norm_bases":["Annex No. 3 to the Regulation of the"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"General environment Metoda obliczeniowa Annex No. 3 to the Regulation of the General environment Metoda obliczeniowa Annex No. 3 to the Regulation of the","categories":["environment"],"row_index":129,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment Calculation method Annex No. 3 to the Regulation of the","methodology_zh":"计算法","search_zh":"一般环境 / General environment 计算法 Annex No. 3 to the Regulation of the","test_object_zh":"一般环境 / General environment"},{"_id":"6a5a55ef9af9f73f38250b1e","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"– noise from roads, railways,","test_object_en":"– noise from roads, railways,","methodology":"Equivalent sound level A,","methodology_en":"Equivalent sound level A,","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Equivalent sound level A,","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"– noise from roads, railways, Equivalent sound level A, – noise from roads, railways, Equivalent sound level A,","categories":["environment"],"row_index":130,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"– noise from roads, railways, Equivalent sound level A,"},{"_id":"6a5a55ef9af9f73f38250b1f","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"tramlines","test_object_en":"tramlines","methodology":"Exposure sound level A;","methodology_en":"Exposure sound level A;","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Exposure sound level A;","reference":"2011","norm_bases":["2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"tramlines Exposure sound level A; 2011 tramlines Exposure sound level A; 2011","categories":["other"],"row_index":131,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"tramlines Exposure sound level A; 2011","search_zh":"有轨电车线路 / tramlines 2011","test_object_zh":"有轨电车线路 / tramlines"},{"_id":"6a5a55ef9af9f73f38250b20","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"tramlines","test_object_en":"tramlines","methodology":"Range: (24 – 130) dB","methodology_en":"Range: (24 – 130) dB","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Range: (24 – 130) dB","reference":"(Journal of Laws No. 140, item 824","norm_bases":["(Journal of Laws No. 140, item 824"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"tramlines Range: (24 – 130) dB (Journal of Laws No. 140, item 824 tramlines Range: (24 – 130) dB (Journal of Laws No. 140, item 824","categories":["other"],"row_index":132,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"tramlines Range: (24 – 130) dB (Journal of Laws No. 140, item 824","search_zh":"有轨电车线路 / tramlines (Journal of Laws No. 140, item 824","test_object_zh":"有轨电车线路 / tramlines"},{"_id":"6a5a55ef9af9f73f38250b21","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"tramlines","test_object_en":"tramlines","methodology":"Direct measurement method","methodology_en":"Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Direct measurement method","reference":"and No. 288, item 1697)","norm_bases":["and No. 288, item 1697)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"tramlines Direct measurement method and No. 288, item 1697) tramlines Direct measurement method and No. 288, item 1697)","categories":["other"],"row_index":133,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"tramlines Direct measurement method and No. 288, item 1697)","methodology_zh":"直接测量法 / Direct measurement method","search_zh":"有轨电车线路 / tramlines 直接测量法 / Direct measurement method and No. 288, item 1697)","test_object_zh":"有轨电车线路 / tramlines"},{"_id":"6a5a55ef9af9f73f38250b22","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"tramlines","test_object_en":"tramlines","methodology":"Calculation method","methodology_en":"Calculation method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Calculation method","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"tramlines Calculation method tramlines Calculation method","categories":["other"],"row_index":134,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"tramlines Calculation method","search_zh":"有轨电车线路 / tramlines","test_object_zh":"有轨电车线路 / tramlines"},{"_id":"6a5a55ef9af9f73f38250b23","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"tramlines","test_object_en":"tramlines","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN","methodology_en":"Equivalent A-weighted sound level for the reference time T expressed by the indicators LAeqD and LAeqN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"tramlines Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN tramlines Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN","categories":["other"],"row_index":135,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"tramlines Equivalent A-weighted sound level for the reference time T expressed by the indicators LAeqD and LAeqN","methodology_zh":"以 LAeqD 与 LAeqN 指标表示的参考时段 T 内的 A 计权等效声级","search_zh":"有轨电车线路 / tramlines 以 LAeqD 与 LAeqN 指标表示的参考时段 T 内的 A 计权等效声级","test_object_zh":"有轨电车线路 / tramlines"},{"_id":"6a5a55ef9af9f73f38250b24","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"tramlines","test_object_en":"tramlines","methodology":"(z obliczeń)","methodology_en":"(calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"(z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"tramlines (z obliczeń) tramlines (z obliczen)","categories":["other"],"row_index":136,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"tramlines (calculated)","methodology_zh":"（计算得出）","search_zh":"有轨电车线路 / tramlines （计算得出）","test_object_zh":"有轨电车线路 / tramlines"},{"_id":"6a5a55ef9af9f73f38250b25","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"tramlines","test_object_en":"tramlines","methodology":"Equivalent A-weighted sound level for","methodology_en":"Equivalent A-weighted sound level for","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Equivalent A-weighted sound level for","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"tramlines Equivalent A-weighted sound level for tramlines Equivalent A-weighted sound level for","categories":["other"],"row_index":137,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"tramlines Equivalent A-weighted sound level for","search_zh":"有轨电车线路 / tramlines","test_object_zh":"有轨电车线路 / tramlines"},{"_id":"6a5a55ef9af9f73f38250b26","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"tramlines","test_object_en":"tramlines","methodology":"the reference time T expressed by the","methodology_en":"the reference time T expressed by the","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"the reference time T expressed by the","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"tramlines the reference time T expressed by the tramlines the reference time T expressed by the","categories":["other"],"row_index":138,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"tramlines the reference time T expressed by the","search_zh":"有轨电车线路 / tramlines","test_object_zh":"有轨电车线路 / tramlines"},{"_id":"6a5a55ef9af9f73f38250b27","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"tramlines","test_object_en":"tramlines","methodology":"indicators L and L (from AeqD AeqN","methodology_en":"indicators L and L (from AeqD AeqN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"indicators L and L (from AeqD AeqN","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"tramlines indicators L and L (from AeqD AeqN tramlines indicators L and L (from AeqD AeqN","categories":["other"],"row_index":139,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"tramlines indicators L and L (from AeqD AeqN","search_zh":"有轨电车线路 / tramlines","test_object_zh":"有轨电车线路 / tramlines"},{"_id":"6a5a55ef9af9f73f38250b28","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"tramlines","test_object_en":"tramlines","methodology":"calculations)","methodology_en":"calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"calculations)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"tramlines calculations) tramlines calculations)","categories":["other"],"row_index":140,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"tramlines calculations)","search_zh":"有轨电车线路 / tramlines","test_object_zh":"有轨电车线路 / tramlines"},{"_id":"6a5a55ef9af9f73f38250b29","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Środowisko ogólne","test_object_en":"General environment","methodology":"Równoważny poziom dźwięku A","methodology_en":"A-weighted equivalent sound pressure level","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A","reference":"PN-ISO 10847:2002","norm_bases":["PN-ISO 10847:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne Równoważny poziom dźwięku A PN-ISO 10847:2002 Srodowisko ogolne Rownowazny poziom dzwieku A PN-ISO 10847:2002","categories":["environment"],"row_index":141,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment A-weighted equivalent sound pressure level PN-ISO 10847:2002","methodology_zh":"A 计权等效声级","search_zh":"一般环境 A 计权等效声级 PN-ISO 10847:2002","test_object_zh":"一般环境"},{"_id":"6a5a55ef9af9f73f38250b2a","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"− ekrany akustyczne „in situ”","test_object_en":"− noise barriers „in situ”","methodology":"Zakres: (24 – 130) dB","methodology_en":"Range: (24 – 130) dB","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zakres: (24 – 130) dB","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"− ekrany akustyczne „in situ” Zakres: (24 – 130) dB − ekrany akustyczne „in situ” Zakres: (24 – 130) dB","categories":["other"],"row_index":142,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"− noise barriers „in situ” Range: (24 – 130) dB","methodology_zh":"范围：(24 – 130) dB","search_zh":"范围：(24 – 130) dB"},{"_id":"6a5a55ef9af9f73f38250b2b","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"General environment","test_object_en":"General environment","methodology":"Metoda pomiarowa bezpośrednia","methodology_en":"Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Metoda pomiarowa bezpośrednia","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"General environment Metoda pomiarowa bezpośrednia General environment Metoda pomiarowa bezposrednia","categories":["environment"],"row_index":143,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment Direct measurement method","methodology_zh":"直接测量法","search_zh":"一般环境 / General environment 直接测量法","test_object_zh":"一般环境 / General environment"},{"_id":"6a5a55ef9af9f73f38250b2c","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"General environment","test_object_en":"General environment","methodology":"Equivalent sound level A","methodology_en":"Equivalent sound level A","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Equivalent sound level A","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"General environment Equivalent sound level A General environment Equivalent sound level A","categories":["environment"],"row_index":144,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment Equivalent sound level A","search_zh":"一般环境 / General environment","test_object_zh":"一般环境 / General environment"},{"_id":"6a5a55ef9af9f73f38250b2d","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"– noise barriers ”in situ”","test_object_en":"– noise barriers ”in situ”","methodology":"Range: (24 – 130) dB","methodology_en":"Range: (24 – 130) dB","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Range: (24 – 130) dB","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"– noise barriers ”in situ” Range: (24 – 130) dB – noise barriers ”in situ” Range: (24 – 130) dB","categories":["environment"],"row_index":145,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"– noise barriers ”in situ” Range: (24 – 130) dB","search_zh":"－ 声屏障「现场」/ noise barriers ”in situ”","test_object_zh":"－ 声屏障「现场」/ noise barriers ”in situ”"},{"_id":"6a5a55ef9af9f73f38250b2e","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"– noise barriers ”in situ”","test_object_en":"– noise barriers ”in situ”","methodology":"Direct measurement method","methodology_en":"Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Direct measurement method","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"– noise barriers ”in situ” Direct measurement method – noise barriers ”in situ” Direct measurement method","categories":["environment"],"row_index":146,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"– noise barriers ”in situ” Direct measurement method","methodology_zh":"直接测量法 / Direct measurement method","search_zh":"－ 声屏障「现场」/ noise barriers ”in situ” 直接测量法 / Direct measurement method","test_object_zh":"－ 声屏障「现场」/ noise barriers ”in situ”"},{"_id":"6a5a55ef9af9f73f38250b2f","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"– noise barriers ”in situ”","test_object_en":"– noise barriers ”in situ”","methodology":"Skuteczność ekranów","methodology_en":"Efficiency of screens","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność ekranów","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"– noise barriers ”in situ” Skuteczność ekranów – noise barriers ”in situ” Skutecznosc ekranow","categories":["environment"],"row_index":147,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"– noise barriers ”in situ” Efficiency of screens","search_zh":"－ 声屏障「现场」/ noise barriers ”in situ”","test_object_zh":"－ 声屏障「现场」/ noise barriers ”in situ”"},{"_id":"6a5a55ef9af9f73f38250b30","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"– noise barriers ”in situ”","test_object_en":"– noise barriers ”in situ”","methodology":"(z obliczeń)","methodology_en":"(calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"(z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"– noise barriers ”in situ” (z obliczeń) – noise barriers ”in situ” (z obliczen)","categories":["environment"],"row_index":148,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"– noise barriers ”in situ” (calculated)","methodology_zh":"（计算得出）","search_zh":"－ 声屏障「现场」/ noise barriers ”in situ” （计算得出）","test_object_zh":"－ 声屏障「现场」/ noise barriers ”in situ”"},{"_id":"6a5a55ef9af9f73f38250b31","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"– noise barriers ”in situ”","test_object_en":"– noise barriers ”in situ”","methodology":"Screening effectiveness","methodology_en":"Screening effectiveness","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Screening effectiveness","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"– noise barriers ”in situ” Screening effectiveness – noise barriers ”in situ” Screening effectiveness","categories":["environment"],"row_index":149,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"– noise barriers ”in situ” Screening effectiveness","search_zh":"－ 声屏障「现场」/ noise barriers ”in situ”","test_object_zh":"－ 声屏障「现场」/ noise barriers ”in situ”"},{"_id":"6a5a55ef9af9f73f38250b32","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"– noise barriers ”in situ”","test_object_en":"– noise barriers ”in situ”","methodology":"(calculated)","methodology_en":"(calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"(calculated)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"– noise barriers ”in situ” (calculated) – noise barriers ”in situ” (calculated)","categories":["environment"],"row_index":150,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"– noise barriers ”in situ” (calculated)","search_zh":"－ 声屏障「现场」/ noise barriers ”in situ”","test_object_zh":"－ 声屏障「现场」/ noise barriers ”in situ”"},{"_id":"6a5a55ef9af9f73f38250b33","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Maszyny i urządzenia – hałas","test_object_en":"Machinery and equipment – noise","methodology":"Poziom ciśnienia akustycznego skorygowany charakterystyką częstotliwościową A","methodology_en":"A-frequency-weighted sound pressure level","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom ciśnienia akustycznego skorygowany charakterystyką częstotliwościową A","reference":"PN-EN ISO 3744:2011","norm_bases":["PN-EN ISO 3744:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Maszyny i urządzenia – hałas Poziom ciśnienia akustycznego skorygowany charakterystyką częstotliwościową A PN-EN ISO 3744:2011 Maszyny i urzadzenia – halas Poziom cisnienia akustycznego skorygowany charakterystyka czestotliwosciowa A PN-EN ISO 3744:2011","categories":["environment"],"row_index":151,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Machinery and equipment – noise A-frequency-weighted sound pressure level PN-EN ISO 3744:2011","search_zh":"机器与设备 – 噪声 PN-EN ISO 3744:2011","test_object_zh":"机器与设备 – 噪声"},{"_id":"6a5a55ef9af9f73f38250b34","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Machinery and equipment – noise","test_object_en":"Machinery and equipment – noise","methodology":"Poziom ciśnienia akustycznego pojedynczego zdarzenia skorygowany charakterystyką częstotliwościową A","methodology_en":"A-weighted single event sound pressure level","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom ciśnienia akustycznego pojedynczego zdarzenia skorygowany charakterystyką częstotliwościową A","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Machinery and equipment – noise Poziom ciśnienia akustycznego pojedynczego zdarzenia skorygowany charakterystyką częstotliwościową A Machinery and equipment – noise Poziom cisnienia akustycznego pojedynczego zdarzenia skorygowany charakterystyka czestotliwosciowa A","categories":["environment"],"row_index":152,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Machinery and equipment – noise A-weighted single event sound pressure level","search_zh":"机器与设备 － 噪声 / Machinery and equipment – noise","test_object_zh":"机器与设备 － 噪声 / Machinery and equipment – noise"},{"_id":"6a5a55ef9af9f73f38250b35","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Machinery and equipment – noise","test_object_en":"Machinery and equipment – noise","methodology":"Zakres: (24 – 130) dB","methodology_en":"Range: (24 – 130) dB","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zakres: (24 – 130) dB","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Machinery and equipment – noise Zakres: (24 – 130) dB Machinery and equipment – noise Zakres: (24 – 130) dB","categories":["environment"],"row_index":153,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Machinery and equipment – noise Range: (24 – 130) dB","search_zh":"机器与设备 － 噪声 / Machinery and equipment – noise 范围：(24 – 130) dB","test_object_zh":"机器与设备 － 噪声 / Machinery and equipment – noise","methodology_zh":"范围：(24 – 130) dB"},{"_id":"6a5a55ef9af9f73f38250b36","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Machinery and equipment – noise","test_object_en":"Machinery and equipment – noise","methodology":"Metoda pomiarowa bezpośrednia","methodology_en":"Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Metoda pomiarowa bezpośrednia","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Machinery and equipment – noise Metoda pomiarowa bezpośrednia Machinery and equipment – noise Metoda pomiarowa bezposrednia","categories":["environment"],"row_index":154,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Machinery and equipment – noise Direct measurement method","methodology_zh":"直接测量法","search_zh":"机器与设备 － 噪声 / Machinery and equipment – noise 直接测量法","test_object_zh":"机器与设备 － 噪声 / Machinery and equipment – noise"},{"_id":"6a5a55ef9af9f73f38250b37","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Machinery and equipment – noise","test_object_en":"Machinery and equipment – noise","methodology":"Metoda techniczna","methodology_en":"Technical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Metoda techniczna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Machinery and equipment – noise Metoda techniczna Machinery and equipment – noise Metoda techniczna","categories":["environment"],"row_index":155,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Machinery and equipment – noise Technical method","search_zh":"机器与设备 － 噪声 / Machinery and equipment – noise 工程法","test_object_zh":"机器与设备 － 噪声 / Machinery and equipment – noise","methodology_zh":"工程法"},{"_id":"6a5a55ef9af9f73f38250b38","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Machinery and equipment – noise","test_object_en":"Machinery and equipment – noise","methodology":"Metoda orientacyjna","methodology_en":"Indicative method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Metoda orientacyjna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Machinery and equipment – noise Metoda orientacyjna Machinery and equipment – noise Metoda orientacyjna","categories":["environment"],"row_index":156,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Machinery and equipment – noise Indicative method","search_zh":"机器与设备 － 噪声 / Machinery and equipment – noise 定向法","test_object_zh":"机器与设备 － 噪声 / Machinery and equipment – noise","methodology_zh":"定向法"},{"_id":"6a5a55ef9af9f73f38250b39","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Machinery and equipment – noise","test_object_en":"Machinery and equipment – noise","methodology":"Sound pressure level corrected by A- frequency weighting Single event sound pressure level corrected by A-frequency weighting Range: (24 – 130) dB Direct measurement method Technical method","methodology_en":"Sound pressure level corrected by A- frequency weighting Single event sound pressure level corrected by A-frequency weighting Range: (24 – 130) dB Direct measurement method Technical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sound pressure level corrected by A- frequency weighting Single event sound pressure level corrected by A-frequency weighting Range: (24 – 130) dB Direct measurement method Technical method","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Machinery and equipment – noise Sound pressure level corrected by A- frequency weighting Single event sound pressure level corrected by A-frequency weighting Range: (24 – 130) dB Direct measurement method Technical method Machinery and equipment – noise Sound pressure level corrected by A- frequency weighting Single event sound pressure level corrected by A-frequency weighting Range: (24 – 130) dB Direct measurement method Technical method","categories":["environment"],"row_index":157,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Machinery and equipment – noise Sound pressure level corrected by A- frequency weighting Single event sound pressure level corrected by A-frequency weighting Range: (24 – 130) dB Direct measurement method Technical method","search_zh":"机器与设备 － 噪声 / Machinery and equipment – noise","test_object_zh":"机器与设备 － 噪声 / Machinery and equipment – noise"},{"_id":"6a5a55ef9af9f73f38250b3a","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Machinery and equipment – noise","test_object_en":"Machinery and equipment – noise","methodology":"Indicative method","methodology_en":"Indicative method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indicative method","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Machinery and equipment – noise Indicative method Machinery and equipment – noise Indicative method","categories":["environment"],"row_index":158,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Machinery and equipment – noise Indicative method","search_zh":"机器与设备 － 噪声 / Machinery and equipment – noise","test_object_zh":"机器与设备 － 噪声 / Machinery and equipment – noise"},{"_id":"6a5a55ef9af9f73f38250b3b","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Machinery and equipment – noise","test_object_en":"Machinery and equipment – noise","methodology":"Poziom mocy akustycznej","methodology_en":"Sound power level","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom mocy akustycznej","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Machinery and equipment – noise Poziom mocy akustycznej Machinery and equipment – noise Poziom mocy akustycznej","categories":["environment"],"row_index":159,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Machinery and equipment – noise Sound power level","search_zh":"机器与设备 － 噪声 / Machinery and equipment – noise","test_object_zh":"机器与设备 － 噪声 / Machinery and equipment – noise"},{"_id":"6a5a55ef9af9f73f38250b3c","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Machinery and equipment – noise","test_object_en":"Machinery and equipment – noise","methodology":"Poziom energii akustycznej","methodology_en":"Sound energy level","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom energii akustycznej","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Machinery and equipment – noise Poziom energii akustycznej Machinery and equipment – noise Poziom energii akustycznej","categories":["environment"],"row_index":160,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Machinery and equipment – noise Sound energy level","search_zh":"机器与设备 － 噪声 / Machinery and equipment – noise","test_object_zh":"机器与设备 － 噪声 / Machinery and equipment – noise"},{"_id":"6a5a55ef9af9f73f38250b3d","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Machinery and equipment – noise","test_object_en":"Machinery and equipment – noise","methodology":"(z obliczeń)","methodology_en":"(calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"(z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Machinery and equipment – noise (z obliczeń) Machinery and equipment – noise (z obliczen)","categories":["environment"],"row_index":161,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Machinery and equipment – noise (calculated)","methodology_zh":"（计算得出）","search_zh":"机器与设备 － 噪声 / Machinery and equipment – noise （计算得出）","test_object_zh":"机器与设备 － 噪声 / Machinery and equipment – noise"},{"_id":"6a5a55ef9af9f73f38250b3e","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Machinery and equipment – noise","test_object_en":"Machinery and equipment – noise","methodology":"Sound power level","methodology_en":"Sound power level","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sound power level","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Machinery and equipment – noise Sound power level Machinery and equipment – noise Sound power level","categories":["environment"],"row_index":162,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Machinery and equipment – noise Sound power level","search_zh":"机器与设备 － 噪声 / Machinery and equipment – noise","test_object_zh":"机器与设备 － 噪声 / Machinery and equipment – noise"},{"_id":"6a5a55ef9af9f73f38250b3f","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Machinery and equipment – noise","test_object_en":"Machinery and equipment – noise","methodology":"Sound energy level","methodology_en":"Sound energy level","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sound energy level","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Machinery and equipment – noise Sound energy level Machinery and equipment – noise Sound energy level","categories":["environment"],"row_index":163,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Machinery and equipment – noise Sound energy level","search_zh":"机器与设备 － 噪声 / Machinery and equipment – noise","test_object_zh":"机器与设备 － 噪声 / Machinery and equipment – noise"},{"_id":"6a5a55ef9af9f73f38250b40","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Machinery and equipment – noise","test_object_en":"Machinery and equipment – noise","methodology":"(calculated)","methodology_en":"(calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"(calculated)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Machinery and equipment – noise (calculated) Machinery and equipment – noise (calculated)","categories":["environment"],"row_index":164,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Machinery and equipment – noise (calculated)","search_zh":"机器与设备 － 噪声 / Machinery and equipment – noise","test_object_zh":"机器与设备 － 噪声 / Machinery and equipment – noise"},{"_id":"6a5a55ef9af9f73f38250b41","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Taśmy przenośnikowe","test_object_en":"Conveyor belts","methodology":"Rezystancja powierzchniowa Wartość rezystancji od 1x103 Ω do 1x1012 Ω","methodology_en":"Surface resistance Resistance value from 1x103 Ω to 1x1012 Ω","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja powierzchniowa Wartość rezystancji od 1x103 Ω do 1x1012 Ω","reference":"PN-EN ISO 284:2013","norm_bases":["PN-EN ISO 284:2013"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Taśmy przenośnikowe Rezystancja powierzchniowa Wartość rezystancji od 1x103 Ω do 1x1012 Ω PN-EN ISO 284:2013 Tasmy przenosnikowe Rezystancja powierzchniowa Wartosc rezystancji od 1x103 Ω do 1x1012 Ω PN-EN ISO 284:2013","categories":["other"],"row_index":165,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Conveyor belts Surface resistance Resistance value from 1x103 Ω to 1x1012 Ω PN-EN ISO 284:2013","search_zh":"输送带 PN-EN ISO 284:2013","test_object_zh":"输送带"},{"_id":"6a5a55ef9af9f73f38250b42","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Conveyor belts","test_object_en":"Conveyor belts","methodology":"Wartość napięcia do 600 V","methodology_en":"Voltage value up to 600 V","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wartość napięcia do 600 V","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Conveyor belts Wartość napięcia do 600 V Conveyor belts Wartosc napiecia do 600 V","categories":["other"],"row_index":166,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Conveyor belts Voltage value up to 600 V","search_zh":"输送带 / Conveyor belts","test_object_zh":"输送带 / Conveyor belts"},{"_id":"6a5a55ef9af9f73f38250b43","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Conveyor belts","test_object_en":"Conveyor belts","methodology":"Surface resistance Resistance value from 1x103 Ω to 1x1012 Ω","methodology_en":"Surface resistance Resistance value from 1x103 Ω to 1x1012 Ω","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Surface resistance Resistance value from 1x103 Ω to 1x1012 Ω","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Conveyor belts Surface resistance Resistance value from 1x103 Ω to 1x1012 Ω Conveyor belts Surface resistance Resistance value from 1x103 Ω to 1x1012 Ω","categories":["other"],"row_index":167,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Conveyor belts Surface resistance Resistance value from 1x103 Ω to 1x1012 Ω","search_zh":"输送带 / Conveyor belts","test_object_zh":"输送带 / Conveyor belts"},{"_id":"6a5a55ef9af9f73f38250b44","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Conveyor belts","test_object_en":"Conveyor belts","methodology":"Voltage value up to 600 V","methodology_en":"Voltage value up to 600 V","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Voltage value up to 600 V","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Conveyor belts Voltage value up to 600 V Conveyor belts Voltage value up to 600 V","categories":["other"],"row_index":168,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Conveyor belts Voltage value up to 600 V","search_zh":"输送带 / Conveyor belts","test_object_zh":"输送带 / Conveyor belts"},{"_id":"6a5a55ef9af9f73f38250b45","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Materiały, wyroby i urządzenia","test_object_en":"Materials, products and equipment","methodology":"Rezystancja powierzchniowa Wartość rezystancji od 1x103 Ω do 1x1012 Ω Rezystywność powierzchniowa z obliczeń Surface resistance Resistance value from 1x103 Ω to 1x1012 Ω Surface resistivity from calculation","methodology_en":"Surface resistance Resistance value from 1x103 Ω to 1x1012 Ω Surface resistivity from calculation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja powierzchniowa Wartość rezystancji od 1x103 Ω do 1x1012 Ω Rezystywność powierzchniowa z obliczeń Surface resistance Resistance value from 1x103 Ω to 1x1012 Ω Surface resistivity from calculation","reference":"PN-EN 61340-2-3:2016 IEC 61340-4-10:2012 PN-EN IEC 60079-0:2018-09 PN-E-05203:1992 PN-EN 60079-32-2:2015-08","norm_bases":["PN-EN 61340-2-3:2016 IEC 61340-4-10:2012 PN-EN IEC 60079-0:2018-09 PN-E-05203:1992 PN-EN 60079-32-2:2015-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały, wyroby i urządzenia Rezystancja powierzchniowa Wartość rezystancji od 1x103 Ω do 1x1012 Ω Rezystywność powierzchniowa z obliczeń Surface resistance Resistance value from 1x103 Ω to 1x1012 Ω Surface resistivity from calculation PN-EN 61340-2-3:2016 IEC 61340-4-10:2012 PN-EN IEC 60079-0:2018-09 PN-E-05203:1992 PN-EN 60079-32-2:2015-08 Materialy, wyroby i urzadzenia Rezystancja powierzchniowa Wartosc rezystancji od 1x103 Ω do 1x1012 Ω Rezystywnosc powierzchniowa z obliczen Surface resistance Resistance value from 1x103 Ω to 1x1012 Ω Surface resistivity from calculation PN-EN 61340-2-3:2016 IEC 61340-4-10:2012 PN-EN IEC 60079-0:2018-09 PN-E-05203:1992 PN-EN 60079-32-2:2015-08","categories":["materials"],"row_index":169,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Materials, products and equipment Surface resistance Resistance value from 1x103 Ω to 1x1012 Ω Surface resistivity from calculation PN-EN 61340-2-3:2016 IEC 61340-4-10:2012 PN-EN IEC 60079-0:2018-09 PN-E-05203:1992 PN-EN 60079-32-2:2015-08"},{"_id":"6a5a55ef9af9f73f38250b46","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"and equipment","test_object_en":"and equipment","methodology":"Rezystancja skrośna Wartość rezystancji od 1x103 Ω do 1x1012 Ω Rezystywność skrośna z obliczeń (zakres grubości: 0,01-30 mm) Cross resistance Resistance value from 1x103 Ω to 1x1012 Ω Cross resistivity from calculation (thickness range: 0,01-30 mm)","methodology_en":"Cross resistance Resistance value from 1x103 Ω to 1x1012 Ω Cross resistivity from calculation (thickness range: 0,01-30 mm)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja skrośna Wartość rezystancji od 1x103 Ω do 1x1012 Ω Rezystywność skrośna z obliczeń (zakres grubości: 0,01-30 mm) Cross resistance Resistance value from 1x103 Ω to 1x1012 Ω Cross resistivity from calculation (thickness range: 0,01-30 mm)","reference":"PN-EN 61340-2-3:2016 PN-E-05203:1992 PN-EN 60079-32-2:2015-08","norm_bases":["PN-EN 61340-2-3:2016 PN-E-05203:1992 PN-EN 60079-32-2:2015-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"and equipment Rezystancja skrośna Wartość rezystancji od 1x103 Ω do 1x1012 Ω Rezystywność skrośna z obliczeń (zakres grubości: 0,01-30 mm) Cross resistance Resistance value from 1x103 Ω to 1x1012 Ω Cross resistivity from calculation (thickness range: 0,01-30 mm) PN-EN 61340-2-3:2016 PN-E-05203:1992 PN-EN 60079-32-2:2015-08 and equipment Rezystancja skrosna Wartosc rezystancji od 1x103 Ω do 1x1012 Ω Rezystywnosc skrosna z obliczen (zakres grubosci: 0,01-30 mm) Cross resistance Resistance value from 1x103 Ω to 1x1012 Ω Cross resistivity from calculation (thickness range: 0,01-30 mm) PN-EN 61340-2-3:2016 PN-E-05203:1992 PN-EN 60079-32-2:2015-08","categories":["other"],"row_index":170,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"and equipment Cross resistance Resistance value from 1x103 Ω to 1x1012 Ω Cross resistivity from calculation (thickness range: 0,01-30 mm) PN-EN 61340-2-3:2016 PN-E-05203:1992 PN-EN 60079-32-2:2015-08","search_zh":"与装备 / and equipment PN-EN 61340-2-3:2016 PN-E-05203:1992 PN-EN 60079-32-2:2015-08","test_object_zh":"与装备 / and equipment"},{"_id":"6a5a55ef9af9f73f38250b47","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"and equipment","test_object_en":"and equipment","methodology":"Rezystancja względem elementu uziemiającego Wartość rezystancji od 1x103 Ω do 1x1012 Ω Resistance to earth grounding element Resistance value from 1·103 Ω to 1·1012 Ω","methodology_en":"Resistance to earth grounding element Resistance value from 1·103 Ω to 1·1012 Ω","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja względem elementu uziemiającego Wartość rezystancji od 1x103 Ω do 1x1012 Ω Resistance to earth grounding element Resistance value from 1·103 Ω to 1·1012 Ω","reference":"PN-EN 61340-2-3:2016 PN-E-05203:1992 PN-EN 60079-32-2:2015-08","norm_bases":["PN-EN 61340-2-3:2016 PN-E-05203:1992 PN-EN 60079-32-2:2015-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"and equipment Rezystancja względem elementu uziemiającego Wartość rezystancji od 1x103 Ω do 1x1012 Ω Resistance to earth grounding element Resistance value from 1·103 Ω to 1·1012 Ω PN-EN 61340-2-3:2016 PN-E-05203:1992 PN-EN 60079-32-2:2015-08 and equipment Rezystancja wzgledem elementu uziemiajacego Wartosc rezystancji od 1x103 Ω do 1x1012 Ω Resistance to earth grounding element Resistance value from 1·103 Ω to 1·1012 Ω PN-EN 61340-2-3:2016 PN-E-05203:1992 PN-EN 60079-32-2:2015-08","categories":["other"],"row_index":171,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"and equipment Resistance to earth grounding element Resistance value from 1·103 Ω to 1·1012 Ω PN-EN 61340-2-3:2016 PN-E-05203:1992 PN-EN 60079-32-2:2015-08","search_zh":"与装备 / and equipment PN-EN 61340-2-3:2016 PN-E-05203:1992 PN-EN 60079-32-2:2015-08","test_object_zh":"与装备 / and equipment"},{"_id":"6a5a55ef9af9f73f38250b48","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"and equipment","test_object_en":"and equipment","methodology":"Rezystancja między punktami Wartość rezystancji od 1x103 Ω do 1x1012 Ω Point-to-point resistance Resistance value from 1x103 Ω to 1x1012 Ω","methodology_en":"Point-to-point resistance Resistance value from 1x103 Ω to 1x1012 Ω","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja między punktami Wartość rezystancji od 1x103 Ω do 1x1012 Ω Point-to-point resistance Resistance value from 1x103 Ω to 1x1012 Ω","reference":"PN-EN 61340-2-3:2016 IEC 61340-4-10:2012 PN-E-05203:1992 PN-EN 60079-32-2:2015-08","norm_bases":["PN-EN 61340-2-3:2016 IEC 61340-4-10:2012 PN-E-05203:1992 PN-EN 60079-32-2:2015-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"and equipment Rezystancja między punktami Wartość rezystancji od 1x103 Ω do 1x1012 Ω Point-to-point resistance Resistance value from 1x103 Ω to 1x1012 Ω PN-EN 61340-2-3:2016 IEC 61340-4-10:2012 PN-E-05203:1992 PN-EN 60079-32-2:2015-08 and equipment Rezystancja miedzy punktami Wartosc rezystancji od 1x103 Ω do 1x1012 Ω Point-to-point resistance Resistance value from 1x103 Ω to 1x1012 Ω PN-EN 61340-2-3:2016 IEC 61340-4-10:2012 PN-E-05203:1992 PN-EN 60079-32-2:2015-08","categories":["other"],"row_index":172,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"and equipment Point-to-point resistance Resistance value from 1x103 Ω to 1x1012 Ω PN-EN 61340-2-3:2016 IEC 61340-4-10:2012 PN-E-05203:1992 PN-EN 60079-32-2:2015-08","search_zh":"与装备 / and equipment PN-EN 61340-2-3:2016 IEC 61340-4-10:2012 PN-E-05203:1992 PN-EN 60079-32-2:2015-08","test_object_zh":"与装备 / and equipment"},{"_id":"6a5a55ef9af9f73f38250b49","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"and equipment","test_object_en":"and equipment","methodology":"Zdolność do elektryzacji Electrification capability","methodology_en":"Electrification capability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność do elektryzacji Electrification capability","reference":"PN-EN ISO 80079-36:2016-07","norm_bases":["PN-EN ISO 80079-36:2016-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"and equipment Zdolność do elektryzacji Electrification capability PN-EN ISO 80079-36:2016-07 and equipment Zdolnosc do elektryzacji Electrification capability PN-EN ISO 80079-36:2016-07","categories":["other"],"row_index":173,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"and equipment Electrification capability PN-EN ISO 80079-36:2016-07","search_zh":"与装备 / and equipment PN-EN ISO 80079-36:2016-07","test_object_zh":"与装备 / and equipment"},{"_id":"6a5a55ef9af9f73f38250b4a","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Układ obuwie i podłoga z udziałem","test_object_en":"Układ obuwie i podłoga z udziałem","methodology":"Rezystancja układu","methodology_en":"Resistance of the system","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja układu","reference":"PN-EN IEC 61340-4-5:2018-09","norm_bases":["PN-EN IEC 61340-4-5:2018-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Układ obuwie i podłoga z udziałem Rezystancja układu PN-EN IEC 61340-4-5:2018-09 Uklad obuwie i podloga z udzialem Rezystancja ukladu PN-EN IEC 61340-4-5:2018-09","categories":["other"],"row_index":174,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Układ obuwie i podłoga z udziałem Resistance of the system PN-EN IEC 61340-4-5:2018-09"},{"_id":"6a5a55ef9af9f73f38250b4b","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"człowieka","test_object_en":"human","methodology":"Wartość rezystancji","methodology_en":"Resistance value","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wartość rezystancji","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"człowieka Wartość rezystancji czlowieka Wartosc rezystancji","categories":["other"],"row_index":175,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"human Resistance value"},{"_id":"6a5a55ef9af9f73f38250b4c","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Footwear and flooring system","test_object_en":"Footwear and flooring system","methodology":"od 1x103 Ω do 1x1012 Ω","methodology_en":"from 1x103 Ω to 1x1012 Ω","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"od 1x103 Ω do 1x1012 Ω","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Footwear and flooring system od 1x103 Ω do 1x1012 Ω Footwear and flooring system od 1x103 Ω do 1x1012 Ω","categories":["other"],"row_index":176,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Footwear and flooring system from 1x103 Ω to 1x1012 Ω"},{"_id":"6a5a55ef9af9f73f38250b4d","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Footwear and flooring system","test_object_en":"Footwear and flooring system","methodology":"Resistance of the circuit","methodology_en":"Resistance of the circuit","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Resistance of the circuit","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Footwear and flooring system Resistance of the circuit Footwear and flooring system Resistance of the circuit","categories":["other"],"row_index":177,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Footwear and flooring system Resistance of the circuit"},{"_id":"6a5a55ef9af9f73f38250b4e","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"involving a human being","test_object_en":"involving a human being","methodology":"Resistance value","methodology_en":"Resistance value","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Resistance value","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"involving a human being Resistance value involving a human being Resistance value","categories":["other"],"row_index":178,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"involving a human being Resistance value"},{"_id":"6a5a55ef9af9f73f38250b4f","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"involving a human being","test_object_en":"involving a human being","methodology":"from 1x103 Ω to 1x1012 Ω","methodology_en":"from 1x103 Ω to 1x1012 Ω","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"from 1x103 Ω to 1x1012 Ω","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"involving a human being from 1x103 Ω to 1x1012 Ω involving a human being from 1x103 Ω to 1x1012 Ω","categories":["other"],"row_index":179,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"involving a human being from 1x103 Ω to 1x1012 Ω"},{"_id":"6a5a55ef9af9f73f38250b50","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Wykładziny podłogowe i gotowe podłogi Floor coverings and ready-made floors","test_object_en":"Floor coverings and ready-made floors","methodology":"Rezystancja między punktami Rezystancja pionowa (tylko badania laboratoryjne) Rezystancja względem ziemi Wartość rezystancji od 1x103 Ω do 1x1012 Ω Point-to-point resistance Vertical resistance (laboratory tests only) Resistance to earth Resistance value from 1x103 Ω to 1x1012 Ω","methodology_en":"Point-to-point resistance Vertical resistance (laboratory tests only) Resistance to earth Resistance value from 1x103 Ω to 1x1012 Ω","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja między punktami Rezystancja pionowa (tylko badania laboratoryjne) Rezystancja względem ziemi Wartość rezystancji od 1x103 Ω do 1x1012 Ω Point-to-point resistance Vertical resistance (laboratory tests only) Resistance to earth Resistance value from 1x103 Ω to 1x1012 Ω","reference":"PN-EN 61340-4-1:2006","norm_bases":["PN-EN 61340-4-1:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wykładziny podłogowe i gotowe podłogi Floor coverings and ready-made floors Rezystancja między punktami Rezystancja pionowa (tylko badania laboratoryjne) Rezystancja względem ziemi Wartość rezystancji od 1x103 Ω do 1x1012 Ω Point-to-point resistance Vertical resistance (laboratory tests only) Resistance to earth Resistance value from 1x103 Ω to 1x1012 Ω PN-EN 61340-4-1:2006 Wykladziny podlogowe i gotowe podlogi Floor coverings and ready-made floors Rezystancja miedzy punktami Rezystancja pionowa (tylko badania laboratoryjne) Rezystancja wzgledem ziemi Wartosc rezystancji od 1x103 Ω do 1x1012 Ω Point-to-point resistance Vertical resistance (laboratory tests only) Resistance to earth Resistance value from 1x103 Ω to 1x1012 Ω PN-EN 61340-4-1:2006","categories":["other"],"row_index":180,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Floor coverings and ready-made floors Point-to-point resistance Vertical resistance (laboratory tests only) Resistance to earth Resistance value from 1x103 Ω to 1x1012 Ω PN-EN 61340-4-1:2006"},{"_id":"6a5a55ef9af9f73f38250b51","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Węże i przewody z gumy i tworzyw sztucznych Hoses and cables of rubber and plastics","test_object_en":"Hoses and cables of rubber and plastics","methodology":"Rezystancja elektryczna Wartość rezystancji od 1x103 do 1x1012 Ω Electric resistance Resistance value from 1x103 Ω to 1x1012 Ω","methodology_en":"Electrical resistance Resistance value from 1x103 to 1x1012 Ω Electric resistance Resistance value from 1x103 Ω to 1x1012 Ω","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja elektryczna Wartość rezystancji od 1x103 do 1x1012 Ω Electric resistance Resistance value from 1x103 Ω to 1x1012 Ω","reference":"PN-EN ISO 8031:2021-01","norm_bases":["PN-EN ISO 8031:2021-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Węże i przewody z gumy i tworzyw sztucznych Hoses and cables of rubber and plastics Rezystancja elektryczna Wartość rezystancji od 1x103 do 1x1012 Ω Electric resistance Resistance value from 1x103 Ω to 1x1012 Ω PN-EN ISO 8031:2021-01 Weze i przewody z gumy i tworzyw sztucznych Hoses and cables of rubber and plastics Rezystancja elektryczna Wartosc rezystancji od 1x103 do 1x1012 Ω Electric resistance Resistance value from 1x103 Ω to 1x1012 Ω PN-EN ISO 8031:2021-01","categories":["materials"],"row_index":181,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Hoses and cables of rubber and plastics Electrical resistance Resistance value from 1x103 to 1x1012 Ω Electric resistance Resistance value from 1x103 Ω to 1x1012 Ω PN-EN ISO 8031:2021-01"},{"_id":"6a5a55ef9af9f73f38250b52","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odzież ochronna, rękawice, obuwie Protective clothing, gloves, footwear","test_object_en":"Protective clothing, gloves, footwear","methodology":"Rezystancja powierzchniowa Wartość rezystancji od 1x103 do 1x1012 Ω Rezystywność powierzchniowa z obliczeń Surface resistance Resistance value from 1x103 Ω to 1x1012 Ω Surface resistivity from calculation","methodology_en":"Surface resistance Resistance value from 1x103 Ω to 1x1012 Ω Surface resistivity from calculation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja powierzchniowa Wartość rezystancji od 1x103 do 1x1012 Ω Rezystywność powierzchniowa z obliczeń Surface resistance Resistance value from 1x103 Ω to 1x1012 Ω Surface resistivity from calculation","reference":"PN-EN 1149-1:2008","norm_bases":["PN-EN 1149-1:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odzież ochronna, rękawice, obuwie Protective clothing, gloves, footwear Rezystancja powierzchniowa Wartość rezystancji od 1x103 do 1x1012 Ω Rezystywność powierzchniowa z obliczeń Surface resistance Resistance value from 1x103 Ω to 1x1012 Ω Surface resistivity from calculation PN-EN 1149-1:2008 Odziez ochronna, rekawice, obuwie Protective clothing, gloves, footwear Rezystancja powierzchniowa Wartosc rezystancji od 1x103 do 1x1012 Ω Rezystywnosc powierzchniowa z obliczen Surface resistance Resistance value from 1x103 Ω to 1x1012 Ω Surface resistivity from calculation PN-EN 1149-1:2008","categories":["other"],"row_index":182,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Protective clothing, gloves, footwear Surface resistance Resistance value from 1x103 Ω to 1x1012 Ω Surface resistivity from calculation PN-EN 1149-1:2008","search_zh":"防护服、手套、鞋 Protective clothing, gloves, footwear PN-EN 1149-1:2008","test_object_zh":"防护服、手套、鞋 Protective clothing, gloves, footwear"},{"_id":"6a5a55ef9af9f73f38250b53","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odzież ochronna, rękawice, obuwie Protective clothing, gloves, footwear","test_object_en":"Protective clothing, gloves, footwear","methodology":"Rezystancja skrośna Wartość rezystancji od 1x103 do 1x1012 Ω Cross resistance Resistance value from 1x103 Ω to 1x1012 Ω","methodology_en":"Cross resistance Resistance value from 1x103 Ω to 1x1012 Ω","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja skrośna Wartość rezystancji od 1x103 do 1x1012 Ω Cross resistance Resistance value from 1x103 Ω to 1x1012 Ω","reference":"PN-EN 1149-2:1999 PN-EN 16350:2014-08","norm_bases":["PN-EN 1149-2:1999 PN-EN 16350:2014-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odzież ochronna, rękawice, obuwie Protective clothing, gloves, footwear Rezystancja skrośna Wartość rezystancji od 1x103 do 1x1012 Ω Cross resistance Resistance value from 1x103 Ω to 1x1012 Ω PN-EN 1149-2:1999 PN-EN 16350:2014-08 Odziez ochronna, rekawice, obuwie Protective clothing, gloves, footwear Rezystancja skrosna Wartosc rezystancji od 1x103 do 1x1012 Ω Cross resistance Resistance value from 1x103 Ω to 1x1012 Ω PN-EN 1149-2:1999 PN-EN 16350:2014-08","categories":["other"],"row_index":183,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Protective clothing, gloves, footwear Cross resistance Resistance value from 1x103 Ω to 1x1012 Ω PN-EN 1149-2:1999 PN-EN 16350:2014-08","search_zh":"防护服、手套、鞋 Protective clothing, gloves, footwear PN-EN 1149-2:1999 PN-EN 16350:2014-08","test_object_zh":"防护服、手套、鞋 Protective clothing, gloves, footwear"},{"_id":"6a5a55ef9af9f73f38250b54","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odzież ochronna, rękawice, obuwie Protective clothing, gloves, footwear","test_object_en":"Protective clothing, gloves, footwear","methodology":"Rezystancja elektryczna Wartość rezystancji od 1x103 do 1x1012 Ω Electric resistance Resistance value from 1x103 Ω to 1x1012 Ω","methodology_en":"Electrical resistance Resistance value from 1x103 to 1x1012 Ω Electric resistance Resistance value from 1x103 Ω to 1x1012 Ω","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja elektryczna Wartość rezystancji od 1x103 do 1x1012 Ω Electric resistance Resistance value from 1x103 Ω to 1x1012 Ω","reference":"PN-EN IEC 61340-4-3:2018-04","norm_bases":["PN-EN IEC 61340-4-3:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odzież ochronna, rękawice, obuwie Protective clothing, gloves, footwear Rezystancja elektryczna Wartość rezystancji od 1x103 do 1x1012 Ω Electric resistance Resistance value from 1x103 Ω to 1x1012 Ω PN-EN IEC 61340-4-3:2018-04 Odziez ochronna, rekawice, obuwie Protective clothing, gloves, footwear Rezystancja elektryczna Wartosc rezystancji od 1x103 do 1x1012 Ω Electric resistance Resistance value from 1x103 Ω to 1x1012 Ω PN-EN IEC 61340-4-3:2018-04","categories":["other"],"row_index":184,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Protective clothing, gloves, footwear Electrical resistance Resistance value from 1x103 to 1x1012 Ω Electric resistance Resistance value from 1x103 Ω to 1x1012 Ω PN-EN IEC 61340-4-3:2018-04","search_zh":"防护服、手套、鞋 Protective clothing, gloves, footwear PN-EN IEC 61340-4-3:2018-04","test_object_zh":"防护服、手套、鞋 Protective clothing, gloves, footwear"},{"_id":"6a5a55ef9af9f73f38250b55","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odzież ochronna, rękawice, obuwie Protective clothing, gloves, footwear","test_object_en":"Protective clothing, gloves, footwear","methodology":"Rezystancja między punktami Wartość rezystancji od 1x103 do 1x1012 Ω Point-to-point resistance Resistance value from 1x103 Ω to 1x1012 Ω","methodology_en":"Point-to-point resistance Resistance value from 1x103 Ω to 1x1012 Ω","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja między punktami Wartość rezystancji od 1x103 do 1x1012 Ω Point-to-point resistance Resistance value from 1x103 Ω to 1x1012 Ω","reference":"PN-EN 61340-4-9:2016-11","norm_bases":["PN-EN 61340-4-9:2016-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odzież ochronna, rękawice, obuwie Protective clothing, gloves, footwear Rezystancja między punktami Wartość rezystancji od 1x103 do 1x1012 Ω Point-to-point resistance Resistance value from 1x103 Ω to 1x1012 Ω PN-EN 61340-4-9:2016-11 Odziez ochronna, rekawice, obuwie Protective clothing, gloves, footwear Rezystancja miedzy punktami Wartosc rezystancji od 1x103 do 1x1012 Ω Point-to-point resistance Resistance value from 1x103 Ω to 1x1012 Ω PN-EN 61340-4-9:2016-11","categories":["other"],"row_index":185,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Protective clothing, gloves, footwear Point-to-point resistance Resistance value from 1x103 Ω to 1x1012 Ω PN-EN 61340-4-9:2016-11","search_zh":"防护服、手套、鞋 Protective clothing, gloves, footwear PN-EN 61340-4-9:2016-11","test_object_zh":"防护服、手套、鞋 Protective clothing, gloves, footwear"},{"_id":"6a5a55ef9af9f73f38250b56","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Materiały, wyroby i urządzenia metalowe Metal materials, products and equipment","test_object_en":"Metal materials, products and equipment","methodology":"Rezystancja elektryczna Wartość rezystancji od 1x10-6 do 1x101 Ω Electric resistance Resistance value from 1x10-6 Ω to 1x101 Ω","methodology_en":"Electric resistance Resistance value from 1x10-6 Ω to 1x101 Ω","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja elektryczna Wartość rezystancji od 1x10-6 do 1x101 Ω Electric resistance Resistance value from 1x10-6 Ω to 1x101 Ω","reference":"PN-EN 50540:2010","norm_bases":["PN-EN 50540:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały, wyroby i urządzenia metalowe Metal materials, products and equipment Rezystancja elektryczna Wartość rezystancji od 1x10-6 do 1x101 Ω Electric resistance Resistance value from 1x10-6 Ω to 1x101 Ω PN-EN 50540:2010 Materialy, wyroby i urzadzenia metalowe Metal materials, products and equipment Rezystancja elektryczna Wartosc rezystancji od 1x10-6 do 1x101 Ω Electric resistance Resistance value from 1x10-6 Ω to 1x101 Ω PN-EN 50540:2010","categories":["materials"],"row_index":186,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Metal materials, products and equipment Electric resistance Resistance value from 1x10-6 Ω to 1x101 Ω PN-EN 50540:2010"},{"_id":"6a5a55ef9af9f73f38250b57","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Środowisko pracy - powietrze Working environment - air","test_object_en":"Working environment - air","methodology":"Pobieranie próbek w celu oceny narażenia zawodowego na - pyły przemysłowe - frakcja wdychalna - frakcja respirabilna Metoda dozymetrii indywidualnej Air sampling for workplace exposure assessment to - industrial dust - inhalable fraction - respirable fraction Personal sampling method","methodology_en":"Air sampling for workplace exposure assessment to - industrial dust - inhalable fraction - respirable fraction Personal sampling method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek w celu oceny narażenia zawodowego na - pyły przemysłowe - frakcja wdychalna - frakcja respirabilna Metoda dozymetrii indywidualnej Air sampling for workplace exposure assessment to - industrial dust - inhalable fraction - respirable fraction Personal sampling method","reference":"PN-Z-04008-7:2002 PN-Z-04008-7/Az1:2004 PN-G-04035:2002+Az1:2005","norm_bases":["PN-Z-04008-7:2002 PN-Z-04008-7/Az1:2004 PN-G-04035:2002+Az1:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Working environment - air Pobieranie próbek w celu oceny narażenia zawodowego na - pyły przemysłowe - frakcja wdychalna - frakcja respirabilna Metoda dozymetrii indywidualnej Air sampling for workplace exposure assessment to - industrial dust - inhalable fraction - respirable fraction Personal sampling method PN-Z-04008-7:2002 PN-Z-04008-7/Az1:2004 PN-G-04035:2002+Az1:2005 Srodowisko pracy - powietrze Working environment - air Pobieranie probek w celu oceny narazenia zawodowego na - pyly przemyslowe - frakcja wdychalna - frakcja respirabilna Metoda dozymetrii indywidualnej Air sampling for workplace exposure assessment to - industrial dust - inhalable fraction - respirable fraction Personal sampling method PN-Z-04008-7:2002 PN-Z-04008-7/Az1:2004 PN-G-04035:2002+Az1:2005","categories":["environment"],"row_index":187,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Working environment - air Air sampling for workplace exposure assessment to - industrial dust - inhalable fraction - respirable fraction Personal sampling method PN-Z-04008-7:2002 PN-Z-04008-7/Az1:2004 PN-G-04035:2002+Az1:2005","search_zh":"工作环境 － 空气 Working environment - air PN-Z-04008-7:2002 PN-Z-04008-7/Az1:2004 PN-G-04035:2002+Az1:2005","test_object_zh":"工作环境 － 空气 Working environment - air"},{"_id":"6a5a55ef9af9f73f38250b58","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Środowisko pracy - powietrze Working environment - air","test_object_en":"Working environment - air","methodology":"Wskaźnik narażenia (z obliczeń) Occupational exposure factor (calculated)","methodology_en":"Occupational exposure factor (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik narażenia (z obliczeń) Occupational exposure factor (calculated)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Working environment - air Wskaźnik narażenia (z obliczeń) Occupational exposure factor (calculated) Srodowisko pracy - powietrze Working environment - air Wskaznik narazenia (z obliczen) Occupational exposure factor (calculated)","categories":["environment"],"row_index":188,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Working environment - air Occupational exposure factor (calculated)","search_zh":"工作环境 － 空气 Working environment - air","test_object_zh":"工作环境 － 空气 Working environment - air"},{"_id":"6a5a55ef9af9f73f38250b59","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Środowisko pracy - powietrze Working environment - air","test_object_en":"Working environment - air","methodology":"Stężenie pyłu - frakcja wdychalna Stężenie pyłu - frakcja respirabilna Zakres: (0,1 – 300) mg/m3 Metoda grawimetryczna Dust concentration - inhalable fraction Dust concentration - respirable fraction Range: (0,1 – 300) mg/m3 Gravimetric method","methodology_en":"Dust concentration - inhalable fraction Dust concentration - respirable fraction Range: (0,1 – 300) mg/m3 Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pyłu - frakcja wdychalna Stężenie pyłu - frakcja respirabilna Zakres: (0,1 – 300) mg/m3 Metoda grawimetryczna Dust concentration - inhalable fraction Dust concentration - respirable fraction Range: (0,1 – 300) mg/m3 Gravimetric method","reference":"Procedura KD-2.2/ZLGIG/PB-2207 edycja 4 z 25.08.2023 r. Procedura KD-2.2/ZLGIG/PB-2208 edycja 4 z 25.08.2023 r. Procedura KD-2.2/ZLGIG/PB-2209 edycja 3 z 25.08.2023 r. Procedura KD-2.2/ZLGIG/PB-2210 edycja 6 z 25.08.2023 r. Procedure KD-2.2/ZLGIG/PB-2207 4th edition of 25 August 2023 Procedure KD-2.2/ZLGIG/PB-2208 4th edition of 25 August 2023 Procedure KD-2.2/ZLGIG/PB-2209 3rd edition of 25 August 2023 Procedure KD-2.2/ZLGIG/PB-2210 6th edition of 25 August 2023","norm_bases":["Procedura KD-2.2/ZLGIG/PB-2207 edycja 4 z 25.08.2023 r. Procedura KD-2.2/ZLGIG/PB-2208 edycja 4 z 25.08.2023 r. Procedura KD-2.2/ZLGIG/PB-2209 edycja 3 z 25.08.2023 r. Procedura KD-2.2/ZLGIG/PB-2210 edycja 6 z 25.08.2023 r. Procedure KD-2.2/ZLGIG/PB-2207 4th edition of 25 August 2023 Procedure KD-2.2/ZLGIG/PB-2208 4th edition of 25 August 2023 Procedure KD-2.2/ZLGIG/PB-2209 3rd edition of 25 August 2023 Procedure KD-2.2/ZLGIG/PB-2210 6th edition of 25 August 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Working environment - air Stężenie pyłu - frakcja wdychalna Stężenie pyłu - frakcja respirabilna Zakres: (0,1 – 300) mg/m3 Metoda grawimetryczna Dust concentration - inhalable fraction Dust concentration - respirable fraction Range: (0,1 – 300) mg/m3 Gravimetric method Procedura KD-2.2/ZLGIG/PB-2207 edycja 4 z 25.08.2023 r. Procedura KD-2.2/ZLGIG/PB-2208 edycja 4 z 25.08.2023 r. Procedura KD-2.2/ZLGIG/PB-2209 edycja 3 z 25.08.2023 r. Procedura KD-2.2/ZLGIG/PB-2210 edycja 6 z 25.08.2023 r. Procedure KD-2.2/ZLGIG/PB-2207 4th edition of 25 August 2023 Procedure KD-2.2/ZLGIG/PB-2208 4th edition of 25 August 2023 Procedure KD-2.2/ZLGIG/PB-2209 3rd edition of 25 August 2023 Procedure KD-2.2/ZLGIG/PB-2210 6th edition of 25 August 2023 Srodowisko pracy - powietrze Working environment - air Stezenie pylu - frakcja wdychalna Stezenie pylu - frakcja respirabilna Zakres: (0,1 – 300) mg/m3 Metoda grawimetryczna Dust concentration - inhalable fraction Dust concentration - respirable fraction Range: (0,1 – 300) mg/m3 Gravimetric method Procedura KD-2.2/ZLGIG/PB-2207 edycja 4 z 25.08.2023 r. Procedura KD-2.2/ZLGIG/PB-2208 edycja 4 z 25.08.2023 r. Procedura KD-2.2/ZLGIG/PB-2209 edycja 3 z 25.08.2023 r. Procedura KD-2.2/ZLGIG/PB-2210 edycja 6 z 25.08.2023 r. Procedure KD-2.2/ZLGIG/PB-2207 4th edition of 25 August 2023 Procedure KD-2.2/ZLGIG/PB-2208 4th edition of 25 August 2023 Procedure KD-2.2/ZLGIG/PB-2209 3rd edition of 25 August 2023 Procedure KD-2.2/ZLGIG/PB-2210 6th edition of 25 August 2023","categories":["environment"],"row_index":189,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Working environment - air Dust concentration - inhalable fraction Dust concentration - respirable fraction Range: (0,1 – 300) mg/m3 Gravimetric method Procedura KD-2.2/ZLGIG/PB-2207 edycja 4 z 25.08.2023 r. Procedura KD-2.2/ZLGIG/PB-2208 edycja 4 z 25.08.2023 r. Procedura KD-2.2/ZLGIG/PB-2209 edycja 3 z 25.08.2023 r. Procedura KD-2.2/ZLGIG/PB-2210 edycja 6 z 25.08.2023 r. Procedure KD-2.2/ZLGIG/PB-2207 4th edition of 25 August 2023 Procedure KD-2.2/ZLGIG/PB-2208 4th edition of 25 August 2023 Procedure KD-2.2/ZLGIG/PB-2209 3rd edition of 25 August 2023 Procedure KD-2.2/ZLGIG/PB-2210 6th edition of 25 August 2023","search_zh":"工作环境 － 空气 Working environment - air Procedura KD-2.2/ZLGIG/PB-2207 edycja 4 z 25.08.2023 r. Procedura KD-2.2/ZLGIG/PB-2208 edycja 4 z 25.08.2023 r. Procedura KD-2.2/ZLGIG/PB-2209 edycja 3 z 25.08.2023 r. Procedura KD-2.2/ZLGIG/PB-2210 edycja 6 z 25.08.2023 r. Procedure KD-2.2/ZLGIG/PB-2207 4th edition of 25 August 2023 Procedure KD-2.2/ZLGIG/PB-2208 4th edition of 25 August 2023 Procedure KD-2.2/ZLGIG/PB-2209 3rd edition of 25 August 2023 Procedure KD-2.2/ZLGIG/PB-2210 6th edition of 25 August 2023","test_object_zh":"工作环境 － 空气 Working environment - air"},{"_id":"6a5a55ef9af9f73f38250b5a","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtr membranowy Working environment - air samples collected on membrane filter","test_object_en":"Working environment - air samples collected on membrane filter","methodology":"Zawartość respirabilnych sztucznych włókien mineralnych oraz włókien ceramicznych Zakres: (0,5 – 200) włókien/100 pól Metoda mikroskopii optycznej Contents of respirable synthetic mineral fibres and ceramic fibres Range: (0,5 – 200) fibres per 100 of graticule ereas examined Phase Contrast Microscopy (PCM)","methodology_en":"Contents of respirable synthetic mineral fibres and ceramic fibres Range: (0,5 – 200) fibres per 100 of graticule ereas examined Phase Contrast Microscopy (PCM)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość respirabilnych sztucznych włókien mineralnych oraz włókien ceramicznych Zakres: (0,5 – 200) włókien/100 pól Metoda mikroskopii optycznej Contents of respirable synthetic mineral fibres and ceramic fibres Range: (0,5 – 200) fibres per 100 of graticule ereas examined Phase Contrast Microscopy (PCM)","reference":"Procedura KD-2.2/ZLGIG/PB-2205-1 edycja 4 z 25.08.2023 r. Procedure KD-2.2/ZLGIG/PB-2205-1 4th edition of 25 August 2023","norm_bases":["Procedura KD-2.2/ZLGIG/PB-2205-1 edycja 4 z 25.08.2023 r. Procedure KD-2.2/ZLGIG/PB-2205-1 4th edition of 25 August 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtr membranowy Working environment - air samples collected on membrane filter Zawartość respirabilnych sztucznych włókien mineralnych oraz włókien ceramicznych Zakres: (0,5 – 200) włókien/100 pól Metoda mikroskopii optycznej Contents of respirable synthetic mineral fibres and ceramic fibres Range: (0,5 – 200) fibres per 100 of graticule ereas examined Phase Contrast Microscopy (PCM) Procedura KD-2.2/ZLGIG/PB-2205-1 edycja 4 z 25.08.2023 r. Procedure KD-2.2/ZLGIG/PB-2205-1 4th edition of 25 August 2023 Srodowisko pracy - probki powietrza pobrane na filtr membranowy Working environment - air samples collected on membrane filter Zawartosc respirabilnych sztucznych wlokien mineralnych oraz wlokien ceramicznych Zakres: (0,5 – 200) wlokien/100 pol Metoda mikroskopii optycznej Contents of respirable synthetic mineral fibres and ceramic fibres Range: (0,5 – 200) fibres per 100 of graticule ereas examined Phase Contrast Microscopy (PCM) Procedura KD-2.2/ZLGIG/PB-2205-1 edycja 4 z 25.08.2023 r. Procedure KD-2.2/ZLGIG/PB-2205-1 4th edition of 25 August 2023","categories":["environment","materials"],"row_index":190,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Working environment - air samples collected on membrane filter Contents of respirable synthetic mineral fibres and ceramic fibres Range: (0,5 – 200) fibres per 100 of graticule ereas examined Phase Contrast Microscopy (PCM) Procedura KD-2.2/ZLGIG/PB-2205-1 edycja 4 z 25.08.2023 r. Procedure KD-2.2/ZLGIG/PB-2205-1 4th edition of 25 August 2023"},{"_id":"6a5a55ef9af9f73f38250b5b","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtr membranowy Working environment - air samples collected on membrane filter","test_object_en":"Working environment - air samples collected on membrane filter","methodology":"Zawartość respirabilnych włókien azbestu Zakres: (0,5 – 200) włókien/100 pól Metoda mikroskopii optycznej Contents of respirable asbestos fibres Range: (0,5 – 200) fibres per 100 of graticule ereas examined Phase Contrast Microscopy (PCM) Polarized Light Microscopy (PLM)","methodology_en":"Contents of respirable asbestos fibres Range: (0,5 – 200) fibres per 100 of graticule ereas examined Phase Contrast Microscopy (PCM) Polarized Light Microscopy (PLM)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość respirabilnych włókien azbestu Zakres: (0,5 – 200) włókien/100 pól Metoda mikroskopii optycznej Contents of respirable asbestos fibres Range: (0,5 – 200) fibres per 100 of graticule ereas examined Phase Contrast Microscopy (PCM) Polarized Light Microscopy (PLM)","reference":"Procedura KD-2.2/ZLGIG/PB-2205-2 edycja 3 z 25.08.2023 r. Procedure KD-2.2/ZLGIG/PB-2205-2 3rd edition of 25 August 2023","norm_bases":["Procedura KD-2.2/ZLGIG/PB-2205-2 edycja 3 z 25.08.2023 r. Procedure KD-2.2/ZLGIG/PB-2205-2 3rd edition of 25 August 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtr membranowy Working environment - air samples collected on membrane filter Zawartość respirabilnych włókien azbestu Zakres: (0,5 – 200) włókien/100 pól Metoda mikroskopii optycznej Contents of respirable asbestos fibres Range: (0,5 – 200) fibres per 100 of graticule ereas examined Phase Contrast Microscopy (PCM) Polarized Light Microscopy (PLM) Procedura KD-2.2/ZLGIG/PB-2205-2 edycja 3 z 25.08.2023 r. Procedure KD-2.2/ZLGIG/PB-2205-2 3rd edition of 25 August 2023 Srodowisko pracy - probki powietrza pobrane na filtr membranowy Working environment - air samples collected on membrane filter Zawartosc respirabilnych wlokien azbestu Zakres: (0,5 – 200) wlokien/100 pol Metoda mikroskopii optycznej Contents of respirable asbestos fibres Range: (0,5 – 200) fibres per 100 of graticule ereas examined Phase Contrast Microscopy (PCM) Polarized Light Microscopy (PLM) Procedura KD-2.2/ZLGIG/PB-2205-2 edycja 3 z 25.08.2023 r. Procedure KD-2.2/ZLGIG/PB-2205-2 3rd edition of 25 August 2023","categories":["environment","materials"],"row_index":191,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Working environment - air samples collected on membrane filter Contents of respirable asbestos fibres Range: (0,5 – 200) fibres per 100 of graticule ereas examined Phase Contrast Microscopy (PCM) Polarized Light Microscopy (PLM) Procedura KD-2.2/ZLGIG/PB-2205-2 edycja 3 z 25.08.2023 r. Procedure KD-2.2/ZLGIG/PB-2205-2 3rd edition of 25 August 2023"},{"_id":"6a5a55ef9af9f73f38250b5c","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość popiołu Zakres: (1,00 – 58,00)% Metoda wagowa Ash content Range: (1,00 – 58,00)% Weight method","methodology_en":"Ash content Range: (1,00 – 58,00)% Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość popiołu Zakres: (1,00 – 58,00)% Metoda wagowa Ash content Range: (1,00 – 58,00)% Weight method","reference":"PN-ISO 1171:2002","norm_bases":["PN-ISO 1171:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Zawartość popiołu Zakres: (1,00 – 58,00)% Metoda wagowa Ash content Range: (1,00 – 58,00)% Weight method PN-ISO 1171:2002 Paliwa stale: wegiel kamienny Solid fuels: hard coal Zawartosc popiolu Zakres: (1,00 – 58,00)% Metoda wagowa Ash content Range: (1,00 – 58,00)% Weight method PN-ISO 1171:2002","categories":["petro"],"row_index":192,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Ash content Range: (1,00 – 58,00)% Weight method PN-ISO 1171:2002","search_zh":"固体燃料：烟煤 PN-ISO 1171:2002","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ef9af9f73f38250b5d","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci przemijającej Zakres: (0,00 – 15,00)% Metoda wagowa Transient moisture content Range: (0,00 – 15,00)% Weight method","methodology_en":"Transient moisture content Range: (0,00 – 15,00)% Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci przemijającej Zakres: (0,00 – 15,00)% Metoda wagowa Transient moisture content Range: (0,00 – 15,00)% Weight method","reference":"PN-G-04511:1980","norm_bases":["PN-G-04511:1980"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Zawartość wilgoci przemijającej Zakres: (0,00 – 15,00)% Metoda wagowa Transient moisture content Range: (0,00 – 15,00)% Weight method PN-G-04511:1980 Paliwa stale: wegiel kamienny Solid fuels: hard coal Zawartosc wilgoci przemijajacej Zakres: (0,00 – 15,00)% Metoda wagowa Transient moisture content Range: (0,00 – 15,00)% Weight method PN-G-04511:1980","categories":["petro"],"row_index":193,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Transient moisture content Range: (0,00 – 15,00)% Weight method PN-G-04511:1980","search_zh":"固体燃料：烟煤 PN-G-04511:1980","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ef9af9f73f38250b5e","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci w stanie powietrznosuchym (wilgoć higroskopijna) Zakres: (0,10 – 20,00)% Metoda wagowa Moisture content in air-dry state (hygroscopic moisture) Range: (0,10 – 20,00)% Weight method","methodology_en":"Moisture content in air-dry state (hygroscopic moisture) Range: (0,10 – 20,00)% Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci w stanie powietrznosuchym (wilgoć higroskopijna) Zakres: (0,10 – 20,00)% Metoda wagowa Moisture content in air-dry state (hygroscopic moisture) Range: (0,10 – 20,00)% Weight method","reference":"PN-G-04511:1980 punkt 2.2.1","norm_bases":["PN-G-04511:1980 punkt 2.2.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Zawartość wilgoci w stanie powietrznosuchym (wilgoć higroskopijna) Zakres: (0,10 – 20,00)% Metoda wagowa Moisture content in air-dry state (hygroscopic moisture) Range: (0,10 – 20,00)% Weight method PN-G-04511:1980 punkt 2.2.1 Paliwa stale: wegiel kamienny Solid fuels: hard coal Zawartosc wilgoci w stanie powietrznosuchym (wilgoc higroskopijna) Zakres: (0,10 – 20,00)% Metoda wagowa Moisture content in air-dry state (hygroscopic moisture) Range: (0,10 – 20,00)% Weight method PN-G-04511:1980 punkt 2.2.1","categories":["petro"],"row_index":194,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Moisture content in air-dry state (hygroscopic moisture) Range: (0,10 – 20,00)% Weight method PN-G-04511:1980 punkt 2.2.1","search_zh":"固体燃料：烟煤 PN-G-04511:1980 punkt 2.2.1","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ef9af9f73f38250b5f","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Przewód z włóknem optycznym Optical ground wire","test_object_en":"Optical ground wire","methodology":"Sprawdzenie zachowania się ośrodka optycznego podczas rozciągania przewodu Metoda obciążania siłą Zakres: siła (0 – 5000) kN Tensile performance test Force method Range: force (0 – 5000) kN","methodology_en":"Tensile performance test of the optical medium during conductor stretching Force method Range: force (0 – 5000) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sprawdzenie zachowania się ośrodka optycznego podczas rozciągania przewodu Metoda obciążania siłą Zakres: siła (0 – 5000) kN Tensile performance test Force method Range: force (0 – 5000) kN","reference":"PN-EN 60794-1-21:2015-07 p. 3 metoda E1/method E1","norm_bases":["PN-EN 60794-1-21:2015-07 p. 3 metoda E1/method E1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewód z włóknem optycznym Optical ground wire Sprawdzenie zachowania się ośrodka optycznego podczas rozciągania przewodu Metoda obciążania siłą Zakres: siła (0 – 5000) kN Tensile performance test Force method Range: force (0 – 5000) kN PN-EN 60794-1-21:2015-07 p. 3 metoda E1/method E1 Przewod z wloknem optycznym Optical ground wire Sprawdzenie zachowania sie osrodka optycznego podczas rozciagania przewodu Metoda obciazania sila Zakres: sila (0 – 5000) kN Tensile performance test Force method Range: force (0 – 5000) kN PN-EN 60794-1-21:2015-07 p. 3 metoda E1/method E1","categories":["other"],"row_index":195,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Optical ground wire Tensile performance test of the optical medium during conductor stretching Force method Range: force (0 – 5000) kN PN-EN 60794-1-21:2015-07 p. 3 metoda E1/method E1","search_zh":"光纤复合架空地线 Optical ground wire PN-EN 60794-1-21:2015-07 p. 3 metoda E1/method E1","test_object_zh":"光纤复合架空地线 Optical ground wire"},{"_id":"6a5a55ef9af9f73f38250b60","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Przewód z włóknem optycznym Optical ground wire","test_object_en":"Optical ground wire","methodology":"Sprawdzenie zachowania się przewodu w warunkach obciążenia siłą rozciągającą Metoda obciążania siłą Zakres: siła (0 – 5000) kN wydłużenie (0 – 2000) mm Stress-strain test Force method Range: force (0 – 5000) kN elongation (0 – 2000) mm","methodology_en":"Stress-strain test of the conductor under tensile load Force method Range: force (0 – 5000) kN elongation (0 – 2000) mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sprawdzenie zachowania się przewodu w warunkach obciążenia siłą rozciągającą Metoda obciążania siłą Zakres: siła (0 – 5000) kN wydłużenie (0 – 2000) mm Stress-strain test Force method Range: force (0 – 5000) kN elongation (0 – 2000) mm","reference":"PN-EN 50182:2002 p. 6.4.7 i/and Aneks C/Annex C PN-IEC 1089:1994/A1:2000 – Aneks B/Annex B","norm_bases":["PN-EN 50182:2002 p. 6.4.7 i/and Aneks C/Annex C PN-IEC 1089:1994/A1:2000 – Aneks B/Annex B"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewód z włóknem optycznym Optical ground wire Sprawdzenie zachowania się przewodu w warunkach obciążenia siłą rozciągającą Metoda obciążania siłą Zakres: siła (0 – 5000) kN wydłużenie (0 – 2000) mm Stress-strain test Force method Range: force (0 – 5000) kN elongation (0 – 2000) mm PN-EN 50182:2002 p. 6.4.7 i/and Aneks C/Annex C PN-IEC 1089:1994/A1:2000 – Aneks B/Annex B Przewod z wloknem optycznym Optical ground wire Sprawdzenie zachowania sie przewodu w warunkach obciazenia sila rozciagajaca Metoda obciazania sila Zakres: sila (0 – 5000) kN wydluzenie (0 – 2000) mm Stress-strain test Force method Range: force (0 – 5000) kN elongation (0 – 2000) mm PN-EN 50182:2002 p. 6.4.7 i/and Aneks C/Annex C PN-IEC 1089:1994/A1:2000 – Aneks B/Annex B","categories":["other"],"row_index":196,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Optical ground wire Stress-strain test of the conductor under tensile load Force method Range: force (0 – 5000) kN elongation (0 – 2000) mm PN-EN 50182:2002 p. 6.4.7 i/and Aneks C/Annex C PN-IEC 1089:1994/A1:2000 – Aneks B/Annex B","search_zh":"光纤复合架空地线 Optical ground wire PN-EN 50182:2002 p. 6.4.7 i/and Aneks C/Annex C PN-IEC 1089:1994/A1:2000 – Aneks B/Annex B","test_object_zh":"光纤复合架空地线 Optical ground wire"},{"_id":"6a5a55ef9af9f73f38250b61","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Przewód z włóknem optycznym Optical ground wire","test_object_en":"Optical ground wire","methodology":"Sprawdzenie siły zrywającej przewód Próba rozciągania Zakres: siła (0 – 5000) kN Breaking strength test Tensile test Range: force (0 – 5000) kN","methodology_en":"Breaking strength test Tensile test Range: force (0 – 5000) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sprawdzenie siły zrywającej przewód Próba rozciągania Zakres: siła (0 – 5000) kN Breaking strength test Tensile test Range: force (0 – 5000) kN","reference":"EN 60794-4-10:2015-03 p. 8.3.4 PN-EN 50182:2002 p. 6.4.8","norm_bases":["EN 60794-4-10:2015-03 p. 8.3.4 PN-EN 50182:2002 p. 6.4.8"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewód z włóknem optycznym Optical ground wire Sprawdzenie siły zrywającej przewód Próba rozciągania Zakres: siła (0 – 5000) kN Breaking strength test Tensile test Range: force (0 – 5000) kN EN 60794-4-10:2015-03 p. 8.3.4 PN-EN 50182:2002 p. 6.4.8 Przewod z wloknem optycznym Optical ground wire Sprawdzenie sily zrywajacej przewod Proba rozciagania Zakres: sila (0 – 5000) kN Breaking strength test Tensile test Range: force (0 – 5000) kN EN 60794-4-10:2015-03 p. 8.3.4 PN-EN 50182:2002 p. 6.4.8","categories":["other"],"row_index":197,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Optical ground wire Breaking strength test Tensile test Range: force (0 – 5000) kN EN 60794-4-10:2015-03 p. 8.3.4 PN-EN 50182:2002 p. 6.4.8","search_zh":"光纤复合架空地线 Optical ground wire EN 60794-4-10:2015-03 p. 8.3.4 PN-EN 50182:2002 p. 6.4.8","test_object_zh":"光纤复合架空地线 Optical ground wire"},{"_id":"6a5a55ef9af9f73f38250b62","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Przewód z włóknem optycznym Optical ground wire","test_object_en":"Optical ground wire","methodology":"Badanie wodoszczelności wzdłużnej Próba hydrostatyczna Water penetration test Hydrostatic test","methodology_en":"Water penetration test Hydrostatic test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Badanie wodoszczelności wzdłużnej Próba hydrostatyczna Water penetration test Hydrostatic test","reference":"PN-EN 60794-1-22:2018-04 p. 5 Metoda/method F5B","norm_bases":["PN-EN 60794-1-22:2018-04 p. 5 Metoda/method F5B"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewód z włóknem optycznym Optical ground wire Badanie wodoszczelności wzdłużnej Próba hydrostatyczna Water penetration test Hydrostatic test PN-EN 60794-1-22:2018-04 p. 5 Metoda/method F5B Przewod z wloknem optycznym Optical ground wire Badanie wodoszczelnosci wzdluznej Proba hydrostatyczna Water penetration test Hydrostatic test PN-EN 60794-1-22:2018-04 p. 5 Metoda/method F5B","categories":["water"],"row_index":198,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Optical ground wire Water penetration test Hydrostatic test PN-EN 60794-1-22:2018-04 p. 5 Metoda/method F5B","search_zh":"光纤复合架空地线 Optical ground wire PN-EN 60794-1-22:2018-04 p. 5 Metoda/method F5B","test_object_zh":"光纤复合架空地线 Optical ground wire"},{"_id":"6a5a55ef9af9f73f38250b63","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Przewody wielodrutowe Stranded conductors","test_object_en":"Stranded conductors","methodology":"Badanie pełzania przewodu Metoda obciążania siłą Zakres: siła pełzania (0 – 100) kN średnice przewodu (< 40 mm) Creep test Force method Range: creep force (0 – 100) kN conductor diameter (< 40 mm)","methodology_en":"Conductor creep test Force loading method Range: creep force (0 – 100) kN conductor diameter (< 40 mm) Creep test Force method Range: creep force (0 – 100) kN conductor diameter (< 40 mm)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Badanie pełzania przewodu Metoda obciążania siłą Zakres: siła pełzania (0 – 100) kN średnice przewodu (< 40 mm) Creep test Force method Range: creep force (0 – 100) kN conductor diameter (< 40 mm)","reference":"PN-EN 61395:2002","norm_bases":["PN-EN 61395:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody wielodrutowe Stranded conductors Badanie pełzania przewodu Metoda obciążania siłą Zakres: siła pełzania (0 – 100) kN średnice przewodu (< 40 mm) Creep test Force method Range: creep force (0 – 100) kN conductor diameter (< 40 mm) PN-EN 61395:2002 Przewody wielodrutowe Stranded conductors Badanie pelzania przewodu Metoda obciazania sila Zakres: sila pelzania (0 – 100) kN srednice przewodu (< 40 mm) Creep test Force method Range: creep force (0 – 100) kN conductor diameter (< 40 mm) PN-EN 61395:2002","categories":["other"],"row_index":199,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Stranded conductors Conductor creep test Force loading method Range: creep force (0 – 100) kN conductor diameter (< 40 mm) Creep test Force method Range: creep force (0 – 100) kN conductor diameter (< 40 mm) PN-EN 61395:2002","search_zh":"绞合导线 Stranded conductors PN-EN 61395:2002","test_object_zh":"绞合导线 Stranded conductors"},{"_id":"6a5a55ef9af9f73f38250b64","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Przewody wielodrutowe Stranded conductors","test_object_en":"Stranded conductors","methodology":"Temperatura kroplenia smaru Zakres: Temperatura (0 – 288) °C Drop point of grease Range: Temperature (0 – 288) °C","methodology_en":"Drop point of grease Range: Temperature (0 – 288) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Temperatura kroplenia smaru Zakres: Temperatura (0 – 288) °C Drop point of grease Range: Temperature (0 – 288) °C","reference":"PN-EN 50326:2003 PN-ISO 2176:2011","norm_bases":["PN-EN 50326:2003 PN-ISO 2176:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody wielodrutowe Stranded conductors Temperatura kroplenia smaru Zakres: Temperatura (0 – 288) °C Drop point of grease Range: Temperature (0 – 288) °C PN-EN 50326:2003 PN-ISO 2176:2011 Przewody wielodrutowe Stranded conductors Temperatura kroplenia smaru Zakres: Temperatura (0 – 288) °C Drop point of grease Range: Temperature (0 – 288) °C PN-EN 50326:2003 PN-ISO 2176:2011","categories":["petro"],"row_index":200,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Stranded conductors Drop point of grease Range: Temperature (0 – 288) °C PN-EN 50326:2003 PN-ISO 2176:2011","search_zh":"绞合导线 Stranded conductors PN-EN 50326:2003 PN-ISO 2176:2011","test_object_zh":"绞合导线 Stranded conductors"},{"_id":"6a5a55ef9af9f73f38250b65","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Przewody wielodrutowe Stranded conductors","test_object_en":"Stranded conductors","methodology":"Siła rozciągająca Zakres: (0 – 5000) kN Próba rozciągania Tensile force Range: (0 – 5000) kN Tensile test","methodology_en":"Tensile force Range: (0 – 5000) kN Tensile test Tensile force Range: (0 – 5000) kN Tensile test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła rozciągająca Zakres: (0 – 5000) kN Próba rozciągania Tensile force Range: (0 – 5000) kN Tensile test","reference":"PN-IEC 1089:1994 p. 6.5.3 PN-EN 50182:2002 p. 6.4.8 + Zał. C/ annex C IEC 62420:2008 p. 6.2.5 + Zał. B/ annex B PN-IEC 1089:1994 p. 6.6.4 PN-IEC 1089:1994 Zał. NA/annex NA p. 10.1 PN-IEC 1089:1994 Zał. NB/annex NB p. 10.2 PN-IEC 1089:1994 Zał. NC/annex NC p. 10","norm_bases":["PN-IEC 1089:1994 p. 6.5.3 PN-EN 50182:2002 p. 6.4.8 + Zał. C/ annex C IEC 62420:2008 p. 6.2.5 + Zał. B/ annex B PN-IEC 1089:1994 p. 6.6.4 PN-IEC 1089:1994 Zał. NA/annex NA p. 10.1 PN-IEC 1089:1994 Zał. NB/annex NB p. 10.2 PN-IEC 1089:1994 Zał. NC/annex NC p. 10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody wielodrutowe Stranded conductors Siła rozciągająca Zakres: (0 – 5000) kN Próba rozciągania Tensile force Range: (0 – 5000) kN Tensile test PN-IEC 1089:1994 p. 6.5.3 PN-EN 50182:2002 p. 6.4.8 + Zał. C/ annex C IEC 62420:2008 p. 6.2.5 + Zał. B/ annex B PN-IEC 1089:1994 p. 6.6.4 PN-IEC 1089:1994 Zał. NA/annex NA p. 10.1 PN-IEC 1089:1994 Zał. NB/annex NB p. 10.2 PN-IEC 1089:1994 Zał. NC/annex NC p. 10 Przewody wielodrutowe Stranded conductors Sila rozciagajaca Zakres: (0 – 5000) kN Proba rozciagania Tensile force Range: (0 – 5000) kN Tensile test PN-IEC 1089:1994 p. 6.5.3 PN-EN 50182:2002 p. 6.4.8 + Zal. C/ annex C IEC 62420:2008 p. 6.2.5 + Zal. B/ annex B PN-IEC 1089:1994 p. 6.6.4 PN-IEC 1089:1994 Zal. NA/annex NA p. 10.1 PN-IEC 1089:1994 Zal. NB/annex NB p. 10.2 PN-IEC 1089:1994 Zal. NC/annex NC p. 10","categories":["other"],"row_index":201,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Stranded conductors Tensile force Range: (0 – 5000) kN Tensile test Tensile force Range: (0 – 5000) kN Tensile test PN-IEC 1089:1994 p. 6.5.3 PN-EN 50182:2002 p. 6.4.8 + Zał. C/ annex C IEC 62420:2008 p. 6.2.5 + Zał. B/ annex B PN-IEC 1089:1994 p. 6.6.4 PN-IEC 1089:1994 Zał. NA/annex NA p. 10.1 PN-IEC 1089:1994 Zał. NB/annex NB p. 10.2 PN-IEC 1089:1994 Zał. NC/annex NC p. 10","search_zh":"绞合导线 Stranded conductors PN-IEC 1089:1994 p. 6.5.3 PN-EN 50182:2002 p. 6.4.8 + Zał. C/ annex C IEC 62420:2008 p. 6.2.5 + Zał. B/ annex B PN-IEC 1089:1994 p. 6.6.4 PN-IEC 1089:1994 Zał. NA/annex NA p. 10.1 PN-IEC 1089:1994 Zał. NB/annex NB p. 10.2 PN-IEC 1089:1994 Zał. NC/annex NC p. 10","test_object_zh":"绞合导线 Stranded conductors"},{"_id":"6a5a55ef9af9f73f38250b66","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Przewody wielodrutowe Stranded conductors","test_object_en":"Stranded conductors","methodology":"Wydłużenie Zakres: (0 – 2000) mm Metoda pomiaru bezpośredniego Elongation Range: (0 – 2000) mm Direct measurement method","methodology_en":"Elongation Range: (0 – 2000) mm Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wydłużenie Zakres: (0 – 2000) mm Metoda pomiaru bezpośredniego Elongation Range: (0 – 2000) mm Direct measurement method","reference":"PN-EN 50182:2002 p. 6.4.7 + Zał. C/ annex C IEC 62420:2008 Zał. B/annex B","norm_bases":["PN-EN 50182:2002 p. 6.4.7 + Zał. C/ annex C IEC 62420:2008 Zał. B/annex B"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody wielodrutowe Stranded conductors Wydłużenie Zakres: (0 – 2000) mm Metoda pomiaru bezpośredniego Elongation Range: (0 – 2000) mm Direct measurement method PN-EN 50182:2002 p. 6.4.7 + Zał. C/ annex C IEC 62420:2008 Zał. B/annex B Przewody wielodrutowe Stranded conductors Wydluzenie Zakres: (0 – 2000) mm Metoda pomiaru bezposredniego Elongation Range: (0 – 2000) mm Direct measurement method PN-EN 50182:2002 p. 6.4.7 + Zal. C/ annex C IEC 62420:2008 Zal. B/annex B","categories":["other"],"row_index":202,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Stranded conductors Elongation Range: (0 – 2000) mm Direct measurement method PN-EN 50182:2002 p. 6.4.7 + Zał. C/ annex C IEC 62420:2008 Zał. B/annex B","search_zh":"绞合导线 Stranded conductors 伸长 范围：(0 – 2000) mm 直接测量法 Elongation Range: (0 – 2000) mm Direct measurement method PN-EN 50182:2002 p. 6.4.7 + Zał. C/ annex C IEC 62420:2008 Zał. B/annex B","test_object_zh":"绞合导线 Stranded conductors","methodology_zh":"伸长 范围：(0 – 2000) mm 直接测量法 Elongation Range: (0 – 2000) mm Direct measurement method"},{"_id":"6a5a55ef9af9f73f38250b67","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Przewody wielodrutowe Stranded conductors","test_object_en":"Stranded conductors","methodology":"Średnica Zakres: (0 – 200) mm Metoda pomiaru bezpośredniego Diameter Range: (0 – 200) mm Direct measurement method","methodology_en":"Diameter Range: (0 – 200) mm Direct measurement method Diameter Range: (0 – 200) mm Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Średnica Zakres: (0 – 200) mm Metoda pomiaru bezpośredniego Diameter Range: (0 – 200) mm Direct measurement method","reference":"PN-IEC 1089:1994 p. 6.6.2 PN-EN 50182:2002 p. 6.4.2 PN-EN 50540:2010 p. 6.4.2 PN-IEC 1089:1994 Zał. NA/annex NA p. 5 PN-IEC 1089:1994 Zał. NB/annex NB p. 5 PN-IEC 1089:1994 Zał. NC/annex NC p. 5","norm_bases":["PN-IEC 1089:1994 p. 6.6.2 PN-EN 50182:2002 p. 6.4.2 PN-EN 50540:2010 p. 6.4.2 PN-IEC 1089:1994 Zał. NA/annex NA p. 5 PN-IEC 1089:1994 Zał. NB/annex NB p. 5 PN-IEC 1089:1994 Zał. NC/annex NC p. 5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody wielodrutowe Stranded conductors Średnica Zakres: (0 – 200) mm Metoda pomiaru bezpośredniego Diameter Range: (0 – 200) mm Direct measurement method PN-IEC 1089:1994 p. 6.6.2 PN-EN 50182:2002 p. 6.4.2 PN-EN 50540:2010 p. 6.4.2 PN-IEC 1089:1994 Zał. NA/annex NA p. 5 PN-IEC 1089:1994 Zał. NB/annex NB p. 5 PN-IEC 1089:1994 Zał. NC/annex NC p. 5 Przewody wielodrutowe Stranded conductors Srednica Zakres: (0 – 200) mm Metoda pomiaru bezposredniego Diameter Range: (0 – 200) mm Direct measurement method PN-IEC 1089:1994 p. 6.6.2 PN-EN 50182:2002 p. 6.4.2 PN-EN 50540:2010 p. 6.4.2 PN-IEC 1089:1994 Zal. NA/annex NA p. 5 PN-IEC 1089:1994 Zal. NB/annex NB p. 5 PN-IEC 1089:1994 Zal. NC/annex NC p. 5","categories":["other"],"row_index":203,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Stranded conductors Diameter Range: (0 – 200) mm Direct measurement method Diameter Range: (0 – 200) mm Direct measurement method PN-IEC 1089:1994 p. 6.6.2 PN-EN 50182:2002 p. 6.4.2 PN-EN 50540:2010 p. 6.4.2 PN-IEC 1089:1994 Zał. NA/annex NA p. 5 PN-IEC 1089:1994 Zał. NB/annex NB p. 5 PN-IEC 1089:1994 Zał. NC/annex NC p. 5","search_zh":"绞合导线 Stranded conductors PN-IEC 1089:1994 p. 6.6.2 PN-EN 50182:2002 p. 6.4.2 PN-EN 50540:2010 p. 6.4.2 PN-IEC 1089:1994 Zał. NA/annex NA p. 5 PN-IEC 1089:1994 Zał. NB/annex NB p. 5 PN-IEC 1089:1994 Zał. NC/annex NC p. 5","test_object_zh":"绞合导线 Stranded conductors"},{"_id":"6a5a55ef9af9f73f38250b68","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Przewody wielodrutowe Stranded conductors","test_object_en":"Stranded conductors","methodology":"Stosunek skrętu Zakres: (6 – 26) Metoda pomiaru bezpośredniego Lay ratio Range: (6 – 26) Direct measurement method","methodology_en":"Lay ratio Range: (6 – 26) Direct measurement method Lay ratio Range: (6 – 26) Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stosunek skrętu Zakres: (6 – 26) Metoda pomiaru bezpośredniego Lay ratio Range: (6 – 26) Direct measurement method","reference":"PN-IEC 1089:1994 p. 6.6.6 PN-EN 50182:2002 p. 6.4.4 PN-EN 50540:2010 p. 6.4.4 PN-EN 62219:2003 p. 6.6.6 PN-EN 62420:2008 p. 6.3.5","norm_bases":["PN-IEC 1089:1994 p. 6.6.6 PN-EN 50182:2002 p. 6.4.4 PN-EN 50540:2010 p. 6.4.4 PN-EN 62219:2003 p. 6.6.6 PN-EN 62420:2008 p. 6.3.5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody wielodrutowe Stranded conductors Stosunek skrętu Zakres: (6 – 26) Metoda pomiaru bezpośredniego Lay ratio Range: (6 – 26) Direct measurement method PN-IEC 1089:1994 p. 6.6.6 PN-EN 50182:2002 p. 6.4.4 PN-EN 50540:2010 p. 6.4.4 PN-EN 62219:2003 p. 6.6.6 PN-EN 62420:2008 p. 6.3.5 Przewody wielodrutowe Stranded conductors Stosunek skretu Zakres: (6 – 26) Metoda pomiaru bezposredniego Lay ratio Range: (6 – 26) Direct measurement method PN-IEC 1089:1994 p. 6.6.6 PN-EN 50182:2002 p. 6.4.4 PN-EN 50540:2010 p. 6.4.4 PN-EN 62219:2003 p. 6.6.6 PN-EN 62420:2008 p. 6.3.5","categories":["other"],"row_index":204,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Stranded conductors Lay ratio Range: (6 – 26) Direct measurement method Lay ratio Range: (6 – 26) Direct measurement method PN-IEC 1089:1994 p. 6.6.6 PN-EN 50182:2002 p. 6.4.4 PN-EN 50540:2010 p. 6.4.4 PN-EN 62219:2003 p. 6.6.6 PN-EN 62420:2008 p. 6.3.5","search_zh":"绞合导线 Stranded conductors PN-IEC 1089:1994 p. 6.6.6 PN-EN 50182:2002 p. 6.4.4 PN-EN 50540:2010 p. 6.4.4 PN-EN 62219:2003 p. 6.6.6 PN-EN 62420:2008 p. 6.3.5","test_object_zh":"绞合导线 Stranded conductors"},{"_id":"6a5a55ef9af9f73f38250b69","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Przewody wielodrutowe Stranded conductors","test_object_en":"Stranded conductors","methodology":"Kierunek skrętu Metoda badania wizualnego Lay direction Visual examination method","methodology_en":"Lay direction Visual examination method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Kierunek skrętu Metoda badania wizualnego Lay direction Visual examination method","reference":"PN-IEC 1089:1994 p. 6.6.6 PN-EN 50182:2002 p. 6.4.4 PN-EN 50540:2010 p. 6.4.4 PN-EN 62219:2003 p. 6.6.6 PN-EN 62420:2008 p. 6.3.5","norm_bases":["PN-IEC 1089:1994 p. 6.6.6 PN-EN 50182:2002 p. 6.4.4 PN-EN 50540:2010 p. 6.4.4 PN-EN 62219:2003 p. 6.6.6 PN-EN 62420:2008 p. 6.3.5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody wielodrutowe Stranded conductors Kierunek skrętu Metoda badania wizualnego Lay direction Visual examination method PN-IEC 1089:1994 p. 6.6.6 PN-EN 50182:2002 p. 6.4.4 PN-EN 50540:2010 p. 6.4.4 PN-EN 62219:2003 p. 6.6.6 PN-EN 62420:2008 p. 6.3.5 Przewody wielodrutowe Stranded conductors Kierunek skretu Metoda badania wizualnego Lay direction Visual examination method PN-IEC 1089:1994 p. 6.6.6 PN-EN 50182:2002 p. 6.4.4 PN-EN 50540:2010 p. 6.4.4 PN-EN 62219:2003 p. 6.6.6 PN-EN 62420:2008 p. 6.3.5","categories":["other"],"row_index":205,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Stranded conductors Lay direction Visual examination method PN-IEC 1089:1994 p. 6.6.6 PN-EN 50182:2002 p. 6.4.4 PN-EN 50540:2010 p. 6.4.4 PN-EN 62219:2003 p. 6.6.6 PN-EN 62420:2008 p. 6.3.5","search_zh":"绞合导线 Stranded conductors PN-IEC 1089:1994 p. 6.6.6 PN-EN 50182:2002 p. 6.4.4 PN-EN 50540:2010 p. 6.4.4 PN-EN 62219:2003 p. 6.6.6 PN-EN 62420:2008 p. 6.3.5","test_object_zh":"绞合导线 Stranded conductors"},{"_id":"6a5a55ef9af9f73f38250b6a","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Przewody wielodrutowe Stranded conductors","test_object_en":"Stranded conductors","methodology":"Bezwładność Metoda badania wizualnego Inertness Visual examination method","methodology_en":"Inertness Visual examination method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Bezwładność Metoda badania wizualnego Inertness Visual examination method","reference":"PN-EN 50182:2002 p. 6.4.3 PN-EN 50540:2010 p. 6.4.3","norm_bases":["PN-EN 50182:2002 p. 6.4.3 PN-EN 50540:2010 p. 6.4.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody wielodrutowe Stranded conductors Bezwładność Metoda badania wizualnego Inertness Visual examination method PN-EN 50182:2002 p. 6.4.3 PN-EN 50540:2010 p. 6.4.3 Przewody wielodrutowe Stranded conductors Bezwladnosc Metoda badania wizualnego Inertness Visual examination method PN-EN 50182:2002 p. 6.4.3 PN-EN 50540:2010 p. 6.4.3","categories":["other"],"row_index":206,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Stranded conductors Inertness Visual examination method PN-EN 50182:2002 p. 6.4.3 PN-EN 50540:2010 p. 6.4.3","search_zh":"绞合导线 Stranded conductors PN-EN 50182:2002 p. 6.4.3 PN-EN 50540:2010 p. 6.4.3","test_object_zh":"绞合导线 Stranded conductors"},{"_id":"6a5a55ef9af9f73f38250b6b","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Przewody wielodrutowe Stranded conductors","test_object_en":"Stranded conductors","methodology":"Liczba i rodzaj drutów Metoda badania wizualnego Number and type of wires Visual examination method","methodology_en":"Number and type of wires Visual examination method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba i rodzaj drutów Metoda badania wizualnego Number and type of wires Visual examination method","reference":"PN-EN 50182:2002 p. 6.4.5 PN-EN 50540:2010 p. 6.4.5","norm_bases":["PN-EN 50182:2002 p. 6.4.5 PN-EN 50540:2010 p. 6.4.5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody wielodrutowe Stranded conductors Liczba i rodzaj drutów Metoda badania wizualnego Number and type of wires Visual examination method PN-EN 50182:2002 p. 6.4.5 PN-EN 50540:2010 p. 6.4.5 Przewody wielodrutowe Stranded conductors Liczba i rodzaj drutow Metoda badania wizualnego Number and type of wires Visual examination method PN-EN 50182:2002 p. 6.4.5 PN-EN 50540:2010 p. 6.4.5","categories":["other"],"row_index":207,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Stranded conductors Number and type of wires Visual examination method PN-EN 50182:2002 p. 6.4.5 PN-EN 50540:2010 p. 6.4.5","search_zh":"绞合导线 Stranded conductors PN-EN 50182:2002 p. 6.4.5 PN-EN 50540:2010 p. 6.4.5","test_object_zh":"绞合导线 Stranded conductors"},{"_id":"6a5a55ef9af9f73f38250b6c","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Przewody wielodrutowe Stranded conductors","test_object_en":"Stranded conductors","methodology":"Jakość powierzchni Metoda badania wizualnego Surface condition Visual examination method","methodology_en":"Surface condition Visual examination method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Jakość powierzchni Metoda badania wizualnego Surface condition Visual examination method","reference":"PN-IEC 1089:1994 p. 6.6.5 PN-EN 50182:2002 p. 6.4.1 PN-EN 50540:2010 p. 6.4.1 PN-EN 62219:2003 p. 6.6.5 PN-EN 62420:2008 p. 6.3.4","norm_bases":["PN-IEC 1089:1994 p. 6.6.5 PN-EN 50182:2002 p. 6.4.1 PN-EN 50540:2010 p. 6.4.1 PN-EN 62219:2003 p. 6.6.5 PN-EN 62420:2008 p. 6.3.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody wielodrutowe Stranded conductors Jakość powierzchni Metoda badania wizualnego Surface condition Visual examination method PN-IEC 1089:1994 p. 6.6.5 PN-EN 50182:2002 p. 6.4.1 PN-EN 50540:2010 p. 6.4.1 PN-EN 62219:2003 p. 6.6.5 PN-EN 62420:2008 p. 6.3.4 Przewody wielodrutowe Stranded conductors Jakosc powierzchni Metoda badania wizualnego Surface condition Visual examination method PN-IEC 1089:1994 p. 6.6.5 PN-EN 50182:2002 p. 6.4.1 PN-EN 50540:2010 p. 6.4.1 PN-EN 62219:2003 p. 6.6.5 PN-EN 62420:2008 p. 6.3.4","categories":["other"],"row_index":208,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Stranded conductors Surface condition Visual examination method PN-IEC 1089:1994 p. 6.6.5 PN-EN 50182:2002 p. 6.4.1 PN-EN 50540:2010 p. 6.4.1 PN-EN 62219:2003 p. 6.6.5 PN-EN 62420:2008 p. 6.3.4","search_zh":"绞合导线 Stranded conductors PN-IEC 1089:1994 p. 6.6.5 PN-EN 50182:2002 p. 6.4.1 PN-EN 50540:2010 p. 6.4.1 PN-EN 62219:2003 p. 6.6.5 PN-EN 62420:2008 p. 6.3.4","test_object_zh":"绞合导线 Stranded conductors"},{"_id":"6a5a55ef9af9f73f38250b6d","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Przewody wielodrutowe Stranded conductors","test_object_en":"Stranded conductors","methodology":"Masa jednostkowa długości Masa smaru Zakres: (0 – 50) kg/m Metoda pomiaru bezpośredniego Mass per unit length Mass of grease Range: (0 – 50) kg/m Direct measurement method","methodology_en":"Mass per unit length Mass of grease Range: (0 – 50) kg/m Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Masa jednostkowa długości Masa smaru Zakres: (0 – 50) kg/m Metoda pomiaru bezpośredniego Mass per unit length Mass of grease Range: (0 – 50) kg/m Direct measurement method","reference":"PN-IEC 1089:1994 p. 6.6.3+Zał. C/ annex C PN-EN 50182:2002 p. 6.4.6+Zał. B/ annex B PN-EN 50540:2010 p. 6.4.7 PN-EN 62219:2003 p. 6.6.3+Zał. C/ annex C PN-EN 62420:2008 p. 6.3.3+Zał. C/ annex C","norm_bases":["PN-IEC 1089:1994 p. 6.6.3+Zał. C/ annex C PN-EN 50182:2002 p. 6.4.6+Zał. B/ annex B PN-EN 50540:2010 p. 6.4.7 PN-EN 62219:2003 p. 6.6.3+Zał. C/ annex C PN-EN 62420:2008 p. 6.3.3+Zał. C/ annex C"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody wielodrutowe Stranded conductors Masa jednostkowa długości Masa smaru Zakres: (0 – 50) kg/m Metoda pomiaru bezpośredniego Mass per unit length Mass of grease Range: (0 – 50) kg/m Direct measurement method PN-IEC 1089:1994 p. 6.6.3+Zał. C/ annex C PN-EN 50182:2002 p. 6.4.6+Zał. B/ annex B PN-EN 50540:2010 p. 6.4.7 PN-EN 62219:2003 p. 6.6.3+Zał. C/ annex C PN-EN 62420:2008 p. 6.3.3+Zał. C/ annex C Przewody wielodrutowe Stranded conductors Masa jednostkowa dlugosci Masa smaru Zakres: (0 – 50) kg/m Metoda pomiaru bezposredniego Mass per unit length Mass of grease Range: (0 – 50) kg/m Direct measurement method PN-IEC 1089:1994 p. 6.6.3+Zal. C/ annex C PN-EN 50182:2002 p. 6.4.6+Zal. B/ annex B PN-EN 50540:2010 p. 6.4.7 PN-EN 62219:2003 p. 6.6.3+Zal. C/ annex C PN-EN 62420:2008 p. 6.3.3+Zal. C/ annex C","categories":["petro"],"row_index":209,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Stranded conductors Mass per unit length Mass of grease Range: (0 – 50) kg/m Direct measurement method PN-IEC 1089:1994 p. 6.6.3+Zał. C/ annex C PN-EN 50182:2002 p. 6.4.6+Zał. B/ annex B PN-EN 50540:2010 p. 6.4.7 PN-EN 62219:2003 p. 6.6.3+Zał. C/ annex C PN-EN 62420:2008 p. 6.3.3+Zał. C/ annex C","search_zh":"绞合导线 Stranded conductors PN-IEC 1089:1994 p. 6.6.3+Zał. C/ annex C PN-EN 50182:2002 p. 6.4.6+Zał. B/ annex B PN-EN 50540:2010 p. 6.4.7 PN-EN 62219:2003 p. 6.6.3+Zał. C/ annex C PN-EN 62420:2008 p. 6.3.3+Zał. C/ annex C","test_object_zh":"绞合导线 Stranded conductors"},{"_id":"6a5a55ef9af9f73f38250b6e","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Przewody wielodrutowe Stranded conductors","test_object_en":"Stranded conductors","methodology":"Pole przekroju Metoda pomiaru bezpośredniego Cross-sectional area Direct measurement method","methodology_en":"Cross-sectional area Direct measurement method Cross-sectional area Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pole przekroju Metoda pomiaru bezpośredniego Cross-sectional area Direct measurement method","reference":"PN-IEC 1089:1994 p. 6.6.1 PN-EN 50540:2010 p. 6.4.6 PN-EN 62219:2003 p. 6.6.1 PN-EN 62420:2008 p. 6.3.1","norm_bases":["PN-IEC 1089:1994 p. 6.6.1 PN-EN 50540:2010 p. 6.4.6 PN-EN 62219:2003 p. 6.6.1 PN-EN 62420:2008 p. 6.3.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody wielodrutowe Stranded conductors Pole przekroju Metoda pomiaru bezpośredniego Cross-sectional area Direct measurement method PN-IEC 1089:1994 p. 6.6.1 PN-EN 50540:2010 p. 6.4.6 PN-EN 62219:2003 p. 6.6.1 PN-EN 62420:2008 p. 6.3.1 Przewody wielodrutowe Stranded conductors Pole przekroju Metoda pomiaru bezposredniego Cross-sectional area Direct measurement method PN-IEC 1089:1994 p. 6.6.1 PN-EN 50540:2010 p. 6.4.6 PN-EN 62219:2003 p. 6.6.1 PN-EN 62420:2008 p. 6.3.1","categories":["other"],"row_index":210,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Stranded conductors Cross-sectional area Direct measurement method Cross-sectional area Direct measurement method PN-IEC 1089:1994 p. 6.6.1 PN-EN 50540:2010 p. 6.4.6 PN-EN 62219:2003 p. 6.6.1 PN-EN 62420:2008 p. 6.3.1","search_zh":"绞合导线 Stranded conductors PN-IEC 1089:1994 p. 6.6.1 PN-EN 50540:2010 p. 6.4.6 PN-EN 62219:2003 p. 6.6.1 PN-EN 62420:2008 p. 6.3.1","test_object_zh":"绞合导线 Stranded conductors"},{"_id":"6a5a55ef9af9f73f38250b6f","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Przewody wielodrutowe Stranded conductors","test_object_en":"Stranded conductors","methodology":"Współczynnik wyślizgu Próba wyślizgu Slippage factor Slippage test","methodology_en":"Slippage factor Slippage test Slippage factor Slippage test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Współczynnik wyślizgu Próba wyślizgu Slippage factor Slippage test","reference":"PN-EN 50397-1:2021-04 Zał. C / annex C","norm_bases":["PN-EN 50397-1:2021-04 Zał. C / annex C"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody wielodrutowe Stranded conductors Współczynnik wyślizgu Próba wyślizgu Slippage factor Slippage test PN-EN 50397-1:2021-04 Zał. C / annex C Przewody wielodrutowe Stranded conductors Wspolczynnik wyslizgu Proba wyslizgu Slippage factor Slippage test PN-EN 50397-1:2021-04 Zal. C / annex C","categories":["other"],"row_index":211,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Stranded conductors Slippage factor Slippage test Slippage factor Slippage test PN-EN 50397-1:2021-04 Zał. C / annex C","search_zh":"绞合导线 Stranded conductors PN-EN 50397-1:2021-04 Zał. C / annex C","test_object_zh":"绞合导线 Stranded conductors"},{"_id":"6a5a55ef9af9f73f38250b70","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Przewody wielodrutowe Stranded conductors","test_object_en":"Stranded conductors","methodology":"Wyznaczanie tłumienności własnej przewodu Metody wibracyjne Zakres: (0 – 2000) Hz Determination of conductor self- damping Vibration method Range: (0 – 2000) Hz","methodology_en":"Determination of conductor self- damping Vibration method Range: (0 – 2000) Hz","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wyznaczanie tłumienności własnej przewodu Metody wibracyjne Zakres: (0 – 2000) Hz Determination of conductor self- damping Vibration method Range: (0 – 2000) Hz","reference":"PN-EN 62567:2014-04 p. 8.2 PN-EN 62567:2014-04 p. 8.3","norm_bases":["PN-EN 62567:2014-04 p. 8.2 PN-EN 62567:2014-04 p. 8.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody wielodrutowe Stranded conductors Wyznaczanie tłumienności własnej przewodu Metody wibracyjne Zakres: (0 – 2000) Hz Determination of conductor self- damping Vibration method Range: (0 – 2000) Hz PN-EN 62567:2014-04 p. 8.2 PN-EN 62567:2014-04 p. 8.3 Przewody wielodrutowe Stranded conductors Wyznaczanie tlumiennosci wlasnej przewodu Metody wibracyjne Zakres: (0 – 2000) Hz Determination of conductor self- damping Vibration method Range: (0 – 2000) Hz PN-EN 62567:2014-04 p. 8.2 PN-EN 62567:2014-04 p. 8.3","categories":["other"],"row_index":212,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Stranded conductors Determination of conductor self- damping Vibration method Range: (0 – 2000) Hz PN-EN 62567:2014-04 p. 8.2 PN-EN 62567:2014-04 p. 8.3","search_zh":"绞合导线 Stranded conductors PN-EN 62567:2014-04 p. 8.2 PN-EN 62567:2014-04 p. 8.3","test_object_zh":"绞合导线 Stranded conductors"},{"_id":"6a5a55ef9af9f73f38250b71","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odstępniki Spacers","test_object_en":"Spacers","methodology":"Kontrola wizualna Metoda badania wizualnego Visual examination Visual examination method","methodology_en":"Visual examination Visual examination method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Kontrola wizualna Metoda badania wizualnego Visual examination Visual examination method","reference":"PN-EN IEC 61854:2020-11 p 7.1","norm_bases":["PN-EN IEC 61854:2020-11 p 7.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odstępniki Spacers Kontrola wizualna Metoda badania wizualnego Visual examination Visual examination method PN-EN IEC 61854:2020-11 p 7.1 Odstepniki Spacers Kontrola wizualna Metoda badania wizualnego Visual examination Visual examination method PN-EN IEC 61854:2020-11 p 7.1","categories":["other"],"row_index":213,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Spacers Visual examination Visual examination method PN-EN IEC 61854:2020-11 p 7.1","search_zh":"间隔棒 Spacers PN-EN IEC 61854:2020-11 p 7.1","test_object_zh":"间隔棒 Spacers"},{"_id":"6a5a55ef9af9f73f38250b72","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odstępniki Spacers","test_object_en":"Spacers","methodology":"Sprawdzenie wymiarów, materiału i masy Metoda pomiaru bezpośredniego Zakres: wymiary (0 – 2000) mm masa (0 – 60) kg Verification of dimensions, materials and mass Direct measurement method Range: dimensions (0 – 2000) mm mass (0 – 60) kg","methodology_en":"Verification of dimensions, materials and mass Direct measurement method Range: dimensions (0 – 2000) mm mass (0 – 60) kg","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sprawdzenie wymiarów, materiału i masy Metoda pomiaru bezpośredniego Zakres: wymiary (0 – 2000) mm masa (0 – 60) kg Verification of dimensions, materials and mass Direct measurement method Range: dimensions (0 – 2000) mm mass (0 – 60) kg","reference":"PN-EN IEC 61854:2020-11 p. 7.2","norm_bases":["PN-EN IEC 61854:2020-11 p. 7.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odstępniki Spacers Sprawdzenie wymiarów, materiału i masy Metoda pomiaru bezpośredniego Zakres: wymiary (0 – 2000) mm masa (0 – 60) kg Verification of dimensions, materials and mass Direct measurement method Range: dimensions (0 – 2000) mm mass (0 – 60) kg PN-EN IEC 61854:2020-11 p. 7.2 Odstepniki Spacers Sprawdzenie wymiarow, materialu i masy Metoda pomiaru bezposredniego Zakres: wymiary (0 – 2000) mm masa (0 – 60) kg Verification of dimensions, materials and mass Direct measurement method Range: dimensions (0 – 2000) mm mass (0 – 60) kg PN-EN IEC 61854:2020-11 p. 7.2","categories":["materials"],"row_index":214,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Spacers Verification of dimensions, materials and mass Direct measurement method Range: dimensions (0 – 2000) mm mass (0 – 60) kg PN-EN IEC 61854:2020-11 p. 7.2","search_zh":"间隔棒 Spacers PN-EN IEC 61854:2020-11 p. 7.2","test_object_zh":"间隔棒 Spacers"},{"_id":"6a5a55ef9af9f73f38250b73","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odstępniki Spacers","test_object_en":"Spacers","methodology":"Kontrola powłoki cynkowej Metoda pomiaru bezpośredniego Zakres: grubość powłoki (0 – 500) µm Corrosion protection test Direct measurement method Range: coating thickness (0 – 500) µm","methodology_en":"Zinc coating inspection Direct measurement method Range: coating thickness (0 – 500) µm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Kontrola powłoki cynkowej Metoda pomiaru bezpośredniego Zakres: grubość powłoki (0 – 500) µm Corrosion protection test Direct measurement method Range: coating thickness (0 – 500) µm","reference":"PN-EN IEC 61854:2020-11 p. 7.3.1 PN-EN ISO 1461:2011 tab./tables 3 i/and 4","norm_bases":["PN-EN IEC 61854:2020-11 p. 7.3.1 PN-EN ISO 1461:2011 tab./tables 3 i/and 4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odstępniki Spacers Kontrola powłoki cynkowej Metoda pomiaru bezpośredniego Zakres: grubość powłoki (0 – 500) µm Corrosion protection test Direct measurement method Range: coating thickness (0 – 500) µm PN-EN IEC 61854:2020-11 p. 7.3.1 PN-EN ISO 1461:2011 tab./tables 3 i/and 4 Odstepniki Spacers Kontrola powloki cynkowej Metoda pomiaru bezposredniego Zakres: grubosc powloki (0 – 500) µm Corrosion protection test Direct measurement method Range: coating thickness (0 – 500) µm PN-EN IEC 61854:2020-11 p. 7.3.1 PN-EN ISO 1461:2011 tab./tables 3 i/and 4","categories":["other"],"row_index":215,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Spacers Zinc coating inspection Direct measurement method Range: coating thickness (0 – 500) µm PN-EN IEC 61854:2020-11 p. 7.3.1 PN-EN ISO 1461:2011 tab./tables 3 i/and 4","search_zh":"间隔棒 Spacers PN-EN IEC 61854:2020-11 p. 7.3.1 PN-EN ISO 1461:2011 tab./tables 3 i/and 4","test_object_zh":"间隔棒 Spacers"},{"_id":"6a5a55ef9af9f73f38250b74","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odstępniki Spacers","test_object_en":"Spacers","methodology":"Próba poślizgu zacisku Zakres: siła poślizgu (0 – 50) kN Clamp slip test Range: slip force (0 – 50) kN","methodology_en":"Clamp slip test Range: slip force (0 – 50) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Próba poślizgu zacisku Zakres: siła poślizgu (0 – 50) kN Clamp slip test Range: slip force (0 – 50) kN","reference":"PN-EN IEC 61854:2020-11 p. 7.5.1","norm_bases":["PN-EN IEC 61854:2020-11 p. 7.5.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odstępniki Spacers Próba poślizgu zacisku Zakres: siła poślizgu (0 – 50) kN Clamp slip test Range: slip force (0 – 50) kN PN-EN IEC 61854:2020-11 p. 7.5.1 Odstepniki Spacers Proba poslizgu zacisku Zakres: sila poslizgu (0 – 50) kN Clamp slip test Range: slip force (0 – 50) kN PN-EN IEC 61854:2020-11 p. 7.5.1","categories":["other"],"row_index":216,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Spacers Clamp slip test Range: slip force (0 – 50) kN PN-EN IEC 61854:2020-11 p. 7.5.1","search_zh":"间隔棒 Spacers PN-EN IEC 61854:2020-11 p. 7.5.1","test_object_zh":"间隔棒 Spacers"},{"_id":"6a5a55ef9af9f73f38250b75","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odstępniki Spacers","test_object_en":"Spacers","methodology":"Próba dokręcania śrub zacisku Zakres: Moment dokręcania (0 – 340) Nm Clamp bolt tightening test Range: torque (0 – 340) Nm","methodology_en":"Clamp bolt tightening test Range: torque (0 – 340) Nm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Próba dokręcania śrub zacisku Zakres: Moment dokręcania (0 – 340) Nm Clamp bolt tightening test Range: torque (0 – 340) Nm","reference":"PN-EN IEC 61854:2020-11 p. 7.5.2","norm_bases":["PN-EN IEC 61854:2020-11 p. 7.5.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odstępniki Spacers Próba dokręcania śrub zacisku Zakres: Moment dokręcania (0 – 340) Nm Clamp bolt tightening test Range: torque (0 – 340) Nm PN-EN IEC 61854:2020-11 p. 7.5.2 Odstepniki Spacers Proba dokrecania srub zacisku Zakres: Moment dokrecania (0 – 340) Nm Clamp bolt tightening test Range: torque (0 – 340) Nm PN-EN IEC 61854:2020-11 p. 7.5.2","categories":["other"],"row_index":217,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Spacers Clamp bolt tightening test Range: torque (0 – 340) Nm PN-EN IEC 61854:2020-11 p. 7.5.2","search_zh":"间隔棒 Spacers PN-EN IEC 61854:2020-11 p. 7.5.2","test_object_zh":"间隔棒 Spacers"},{"_id":"6a5a55ef9af9f73f38250b76","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odstępniki Spacers","test_object_en":"Spacers","methodology":"Próba ściskania i rozciągania Metoda obciążania siłą Zakres: siła (0 – 5000) kN Compression and tension tests Force method Range: force (0 – 5000) kN","methodology_en":"Compression and tension tests Force method Range: force (0 – 5000) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Próba ściskania i rozciągania Metoda obciążania siłą Zakres: siła (0 – 5000) kN Compression and tension tests Force method Range: force (0 – 5000) kN","reference":"PN-EN IEC 61854:2020-11 p. 7.5.3","norm_bases":["PN-EN IEC 61854:2020-11 p. 7.5.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odstępniki Spacers Próba ściskania i rozciągania Metoda obciążania siłą Zakres: siła (0 – 5000) kN Compression and tension tests Force method Range: force (0 – 5000) kN PN-EN IEC 61854:2020-11 p. 7.5.3 Odstepniki Spacers Proba sciskania i rozciagania Metoda obciazania sila Zakres: sila (0 – 5000) kN Compression and tension tests Force method Range: force (0 – 5000) kN PN-EN IEC 61854:2020-11 p. 7.5.3","categories":["other"],"row_index":218,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Spacers Compression and tension tests Force method Range: force (0 – 5000) kN PN-EN IEC 61854:2020-11 p. 7.5.3","search_zh":"间隔棒 Spacers PN-EN IEC 61854:2020-11 p. 7.5.3","test_object_zh":"间隔棒 Spacers"},{"_id":"6a5a55ef9af9f73f38250b77","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odstępniki Spacers","test_object_en":"Spacers","methodology":"Test elastyczności Metoda pomiaru bezpośredniego Zakres: Przemieszczenia liniowe (0 – 300) mm Przemieszczenia kątowe (0 – 360) º Flexibility tests Direct measurement method Range: linear displacement (0 – 300) mm angular displacement (0 – 360) º","methodology_en":"Flexibility tests Direct measurement method Range: linear displacement (0 – 300) mm angular displacement (0 – 360) º","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Test elastyczności Metoda pomiaru bezpośredniego Zakres: Przemieszczenia liniowe (0 – 300) mm Przemieszczenia kątowe (0 – 360) º Flexibility tests Direct measurement method Range: linear displacement (0 – 300) mm angular displacement (0 – 360) º","reference":"PN-EN IEC 61854:2020-11 p. 7.5.5","norm_bases":["PN-EN IEC 61854:2020-11 p. 7.5.5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odstępniki Spacers Test elastyczności Metoda pomiaru bezpośredniego Zakres: Przemieszczenia liniowe (0 – 300) mm Przemieszczenia kątowe (0 – 360) º Flexibility tests Direct measurement method Range: linear displacement (0 – 300) mm angular displacement (0 – 360) º PN-EN IEC 61854:2020-11 p. 7.5.5 Odstepniki Spacers Test elastycznosci Metoda pomiaru bezposredniego Zakres: Przemieszczenia liniowe (0 – 300) mm Przemieszczenia katowe (0 – 360) º Flexibility tests Direct measurement method Range: linear displacement (0 – 300) mm angular displacement (0 – 360) º PN-EN IEC 61854:2020-11 p. 7.5.5","categories":["other"],"row_index":219,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Spacers Flexibility tests Direct measurement method Range: linear displacement (0 – 300) mm angular displacement (0 – 360) º PN-EN IEC 61854:2020-11 p. 7.5.5","search_zh":"间隔棒 Spacers PN-EN IEC 61854:2020-11 p. 7.5.5","test_object_zh":"间隔棒 Spacers"},{"_id":"6a5a55ef9af9f73f38250b78","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odstępniki Spacers","test_object_en":"Spacers","methodology":"Metoda sztywności Zakres: (0 – 10) kN Metoda obciążania siłą Stiffness method Range: (0 – 10) kN Force loading method","methodology_en":"Stiffness method Range: (0 – 10) kN Force loading method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Metoda sztywności Zakres: (0 – 10) kN Metoda obciążania siłą Stiffness method Range: (0 – 10) kN Force loading method","reference":"PN-EN IEC 61854:2020-11 p. 7.5.4. b)","norm_bases":["PN-EN IEC 61854:2020-11 p. 7.5.4. b)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odstępniki Spacers Metoda sztywności Zakres: (0 – 10) kN Metoda obciążania siłą Stiffness method Range: (0 – 10) kN Force loading method PN-EN IEC 61854:2020-11 p. 7.5.4. b) Odstepniki Spacers Metoda sztywnosci Zakres: (0 – 10) kN Metoda obciazania sila Stiffness method Range: (0 – 10) kN Force loading method PN-EN IEC 61854:2020-11 p. 7.5.4. b)","categories":["other"],"row_index":220,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Spacers Stiffness method Range: (0 – 10) kN Force loading method PN-EN IEC 61854:2020-11 p. 7.5.4. b)","search_zh":"间隔棒 Spacers PN-EN IEC 61854:2020-11 p. 7.5.4. b)","test_object_zh":"间隔棒 Spacers"},{"_id":"6a5a55ef9af9f73f38250b79","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odstępniki Spacers","test_object_en":"Spacers","methodology":"Metoda tłumienia Metoda pomiaru bezpośredniego Metoda obliczeniowa Damping method Direct measurement method Calculation method","methodology_en":"Damping method Direct measurement method Calculation method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Metoda tłumienia Metoda pomiaru bezpośredniego Metoda obliczeniowa Damping method Direct measurement method Calculation method","reference":"PN-EN IEC 61854:2020-11 p. 7.5.4. c)","norm_bases":["PN-EN IEC 61854:2020-11 p. 7.5.4. c)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odstępniki Spacers Metoda tłumienia Metoda pomiaru bezpośredniego Metoda obliczeniowa Damping method Direct measurement method Calculation method PN-EN IEC 61854:2020-11 p. 7.5.4. c) Odstepniki Spacers Metoda tlumienia Metoda pomiaru bezposredniego Metoda obliczeniowa Damping method Direct measurement method Calculation method PN-EN IEC 61854:2020-11 p. 7.5.4. c)","categories":["other"],"row_index":221,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Spacers Damping method Direct measurement method Calculation method PN-EN IEC 61854:2020-11 p. 7.5.4. c)","search_zh":"间隔棒 Spacers PN-EN IEC 61854:2020-11 p. 7.5.4. c)","test_object_zh":"间隔棒 Spacers"},{"_id":"6a5a55ef9af9f73f38250b7a","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Druty stalowe Steel wires","test_object_en":"Steel wires","methodology":"Naprężenie przy 1% wydłużeniu Metoda obciążania siłą Zakres: siła (0 – 300) kN Stress at 1% extension Force method Range: force (0 – 300) kN","methodology_en":"Stress at 1% extension Force loading method Range: force (0 – 300) kN Stress at 1% extension Force method Range: force (0 – 300) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Naprężenie przy 1% wydłużeniu Metoda obciążania siłą Zakres: siła (0 – 300) kN Stress at 1% extension Force method Range: force (0 – 300) kN","reference":"PN-EN IEC 63248:2022-12 p. 7.4.3","norm_bases":["PN-EN IEC 63248:2022-12 p. 7.4.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Druty stalowe Steel wires Naprężenie przy 1% wydłużeniu Metoda obciążania siłą Zakres: siła (0 – 300) kN Stress at 1% extension Force method Range: force (0 – 300) kN PN-EN IEC 63248:2022-12 p. 7.4.3 Druty stalowe Steel wires Naprezenie przy 1% wydluzeniu Metoda obciazania sila Zakres: sila (0 – 300) kN Stress at 1% extension Force method Range: force (0 – 300) kN PN-EN IEC 63248:2022-12 p. 7.4.3","categories":["materials"],"row_index":222,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Steel wires Stress at 1% extension Force loading method Range: force (0 – 300) kN Stress at 1% extension Force method Range: force (0 – 300) kN PN-EN IEC 63248:2022-12 p. 7.4.3","search_zh":"钢丝 Steel wires PN-EN IEC 63248:2022-12 p. 7.4.3","test_object_zh":"钢丝 Steel wires"},{"_id":"6a5a55ef9af9f73f38250b7b","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Druty stalowe Steel wires","test_object_en":"Steel wires","methodology":"Masa powłoki cynkowej Metoda gazowo-objętościowa Weight of zinc coating Gaseous volumetric method","methodology_en":"Weight of zinc coating Gaseous volumetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Masa powłoki cynkowej Metoda gazowo-objętościowa Weight of zinc coating Gaseous volumetric method","reference":"PN-EN 10244-2:2010 p. 5.2.3","norm_bases":["PN-EN 10244-2:2010 p. 5.2.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Druty stalowe Steel wires Masa powłoki cynkowej Metoda gazowo-objętościowa Weight of zinc coating Gaseous volumetric method PN-EN 10244-2:2010 p. 5.2.3 Druty stalowe Steel wires Masa powloki cynkowej Metoda gazowo-objetosciowa Weight of zinc coating Gaseous volumetric method PN-EN 10244-2:2010 p. 5.2.3","categories":["materials"],"row_index":223,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Steel wires Weight of zinc coating Gaseous volumetric method PN-EN 10244-2:2010 p. 5.2.3","search_zh":"钢丝 Steel wires PN-EN 10244-2:2010 p. 5.2.3","test_object_zh":"钢丝 Steel wires"},{"_id":"6a5a55ef9af9f73f38250b7c","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Druty stalowe Steel wires","test_object_en":"Steel wires","methodology":"Ciągłość powłoki cynkowej Ocena wizualna Próba zanurzeniowa Uniformity of zinc coating Visual examination Dipping test","methodology_en":"Uniformity of zinc coating Visual examination Dipping test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciągłość powłoki cynkowej Ocena wizualna Próba zanurzeniowa Uniformity of zinc coating Visual examination Dipping test","reference":"PN-EN 10244-2:2010 p. 5.3","norm_bases":["PN-EN 10244-2:2010 p. 5.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Druty stalowe Steel wires Ciągłość powłoki cynkowej Ocena wizualna Próba zanurzeniowa Uniformity of zinc coating Visual examination Dipping test PN-EN 10244-2:2010 p. 5.3 Druty stalowe Steel wires Ciaglosc powloki cynkowej Ocena wizualna Proba zanurzeniowa Uniformity of zinc coating Visual examination Dipping test PN-EN 10244-2:2010 p. 5.3","categories":["materials"],"row_index":224,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Steel wires Uniformity of zinc coating Visual examination Dipping test PN-EN 10244-2:2010 p. 5.3","search_zh":"钢丝 Steel wires PN-EN 10244-2:2010 p. 5.3","test_object_zh":"钢丝 Steel wires"},{"_id":"6a5a55ef9af9f73f38250b7d","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Druty Wires","test_object_en":"Wires","methodology":"Średnica Zakres: (0 – 200) mm Metoda pomiaru bezpośredniego Diameter Range: (0 – 200) mm Direct measurement method","methodology_en":"Diameter Range: (0 – 200) mm Direct measurement method Diameter Range: (0 – 200) mm Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Średnica Zakres: (0 – 200) mm Metoda pomiaru bezpośredniego Diameter Range: (0 – 200) mm Direct measurement method","reference":"PN-EN IEC 62641:2022-12 p. 6.4.2 PN-EN IEC 63248:2022-12 p. 7.4.2 PN-EN IEC 62641:2022-12 p. 6.4.1","norm_bases":["PN-EN IEC 62641:2022-12 p. 6.4.2 PN-EN IEC 63248:2022-12 p. 7.4.2 PN-EN IEC 62641:2022-12 p. 6.4.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Druty Wires Średnica Zakres: (0 – 200) mm Metoda pomiaru bezpośredniego Diameter Range: (0 – 200) mm Direct measurement method PN-EN IEC 62641:2022-12 p. 6.4.2 PN-EN IEC 63248:2022-12 p. 7.4.2 PN-EN IEC 62641:2022-12 p. 6.4.1 Druty Wires Srednica Zakres: (0 – 200) mm Metoda pomiaru bezposredniego Diameter Range: (0 – 200) mm Direct measurement method PN-EN IEC 62641:2022-12 p. 6.4.2 PN-EN IEC 63248:2022-12 p. 7.4.2 PN-EN IEC 62641:2022-12 p. 6.4.1","categories":["other"],"row_index":225,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wires Diameter Range: (0 – 200) mm Direct measurement method Diameter Range: (0 – 200) mm Direct measurement method PN-EN IEC 62641:2022-12 p. 6.4.2 PN-EN IEC 63248:2022-12 p. 7.4.2 PN-EN IEC 62641:2022-12 p. 6.4.1","search_zh":"钢丝 Wires PN-EN IEC 62641:2022-12 p. 6.4.2 PN-EN IEC 63248:2022-12 p. 7.4.2 PN-EN IEC 62641:2022-12 p. 6.4.1","test_object_zh":"钢丝 Wires"},{"_id":"6a5a55ef9af9f73f38250b7e","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Druty Wires","test_object_en":"Wires","methodology":"Siła rozciągająca Zakres: (0 – 100) kN Próba rozciągania Tensile force Range: (0 – 100) kN Tensile test","methodology_en":"Tensile force Range: (0 – 100) kN Tensile test Tensile force Range: (0 – 100) kN Tensile test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła rozciągająca Zakres: (0 – 100) kN Próba rozciągania Tensile force Range: (0 – 100) kN Tensile test","reference":"PN-EN IEC 62641:2022-12 p. 6.4.3 PN-EN IEC 63248:2022-12 p. 7.4.3 CEI IEC 62219:2002 p. 6.6.4","norm_bases":["PN-EN IEC 62641:2022-12 p. 6.4.3 PN-EN IEC 63248:2022-12 p. 7.4.3 CEI IEC 62219:2002 p. 6.6.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Druty Wires Siła rozciągająca Zakres: (0 – 100) kN Próba rozciągania Tensile force Range: (0 – 100) kN Tensile test PN-EN IEC 62641:2022-12 p. 6.4.3 PN-EN IEC 63248:2022-12 p. 7.4.3 CEI IEC 62219:2002 p. 6.6.4 Druty Wires Sila rozciagajaca Zakres: (0 – 100) kN Proba rozciagania Tensile force Range: (0 – 100) kN Tensile test PN-EN IEC 62641:2022-12 p. 6.4.3 PN-EN IEC 63248:2022-12 p. 7.4.3 CEI IEC 62219:2002 p. 6.6.4","categories":["other"],"row_index":226,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wires Tensile force Range: (0 – 100) kN Tensile test Tensile force Range: (0 – 100) kN Tensile test PN-EN IEC 62641:2022-12 p. 6.4.3 PN-EN IEC 63248:2022-12 p. 7.4.3 CEI IEC 62219:2002 p. 6.6.4","search_zh":"钢丝 Wires PN-EN IEC 62641:2022-12 p. 6.4.3 PN-EN IEC 63248:2022-12 p. 7.4.3 CEI IEC 62219:2002 p. 6.6.4","test_object_zh":"钢丝 Wires"},{"_id":"6a5a55ef9af9f73f38250b7f","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Druty Wires","test_object_en":"Wires","methodology":"Wydłużenie Zakres: (0 – 2000) mm Metoda pomiaru bezpośredniego Elongation Range: (0 – 2000) mm Direct measurement method","methodology_en":"Elongation Range: (0 – 2000) mm Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wydłużenie Zakres: (0 – 2000) mm Metoda pomiaru bezpośredniego Elongation Range: (0 – 2000) mm Direct measurement method","reference":"PN-EN IEC 62641:2022-12 p. 6.4.4","norm_bases":["PN-EN IEC 62641:2022-12 p. 6.4.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Druty Wires Wydłużenie Zakres: (0 – 2000) mm Metoda pomiaru bezpośredniego Elongation Range: (0 – 2000) mm Direct measurement method PN-EN IEC 62641:2022-12 p. 6.4.4 Druty Wires Wydluzenie Zakres: (0 – 2000) mm Metoda pomiaru bezposredniego Elongation Range: (0 – 2000) mm Direct measurement method PN-EN IEC 62641:2022-12 p. 6.4.4","categories":["other"],"row_index":227,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wires Elongation Range: (0 – 2000) mm Direct measurement method PN-EN IEC 62641:2022-12 p. 6.4.4","search_zh":"钢丝 Wires 伸长 范围：(0 – 2000) mm 直接测量法 Elongation Range: (0 – 2000) mm Direct measurement method PN-EN IEC 62641:2022-12 p. 6.4.4","test_object_zh":"钢丝 Wires","methodology_zh":"伸长 范围：(0 – 2000) mm 直接测量法 Elongation Range: (0 – 2000) mm Direct measurement method"},{"_id":"6a5a55ef9af9f73f38250b80","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Druty Wires","test_object_en":"Wires","methodology":"Zdolność do nawijania Próba nawijania Ability for wrapping Wrapping test","methodology_en":"Ability for wrapping Wrapping test Ability for wrapping Wrapping test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność do nawijania Próba nawijania Ability for wrapping Wrapping test","reference":"PN-EN 50182:2002 p. 6.5.2 PN-EN IEC 62641:2022-12 p. 6.4.5","norm_bases":["PN-EN 50182:2002 p. 6.5.2 PN-EN IEC 62641:2022-12 p. 6.4.5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Druty Wires Zdolność do nawijania Próba nawijania Ability for wrapping Wrapping test PN-EN 50182:2002 p. 6.5.2 PN-EN IEC 62641:2022-12 p. 6.4.5 Druty Wires Zdolnosc do nawijania Proba nawijania Ability for wrapping Wrapping test PN-EN 50182:2002 p. 6.5.2 PN-EN IEC 62641:2022-12 p. 6.4.5","categories":["other"],"row_index":228,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wires Ability for wrapping Wrapping test Ability for wrapping Wrapping test PN-EN 50182:2002 p. 6.5.2 PN-EN IEC 62641:2022-12 p. 6.4.5","search_zh":"钢丝 Wires PN-EN 50182:2002 p. 6.5.2 PN-EN IEC 62641:2022-12 p. 6.4.5","test_object_zh":"钢丝 Wires"},{"_id":"6a5a55ef9af9f73f38250b81","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Rury i kształtki oraz inne wyroby z tworzyw sztucznych Plastic piping systems and components","test_object_en":"Plastic piping systems and components","methodology":"Wymiary geometryczne: - grubość ścianek: rury (0 – 100) mm inne wyroby (0 – 400) mm - średnica zewnętrzna do 1200 mm - średnica wewnętrzna do 1000 mm - wymiary otworów (3 – 400) mm - odchylenie od okrągłości - długość - kąty kształtek Determination of dimensions: - wall thickness: pipes (0 – 100) mm other components (0 – 400) mm - outer diameter up to 1200 mm - inner diameter up to 1000 mm - holes’ dimensions (3 – 400) mm - roundness deviation - length - components’ angles","methodology_en":"Determination of dimensions: - wall thickness: pipes (0 – 100) mm other components (0 – 400) mm - outer diameter up to 1200 mm - inner diameter up to 1000 mm - holes’ dimensions (3 – 400) mm - roundness deviation - length - components’ angles","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary geometryczne: - grubość ścianek: rury (0 – 100) mm inne wyroby (0 – 400) mm - średnica zewnętrzna do 1200 mm - średnica wewnętrzna do 1000 mm - wymiary otworów (3 – 400) mm - odchylenie od okrągłości - długość - kąty kształtek Determination of dimensions: - wall thickness: pipes (0 – 100) mm other components (0 – 400) mm - outer diameter up to 1200 mm - inner diameter up to 1000 mm - holes’ dimensions (3 – 400) mm - roundness deviation - length - components’ angles","reference":"PN-EN ISO 3126:2006","norm_bases":["PN-EN ISO 3126:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury i kształtki oraz inne wyroby z tworzyw sztucznych Plastic piping systems and components Wymiary geometryczne: - grubość ścianek: rury (0 – 100) mm inne wyroby (0 – 400) mm - średnica zewnętrzna do 1200 mm - średnica wewnętrzna do 1000 mm - wymiary otworów (3 – 400) mm - odchylenie od okrągłości - długość - kąty kształtek Determination of dimensions: - wall thickness: pipes (0 – 100) mm other components (0 – 400) mm - outer diameter up to 1200 mm - inner diameter up to 1000 mm - holes’ dimensions (3 – 400) mm - roundness deviation - length - components’ angles PN-EN ISO 3126:2006 Rury i ksztaltki oraz inne wyroby z tworzyw sztucznych Plastic piping systems and components Wymiary geometryczne: - grubosc scianek: rury (0 – 100) mm inne wyroby (0 – 400) mm - srednica zewnetrzna do 1200 mm - srednica wewnetrzna do 1000 mm - wymiary otworow (3 – 400) mm - odchylenie od okraglosci - dlugosc - katy ksztaltek Determination of dimensions: - wall thickness: pipes (0 – 100) mm other components (0 – 400) mm - outer diameter up to 1200 mm - inner diameter up to 1000 mm - holes’ dimensions (3 – 400) mm - roundness deviation - length - components’ angles PN-EN ISO 3126:2006","categories":["materials"],"row_index":229,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic piping systems and components Determination of dimensions: - wall thickness: pipes (0 – 100) mm other components (0 – 400) mm - outer diameter up to 1200 mm - inner diameter up to 1000 mm - holes’ dimensions (3 – 400) mm - roundness deviation - length - components’ angles PN-EN ISO 3126:2006"},{"_id":"6a5a55ef9af9f73f38250b82","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Rury, folie i płyty z tworzyw sztucznych Plastic pipes, films and sheets","test_object_en":"Plastic pipes, films and sheets","methodology":"Skurcz wzdłużny Zmiany wymiarów liniowych Wygrzewanie Longitudinal reversion Determination of dimensional change on heating","methodology_en":"Longitudinal reversion Determination of dimensional change on heating","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skurcz wzdłużny Zmiany wymiarów liniowych Wygrzewanie Longitudinal reversion Determination of dimensional change on heating","reference":"PN-EN ISO 2505:2024-04 PN-EN ISO 11501:2005","norm_bases":["PN-EN ISO 2505:2024-04 PN-EN ISO 11501:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury, folie i płyty z tworzyw sztucznych Plastic pipes, films and sheets Skurcz wzdłużny Zmiany wymiarów liniowych Wygrzewanie Longitudinal reversion Determination of dimensional change on heating PN-EN ISO 2505:2024-04 PN-EN ISO 11501:2005 Rury, folie i plyty z tworzyw sztucznych Plastic pipes, films and sheets Skurcz wzdluzny Zmiany wymiarow liniowych Wygrzewanie Longitudinal reversion Determination of dimensional change on heating PN-EN ISO 2505:2024-04 PN-EN ISO 11501:2005","categories":["materials"],"row_index":230,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic pipes, films and sheets Longitudinal reversion Determination of dimensional change on heating PN-EN ISO 2505:2024-04 PN-EN ISO 11501:2005"},{"_id":"6a5a55ef9af9f73f38250b83","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Rury i kształtki rurowe i inne wyroby z tworzyw sztucznych (kształtki ruro- we o średnicy mniejszej od Ø 400 mm, inne wyroby bez ograniczeń) Plastic pipes, pipe fittings and other plastic products (pipe fittings of diameter smaller than Ø 400 mm, other products without restrictions)","test_object_en":"Plastic pipes, pipe fittings and other plastic products (pipe fittings of diameter smaller than Ø 400 mm, other products without restrictions)","methodology":"Zmiana wyglądu zewnętrznego w wyniku ogrzewania Methods for visually assessing the effects of heating","methodology_en":"Methods for visually assessing the effects of heating","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zmiana wyglądu zewnętrznego w wyniku ogrzewania Methods for visually assessing the effects of heating","reference":"PN-EN ISO 580:2006 PN-ISO 12091:2009","norm_bases":["PN-EN ISO 580:2006 PN-ISO 12091:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury i kształtki rurowe i inne wyroby z tworzyw sztucznych (kształtki ruro- we o średnicy mniejszej od Ø 400 mm, inne wyroby bez ograniczeń) Plastic pipes, pipe fittings and other plastic products (pipe fittings of diameter smaller than Ø 400 mm, other products without restrictions) Zmiana wyglądu zewnętrznego w wyniku ogrzewania Methods for visually assessing the effects of heating PN-EN ISO 580:2006 PN-ISO 12091:2009 Rury i ksztaltki rurowe i inne wyroby z tworzyw sztucznych (ksztaltki ruro- we o srednicy mniejszej od Ø 400 mm, inne wyroby bez ograniczen) Plastic pipes, pipe fittings and other plastic products (pipe fittings of diameter smaller than Ø 400 mm, other products without restrictions) Zmiana wygladu zewnetrznego w wyniku ogrzewania Methods for visually assessing the effects of heating PN-EN ISO 580:2006 PN-ISO 12091:2009","categories":["materials"],"row_index":231,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic pipes, pipe fittings and other plastic products (pipe fittings of diameter smaller than Ø 400 mm, other products without restrictions) Methods for visually assessing the effects of heating PN-EN ISO 580:2006 PN-ISO 12091:2009"},{"_id":"6a5a55ef9af9f73f38250b84","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Tworzywa sztuczne Plastics","test_object_en":"Plastics","methodology":"Absorpcja wody Metoda wagowa Determination of water absorption Weight method","methodology_en":"Water absorption Gravimetric method Determination of water absorption Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Absorpcja wody Metoda wagowa Determination of water absorption Weight method","reference":"PN-EN ISO 62:2008","norm_bases":["PN-EN ISO 62:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tworzywa sztuczne Plastics Absorpcja wody Metoda wagowa Determination of water absorption Weight method PN-EN ISO 62:2008 Tworzywa sztuczne Plastics Absorpcja wody Metoda wagowa Determination of water absorption Weight method PN-EN ISO 62:2008","categories":["water","materials"],"row_index":232,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastics Water absorption Gravimetric method Determination of water absorption Weight method PN-EN ISO 62:2008","search_zh":"塑料 Plastics PN-EN ISO 62:2008","test_object_zh":"塑料 Plastics"},{"_id":"6a5a55ef9af9f73f38250b85","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Rury z nieplastyfikowanego poli(chlorku winylu) Unplasticized poly(vinyl chloride) (PVC-U) pipes","test_object_en":"Unplasticized poly(vinyl chloride) (PVC-U) pipes","methodology":"Odporność na dichlorometan Dichloromethane resistance at specified temperature (DCMT)","methodology_en":"Dichloromethane resistance at specified temperature (DCMT)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na dichlorometan Dichloromethane resistance at specified temperature (DCMT)","reference":"PN-EN ISO 9852:2017-11","norm_bases":["PN-EN ISO 9852:2017-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury z nieplastyfikowanego poli(chlorku winylu) Unplasticized poly(vinyl chloride) (PVC-U) pipes Odporność na dichlorometan Dichloromethane resistance at specified temperature (DCMT) PN-EN ISO 9852:2017-11 Rury z nieplastyfikowanego poli(chlorku winylu) Unplasticized poly(vinyl chloride) (PVC-U) pipes Odpornosc na dichlorometan Dichloromethane resistance at specified temperature (DCMT) PN-EN ISO 9852:2017-11","categories":["other"],"row_index":233,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Unplasticized poly(vinyl chloride) (PVC-U) pipes Dichloromethane resistance at specified temperature (DCMT) PN-EN ISO 9852:2017-11"},{"_id":"6a5a55ef9af9f73f38250b86","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Tworzywa termoplastyczne Thermoplastics","test_object_en":"Thermoplastics","methodology":"Temperatura mięknienia (VST) Zakres: (50 – 250) ºC Metoda Vicata Vicat softening temperature (VST) Temperature range: (50 – 250) ºC","methodology_en":"Vicat softening temperature (VST) Temperature range: (50 – 250) ºC","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Temperatura mięknienia (VST) Zakres: (50 – 250) ºC Metoda Vicata Vicat softening temperature (VST) Temperature range: (50 – 250) ºC","reference":"PN-EN 727:1998 PN-EN ISO 2507-1:2017-11 PN-EN ISO 2507-2:2017-12 PN-EN ISO 2507-3:2017-12 PN-EN ISO 306:2023-05","norm_bases":["PN-EN 727:1998 PN-EN ISO 2507-1:2017-11 PN-EN ISO 2507-2:2017-12 PN-EN ISO 2507-3:2017-12 PN-EN ISO 306:2023-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tworzywa termoplastyczne Thermoplastics Temperatura mięknienia (VST) Zakres: (50 – 250) ºC Metoda Vicata Vicat softening temperature (VST) Temperature range: (50 – 250) ºC PN-EN 727:1998 PN-EN ISO 2507-1:2017-11 PN-EN ISO 2507-2:2017-12 PN-EN ISO 2507-3:2017-12 PN-EN ISO 306:2023-05 Tworzywa termoplastyczne Thermoplastics Temperatura mieknienia (VST) Zakres: (50 – 250) ºC Metoda Vicata Vicat softening temperature (VST) Temperature range: (50 – 250) ºC PN-EN 727:1998 PN-EN ISO 2507-1:2017-11 PN-EN ISO 2507-2:2017-12 PN-EN ISO 2507-3:2017-12 PN-EN ISO 306:2023-05","categories":["materials"],"row_index":234,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermoplastics Vicat softening temperature (VST) Temperature range: (50 – 250) ºC PN-EN 727:1998 PN-EN ISO 2507-1:2017-11 PN-EN ISO 2507-2:2017-12 PN-EN ISO 2507-3:2017-12 PN-EN ISO 306:2023-05","search_zh":"热塑性塑料 Thermoplastics PN-EN 727:1998 PN-EN ISO 2507-1:2017-11 PN-EN ISO 2507-2:2017-12 PN-EN ISO 2507-3:2017-12 PN-EN ISO 306:2023-05","test_object_zh":"热塑性塑料 Thermoplastics"},{"_id":"6a5a55ef9af9f73f38250b87","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Tworzywa termoplastyczne i termoutwardzalne Thermoplastics and thermosets","test_object_en":"Thermoplastics and thermosets","methodology":"Temperatura ugięcia pod obciążeniem (HDT) Zakres: (50 – 250) ºC Nagrzewanie ze stałą szybkością Determination of temperature of deflection under load (HDT) Temperature range: (50 – 250) ºC Heating at a constant rate","methodology_en":"Determination of temperature of deflection under load (HDT) Temperature range: (50 – 250) ºC Heating at a constant rate","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Temperatura ugięcia pod obciążeniem (HDT) Zakres: (50 – 250) ºC Nagrzewanie ze stałą szybkością Determination of temperature of deflection under load (HDT) Temperature range: (50 – 250) ºC Heating at a constant rate","reference":"PN-EN ISO 75-1:2020-09 PN-EN ISO 75-2:2013-06 PN-EN ISO 75-3:2005","norm_bases":["PN-EN ISO 75-1:2020-09 PN-EN ISO 75-2:2013-06 PN-EN ISO 75-3:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tworzywa termoplastyczne i termoutwardzalne Thermoplastics and thermosets Temperatura ugięcia pod obciążeniem (HDT) Zakres: (50 – 250) ºC Nagrzewanie ze stałą szybkością Determination of temperature of deflection under load (HDT) Temperature range: (50 – 250) ºC Heating at a constant rate PN-EN ISO 75-1:2020-09 PN-EN ISO 75-2:2013-06 PN-EN ISO 75-3:2005 Tworzywa termoplastyczne i termoutwardzalne Thermoplastics and thermosets Temperatura ugiecia pod obciazeniem (HDT) Zakres: (50 – 250) ºC Nagrzewanie ze stala szybkoscia Determination of temperature of deflection under load (HDT) Temperature range: (50 – 250) ºC Heating at a constant rate PN-EN ISO 75-1:2020-09 PN-EN ISO 75-2:2013-06 PN-EN ISO 75-3:2005","categories":["materials"],"row_index":235,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermoplastics and thermosets Determination of temperature of deflection under load (HDT) Temperature range: (50 – 250) ºC Heating at a constant rate PN-EN ISO 75-1:2020-09 PN-EN ISO 75-2:2013-06 PN-EN ISO 75-3:2005"},{"_id":"6a5a55ef9af9f73f38250b88","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Taśmy przenośnikowe i inne materiały warstwowe (materiały o grubości do 40 mm) Textile conveyor belts and other laminates (materials of thickness up to 40 mm)","test_object_en":"Textile conveyor belts and other laminates (materials of thickness up to 40 mm)","methodology":"Wytrzymałość na rozciąganie Maksymalne obciążenie 300 kN Próba rozciągania Tensile strength Maximum load 300 kN Tensile test","methodology_en":"Tensile strength Maximum load 300 kN Tensile test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na rozciąganie Maksymalne obciążenie 300 kN Próba rozciągania Tensile strength Maximum load 300 kN Tensile test","reference":"PN-EN ISO 283:2023-10","norm_bases":["PN-EN ISO 283:2023-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Taśmy przenośnikowe i inne materiały warstwowe (materiały o grubości do 40 mm) Textile conveyor belts and other laminates (materials of thickness up to 40 mm) Wytrzymałość na rozciąganie Maksymalne obciążenie 300 kN Próba rozciągania Tensile strength Maximum load 300 kN Tensile test PN-EN ISO 283:2023-10 Tasmy przenosnikowe i inne materialy warstwowe (materialy o grubosci do 40 mm) Textile conveyor belts and other laminates (materials of thickness up to 40 mm) Wytrzymalosc na rozciaganie Maksymalne obciazenie 300 kN Proba rozciagania Tensile strength Maximum load 300 kN Tensile test PN-EN ISO 283:2023-10","categories":["materials"],"row_index":236,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Textile conveyor belts and other laminates (materials of thickness up to 40 mm) Tensile strength Maximum load 300 kN Tensile test PN-EN ISO 283:2023-10","search_zh":"输送带及其他层积材料（厚度至 40 mm 的材料） Textile conveyor belts and other laminates (materials of thickness up to 40 mm) PN-EN ISO 283:2023-10","test_object_zh":"输送带及其他层积材料（厚度至 40 mm 的材料） Textile conveyor belts and other laminates (materials of thickness up to 40 mm)"},{"_id":"6a5a55ef9af9f73f38250b89","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Taśmy przenośnikowe i inne materiały warstwowe (materiały o grubości do 40 mm) Textile conveyor belts and other laminates (materials of thickness up to 40 mm)","test_object_en":"Textile conveyor belts and other laminates (materials of thickness up to 40 mm)","methodology":"Wydłużenie względne w chwili zerwania Zakres: do 500 % Próba rozciągania Elongation at break Range: up to 500% Tensile test","methodology_en":"Elongation at break Range: up to 500% Tensile test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wydłużenie względne w chwili zerwania Zakres: do 500 % Próba rozciągania Elongation at break Range: up to 500% Tensile test","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Taśmy przenośnikowe i inne materiały warstwowe (materiały o grubości do 40 mm) Textile conveyor belts and other laminates (materials of thickness up to 40 mm) Wydłużenie względne w chwili zerwania Zakres: do 500 % Próba rozciągania Elongation at break Range: up to 500% Tensile test Tasmy przenosnikowe i inne materialy warstwowe (materialy o grubosci do 40 mm) Textile conveyor belts and other laminates (materials of thickness up to 40 mm) Wydluzenie wzgledne w chwili zerwania Zakres: do 500 % Proba rozciagania Elongation at break Range: up to 500% Tensile test","categories":["materials"],"row_index":237,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Textile conveyor belts and other laminates (materials of thickness up to 40 mm) Elongation at break Range: up to 500% Tensile test","search_zh":"输送带及其他层积材料（厚度至 40 mm 的材料） Textile conveyor belts and other laminates (materials of thickness up to 40 mm)","test_object_zh":"输送带及其他层积材料（厚度至 40 mm 的材料） Textile conveyor belts and other laminates (materials of thickness up to 40 mm)"},{"_id":"6a5a55ef9af9f73f38250b8a","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Taśmy przenośnikowe i inne materiały warstwowe (materiały o grubości do 40 mm) Textile conveyor belts and other laminates (materials of thickness up to 40 mm)","test_object_en":"Textile conveyor belts and other laminates (materials of thickness up to 40 mm)","methodology":"Wydłużenie względne przy obciążeniu równym 10 % wytrzymałości nominalnej Zakres: do 100 % Próba rozciągania Elongation at the reference force (load) Range up to 100% Tensile test","methodology_en":"Elongation at the reference force (load) equal to 10 % of the nominal strength Range up to 100% Tensile test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wydłużenie względne przy obciążeniu równym 10 % wytrzymałości nominalnej Zakres: do 100 % Próba rozciągania Elongation at the reference force (load) Range up to 100% Tensile test","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Taśmy przenośnikowe i inne materiały warstwowe (materiały o grubości do 40 mm) Textile conveyor belts and other laminates (materials of thickness up to 40 mm) Wydłużenie względne przy obciążeniu równym 10 % wytrzymałości nominalnej Zakres: do 100 % Próba rozciągania Elongation at the reference force (load) Range up to 100% Tensile test Tasmy przenosnikowe i inne materialy warstwowe (materialy o grubosci do 40 mm) Textile conveyor belts and other laminates (materials of thickness up to 40 mm) Wydluzenie wzgledne przy obciazeniu rownym 10 % wytrzymalosci nominalnej Zakres: do 100 % Proba rozciagania Elongation at the reference force (load) Range up to 100% Tensile test","categories":["materials"],"row_index":238,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Textile conveyor belts and other laminates (materials of thickness up to 40 mm) Elongation at the reference force (load) equal to 10 % of the nominal strength Range up to 100% Tensile test","search_zh":"输送带及其他层积材料（厚度至 40 mm 的材料） Textile conveyor belts and other laminates (materials of thickness up to 40 mm)","test_object_zh":"输送带及其他层积材料（厚度至 40 mm 的材料） Textile conveyor belts and other laminates (materials of thickness up to 40 mm)"},{"_id":"6a5a55ef9af9f73f38250b8b","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Taśmy przenośnikowe i inne materiały warstwowe (materiały o grubości do 40 mm) Textile conveyor belts and other laminates (materials of thickness up to 40 mm)","test_object_en":"Textile conveyor belts and other laminates (materials of thickness up to 40 mm)","methodology":"Wytrzymałość adhezyjna Maksymalne obciążenie 300 kN Próba rozwarstwiania Adhesive strength Maximum load 300 kN Delamination test","methodology_en":"Adhesive strength Maximum load 300 kN Delamination test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość adhezyjna Maksymalne obciążenie 300 kN Próba rozwarstwiania Adhesive strength Maximum load 300 kN Delamination test","reference":"PN-EN ISO 252:2023-09","norm_bases":["PN-EN ISO 252:2023-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Taśmy przenośnikowe i inne materiały warstwowe (materiały o grubości do 40 mm) Textile conveyor belts and other laminates (materials of thickness up to 40 mm) Wytrzymałość adhezyjna Maksymalne obciążenie 300 kN Próba rozwarstwiania Adhesive strength Maximum load 300 kN Delamination test PN-EN ISO 252:2023-09 Tasmy przenosnikowe i inne materialy warstwowe (materialy o grubosci do 40 mm) Textile conveyor belts and other laminates (materials of thickness up to 40 mm) Wytrzymalosc adhezyjna Maksymalne obciazenie 300 kN Proba rozwarstwiania Adhesive strength Maximum load 300 kN Delamination test PN-EN ISO 252:2023-09","categories":["materials"],"row_index":239,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Textile conveyor belts and other laminates (materials of thickness up to 40 mm) Adhesive strength Maximum load 300 kN Delamination test PN-EN ISO 252:2023-09","search_zh":"输送带及其他层积材料（厚度至 40 mm 的材料） Textile conveyor belts and other laminates (materials of thickness up to 40 mm) PN-EN ISO 252:2023-09","test_object_zh":"输送带及其他层积材料（厚度至 40 mm 的材料） Textile conveyor belts and other laminates (materials of thickness up to 40 mm)"},{"_id":"6a5a55ef9af9f73f38250b8c","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Wyroby z tworzyw termoplastycznych Thermoplastics products","test_object_en":"Thermoplastics products","methodology":"Kąt zgięcia wyrobów z połączeniami spawanymi lub zgrzewanymi Zakres: do 160 º Próba zginania The bending angle of products with welded joints Range up to 160 º Bending test","methodology_en":"The bending angle of products with welded joints Range up to 160 º Bending test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Kąt zgięcia wyrobów z połączeniami spawanymi lub zgrzewanymi Zakres: do 160 º Próba zginania The bending angle of products with welded joints Range up to 160 º Bending test","reference":"PN-EN 12814-1:2002+AC:2004 PN-EN 12814-8:2021-07","norm_bases":["PN-EN 12814-1:2002+AC:2004 PN-EN 12814-8:2021-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw termoplastycznych Thermoplastics products Kąt zgięcia wyrobów z połączeniami spawanymi lub zgrzewanymi Zakres: do 160 º Próba zginania The bending angle of products with welded joints Range up to 160 º Bending test PN-EN 12814-1:2002+AC:2004 PN-EN 12814-8:2021-07 Wyroby z tworzyw termoplastycznych Thermoplastics products Kat zgiecia wyrobow z polaczeniami spawanymi lub zgrzewanymi Zakres: do 160 º Proba zginania The bending angle of products with welded joints Range up to 160 º Bending test PN-EN 12814-1:2002+AC:2004 PN-EN 12814-8:2021-07","categories":["materials"],"row_index":240,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermoplastics products The bending angle of products with welded joints Range up to 160 º Bending test PN-EN 12814-1:2002+AC:2004 PN-EN 12814-8:2021-07"},{"_id":"6a5a55ef9af9f73f38250b8d","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Wyroby z tworzyw termoplastycznych Thermoplastics products","test_object_en":"Thermoplastics products","methodology":"Wytrzymałość na rozciąganie wyrobów z połączeniami spawanymi lub zgrzewanymi Maksymalne obciążenie 300 kN Próba rozciągania Tensile strength of products with welded joints Maximum load 300 kN Tensile test","methodology_en":"Tensile strength of products with fusion-welded or resistance-welded joints Maximum load 300 kN Tensile test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na rozciąganie wyrobów z połączeniami spawanymi lub zgrzewanymi Maksymalne obciążenie 300 kN Próba rozciągania Tensile strength of products with welded joints Maximum load 300 kN Tensile test","reference":"PN-EN 12814-2:2021-06 PN-EN 12814-8:2021-07","norm_bases":["PN-EN 12814-2:2021-06 PN-EN 12814-8:2021-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw termoplastycznych Thermoplastics products Wytrzymałość na rozciąganie wyrobów z połączeniami spawanymi lub zgrzewanymi Maksymalne obciążenie 300 kN Próba rozciągania Tensile strength of products with welded joints Maximum load 300 kN Tensile test PN-EN 12814-2:2021-06 PN-EN 12814-8:2021-07 Wyroby z tworzyw termoplastycznych Thermoplastics products Wytrzymalosc na rozciaganie wyrobow z polaczeniami spawanymi lub zgrzewanymi Maksymalne obciazenie 300 kN Proba rozciagania Tensile strength of products with welded joints Maximum load 300 kN Tensile test PN-EN 12814-2:2021-06 PN-EN 12814-8:2021-07","categories":["materials"],"row_index":241,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermoplastics products Tensile strength of products with fusion-welded or resistance-welded joints Maximum load 300 kN Tensile test PN-EN 12814-2:2021-06 PN-EN 12814-8:2021-07"},{"_id":"6a5a55ef9af9f73f38250b8e","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Tworzywa sztuczne, kompozyty polimerowe, guma, kauczuk, rury z tworzyw sztucznych Plastics, polymer composites, rubber (vulcanized or thermoplastic), plastic pipes","test_object_en":"Plastics, polymer composites, rubber (vulcanized or thermoplastic), plastic pipes","methodology":"Wytrzymałość na rozciąganie i wydłużenie względne przy zerwaniu Maksymalne obciążenie 300 kN wydłużenie do 800 % Próba rozciągania Tensile strength and strain at break Maximum load 300 kN, elongation up to 800% Tensile test","methodology_en":"Tensile strength and strain at break Maximum load 300 kN, elongation up to 800% Tensile test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na rozciąganie i wydłużenie względne przy zerwaniu Maksymalne obciążenie 300 kN wydłużenie do 800 % Próba rozciągania Tensile strength and strain at break Maximum load 300 kN, elongation up to 800% Tensile test","reference":"PN-EN ISO 527-1:2020-01 PN-EN ISO 527-2:2012 PN-EN ISO 527-3:2019-01 PN-EN ISO 527-4:2023-10 PN-EN ISO 527-5:2022-06 PN-ISO 37:2007+AC1:2008 PN-EN ISO 6259-1:2015-05 PN-EN ISO 6259-3:2015-08","norm_bases":["PN-EN ISO 527-1:2020-01 PN-EN ISO 527-2:2012 PN-EN ISO 527-3:2019-01 PN-EN ISO 527-4:2023-10 PN-EN ISO 527-5:2022-06 PN-ISO 37:2007+AC1:2008 PN-EN ISO 6259-1:2015-05 PN-EN ISO 6259-3:2015-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tworzywa sztuczne, kompozyty polimerowe, guma, kauczuk, rury z tworzyw sztucznych Plastics, polymer composites, rubber (vulcanized or thermoplastic), plastic pipes Wytrzymałość na rozciąganie i wydłużenie względne przy zerwaniu Maksymalne obciążenie 300 kN wydłużenie do 800 % Próba rozciągania Tensile strength and strain at break Maximum load 300 kN, elongation up to 800% Tensile test PN-EN ISO 527-1:2020-01 PN-EN ISO 527-2:2012 PN-EN ISO 527-3:2019-01 PN-EN ISO 527-4:2023-10 PN-EN ISO 527-5:2022-06 PN-ISO 37:2007+AC1:2008 PN-EN ISO 6259-1:2015-05 PN-EN ISO 6259-3:2015-08 Tworzywa sztuczne, kompozyty polimerowe, guma, kauczuk, rury z tworzyw sztucznych Plastics, polymer composites, rubber (vulcanized or thermoplastic), plastic pipes Wytrzymalosc na rozciaganie i wydluzenie wzgledne przy zerwaniu Maksymalne obciazenie 300 kN wydluzenie do 800 % Proba rozciagania Tensile strength and strain at break Maximum load 300 kN, elongation up to 800% Tensile test PN-EN ISO 527-1:2020-01 PN-EN ISO 527-2:2012 PN-EN ISO 527-3:2019-01 PN-EN ISO 527-4:2023-10 PN-EN ISO 527-5:2022-06 PN-ISO 37:2007+AC1:2008 PN-EN ISO 6259-1:2015-05 PN-EN ISO 6259-3:2015-08","categories":["materials"],"row_index":242,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastics, polymer composites, rubber (vulcanized or thermoplastic), plastic pipes Tensile strength and strain at break Maximum load 300 kN, elongation up to 800% Tensile test PN-EN ISO 527-1:2020-01 PN-EN ISO 527-2:2012 PN-EN ISO 527-3:2019-01 PN-EN ISO 527-4:2023-10 PN-EN ISO 527-5:2022-06 PN-ISO 37:2007+AC1:2008 PN-EN ISO 6259-1:2015-05 PN-EN ISO 6259-3:2015-08"},{"_id":"6a5a55ef9af9f73f38250b8f","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Tworzywa sztuczne, kompozyty polimerowe, guma, kauczuk, rury z tworzyw sztucznych Plastics, polymer composites, rubber (vulcanized or thermoplastic), plastic pipes","test_object_en":"Plastics, polymer composites, rubber (vulcanized or thermoplastic), plastic pipes","methodology":"Moduł sprężystości przy rozciąganiu Maksymalne obciążenie 300 kN Próba rozciągania Modulus of elasticity under tension Maximum load 300 kN Tensile test","methodology_en":"Modulus of elasticity under tension Maximum load 300 kN Tensile test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moduł sprężystości przy rozciąganiu Maksymalne obciążenie 300 kN Próba rozciągania Modulus of elasticity under tension Maximum load 300 kN Tensile test","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tworzywa sztuczne, kompozyty polimerowe, guma, kauczuk, rury z tworzyw sztucznych Plastics, polymer composites, rubber (vulcanized or thermoplastic), plastic pipes Moduł sprężystości przy rozciąganiu Maksymalne obciążenie 300 kN Próba rozciągania Modulus of elasticity under tension Maximum load 300 kN Tensile test Tworzywa sztuczne, kompozyty polimerowe, guma, kauczuk, rury z tworzyw sztucznych Plastics, polymer composites, rubber (vulcanized or thermoplastic), plastic pipes Modul sprezystosci przy rozciaganiu Maksymalne obciazenie 300 kN Proba rozciagania Modulus of elasticity under tension Maximum load 300 kN Tensile test","categories":["materials"],"row_index":243,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastics, polymer composites, rubber (vulcanized or thermoplastic), plastic pipes Modulus of elasticity under tension Maximum load 300 kN Tensile test"},{"_id":"6a5a55ef9af9f73f38250b90","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Tworzywa sztuczne, kompozyty polimerowe Plastics, polymer composites","test_object_en":"Plastics, polymer composites","methodology":"Wytrzymałość na zginanie Maksymalne obciążenie 300 kN Próba zginania Flexural strength Maximum load 300 kN Bending test","methodology_en":"Flexural strength Maximum load 300 kN Bending test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na zginanie Maksymalne obciążenie 300 kN Próba zginania Flexural strength Maximum load 300 kN Bending test","reference":"PN-EN ISO 178:2019-06 PN-EN ISO 14125:2001+AC:2003+ A1:2011","norm_bases":["PN-EN ISO 178:2019-06 PN-EN ISO 14125:2001+AC:2003+ A1:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tworzywa sztuczne, kompozyty polimerowe Plastics, polymer composites Wytrzymałość na zginanie Maksymalne obciążenie 300 kN Próba zginania Flexural strength Maximum load 300 kN Bending test PN-EN ISO 178:2019-06 PN-EN ISO 14125:2001+AC:2003+ A1:2011 Tworzywa sztuczne, kompozyty polimerowe Plastics, polymer composites Wytrzymalosc na zginanie Maksymalne obciazenie 300 kN Proba zginania Flexural strength Maximum load 300 kN Bending test PN-EN ISO 178:2019-06 PN-EN ISO 14125:2001+AC:2003+ A1:2011","categories":["materials"],"row_index":244,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastics, polymer composites Flexural strength Maximum load 300 kN Bending test PN-EN ISO 178:2019-06 PN-EN ISO 14125:2001+AC:2003+ A1:2011","search_zh":"塑料、聚合物复合材料 Plastics, polymer composites PN-EN ISO 178:2019-06 PN-EN ISO 14125:2001+AC:2003+ A1:2011","test_object_zh":"塑料、聚合物复合材料 Plastics, polymer composites"},{"_id":"6a5a55ef9af9f73f38250b91","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Tworzywa sztuczne, kompozyty polimerowe Plastics, polymer composites","test_object_en":"Plastics, polymer composites","methodology":"Moduł sprężystości przy zginaniu Maksymalne obciążenie 300 kN Próba zginania Modulus of elasticity in flexure Maximum load 300 kN Bending test","methodology_en":"Modulus of elasticity in flexure Maximum load 300 kN Bending test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moduł sprężystości przy zginaniu Maksymalne obciążenie 300 kN Próba zginania Modulus of elasticity in flexure Maximum load 300 kN Bending test","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tworzywa sztuczne, kompozyty polimerowe Plastics, polymer composites Moduł sprężystości przy zginaniu Maksymalne obciążenie 300 kN Próba zginania Modulus of elasticity in flexure Maximum load 300 kN Bending test Tworzywa sztuczne, kompozyty polimerowe Plastics, polymer composites Modul sprezystosci przy zginaniu Maksymalne obciazenie 300 kN Proba zginania Modulus of elasticity in flexure Maximum load 300 kN Bending test","categories":["materials"],"row_index":245,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastics, polymer composites Modulus of elasticity in flexure Maximum load 300 kN Bending test","search_zh":"塑料、聚合物复合材料 Plastics, polymer composites","test_object_zh":"塑料、聚合物复合材料 Plastics, polymer composites"},{"_id":"6a5a55ef9af9f73f38250b92","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Tworzywa sztuczne, kompozyty polimerowe, guma, kauczuk Plastics, polymer composites, rubber","test_object_en":"Plastics, polymer composites, rubber, caoutchouc","methodology":"Wytrzymałość na ściskanie Maksymalne obciążenie 300 kN Próba ściskania Compressive strength Maximum load 300 kN Compression test","methodology_en":"Compressive strength Maximum load 300 kN Compression test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie Maksymalne obciążenie 300 kN Próba ściskania Compressive strength Maximum load 300 kN Compression test","reference":"PN-EN ISO 3386-1:2000+A1:2010 PN-EN ISO 3386-2:2001+A1:2010 PN-ISO 5893:2015-12 PN-EN 12390-3:2019-07 PN-93/C-89071 PN-EN ISO 604:2006","norm_bases":["PN-EN ISO 3386-1:2000+A1:2010 PN-EN ISO 3386-2:2001+A1:2010 PN-ISO 5893:2015-12 PN-EN 12390-3:2019-07 PN-93/C-89071 PN-EN ISO 604:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tworzywa sztuczne, kompozyty polimerowe, guma, kauczuk Plastics, polymer composites, rubber Wytrzymałość na ściskanie Maksymalne obciążenie 300 kN Próba ściskania Compressive strength Maximum load 300 kN Compression test PN-EN ISO 3386-1:2000+A1:2010 PN-EN ISO 3386-2:2001+A1:2010 PN-ISO 5893:2015-12 PN-EN 12390-3:2019-07 PN-93/C-89071 PN-EN ISO 604:2006 Tworzywa sztuczne, kompozyty polimerowe, guma, kauczuk Plastics, polymer composites, rubber Wytrzymalosc na sciskanie Maksymalne obciazenie 300 kN Proba sciskania Compressive strength Maximum load 300 kN Compression test PN-EN ISO 3386-1:2000+A1:2010 PN-EN ISO 3386-2:2001+A1:2010 PN-ISO 5893:2015-12 PN-EN 12390-3:2019-07 PN-93/C-89071 PN-EN ISO 604:2006","categories":["materials"],"row_index":246,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastics, polymer composites, rubber, caoutchouc Compressive strength Maximum load 300 kN Compression test PN-EN ISO 3386-1:2000+A1:2010 PN-EN ISO 3386-2:2001+A1:2010 PN-ISO 5893:2015-12 PN-EN 12390-3:2019-07 PN-93/C-89071 PN-EN ISO 604:2006"},{"_id":"6a5a55ef9af9f73f38250b93","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Rury z tworzyw sztucznych (rury o średnicy zewnętrznej do Ø = 630 mm) Plastic pipes (pipes of outer diameter up to Ø = 630 mm)","test_object_en":"Plastic pipes (pipes of outer diameter up to Ø = 630 mm)","methodology":"Odporność na uderzenia zewnętrzne Metoda spadającego ciężarka Masa ciężarka do 8 kg Wysokość spadania do 3 m Resistance to external blows Round-the-clock method Weight of the weight up to 8 kg Drop height up to 3 m","methodology_en":"Resistance to external blows Falling weight method Weight of the weight up to 8 kg Drop height up to 3 m","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenia zewnętrzne Metoda spadającego ciężarka Masa ciężarka do 8 kg Wysokość spadania do 3 m Resistance to external blows Round-the-clock method Weight of the weight up to 8 kg Drop height up to 3 m","reference":"PN-EN 744:1997 PN-EN ISO 3127:2017-12","norm_bases":["PN-EN 744:1997 PN-EN ISO 3127:2017-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury z tworzyw sztucznych (rury o średnicy zewnętrznej do Ø = 630 mm) Plastic pipes (pipes of outer diameter up to Ø = 630 mm) Odporność na uderzenia zewnętrzne Metoda spadającego ciężarka Masa ciężarka do 8 kg Wysokość spadania do 3 m Resistance to external blows Round-the-clock method Weight of the weight up to 8 kg Drop height up to 3 m PN-EN 744:1997 PN-EN ISO 3127:2017-12 Rury z tworzyw sztucznych (rury o srednicy zewnetrznej do Ø = 630 mm) Plastic pipes (pipes of outer diameter up to Ø = 630 mm) Odpornosc na uderzenia zewnetrzne Metoda spadajacego ciezarka Masa ciezarka do 8 kg Wysokosc spadania do 3 m Resistance to external blows Round-the-clock method Weight of the weight up to 8 kg Drop height up to 3 m PN-EN 744:1997 PN-EN ISO 3127:2017-12","categories":["materials"],"row_index":247,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic pipes (pipes of outer diameter up to Ø = 630 mm) Resistance to external blows Falling weight method Weight of the weight up to 8 kg Drop height up to 3 m PN-EN 744:1997 PN-EN ISO 3127:2017-12"},{"_id":"6a5a55ef9af9f73f38250b94","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Rury z tworzyw sztucznych (rury o średnicy zewnętrznej do Ø = 630 mm) Plastic pipes (pipes of outer diameter up to Ø = 630 mm)","test_object_en":"Plastic pipes (pipes of outer diameter up to Ø = 630 mm)","methodology":"Odporność na uderzenia zewnętrzne Metoda schodkowa Masa ciężarka do 8 kg Wysokość spadania do 3 m Resistance to external blows Staircase method Weight of the weight up to 8 kg Drop height up to 3 m","methodology_en":"Resistance to external blows Staircase method Weight of the weight up to 8 kg Drop height up to 3 m","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenia zewnętrzne Metoda schodkowa Masa ciężarka do 8 kg Wysokość spadania do 3 m Resistance to external blows Staircase method Weight of the weight up to 8 kg Drop height up to 3 m","reference":"PN-EN ISO 11173:2017-12","norm_bases":["PN-EN ISO 11173:2017-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury z tworzyw sztucznych (rury o średnicy zewnętrznej do Ø = 630 mm) Plastic pipes (pipes of outer diameter up to Ø = 630 mm) Odporność na uderzenia zewnętrzne Metoda schodkowa Masa ciężarka do 8 kg Wysokość spadania do 3 m Resistance to external blows Staircase method Weight of the weight up to 8 kg Drop height up to 3 m PN-EN ISO 11173:2017-12 Rury z tworzyw sztucznych (rury o srednicy zewnetrznej do Ø = 630 mm) Plastic pipes (pipes of outer diameter up to Ø = 630 mm) Odpornosc na uderzenia zewnetrzne Metoda schodkowa Masa ciezarka do 8 kg Wysokosc spadania do 3 m Resistance to external blows Staircase method Weight of the weight up to 8 kg Drop height up to 3 m PN-EN ISO 11173:2017-12","categories":["materials"],"row_index":248,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic pipes (pipes of outer diameter up to Ø = 630 mm) Resistance to external blows Staircase method Weight of the weight up to 8 kg Drop height up to 3 m PN-EN ISO 11173:2017-12"},{"_id":"6a5a55ef9af9f73f38250b95","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Rury i kształtki z tworzyw sztucznych (rury o średnicy zewnętrznej do Ø 950 mm) Plastic pipes and pipe fittings (pipes of outer diameter up to Ø 950 mm)","test_object_en":"Plastic pipes and pipe fittings (pipes of outer diameter up to Ø 950 mm)","methodology":"Sztywność obwodowa Maksymalne obciążenie 300 kN Próba ściskania Ring stiffness Maximum load 300 kN Compression test","methodology_en":"Ring stiffness Maximum load 300 kN Compression test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sztywność obwodowa Maksymalne obciążenie 300 kN Próba ściskania Ring stiffness Maximum load 300 kN Compression test","reference":"PN-EN ISO 9969:2016-02 PN-EN 1228:1999 PN-EN ISO 13967:2011","norm_bases":["PN-EN ISO 9969:2016-02 PN-EN 1228:1999 PN-EN ISO 13967:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury i kształtki z tworzyw sztucznych (rury o średnicy zewnętrznej do Ø 950 mm) Plastic pipes and pipe fittings (pipes of outer diameter up to Ø 950 mm) Sztywność obwodowa Maksymalne obciążenie 300 kN Próba ściskania Ring stiffness Maximum load 300 kN Compression test PN-EN ISO 9969:2016-02 PN-EN 1228:1999 PN-EN ISO 13967:2011 Rury i ksztaltki z tworzyw sztucznych (rury o srednicy zewnetrznej do Ø 950 mm) Plastic pipes and pipe fittings (pipes of outer diameter up to Ø 950 mm) Sztywnosc obwodowa Maksymalne obciazenie 300 kN Proba sciskania Ring stiffness Maximum load 300 kN Compression test PN-EN ISO 9969:2016-02 PN-EN 1228:1999 PN-EN ISO 13967:2011","categories":["materials"],"row_index":249,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic pipes and pipe fittings (pipes of outer diameter up to Ø 950 mm) Ring stiffness Maximum load 300 kN Compression test PN-EN ISO 9969:2016-02 PN-EN 1228:1999 PN-EN ISO 13967:2011"},{"_id":"6a5a55ef9af9f73f38250b96","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Rury i kształtki z tworzyw sztucznych (rury o średnicy zewnętrznej do Ø 950 mm) Plastic pipes and pipe fittings (pipes of outer diameter up to Ø 950 mm)","test_object_en":"Plastic pipes and pipe fittings (pipes of outer diameter up to Ø 950 mm)","methodology":"Elastyczność obwodowa Maksymalne obciążenie 300 kN Próba ściskania Ring flexibility Maximum load 300 kN Compression test","methodology_en":"Ring flexibility Maximum load 300 kN Compression test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Elastyczność obwodowa Maksymalne obciążenie 300 kN Próba ściskania Ring flexibility Maximum load 300 kN Compression test","reference":"PN-EN ISO 13968:2009","norm_bases":["PN-EN ISO 13968:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury i kształtki z tworzyw sztucznych (rury o średnicy zewnętrznej do Ø 950 mm) Plastic pipes and pipe fittings (pipes of outer diameter up to Ø 950 mm) Elastyczność obwodowa Maksymalne obciążenie 300 kN Próba ściskania Ring flexibility Maximum load 300 kN Compression test PN-EN ISO 13968:2009 Rury i ksztaltki z tworzyw sztucznych (rury o srednicy zewnetrznej do Ø 950 mm) Plastic pipes and pipe fittings (pipes of outer diameter up to Ø 950 mm) Elastycznosc obwodowa Maksymalne obciazenie 300 kN Proba sciskania Ring flexibility Maximum load 300 kN Compression test PN-EN ISO 13968:2009","categories":["materials"],"row_index":250,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic pipes and pipe fittings (pipes of outer diameter up to Ø 950 mm) Ring flexibility Maximum load 300 kN Compression test PN-EN ISO 13968:2009"},{"_id":"6a5a55ef9af9f73f38250b97","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Tworzywa termoplastyczne Thermoplastics","test_object_en":"Thermoplastics","methodology":"Masowy i objętościowy wskaźnik szybkości płynięcia Zakres: (0,1 – 75) g/10 min Metoda plastometryczna Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics Range: (0,1 – 75) g/10 min Standard method","methodology_en":"Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics Range: (0,1 – 75) g/10 min Standard method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Masowy i objętościowy wskaźnik szybkości płynięcia Zakres: (0,1 – 75) g/10 min Metoda plastometryczna Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics Range: (0,1 – 75) g/10 min Standard method","reference":"PN-EN ISO 1133-1:2022-12","norm_bases":["PN-EN ISO 1133-1:2022-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tworzywa termoplastyczne Thermoplastics Masowy i objętościowy wskaźnik szybkości płynięcia Zakres: (0,1 – 75) g/10 min Metoda plastometryczna Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics Range: (0,1 – 75) g/10 min Standard method PN-EN ISO 1133-1:2022-12 Tworzywa termoplastyczne Thermoplastics Masowy i objetosciowy wskaznik szybkosci plyniecia Zakres: (0,1 – 75) g/10 min Metoda plastometryczna Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics Range: (0,1 – 75) g/10 min Standard method PN-EN ISO 1133-1:2022-12","categories":["materials"],"row_index":251,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermoplastics Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics Range: (0,1 – 75) g/10 min Standard method PN-EN ISO 1133-1:2022-12","search_zh":"热塑性塑料 Thermoplastics PN-EN ISO 1133-1:2022-12","test_object_zh":"热塑性塑料 Thermoplastics"},{"_id":"6a5a55ef9af9f73f38250b98","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Tworzywa sztuczne, kompozyty polimerowe Plastics, polymer composites","test_object_en":"Plastics, polymer composites","methodology":"Udarność Próbki bez karbu Zakres: energia udaru do 50 J Próba udarności Determination of Charpy impact properties Range: impact energy up to 50 J Impact test","methodology_en":"Determination of Charpy impact properties Range: impact energy up to 50 J Impact test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Udarność Próbki bez karbu Zakres: energia udaru do 50 J Próba udarności Determination of Charpy impact properties Range: impact energy up to 50 J Impact test","reference":"PN-EN ISO 179-1:2010 PN-EN ISO 179-1:2023-11","norm_bases":["PN-EN ISO 179-1:2010 PN-EN ISO 179-1:2023-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tworzywa sztuczne, kompozyty polimerowe Plastics, polymer composites Udarność Próbki bez karbu Zakres: energia udaru do 50 J Próba udarności Determination of Charpy impact properties Range: impact energy up to 50 J Impact test PN-EN ISO 179-1:2010 PN-EN ISO 179-1:2023-11 Tworzywa sztuczne, kompozyty polimerowe Plastics, polymer composites Udarnosc Probki bez karbu Zakres: energia udaru do 50 J Proba udarnosci Determination of Charpy impact properties Range: impact energy up to 50 J Impact test PN-EN ISO 179-1:2010 PN-EN ISO 179-1:2023-11","categories":["materials"],"row_index":252,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastics, polymer composites Determination of Charpy impact properties Range: impact energy up to 50 J Impact test PN-EN ISO 179-1:2010 PN-EN ISO 179-1:2023-11","search_zh":"塑料、聚合物复合材料 Plastics, polymer composites PN-EN ISO 179-1:2010 PN-EN ISO 179-1:2023-11","test_object_zh":"塑料、聚合物复合材料 Plastics, polymer composites"},{"_id":"6a5a55ef9af9f73f38250b99","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Tworzywa sztuczne, kompozyty polimerowe Plastics, polymer composites","test_object_en":"Plastics, polymer composites","methodology":"Wytrzymałość na udarowe rozciąganie Zakres: energia udaru do 50 J Próba udarności Tensile-impact strength Range: impact energy up to 50 J Impact test","methodology_en":"Tensile-impact strength Range: impact energy up to 50 J Impact test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na udarowe rozciąganie Zakres: energia udaru do 50 J Próba udarności Tensile-impact strength Range: impact energy up to 50 J Impact test","reference":"PN-EN ISO 8256:2024-06","norm_bases":["PN-EN ISO 8256:2024-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tworzywa sztuczne, kompozyty polimerowe Plastics, polymer composites Wytrzymałość na udarowe rozciąganie Zakres: energia udaru do 50 J Próba udarności Tensile-impact strength Range: impact energy up to 50 J Impact test PN-EN ISO 8256:2024-06 Tworzywa sztuczne, kompozyty polimerowe Plastics, polymer composites Wytrzymalosc na udarowe rozciaganie Zakres: energia udaru do 50 J Proba udarnosci Tensile-impact strength Range: impact energy up to 50 J Impact test PN-EN ISO 8256:2024-06","categories":["materials"],"row_index":253,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastics, polymer composites Tensile-impact strength Range: impact energy up to 50 J Impact test PN-EN ISO 8256:2024-06","search_zh":"塑料、聚合物复合材料 Plastics, polymer composites PN-EN ISO 8256:2024-06","test_object_zh":"塑料、聚合物复合材料 Plastics, polymer composites"},{"_id":"6a5a55ef9af9f73f38250b9a","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych o przekrojach zamkniętych Thermoplastics pipes, fittings and assemblies with closed sections","test_object_en":"Thermoplastics pipes, fittings and assemblies with closed sections","methodology":"Wytrzymałość na ciśnienie wewnętrzne Zakres: - ciśnienie max 6 MPa dla średnic do Ø 400 mm, - ciśnienie max 0,5 MPa bez ograniczeń dla średnicy Próba ciśnieniowa Resistance to internal pressure Range: - max pressure 6 MPa for diameters up to Ø 400 mm, - max pressure 0,5 MPa no restriction on diameter Pressure test","methodology_en":"Resistance to internal pressure Range: - max pressure 6 MPa for diameters up to Ø 400 mm, - max pressure 0,5 MPa no restriction on diameter Pressure test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ciśnienie wewnętrzne Zakres: - ciśnienie max 6 MPa dla średnic do Ø 400 mm, - ciśnienie max 0,5 MPa bez ograniczeń dla średnicy Próba ciśnieniowa Resistance to internal pressure Range: - max pressure 6 MPa for diameters up to Ø 400 mm, - max pressure 0,5 MPa no restriction on diameter Pressure test","reference":"PN-EN ISO 1167-1:2007 PN-EN ISO 1167-2:2007 PN-EN ISO 1167-3:2008 PN-EN ISO 1167-4:2008","norm_bases":["PN-EN ISO 1167-1:2007 PN-EN ISO 1167-2:2007 PN-EN ISO 1167-3:2008 PN-EN ISO 1167-4:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych o przekrojach zamkniętych Thermoplastics pipes, fittings and assemblies with closed sections Wytrzymałość na ciśnienie wewnętrzne Zakres: - ciśnienie max 6 MPa dla średnic do Ø 400 mm, - ciśnienie max 0,5 MPa bez ograniczeń dla średnicy Próba ciśnieniowa Resistance to internal pressure Range: - max pressure 6 MPa for diameters up to Ø 400 mm, - max pressure 0,5 MPa no restriction on diameter Pressure test PN-EN ISO 1167-1:2007 PN-EN ISO 1167-2:2007 PN-EN ISO 1167-3:2008 PN-EN ISO 1167-4:2008 Wyroby z tworzyw sztucznych o przekrojach zamknietych Thermoplastics pipes, fittings and assemblies with closed sections Wytrzymalosc na cisnienie wewnetrzne Zakres: - cisnienie max 6 MPa dla srednic do Ø 400 mm, - cisnienie max 0,5 MPa bez ograniczen dla srednicy Proba cisnieniowa Resistance to internal pressure Range: - max pressure 6 MPa for diameters up to Ø 400 mm, - max pressure 0,5 MPa no restriction on diameter Pressure test PN-EN ISO 1167-1:2007 PN-EN ISO 1167-2:2007 PN-EN ISO 1167-3:2008 PN-EN ISO 1167-4:2008","categories":["other"],"row_index":254,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thermoplastics pipes, fittings and assemblies with closed sections Resistance to internal pressure Range: - max pressure 6 MPa for diameters up to Ø 400 mm, - max pressure 0,5 MPa no restriction on diameter Pressure test PN-EN ISO 1167-1:2007 PN-EN ISO 1167-2:2007 PN-EN ISO 1167-3:2008 PN-EN ISO 1167-4:2008"},{"_id":"6a5a55ef9af9f73f38250b9b","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Rury z tworzyw sztucznych (Ø 160 mm – 800mm) Plastic pipes (Ø 160 mm – 800mm)","test_object_en":"Plastic pipes (Ø 160 mm – 800mm)","methodology":"Wskaźnik pełzania Zakres: wielkość odkształcenia do 50 mm Próba pełzania Creep ratio Range: amount of deformation make 50 mm Creep test","methodology_en":"Creep ratio Range: amount of deformation make 50 mm Creep test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik pełzania Zakres: wielkość odkształcenia do 50 mm Próba pełzania Creep ratio Range: amount of deformation make 50 mm Creep test","reference":"PN-EN ISO 9967:2016-02 PN-EN 761:2001","norm_bases":["PN-EN ISO 9967:2016-02 PN-EN 761:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury z tworzyw sztucznych (Ø 160 mm – 800mm) Plastic pipes (Ø 160 mm – 800mm) Wskaźnik pełzania Zakres: wielkość odkształcenia do 50 mm Próba pełzania Creep ratio Range: amount of deformation make 50 mm Creep test PN-EN ISO 9967:2016-02 PN-EN 761:2001 Rury z tworzyw sztucznych (Ø 160 mm – 800mm) Plastic pipes (Ø 160 mm – 800mm) Wskaznik pelzania Zakres: wielkosc odksztalcenia do 50 mm Proba pelzania Creep ratio Range: amount of deformation make 50 mm Creep test PN-EN ISO 9967:2016-02 PN-EN 761:2001","categories":["materials"],"row_index":255,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic pipes (Ø 160 mm – 800mm) Creep ratio Range: amount of deformation make 50 mm Creep test PN-EN ISO 9967:2016-02 PN-EN 761:2001"},{"_id":"6a5a55ef9af9f73f38250b9c","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Przewody rurowe z tworzyw sztucznych Plastic pipes","test_object_en":"Plastic pipes","methodology":"Odporność na równoczesne działanie cyklicznych zmian temperatury i zewnętrznego obciążenia Zakres średnic: (90 – 510) mm Cykliczne zmiany temperatury Resistance to combined temperature cycling and external loading Diameter range: (90÷510) mm Cyclic temperature changes","methodology_en":"Resistance to combined temperature cycling and external loading Diameter range: (90÷510) mm Cyclic temperature changes","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na równoczesne działanie cyklicznych zmian temperatury i zewnętrznego obciążenia Zakres średnic: (90 – 510) mm Cykliczne zmiany temperatury Resistance to combined temperature cycling and external loading Diameter range: (90÷510) mm Cyclic temperature changes","reference":"PN-EN ISO 13260:2012+A1:2017-11","norm_bases":["PN-EN ISO 13260:2012+A1:2017-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody rurowe z tworzyw sztucznych Plastic pipes Odporność na równoczesne działanie cyklicznych zmian temperatury i zewnętrznego obciążenia Zakres średnic: (90 – 510) mm Cykliczne zmiany temperatury Resistance to combined temperature cycling and external loading Diameter range: (90÷510) mm Cyclic temperature changes PN-EN ISO 13260:2012+A1:2017-11 Przewody rurowe z tworzyw sztucznych Plastic pipes Odpornosc na rownoczesne dzialanie cyklicznych zmian temperatury i zewnetrznego obciazenia Zakres srednic: (90 – 510) mm Cykliczne zmiany temperatury Resistance to combined temperature cycling and external loading Diameter range: (90÷510) mm Cyclic temperature changes PN-EN ISO 13260:2012+A1:2017-11","categories":["materials"],"row_index":256,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic pipes Resistance to combined temperature cycling and external loading Diameter range: (90÷510) mm Cyclic temperature changes PN-EN ISO 13260:2012+A1:2017-11"},{"_id":"6a5a55ef9af9f73f38250b9d","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Rury z tworzyw sztucznych (rury o średnicy zewnętrznej Ø =160 mm, 200 mm i 315 mm) Plastic pipes (pipes of diameter Ø =160 mm, 200 mm and 315 mm)","test_object_en":"Plastic pipes (pipes of diameter Ø =160 mm, 200 mm and 315 mm)","methodology":"Odporność na ścieranie Zakres: do 10 mm Próba ścierania Abrasion resistance Range: up to 10 mm Abrasion test","methodology_en":"Abrasion resistance Range: up to 10 mm Abrasion test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na ścieranie Zakres: do 10 mm Próba ścierania Abrasion resistance Range: up to 10 mm Abrasion test","reference":"PN-EN 295-3:2012","norm_bases":["PN-EN 295-3:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury z tworzyw sztucznych (rury o średnicy zewnętrznej Ø =160 mm, 200 mm i 315 mm) Plastic pipes (pipes of diameter Ø =160 mm, 200 mm and 315 mm) Odporność na ścieranie Zakres: do 10 mm Próba ścierania Abrasion resistance Range: up to 10 mm Abrasion test PN-EN 295-3:2012 Rury z tworzyw sztucznych (rury o srednicy zewnetrznej Ø =160 mm, 200 mm i 315 mm) Plastic pipes (pipes of diameter Ø =160 mm, 200 mm and 315 mm) Odpornosc na scieranie Zakres: do 10 mm Proba scierania Abrasion resistance Range: up to 10 mm Abrasion test PN-EN 295-3:2012","categories":["materials"],"row_index":257,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic pipes (pipes of diameter Ø =160 mm, 200 mm and 315 mm) Abrasion resistance Range: up to 10 mm Abrasion test PN-EN 295-3:2012"},{"_id":"6a5a55ef9af9f73f38250b9e","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Tworzywa sztuczne nieporowate Non-porous plastics","test_object_en":"Non-porous plastics","methodology":"Gęstość Zakres: (0,5 – 3) g/cm3 Metoda wagowa Density Range: (0,5 – 3) g/cm3 Weight method","methodology_en":"Density Range: (0,5 – 3) g/cm3 Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Gęstość Zakres: (0,5 – 3) g/cm3 Metoda wagowa Density Range: (0,5 – 3) g/cm3 Weight method","reference":"PN-EN ISO 1183-1:2019-05","norm_bases":["PN-EN ISO 1183-1:2019-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tworzywa sztuczne nieporowate Non-porous plastics Gęstość Zakres: (0,5 – 3) g/cm3 Metoda wagowa Density Range: (0,5 – 3) g/cm3 Weight method PN-EN ISO 1183-1:2019-05 Tworzywa sztuczne nieporowate Non-porous plastics Gestosc Zakres: (0,5 – 3) g/cm3 Metoda wagowa Density Range: (0,5 – 3) g/cm3 Weight method PN-EN ISO 1183-1:2019-05","categories":["materials"],"row_index":258,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Non-porous plastics Density Range: (0,5 – 3) g/cm3 Weight method PN-EN ISO 1183-1:2019-05"},{"_id":"6a5a55ef9af9f73f38250b9f","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Tworzywa sztuczne i guma Plastics and rubber","test_object_en":"Plastics and rubber","methodology":"Twardość Zakres: (0 – 98) ShA Metoda Shore’a Hardness Range: (0 – 98) ShA Shore hardness","methodology_en":"Hardness Range: (0 – 98) ShA Shore hardness","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Twardość Zakres: (0 – 98) ShA Metoda Shore’a Hardness Range: (0 – 98) ShA Shore hardness","reference":"PN-80/C-04238 PN-EN ISO 868:2005","norm_bases":["PN-80/C-04238 PN-EN ISO 868:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tworzywa sztuczne i guma Plastics and rubber Twardość Zakres: (0 – 98) ShA Metoda Shore’a Hardness Range: (0 – 98) ShA Shore hardness PN-80/C-04238 PN-EN ISO 868:2005 Tworzywa sztuczne i guma Plastics and rubber Twardosc Zakres: (0 – 98) ShA Metoda Shore’a Hardness Range: (0 – 98) ShA Shore hardness PN-80/C-04238 PN-EN ISO 868:2005","categories":["materials"],"row_index":259,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastics and rubber Hardness Range: (0 – 98) ShA Shore hardness PN-80/C-04238 PN-EN ISO 868:2005"},{"_id":"6a5a55ef9af9f73f38250ba0","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Guma Rubber","test_object_en":"Rubber","methodology":"Twardość Zakres: (20 – 80) ShA Metoda Shore’a Hardness Range: (20 – 80) ShA Shore hardness","methodology_en":"Hardness Range: (20 – 80) ShA Shore hardness","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Twardość Zakres: (20 – 80) ShA Metoda Shore’a Hardness Range: (20 – 80) ShA Shore hardness","reference":"ISO 7619-1:2010","norm_bases":["ISO 7619-1:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Guma Rubber Twardość Zakres: (20 – 80) ShA Metoda Shore’a Hardness Range: (20 – 80) ShA Shore hardness ISO 7619-1:2010 Guma Rubber Twardosc Zakres: (20 – 80) ShA Metoda Shore’a Hardness Range: (20 – 80) ShA Shore hardness ISO 7619-1:2010","categories":["materials"],"row_index":260,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rubber Hardness Range: (20 – 80) ShA Shore hardness ISO 7619-1:2010"},{"_id":"6a5a55ef9af9f73f38250ba1","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Rury i kształtki z tworzyw sztucznych System rur wielowarstwowych i złączek Plastic pipes and fittings System of multilayered pipes and fittings","test_object_en":"Plastic pipes and fittings System of multilayered pipes and fittings","methodology":"Odporność na cykliczne zmiany temperatury Zakres temperatury: do 95 ºC Resistance to temperature cycling Temperature range up to 95 ºC","methodology_en":"Resistance to temperature cycling Temperature range up to 95 ºC","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na cykliczne zmiany temperatury Zakres temperatury: do 95 ºC Resistance to temperature cycling Temperature range up to 95 ºC","reference":"PN-EN 12293:2002 PN-EN ISO 19893:2018-10","norm_bases":["PN-EN 12293:2002 PN-EN ISO 19893:2018-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury i kształtki z tworzyw sztucznych System rur wielowarstwowych i złączek Plastic pipes and fittings System of multilayered pipes and fittings Odporność na cykliczne zmiany temperatury Zakres temperatury: do 95 ºC Resistance to temperature cycling Temperature range up to 95 ºC PN-EN 12293:2002 PN-EN ISO 19893:2018-10 Rury i ksztaltki z tworzyw sztucznych System rur wielowarstwowych i zlaczek Plastic pipes and fittings System of multilayered pipes and fittings Odpornosc na cykliczne zmiany temperatury Zakres temperatury: do 95 ºC Resistance to temperature cycling Temperature range up to 95 ºC PN-EN 12293:2002 PN-EN ISO 19893:2018-10","categories":["materials"],"row_index":261,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic pipes and fittings System of multilayered pipes and fittings Resistance to temperature cycling Temperature range up to 95 ºC PN-EN 12293:2002 PN-EN ISO 19893:2018-10"},{"_id":"6a5a55ef9af9f73f38250ba2","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Taśmy przenośnikowe oraz połączenia klejone taśm Conveyor belts and glued joints of conveyor belts","test_object_en":"Conveyor belts and glued joints of conveyor belts","methodology":"Czas palenia i żarzenia Metoda płomieniowa Burning and glowing time Flame method","methodology_en":"Burning and glowing time Flame method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Czas palenia i żarzenia Metoda płomieniowa Burning and glowing time Flame method","reference":"PN-93/C-05013 p. 2.1 PN-98/C-05019 p. 3.1 PN-EN ISO 340:2013-07 PN-EN ISO 340:2022-12","norm_bases":["PN-93/C-05013 p. 2.1 PN-98/C-05019 p. 3.1 PN-EN ISO 340:2013-07 PN-EN ISO 340:2022-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Taśmy przenośnikowe oraz połączenia klejone taśm Conveyor belts and glued joints of conveyor belts Czas palenia i żarzenia Metoda płomieniowa Burning and glowing time Flame method PN-93/C-05013 p. 2.1 PN-98/C-05019 p. 3.1 PN-EN ISO 340:2013-07 PN-EN ISO 340:2022-12 Tasmy przenosnikowe oraz polaczenia klejone tasm Conveyor belts and glued joints of conveyor belts Czas palenia i zarzenia Metoda plomieniowa Burning and glowing time Flame method PN-93/C-05013 p. 2.1 PN-98/C-05019 p. 3.1 PN-EN ISO 340:2013-07 PN-EN ISO 340:2022-12","categories":["other"],"row_index":262,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Conveyor belts and glued joints of conveyor belts Burning and glowing time Flame method PN-93/C-05013 p. 2.1 PN-98/C-05019 p. 3.1 PN-EN ISO 340:2013-07 PN-EN ISO 340:2022-12"},{"_id":"6a5a55ef9af9f73f38250ba3","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Materiały niemetalowe Non-metallic materials","test_object_en":"Non-metallic materials","methodology":"Czas palenia Metoda płomieniowa Czas przyłożenia płomienia 10 s (zgodnie z PN-EN ISO/IEC 80079-38: 2017-02 p. 6.2) Burning time Flame method Time of applying the flame 10 s (in accordance with PN-EN ISO/IEC 80079-38:2017-02 p. 6.2)","methodology_en":"Burning time Flame method Time of applying the flame 10 s (in accordance with PN-EN ISO/IEC 80079-38:2017-02 p. 6.2)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Czas palenia Metoda płomieniowa Czas przyłożenia płomienia 10 s (zgodnie z PN-EN ISO/IEC 80079-38: 2017-02 p. 6.2) Burning time Flame method Time of applying the flame 10 s (in accordance with PN-EN ISO/IEC 80079-38:2017-02 p. 6.2)","reference":"PN-EN ISO 340:2013-07 PN-EN ISO 340:2022-12","norm_bases":["PN-EN ISO 340:2013-07 PN-EN ISO 340:2022-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały niemetalowe Non-metallic materials Czas palenia Metoda płomieniowa Czas przyłożenia płomienia 10 s (zgodnie z PN-EN ISO/IEC 80079-38: 2017-02 p. 6.2) Burning time Flame method Time of applying the flame 10 s (in accordance with PN-EN ISO/IEC 80079-38:2017-02 p. 6.2) PN-EN ISO 340:2013-07 PN-EN ISO 340:2022-12 Materialy niemetalowe Non-metallic materials Czas palenia Metoda plomieniowa Czas przylozenia plomienia 10 s (zgodnie z PN-EN ISO/IEC 80079-38: 2017-02 p. 6.2) Burning time Flame method Time of applying the flame 10 s (in accordance with PN-EN ISO/IEC 80079-38:2017-02 p. 6.2) PN-EN ISO 340:2013-07 PN-EN ISO 340:2022-12","categories":["materials"],"row_index":263,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Non-metallic materials Burning time Flame method Time of applying the flame 10 s (in accordance with PN-EN ISO/IEC 80079-38:2017-02 p. 6.2) PN-EN ISO 340:2013-07 PN-EN ISO 340:2022-12"},{"_id":"6a5a55ef9af9f73f38250ba4","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Materiały niemetalowe stałe i porowate o gęstości pozornej ≥ 250 kg/m3 Solid and porous non-metallic materials with an apparent density of ≥ 250 kg/m3","test_object_en":"Solid and porous non-metallic materials with an apparent density of ≥ 250 kg/m3","methodology":"Liniowa szybkość palenia Metoda A: próba poziomego palenia się, czas palenia / żarzenia po usunięciu płomienia (czas dalszego palenia / dalszego żarzenia) Metoda B: próba pionowego palenia się Linear burning rate Method A: horizontal burning test, burning / glowing time after removing the flame (time of further burning / further glowing) Method B: vertical burning test","methodology_en":"Linear burning rate Method A: horizontal burning test, burning / glowing time after removing the flame (time of further burning / further glowing) Method B: vertical burning test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liniowa szybkość palenia Metoda A: próba poziomego palenia się, czas palenia / żarzenia po usunięciu płomienia (czas dalszego palenia / dalszego żarzenia) Metoda B: próba pionowego palenia się Linear burning rate Method A: horizontal burning test, burning / glowing time after removing the flame (time of further burning / further glowing) Method B: vertical burning test","reference":"PN-EN 60695-11-10:2014-02","norm_bases":["PN-EN 60695-11-10:2014-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały niemetalowe stałe i porowate o gęstości pozornej ≥ 250 kg/m3 Solid and porous non-metallic materials with an apparent density of ≥ 250 kg/m3 Liniowa szybkość palenia Metoda A: próba poziomego palenia się, czas palenia / żarzenia po usunięciu płomienia (czas dalszego palenia / dalszego żarzenia) Metoda B: próba pionowego palenia się Linear burning rate Method A: horizontal burning test, burning / glowing time after removing the flame (time of further burning / further glowing) Method B: vertical burning test PN-EN 60695-11-10:2014-02 Materialy niemetalowe stale i porowate o gestosci pozornej ≥ 250 kg/m3 Solid and porous non-metallic materials with an apparent density of ≥ 250 kg/m3 Liniowa szybkosc palenia Metoda A: proba poziomego palenia sie, czas palenia / zarzenia po usunieciu plomienia (czas dalszego palenia / dalszego zarzenia) Metoda B: proba pionowego palenia sie Linear burning rate Method A: horizontal burning test, burning / glowing time after removing the flame (time of further burning / further glowing) Method B: vertical burning test PN-EN 60695-11-10:2014-02","categories":["materials"],"row_index":264,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid and porous non-metallic materials with an apparent density of ≥ 250 kg/m3 Linear burning rate Method A: horizontal burning test, burning / glowing time after removing the flame (time of further burning / further glowing) Method B: vertical burning test PN-EN 60695-11-10:2014-02"},{"_id":"6a5a55ef9af9f73f38250ba5","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Cienkie giętkie tworzywa sztuczne o grubości ≤ 5,5 mm Thin pliable plastics with a thickness of ≤ 5,5 mm","test_object_en":"Thin pliable plastics with a thickness of ≤ 5,5 mm","methodology":"Czas płomienia / żarzenia resztkowego Metoda pionowego palenia się Flame / residual glow time Vertical burning method","methodology_en":"Flame / residual glow time Vertical burning method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Czas płomienia / żarzenia resztkowego Metoda pionowego palenia się Flame / residual glow time Vertical burning method","reference":"PN-EN ISO 9773:2003+A1:2005","norm_bases":["PN-EN ISO 9773:2003+A1:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Cienkie giętkie tworzywa sztuczne o grubości ≤ 5,5 mm Thin pliable plastics with a thickness of ≤ 5,5 mm Czas płomienia / żarzenia resztkowego Metoda pionowego palenia się Flame / residual glow time Vertical burning method PN-EN ISO 9773:2003+A1:2005 Cienkie gietkie tworzywa sztuczne o grubosci ≤ 5,5 mm Thin pliable plastics with a thickness of ≤ 5,5 mm Czas plomienia / zarzenia resztkowego Metoda pionowego palenia sie Flame / residual glow time Vertical burning method PN-EN ISO 9773:2003+A1:2005","categories":["materials"],"row_index":265,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Thin pliable plastics with a thickness of ≤ 5,5 mm Flame / residual glow time Vertical burning method PN-EN ISO 9773:2003+A1:2005"},{"_id":"6a5a55ef9af9f73f38250ba6","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Tworzywa sztuczne przeznaczone na elementy maszyn, farby, powłoki w tym powłoki malarskie, kleje, żywice i materiały wiążące organiczne, ładunki żywiczne klejowe oraz gotowe wyroby Plastics for machine elements, paints, coatings, including paint coatings, adhesives, resins and organic binders, adhesive resin loads and finished products","test_object_en":"Plastics for machine elements, paints, coatings, including paint coatings, adhesives, resins and organic binders, adhesive resin loads and finished products","methodology":"Czas palenia i żarzenia Metoda płomieniowa Burning and glowing time Flame method","methodology_en":"Burning and glowing time Flame method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Czas palenia i żarzenia Metoda płomieniowa Burning and glowing time Flame method","reference":"BL-6/ZLGIG/PB-3 edycja 3 z dnia 04.09.2023 r. BL-6/ZLGIG/PB-3 3rd edition of 4 September 2023","norm_bases":["BL-6/ZLGIG/PB-3 edycja 3 z dnia 04.09.2023 r. BL-6/ZLGIG/PB-3 3rd edition of 4 September 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tworzywa sztuczne przeznaczone na elementy maszyn, farby, powłoki w tym powłoki malarskie, kleje, żywice i materiały wiążące organiczne, ładunki żywiczne klejowe oraz gotowe wyroby Plastics for machine elements, paints, coatings, including paint coatings, adhesives, resins and organic binders, adhesive resin loads and finished products Czas palenia i żarzenia Metoda płomieniowa Burning and glowing time Flame method BL-6/ZLGIG/PB-3 edycja 3 z dnia 04.09.2023 r. BL-6/ZLGIG/PB-3 3rd edition of 4 September 2023 Tworzywa sztuczne przeznaczone na elementy maszyn, farby, powloki w tym powloki malarskie, kleje, zywice i materialy wiazace organiczne, ladunki zywiczne klejowe oraz gotowe wyroby Plastics for machine elements, paints, coatings, including paint coatings, adhesives, resins and organic binders, adhesive resin loads and finished products Czas palenia i zarzenia Metoda plomieniowa Burning and glowing time Flame method BL-6/ZLGIG/PB-3 edycja 3 z dnia 04.09.2023 r. BL-6/ZLGIG/PB-3 3rd edition of 4 September 2023","categories":["materials"],"row_index":266,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastics for machine elements, paints, coatings, including paint coatings, adhesives, resins and organic binders, adhesive resin loads and finished products Burning and glowing time Flame method BL-6/ZLGIG/PB-3 edycja 3 z dnia 04.09.2023 r. BL-6/ZLGIG/PB-3 3rd edition of 4 September 2023"},{"_id":"6a5a55ef9af9f73f38250ba7","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Materiały niemetalowe spienione o gęstości pozornej < 250 kg/m3 Non-metallic foamed materials with an apparent density of <250 kg/m3","test_object_en":"Non-metallic foamed materials with an apparent density of <250 kg/m3","methodology":"Czas palenia Metoda płomieniowa Burning time Flame method","methodology_en":"Burning time Flame method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Czas palenia Metoda płomieniowa Burning time Flame method","reference":"BL-6/ZLGIG/PB-5 edycja 2 z dnia 25.08.2023 r. BL-6/ZLGIG/PB-5 2nd edition of 25 August 2023","norm_bases":["BL-6/ZLGIG/PB-5 edycja 2 z dnia 25.08.2023 r. BL-6/ZLGIG/PB-5 2nd edition of 25 August 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały niemetalowe spienione o gęstości pozornej < 250 kg/m3 Non-metallic foamed materials with an apparent density of <250 kg/m3 Czas palenia Metoda płomieniowa Burning time Flame method BL-6/ZLGIG/PB-5 edycja 2 z dnia 25.08.2023 r. BL-6/ZLGIG/PB-5 2nd edition of 25 August 2023 Materialy niemetalowe spienione o gestosci pozornej < 250 kg/m3 Non-metallic foamed materials with an apparent density of <250 kg/m3 Czas palenia Metoda plomieniowa Burning time Flame method BL-6/ZLGIG/PB-5 edycja 2 z dnia 25.08.2023 r. BL-6/ZLGIG/PB-5 2nd edition of 25 August 2023","categories":["materials"],"row_index":267,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Non-metallic foamed materials with an apparent density of <250 kg/m3 Burning time Flame method BL-6/ZLGIG/PB-5 edycja 2 z dnia 25.08.2023 r. BL-6/ZLGIG/PB-5 2nd edition of 25 August 2023"},{"_id":"6a5a55ef9af9f73f38250ba8","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Tworzywa sztuczne Plastics","test_object_en":"Plastics","methodology":"Czas i temperatura indukcji utleniania (OIT) Metoda różnicowej kalorymetrii skaningowej (DSC) Oxidation induction time and temperature (OIT) Differential Scanning Calorimetry method (DSC)","methodology_en":"Oxidation induction time and temperature (OIT) Differential Scanning Calorimetry method (DSC)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Czas i temperatura indukcji utleniania (OIT) Metoda różnicowej kalorymetrii skaningowej (DSC) Oxidation induction time and temperature (OIT) Differential Scanning Calorimetry method (DSC)","reference":"PN-EN ISO 11357-6:2018-04","norm_bases":["PN-EN ISO 11357-6:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tworzywa sztuczne Plastics Czas i temperatura indukcji utleniania (OIT) Metoda różnicowej kalorymetrii skaningowej (DSC) Oxidation induction time and temperature (OIT) Differential Scanning Calorimetry method (DSC) PN-EN ISO 11357-6:2018-04 Tworzywa sztuczne Plastics Czas i temperatura indukcji utleniania (OIT) Metoda roznicowej kalorymetrii skaningowej (DSC) Oxidation induction time and temperature (OIT) Differential Scanning Calorimetry method (DSC) PN-EN ISO 11357-6:2018-04","categories":["materials"],"row_index":268,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastics Oxidation induction time and temperature (OIT) Differential Scanning Calorimetry method (DSC) PN-EN ISO 11357-6:2018-04","search_zh":"塑料 Plastics PN-EN ISO 11357-6:2018-04","test_object_zh":"塑料 Plastics"},{"_id":"6a5a55ef9af9f73f38250ba9","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Tworzywa sztuczne Plastics","test_object_en":"Plastics","methodology":"Wskaźnik tlenowy Oxygen index","methodology_en":"Oxygen index","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik tlenowy Oxygen index","reference":"PN-EN ISO 4589-2:2017-06","norm_bases":["PN-EN ISO 4589-2:2017-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tworzywa sztuczne Plastics Wskaźnik tlenowy Oxygen index PN-EN ISO 4589-2:2017-06 Tworzywa sztuczne Plastics Wskaznik tlenowy Oxygen index PN-EN ISO 4589-2:2017-06","categories":["materials"],"row_index":269,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastics Oxygen index PN-EN ISO 4589-2:2017-06","search_zh":"塑料 Plastics PN-EN ISO 4589-2:2017-06","test_object_zh":"塑料 Plastics"},{"_id":"6a5a55ef9af9f73f38250baa","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Taśmy przenośnikowe Conveyor belts","test_object_en":"Conveyor belts","methodology":"Długość niespalonego odcinka Metoda sztolni modelowej Length of the unburned section Model adit method","methodology_en":"Length of the unburned section Model adit method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Długość niespalonego odcinka Metoda sztolni modelowej Length of the unburned section Model adit method","reference":"PN-93/C-05013 p. 2.4","norm_bases":["PN-93/C-05013 p. 2.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Taśmy przenośnikowe Conveyor belts Długość niespalonego odcinka Metoda sztolni modelowej Length of the unburned section Model adit method PN-93/C-05013 p. 2.4 Tasmy przenosnikowe Conveyor belts Dlugosc niespalonego odcinka Metoda sztolni modelowej Length of the unburned section Model adit method PN-93/C-05013 p. 2.4","categories":["other"],"row_index":270,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Conveyor belts Length of the unburned section Model adit method PN-93/C-05013 p. 2.4"},{"_id":"6a5a55ef9af9f73f38250bab","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Taśmy przenośnikowe Conveyor belts","test_object_en":"Conveyor belts","methodology":"Najwyższa temperatura bębna ciernego oraz obecność płomienia i żaru Metoda cierna Highest friction drum temperature and presence of flame and heat Friction method","methodology_en":"Highest friction drum temperature and presence of flame and glow Friction method Highest friction drum temperature and presence of flame and heat Friction method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Najwyższa temperatura bębna ciernego oraz obecność płomienia i żaru Metoda cierna Highest friction drum temperature and presence of flame and heat Friction method","reference":"PN-EN ISO 20238:2019-05","norm_bases":["PN-EN ISO 20238:2019-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Taśmy przenośnikowe Conveyor belts Najwyższa temperatura bębna ciernego oraz obecność płomienia i żaru Metoda cierna Highest friction drum temperature and presence of flame and heat Friction method PN-EN ISO 20238:2019-05 Tasmy przenosnikowe Conveyor belts Najwyzsza temperatura bebna ciernego oraz obecnosc plomienia i zaru Metoda cierna Highest friction drum temperature and presence of flame and heat Friction method PN-EN ISO 20238:2019-05","categories":["other"],"row_index":271,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Conveyor belts Highest friction drum temperature and presence of flame and glow Friction method Highest friction drum temperature and presence of flame and heat Friction method PN-EN ISO 20238:2019-05"},{"_id":"6a5a55ef9af9f73f38250bac","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Materiały niemetalowe (wielkości próbek do 200 mg) Non-metallic materials (sample sizes up to 200 mg)","test_object_en":"Non-metallic materials (sample sizes up to 200 mg)","methodology":"Ubytek masy Szybkość ubytku masy Temperatury przemian fizyko- chemicznych Efekty termiczne przemian fizyko- chemicznych (jakościowo) Zakres temperatur: (20 – 1200) ºC Loss of weight The rate of weight loss Temperatures of physico-chemical transformations Thermal effects of physico-chemical transformations (qualitative) Temperature range: (20 – 1200) ºC","methodology_en":"Loss of weight The rate of weight loss Temperatures of physico-chemical transformations Thermal effects of physico-chemical transformations (qualitative) Temperature range: (20 – 1200) ºC","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ubytek masy Szybkość ubytku masy Temperatury przemian fizyko- chemicznych Efekty termiczne przemian fizyko- chemicznych (jakościowo) Zakres temperatur: (20 – 1200) ºC Loss of weight The rate of weight loss Temperatures of physico-chemical transformations Thermal effects of physico-chemical transformations (qualitative) Temperature range: (20 – 1200) ºC","reference":"BL-6/ZLGIG/PB-16 edycja 2 z dnia 25.08.2023 r. BL-6/ZLGIG/PB-16 2nd edition of 25 August 2023","norm_bases":["BL-6/ZLGIG/PB-16 edycja 2 z dnia 25.08.2023 r. BL-6/ZLGIG/PB-16 2nd edition of 25 August 2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały niemetalowe (wielkości próbek do 200 mg) Non-metallic materials (sample sizes up to 200 mg) Ubytek masy Szybkość ubytku masy Temperatury przemian fizyko- chemicznych Efekty termiczne przemian fizyko- chemicznych (jakościowo) Zakres temperatur: (20 – 1200) ºC Loss of weight The rate of weight loss Temperatures of physico-chemical transformations Thermal effects of physico-chemical transformations (qualitative) Temperature range: (20 – 1200) ºC BL-6/ZLGIG/PB-16 edycja 2 z dnia 25.08.2023 r. BL-6/ZLGIG/PB-16 2nd edition of 25 August 2023 Materialy niemetalowe (wielkosci probek do 200 mg) Non-metallic materials (sample sizes up to 200 mg) Ubytek masy Szybkosc ubytku masy Temperatury przemian fizyko- chemicznych Efekty termiczne przemian fizyko- chemicznych (jakosciowo) Zakres temperatur: (20 – 1200) ºC Loss of weight The rate of weight loss Temperatures of physico-chemical transformations Thermal effects of physico-chemical transformations (qualitative) Temperature range: (20 – 1200) ºC BL-6/ZLGIG/PB-16 edycja 2 z dnia 25.08.2023 r. BL-6/ZLGIG/PB-16 2nd edition of 25 August 2023","categories":["materials"],"row_index":272,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Non-metallic materials (sample sizes up to 200 mg) Loss of weight The rate of weight loss Temperatures of physico-chemical transformations Thermal effects of physico-chemical transformations (qualitative) Temperature range: (20 – 1200) ºC BL-6/ZLGIG/PB-16 edycja 2 z dnia 25.08.2023 r. BL-6/ZLGIG/PB-16 2nd edition of 25 August 2023"},{"_id":"6a5a55ef9af9f73f38250bad","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Ścieki Sewage","test_object_en":"Sewage","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura ścieków, pobranej próbki ścieków  Zakres: (0 – 50) C Sampling for Chemical and Physical Analysis Manual Method Automatic Method Sewage Temperature / Sample Temperature  Range: (0 – 50) °C","methodology_en":"Sampling for Chemical and Physical Analysis Manual Method Automatic Method Sewage Temperature / Sample Temperature  Range: (0 – 50) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura ścieków, pobranej próbki ścieków  Zakres: (0 – 50) C Sampling for Chemical and Physical Analysis Manual Method Automatic Method Sewage Temperature / Sample Temperature  Range: (0 – 50) °C","reference":"PN-ISO 5667-10:2021-11 SC/ZLGIG/PB.01 edycja 1 z dnia 01.08.2025 PN-ISO 5667-10:2021-11 SC/ZLGIG/PB.01 1st edition of 01.08.2025","norm_bases":["PN-ISO 5667-10:2021-11 SC/ZLGIG/PB.01 edycja 1 z dnia 01.08.2025 PN-ISO 5667-10:2021-11 SC/ZLGIG/PB.01 1st edition of 01.08.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Sewage Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura ścieków, pobranej próbki ścieków  Zakres: (0 – 50) C Sampling for Chemical and Physical Analysis Manual Method Automatic Method Sewage Temperature / Sample Temperature  Range: (0 – 50) °C PN-ISO 5667-10:2021-11 SC/ZLGIG/PB.01 edycja 1 z dnia 01.08.2025 PN-ISO 5667-10:2021-11 SC/ZLGIG/PB.01 1st edition of 01.08.2025 Scieki Sewage Pobieranie probek do badan chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura sciekow, pobranej probki sciekow  Zakres: (0 – 50) C Sampling for Chemical and Physical Analysis Manual Method Automatic Method Sewage Temperature / Sample Temperature  Range: (0 – 50) °C PN-ISO 5667-10:2021-11 SC/ZLGIG/PB.01 edycja 1 z dnia 01.08.2025 PN-ISO 5667-10:2021-11 SC/ZLGIG/PB.01 1st edition of 01.08.2025","categories":["water"],"row_index":273,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage Sampling for Chemical and Physical Analysis Manual Method Automatic Method Sewage Temperature / Sample Temperature  Range: (0 – 50) °C PN-ISO 5667-10:2021-11 SC/ZLGIG/PB.01 edycja 1 z dnia 01.08.2025 PN-ISO 5667-10:2021-11 SC/ZLGIG/PB.01 1st edition of 01.08.2025","search_zh":"废水 Sewage PN-ISO 5667-10:2021-11 SC/ZLGIG/PB.01 edycja 1 z dnia 01.08.2025 PN-ISO 5667-10:2021-11 SC/ZLGIG/PB.01 1st edition of 01.08.2025","test_object_zh":"废水 Sewage"},{"_id":"6a5a55ef9af9f73f38250bae","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda Water","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody, pobranej próbki wody  Zakres: (0 – 50) C Sample collection for chemical and physical testing Water sample temperature (measured upon collection)  Measurement range: 0 – 50 °C","methodology_en":"Sample collection for chemical and physical testing Water sample temperature (measured upon collection)  Measurement range: 0 – 50 °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody, pobranej próbki wody  Zakres: (0 – 50) C Sample collection for chemical and physical testing Water sample temperature (measured upon collection)  Measurement range: 0 – 50 °C","reference":"PN-ISO 5667-4:2017-10 PN-EN ISO 5667-6:2016-12 SC/ZLGIG/PB.01 edycja 1 z dnia 01.08.2025 PN-ISO 5667-4:2017-10 PN-EN ISO 5667-6:2016-12 SC/ZLGIG/PB.01 1st edition of 01.08.2025","norm_bases":["PN-ISO 5667-4:2017-10 PN-EN ISO 5667-6:2016-12 SC/ZLGIG/PB.01 edycja 1 z dnia 01.08.2025 PN-ISO 5667-4:2017-10 PN-EN ISO 5667-6:2016-12 SC/ZLGIG/PB.01 1st edition of 01.08.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Water Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody, pobranej próbki wody  Zakres: (0 – 50) C Sample collection for chemical and physical testing Water sample temperature (measured upon collection)  Measurement range: 0 – 50 °C PN-ISO 5667-4:2017-10 PN-EN ISO 5667-6:2016-12 SC/ZLGIG/PB.01 edycja 1 z dnia 01.08.2025 PN-ISO 5667-4:2017-10 PN-EN ISO 5667-6:2016-12 SC/ZLGIG/PB.01 1st edition of 01.08.2025 Woda Water Pobieranie probek do badan chemicznych i fizycznych Temperatura wody, pobranej probki wody  Zakres: (0 – 50) C Sample collection for chemical and physical testing Water sample temperature (measured upon collection)  Measurement range: 0 – 50 °C PN-ISO 5667-4:2017-10 PN-EN ISO 5667-6:2016-12 SC/ZLGIG/PB.01 edycja 1 z dnia 01.08.2025 PN-ISO 5667-4:2017-10 PN-EN ISO 5667-6:2016-12 SC/ZLGIG/PB.01 1st edition of 01.08.2025","categories":["water"],"row_index":274,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Sample collection for chemical and physical testing Water sample temperature (measured upon collection)  Measurement range: 0 – 50 °C PN-ISO 5667-4:2017-10 PN-EN ISO 5667-6:2016-12 SC/ZLGIG/PB.01 edycja 1 z dnia 01.08.2025 PN-ISO 5667-4:2017-10 PN-EN ISO 5667-6:2016-12 SC/ZLGIG/PB.01 1st edition of 01.08.2025","search_zh":"水 Water PN-ISO 5667-4:2017-10 PN-EN ISO 5667-6:2016-12 SC/ZLGIG/PB.01 edycja 1 z dnia 01.08.2025 PN-ISO 5667-4:2017-10 PN-EN ISO 5667-6:2016-12 SC/ZLGIG/PB.01 1st edition of 01.08.2025","test_object_zh":"水 Water"},{"_id":"6a5a55ef9af9f73f38250baf","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda Water","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody  Zakres: (0 - 50) C Sample Collection for Chemical and Physical Testing Collected Water Sample Temperature  Permissible Range: 0–50 °C","methodology_en":"Sample Collection for Chemical and Physical Testing Collected Water Sample Temperature  Permissible Range: 0–50 °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody  Zakres: (0 - 50) C Sample Collection for Chemical and Physical Testing Collected Water Sample Temperature  Permissible Range: 0–50 °C","reference":"PN-ISO 5667-11:2017-10 SC/ZLGIG/PB.01 edycja 1 z dnia 01.08.2025 PN-ISO 5667-11:2017-10 SC/ZLGIG/PB.01 1st edition of 01.08.2025","norm_bases":["PN-ISO 5667-11:2017-10 SC/ZLGIG/PB.01 edycja 1 z dnia 01.08.2025 PN-ISO 5667-11:2017-10 SC/ZLGIG/PB.01 1st edition of 01.08.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Water Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody  Zakres: (0 - 50) C Sample Collection for Chemical and Physical Testing Collected Water Sample Temperature  Permissible Range: 0–50 °C PN-ISO 5667-11:2017-10 SC/ZLGIG/PB.01 edycja 1 z dnia 01.08.2025 PN-ISO 5667-11:2017-10 SC/ZLGIG/PB.01 1st edition of 01.08.2025 Woda Water Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody  Zakres: (0 - 50) C Sample Collection for Chemical and Physical Testing Collected Water Sample Temperature  Permissible Range: 0–50 °C PN-ISO 5667-11:2017-10 SC/ZLGIG/PB.01 edycja 1 z dnia 01.08.2025 PN-ISO 5667-11:2017-10 SC/ZLGIG/PB.01 1st edition of 01.08.2025","categories":["water"],"row_index":275,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Sample Collection for Chemical and Physical Testing Collected Water Sample Temperature  Permissible Range: 0–50 °C PN-ISO 5667-11:2017-10 SC/ZLGIG/PB.01 edycja 1 z dnia 01.08.2025 PN-ISO 5667-11:2017-10 SC/ZLGIG/PB.01 1st edition of 01.08.2025","search_zh":"水 Water PN-ISO 5667-11:2017-10 SC/ZLGIG/PB.01 edycja 1 z dnia 01.08.2025 PN-ISO 5667-11:2017-10 SC/ZLGIG/PB.01 1st edition of 01.08.2025","test_object_zh":"水 Water"},{"_id":"6a5a55ef9af9f73f38250bb0","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda Water","test_object_en":"Water","methodology":"Stężenie tlenu rozpuszczonego  Zakres: (0,5 – 20,0) mg/l Metoda elektrochemiczna Dissolved Oxygen Concentration  Range: 0.5 – 20.0 mg/L Measurement Method: Electrochemical","methodology_en":"Dissolved Oxygen Concentration  Range: 0.5 – 20.0 mg/L Measurement Method: Electrochemical","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenu rozpuszczonego  Zakres: (0,5 – 20,0) mg/l Metoda elektrochemiczna Dissolved Oxygen Concentration  Range: 0.5 – 20.0 mg/L Measurement Method: Electrochemical","reference":"PN-EN ISO 5814:2013-04 PN-EN ISO 5814:2013-04","norm_bases":["PN-EN ISO 5814:2013-04 PN-EN ISO 5814:2013-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Water Stężenie tlenu rozpuszczonego  Zakres: (0,5 – 20,0) mg/l Metoda elektrochemiczna Dissolved Oxygen Concentration  Range: 0.5 – 20.0 mg/L Measurement Method: Electrochemical PN-EN ISO 5814:2013-04 PN-EN ISO 5814:2013-04 Woda Water Stezenie tlenu rozpuszczonego  Zakres: (0,5 – 20,0) mg/l Metoda elektrochemiczna Dissolved Oxygen Concentration  Range: 0.5 – 20.0 mg/L Measurement Method: Electrochemical PN-EN ISO 5814:2013-04 PN-EN ISO 5814:2013-04","categories":["water"],"row_index":276,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Dissolved Oxygen Concentration  Range: 0.5 – 20.0 mg/L Measurement Method: Electrochemical PN-EN ISO 5814:2013-04 PN-EN ISO 5814:2013-04","search_zh":"水 Water PN-EN ISO 5814:2013-04 PN-EN ISO 5814:2013-04","test_object_zh":"水 Water"},{"_id":"6a5a55ef9af9f73f38250bb1","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi Drinking water","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody  Zakres: (0 – 50) C Sampling for Chemical and Physical Analysis Temperature of the Collected Water Sample  Range: (0 – 50) °C","methodology_en":"Sampling for Chemical and Physical Analysis Temperature of the Collected Water Sample  Range: (0 – 50) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody  Zakres: (0 – 50) C Sampling for Chemical and Physical Analysis Temperature of the Collected Water Sample  Range: (0 – 50) °C","reference":"PN-ISO 5667-5:2017-10 SC/ZLGIG/PB.01 edycja 1 z dnia 01.08.2025 PN-ISO 5667-5:2017-10 SC/ZLGIG/PB.01 1st edition of 01.08.2025","norm_bases":["PN-ISO 5667-5:2017-10 SC/ZLGIG/PB.01 edycja 1 z dnia 01.08.2025 PN-ISO 5667-5:2017-10 SC/ZLGIG/PB.01 1st edition of 01.08.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Drinking water Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody  Zakres: (0 – 50) C Sampling for Chemical and Physical Analysis Temperature of the Collected Water Sample  Range: (0 – 50) °C PN-ISO 5667-5:2017-10 SC/ZLGIG/PB.01 edycja 1 z dnia 01.08.2025 PN-ISO 5667-5:2017-10 SC/ZLGIG/PB.01 1st edition of 01.08.2025 Woda do spozycia przez ludzi Drinking water Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody  Zakres: (0 – 50) C Sampling for Chemical and Physical Analysis Temperature of the Collected Water Sample  Range: (0 – 50) °C PN-ISO 5667-5:2017-10 SC/ZLGIG/PB.01 edycja 1 z dnia 01.08.2025 PN-ISO 5667-5:2017-10 SC/ZLGIG/PB.01 1st edition of 01.08.2025","categories":["water"],"row_index":277,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Sampling for Chemical and Physical Analysis Temperature of the Collected Water Sample  Range: (0 – 50) °C PN-ISO 5667-5:2017-10 SC/ZLGIG/PB.01 edycja 1 z dnia 01.08.2025 PN-ISO 5667-5:2017-10 SC/ZLGIG/PB.01 1st edition of 01.08.2025"},{"_id":"6a5a55ef9af9f73f38250bb2","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi Drinking water","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań mikrobiologicznych Temperatura pobranej próbki wody  Zakres: (0 – 50) C Sampling for Microbiological Analysis Temperature of the Collected Water Sample  Range: (0 – 50) °C","methodology_en":"Sampling for Microbiological Analysis Temperature of the Collected Water Sample  Range: (0 – 50) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych Temperatura pobranej próbki wody  Zakres: (0 – 50) C Sampling for Microbiological Analysis Temperature of the Collected Water Sample  Range: (0 – 50) °C","reference":"PN-EN ISO 19458:2007 SC/ZLGIG/PB.01 edycja 1 z dnia 01.08.2025 PN-EN ISO 19458:2007 SC/ZLGIG/PB.01 1st edition of 01.08.2025","norm_bases":["PN-EN ISO 19458:2007 SC/ZLGIG/PB.01 edycja 1 z dnia 01.08.2025 PN-EN ISO 19458:2007 SC/ZLGIG/PB.01 1st edition of 01.08.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Drinking water Pobieranie próbek do badań mikrobiologicznych Temperatura pobranej próbki wody  Zakres: (0 – 50) C Sampling for Microbiological Analysis Temperature of the Collected Water Sample  Range: (0 – 50) °C PN-EN ISO 19458:2007 SC/ZLGIG/PB.01 edycja 1 z dnia 01.08.2025 PN-EN ISO 19458:2007 SC/ZLGIG/PB.01 1st edition of 01.08.2025 Woda do spozycia przez ludzi Drinking water Pobieranie probek do badan mikrobiologicznych Temperatura pobranej probki wody  Zakres: (0 – 50) C Sampling for Microbiological Analysis Temperature of the Collected Water Sample  Range: (0 – 50) °C PN-EN ISO 19458:2007 SC/ZLGIG/PB.01 edycja 1 z dnia 01.08.2025 PN-EN ISO 19458:2007 SC/ZLGIG/PB.01 1st edition of 01.08.2025","categories":["water","microbiology"],"row_index":278,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Sampling for Microbiological Analysis Temperature of the Collected Water Sample  Range: (0 – 50) °C PN-EN ISO 19458:2007 SC/ZLGIG/PB.01 edycja 1 z dnia 01.08.2025 PN-EN ISO 19458:2007 SC/ZLGIG/PB.01 1st edition of 01.08.2025"},{"_id":"6a5a55ef9af9f73f38250bb3","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Ścieki, woda Sewage, water","test_object_en":"Sewage, water","methodology":"pH  Zakres: 2,0 – 12,0 Metoda potencjometryczna pH  Range: 2.0 – 12.0 Method: Potentiometric","methodology_en":"pH  Range: 2.0 – 12.0 Method: Potentiometric","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH  Zakres: 2,0 – 12,0 Metoda potencjometryczna pH  Range: 2.0 – 12.0 Method: Potentiometric","reference":"PN-EN ISO 10523:2012 PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012 PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Sewage, water pH  Zakres: 2,0 – 12,0 Metoda potencjometryczna pH  Range: 2.0 – 12.0 Method: Potentiometric PN-EN ISO 10523:2012 PN-EN ISO 10523:2012 Scieki, woda Sewage, water pH  Zakres: 2,0 – 12,0 Metoda potencjometryczna pH  Range: 2.0 – 12.0 Method: Potentiometric PN-EN ISO 10523:2012 PN-EN ISO 10523:2012","categories":["water"],"row_index":279,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage, water pH  Range: 2.0 – 12.0 Method: Potentiometric PN-EN ISO 10523:2012 PN-EN ISO 10523:2012"},{"_id":"6a5a55ef9af9f73f38250bb4","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Ścieki, woda Sewage, water","test_object_en":"Sewage, water","methodology":"Przewodność elektryczna właściwa w temp. (0 – 80) C  Zakres: (10 – 110000) μS/cm Metoda konduktometryczna Specific Electrical Conductivity at Temperature (0 – 80) °C  Range: (10 – 110,000) μS/cm Method: Conductometric","methodology_en":"Specific Electrical Conductivity at Temperature (0 – 80) °C  Range: (10 – 110,000) μS/cm Method: Conductometric","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa w temp. (0 – 80) C  Zakres: (10 – 110000) μS/cm Metoda konduktometryczna Specific Electrical Conductivity at Temperature (0 – 80) °C  Range: (10 – 110,000) μS/cm Method: Conductometric","reference":"PN-EN 27888:1999 PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999 PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Sewage, water Przewodność elektryczna właściwa w temp. (0 – 80) C  Zakres: (10 – 110000) μS/cm Metoda konduktometryczna Specific Electrical Conductivity at Temperature (0 – 80) °C  Range: (10 – 110,000) μS/cm Method: Conductometric PN-EN 27888:1999 PN-EN 27888:1999 Scieki, woda Sewage, water Przewodnosc elektryczna wlasciwa w temp. (0 – 80) C  Zakres: (10 – 110000) μS/cm Metoda konduktometryczna Specific Electrical Conductivity at Temperature (0 – 80) °C  Range: (10 – 110,000) μS/cm Method: Conductometric PN-EN 27888:1999 PN-EN 27888:1999","categories":["water"],"row_index":280,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage, water Specific Electrical Conductivity at Temperature (0 – 80) °C  Range: (10 – 110,000) μS/cm Method: Conductometric PN-EN 27888:1999 PN-EN 27888:1999"},{"_id":"6a5a55ef9af9f73f38250bb5","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Gleba, grunty Soils, Grounds","test_object_en":"Soils, Grounds","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Sampling for Chemical and Physical Analysis","methodology_en":"Sampling for chemical and physical testing Sampling for Chemical and Physical Analysis","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Sampling for Chemical and Physical Analysis","reference":"PN-ISO 10381-5:2009 PN-ISO 10381-5:2009","norm_bases":["PN-ISO 10381-5:2009 PN-ISO 10381-5:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba, grunty Soils, Grounds Pobieranie próbek do badań chemicznych i fizycznych Sampling for Chemical and Physical Analysis PN-ISO 10381-5:2009 PN-ISO 10381-5:2009 Gleba, grunty Soils, Grounds Pobieranie probek do badan chemicznych i fizycznych Sampling for Chemical and Physical Analysis PN-ISO 10381-5:2009 PN-ISO 10381-5:2009","categories":["environment"],"row_index":281,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soils, Grounds Sampling for chemical and physical testing Sampling for Chemical and Physical Analysis PN-ISO 10381-5:2009 PN-ISO 10381-5:2009"},{"_id":"6a5a55ef9af9f73f38250bb6","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Gleba Soils","test_object_en":"Soils","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Sampling for Chemical and Physical Analysis","methodology_en":"Sampling for chemical and physical testing Sampling for Chemical and Physical Analysis","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Sampling for Chemical and Physical Analysis","reference":"PN-R-04031:1997 PN-R-04031:1997","norm_bases":["PN-R-04031:1997 PN-R-04031:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Soils Pobieranie próbek do badań chemicznych i fizycznych Sampling for Chemical and Physical Analysis PN-R-04031:1997 PN-R-04031:1997 Gleba Soils Pobieranie probek do badan chemicznych i fizycznych Sampling for Chemical and Physical Analysis PN-R-04031:1997 PN-R-04031:1997","categories":["environment"],"row_index":282,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soils Sampling for chemical and physical testing Sampling for Chemical and Physical Analysis PN-R-04031:1997 PN-R-04031:1997"},{"_id":"6a5a55ef9af9f73f38250bb7","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Grunty Grounds","test_object_en":"Grounds","methodology":"Wodoprzepuszczalność - współczynnik filtracji Zakres: (1x10-1 – 1x10-7) m/s (z obliczeń) (0,01 < d < 2,0) mm 20 Zakres: (1x10-5 – 1x10-10) m/s Metoda spadków hydraulicznych Water Permeability – Filtration Coefficient Range: (1 × 10⁻¹ – 1 × 10⁻⁷) m/s (calculated values) Particle size range: 0.01 < d < 2.0 mm 20 Range (1x10-5 – 1x10-10) m/s Hydraulic Gradient Method","methodology_en":"Water Permeability – Filtration Coefficient Range: (1 × 10⁻¹ – 1 × 10⁻⁷) m/s (calculated values) Particle size range: 0.01 < d < 2.0 mm 20 Range (1x10-5 – 1x10-10) m/s Hydraulic Gradient Method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoprzepuszczalność - współczynnik filtracji Zakres: (1x10-1 – 1x10-7) m/s (z obliczeń) (0,01 < d < 2,0) mm 20 Zakres: (1x10-5 – 1x10-10) m/s Metoda spadków hydraulicznych Water Permeability – Filtration Coefficient Range: (1 × 10⁻¹ – 1 × 10⁻⁷) m/s (calculated values) Particle size range: 0.01 < d < 2.0 mm 20 Range (1x10-5 – 1x10-10) m/s Hydraulic Gradient Method","reference":"PN-EN ISO 17892-11:2019-05 z wyłączeniem pkt. 5.2.2.2 i pkt. 5.2.3 SC/ZLGIG/PB.02 1st edition of 01.08.2025 PN-EN ISO 17892-11:2019-05 (excluding clauses 5.2.2.2 and 5.2.3)","norm_bases":["PN-EN ISO 17892-11:2019-05 z wyłączeniem pkt. 5.2.2.2 i pkt. 5.2.3 SC/ZLGIG/PB.02 1st edition of 01.08.2025 PN-EN ISO 17892-11:2019-05 (excluding clauses 5.2.2.2 and 5.2.3)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Grunty Grounds Wodoprzepuszczalność - współczynnik filtracji Zakres: (1x10-1 – 1x10-7) m/s (z obliczeń) (0,01 < d < 2,0) mm 20 Zakres: (1x10-5 – 1x10-10) m/s Metoda spadków hydraulicznych Water Permeability – Filtration Coefficient Range: (1 × 10⁻¹ – 1 × 10⁻⁷) m/s (calculated values) Particle size range: 0.01 < d < 2.0 mm 20 Range (1x10-5 – 1x10-10) m/s Hydraulic Gradient Method PN-EN ISO 17892-11:2019-05 z wyłączeniem pkt. 5.2.2.2 i pkt. 5.2.3 SC/ZLGIG/PB.02 1st edition of 01.08.2025 PN-EN ISO 17892-11:2019-05 (excluding clauses 5.2.2.2 and 5.2.3) Grunty Grounds Wodoprzepuszczalnosc - wspolczynnik filtracji Zakres: (1x10-1 – 1x10-7) m/s (z obliczen) (0,01 < d < 2,0) mm 20 Zakres: (1x10-5 – 1x10-10) m/s Metoda spadkow hydraulicznych Water Permeability – Filtration Coefficient Range: (1 × 10⁻¹ – 1 × 10⁻⁷) m/s (calculated values) Particle size range: 0.01 < d < 2.0 mm 20 Range (1x10-5 – 1x10-10) m/s Hydraulic Gradient Method PN-EN ISO 17892-11:2019-05 z wylaczeniem pkt. 5.2.2.2 i pkt. 5.2.3 SC/ZLGIG/PB.02 1st edition of 01.08.2025 PN-EN ISO 17892-11:2019-05 (excluding clauses 5.2.2.2 and 5.2.3)","categories":["water"],"row_index":283,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Grounds Water Permeability – Filtration Coefficient Range: (1 × 10⁻¹ – 1 × 10⁻⁷) m/s (calculated values) Particle size range: 0.01 < d < 2.0 mm 20 Range (1x10-5 – 1x10-10) m/s Hydraulic Gradient Method PN-EN ISO 17892-11:2019-05 z wyłączeniem pkt. 5.2.2.2 i pkt. 5.2.3 SC/ZLGIG/PB.02 1st edition of 01.08.2025 PN-EN ISO 17892-11:2019-05 (excluding clauses 5.2.2.2 and 5.2.3)"},{"_id":"6a5a55ef9af9f73f38250bb8","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod Waste O): code 01 01 01, 01 01 02, 01 01 80, 01 03 04*, 01 03 05*, 01 03 06, 01 03 07*, 01 03 08, 01 03 09, 01 03 10*, 01 03 80*, 01 03 81, 01 03 99, 01 04 07*, 01 04 08, 01 04 09, 01 04 10, 01 04 11, 01 04 12, 01 04 13, 01 04 80*, 01 04 81, 01 04 82*, 01 04 83, 01 04 84*, 01 04 85, 01 04 99, 03 01 01, 03 01 04*, 03 01 05, 03 01 80*, 03 01 81, 03 01 82, 03 01 99, 03 03 01, 03 03 02, 03 03 05, 03 03 07, 03 03 08, 03 03 09, 03 03 10, 03 03 11, 03 03 80, 03 03 81, 03 03 99, 06 05 02*, 06 05 03, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 13*, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 81, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 11*, 10 02 12, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 02 81, 10 02 99, 10 04 01*, 10 04 02*, 10 04 03*, 10 04 04*, 10 04 05*, 10 04 06*, 10 04 07*, 10 04 09*, 10 04 10, 10 04 99, 10 05 01, 10 05 03*, 10 05 04, 10 05 05*, 10 05 06*, 10 05 08*, 10 05 09, 10 05 10*, 10 05 11, 10 05 80, 10 05 99, 10 06 01, 10 06 02, 10 06 03*, 10 06 04, 10 06 06*, 10 06 07*, 10 06 09*, 10 06 10, 10 06 80, 10 06 99,","test_object_en":"Waste O): code 01 01 01, 01 01 02, 01 01 80, 01 03 04*, 01 03 05*, 01 03 06, 01 03 07*, 01 03 08, 01 03 09, 01 03 10*, 01 03 80*, 01 03 81, 01 03 99, 01 04 07*, 01 04 08, 01 04 09, 01 04 10, 01 04 11, 01 04 12, 01 04 13, 01 04 80*, 01 04 81, 01 04 82*, 01 04 83, 01 04 84*, 01 04 85, 01 04 99, 03 01 01, 03 01 04*, 03 01 05, 03 01 80*, 03 01 81, 03 01 82, 03 01 99, 03 03 01, 03 03 02, 03 03 05, 03 03 07, 03 03 08, 03 03 09, 03 03 10, 03 03 11, 03 03 80, 03 03 81, 03 03 99, 06 05 02*, 06 05 03, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 13*, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 81, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 11*, 10 02 12, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 02 81, 10 02 99, 10 04 01*, 10 04 02*, 10 04 03*, 10 04 04*, 10 04 05*, 10 04 06*, 10 04 07*, 10 04 09*, 10 04 10, 10 04 99, 10 05 01, 10 05 03*, 10 05 04, 10 05 05*, 10 05 06*, 10 05 08*, 10 05 09, 10 05 10*, 10 05 11, 10 05 80, 10 05 99, 10 06 01, 10 06 02, 10 06 03*, 10 06 04, 10 06 06*, 10 06 07*, 10 06 09*, 10 06 10, 10 06 80, 10 06 99,","methodology":"Pobieranie próbek do badań chemicznych i fizycznych, radiochemicznych Sampling for Chemical, Physical, and Radiochemical Analysis","methodology_en":"Sampling for chemical and physical, radiochemical testing Sampling for Chemical, Physical, and Radiochemical Analysis","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych, radiochemicznych Sampling for Chemical, Physical, and Radiochemical Analysis","reference":"SC/ZLGIG/PB.03 edycja 1 z dnia 01.08.2025 SC/ZLGIG/PB.03 1st edition of 01.08.2025","norm_bases":["SC/ZLGIG/PB.03 edycja 1 z dnia 01.08.2025 SC/ZLGIG/PB.03 1st edition of 01.08.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod Waste O): code 01 01 01, 01 01 02, 01 01 80, 01 03 04*, 01 03 05*, 01 03 06, 01 03 07*, 01 03 08, 01 03 09, 01 03 10*, 01 03 80*, 01 03 81, 01 03 99, 01 04 07*, 01 04 08, 01 04 09, 01 04 10, 01 04 11, 01 04 12, 01 04 13, 01 04 80*, 01 04 81, 01 04 82*, 01 04 83, 01 04 84*, 01 04 85, 01 04 99, 03 01 01, 03 01 04*, 03 01 05, 03 01 80*, 03 01 81, 03 01 82, 03 01 99, 03 03 01, 03 03 02, 03 03 05, 03 03 07, 03 03 08, 03 03 09, 03 03 10, 03 03 11, 03 03 80, 03 03 81, 03 03 99, 06 05 02*, 06 05 03, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 13*, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 81, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 11*, 10 02 12, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 02 81, 10 02 99, 10 04 01*, 10 04 02*, 10 04 03*, 10 04 04*, 10 04 05*, 10 04 06*, 10 04 07*, 10 04 09*, 10 04 10, 10 04 99, 10 05 01, 10 05 03*, 10 05 04, 10 05 05*, 10 05 06*, 10 05 08*, 10 05 09, 10 05 10*, 10 05 11, 10 05 80, 10 05 99, 10 06 01, 10 06 02, 10 06 03*, 10 06 04, 10 06 06*, 10 06 07*, 10 06 09*, 10 06 10, 10 06 80, 10 06 99, Pobieranie próbek do badań chemicznych i fizycznych, radiochemicznych Sampling for Chemical, Physical, and Radiochemical Analysis SC/ZLGIG/PB.03 edycja 1 z dnia 01.08.2025 SC/ZLGIG/PB.03 1st edition of 01.08.2025 Odpady O): kod Waste O): code 01 01 01, 01 01 02, 01 01 80, 01 03 04*, 01 03 05*, 01 03 06, 01 03 07*, 01 03 08, 01 03 09, 01 03 10*, 01 03 80*, 01 03 81, 01 03 99, 01 04 07*, 01 04 08, 01 04 09, 01 04 10, 01 04 11, 01 04 12, 01 04 13, 01 04 80*, 01 04 81, 01 04 82*, 01 04 83, 01 04 84*, 01 04 85, 01 04 99, 03 01 01, 03 01 04*, 03 01 05, 03 01 80*, 03 01 81, 03 01 82, 03 01 99, 03 03 01, 03 03 02, 03 03 05, 03 03 07, 03 03 08, 03 03 09, 03 03 10, 03 03 11, 03 03 80, 03 03 81, 03 03 99, 06 05 02*, 06 05 03, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 13*, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 81, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 11*, 10 02 12, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 02 81, 10 02 99, 10 04 01*, 10 04 02*, 10 04 03*, 10 04 04*, 10 04 05*, 10 04 06*, 10 04 07*, 10 04 09*, 10 04 10, 10 04 99, 10 05 01, 10 05 03*, 10 05 04, 10 05 05*, 10 05 06*, 10 05 08*, 10 05 09, 10 05 10*, 10 05 11, 10 05 80, 10 05 99, 10 06 01, 10 06 02, 10 06 03*, 10 06 04, 10 06 06*, 10 06 07*, 10 06 09*, 10 06 10, 10 06 80, 10 06 99, Pobieranie probek do badan chemicznych i fizycznych, radiochemicznych Sampling for Chemical, Physical, and Radiochemical Analysis SC/ZLGIG/PB.03 edycja 1 z dnia 01.08.2025 SC/ZLGIG/PB.03 1st edition of 01.08.2025","categories":["environment"],"row_index":284,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste O): code 01 01 01, 01 01 02, 01 01 80, 01 03 04*, 01 03 05*, 01 03 06, 01 03 07*, 01 03 08, 01 03 09, 01 03 10*, 01 03 80*, 01 03 81, 01 03 99, 01 04 07*, 01 04 08, 01 04 09, 01 04 10, 01 04 11, 01 04 12, 01 04 13, 01 04 80*, 01 04 81, 01 04 82*, 01 04 83, 01 04 84*, 01 04 85, 01 04 99, 03 01 01, 03 01 04*, 03 01 05, 03 01 80*, 03 01 81, 03 01 82, 03 01 99, 03 03 01, 03 03 02, 03 03 05, 03 03 07, 03 03 08, 03 03 09, 03 03 10, 03 03 11, 03 03 80, 03 03 81, 03 03 99, 06 05 02*, 06 05 03, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 03, 10 01 04*, 10 01 05, 10 01 07, 10 01 13*, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 10 01 20*, 10 01 21, 10 01 22*, 10 01 23, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 81, 10 01 82, 10 01 99, 10 02 01, 10 02 02, 10 02 07*, 10 02 08, 10 02 10, 10 02 11*, 10 02 12, 10 02 13*, 10 02 14, 10 02 15, 10 02 80, 10 02 81, 10 02 99, 10 04 01*, 10 04 02*, 10 04 03*, 10 04 04*, 10 04 05*, 10 04 06*, 10 04 07*, 10 04 09*, 10 04 10, 10 04 99, 10 05 01, 10 05 03*, 10 05 04, 10 05 05*, 10 05 06*, 10 05 08*, 10 05 09, 10 05 10*, 10 05 11, 10 05 80, 10 05 99, 10 06 01, 10 06 02, 10 06 03*, 10 06 04, 10 06 06*, 10 06 07*, 10 06 09*, 10 06 10, 10 06 80, 10 06 99, Sampling for chemical and physical, radiochemical testing Sampling for Chemical, Physical, and Radiochemical Analysis SC/ZLGIG/PB.03 edycja 1 z dnia 01.08.2025 SC/ZLGIG/PB.03 1st edition of 01.08.2025"},{"_id":"6a5a55ef9af9f73f38250bb9","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"10 08 04, 10 08 08*, 10 08 09, 10 08 10*, 10 08 11, 10 08 12* 10 08 13, 10 08 14, 10 08 15*, 10 08 16, 10 08 17*, 10 08 18, 10 08 19*, 10 08 20, 10 08 99, 17 01 01, 17 01 02, 17 01 03, 17 01 06*, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 02 01, 17 02 03, 17 02 04*, 17 03 01*, 17 03 02, 17 03 03*, 17 03 80, 17 05 03*, 17 05 04, 17 05 05*, 17 05 06, 17 05 07*, 17 05 08, 17 08 01*, 17 08 02, 17 09 01*, 17 09 02*, 17 09 03*, 17 09 04, 19 01 02, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 10*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 01 15*, 19 01 16, 19 01 17*, 19 01 18, 19 01 19, 19 01 99, 19 02 03, 19 02 04*, 19 02 05*, 19 02 06, 19 02 07*, 19 02 08*, 19 02 09*, 19 02 10, 19 02 11*, 19 02 99, 19 03 04*, 19 03 05, 19 03 06*, 19 03 07, 19 03 08*, 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 05, 19 08 06*, 19 08 07*, 19 08 08*, 19 08 09, 19 08 10*, 19 08 11*, 19 08 12, 19 08 13*, 19 08 14, 19 08 99, 19 09 01, 19 09 02, 19 09 03, 19 09 04, 19 09 05, 19 09 06, 19 09 99, 19 12 01, 19 12 02, 19 12 03, 19 12 04, 19 12 06*, 19 12 07, 19 12 08, 19 12 09, 19 12 10, 19 12 11*, 19 12 12, 19 13 01*, 19 13 02, 19 13 03*, 19 13 04, 19 13 05*, 19 13 06, 19 13 07*, 19 13 08, 20 03 03, 20 03 04, 20 03 06","test_object_en":"10 08 04, 10 08 08*, 10 08 09, 10 08 10*, 10 08 11, 10 08 12* 10 08 13, 10 08 14, 10 08 15*, 10 08 16, 10 08 17*, 10 08 18, 10 08 19*, 10 08 20, 10 08 99, 17 01 01, 17 01 02, 17 01 03, 17 01 06*, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 02 01, 17 02 03, 17 02 04*, 17 03 01*, 17 03 02, 17 03 03*, 17 03 80, 17 05 03*, 17 05 04, 17 05 05*, 17 05 06, 17 05 07*, 17 05 08, 17 08 01*, 17 08 02, 17 09 01*, 17 09 02*, 17 09 03*, 17 09 04, 19 01 02, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 10*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 01 15*, 19 01 16, 19 01 17*, 19 01 18, 19 01 19, 19 01 99, 19 02 03, 19 02 04*, 19 02 05*, 19 02 06, 19 02 07*, 19 02 08*, 19 02 09*, 19 02 10, 19 02 11*, 19 02 99, 19 03 04*, 19 03 05, 19 03 06*, 19 03 07, 19 03 08*, 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 05, 19 08 06*, 19 08 07*, 19 08 08*, 19 08 09, 19 08 10*, 19 08 11*, 19 08 12, 19 08 13*, 19 08 14, 19 08 99, 19 09 01, 19 09 02, 19 09 03, 19 09 04, 19 09 05, 19 09 06, 19 09 99, 19 12 01, 19 12 02, 19 12 03, 19 12 04, 19 12 06*, 19 12 07, 19 12 08, 19 12 09, 19 12 10, 19 12 11*, 19 12 12, 19 13 01*, 19 13 02, 19 13 03*, 19 13 04, 19 13 05*, 19 13 06, 19 13 07*, 19 13 08, 20 03 03, 20 03 04, 20 03 06","methodology":"Pobieranie próbek do badań chemicznych i fizycznych, radiochemicznych Sampling for Chemical, Physical, and Radiochemical Analysis","methodology_en":"Sampling for chemical and physical, radiochemical testing Sampling for Chemical, Physical, and Radiochemical Analysis","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych, radiochemicznych Sampling for Chemical, Physical, and Radiochemical Analysis","reference":"SC/ZLGIG/PB.03 edycja 1 z dnia 01.08.2025 SC/ZLGIG/PB.03 1st edition of 01.08.2025","norm_bases":["SC/ZLGIG/PB.03 edycja 1 z dnia 01.08.2025 SC/ZLGIG/PB.03 1st edition of 01.08.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"10 08 04, 10 08 08*, 10 08 09, 10 08 10*, 10 08 11, 10 08 12* 10 08 13, 10 08 14, 10 08 15*, 10 08 16, 10 08 17*, 10 08 18, 10 08 19*, 10 08 20, 10 08 99, 17 01 01, 17 01 02, 17 01 03, 17 01 06*, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 02 01, 17 02 03, 17 02 04*, 17 03 01*, 17 03 02, 17 03 03*, 17 03 80, 17 05 03*, 17 05 04, 17 05 05*, 17 05 06, 17 05 07*, 17 05 08, 17 08 01*, 17 08 02, 17 09 01*, 17 09 02*, 17 09 03*, 17 09 04, 19 01 02, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 10*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 01 15*, 19 01 16, 19 01 17*, 19 01 18, 19 01 19, 19 01 99, 19 02 03, 19 02 04*, 19 02 05*, 19 02 06, 19 02 07*, 19 02 08*, 19 02 09*, 19 02 10, 19 02 11*, 19 02 99, 19 03 04*, 19 03 05, 19 03 06*, 19 03 07, 19 03 08*, 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 05, 19 08 06*, 19 08 07*, 19 08 08*, 19 08 09, 19 08 10*, 19 08 11*, 19 08 12, 19 08 13*, 19 08 14, 19 08 99, 19 09 01, 19 09 02, 19 09 03, 19 09 04, 19 09 05, 19 09 06, 19 09 99, 19 12 01, 19 12 02, 19 12 03, 19 12 04, 19 12 06*, 19 12 07, 19 12 08, 19 12 09, 19 12 10, 19 12 11*, 19 12 12, 19 13 01*, 19 13 02, 19 13 03*, 19 13 04, 19 13 05*, 19 13 06, 19 13 07*, 19 13 08, 20 03 03, 20 03 04, 20 03 06 Pobieranie próbek do badań chemicznych i fizycznych, radiochemicznych Sampling for Chemical, Physical, and Radiochemical Analysis SC/ZLGIG/PB.03 edycja 1 z dnia 01.08.2025 SC/ZLGIG/PB.03 1st edition of 01.08.2025 10 08 04, 10 08 08*, 10 08 09, 10 08 10*, 10 08 11, 10 08 12* 10 08 13, 10 08 14, 10 08 15*, 10 08 16, 10 08 17*, 10 08 18, 10 08 19*, 10 08 20, 10 08 99, 17 01 01, 17 01 02, 17 01 03, 17 01 06*, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 02 01, 17 02 03, 17 02 04*, 17 03 01*, 17 03 02, 17 03 03*, 17 03 80, 17 05 03*, 17 05 04, 17 05 05*, 17 05 06, 17 05 07*, 17 05 08, 17 08 01*, 17 08 02, 17 09 01*, 17 09 02*, 17 09 03*, 17 09 04, 19 01 02, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 10*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 01 15*, 19 01 16, 19 01 17*, 19 01 18, 19 01 19, 19 01 99, 19 02 03, 19 02 04*, 19 02 05*, 19 02 06, 19 02 07*, 19 02 08*, 19 02 09*, 19 02 10, 19 02 11*, 19 02 99, 19 03 04*, 19 03 05, 19 03 06*, 19 03 07, 19 03 08*, 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 05, 19 08 06*, 19 08 07*, 19 08 08*, 19 08 09, 19 08 10*, 19 08 11*, 19 08 12, 19 08 13*, 19 08 14, 19 08 99, 19 09 01, 19 09 02, 19 09 03, 19 09 04, 19 09 05, 19 09 06, 19 09 99, 19 12 01, 19 12 02, 19 12 03, 19 12 04, 19 12 06*, 19 12 07, 19 12 08, 19 12 09, 19 12 10, 19 12 11*, 19 12 12, 19 13 01*, 19 13 02, 19 13 03*, 19 13 04, 19 13 05*, 19 13 06, 19 13 07*, 19 13 08, 20 03 03, 20 03 04, 20 03 06 Pobieranie probek do badan chemicznych i fizycznych, radiochemicznych Sampling for Chemical, Physical, and Radiochemical Analysis SC/ZLGIG/PB.03 edycja 1 z dnia 01.08.2025 SC/ZLGIG/PB.03 1st edition of 01.08.2025","categories":["other"],"row_index":285,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"10 08 04, 10 08 08*, 10 08 09, 10 08 10*, 10 08 11, 10 08 12* 10 08 13, 10 08 14, 10 08 15*, 10 08 16, 10 08 17*, 10 08 18, 10 08 19*, 10 08 20, 10 08 99, 17 01 01, 17 01 02, 17 01 03, 17 01 06*, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 02 01, 17 02 03, 17 02 04*, 17 03 01*, 17 03 02, 17 03 03*, 17 03 80, 17 05 03*, 17 05 04, 17 05 05*, 17 05 06, 17 05 07*, 17 05 08, 17 08 01*, 17 08 02, 17 09 01*, 17 09 02*, 17 09 03*, 17 09 04, 19 01 02, 19 01 05*, 19 01 06*, 19 01 07*, 19 01 10*, 19 01 11*, 19 01 12, 19 01 13*, 19 01 14, 19 01 15*, 19 01 16, 19 01 17*, 19 01 18, 19 01 19, 19 01 99, 19 02 03, 19 02 04*, 19 02 05*, 19 02 06, 19 02 07*, 19 02 08*, 19 02 09*, 19 02 10, 19 02 11*, 19 02 99, 19 03 04*, 19 03 05, 19 03 06*, 19 03 07, 19 03 08*, 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 05, 19 08 06*, 19 08 07*, 19 08 08*, 19 08 09, 19 08 10*, 19 08 11*, 19 08 12, 19 08 13*, 19 08 14, 19 08 99, 19 09 01, 19 09 02, 19 09 03, 19 09 04, 19 09 05, 19 09 06, 19 09 99, 19 12 01, 19 12 02, 19 12 03, 19 12 04, 19 12 06*, 19 12 07, 19 12 08, 19 12 09, 19 12 10, 19 12 11*, 19 12 12, 19 13 01*, 19 13 02, 19 13 03*, 19 13 04, 19 13 05*, 19 13 06, 19 13 07*, 19 13 08, 20 03 03, 20 03 04, 20 03 06 Sampling for chemical and physical, radiochemical testing Sampling for Chemical, Physical, and Radiochemical Analysis SC/ZLGIG/PB.03 edycja 1 z dnia 01.08.2025 SC/ZLGIG/PB.03 1st edition of 01.08.2025"},{"_id":"6a5a55ef9af9f73f38250bba","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda Water","test_object_en":"Water","methodology":"Stężenie pierwiastków Zakres: Fe (0,0005 – 1000) mg/l (0,00002 – 35,8) mmol/l r Mn (0,0002 – 1000) mg/l (0,000008 – 36,4) mmol/l r Cd (0,0005 – 10,0) mg/l Be, Cr, Ti, V (0,0005 – 10,0) mg/l Co, Zr (0,0010 – 10,0) mg/l Cu, Mo, Ni (0,0020 – 10,0) mg/l Sb (0,0050 – 10,0) mg/l Ag, As, Pb, Se, Sn (0,0050 – 10,0) mg/l B, Zn (0,0050 – 200) mg/l Al (0,010 – 200) mg/l Ba (0,0002 – 2000) mg/l (0,000003 – 29,1) mmol/l r Sr (0,0002 – 1000) mg/l (0,000005 – 22,8) mmol/l r Li (0,0010 – 1000) mg/l (0,00015 – 144) mmol/l Ca (0,0010 – 1000) mmol/l r (0,020 – 20000) mg/l Mg (0,0010 – 1000) mmol/l r (0,012 – 12200) mg/l Na (0,0010 – 5000) mmol/l (0,023 – 115000) mg/l K (0,0010 – 1000) mmol/l (0,039 – 39100) mg/l S (0,05 – 5000) mg/l SO 2- og 4 (0,001 – 104) mmol/l SO 2- r 4 (0,017 – 1670) mg/l S Si (0,050 – 100) mg/l SiO 2- og 3 (0,0013 – 2,63) mmol/l SiO 2- r 3 (0,040 – 79,0) mg/l SiO 2 (0,020 – 36,9) mg/l Si P (0,030 – 1000) mg/l PO 3- og 4 (0,0010 – 31,6) mmol/l PO 3- r 4 (0,0098 – 326) mg/l P (0,022 – 747) mg/l P O 2 5 La, Tl (0,0050 - 10,0) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","methodology_en":"Element concentrations Range: Fe (0,0005 – 1000) mg/l (0,00002 – 35,8) mmol/l r Mn (0,0002 – 1000) mg/l (0,000008 – 36,4) mmol/l r Cd (0,0005 – 10,0) mg/l Be, Cr, Ti, V (0,0005 – 10,0) mg/l Co, Zr (0,0010 – 10,0) mg/l Cu, Mo, Ni (0,0020 – 10,0) mg/l Sb (0,0050 – 10,0) mg/l Ag, As, Pb, Se, Sn (0,0050 – 10,0) mg/l B, Zn (0,0050 – 200) mg/l Al (0,010 – 200) mg/l Ba (0,0002 – 2000) mg/l (0,000003 – 29,1) mmol/l r Sr (0,0002 – 1000) mg/l (0,000005 – 22,8) mmol/l r Li (0,0010 – 1000) mg/l (0,00015 – 144) mmol/l Ca (0,0010 – 1000) mmol/l r (0,020 – 20000) mg/l Mg (0,0010 – 1000) mmol/l r (0,012 – 12200) mg/l Na (0,0010 – 5000) mmol/l (0,023 – 115000) mg/l K (0,0010 – 1000) mmol/l (0,039 – 39100) mg/l S (0,05 – 5000) mg/l SO 2- tot. 4 (0,001 – 104) mmol/l SO 2- r 4 (0,017 – 1670) mg/l S Si (0,050 – 100) mg/l SiO 2- tot. 3 (0,0013 – 2,63) mmol/l SiO 2- r 3 (0,040 – 79,0) mg/l SiO 2 (0,020 – 36,9) mg/l Si P (0,030 – 1000) mg/l PO 3- tot. 4 (0,0010 – 31,6) mmol/l PO 3- r 4 (0,0098 – 326) mg/l P (0,022 – 747) mg/l P O 2 5 La, Tl (0,0050 - 10,0) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pierwiastków Zakres: Fe (0,0005 – 1000) mg/l (0,00002 – 35,8) mmol/l r Mn (0,0002 – 1000) mg/l (0,000008 – 36,4) mmol/l r Cd (0,0005 – 10,0) mg/l Be, Cr, Ti, V (0,0005 – 10,0) mg/l Co, Zr (0,0010 – 10,0) mg/l Cu, Mo, Ni (0,0020 – 10,0) mg/l Sb (0,0050 – 10,0) mg/l Ag, As, Pb, Se, Sn (0,0050 – 10,0) mg/l B, Zn (0,0050 – 200) mg/l Al (0,010 – 200) mg/l Ba (0,0002 – 2000) mg/l (0,000003 – 29,1) mmol/l r Sr (0,0002 – 1000) mg/l (0,000005 – 22,8) mmol/l r Li (0,0010 – 1000) mg/l (0,00015 – 144) mmol/l Ca (0,0010 – 1000) mmol/l r (0,020 – 20000) mg/l Mg (0,0010 – 1000) mmol/l r (0,012 – 12200) mg/l Na (0,0010 – 5000) mmol/l (0,023 – 115000) mg/l K (0,0010 – 1000) mmol/l (0,039 – 39100) mg/l S (0,05 – 5000) mg/l SO 2- og 4 (0,001 – 104) mmol/l SO 2- r 4 (0,017 – 1670) mg/l S Si (0,050 – 100) mg/l SiO 2- og 3 (0,0013 – 2,63) mmol/l SiO 2- r 3 (0,040 – 79,0) mg/l SiO 2 (0,020 – 36,9) mg/l Si P (0,030 – 1000) mg/l PO 3- og 4 (0,0010 – 31,6) mmol/l PO 3- r 4 (0,0098 – 326) mg/l P (0,022 – 747) mg/l P O 2 5 La, Tl (0,0050 - 10,0) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1 z dn. 01.08.2025","norm_bases":["PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1 z dn. 01.08.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Water Stężenie pierwiastków Zakres: Fe (0,0005 – 1000) mg/l (0,00002 – 35,8) mmol/l r Mn (0,0002 – 1000) mg/l (0,000008 – 36,4) mmol/l r Cd (0,0005 – 10,0) mg/l Be, Cr, Ti, V (0,0005 – 10,0) mg/l Co, Zr (0,0010 – 10,0) mg/l Cu, Mo, Ni (0,0020 – 10,0) mg/l Sb (0,0050 – 10,0) mg/l Ag, As, Pb, Se, Sn (0,0050 – 10,0) mg/l B, Zn (0,0050 – 200) mg/l Al (0,010 – 200) mg/l Ba (0,0002 – 2000) mg/l (0,000003 – 29,1) mmol/l r Sr (0,0002 – 1000) mg/l (0,000005 – 22,8) mmol/l r Li (0,0010 – 1000) mg/l (0,00015 – 144) mmol/l Ca (0,0010 – 1000) mmol/l r (0,020 – 20000) mg/l Mg (0,0010 – 1000) mmol/l r (0,012 – 12200) mg/l Na (0,0010 – 5000) mmol/l (0,023 – 115000) mg/l K (0,0010 – 1000) mmol/l (0,039 – 39100) mg/l S (0,05 – 5000) mg/l SO 2- og 4 (0,001 – 104) mmol/l SO 2- r 4 (0,017 – 1670) mg/l S Si (0,050 – 100) mg/l SiO 2- og 3 (0,0013 – 2,63) mmol/l SiO 2- r 3 (0,040 – 79,0) mg/l SiO 2 (0,020 – 36,9) mg/l Si P (0,030 – 1000) mg/l PO 3- og 4 (0,0010 – 31,6) mmol/l PO 3- r 4 (0,0098 – 326) mg/l P (0,022 – 747) mg/l P O 2 5 La, Tl (0,0050 - 10,0) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1 z dn. 01.08.2025 Woda Water Stezenie pierwiastkow Zakres: Fe (0,0005 – 1000) mg/l (0,00002 – 35,8) mmol/l r Mn (0,0002 – 1000) mg/l (0,000008 – 36,4) mmol/l r Cd (0,0005 – 10,0) mg/l Be, Cr, Ti, V (0,0005 – 10,0) mg/l Co, Zr (0,0010 – 10,0) mg/l Cu, Mo, Ni (0,0020 – 10,0) mg/l Sb (0,0050 – 10,0) mg/l Ag, As, Pb, Se, Sn (0,0050 – 10,0) mg/l B, Zn (0,0050 – 200) mg/l Al (0,010 – 200) mg/l Ba (0,0002 – 2000) mg/l (0,000003 – 29,1) mmol/l r Sr (0,0002 – 1000) mg/l (0,000005 – 22,8) mmol/l r Li (0,0010 – 1000) mg/l (0,00015 – 144) mmol/l Ca (0,0010 – 1000) mmol/l r (0,020 – 20000) mg/l Mg (0,0010 – 1000) mmol/l r (0,012 – 12200) mg/l Na (0,0010 – 5000) mmol/l (0,023 – 115000) mg/l K (0,0010 – 1000) mmol/l (0,039 – 39100) mg/l S (0,05 – 5000) mg/l SO 2- og 4 (0,001 – 104) mmol/l SO 2- r 4 (0,017 – 1670) mg/l S Si (0,050 – 100) mg/l SiO 2- og 3 (0,0013 – 2,63) mmol/l SiO 2- r 3 (0,040 – 79,0) mg/l SiO 2 (0,020 – 36,9) mg/l Si P (0,030 – 1000) mg/l PO 3- og 4 (0,0010 – 31,6) mmol/l PO 3- r 4 (0,0098 – 326) mg/l P (0,022 – 747) mg/l P O 2 5 La, Tl (0,0050 - 10,0) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1 z dn. 01.08.2025","categories":["water"],"row_index":286,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Element concentrations Range: Fe (0,0005 – 1000) mg/l (0,00002 – 35,8) mmol/l r Mn (0,0002 – 1000) mg/l (0,000008 – 36,4) mmol/l r Cd (0,0005 – 10,0) mg/l Be, Cr, Ti, V (0,0005 – 10,0) mg/l Co, Zr (0,0010 – 10,0) mg/l Cu, Mo, Ni (0,0020 – 10,0) mg/l Sb (0,0050 – 10,0) mg/l Ag, As, Pb, Se, Sn (0,0050 – 10,0) mg/l B, Zn (0,0050 – 200) mg/l Al (0,010 – 200) mg/l Ba (0,0002 – 2000) mg/l (0,000003 – 29,1) mmol/l r Sr (0,0002 – 1000) mg/l (0,000005 – 22,8) mmol/l r Li (0,0010 – 1000) mg/l (0,00015 – 144) mmol/l Ca (0,0010 – 1000) mmol/l r (0,020 – 20000) mg/l Mg (0,0010 – 1000) mmol/l r (0,012 – 12200) mg/l Na (0,0010 – 5000) mmol/l (0,023 – 115000) mg/l K (0,0010 – 1000) mmol/l (0,039 – 39100) mg/l S (0,05 – 5000) mg/l SO 2- tot. 4 (0,001 – 104) mmol/l SO 2- r 4 (0,017 – 1670) mg/l S Si (0,050 – 100) mg/l SiO 2- tot. 3 (0,0013 – 2,63) mmol/l SiO 2- r 3 (0,040 – 79,0) mg/l SiO 2 (0,020 – 36,9) mg/l Si P (0,030 – 1000) mg/l PO 3- tot. 4 (0,0010 – 31,6) mmol/l PO 3- r 4 (0,0098 – 326) mg/l P (0,022 – 747) mg/l P O 2 5 La, Tl (0,0050 - 10,0) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1 z dn. 01.08.2025","search_zh":"水 Water PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1 z dn. 01.08.2025","test_object_zh":"水 Water"},{"_id":"6a5a55ef9af9f73f38250bbb","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda Water","test_object_en":"Water","methodology":"Elements concentration Range: Fe (0,0005 – 1000) mg/l (0,00002 – 35,8) mmol/l r Mn (0,0002 – 1000) mg/l (0,000008 – 36,4) mmol/l r Cd (0,0005 – 10,0) mg/l Be, Cr, Ti, V (0,0005 – 10,0) mg/l Co, Zr (0,0010 – 10,0) mg/l Cu, Mo, Ni (0,0020 – 10,0) mg/l Sb (0,0050 – 10,0) mg/l Ag, As, Pb, Se, Sn (0,0050 – 10,0) mg/l B, Zn (0,0050 – 200) mg/l Al (0,010 – 200) mg/l Ba (0,0002 – 2000) mg/l (0,000003 – 29,1) mmol/l r Sr (0,0002 – 1000) mg/l (0,000005 – 22,8) mmol/l r Li (0,0010 – 1000) mg/l (0,00015 – 144) mmol/l Ca (0,0010 – 1000) mmol/l r (0,020 – 20000) mg/l Mg (0,0010 – 1000) mmol/l r (0,012 – 12200) mg/l Na (0,0010 – 5000) mmol/l (0,023 – 115000) mg/l K (0,0010 – 1000) mmol/l (0,039 – 39100) mg/l S (0,05 – 5000) mg/l SO 2- tot. 4 (0,001 – 104) mmol/l SO 2- r 4 (0,017 – 1670) mg/l S Si (0,050 – 100) mg/l SiO 2- tot. 3 (0,0013 – 2,63) mmol/l SiO 2- r 3 (0,040 – 79,0) mg/l SiO 2 (0,020 – 36,9) mg/l Si P (0,030 – 1000) mg/l PO 3- tot. 4 (0,0010 – 31,6) mmol/l PO 3- r 4 (0,0098 – 326) mg/l P (0,022 – 747) mg/l P O 2 5 La, Tl (0,0050 – 10,0) mg/l Inductively coupled plasma optical emission spectrometry method (ICP-OES)","methodology_en":"Elements concentration Range: Fe (0,0005 – 1000) mg/l (0,00002 – 35,8) mmol/l r Mn (0,0002 – 1000) mg/l (0,000008 – 36,4) mmol/l r Cd (0,0005 – 10,0) mg/l Be, Cr, Ti, V (0,0005 – 10,0) mg/l Co, Zr (0,0010 – 10,0) mg/l Cu, Mo, Ni (0,0020 – 10,0) mg/l Sb (0,0050 – 10,0) mg/l Ag, As, Pb, Se, Sn (0,0050 – 10,0) mg/l B, Zn (0,0050 – 200) mg/l Al (0,010 – 200) mg/l Ba (0,0002 – 2000) mg/l (0,000003 – 29,1) mmol/l r Sr (0,0002 – 1000) mg/l (0,000005 – 22,8) mmol/l r Li (0,0010 – 1000) mg/l (0,00015 – 144) mmol/l Ca (0,0010 – 1000) mmol/l r (0,020 – 20000) mg/l Mg (0,0010 – 1000) mmol/l r (0,012 – 12200) mg/l Na (0,0010 – 5000) mmol/l (0,023 – 115000) mg/l K (0,0010 – 1000) mmol/l (0,039 – 39100) mg/l S (0,05 – 5000) mg/l SO 2- tot. 4 (0,001 – 104) mmol/l SO 2- r 4 (0,017 – 1670) mg/l S Si (0,050 – 100) mg/l SiO 2- tot. 3 (0,0013 – 2,63) mmol/l SiO 2- r 3 (0,040 – 79,0) mg/l SiO 2 (0,020 – 36,9) mg/l Si P (0,030 – 1000) mg/l PO 3- tot. 4 (0,0010 – 31,6) mmol/l PO 3- r 4 (0,0098 – 326) mg/l P (0,022 – 747) mg/l P O 2 5 La, Tl (0,0050 – 10,0) mg/l Inductively coupled plasma optical emission spectrometry method (ICP-OES)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Elements concentration Range: Fe (0,0005 – 1000) mg/l (0,00002 – 35,8) mmol/l r Mn (0,0002 – 1000) mg/l (0,000008 – 36,4) mmol/l r Cd (0,0005 – 10,0) mg/l Be, Cr, Ti, V (0,0005 – 10,0) mg/l Co, Zr (0,0010 – 10,0) mg/l Cu, Mo, Ni (0,0020 – 10,0) mg/l Sb (0,0050 – 10,0) mg/l Ag, As, Pb, Se, Sn (0,0050 – 10,0) mg/l B, Zn (0,0050 – 200) mg/l Al (0,010 – 200) mg/l Ba (0,0002 – 2000) mg/l (0,000003 – 29,1) mmol/l r Sr (0,0002 – 1000) mg/l (0,000005 – 22,8) mmol/l r Li (0,0010 – 1000) mg/l (0,00015 – 144) mmol/l Ca (0,0010 – 1000) mmol/l r (0,020 – 20000) mg/l Mg (0,0010 – 1000) mmol/l r (0,012 – 12200) mg/l Na (0,0010 – 5000) mmol/l (0,023 – 115000) mg/l K (0,0010 – 1000) mmol/l (0,039 – 39100) mg/l S (0,05 – 5000) mg/l SO 2- tot. 4 (0,001 – 104) mmol/l SO 2- r 4 (0,017 – 1670) mg/l S Si (0,050 – 100) mg/l SiO 2- tot. 3 (0,0013 – 2,63) mmol/l SiO 2- r 3 (0,040 – 79,0) mg/l SiO 2 (0,020 – 36,9) mg/l Si P (0,030 – 1000) mg/l PO 3- tot. 4 (0,0010 – 31,6) mmol/l PO 3- r 4 (0,0098 – 326) mg/l P (0,022 – 747) mg/l P O 2 5 La, Tl (0,0050 – 10,0) mg/l Inductively coupled plasma optical emission spectrometry method (ICP-OES)","reference":"PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1st of 01/08/2025","norm_bases":["PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Water Elements concentration Range: Fe (0,0005 – 1000) mg/l (0,00002 – 35,8) mmol/l r Mn (0,0002 – 1000) mg/l (0,000008 – 36,4) mmol/l r Cd (0,0005 – 10,0) mg/l Be, Cr, Ti, V (0,0005 – 10,0) mg/l Co, Zr (0,0010 – 10,0) mg/l Cu, Mo, Ni (0,0020 – 10,0) mg/l Sb (0,0050 – 10,0) mg/l Ag, As, Pb, Se, Sn (0,0050 – 10,0) mg/l B, Zn (0,0050 – 200) mg/l Al (0,010 – 200) mg/l Ba (0,0002 – 2000) mg/l (0,000003 – 29,1) mmol/l r Sr (0,0002 – 1000) mg/l (0,000005 – 22,8) mmol/l r Li (0,0010 – 1000) mg/l (0,00015 – 144) mmol/l Ca (0,0010 – 1000) mmol/l r (0,020 – 20000) mg/l Mg (0,0010 – 1000) mmol/l r (0,012 – 12200) mg/l Na (0,0010 – 5000) mmol/l (0,023 – 115000) mg/l K (0,0010 – 1000) mmol/l (0,039 – 39100) mg/l S (0,05 – 5000) mg/l SO 2- tot. 4 (0,001 – 104) mmol/l SO 2- r 4 (0,017 – 1670) mg/l S Si (0,050 – 100) mg/l SiO 2- tot. 3 (0,0013 – 2,63) mmol/l SiO 2- r 3 (0,040 – 79,0) mg/l SiO 2 (0,020 – 36,9) mg/l Si P (0,030 – 1000) mg/l PO 3- tot. 4 (0,0010 – 31,6) mmol/l PO 3- r 4 (0,0098 – 326) mg/l P (0,022 – 747) mg/l P O 2 5 La, Tl (0,0050 – 10,0) mg/l Inductively coupled plasma optical emission spectrometry method (ICP-OES) PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1st of 01/08/2025 Woda Water Elements concentration Range: Fe (0,0005 – 1000) mg/l (0,00002 – 35,8) mmol/l r Mn (0,0002 – 1000) mg/l (0,000008 – 36,4) mmol/l r Cd (0,0005 – 10,0) mg/l Be, Cr, Ti, V (0,0005 – 10,0) mg/l Co, Zr (0,0010 – 10,0) mg/l Cu, Mo, Ni (0,0020 – 10,0) mg/l Sb (0,0050 – 10,0) mg/l Ag, As, Pb, Se, Sn (0,0050 – 10,0) mg/l B, Zn (0,0050 – 200) mg/l Al (0,010 – 200) mg/l Ba (0,0002 – 2000) mg/l (0,000003 – 29,1) mmol/l r Sr (0,0002 – 1000) mg/l (0,000005 – 22,8) mmol/l r Li (0,0010 – 1000) mg/l (0,00015 – 144) mmol/l Ca (0,0010 – 1000) mmol/l r (0,020 – 20000) mg/l Mg (0,0010 – 1000) mmol/l r (0,012 – 12200) mg/l Na (0,0010 – 5000) mmol/l (0,023 – 115000) mg/l K (0,0010 – 1000) mmol/l (0,039 – 39100) mg/l S (0,05 – 5000) mg/l SO 2- tot. 4 (0,001 – 104) mmol/l SO 2- r 4 (0,017 – 1670) mg/l S Si (0,050 – 100) mg/l SiO 2- tot. 3 (0,0013 – 2,63) mmol/l SiO 2- r 3 (0,040 – 79,0) mg/l SiO 2 (0,020 – 36,9) mg/l Si P (0,030 – 1000) mg/l PO 3- tot. 4 (0,0010 – 31,6) mmol/l PO 3- r 4 (0,0098 – 326) mg/l P (0,022 – 747) mg/l P O 2 5 La, Tl (0,0050 – 10,0) mg/l Inductively coupled plasma optical emission spectrometry method (ICP-OES) PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1st of 01/08/2025","categories":["water","environment"],"row_index":287,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Elements concentration Range: Fe (0,0005 – 1000) mg/l (0,00002 – 35,8) mmol/l r Mn (0,0002 – 1000) mg/l (0,000008 – 36,4) mmol/l r Cd (0,0005 – 10,0) mg/l Be, Cr, Ti, V (0,0005 – 10,0) mg/l Co, Zr (0,0010 – 10,0) mg/l Cu, Mo, Ni (0,0020 – 10,0) mg/l Sb (0,0050 – 10,0) mg/l Ag, As, Pb, Se, Sn (0,0050 – 10,0) mg/l B, Zn (0,0050 – 200) mg/l Al (0,010 – 200) mg/l Ba (0,0002 – 2000) mg/l (0,000003 – 29,1) mmol/l r Sr (0,0002 – 1000) mg/l (0,000005 – 22,8) mmol/l r Li (0,0010 – 1000) mg/l (0,00015 – 144) mmol/l Ca (0,0010 – 1000) mmol/l r (0,020 – 20000) mg/l Mg (0,0010 – 1000) mmol/l r (0,012 – 12200) mg/l Na (0,0010 – 5000) mmol/l (0,023 – 115000) mg/l K (0,0010 – 1000) mmol/l (0,039 – 39100) mg/l S (0,05 – 5000) mg/l SO 2- tot. 4 (0,001 – 104) mmol/l SO 2- r 4 (0,017 – 1670) mg/l S Si (0,050 – 100) mg/l SiO 2- tot. 3 (0,0013 – 2,63) mmol/l SiO 2- r 3 (0,040 – 79,0) mg/l SiO 2 (0,020 – 36,9) mg/l Si P (0,030 – 1000) mg/l PO 3- tot. 4 (0,0010 – 31,6) mmol/l PO 3- r 4 (0,0098 – 326) mg/l P (0,022 – 747) mg/l P O 2 5 La, Tl (0,0050 – 10,0) mg/l Inductively coupled plasma optical emission spectrometry method (ICP-OES) PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1st of 01/08/2025","search_zh":"水 Water PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1st of 01/08/2025","test_object_zh":"水 Water"},{"_id":"6a5a55ef9af9f73f38250bbc","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Ścieki Sewage","test_object_en":"Sewage","methodology":"Stężenie pierwiastków Zakres: Fe (0,0050 – 1000) mg/l (0,0002 – 35,8) mmol/l r Mn (0,0050 – 1000) mg/l (0,0002 – 36,4) mmol/l r Cd (0,0010 – 1000) mg/l Be (0,0010 – 1000) mg/l Cr, Ti, V (0,0050 – 1000) mg/l Co, Zr (0,0050 – 1000) mg/l Mo (0,0050 – 1000) mg/l Cu,Ni (0,010 – 1000) mg/l Sb (0,050 – 100) mg/l Ag (0,020 – 100) mg/l As (0,050 – 100) mg/l B (0,050 – 1000) mg/l Zn (0,050 – 1000) mg/l Pb (0,020 – 100) mg/l Se, Sn (0,050 – 100) mg/l Al (0,10 – 1000) mg/l Bi (0,10 – 100) mg/l Ba (0,020 – 2000) mg/l (0,0003 – 29,1) mmol/l r Sr (0,020 – 1000) mg/l (0,0005 – 22,8) mmol/l r Li (0,10 – 1000) mg/l (0,015 – 144) mmol/l Ca (0,050 – 1000) mmol/l r (1,00 – 20000) mg/l Mg (0,050 – 1000) mmol/l r (0,60 – 12200) mg/l Na (0,050 – 5000) mmol/l (1,15 – 115000) mg/l K (0,050 – 1000) mmol/l (1,95 – 39100) mg/l S (5,00 – 3000) mg/l SO 2- og 4 (0,10 – 62,5 ) mmol/l SO 2- r 4 (1,70 – 999) mg/l S Si (0,50 – 100) mg/l SiO 2- og 3 (0,013 – 2,63) mmol/l SiO 2- r 3 (0,40 – 79,0) mg/l SiO 2 (0,19 – 36,9) mg/l Si P (0,20 – 2000) mg/l PO 3- og 4 (0,0063 – 63,2) mmol/lPO 3- r 4 (0,065 – 652) mg/l P (0,15 – 1490) mg/l P O 2 5 La, Tl (0,020 – 100) mg/l Hg (0,050 – 10,0) mg/l Te (0,10 – 100) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","methodology_en":"Element concentrations Range: Fe (0,0050 – 1000) mg/l (0,0002 – 35,8) mmol/l r Mn (0,0050 – 1000) mg/l (0,0002 – 36,4) mmol/l r Cd (0,0010 – 1000) mg/l Be (0,0010 – 1000) mg/l Cr, Ti, V (0,0050 – 1000) mg/l Co, Zr (0,0050 – 1000) mg/l Mo (0,0050 – 1000) mg/l Cu,Ni (0,010 – 1000) mg/l Sb (0,050 – 100) mg/l Ag (0,020 – 100) mg/l As (0,050 – 100) mg/l B (0,050 – 1000) mg/l Zn (0,050 – 1000) mg/l Pb (0,020 – 100) mg/l Se, Sn (0,050 – 100) mg/l Al (0,10 – 1000) mg/l Bi (0,10 – 100) mg/l Ba (0,020 – 2000) mg/l (0,0003 – 29,1) mmol/l r Sr (0,020 – 1000) mg/l (0,0005 – 22,8) mmol/l r Li (0,10 – 1000) mg/l (0,015 – 144) mmol/l Ca (0,050 – 1000) mmol/l r (1,00 – 20000) mg/l Mg (0,050 – 1000) mmol/l r (0,60 – 12200) mg/l Na (0,050 – 5000) mmol/l (1,15 – 115000) mg/l K (0,050 – 1000) mmol/l (1,95 – 39100) mg/l S (5,00 – 3000) mg/l SO 2- tot. 4 (0,10 – 62,5 ) mmol/l SO 2- r 4 (1,70 – 999) mg/l S Si (0,50 – 100) mg/l SiO 2- tot. 3 (0,013 – 2,63) mmol/l SiO 2- r 3 (0,40 – 79,0) mg/l SiO 2 (0,19 – 36,9) mg/l Si P (0,20 – 2000) mg/l PO 3- tot. 4 (0,0063 – 63,2) mmol/lPO 3- r 4 (0,065 – 652) mg/l P (0,15 – 1490) mg/l P O 2 5 La, Tl (0,020 – 100) mg/l Hg (0,050 – 10,0) mg/l Te (0,10 – 100) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pierwiastków Zakres: Fe (0,0050 – 1000) mg/l (0,0002 – 35,8) mmol/l r Mn (0,0050 – 1000) mg/l (0,0002 – 36,4) mmol/l r Cd (0,0010 – 1000) mg/l Be (0,0010 – 1000) mg/l Cr, Ti, V (0,0050 – 1000) mg/l Co, Zr (0,0050 – 1000) mg/l Mo (0,0050 – 1000) mg/l Cu,Ni (0,010 – 1000) mg/l Sb (0,050 – 100) mg/l Ag (0,020 – 100) mg/l As (0,050 – 100) mg/l B (0,050 – 1000) mg/l Zn (0,050 – 1000) mg/l Pb (0,020 – 100) mg/l Se, Sn (0,050 – 100) mg/l Al (0,10 – 1000) mg/l Bi (0,10 – 100) mg/l Ba (0,020 – 2000) mg/l (0,0003 – 29,1) mmol/l r Sr (0,020 – 1000) mg/l (0,0005 – 22,8) mmol/l r Li (0,10 – 1000) mg/l (0,015 – 144) mmol/l Ca (0,050 – 1000) mmol/l r (1,00 – 20000) mg/l Mg (0,050 – 1000) mmol/l r (0,60 – 12200) mg/l Na (0,050 – 5000) mmol/l (1,15 – 115000) mg/l K (0,050 – 1000) mmol/l (1,95 – 39100) mg/l S (5,00 – 3000) mg/l SO 2- og 4 (0,10 – 62,5 ) mmol/l SO 2- r 4 (1,70 – 999) mg/l S Si (0,50 – 100) mg/l SiO 2- og 3 (0,013 – 2,63) mmol/l SiO 2- r 3 (0,40 – 79,0) mg/l SiO 2 (0,19 – 36,9) mg/l Si P (0,20 – 2000) mg/l PO 3- og 4 (0,0063 – 63,2) mmol/lPO 3- r 4 (0,065 – 652) mg/l P (0,15 – 1490) mg/l P O 2 5 La, Tl (0,020 – 100) mg/l Hg (0,050 – 10,0) mg/l Te (0,10 – 100) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1 z dn. 01.08.2025","norm_bases":["PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1 z dn. 01.08.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Sewage Stężenie pierwiastków Zakres: Fe (0,0050 – 1000) mg/l (0,0002 – 35,8) mmol/l r Mn (0,0050 – 1000) mg/l (0,0002 – 36,4) mmol/l r Cd (0,0010 – 1000) mg/l Be (0,0010 – 1000) mg/l Cr, Ti, V (0,0050 – 1000) mg/l Co, Zr (0,0050 – 1000) mg/l Mo (0,0050 – 1000) mg/l Cu,Ni (0,010 – 1000) mg/l Sb (0,050 – 100) mg/l Ag (0,020 – 100) mg/l As (0,050 – 100) mg/l B (0,050 – 1000) mg/l Zn (0,050 – 1000) mg/l Pb (0,020 – 100) mg/l Se, Sn (0,050 – 100) mg/l Al (0,10 – 1000) mg/l Bi (0,10 – 100) mg/l Ba (0,020 – 2000) mg/l (0,0003 – 29,1) mmol/l r Sr (0,020 – 1000) mg/l (0,0005 – 22,8) mmol/l r Li (0,10 – 1000) mg/l (0,015 – 144) mmol/l Ca (0,050 – 1000) mmol/l r (1,00 – 20000) mg/l Mg (0,050 – 1000) mmol/l r (0,60 – 12200) mg/l Na (0,050 – 5000) mmol/l (1,15 – 115000) mg/l K (0,050 – 1000) mmol/l (1,95 – 39100) mg/l S (5,00 – 3000) mg/l SO 2- og 4 (0,10 – 62,5 ) mmol/l SO 2- r 4 (1,70 – 999) mg/l S Si (0,50 – 100) mg/l SiO 2- og 3 (0,013 – 2,63) mmol/l SiO 2- r 3 (0,40 – 79,0) mg/l SiO 2 (0,19 – 36,9) mg/l Si P (0,20 – 2000) mg/l PO 3- og 4 (0,0063 – 63,2) mmol/lPO 3- r 4 (0,065 – 652) mg/l P (0,15 – 1490) mg/l P O 2 5 La, Tl (0,020 – 100) mg/l Hg (0,050 – 10,0) mg/l Te (0,10 – 100) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1 z dn. 01.08.2025 Scieki Sewage Stezenie pierwiastkow Zakres: Fe (0,0050 – 1000) mg/l (0,0002 – 35,8) mmol/l r Mn (0,0050 – 1000) mg/l (0,0002 – 36,4) mmol/l r Cd (0,0010 – 1000) mg/l Be (0,0010 – 1000) mg/l Cr, Ti, V (0,0050 – 1000) mg/l Co, Zr (0,0050 – 1000) mg/l Mo (0,0050 – 1000) mg/l Cu,Ni (0,010 – 1000) mg/l Sb (0,050 – 100) mg/l Ag (0,020 – 100) mg/l As (0,050 – 100) mg/l B (0,050 – 1000) mg/l Zn (0,050 – 1000) mg/l Pb (0,020 – 100) mg/l Se, Sn (0,050 – 100) mg/l Al (0,10 – 1000) mg/l Bi (0,10 – 100) mg/l Ba (0,020 – 2000) mg/l (0,0003 – 29,1) mmol/l r Sr (0,020 – 1000) mg/l (0,0005 – 22,8) mmol/l r Li (0,10 – 1000) mg/l (0,015 – 144) mmol/l Ca (0,050 – 1000) mmol/l r (1,00 – 20000) mg/l Mg (0,050 – 1000) mmol/l r (0,60 – 12200) mg/l Na (0,050 – 5000) mmol/l (1,15 – 115000) mg/l K (0,050 – 1000) mmol/l (1,95 – 39100) mg/l S (5,00 – 3000) mg/l SO 2- og 4 (0,10 – 62,5 ) mmol/l SO 2- r 4 (1,70 – 999) mg/l S Si (0,50 – 100) mg/l SiO 2- og 3 (0,013 – 2,63) mmol/l SiO 2- r 3 (0,40 – 79,0) mg/l SiO 2 (0,19 – 36,9) mg/l Si P (0,20 – 2000) mg/l PO 3- og 4 (0,0063 – 63,2) mmol/lPO 3- r 4 (0,065 – 652) mg/l P (0,15 – 1490) mg/l P O 2 5 La, Tl (0,020 – 100) mg/l Hg (0,050 – 10,0) mg/l Te (0,10 – 100) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1 z dn. 01.08.2025","categories":["water"],"row_index":288,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage Element concentrations Range: Fe (0,0050 – 1000) mg/l (0,0002 – 35,8) mmol/l r Mn (0,0050 – 1000) mg/l (0,0002 – 36,4) mmol/l r Cd (0,0010 – 1000) mg/l Be (0,0010 – 1000) mg/l Cr, Ti, V (0,0050 – 1000) mg/l Co, Zr (0,0050 – 1000) mg/l Mo (0,0050 – 1000) mg/l Cu,Ni (0,010 – 1000) mg/l Sb (0,050 – 100) mg/l Ag (0,020 – 100) mg/l As (0,050 – 100) mg/l B (0,050 – 1000) mg/l Zn (0,050 – 1000) mg/l Pb (0,020 – 100) mg/l Se, Sn (0,050 – 100) mg/l Al (0,10 – 1000) mg/l Bi (0,10 – 100) mg/l Ba (0,020 – 2000) mg/l (0,0003 – 29,1) mmol/l r Sr (0,020 – 1000) mg/l (0,0005 – 22,8) mmol/l r Li (0,10 – 1000) mg/l (0,015 – 144) mmol/l Ca (0,050 – 1000) mmol/l r (1,00 – 20000) mg/l Mg (0,050 – 1000) mmol/l r (0,60 – 12200) mg/l Na (0,050 – 5000) mmol/l (1,15 – 115000) mg/l K (0,050 – 1000) mmol/l (1,95 – 39100) mg/l S (5,00 – 3000) mg/l SO 2- tot. 4 (0,10 – 62,5 ) mmol/l SO 2- r 4 (1,70 – 999) mg/l S Si (0,50 – 100) mg/l SiO 2- tot. 3 (0,013 – 2,63) mmol/l SiO 2- r 3 (0,40 – 79,0) mg/l SiO 2 (0,19 – 36,9) mg/l Si P (0,20 – 2000) mg/l PO 3- tot. 4 (0,0063 – 63,2) mmol/lPO 3- r 4 (0,065 – 652) mg/l P (0,15 – 1490) mg/l P O 2 5 La, Tl (0,020 – 100) mg/l Hg (0,050 – 10,0) mg/l Te (0,10 – 100) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1 z dn. 01.08.2025","search_zh":"废水 Sewage PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1 z dn. 01.08.2025","test_object_zh":"废水 Sewage"},{"_id":"6a5a55ef9af9f73f38250bbd","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Ścieki Sewage","test_object_en":"Sewage","methodology":"Elements concentration Range: Fe (0,0050 – 1000) mg/l (0,0002 – 35,8) mmol/l r Mn (0,0050 – 1000) mg/l (0,0002 – 36,4) mmol/l r Cd (0,0010 – 1000) mg/l Be (0,0010 – 1000) mg/l Cr, Ti, V (0,0050 – 1000) mg/l Co, Zr (0,0050 – 1000) mg/l Mo (0,0050 – 1000) mg/l Cu,Ni (0,010 – 1000) mg/l Sb (0,050 – 100) mg/l Ag (0,020 – 100) mg/l As (0,050 – 100) mg/l B (0,050 – 1000) mg/l Zn (0,050 – 1000) mg/l Pb (0,020 – 100) mg/l Se, Sn (0,050 – 100) mg/l Al (0,10 – 1000) mg/l Bi (0,10 – 100) mg/l Ba (0,020 – 2000) mg/l (0,0003 – 29,1) mmol/l r Sr (0,020 – 1000) mg/l (0,0005 – 22,8) mmol/l r Li (0,10 – 1000) mg/l (0,015 – 144) mmol/l Ca (0,050 – 1000) mmol/l r (1,00 – 20000) mg/l Mg (0,050 – 1000) mmol/l r (0,60 – 12200) mg/l Na (0,050 – 5000) mmol/l (1,15 – 115000) mg/l K (0,050 – 1000) mmol/l (1,95 – 39100) mg/l S (5,00 – 3000) mg/l SO 2- tot. 4 (0,10 – 62,5 ) mmol/l SO 2- r 4 (1,70 – 999) mg/l S Si (0,50 – 100) mg/l SiO 2- tot. 3 (0,013 – 2,63) mmol/l SiO 2- r 3 (0,40 – 79,0) mg/l SiO 2 (0,19 – 36,9) mg/l Si P (0,20 – 2000) mg/l PO 3- tot. 4 (0,0063 – 63,2) mmol/lPO 3- r 4 (0,065 – 652) mg/l P (0,15 – 1490) mg/l P O 2 5 La, Tl (0,020 – 100) mg/l Hg (0,050 – 10,0) mg/l Te (0,10 – 100) mg/l Inductively coupled plasma optical emission spectrometry method (ICP-OES)","methodology_en":"Elements concentration Range: Fe (0,0050 – 1000) mg/l (0,0002 – 35,8) mmol/l r Mn (0,0050 – 1000) mg/l (0,0002 – 36,4) mmol/l r Cd (0,0010 – 1000) mg/l Be (0,0010 – 1000) mg/l Cr, Ti, V (0,0050 – 1000) mg/l Co, Zr (0,0050 – 1000) mg/l Mo (0,0050 – 1000) mg/l Cu,Ni (0,010 – 1000) mg/l Sb (0,050 – 100) mg/l Ag (0,020 – 100) mg/l As (0,050 – 100) mg/l B (0,050 – 1000) mg/l Zn (0,050 – 1000) mg/l Pb (0,020 – 100) mg/l Se, Sn (0,050 – 100) mg/l Al (0,10 – 1000) mg/l Bi (0,10 – 100) mg/l Ba (0,020 – 2000) mg/l (0,0003 – 29,1) mmol/l r Sr (0,020 – 1000) mg/l (0,0005 – 22,8) mmol/l r Li (0,10 – 1000) mg/l (0,015 – 144) mmol/l Ca (0,050 – 1000) mmol/l r (1,00 – 20000) mg/l Mg (0,050 – 1000) mmol/l r (0,60 – 12200) mg/l Na (0,050 – 5000) mmol/l (1,15 – 115000) mg/l K (0,050 – 1000) mmol/l (1,95 – 39100) mg/l S (5,00 – 3000) mg/l SO 2- tot. 4 (0,10 – 62,5 ) mmol/l SO 2- r 4 (1,70 – 999) mg/l S Si (0,50 – 100) mg/l SiO 2- tot. 3 (0,013 – 2,63) mmol/l SiO 2- r 3 (0,40 – 79,0) mg/l SiO 2 (0,19 – 36,9) mg/l Si P (0,20 – 2000) mg/l PO 3- tot. 4 (0,0063 – 63,2) mmol/lPO 3- r 4 (0,065 – 652) mg/l P (0,15 – 1490) mg/l P O 2 5 La, Tl (0,020 – 100) mg/l Hg (0,050 – 10,0) mg/l Te (0,10 – 100) mg/l Inductively coupled plasma optical emission spectrometry method (ICP-OES)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Elements concentration Range: Fe (0,0050 – 1000) mg/l (0,0002 – 35,8) mmol/l r Mn (0,0050 – 1000) mg/l (0,0002 – 36,4) mmol/l r Cd (0,0010 – 1000) mg/l Be (0,0010 – 1000) mg/l Cr, Ti, V (0,0050 – 1000) mg/l Co, Zr (0,0050 – 1000) mg/l Mo (0,0050 – 1000) mg/l Cu,Ni (0,010 – 1000) mg/l Sb (0,050 – 100) mg/l Ag (0,020 – 100) mg/l As (0,050 – 100) mg/l B (0,050 – 1000) mg/l Zn (0,050 – 1000) mg/l Pb (0,020 – 100) mg/l Se, Sn (0,050 – 100) mg/l Al (0,10 – 1000) mg/l Bi (0,10 – 100) mg/l Ba (0,020 – 2000) mg/l (0,0003 – 29,1) mmol/l r Sr (0,020 – 1000) mg/l (0,0005 – 22,8) mmol/l r Li (0,10 – 1000) mg/l (0,015 – 144) mmol/l Ca (0,050 – 1000) mmol/l r (1,00 – 20000) mg/l Mg (0,050 – 1000) mmol/l r (0,60 – 12200) mg/l Na (0,050 – 5000) mmol/l (1,15 – 115000) mg/l K (0,050 – 1000) mmol/l (1,95 – 39100) mg/l S (5,00 – 3000) mg/l SO 2- tot. 4 (0,10 – 62,5 ) mmol/l SO 2- r 4 (1,70 – 999) mg/l S Si (0,50 – 100) mg/l SiO 2- tot. 3 (0,013 – 2,63) mmol/l SiO 2- r 3 (0,40 – 79,0) mg/l SiO 2 (0,19 – 36,9) mg/l Si P (0,20 – 2000) mg/l PO 3- tot. 4 (0,0063 – 63,2) mmol/lPO 3- r 4 (0,065 – 652) mg/l P (0,15 – 1490) mg/l P O 2 5 La, Tl (0,020 – 100) mg/l Hg (0,050 – 10,0) mg/l Te (0,10 – 100) mg/l Inductively coupled plasma optical emission spectrometry method (ICP-OES)","reference":"PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1st of 01/08/2025","norm_bases":["PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Sewage Elements concentration Range: Fe (0,0050 – 1000) mg/l (0,0002 – 35,8) mmol/l r Mn (0,0050 – 1000) mg/l (0,0002 – 36,4) mmol/l r Cd (0,0010 – 1000) mg/l Be (0,0010 – 1000) mg/l Cr, Ti, V (0,0050 – 1000) mg/l Co, Zr (0,0050 – 1000) mg/l Mo (0,0050 – 1000) mg/l Cu,Ni (0,010 – 1000) mg/l Sb (0,050 – 100) mg/l Ag (0,020 – 100) mg/l As (0,050 – 100) mg/l B (0,050 – 1000) mg/l Zn (0,050 – 1000) mg/l Pb (0,020 – 100) mg/l Se, Sn (0,050 – 100) mg/l Al (0,10 – 1000) mg/l Bi (0,10 – 100) mg/l Ba (0,020 – 2000) mg/l (0,0003 – 29,1) mmol/l r Sr (0,020 – 1000) mg/l (0,0005 – 22,8) mmol/l r Li (0,10 – 1000) mg/l (0,015 – 144) mmol/l Ca (0,050 – 1000) mmol/l r (1,00 – 20000) mg/l Mg (0,050 – 1000) mmol/l r (0,60 – 12200) mg/l Na (0,050 – 5000) mmol/l (1,15 – 115000) mg/l K (0,050 – 1000) mmol/l (1,95 – 39100) mg/l S (5,00 – 3000) mg/l SO 2- tot. 4 (0,10 – 62,5 ) mmol/l SO 2- r 4 (1,70 – 999) mg/l S Si (0,50 – 100) mg/l SiO 2- tot. 3 (0,013 – 2,63) mmol/l SiO 2- r 3 (0,40 – 79,0) mg/l SiO 2 (0,19 – 36,9) mg/l Si P (0,20 – 2000) mg/l PO 3- tot. 4 (0,0063 – 63,2) mmol/lPO 3- r 4 (0,065 – 652) mg/l P (0,15 – 1490) mg/l P O 2 5 La, Tl (0,020 – 100) mg/l Hg (0,050 – 10,0) mg/l Te (0,10 – 100) mg/l Inductively coupled plasma optical emission spectrometry method (ICP-OES) PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1st of 01/08/2025 Scieki Sewage Elements concentration Range: Fe (0,0050 – 1000) mg/l (0,0002 – 35,8) mmol/l r Mn (0,0050 – 1000) mg/l (0,0002 – 36,4) mmol/l r Cd (0,0010 – 1000) mg/l Be (0,0010 – 1000) mg/l Cr, Ti, V (0,0050 – 1000) mg/l Co, Zr (0,0050 – 1000) mg/l Mo (0,0050 – 1000) mg/l Cu,Ni (0,010 – 1000) mg/l Sb (0,050 – 100) mg/l Ag (0,020 – 100) mg/l As (0,050 – 100) mg/l B (0,050 – 1000) mg/l Zn (0,050 – 1000) mg/l Pb (0,020 – 100) mg/l Se, Sn (0,050 – 100) mg/l Al (0,10 – 1000) mg/l Bi (0,10 – 100) mg/l Ba (0,020 – 2000) mg/l (0,0003 – 29,1) mmol/l r Sr (0,020 – 1000) mg/l (0,0005 – 22,8) mmol/l r Li (0,10 – 1000) mg/l (0,015 – 144) mmol/l Ca (0,050 – 1000) mmol/l r (1,00 – 20000) mg/l Mg (0,050 – 1000) mmol/l r (0,60 – 12200) mg/l Na (0,050 – 5000) mmol/l (1,15 – 115000) mg/l K (0,050 – 1000) mmol/l (1,95 – 39100) mg/l S (5,00 – 3000) mg/l SO 2- tot. 4 (0,10 – 62,5 ) mmol/l SO 2- r 4 (1,70 – 999) mg/l S Si (0,50 – 100) mg/l SiO 2- tot. 3 (0,013 – 2,63) mmol/l SiO 2- r 3 (0,40 – 79,0) mg/l SiO 2 (0,19 – 36,9) mg/l Si P (0,20 – 2000) mg/l PO 3- tot. 4 (0,0063 – 63,2) mmol/lPO 3- r 4 (0,065 – 652) mg/l P (0,15 – 1490) mg/l P O 2 5 La, Tl (0,020 – 100) mg/l Hg (0,050 – 10,0) mg/l Te (0,10 – 100) mg/l Inductively coupled plasma optical emission spectrometry method (ICP-OES) PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1st of 01/08/2025","categories":["water","environment"],"row_index":289,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage Elements concentration Range: Fe (0,0050 – 1000) mg/l (0,0002 – 35,8) mmol/l r Mn (0,0050 – 1000) mg/l (0,0002 – 36,4) mmol/l r Cd (0,0010 – 1000) mg/l Be (0,0010 – 1000) mg/l Cr, Ti, V (0,0050 – 1000) mg/l Co, Zr (0,0050 – 1000) mg/l Mo (0,0050 – 1000) mg/l Cu,Ni (0,010 – 1000) mg/l Sb (0,050 – 100) mg/l Ag (0,020 – 100) mg/l As (0,050 – 100) mg/l B (0,050 – 1000) mg/l Zn (0,050 – 1000) mg/l Pb (0,020 – 100) mg/l Se, Sn (0,050 – 100) mg/l Al (0,10 – 1000) mg/l Bi (0,10 – 100) mg/l Ba (0,020 – 2000) mg/l (0,0003 – 29,1) mmol/l r Sr (0,020 – 1000) mg/l (0,0005 – 22,8) mmol/l r Li (0,10 – 1000) mg/l (0,015 – 144) mmol/l Ca (0,050 – 1000) mmol/l r (1,00 – 20000) mg/l Mg (0,050 – 1000) mmol/l r (0,60 – 12200) mg/l Na (0,050 – 5000) mmol/l (1,15 – 115000) mg/l K (0,050 – 1000) mmol/l (1,95 – 39100) mg/l S (5,00 – 3000) mg/l SO 2- tot. 4 (0,10 – 62,5 ) mmol/l SO 2- r 4 (1,70 – 999) mg/l S Si (0,50 – 100) mg/l SiO 2- tot. 3 (0,013 – 2,63) mmol/l SiO 2- r 3 (0,40 – 79,0) mg/l SiO 2 (0,19 – 36,9) mg/l Si P (0,20 – 2000) mg/l PO 3- tot. 4 (0,0063 – 63,2) mmol/lPO 3- r 4 (0,065 – 652) mg/l P (0,15 – 1490) mg/l P O 2 5 La, Tl (0,020 – 100) mg/l Hg (0,050 – 10,0) mg/l Te (0,10 – 100) mg/l Inductively coupled plasma optical emission spectrometry method (ICP-OES) PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1st of 01/08/2025","search_zh":"废水 Sewage PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1st of 01/08/2025","test_object_zh":"废水 Sewage"},{"_id":"6a5a55ef9af9f73f38250bbe","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"pH Zakres: 2,0 – 13,0 Metoda potencjometryczna pH value Range: 2,0 – 13,0 Potentiometric method","methodology_en":"pH value Range: 2,0 – 13,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 2,0 – 13,0 Metoda potencjometryczna pH value Range: 2,0 – 13,0 Potentiometric method","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage pH Zakres: 2,0 – 13,0 Metoda potencjometryczna pH value Range: 2,0 – 13,0 Potentiometric method PN-EN ISO 10523:2012 Woda, scieki Water, sewage pH Zakres: 2,0 – 13,0 Metoda potencjometryczna pH value Range: 2,0 – 13,0 Potentiometric method PN-EN ISO 10523:2012","categories":["water"],"row_index":290,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage pH value Range: 2,0 – 13,0 Potentiometric method PN-EN ISO 10523:2012","search_zh":"水、废水 PN-EN ISO 10523:2012","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250bbf","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Przewodność elektryczna właściwa Zakres: (10 – 250000) S/cm Metoda konduktometryczna Electrical conductivity Range: (10 – 250000) S/cm Conductometric method","methodology_en":"Electrical conductivity Range: (10 – 250000) S/cm Conductometric method Electrical conductivity Range: (10 – 250000) S/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (10 – 250000) S/cm Metoda konduktometryczna Electrical conductivity Range: (10 – 250000) S/cm Conductometric method","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Przewodność elektryczna właściwa Zakres: (10 – 250000) S/cm Metoda konduktometryczna Electrical conductivity Range: (10 – 250000) S/cm Conductometric method PN-EN 27888:1999 Woda, scieki Water, sewage Przewodnosc elektryczna wlasciwa Zakres: (10 – 250000) S/cm Metoda konduktometryczna Electrical conductivity Range: (10 – 250000) S/cm Conductometric method PN-EN 27888:1999","categories":["water"],"row_index":291,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Electrical conductivity Range: (10 – 250000) S/cm Conductometric method Electrical conductivity Range: (10 – 250000) S/cm Conductometric method PN-EN 27888:1999","search_zh":"水、废水 PN-EN 27888:1999","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250bc0","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Stężenie chlorków Zakres: (0,14 – 5000) mmol/I (5,0 – 177300) mg/l Metoda miareczkowa Chloride concentration Range: (0,14 – 5000) mmol/I (5,0 – 177300) mg/l Titrimetric method","methodology_en":"Chloride concentration Range: (0,14 – 5000) mmol/I (5,0 – 177300) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (0,14 – 5000) mmol/I (5,0 – 177300) mg/l Metoda miareczkowa Chloride concentration Range: (0,14 – 5000) mmol/I (5,0 – 177300) mg/l Titrimetric method","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Stężenie chlorków Zakres: (0,14 – 5000) mmol/I (5,0 – 177300) mg/l Metoda miareczkowa Chloride concentration Range: (0,14 – 5000) mmol/I (5,0 – 177300) mg/l Titrimetric method PN-ISO 9297:1994 Woda, scieki Water, sewage Stezenie chlorkow Zakres: (0,14 – 5000) mmol/I (5,0 – 177300) mg/l Metoda miareczkowa Chloride concentration Range: (0,14 – 5000) mmol/I (5,0 – 177300) mg/l Titrimetric method PN-ISO 9297:1994","categories":["water"],"row_index":292,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Chloride concentration Range: (0,14 – 5000) mmol/I (5,0 – 177300) mg/l Titrimetric method PN-ISO 9297:1994","search_zh":"水、废水 PN-ISO 9297:1994","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250bc1","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Stężenie siarczanów Zakres: (10 – 10000) mg/l (0,21 – 208) mmol/l r Metoda wagowa Sulfate concentration Range: (10 – 10000) mg/l (0,21 – 208) mmol/l r Gravimetric method","methodology_en":"Sulfate concentration Range: (10 – 10000) mg/l (0,21 – 208) mmol/l r Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie siarczanów Zakres: (10 – 10000) mg/l (0,21 – 208) mmol/l r Metoda wagowa Sulfate concentration Range: (10 – 10000) mg/l (0,21 – 208) mmol/l r Gravimetric method","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Stężenie siarczanów Zakres: (10 – 10000) mg/l (0,21 – 208) mmol/l r Metoda wagowa Sulfate concentration Range: (10 – 10000) mg/l (0,21 – 208) mmol/l r Gravimetric method PN-ISO 9280:2002 Woda, scieki Water, sewage Stezenie siarczanow Zakres: (10 – 10000) mg/l (0,21 – 208) mmol/l r Metoda wagowa Sulfate concentration Range: (10 – 10000) mg/l (0,21 – 208) mmol/l r Gravimetric method PN-ISO 9280:2002","categories":["water"],"row_index":293,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Sulfate concentration Range: (10 – 10000) mg/l (0,21 – 208) mmol/l r Gravimetric method PN-ISO 9280:2002","search_zh":"水、废水 PN-ISO 9280:2002","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250bc2","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Całkowite substancje rozpuszczone (TDS) Zakres: (10 – 250000) mg/I Metoda wagowa Total dissolved solids (TDS) Range: (10 – 250000) mg/I Gravimetric method","methodology_en":"Total dissolved solids (TDS) Range: (10 – 250000) mg/I Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Całkowite substancje rozpuszczone (TDS) Zakres: (10 – 250000) mg/I Metoda wagowa Total dissolved solids (TDS) Range: (10 – 250000) mg/I Gravimetric method","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Całkowite substancje rozpuszczone (TDS) Zakres: (10 – 250000) mg/I Metoda wagowa Total dissolved solids (TDS) Range: (10 – 250000) mg/I Gravimetric method PN-EN 15216:2022-03 Woda, scieki Water, sewage Calkowite substancje rozpuszczone (TDS) Zakres: (10 – 250000) mg/I Metoda wagowa Total dissolved solids (TDS) Range: (10 – 250000) mg/I Gravimetric method PN-EN 15216:2022-03","categories":["water"],"row_index":294,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Total dissolved solids (TDS) Range: (10 – 250000) mg/I Gravimetric method PN-EN 15216:2022-03","search_zh":"水、废水 PN-EN 15216:2022-03","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250bc3","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Substancje rozpuszczone, mineralne (nielotne) i lotne Zakres: (10 – 250000) mg/I Sucha pozostałość, mineralna (nielotna) i lotna Zakres: (10 – 100000) mg/l Metoda wagowa Dissolved solids, mineral (non-volatile) and volatile Range: (10 – 250000) mg/I Solids – total mineral (non-volatile) and volatile Range: (10 – 100000) mg/l Gravimetric method","methodology_en":"Dissolved solids, mineral (non-volatile) and volatile Range: (10 – 250000) mg/I Solids – total mineral (non-volatile) and volatile Range: (10 – 100000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Substancje rozpuszczone, mineralne (nielotne) i lotne Zakres: (10 – 250000) mg/I Sucha pozostałość, mineralna (nielotna) i lotna Zakres: (10 – 100000) mg/l Metoda wagowa Dissolved solids, mineral (non-volatile) and volatile Range: (10 – 250000) mg/I Solids – total mineral (non-volatile) and volatile Range: (10 – 100000) mg/l Gravimetric method","reference":"PN-78/C-04541","norm_bases":["PN-78/C-04541"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Substancje rozpuszczone, mineralne (nielotne) i lotne Zakres: (10 – 250000) mg/I Sucha pozostałość, mineralna (nielotna) i lotna Zakres: (10 – 100000) mg/l Metoda wagowa Dissolved solids, mineral (non-volatile) and volatile Range: (10 – 250000) mg/I Solids – total mineral (non-volatile) and volatile Range: (10 – 100000) mg/l Gravimetric method PN-78/C-04541 Woda, scieki Water, sewage Substancje rozpuszczone, mineralne (nielotne) i lotne Zakres: (10 – 250000) mg/I Sucha pozostalosc, mineralna (nielotna) i lotna Zakres: (10 – 100000) mg/l Metoda wagowa Dissolved solids, mineral (non-volatile) and volatile Range: (10 – 250000) mg/I Solids – total mineral (non-volatile) and volatile Range: (10 – 100000) mg/l Gravimetric method PN-78/C-04541","categories":["water"],"row_index":295,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Dissolved solids, mineral (non-volatile) and volatile Range: (10 – 250000) mg/I Solids – total mineral (non-volatile) and volatile Range: (10 – 100000) mg/l Gravimetric method PN-78/C-04541","search_zh":"水、废水 PN-78/C-04541","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250bc4","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Zasadowość mineralna i ogólna Zakres: (0,40 – 200) mmol/l Metoda miareczkowa Zakres: (0,10 – 200) mmol/l Metoda miareczkowania potencjometrycznego Stężenie węglanów Stężenie wodorowęglanów Stężenie wodorotlenków Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Twardość węglanowa Twardość niewęglanowa (z obliczeń) Alkalinity - mineral and total Range: (0,40 – 200) mmol/l Titrimetric method Range: (0,10 – 200) mmol/l Potentiometric titration method Carbonates concentration Hydrocarbonates concentration Hydroxides concentration Total hardness (sum of calcium and magnesium) Carbonate hardness Non-carbonate hardness (from calculations)","methodology_en":"Alkalinity - mineral and total Range: (0,40 – 200) mmol/l Titrimetric method Range: (0,10 – 200) mmol/l Potentiometric titration method Carbonates concentration Hydrocarbonates concentration Hydroxides concentration Total hardness (sum of calcium and magnesium) Carbonate hardness Non-carbonate hardness (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zasadowość mineralna i ogólna Zakres: (0,40 – 200) mmol/l Metoda miareczkowa Zakres: (0,10 – 200) mmol/l Metoda miareczkowania potencjometrycznego Stężenie węglanów Stężenie wodorowęglanów Stężenie wodorotlenków Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Twardość węglanowa Twardość niewęglanowa (z obliczeń) Alkalinity - mineral and total Range: (0,40 – 200) mmol/l Titrimetric method Range: (0,10 – 200) mmol/l Potentiometric titration method Carbonates concentration Hydrocarbonates concentration Hydroxides concentration Total hardness (sum of calcium and magnesium) Carbonate hardness Non-carbonate hardness (from calculations)","reference":"PN-EN ISO 9963-1:2001+Ap1:2004 SO-4/ZLGIG/PB.07.95 ed. 1 z dnia 01.08.2025 PN-EN ISO 9963-1:2001+Ap1:2004 SO-4/ZLGIG/PB.07.95 ed. 1st of 01/08/2025","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004 SO-4/ZLGIG/PB.07.95 ed. 1 z dnia 01.08.2025 PN-EN ISO 9963-1:2001+Ap1:2004 SO-4/ZLGIG/PB.07.95 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Zasadowość mineralna i ogólna Zakres: (0,40 – 200) mmol/l Metoda miareczkowa Zakres: (0,10 – 200) mmol/l Metoda miareczkowania potencjometrycznego Stężenie węglanów Stężenie wodorowęglanów Stężenie wodorotlenków Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Twardość węglanowa Twardość niewęglanowa (z obliczeń) Alkalinity - mineral and total Range: (0,40 – 200) mmol/l Titrimetric method Range: (0,10 – 200) mmol/l Potentiometric titration method Carbonates concentration Hydrocarbonates concentration Hydroxides concentration Total hardness (sum of calcium and magnesium) Carbonate hardness Non-carbonate hardness (from calculations) PN-EN ISO 9963-1:2001+Ap1:2004 SO-4/ZLGIG/PB.07.95 ed. 1 z dnia 01.08.2025 PN-EN ISO 9963-1:2001+Ap1:2004 SO-4/ZLGIG/PB.07.95 ed. 1st of 01/08/2025 Woda, scieki Water, sewage Zasadowosc mineralna i ogolna Zakres: (0,40 – 200) mmol/l Metoda miareczkowa Zakres: (0,10 – 200) mmol/l Metoda miareczkowania potencjometrycznego Stezenie weglanow Stezenie wodoroweglanow Stezenie wodorotlenkow Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna) Twardosc weglanowa Twardosc nieweglanowa (z obliczen) Alkalinity - mineral and total Range: (0,40 – 200) mmol/l Titrimetric method Range: (0,10 – 200) mmol/l Potentiometric titration method Carbonates concentration Hydrocarbonates concentration Hydroxides concentration Total hardness (sum of calcium and magnesium) Carbonate hardness Non-carbonate hardness (from calculations) PN-EN ISO 9963-1:2001+Ap1:2004 SO-4/ZLGIG/PB.07.95 ed. 1 z dnia 01.08.2025 PN-EN ISO 9963-1:2001+Ap1:2004 SO-4/ZLGIG/PB.07.95 ed. 1st of 01/08/2025","categories":["water"],"row_index":296,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Alkalinity - mineral and total Range: (0,40 – 200) mmol/l Titrimetric method Range: (0,10 – 200) mmol/l Potentiometric titration method Carbonates concentration Hydrocarbonates concentration Hydroxides concentration Total hardness (sum of calcium and magnesium) Carbonate hardness Non-carbonate hardness (from calculations) PN-EN ISO 9963-1:2001+Ap1:2004 SO-4/ZLGIG/PB.07.95 ed. 1 z dnia 01.08.2025 PN-EN ISO 9963-1:2001+Ap1:2004 SO-4/ZLGIG/PB.07.95 ed. 1st of 01/08/2025","search_zh":"水、废水 PN-EN ISO 9963-1:2001+Ap1:2004 SO-4/ZLGIG/PB.07.95 ed. 1 z dnia 01.08.2025 PN-EN ISO 9963-1:2001+Ap1:2004 SO-4/ZLGIG/PB.07.95 ed. 1st of 01/08/2025","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250bc5","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Tlen rozpuszczony Zakres: (0,1 – 15,0) mg/l O 2 Metoda elektrochemiczna Dissolved oxygen Range: (0,1 – 15,0) mg/l O 2 Electrochemical method","methodology_en":"Dissolved oxygen Range: (0,1 – 15,0) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Tlen rozpuszczony Zakres: (0,1 – 15,0) mg/l O 2 Metoda elektrochemiczna Dissolved oxygen Range: (0,1 – 15,0) mg/l O 2 Electrochemical method","reference":"PN-EN ISO 5814:2013-04","norm_bases":["PN-EN ISO 5814:2013-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Tlen rozpuszczony Zakres: (0,1 – 15,0) mg/l O 2 Metoda elektrochemiczna Dissolved oxygen Range: (0,1 – 15,0) mg/l O 2 Electrochemical method PN-EN ISO 5814:2013-04 Woda, scieki Water, sewage Tlen rozpuszczony Zakres: (0,1 – 15,0) mg/l O 2 Metoda elektrochemiczna Dissolved oxygen Range: (0,1 – 15,0) mg/l O 2 Electrochemical method PN-EN ISO 5814:2013-04","categories":["water"],"row_index":297,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Dissolved oxygen Range: (0,1 – 15,0) mg/l O 2 Electrochemical method PN-EN ISO 5814:2013-04","search_zh":"水、废水 PN-EN ISO 5814:2013-04","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250bc6","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Chemiczne zapotrzebowanie tlenu (ChZT ) Cr Zakres: (10 – 10000) mg/l O 2 Metoda spektrofotometryczna Chemical oxygen demand (COD ) Cr Range: (10 – 10000) mg/l O 2 Spectrophotometric method","methodology_en":"Chemical oxygen demand (COD ) Cr Range: (10 – 10000) mg/l O 2 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu (ChZT ) Cr Zakres: (10 – 10000) mg/l O 2 Metoda spektrofotometryczna Chemical oxygen demand (COD ) Cr Range: (10 – 10000) mg/l O 2 Spectrophotometric method","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Chemiczne zapotrzebowanie tlenu (ChZT ) Cr Zakres: (10 – 10000) mg/l O 2 Metoda spektrofotometryczna Chemical oxygen demand (COD ) Cr Range: (10 – 10000) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005 Woda, scieki Water, sewage Chemiczne zapotrzebowanie tlenu (ChZT ) Cr Zakres: (10 – 10000) mg/l O 2 Metoda spektrofotometryczna Chemical oxygen demand (COD ) Cr Range: (10 – 10000) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005","categories":["water"],"row_index":298,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Chemical oxygen demand (COD ) Cr Range: (10 – 10000) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005","search_zh":"水、废水 PN-ISO 15705:2005","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250bc7","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Stężenie azotynów Zakres: (0,0060 – 100) mg/l (0,00013 – 2,17) mmol/l Stężenie azotu azotynowego (0,0018 – 30,4) mg/l Metoda spektrofotometryczna Nitrite concentration Range: (0,0060 – 100) mg/l (0,00013 – 2,17) mmol/l Nitrite nitrogen concentration (0,0018 – 30,4) mg/l Spectrophotometric method","methodology_en":"Nitrite concentration Range: (0,0060 – 100) mg/l (0,00013 – 2,17) mmol/l Nitrite nitrogen concentration (0,0018 – 30,4) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotynów Zakres: (0,0060 – 100) mg/l (0,00013 – 2,17) mmol/l Stężenie azotu azotynowego (0,0018 – 30,4) mg/l Metoda spektrofotometryczna Nitrite concentration Range: (0,0060 – 100) mg/l (0,00013 – 2,17) mmol/l Nitrite nitrogen concentration (0,0018 – 30,4) mg/l Spectrophotometric method","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Stężenie azotynów Zakres: (0,0060 – 100) mg/l (0,00013 – 2,17) mmol/l Stężenie azotu azotynowego (0,0018 – 30,4) mg/l Metoda spektrofotometryczna Nitrite concentration Range: (0,0060 – 100) mg/l (0,00013 – 2,17) mmol/l Nitrite nitrogen concentration (0,0018 – 30,4) mg/l Spectrophotometric method PN-EN 26777:1999 Woda, scieki Water, sewage Stezenie azotynow Zakres: (0,0060 – 100) mg/l (0,00013 – 2,17) mmol/l Stezenie azotu azotynowego (0,0018 – 30,4) mg/l Metoda spektrofotometryczna Nitrite concentration Range: (0,0060 – 100) mg/l (0,00013 – 2,17) mmol/l Nitrite nitrogen concentration (0,0018 – 30,4) mg/l Spectrophotometric method PN-EN 26777:1999","categories":["water"],"row_index":299,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Nitrite concentration Range: (0,0060 – 100) mg/l (0,00013 – 2,17) mmol/l Nitrite nitrogen concentration (0,0018 – 30,4) mg/l Spectrophotometric method PN-EN 26777:1999","search_zh":"水、废水 PN-EN 26777:1999","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250bc8","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Stężenie jodków Zakres: (0,40 – 250) mg/l (0,0032 – 1,97) mmol/l Stężenie bromków Zakres: (0,40 – 500) mg/l (0,0050 – 6,26) mmol/l Metoda miareczkowa Iodide concentration Range: (0,40 – 250) mg/l (0,0032 – 1,97) mmol/l Bromide concentration Range: (0,40 – 500) mg/l (0,0050 – 6,26) mmol/l Titrimetric method","methodology_en":"Iodide concentration Range: (0,40 – 250) mg/l (0,0032 – 1,97) mmol/l Bromide concentration Range: (0,40 – 500) mg/l (0,0050 – 6,26) mmol/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie jodków Zakres: (0,40 – 250) mg/l (0,0032 – 1,97) mmol/l Stężenie bromków Zakres: (0,40 – 500) mg/l (0,0050 – 6,26) mmol/l Metoda miareczkowa Iodide concentration Range: (0,40 – 250) mg/l (0,0032 – 1,97) mmol/l Bromide concentration Range: (0,40 – 500) mg/l (0,0050 – 6,26) mmol/l Titrimetric method","reference":"SO-4/ZLGIG/PB.07.29 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.07.29 ed. 1st of 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.07.29 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.07.29 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Stężenie jodków Zakres: (0,40 – 250) mg/l (0,0032 – 1,97) mmol/l Stężenie bromków Zakres: (0,40 – 500) mg/l (0,0050 – 6,26) mmol/l Metoda miareczkowa Iodide concentration Range: (0,40 – 250) mg/l (0,0032 – 1,97) mmol/l Bromide concentration Range: (0,40 – 500) mg/l (0,0050 – 6,26) mmol/l Titrimetric method SO-4/ZLGIG/PB.07.29 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.07.29 ed. 1st of 01/08/2025 Woda, scieki Water, sewage Stezenie jodkow Zakres: (0,40 – 250) mg/l (0,0032 – 1,97) mmol/l Stezenie bromkow Zakres: (0,40 – 500) mg/l (0,0050 – 6,26) mmol/l Metoda miareczkowa Iodide concentration Range: (0,40 – 250) mg/l (0,0032 – 1,97) mmol/l Bromide concentration Range: (0,40 – 500) mg/l (0,0050 – 6,26) mmol/l Titrimetric method SO-4/ZLGIG/PB.07.29 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.07.29 ed. 1st of 01/08/2025","categories":["water"],"row_index":300,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Iodide concentration Range: (0,40 – 250) mg/l (0,0032 – 1,97) mmol/l Bromide concentration Range: (0,40 – 500) mg/l (0,0050 – 6,26) mmol/l Titrimetric method SO-4/ZLGIG/PB.07.29 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.07.29 ed. 1st of 01/08/2025","search_zh":"水、废水 SO-4/ZLGIG/PB.07.29 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.07.29 ed. 1st of 01/08/2025","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250bc9","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Biochemiczne zapotrzebowanie tlenu- BZT 5 BZT 2+5 Zakres: (0,50 – 6,0) mg/l O 2 (3 – 6000) mg/l O 2 Metoda elektrochemiczna Biochemical oxygen demand- BOD 5 BOD 2+5 Range: (0,50 – 6,0) mg/l O 2 (3 – 6000) mg/l O 2 Electrochemical method","methodology_en":"Biochemical oxygen demand- BOD 5 BOD 2+5 Range: (0,50 – 6,0) mg/l O 2 (3 – 6000) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu- BZT 5 BZT 2+5 Zakres: (0,50 – 6,0) mg/l O 2 (3 – 6000) mg/l O 2 Metoda elektrochemiczna Biochemical oxygen demand- BOD 5 BOD 2+5 Range: (0,50 – 6,0) mg/l O 2 (3 – 6000) mg/l O 2 Electrochemical method","reference":"PN-EN ISO 5815-1:2019-12 PN-EN 1899-2:2002","norm_bases":["PN-EN ISO 5815-1:2019-12 PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Biochemiczne zapotrzebowanie tlenu- BZT 5 BZT 2+5 Zakres: (0,50 – 6,0) mg/l O 2 (3 – 6000) mg/l O 2 Metoda elektrochemiczna Biochemical oxygen demand- BOD 5 BOD 2+5 Range: (0,50 – 6,0) mg/l O 2 (3 – 6000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12 PN-EN 1899-2:2002 Woda, scieki Water, sewage Biochemiczne zapotrzebowanie tlenu- BZT 5 BZT 2+5 Zakres: (0,50 – 6,0) mg/l O 2 (3 – 6000) mg/l O 2 Metoda elektrochemiczna Biochemical oxygen demand- BOD 5 BOD 2+5 Range: (0,50 – 6,0) mg/l O 2 (3 – 6000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12 PN-EN 1899-2:2002","categories":["water"],"row_index":301,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Biochemical oxygen demand- BOD 5 BOD 2+5 Range: (0,50 – 6,0) mg/l O 2 (3 – 6000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12 PN-EN 1899-2:2002","search_zh":"水、废水 PN-EN ISO 5815-1:2019-12 PN-EN 1899-2:2002","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250bca","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Stężenie anionowych substancji powierzchniowo-czynnych (detergenty/surfaktanty anionowe) Zakres: (0,10 – 100) mg/l Metoda spektrofotometryczna Anionic surfactants (detergents) concentration Range: (0,10 – 100) mg/l Spectrophotometric method","methodology_en":"Anionic surfactants (detergents) concentration Range: (0,10 – 100) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie anionowych substancji powierzchniowo-czynnych (detergenty/surfaktanty anionowe) Zakres: (0,10 – 100) mg/l Metoda spektrofotometryczna Anionic surfactants (detergents) concentration Range: (0,10 – 100) mg/l Spectrophotometric method","reference":"PN-EN 903:2002 z wył. pkt 7.1 PN-EN 903:2002 exc. pt 7.1","norm_bases":["PN-EN 903:2002 z wył. pkt 7.1 PN-EN 903:2002 exc. pt 7.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Stężenie anionowych substancji powierzchniowo-czynnych (detergenty/surfaktanty anionowe) Zakres: (0,10 – 100) mg/l Metoda spektrofotometryczna Anionic surfactants (detergents) concentration Range: (0,10 – 100) mg/l Spectrophotometric method PN-EN 903:2002 z wył. pkt 7.1 PN-EN 903:2002 exc. pt 7.1 Woda, scieki Water, sewage Stezenie anionowych substancji powierzchniowo-czynnych (detergenty/surfaktanty anionowe) Zakres: (0,10 – 100) mg/l Metoda spektrofotometryczna Anionic surfactants (detergents) concentration Range: (0,10 – 100) mg/l Spectrophotometric method PN-EN 903:2002 z wyl. pkt 7.1 PN-EN 903:2002 exc. pt 7.1","categories":["water"],"row_index":302,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Anionic surfactants (detergents) concentration Range: (0,10 – 100) mg/l Spectrophotometric method PN-EN 903:2002 z wył. pkt 7.1 PN-EN 903:2002 exc. pt 7.1","search_zh":"水、废水 PN-EN 903:2002 z wył. pkt 7.1 PN-EN 903:2002 exc. pt 7.1","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250bcb","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Stężenie anionowych substancji powierzchniowo-czynnych (detergenty/surfaktanty anionowe) Zakres (0,010 - 100) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną Anionic surfactants (detergents) concentration Range: (0,010 – 100) mg/l Continuous flow analysis metod (CFA) with spectrophotometric detection","methodology_en":"Anionic surfactants (detergents) concentration Range: (0,010 – 100) mg/l Continuous flow analysis metod (CFA) with spectrophotometric detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie anionowych substancji powierzchniowo-czynnych (detergenty/surfaktanty anionowe) Zakres (0,010 - 100) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną Anionic surfactants (detergents) concentration Range: (0,010 – 100) mg/l Continuous flow analysis metod (CFA) with spectrophotometric detection","reference":"PN-EN ISO 16265:2012","norm_bases":["PN-EN ISO 16265:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Stężenie anionowych substancji powierzchniowo-czynnych (detergenty/surfaktanty anionowe) Zakres (0,010 - 100) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną Anionic surfactants (detergents) concentration Range: (0,010 – 100) mg/l Continuous flow analysis metod (CFA) with spectrophotometric detection PN-EN ISO 16265:2012 Woda, scieki Water, sewage Stezenie anionowych substancji powierzchniowo-czynnych (detergenty/surfaktanty anionowe) Zakres (0,010 - 100) mg/l Metoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna Anionic surfactants (detergents) concentration Range: (0,010 – 100) mg/l Continuous flow analysis metod (CFA) with spectrophotometric detection PN-EN ISO 16265:2012","categories":["water"],"row_index":303,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Anionic surfactants (detergents) concentration Range: (0,010 – 100) mg/l Continuous flow analysis metod (CFA) with spectrophotometric detection PN-EN ISO 16265:2012","search_zh":"水、废水 PN-EN ISO 16265:2012","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250bcc","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Stężenie Cr(VI) Zakres: (0,010 – 50) mg/l Metoda spektrofotometryczna Stężenie Cr(III) (z obliczeń) Cr(VI) concentration Range: (0,010 – 50) mg/l Spectrophotometric method Cr(III) concentration (from calculations)","methodology_en":"Cr(VI) concentration Range: (0,010 – 50) mg/l Spectrophotometric method Cr(III) concentration (calculated) Cr(VI) concentration Range: (0,010 – 50) mg/l Spectrophotometric method Cr(III) concentration (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie Cr(VI) Zakres: (0,010 – 50) mg/l Metoda spektrofotometryczna Stężenie Cr(III) (z obliczeń) Cr(VI) concentration Range: (0,010 – 50) mg/l Spectrophotometric method Cr(III) concentration (from calculations)","reference":"PN-77/C-04604.08 SO-4/ZLGIG/PB.07.93 ed. 1 z dn. 01.08.2025 PN-77/C-04604.08 SO-4/ZLGIG/PB.07.93 ed. 1st of 01/08/2025","norm_bases":["PN-77/C-04604.08 SO-4/ZLGIG/PB.07.93 ed. 1 z dn. 01.08.2025 PN-77/C-04604.08 SO-4/ZLGIG/PB.07.93 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Stężenie Cr(VI) Zakres: (0,010 – 50) mg/l Metoda spektrofotometryczna Stężenie Cr(III) (z obliczeń) Cr(VI) concentration Range: (0,010 – 50) mg/l Spectrophotometric method Cr(III) concentration (from calculations) PN-77/C-04604.08 SO-4/ZLGIG/PB.07.93 ed. 1 z dn. 01.08.2025 PN-77/C-04604.08 SO-4/ZLGIG/PB.07.93 ed. 1st of 01/08/2025 Woda, scieki Water, sewage Stezenie Cr(VI) Zakres: (0,010 – 50) mg/l Metoda spektrofotometryczna Stezenie Cr(III) (z obliczen) Cr(VI) concentration Range: (0,010 – 50) mg/l Spectrophotometric method Cr(III) concentration (from calculations) PN-77/C-04604.08 SO-4/ZLGIG/PB.07.93 ed. 1 z dn. 01.08.2025 PN-77/C-04604.08 SO-4/ZLGIG/PB.07.93 ed. 1st of 01/08/2025","categories":["water"],"row_index":304,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Cr(VI) concentration Range: (0,010 – 50) mg/l Spectrophotometric method Cr(III) concentration (calculated) Cr(VI) concentration Range: (0,010 – 50) mg/l Spectrophotometric method Cr(III) concentration (from calculations) PN-77/C-04604.08 SO-4/ZLGIG/PB.07.93 ed. 1 z dn. 01.08.2025 PN-77/C-04604.08 SO-4/ZLGIG/PB.07.93 ed. 1st of 01/08/2025","search_zh":"水、废水 PN-77/C-04604.08 SO-4/ZLGIG/PB.07.93 ed. 1 z dn. 01.08.2025 PN-77/C-04604.08 SO-4/ZLGIG/PB.07.93 ed. 1st of 01/08/2025","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250bcd","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Indeks nadmanganianowy Zakres: (0,50 – 100) mg/l O 2 Metoda miareczkowa Permanganate index Range: (0,50 – 100) mg/l O 2 Titrimetric method","methodology_en":"Permanganate index Range: (0,50 – 100) mg/l O 2 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy Zakres: (0,50 – 100) mg/l O 2 Metoda miareczkowa Permanganate index Range: (0,50 – 100) mg/l O 2 Titrimetric method","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Indeks nadmanganianowy Zakres: (0,50 – 100) mg/l O 2 Metoda miareczkowa Permanganate index Range: (0,50 – 100) mg/l O 2 Titrimetric method PN-EN ISO 8467:2001 Woda, scieki Water, sewage Indeks nadmanganianowy Zakres: (0,50 – 100) mg/l O 2 Metoda miareczkowa Permanganate index Range: (0,50 – 100) mg/l O 2 Titrimetric method PN-EN ISO 8467:2001","categories":["water"],"row_index":305,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Permanganate index Range: (0,50 – 100) mg/l O 2 Titrimetric method PN-EN ISO 8467:2001","search_zh":"水、废水 PN-EN ISO 8467:2001","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250bce","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Stężenie: - ogólnego węgla organicznego (OWO) - rozpuszczonego węgla organicznego (RWO) Zakres: (0,50 – 2500) mg/l C Metoda wysokotemperaturowego spalania z detekcją IR Concentration: - total organic carbon (TOC) - dissolved organic carbon (DOC) Range: (0,50 – 2500) mg/l C High temp. combustion method with IR detection","methodology_en":"Concentration: - total organic carbon (TOC) - dissolved organic carbon (DOC) Range: (0,50 – 2500) mg/l C High temp. combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie: - ogólnego węgla organicznego (OWO) - rozpuszczonego węgla organicznego (RWO) Zakres: (0,50 – 2500) mg/l C Metoda wysokotemperaturowego spalania z detekcją IR Concentration: - total organic carbon (TOC) - dissolved organic carbon (DOC) Range: (0,50 – 2500) mg/l C High temp. combustion method with IR detection","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Stężenie: - ogólnego węgla organicznego (OWO) - rozpuszczonego węgla organicznego (RWO) Zakres: (0,50 – 2500) mg/l C Metoda wysokotemperaturowego spalania z detekcją IR Concentration: - total organic carbon (TOC) - dissolved organic carbon (DOC) Range: (0,50 – 2500) mg/l C High temp. combustion method with IR detection PN-EN 1484:1999 Woda, scieki Water, sewage Stezenie: - ogolnego wegla organicznego (OWO) - rozpuszczonego wegla organicznego (RWO) Zakres: (0,50 – 2500) mg/l C Metoda wysokotemperaturowego spalania z detekcja IR Concentration: - total organic carbon (TOC) - dissolved organic carbon (DOC) Range: (0,50 – 2500) mg/l C High temp. combustion method with IR detection PN-EN 1484:1999","categories":["water"],"row_index":306,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Concentration: - total organic carbon (TOC) - dissolved organic carbon (DOC) Range: (0,50 – 2500) mg/l C High temp. combustion method with IR detection PN-EN 1484:1999","search_zh":"水、废水 PN-EN 1484:1999","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250bcf","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Stężenie azotu ogólnego Zakres: (0,50 – 2500) mg/l N Metoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną Stężenie azotu Kjeldahla oraz azotu organicznego (z obliczeń) Total nitrogen concentration Range: (0,50 – 2500) mg/l N High temp. combustion method with chemiluminescent detection Kjeldahl nitrogen concentration and organic nitrogen (from calculations)","methodology_en":"Total nitrogen concentration Range: (0,50 – 2500) mg/l N High temp. combustion method with chemiluminescent detection Kjeldahl nitrogen concentration and organic nitrogen (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego Zakres: (0,50 – 2500) mg/l N Metoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną Stężenie azotu Kjeldahla oraz azotu organicznego (z obliczeń) Total nitrogen concentration Range: (0,50 – 2500) mg/l N High temp. combustion method with chemiluminescent detection Kjeldahl nitrogen concentration and organic nitrogen (from calculations)","reference":"PN-EN ISO 20236:2025-05 SO-4/ZLGIG/PB.07.94 ed. 1 z dn. 01.08.2025 PN-EN ISO 20236:2025-05 SO-4/ZLGIG/PB.07.94 ed. 1st of 01/08/2025","norm_bases":["PN-EN ISO 20236:2025-05 SO-4/ZLGIG/PB.07.94 ed. 1 z dn. 01.08.2025 PN-EN ISO 20236:2025-05 SO-4/ZLGIG/PB.07.94 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Stężenie azotu ogólnego Zakres: (0,50 – 2500) mg/l N Metoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną Stężenie azotu Kjeldahla oraz azotu organicznego (z obliczeń) Total nitrogen concentration Range: (0,50 – 2500) mg/l N High temp. combustion method with chemiluminescent detection Kjeldahl nitrogen concentration and organic nitrogen (from calculations) PN-EN ISO 20236:2025-05 SO-4/ZLGIG/PB.07.94 ed. 1 z dn. 01.08.2025 PN-EN ISO 20236:2025-05 SO-4/ZLGIG/PB.07.94 ed. 1st of 01/08/2025 Woda, scieki Water, sewage Stezenie azotu ogolnego Zakres: (0,50 – 2500) mg/l N Metoda wysokotemperaturowego spalania z detekcja chemiluminescencyjna Stezenie azotu Kjeldahla oraz azotu organicznego (z obliczen) Total nitrogen concentration Range: (0,50 – 2500) mg/l N High temp. combustion method with chemiluminescent detection Kjeldahl nitrogen concentration and organic nitrogen (from calculations) PN-EN ISO 20236:2025-05 SO-4/ZLGIG/PB.07.94 ed. 1 z dn. 01.08.2025 PN-EN ISO 20236:2025-05 SO-4/ZLGIG/PB.07.94 ed. 1st of 01/08/2025","categories":["water"],"row_index":307,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Total nitrogen concentration Range: (0,50 – 2500) mg/l N High temp. combustion method with chemiluminescent detection Kjeldahl nitrogen concentration and organic nitrogen (from calculations) PN-EN ISO 20236:2025-05 SO-4/ZLGIG/PB.07.94 ed. 1 z dn. 01.08.2025 PN-EN ISO 20236:2025-05 SO-4/ZLGIG/PB.07.94 ed. 1st of 01/08/2025","search_zh":"水、废水 PN-EN ISO 20236:2025-05 SO-4/ZLGIG/PB.07.94 ed. 1 z dn. 01.08.2025 PN-EN ISO 20236:2025-05 SO-4/ZLGIG/PB.07.94 ed. 1st of 01/08/2025","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250bd0","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Stężenie cyjanków wolnych, ogólnych Zakres: (0,0020 – 1000) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną Stężenie cyjanków związanych (z obliczeń) Free cyanide and total cyanide concentration Range: (0,0020 – 1000) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection Bound cyanide concentration (from calculations)","methodology_en":"Free cyanide and total cyanide concentration Range: (0,0020 – 1000) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection Bound cyanide concentration (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie cyjanków wolnych, ogólnych Zakres: (0,0020 – 1000) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną Stężenie cyjanków związanych (z obliczeń) Free cyanide and total cyanide concentration Range: (0,0020 – 1000) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection Bound cyanide concentration (from calculations)","reference":"PN-EN ISO 14403-2:2012 SO-4/ZLGIG/PB.07.90 ed. 1 z dn. 01.08.2025 PN-EN ISO 14403-2:2012 SO-4/ZLGIG/PB.07.90 ed. 1st of 01/08/2025","norm_bases":["PN-EN ISO 14403-2:2012 SO-4/ZLGIG/PB.07.90 ed. 1 z dn. 01.08.2025 PN-EN ISO 14403-2:2012 SO-4/ZLGIG/PB.07.90 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Stężenie cyjanków wolnych, ogólnych Zakres: (0,0020 – 1000) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną Stężenie cyjanków związanych (z obliczeń) Free cyanide and total cyanide concentration Range: (0,0020 – 1000) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection Bound cyanide concentration (from calculations) PN-EN ISO 14403-2:2012 SO-4/ZLGIG/PB.07.90 ed. 1 z dn. 01.08.2025 PN-EN ISO 14403-2:2012 SO-4/ZLGIG/PB.07.90 ed. 1st of 01/08/2025 Woda, scieki Water, sewage Stezenie cyjankow wolnych, ogolnych Zakres: (0,0020 – 1000) mg/l Metoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna Stezenie cyjankow zwiazanych (z obliczen) Free cyanide and total cyanide concentration Range: (0,0020 – 1000) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection Bound cyanide concentration (from calculations) PN-EN ISO 14403-2:2012 SO-4/ZLGIG/PB.07.90 ed. 1 z dn. 01.08.2025 PN-EN ISO 14403-2:2012 SO-4/ZLGIG/PB.07.90 ed. 1st of 01/08/2025","categories":["water"],"row_index":308,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Free cyanide and total cyanide concentration Range: (0,0020 – 1000) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection Bound cyanide concentration (from calculations) PN-EN ISO 14403-2:2012 SO-4/ZLGIG/PB.07.90 ed. 1 z dn. 01.08.2025 PN-EN ISO 14403-2:2012 SO-4/ZLGIG/PB.07.90 ed. 1st of 01/08/2025","search_zh":"水、废水 PN-EN ISO 14403-2:2012 SO-4/ZLGIG/PB.07.90 ed. 1 z dn. 01.08.2025 PN-EN ISO 14403-2:2012 SO-4/ZLGIG/PB.07.90 ed. 1st of 01/08/2025","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250bd1","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Indeks fenolowy Zakres: (0,0010 – 1000) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną Phenol index Range: (0,0010 – 1000) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection","methodology_en":"Phenol index Range: (0,0010 – 1000) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indeks fenolowy Zakres: (0,0010 – 1000) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną Phenol index Range: (0,0010 – 1000) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection","reference":"PN-EN ISO 14402:2004 pkt 4 PN-EN ISO 14402:2004 pt 4","norm_bases":["PN-EN ISO 14402:2004 pkt 4 PN-EN ISO 14402:2004 pt 4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Indeks fenolowy Zakres: (0,0010 – 1000) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną Phenol index Range: (0,0010 – 1000) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection PN-EN ISO 14402:2004 pkt 4 PN-EN ISO 14402:2004 pt 4 Woda, scieki Water, sewage Indeks fenolowy Zakres: (0,0010 – 1000) mg/l Metoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna Phenol index Range: (0,0010 – 1000) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection PN-EN ISO 14402:2004 pkt 4 PN-EN ISO 14402:2004 pt 4","categories":["water"],"row_index":309,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Phenol index Range: (0,0010 – 1000) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection PN-EN ISO 14402:2004 pkt 4 PN-EN ISO 14402:2004 pt 4","search_zh":"水、废水 PN-EN ISO 14402:2004 pkt 4 PN-EN ISO 14402:2004 pt 4","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250bd2","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Stężenie anionów Zakres: chlorki (0,0080 – 5000) mmol/l (0,28 – 177300) mg/l siarczany (0,0020 – 208) mmol/l r (0,10 – 10000) mg/l bromki (0,00025 – 6,26) mmol/l (0,020 – 500) mg/l fluorki (0,00052 – 26,3) mmol/l (0,010 – 500) mg/l azotany (0,00030 – 8,10) mmol/l (0,020 – 500) mg/l azot azotanowy(0,0045 – 113) mg/l azotyny (0,0011 – 2,17) mmol/l (0,050 – 100) mg/l azot azotynowy(0,015 – 30,4) mg/l fosforany (0,0032 – 3,79) mmol/l r (0,10 – 120) mg/l jodki (0,0024 – 1,97) mmol/l (0,30 – 250) mg/l rodanki (0,50 – 100) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","methodology_en":"Anion concentrations Range: chlorides (0,0080 – 5000) mmol/l (0,28 – 177300) mg/l sulfates (0,0020 – 208) mmol/l r (0,10 – 10000) mg/l bromides (0,00025 – 6,26) mmol/l (0,020 – 500) mg/l fluorides (0,00052 – 26,3) mmol/l (0,010 – 500) mg/l nitrates (0,00030 – 8,10) mmol/l (0,020 – 500) mg/l nitrate nitrogen(0,0045 – 113) mg/l nitrites (0,0011 – 2,17) mmol/l (0,050 – 100) mg/l nitrite nitrogen(0,015 – 30,4) mg/l phosphates (0,0032 – 3,79) mmol/l r (0,10 – 120) mg/l iodides (0,0024 – 1,97) mmol/l (0,30 – 250) mg/l thiocyanates (0,50 – 100) mg/l Ion chromatography with conductometric detection (IC-CD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie anionów Zakres: chlorki (0,0080 – 5000) mmol/l (0,28 – 177300) mg/l siarczany (0,0020 – 208) mmol/l r (0,10 – 10000) mg/l bromki (0,00025 – 6,26) mmol/l (0,020 – 500) mg/l fluorki (0,00052 – 26,3) mmol/l (0,010 – 500) mg/l azotany (0,00030 – 8,10) mmol/l (0,020 – 500) mg/l azot azotanowy(0,0045 – 113) mg/l azotyny (0,0011 – 2,17) mmol/l (0,050 – 100) mg/l azot azotynowy(0,015 – 30,4) mg/l fosforany (0,0032 – 3,79) mmol/l r (0,10 – 120) mg/l jodki (0,0024 – 1,97) mmol/l (0,30 – 250) mg/l rodanki (0,50 – 100) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012 PN-EN ISO 10304-3:2001","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012 PN-EN ISO 10304-3:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Stężenie anionów Zakres: chlorki (0,0080 – 5000) mmol/l (0,28 – 177300) mg/l siarczany (0,0020 – 208) mmol/l r (0,10 – 10000) mg/l bromki (0,00025 – 6,26) mmol/l (0,020 – 500) mg/l fluorki (0,00052 – 26,3) mmol/l (0,010 – 500) mg/l azotany (0,00030 – 8,10) mmol/l (0,020 – 500) mg/l azot azotanowy(0,0045 – 113) mg/l azotyny (0,0011 – 2,17) mmol/l (0,050 – 100) mg/l azot azotynowy(0,015 – 30,4) mg/l fosforany (0,0032 – 3,79) mmol/l r (0,10 – 120) mg/l jodki (0,0024 – 1,97) mmol/l (0,30 – 250) mg/l rodanki (0,50 – 100) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 PN-EN ISO 10304-3:2001 Woda, scieki Water, sewage Stezenie anionow Zakres: chlorki (0,0080 – 5000) mmol/l (0,28 – 177300) mg/l siarczany (0,0020 – 208) mmol/l r (0,10 – 10000) mg/l bromki (0,00025 – 6,26) mmol/l (0,020 – 500) mg/l fluorki (0,00052 – 26,3) mmol/l (0,010 – 500) mg/l azotany (0,00030 – 8,10) mmol/l (0,020 – 500) mg/l azot azotanowy(0,0045 – 113) mg/l azotyny (0,0011 – 2,17) mmol/l (0,050 – 100) mg/l azot azotynowy(0,015 – 30,4) mg/l fosforany (0,0032 – 3,79) mmol/l r (0,10 – 120) mg/l jodki (0,0024 – 1,97) mmol/l (0,30 – 250) mg/l rodanki (0,50 – 100) mg/l Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 PN-EN ISO 10304-3:2001","categories":["water"],"row_index":310,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Anion concentrations Range: chlorides (0,0080 – 5000) mmol/l (0,28 – 177300) mg/l sulfates (0,0020 – 208) mmol/l r (0,10 – 10000) mg/l bromides (0,00025 – 6,26) mmol/l (0,020 – 500) mg/l fluorides (0,00052 – 26,3) mmol/l (0,010 – 500) mg/l nitrates (0,00030 – 8,10) mmol/l (0,020 – 500) mg/l nitrate nitrogen(0,0045 – 113) mg/l nitrites (0,0011 – 2,17) mmol/l (0,050 – 100) mg/l nitrite nitrogen(0,015 – 30,4) mg/l phosphates (0,0032 – 3,79) mmol/l r (0,10 – 120) mg/l iodides (0,0024 – 1,97) mmol/l (0,30 – 250) mg/l thiocyanates (0,50 – 100) mg/l Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 PN-EN ISO 10304-3:2001","search_zh":"水、废水 PN-EN ISO 10304-1:2009+AC:2012 PN-EN ISO 10304-3:2001","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250bd3","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Anions concentration Range: chloride (0,0080 – 5000) mmol/l (0,28 – 177300) mg/l sulfate (0,0020 – 208) mmol/l r (0,10 – 10000) mg/l bromide (0,00025 – 6,26) mmol/l (0,020 – 500) mg/l fluoride (0,00052 – 26,3) mmol/l (0,010 – 500) mg/l nitrate (0,00030 – 8,10) mmol/l (0,020 – 500) mg/l nitrate nitrogen (0,0045 – 113) mg/l nitrite (0,0011 – 2,17) mmol/l (0,050 – 100) mg/l nitrite nitrogen (0,015 – 30,4) mg/l phosphate (0,0032 – 3,79) mmol/l r (0,10 – 120) mg/l iodide (0,0024 – 1,97) mmol/l (0,30 – 250) mg/l thiocyanate (0,50 – 100) mg/l Ion chromatography method with conductometric detection (IC-CD)","methodology_en":"Anions concentration Range: chloride (0,0080 – 5000) mmol/l (0,28 – 177300) mg/l sulfate (0,0020 – 208) mmol/l r (0,10 – 10000) mg/l bromide (0,00025 – 6,26) mmol/l (0,020 – 500) mg/l fluoride (0,00052 – 26,3) mmol/l (0,010 – 500) mg/l nitrate (0,00030 – 8,10) mmol/l (0,020 – 500) mg/l nitrate nitrogen (0,0045 – 113) mg/l nitrite (0,0011 – 2,17) mmol/l (0,050 – 100) mg/l nitrite nitrogen (0,015 – 30,4) mg/l phosphate (0,0032 – 3,79) mmol/l r (0,10 – 120) mg/l iodide (0,0024 – 1,97) mmol/l (0,30 – 250) mg/l thiocyanate (0,50 – 100) mg/l Ion chromatography method with conductometric detection (IC-CD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Anions concentration Range: chloride (0,0080 – 5000) mmol/l (0,28 – 177300) mg/l sulfate (0,0020 – 208) mmol/l r (0,10 – 10000) mg/l bromide (0,00025 – 6,26) mmol/l (0,020 – 500) mg/l fluoride (0,00052 – 26,3) mmol/l (0,010 – 500) mg/l nitrate (0,00030 – 8,10) mmol/l (0,020 – 500) mg/l nitrate nitrogen (0,0045 – 113) mg/l nitrite (0,0011 – 2,17) mmol/l (0,050 – 100) mg/l nitrite nitrogen (0,015 – 30,4) mg/l phosphate (0,0032 – 3,79) mmol/l r (0,10 – 120) mg/l iodide (0,0024 – 1,97) mmol/l (0,30 – 250) mg/l thiocyanate (0,50 – 100) mg/l Ion chromatography method with conductometric detection (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012 PN-EN ISO 10304-3:2001","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012 PN-EN ISO 10304-3:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Anions concentration Range: chloride (0,0080 – 5000) mmol/l (0,28 – 177300) mg/l sulfate (0,0020 – 208) mmol/l r (0,10 – 10000) mg/l bromide (0,00025 – 6,26) mmol/l (0,020 – 500) mg/l fluoride (0,00052 – 26,3) mmol/l (0,010 – 500) mg/l nitrate (0,00030 – 8,10) mmol/l (0,020 – 500) mg/l nitrate nitrogen (0,0045 – 113) mg/l nitrite (0,0011 – 2,17) mmol/l (0,050 – 100) mg/l nitrite nitrogen (0,015 – 30,4) mg/l phosphate (0,0032 – 3,79) mmol/l r (0,10 – 120) mg/l iodide (0,0024 – 1,97) mmol/l (0,30 – 250) mg/l thiocyanate (0,50 – 100) mg/l Ion chromatography method with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 PN-EN ISO 10304-3:2001 Woda, scieki Water, sewage Anions concentration Range: chloride (0,0080 – 5000) mmol/l (0,28 – 177300) mg/l sulfate (0,0020 – 208) mmol/l r (0,10 – 10000) mg/l bromide (0,00025 – 6,26) mmol/l (0,020 – 500) mg/l fluoride (0,00052 – 26,3) mmol/l (0,010 – 500) mg/l nitrate (0,00030 – 8,10) mmol/l (0,020 – 500) mg/l nitrate nitrogen (0,0045 – 113) mg/l nitrite (0,0011 – 2,17) mmol/l (0,050 – 100) mg/l nitrite nitrogen (0,015 – 30,4) mg/l phosphate (0,0032 – 3,79) mmol/l r (0,10 – 120) mg/l iodide (0,0024 – 1,97) mmol/l (0,30 – 250) mg/l thiocyanate (0,50 – 100) mg/l Ion chromatography method with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 PN-EN ISO 10304-3:2001","categories":["water"],"row_index":311,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Anions concentration Range: chloride (0,0080 – 5000) mmol/l (0,28 – 177300) mg/l sulfate (0,0020 – 208) mmol/l r (0,10 – 10000) mg/l bromide (0,00025 – 6,26) mmol/l (0,020 – 500) mg/l fluoride (0,00052 – 26,3) mmol/l (0,010 – 500) mg/l nitrate (0,00030 – 8,10) mmol/l (0,020 – 500) mg/l nitrate nitrogen (0,0045 – 113) mg/l nitrite (0,0011 – 2,17) mmol/l (0,050 – 100) mg/l nitrite nitrogen (0,015 – 30,4) mg/l phosphate (0,0032 – 3,79) mmol/l r (0,10 – 120) mg/l iodide (0,0024 – 1,97) mmol/l (0,30 – 250) mg/l thiocyanate (0,50 – 100) mg/l Ion chromatography method with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 PN-EN ISO 10304-3:2001","search_zh":"水、废水 PN-EN ISO 10304-1:2009+AC:2012 PN-EN ISO 10304-3:2001","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250bd4","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Adsorbowalne, organicznie związane chlorowce (AOX) Zakres: (0,10 – 5,0) mg/l Cl (100 – 5000) µg/l Cl Metoda miareczkowania mikrokulometrycznego Adsorbable organically bound halogens (AOX) Range: (0,10 – 5,0) mg/l Cl (100 – 5000) µg/l Cl Microcoulometric titration method","methodology_en":"Adsorbable organically bound halogens (AOX) Range: (0,10 – 5,0) mg/l Cl (100 – 5000) µg/l Cl Microcoulometric titration method Adsorbable organically bound halogens (AOX) Range: (0,10 – 5,0) mg/l Cl (100 – 5000) µg/l Cl Microcoulometric titration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Adsorbowalne, organicznie związane chlorowce (AOX) Zakres: (0,10 – 5,0) mg/l Cl (100 – 5000) µg/l Cl Metoda miareczkowania mikrokulometrycznego Adsorbable organically bound halogens (AOX) Range: (0,10 – 5,0) mg/l Cl (100 – 5000) µg/l Cl Microcoulometric titration method","reference":"PN-EN ISO 9562:2007","norm_bases":["PN-EN ISO 9562:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Adsorbowalne, organicznie związane chlorowce (AOX) Zakres: (0,10 – 5,0) mg/l Cl (100 – 5000) µg/l Cl Metoda miareczkowania mikrokulometrycznego Adsorbable organically bound halogens (AOX) Range: (0,10 – 5,0) mg/l Cl (100 – 5000) µg/l Cl Microcoulometric titration method PN-EN ISO 9562:2007 Woda, scieki Water, sewage Adsorbowalne, organicznie zwiazane chlorowce (AOX) Zakres: (0,10 – 5,0) mg/l Cl (100 – 5000) µg/l Cl Metoda miareczkowania mikrokulometrycznego Adsorbable organically bound halogens (AOX) Range: (0,10 – 5,0) mg/l Cl (100 – 5000) µg/l Cl Microcoulometric titration method PN-EN ISO 9562:2007","categories":["water"],"row_index":312,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Adsorbable organically bound halogens (AOX) Range: (0,10 – 5,0) mg/l Cl (100 – 5000) µg/l Cl Microcoulometric titration method Adsorbable organically bound halogens (AOX) Range: (0,10 – 5,0) mg/l Cl (100 – 5000) µg/l Cl Microcoulometric titration method PN-EN ISO 9562:2007","search_zh":"水、废水 PN-EN ISO 9562:2007","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250bd5","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Zawiesiny Zakres: (2,0 - 10000) mg/l Metoda wagowa Total suspended solids (TSS) Range: (2,0 - 10000) mg/l Gravimetric method","methodology_en":"Total suspended solids (TSS) Range: (2,0 - 10000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny Zakres: (2,0 - 10000) mg/l Metoda wagowa Total suspended solids (TSS) Range: (2,0 - 10000) mg/l Gravimetric method","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Zawiesiny Zakres: (2,0 - 10000) mg/l Metoda wagowa Total suspended solids (TSS) Range: (2,0 - 10000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007 Woda, scieki Water, sewage Zawiesiny Zakres: (2,0 - 10000) mg/l Metoda wagowa Total suspended solids (TSS) Range: (2,0 - 10000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":313,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Total suspended solids (TSS) Range: (2,0 - 10000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007","search_zh":"水、废水 PN-EN 872:2007+Ap1:2007","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250bd6","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Mętność Zakres: (0,20 – 400) NTU Metoda nefelometryczna Turbidity Range: (0,20 – 400) NTU Nephelometric method","methodology_en":"Turbidity Range: (0,20 – 400) NTU Nephelometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Mętność Zakres: (0,20 – 400) NTU Metoda nefelometryczna Turbidity Range: (0,20 – 400) NTU Nephelometric method","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Mętność Zakres: (0,20 – 400) NTU Metoda nefelometryczna Turbidity Range: (0,20 – 400) NTU Nephelometric method PN-EN ISO 7027-1:2016-09 Woda, scieki Water, sewage Metnosc Zakres: (0,20 – 400) NTU Metoda nefelometryczna Turbidity Range: (0,20 – 400) NTU Nephelometric method PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":314,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Turbidity Range: (0,20 – 400) NTU Nephelometric method PN-EN ISO 7027-1:2016-09","search_zh":"水、废水 PN-EN ISO 7027-1:2016-09","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250bd7","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Barwa Zakres: (2 – 1500) mg/l Pt Metoda spektrofotometryczna Color Range: (2 – 1500) mg/l Pt Spectrophotometric method","methodology_en":"Color Range: (2 – 1500) mg/l Pt Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Barwa Zakres: (2 – 1500) mg/l Pt Metoda spektrofotometryczna Color Range: (2 – 1500) mg/l Pt Spectrophotometric method","reference":"PN-EN ISO 7887:2012+Ap1:2015-06 metoda C PN-EN ISO 7887:2012+Ap1:2015-06 method C","norm_bases":["PN-EN ISO 7887:2012+Ap1:2015-06 metoda C PN-EN ISO 7887:2012+Ap1:2015-06 method C"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Barwa Zakres: (2 – 1500) mg/l Pt Metoda spektrofotometryczna Color Range: (2 – 1500) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012+Ap1:2015-06 metoda C PN-EN ISO 7887:2012+Ap1:2015-06 method C Woda, scieki Water, sewage Barwa Zakres: (2 – 1500) mg/l Pt Metoda spektrofotometryczna Color Range: (2 – 1500) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012+Ap1:2015-06 metoda C PN-EN ISO 7887:2012+Ap1:2015-06 method C","categories":["water"],"row_index":315,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Color Range: (2 – 1500) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012+Ap1:2015-06 metoda C PN-EN ISO 7887:2012+Ap1:2015-06 method C","search_zh":"水、废水 PN-EN ISO 7887:2012+Ap1:2015-06 metoda C PN-EN ISO 7887:2012+Ap1:2015-06 method C","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250bd8","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Ekstrakt eterowy Zakres: (2,5 – 1000) mg/l Metoda wagowa Ether extract Range: (2,5 – 1000) mg/l Gravimetric method","methodology_en":"Ether extract Range: (2,5 – 1000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ekstrakt eterowy Zakres: (2,5 – 1000) mg/l Metoda wagowa Ether extract Range: (2,5 – 1000) mg/l Gravimetric method","reference":"SO-4/ZLGIG/PB.07.50 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.07.50 ed. 1st of 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.07.50 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.07.50 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Ekstrakt eterowy Zakres: (2,5 – 1000) mg/l Metoda wagowa Ether extract Range: (2,5 – 1000) mg/l Gravimetric method SO-4/ZLGIG/PB.07.50 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.07.50 ed. 1st of 01/08/2025 Woda, scieki Water, sewage Ekstrakt eterowy Zakres: (2,5 – 1000) mg/l Metoda wagowa Ether extract Range: (2,5 – 1000) mg/l Gravimetric method SO-4/ZLGIG/PB.07.50 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.07.50 ed. 1st of 01/08/2025","categories":["water"],"row_index":316,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Ether extract Range: (2,5 – 1000) mg/l Gravimetric method SO-4/ZLGIG/PB.07.50 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.07.50 ed. 1st of 01/08/2025","search_zh":"水、废水 SO-4/ZLGIG/PB.07.50 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.07.50 ed. 1st of 01/08/2025","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250bd9","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Stężenie jonu amonowego Zakres: (0,020 – 1000) mg/l (0,0011 – 56) mmol/l Stężenie azotu amonowego Zakres: (0,016 – 777) mg/l Metoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną Ammonium ion concentration Range: (0,020 – 1000) mg/l (0,0011 – 56) mmol/l Ammonium nitrogen concentration Range: (0,016 – 777) mg/l Flow injection analysis method (FIA) with spectrophotometric detection","methodology_en":"Ammonium ion concentration Range: (0,020 – 1000) mg/l (0,0011 – 56) mmol/l Ammonium nitrogen concentration Range: (0,016 – 777) mg/l Flow injection analysis method (FIA) with spectrophotometric detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego Zakres: (0,020 – 1000) mg/l (0,0011 – 56) mmol/l Stężenie azotu amonowego Zakres: (0,016 – 777) mg/l Metoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną Ammonium ion concentration Range: (0,020 – 1000) mg/l (0,0011 – 56) mmol/l Ammonium nitrogen concentration Range: (0,016 – 777) mg/l Flow injection analysis method (FIA) with spectrophotometric detection","reference":"PN-EN ISO 11732:2007","norm_bases":["PN-EN ISO 11732:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Stężenie jonu amonowego Zakres: (0,020 – 1000) mg/l (0,0011 – 56) mmol/l Stężenie azotu amonowego Zakres: (0,016 – 777) mg/l Metoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną Ammonium ion concentration Range: (0,020 – 1000) mg/l (0,0011 – 56) mmol/l Ammonium nitrogen concentration Range: (0,016 – 777) mg/l Flow injection analysis method (FIA) with spectrophotometric detection PN-EN ISO 11732:2007 Woda, scieki Water, sewage Stezenie jonu amonowego Zakres: (0,020 – 1000) mg/l (0,0011 – 56) mmol/l Stezenie azotu amonowego Zakres: (0,016 – 777) mg/l Metoda wstrzykowej analizy przeplywowej (FIA) z detekcja spektrofotometryczna Ammonium ion concentration Range: (0,020 – 1000) mg/l (0,0011 – 56) mmol/l Ammonium nitrogen concentration Range: (0,016 – 777) mg/l Flow injection analysis method (FIA) with spectrophotometric detection PN-EN ISO 11732:2007","categories":["water"],"row_index":317,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Ammonium ion concentration Range: (0,020 – 1000) mg/l (0,0011 – 56) mmol/l Ammonium nitrogen concentration Range: (0,016 – 777) mg/l Flow injection analysis method (FIA) with spectrophotometric detection PN-EN ISO 11732:2007","search_zh":"水、废水 PN-EN ISO 11732:2007","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250bda","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Stężenie siarczków Zakres: (0,020 – 500) mg/l Metoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną Sulfide concentration Range: (0,020 – 500) mg/l Flow injection analysis method (FIA) with spectrophotometric detection","methodology_en":"Sulfide concentration Range: (0,020 – 500) mg/l Flow injection analysis method (FIA) with spectrophotometric detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie siarczków Zakres: (0,020 – 500) mg/l Metoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną Sulfide concentration Range: (0,020 – 500) mg/l Flow injection analysis method (FIA) with spectrophotometric detection","reference":"SO-4/ZLGIG/PB.07.51 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.07.51 ed. 1st of 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.07.51 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.07.51 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Stężenie siarczków Zakres: (0,020 – 500) mg/l Metoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną Sulfide concentration Range: (0,020 – 500) mg/l Flow injection analysis method (FIA) with spectrophotometric detection SO-4/ZLGIG/PB.07.51 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.07.51 ed. 1st of 01/08/2025 Woda, scieki Water, sewage Stezenie siarczkow Zakres: (0,020 – 500) mg/l Metoda wstrzykowej analizy przeplywowej (FIA) z detekcja spektrofotometryczna Sulfide concentration Range: (0,020 – 500) mg/l Flow injection analysis method (FIA) with spectrophotometric detection SO-4/ZLGIG/PB.07.51 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.07.51 ed. 1st of 01/08/2025","categories":["water"],"row_index":318,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Sulfide concentration Range: (0,020 – 500) mg/l Flow injection analysis method (FIA) with spectrophotometric detection SO-4/ZLGIG/PB.07.51 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.07.51 ed. 1st of 01/08/2025","search_zh":"水、废水 SO-4/ZLGIG/PB.07.51 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.07.51 ed. 1st of 01/08/2025","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250bdb","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Stężenie siarczków Zakres: (0,010 – 500) mg/l Metoda spektrofotometryczna Sulfide concentration Range: (0,010 – 500) mg/l Spectrophotometric method","methodology_en":"Sulfide concentration Range: (0,010 – 500) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie siarczków Zakres: (0,010 – 500) mg/l Metoda spektrofotometryczna Sulfide concentration Range: (0,010 – 500) mg/l Spectrophotometric method","reference":"SO-4/ZLGIG/PB.07.39 ed. 1 z dn. 01.08.2025 na podstawie testu kuwetowego MERCK SPECTROQUANT 14779 SO-4/ZLGIG/PB.07.39 ed. 1st of 01/08/2025 based on cuvette test MERCK SPECTROQUANT 14779","norm_bases":["SO-4/ZLGIG/PB.07.39 ed. 1 z dn. 01.08.2025 na podstawie testu kuwetowego MERCK SPECTROQUANT 14779 SO-4/ZLGIG/PB.07.39 ed. 1st of 01/08/2025 based on cuvette test MERCK SPECTROQUANT 14779"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Stężenie siarczków Zakres: (0,010 – 500) mg/l Metoda spektrofotometryczna Sulfide concentration Range: (0,010 – 500) mg/l Spectrophotometric method SO-4/ZLGIG/PB.07.39 ed. 1 z dn. 01.08.2025 na podstawie testu kuwetowego MERCK SPECTROQUANT 14779 SO-4/ZLGIG/PB.07.39 ed. 1st of 01/08/2025 based on cuvette test MERCK SPECTROQUANT 14779 Woda, scieki Water, sewage Stezenie siarczkow Zakres: (0,010 – 500) mg/l Metoda spektrofotometryczna Sulfide concentration Range: (0,010 – 500) mg/l Spectrophotometric method SO-4/ZLGIG/PB.07.39 ed. 1 z dn. 01.08.2025 na podstawie testu kuwetowego MERCK SPECTROQUANT 14779 SO-4/ZLGIG/PB.07.39 ed. 1st of 01/08/2025 based on cuvette test MERCK SPECTROQUANT 14779","categories":["water"],"row_index":319,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Sulfide concentration Range: (0,010 – 500) mg/l Spectrophotometric method SO-4/ZLGIG/PB.07.39 ed. 1 z dn. 01.08.2025 na podstawie testu kuwetowego MERCK SPECTROQUANT 14779 SO-4/ZLGIG/PB.07.39 ed. 1st of 01/08/2025 based on cuvette test MERCK SPECTROQUANT 14779","search_zh":"水、废水 SO-4/ZLGIG/PB.07.39 ed. 1 z dn. 01.08.2025 na podstawie testu kuwetowego MERCK SPECTROQUANT 14779 SO-4/ZLGIG/PB.07.39 ed. 1st of 01/08/2025 based on cuvette test MERCK SPECTROQUANT 14779","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250bdc","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Stężenie siarkowodoru niezdysocjowanego (z obliczeń) Unionized hydrogen sulfide concentration (from calculations)","methodology_en":"Unionized hydrogen sulfide concentration (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie siarkowodoru niezdysocjowanego (z obliczeń) Unionized hydrogen sulfide concentration (from calculations)","reference":"SO-4/ZLGIG/PB.07.97 | PN-74/C-04566.04 SO-4/ZLGIG/PB.07.97 ed. 1 z dn. 01.08.2025 PN-74/C-04566.04","norm_bases":["SO-4/ZLGIG/PB.07.97","PN-74/C-04566.04 SO-4/ZLGIG/PB.07.97 ed. 1 z dn. 01.08.2025 PN-74/C-04566.04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Stężenie siarkowodoru niezdysocjowanego (z obliczeń) Unionized hydrogen sulfide concentration (from calculations) SO-4/ZLGIG/PB.07.97 | PN-74/C-04566.04 SO-4/ZLGIG/PB.07.97 ed. 1 z dn. 01.08.2025 PN-74/C-04566.04 Woda, scieki Water, sewage Stezenie siarkowodoru niezdysocjowanego (z obliczen) Unionized hydrogen sulfide concentration (from calculations) SO-4/ZLGIG/PB.07.97 | PN-74/C-04566.04 SO-4/ZLGIG/PB.07.97 ed. 1 z dn. 01.08.2025 PN-74/C-04566.04","categories":["water"],"row_index":320,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Unionized hydrogen sulfide concentration (from calculations) SO-4/ZLGIG/PB.07.97 | PN-74/C-04566.04 SO-4/ZLGIG/PB.07.97 ed. 1 z dn. 01.08.2025 PN-74/C-04566.04","search_zh":"水、废水 SO-4/ZLGIG/PB.07.97 | PN-74/C-04566.04 SO-4/ZLGIG/PB.07.97 ed. 1 z dn. 01.08.2025 PN-74/C-04566.04","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250bdd","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Stężenie azotu Kjeldahla Zakres: (5,0 – 1200) mg/l N Metoda miareczkowania potencjometrycznego Kjeldahl nitrogen concentration Range: (5,0 – 1200) mg/l N Potentiometric titration method","methodology_en":"Kjeldahl nitrogen concentration Range: (5,0 – 1200) mg/l N Potentiometric titration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla Zakres: (5,0 – 1200) mg/l N Metoda miareczkowania potencjometrycznego Kjeldahl nitrogen concentration Range: (5,0 – 1200) mg/l N Potentiometric titration method","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Stężenie azotu Kjeldahla Zakres: (5,0 – 1200) mg/l N Metoda miareczkowania potencjometrycznego Kjeldahl nitrogen concentration Range: (5,0 – 1200) mg/l N Potentiometric titration method PN-EN 25663:2001 Woda, scieki Water, sewage Stezenie azotu Kjeldahla Zakres: (5,0 – 1200) mg/l N Metoda miareczkowania potencjometrycznego Kjeldahl nitrogen concentration Range: (5,0 – 1200) mg/l N Potentiometric titration method PN-EN 25663:2001","categories":["water"],"row_index":321,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Kjeldahl nitrogen concentration Range: (5,0 – 1200) mg/l N Potentiometric titration method PN-EN 25663:2001","search_zh":"水、废水 PN-EN 25663:2001","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250bde","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Stężenie azotu Kjeldahla Zakres: (0,50 – 1200) mg/l N Metoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną Kjeldahl nitrogen concentration Range: (0,50 – 1200) mg/l N Flow injection analysis method (FIA) with spectrophotometric detection","methodology_en":"Kjeldahl nitrogen concentration Range: (0,50 – 1200) mg/l N Flow injection analysis method (FIA) with spectrophotometric detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla Zakres: (0,50 – 1200) mg/l N Metoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną Kjeldahl nitrogen concentration Range: (0,50 – 1200) mg/l N Flow injection analysis method (FIA) with spectrophotometric detection","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Stężenie azotu Kjeldahla Zakres: (0,50 – 1200) mg/l N Metoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną Kjeldahl nitrogen concentration Range: (0,50 – 1200) mg/l N Flow injection analysis method (FIA) with spectrophotometric detection PN-EN 25663:2001 Woda, scieki Water, sewage Stezenie azotu Kjeldahla Zakres: (0,50 – 1200) mg/l N Metoda wstrzykowej analizy przeplywowej (FIA) z detekcja spektrofotometryczna Kjeldahl nitrogen concentration Range: (0,50 – 1200) mg/l N Flow injection analysis method (FIA) with spectrophotometric detection PN-EN 25663:2001","categories":["water"],"row_index":322,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Kjeldahl nitrogen concentration Range: (0,50 – 1200) mg/l N Flow injection analysis method (FIA) with spectrophotometric detection PN-EN 25663:2001","search_zh":"水、废水 PN-EN 25663:2001","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250bdf","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Stężenie rtęci Zakres: (0,00050 – 0,10) mg/l (0,50 – 100) µg/l Metoda atomowej spektrometrii fluorescencyjnej (AFS) Mercury concentration Range: (0,00050 – 0,10) mg/l (0,50 – 100) µg/l Atomic fluorescence spectrometry method (AFS)","methodology_en":"Mercury concentration Range: (0,00050 – 0,10) mg/l (0,50 – 100) µg/l Atomic fluorescence spectrometry method (AFS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie rtęci Zakres: (0,00050 – 0,10) mg/l (0,50 – 100) µg/l Metoda atomowej spektrometrii fluorescencyjnej (AFS) Mercury concentration Range: (0,00050 – 0,10) mg/l (0,50 – 100) µg/l Atomic fluorescence spectrometry method (AFS)","reference":"PN-EN ISO 17852:2009","norm_bases":["PN-EN ISO 17852:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Stężenie rtęci Zakres: (0,00050 – 0,10) mg/l (0,50 – 100) µg/l Metoda atomowej spektrometrii fluorescencyjnej (AFS) Mercury concentration Range: (0,00050 – 0,10) mg/l (0,50 – 100) µg/l Atomic fluorescence spectrometry method (AFS) PN-EN ISO 17852:2009 Woda, scieki Water, sewage Stezenie rteci Zakres: (0,00050 – 0,10) mg/l (0,50 – 100) µg/l Metoda atomowej spektrometrii fluorescencyjnej (AFS) Mercury concentration Range: (0,00050 – 0,10) mg/l (0,50 – 100) µg/l Atomic fluorescence spectrometry method (AFS) PN-EN ISO 17852:2009","categories":["water"],"row_index":323,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Mercury concentration Range: (0,00050 – 0,10) mg/l (0,50 – 100) µg/l Atomic fluorescence spectrometry method (AFS) PN-EN ISO 17852:2009","search_zh":"水、废水 PN-EN ISO 17852:2009","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250be0","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Stężenie Fe(II) rozpuszczonego Zakres: (0,020 – 50) mg/l Metoda spektrofotometryczna Dissolved iron(II) concentration Range: (0,020 – 50) mg/l Spectrophotometric method","methodology_en":"Dissolved iron(II) concentration Range: (0,020 – 50) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie Fe(II) rozpuszczonego Zakres: (0,020 – 50) mg/l Metoda spektrofotometryczna Dissolved iron(II) concentration Range: (0,020 – 50) mg/l Spectrophotometric method","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Stężenie Fe(II) rozpuszczonego Zakres: (0,020 – 50) mg/l Metoda spektrofotometryczna Dissolved iron(II) concentration Range: (0,020 – 50) mg/l Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06 Woda, scieki Water, sewage Stezenie Fe(II) rozpuszczonego Zakres: (0,020 – 50) mg/l Metoda spektrofotometryczna Dissolved iron(II) concentration Range: (0,020 – 50) mg/l Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":324,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Dissolved iron(II) concentration Range: (0,020 – 50) mg/l Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06","search_zh":"水、废水 PN-ISO 6332:2001+Ap1:2016-06","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250be1","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, sewage","test_object_en":"Water, sewage","methodology":"Stężenie fosforanów Zakres: (0,010 – 200) mg/l PO 3- 4 Metoda spektrofotometryczna Phosphate concentration Range: (0,010 – 200) mg/l PO 3- 4 Spectrophotometric method","methodology_en":"Phosphate concentration Range: (0,010 – 200) mg/l PO 3- 4 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforanów Zakres: (0,010 – 200) mg/l PO 3- 4 Metoda spektrofotometryczna Phosphate concentration Range: (0,010 – 200) mg/l PO 3- 4 Spectrophotometric method","reference":"PN-EN ISO 6878:2006 rozdz. 4 + Ap1:2010 + Ap2:2010 PN-EN ISO 6878:2006 cl 4 + Ap1:2010 + Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 rozdz. 4 + Ap1:2010 + Ap2:2010 PN-EN ISO 6878:2006 cl 4 + Ap1:2010 + Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, sewage Stężenie fosforanów Zakres: (0,010 – 200) mg/l PO 3- 4 Metoda spektrofotometryczna Phosphate concentration Range: (0,010 – 200) mg/l PO 3- 4 Spectrophotometric method PN-EN ISO 6878:2006 rozdz. 4 + Ap1:2010 + Ap2:2010 PN-EN ISO 6878:2006 cl 4 + Ap1:2010 + Ap2:2010 Woda, scieki Water, sewage Stezenie fosforanow Zakres: (0,010 – 200) mg/l PO 3- 4 Metoda spektrofotometryczna Phosphate concentration Range: (0,010 – 200) mg/l PO 3- 4 Spectrophotometric method PN-EN ISO 6878:2006 rozdz. 4 + Ap1:2010 + Ap2:2010 PN-EN ISO 6878:2006 cl 4 + Ap1:2010 + Ap2:2010","categories":["water"],"row_index":325,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, sewage Phosphate concentration Range: (0,010 – 200) mg/l PO 3- 4 Spectrophotometric method PN-EN ISO 6878:2006 rozdz. 4 + Ap1:2010 + Ap2:2010 PN-EN ISO 6878:2006 cl 4 + Ap1:2010 + Ap2:2010","search_zh":"水、废水 PN-EN ISO 6878:2006 rozdz. 4 + Ap1:2010 + Ap2:2010 PN-EN ISO 6878:2006 cl 4 + Ap1:2010 + Ap2:2010","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250be2","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda Water","test_object_en":"Water","methodology":"Stężenie bromianów Zakres: (0,0030 – 1,0) mg/l (3,0 – 1000) µg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Bromate concentration Zakres: (0,0030 – 1,0) mg/l (3,0 – 1000) µg/l Ion chromatography method with conductometric detection (IC-CD)","methodology_en":"Bromate concentration Range: (0,0030 – 1,0) mg/l (3,0 – 1000) µg/l Ion chromatography method with conductometric detection (IC-CD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie bromianów Zakres: (0,0030 – 1,0) mg/l (3,0 – 1000) µg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Bromate concentration Zakres: (0,0030 – 1,0) mg/l (3,0 – 1000) µg/l Ion chromatography method with conductometric detection (IC-CD)","reference":"PN-EN ISO 15061:2003","norm_bases":["PN-EN ISO 15061:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Water Stężenie bromianów Zakres: (0,0030 – 1,0) mg/l (3,0 – 1000) µg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Bromate concentration Zakres: (0,0030 – 1,0) mg/l (3,0 – 1000) µg/l Ion chromatography method with conductometric detection (IC-CD) PN-EN ISO 15061:2003 Woda Water Stezenie bromianow Zakres: (0,0030 – 1,0) mg/l (3,0 – 1000) µg/l Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Bromate concentration Zakres: (0,0030 – 1,0) mg/l (3,0 – 1000) µg/l Ion chromatography method with conductometric detection (IC-CD) PN-EN ISO 15061:2003","categories":["water"],"row_index":326,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Bromate concentration Range: (0,0030 – 1,0) mg/l (3,0 – 1000) µg/l Ion chromatography method with conductometric detection (IC-CD) PN-EN ISO 15061:2003","search_zh":"水 Water PN-EN ISO 15061:2003","test_object_zh":"水 Water"},{"_id":"6a5a55ef9af9f73f38250be3","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda Water","test_object_en":"Water","methodology":"Stężenie anionów Zakres: chlorany (0,0030 – 10) mg/l (3,0 – 10000) µg/l chloryny (0,0040 – 10) mg/l (4,0 – 10000) µg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Suma chloranów i chlorynów (z obliczeń) Anions concentration Range: chlorate (0,0030 – 10) mg/l (3,0 – 10000) µg/l chlorite (0,0040 – 10) mg/l (4,0 – 10000) µg/l Ion chromatography method with conductometric detection (IC-CD) Total chlorate and chlorites (from calculations)","methodology_en":"Anions concentration Range: chlorate (0,0030 – 10) mg/l (3,0 – 10000) µg/l chlorite (0,0040 – 10) mg/l (4,0 – 10000) µg/l Ion chromatography method with conductometric detection (IC-CD) Total chlorate and chlorites (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie anionów Zakres: chlorany (0,0030 – 10) mg/l (3,0 – 10000) µg/l chloryny (0,0040 – 10) mg/l (4,0 – 10000) µg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Suma chloranów i chlorynów (z obliczeń) Anions concentration Range: chlorate (0,0030 – 10) mg/l (3,0 – 10000) µg/l chlorite (0,0040 – 10) mg/l (4,0 – 10000) µg/l Ion chromatography method with conductometric detection (IC-CD) Total chlorate and chlorites (from calculations)","reference":"PN-EN ISO 10304-4:2022-08","norm_bases":["PN-EN ISO 10304-4:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Water Stężenie anionów Zakres: chlorany (0,0030 – 10) mg/l (3,0 – 10000) µg/l chloryny (0,0040 – 10) mg/l (4,0 – 10000) µg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Suma chloranów i chlorynów (z obliczeń) Anions concentration Range: chlorate (0,0030 – 10) mg/l (3,0 – 10000) µg/l chlorite (0,0040 – 10) mg/l (4,0 – 10000) µg/l Ion chromatography method with conductometric detection (IC-CD) Total chlorate and chlorites (from calculations) PN-EN ISO 10304-4:2022-08 Woda Water Stezenie anionow Zakres: chlorany (0,0030 – 10) mg/l (3,0 – 10000) µg/l chloryny (0,0040 – 10) mg/l (4,0 – 10000) µg/l Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Suma chloranow i chlorynow (z obliczen) Anions concentration Range: chlorate (0,0030 – 10) mg/l (3,0 – 10000) µg/l chlorite (0,0040 – 10) mg/l (4,0 – 10000) µg/l Ion chromatography method with conductometric detection (IC-CD) Total chlorate and chlorites (from calculations) PN-EN ISO 10304-4:2022-08","categories":["water"],"row_index":327,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Anions concentration Range: chlorate (0,0030 – 10) mg/l (3,0 – 10000) µg/l chlorite (0,0040 – 10) mg/l (4,0 – 10000) µg/l Ion chromatography method with conductometric detection (IC-CD) Total chlorate and chlorites (from calculations) PN-EN ISO 10304-4:2022-08","search_zh":"水 Water PN-EN ISO 10304-4:2022-08","test_object_zh":"水 Water"},{"_id":"6a5a55ef9af9f73f38250be4","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda Water","test_object_en":"Water","methodology":"Stężenie dwutlenku węgla wolnego Zakres: (2,2 – 2000) mg/l Metoda miareczkowa Free carbon dioxide concentration Range: (2,2 – 2000) mg/l Titrimetric method","methodology_en":"Free carbon dioxide concentration Range: (2,2 – 2000) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie dwutlenku węgla wolnego Zakres: (2,2 – 2000) mg/l Metoda miareczkowa Free carbon dioxide concentration Range: (2,2 – 2000) mg/l Titrimetric method","reference":"PN-74/C-04547.01 pkt 2.1 PN-74/C-04547.01 pt 2.1","norm_bases":["PN-74/C-04547.01 pkt 2.1 PN-74/C-04547.01 pt 2.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Water Stężenie dwutlenku węgla wolnego Zakres: (2,2 – 2000) mg/l Metoda miareczkowa Free carbon dioxide concentration Range: (2,2 – 2000) mg/l Titrimetric method PN-74/C-04547.01 pkt 2.1 PN-74/C-04547.01 pt 2.1 Woda Water Stezenie dwutlenku wegla wolnego Zakres: (2,2 – 2000) mg/l Metoda miareczkowa Free carbon dioxide concentration Range: (2,2 – 2000) mg/l Titrimetric method PN-74/C-04547.01 pkt 2.1 PN-74/C-04547.01 pt 2.1","categories":["water"],"row_index":328,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Free carbon dioxide concentration Range: (2,2 – 2000) mg/l Titrimetric method PN-74/C-04547.01 pkt 2.1 PN-74/C-04547.01 pt 2.1","search_zh":"水 Water PN-74/C-04547.01 pkt 2.1 PN-74/C-04547.01 pt 2.1","test_object_zh":"水 Water"},{"_id":"6a5a55ef9af9f73f38250be5","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda Water","test_object_en":"Water","methodology":"Stężenie dwutlenku węgla agresywnego Zakres: (2,2 – 180) mg/l Metoda miareczkowa Agressive carbon dioxide concentration- Range: (2,2 – 180) mg/l Titrimetric method","methodology_en":"Agressive carbon dioxide concentration- Range: (2,2 – 180) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie dwutlenku węgla agresywnego Zakres: (2,2 – 180) mg/l Metoda miareczkowa Agressive carbon dioxide concentration- Range: (2,2 – 180) mg/l Titrimetric method","reference":"PN-EN 13577:2008","norm_bases":["PN-EN 13577:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Water Stężenie dwutlenku węgla agresywnego Zakres: (2,2 – 180) mg/l Metoda miareczkowa Agressive carbon dioxide concentration- Range: (2,2 – 180) mg/l Titrimetric method PN-EN 13577:2008 Woda Water Stezenie dwutlenku wegla agresywnego Zakres: (2,2 – 180) mg/l Metoda miareczkowa Agressive carbon dioxide concentration- Range: (2,2 – 180) mg/l Titrimetric method PN-EN 13577:2008","categories":["water"],"row_index":329,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Agressive carbon dioxide concentration- Range: (2,2 – 180) mg/l Titrimetric method PN-EN 13577:2008","search_zh":"水 Water PN-EN 13577:2008","test_object_zh":"水 Water"},{"_id":"6a5a55ef9af9f73f38250be6","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda Water","test_object_en":"Water","methodology":"Stężenie Cr(VI) Zakres: (0,010 – 50) mg/l Metoda spektrofotometryczna Stężenie Cr(III) (z obliczeń) Cr(VI) concentration Range: (0,010 – 50) mg/l Spectrophotometric method Cr(III) concentration (from calculations)","methodology_en":"Cr(VI) concentration Range: (0,010 – 50) mg/l Spectrophotometric method Cr(III) concentration (calculated) Cr(VI) concentration Range: (0,010 – 50) mg/l Spectrophotometric method Cr(III) concentration (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie Cr(VI) Zakres: (0,010 – 50) mg/l Metoda spektrofotometryczna Stężenie Cr(III) (z obliczeń) Cr(VI) concentration Range: (0,010 – 50) mg/l Spectrophotometric method Cr(III) concentration (from calculations)","reference":"PN-EN ISO 18412:2007 SO-4/ZLGIG/PB.07.93 ed. 1 z dn. 01.08.2025 PN-EN ISO 18412:2007 SO-4/ZLGIG/PB.07.93 ed. 1st of 01/08/2025","norm_bases":["PN-EN ISO 18412:2007 SO-4/ZLGIG/PB.07.93 ed. 1 z dn. 01.08.2025 PN-EN ISO 18412:2007 SO-4/ZLGIG/PB.07.93 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Water Stężenie Cr(VI) Zakres: (0,010 – 50) mg/l Metoda spektrofotometryczna Stężenie Cr(III) (z obliczeń) Cr(VI) concentration Range: (0,010 – 50) mg/l Spectrophotometric method Cr(III) concentration (from calculations) PN-EN ISO 18412:2007 SO-4/ZLGIG/PB.07.93 ed. 1 z dn. 01.08.2025 PN-EN ISO 18412:2007 SO-4/ZLGIG/PB.07.93 ed. 1st of 01/08/2025 Woda Water Stezenie Cr(VI) Zakres: (0,010 – 50) mg/l Metoda spektrofotometryczna Stezenie Cr(III) (z obliczen) Cr(VI) concentration Range: (0,010 – 50) mg/l Spectrophotometric method Cr(III) concentration (from calculations) PN-EN ISO 18412:2007 SO-4/ZLGIG/PB.07.93 ed. 1 z dn. 01.08.2025 PN-EN ISO 18412:2007 SO-4/ZLGIG/PB.07.93 ed. 1st of 01/08/2025","categories":["water"],"row_index":330,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Cr(VI) concentration Range: (0,010 – 50) mg/l Spectrophotometric method Cr(III) concentration (calculated) Cr(VI) concentration Range: (0,010 – 50) mg/l Spectrophotometric method Cr(III) concentration (from calculations) PN-EN ISO 18412:2007 SO-4/ZLGIG/PB.07.93 ed. 1 z dn. 01.08.2025 PN-EN ISO 18412:2007 SO-4/ZLGIG/PB.07.93 ed. 1st of 01/08/2025","search_zh":"水 Water PN-EN ISO 18412:2007 SO-4/ZLGIG/PB.07.93 ed. 1 z dn. 01.08.2025 PN-EN ISO 18412:2007 SO-4/ZLGIG/PB.07.93 ed. 1st of 01/08/2025","test_object_zh":"水 Water"},{"_id":"6a5a55ef9af9f73f38250be7","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda podziemna Underground water","test_object_en":"Underground water","methodology":"Adsorbowalne, organicznie związane chlorowce (AOX) Zakres: (0,010 – 5,0) mg/l Cl (10 – 5000) µg/l Cl Metoda miareczkowania mikrokulometrycznego Adsorbable organically bound halogens (AOX) Range: (0,010 – 5,0) mg/l Cl (10 – 5000) µg/l Cl Microcoulometric titration method","methodology_en":"Adsorbable organically bound halogens (AOX) Range: (0,010 – 5,0) mg/l Cl (10 – 5000) µg/l Cl Microcoulometric titration method Adsorbable organically bound halogens (AOX) Range: (0,010 – 5,0) mg/l Cl (10 – 5000) µg/l Cl Microcoulometric titration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Adsorbowalne, organicznie związane chlorowce (AOX) Zakres: (0,010 – 5,0) mg/l Cl (10 – 5000) µg/l Cl Metoda miareczkowania mikrokulometrycznego Adsorbable organically bound halogens (AOX) Range: (0,010 – 5,0) mg/l Cl (10 – 5000) µg/l Cl Microcoulometric titration method","reference":"PN-EN ISO 9562:2007","norm_bases":["PN-EN ISO 9562:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda podziemna Underground water Adsorbowalne, organicznie związane chlorowce (AOX) Zakres: (0,010 – 5,0) mg/l Cl (10 – 5000) µg/l Cl Metoda miareczkowania mikrokulometrycznego Adsorbable organically bound halogens (AOX) Range: (0,010 – 5,0) mg/l Cl (10 – 5000) µg/l Cl Microcoulometric titration method PN-EN ISO 9562:2007 Woda podziemna Underground water Adsorbowalne, organicznie zwiazane chlorowce (AOX) Zakres: (0,010 – 5,0) mg/l Cl (10 – 5000) µg/l Cl Metoda miareczkowania mikrokulometrycznego Adsorbable organically bound halogens (AOX) Range: (0,010 – 5,0) mg/l Cl (10 – 5000) µg/l Cl Microcoulometric titration method PN-EN ISO 9562:2007","categories":["water"],"row_index":331,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Underground water Adsorbable organically bound halogens (AOX) Range: (0,010 – 5,0) mg/l Cl (10 – 5000) µg/l Cl Microcoulometric titration method Adsorbable organically bound halogens (AOX) Range: (0,010 – 5,0) mg/l Cl (10 – 5000) µg/l Cl Microcoulometric titration method PN-EN ISO 9562:2007"},{"_id":"6a5a55ef9af9f73f38250be8","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda powierzchniowa Surface water","test_object_en":"Surface water","methodology":"Stężenie rtęci Zakres: (0,000050 – 0,10) mg/l (0,050 – 100) µg/l Metoda atomowej spektrometrii fluorescencyjnej (AFS) Mercury concentration Range: (0,000050 – 0,10) mg/l (0,050 – 100) µg/l Atomic fluorescence spectrometry method (AFS)","methodology_en":"Mercury concentration Range: (0,000050 – 0,10) mg/l (0,050 – 100) µg/l Atomic fluorescence spectrometry method (AFS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie rtęci Zakres: (0,000050 – 0,10) mg/l (0,050 – 100) µg/l Metoda atomowej spektrometrii fluorescencyjnej (AFS) Mercury concentration Range: (0,000050 – 0,10) mg/l (0,050 – 100) µg/l Atomic fluorescence spectrometry method (AFS)","reference":"PN-EN ISO 17852:2009","norm_bases":["PN-EN ISO 17852:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda powierzchniowa Surface water Stężenie rtęci Zakres: (0,000050 – 0,10) mg/l (0,050 – 100) µg/l Metoda atomowej spektrometrii fluorescencyjnej (AFS) Mercury concentration Range: (0,000050 – 0,10) mg/l (0,050 – 100) µg/l Atomic fluorescence spectrometry method (AFS) PN-EN ISO 17852:2009 Woda powierzchniowa Surface water Stezenie rteci Zakres: (0,000050 – 0,10) mg/l (0,050 – 100) µg/l Metoda atomowej spektrometrii fluorescencyjnej (AFS) Mercury concentration Range: (0,000050 – 0,10) mg/l (0,050 – 100) µg/l Atomic fluorescence spectrometry method (AFS) PN-EN ISO 17852:2009","categories":["water"],"row_index":332,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Surface water Mercury concentration Range: (0,000050 – 0,10) mg/l (0,050 – 100) µg/l Atomic fluorescence spectrometry method (AFS) PN-EN ISO 17852:2009"},{"_id":"6a5a55ef9af9f73f38250be9","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda powierzchniowa Surface water","test_object_en":"Surface water","methodology":"Stężenie pierwiastków Zakres: Cd (0,0002 – 1,00) mg/l Sb (0,0020 – 1,00) mg/l P (0,010 – 100) mg/l PO 3- og 4 (0,0003 – 3,16) mmol/l PO 3- r 4 (0,0033 – 32,6) mg/l P (0,0074 – 74,7) mg/l P O 2 5 Tl (0,002 – 1,00) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Elements concentration Range: Cd (0,0002 – 1,00) mg/l Sb (0,0020 – 1,00) mg/l P (0,010 – 100) mg/l PO 3- tot. 4 (0,0003 – 3,16) mmol/l PO 3- r 4 (0,0033 – 32,6) mg/l P (0,0074 – 74,7) mg/l P O 2 5 Tl (0,002 – 1,00) mg/l Inductively coupled plasma optical emission spectrometry method (ICP-OES)","methodology_en":"Elements concentration Range: Cd (0,0002 – 1,00) mg/l Sb (0,0020 – 1,00) mg/l P (0,010 – 100) mg/l PO 3- tot. 4 (0,0003 – 3,16) mmol/l PO 3- r 4 (0,0033 – 32,6) mg/l P (0,0074 – 74,7) mg/l P O 2 5 Tl (0,002 – 1,00) mg/l Inductively coupled plasma optical emission spectrometry method (ICP-OES)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pierwiastków Zakres: Cd (0,0002 – 1,00) mg/l Sb (0,0020 – 1,00) mg/l P (0,010 – 100) mg/l PO 3- og 4 (0,0003 – 3,16) mmol/l PO 3- r 4 (0,0033 – 32,6) mg/l P (0,0074 – 74,7) mg/l P O 2 5 Tl (0,002 – 1,00) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Elements concentration Range: Cd (0,0002 – 1,00) mg/l Sb (0,0020 – 1,00) mg/l P (0,010 – 100) mg/l PO 3- tot. 4 (0,0003 – 3,16) mmol/l PO 3- r 4 (0,0033 – 32,6) mg/l P (0,0074 – 74,7) mg/l P O 2 5 Tl (0,002 – 1,00) mg/l Inductively coupled plasma optical emission spectrometry method (ICP-OES)","reference":"PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1 z dn. 01.08.2025 PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1st of 01/08/2025","norm_bases":["PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1 z dn. 01.08.2025 PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda powierzchniowa Surface water Stężenie pierwiastków Zakres: Cd (0,0002 – 1,00) mg/l Sb (0,0020 – 1,00) mg/l P (0,010 – 100) mg/l PO 3- og 4 (0,0003 – 3,16) mmol/l PO 3- r 4 (0,0033 – 32,6) mg/l P (0,0074 – 74,7) mg/l P O 2 5 Tl (0,002 – 1,00) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Elements concentration Range: Cd (0,0002 – 1,00) mg/l Sb (0,0020 – 1,00) mg/l P (0,010 – 100) mg/l PO 3- tot. 4 (0,0003 – 3,16) mmol/l PO 3- r 4 (0,0033 – 32,6) mg/l P (0,0074 – 74,7) mg/l P O 2 5 Tl (0,002 – 1,00) mg/l Inductively coupled plasma optical emission spectrometry method (ICP-OES) PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1 z dn. 01.08.2025 PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1st of 01/08/2025 Woda powierzchniowa Surface water Stezenie pierwiastkow Zakres: Cd (0,0002 – 1,00) mg/l Sb (0,0020 – 1,00) mg/l P (0,010 – 100) mg/l PO 3- og 4 (0,0003 – 3,16) mmol/l PO 3- r 4 (0,0033 – 32,6) mg/l P (0,0074 – 74,7) mg/l P O 2 5 Tl (0,002 – 1,00) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Elements concentration Range: Cd (0,0002 – 1,00) mg/l Sb (0,0020 – 1,00) mg/l P (0,010 – 100) mg/l PO 3- tot. 4 (0,0003 – 3,16) mmol/l PO 3- r 4 (0,0033 – 32,6) mg/l P (0,0074 – 74,7) mg/l P O 2 5 Tl (0,002 – 1,00) mg/l Inductively coupled plasma optical emission spectrometry method (ICP-OES) PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1 z dn. 01.08.2025 PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1st of 01/08/2025","categories":["water","environment"],"row_index":333,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Surface water Elements concentration Range: Cd (0,0002 – 1,00) mg/l Sb (0,0020 – 1,00) mg/l P (0,010 – 100) mg/l PO 3- tot. 4 (0,0003 – 3,16) mmol/l PO 3- r 4 (0,0033 – 32,6) mg/l P (0,0074 – 74,7) mg/l P O 2 5 Tl (0,002 – 1,00) mg/l Inductively coupled plasma optical emission spectrometry method (ICP-OES) PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1 z dn. 01.08.2025 PN-EN ISO 11885:2009 SO-4/ZLGIG/PB.07.92 ed. 1st of 01/08/2025"},{"_id":"6a5a55ef9af9f73f38250bea","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06","test_object_en":"WasteO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06","methodology":"pH Zakres 2,0 – 12,0 Metoda potencjometryczna pH value Range: 2,0 – 12,0 Potentiometric method","methodology_en":"pH value Range: 2,0 – 12,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres 2,0 – 12,0 Metoda potencjometryczna pH value Range: 2,0 – 12,0 Potentiometric method","reference":"PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 10523:2012","norm_bases":["PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 pH Zakres 2,0 – 12,0 Metoda potencjometryczna pH value Range: 2,0 – 12,0 Potentiometric method PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 10523:2012 OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 pH Zakres 2,0 – 12,0 Metoda potencjometryczna pH value Range: 2,0 – 12,0 Potentiometric method PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 10523:2012","categories":["environment"],"row_index":334,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"WasteO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 pH value Range: 2,0 – 12,0 Potentiometric method PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 10523:2012"},{"_id":"6a5a55ef9af9f73f38250beb","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06","test_object_en":"WasteO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06","methodology":"Przewodność elektryczna właściwa Zakres: (10 – 250000) S/cm Metoda konduktometryczna Electrical conductivity Range: (10 – 250000) S/cm Conductometric method","methodology_en":"Electrical conductivity Range: (10 – 250000) S/cm Conductometric method Electrical conductivity Range: (10 – 250000) S/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (10 – 250000) S/cm Metoda konduktometryczna Electrical conductivity Range: (10 – 250000) S/cm Conductometric method","reference":"PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN 27888:1999","norm_bases":["PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Przewodność elektryczna właściwa Zakres: (10 – 250000) S/cm Metoda konduktometryczna Electrical conductivity Range: (10 – 250000) S/cm Conductometric method PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN 27888:1999 OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Przewodnosc elektryczna wlasciwa Zakres: (10 – 250000) S/cm Metoda konduktometryczna Electrical conductivity Range: (10 – 250000) S/cm Conductometric method PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN 27888:1999","categories":["environment"],"row_index":335,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"WasteO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Electrical conductivity Range: (10 – 250000) S/cm Conductometric method Electrical conductivity Range: (10 – 250000) S/cm Conductometric method PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN 27888:1999"},{"_id":"6a5a55ef9af9f73f38250bec","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Grunty Materiały budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates","test_object_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates","methodology":"Stężenie chlorków Zakres: (5,0 – 177300) mg/l Metoda miareczkowa Concentration of chloride Range: (5,0 – 177300) mg/l Titrimetric method","methodology_en":"Concentration of chloride Range: (5,0 – 177300) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (5,0 – 177300) mg/l Metoda miareczkowa Concentration of chloride Range: (5,0 – 177300) mg/l Titrimetric method","reference":"PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-ISO 9297:1994","norm_bases":["PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Grunty Materiały budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Stężenie chlorków Zakres: (5,0 – 177300) mg/l Metoda miareczkowa Concentration of chloride Range: (5,0 – 177300) mg/l Titrimetric method PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-ISO 9297:1994 Zuzle, popioly paleniskowe i pyly z kotlow, popioly lotne z wegla, stale odpady z wapniowych metod odsiarczania gazow odlotowych, piaski ze zloz fluidalnych, mieszaniny popiolow lotnych i odpadow stalych z wapniowych metod odsiarczania gazow odlotowych, mieszanki popiolowo-zuzlowe z mokrego odprowadzania odpadow paleniskowych Grunty Materialy budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Stezenie chlorkow Zakres: (5,0 – 177300) mg/l Metoda miareczkowa Concentration of chloride Range: (5,0 – 177300) mg/l Titrimetric method PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-ISO 9297:1994","categories":["materials","environment","construction"],"row_index":336,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Concentration of chloride Range: (5,0 – 177300) mg/l Titrimetric method PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-ISO 9297:1994","search_zh":"炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料；土体；建筑材料：矿物集料 Solid PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-ISO 9297:1994","test_object_zh":"炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料；土体；建筑材料：矿物集料 Solid"},{"_id":"6a5a55ef9af9f73f38250bed","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Grunty Materiały budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates","test_object_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates","methodology":"Stężenie chlorków Zakres: (5,0 – 177300) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Concentration of chloride Range: (5,0 – 177300) mg/l Ion chromatography method with conductometric detection (IC-CD)","methodology_en":"Concentration of chloride Range: (5,0 – 177300) mg/l Ion chromatography method with conductometric detection (IC-CD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (5,0 – 177300) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Concentration of chloride Range: (5,0 – 177300) mg/l Ion chromatography method with conductometric detection (IC-CD)","reference":"PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Grunty Materiały budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Stężenie chlorków Zakres: (5,0 – 177300) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Concentration of chloride Range: (5,0 – 177300) mg/l Ion chromatography method with conductometric detection (IC-CD) PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 10304-1:2009+AC:2012 Zuzle, popioly paleniskowe i pyly z kotlow, popioly lotne z wegla, stale odpady z wapniowych metod odsiarczania gazow odlotowych, piaski ze zloz fluidalnych, mieszaniny popiolow lotnych i odpadow stalych z wapniowych metod odsiarczania gazow odlotowych, mieszanki popiolowo-zuzlowe z mokrego odprowadzania odpadow paleniskowych Grunty Materialy budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Stezenie chlorkow Zakres: (5,0 – 177300) mg/l Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Concentration of chloride Range: (5,0 – 177300) mg/l Ion chromatography method with conductometric detection (IC-CD) PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 10304-1:2009+AC:2012","categories":["materials","environment","construction"],"row_index":337,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Concentration of chloride Range: (5,0 – 177300) mg/l Ion chromatography method with conductometric detection (IC-CD) PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 10304-1:2009+AC:2012","search_zh":"炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料；土体；建筑材料：矿物集料 Solid PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 10304-1:2009+AC:2012","test_object_zh":"炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料；土体；建筑材料：矿物集料 Solid"},{"_id":"6a5a55ef9af9f73f38250bee","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Grunty Materiały budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates","test_object_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates","methodology":"Stężenie siarczanów Zakres: (10 – 10000) mg/l Metoda wagowa Concentration of sulphate Range: (10 – 10000) mg/l Gravimetric method","methodology_en":"Concentration of sulphate Range: (10 – 10000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie siarczanów Zakres: (10 – 10000) mg/l Metoda wagowa Concentration of sulphate Range: (10 – 10000) mg/l Gravimetric method","reference":"PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-ISO 9280:2002","norm_bases":["PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Grunty Materiały budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Stężenie siarczanów Zakres: (10 – 10000) mg/l Metoda wagowa Concentration of sulphate Range: (10 – 10000) mg/l Gravimetric method PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-ISO 9280:2002 Zuzle, popioly paleniskowe i pyly z kotlow, popioly lotne z wegla, stale odpady z wapniowych metod odsiarczania gazow odlotowych, piaski ze zloz fluidalnych, mieszaniny popiolow lotnych i odpadow stalych z wapniowych metod odsiarczania gazow odlotowych, mieszanki popiolowo-zuzlowe z mokrego odprowadzania odpadow paleniskowych Grunty Materialy budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Stezenie siarczanow Zakres: (10 – 10000) mg/l Metoda wagowa Concentration of sulphate Range: (10 – 10000) mg/l Gravimetric method PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-ISO 9280:2002","categories":["materials","environment","construction"],"row_index":338,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Concentration of sulphate Range: (10 – 10000) mg/l Gravimetric method PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-ISO 9280:2002","search_zh":"炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料；土体；建筑材料：矿物集料 Solid PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-ISO 9280:2002","test_object_zh":"炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料；土体；建筑材料：矿物集料 Solid"},{"_id":"6a5a55ef9af9f73f38250bef","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Grunty Materiały budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates","test_object_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates","methodology":"Stężenie siarczanów Zakres: (1,0 – 10000) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Concentration of sulphate Range: (1,0 – 10000) mg/l Ion chromatography method with conductometric detection (IC-CD)","methodology_en":"Concentration of sulphate Range: (1,0 – 10000) mg/l Ion chromatography method with conductometric detection (IC-CD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie siarczanów Zakres: (1,0 – 10000) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Concentration of sulphate Range: (1,0 – 10000) mg/l Ion chromatography method with conductometric detection (IC-CD)","reference":"PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Grunty Materiały budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Stężenie siarczanów Zakres: (1,0 – 10000) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Concentration of sulphate Range: (1,0 – 10000) mg/l Ion chromatography method with conductometric detection (IC-CD) PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 10304-1:2009+AC:2012 Zuzle, popioly paleniskowe i pyly z kotlow, popioly lotne z wegla, stale odpady z wapniowych metod odsiarczania gazow odlotowych, piaski ze zloz fluidalnych, mieszaniny popiolow lotnych i odpadow stalych z wapniowych metod odsiarczania gazow odlotowych, mieszanki popiolowo-zuzlowe z mokrego odprowadzania odpadow paleniskowych Grunty Materialy budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Stezenie siarczanow Zakres: (1,0 – 10000) mg/l Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Concentration of sulphate Range: (1,0 – 10000) mg/l Ion chromatography method with conductometric detection (IC-CD) PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 10304-1:2009+AC:2012","categories":["materials","environment","construction"],"row_index":339,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Concentration of sulphate Range: (1,0 – 10000) mg/l Ion chromatography method with conductometric detection (IC-CD) PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 10304-1:2009+AC:2012","search_zh":"炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料；土体；建筑材料：矿物集料 Solid PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 10304-1:2009+AC:2012","test_object_zh":"炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料；土体；建筑材料：矿物集料 Solid"},{"_id":"6a5a55ef9af9f73f38250bf0","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Grunty Materiały budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates","test_object_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates","methodology":"Całkowite substancje rozpuszczone (TDS) Zakres: (10 – 50000) mg/I Metoda wagowa Total dissolved solids (TDS) Range: (10 – 50000) mg/I Gravimetric method","methodology_en":"Total dissolved solids (TDS) Range: (10 – 50000) mg/I Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Całkowite substancje rozpuszczone (TDS) Zakres: (10 – 50000) mg/I Metoda wagowa Total dissolved solids (TDS) Range: (10 – 50000) mg/I Gravimetric method","reference":"PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN 15216:2022-03","norm_bases":["PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN 15216:2022-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Grunty Materiały budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Całkowite substancje rozpuszczone (TDS) Zakres: (10 – 50000) mg/I Metoda wagowa Total dissolved solids (TDS) Range: (10 – 50000) mg/I Gravimetric method PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN 15216:2022-03 Zuzle, popioly paleniskowe i pyly z kotlow, popioly lotne z wegla, stale odpady z wapniowych metod odsiarczania gazow odlotowych, piaski ze zloz fluidalnych, mieszaniny popiolow lotnych i odpadow stalych z wapniowych metod odsiarczania gazow odlotowych, mieszanki popiolowo-zuzlowe z mokrego odprowadzania odpadow paleniskowych Grunty Materialy budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Calkowite substancje rozpuszczone (TDS) Zakres: (10 – 50000) mg/I Metoda wagowa Total dissolved solids (TDS) Range: (10 – 50000) mg/I Gravimetric method PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN 15216:2022-03","categories":["materials","environment","construction"],"row_index":340,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Total dissolved solids (TDS) Range: (10 – 50000) mg/I Gravimetric method PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN 15216:2022-03","search_zh":"炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料；土体；建筑材料：矿物集料 Solid PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN 15216:2022-03","test_object_zh":"炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料；土体；建筑材料：矿物集料 Solid"},{"_id":"6a5a55ef9af9f73f38250bf1","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Grunty Materiały budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates","test_object_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates","methodology":"Stężenie pierwiastków Zakres: Fe (0,0050 – 1000) mg/l Cd (0,0005 – 100) mg/l Mn (0,0050 – 200) mg/l Co, Cr, Ti, V (0,0030 – 100) mg/l As, Cu, Mo, Ni, Pb, Sb, Se, Sn, Zn (0,0050 – 100) mg/l Al (0,050 – 100) mg/l Ba (0,0050 – 2000) mg/l Sr (0,0050 – 1000) mg/l Ca (0,20 – 20000) mg/l Mg (0,12 – 12200) mg/l Na (0,23 – 115000) mg/l K (0,39 – 39100) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Concentration of elements Range: Fe (0,0050 – 1000) mg/l Cd (0,0005 – 100) mg/l Mn (0,0050 – 200) mg/l Co, Cr, Ti, V (0,0030 – 100) mg/l As, Cu, Mo, Ni, Pb, Sb, Se, Sn, Zn (0,0050 – 100) mg/l Al (0,050 – 100) mg/l Ba (0,0050 – 2000) mg/l Sr (0,0050 – 1000) mg/l Ca (0,20 – 20000) mg/l Mg (0,12 – 12200) mg/l Na (0,23 – 115000) mg/l K (0,39 – 39100) mg/l Inductively coupled plasma optical emission spectrometry method (ICP-OES)","methodology_en":"Concentration of elements Range: Fe (0,0050 – 1000) mg/l Cd (0,0005 – 100) mg/l Mn (0,0050 – 200) mg/l Co, Cr, Ti, V (0,0030 – 100) mg/l As, Cu, Mo, Ni, Pb, Sb, Se, Sn, Zn (0,0050 – 100) mg/l Al (0,050 – 100) mg/l Ba (0,0050 – 2000) mg/l Sr (0,0050 – 1000) mg/l Ca (0,20 – 20000) mg/l Mg (0,12 – 12200) mg/l Na (0,23 – 115000) mg/l K (0,39 – 39100) mg/l Inductively coupled plasma optical emission spectrometry method (ICP-OES)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pierwiastków Zakres: Fe (0,0050 – 1000) mg/l Cd (0,0005 – 100) mg/l Mn (0,0050 – 200) mg/l Co, Cr, Ti, V (0,0030 – 100) mg/l As, Cu, Mo, Ni, Pb, Sb, Se, Sn, Zn (0,0050 – 100) mg/l Al (0,050 – 100) mg/l Ba (0,0050 – 2000) mg/l Sr (0,0050 – 1000) mg/l Ca (0,20 – 20000) mg/l Mg (0,12 – 12200) mg/l Na (0,23 – 115000) mg/l K (0,39 – 39100) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Concentration of elements Range: Fe (0,0050 – 1000) mg/l Cd (0,0005 – 100) mg/l Mn (0,0050 – 200) mg/l Co, Cr, Ti, V (0,0030 – 100) mg/l As, Cu, Mo, Ni, Pb, Sb, Se, Sn, Zn (0,0050 – 100) mg/l Al (0,050 – 100) mg/l Ba (0,0050 – 2000) mg/l Sr (0,0050 – 1000) mg/l Ca (0,20 – 20000) mg/l Mg (0,12 – 12200) mg/l Na (0,23 – 115000) mg/l K (0,39 – 39100) mg/l Inductively coupled plasma optical emission spectrometry method (ICP-OES)","reference":"PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 11885:2009","norm_bases":["PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Grunty Materiały budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Stężenie pierwiastków Zakres: Fe (0,0050 – 1000) mg/l Cd (0,0005 – 100) mg/l Mn (0,0050 – 200) mg/l Co, Cr, Ti, V (0,0030 – 100) mg/l As, Cu, Mo, Ni, Pb, Sb, Se, Sn, Zn (0,0050 – 100) mg/l Al (0,050 – 100) mg/l Ba (0,0050 – 2000) mg/l Sr (0,0050 – 1000) mg/l Ca (0,20 – 20000) mg/l Mg (0,12 – 12200) mg/l Na (0,23 – 115000) mg/l K (0,39 – 39100) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Concentration of elements Range: Fe (0,0050 – 1000) mg/l Cd (0,0005 – 100) mg/l Mn (0,0050 – 200) mg/l Co, Cr, Ti, V (0,0030 – 100) mg/l As, Cu, Mo, Ni, Pb, Sb, Se, Sn, Zn (0,0050 – 100) mg/l Al (0,050 – 100) mg/l Ba (0,0050 – 2000) mg/l Sr (0,0050 – 1000) mg/l Ca (0,20 – 20000) mg/l Mg (0,12 – 12200) mg/l Na (0,23 – 115000) mg/l K (0,39 – 39100) mg/l Inductively coupled plasma optical emission spectrometry method (ICP-OES) PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 11885:2009 OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Zuzle, popioly paleniskowe i pyly z kotlow, popioly lotne z wegla, stale odpady z wapniowych metod odsiarczania gazow odlotowych, piaski ze zloz fluidalnych, mieszaniny popiolow lotnych i odpadow stalych z wapniowych metod odsiarczania gazow odlotowych, mieszanki popiolowo-zuzlowe z mokrego odprowadzania odpadow paleniskowych Grunty Materialy budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Stezenie pierwiastkow Zakres: Fe (0,0050 – 1000) mg/l Cd (0,0005 – 100) mg/l Mn (0,0050 – 200) mg/l Co, Cr, Ti, V (0,0030 – 100) mg/l As, Cu, Mo, Ni, Pb, Sb, Se, Sn, Zn (0,0050 – 100) mg/l Al (0,050 – 100) mg/l Ba (0,0050 – 2000) mg/l Sr (0,0050 – 1000) mg/l Ca (0,20 – 20000) mg/l Mg (0,12 – 12200) mg/l Na (0,23 – 115000) mg/l K (0,39 – 39100) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Concentration of elements Range: Fe (0,0050 – 1000) mg/l Cd (0,0005 – 100) mg/l Mn (0,0050 – 200) mg/l Co, Cr, Ti, V (0,0030 – 100) mg/l As, Cu, Mo, Ni, Pb, Sb, Se, Sn, Zn (0,0050 – 100) mg/l Al (0,050 – 100) mg/l Ba (0,0050 – 2000) mg/l Sr (0,0050 – 1000) mg/l Ca (0,20 – 20000) mg/l Mg (0,12 – 12200) mg/l Na (0,23 – 115000) mg/l K (0,39 – 39100) mg/l Inductively coupled plasma optical emission spectrometry method (ICP-OES) PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 11885:2009","categories":["environment","materials","construction"],"row_index":341,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Concentration of elements Range: Fe (0,0050 – 1000) mg/l Cd (0,0005 – 100) mg/l Mn (0,0050 – 200) mg/l Co, Cr, Ti, V (0,0030 – 100) mg/l As, Cu, Mo, Ni, Pb, Sb, Se, Sn, Zn (0,0050 – 100) mg/l Al (0,050 – 100) mg/l Ba (0,0050 – 2000) mg/l Sr (0,0050 – 1000) mg/l Ca (0,20 – 20000) mg/l Mg (0,12 – 12200) mg/l Na (0,23 – 115000) mg/l K (0,39 – 39100) mg/l Inductively coupled plasma optical emission spectrometry method (ICP-OES) PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 11885:2009","search_zh":"废物O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、 PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 11885:2009","test_object_zh":"废物O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、"},{"_id":"6a5a55ef9af9f73f38250bf2","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Grunty Materiały budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates","test_object_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates","methodology":"Stężenie Cr(VI) Zakres: (0,010 – 50) mg/l Metoda spektrofotometryczna Stężenie Cr(III) (z obliczeń) Concentration of Cr(VI) Range: (0,010 – 50) mg/l Spectrofotometric method Concentration of Cr(III) (from calculations)","methodology_en":"Concentration of Cr(VI) Range: (0,010 – 50) mg/l Spectrofotometric method Concentration of Cr(III) (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie Cr(VI) Zakres: (0,010 – 50) mg/l Metoda spektrofotometryczna Stężenie Cr(III) (z obliczeń) Concentration of Cr(VI) Range: (0,010 – 50) mg/l Spectrofotometric method Concentration of Cr(III) (from calculations)","reference":"PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 18412:2007 PN-77/C-04604.08 SO-4/ZLGIG/PB.07.93 ed. 1 z dn. 01.08.2025 PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 18412:2007 PN-77/C-04604.08 SO-4/ZLGIG/PB.07.93 ed. 1st of 01/08/2025","norm_bases":["PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 18412:2007 PN-77/C-04604.08 SO-4/ZLGIG/PB.07.93 ed. 1 z dn. 01.08.2025 PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 18412:2007 PN-77/C-04604.08 SO-4/ZLGIG/PB.07.93 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Grunty Materiały budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Stężenie Cr(VI) Zakres: (0,010 – 50) mg/l Metoda spektrofotometryczna Stężenie Cr(III) (z obliczeń) Concentration of Cr(VI) Range: (0,010 – 50) mg/l Spectrofotometric method Concentration of Cr(III) (from calculations) PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 18412:2007 PN-77/C-04604.08 SO-4/ZLGIG/PB.07.93 ed. 1 z dn. 01.08.2025 PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 18412:2007 PN-77/C-04604.08 SO-4/ZLGIG/PB.07.93 ed. 1st of 01/08/2025 OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Zuzle, popioly paleniskowe i pyly z kotlow, popioly lotne z wegla, stale odpady z wapniowych metod odsiarczania gazow odlotowych, piaski ze zloz fluidalnych, mieszaniny popiolow lotnych i odpadow stalych z wapniowych metod odsiarczania gazow odlotowych, mieszanki popiolowo-zuzlowe z mokrego odprowadzania odpadow paleniskowych Grunty Materialy budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Stezenie Cr(VI) Zakres: (0,010 – 50) mg/l Metoda spektrofotometryczna Stezenie Cr(III) (z obliczen) Concentration of Cr(VI) Range: (0,010 – 50) mg/l Spectrofotometric method Concentration of Cr(III) (from calculations) PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 18412:2007 PN-77/C-04604.08 SO-4/ZLGIG/PB.07.93 ed. 1 z dn. 01.08.2025 PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 18412:2007 PN-77/C-04604.08 SO-4/ZLGIG/PB.07.93 ed. 1st of 01/08/2025","categories":["materials","environment","construction"],"row_index":342,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Concentration of Cr(VI) Range: (0,010 – 50) mg/l Spectrofotometric method Concentration of Cr(III) (from calculations) PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 18412:2007 PN-77/C-04604.08 SO-4/ZLGIG/PB.07.93 ed. 1 z dn. 01.08.2025 PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 18412:2007 PN-77/C-04604.08 SO-4/ZLGIG/PB.07.93 ed. 1st of 01/08/2025","search_zh":"废物O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、 PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 18412:2007 PN-77/C-04604.08 SO-4/ZLGIG/PB.07.93 ed. 1 z dn. 01.08.2025 PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 18412:2007 PN-77/C-04604.08 SO-4/ZLGIG/PB.07.93 ed. 1st of 01/08/2025","test_object_zh":"废物O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、"},{"_id":"6a5a55ef9af9f73f38250bf3","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Grunty Materiały budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates","test_object_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates","methodology":"Indeks nadmanganianowy Zakres: (0,50 – 100) mg/l O 2 Metoda miareczkowa Permanganate index Range: (0,50 – 100) mg/l O 2 Titrimetric method","methodology_en":"Permanganate index Range: (0,50 – 100) mg/l O 2 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy Zakres: (0,50 – 100) mg/l O 2 Metoda miareczkowa Permanganate index Range: (0,50 – 100) mg/l O 2 Titrimetric method","reference":"PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 8467:2001","norm_bases":["PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Grunty Materiały budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Indeks nadmanganianowy Zakres: (0,50 – 100) mg/l O 2 Metoda miareczkowa Permanganate index Range: (0,50 – 100) mg/l O 2 Titrimetric method PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 8467:2001 OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Zuzle, popioly paleniskowe i pyly z kotlow, popioly lotne z wegla, stale odpady z wapniowych metod odsiarczania gazow odlotowych, piaski ze zloz fluidalnych, mieszaniny popiolow lotnych i odpadow stalych z wapniowych metod odsiarczania gazow odlotowych, mieszanki popiolowo-zuzlowe z mokrego odprowadzania odpadow paleniskowych Grunty Materialy budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Indeks nadmanganianowy Zakres: (0,50 – 100) mg/l O 2 Metoda miareczkowa Permanganate index Range: (0,50 – 100) mg/l O 2 Titrimetric method PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 8467:2001","categories":["materials","environment","construction"],"row_index":343,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Permanganate index Range: (0,50 – 100) mg/l O 2 Titrimetric method PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 8467:2001","search_zh":"废物O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、 PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 8467:2001","test_object_zh":"废物O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、"},{"_id":"6a5a55ef9af9f73f38250bf4","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Grunty Materiały budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates","test_object_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates","methodology":"Stężenie węgla organicznego Zakres: (0,50 – 2500) mg/l C Metoda wysokotemperaturowego spalania z detekcją IR Concentration of organic carbon Range: (0,50 – 2500) mg/l C High temp. combustion method with IR detection","methodology_en":"Concentration of organic carbon Range: (0,50 – 2500) mg/l C High temp. combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie węgla organicznego Zakres: (0,50 – 2500) mg/l C Metoda wysokotemperaturowego spalania z detekcją IR Concentration of organic carbon Range: (0,50 – 2500) mg/l C High temp. combustion method with IR detection","reference":"PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN 1484:1999","norm_bases":["PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN 1484:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Grunty Materiały budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Stężenie węgla organicznego Zakres: (0,50 – 2500) mg/l C Metoda wysokotemperaturowego spalania z detekcją IR Concentration of organic carbon Range: (0,50 – 2500) mg/l C High temp. combustion method with IR detection PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN 1484:1999 OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Zuzle, popioly paleniskowe i pyly z kotlow, popioly lotne z wegla, stale odpady z wapniowych metod odsiarczania gazow odlotowych, piaski ze zloz fluidalnych, mieszaniny popiolow lotnych i odpadow stalych z wapniowych metod odsiarczania gazow odlotowych, mieszanki popiolowo-zuzlowe z mokrego odprowadzania odpadow paleniskowych Grunty Materialy budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Stezenie wegla organicznego Zakres: (0,50 – 2500) mg/l C Metoda wysokotemperaturowego spalania z detekcja IR Concentration of organic carbon Range: (0,50 – 2500) mg/l C High temp. combustion method with IR detection PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN 1484:1999","categories":["materials","environment","construction"],"row_index":344,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Concentration of organic carbon Range: (0,50 – 2500) mg/l C High temp. combustion method with IR detection PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN 1484:1999","search_zh":"废物O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、 PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN 1484:1999","test_object_zh":"废物O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、"},{"_id":"6a5a55ef9af9f73f38250bf5","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Grunty Materiały budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates","test_object_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates","methodology":"Stężenie siarczków Zakres: (0,050 – 500) mg/l Metoda spektrofotometryczna Metoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną Stężenie siarkowodoru niezdysocjowanego (z obliczeń)","methodology_en":"Sulphide concentration Range: (0,050 – 500) mg/l Spectrophotometric method Flow injection analysis method (FIA) with spectrophotometric detection Concentration of undissociated hydrogen sulphide (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie siarczków Zakres: (0,050 – 500) mg/l Metoda spektrofotometryczna Metoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną Stężenie siarkowodoru niezdysocjowanego (z obliczeń)","reference":"PN-EN 12457-2:2006 PN-EN 12457-4:2006 SO-4/ZLGIG/PB.07.39 ed. 1 z dn. 01.08.2025 na podstawie testu kuwetowego MERCK SPECTROQUANT 14779 SO-4/ZLGIG/PB.07.51 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.07.97 ed.1 z dn. 01.08.2025 PN-74/C-04566.04","norm_bases":["PN-EN 12457-2:2006 PN-EN 12457-4:2006 SO-4/ZLGIG/PB.07.39 ed. 1 z dn. 01.08.2025 na podstawie testu kuwetowego MERCK SPECTROQUANT 14779 SO-4/ZLGIG/PB.07.51 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.07.97 ed.1 z dn. 01.08.2025 PN-74/C-04566.04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Grunty Materiały budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Stężenie siarczków Zakres: (0,050 – 500) mg/l Metoda spektrofotometryczna Metoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną Stężenie siarkowodoru niezdysocjowanego (z obliczeń) PN-EN 12457-2:2006 PN-EN 12457-4:2006 SO-4/ZLGIG/PB.07.39 ed. 1 z dn. 01.08.2025 na podstawie testu kuwetowego MERCK SPECTROQUANT 14779 SO-4/ZLGIG/PB.07.51 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.07.97 ed.1 z dn. 01.08.2025 PN-74/C-04566.04 OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Zuzle, popioly paleniskowe i pyly z kotlow, popioly lotne z wegla, stale odpady z wapniowych metod odsiarczania gazow odlotowych, piaski ze zloz fluidalnych, mieszaniny popiolow lotnych i odpadow stalych z wapniowych metod odsiarczania gazow odlotowych, mieszanki popiolowo-zuzlowe z mokrego odprowadzania odpadow paleniskowych Grunty Materialy budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Stezenie siarczkow Zakres: (0,050 – 500) mg/l Metoda spektrofotometryczna Metoda wstrzykowej analizy przeplywowej (FIA) z detekcja spektrofotometryczna Stezenie siarkowodoru niezdysocjowanego (z obliczen) PN-EN 12457-2:2006 PN-EN 12457-4:2006 SO-4/ZLGIG/PB.07.39 ed. 1 z dn. 01.08.2025 na podstawie testu kuwetowego MERCK SPECTROQUANT 14779 SO-4/ZLGIG/PB.07.51 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.07.97 ed.1 z dn. 01.08.2025 PN-74/C-04566.04","categories":["materials","environment","construction"],"row_index":345,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Sulphide concentration Range: (0,050 – 500) mg/l Spectrophotometric method Flow injection analysis method (FIA) with spectrophotometric detection Concentration of undissociated hydrogen sulphide (calculated) PN-EN 12457-2:2006 PN-EN 12457-4:2006 SO-4/ZLGIG/PB.07.39 ed. 1 z dn. 01.08.2025 na podstawie testu kuwetowego MERCK SPECTROQUANT 14779 SO-4/ZLGIG/PB.07.51 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.07.97 ed.1 z dn. 01.08.2025 PN-74/C-04566.04","search_zh":"废物O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、 PN-EN 12457-2:2006 PN-EN 12457-4:2006 SO-4/ZLGIG/PB.07.39 ed. 1 z dn. 01.08.2025 na podstawie testu kuwetowego MERCK SPECTROQUANT 14779 SO-4/ZLGIG/PB.07.51 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.07.97 ed.1 z dn. 01.08.2025 PN-74/C-04566.04","test_object_zh":"废物O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、"},{"_id":"6a5a55ef9af9f73f38250bf6","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Grunty Materiały budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates","test_object_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates","methodology":"Concentration of sulfides Range: (0,050 – 500) mg/l Spectrophotometric method Flow injection analysis method (FIA) with spectrophotometric detection Unionized hydrogen sulfide (from calculations)","methodology_en":"Concentration of sulfides Range: (0,050 – 500) mg/l Spectrophotometric method Flow injection analysis method (FIA) with spectrophotometric detection Unionized hydrogen sulfide (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Concentration of sulfides Range: (0,050 – 500) mg/l Spectrophotometric method Flow injection analysis method (FIA) with spectrophotometric detection Unionized hydrogen sulfide (from calculations)","reference":"PN-EN 12457-2:2006 PN-EN 12457-4:2006 SO-4/ZLGIG/PB.07.39 ed. 1st of 01/08/2025 based on cuvette test MERCK SPECTROQUANT 14779 SO-4/ZLGIG/PB.07.51 ed. 1st of 01/08/2025 SO-4/ZLGIG/PB.07.97 ed. 1st of 01/08/2025 PN-74/C-04566.04","norm_bases":["PN-EN 12457-2:2006 PN-EN 12457-4:2006 SO-4/ZLGIG/PB.07.39 ed. 1st of 01/08/2025 based on cuvette test MERCK SPECTROQUANT 14779 SO-4/ZLGIG/PB.07.51 ed. 1st of 01/08/2025 SO-4/ZLGIG/PB.07.97 ed. 1st of 01/08/2025 PN-74/C-04566.04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Grunty Materiały budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Concentration of sulfides Range: (0,050 – 500) mg/l Spectrophotometric method Flow injection analysis method (FIA) with spectrophotometric detection Unionized hydrogen sulfide (from calculations) PN-EN 12457-2:2006 PN-EN 12457-4:2006 SO-4/ZLGIG/PB.07.39 ed. 1st of 01/08/2025 based on cuvette test MERCK SPECTROQUANT 14779 SO-4/ZLGIG/PB.07.51 ed. 1st of 01/08/2025 SO-4/ZLGIG/PB.07.97 ed. 1st of 01/08/2025 PN-74/C-04566.04 OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Zuzle, popioly paleniskowe i pyly z kotlow, popioly lotne z wegla, stale odpady z wapniowych metod odsiarczania gazow odlotowych, piaski ze zloz fluidalnych, mieszaniny popiolow lotnych i odpadow stalych z wapniowych metod odsiarczania gazow odlotowych, mieszanki popiolowo-zuzlowe z mokrego odprowadzania odpadow paleniskowych Grunty Materialy budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Concentration of sulfides Range: (0,050 – 500) mg/l Spectrophotometric method Flow injection analysis method (FIA) with spectrophotometric detection Unionized hydrogen sulfide (from calculations) PN-EN 12457-2:2006 PN-EN 12457-4:2006 SO-4/ZLGIG/PB.07.39 ed. 1st of 01/08/2025 based on cuvette test MERCK SPECTROQUANT 14779 SO-4/ZLGIG/PB.07.51 ed. 1st of 01/08/2025 SO-4/ZLGIG/PB.07.97 ed. 1st of 01/08/2025 PN-74/C-04566.04","categories":["materials","environment","construction"],"row_index":346,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Concentration of sulfides Range: (0,050 – 500) mg/l Spectrophotometric method Flow injection analysis method (FIA) with spectrophotometric detection Unionized hydrogen sulfide (from calculations) PN-EN 12457-2:2006 PN-EN 12457-4:2006 SO-4/ZLGIG/PB.07.39 ed. 1st of 01/08/2025 based on cuvette test MERCK SPECTROQUANT 14779 SO-4/ZLGIG/PB.07.51 ed. 1st of 01/08/2025 SO-4/ZLGIG/PB.07.97 ed. 1st of 01/08/2025 PN-74/C-04566.04","search_zh":"废物O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料；土体；建筑材料：矿物集料 Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates PN-EN 12457-2:2006 PN-EN 12457-4:2006 SO-4/ZLGIG/PB.07.39 ed. 1st of 01/08/2025 based on cuvette test MERCK SPECTROQUANT 14779 SO-4/ZLGIG/PB.07.51 ed. 1st of 01/08/2025 SO-4/ZLGIG/PB.07.97 ed. 1st of 01/08/2025 PN-74/C-04566.04","test_object_zh":"废物O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料；土体；建筑材料：矿物集料 Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates"},{"_id":"6a5a55ef9af9f73f38250bf7","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Grunty Materiały budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates","test_object_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates","methodology":"Stężenie cyjanków wolnych, ogólnych Zakres: (0,0050 – 1000) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną Stężenie cyjanków związanych (z obliczeń) Concentration of free cyanide and total cyanide Range: (0,0050 – 1000) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection Concentration of cyanide – bound (from calculations)","methodology_en":"Concentration of free cyanide and total cyanide Range: (0,0050 – 1000) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection Concentration of cyanide – bound (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie cyjanków wolnych, ogólnych Zakres: (0,0050 – 1000) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną Stężenie cyjanków związanych (z obliczeń) Concentration of free cyanide and total cyanide Range: (0,0050 – 1000) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection Concentration of cyanide – bound (from calculations)","reference":"PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 14403-2:2012 SO-4/ZLGIG/PB.07.90 ed. 1 z dn. 01.08.2025 PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 14403-2:2012 SO-4/ZLGIG/PB.07.90 ed. 1st of 01/08/2025","norm_bases":["PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 14403-2:2012 SO-4/ZLGIG/PB.07.90 ed. 1 z dn. 01.08.2025 PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 14403-2:2012 SO-4/ZLGIG/PB.07.90 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Grunty Materiały budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Stężenie cyjanków wolnych, ogólnych Zakres: (0,0050 – 1000) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną Stężenie cyjanków związanych (z obliczeń) Concentration of free cyanide and total cyanide Range: (0,0050 – 1000) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection Concentration of cyanide – bound (from calculations) PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 14403-2:2012 SO-4/ZLGIG/PB.07.90 ed. 1 z dn. 01.08.2025 PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 14403-2:2012 SO-4/ZLGIG/PB.07.90 ed. 1st of 01/08/2025 OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Zuzle, popioly paleniskowe i pyly z kotlow, popioly lotne z wegla, stale odpady z wapniowych metod odsiarczania gazow odlotowych, piaski ze zloz fluidalnych, mieszaniny popiolow lotnych i odpadow stalych z wapniowych metod odsiarczania gazow odlotowych, mieszanki popiolowo-zuzlowe z mokrego odprowadzania odpadow paleniskowych Grunty Materialy budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Stezenie cyjankow wolnych, ogolnych Zakres: (0,0050 – 1000) mg/l Metoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna Stezenie cyjankow zwiazanych (z obliczen) Concentration of free cyanide and total cyanide Range: (0,0050 – 1000) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection Concentration of cyanide – bound (from calculations) PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 14403-2:2012 SO-4/ZLGIG/PB.07.90 ed. 1 z dn. 01.08.2025 PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 14403-2:2012 SO-4/ZLGIG/PB.07.90 ed. 1st of 01/08/2025","categories":["materials","environment","construction"],"row_index":347,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Concentration of free cyanide and total cyanide Range: (0,0050 – 1000) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection Concentration of cyanide – bound (from calculations) PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 14403-2:2012 SO-4/ZLGIG/PB.07.90 ed. 1 z dn. 01.08.2025 PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 14403-2:2012 SO-4/ZLGIG/PB.07.90 ed. 1st of 01/08/2025","search_zh":"废物O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料；土体；建筑材料：矿物集料 Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 14403-2:2012 SO-4/ZLGIG/PB.07.90 ed. 1 z dn. 01.08.2025 PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 14403-2:2012 SO-4/ZLGIG/PB.07.90 ed. 1st of 01/08/2025","test_object_zh":"废物O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料；土体；建筑材料：矿物集料 Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates"},{"_id":"6a5a55ef9af9f73f38250bf8","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Grunty Materiały budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates","test_object_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates","methodology":"Indeks fenolowy Zakres: (0,0050 – 1000) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną Phenol index Range: (0,0050 – 1000) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection","methodology_en":"Phenol index Range: (0,0050 – 1000) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indeks fenolowy Zakres: (0,0050 – 1000) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną Phenol index Range: (0,0050 – 1000) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection","reference":"PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 14402:2004 pkt 4 PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 14402:2004 pt 4","norm_bases":["PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 14402:2004 pkt 4 PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 14402:2004 pt 4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Grunty Materiały budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Indeks fenolowy Zakres: (0,0050 – 1000) mg/l Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną Phenol index Range: (0,0050 – 1000) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 14402:2004 pkt 4 PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 14402:2004 pt 4 OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Zuzle, popioly paleniskowe i pyly z kotlow, popioly lotne z wegla, stale odpady z wapniowych metod odsiarczania gazow odlotowych, piaski ze zloz fluidalnych, mieszaniny popiolow lotnych i odpadow stalych z wapniowych metod odsiarczania gazow odlotowych, mieszanki popiolowo-zuzlowe z mokrego odprowadzania odpadow paleniskowych Grunty Materialy budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Indeks fenolowy Zakres: (0,0050 – 1000) mg/l Metoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna Phenol index Range: (0,0050 – 1000) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 14402:2004 pkt 4 PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 14402:2004 pt 4","categories":["materials","environment","construction"],"row_index":348,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Phenol index Range: (0,0050 – 1000) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 14402:2004 pkt 4 PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 14402:2004 pt 4","search_zh":"废物O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料；土体；建筑材料：矿物集料 Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 14402:2004 pkt 4 PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 14402:2004 pt 4","test_object_zh":"废物O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料；土体；建筑材料：矿物集料 Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates"},{"_id":"6a5a55ef9af9f73f38250bf9","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Grunty Materiały budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates","test_object_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates","methodology":"Stężenie jonu amonowego Zakres: (0,020 – 1000) mg/l Stężenie azotu amonowego (0,016 – 777) mg/l Metoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną Ammonium ion concentration Range: (0,020 – 1000) mg/l Ammonium nitrogen concentration Range: (0,016 – 777) mg/l Flow injection analysis method (FIA) with spectrophotometric detection","methodology_en":"Ammonium ion concentration Range: (0,020 – 1000) mg/l Ammonium nitrogen concentration Range: (0,016 – 777) mg/l Flow injection analysis method (FIA) with spectrophotometric detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego Zakres: (0,020 – 1000) mg/l Stężenie azotu amonowego (0,016 – 777) mg/l Metoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną Ammonium ion concentration Range: (0,020 – 1000) mg/l Ammonium nitrogen concentration Range: (0,016 – 777) mg/l Flow injection analysis method (FIA) with spectrophotometric detection","reference":"PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 11732:2007","norm_bases":["PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 11732:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Grunty Materiały budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Stężenie jonu amonowego Zakres: (0,020 – 1000) mg/l Stężenie azotu amonowego (0,016 – 777) mg/l Metoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną Ammonium ion concentration Range: (0,020 – 1000) mg/l Ammonium nitrogen concentration Range: (0,016 – 777) mg/l Flow injection analysis method (FIA) with spectrophotometric detection PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 11732:2007 OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Zuzle, popioly paleniskowe i pyly z kotlow, popioly lotne z wegla, stale odpady z wapniowych metod odsiarczania gazow odlotowych, piaski ze zloz fluidalnych, mieszaniny popiolow lotnych i odpadow stalych z wapniowych metod odsiarczania gazow odlotowych, mieszanki popiolowo-zuzlowe z mokrego odprowadzania odpadow paleniskowych Grunty Materialy budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Stezenie jonu amonowego Zakres: (0,020 – 1000) mg/l Stezenie azotu amonowego (0,016 – 777) mg/l Metoda wstrzykowej analizy przeplywowej (FIA) z detekcja spektrofotometryczna Ammonium ion concentration Range: (0,020 – 1000) mg/l Ammonium nitrogen concentration Range: (0,016 – 777) mg/l Flow injection analysis method (FIA) with spectrophotometric detection PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 11732:2007","categories":["materials","environment","construction"],"row_index":349,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Ammonium ion concentration Range: (0,020 – 1000) mg/l Ammonium nitrogen concentration Range: (0,016 – 777) mg/l Flow injection analysis method (FIA) with spectrophotometric detection PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 11732:2007","search_zh":"废物O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料；土体；建筑材料：矿物集料 Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 11732:2007","test_object_zh":"废物O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料；土体；建筑材料：矿物集料 Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates"},{"_id":"6a5a55ef9af9f73f38250bfa","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Grunty Materiały budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates","test_object_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates","methodology":"Stężenie fluorków Zakres: (0,10 – 500) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Fluoride concentration Range: (0,10 – 500) mg/l Ion chromatography method with conductometric detection (IC-CD)","methodology_en":"Fluoride concentration Range: (0,10 – 500) mg/l Ion chromatography method with conductometric detection (IC-CD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fluorków Zakres: (0,10 – 500) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Fluoride concentration Range: (0,10 – 500) mg/l Ion chromatography method with conductometric detection (IC-CD)","reference":"PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Grunty Materiały budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Stężenie fluorków Zakres: (0,10 – 500) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Fluoride concentration Range: (0,10 – 500) mg/l Ion chromatography method with conductometric detection (IC-CD) PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 10304-1:2009+AC:2012 OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Zuzle, popioly paleniskowe i pyly z kotlow, popioly lotne z wegla, stale odpady z wapniowych metod odsiarczania gazow odlotowych, piaski ze zloz fluidalnych, mieszaniny popiolow lotnych i odpadow stalych z wapniowych metod odsiarczania gazow odlotowych, mieszanki popiolowo-zuzlowe z mokrego odprowadzania odpadow paleniskowych Grunty Materialy budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Stezenie fluorkow Zakres: (0,10 – 500) mg/l Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Fluoride concentration Range: (0,10 – 500) mg/l Ion chromatography method with conductometric detection (IC-CD) PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 10304-1:2009+AC:2012","categories":["materials","environment","construction"],"row_index":350,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Fluoride concentration Range: (0,10 – 500) mg/l Ion chromatography method with conductometric detection (IC-CD) PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 10304-1:2009+AC:2012","search_zh":"废物O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料；土体；建筑材料：矿物集料 Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 10304-1:2009+AC:2012","test_object_zh":"废物O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料；土体；建筑材料：矿物集料 Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates"},{"_id":"6a5a55ef9af9f73f38250bfb","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Grunty Materiały budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates","test_object_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates","methodology":"Stężenie rtęci Zakres: (0,00050 – 0,10) mg/l (0,50 – 100) µg/l Metoda atomowej spektrometrii fluorescencyjnej (AFS) Concentration of mercury Range: (0,00050 – 0,10) mg/l (0,50 – 100) µg/l Atomic fluorescence spectrometry method (AFS)","methodology_en":"Concentration of mercury Range: (0,00050 – 0,10) mg/l (0,50 – 100) µg/l Atomic fluorescence spectrometry method (AFS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie rtęci Zakres: (0,00050 – 0,10) mg/l (0,50 – 100) µg/l Metoda atomowej spektrometrii fluorescencyjnej (AFS) Concentration of mercury Range: (0,00050 – 0,10) mg/l (0,50 – 100) µg/l Atomic fluorescence spectrometry method (AFS)","reference":"PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 17852:2009","norm_bases":["PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 17852:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Grunty Materiały budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Stężenie rtęci Zakres: (0,00050 – 0,10) mg/l (0,50 – 100) µg/l Metoda atomowej spektrometrii fluorescencyjnej (AFS) Concentration of mercury Range: (0,00050 – 0,10) mg/l (0,50 – 100) µg/l Atomic fluorescence spectrometry method (AFS) PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 17852:2009 OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Zuzle, popioly paleniskowe i pyly z kotlow, popioly lotne z wegla, stale odpady z wapniowych metod odsiarczania gazow odlotowych, piaski ze zloz fluidalnych, mieszaniny popiolow lotnych i odpadow stalych z wapniowych metod odsiarczania gazow odlotowych, mieszanki popiolowo-zuzlowe z mokrego odprowadzania odpadow paleniskowych Grunty Materialy budowlane: kruszywa mineralne Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Stezenie rteci Zakres: (0,00050 – 0,10) mg/l (0,50 – 100) µg/l Metoda atomowej spektrometrii fluorescencyjnej (AFS) Concentration of mercury Range: (0,00050 – 0,10) mg/l (0,50 – 100) µg/l Atomic fluorescence spectrometry method (AFS) PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 17852:2009","categories":["materials","environment","construction"],"row_index":351,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates Concentration of mercury Range: (0,00050 – 0,10) mg/l (0,50 – 100) µg/l Atomic fluorescence spectrometry method (AFS) PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 17852:2009","search_zh":"废物O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料；土体；建筑材料：矿物集料 Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates PN-EN 12457-2:2006 PN-EN 12457-4:2006 PN-EN ISO 17852:2009","test_object_zh":"废物O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料；土体；建筑材料：矿物集料 Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ground Building materials: mineral aggregates"},{"_id":"6a5a55ef9af9f73f38250bfc","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Materiały budowlane: kruszywa mineralne Building materials: mineral aggregates","test_object_en":"Building materials: mineral aggregates","methodology":"Zawartość wilgoci analitycznej Zakres: (0,10 – 10,0) %m/m Metoda wagowa Analytical moisture content Range: (0,10 – 10,0) %m/m Gravimetric method","methodology_en":"Analytical moisture content Range: (0,10 – 10,0) %m/m Gravimetric method Analytical moisture content Range: (0,10 – 10,0) %m/m Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci analitycznej Zakres: (0,10 – 10,0) %m/m Metoda wagowa Analytical moisture content Range: (0,10 – 10,0) %m/m Gravimetric method","reference":"SO-4/ZLGIG/PB.02 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.02 ed. 1st of 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.02 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.02 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały budowlane: kruszywa mineralne Building materials: mineral aggregates Zawartość wilgoci analitycznej Zakres: (0,10 – 10,0) %m/m Metoda wagowa Analytical moisture content Range: (0,10 – 10,0) %m/m Gravimetric method SO-4/ZLGIG/PB.02 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.02 ed. 1st of 01/08/2025 Materialy budowlane: kruszywa mineralne Building materials: mineral aggregates Zawartosc wilgoci analitycznej Zakres: (0,10 – 10,0) %m/m Metoda wagowa Analytical moisture content Range: (0,10 – 10,0) %m/m Gravimetric method SO-4/ZLGIG/PB.02 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.02 ed. 1st of 01/08/2025","categories":["materials","construction"],"row_index":352,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building materials: mineral aggregates Analytical moisture content Range: (0,10 – 10,0) %m/m Gravimetric method Analytical moisture content Range: (0,10 – 10,0) %m/m Gravimetric method SO-4/ZLGIG/PB.02 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.02 ed. 1st of 01/08/2025","search_zh":"建筑材料：矿物集料 Building materials: mineral aggregates SO-4/ZLGIG/PB.02 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.02 ed. 1st of 01/08/2025","test_object_zh":"建筑材料：矿物集料 Building materials: mineral aggregates"},{"_id":"6a5a55ef9af9f73f38250bfd","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Materiały budowlane: kruszywa mineralne Building materials: mineral aggregates","test_object_en":"Building materials: mineral aggregates","methodology":"Zawartość popiołu Zakres: (35,00 – 99,00) %m/m Metoda wagowa Zawartość strat prażenia (z obliczeń) Ash content Range: (35,00 – 99,00) %m/m Gravimetric method Loss on ignition (from calculations)","methodology_en":"Ash content Range: (35,00 – 99,00) %m/m Gravimetric method Loss on ignition (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość popiołu Zakres: (35,00 – 99,00) %m/m Metoda wagowa Zawartość strat prażenia (z obliczeń) Ash content Range: (35,00 – 99,00) %m/m Gravimetric method Loss on ignition (from calculations)","reference":"SO-4/ZLGIG/PB.03 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.03 ed. 1st of 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.03 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.03 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały budowlane: kruszywa mineralne Building materials: mineral aggregates Zawartość popiołu Zakres: (35,00 – 99,00) %m/m Metoda wagowa Zawartość strat prażenia (z obliczeń) Ash content Range: (35,00 – 99,00) %m/m Gravimetric method Loss on ignition (from calculations) SO-4/ZLGIG/PB.03 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.03 ed. 1st of 01/08/2025 Materialy budowlane: kruszywa mineralne Building materials: mineral aggregates Zawartosc popiolu Zakres: (35,00 – 99,00) %m/m Metoda wagowa Zawartosc strat prazenia (z obliczen) Ash content Range: (35,00 – 99,00) %m/m Gravimetric method Loss on ignition (from calculations) SO-4/ZLGIG/PB.03 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.03 ed. 1st of 01/08/2025","categories":["materials","construction"],"row_index":353,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building materials: mineral aggregates Ash content Range: (35,00 – 99,00) %m/m Gravimetric method Loss on ignition (from calculations) SO-4/ZLGIG/PB.03 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.03 ed. 1st of 01/08/2025","search_zh":"建筑材料：矿物集料 Building materials: mineral aggregates SO-4/ZLGIG/PB.03 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.03 ed. 1st of 01/08/2025","test_object_zh":"建筑材料：矿物集料 Building materials: mineral aggregates"},{"_id":"6a5a55ef9af9f73f38250bfe","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Materiały budowlane: kruszywa mineralne Building materials: mineral aggregates","test_object_en":"Building materials: mineral aggregates","methodology":"Zawartość pierwiastków Zakres: As (1,0 – 100000) mg/kg Ba (1,0 – 100000) mg/kg Cd (1,0 – 100000) mg/kg Co (1,0 – 100000) mg/kg Cr (1,0 – 100000) mg/kg Cu (1,0 – 100000) mg/kg Mn (1,0 – 100000) mg/kg Mo (1,0 – 100000) mg/kg Ni (1,0 – 100000) mg/kg Pb (1,0 – 100000) mg/kg Sb (1,0 – 100000) mg/kg Se (2,0 – 100000) mg/kg Sn (1,0 – 100000) mg/kg Zn (1,0 – 100000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Elements content Range: As (1,0 – 100000) mg/kg Ba (1,0 – 100000) mg/kg Cd (1,0 – 100000) mg/kg Co (1,0 – 100000) mg/kg Cr (1,0 – 100000) mg/kg Cu (1,0 – 100000) mg/kg Mn (1,0 – 100000) mg/kg Mo (1,0 – 100000) mg/kg Ni (1,0 – 100000) mg/kg Pb (1,0 – 100000) mg/kg Sb (1,0 – 100000) mg/kg Se (2,0 – 100000) mg/kg Sn (1,0 – 100000) mg/kg Zn (1,0 – 100000) mg/kg Inductively coupled plasma optical emission spectrometry method method (ICP-OES)","methodology_en":"Elements content Range: As (1,0 – 100000) mg/kg Ba (1,0 – 100000) mg/kg Cd (1,0 – 100000) mg/kg Co (1,0 – 100000) mg/kg Cr (1,0 – 100000) mg/kg Cu (1,0 – 100000) mg/kg Mn (1,0 – 100000) mg/kg Mo (1,0 – 100000) mg/kg Ni (1,0 – 100000) mg/kg Pb (1,0 – 100000) mg/kg Sb (1,0 – 100000) mg/kg Se (2,0 – 100000) mg/kg Sn (1,0 – 100000) mg/kg Zn (1,0 – 100000) mg/kg Inductively coupled plasma optical emission spectrometry method method (ICP-OES)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość pierwiastków Zakres: As (1,0 – 100000) mg/kg Ba (1,0 – 100000) mg/kg Cd (1,0 – 100000) mg/kg Co (1,0 – 100000) mg/kg Cr (1,0 – 100000) mg/kg Cu (1,0 – 100000) mg/kg Mn (1,0 – 100000) mg/kg Mo (1,0 – 100000) mg/kg Ni (1,0 – 100000) mg/kg Pb (1,0 – 100000) mg/kg Sb (1,0 – 100000) mg/kg Se (2,0 – 100000) mg/kg Sn (1,0 – 100000) mg/kg Zn (1,0 – 100000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Elements content Range: As (1,0 – 100000) mg/kg Ba (1,0 – 100000) mg/kg Cd (1,0 – 100000) mg/kg Co (1,0 – 100000) mg/kg Cr (1,0 – 100000) mg/kg Cu (1,0 – 100000) mg/kg Mn (1,0 – 100000) mg/kg Mo (1,0 – 100000) mg/kg Ni (1,0 – 100000) mg/kg Pb (1,0 – 100000) mg/kg Sb (1,0 – 100000) mg/kg Se (2,0 – 100000) mg/kg Sn (1,0 – 100000) mg/kg Zn (1,0 – 100000) mg/kg Inductively coupled plasma optical emission spectrometry method method (ICP-OES)","reference":"SO-4/ZLGIG/PB.11 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.11 ed. 1st of 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.11 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.11 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały budowlane: kruszywa mineralne Building materials: mineral aggregates Zawartość pierwiastków Zakres: As (1,0 – 100000) mg/kg Ba (1,0 – 100000) mg/kg Cd (1,0 – 100000) mg/kg Co (1,0 – 100000) mg/kg Cr (1,0 – 100000) mg/kg Cu (1,0 – 100000) mg/kg Mn (1,0 – 100000) mg/kg Mo (1,0 – 100000) mg/kg Ni (1,0 – 100000) mg/kg Pb (1,0 – 100000) mg/kg Sb (1,0 – 100000) mg/kg Se (2,0 – 100000) mg/kg Sn (1,0 – 100000) mg/kg Zn (1,0 – 100000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Elements content Range: As (1,0 – 100000) mg/kg Ba (1,0 – 100000) mg/kg Cd (1,0 – 100000) mg/kg Co (1,0 – 100000) mg/kg Cr (1,0 – 100000) mg/kg Cu (1,0 – 100000) mg/kg Mn (1,0 – 100000) mg/kg Mo (1,0 – 100000) mg/kg Ni (1,0 – 100000) mg/kg Pb (1,0 – 100000) mg/kg Sb (1,0 – 100000) mg/kg Se (2,0 – 100000) mg/kg Sn (1,0 – 100000) mg/kg Zn (1,0 – 100000) mg/kg Inductively coupled plasma optical emission spectrometry method method (ICP-OES) SO-4/ZLGIG/PB.11 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.11 ed. 1st of 01/08/2025 Materialy budowlane: kruszywa mineralne Building materials: mineral aggregates Zawartosc pierwiastkow Zakres: As (1,0 – 100000) mg/kg Ba (1,0 – 100000) mg/kg Cd (1,0 – 100000) mg/kg Co (1,0 – 100000) mg/kg Cr (1,0 – 100000) mg/kg Cu (1,0 – 100000) mg/kg Mn (1,0 – 100000) mg/kg Mo (1,0 – 100000) mg/kg Ni (1,0 – 100000) mg/kg Pb (1,0 – 100000) mg/kg Sb (1,0 – 100000) mg/kg Se (2,0 – 100000) mg/kg Sn (1,0 – 100000) mg/kg Zn (1,0 – 100000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Elements content Range: As (1,0 – 100000) mg/kg Ba (1,0 – 100000) mg/kg Cd (1,0 – 100000) mg/kg Co (1,0 – 100000) mg/kg Cr (1,0 – 100000) mg/kg Cu (1,0 – 100000) mg/kg Mn (1,0 – 100000) mg/kg Mo (1,0 – 100000) mg/kg Ni (1,0 – 100000) mg/kg Pb (1,0 – 100000) mg/kg Sb (1,0 – 100000) mg/kg Se (2,0 – 100000) mg/kg Sn (1,0 – 100000) mg/kg Zn (1,0 – 100000) mg/kg Inductively coupled plasma optical emission spectrometry method method (ICP-OES) SO-4/ZLGIG/PB.11 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.11 ed. 1st of 01/08/2025","categories":["materials","construction","environment"],"row_index":354,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building materials: mineral aggregates Elements content Range: As (1,0 – 100000) mg/kg Ba (1,0 – 100000) mg/kg Cd (1,0 – 100000) mg/kg Co (1,0 – 100000) mg/kg Cr (1,0 – 100000) mg/kg Cu (1,0 – 100000) mg/kg Mn (1,0 – 100000) mg/kg Mo (1,0 – 100000) mg/kg Ni (1,0 – 100000) mg/kg Pb (1,0 – 100000) mg/kg Sb (1,0 – 100000) mg/kg Se (2,0 – 100000) mg/kg Sn (1,0 – 100000) mg/kg Zn (1,0 – 100000) mg/kg Inductively coupled plasma optical emission spectrometry method method (ICP-OES) SO-4/ZLGIG/PB.11 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.11 ed. 1st of 01/08/2025","search_zh":"建筑材料：矿物集料 Building materials: mineral aggregates SO-4/ZLGIG/PB.11 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.11 ed. 1st of 01/08/2025","test_object_zh":"建筑材料：矿物集料 Building materials: mineral aggregates"},{"_id":"6a5a55ef9af9f73f38250bff","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Materiały budowlane: kruszywa mineralne Building materials: mineral aggregates","test_object_en":"Building materials: mineral aggregates","methodology":"Zawartość rtęci Zakres: (0,01 – 20) mg/kg Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry method with amalgamation","methodology_en":"Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry with the amalgamation technique Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry method with amalgamation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość rtęci Zakres: (0,01 – 20) mg/kg Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry method with amalgamation","reference":"SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1st of 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały budowlane: kruszywa mineralne Building materials: mineral aggregates Zawartość rtęci Zakres: (0,01 – 20) mg/kg Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry method with amalgamation SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1st of 01/08/2025 Materialy budowlane: kruszywa mineralne Building materials: mineral aggregates Zawartosc rteci Zakres: (0,01 – 20) mg/kg Metoda absorpcyjnej spektrometrii atomowej z technika amalgamacji Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry method with amalgamation SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1st of 01/08/2025","categories":["materials","construction"],"row_index":355,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building materials: mineral aggregates Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry with the amalgamation technique Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry method with amalgamation SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1st of 01/08/2025","search_zh":"建筑材料：矿物集料 Building materials: mineral aggregates 汞含量 范围：(0,01 – 20) mg/kg 汞齐化技术原子吸收光谱法 Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry method with amalgamation SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1st of 01/08/2025","test_object_zh":"建筑材料：矿物集料 Building materials: mineral aggregates","methodology_zh":"汞含量 范围：(0,01 – 20) mg/kg 汞齐化技术原子吸收光谱法 Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry method with amalgamation"},{"_id":"6a5a55ef9af9f73f38250c00","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Materiały budowlane: kruszywa mineralne Building materials: mineral aggregates","test_object_en":"Building materials: mineral aggregates","methodology":"Zawartość tlenków Zakres: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Oxides content Range: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","methodology_en":"Oxide content Range: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) Oxides content Range: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość tlenków Zakres: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Oxides content Range: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","reference":"SO-4/ZLGIG/PB.05 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.05 ed. 1st of 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.05 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.05 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały budowlane: kruszywa mineralne Building materials: mineral aggregates Zawartość tlenków Zakres: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Oxides content Range: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) SO-4/ZLGIG/PB.05 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.05 ed. 1st of 01/08/2025 Materialy budowlane: kruszywa mineralne Building materials: mineral aggregates Zawartosc tlenkow Zakres: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja fali (WD-XRF) Oxides content Range: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) SO-4/ZLGIG/PB.05 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.05 ed. 1st of 01/08/2025","categories":["materials","construction"],"row_index":356,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building materials: mineral aggregates Oxide content Range: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) Oxides content Range: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) SO-4/ZLGIG/PB.05 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.05 ed. 1st of 01/08/2025","search_zh":"建筑材料：矿物集料 Building materials: mineral aggregates 氧化物含量 范围：SiO2 (1,20 – 89,16) %m/m、Al2O3 (0,12 – 43,72) %m/m、Fe2O3 (0,29 – 70,72) %m/m、CaO (0,18 – 70,81) %m/m、MgO (0,15 – 23,51) %m/m、Na2O (0,01 – 10,52) %m/m、K2O (0,05 – 3,78) %m/m、SO3 (0,30 – 72,02) %m/m、TiO2 (0,01 – 3,25) %m/m、P2O5 (0,04 – 14,66) %m/m X射线荧光法 SO-4/ZLGIG/PB.05 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.05 ed. 1st of 01/08/2025","test_object_zh":"建筑材料：矿物集料 Building materials: mineral aggregates","methodology_zh":"氧化物含量 范围：SiO2 (1,20 – 89,16) %m/m、Al2O3 (0,12 – 43,72) %m/m、Fe2O3 (0,29 – 70,72) %m/m、CaO (0,18 – 70,81) %m/m、MgO (0,15 – 23,51) %m/m、Na2O (0,01 – 10,52) %m/m、K2O (0,05 – 3,78) %m/m、SO3 (0,30 – 72,02) %m/m、TiO2 (0,01 – 3,25) %m/m、P2O5 (0,04 – 14,66) %m/m X射线荧光法"},{"_id":"6a5a55ef9af9f73f38250c01","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Materiały budowlane: kruszywa mineralne Building materials: mineral aggregates","test_object_en":"Building materials: mineral aggregates","methodology":"Zawartość tlenków Zakres: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Oxides content Range: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD- XRF)","methodology_en":"Oxides content Range: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD- XRF)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość tlenków Zakres: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Oxides content Range: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD- XRF)","reference":"SO-4/ZLGIG/PB.24 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.24 ed. 1st of 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.24 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.24 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały budowlane: kruszywa mineralne Building materials: mineral aggregates Zawartość tlenków Zakres: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Oxides content Range: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD- XRF) SO-4/ZLGIG/PB.24 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.24 ed. 1st of 01/08/2025 Materialy budowlane: kruszywa mineralne Building materials: mineral aggregates Zawartosc tlenkow Zakres: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja fali (WD-XRF) Oxides content Range: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD- XRF) SO-4/ZLGIG/PB.24 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.24 ed. 1st of 01/08/2025","categories":["materials","construction"],"row_index":357,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building materials: mineral aggregates Oxides content Range: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD- XRF) SO-4/ZLGIG/PB.24 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.24 ed. 1st of 01/08/2025","search_zh":"建筑材料：矿物集料 Building materials: mineral aggregates SO-4/ZLGIG/PB.24 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.24 ed. 1st of 01/08/2025","test_object_zh":"建筑材料：矿物集料 Building materials: mineral aggregates"},{"_id":"6a5a55ef9af9f73f38250c02","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Grunty Ground","test_object_en":"Ground","methodology":"Zawartość wilgoci analitycznej Zakres: (0,10 – 10,0) %m/m Metoda wagowa Analytical moisture content Range: (0,10 – 10,0) %m/m Gravimetric method","methodology_en":"Analytical moisture content Range: (0,10 – 10,0) %m/m Gravimetric method Analytical moisture content Range: (0,10 – 10,0) %m/m Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci analitycznej Zakres: (0,10 – 10,0) %m/m Metoda wagowa Analytical moisture content Range: (0,10 – 10,0) %m/m Gravimetric method","reference":"SO-4/ZLGIG/PB.02 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.02 ed. 1st of 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.02 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.02 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Grunty Ground Zawartość wilgoci analitycznej Zakres: (0,10 – 10,0) %m/m Metoda wagowa Analytical moisture content Range: (0,10 – 10,0) %m/m Gravimetric method SO-4/ZLGIG/PB.02 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.02 ed. 1st of 01/08/2025 Grunty Ground Zawartosc wilgoci analitycznej Zakres: (0,10 – 10,0) %m/m Metoda wagowa Analytical moisture content Range: (0,10 – 10,0) %m/m Gravimetric method SO-4/ZLGIG/PB.02 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.02 ed. 1st of 01/08/2025","categories":["other"],"row_index":358,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ground Analytical moisture content Range: (0,10 – 10,0) %m/m Gravimetric method Analytical moisture content Range: (0,10 – 10,0) %m/m Gravimetric method SO-4/ZLGIG/PB.02 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.02 ed. 1st of 01/08/2025","search_zh":"土体 Ground SO-4/ZLGIG/PB.02 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.02 ed. 1st of 01/08/2025","test_object_zh":"土体 Ground"},{"_id":"6a5a55ef9af9f73f38250c03","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Grunty Ground","test_object_en":"Ground","methodology":"Zawartość popiołu Zakres: (15,00 – 99,00) %m/m Metoda wagowa Zawartość strat prażenia (z obliczeń) Ash content Range: (35,00 – 99,00) %m/m Gravimetric method Loss on ignition (from calculations)","methodology_en":"Ash content Range: (35,00 – 99,00) %m/m Gravimetric method Loss on ignition (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość popiołu Zakres: (15,00 – 99,00) %m/m Metoda wagowa Zawartość strat prażenia (z obliczeń) Ash content Range: (35,00 – 99,00) %m/m Gravimetric method Loss on ignition (from calculations)","reference":"SO-4/ZLGIG/PB.03 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.03 ed. 1st of 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.03 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.03 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Grunty Ground Zawartość popiołu Zakres: (15,00 – 99,00) %m/m Metoda wagowa Zawartość strat prażenia (z obliczeń) Ash content Range: (35,00 – 99,00) %m/m Gravimetric method Loss on ignition (from calculations) SO-4/ZLGIG/PB.03 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.03 ed. 1st of 01/08/2025 Grunty Ground Zawartosc popiolu Zakres: (15,00 – 99,00) %m/m Metoda wagowa Zawartosc strat prazenia (z obliczen) Ash content Range: (35,00 – 99,00) %m/m Gravimetric method Loss on ignition (from calculations) SO-4/ZLGIG/PB.03 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.03 ed. 1st of 01/08/2025","categories":["other"],"row_index":359,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ground Ash content Range: (35,00 – 99,00) %m/m Gravimetric method Loss on ignition (from calculations) SO-4/ZLGIG/PB.03 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.03 ed. 1st of 01/08/2025","search_zh":"土体 Ground SO-4/ZLGIG/PB.03 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.03 ed. 1st of 01/08/2025","test_object_zh":"土体 Ground"},{"_id":"6a5a55ef9af9f73f38250c04","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Grunty Ground","test_object_en":"Ground","methodology":"Zawartość tlenków Zakres: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Oxides content Range: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","methodology_en":"Oxide content Range: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) Oxides content Range: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość tlenków Zakres: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Oxides content Range: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","reference":"SO-4/ZLGIG/PB.05 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.05 ed. 1st of 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.05 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.05 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Grunty Ground Zawartość tlenków Zakres: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Oxides content Range: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) SO-4/ZLGIG/PB.05 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.05 ed. 1st of 01/08/2025 Grunty Ground Zawartosc tlenkow Zakres: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja fali (WD-XRF) Oxides content Range: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) SO-4/ZLGIG/PB.05 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.05 ed. 1st of 01/08/2025","categories":["other"],"row_index":360,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ground Oxide content Range: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) Oxides content Range: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) SO-4/ZLGIG/PB.05 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.05 ed. 1st of 01/08/2025","search_zh":"土体 Ground 氧化物含量 范围：SiO2 (1,20 – 89,16) %m/m、Al2O3 (0,12 – 43,72) %m/m、Fe2O3 (0,29 – 70,72) %m/m、CaO (0,18 – 70,81) %m/m、MgO (0,15 – 23,51) %m/m、Na2O (0,01 – 10,52) %m/m、K2O (0,05 – 3,78) %m/m、SO3 (0,30 – 72,02) %m/m、TiO2 (0,01 – 3,25) %m/m、P2O5 (0,04 – 14,66) %m/m X射线荧光法 SO-4/ZLGIG/PB.05 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.05 ed. 1st of 01/08/2025","test_object_zh":"土体 Ground","methodology_zh":"氧化物含量 范围：SiO2 (1,20 – 89,16) %m/m、Al2O3 (0,12 – 43,72) %m/m、Fe2O3 (0,29 – 70,72) %m/m、CaO (0,18 – 70,81) %m/m、MgO (0,15 – 23,51) %m/m、Na2O (0,01 – 10,52) %m/m、K2O (0,05 – 3,78) %m/m、SO3 (0,30 – 72,02) %m/m、TiO2 (0,01 – 3,25) %m/m、P2O5 (0,04 – 14,66) %m/m X射线荧光法"},{"_id":"6a5a55ef9af9f73f38250c05","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Grunty Ground","test_object_en":"Ground","methodology":"Zawartość tlenków Zakres: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Oxides content Range: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","methodology_en":"Oxides content Range: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) Oxides content Range: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość tlenków Zakres: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Oxides content Range: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","reference":"SO-4/ZLGIG/PB.24 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.24 ed. 1st of 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.24 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.24 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Grunty Ground Zawartość tlenków Zakres: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Oxides content Range: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) SO-4/ZLGIG/PB.24 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.24 ed. 1st of 01/08/2025 Grunty Ground Zawartosc tlenkow Zakres: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja fali (WD-XRF) Oxides content Range: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) SO-4/ZLGIG/PB.24 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.24 ed. 1st of 01/08/2025","categories":["other"],"row_index":361,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ground Oxides content Range: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) Oxides content Range: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) SO-4/ZLGIG/PB.24 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.24 ed. 1st of 01/08/2025","search_zh":"土体 Ground SO-4/ZLGIG/PB.24 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.24 ed. 1st of 01/08/2025","test_object_zh":"土体 Ground"},{"_id":"6a5a55ef9af9f73f38250c06","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Grunty Ground","test_object_en":"Ground","methodology":"Zawartość pierwiastków Zakres: As (1,0 – 100000) mg/kg Ba (1,0 – 100000) mg/kg Cd (1,0 – 100000) mg/kg Co (1,0 – 100000) mg/kg Cr (1,0 – 100000) mg/kg Cu (1,0 – 100000) mg/kg Mn (1,0 – 100000) mg/kg Mo (1,0 – 100000) mg/kg Ni (1,0 – 100000) mg/kg Pb (1,0 – 100000) mg/kg Sb (1,0 – 100000) mg/kg Se (2,0 – 100000) mg/kg Sn (1,0 – 100000) mg/kg Zn (1,0 – 100000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Content of elements Range: As (1,0 – 100000) mg/kg Ba (1,0 – 100000) mg/kg Cd (1,0 – 100000) mg/kg Co (1,0 – 100000) mg/kg Cr (1,0 – 100000) mg/kg Cu (1,0 – 100000) mg/kg Mn (1,0 – 100000) mg/kg Mo (1,0 – 100000) mg/kg Ni (1,0 – 100000) mg/kg Pb (1,0 – 100000) mg/kg Sb (1,0 – 100000) mg/kg Se (2,0 – 100000) mg/kg Sn (1,0 – 100000) mg/kg Zn (1,0 – 100000) mg/kg Inductively coupled plasma optical emission spectrometry method (ICP-OES)","methodology_en":"Content of elements Range: As (1,0 – 100000) mg/kg Ba (1,0 – 100000) mg/kg Cd (1,0 – 100000) mg/kg Co (1,0 – 100000) mg/kg Cr (1,0 – 100000) mg/kg Cu (1,0 – 100000) mg/kg Mn (1,0 – 100000) mg/kg Mo (1,0 – 100000) mg/kg Ni (1,0 – 100000) mg/kg Pb (1,0 – 100000) mg/kg Sb (1,0 – 100000) mg/kg Se (2,0 – 100000) mg/kg Sn (1,0 – 100000) mg/kg Zn (1,0 – 100000) mg/kg Inductively coupled plasma optical emission spectrometry method (ICP-OES)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość pierwiastków Zakres: As (1,0 – 100000) mg/kg Ba (1,0 – 100000) mg/kg Cd (1,0 – 100000) mg/kg Co (1,0 – 100000) mg/kg Cr (1,0 – 100000) mg/kg Cu (1,0 – 100000) mg/kg Mn (1,0 – 100000) mg/kg Mo (1,0 – 100000) mg/kg Ni (1,0 – 100000) mg/kg Pb (1,0 – 100000) mg/kg Sb (1,0 – 100000) mg/kg Se (2,0 – 100000) mg/kg Sn (1,0 – 100000) mg/kg Zn (1,0 – 100000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Content of elements Range: As (1,0 – 100000) mg/kg Ba (1,0 – 100000) mg/kg Cd (1,0 – 100000) mg/kg Co (1,0 – 100000) mg/kg Cr (1,0 – 100000) mg/kg Cu (1,0 – 100000) mg/kg Mn (1,0 – 100000) mg/kg Mo (1,0 – 100000) mg/kg Ni (1,0 – 100000) mg/kg Pb (1,0 – 100000) mg/kg Sb (1,0 – 100000) mg/kg Se (2,0 – 100000) mg/kg Sn (1,0 – 100000) mg/kg Zn (1,0 – 100000) mg/kg Inductively coupled plasma optical emission spectrometry method (ICP-OES)","reference":"SO-4/ZLGIG/PB.11 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.11 ed. 1st of 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.11 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.11 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Grunty Ground Zawartość pierwiastków Zakres: As (1,0 – 100000) mg/kg Ba (1,0 – 100000) mg/kg Cd (1,0 – 100000) mg/kg Co (1,0 – 100000) mg/kg Cr (1,0 – 100000) mg/kg Cu (1,0 – 100000) mg/kg Mn (1,0 – 100000) mg/kg Mo (1,0 – 100000) mg/kg Ni (1,0 – 100000) mg/kg Pb (1,0 – 100000) mg/kg Sb (1,0 – 100000) mg/kg Se (2,0 – 100000) mg/kg Sn (1,0 – 100000) mg/kg Zn (1,0 – 100000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Content of elements Range: As (1,0 – 100000) mg/kg Ba (1,0 – 100000) mg/kg Cd (1,0 – 100000) mg/kg Co (1,0 – 100000) mg/kg Cr (1,0 – 100000) mg/kg Cu (1,0 – 100000) mg/kg Mn (1,0 – 100000) mg/kg Mo (1,0 – 100000) mg/kg Ni (1,0 – 100000) mg/kg Pb (1,0 – 100000) mg/kg Sb (1,0 – 100000) mg/kg Se (2,0 – 100000) mg/kg Sn (1,0 – 100000) mg/kg Zn (1,0 – 100000) mg/kg Inductively coupled plasma optical emission spectrometry method (ICP-OES) SO-4/ZLGIG/PB.11 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.11 ed. 1st of 01/08/2025 Grunty Ground Zawartosc pierwiastkow Zakres: As (1,0 – 100000) mg/kg Ba (1,0 – 100000) mg/kg Cd (1,0 – 100000) mg/kg Co (1,0 – 100000) mg/kg Cr (1,0 – 100000) mg/kg Cu (1,0 – 100000) mg/kg Mn (1,0 – 100000) mg/kg Mo (1,0 – 100000) mg/kg Ni (1,0 – 100000) mg/kg Pb (1,0 – 100000) mg/kg Sb (1,0 – 100000) mg/kg Se (2,0 – 100000) mg/kg Sn (1,0 – 100000) mg/kg Zn (1,0 – 100000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Content of elements Range: As (1,0 – 100000) mg/kg Ba (1,0 – 100000) mg/kg Cd (1,0 – 100000) mg/kg Co (1,0 – 100000) mg/kg Cr (1,0 – 100000) mg/kg Cu (1,0 – 100000) mg/kg Mn (1,0 – 100000) mg/kg Mo (1,0 – 100000) mg/kg Ni (1,0 – 100000) mg/kg Pb (1,0 – 100000) mg/kg Sb (1,0 – 100000) mg/kg Se (2,0 – 100000) mg/kg Sn (1,0 – 100000) mg/kg Zn (1,0 – 100000) mg/kg Inductively coupled plasma optical emission spectrometry method (ICP-OES) SO-4/ZLGIG/PB.11 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.11 ed. 1st of 01/08/2025","categories":["environment"],"row_index":362,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ground Content of elements Range: As (1,0 – 100000) mg/kg Ba (1,0 – 100000) mg/kg Cd (1,0 – 100000) mg/kg Co (1,0 – 100000) mg/kg Cr (1,0 – 100000) mg/kg Cu (1,0 – 100000) mg/kg Mn (1,0 – 100000) mg/kg Mo (1,0 – 100000) mg/kg Ni (1,0 – 100000) mg/kg Pb (1,0 – 100000) mg/kg Sb (1,0 – 100000) mg/kg Se (2,0 – 100000) mg/kg Sn (1,0 – 100000) mg/kg Zn (1,0 – 100000) mg/kg Inductively coupled plasma optical emission spectrometry method (ICP-OES) SO-4/ZLGIG/PB.11 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.11 ed. 1st of 01/08/2025","search_zh":"土体 Ground SO-4/ZLGIG/PB.11 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.11 ed. 1st of 01/08/2025","test_object_zh":"土体 Ground"},{"_id":"6a5a55ef9af9f73f38250c07","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Grunty Ground","test_object_en":"Ground","methodology":"Zawartość rtęci Zakres: (0,01 – 20) mg/kg Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry method with amalgamation","methodology_en":"Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry with the amalgamation technique Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry method with amalgamation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość rtęci Zakres: (0,01 – 20) mg/kg Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry method with amalgamation","reference":"SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1st of 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Grunty Ground Zawartość rtęci Zakres: (0,01 – 20) mg/kg Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry method with amalgamation SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1st of 01/08/2025 Grunty Ground Zawartosc rteci Zakres: (0,01 – 20) mg/kg Metoda absorpcyjnej spektrometrii atomowej z technika amalgamacji Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry method with amalgamation SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1st of 01/08/2025","categories":["other"],"row_index":363,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ground Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry with the amalgamation technique Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry method with amalgamation SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1st of 01/08/2025","search_zh":"土体 Ground 汞含量 范围：(0,01 – 20) mg/kg 汞齐化技术原子吸收光谱法 Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry method with amalgamation SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1st of 01/08/2025","test_object_zh":"土体 Ground","methodology_zh":"汞含量 范围：(0,01 – 20) mg/kg 汞齐化技术原子吸收光谱法 Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry method with amalgamation"},{"_id":"6a5a55ef9af9f73f38250c08","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Grunty Ground","test_object_en":"Ground","methodology":"Zawartość węgla nieorganicznego (TIC) Zakres: (0,10 – 12,00) %m/m Metoda spektrometrii w zakresie podczerwieni (IR) Total Inorganic Carbon content (TIC) Range: (0,10 – 12,00) %m/m IR spectrometry method","methodology_en":"Total Inorganic Carbon content (TIC) Range: (0,10 – 12,00) %m/m IR spectrometry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość węgla nieorganicznego (TIC) Zakres: (0,10 – 12,00) %m/m Metoda spektrometrii w zakresie podczerwieni (IR) Total Inorganic Carbon content (TIC) Range: (0,10 – 12,00) %m/m IR spectrometry method","reference":"PN-EN 15936:2022-07 PN-EN 15936:2022-07","norm_bases":["PN-EN 15936:2022-07 PN-EN 15936:2022-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Grunty Ground Zawartość węgla nieorganicznego (TIC) Zakres: (0,10 – 12,00) %m/m Metoda spektrometrii w zakresie podczerwieni (IR) Total Inorganic Carbon content (TIC) Range: (0,10 – 12,00) %m/m IR spectrometry method PN-EN 15936:2022-07 PN-EN 15936:2022-07 Grunty Ground Zawartosc wegla nieorganicznego (TIC) Zakres: (0,10 – 12,00) %m/m Metoda spektrometrii w zakresie podczerwieni (IR) Total Inorganic Carbon content (TIC) Range: (0,10 – 12,00) %m/m IR spectrometry method PN-EN 15936:2022-07 PN-EN 15936:2022-07","categories":["other"],"row_index":364,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ground Total Inorganic Carbon content (TIC) Range: (0,10 – 12,00) %m/m IR spectrometry method PN-EN 15936:2022-07 PN-EN 15936:2022-07","search_zh":"土体 Ground PN-EN 15936:2022-07 PN-EN 15936:2022-07","test_object_zh":"土体 Ground"},{"_id":"6a5a55ef9af9f73f38250c09","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Grunty Ground","test_object_en":"Ground","methodology":"Zawartość węgla całkowitego Zakres: (0,10 – 48,00) %m/m Metoda wysokotemperaturowego spalania z detekcją IR Zawartość węgla organicznego (TOC) (z obliczeń) Total carbon (TC) content Range: (0,10 – 48,00) %m/m High temp. combustion method with IR detection Organic carbon (TOC) content (from calculations)","methodology_en":"Total carbon (TC) content Range: (0,10 – 48,00) %m/m High temp. combustion method with IR detection Organic carbon (TOC) content (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego Zakres: (0,10 – 48,00) %m/m Metoda wysokotemperaturowego spalania z detekcją IR Zawartość węgla organicznego (TOC) (z obliczeń) Total carbon (TC) content Range: (0,10 – 48,00) %m/m High temp. combustion method with IR detection Organic carbon (TOC) content (from calculations)","reference":"PN-ISO 10694:2002","norm_bases":["PN-ISO 10694:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Grunty Ground Zawartość węgla całkowitego Zakres: (0,10 – 48,00) %m/m Metoda wysokotemperaturowego spalania z detekcją IR Zawartość węgla organicznego (TOC) (z obliczeń) Total carbon (TC) content Range: (0,10 – 48,00) %m/m High temp. combustion method with IR detection Organic carbon (TOC) content (from calculations) PN-ISO 10694:2002 Grunty Ground Zawartosc wegla calkowitego Zakres: (0,10 – 48,00) %m/m Metoda wysokotemperaturowego spalania z detekcja IR Zawartosc wegla organicznego (TOC) (z obliczen) Total carbon (TC) content Range: (0,10 – 48,00) %m/m High temp. combustion method with IR detection Organic carbon (TOC) content (from calculations) PN-ISO 10694:2002","categories":["other"],"row_index":365,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ground Total carbon (TC) content Range: (0,10 – 48,00) %m/m High temp. combustion method with IR detection Organic carbon (TOC) content (from calculations) PN-ISO 10694:2002","search_zh":"土体 Ground PN-ISO 10694:2002","test_object_zh":"土体 Ground"},{"_id":"6a5a55ef9af9f73f38250c0a","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Grunty Ground","test_object_en":"Ground","methodology":"Zawartość siarki całkowitej Zakres: (0,03 – 0,50) %m/m Metoda wysokotemperaturowego spalania z detekcją IR Total sulphur (TS) content Range: (0,03 – 0,50) %m/m High temp. combustion method with IR detection","methodology_en":"Total sulphur (TS) content Range: (0,03 – 0,50) %m/m High temp. combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej Zakres: (0,03 – 0,50) %m/m Metoda wysokotemperaturowego spalania z detekcją IR Total sulphur (TS) content Range: (0,03 – 0,50) %m/m High temp. combustion method with IR detection","reference":"PN-ISO 15178:2004","norm_bases":["PN-ISO 15178:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Grunty Ground Zawartość siarki całkowitej Zakres: (0,03 – 0,50) %m/m Metoda wysokotemperaturowego spalania z detekcją IR Total sulphur (TS) content Range: (0,03 – 0,50) %m/m High temp. combustion method with IR detection PN-ISO 15178:2004 Grunty Ground Zawartosc siarki calkowitej Zakres: (0,03 – 0,50) %m/m Metoda wysokotemperaturowego spalania z detekcja IR Total sulphur (TS) content Range: (0,03 – 0,50) %m/m High temp. combustion method with IR detection PN-ISO 15178:2004","categories":["other"],"row_index":366,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ground Total sulphur (TS) content Range: (0,03 – 0,50) %m/m High temp. combustion method with IR detection PN-ISO 15178:2004","search_zh":"土体 Ground PN-ISO 15178:2004","test_object_zh":"土体 Ground"},{"_id":"6a5a55ef9af9f73f38250c0b","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Grunty Ground","test_object_en":"Ground","methodology":"Skład granulometryczny w zakresie cząstek: (2 – 2000) μm Zakres: (1 – 99) % Metoda dyfrakcji laserowej Particle size distribution in the range (2 – 2000) μm Range: (1 – 99) % Laser diffraction method","methodology_en":"Particle size distribution in the particle range: (2 – 2000) μm Range: (1 – 99) % Laser diffraction method Particle size distribution in the range (2 – 2000) μm Range: (1 – 99) % Laser diffraction method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skład granulometryczny w zakresie cząstek: (2 – 2000) μm Zakres: (1 – 99) % Metoda dyfrakcji laserowej Particle size distribution in the range (2 – 2000) μm Range: (1 – 99) % Laser diffraction method","reference":"ISO 13320:2020","norm_bases":["ISO 13320:2020"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Grunty Ground Skład granulometryczny w zakresie cząstek: (2 – 2000) μm Zakres: (1 – 99) % Metoda dyfrakcji laserowej Particle size distribution in the range (2 – 2000) μm Range: (1 – 99) % Laser diffraction method ISO 13320:2020 Grunty Ground Sklad granulometryczny w zakresie czastek: (2 – 2000) μm Zakres: (1 – 99) % Metoda dyfrakcji laserowej Particle size distribution in the range (2 – 2000) μm Range: (1 – 99) % Laser diffraction method ISO 13320:2020","categories":["other"],"row_index":367,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ground Particle size distribution in the particle range: (2 – 2000) μm Range: (1 – 99) % Laser diffraction method Particle size distribution in the range (2 – 2000) μm Range: (1 – 99) % Laser diffraction method ISO 13320:2020","search_zh":"土体 Ground ISO 13320:2020","test_object_zh":"土体 Ground"},{"_id":"6a5a55ef9af9f73f38250c0c","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Grunty Ground","test_object_en":"Ground","methodology":"Skład granulometryczny w zakresie cząstek: (2,0 – 8,0) mm Zakres: (1 – 90) % Metoda sitowo-wagowa Particle size distribution in the range (2,0 – 8,0) mm Range: (1 – 90) % Sieve-gravimetric method","methodology_en":"Particle size distribution in the particle range: (2,0 – 8,0) mm Range: (1 – 90) % Sieve-gravimetric method Particle size distribution in the range (2,0 – 8,0) mm Range: (1 – 90) % Sieve-gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skład granulometryczny w zakresie cząstek: (2,0 – 8,0) mm Zakres: (1 – 90) % Metoda sitowo-wagowa Particle size distribution in the range (2,0 – 8,0) mm Range: (1 – 90) % Sieve-gravimetric method","reference":"PN-ISO 11277:2005","norm_bases":["PN-ISO 11277:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Grunty Ground Skład granulometryczny w zakresie cząstek: (2,0 – 8,0) mm Zakres: (1 – 90) % Metoda sitowo-wagowa Particle size distribution in the range (2,0 – 8,0) mm Range: (1 – 90) % Sieve-gravimetric method PN-ISO 11277:2005 Grunty Ground Sklad granulometryczny w zakresie czastek: (2,0 – 8,0) mm Zakres: (1 – 90) % Metoda sitowo-wagowa Particle size distribution in the range (2,0 – 8,0) mm Range: (1 – 90) % Sieve-gravimetric method PN-ISO 11277:2005","categories":["other"],"row_index":368,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ground Particle size distribution in the particle range: (2,0 – 8,0) mm Range: (1 – 90) % Sieve-gravimetric method Particle size distribution in the range (2,0 – 8,0) mm Range: (1 – 90) % Sieve-gravimetric method PN-ISO 11277:2005","search_zh":"土体 Ground PN-ISO 11277:2005","test_object_zh":"土体 Ground"},{"_id":"6a5a55ef9af9f73f38250c0d","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Grunty Ground","test_object_en":"Ground","methodology":"pH - w KCl, pH - w H O 2 Zakres: 2,0 – 12,0 Metoda potencjometryczna pH value - in KCl, pH value - in H O 2 Range: 2,0 – 12,0 Potentiometric method","methodology_en":"pH - in KCl, pH - in H O 2 Range: 2,0 – 12,0 Potentiometric method pH value - in KCl, pH value - in H O 2 Range: 2,0 – 12,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH - w KCl, pH - w H O 2 Zakres: 2,0 – 12,0 Metoda potencjometryczna pH value - in KCl, pH value - in H O 2 Range: 2,0 – 12,0 Potentiometric method","reference":"PN-ISO 10390:2022-09","norm_bases":["PN-ISO 10390:2022-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Grunty Ground pH - w KCl, pH - w H O 2 Zakres: 2,0 – 12,0 Metoda potencjometryczna pH value - in KCl, pH value - in H O 2 Range: 2,0 – 12,0 Potentiometric method PN-ISO 10390:2022-09 Grunty Ground pH - w KCl, pH - w H O 2 Zakres: 2,0 – 12,0 Metoda potencjometryczna pH value - in KCl, pH value - in H O 2 Range: 2,0 – 12,0 Potentiometric method PN-ISO 10390:2022-09","categories":["other"],"row_index":369,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ground pH - in KCl, pH - in H O 2 Range: 2,0 – 12,0 Potentiometric method pH value - in KCl, pH value - in H O 2 Range: 2,0 – 12,0 Potentiometric method PN-ISO 10390:2022-09","search_zh":"土体 Ground PN-ISO 10390:2022-09","test_object_zh":"土体 Ground"},{"_id":"6a5a55ef9af9f73f38250c0e","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Gleba Soil","test_object_en":"Soil","methodology":"Zawartość pierwiastków: Zakres: As (1,0 – 2000) mg/kg Ba (2,0 – 6000) mg/kg Cd (1,0 – 2000) mg/kg Co (1,0 – 2000) mg/kg Cr (1,0 – 2000) mg/kg Cu (1,0 – 2000) mg/kg Mo (1,0 – 2000) mg/kg Ni (1,0 – 2000) mg/kg Pb (1,0 – 2000) mg/kg Sn (1,0 – 2000) mg/kg Zn (1,0 – 6000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Content of elements Range: As (1,0 – 2000) mg/kg Ba (2,0 – 6000) mg/kg Cd (1,0 – 2000) mg/kg Co (1,0 – 2000) mg/kg Cr (1,0 – 2000) mg/kg Cu (1,0 – 2000) mg/kg Mo (1,0 – 2000) mg/kg Ni (1,0 – 2000) mg/kg Pb (1,0 – 2000) mg/kg Sn (1,0 – 2000) mg/kg Zn (1,0 – 6000) mg/kg Inductively coupled plasma optical emission spectrometry method (ICP-OES)","methodology_en":"Content of elements Range: As (1,0 – 2000) mg/kg Ba (2,0 – 6000) mg/kg Cd (1,0 – 2000) mg/kg Co (1,0 – 2000) mg/kg Cr (1,0 – 2000) mg/kg Cu (1,0 – 2000) mg/kg Mo (1,0 – 2000) mg/kg Ni (1,0 – 2000) mg/kg Pb (1,0 – 2000) mg/kg Sn (1,0 – 2000) mg/kg Zn (1,0 – 6000) mg/kg Inductively coupled plasma optical emission spectrometry method (ICP-OES)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość pierwiastków: Zakres: As (1,0 – 2000) mg/kg Ba (2,0 – 6000) mg/kg Cd (1,0 – 2000) mg/kg Co (1,0 – 2000) mg/kg Cr (1,0 – 2000) mg/kg Cu (1,0 – 2000) mg/kg Mo (1,0 – 2000) mg/kg Ni (1,0 – 2000) mg/kg Pb (1,0 – 2000) mg/kg Sn (1,0 – 2000) mg/kg Zn (1,0 – 6000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Content of elements Range: As (1,0 – 2000) mg/kg Ba (2,0 – 6000) mg/kg Cd (1,0 – 2000) mg/kg Co (1,0 – 2000) mg/kg Cr (1,0 – 2000) mg/kg Cu (1,0 – 2000) mg/kg Mo (1,0 – 2000) mg/kg Ni (1,0 – 2000) mg/kg Pb (1,0 – 2000) mg/kg Sn (1,0 – 2000) mg/kg Zn (1,0 – 6000) mg/kg Inductively coupled plasma optical emission spectrometry method (ICP-OES)","reference":"PN-EN 16174:2012 PN-EN ISO 11885:2009","norm_bases":["PN-EN 16174:2012 PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Soil Zawartość pierwiastków: Zakres: As (1,0 – 2000) mg/kg Ba (2,0 – 6000) mg/kg Cd (1,0 – 2000) mg/kg Co (1,0 – 2000) mg/kg Cr (1,0 – 2000) mg/kg Cu (1,0 – 2000) mg/kg Mo (1,0 – 2000) mg/kg Ni (1,0 – 2000) mg/kg Pb (1,0 – 2000) mg/kg Sn (1,0 – 2000) mg/kg Zn (1,0 – 6000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Content of elements Range: As (1,0 – 2000) mg/kg Ba (2,0 – 6000) mg/kg Cd (1,0 – 2000) mg/kg Co (1,0 – 2000) mg/kg Cr (1,0 – 2000) mg/kg Cu (1,0 – 2000) mg/kg Mo (1,0 – 2000) mg/kg Ni (1,0 – 2000) mg/kg Pb (1,0 – 2000) mg/kg Sn (1,0 – 2000) mg/kg Zn (1,0 – 6000) mg/kg Inductively coupled plasma optical emission spectrometry method (ICP-OES) PN-EN 16174:2012 PN-EN ISO 11885:2009 Gleba Soil Zawartosc pierwiastkow: Zakres: As (1,0 – 2000) mg/kg Ba (2,0 – 6000) mg/kg Cd (1,0 – 2000) mg/kg Co (1,0 – 2000) mg/kg Cr (1,0 – 2000) mg/kg Cu (1,0 – 2000) mg/kg Mo (1,0 – 2000) mg/kg Ni (1,0 – 2000) mg/kg Pb (1,0 – 2000) mg/kg Sn (1,0 – 2000) mg/kg Zn (1,0 – 6000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Content of elements Range: As (1,0 – 2000) mg/kg Ba (2,0 – 6000) mg/kg Cd (1,0 – 2000) mg/kg Co (1,0 – 2000) mg/kg Cr (1,0 – 2000) mg/kg Cu (1,0 – 2000) mg/kg Mo (1,0 – 2000) mg/kg Ni (1,0 – 2000) mg/kg Pb (1,0 – 2000) mg/kg Sn (1,0 – 2000) mg/kg Zn (1,0 – 6000) mg/kg Inductively coupled plasma optical emission spectrometry method (ICP-OES) PN-EN 16174:2012 PN-EN ISO 11885:2009","categories":["environment"],"row_index":370,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Content of elements Range: As (1,0 – 2000) mg/kg Ba (2,0 – 6000) mg/kg Cd (1,0 – 2000) mg/kg Co (1,0 – 2000) mg/kg Cr (1,0 – 2000) mg/kg Cu (1,0 – 2000) mg/kg Mo (1,0 – 2000) mg/kg Ni (1,0 – 2000) mg/kg Pb (1,0 – 2000) mg/kg Sn (1,0 – 2000) mg/kg Zn (1,0 – 6000) mg/kg Inductively coupled plasma optical emission spectrometry method (ICP-OES) PN-EN 16174:2012 PN-EN ISO 11885:2009","search_zh":"土壤 Soil PN-EN 16174:2012 PN-EN ISO 11885:2009","test_object_zh":"土壤 Soil"},{"_id":"6a5a55ef9af9f73f38250c0f","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Gleba Soil","test_object_en":"Soil","methodology":"Zawartość rtęci Zakres: (0,005 – 2,0) mg/kg Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji Mercury content Range: (0,005 – 2,0) mg/kg Atomic absorption spectrometry method with amalgamation","methodology_en":"Mercury content Range: (0,005 – 2,0) mg/kg Atomic absorption spectrometry method with amalgamation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość rtęci Zakres: (0,005 – 2,0) mg/kg Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji Mercury content Range: (0,005 – 2,0) mg/kg Atomic absorption spectrometry method with amalgamation","reference":"SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1st of 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Soil Zawartość rtęci Zakres: (0,005 – 2,0) mg/kg Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji Mercury content Range: (0,005 – 2,0) mg/kg Atomic absorption spectrometry method with amalgamation SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1st of 01/08/2025 Gleba Soil Zawartosc rteci Zakres: (0,005 – 2,0) mg/kg Metoda absorpcyjnej spektrometrii atomowej z technika amalgamacji Mercury content Range: (0,005 – 2,0) mg/kg Atomic absorption spectrometry method with amalgamation SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1st of 01/08/2025","categories":["environment"],"row_index":371,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Mercury content Range: (0,005 – 2,0) mg/kg Atomic absorption spectrometry method with amalgamation SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1st of 01/08/2025","search_zh":"土壤 Soil SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1st of 01/08/2025","test_object_zh":"土壤 Soil"},{"_id":"6a5a55ef9af9f73f38250c10","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Gleba Soil","test_object_en":"Soil","methodology":"Zawartość węgla całkowitego Zakres: (0,10 – 48,00) %m/m Metoda wysokotemperaturowego spalania z detekcją IR Zawartość węgla organicznego (TOC) (z obliczeń) Total carbon (TC) content Range: (0,10 – 48,00) %m/m High temp. combustion method with IR detection Total Organic carbon (TOC) content (from calculations)","methodology_en":"Total carbon (TC) content Range: (0,10 – 48,00) %m/m High temp. combustion method with IR detection Total Organic carbon (TOC) content (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego Zakres: (0,10 – 48,00) %m/m Metoda wysokotemperaturowego spalania z detekcją IR Zawartość węgla organicznego (TOC) (z obliczeń) Total carbon (TC) content Range: (0,10 – 48,00) %m/m High temp. combustion method with IR detection Total Organic carbon (TOC) content (from calculations)","reference":"PN-ISO 10694:2002","norm_bases":["PN-ISO 10694:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Soil Zawartość węgla całkowitego Zakres: (0,10 – 48,00) %m/m Metoda wysokotemperaturowego spalania z detekcją IR Zawartość węgla organicznego (TOC) (z obliczeń) Total carbon (TC) content Range: (0,10 – 48,00) %m/m High temp. combustion method with IR detection Total Organic carbon (TOC) content (from calculations) PN-ISO 10694:2002 Gleba Soil Zawartosc wegla calkowitego Zakres: (0,10 – 48,00) %m/m Metoda wysokotemperaturowego spalania z detekcja IR Zawartosc wegla organicznego (TOC) (z obliczen) Total carbon (TC) content Range: (0,10 – 48,00) %m/m High temp. combustion method with IR detection Total Organic carbon (TOC) content (from calculations) PN-ISO 10694:2002","categories":["environment"],"row_index":372,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Total carbon (TC) content Range: (0,10 – 48,00) %m/m High temp. combustion method with IR detection Total Organic carbon (TOC) content (from calculations) PN-ISO 10694:2002","search_zh":"土壤 Soil PN-ISO 10694:2002","test_object_zh":"土壤 Soil"},{"_id":"6a5a55ef9af9f73f38250c11","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Gleba Soil","test_object_en":"Soil","methodology":"Zawartość węgla nieorganicznego (TIC) Zakres: (0,10 – 12,00) %m/m Metoda spektrometrii w zakresie podczerwieni (IR) Total Inorganic Carbon (TIC) content Range: (0,10 – 12,00) %m/m IR spectrometry method","methodology_en":"Total Inorganic Carbon (TIC) content Range: (0,10 – 12,00) %m/m IR spectrometry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość węgla nieorganicznego (TIC) Zakres: (0,10 – 12,00) %m/m Metoda spektrometrii w zakresie podczerwieni (IR) Total Inorganic Carbon (TIC) content Range: (0,10 – 12,00) %m/m IR spectrometry method","reference":"PN-EN 15936:2022-07 metoda A PN-EN 15936:2022-07 method A","norm_bases":["PN-EN 15936:2022-07 metoda A PN-EN 15936:2022-07 method A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Soil Zawartość węgla nieorganicznego (TIC) Zakres: (0,10 – 12,00) %m/m Metoda spektrometrii w zakresie podczerwieni (IR) Total Inorganic Carbon (TIC) content Range: (0,10 – 12,00) %m/m IR spectrometry method PN-EN 15936:2022-07 metoda A PN-EN 15936:2022-07 method A Gleba Soil Zawartosc wegla nieorganicznego (TIC) Zakres: (0,10 – 12,00) %m/m Metoda spektrometrii w zakresie podczerwieni (IR) Total Inorganic Carbon (TIC) content Range: (0,10 – 12,00) %m/m IR spectrometry method PN-EN 15936:2022-07 metoda A PN-EN 15936:2022-07 method A","categories":["environment"],"row_index":373,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Total Inorganic Carbon (TIC) content Range: (0,10 – 12,00) %m/m IR spectrometry method PN-EN 15936:2022-07 metoda A PN-EN 15936:2022-07 method A","search_zh":"土壤 Soil PN-EN 15936:2022-07 metoda A PN-EN 15936:2022-07 method A","test_object_zh":"土壤 Soil"},{"_id":"6a5a55ef9af9f73f38250c12","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Gleba Soil","test_object_en":"Soil","methodology":"Zawartość siarki całkowitej Zakres: (0,03 – 0,50) %m/m Metoda wysokotemperaturowego spalania z detekcją IR Total Sulfur (TS) content Range: (0,03 – 0,50) %m/m High temp. combustion method with IR detection","methodology_en":"Total Sulfur (TS) content Range: (0,03 – 0,50) %m/m High temp. combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej Zakres: (0,03 – 0,50) %m/m Metoda wysokotemperaturowego spalania z detekcją IR Total Sulfur (TS) content Range: (0,03 – 0,50) %m/m High temp. combustion method with IR detection","reference":"PN-ISO 15178:2004","norm_bases":["PN-ISO 15178:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Soil Zawartość siarki całkowitej Zakres: (0,03 – 0,50) %m/m Metoda wysokotemperaturowego spalania z detekcją IR Total Sulfur (TS) content Range: (0,03 – 0,50) %m/m High temp. combustion method with IR detection PN-ISO 15178:2004 Gleba Soil Zawartosc siarki calkowitej Zakres: (0,03 – 0,50) %m/m Metoda wysokotemperaturowego spalania z detekcja IR Total Sulfur (TS) content Range: (0,03 – 0,50) %m/m High temp. combustion method with IR detection PN-ISO 15178:2004","categories":["environment"],"row_index":374,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Total Sulfur (TS) content Range: (0,03 – 0,50) %m/m High temp. combustion method with IR detection PN-ISO 15178:2004","search_zh":"土壤 Soil PN-ISO 15178:2004","test_object_zh":"土壤 Soil"},{"_id":"6a5a55ef9af9f73f38250c13","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Gleba Soil","test_object_en":"Soil","methodology":"Skład granulometryczny w zakresie cząstek: (2 – 2000) μm Zakres: (1 – 99) % Metoda dyfrakcji laserowej Particle size distribution in the range (2 – 2000) μm Range: (1 – 99) % Laser diffraction method","methodology_en":"Particle size distribution in the particle range: (2 – 2000) μm Range: (1 – 99) % Laser diffraction method Particle size distribution in the range (2 – 2000) μm Range: (1 – 99) % Laser diffraction method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skład granulometryczny w zakresie cząstek: (2 – 2000) μm Zakres: (1 – 99) % Metoda dyfrakcji laserowej Particle size distribution in the range (2 – 2000) μm Range: (1 – 99) % Laser diffraction method","reference":"ISO 13320:2020","norm_bases":["ISO 13320:2020"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Soil Skład granulometryczny w zakresie cząstek: (2 – 2000) μm Zakres: (1 – 99) % Metoda dyfrakcji laserowej Particle size distribution in the range (2 – 2000) μm Range: (1 – 99) % Laser diffraction method ISO 13320:2020 Gleba Soil Sklad granulometryczny w zakresie czastek: (2 – 2000) μm Zakres: (1 – 99) % Metoda dyfrakcji laserowej Particle size distribution in the range (2 – 2000) μm Range: (1 – 99) % Laser diffraction method ISO 13320:2020","categories":["environment"],"row_index":375,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Particle size distribution in the particle range: (2 – 2000) μm Range: (1 – 99) % Laser diffraction method Particle size distribution in the range (2 – 2000) μm Range: (1 – 99) % Laser diffraction method ISO 13320:2020","search_zh":"土壤 Soil ISO 13320:2020","test_object_zh":"土壤 Soil"},{"_id":"6a5a55ef9af9f73f38250c14","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Gleba Soil","test_object_en":"Soil","methodology":"Skład granulometryczny w zakresie cząstek: (2,0 – 8,0) mm Zakres: (1 – 90) % Metoda sitowo-wagowa Particle size distribution in the range (2,0 – 8,0) mm Range: (1 – 90) % Sieve-gravimetric method","methodology_en":"Particle size distribution in the particle range: (2,0 – 8,0) mm Range: (1 – 90) % Sieve-gravimetric method Particle size distribution in the range (2,0 – 8,0) mm Range: (1 – 90) % Sieve-gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skład granulometryczny w zakresie cząstek: (2,0 – 8,0) mm Zakres: (1 – 90) % Metoda sitowo-wagowa Particle size distribution in the range (2,0 – 8,0) mm Range: (1 – 90) % Sieve-gravimetric method","reference":"PN-ISO 11277:2005","norm_bases":["PN-ISO 11277:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Soil Skład granulometryczny w zakresie cząstek: (2,0 – 8,0) mm Zakres: (1 – 90) % Metoda sitowo-wagowa Particle size distribution in the range (2,0 – 8,0) mm Range: (1 – 90) % Sieve-gravimetric method PN-ISO 11277:2005 Gleba Soil Sklad granulometryczny w zakresie czastek: (2,0 – 8,0) mm Zakres: (1 – 90) % Metoda sitowo-wagowa Particle size distribution in the range (2,0 – 8,0) mm Range: (1 – 90) % Sieve-gravimetric method PN-ISO 11277:2005","categories":["environment"],"row_index":376,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Particle size distribution in the particle range: (2,0 – 8,0) mm Range: (1 – 90) % Sieve-gravimetric method Particle size distribution in the range (2,0 – 8,0) mm Range: (1 – 90) % Sieve-gravimetric method PN-ISO 11277:2005","search_zh":"土壤 Soil PN-ISO 11277:2005","test_object_zh":"土壤 Soil"},{"_id":"6a5a55ef9af9f73f38250c15","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Gleba Soil","test_object_en":"Soil","methodology":"pH - w KCl, pH - w H O 2 Zakres: 2,0 – 12,0 Metoda potencjometryczna pH value - in KCl, pH value - in H O 2 Range: 2,0 – 12,0 Potentiometric method","methodology_en":"pH - in KCl, pH - in H O 2 Range: 2,0 – 12,0 Potentiometric method pH value - in KCl, pH value - in H O 2 Range: 2,0 – 12,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH - w KCl, pH - w H O 2 Zakres: 2,0 – 12,0 Metoda potencjometryczna pH value - in KCl, pH value - in H O 2 Range: 2,0 – 12,0 Potentiometric method","reference":"PN-ISO 10390:2022-09","norm_bases":["PN-ISO 10390:2022-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Soil pH - w KCl, pH - w H O 2 Zakres: 2,0 – 12,0 Metoda potencjometryczna pH value - in KCl, pH value - in H O 2 Range: 2,0 – 12,0 Potentiometric method PN-ISO 10390:2022-09 Gleba Soil pH - w KCl, pH - w H O 2 Zakres: 2,0 – 12,0 Metoda potencjometryczna pH value - in KCl, pH value - in H O 2 Range: 2,0 – 12,0 Potentiometric method PN-ISO 10390:2022-09","categories":["environment"],"row_index":377,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil pH - in KCl, pH - in H O 2 Range: 2,0 – 12,0 Potentiometric method pH value - in KCl, pH value - in H O 2 Range: 2,0 – 12,0 Potentiometric method PN-ISO 10390:2022-09","search_zh":"土壤 Soil PN-ISO 10390:2022-09","test_object_zh":"土壤 Soil"},{"_id":"6a5a55ef9af9f73f38250c16","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, paliwa stałe: paliwo wtórne – paliwo alternatywne Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel","test_object_en":"Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel","methodology":"Zawartość wilgoci analitycznej Zakres: (0,10 – 10,0) %m/m Metoda wagowa Analytical moisture Range: (0,10 – 10,0) %m/m Gravimetric method","methodology_en":"Analytical moisture Range: (0,10 – 10,0) %m/m Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci analitycznej Zakres: (0,10 – 10,0) %m/m Metoda wagowa Analytical moisture Range: (0,10 – 10,0) %m/m Gravimetric method","reference":"PN-EN ISO 21660-3:2021-08","norm_bases":["PN-EN ISO 21660-3:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, paliwa stałe: paliwo wtórne – paliwo alternatywne Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel Zawartość wilgoci analitycznej Zakres: (0,10 – 10,0) %m/m Metoda wagowa Analytical moisture Range: (0,10 – 10,0) %m/m Gravimetric method PN-EN ISO 21660-3:2021-08 Odpady O): kod 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, paliwa stale: paliwo wtorne – paliwo alternatywne Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel Zawartosc wilgoci analitycznej Zakres: (0,10 – 10,0) %m/m Metoda wagowa Analytical moisture Range: (0,10 – 10,0) %m/m Gravimetric method PN-EN ISO 21660-3:2021-08","categories":["environment","petro"],"row_index":378,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel Analytical moisture Range: (0,10 – 10,0) %m/m Gravimetric method PN-EN ISO 21660-3:2021-08","search_zh":"废物 O)：代码 19 08 05、19 12 01、19 12 04、19 12 06、19 12 07、19 12 08、19 12 10；固体燃料：再生燃料 － 替代燃料 Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel PN-EN ISO 21660-3:2021-08","test_object_zh":"废物 O)：代码 19 08 05、19 12 01、19 12 04、19 12 06、19 12 07、19 12 08、19 12 10；固体燃料：再生燃料 － 替代燃料 Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel"},{"_id":"6a5a55ef9af9f73f38250c17","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, paliwa stałe: paliwo wtórne – paliwo alternatywne Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel","test_object_en":"Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel","methodology":"Zawartość wilgoci całkowitej Zakres: (0,10 – 54,0) %m/m Metoda wagowa Total moisture content Range: (0,10 – 54,0) %m/m Gravimetric method","methodology_en":"Total moisture content Range: (0,10 – 54,0) %m/m Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej Zakres: (0,10 – 54,0) %m/m Metoda wagowa Total moisture content Range: (0,10 – 54,0) %m/m Gravimetric method","reference":"EN/TS 15414-1:2010 CEN/TS 15414-2:2010","norm_bases":["EN/TS 15414-1:2010 CEN/TS 15414-2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, paliwa stałe: paliwo wtórne – paliwo alternatywne Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel Zawartość wilgoci całkowitej Zakres: (0,10 – 54,0) %m/m Metoda wagowa Total moisture content Range: (0,10 – 54,0) %m/m Gravimetric method EN/TS 15414-1:2010 CEN/TS 15414-2:2010 Odpady O): kod 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, paliwa stale: paliwo wtorne – paliwo alternatywne Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel Zawartosc wilgoci calkowitej Zakres: (0,10 – 54,0) %m/m Metoda wagowa Total moisture content Range: (0,10 – 54,0) %m/m Gravimetric method EN/TS 15414-1:2010 CEN/TS 15414-2:2010","categories":["environment","petro"],"row_index":379,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel Total moisture content Range: (0,10 – 54,0) %m/m Gravimetric method EN/TS 15414-1:2010 CEN/TS 15414-2:2010","search_zh":"废物 O)：代码 19 08 05、19 12 01、19 12 04、19 12 06、19 12 07、19 12 08、19 12 10；固体燃料：再生燃料 － 替代燃料 Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel EN/TS 15414-1:2010 CEN/TS 15414-2:2010","test_object_zh":"废物 O)：代码 19 08 05、19 12 01、19 12 04、19 12 06、19 12 07、19 12 08、19 12 10；固体燃料：再生燃料 － 替代燃料 Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel"},{"_id":"6a5a55ef9af9f73f38250c18","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, paliwa stałe: paliwo wtórne – paliwo alternatywne Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel","test_object_en":"Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel","methodology":"Zawartość popiołu Zakres: (0,10 – 50,0) %m/m Metoda wagowa Zawartość strat prażenia (z obliczeń) Ash content Range: (0,10 – 50,0) %m/m Gravimetric method Loss on ignition (from calculations)","methodology_en":"Ash content Range: (0,10 – 50,0) %m/m Gravimetric method Loss on ignition (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość popiołu Zakres: (0,10 – 50,0) %m/m Metoda wagowa Zawartość strat prażenia (z obliczeń) Ash content Range: (0,10 – 50,0) %m/m Gravimetric method Loss on ignition (from calculations)","reference":"SO-4/ZLGIG/PB.03 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.03 ed. 1st of 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.03 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.03 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, paliwa stałe: paliwo wtórne – paliwo alternatywne Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel Zawartość popiołu Zakres: (0,10 – 50,0) %m/m Metoda wagowa Zawartość strat prażenia (z obliczeń) Ash content Range: (0,10 – 50,0) %m/m Gravimetric method Loss on ignition (from calculations) SO-4/ZLGIG/PB.03 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.03 ed. 1st of 01/08/2025 Odpady O): kod 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, paliwa stale: paliwo wtorne – paliwo alternatywne Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel Zawartosc popiolu Zakres: (0,10 – 50,0) %m/m Metoda wagowa Zawartosc strat prazenia (z obliczen) Ash content Range: (0,10 – 50,0) %m/m Gravimetric method Loss on ignition (from calculations) SO-4/ZLGIG/PB.03 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.03 ed. 1st of 01/08/2025","categories":["environment","petro"],"row_index":380,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel Ash content Range: (0,10 – 50,0) %m/m Gravimetric method Loss on ignition (from calculations) SO-4/ZLGIG/PB.03 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.03 ed. 1st of 01/08/2025","search_zh":"废物 O)：代码 19 08 05、19 12 01、19 12 04、19 12 06、19 12 07、19 12 08、19 12 10；固体燃料：再生燃料 － 替代燃料 Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel SO-4/ZLGIG/PB.03 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.03 ed. 1st of 01/08/2025","test_object_zh":"废物 O)：代码 19 08 05、19 12 01、19 12 04、19 12 06、19 12 07、19 12 08、19 12 10；固体燃料：再生燃料 － 替代燃料 Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel"},{"_id":"6a5a55ef9af9f73f38250c19","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, paliwa stałe: paliwo wtórne – paliwo alternatywne Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel","test_object_en":"Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel","methodology":"Zawartość popiołu Zakres: (0,50 – 50,0) %m/m Metoda wagowa Ash content Range: (0,50 – 50,0) %m/m Gravimetric method","methodology_en":"Ash content Range: (0,50 – 50,0) %m/m Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość popiołu Zakres: (0,50 – 50,0) %m/m Metoda wagowa Ash content Range: (0,50 – 50,0) %m/m Gravimetric method","reference":"PN-EN ISO 21656:2021-08","norm_bases":["PN-EN ISO 21656:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, paliwa stałe: paliwo wtórne – paliwo alternatywne Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel Zawartość popiołu Zakres: (0,50 – 50,0) %m/m Metoda wagowa Ash content Range: (0,50 – 50,0) %m/m Gravimetric method PN-EN ISO 21656:2021-08 Odpady O): kod 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, paliwa stale: paliwo wtorne – paliwo alternatywne Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel Zawartosc popiolu Zakres: (0,50 – 50,0) %m/m Metoda wagowa Ash content Range: (0,50 – 50,0) %m/m Gravimetric method PN-EN ISO 21656:2021-08","categories":["environment","petro"],"row_index":381,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel Ash content Range: (0,50 – 50,0) %m/m Gravimetric method PN-EN ISO 21656:2021-08","search_zh":"废物 O)：代码 19 08 05、19 12 01、19 12 04、19 12 06、19 12 07、19 12 08、19 12 10；固体燃料：再生燃料 － 替代燃料 Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel PN-EN ISO 21656:2021-08","test_object_zh":"废物 O)：代码 19 08 05、19 12 01、19 12 04、19 12 06、19 12 07、19 12 08、19 12 10；固体燃料：再生燃料 － 替代燃料 Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel"},{"_id":"6a5a55ef9af9f73f38250c1a","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, paliwa stałe: paliwo wtórne – paliwo alternatywne Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel","test_object_en":"Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel","methodology":"Zawartość tlenków Zakres: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Oxides content Range: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","methodology_en":"Oxide content Range: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) Oxides content Range: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość tlenków Zakres: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Oxides content Range: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","reference":"SO-4/ZLGIG/PB.05 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.24 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.05 ed. 1st of 01/08/2025 SO-4/ZLGIG/PB.24 ed. 1st of 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.05 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.24 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.05 ed. 1st of 01/08/2025 SO-4/ZLGIG/PB.24 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, paliwa stałe: paliwo wtórne – paliwo alternatywne Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel Zawartość tlenków Zakres: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Oxides content Range: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) SO-4/ZLGIG/PB.05 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.24 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.05 ed. 1st of 01/08/2025 SO-4/ZLGIG/PB.24 ed. 1st of 01/08/2025 Odpady O): kod 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, paliwa stale: paliwo wtorne – paliwo alternatywne Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel Zawartosc tlenkow Zakres: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja fali (WD-XRF) Oxides content Range: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) SO-4/ZLGIG/PB.05 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.24 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.05 ed. 1st of 01/08/2025 SO-4/ZLGIG/PB.24 ed. 1st of 01/08/2025","categories":["environment","petro"],"row_index":382,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel Oxide content Range: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) Oxides content Range: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) SO-4/ZLGIG/PB.05 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.24 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.05 ed. 1st of 01/08/2025 SO-4/ZLGIG/PB.24 ed. 1st of 01/08/2025","search_zh":"废物 O)：代码 19 08 05、19 12 01、19 12 04、19 12 06、19 12 07、19 12 08、19 12 10；固体燃料：再生燃料 － 替代燃料 Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel 氧化物含量 范围：SiO2 (1,20 – 89,16) %m/m、Al2O3 (0,12 – 43,72) %m/m、Fe2O3 (0,29 – 70,72) %m/m、CaO (0,18 – 70,81) %m/m、MgO (0,15 – 23,51) %m/m、Na2O (0,01 – 10,52) %m/m、K2O (0,05 – 3,78) %m/m、SO3 (0,30 – 72,02) %m/m、TiO2 (0,01 – 3,25) %m/m、P2O5 (0,04 – 14,66) %m/m X射线荧光法 SO-4/ZLGIG/PB.05 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.24 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.05 ed. 1st of 01/08/2025 SO-4/ZLGIG/PB.24 ed. 1st of 01/08/2025","test_object_zh":"废物 O)：代码 19 08 05、19 12 01、19 12 04、19 12 06、19 12 07、19 12 08、19 12 10；固体燃料：再生燃料 － 替代燃料 Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel","methodology_zh":"氧化物含量 范围：SiO2 (1,20 – 89,16) %m/m、Al2O3 (0,12 – 43,72) %m/m、Fe2O3 (0,29 – 70,72) %m/m、CaO (0,18 – 70,81) %m/m、MgO (0,15 – 23,51) %m/m、Na2O (0,01 – 10,52) %m/m、K2O (0,05 – 3,78) %m/m、SO3 (0,30 – 72,02) %m/m、TiO2 (0,01 – 3,25) %m/m、P2O5 (0,04 – 14,66) %m/m X射线荧光法"},{"_id":"6a5a55ef9af9f73f38250c1b","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, paliwa stałe: paliwo wtórne – paliwo alternatywne Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel","test_object_en":"Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel","methodology":"Zawartość rtęci Zakres: (0,01 – 20) mg/kg Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry method with amalgamation","methodology_en":"Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry with the amalgamation technique Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry method with amalgamation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość rtęci Zakres: (0,01 – 20) mg/kg Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry method with amalgamation","reference":"SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1st of 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, paliwa stałe: paliwo wtórne – paliwo alternatywne Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel Zawartość rtęci Zakres: (0,01 – 20) mg/kg Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry method with amalgamation SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1st of 01/08/2025 Odpady O): kod 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, paliwa stale: paliwo wtorne – paliwo alternatywne Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel Zawartosc rteci Zakres: (0,01 – 20) mg/kg Metoda absorpcyjnej spektrometrii atomowej z technika amalgamacji Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry method with amalgamation SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1st of 01/08/2025","categories":["environment","petro"],"row_index":383,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry with the amalgamation technique Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry method with amalgamation SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1st of 01/08/2025","search_zh":"废物 O)：代码 19 08 05、19 12 01、19 12 04、19 12 06、19 12 07、19 12 08、19 12 10；固体燃料：再生燃料 － 替代燃料 Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel 汞含量 范围：(0,01 – 20) mg/kg 汞齐化技术原子吸收光谱法 Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry method with amalgamation SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1st of 01/08/2025","test_object_zh":"废物 O)：代码 19 08 05、19 12 01、19 12 04、19 12 06、19 12 07、19 12 08、19 12 10；固体燃料：再生燃料 － 替代燃料 Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel","methodology_zh":"汞含量 范围：(0,01 – 20) mg/kg 汞齐化技术原子吸收光谱法 Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry method with amalgamation"},{"_id":"6a5a55ef9af9f73f38250c1c","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, paliwa stałe: paliwo wtórne – paliwo alternatywne Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel","test_object_en":"Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel","methodology":"Zawartość pierwiastków Zakres: As (1,0 – 1 000) mg/kg Ba (1,0 – 100 000) mg/kg Cd (1,0 – 1 000) mg/kg Co (1,0 – 10 000) mg/kg Cr (1,0 – 10 000) mg/kg Cu (1,0 – 10 000) mg/kg Mn (1,0 – 100 000) mg/kg Mo (1,0 – 10 000) mg/kg Ni (1,0 – 10 000) mg/kg Pb (1,0 – 50 000) mg/kg Sb (1,0 – 1 000) mg/kg Se (2,0 – 1 000) mg/kg Sn (1,0 – 1 000) mg/kg Zn (1,0 – 100 000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Elements content Range: As (1,0 – 1 000) mg/kg Ba (1,0 – 100 000) mg/kg Cd (1,0 – 1 000) mg/kg Co (1,0 – 10 000) mg/kg Cr (1,0 – 10 000) mg/kg Cu (1,0 – 10 000) mg/kg Mn (1,0 – 100 000) mg/kg Mo (1,0 – 10 000) mg/kg Ni (1,0 – 10 000) mg/kg Pb (1,0 – 50 000) mg/kg Sb (1,0 – 1 000) mg/kg Se (2,0 – 1 000) mg/kg Sn (1,0 – 1 000) mg/kg Zn (1,0 – 100 000) mg/kg Inductively coupled plasma optical emission spectrometry method (ICP-OES)","methodology_en":"Elements content Range: As (1,0 – 1 000) mg/kg Ba (1,0 – 100 000) mg/kg Cd (1,0 – 1 000) mg/kg Co (1,0 – 10 000) mg/kg Cr (1,0 – 10 000) mg/kg Cu (1,0 – 10 000) mg/kg Mn (1,0 – 100 000) mg/kg Mo (1,0 – 10 000) mg/kg Ni (1,0 – 10 000) mg/kg Pb (1,0 – 50 000) mg/kg Sb (1,0 – 1 000) mg/kg Se (2,0 – 1 000) mg/kg Sn (1,0 – 1 000) mg/kg Zn (1,0 – 100 000) mg/kg Inductively coupled plasma optical emission spectrometry method (ICP-OES)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość pierwiastków Zakres: As (1,0 – 1 000) mg/kg Ba (1,0 – 100 000) mg/kg Cd (1,0 – 1 000) mg/kg Co (1,0 – 10 000) mg/kg Cr (1,0 – 10 000) mg/kg Cu (1,0 – 10 000) mg/kg Mn (1,0 – 100 000) mg/kg Mo (1,0 – 10 000) mg/kg Ni (1,0 – 10 000) mg/kg Pb (1,0 – 50 000) mg/kg Sb (1,0 – 1 000) mg/kg Se (2,0 – 1 000) mg/kg Sn (1,0 – 1 000) mg/kg Zn (1,0 – 100 000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Elements content Range: As (1,0 – 1 000) mg/kg Ba (1,0 – 100 000) mg/kg Cd (1,0 – 1 000) mg/kg Co (1,0 – 10 000) mg/kg Cr (1,0 – 10 000) mg/kg Cu (1,0 – 10 000) mg/kg Mn (1,0 – 100 000) mg/kg Mo (1,0 – 10 000) mg/kg Ni (1,0 – 10 000) mg/kg Pb (1,0 – 50 000) mg/kg Sb (1,0 – 1 000) mg/kg Se (2,0 – 1 000) mg/kg Sn (1,0 – 1 000) mg/kg Zn (1,0 – 100 000) mg/kg Inductively coupled plasma optical emission spectrometry method (ICP-OES)","reference":"SO-4/ZLGIG/PB.11 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.11 ed. 1st of 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.11 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.11 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, paliwa stałe: paliwo wtórne – paliwo alternatywne Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel Zawartość pierwiastków Zakres: As (1,0 – 1 000) mg/kg Ba (1,0 – 100 000) mg/kg Cd (1,0 – 1 000) mg/kg Co (1,0 – 10 000) mg/kg Cr (1,0 – 10 000) mg/kg Cu (1,0 – 10 000) mg/kg Mn (1,0 – 100 000) mg/kg Mo (1,0 – 10 000) mg/kg Ni (1,0 – 10 000) mg/kg Pb (1,0 – 50 000) mg/kg Sb (1,0 – 1 000) mg/kg Se (2,0 – 1 000) mg/kg Sn (1,0 – 1 000) mg/kg Zn (1,0 – 100 000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Elements content Range: As (1,0 – 1 000) mg/kg Ba (1,0 – 100 000) mg/kg Cd (1,0 – 1 000) mg/kg Co (1,0 – 10 000) mg/kg Cr (1,0 – 10 000) mg/kg Cu (1,0 – 10 000) mg/kg Mn (1,0 – 100 000) mg/kg Mo (1,0 – 10 000) mg/kg Ni (1,0 – 10 000) mg/kg Pb (1,0 – 50 000) mg/kg Sb (1,0 – 1 000) mg/kg Se (2,0 – 1 000) mg/kg Sn (1,0 – 1 000) mg/kg Zn (1,0 – 100 000) mg/kg Inductively coupled plasma optical emission spectrometry method (ICP-OES) SO-4/ZLGIG/PB.11 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.11 ed. 1st of 01/08/2025 Odpady O): kod 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, paliwa stale: paliwo wtorne – paliwo alternatywne Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel Zawartosc pierwiastkow Zakres: As (1,0 – 1 000) mg/kg Ba (1,0 – 100 000) mg/kg Cd (1,0 – 1 000) mg/kg Co (1,0 – 10 000) mg/kg Cr (1,0 – 10 000) mg/kg Cu (1,0 – 10 000) mg/kg Mn (1,0 – 100 000) mg/kg Mo (1,0 – 10 000) mg/kg Ni (1,0 – 10 000) mg/kg Pb (1,0 – 50 000) mg/kg Sb (1,0 – 1 000) mg/kg Se (2,0 – 1 000) mg/kg Sn (1,0 – 1 000) mg/kg Zn (1,0 – 100 000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Elements content Range: As (1,0 – 1 000) mg/kg Ba (1,0 – 100 000) mg/kg Cd (1,0 – 1 000) mg/kg Co (1,0 – 10 000) mg/kg Cr (1,0 – 10 000) mg/kg Cu (1,0 – 10 000) mg/kg Mn (1,0 – 100 000) mg/kg Mo (1,0 – 10 000) mg/kg Ni (1,0 – 10 000) mg/kg Pb (1,0 – 50 000) mg/kg Sb (1,0 – 1 000) mg/kg Se (2,0 – 1 000) mg/kg Sn (1,0 – 1 000) mg/kg Zn (1,0 – 100 000) mg/kg Inductively coupled plasma optical emission spectrometry method (ICP-OES) SO-4/ZLGIG/PB.11 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.11 ed. 1st of 01/08/2025","categories":["environment","petro"],"row_index":384,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel Elements content Range: As (1,0 – 1 000) mg/kg Ba (1,0 – 100 000) mg/kg Cd (1,0 – 1 000) mg/kg Co (1,0 – 10 000) mg/kg Cr (1,0 – 10 000) mg/kg Cu (1,0 – 10 000) mg/kg Mn (1,0 – 100 000) mg/kg Mo (1,0 – 10 000) mg/kg Ni (1,0 – 10 000) mg/kg Pb (1,0 – 50 000) mg/kg Sb (1,0 – 1 000) mg/kg Se (2,0 – 1 000) mg/kg Sn (1,0 – 1 000) mg/kg Zn (1,0 – 100 000) mg/kg Inductively coupled plasma optical emission spectrometry method (ICP-OES) SO-4/ZLGIG/PB.11 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.11 ed. 1st of 01/08/2025","search_zh":"废物 O)：代码 19 08 05、19 12 01、19 12 04、19 12 06、19 12 07、19 12 08、19 12 10；固体燃料：再生燃料 － 替代燃料 Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel SO-4/ZLGIG/PB.11 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.11 ed. 1st of 01/08/2025","test_object_zh":"废物 O)：代码 19 08 05、19 12 01、19 12 04、19 12 06、19 12 07、19 12 08、19 12 10；固体燃料：再生燃料 － 替代燃料 Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel"},{"_id":"6a5a55ef9af9f73f38250c1d","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, paliwa stałe: paliwo wtórne – paliwo alternatywne Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel","test_object_en":"Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel","methodology":"Zawartość siarki całkowitej Zakres: (0,03 – 5,00) %m/m Metoda wysokotemperaturowego spalania z detekcją IR Total sulfur (TS) content Range: (0,03 – 5,00) %m/m High temp. combustion method with IR detection","methodology_en":"Total sulfur (TS) content Range: (0,03 – 5,00) %m/m High temp. combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej Zakres: (0,03 – 5,00) %m/m Metoda wysokotemperaturowego spalania z detekcją IR Total sulfur (TS) content Range: (0,03 – 5,00) %m/m High temp. combustion method with IR detection","reference":"PN-EN 15408:2011","norm_bases":["PN-EN 15408:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, paliwa stałe: paliwo wtórne – paliwo alternatywne Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel Zawartość siarki całkowitej Zakres: (0,03 – 5,00) %m/m Metoda wysokotemperaturowego spalania z detekcją IR Total sulfur (TS) content Range: (0,03 – 5,00) %m/m High temp. combustion method with IR detection PN-EN 15408:2011 Odpady O): kod 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, paliwa stale: paliwo wtorne – paliwo alternatywne Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel Zawartosc siarki calkowitej Zakres: (0,03 – 5,00) %m/m Metoda wysokotemperaturowego spalania z detekcja IR Total sulfur (TS) content Range: (0,03 – 5,00) %m/m High temp. combustion method with IR detection PN-EN 15408:2011","categories":["environment","petro"],"row_index":385,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel Total sulfur (TS) content Range: (0,03 – 5,00) %m/m High temp. combustion method with IR detection PN-EN 15408:2011","search_zh":"废物 O)：代码 19 08 05、19 12 01、19 12 04、19 12 06、19 12 07、19 12 08、19 12 10；固体燃料：再生燃料 － 替代燃料 Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel PN-EN 15408:2011","test_object_zh":"废物 O)：代码 19 08 05、19 12 01、19 12 04、19 12 06、19 12 07、19 12 08、19 12 10；固体燃料：再生燃料 － 替代燃料 Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel"},{"_id":"6a5a55ef9af9f73f38250c1e","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, paliwa stałe: paliwo wtórne – paliwo alternatywne Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel","test_object_en":"Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel","methodology":"Zawartość węgla całkowitego i wodoru całkowitego Zakres: C (20,0 – 95,0) %m/m H (0,11 – 20,00) %m/m Metoda wysokotemperaturowego spalania z detekcją IR Total carbon (TC), Total hydrogen (TH) content Range: C (20,0 – 95,0) %m/m H (0,11 – 20,00) %m/m High temp. combustion method with IR detection","methodology_en":"Total carbon (TC), Total hydrogen (TH) content Range: C (20,0 – 95,0) %m/m H (0,11 – 20,00) %m/m High temp. combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego i wodoru całkowitego Zakres: C (20,0 – 95,0) %m/m H (0,11 – 20,00) %m/m Metoda wysokotemperaturowego spalania z detekcją IR Total carbon (TC), Total hydrogen (TH) content Range: C (20,0 – 95,0) %m/m H (0,11 – 20,00) %m/m High temp. combustion method with IR detection","reference":"PN-EN ISO 21663:2021-06","norm_bases":["PN-EN ISO 21663:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, paliwa stałe: paliwo wtórne – paliwo alternatywne Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel Zawartość węgla całkowitego i wodoru całkowitego Zakres: C (20,0 – 95,0) %m/m H (0,11 – 20,00) %m/m Metoda wysokotemperaturowego spalania z detekcją IR Total carbon (TC), Total hydrogen (TH) content Range: C (20,0 – 95,0) %m/m H (0,11 – 20,00) %m/m High temp. combustion method with IR detection PN-EN ISO 21663:2021-06 Odpady O): kod 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, paliwa stale: paliwo wtorne – paliwo alternatywne Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel Zawartosc wegla calkowitego i wodoru calkowitego Zakres: C (20,0 – 95,0) %m/m H (0,11 – 20,00) %m/m Metoda wysokotemperaturowego spalania z detekcja IR Total carbon (TC), Total hydrogen (TH) content Range: C (20,0 – 95,0) %m/m H (0,11 – 20,00) %m/m High temp. combustion method with IR detection PN-EN ISO 21663:2021-06","categories":["environment","petro"],"row_index":386,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel Total carbon (TC), Total hydrogen (TH) content Range: C (20,0 – 95,0) %m/m H (0,11 – 20,00) %m/m High temp. combustion method with IR detection PN-EN ISO 21663:2021-06","search_zh":"废物 O)：代码 19 08 05、19 12 01、19 12 04、19 12 06、19 12 07、19 12 08、19 12 10；固体燃料：再生燃料 － 替代燃料 Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel PN-EN ISO 21663:2021-06","test_object_zh":"废物 O)：代码 19 08 05、19 12 01、19 12 04、19 12 06、19 12 07、19 12 08、19 12 10；固体燃料：再生燃料 － 替代燃料 Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel"},{"_id":"6a5a55ef9af9f73f38250c1f","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, paliwa stałe: paliwo wtórne – paliwo alternatywne Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel","test_object_en":"Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel","methodology":"Ciepło spalania Zakres: (6 000 – 46 390) kJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń) Gross calorific value Range: (6 000 – 46 390) kJ/kg Calorimetric method Net calorific value (from calculations)","methodology_en":"Gross calorific value Range: (6 000 – 46 390) kJ/kg Calorimetric method Net calorific value (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciepło spalania Zakres: (6 000 – 46 390) kJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń) Gross calorific value Range: (6 000 – 46 390) kJ/kg Calorimetric method Net calorific value (from calculations)","reference":"PN-EN ISO 21654:2021-12","norm_bases":["PN-EN ISO 21654:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, paliwa stałe: paliwo wtórne – paliwo alternatywne Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel Ciepło spalania Zakres: (6 000 – 46 390) kJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń) Gross calorific value Range: (6 000 – 46 390) kJ/kg Calorimetric method Net calorific value (from calculations) PN-EN ISO 21654:2021-12 Odpady O): kod 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, paliwa stale: paliwo wtorne – paliwo alternatywne Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel Cieplo spalania Zakres: (6 000 – 46 390) kJ/kg Metoda kalorymetryczna Wartosc opalowa (z obliczen) Gross calorific value Range: (6 000 – 46 390) kJ/kg Calorimetric method Net calorific value (from calculations) PN-EN ISO 21654:2021-12","categories":["environment","petro"],"row_index":387,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel Gross calorific value Range: (6 000 – 46 390) kJ/kg Calorimetric method Net calorific value (from calculations) PN-EN ISO 21654:2021-12","search_zh":"废物 O)：代码 19 08 05、19 12 01、19 12 04、19 12 06、19 12 07、19 12 08、19 12 10；固体燃料：再生燃料 － 替代燃料 Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel PN-EN ISO 21654:2021-12","test_object_zh":"废物 O)：代码 19 08 05、19 12 01、19 12 04、19 12 06、19 12 07、19 12 08、19 12 10；固体燃料：再生燃料 － 替代燃料 Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel"},{"_id":"6a5a55ef9af9f73f38250c20","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, paliwa stałe: paliwo wtórne – paliwo alternatywne Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel","test_object_en":"Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel","methodology":"Zawartość chloru Zakres: (0,07 – 7,00) %m/m Metoda miareczkowa Chlorine content Range: (0,07 – 7,00) %m/m Titrimetric method","methodology_en":"Chlorine content Range: (0,07 – 7,00) %m/m Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość chloru Zakres: (0,07 – 7,00) %m/m Metoda miareczkowa Chlorine content Range: (0,07 – 7,00) %m/m Titrimetric method","reference":"SO-4/ZLGIG/PB.17 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.17 ed. 1st of 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.17 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.17 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, paliwa stałe: paliwo wtórne – paliwo alternatywne Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel Zawartość chloru Zakres: (0,07 – 7,00) %m/m Metoda miareczkowa Chlorine content Range: (0,07 – 7,00) %m/m Titrimetric method SO-4/ZLGIG/PB.17 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.17 ed. 1st of 01/08/2025 Odpady O): kod 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, paliwa stale: paliwo wtorne – paliwo alternatywne Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel Zawartosc chloru Zakres: (0,07 – 7,00) %m/m Metoda miareczkowa Chlorine content Range: (0,07 – 7,00) %m/m Titrimetric method SO-4/ZLGIG/PB.17 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.17 ed. 1st of 01/08/2025","categories":["environment","petro"],"row_index":388,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel Chlorine content Range: (0,07 – 7,00) %m/m Titrimetric method SO-4/ZLGIG/PB.17 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.17 ed. 1st of 01/08/2025","search_zh":"废物 O)：代码 19 08 05、19 12 01、19 12 04、19 12 06、19 12 07、19 12 08、19 12 10；固体燃料：再生燃料 － 替代燃料 Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel SO-4/ZLGIG/PB.17 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.17 ed. 1st of 01/08/2025","test_object_zh":"废物 O)：代码 19 08 05、19 12 01、19 12 04、19 12 06、19 12 07、19 12 08、19 12 10；固体燃料：再生燃料 － 替代燃料 Solid wastesO): code 19 08 05, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 10, solid fuel: solid recovered fuels - refuse derived fuel"},{"_id":"6a5a55ef9af9f73f38250c21","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci pierwszego stopnia (wilgoci przemijającej) Zakres: (0,20 – 54,0) %m/m Metoda wagowa First-stage moisture Range: (0,20 – 54,0) %m/m Gravimetric method","methodology_en":"First-stage moisture (transient moisture) content Range: (0,20 – 54,0) %m/m Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci pierwszego stopnia (wilgoci przemijającej) Zakres: (0,20 – 54,0) %m/m Metoda wagowa First-stage moisture Range: (0,20 – 54,0) %m/m Gravimetric method","reference":"PN-ISO 589:2006","norm_bases":["PN-ISO 589:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Zawartość wilgoci pierwszego stopnia (wilgoci przemijającej) Zakres: (0,20 – 54,0) %m/m Metoda wagowa First-stage moisture Range: (0,20 – 54,0) %m/m Gravimetric method PN-ISO 589:2006 Paliwa stale: wegiel kamienny Solid fuels: hard coal Zawartosc wilgoci pierwszego stopnia (wilgoci przemijajacej) Zakres: (0,20 – 54,0) %m/m Metoda wagowa First-stage moisture Range: (0,20 – 54,0) %m/m Gravimetric method PN-ISO 589:2006","categories":["petro"],"row_index":389,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal First-stage moisture (transient moisture) content Range: (0,20 – 54,0) %m/m Gravimetric method PN-ISO 589:2006","search_zh":"固体燃料：烟煤 PN-ISO 589:2006","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ef9af9f73f38250c22","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci drugiego stopnia (wilgoci analitycznej) Zakres: (0,10 – 10,0) %m/m Metoda wagowa Second-stage moisture (analytical moisture) Range: (0,10 – 10,0) %m/m Gravimetric method","methodology_en":"Second-stage moisture (analytical moisture) Range: (0,10 – 10,0) %m/m Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci drugiego stopnia (wilgoci analitycznej) Zakres: (0,10 – 10,0) %m/m Metoda wagowa Second-stage moisture (analytical moisture) Range: (0,10 – 10,0) %m/m Gravimetric method","reference":"PN-ISO 589:2006","norm_bases":["PN-ISO 589:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Zawartość wilgoci drugiego stopnia (wilgoci analitycznej) Zakres: (0,10 – 10,0) %m/m Metoda wagowa Second-stage moisture (analytical moisture) Range: (0,10 – 10,0) %m/m Gravimetric method PN-ISO 589:2006 Paliwa stale: wegiel kamienny Solid fuels: hard coal Zawartosc wilgoci drugiego stopnia (wilgoci analitycznej) Zakres: (0,10 – 10,0) %m/m Metoda wagowa Second-stage moisture (analytical moisture) Range: (0,10 – 10,0) %m/m Gravimetric method PN-ISO 589:2006","categories":["petro"],"row_index":390,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Second-stage moisture (analytical moisture) Range: (0,10 – 10,0) %m/m Gravimetric method PN-ISO 589:2006","search_zh":"固体燃料：烟煤 PN-ISO 589:2006","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ef9af9f73f38250c23","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: Hard coal","test_object_en":"Solid fuels: Hard coal","methodology":"Zawartość wilgoci całkowitej (z obliczeń) Total moisture content (from calculations)","methodology_en":"Total moisture content (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej (z obliczeń) Total moisture content (from calculations)","reference":"PN-ISO 589:2006","norm_bases":["PN-ISO 589:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: Hard coal Zawartość wilgoci całkowitej (z obliczeń) Total moisture content (from calculations) PN-ISO 589:2006 Paliwa stale: wegiel kamienny Solid fuels: Hard coal Zawartosc wilgoci calkowitej (z obliczen) Total moisture content (from calculations) PN-ISO 589:2006","categories":["petro"],"row_index":391,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: Hard coal Total moisture content (from calculations) PN-ISO 589:2006","methodology_zh":"全水分含量（由计算得出） Total moisture content (from calculations)","search_zh":"固体燃料：烟煤 Solid fuels: Hard coal 全水分含量（由计算得出） Total moisture content (from calculations) PN-ISO 589:2006","test_object_zh":"固体燃料：烟煤 Solid fuels: Hard coal"},{"_id":"6a5a55ef9af9f73f38250c24","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: Hard coal","test_object_en":"Solid fuels: Hard coal","methodology":"Zawartość popiołu Zakres: (0,10 – 50,0) %m/m Metoda wagowa Ash content Range: (0,10 – 50,0) %m/m Gravimetric method","methodology_en":"Ash content Range: (0,10 – 50,0) %m/m Gravimetric method Ash content Range: (0,10 – 50,0) %m/m Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość popiołu Zakres: (0,10 – 50,0) %m/m Metoda wagowa Ash content Range: (0,10 – 50,0) %m/m Gravimetric method","reference":"PN-ISO 1171:2002","norm_bases":["PN-ISO 1171:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: Hard coal Zawartość popiołu Zakres: (0,10 – 50,0) %m/m Metoda wagowa Ash content Range: (0,10 – 50,0) %m/m Gravimetric method PN-ISO 1171:2002 Paliwa stale: wegiel kamienny Solid fuels: Hard coal Zawartosc popiolu Zakres: (0,10 – 50,0) %m/m Metoda wagowa Ash content Range: (0,10 – 50,0) %m/m Gravimetric method PN-ISO 1171:2002","categories":["petro"],"row_index":392,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: Hard coal Ash content Range: (0,10 – 50,0) %m/m Gravimetric method Ash content Range: (0,10 – 50,0) %m/m Gravimetric method PN-ISO 1171:2002","search_zh":"固体燃料：烟煤 Solid fuels: Hard coal PN-ISO 1171:2002","test_object_zh":"固体燃料：烟煤 Solid fuels: Hard coal"},{"_id":"6a5a55ef9af9f73f38250c25","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: Hard coal","test_object_en":"Solid fuels: Hard coal","methodology":"Zawartość strat prażenia (z obliczeń) Loss on ignition (from calculations)","methodology_en":"Loss on ignition (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość strat prażenia (z obliczeń) Loss on ignition (from calculations)","reference":"SO-4/ZLGIG/PB.03 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.03 ed. 1st of 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.03 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.03 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: Hard coal Zawartość strat prażenia (z obliczeń) Loss on ignition (from calculations) SO-4/ZLGIG/PB.03 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.03 ed. 1st of 01/08/2025 Paliwa stale: wegiel kamienny Solid fuels: Hard coal Zawartosc strat prazenia (z obliczen) Loss on ignition (from calculations) SO-4/ZLGIG/PB.03 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.03 ed. 1st of 01/08/2025","categories":["petro"],"row_index":393,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: Hard coal Loss on ignition (from calculations) SO-4/ZLGIG/PB.03 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.03 ed. 1st of 01/08/2025","search_zh":"固体燃料：烟煤 Solid fuels: Hard coal SO-4/ZLGIG/PB.03 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.03 ed. 1st of 01/08/2025","test_object_zh":"固体燃料：烟煤 Solid fuels: Hard coal"},{"_id":"6a5a55ef9af9f73f38250c26","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: Hard coal","test_object_en":"Solid fuels: Hard coal","methodology":"Zawartość węgla całkowitego i wodoru całkowitego Zakres: C (20,0 – 99,0) %m/m H (0,11 – 8,00) %m/m Metoda wysokotemperaturowego spalania z detekcją IR Total carbon (TC), Total hydrogen (TH) content Range: C (20,0 – 99,0) %m/m H (0,11 – 8,00) %m/m High temp. combustion method with IR detection","methodology_en":"Total carbon (TC), Total hydrogen (TH) content Range: C (20,0 – 99,0) %m/m H (0,11 – 8,00) %m/m High temp. combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego i wodoru całkowitego Zakres: C (20,0 – 99,0) %m/m H (0,11 – 8,00) %m/m Metoda wysokotemperaturowego spalania z detekcją IR Total carbon (TC), Total hydrogen (TH) content Range: C (20,0 – 99,0) %m/m H (0,11 – 8,00) %m/m High temp. combustion method with IR detection","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: Hard coal Zawartość węgla całkowitego i wodoru całkowitego Zakres: C (20,0 – 99,0) %m/m H (0,11 – 8,00) %m/m Metoda wysokotemperaturowego spalania z detekcją IR Total carbon (TC), Total hydrogen (TH) content Range: C (20,0 – 99,0) %m/m H (0,11 – 8,00) %m/m High temp. combustion method with IR detection PN-G-04571:1998 Paliwa stale: wegiel kamienny Solid fuels: Hard coal Zawartosc wegla calkowitego i wodoru calkowitego Zakres: C (20,0 – 99,0) %m/m H (0,11 – 8,00) %m/m Metoda wysokotemperaturowego spalania z detekcja IR Total carbon (TC), Total hydrogen (TH) content Range: C (20,0 – 99,0) %m/m H (0,11 – 8,00) %m/m High temp. combustion method with IR detection PN-G-04571:1998","categories":["petro"],"row_index":394,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: Hard coal Total carbon (TC), Total hydrogen (TH) content Range: C (20,0 – 99,0) %m/m H (0,11 – 8,00) %m/m High temp. combustion method with IR detection PN-G-04571:1998","search_zh":"固体燃料：烟煤 Solid fuels: Hard coal PN-G-04571:1998","test_object_zh":"固体燃料：烟煤 Solid fuels: Hard coal"},{"_id":"6a5a55ef9af9f73f38250c27","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: Hard coal","test_object_en":"Solid fuels: Hard coal","methodology":"Zawartość siarki całkowitej Zakres: (0,03 – 5,00) %m/m Metoda wysokotemperaturowego spalania z detekcją IR Total sulfur (TS) content Range: (0,03 – 5,00) %m/m m High temp. combustion method with IR detection","methodology_en":"Total sulfur (TS) content Range: (0,03 – 5,00) %m/m m High temp. combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej Zakres: (0,03 – 5,00) %m/m Metoda wysokotemperaturowego spalania z detekcją IR Total sulfur (TS) content Range: (0,03 – 5,00) %m/m m High temp. combustion method with IR detection","reference":"PN-G-04584:2001","norm_bases":["PN-G-04584:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: Hard coal Zawartość siarki całkowitej Zakres: (0,03 – 5,00) %m/m Metoda wysokotemperaturowego spalania z detekcją IR Total sulfur (TS) content Range: (0,03 – 5,00) %m/m m High temp. combustion method with IR detection PN-G-04584:2001 Paliwa stale: wegiel kamienny Solid fuels: Hard coal Zawartosc siarki calkowitej Zakres: (0,03 – 5,00) %m/m Metoda wysokotemperaturowego spalania z detekcja IR Total sulfur (TS) content Range: (0,03 – 5,00) %m/m m High temp. combustion method with IR detection PN-G-04584:2001","categories":["petro"],"row_index":395,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: Hard coal Total sulfur (TS) content Range: (0,03 – 5,00) %m/m m High temp. combustion method with IR detection PN-G-04584:2001","search_zh":"固体燃料：烟煤 Solid fuels: Hard coal PN-G-04584:2001","test_object_zh":"固体燃料：烟煤 Solid fuels: Hard coal"},{"_id":"6a5a55ef9af9f73f38250c28","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: Hard coal","test_object_en":"Solid fuels: Hard coal","methodology":"Zawartość azotu Kjeldahla Zakres: (0,15 – 4,50) %m/m Metoda miareczkowa Kjeldahl’s nitrogen content Range: (0,15 – 4,50) %m/m Titrimetric - potentiometric method","methodology_en":"Kjeldahl’s nitrogen content Range: (0,15 – 4,50) %m/m Titrimetric - potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość azotu Kjeldahla Zakres: (0,15 – 4,50) %m/m Metoda miareczkowa Kjeldahl’s nitrogen content Range: (0,15 – 4,50) %m/m Titrimetric - potentiometric method","reference":"SO-4/ZLGIG/PB.14 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.14 ed. 1st of 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.14 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.14 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: Hard coal Zawartość azotu Kjeldahla Zakres: (0,15 – 4,50) %m/m Metoda miareczkowa Kjeldahl’s nitrogen content Range: (0,15 – 4,50) %m/m Titrimetric - potentiometric method SO-4/ZLGIG/PB.14 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.14 ed. 1st of 01/08/2025 Paliwa stale: wegiel kamienny Solid fuels: Hard coal Zawartosc azotu Kjeldahla Zakres: (0,15 – 4,50) %m/m Metoda miareczkowa Kjeldahl’s nitrogen content Range: (0,15 – 4,50) %m/m Titrimetric - potentiometric method SO-4/ZLGIG/PB.14 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.14 ed. 1st of 01/08/2025","categories":["petro"],"row_index":396,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: Hard coal Kjeldahl’s nitrogen content Range: (0,15 – 4,50) %m/m Titrimetric - potentiometric method SO-4/ZLGIG/PB.14 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.14 ed. 1st of 01/08/2025","search_zh":"固体燃料：烟煤 Solid fuels: Hard coal SO-4/ZLGIG/PB.14 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.14 ed. 1st of 01/08/2025","test_object_zh":"固体燃料：烟煤 Solid fuels: Hard coal"},{"_id":"6a5a55ef9af9f73f38250c29","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: Hard coal","test_object_en":"Solid fuels: Hard coal","methodology":"Ciepło spalania Zakres: (8800 – 40000) kJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń) Gross calorific value Range: (8800 – 40000) kJ/kg Calorimetric method Net calorific value (from calculations)","methodology_en":"Gross calorific value Range: (8800 – 40000) kJ/kg Calorimetric method Net calorific value (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciepło spalania Zakres: (8800 – 40000) kJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń) Gross calorific value Range: (8800 – 40000) kJ/kg Calorimetric method Net calorific value (from calculations)","reference":"PN-ISO 1928:2020-05","norm_bases":["PN-ISO 1928:2020-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: Hard coal Ciepło spalania Zakres: (8800 – 40000) kJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń) Gross calorific value Range: (8800 – 40000) kJ/kg Calorimetric method Net calorific value (from calculations) PN-ISO 1928:2020-05 Paliwa stale: wegiel kamienny Solid fuels: Hard coal Cieplo spalania Zakres: (8800 – 40000) kJ/kg Metoda kalorymetryczna Wartosc opalowa (z obliczen) Gross calorific value Range: (8800 – 40000) kJ/kg Calorimetric method Net calorific value (from calculations) PN-ISO 1928:2020-05","categories":["petro"],"row_index":397,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: Hard coal Gross calorific value Range: (8800 – 40000) kJ/kg Calorimetric method Net calorific value (from calculations) PN-ISO 1928:2020-05","search_zh":"固体燃料：烟煤 Solid fuels: Hard coal PN-ISO 1928:2020-05","test_object_zh":"固体燃料：烟煤 Solid fuels: Hard coal"},{"_id":"6a5a55ef9af9f73f38250c2a","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość chloru Zakres: (0,07 – 2,00) %m/m Metoda miareczkowa Chlorine content Range: (0,07 – 2,00) %m/m Titrimetric method","methodology_en":"Chlorine content Range: (0,07 – 2,00) %m/m Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość chloru Zakres: (0,07 – 2,00) %m/m Metoda miareczkowa Chlorine content Range: (0,07 – 2,00) %m/m Titrimetric method","reference":"PN-ISO 587:2000","norm_bases":["PN-ISO 587:2000"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Zawartość chloru Zakres: (0,07 – 2,00) %m/m Metoda miareczkowa Chlorine content Range: (0,07 – 2,00) %m/m Titrimetric method PN-ISO 587:2000 Paliwa stale: wegiel kamienny Solid fuels: hard coal Zawartosc chloru Zakres: (0,07 – 2,00) %m/m Metoda miareczkowa Chlorine content Range: (0,07 – 2,00) %m/m Titrimetric method PN-ISO 587:2000","categories":["petro"],"row_index":398,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Chlorine content Range: (0,07 – 2,00) %m/m Titrimetric method PN-ISO 587:2000","search_zh":"固体燃料：烟煤 PN-ISO 587:2000","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ef9af9f73f38250c2b","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość rtęci Zakres: (0,01 – 20) mg/kg Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry method with amalgamation","methodology_en":"Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry with the amalgamation technique Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry method with amalgamation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość rtęci Zakres: (0,01 – 20) mg/kg Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry method with amalgamation","reference":"SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1st of 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Zawartość rtęci Zakres: (0,01 – 20) mg/kg Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry method with amalgamation SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1st of 01/08/2025 Paliwa stale: wegiel kamienny Solid fuels: hard coal Zawartosc rteci Zakres: (0,01 – 20) mg/kg Metoda absorpcyjnej spektrometrii atomowej z technika amalgamacji Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry method with amalgamation SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1st of 01/08/2025","categories":["petro"],"row_index":399,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry with the amalgamation technique Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry method with amalgamation SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1st of 01/08/2025","search_zh":"固体燃料：烟煤 汞含量 范围：(0,01 – 20) mg/kg 汞齐化技术原子吸收光谱法 Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry method with amalgamation SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1st of 01/08/2025","test_object_zh":"固体燃料：烟煤","methodology_zh":"汞含量 范围：(0,01 – 20) mg/kg 汞齐化技术原子吸收光谱法 Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry method with amalgamation"},{"_id":"6a5a55ef9af9f73f38250c2c","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość pierwiastków Zakres: As (1,0 – 500) mg/kg Ba (1,0 – 50000) mg/kg Cd (1,0 – 500) mg/kg Co (1,0 – 1000) mg/kg Cr (1,0 – 1000) mg/kg Cu (1,0 – 1000) mg/kg Mn (1,0 – 30000) mg/kg Mo (1,0 – 1000) mg/kg Ni (1,0 – 1000) mg/kg Pb (1,0 – 5000) mg/kg Sb (1,0 – 500) mg/kg Se (2,0 – 500) mg/kg Sn (1,0 – 500) mg/kg Zn (1,0 – 50000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Elements content Range: As (1,0 – 500) mg/kg Ba (1,0 – 50000) mg/kg Cd (1,0 – 500) mg/kg Co (1,0 – 1000) mg/kg Cr (1,0 – 1000) mg/kg Cu (1,0 – 1000) mg/kg Mn (1,0 – 30000) mg/kg Mo (1,0 – 1000) mg/kg Ni (1,0 – 1000) mg/kg Pb (1,0 – 5000) mg/kg Sb (1,0 – 500) mg/kg Se (2,0 – 500) mg/kg Sn (1,0 – 500) mg/kg Zn (1,0 – 50000) mg/kg Inductively coupled plasma optical emission spectrometry method (ICP-OES)","methodology_en":"Elements content Range: As (1,0 – 500) mg/kg Ba (1,0 – 50000) mg/kg Cd (1,0 – 500) mg/kg Co (1,0 – 1000) mg/kg Cr (1,0 – 1000) mg/kg Cu (1,0 – 1000) mg/kg Mn (1,0 – 30000) mg/kg Mo (1,0 – 1000) mg/kg Ni (1,0 – 1000) mg/kg Pb (1,0 – 5000) mg/kg Sb (1,0 – 500) mg/kg Se (2,0 – 500) mg/kg Sn (1,0 – 500) mg/kg Zn (1,0 – 50000) mg/kg Inductively coupled plasma optical emission spectrometry method (ICP-OES)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość pierwiastków Zakres: As (1,0 – 500) mg/kg Ba (1,0 – 50000) mg/kg Cd (1,0 – 500) mg/kg Co (1,0 – 1000) mg/kg Cr (1,0 – 1000) mg/kg Cu (1,0 – 1000) mg/kg Mn (1,0 – 30000) mg/kg Mo (1,0 – 1000) mg/kg Ni (1,0 – 1000) mg/kg Pb (1,0 – 5000) mg/kg Sb (1,0 – 500) mg/kg Se (2,0 – 500) mg/kg Sn (1,0 – 500) mg/kg Zn (1,0 – 50000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Elements content Range: As (1,0 – 500) mg/kg Ba (1,0 – 50000) mg/kg Cd (1,0 – 500) mg/kg Co (1,0 – 1000) mg/kg Cr (1,0 – 1000) mg/kg Cu (1,0 – 1000) mg/kg Mn (1,0 – 30000) mg/kg Mo (1,0 – 1000) mg/kg Ni (1,0 – 1000) mg/kg Pb (1,0 – 5000) mg/kg Sb (1,0 – 500) mg/kg Se (2,0 – 500) mg/kg Sn (1,0 – 500) mg/kg Zn (1,0 – 50000) mg/kg Inductively coupled plasma optical emission spectrometry method (ICP-OES)","reference":"SO-4/ZLGIG/PB.11 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.11 ed. 1st of 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.11 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.11 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Zawartość pierwiastków Zakres: As (1,0 – 500) mg/kg Ba (1,0 – 50000) mg/kg Cd (1,0 – 500) mg/kg Co (1,0 – 1000) mg/kg Cr (1,0 – 1000) mg/kg Cu (1,0 – 1000) mg/kg Mn (1,0 – 30000) mg/kg Mo (1,0 – 1000) mg/kg Ni (1,0 – 1000) mg/kg Pb (1,0 – 5000) mg/kg Sb (1,0 – 500) mg/kg Se (2,0 – 500) mg/kg Sn (1,0 – 500) mg/kg Zn (1,0 – 50000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Elements content Range: As (1,0 – 500) mg/kg Ba (1,0 – 50000) mg/kg Cd (1,0 – 500) mg/kg Co (1,0 – 1000) mg/kg Cr (1,0 – 1000) mg/kg Cu (1,0 – 1000) mg/kg Mn (1,0 – 30000) mg/kg Mo (1,0 – 1000) mg/kg Ni (1,0 – 1000) mg/kg Pb (1,0 – 5000) mg/kg Sb (1,0 – 500) mg/kg Se (2,0 – 500) mg/kg Sn (1,0 – 500) mg/kg Zn (1,0 – 50000) mg/kg Inductively coupled plasma optical emission spectrometry method (ICP-OES) SO-4/ZLGIG/PB.11 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.11 ed. 1st of 01/08/2025 Paliwa stale: wegiel kamienny Solid fuels: hard coal Zawartosc pierwiastkow Zakres: As (1,0 – 500) mg/kg Ba (1,0 – 50000) mg/kg Cd (1,0 – 500) mg/kg Co (1,0 – 1000) mg/kg Cr (1,0 – 1000) mg/kg Cu (1,0 – 1000) mg/kg Mn (1,0 – 30000) mg/kg Mo (1,0 – 1000) mg/kg Ni (1,0 – 1000) mg/kg Pb (1,0 – 5000) mg/kg Sb (1,0 – 500) mg/kg Se (2,0 – 500) mg/kg Sn (1,0 – 500) mg/kg Zn (1,0 – 50000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Elements content Range: As (1,0 – 500) mg/kg Ba (1,0 – 50000) mg/kg Cd (1,0 – 500) mg/kg Co (1,0 – 1000) mg/kg Cr (1,0 – 1000) mg/kg Cu (1,0 – 1000) mg/kg Mn (1,0 – 30000) mg/kg Mo (1,0 – 1000) mg/kg Ni (1,0 – 1000) mg/kg Pb (1,0 – 5000) mg/kg Sb (1,0 – 500) mg/kg Se (2,0 – 500) mg/kg Sn (1,0 – 500) mg/kg Zn (1,0 – 50000) mg/kg Inductively coupled plasma optical emission spectrometry method (ICP-OES) SO-4/ZLGIG/PB.11 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.11 ed. 1st of 01/08/2025","categories":["petro","environment"],"row_index":400,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Elements content Range: As (1,0 – 500) mg/kg Ba (1,0 – 50000) mg/kg Cd (1,0 – 500) mg/kg Co (1,0 – 1000) mg/kg Cr (1,0 – 1000) mg/kg Cu (1,0 – 1000) mg/kg Mn (1,0 – 30000) mg/kg Mo (1,0 – 1000) mg/kg Ni (1,0 – 1000) mg/kg Pb (1,0 – 5000) mg/kg Sb (1,0 – 500) mg/kg Se (2,0 – 500) mg/kg Sn (1,0 – 500) mg/kg Zn (1,0 – 50000) mg/kg Inductively coupled plasma optical emission spectrometry method (ICP-OES) SO-4/ZLGIG/PB.11 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.11 ed. 1st of 01/08/2025","search_zh":"固体燃料：烟煤 SO-4/ZLGIG/PB.11 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.11 ed. 1st of 01/08/2025","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ef9af9f73f38250c2d","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość tlenków Zakres: SiO (3,36 – 69,06) %m/m 2 Al O (2,18 – 43,23) %m/m 2 3 Fe O (1,16 – 50,20) %m/m 2 3 CaO (0,40 – 34,58) %m/m MgO (0,80 – 17,84) %m/m Na O (0,07 – 5,75) %m/m 2 K O (0,16 – 3,88) %m/m 2 SO (0,27 – 33,50) %m/m 3 TiO (0,10 – 3,25) %m/m 2 P O (0,02 – 8,84) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Oxides content Range: SiO (3,36 – 69,06) %m/m 2 Al O (2,18 – 43,23) %m/m 2 3 Fe O (1,16 – 50,20) %m/m 2 3 CaO (0,40 – 34,58) %m/m MgO (0,80 – 17,84) %m/m Na O (0,07 – 5,75) %m/m 2 K O (0,16 – 3,88) %m/m 2 SO (0,27 – 33,50) %m/m 3 TiO (0,10 – 3,25) %m/m 2 P O (0,02 – 8,84) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD- XRF)","methodology_en":"Oxides content Range: SiO (3,36 – 69,06) %m/m 2 Al O (2,18 – 43,23) %m/m 2 3 Fe O (1,16 – 50,20) %m/m 2 3 CaO (0,40 – 34,58) %m/m MgO (0,80 – 17,84) %m/m Na O (0,07 – 5,75) %m/m 2 K O (0,16 – 3,88) %m/m 2 SO (0,27 – 33,50) %m/m 3 TiO (0,10 – 3,25) %m/m 2 P O (0,02 – 8,84) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD- XRF)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość tlenków Zakres: SiO (3,36 – 69,06) %m/m 2 Al O (2,18 – 43,23) %m/m 2 3 Fe O (1,16 – 50,20) %m/m 2 3 CaO (0,40 – 34,58) %m/m MgO (0,80 – 17,84) %m/m Na O (0,07 – 5,75) %m/m 2 K O (0,16 – 3,88) %m/m 2 SO (0,27 – 33,50) %m/m 3 TiO (0,10 – 3,25) %m/m 2 P O (0,02 – 8,84) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Oxides content Range: SiO (3,36 – 69,06) %m/m 2 Al O (2,18 – 43,23) %m/m 2 3 Fe O (1,16 – 50,20) %m/m 2 3 CaO (0,40 – 34,58) %m/m MgO (0,80 – 17,84) %m/m Na O (0,07 – 5,75) %m/m 2 K O (0,16 – 3,88) %m/m 2 SO (0,27 – 33,50) %m/m 3 TiO (0,10 – 3,25) %m/m 2 P O (0,02 – 8,84) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD- XRF)","reference":"ISO 13605:2018 (E)","norm_bases":["ISO 13605:2018 (E)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Zawartość tlenków Zakres: SiO (3,36 – 69,06) %m/m 2 Al O (2,18 – 43,23) %m/m 2 3 Fe O (1,16 – 50,20) %m/m 2 3 CaO (0,40 – 34,58) %m/m MgO (0,80 – 17,84) %m/m Na O (0,07 – 5,75) %m/m 2 K O (0,16 – 3,88) %m/m 2 SO (0,27 – 33,50) %m/m 3 TiO (0,10 – 3,25) %m/m 2 P O (0,02 – 8,84) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Oxides content Range: SiO (3,36 – 69,06) %m/m 2 Al O (2,18 – 43,23) %m/m 2 3 Fe O (1,16 – 50,20) %m/m 2 3 CaO (0,40 – 34,58) %m/m MgO (0,80 – 17,84) %m/m Na O (0,07 – 5,75) %m/m 2 K O (0,16 – 3,88) %m/m 2 SO (0,27 – 33,50) %m/m 3 TiO (0,10 – 3,25) %m/m 2 P O (0,02 – 8,84) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD- XRF) ISO 13605:2018 (E) Paliwa stale: wegiel kamienny Solid fuels: hard coal Zawartosc tlenkow Zakres: SiO (3,36 – 69,06) %m/m 2 Al O (2,18 – 43,23) %m/m 2 3 Fe O (1,16 – 50,20) %m/m 2 3 CaO (0,40 – 34,58) %m/m MgO (0,80 – 17,84) %m/m Na O (0,07 – 5,75) %m/m 2 K O (0,16 – 3,88) %m/m 2 SO (0,27 – 33,50) %m/m 3 TiO (0,10 – 3,25) %m/m 2 P O (0,02 – 8,84) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja fali (WD-XRF) Oxides content Range: SiO (3,36 – 69,06) %m/m 2 Al O (2,18 – 43,23) %m/m 2 3 Fe O (1,16 – 50,20) %m/m 2 3 CaO (0,40 – 34,58) %m/m MgO (0,80 – 17,84) %m/m Na O (0,07 – 5,75) %m/m 2 K O (0,16 – 3,88) %m/m 2 SO (0,27 – 33,50) %m/m 3 TiO (0,10 – 3,25) %m/m 2 P O (0,02 – 8,84) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD- XRF) ISO 13605:2018 (E)","categories":["petro"],"row_index":401,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Oxides content Range: SiO (3,36 – 69,06) %m/m 2 Al O (2,18 – 43,23) %m/m 2 3 Fe O (1,16 – 50,20) %m/m 2 3 CaO (0,40 – 34,58) %m/m MgO (0,80 – 17,84) %m/m Na O (0,07 – 5,75) %m/m 2 K O (0,16 – 3,88) %m/m 2 SO (0,27 – 33,50) %m/m 3 TiO (0,10 – 3,25) %m/m 2 P O (0,02 – 8,84) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD- XRF) ISO 13605:2018 (E)","search_zh":"固体燃料：烟煤 ISO 13605:2018 (E)","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ef9af9f73f38250c2e","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość fluoru Zakres: (0,002 – 0,15) % m/m Metoda potencjometryczna Fluorine content Range: (0.002 – 0.15) % m/m Potentiometric method","methodology_en":"Fluorine content Range: (0.002 – 0.15) % m/m Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość fluoru Zakres: (0,002 – 0,15) % m/m Metoda potencjometryczna Fluorine content Range: (0.002 – 0.15) % m/m Potentiometric method","reference":"PN-82/G-04543","norm_bases":["PN-82/G-04543"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Zawartość fluoru Zakres: (0,002 – 0,15) % m/m Metoda potencjometryczna Fluorine content Range: (0.002 – 0.15) % m/m Potentiometric method PN-82/G-04543 Paliwa stale: wegiel kamienny Solid fuels: hard coal Zawartosc fluoru Zakres: (0,002 – 0,15) % m/m Metoda potencjometryczna Fluorine content Range: (0.002 – 0.15) % m/m Potentiometric method PN-82/G-04543","categories":["petro"],"row_index":402,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Fluorine content Range: (0.002 – 0.15) % m/m Potentiometric method PN-82/G-04543","search_zh":"固体燃料：烟煤 PN-82/G-04543","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ef9af9f73f38250c2f","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość części lotnych Zakres: (1,00 – 40,00) % m/m Metoda wagowa Content of volatile matter Range: (1,00 – 40,00) % m/m Gravimetric method","methodology_en":"Content of volatile matter Range: (1,00 – 40,00) % m/m Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość części lotnych Zakres: (1,00 – 40,00) % m/m Metoda wagowa Content of volatile matter Range: (1,00 – 40,00) % m/m Gravimetric method","reference":"PN-G-04516:1998","norm_bases":["PN-G-04516:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Zawartość części lotnych Zakres: (1,00 – 40,00) % m/m Metoda wagowa Content of volatile matter Range: (1,00 – 40,00) % m/m Gravimetric method PN-G-04516:1998 Paliwa stale: wegiel kamienny Solid fuels: hard coal Zawartosc czesci lotnych Zakres: (1,00 – 40,00) % m/m Metoda wagowa Content of volatile matter Range: (1,00 – 40,00) % m/m Gravimetric method PN-G-04516:1998","categories":["petro"],"row_index":403,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Content of volatile matter Range: (1,00 – 40,00) % m/m Gravimetric method PN-G-04516:1998","search_zh":"固体燃料：烟煤 PN-G-04516:1998","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ef9af9f73f38250c30","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość bromu Zakres: (1 – 40) mg/kg Metodą fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Bromine content Range: (1 – 40) mg/kg Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","methodology_en":"Bromine content Range: (1 – 40) mg/kg Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość bromu Zakres: (1 – 40) mg/kg Metodą fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Bromine content Range: (1 – 40) mg/kg Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","reference":"SO-4/ZLGIG/PB.25 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.25 ed. 1st 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.25 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.25 ed. 1st 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Zawartość bromu Zakres: (1 – 40) mg/kg Metodą fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Bromine content Range: (1 – 40) mg/kg Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) SO-4/ZLGIG/PB.25 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.25 ed. 1st 01/08/2025 Paliwa stale: wegiel kamienny Solid fuels: hard coal Zawartosc bromu Zakres: (1 – 40) mg/kg Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja fali (WD-XRF) Bromine content Range: (1 – 40) mg/kg Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) SO-4/ZLGIG/PB.25 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.25 ed. 1st 01/08/2025","categories":["petro"],"row_index":404,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Bromine content Range: (1 – 40) mg/kg Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) SO-4/ZLGIG/PB.25 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.25 ed. 1st 01/08/2025","search_zh":"固体燃料：烟煤 SO-4/ZLGIG/PB.25 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.25 ed. 1st 01/08/2025","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ef9af9f73f38250c31","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod 01 01 02, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste","test_object_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste","methodology":"Zawartość tlenków Zakres: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Oxides content Range: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","methodology_en":"Oxide content Range: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) Oxides content Range: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość tlenków Zakres: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Oxides content Range: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","reference":"PN-EN 15309:2010","norm_bases":["PN-EN 15309:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 01 01 02, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Zawartość tlenków Zakres: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Oxides content Range: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) PN-EN 15309:2010 Odpady O): kod 01 01 02, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Zuzle, popioly paleniskowe i pyly z kotlow, popioly lotne z wegla, stale odpady z wapniowych metod odsiarczania gazow odlotowych, piaski ze zloz fluidalnych, mieszaniny popiolow lotnych i odpadow stalych z wapniowych metod odsiarczania gazow odlotowych, mieszanki popiolowo-zuzlowe z mokrego odprowadzania odpadow paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Zawartosc tlenkow Zakres: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja fali (WD-XRF) Oxides content Range: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) PN-EN 15309:2010","categories":["environment"],"row_index":405,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Oxide content Range: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) Oxides content Range: SiO (1,20 – 89,16) %m/m 2 Al O (0,12 – 43,72) %m/m 2 3 Fe O (0,29 – 70,72) %m/m 2 3 CaO (0,18 – 70,81) %m/m MgO (0,15 – 23,51) %m/m Na O (0,01 – 10,52) %m/m 2 K O (0,05 – 3,78) %m/m 2 SO (0,30 – 72,02) %m/m 3 TiO (0,01 – 3,25) %m/m 2 P O (0,04 – 14,66) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) PN-EN 15309:2010","methodology_zh":"氧化物含量 范围：SiO2 (1,20 – 89,16) %m/m、Al2O3 (0,12 – 43,72) %m/m、Fe2O3 (0,29 – 70,72) %m/m、CaO (0,18 – 70,81) %m/m、MgO (0,15 – 23,51) %m/m、Na2O (0,01 – 10,52) %m/m、K2O (0,05 – 3,78) %m/m、SO3 (0,30 – 72,02) %m/m、TiO2 (0,01 – 3,25) %m/m、P2O5 (0,04 – 14,66) %m/m X射线荧光法","search_zh":"氧化物含量 范围：SiO2 (1,20 – 89,16) %m/m、Al2O3 (0,12 – 43,72) %m/m、Fe2O3 (0,29 – 70,72) %m/m、CaO (0,18 – 70,81) %m/m、MgO (0,15 – 23,51) %m/m、Na2O (0,01 – 10,52) %m/m、K2O (0,05 – 3,78) %m/m、SO3 (0,30 – 72,02) %m/m、TiO2 (0,01 – 3,25) %m/m、P2O5 (0,04 – 14,66) %m/m X射线荧光法 PN-EN 15309:2010"},{"_id":"6a5a55ef9af9f73f38250c32","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod 01 01 02, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste","test_object_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste","methodology":"Zawartość tlenków Zakres: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Oxides content Range: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","methodology_en":"Oxides content Range: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) Oxides content Range: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość tlenków Zakres: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Oxides content Range: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","reference":"PN-EN 15309:2010","norm_bases":["PN-EN 15309:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 01 01 02, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Zawartość tlenków Zakres: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Oxides content Range: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) PN-EN 15309:2010 Odpady O): kod 01 01 02, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Zuzle, popioly paleniskowe i pyly z kotlow, popioly lotne z wegla, stale odpady z wapniowych metod odsiarczania gazow odlotowych, piaski ze zloz fluidalnych, mieszaniny popiolow lotnych i odpadow stalych z wapniowych metod odsiarczania gazow odlotowych, mieszanki popiolowo-zuzlowe z mokrego odprowadzania odpadow paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Zawartosc tlenkow Zakres: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja fali (WD-XRF) Oxides content Range: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) PN-EN 15309:2010","categories":["environment"],"row_index":406,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Oxides content Range: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) Oxides content Range: SiO (0,01 – 97,35) %m/m 2 Al O (0,01 – 95,50) %m/m 2 3 Fe O (0,01 – 95,75) %m/m 2 3 CaO (0,01 – 99,24) %m/m MgO (0,01 – 82,25) %m/m Na O (0,01 – 39,28) %m/m 2 K O (0,01 – 48,93) %m/m 2 SO (0,02 – 51,40) %m/m 3 TiO (0,01 – 39,79) %m/m 2 P O (0,01 – 44,84) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) PN-EN 15309:2010"},{"_id":"6a5a55ef9af9f73f38250c33","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod 01 03 80, 01 03 81 Solid wastesO): code 01 03 80, 01 03 81","test_object_en":"Solid wastesO): code 01 03 80, 01 03 81","methodology":"Zawartość pierwiastków Zakres: As (2,0 – 2800) mg/kg Ba (2,0 – 2200) mg/kg Cd (1,0 – 10000) mg/kg Co (1,0 – 10000) mg/kg Cr (1,0 – 10000) mg/kg Cu (1,0 – 10000) mg/kg Mn (1,0 – 11000) mg/kg Mo (1,0 – 2000) mg/kg Ni (1,0 – 10000) mg/kg Pb (10,0 – 17000) mg/kg Sb (2,0 – 2000) mg/kg Se (2,0 – 2000) mg/kg Sn (1,0 – 2000) mg/kg Zn (1,0 – 21200) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Elements content Range: As (2,0 – 2800) mg/kg Ba (2,0 – 2200) mg/kg Cd (1,0 – 10000) mg/kg Co (1,0 – 10000) mg/kg Cr (1,0 – 10000) mg/kg Cu (1,0 – 10000) mg/kg Mn (1,0 – 11000) mg/kg Mo (1,0 – 2000) mg/kg Ni (1,0 – 10000) mg/kg Pb (10,0 – 17000) mg/kg Sb (2,0 – 2000) mg/kg Se (2,0 – 2000) mg/kg Sn (1,0 – 2000) mg/kg Zn (1,0 – 21200) mg/kg Inductively coupled plasma optical emission spectrometry method (ICP- OES)","methodology_en":"Elements content Range: As (2,0 – 2800) mg/kg Ba (2,0 – 2200) mg/kg Cd (1,0 – 10000) mg/kg Co (1,0 – 10000) mg/kg Cr (1,0 – 10000) mg/kg Cu (1,0 – 10000) mg/kg Mn (1,0 – 11000) mg/kg Mo (1,0 – 2000) mg/kg Ni (1,0 – 10000) mg/kg Pb (10,0 – 17000) mg/kg Sb (2,0 – 2000) mg/kg Se (2,0 – 2000) mg/kg Sn (1,0 – 2000) mg/kg Zn (1,0 – 21200) mg/kg Inductively coupled plasma optical emission spectrometry method (ICP- OES)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość pierwiastków Zakres: As (2,0 – 2800) mg/kg Ba (2,0 – 2200) mg/kg Cd (1,0 – 10000) mg/kg Co (1,0 – 10000) mg/kg Cr (1,0 – 10000) mg/kg Cu (1,0 – 10000) mg/kg Mn (1,0 – 11000) mg/kg Mo (1,0 – 2000) mg/kg Ni (1,0 – 10000) mg/kg Pb (10,0 – 17000) mg/kg Sb (2,0 – 2000) mg/kg Se (2,0 – 2000) mg/kg Sn (1,0 – 2000) mg/kg Zn (1,0 – 21200) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Elements content Range: As (2,0 – 2800) mg/kg Ba (2,0 – 2200) mg/kg Cd (1,0 – 10000) mg/kg Co (1,0 – 10000) mg/kg Cr (1,0 – 10000) mg/kg Cu (1,0 – 10000) mg/kg Mn (1,0 – 11000) mg/kg Mo (1,0 – 2000) mg/kg Ni (1,0 – 10000) mg/kg Pb (10,0 – 17000) mg/kg Sb (2,0 – 2000) mg/kg Se (2,0 – 2000) mg/kg Sn (1,0 – 2000) mg/kg Zn (1,0 – 21200) mg/kg Inductively coupled plasma optical emission spectrometry method (ICP- OES)","reference":"PN-EN 13657:2006 PN-EN ISO 11885:2009","norm_bases":["PN-EN 13657:2006 PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 01 03 80, 01 03 81 Solid wastesO): code 01 03 80, 01 03 81 Zawartość pierwiastków Zakres: As (2,0 – 2800) mg/kg Ba (2,0 – 2200) mg/kg Cd (1,0 – 10000) mg/kg Co (1,0 – 10000) mg/kg Cr (1,0 – 10000) mg/kg Cu (1,0 – 10000) mg/kg Mn (1,0 – 11000) mg/kg Mo (1,0 – 2000) mg/kg Ni (1,0 – 10000) mg/kg Pb (10,0 – 17000) mg/kg Sb (2,0 – 2000) mg/kg Se (2,0 – 2000) mg/kg Sn (1,0 – 2000) mg/kg Zn (1,0 – 21200) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Elements content Range: As (2,0 – 2800) mg/kg Ba (2,0 – 2200) mg/kg Cd (1,0 – 10000) mg/kg Co (1,0 – 10000) mg/kg Cr (1,0 – 10000) mg/kg Cu (1,0 – 10000) mg/kg Mn (1,0 – 11000) mg/kg Mo (1,0 – 2000) mg/kg Ni (1,0 – 10000) mg/kg Pb (10,0 – 17000) mg/kg Sb (2,0 – 2000) mg/kg Se (2,0 – 2000) mg/kg Sn (1,0 – 2000) mg/kg Zn (1,0 – 21200) mg/kg Inductively coupled plasma optical emission spectrometry method (ICP- OES) PN-EN 13657:2006 PN-EN ISO 11885:2009 Odpady O): kod 01 03 80, 01 03 81 Solid wastesO): code 01 03 80, 01 03 81 Zawartosc pierwiastkow Zakres: As (2,0 – 2800) mg/kg Ba (2,0 – 2200) mg/kg Cd (1,0 – 10000) mg/kg Co (1,0 – 10000) mg/kg Cr (1,0 – 10000) mg/kg Cu (1,0 – 10000) mg/kg Mn (1,0 – 11000) mg/kg Mo (1,0 – 2000) mg/kg Ni (1,0 – 10000) mg/kg Pb (10,0 – 17000) mg/kg Sb (2,0 – 2000) mg/kg Se (2,0 – 2000) mg/kg Sn (1,0 – 2000) mg/kg Zn (1,0 – 21200) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Elements content Range: As (2,0 – 2800) mg/kg Ba (2,0 – 2200) mg/kg Cd (1,0 – 10000) mg/kg Co (1,0 – 10000) mg/kg Cr (1,0 – 10000) mg/kg Cu (1,0 – 10000) mg/kg Mn (1,0 – 11000) mg/kg Mo (1,0 – 2000) mg/kg Ni (1,0 – 10000) mg/kg Pb (10,0 – 17000) mg/kg Sb (2,0 – 2000) mg/kg Se (2,0 – 2000) mg/kg Sn (1,0 – 2000) mg/kg Zn (1,0 – 21200) mg/kg Inductively coupled plasma optical emission spectrometry method (ICP- OES) PN-EN 13657:2006 PN-EN ISO 11885:2009","categories":["environment"],"row_index":407,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 01 03 80, 01 03 81 Elements content Range: As (2,0 – 2800) mg/kg Ba (2,0 – 2200) mg/kg Cd (1,0 – 10000) mg/kg Co (1,0 – 10000) mg/kg Cr (1,0 – 10000) mg/kg Cu (1,0 – 10000) mg/kg Mn (1,0 – 11000) mg/kg Mo (1,0 – 2000) mg/kg Ni (1,0 – 10000) mg/kg Pb (10,0 – 17000) mg/kg Sb (2,0 – 2000) mg/kg Se (2,0 – 2000) mg/kg Sn (1,0 – 2000) mg/kg Zn (1,0 – 21200) mg/kg Inductively coupled plasma optical emission spectrometry method (ICP- OES) PN-EN 13657:2006 PN-EN ISO 11885:2009"},{"_id":"6a5a55ef9af9f73f38250c34","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod 19 08 05 Osady ściekowe Solid wastesO): code 19 08 05 Sewage sludge","test_object_en":"Solid wastesO): code 19 08 05 Sewage sludge","methodology":"Zawartość strat przy prażeniu – zawartość substancji organicznej Zakres: (25,00 – 90,00) % m/m Metoda wagowa Loss on ignition content – organic matter content Range: (25,00 – 90,00) % m/m Gravimetric method","methodology_en":"Loss on ignition content – organic matter content Range: (25,00 – 90,00) % m/m Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość strat przy prażeniu – zawartość substancji organicznej Zakres: (25,00 – 90,00) % m/m Metoda wagowa Loss on ignition content – organic matter content Range: (25,00 – 90,00) % m/m Gravimetric method","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 19 08 05 Osady ściekowe Solid wastesO): code 19 08 05 Sewage sludge Zawartość strat przy prażeniu – zawartość substancji organicznej Zakres: (25,00 – 90,00) % m/m Metoda wagowa Loss on ignition content – organic matter content Range: (25,00 – 90,00) % m/m Gravimetric method PN-EN 15935:2022-01 Odpady O): kod 19 08 05 Osady sciekowe Solid wastesO): code 19 08 05 Sewage sludge Zawartosc strat przy prazeniu – zawartosc substancji organicznej Zakres: (25,00 – 90,00) % m/m Metoda wagowa Loss on ignition content – organic matter content Range: (25,00 – 90,00) % m/m Gravimetric method PN-EN 15935:2022-01","categories":["water","environment"],"row_index":408,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 19 08 05 Sewage sludge Loss on ignition content – organic matter content Range: (25,00 – 90,00) % m/m Gravimetric method PN-EN 15935:2022-01"},{"_id":"6a5a55ef9af9f73f38250c35","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste","test_object_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste","methodology":"Zawartość wody i suchej masy Zakres: (0,20 – 60,0) %m/m Metoda wagowa Water and dry matter contents Range: (0,20 – 60,0) %m/m Gravimetric method","methodology_en":"Water and dry matter contents Range: (0,20 – 60,0) %m/m Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wody i suchej masy Zakres: (0,20 – 60,0) %m/m Metoda wagowa Water and dry matter contents Range: (0,20 – 60,0) %m/m Gravimetric method","reference":"PN-EN 15934:2013-02","norm_bases":["PN-EN 15934:2013-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Zawartość wody i suchej masy Zakres: (0,20 – 60,0) %m/m Metoda wagowa Water and dry matter contents Range: (0,20 – 60,0) %m/m Gravimetric method PN-EN 15934:2013-02 Odpady O): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Zuzle, popioly paleniskowe i pyly z kotlow, popioly lotne z wegla, stale odpady z wapniowych metod odsiarczania gazow odlotowych, piaski ze zloz fluidalnych, mieszaniny popiolow lotnych i odpadow stalych z wapniowych metod odsiarczania gazow odlotowych, mieszanki popiolowo-zuzlowe z mokrego odprowadzania odpadow paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Zawartosc wody i suchej masy Zakres: (0,20 – 60,0) %m/m Metoda wagowa Water and dry matter contents Range: (0,20 – 60,0) %m/m Gravimetric method PN-EN 15934:2013-02","categories":["environment","water"],"row_index":409,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Water and dry matter contents Range: (0,20 – 60,0) %m/m Gravimetric method PN-EN 15934:2013-02","search_zh":"废物 O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 PN-EN 15934:2013-02","test_object_zh":"废物 O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12"},{"_id":"6a5a55ef9af9f73f38250c36","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste","test_object_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste","methodology":"Zawartość popiołu Zakres: (0,10 – 99,0) %m/m Metoda wagowa Zawartość strat prażenia (z obliczeń) Ash content Range: (0,10 – 99,0) %m/m Gravimetric method Loss on ignition content (from calculations)","methodology_en":"Ash content Range: (0,10 – 99,0) %m/m Gravimetric method Loss on ignition content (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość popiołu Zakres: (0,10 – 99,0) %m/m Metoda wagowa Zawartość strat prażenia (z obliczeń) Ash content Range: (0,10 – 99,0) %m/m Gravimetric method Loss on ignition content (from calculations)","reference":"SO-4/ZLGIG/PB.03 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.03 ed. 1st of 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.03 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.03 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Zawartość popiołu Zakres: (0,10 – 99,0) %m/m Metoda wagowa Zawartość strat prażenia (z obliczeń) Ash content Range: (0,10 – 99,0) %m/m Gravimetric method Loss on ignition content (from calculations) SO-4/ZLGIG/PB.03 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.03 ed. 1st of 01/08/2025 Odpady O): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Zuzle, popioly paleniskowe i pyly z kotlow, popioly lotne z wegla, stale odpady z wapniowych metod odsiarczania gazow odlotowych, piaski ze zloz fluidalnych, mieszaniny popiolow lotnych i odpadow stalych z wapniowych metod odsiarczania gazow odlotowych, mieszanki popiolowo-zuzlowe z mokrego odprowadzania odpadow paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Zawartosc popiolu Zakres: (0,10 – 99,0) %m/m Metoda wagowa Zawartosc strat prazenia (z obliczen) Ash content Range: (0,10 – 99,0) %m/m Gravimetric method Loss on ignition content (from calculations) SO-4/ZLGIG/PB.03 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.03 ed. 1st of 01/08/2025","categories":["environment"],"row_index":410,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ash content Range: (0,10 – 99,0) %m/m Gravimetric method Loss on ignition content (from calculations) SO-4/ZLGIG/PB.03 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.03 ed. 1st of 01/08/2025","search_zh":"废物 O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 SO-4/ZLGIG/PB.03 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.03 ed. 1st of 01/08/2025","test_object_zh":"废物 O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12"},{"_id":"6a5a55ef9af9f73f38250c37","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste","test_object_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste","methodology":"Zawartość węgla nieorganicznego (TIC) Zakres: (0,03 – 14,00) %m/m Metoda spektrometrii w zakresie podczerwieni (IR) Zawartość węgla organicznego (TOC) (z obliczeń) Content of Total Inorganic carbon (TIC) Range: (0,03 – 14,00) %m/m Infrared spectrometry method (IR) Content of Organic carbon (TOC) (from calculations)","methodology_en":"Content of Total Inorganic carbon (TIC) Range: (0,03 – 14,00) %m/m Infrared spectrometry method (IR) Content of Organic carbon (TOC) (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość węgla nieorganicznego (TIC) Zakres: (0,03 – 14,00) %m/m Metoda spektrometrii w zakresie podczerwieni (IR) Zawartość węgla organicznego (TOC) (z obliczeń) Content of Total Inorganic carbon (TIC) Range: (0,03 – 14,00) %m/m Infrared spectrometry method (IR) Content of Organic carbon (TOC) (from calculations)","reference":"PN-EN 15936:2022-07","norm_bases":["PN-EN 15936:2022-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Zawartość węgla nieorganicznego (TIC) Zakres: (0,03 – 14,00) %m/m Metoda spektrometrii w zakresie podczerwieni (IR) Zawartość węgla organicznego (TOC) (z obliczeń) Content of Total Inorganic carbon (TIC) Range: (0,03 – 14,00) %m/m Infrared spectrometry method (IR) Content of Organic carbon (TOC) (from calculations) PN-EN 15936:2022-07 Odpady O): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Zuzle, popioly paleniskowe i pyly z kotlow, popioly lotne z wegla, stale odpady z wapniowych metod odsiarczania gazow odlotowych, piaski ze zloz fluidalnych, mieszaniny popiolow lotnych i odpadow stalych z wapniowych metod odsiarczania gazow odlotowych, mieszanki popiolowo-zuzlowe z mokrego odprowadzania odpadow paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Zawartosc wegla nieorganicznego (TIC) Zakres: (0,03 – 14,00) %m/m Metoda spektrometrii w zakresie podczerwieni (IR) Zawartosc wegla organicznego (TOC) (z obliczen) Content of Total Inorganic carbon (TIC) Range: (0,03 – 14,00) %m/m Infrared spectrometry method (IR) Content of Organic carbon (TOC) (from calculations) PN-EN 15936:2022-07","categories":["environment"],"row_index":411,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Content of Total Inorganic carbon (TIC) Range: (0,03 – 14,00) %m/m Infrared spectrometry method (IR) Content of Organic carbon (TOC) (from calculations) PN-EN 15936:2022-07","search_zh":"废物 O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 PN-EN 15936:2022-07","test_object_zh":"废物 O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12"},{"_id":"6a5a55ef9af9f73f38250c38","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste","test_object_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste","methodology":"Zawartość rtęci Zakres: (0,01 – 20) mg/kg Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry with amalgamation","methodology_en":"Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry with amalgamation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość rtęci Zakres: (0,01 – 20) mg/kg Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry with amalgamation","reference":"SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1 of 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1 of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Zawartość rtęci Zakres: (0,01 – 20) mg/kg Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry with amalgamation SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1 of 01/08/2025 Odpady O): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Zuzle, popioly paleniskowe i pyly z kotlow, popioly lotne z wegla, stale odpady z wapniowych metod odsiarczania gazow odlotowych, piaski ze zloz fluidalnych, mieszaniny popiolow lotnych i odpadow stalych z wapniowych metod odsiarczania gazow odlotowych, mieszanki popiolowo-zuzlowe z mokrego odprowadzania odpadow paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Zawartosc rteci Zakres: (0,01 – 20) mg/kg Metoda absorpcyjnej spektrometrii atomowej z technika amalgamacji Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry with amalgamation SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1 of 01/08/2025","categories":["environment"],"row_index":412,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime- based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Mercury content Range: (0,01 – 20) mg/kg Atomic absorption spectrometry with amalgamation SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1 of 01/08/2025","search_zh":"废物 O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 SO-4/ZLGIG/PB.23 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.23 ed. 1 of 01/08/2025","test_object_zh":"废物 O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12"},{"_id":"6a5a55ef9af9f73f38250c39","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste","test_object_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste","methodology":"Zawartość pierwiastków Zakres: As (1,0 – 100000) mg/kg Ba (1,0 – 100000) mg/kg Cd (1,0 – 100000) mg/kg Co (1,0 – 100000) mg/kg Cr (1,0 – 100000) mg/kg Cu (1,0 – 100000) mg/kg Mn (1,0 – 100000) mg/kg Mo (1,0 – 100000) mg/kg Ni (1,0 – 100000) mg/kg Pb (1,0 – 100000) mg/kg Sb (1,0 – 100000) mg/kg Se (2,0 – 100000) mg/kg Sn (1,0 – 100000) mg/kg Zn (1,0 – 100000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Elements content Range: As (1,0 – 100000) mg/kg Ba (1,0 – 100000) mg/kg Cd (1,0 – 100000) mg/kg Co (1,0 – 100000) mg/kg Cr (1,0 – 100000) mg/kg Cu (1,0 – 100000) mg/kg Mn (1,0 – 100000) mg/kg Mo (1,0 – 100000) mg/kg Ni (1,0 – 100000) mg/kg Pb (1,0 – 100000) mg/kg Sb (1,0 – 100000) mg/kg Se (2,0 – 100000) mg/kg Sn (1,0 – 100000) mg/kg Zn (1,0 – 100000) mg/kg Inductively coupled plasma optical emission spectrometry metod (ICP-OES)","methodology_en":"Elements content Range: As (1,0 – 100000) mg/kg Ba (1,0 – 100000) mg/kg Cd (1,0 – 100000) mg/kg Co (1,0 – 100000) mg/kg Cr (1,0 – 100000) mg/kg Cu (1,0 – 100000) mg/kg Mn (1,0 – 100000) mg/kg Mo (1,0 – 100000) mg/kg Ni (1,0 – 100000) mg/kg Pb (1,0 – 100000) mg/kg Sb (1,0 – 100000) mg/kg Se (2,0 – 100000) mg/kg Sn (1,0 – 100000) mg/kg Zn (1,0 – 100000) mg/kg Inductively coupled plasma optical emission spectrometry metod (ICP-OES)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość pierwiastków Zakres: As (1,0 – 100000) mg/kg Ba (1,0 – 100000) mg/kg Cd (1,0 – 100000) mg/kg Co (1,0 – 100000) mg/kg Cr (1,0 – 100000) mg/kg Cu (1,0 – 100000) mg/kg Mn (1,0 – 100000) mg/kg Mo (1,0 – 100000) mg/kg Ni (1,0 – 100000) mg/kg Pb (1,0 – 100000) mg/kg Sb (1,0 – 100000) mg/kg Se (2,0 – 100000) mg/kg Sn (1,0 – 100000) mg/kg Zn (1,0 – 100000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Elements content Range: As (1,0 – 100000) mg/kg Ba (1,0 – 100000) mg/kg Cd (1,0 – 100000) mg/kg Co (1,0 – 100000) mg/kg Cr (1,0 – 100000) mg/kg Cu (1,0 – 100000) mg/kg Mn (1,0 – 100000) mg/kg Mo (1,0 – 100000) mg/kg Ni (1,0 – 100000) mg/kg Pb (1,0 – 100000) mg/kg Sb (1,0 – 100000) mg/kg Se (2,0 – 100000) mg/kg Sn (1,0 – 100000) mg/kg Zn (1,0 – 100000) mg/kg Inductively coupled plasma optical emission spectrometry metod (ICP-OES)","reference":"PN-EN 13657:2006 PN-EN ISO 11885:2009","norm_bases":["PN-EN 13657:2006 PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Zawartość pierwiastków Zakres: As (1,0 – 100000) mg/kg Ba (1,0 – 100000) mg/kg Cd (1,0 – 100000) mg/kg Co (1,0 – 100000) mg/kg Cr (1,0 – 100000) mg/kg Cu (1,0 – 100000) mg/kg Mn (1,0 – 100000) mg/kg Mo (1,0 – 100000) mg/kg Ni (1,0 – 100000) mg/kg Pb (1,0 – 100000) mg/kg Sb (1,0 – 100000) mg/kg Se (2,0 – 100000) mg/kg Sn (1,0 – 100000) mg/kg Zn (1,0 – 100000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Elements content Range: As (1,0 – 100000) mg/kg Ba (1,0 – 100000) mg/kg Cd (1,0 – 100000) mg/kg Co (1,0 – 100000) mg/kg Cr (1,0 – 100000) mg/kg Cu (1,0 – 100000) mg/kg Mn (1,0 – 100000) mg/kg Mo (1,0 – 100000) mg/kg Ni (1,0 – 100000) mg/kg Pb (1,0 – 100000) mg/kg Sb (1,0 – 100000) mg/kg Se (2,0 – 100000) mg/kg Sn (1,0 – 100000) mg/kg Zn (1,0 – 100000) mg/kg Inductively coupled plasma optical emission spectrometry metod (ICP-OES) PN-EN 13657:2006 PN-EN ISO 11885:2009 Odpady O): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Zuzle, popioly paleniskowe i pyly z kotlow, popioly lotne z wegla, stale odpady z wapniowych metod odsiarczania gazow odlotowych, piaski ze zloz fluidalnych, mieszaniny popiolow lotnych i odpadow stalych z wapniowych metod odsiarczania gazow odlotowych, mieszanki popiolowo-zuzlowe z mokrego odprowadzania odpadow paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Zawartosc pierwiastkow Zakres: As (1,0 – 100000) mg/kg Ba (1,0 – 100000) mg/kg Cd (1,0 – 100000) mg/kg Co (1,0 – 100000) mg/kg Cr (1,0 – 100000) mg/kg Cu (1,0 – 100000) mg/kg Mn (1,0 – 100000) mg/kg Mo (1,0 – 100000) mg/kg Ni (1,0 – 100000) mg/kg Pb (1,0 – 100000) mg/kg Sb (1,0 – 100000) mg/kg Se (2,0 – 100000) mg/kg Sn (1,0 – 100000) mg/kg Zn (1,0 – 100000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Elements content Range: As (1,0 – 100000) mg/kg Ba (1,0 – 100000) mg/kg Cd (1,0 – 100000) mg/kg Co (1,0 – 100000) mg/kg Cr (1,0 – 100000) mg/kg Cu (1,0 – 100000) mg/kg Mn (1,0 – 100000) mg/kg Mo (1,0 – 100000) mg/kg Ni (1,0 – 100000) mg/kg Pb (1,0 – 100000) mg/kg Sb (1,0 – 100000) mg/kg Se (2,0 – 100000) mg/kg Sn (1,0 – 100000) mg/kg Zn (1,0 – 100000) mg/kg Inductively coupled plasma optical emission spectrometry metod (ICP-OES) PN-EN 13657:2006 PN-EN ISO 11885:2009","categories":["environment"],"row_index":413,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Elements content Range: As (1,0 – 100000) mg/kg Ba (1,0 – 100000) mg/kg Cd (1,0 – 100000) mg/kg Co (1,0 – 100000) mg/kg Cr (1,0 – 100000) mg/kg Cu (1,0 – 100000) mg/kg Mn (1,0 – 100000) mg/kg Mo (1,0 – 100000) mg/kg Ni (1,0 – 100000) mg/kg Pb (1,0 – 100000) mg/kg Sb (1,0 – 100000) mg/kg Se (2,0 – 100000) mg/kg Sn (1,0 – 100000) mg/kg Zn (1,0 – 100000) mg/kg Inductively coupled plasma optical emission spectrometry metod (ICP-OES) PN-EN 13657:2006 PN-EN ISO 11885:2009","search_zh":"废物 O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料 Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste PN-EN 13657:2006 PN-EN ISO 11885:2009","test_object_zh":"废物 O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料 Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste"},{"_id":"6a5a55ef9af9f73f38250c3a","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste","test_object_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste","methodology":"Zawartość węgla całkowitego, siarki całkowitej oraz wodoru całkowitego, oraz obliczenie zawartości wodoru niezwiązanego z wilgocią Zakres: C (0,12 – 50,00) %m/m H (0,11 – 20,00) %m/m S (0,03 – 13,70) %m/m Metoda wysokotemperaturowego spalania z detekcją IR Total carbon, total sulfur and total hydrogen content, and calculation of non- moisture hydrogen content Range: C (0,12 – 50,00) %m/m H (0,11 – 20,00) %m/m S (0,03 – 13,70) %m/m High temp. combustion method with IR detection","methodology_en":"Total carbon, total sulfur and total hydrogen content, and calculation of non- moisture hydrogen content Range: C (0,12 – 50,00) %m/m H (0,11 – 20,00) %m/m S (0,03 – 13,70) %m/m High temp. combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego, siarki całkowitej oraz wodoru całkowitego, oraz obliczenie zawartości wodoru niezwiązanego z wilgocią Zakres: C (0,12 – 50,00) %m/m H (0,11 – 20,00) %m/m S (0,03 – 13,70) %m/m Metoda wysokotemperaturowego spalania z detekcją IR Total carbon, total sulfur and total hydrogen content, and calculation of non- moisture hydrogen content Range: C (0,12 – 50,00) %m/m H (0,11 – 20,00) %m/m S (0,03 – 13,70) %m/m High temp. combustion method with IR detection","reference":"SO-4/ZLGIG/PB.04 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.04 ed. 1st 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.04 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.04 ed. 1st 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Zawartość węgla całkowitego, siarki całkowitej oraz wodoru całkowitego, oraz obliczenie zawartości wodoru niezwiązanego z wilgocią Zakres: C (0,12 – 50,00) %m/m H (0,11 – 20,00) %m/m S (0,03 – 13,70) %m/m Metoda wysokotemperaturowego spalania z detekcją IR Total carbon, total sulfur and total hydrogen content, and calculation of non- moisture hydrogen content Range: C (0,12 – 50,00) %m/m H (0,11 – 20,00) %m/m S (0,03 – 13,70) %m/m High temp. combustion method with IR detection SO-4/ZLGIG/PB.04 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.04 ed. 1st 01/08/2025 Odpady O): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Zuzle, popioly paleniskowe i pyly z kotlow, popioly lotne z wegla, stale odpady z wapniowych metod odsiarczania gazow odlotowych, piaski ze zloz fluidalnych, mieszaniny popiolow lotnych i odpadow stalych z wapniowych metod odsiarczania gazow odlotowych, mieszanki popiolowo-zuzlowe z mokrego odprowadzania odpadow paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Zawartosc wegla calkowitego, siarki calkowitej oraz wodoru calkowitego, oraz obliczenie zawartosci wodoru niezwiazanego z wilgocia Zakres: C (0,12 – 50,00) %m/m H (0,11 – 20,00) %m/m S (0,03 – 13,70) %m/m Metoda wysokotemperaturowego spalania z detekcja IR Total carbon, total sulfur and total hydrogen content, and calculation of non- moisture hydrogen content Range: C (0,12 – 50,00) %m/m H (0,11 – 20,00) %m/m S (0,03 – 13,70) %m/m High temp. combustion method with IR detection SO-4/ZLGIG/PB.04 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.04 ed. 1st 01/08/2025","categories":["environment"],"row_index":414,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Total carbon, total sulfur and total hydrogen content, and calculation of non- moisture hydrogen content Range: C (0,12 – 50,00) %m/m H (0,11 – 20,00) %m/m S (0,03 – 13,70) %m/m High temp. combustion method with IR detection SO-4/ZLGIG/PB.04 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.04 ed. 1st 01/08/2025","search_zh":"废物 O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料 Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste SO-4/ZLGIG/PB.04 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.04 ed. 1st 01/08/2025","test_object_zh":"废物 O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料 Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste"},{"_id":"6a5a55ef9af9f73f38250c3b","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste","test_object_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste","methodology":"Ciepło spalania Zakres: (4030 – 40000) kJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń) Gross calorific value Range:(4030 – 40000) kJ/kg Calorimetric method Net calorific value (from calculations)","methodology_en":"Gross calorific value Range:(4030 – 40000) kJ/kg Calorimetric method Net calorific value (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciepło spalania Zakres: (4030 – 40000) kJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń) Gross calorific value Range:(4030 – 40000) kJ/kg Calorimetric method Net calorific value (from calculations)","reference":"SO-4/ZLGIG/PB.22 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.22 ed. 1st of 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.22 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.22 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Ciepło spalania Zakres: (4030 – 40000) kJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń) Gross calorific value Range:(4030 – 40000) kJ/kg Calorimetric method Net calorific value (from calculations) SO-4/ZLGIG/PB.22 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.22 ed. 1st of 01/08/2025 Odpady O): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Zuzle, popioly paleniskowe i pyly z kotlow, popioly lotne z wegla, stale odpady z wapniowych metod odsiarczania gazow odlotowych, piaski ze zloz fluidalnych, mieszaniny popiolow lotnych i odpadow stalych z wapniowych metod odsiarczania gazow odlotowych, mieszanki popiolowo-zuzlowe z mokrego odprowadzania odpadow paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Cieplo spalania Zakres: (4030 – 40000) kJ/kg Metoda kalorymetryczna Wartosc opalowa (z obliczen) Gross calorific value Range:(4030 – 40000) kJ/kg Calorimetric method Net calorific value (from calculations) SO-4/ZLGIG/PB.22 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.22 ed. 1st of 01/08/2025","categories":["environment"],"row_index":415,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Gross calorific value Range:(4030 – 40000) kJ/kg Calorimetric method Net calorific value (from calculations) SO-4/ZLGIG/PB.22 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.22 ed. 1st of 01/08/2025","search_zh":"废物 O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料 Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste SO-4/ZLGIG/PB.22 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.22 ed. 1st of 01/08/2025","test_object_zh":"废物 O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料 Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste"},{"_id":"6a5a55ef9af9f73f38250c3c","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste","test_object_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste","methodology":"Zawartość azotu Kjeldahla Zakres: (0,15 – 5,60) %m/m Metoda miareczkowa Kjeldahl’s nitrogen content Range: (0.15 – 5.60) %m/m Titrimetric method","methodology_en":"Kjeldahl’s nitrogen content Range: (0.15 – 5.60) %m/m Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość azotu Kjeldahla Zakres: (0,15 – 5,60) %m/m Metoda miareczkowa Kjeldahl’s nitrogen content Range: (0.15 – 5.60) %m/m Titrimetric method","reference":"SO-4/ZLGIG/PB.14 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.14 ed. 1st of 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.14 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.14 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Zawartość azotu Kjeldahla Zakres: (0,15 – 5,60) %m/m Metoda miareczkowa Kjeldahl’s nitrogen content Range: (0.15 – 5.60) %m/m Titrimetric method SO-4/ZLGIG/PB.14 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.14 ed. 1st of 01/08/2025 Odpady O): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Zuzle, popioly paleniskowe i pyly z kotlow, popioly lotne z wegla, stale odpady z wapniowych metod odsiarczania gazow odlotowych, piaski ze zloz fluidalnych, mieszaniny popiolow lotnych i odpadow stalych z wapniowych metod odsiarczania gazow odlotowych, mieszanki popiolowo-zuzlowe z mokrego odprowadzania odpadow paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Zawartosc azotu Kjeldahla Zakres: (0,15 – 5,60) %m/m Metoda miareczkowa Kjeldahl’s nitrogen content Range: (0.15 – 5.60) %m/m Titrimetric method SO-4/ZLGIG/PB.14 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.14 ed. 1st of 01/08/2025","categories":["environment"],"row_index":416,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Kjeldahl’s nitrogen content Range: (0.15 – 5.60) %m/m Titrimetric method SO-4/ZLGIG/PB.14 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.14 ed. 1st of 01/08/2025","search_zh":"废物 O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料 Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste SO-4/ZLGIG/PB.14 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.14 ed. 1st of 01/08/2025","test_object_zh":"废物 O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料 Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste"},{"_id":"6a5a55ef9af9f73f38250c3d","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste","test_object_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste","methodology":"Zawartość chloru Zakres: (0,07 – 60,7) %m/m Metoda miareczkowa Chlorine content Range:(0,07 – 60,7) %m/m Titrimetric method","methodology_en":"Chlorine content Range:(0,07 – 60,7) %m/m Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość chloru Zakres: (0,07 – 60,7) %m/m Metoda miareczkowa Chlorine content Range:(0,07 – 60,7) %m/m Titrimetric method","reference":"SO-4/ZLGIG/PB.17 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.17 ed. 1st 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.17 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.17 ed. 1st 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Zawartość chloru Zakres: (0,07 – 60,7) %m/m Metoda miareczkowa Chlorine content Range:(0,07 – 60,7) %m/m Titrimetric method SO-4/ZLGIG/PB.17 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.17 ed. 1st 01/08/2025 Odpady O): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Zuzle, popioly paleniskowe i pyly z kotlow, popioly lotne z wegla, stale odpady z wapniowych metod odsiarczania gazow odlotowych, piaski ze zloz fluidalnych, mieszaniny popiolow lotnych i odpadow stalych z wapniowych metod odsiarczania gazow odlotowych, mieszanki popiolowo-zuzlowe z mokrego odprowadzania odpadow paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Zawartosc chloru Zakres: (0,07 – 60,7) %m/m Metoda miareczkowa Chlorine content Range:(0,07 – 60,7) %m/m Titrimetric method SO-4/ZLGIG/PB.17 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.17 ed. 1st 01/08/2025","categories":["environment"],"row_index":417,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Chlorine content Range:(0,07 – 60,7) %m/m Titrimetric method SO-4/ZLGIG/PB.17 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.17 ed. 1st 01/08/2025","search_zh":"废物 O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料 Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste SO-4/ZLGIG/PB.17 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.17 ed. 1st 01/08/2025","test_object_zh":"废物 O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料 Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste"},{"_id":"6a5a55ef9af9f73f38250c3e","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste","test_object_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste","methodology":"Zawartość chlorków Zakres: (0,08 – 68,00) %m/m Metoda miareczkowa Chlorides content Range: (0,08 – 68,00) %m/m Titrimetric method","methodology_en":"Chlorides content Range: (0,08 – 68,00) %m/m Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość chlorków Zakres: (0,08 – 68,00) %m/m Metoda miareczkowa Chlorides content Range: (0,08 – 68,00) %m/m Titrimetric method","reference":"SO-4/ZLGIG/PB.18 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.18 ed. 1st 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.18 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.18 ed. 1st 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Zawartość chlorków Zakres: (0,08 – 68,00) %m/m Metoda miareczkowa Chlorides content Range: (0,08 – 68,00) %m/m Titrimetric method SO-4/ZLGIG/PB.18 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.18 ed. 1st 01/08/2025 Odpady O): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Zuzle, popioly paleniskowe i pyly z kotlow, popioly lotne z wegla, stale odpady z wapniowych metod odsiarczania gazow odlotowych, piaski ze zloz fluidalnych, mieszaniny popiolow lotnych i odpadow stalych z wapniowych metod odsiarczania gazow odlotowych, mieszanki popiolowo-zuzlowe z mokrego odprowadzania odpadow paleniskowych Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Zawartosc chlorkow Zakres: (0,08 – 68,00) %m/m Metoda miareczkowa Chlorides content Range: (0,08 – 68,00) %m/m Titrimetric method SO-4/ZLGIG/PB.18 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.18 ed. 1st 01/08/2025","categories":["environment"],"row_index":418,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Chlorides content Range: (0,08 – 68,00) %m/m Titrimetric method SO-4/ZLGIG/PB.18 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.18 ed. 1st 01/08/2025","search_zh":"废物 O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料 Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste SO-4/ZLGIG/PB.18 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.18 ed. 1st 01/08/2025","test_object_zh":"废物 O)：代码 01 01 02、01 03 06、01 04 12、01 04 81、10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 17、10 01 24、10 01 25、10 01 80、10 01 82、10 09 08、17 01 01、17 01 02、17 01 81、17 05 04、17 05 08、17 09 04、19 01 12、19 08 01、19 08 02、19 08 05、19 08 14、19 09 01、19 09 02、19 12 09、19 13 06；炉渣、炉底灰与锅炉粉尘、燃煤飞灰、钙法烟气脱硫产生的固体废物、流化床砂、飞灰与钙法烟气脱硫固体废物的混合物、燃烧废物湿排产生的灰渣混合料 Solid wastesO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 09, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste"},{"_id":"6a5a55ef9af9f73f38250c3f","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe Solid fuels: solid biomass - solid biofuel","test_object_en":"Solid fuels: solid biomass - solid biofuel","methodology":"Zawartość wilgoci analitycznej Zakres: (0,10 – 20,0) %m/m Metoda wagowa Analytical moisture content Range: (0,10 – 20,0) %m/m Gravimetric method","methodology_en":"Analytical moisture content Range: (0,10 – 20,0) %m/m Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci analitycznej Zakres: (0,10 – 20,0) %m/m Metoda wagowa Analytical moisture content Range: (0,10 – 20,0) %m/m Gravimetric method","reference":"PN-EN ISO 18134-3:2023-12","norm_bases":["PN-EN ISO 18134-3:2023-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe Solid fuels: solid biomass - solid biofuel Zawartość wilgoci analitycznej Zakres: (0,10 – 20,0) %m/m Metoda wagowa Analytical moisture content Range: (0,10 – 20,0) %m/m Gravimetric method PN-EN ISO 18134-3:2023-12 Paliwa stale: biomasa stala - biopaliwo stale Solid fuels: solid biomass - solid biofuel Zawartosc wilgoci analitycznej Zakres: (0,10 – 20,0) %m/m Metoda wagowa Analytical moisture content Range: (0,10 – 20,0) %m/m Gravimetric method PN-EN ISO 18134-3:2023-12","categories":["petro"],"row_index":419,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid biomass - solid biofuel Analytical moisture content Range: (0,10 – 20,0) %m/m Gravimetric method PN-EN ISO 18134-3:2023-12","search_zh":"固体燃料：固体生物质 － 固体生物燃料 Solid fuels: solid biomass - solid biofuel PN-EN ISO 18134-3:2023-12","test_object_zh":"固体燃料：固体生物质 － 固体生物燃料 Solid fuels: solid biomass - solid biofuel"},{"_id":"6a5a55ef9af9f73f38250c40","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe Solid fuels: solid biomass - solid biofuel","test_object_en":"Solid fuels: solid biomass - solid biofuel","methodology":"Zawartość wilgoci całkowitej Zakres: (0,50 – 55,0) %m/m Metoda wagowa Total moisture content Range: (0,50 – 55,0) %m/m Gravimetric method","methodology_en":"Total moisture content Range: (0,50 – 55,0) %m/m Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej Zakres: (0,50 – 55,0) %m/m Metoda wagowa Total moisture content Range: (0,50 – 55,0) %m/m Gravimetric method","reference":"PN-EN ISO 18134-2:2017-03","norm_bases":["PN-EN ISO 18134-2:2017-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe Solid fuels: solid biomass - solid biofuel Zawartość wilgoci całkowitej Zakres: (0,50 – 55,0) %m/m Metoda wagowa Total moisture content Range: (0,50 – 55,0) %m/m Gravimetric method PN-EN ISO 18134-2:2017-03 Paliwa stale: biomasa stala - biopaliwo stale Solid fuels: solid biomass - solid biofuel Zawartosc wilgoci calkowitej Zakres: (0,50 – 55,0) %m/m Metoda wagowa Total moisture content Range: (0,50 – 55,0) %m/m Gravimetric method PN-EN ISO 18134-2:2017-03","categories":["petro"],"row_index":420,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid biomass - solid biofuel Total moisture content Range: (0,50 – 55,0) %m/m Gravimetric method PN-EN ISO 18134-2:2017-03","search_zh":"固体燃料：固体生物质 － 固体生物燃料 Solid fuels: solid biomass - solid biofuel PN-EN ISO 18134-2:2017-03","test_object_zh":"固体燃料：固体生物质 － 固体生物燃料 Solid fuels: solid biomass - solid biofuel"},{"_id":"6a5a55ef9af9f73f38250c41","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe Solid fuels: solid biomass - solid biofuel","test_object_en":"Solid fuels: solid biomass - solid biofuel","methodology":"Zawartość popiołu Zakres: (0,10 – 50,0) %m/m Metoda wagowa Ash content Range: (0,10 – 50,0) %m/m Gravimetric method","methodology_en":"Ash content Range: (0,10 – 50,0) %m/m Gravimetric method Ash content Range: (0,10 – 50,0) %m/m Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość popiołu Zakres: (0,10 – 50,0) %m/m Metoda wagowa Ash content Range: (0,10 – 50,0) %m/m Gravimetric method","reference":"PN-EN ISO 18122:2023-05","norm_bases":["PN-EN ISO 18122:2023-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe Solid fuels: solid biomass - solid biofuel Zawartość popiołu Zakres: (0,10 – 50,0) %m/m Metoda wagowa Ash content Range: (0,10 – 50,0) %m/m Gravimetric method PN-EN ISO 18122:2023-05 Paliwa stale: biomasa stala - biopaliwo stale Solid fuels: solid biomass - solid biofuel Zawartosc popiolu Zakres: (0,10 – 50,0) %m/m Metoda wagowa Ash content Range: (0,10 – 50,0) %m/m Gravimetric method PN-EN ISO 18122:2023-05","categories":["petro"],"row_index":421,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid biomass - solid biofuel Ash content Range: (0,10 – 50,0) %m/m Gravimetric method Ash content Range: (0,10 – 50,0) %m/m Gravimetric method PN-EN ISO 18122:2023-05","search_zh":"固体燃料：固体生物质 － 固体生物燃料 Solid fuels: solid biomass - solid biofuel PN-EN ISO 18122:2023-05","test_object_zh":"固体燃料：固体生物质 － 固体生物燃料 Solid fuels: solid biomass - solid biofuel"},{"_id":"6a5a55ef9af9f73f38250c42","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe Solid fuels: solid biomass - solid biofuel","test_object_en":"Solid fuels: solid biomass - solid biofuel","methodology":"Zawartość tlenków Zakres: SiO (5,42 – 66,04) %m/m 2 Al O (0,36 – 7,90) %m/m 2 3 Fe O (0,48 – 23,00) %m/m 2 3 CaO (2,91 – 41,94) %m/m MgO (0,80 – 8,91) %m/m Na O (0,16 – 3,89) %m/m 2 K O (0,64 – 25,17) %m/m 2 SO (0,32 – 7,17) %m/m 3 TiO (0,02 – 0,90) %m/m 2 P O (0,75 – 27,96) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Oxides content Range: SiO (5,42 – 66,04) %m/m 2 Al O (0,36 – 7,90) %m/m 2 3 Fe O (0,48 – 23,00) %m/m 2 3 CaO (2,91 – 41,94) %m/m MgO (0,80 – 8,91) %m/m Na O (0,16 – 3,89) %m/m 2 K O (0,64 – 25,17) %m/m 2 SO (0,32 – 7,17) %m/m 3 TiO (0,02 – 0,90) %m/m 2 P O (0,75 – 27,96) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","methodology_en":"Oxides content Range: SiO (5,42 – 66,04) %m/m 2 Al O (0,36 – 7,90) %m/m 2 3 Fe O (0,48 – 23,00) %m/m 2 3 CaO (2,91 – 41,94) %m/m MgO (0,80 – 8,91) %m/m Na O (0,16 – 3,89) %m/m 2 K O (0,64 – 25,17) %m/m 2 SO (0,32 – 7,17) %m/m 3 TiO (0,02 – 0,90) %m/m 2 P O (0,75 – 27,96) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość tlenków Zakres: SiO (5,42 – 66,04) %m/m 2 Al O (0,36 – 7,90) %m/m 2 3 Fe O (0,48 – 23,00) %m/m 2 3 CaO (2,91 – 41,94) %m/m MgO (0,80 – 8,91) %m/m Na O (0,16 – 3,89) %m/m 2 K O (0,64 – 25,17) %m/m 2 SO (0,32 – 7,17) %m/m 3 TiO (0,02 – 0,90) %m/m 2 P O (0,75 – 27,96) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Oxides content Range: SiO (5,42 – 66,04) %m/m 2 Al O (0,36 – 7,90) %m/m 2 3 Fe O (0,48 – 23,00) %m/m 2 3 CaO (2,91 – 41,94) %m/m MgO (0,80 – 8,91) %m/m Na O (0,16 – 3,89) %m/m 2 K O (0,64 – 25,17) %m/m 2 SO (0,32 – 7,17) %m/m 3 TiO (0,02 – 0,90) %m/m 2 P O (0,75 – 27,96) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","reference":"SO-4/ZLGIG/PB.24 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.24 ed. 1st of 01/08/2025","norm_bases":["SO-4/ZLGIG/PB.24 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.24 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe Solid fuels: solid biomass - solid biofuel Zawartość tlenków Zakres: SiO (5,42 – 66,04) %m/m 2 Al O (0,36 – 7,90) %m/m 2 3 Fe O (0,48 – 23,00) %m/m 2 3 CaO (2,91 – 41,94) %m/m MgO (0,80 – 8,91) %m/m Na O (0,16 – 3,89) %m/m 2 K O (0,64 – 25,17) %m/m 2 SO (0,32 – 7,17) %m/m 3 TiO (0,02 – 0,90) %m/m 2 P O (0,75 – 27,96) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Oxides content Range: SiO (5,42 – 66,04) %m/m 2 Al O (0,36 – 7,90) %m/m 2 3 Fe O (0,48 – 23,00) %m/m 2 3 CaO (2,91 – 41,94) %m/m MgO (0,80 – 8,91) %m/m Na O (0,16 – 3,89) %m/m 2 K O (0,64 – 25,17) %m/m 2 SO (0,32 – 7,17) %m/m 3 TiO (0,02 – 0,90) %m/m 2 P O (0,75 – 27,96) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) SO-4/ZLGIG/PB.24 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.24 ed. 1st of 01/08/2025 Paliwa stale: biomasa stala - biopaliwo stale Solid fuels: solid biomass - solid biofuel Zawartosc tlenkow Zakres: SiO (5,42 – 66,04) %m/m 2 Al O (0,36 – 7,90) %m/m 2 3 Fe O (0,48 – 23,00) %m/m 2 3 CaO (2,91 – 41,94) %m/m MgO (0,80 – 8,91) %m/m Na O (0,16 – 3,89) %m/m 2 K O (0,64 – 25,17) %m/m 2 SO (0,32 – 7,17) %m/m 3 TiO (0,02 – 0,90) %m/m 2 P O (0,75 – 27,96) %m/m 2 5 Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja fali (WD-XRF) Oxides content Range: SiO (5,42 – 66,04) %m/m 2 Al O (0,36 – 7,90) %m/m 2 3 Fe O (0,48 – 23,00) %m/m 2 3 CaO (2,91 – 41,94) %m/m MgO (0,80 – 8,91) %m/m Na O (0,16 – 3,89) %m/m 2 K O (0,64 – 25,17) %m/m 2 SO (0,32 – 7,17) %m/m 3 TiO (0,02 – 0,90) %m/m 2 P O (0,75 – 27,96) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) SO-4/ZLGIG/PB.24 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.24 ed. 1st of 01/08/2025","categories":["petro"],"row_index":422,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid biomass - solid biofuel Oxides content Range: SiO (5,42 – 66,04) %m/m 2 Al O (0,36 – 7,90) %m/m 2 3 Fe O (0,48 – 23,00) %m/m 2 3 CaO (2,91 – 41,94) %m/m MgO (0,80 – 8,91) %m/m Na O (0,16 – 3,89) %m/m 2 K O (0,64 – 25,17) %m/m 2 SO (0,32 – 7,17) %m/m 3 TiO (0,02 – 0,90) %m/m 2 P O (0,75 – 27,96) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) SO-4/ZLGIG/PB.24 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.24 ed. 1st of 01/08/2025","search_zh":"固体燃料：固体生物质 － 固体生物燃料 Solid fuels: solid biomass - solid biofuel SO-4/ZLGIG/PB.24 ed. 1 z dn. 01.08.2025 SO-4/ZLGIG/PB.24 ed. 1st of 01/08/2025","test_object_zh":"固体燃料：固体生物质 － 固体生物燃料 Solid fuels: solid biomass - solid biofuel"},{"_id":"6a5a55ef9af9f73f38250c43","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe Solid fuels: solid biomass - solid biofuel","test_object_en":"Solid fuels: solid biomass - solid biofuel","methodology":"Zawartość węgla całkowitego, wodoru całkowitego Zakres: C (20,0 – 60,0) %m/m H (0,11 – 11,00) %m/m Metoda wysokotemperaturowego spalania z detekcją IR Total carbon, Total hydrogen content Range: C (20,0 – 60,0) %m/m H (0,11 – 11,00) %m/m High temp. combustion method with IR detection","methodology_en":"Total carbon, Total hydrogen content Range: C (20,0 – 60,0) %m/m H (0,11 – 11,00) %m/m High temp. combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego, wodoru całkowitego Zakres: C (20,0 – 60,0) %m/m H (0,11 – 11,00) %m/m Metoda wysokotemperaturowego spalania z detekcją IR Total carbon, Total hydrogen content Range: C (20,0 – 60,0) %m/m H (0,11 – 11,00) %m/m High temp. combustion method with IR detection","reference":"PN-EN ISO 16948:2015-07","norm_bases":["PN-EN ISO 16948:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe Solid fuels: solid biomass - solid biofuel Zawartość węgla całkowitego, wodoru całkowitego Zakres: C (20,0 – 60,0) %m/m H (0,11 – 11,00) %m/m Metoda wysokotemperaturowego spalania z detekcją IR Total carbon, Total hydrogen content Range: C (20,0 – 60,0) %m/m H (0,11 – 11,00) %m/m High temp. combustion method with IR detection PN-EN ISO 16948:2015-07 Paliwa stale: biomasa stala - biopaliwo stale Solid fuels: solid biomass - solid biofuel Zawartosc wegla calkowitego, wodoru calkowitego Zakres: C (20,0 – 60,0) %m/m H (0,11 – 11,00) %m/m Metoda wysokotemperaturowego spalania z detekcja IR Total carbon, Total hydrogen content Range: C (20,0 – 60,0) %m/m H (0,11 – 11,00) %m/m High temp. combustion method with IR detection PN-EN ISO 16948:2015-07","categories":["petro"],"row_index":423,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid biomass - solid biofuel Total carbon, Total hydrogen content Range: C (20,0 – 60,0) %m/m H (0,11 – 11,00) %m/m High temp. combustion method with IR detection PN-EN ISO 16948:2015-07","search_zh":"固体燃料：固体生物质 － 固体生物燃料 Solid fuels: solid biomass - solid biofuel PN-EN ISO 16948:2015-07","test_object_zh":"固体燃料：固体生物质 － 固体生物燃料 Solid fuels: solid biomass - solid biofuel"},{"_id":"6a5a55ef9af9f73f38250c44","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe Solid fuels: solid biomass - solid biofuel","test_object_en":"Solid fuels: solid biomass - solid biofuel","methodology":"Ciepło spalania Zakres: (6 000 – 25 000) kJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń) Gross calorific value Range: (6 000 – 25 000) kJ/kg Calorimetric method Net calorific value (from calculations)","methodology_en":"Gross calorific value Range: (6 000 – 25 000) kJ/kg Calorimetric method Net calorific value (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciepło spalania Zakres: (6 000 – 25 000) kJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń) Gross calorific value Range: (6 000 – 25 000) kJ/kg Calorimetric method Net calorific value (from calculations)","reference":"PN-EN ISO 18125:2017-07","norm_bases":["PN-EN ISO 18125:2017-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe Solid fuels: solid biomass - solid biofuel Ciepło spalania Zakres: (6 000 – 25 000) kJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń) Gross calorific value Range: (6 000 – 25 000) kJ/kg Calorimetric method Net calorific value (from calculations) PN-EN ISO 18125:2017-07 Paliwa stale: biomasa stala - biopaliwo stale Solid fuels: solid biomass - solid biofuel Cieplo spalania Zakres: (6 000 – 25 000) kJ/kg Metoda kalorymetryczna Wartosc opalowa (z obliczen) Gross calorific value Range: (6 000 – 25 000) kJ/kg Calorimetric method Net calorific value (from calculations) PN-EN ISO 18125:2017-07","categories":["petro"],"row_index":424,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid biomass - solid biofuel Gross calorific value Range: (6 000 – 25 000) kJ/kg Calorimetric method Net calorific value (from calculations) PN-EN ISO 18125:2017-07","search_zh":"固体燃料：固体生物质 － 固体生物燃料 Solid fuels: solid biomass - solid biofuel PN-EN ISO 18125:2017-07","test_object_zh":"固体燃料：固体生物质 － 固体生物燃料 Solid fuels: solid biomass - solid biofuel"},{"_id":"6a5a55ef9af9f73f38250c45","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe Solid fuels: solid biomass - solid biofuel","test_object_en":"Solid fuels: solid biomass - solid biofuel","methodology":"Zawartość siarki całkowitej Zakres: (0,03 – 5,00) %m/m Metoda wysokotemperaturowego spalania z detekcją IR Total sulfur content Range: (0,03 – 5,00) %m/m High temp. combustion method with IR detection","methodology_en":"Total sulfur content Range: (0,03 – 5,00) %m/m High temp. combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej Zakres: (0,03 – 5,00) %m/m Metoda wysokotemperaturowego spalania z detekcją IR Total sulfur content Range: (0,03 – 5,00) %m/m High temp. combustion method with IR detection","reference":"PN-EN ISO 16994:2016-10","norm_bases":["PN-EN ISO 16994:2016-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe Solid fuels: solid biomass - solid biofuel Zawartość siarki całkowitej Zakres: (0,03 – 5,00) %m/m Metoda wysokotemperaturowego spalania z detekcją IR Total sulfur content Range: (0,03 – 5,00) %m/m High temp. combustion method with IR detection PN-EN ISO 16994:2016-10 Paliwa stale: biomasa stala - biopaliwo stale Solid fuels: solid biomass - solid biofuel Zawartosc siarki calkowitej Zakres: (0,03 – 5,00) %m/m Metoda wysokotemperaturowego spalania z detekcja IR Total sulfur content Range: (0,03 – 5,00) %m/m High temp. combustion method with IR detection PN-EN ISO 16994:2016-10","categories":["petro"],"row_index":425,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid biomass - solid biofuel Total sulfur content Range: (0,03 – 5,00) %m/m High temp. combustion method with IR detection PN-EN ISO 16994:2016-10","search_zh":"固体燃料：固体生物质 － 固体生物燃料 Solid fuels: solid biomass - solid biofuel PN-EN ISO 16994:2016-10","test_object_zh":"固体燃料：固体生物质 － 固体生物燃料 Solid fuels: solid biomass - solid biofuel"},{"_id":"6a5a55ef9af9f73f38250c46","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Materiały budowlane: - kruszywa mineralne Grunty Gleba Paliwa stałe: - paliwo wtórne – paliwo alternatywne - węgiel kamienny - biomasa stała - biopaliwo stałe OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 09, 19 12 10, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych","test_object_en":"Building materials: - mineral aggregates Grounds Soil Solid fuels: - secondary fuel – alternative fuel - hard coal - solid biomass - solid biofuel WasteO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 09, 19 12 10, 19 13 06 Slag, bottom ash and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste","methodology":"Zawartość tlenków Zakres: SiO (0,505 – 90,36) %m/m 2 Al O (0,042 – 54,50) %m/m 2 3 Fe O (0,015 – 14,67) %m/m 2 3 CaO (0,018 – 61,87) %m/m MgO (0,012 – 18,00) %m/m Na O (0,007 – 3,86) %m/m 2 K O (0,009 – 3,07) %m/m 2 SO (0,010 – 5,80) %m/m 3 TiO (0,002 – 2,64) %m/m 2 P O (0,008 – 2,69) %m/m 2 5 Metoda spektrometrii fluorescencji rentgenowskiej z dyspersją długości fali (WD-XRF)","methodology_en":"Oxides content Range: SiO (0,505 – 90,36) %m/m 2 Al O (0,042 – 54,50) %m/m 2 3 Fe O (0,015 – 14,67) %m/m 2 3 CaO (0,018 – 61,87) %m/m MgO (0,012 – 18,00) %m/m Na O (0,007 – 3,86) %m/m 2 K O (0,009 – 3,07) %m/m 2 SO (0,010 – 5,80) %m/m 3 TiO (0,002 – 2,64) %m/m 2 P O (0,008 – 2,69) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry (WD-XRF) method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość tlenków Zakres: SiO (0,505 – 90,36) %m/m 2 Al O (0,042 – 54,50) %m/m 2 3 Fe O (0,015 – 14,67) %m/m 2 3 CaO (0,018 – 61,87) %m/m MgO (0,012 – 18,00) %m/m Na O (0,007 – 3,86) %m/m 2 K O (0,009 – 3,07) %m/m 2 SO (0,010 – 5,80) %m/m 3 TiO (0,002 – 2,64) %m/m 2 P O (0,008 – 2,69) %m/m 2 5 Metoda spektrometrii fluorescencji rentgenowskiej z dyspersją długości fali (WD-XRF)","reference":"ISO/TS 16996:2015(E) ISO 18227:2014(E) PN-EN 15309:2010","norm_bases":["ISO/TS 16996:2015(E) ISO 18227:2014(E) PN-EN 15309:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały budowlane: - kruszywa mineralne Grunty Gleba Paliwa stałe: - paliwo wtórne – paliwo alternatywne - węgiel kamienny - biomasa stała - biopaliwo stałe OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 09, 19 12 10, 19 13 06 Żużle, popioły paleniskowe i pyły z kotłów, popioły lotne z węgla, stałe odpady z wapniowych metod odsiarczania gazów odlotowych, piaski ze złóż fluidalnych, mieszaniny popiołów lotnych i odpadów stałych z wapniowych metod odsiarczania gazów odlotowych, mieszanki popiołowo-żużlowe z mokrego odprowadzania odpadów paleniskowych Zawartość tlenków Zakres: SiO (0,505 – 90,36) %m/m 2 Al O (0,042 – 54,50) %m/m 2 3 Fe O (0,015 – 14,67) %m/m 2 3 CaO (0,018 – 61,87) %m/m MgO (0,012 – 18,00) %m/m Na O (0,007 – 3,86) %m/m 2 K O (0,009 – 3,07) %m/m 2 SO (0,010 – 5,80) %m/m 3 TiO (0,002 – 2,64) %m/m 2 P O (0,008 – 2,69) %m/m 2 5 Metoda spektrometrii fluorescencji rentgenowskiej z dyspersją długości fali (WD-XRF) ISO/TS 16996:2015(E) ISO 18227:2014(E) PN-EN 15309:2010 Materialy budowlane: - kruszywa mineralne Grunty Gleba Paliwa stale: - paliwo wtorne – paliwo alternatywne - wegiel kamienny - biomasa stala - biopaliwo stale OdpadyO): kod 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 09, 19 12 10, 19 13 06 Zuzle, popioly paleniskowe i pyly z kotlow, popioly lotne z wegla, stale odpady z wapniowych metod odsiarczania gazow odlotowych, piaski ze zloz fluidalnych, mieszaniny popiolow lotnych i odpadow stalych z wapniowych metod odsiarczania gazow odlotowych, mieszanki popiolowo-zuzlowe z mokrego odprowadzania odpadow paleniskowych Zawartosc tlenkow Zakres: SiO (0,505 – 90,36) %m/m 2 Al O (0,042 – 54,50) %m/m 2 3 Fe O (0,015 – 14,67) %m/m 2 3 CaO (0,018 – 61,87) %m/m MgO (0,012 – 18,00) %m/m Na O (0,007 – 3,86) %m/m 2 K O (0,009 – 3,07) %m/m 2 SO (0,010 – 5,80) %m/m 3 TiO (0,002 – 2,64) %m/m 2 P O (0,008 – 2,69) %m/m 2 5 Metoda spektrometrii fluorescencji rentgenowskiej z dyspersja dlugosci fali (WD-XRF) ISO/TS 16996:2015(E) ISO 18227:2014(E) PN-EN 15309:2010","categories":["environment","petro","materials","construction"],"row_index":426,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building materials: - mineral aggregates Grounds Soil Solid fuels: - secondary fuel – alternative fuel - hard coal - solid biomass - solid biofuel WasteO): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 09, 19 12 10, 19 13 06 Slag, bottom ash and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Oxides content Range: SiO (0,505 – 90,36) %m/m 2 Al O (0,042 – 54,50) %m/m 2 3 Fe O (0,015 – 14,67) %m/m 2 3 CaO (0,018 – 61,87) %m/m MgO (0,012 – 18,00) %m/m Na O (0,007 – 3,86) %m/m 2 K O (0,009 – 3,07) %m/m 2 SO (0,010 – 5,80) %m/m 3 TiO (0,002 – 2,64) %m/m 2 P O (0,008 – 2,69) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry (WD-XRF) method ISO/TS 16996:2015(E) ISO 18227:2014(E) PN-EN 15309:2010"},{"_id":"6a5a55ef9af9f73f38250c47","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Building materials: mineral aggregates Soils Grounds Solid fuels: solid recovered fuels - refuse derived fuel, - coal - solid biomass - solid biofuel Solid waste O): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 09, 19 12 10, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste","test_object_en":"Building materials: mineral aggregates Soils Grounds Solid fuels: solid recovered fuels - refuse derived fuel, - coal - solid biomass - solid biofuel Solid waste O): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 09, 19 12 10, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste","methodology":"Oxides content Range: SiO (0,505 – 90,36) %m/m 2 Al O (0,042 – 54,50) %m/m 2 3 Fe O (0,015 – 14,67) %m/m 2 3 CaO (0,018 – 61,87) %m/m MgO (0,012 – 18,00) %m/m Na O (0,007 – 3,86) %m/m 2 K O (0,009 – 3,07) %m/m 2 SO (0,010 – 5,80) %m/m 3 TiO (0,002 – 2,64) %m/m 2 P O (0,008 – 2,69) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","methodology_en":"Oxides content Range: SiO (0,505 – 90,36) %m/m 2 Al O (0,042 – 54,50) %m/m 2 3 Fe O (0,015 – 14,67) %m/m 2 3 CaO (0,018 – 61,87) %m/m MgO (0,012 – 18,00) %m/m Na O (0,007 – 3,86) %m/m 2 K O (0,009 – 3,07) %m/m 2 SO (0,010 – 5,80) %m/m 3 TiO (0,002 – 2,64) %m/m 2 P O (0,008 – 2,69) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Oxides content Range: SiO (0,505 – 90,36) %m/m 2 Al O (0,042 – 54,50) %m/m 2 3 Fe O (0,015 – 14,67) %m/m 2 3 CaO (0,018 – 61,87) %m/m MgO (0,012 – 18,00) %m/m Na O (0,007 – 3,86) %m/m 2 K O (0,009 – 3,07) %m/m 2 SO (0,010 – 5,80) %m/m 3 TiO (0,002 – 2,64) %m/m 2 P O (0,008 – 2,69) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","reference":"ISO/TS 16996:2015(E) ISO 18227:2014(E) PN-EN 15309:2010","norm_bases":["ISO/TS 16996:2015(E) ISO 18227:2014(E) PN-EN 15309:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Building materials: mineral aggregates Soils Grounds Solid fuels: solid recovered fuels - refuse derived fuel, - coal - solid biomass - solid biofuel Solid waste O): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 09, 19 12 10, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Oxides content Range: SiO (0,505 – 90,36) %m/m 2 Al O (0,042 – 54,50) %m/m 2 3 Fe O (0,015 – 14,67) %m/m 2 3 CaO (0,018 – 61,87) %m/m MgO (0,012 – 18,00) %m/m Na O (0,007 – 3,86) %m/m 2 K O (0,009 – 3,07) %m/m 2 SO (0,010 – 5,80) %m/m 3 TiO (0,002 – 2,64) %m/m 2 P O (0,008 – 2,69) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) ISO/TS 16996:2015(E) ISO 18227:2014(E) PN-EN 15309:2010 Building materials: mineral aggregates Soils Grounds Solid fuels: solid recovered fuels - refuse derived fuel, - coal - solid biomass - solid biofuel Solid waste O): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 09, 19 12 10, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Oxides content Range: SiO (0,505 – 90,36) %m/m 2 Al O (0,042 – 54,50) %m/m 2 3 Fe O (0,015 – 14,67) %m/m 2 3 CaO (0,018 – 61,87) %m/m MgO (0,012 – 18,00) %m/m Na O (0,007 – 3,86) %m/m 2 K O (0,009 – 3,07) %m/m 2 SO (0,010 – 5,80) %m/m 3 TiO (0,002 – 2,64) %m/m 2 P O (0,008 – 2,69) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) ISO/TS 16996:2015(E) ISO 18227:2014(E) PN-EN 15309:2010","categories":["materials","environment","petro","construction"],"row_index":427,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Building materials: mineral aggregates Soils Grounds Solid fuels: solid recovered fuels - refuse derived fuel, - coal - solid biomass - solid biofuel Solid waste O): code 01 01 02, 01 03 06, 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 82, 10 09 08, 17 01 01, 17 01 02, 17 01 81, 17 05 04, 17 05 08, 17 09 04, 19 01 12, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 09 01, 19 09 02, 19 12 01, 19 12 04, 19 12 06, 19 12 07, 19 12 08, 19 12 09, 19 12 10, 19 13 06 Slag, bottom ash, and boiler dust, coal fly ash, solid waste from lime-based flue gas desulfurization methods, sands from fluidized beds, mixtures of fly ash and solid waste from lime-based flue gas desulfurization methods, ash-slag mixtures from wet discharge of combustion waste Oxides content Range: SiO (0,505 – 90,36) %m/m 2 Al O (0,042 – 54,50) %m/m 2 3 Fe O (0,015 – 14,67) %m/m 2 3 CaO (0,018 – 61,87) %m/m MgO (0,012 – 18,00) %m/m Na O (0,007 – 3,86) %m/m 2 K O (0,009 – 3,07) %m/m 2 SO (0,010 – 5,80) %m/m 3 TiO (0,002 – 2,64) %m/m 2 P O (0,008 – 2,69) %m/m 2 5 Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) ISO/TS 16996:2015(E) ISO 18227:2014(E) PN-EN 15309:2010"},{"_id":"6a5a55ef9af9f73f38250c48","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, Sewage","test_object_en":"Water, Sewage","methodology":"Stężenie polichlorowanych bifenyli (PCB) Zakres: PCB 28 (0,10 – 2,0) µg/l PCB 52 (0,10 – 2,0) µg/l PCB 101 (0,10 – 2,0) µg/l PCB 118 (0,10 – 2,0) µg/l PCB 138 (0,10 – 2,0) µg/l PCB 153 (0,10 – 2,0) µg/l PCB 180 (0,10 – 2,0) µg/l Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) Polychlorinated biphenyls concentration (PCB) Range: PCB 28 (0,10 – 2,0) µg/l PCB 52 (0,10 – 2,0) µg/l PCB 101 (0,10 – 2,0) µg/l PCB 118 (0,10 – 2,0) µg/l PCB 138 (0,10 – 2,0) µg/l PCB 153 (0,10 – 2,0) µg/l PCB 180 (0,10 – 2,0) µg/l Gas chromatography method with electron capture detection (GC-ECD)","methodology_en":"Polychlorinated biphenyls concentration (PCB) Range: PCB 28 (0,10 – 2,0) µg/l PCB 52 (0,10 – 2,0) µg/l PCB 101 (0,10 – 2,0) µg/l PCB 118 (0,10 – 2,0) µg/l PCB 138 (0,10 – 2,0) µg/l PCB 153 (0,10 – 2,0) µg/l PCB 180 (0,10 – 2,0) µg/l Gas chromatography method with electron capture detection (GC-ECD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie polichlorowanych bifenyli (PCB) Zakres: PCB 28 (0,10 – 2,0) µg/l PCB 52 (0,10 – 2,0) µg/l PCB 101 (0,10 – 2,0) µg/l PCB 118 (0,10 – 2,0) µg/l PCB 138 (0,10 – 2,0) µg/l PCB 153 (0,10 – 2,0) µg/l PCB 180 (0,10 – 2,0) µg/l Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) Polychlorinated biphenyls concentration (PCB) Range: PCB 28 (0,10 – 2,0) µg/l PCB 52 (0,10 – 2,0) µg/l PCB 101 (0,10 – 2,0) µg/l PCB 118 (0,10 – 2,0) µg/l PCB 138 (0,10 – 2,0) µg/l PCB 153 (0,10 – 2,0) µg/l PCB 180 (0,10 – 2,0) µg/l Gas chromatography method with electron capture detection (GC-ECD)","reference":"PN-EN ISO 6468:2002","norm_bases":["PN-EN ISO 6468:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, Sewage Stężenie polichlorowanych bifenyli (PCB) Zakres: PCB 28 (0,10 – 2,0) µg/l PCB 52 (0,10 – 2,0) µg/l PCB 101 (0,10 – 2,0) µg/l PCB 118 (0,10 – 2,0) µg/l PCB 138 (0,10 – 2,0) µg/l PCB 153 (0,10 – 2,0) µg/l PCB 180 (0,10 – 2,0) µg/l Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) Polychlorinated biphenyls concentration (PCB) Range: PCB 28 (0,10 – 2,0) µg/l PCB 52 (0,10 – 2,0) µg/l PCB 101 (0,10 – 2,0) µg/l PCB 118 (0,10 – 2,0) µg/l PCB 138 (0,10 – 2,0) µg/l PCB 153 (0,10 – 2,0) µg/l PCB 180 (0,10 – 2,0) µg/l Gas chromatography method with electron capture detection (GC-ECD) PN-EN ISO 6468:2002 Woda, scieki Water, Sewage Stezenie polichlorowanych bifenyli (PCB) Zakres: PCB 28 (0,10 – 2,0) µg/l PCB 52 (0,10 – 2,0) µg/l PCB 101 (0,10 – 2,0) µg/l PCB 118 (0,10 – 2,0) µg/l PCB 138 (0,10 – 2,0) µg/l PCB 153 (0,10 – 2,0) µg/l PCB 180 (0,10 – 2,0) µg/l Metoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) Polychlorinated biphenyls concentration (PCB) Range: PCB 28 (0,10 – 2,0) µg/l PCB 52 (0,10 – 2,0) µg/l PCB 101 (0,10 – 2,0) µg/l PCB 118 (0,10 – 2,0) µg/l PCB 138 (0,10 – 2,0) µg/l PCB 153 (0,10 – 2,0) µg/l PCB 180 (0,10 – 2,0) µg/l Gas chromatography method with electron capture detection (GC-ECD) PN-EN ISO 6468:2002","categories":["water"],"row_index":428,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, Sewage Polychlorinated biphenyls concentration (PCB) Range: PCB 28 (0,10 – 2,0) µg/l PCB 52 (0,10 – 2,0) µg/l PCB 101 (0,10 – 2,0) µg/l PCB 118 (0,10 – 2,0) µg/l PCB 138 (0,10 – 2,0) µg/l PCB 153 (0,10 – 2,0) µg/l PCB 180 (0,10 – 2,0) µg/l Gas chromatography method with electron capture detection (GC-ECD) PN-EN ISO 6468:2002","search_zh":"水、废水 PN-EN ISO 6468:2002","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250c49","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, Sewage","test_object_en":"Water, Sewage","methodology":"Suma polichlorowanych bifenyli (PCB) (z obliczeń) Sum of polychlorinated biphenyls (PCBs) (from calculations)","methodology_en":"Sum of polychlorinated biphenyls (PCBs) (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma polichlorowanych bifenyli (PCB) (z obliczeń) Sum of polychlorinated biphenyls (PCBs) (from calculations)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, Sewage Suma polichlorowanych bifenyli (PCB) (z obliczeń) Sum of polychlorinated biphenyls (PCBs) (from calculations) Woda, scieki Water, Sewage Suma polichlorowanych bifenyli (PCB) (z obliczen) Sum of polychlorinated biphenyls (PCBs) (from calculations)","categories":["water"],"row_index":429,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, Sewage Sum of polychlorinated biphenyls (PCBs) (from calculations)","search_zh":"水、废水","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250c4a","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, Sewage","test_object_en":"Water, Sewage","methodology":"Indeks oleju mineralnego Zakres: (0,10 – 50) mg/l Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Mineral oil index Range: (0,10 – 50) mg/l Gas chromatography method with flame ionization detection (GC-FID)","methodology_en":"Mineral oil index Range: (0,10 – 50) mg/l Gas chromatography method with flame ionization detection (GC-FID)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indeks oleju mineralnego Zakres: (0,10 – 50) mg/l Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Mineral oil index Range: (0,10 – 50) mg/l Gas chromatography method with flame ionization detection (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, Sewage Indeks oleju mineralnego Zakres: (0,10 – 50) mg/l Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Mineral oil index Range: (0,10 – 50) mg/l Gas chromatography method with flame ionization detection (GC-FID) PN-EN ISO 9377-2:2003 Woda, scieki Water, Sewage Indeks oleju mineralnego Zakres: (0,10 – 50) mg/l Metoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Mineral oil index Range: (0,10 – 50) mg/l Gas chromatography method with flame ionization detection (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":430,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, Sewage Mineral oil index Range: (0,10 – 50) mg/l Gas chromatography method with flame ionization detection (GC-FID) PN-EN ISO 9377-2:2003","search_zh":"水、废水 PN-EN ISO 9377-2:2003","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250c4b","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, Sewage","test_object_en":"Water, Sewage","methodology":"Stężenie lotnych chlorowcowych pochodnych węglowodorów Zakres: trichlorometan (chloroform) (0,40 – 100) μg/l bromodichlorometan (0,40 – 100) μg/l chlorodibromometan (0,40 – 100) μg/l tribromometan (bromoform) (0,40 – 100) μg/l","methodology_en":"Concentration of volatile halogenated hydrocarbon derivatives Range: trichloromethane (chloroform) (0,40 – 100) μg/l bromodichloromethane (0,40 – 100) μg/l chlorodibromomethane (0,40 – 100) μg/l tribromomethane (bromoform) (0,40 – 100) μg/l","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie lotnych chlorowcowych pochodnych węglowodorów Zakres: trichlorometan (chloroform) (0,40 – 100) μg/l bromodichlorometan (0,40 – 100) μg/l chlorodibromometan (0,40 – 100) μg/l tribromometan (bromoform) (0,40 – 100) μg/l","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, Sewage Stężenie lotnych chlorowcowych pochodnych węglowodorów Zakres: trichlorometan (chloroform) (0,40 – 100) μg/l bromodichlorometan (0,40 – 100) μg/l chlorodibromometan (0,40 – 100) μg/l tribromometan (bromoform) (0,40 – 100) μg/l PN-EN ISO 10301:2002 Woda, scieki Water, Sewage Stezenie lotnych chlorowcowych pochodnych weglowodorow Zakres: trichlorometan (chloroform) (0,40 – 100) μg/l bromodichlorometan (0,40 – 100) μg/l chlorodibromometan (0,40 – 100) μg/l tribromometan (bromoform) (0,40 – 100) μg/l PN-EN ISO 10301:2002","categories":["water"],"row_index":431,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, Sewage Concentration of volatile halogenated hydrocarbon derivatives Range: trichloromethane (chloroform) (0,40 – 100) μg/l bromodichloromethane (0,40 – 100) μg/l chlorodibromomethane (0,40 – 100) μg/l tribromomethane (bromoform) (0,40 – 100) μg/l PN-EN ISO 10301:2002","search_zh":"水、废水 PN-EN ISO 10301:2002","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250c4c","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, Sewage","test_object_en":"Water, Sewage","methodology":"tetrachlorometan (czterochlorek węgla, tetrachlorek węgla) (0,40 – 100) μg/l trichloroeten (trichloroetylen, TRI) (0,40 – 100) μg/l tetrachloroeten (tetrachloroetylen, nadchloroetylen, PER) (0,40 – 100) μg/l Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) Volatile halogenated hydrocarbons concentration Range: trichloromethane (chloroform), (0,40 – 100) μg/l bromodichloromethane, (0,40 – 100) μg/l chlorodibromomethane, (0,40 – 100) μg/l tribromomethane (bromoform), (0,40 – 100) μg/l tetrachloromethane (carbon tetrachhloride), (0,40 – 100) μg/l trichloroethene (trichloroethylene, TRI), (0,40 – 100) μg/l tetrachloroethene (tetrachloroethylene, nadchloroetylen,PER) (0,40 – 100) μg/l Gas chromatography method with electron capture detection (GC-ECD)","methodology_en":"Volatile halogenated hydrocarbons concentration Range: trichloromethane (chloroform), (0,40 – 100) μg/l bromodichloromethane, (0,40 – 100) μg/l chlorodibromomethane, (0,40 – 100) μg/l tribromomethane (bromoform), (0,40 – 100) μg/l tetrachloromethane (carbon tetrachhloride), (0,40 – 100) μg/l trichloroethene (trichloroethylene, TRI), (0,40 – 100) μg/l tetrachloroethene (tetrachloroethylene, nadchloroetylen,PER) (0,40 – 100) μg/l Gas chromatography method with electron capture detection (GC-ECD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"tetrachlorometan (czterochlorek węgla, tetrachlorek węgla) (0,40 – 100) μg/l trichloroeten (trichloroetylen, TRI) (0,40 – 100) μg/l tetrachloroeten (tetrachloroetylen, nadchloroetylen, PER) (0,40 – 100) μg/l Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) Volatile halogenated hydrocarbons concentration Range: trichloromethane (chloroform), (0,40 – 100) μg/l bromodichloromethane, (0,40 – 100) μg/l chlorodibromomethane, (0,40 – 100) μg/l tribromomethane (bromoform), (0,40 – 100) μg/l tetrachloromethane (carbon tetrachhloride), (0,40 – 100) μg/l trichloroethene (trichloroethylene, TRI), (0,40 – 100) μg/l tetrachloroethene (tetrachloroethylene, nadchloroetylen,PER) (0,40 – 100) μg/l Gas chromatography method with electron capture detection (GC-ECD)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, Sewage tetrachlorometan (czterochlorek węgla, tetrachlorek węgla) (0,40 – 100) μg/l trichloroeten (trichloroetylen, TRI) (0,40 – 100) μg/l tetrachloroeten (tetrachloroetylen, nadchloroetylen, PER) (0,40 – 100) μg/l Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) Volatile halogenated hydrocarbons concentration Range: trichloromethane (chloroform), (0,40 – 100) μg/l bromodichloromethane, (0,40 – 100) μg/l chlorodibromomethane, (0,40 – 100) μg/l tribromomethane (bromoform), (0,40 – 100) μg/l tetrachloromethane (carbon tetrachhloride), (0,40 – 100) μg/l trichloroethene (trichloroethylene, TRI), (0,40 – 100) μg/l tetrachloroethene (tetrachloroethylene, nadchloroetylen,PER) (0,40 – 100) μg/l Gas chromatography method with electron capture detection (GC-ECD) PN-EN ISO 10301:2002 Woda, scieki Water, Sewage tetrachlorometan (czterochlorek wegla, tetrachlorek wegla) (0,40 – 100) μg/l trichloroeten (trichloroetylen, TRI) (0,40 – 100) μg/l tetrachloroeten (tetrachloroetylen, nadchloroetylen, PER) (0,40 – 100) μg/l Metoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) Volatile halogenated hydrocarbons concentration Range: trichloromethane (chloroform), (0,40 – 100) μg/l bromodichloromethane, (0,40 – 100) μg/l chlorodibromomethane, (0,40 – 100) μg/l tribromomethane (bromoform), (0,40 – 100) μg/l tetrachloromethane (carbon tetrachhloride), (0,40 – 100) μg/l trichloroethene (trichloroethylene, TRI), (0,40 – 100) μg/l tetrachloroethene (tetrachloroethylene, nadchloroetylen,PER) (0,40 – 100) μg/l Gas chromatography method with electron capture detection (GC-ECD) PN-EN ISO 10301:2002","categories":["water"],"row_index":432,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, Sewage Volatile halogenated hydrocarbons concentration Range: trichloromethane (chloroform), (0,40 – 100) μg/l bromodichloromethane, (0,40 – 100) μg/l chlorodibromomethane, (0,40 – 100) μg/l tribromomethane (bromoform), (0,40 – 100) μg/l tetrachloromethane (carbon tetrachhloride), (0,40 – 100) μg/l trichloroethene (trichloroethylene, TRI), (0,40 – 100) μg/l tetrachloroethene (tetrachloroethylene, nadchloroetylen,PER) (0,40 – 100) μg/l Gas chromatography method with electron capture detection (GC-ECD) PN-EN ISO 10301:2002","search_zh":"水、废水 PN-EN ISO 10301:2002","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250c4d","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, Sewage","test_object_en":"Water, Sewage","methodology":"Suma lotnych chlorowcowych pochodnych węglowodorów (z obliczeń) Sum of volatile halogenated hydrocarbons (from calculations)","methodology_en":"Sum of volatile halogenated hydrocarbons (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma lotnych chlorowcowych pochodnych węglowodorów (z obliczeń) Sum of volatile halogenated hydrocarbons (from calculations)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, Sewage Suma lotnych chlorowcowych pochodnych węglowodorów (z obliczeń) Sum of volatile halogenated hydrocarbons (from calculations) Woda, scieki Water, Sewage Suma lotnych chlorowcowych pochodnych weglowodorow (z obliczen) Sum of volatile halogenated hydrocarbons (from calculations)","categories":["water"],"row_index":433,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, Sewage Sum of volatile halogenated hydrocarbons (from calculations)","search_zh":"水、废水","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250c4e","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, Sewage","test_object_en":"Water, Sewage","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA) Zakres: naftalen (0,050 – 10) μg/l acenaften (0,050 – 10) μg/l fluoren (0,050 – 10) μg/l fenantren (0,050 – 10) μg/l antracen (0,050 – 10) μg/l fluoranten (0,050 – 10) μg/l piren (0,050 – 10) μg/l benzo(a)antracen (0,050 – 10) μg/l chryzen (0,050 – 10) μg/l benzo(b)fluoranten (0,050 – 10) μg/l benzo(k)fluoranten (0,050 – 10) μg/l benzo(a)piren (0,050 – 10) μg/l benzo(g,h,i)perylen (0,050 – 10) μg/l indeno(1,2,3-cd)piren (0,050 – 10) μg/l dibenzo(a,h)antracen (0,050 – 10) μg/l Metoda wysokosprawnej chromatografii cieczowej z detekcją fluoroscencyjną (HPLC-FLD) Polycyclic aromatic hydrocarbons concentration (PAHs) Range: naphthalene (0,050 – 10) μg/l acenaphtene (0,050 – 10) μg/l fluorene (0,050 – 10) μg/l phenanthrene (0,050 – 10) μg/l anthracene (0,050 – 10) μg/l fluoranthene (0,050 – 10) μg/l pyrene (0,050 – 10) μg/l benzo(a)anthracene (0,050 – 10) μg/l chrysene (0,050 – 10) μg/l benzo(b)fluoranthene (0,050 – 10) μg/l benzo(k)fluoranthene (0,050 – 10) μg/l benzo(a)pyrene (0,050 – 10) μg/l benzo(g,h,i)perylene (0,050 – 10) μg/l indeno(1,2,3-cd)pyrene (0,050 – 10) μg/l dibenzo(a,h)anthracene (0,050 – 10) μg/l High-performance liquid chromatography methopd with fluorescence detection (HPLC-FLD)","methodology_en":"Polycyclic aromatic hydrocarbons concentration (PAHs) Range: naphthalene (0,050 – 10) μg/l acenaphtene (0,050 – 10) μg/l fluorene (0,050 – 10) μg/l phenanthrene (0,050 – 10) μg/l anthracene (0,050 – 10) μg/l fluoranthene (0,050 – 10) μg/l pyrene (0,050 – 10) μg/l benzo(a)anthracene (0,050 – 10) μg/l chrysene (0,050 – 10) μg/l benzo(b)fluoranthene (0,050 – 10) μg/l benzo(k)fluoranthene (0,050 – 10) μg/l benzo(a)pyrene (0,050 – 10) μg/l benzo(g,h,i)perylene (0,050 – 10) μg/l indeno(1,2,3-cd)pyrene (0,050 – 10) μg/l dibenzo(a,h)anthracene (0,050 – 10) μg/l High-performance liquid chromatography methopd with fluorescence detection (HPLC-FLD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA) Zakres: naftalen (0,050 – 10) μg/l acenaften (0,050 – 10) μg/l fluoren (0,050 – 10) μg/l fenantren (0,050 – 10) μg/l antracen (0,050 – 10) μg/l fluoranten (0,050 – 10) μg/l piren (0,050 – 10) μg/l benzo(a)antracen (0,050 – 10) μg/l chryzen (0,050 – 10) μg/l benzo(b)fluoranten (0,050 – 10) μg/l benzo(k)fluoranten (0,050 – 10) μg/l benzo(a)piren (0,050 – 10) μg/l benzo(g,h,i)perylen (0,050 – 10) μg/l indeno(1,2,3-cd)piren (0,050 – 10) μg/l dibenzo(a,h)antracen (0,050 – 10) μg/l Metoda wysokosprawnej chromatografii cieczowej z detekcją fluoroscencyjną (HPLC-FLD) Polycyclic aromatic hydrocarbons concentration (PAHs) Range: naphthalene (0,050 – 10) μg/l acenaphtene (0,050 – 10) μg/l fluorene (0,050 – 10) μg/l phenanthrene (0,050 – 10) μg/l anthracene (0,050 – 10) μg/l fluoranthene (0,050 – 10) μg/l pyrene (0,050 – 10) μg/l benzo(a)anthracene (0,050 – 10) μg/l chrysene (0,050 – 10) μg/l benzo(b)fluoranthene (0,050 – 10) μg/l benzo(k)fluoranthene (0,050 – 10) μg/l benzo(a)pyrene (0,050 – 10) μg/l benzo(g,h,i)perylene (0,050 – 10) μg/l indeno(1,2,3-cd)pyrene (0,050 – 10) μg/l dibenzo(a,h)anthracene (0,050 – 10) μg/l High-performance liquid chromatography methopd with fluorescence detection (HPLC-FLD)","reference":"PN-EN ISO 17993:2005 z wyłączeniem pkt 8.1-8.4 SO-4/ZLGIG/WYK-07 ed. 1 z dn. 01.08.2025 PN-EN ISO 17993:2005 excluding pt 8.1-8.4 SO-4/ZLGIG/WYK-07 ed. 1st of 01/08/2025","norm_bases":["PN-EN ISO 17993:2005 z wyłączeniem pkt 8.1-8.4 SO-4/ZLGIG/WYK-07 ed. 1 z dn. 01.08.2025 PN-EN ISO 17993:2005 excluding pt 8.1-8.4 SO-4/ZLGIG/WYK-07 ed. 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, Sewage Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA) Zakres: naftalen (0,050 – 10) μg/l acenaften (0,050 – 10) μg/l fluoren (0,050 – 10) μg/l fenantren (0,050 – 10) μg/l antracen (0,050 – 10) μg/l fluoranten (0,050 – 10) μg/l piren (0,050 – 10) μg/l benzo(a)antracen (0,050 – 10) μg/l chryzen (0,050 – 10) μg/l benzo(b)fluoranten (0,050 – 10) μg/l benzo(k)fluoranten (0,050 – 10) μg/l benzo(a)piren (0,050 – 10) μg/l benzo(g,h,i)perylen (0,050 – 10) μg/l indeno(1,2,3-cd)piren (0,050 – 10) μg/l dibenzo(a,h)antracen (0,050 – 10) μg/l Metoda wysokosprawnej chromatografii cieczowej z detekcją fluoroscencyjną (HPLC-FLD) Polycyclic aromatic hydrocarbons concentration (PAHs) Range: naphthalene (0,050 – 10) μg/l acenaphtene (0,050 – 10) μg/l fluorene (0,050 – 10) μg/l phenanthrene (0,050 – 10) μg/l anthracene (0,050 – 10) μg/l fluoranthene (0,050 – 10) μg/l pyrene (0,050 – 10) μg/l benzo(a)anthracene (0,050 – 10) μg/l chrysene (0,050 – 10) μg/l benzo(b)fluoranthene (0,050 – 10) μg/l benzo(k)fluoranthene (0,050 – 10) μg/l benzo(a)pyrene (0,050 – 10) μg/l benzo(g,h,i)perylene (0,050 – 10) μg/l indeno(1,2,3-cd)pyrene (0,050 – 10) μg/l dibenzo(a,h)anthracene (0,050 – 10) μg/l High-performance liquid chromatography methopd with fluorescence detection (HPLC-FLD) PN-EN ISO 17993:2005 z wyłączeniem pkt 8.1-8.4 SO-4/ZLGIG/WYK-07 ed. 1 z dn. 01.08.2025 PN-EN ISO 17993:2005 excluding pt 8.1-8.4 SO-4/ZLGIG/WYK-07 ed. 1st of 01/08/2025 Woda, scieki Water, Sewage Stezenie wielopierscieniowych weglowodorow aromatycznych (WWA) Zakres: naftalen (0,050 – 10) μg/l acenaften (0,050 – 10) μg/l fluoren (0,050 – 10) μg/l fenantren (0,050 – 10) μg/l antracen (0,050 – 10) μg/l fluoranten (0,050 – 10) μg/l piren (0,050 – 10) μg/l benzo(a)antracen (0,050 – 10) μg/l chryzen (0,050 – 10) μg/l benzo(b)fluoranten (0,050 – 10) μg/l benzo(k)fluoranten (0,050 – 10) μg/l benzo(a)piren (0,050 – 10) μg/l benzo(g,h,i)perylen (0,050 – 10) μg/l indeno(1,2,3-cd)piren (0,050 – 10) μg/l dibenzo(a,h)antracen (0,050 – 10) μg/l Metoda wysokosprawnej chromatografii cieczowej z detekcja fluoroscencyjna (HPLC-FLD) Polycyclic aromatic hydrocarbons concentration (PAHs) Range: naphthalene (0,050 – 10) μg/l acenaphtene (0,050 – 10) μg/l fluorene (0,050 – 10) μg/l phenanthrene (0,050 – 10) μg/l anthracene (0,050 – 10) μg/l fluoranthene (0,050 – 10) μg/l pyrene (0,050 – 10) μg/l benzo(a)anthracene (0,050 – 10) μg/l chrysene (0,050 – 10) μg/l benzo(b)fluoranthene (0,050 – 10) μg/l benzo(k)fluoranthene (0,050 – 10) μg/l benzo(a)pyrene (0,050 – 10) μg/l benzo(g,h,i)perylene (0,050 – 10) μg/l indeno(1,2,3-cd)pyrene (0,050 – 10) μg/l dibenzo(a,h)anthracene (0,050 – 10) μg/l High-performance liquid chromatography methopd with fluorescence detection (HPLC-FLD) PN-EN ISO 17993:2005 z wylaczeniem pkt 8.1-8.4 SO-4/ZLGIG/WYK-07 ed. 1 z dn. 01.08.2025 PN-EN ISO 17993:2005 excluding pt 8.1-8.4 SO-4/ZLGIG/WYK-07 ed. 1st of 01/08/2025","categories":["water"],"row_index":434,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, Sewage Polycyclic aromatic hydrocarbons concentration (PAHs) Range: naphthalene (0,050 – 10) μg/l acenaphtene (0,050 – 10) μg/l fluorene (0,050 – 10) μg/l phenanthrene (0,050 – 10) μg/l anthracene (0,050 – 10) μg/l fluoranthene (0,050 – 10) μg/l pyrene (0,050 – 10) μg/l benzo(a)anthracene (0,050 – 10) μg/l chrysene (0,050 – 10) μg/l benzo(b)fluoranthene (0,050 – 10) μg/l benzo(k)fluoranthene (0,050 – 10) μg/l benzo(a)pyrene (0,050 – 10) μg/l benzo(g,h,i)perylene (0,050 – 10) μg/l indeno(1,2,3-cd)pyrene (0,050 – 10) μg/l dibenzo(a,h)anthracene (0,050 – 10) μg/l High-performance liquid chromatography methopd with fluorescence detection (HPLC-FLD) PN-EN ISO 17993:2005 z wyłączeniem pkt 8.1-8.4 SO-4/ZLGIG/WYK-07 ed. 1 z dn. 01.08.2025 PN-EN ISO 17993:2005 excluding pt 8.1-8.4 SO-4/ZLGIG/WYK-07 ed. 1st of 01/08/2025","search_zh":"水、废水 PN-EN ISO 17993:2005 z wyłączeniem pkt 8.1-8.4 SO-4/ZLGIG/WYK-07 ed. 1 z dn. 01.08.2025 PN-EN ISO 17993:2005 excluding pt 8.1-8.4 SO-4/ZLGIG/WYK-07 ed. 1st of 01/08/2025","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250c4f","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, Sewage","test_object_en":"Water, Sewage","methodology":"Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń) Sum of polycyclic aromatic hydrocarbons (PAH) (from calculations)","methodology_en":"Sum of polycyclic aromatic hydrocarbons (PAH) (calculated) Sum of polycyclic aromatic hydrocarbons (PAH) (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń) Sum of polycyclic aromatic hydrocarbons (PAH) (from calculations)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, Sewage Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń) Sum of polycyclic aromatic hydrocarbons (PAH) (from calculations) Woda, scieki Water, Sewage Suma wielopierscieniowych weglowodorow aromatycznych (WWA) (z obliczen) Sum of polycyclic aromatic hydrocarbons (PAH) (from calculations)","categories":["water"],"row_index":435,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, Sewage Sum of polycyclic aromatic hydrocarbons (PAH) (calculated) Sum of polycyclic aromatic hydrocarbons (PAH) (from calculations)","search_zh":"水、废水","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250c50","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, Sewage","test_object_en":"Water, Sewage","methodology":"Stężenie lotnych węglowodorów aromatycznych Zakres: benzen (0,20 – 50) μg/l toluen (0,20 – 50) μg/l etylobenzen (0,20 – 50) μg/l o-ksylen (0,20 – 50) μg/l m,p-ksylen (0,40 – 100) μg/l Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) Volatile aromatic hydrocarbon concentration Range: benzene (0,20 – 50) μg/l toluene (0,20 – 50) μg/l ethylobenzene (0,20 – 50) μg/l o-xylene (0,20 – 50) μg/l m,p-xylene (0,40 – 100) μg/l Gas chromatography method with headspace analysis and mass spectrometric detection (HS-GC-MS)","methodology_en":"Volatile aromatic hydrocarbon concentration Range: benzene (0,20 – 50) μg/l toluene (0,20 – 50) μg/l ethylobenzene (0,20 – 50) μg/l o-xylene (0,20 – 50) μg/l m,p-xylene (0,40 – 100) μg/l Gas chromatography method with headspace analysis and mass spectrometric detection (HS-GC-MS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie lotnych węglowodorów aromatycznych Zakres: benzen (0,20 – 50) μg/l toluen (0,20 – 50) μg/l etylobenzen (0,20 – 50) μg/l o-ksylen (0,20 – 50) μg/l m,p-ksylen (0,40 – 100) μg/l Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) Volatile aromatic hydrocarbon concentration Range: benzene (0,20 – 50) μg/l toluene (0,20 – 50) μg/l ethylobenzene (0,20 – 50) μg/l o-xylene (0,20 – 50) μg/l m,p-xylene (0,40 – 100) μg/l Gas chromatography method with headspace analysis and mass spectrometric detection (HS-GC-MS)","reference":"PN-ISO 11423-1:2002","norm_bases":["PN-ISO 11423-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, Sewage Stężenie lotnych węglowodorów aromatycznych Zakres: benzen (0,20 – 50) μg/l toluen (0,20 – 50) μg/l etylobenzen (0,20 – 50) μg/l o-ksylen (0,20 – 50) μg/l m,p-ksylen (0,40 – 100) μg/l Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) Volatile aromatic hydrocarbon concentration Range: benzene (0,20 – 50) μg/l toluene (0,20 – 50) μg/l ethylobenzene (0,20 – 50) μg/l o-xylene (0,20 – 50) μg/l m,p-xylene (0,40 – 100) μg/l Gas chromatography method with headspace analysis and mass spectrometric detection (HS-GC-MS) PN-ISO 11423-1:2002 Woda, scieki Water, Sewage Stezenie lotnych weglowodorow aromatycznych Zakres: benzen (0,20 – 50) μg/l toluen (0,20 – 50) μg/l etylobenzen (0,20 – 50) μg/l o-ksylen (0,20 – 50) μg/l m,p-ksylen (0,40 – 100) μg/l Metoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) Volatile aromatic hydrocarbon concentration Range: benzene (0,20 – 50) μg/l toluene (0,20 – 50) μg/l ethylobenzene (0,20 – 50) μg/l o-xylene (0,20 – 50) μg/l m,p-xylene (0,40 – 100) μg/l Gas chromatography method with headspace analysis and mass spectrometric detection (HS-GC-MS) PN-ISO 11423-1:2002","categories":["water"],"row_index":436,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, Sewage Volatile aromatic hydrocarbon concentration Range: benzene (0,20 – 50) μg/l toluene (0,20 – 50) μg/l ethylobenzene (0,20 – 50) μg/l o-xylene (0,20 – 50) μg/l m,p-xylene (0,40 – 100) μg/l Gas chromatography method with headspace analysis and mass spectrometric detection (HS-GC-MS) PN-ISO 11423-1:2002","search_zh":"水、废水 PN-ISO 11423-1:2002","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250c51","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, Sewage","test_object_en":"Water, Sewage","methodology":"Suma lotnych węglowodorów aromatycznych (z obliczeń) Sum of volatile aromatic hydrocarbon (from calculations)","methodology_en":"Sum of volatile aromatic hydrocarbon (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma lotnych węglowodorów aromatycznych (z obliczeń) Sum of volatile aromatic hydrocarbon (from calculations)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, Sewage Suma lotnych węglowodorów aromatycznych (z obliczeń) Sum of volatile aromatic hydrocarbon (from calculations) Woda, scieki Water, Sewage Suma lotnych weglowodorow aromatycznych (z obliczen) Sum of volatile aromatic hydrocarbon (from calculations)","categories":["water"],"row_index":437,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, Sewage Sum of volatile aromatic hydrocarbon (from calculations)","search_zh":"水、废水","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250c52","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, Sewage","test_object_en":"Water, Sewage","methodology":"Stężenie fenoli: Zakres: pentachlorofenolu (PCP) (0,010 – 2,0) μg/l 2,4,6-trichlorofenolu (0,050 – 2,0) μg/l Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) Phenols concentration : Range: Pentachlorophenol (PCP) (0,010 – 2,0) μg/l 2,4,6-trichlorophenol (0,050 – 2,0) μg/l Gas chromatography method with electron capture detection (GC-ECD)","methodology_en":"Phenols concentration : Range: Pentachlorophenol (PCP) (0,010 – 2,0) μg/l 2,4,6-trichlorophenol (0,050 – 2,0) μg/l Gas chromatography method with electron capture detection (GC-ECD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fenoli: Zakres: pentachlorofenolu (PCP) (0,010 – 2,0) μg/l 2,4,6-trichlorofenolu (0,050 – 2,0) μg/l Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) Phenols concentration : Range: Pentachlorophenol (PCP) (0,010 – 2,0) μg/l 2,4,6-trichlorophenol (0,050 – 2,0) μg/l Gas chromatography method with electron capture detection (GC-ECD)","reference":"PN-EN 12673:2004","norm_bases":["PN-EN 12673:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, Sewage Stężenie fenoli: Zakres: pentachlorofenolu (PCP) (0,010 – 2,0) μg/l 2,4,6-trichlorofenolu (0,050 – 2,0) μg/l Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) Phenols concentration : Range: Pentachlorophenol (PCP) (0,010 – 2,0) μg/l 2,4,6-trichlorophenol (0,050 – 2,0) μg/l Gas chromatography method with electron capture detection (GC-ECD) PN-EN 12673:2004 Woda, scieki Water, Sewage Stezenie fenoli: Zakres: pentachlorofenolu (PCP) (0,010 – 2,0) μg/l 2,4,6-trichlorofenolu (0,050 – 2,0) μg/l Metoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) Phenols concentration : Range: Pentachlorophenol (PCP) (0,010 – 2,0) μg/l 2,4,6-trichlorophenol (0,050 – 2,0) μg/l Gas chromatography method with electron capture detection (GC-ECD) PN-EN 12673:2004","categories":["water"],"row_index":438,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, Sewage Phenols concentration : Range: Pentachlorophenol (PCP) (0,010 – 2,0) μg/l 2,4,6-trichlorophenol (0,050 – 2,0) μg/l Gas chromatography method with electron capture detection (GC-ECD) PN-EN 12673:2004","search_zh":"水、废水 PN-EN 12673:2004","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250c53","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, Sewage","test_object_en":"Water, Sewage","methodology":"Stężenie chlorobenzenów: Zakres: heksachlorobenzenu (HCB) (0,010 – 2,0) μg/l pentachlorobenzenu (0,010 – 2,0) μg/l Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) Chlorobenzenes concentration : Range: hexachlorobenzene (HCB) (0,010 – 2,0) μg/l pentachlorobenzene (0,010 – 2,0) μg/l Gas chromatography method with electron capture detection (GC-ECD)","methodology_en":"Chlorobenzenes concentration : Range: hexachlorobenzene (HCB) (0,010 – 2,0) μg/l pentachlorobenzene (0,010 – 2,0) μg/l Gas chromatography method with electron capture detection (GC-ECD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorobenzenów: Zakres: heksachlorobenzenu (HCB) (0,010 – 2,0) μg/l pentachlorobenzenu (0,010 – 2,0) μg/l Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) Chlorobenzenes concentration : Range: hexachlorobenzene (HCB) (0,010 – 2,0) μg/l pentachlorobenzene (0,010 – 2,0) μg/l Gas chromatography method with electron capture detection (GC-ECD)","reference":"PN-EN ISO 6468:2002","norm_bases":["PN-EN ISO 6468:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, Sewage Stężenie chlorobenzenów: Zakres: heksachlorobenzenu (HCB) (0,010 – 2,0) μg/l pentachlorobenzenu (0,010 – 2,0) μg/l Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) Chlorobenzenes concentration : Range: hexachlorobenzene (HCB) (0,010 – 2,0) μg/l pentachlorobenzene (0,010 – 2,0) μg/l Gas chromatography method with electron capture detection (GC-ECD) PN-EN ISO 6468:2002 Woda, scieki Water, Sewage Stezenie chlorobenzenow: Zakres: heksachlorobenzenu (HCB) (0,010 – 2,0) μg/l pentachlorobenzenu (0,010 – 2,0) μg/l Metoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) Chlorobenzenes concentration : Range: hexachlorobenzene (HCB) (0,010 – 2,0) μg/l pentachlorobenzene (0,010 – 2,0) μg/l Gas chromatography method with electron capture detection (GC-ECD) PN-EN ISO 6468:2002","categories":["water"],"row_index":439,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, Sewage Chlorobenzenes concentration : Range: hexachlorobenzene (HCB) (0,010 – 2,0) μg/l pentachlorobenzene (0,010 – 2,0) μg/l Gas chromatography method with electron capture detection (GC-ECD) PN-EN ISO 6468:2002","search_zh":"水、废水 PN-EN ISO 6468:2002","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250c54","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, Sewage","test_object_en":"Water, Sewage","methodology":"Stężenie pestycydów chloroorganicznych Zakres: aldryna (0,020 – 10,0) μg/l endryna (0,020 – 10,0) μg/l dieldryna (0,020 – 10,0) μg/l heptachlor (0,020 – 10,0) μg/l epoksyd heptachloru A (0,020 – 10,0) μg/l metoksychlor (0,020 – 10,0) μg/l α-heksachlorocykloheksan (α-HCH) (0,020 – 10,0) μg/l β-heksachlorocykloheksan (β-HCH) (0,020 – 10,0) μg/l γ-heksachlorocykloheksan (lindan, γ- HCH) (0,020 – 10,0) μg/l p,p’–dichlorodifenylotrichloroetan (p,p’-DDT) (0,020 – 10,0) μg/l p,p’–dichlorodifenylodichloroetan (p,p’-DDD) (0,020 – 10,0) μg/l p,p’–dichlorodifenylodichloroetylen (p,p’-DDE) (0,020 – 10,0) μg/l izodryna (0,020 – 10,0) μg/l tetradifon (0,020 – 10,0) μg/l alachlor (0,050 – 10,0) μg/l Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","methodology_en":"Organochlorine pesticide concentration Range: aldrin (0,020 – 10,0) μg/l endrin (0,020 – 10,0) μg/l dieldrin (0,020 – 10,0) μg/l heptachlor (0,020 – 10,0) μg/l heptachlor epoxide A (0,020 – 10,0) μg/l methoxychlor (0,020 – 10,0) μg/l α-hexachlorocyclohexane (α-HCH) (0,020 – 10,0) μg/l β-hexachlorocyclohexane (β-HCH) (0,020 – 10,0) μg/l γ-hexachlorocyclohexane (lindane, γ- HCH) (0,020 – 10,0) μg/l p,p’–dichlorodiphenyltrichloroethane (p,p’-DDT) (0,020 – 10,0) μg/l p,p’–dichlorodiphenyldichloroethane (p,p’-DDD) (0,020 – 10,0) μg/l p,p’–dichlorodiphenyldichloroethylene (p,p’-DDE) (0,020 – 10,0) μg/l isodrin (0,020 – 10,0) μg/l tetradifon (0,020 – 10,0) μg/l alachlor (0,050 – 10,0) μg/l Gas chromatography with electron capture detection (GC-ECD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pestycydów chloroorganicznych Zakres: aldryna (0,020 – 10,0) μg/l endryna (0,020 – 10,0) μg/l dieldryna (0,020 – 10,0) μg/l heptachlor (0,020 – 10,0) μg/l epoksyd heptachloru A (0,020 – 10,0) μg/l metoksychlor (0,020 – 10,0) μg/l α-heksachlorocykloheksan (α-HCH) (0,020 – 10,0) μg/l β-heksachlorocykloheksan (β-HCH) (0,020 – 10,0) μg/l γ-heksachlorocykloheksan (lindan, γ- HCH) (0,020 – 10,0) μg/l p,p’–dichlorodifenylotrichloroetan (p,p’-DDT) (0,020 – 10,0) μg/l p,p’–dichlorodifenylodichloroetan (p,p’-DDD) (0,020 – 10,0) μg/l p,p’–dichlorodifenylodichloroetylen (p,p’-DDE) (0,020 – 10,0) μg/l izodryna (0,020 – 10,0) μg/l tetradifon (0,020 – 10,0) μg/l alachlor (0,050 – 10,0) μg/l Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN ISO 6468:2002 z wyłączeniem pkt 7.2 SO-4/ZLGIG/WYK-08 ed. 1 z dn. 01.08.2025","norm_bases":["PN-EN ISO 6468:2002 z wyłączeniem pkt 7.2 SO-4/ZLGIG/WYK-08 ed. 1 z dn. 01.08.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, Sewage Stężenie pestycydów chloroorganicznych Zakres: aldryna (0,020 – 10,0) μg/l endryna (0,020 – 10,0) μg/l dieldryna (0,020 – 10,0) μg/l heptachlor (0,020 – 10,0) μg/l epoksyd heptachloru A (0,020 – 10,0) μg/l metoksychlor (0,020 – 10,0) μg/l α-heksachlorocykloheksan (α-HCH) (0,020 – 10,0) μg/l β-heksachlorocykloheksan (β-HCH) (0,020 – 10,0) μg/l γ-heksachlorocykloheksan (lindan, γ- HCH) (0,020 – 10,0) μg/l p,p’–dichlorodifenylotrichloroetan (p,p’-DDT) (0,020 – 10,0) μg/l p,p’–dichlorodifenylodichloroetan (p,p’-DDD) (0,020 – 10,0) μg/l p,p’–dichlorodifenylodichloroetylen (p,p’-DDE) (0,020 – 10,0) μg/l izodryna (0,020 – 10,0) μg/l tetradifon (0,020 – 10,0) μg/l alachlor (0,050 – 10,0) μg/l Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN ISO 6468:2002 z wyłączeniem pkt 7.2 SO-4/ZLGIG/WYK-08 ed. 1 z dn. 01.08.2025 Woda, scieki Water, Sewage Stezenie pestycydow chloroorganicznych Zakres: aldryna (0,020 – 10,0) μg/l endryna (0,020 – 10,0) μg/l dieldryna (0,020 – 10,0) μg/l heptachlor (0,020 – 10,0) μg/l epoksyd heptachloru A (0,020 – 10,0) μg/l metoksychlor (0,020 – 10,0) μg/l α-heksachlorocykloheksan (α-HCH) (0,020 – 10,0) μg/l β-heksachlorocykloheksan (β-HCH) (0,020 – 10,0) μg/l γ-heksachlorocykloheksan (lindan, γ- HCH) (0,020 – 10,0) μg/l p,p’–dichlorodifenylotrichloroetan (p,p’-DDT) (0,020 – 10,0) μg/l p,p’–dichlorodifenylodichloroetan (p,p’-DDD) (0,020 – 10,0) μg/l p,p’–dichlorodifenylodichloroetylen (p,p’-DDE) (0,020 – 10,0) μg/l izodryna (0,020 – 10,0) μg/l tetradifon (0,020 – 10,0) μg/l alachlor (0,050 – 10,0) μg/l Metoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN ISO 6468:2002 z wylaczeniem pkt 7.2 SO-4/ZLGIG/WYK-08 ed. 1 z dn. 01.08.2025","categories":["water"],"row_index":440,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, Sewage Organochlorine pesticide concentration Range: aldrin (0,020 – 10,0) μg/l endrin (0,020 – 10,0) μg/l dieldrin (0,020 – 10,0) μg/l heptachlor (0,020 – 10,0) μg/l heptachlor epoxide A (0,020 – 10,0) μg/l methoxychlor (0,020 – 10,0) μg/l α-hexachlorocyclohexane (α-HCH) (0,020 – 10,0) μg/l β-hexachlorocyclohexane (β-HCH) (0,020 – 10,0) μg/l γ-hexachlorocyclohexane (lindane, γ- HCH) (0,020 – 10,0) μg/l p,p’–dichlorodiphenyltrichloroethane (p,p’-DDT) (0,020 – 10,0) μg/l p,p’–dichlorodiphenyldichloroethane (p,p’-DDD) (0,020 – 10,0) μg/l p,p’–dichlorodiphenyldichloroethylene (p,p’-DDE) (0,020 – 10,0) μg/l isodrin (0,020 – 10,0) μg/l tetradifon (0,020 – 10,0) μg/l alachlor (0,050 – 10,0) μg/l Gas chromatography with electron capture detection (GC-ECD) PN-EN ISO 6468:2002 z wyłączeniem pkt 7.2 SO-4/ZLGIG/WYK-08 ed. 1 z dn. 01.08.2025","search_zh":"水、废水 PN-EN ISO 6468:2002 z wyłączeniem pkt 7.2 SO-4/ZLGIG/WYK-08 ed. 1 z dn. 01.08.2025","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250c55","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, Sewage","test_object_en":"Water, Sewage","methodology":"Organochlorines pesticides concentration aldrin (0,020 – 10,0) μg/l endrin (0,020 – 10,0) μg/l dieldrin (0,020 – 10,0) μg/l heptachlor (0,020 – 10,0) μg/l heptachlor A epoxide (0,020 - 10,0) μg/l methoxychlor (0,020 – 10,0) μg/l α-hexachlorocyclohexane (α-HCH) (0,020 – 10,0) μg/l β-hexachlorocyclohexane (β-HCH) (0,020 – 10,0) μg/l γ-hexachlorocyclohexane (lindane, γ-HCH) (0,020 – 10,0) μg/l p,p'-dichlorodiphenyltrichloroethane (p,p'-DDT) (0,020 – 10,0) μg/l p,p'-dichlorodiphenyldichloroethane (p,p'-DDD) (0,020 – 10,0) μg/l p,p'-dichlorodiphenyldichloroethylene (p,p'-DDE) (0,020 – 10,0) μg/l isodrine (0,020 – 10,0) μg/l tetradifon (0,020 – 10,0) μg/l alachlor (0,050 – 10,0) μg/l Gas chromatography method with electron capture detection (GC-ECD)","methodology_en":"Organochlorines pesticides concentration aldrin (0,020 – 10,0) μg/l endrin (0,020 – 10,0) μg/l dieldrin (0,020 – 10,0) μg/l heptachlor (0,020 – 10,0) μg/l heptachlor A epoxide (0,020 - 10,0) μg/l methoxychlor (0,020 – 10,0) μg/l α-hexachlorocyclohexane (α-HCH) (0,020 – 10,0) μg/l β-hexachlorocyclohexane (β-HCH) (0,020 – 10,0) μg/l γ-hexachlorocyclohexane (lindane, γ-HCH) (0,020 – 10,0) μg/l p,p'-dichlorodiphenyltrichloroethane (p,p'-DDT) (0,020 – 10,0) μg/l p,p'-dichlorodiphenyldichloroethane (p,p'-DDD) (0,020 – 10,0) μg/l p,p'-dichlorodiphenyldichloroethylene (p,p'-DDE) (0,020 – 10,0) μg/l isodrine (0,020 – 10,0) μg/l tetradifon (0,020 – 10,0) μg/l alachlor (0,050 – 10,0) μg/l Gas chromatography method with electron capture detection (GC-ECD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Organochlorines pesticides concentration aldrin (0,020 – 10,0) μg/l endrin (0,020 – 10,0) μg/l dieldrin (0,020 – 10,0) μg/l heptachlor (0,020 – 10,0) μg/l heptachlor A epoxide (0,020 - 10,0) μg/l methoxychlor (0,020 – 10,0) μg/l α-hexachlorocyclohexane (α-HCH) (0,020 – 10,0) μg/l β-hexachlorocyclohexane (β-HCH) (0,020 – 10,0) μg/l γ-hexachlorocyclohexane (lindane, γ-HCH) (0,020 – 10,0) μg/l p,p'-dichlorodiphenyltrichloroethane (p,p'-DDT) (0,020 – 10,0) μg/l p,p'-dichlorodiphenyldichloroethane (p,p'-DDD) (0,020 – 10,0) μg/l p,p'-dichlorodiphenyldichloroethylene (p,p'-DDE) (0,020 – 10,0) μg/l isodrine (0,020 – 10,0) μg/l tetradifon (0,020 – 10,0) μg/l alachlor (0,050 – 10,0) μg/l Gas chromatography method with electron capture detection (GC-ECD)","reference":"PN-EN ISO 6468:2002 excluding pt 7.2 SO-4/ZLGIG/WYK-08 edition 1st of 01/08/2025 PN-EN ISO 6468:2002 z wyłączeniem pkt 7.2 SO-4/ZLGIG/WYK-08 ed. 1 z dn. 01.08.2025 PN-EN ISO 6468:2002 excluding pt 7.2 SO-4/ZLGIG/WYK-08 edition 1st of 01/08/2025","norm_bases":["PN-EN ISO 6468:2002 excluding pt 7.2 SO-4/ZLGIG/WYK-08 edition 1st of 01/08/2025 PN-EN ISO 6468:2002 z wyłączeniem pkt 7.2 SO-4/ZLGIG/WYK-08 ed. 1 z dn. 01.08.2025 PN-EN ISO 6468:2002 excluding pt 7.2 SO-4/ZLGIG/WYK-08 edition 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, Sewage Organochlorines pesticides concentration aldrin (0,020 – 10,0) μg/l endrin (0,020 – 10,0) μg/l dieldrin (0,020 – 10,0) μg/l heptachlor (0,020 – 10,0) μg/l heptachlor A epoxide (0,020 - 10,0) μg/l methoxychlor (0,020 – 10,0) μg/l α-hexachlorocyclohexane (α-HCH) (0,020 – 10,0) μg/l β-hexachlorocyclohexane (β-HCH) (0,020 – 10,0) μg/l γ-hexachlorocyclohexane (lindane, γ-HCH) (0,020 – 10,0) μg/l p,p'-dichlorodiphenyltrichloroethane (p,p'-DDT) (0,020 – 10,0) μg/l p,p'-dichlorodiphenyldichloroethane (p,p'-DDD) (0,020 – 10,0) μg/l p,p'-dichlorodiphenyldichloroethylene (p,p'-DDE) (0,020 – 10,0) μg/l isodrine (0,020 – 10,0) μg/l tetradifon (0,020 – 10,0) μg/l alachlor (0,050 – 10,0) μg/l Gas chromatography method with electron capture detection (GC-ECD) PN-EN ISO 6468:2002 excluding pt 7.2 SO-4/ZLGIG/WYK-08 edition 1st of 01/08/2025 PN-EN ISO 6468:2002 z wyłączeniem pkt 7.2 SO-4/ZLGIG/WYK-08 ed. 1 z dn. 01.08.2025 PN-EN ISO 6468:2002 excluding pt 7.2 SO-4/ZLGIG/WYK-08 edition 1st of 01/08/2025 Woda, scieki Water, Sewage Organochlorines pesticides concentration aldrin (0,020 – 10,0) μg/l endrin (0,020 – 10,0) μg/l dieldrin (0,020 – 10,0) μg/l heptachlor (0,020 – 10,0) μg/l heptachlor A epoxide (0,020 - 10,0) μg/l methoxychlor (0,020 – 10,0) μg/l α-hexachlorocyclohexane (α-HCH) (0,020 – 10,0) μg/l β-hexachlorocyclohexane (β-HCH) (0,020 – 10,0) μg/l γ-hexachlorocyclohexane (lindane, γ-HCH) (0,020 – 10,0) μg/l p,p'-dichlorodiphenyltrichloroethane (p,p'-DDT) (0,020 – 10,0) μg/l p,p'-dichlorodiphenyldichloroethane (p,p'-DDD) (0,020 – 10,0) μg/l p,p'-dichlorodiphenyldichloroethylene (p,p'-DDE) (0,020 – 10,0) μg/l isodrine (0,020 – 10,0) μg/l tetradifon (0,020 – 10,0) μg/l alachlor (0,050 – 10,0) μg/l Gas chromatography method with electron capture detection (GC-ECD) PN-EN ISO 6468:2002 excluding pt 7.2 SO-4/ZLGIG/WYK-08 edition 1st of 01/08/2025 PN-EN ISO 6468:2002 z wylaczeniem pkt 7.2 SO-4/ZLGIG/WYK-08 ed. 1 z dn. 01.08.2025 PN-EN ISO 6468:2002 excluding pt 7.2 SO-4/ZLGIG/WYK-08 edition 1st of 01/08/2025","categories":["water"],"row_index":441,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, Sewage Organochlorines pesticides concentration aldrin (0,020 – 10,0) μg/l endrin (0,020 – 10,0) μg/l dieldrin (0,020 – 10,0) μg/l heptachlor (0,020 – 10,0) μg/l heptachlor A epoxide (0,020 - 10,0) μg/l methoxychlor (0,020 – 10,0) μg/l α-hexachlorocyclohexane (α-HCH) (0,020 – 10,0) μg/l β-hexachlorocyclohexane (β-HCH) (0,020 – 10,0) μg/l γ-hexachlorocyclohexane (lindane, γ-HCH) (0,020 – 10,0) μg/l p,p'-dichlorodiphenyltrichloroethane (p,p'-DDT) (0,020 – 10,0) μg/l p,p'-dichlorodiphenyldichloroethane (p,p'-DDD) (0,020 – 10,0) μg/l p,p'-dichlorodiphenyldichloroethylene (p,p'-DDE) (0,020 – 10,0) μg/l isodrine (0,020 – 10,0) μg/l tetradifon (0,020 – 10,0) μg/l alachlor (0,050 – 10,0) μg/l Gas chromatography method with electron capture detection (GC-ECD) PN-EN ISO 6468:2002 excluding pt 7.2 SO-4/ZLGIG/WYK-08 edition 1st of 01/08/2025 PN-EN ISO 6468:2002 z wyłączeniem pkt 7.2 SO-4/ZLGIG/WYK-08 ed. 1 z dn. 01.08.2025 PN-EN ISO 6468:2002 excluding pt 7.2 SO-4/ZLGIG/WYK-08 edition 1st of 01/08/2025","search_zh":"水、废水 PN-EN ISO 6468:2002 excluding pt 7.2 SO-4/ZLGIG/WYK-08 edition 1st of 01/08/2025 PN-EN ISO 6468:2002 z wyłączeniem pkt 7.2 SO-4/ZLGIG/WYK-08 ed. 1 z dn. 01.08.2025 PN-EN ISO 6468:2002 excluding pt 7.2 SO-4/ZLGIG/WYK-08 edition 1st of 01/08/2025","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250c56","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, Sewage","test_object_en":"Water, Sewage","methodology":"Stężenie pestycydów azotoorganicznych Zakres: trifluralina (0,020 – 10,0) μg/l Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) Organonitrogen pesticides concentration Range: trifluralin (0,020 – 10,0) μg/l Gas chromatography method with electron capture detection (GC-ECD)","methodology_en":"Organonitrogen pesticides concentration Range: trifluralin (0,020 – 10,0) μg/l Gas chromatography method with electron capture detection (GC-ECD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pestycydów azotoorganicznych Zakres: trifluralina (0,020 – 10,0) μg/l Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) Organonitrogen pesticides concentration Range: trifluralin (0,020 – 10,0) μg/l Gas chromatography method with electron capture detection (GC-ECD)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, Sewage Stężenie pestycydów azotoorganicznych Zakres: trifluralina (0,020 – 10,0) μg/l Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) Organonitrogen pesticides concentration Range: trifluralin (0,020 – 10,0) μg/l Gas chromatography method with electron capture detection (GC-ECD) Woda, scieki Water, Sewage Stezenie pestycydow azotoorganicznych Zakres: trifluralina (0,020 – 10,0) μg/l Metoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) Organonitrogen pesticides concentration Range: trifluralin (0,020 – 10,0) μg/l Gas chromatography method with electron capture detection (GC-ECD)","categories":["water"],"row_index":442,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, Sewage Organonitrogen pesticides concentration Range: trifluralin (0,020 – 10,0) μg/l Gas chromatography method with electron capture detection (GC-ECD)","search_zh":"水、废水","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250c57","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, Sewage","test_object_en":"Water, Sewage","methodology":"Stężenie pestycydów fosforoorganicznych Zakres: chlorpyrifos (0,020 – 10,0) μg/l fenitrothion (0,050 – 10,0) μg/l Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) Organophosphate pesticide concentration Range: chlorpyrifos (0,020 – 10,0) μg/l fenitrothion (0,050 – 10,0) μg/l Gas chromatography method with electron capture detection (GC-ECD)","methodology_en":"Organophosphate pesticide concentration Range: chlorpyrifos (0,020 – 10,0) μg/l fenitrothion (0,050 – 10,0) μg/l Gas chromatography method with electron capture detection (GC-ECD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pestycydów fosforoorganicznych Zakres: chlorpyrifos (0,020 – 10,0) μg/l fenitrothion (0,050 – 10,0) μg/l Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) Organophosphate pesticide concentration Range: chlorpyrifos (0,020 – 10,0) μg/l fenitrothion (0,050 – 10,0) μg/l Gas chromatography method with electron capture detection (GC-ECD)","reference":"PN-EN ISO 6468:2002 z wyłączeniem pkt 7.2 SO-4/ZLGIG/WYK-08 ed. 1 z dn. 01.08.2025 PN-EN ISO 6468:2002 excluding pt 7.2 SO-4/ZLGIG/WYK-08 edition 1st of 01/08/2025","norm_bases":["PN-EN ISO 6468:2002 z wyłączeniem pkt 7.2 SO-4/ZLGIG/WYK-08 ed. 1 z dn. 01.08.2025 PN-EN ISO 6468:2002 excluding pt 7.2 SO-4/ZLGIG/WYK-08 edition 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, Sewage Stężenie pestycydów fosforoorganicznych Zakres: chlorpyrifos (0,020 – 10,0) μg/l fenitrothion (0,050 – 10,0) μg/l Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) Organophosphate pesticide concentration Range: chlorpyrifos (0,020 – 10,0) μg/l fenitrothion (0,050 – 10,0) μg/l Gas chromatography method with electron capture detection (GC-ECD) PN-EN ISO 6468:2002 z wyłączeniem pkt 7.2 SO-4/ZLGIG/WYK-08 ed. 1 z dn. 01.08.2025 PN-EN ISO 6468:2002 excluding pt 7.2 SO-4/ZLGIG/WYK-08 edition 1st of 01/08/2025 Woda, scieki Water, Sewage Stezenie pestycydow fosforoorganicznych Zakres: chlorpyrifos (0,020 – 10,0) μg/l fenitrothion (0,050 – 10,0) μg/l Metoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) Organophosphate pesticide concentration Range: chlorpyrifos (0,020 – 10,0) μg/l fenitrothion (0,050 – 10,0) μg/l Gas chromatography method with electron capture detection (GC-ECD) PN-EN ISO 6468:2002 z wylaczeniem pkt 7.2 SO-4/ZLGIG/WYK-08 ed. 1 z dn. 01.08.2025 PN-EN ISO 6468:2002 excluding pt 7.2 SO-4/ZLGIG/WYK-08 edition 1st of 01/08/2025","categories":["water"],"row_index":443,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, Sewage Organophosphate pesticide concentration Range: chlorpyrifos (0,020 – 10,0) μg/l fenitrothion (0,050 – 10,0) μg/l Gas chromatography method with electron capture detection (GC-ECD) PN-EN ISO 6468:2002 z wyłączeniem pkt 7.2 SO-4/ZLGIG/WYK-08 ed. 1 z dn. 01.08.2025 PN-EN ISO 6468:2002 excluding pt 7.2 SO-4/ZLGIG/WYK-08 edition 1st of 01/08/2025","search_zh":"水、废水 PN-EN ISO 6468:2002 z wyłączeniem pkt 7.2 SO-4/ZLGIG/WYK-08 ed. 1 z dn. 01.08.2025 PN-EN ISO 6468:2002 excluding pt 7.2 SO-4/ZLGIG/WYK-08 edition 1st of 01/08/2025","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250c58","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, Sewage","test_object_en":"Water, Sewage","methodology":"Stężenie pestycydów chloroorganicznych Zakres: o,p’–dichlorodifenylotrichloroetan (o,p’- DDT) (0,010 – 2,0) μg/l heksachlorobutadien (HCBD) (0,010 – 2,0) μg/l α-Endosulfan (Endosulfan I) (0,010 – 2,0) μg/l Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) Organochlorine pesticides concentration Range: o,p'-dichlorodiphenyltrichloroethane (o,p'-DDT) (0,010 – 2,0) μg/l hexachlorobutadiene (HCBD) (0,010 – 2,0) μg/l α-Endosulfan (Endosulfan I) (0,010 – 2,0) μg/l Gas chromatography method with electron capture detection (GC-ECD)","methodology_en":"Organochlorine pesticides concentration Range: o,p'-dichlorodiphenyltrichloroethane (o,p'-DDT) (0,010 – 2,0) μg/l hexachlorobutadiene (HCBD) (0,010 – 2,0) μg/l α-Endosulfan (Endosulfan I) (0,010 – 2,0) μg/l Gas chromatography method with electron capture detection (GC-ECD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pestycydów chloroorganicznych Zakres: o,p’–dichlorodifenylotrichloroetan (o,p’- DDT) (0,010 – 2,0) μg/l heksachlorobutadien (HCBD) (0,010 – 2,0) μg/l α-Endosulfan (Endosulfan I) (0,010 – 2,0) μg/l Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) Organochlorine pesticides concentration Range: o,p'-dichlorodiphenyltrichloroethane (o,p'-DDT) (0,010 – 2,0) μg/l hexachlorobutadiene (HCBD) (0,010 – 2,0) μg/l α-Endosulfan (Endosulfan I) (0,010 – 2,0) μg/l Gas chromatography method with electron capture detection (GC-ECD)","reference":"PN-EN ISO 6468:2002","norm_bases":["PN-EN ISO 6468:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, Sewage Stężenie pestycydów chloroorganicznych Zakres: o,p’–dichlorodifenylotrichloroetan (o,p’- DDT) (0,010 – 2,0) μg/l heksachlorobutadien (HCBD) (0,010 – 2,0) μg/l α-Endosulfan (Endosulfan I) (0,010 – 2,0) μg/l Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) Organochlorine pesticides concentration Range: o,p'-dichlorodiphenyltrichloroethane (o,p'-DDT) (0,010 – 2,0) μg/l hexachlorobutadiene (HCBD) (0,010 – 2,0) μg/l α-Endosulfan (Endosulfan I) (0,010 – 2,0) μg/l Gas chromatography method with electron capture detection (GC-ECD) PN-EN ISO 6468:2002 Woda, scieki Water, Sewage Stezenie pestycydow chloroorganicznych Zakres: o,p’–dichlorodifenylotrichloroetan (o,p’- DDT) (0,010 – 2,0) μg/l heksachlorobutadien (HCBD) (0,010 – 2,0) μg/l α-Endosulfan (Endosulfan I) (0,010 – 2,0) μg/l Metoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) Organochlorine pesticides concentration Range: o,p'-dichlorodiphenyltrichloroethane (o,p'-DDT) (0,010 – 2,0) μg/l hexachlorobutadiene (HCBD) (0,010 – 2,0) μg/l α-Endosulfan (Endosulfan I) (0,010 – 2,0) μg/l Gas chromatography method with electron capture detection (GC-ECD) PN-EN ISO 6468:2002","categories":["water"],"row_index":444,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, Sewage Organochlorine pesticides concentration Range: o,p'-dichlorodiphenyltrichloroethane (o,p'-DDT) (0,010 – 2,0) μg/l hexachlorobutadiene (HCBD) (0,010 – 2,0) μg/l α-Endosulfan (Endosulfan I) (0,010 – 2,0) μg/l Gas chromatography method with electron capture detection (GC-ECD) PN-EN ISO 6468:2002","search_zh":"水、废水 PN-EN ISO 6468:2002","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250c59","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, Sewage","test_object_en":"Water, Sewage","methodology":"Stężenie pestycydów azotoorganicznych (triazynowych): atrazyna, symazyna woda - zakres: (0,050 – 2,0) μg/l ścieki - zakres: (0,10 – 2,0) μg/l Metoda chromatografii cieczowej z detekcją spektrofotometryczną (HPLC- UV) Organo-nitrogen (triazine) pesticides concentration : atrazine, simazine water - range: (0,050 – 2,0) μg/l sewage- range: (0,10 – 2,0) μg/l Liquid chromatography method with spectrophotometric detection (HPLC-UV)","methodology_en":"Organo-nitrogen (triazine) pesticides concentration : atrazine, simazine water - range: (0,050 – 2,0) μg/l sewage- range: (0,10 – 2,0) μg/l Liquid chromatography method with spectrophotometric detection (HPLC-UV)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pestycydów azotoorganicznych (triazynowych): atrazyna, symazyna woda - zakres: (0,050 – 2,0) μg/l ścieki - zakres: (0,10 – 2,0) μg/l Metoda chromatografii cieczowej z detekcją spektrofotometryczną (HPLC- UV) Organo-nitrogen (triazine) pesticides concentration : atrazine, simazine water - range: (0,050 – 2,0) μg/l sewage- range: (0,10 – 2,0) μg/l Liquid chromatography method with spectrophotometric detection (HPLC-UV)","reference":"PN-EN ISO 11369:2002","norm_bases":["PN-EN ISO 11369:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, Sewage Stężenie pestycydów azotoorganicznych (triazynowych): atrazyna, symazyna woda - zakres: (0,050 – 2,0) μg/l ścieki - zakres: (0,10 – 2,0) μg/l Metoda chromatografii cieczowej z detekcją spektrofotometryczną (HPLC- UV) Organo-nitrogen (triazine) pesticides concentration : atrazine, simazine water - range: (0,050 – 2,0) μg/l sewage- range: (0,10 – 2,0) μg/l Liquid chromatography method with spectrophotometric detection (HPLC-UV) PN-EN ISO 11369:2002 Woda, scieki Water, Sewage Stezenie pestycydow azotoorganicznych (triazynowych): atrazyna, symazyna woda - zakres: (0,050 – 2,0) μg/l scieki - zakres: (0,10 – 2,0) μg/l Metoda chromatografii cieczowej z detekcja spektrofotometryczna (HPLC- UV) Organo-nitrogen (triazine) pesticides concentration : atrazine, simazine water - range: (0,050 – 2,0) μg/l sewage- range: (0,10 – 2,0) μg/l Liquid chromatography method with spectrophotometric detection (HPLC-UV) PN-EN ISO 11369:2002","categories":["water"],"row_index":445,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, Sewage Organo-nitrogen (triazine) pesticides concentration : atrazine, simazine water - range: (0,050 – 2,0) μg/l sewage- range: (0,10 – 2,0) μg/l Liquid chromatography method with spectrophotometric detection (HPLC-UV) PN-EN ISO 11369:2002","search_zh":"水、废水 PN-EN ISO 11369:2002","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250c5a","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, Sewage","test_object_en":"Water, Sewage","methodology":"Stężenie pestycydów fosforoorganicznych: chlorfenwinfos woda - zakres: (0,050 – 2,0) μg/l ścieki - zakres: (0,10 – 2,0) μg/l Metoda chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) Organophosphate pesticide concentration: chlorfenvinphos water - range: (0,050 – 2,0) μg/l sewage - range: (0,10 – 2,0) μg/l Liquid chromatography method with spectrophotometric detection (HPLC-UV)","methodology_en":"Organophosphate pesticide concentration: chlorfenvinphos water - range: (0,050 – 2,0) μg/l sewage - range: (0,10 – 2,0) μg/l Liquid chromatography method with spectrophotometric detection (HPLC-UV)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pestycydów fosforoorganicznych: chlorfenwinfos woda - zakres: (0,050 – 2,0) μg/l ścieki - zakres: (0,10 – 2,0) μg/l Metoda chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) Organophosphate pesticide concentration: chlorfenvinphos water - range: (0,050 – 2,0) μg/l sewage - range: (0,10 – 2,0) μg/l Liquid chromatography method with spectrophotometric detection (HPLC-UV)","reference":"PN-EN ISO 11369:2002","norm_bases":["PN-EN ISO 11369:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, Sewage Stężenie pestycydów fosforoorganicznych: chlorfenwinfos woda - zakres: (0,050 – 2,0) μg/l ścieki - zakres: (0,10 – 2,0) μg/l Metoda chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) Organophosphate pesticide concentration: chlorfenvinphos water - range: (0,050 – 2,0) μg/l sewage - range: (0,10 – 2,0) μg/l Liquid chromatography method with spectrophotometric detection (HPLC-UV) PN-EN ISO 11369:2002 Woda, scieki Water, Sewage Stezenie pestycydow fosforoorganicznych: chlorfenwinfos woda - zakres: (0,050 – 2,0) μg/l scieki - zakres: (0,10 – 2,0) μg/l Metoda chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) Organophosphate pesticide concentration: chlorfenvinphos water - range: (0,050 – 2,0) μg/l sewage - range: (0,10 – 2,0) μg/l Liquid chromatography method with spectrophotometric detection (HPLC-UV) PN-EN ISO 11369:2002","categories":["water"],"row_index":446,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, Sewage Organophosphate pesticide concentration: chlorfenvinphos water - range: (0,050 – 2,0) μg/l sewage - range: (0,10 – 2,0) μg/l Liquid chromatography method with spectrophotometric detection (HPLC-UV) PN-EN ISO 11369:2002","search_zh":"水、废水 PN-EN ISO 11369:2002","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250c5b","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, Sewage","test_object_en":"Water, Sewage","methodology":"Suma pestycydów (z obliczeń) Sum of pesticides (from calculations)","methodology_en":"Sum of pesticides (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma pestycydów (z obliczeń) Sum of pesticides (from calculations)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, Sewage Suma pestycydów (z obliczeń) Sum of pesticides (from calculations) Woda, scieki Water, Sewage Suma pestycydow (z obliczen) Sum of pesticides (from calculations)","categories":["water"],"row_index":447,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, Sewage Sum of pesticides (from calculations)","search_zh":"水、废水","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250c5c","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda, ścieki Water, Sewage","test_object_en":"Water, Sewage","methodology":"Stężenie 1,2-dichloroetanu (EDC) Zakres: (1,0 – 100) μg/l Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) 1,2-Dichloroethane concentration (EDC) Range: (1,0 – 100) μg/l Gas chromatography method with electron capture detection (GC-ECD)","methodology_en":"1,2-Dichloroethane concentration (EDC) Range: (1,0 – 100) μg/l Gas chromatography method with electron capture detection (GC-ECD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie 1,2-dichloroetanu (EDC) Zakres: (1,0 – 100) μg/l Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) 1,2-Dichloroethane concentration (EDC) Range: (1,0 – 100) μg/l Gas chromatography method with electron capture detection (GC-ECD)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Water, Sewage Stężenie 1,2-dichloroetanu (EDC) Zakres: (1,0 – 100) μg/l Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) 1,2-Dichloroethane concentration (EDC) Range: (1,0 – 100) μg/l Gas chromatography method with electron capture detection (GC-ECD) PN-EN ISO 10301:2002 Woda, scieki Water, Sewage Stezenie 1,2-dichloroetanu (EDC) Zakres: (1,0 – 100) μg/l Metoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) 1,2-Dichloroethane concentration (EDC) Range: (1,0 – 100) μg/l Gas chromatography method with electron capture detection (GC-ECD) PN-EN ISO 10301:2002","categories":["water"],"row_index":448,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, Sewage 1,2-Dichloroethane concentration (EDC) Range: (1,0 – 100) μg/l Gas chromatography method with electron capture detection (GC-ECD) PN-EN ISO 10301:2002","search_zh":"水、废水 PN-EN ISO 10301:2002","test_object_zh":"水、废水"},{"_id":"6a5a55ef9af9f73f38250c5d","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda Water","test_object_en":"Water","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA) Zakres: benzo(b)fluoranten (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(k)fluoranten (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(a)piren (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(g,h,i)perylen (2,0 – 30) ng/l (0,0020 – 0,030) µg/l indeno(1,2,3-cd)piren (2,0 – 30) ng/l (0,0020 – 0,030) µg/l dibenzo(a,h)antracen (2,0 – 30) ng/l (0,0020 – 0,030) µg/l Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) Polycyclic aromatic hydrocarbons concentration (PAH): benzo(b)fluoranthene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(k)fluoranthene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(a)pyrene (2,0 – 30) ng/l (0,0020 - 0,030) µg/l benzo(g,h,i)perylene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l indeno(1,2,3-cd)pyrene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l dibenzo(a,h)anthracene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l High-performance liquid chromatography method with fluorescence detection (HPLC-FLD)","methodology_en":"Polycyclic aromatic hydrocarbons concentration (PAH): benzo(b)fluoranthene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(k)fluoranthene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(a)pyrene (2,0 – 30) ng/l (0,0020 - 0,030) µg/l benzo(g,h,i)perylene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l indeno(1,2,3-cd)pyrene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l dibenzo(a,h)anthracene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l High-performance liquid chromatography method with fluorescence detection (HPLC-FLD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA) Zakres: benzo(b)fluoranten (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(k)fluoranten (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(a)piren (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(g,h,i)perylen (2,0 – 30) ng/l (0,0020 – 0,030) µg/l indeno(1,2,3-cd)piren (2,0 – 30) ng/l (0,0020 – 0,030) µg/l dibenzo(a,h)antracen (2,0 – 30) ng/l (0,0020 – 0,030) µg/l Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) Polycyclic aromatic hydrocarbons concentration (PAH): benzo(b)fluoranthene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(k)fluoranthene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(a)pyrene (2,0 – 30) ng/l (0,0020 - 0,030) µg/l benzo(g,h,i)perylene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l indeno(1,2,3-cd)pyrene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l dibenzo(a,h)anthracene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l High-performance liquid chromatography method with fluorescence detection (HPLC-FLD)","reference":"PN-EN ISO 17993:2005 z wyłączeniem pkt 8.1-8.4 SO-4/ZLGIG/WYK-04 ed. 1 z dn. 01.08.2025 PN-EN ISO 17993:2005 excluding pt 8.1-8.4 SO-4/ZLGIG/WYK-04 edition 1st of 01/08/2025","norm_bases":["PN-EN ISO 17993:2005 z wyłączeniem pkt 8.1-8.4 SO-4/ZLGIG/WYK-04 ed. 1 z dn. 01.08.2025 PN-EN ISO 17993:2005 excluding pt 8.1-8.4 SO-4/ZLGIG/WYK-04 edition 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Water Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA) Zakres: benzo(b)fluoranten (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(k)fluoranten (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(a)piren (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(g,h,i)perylen (2,0 – 30) ng/l (0,0020 – 0,030) µg/l indeno(1,2,3-cd)piren (2,0 – 30) ng/l (0,0020 – 0,030) µg/l dibenzo(a,h)antracen (2,0 – 30) ng/l (0,0020 – 0,030) µg/l Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) Polycyclic aromatic hydrocarbons concentration (PAH): benzo(b)fluoranthene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(k)fluoranthene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(a)pyrene (2,0 – 30) ng/l (0,0020 - 0,030) µg/l benzo(g,h,i)perylene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l indeno(1,2,3-cd)pyrene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l dibenzo(a,h)anthracene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l High-performance liquid chromatography method with fluorescence detection (HPLC-FLD) PN-EN ISO 17993:2005 z wyłączeniem pkt 8.1-8.4 SO-4/ZLGIG/WYK-04 ed. 1 z dn. 01.08.2025 PN-EN ISO 17993:2005 excluding pt 8.1-8.4 SO-4/ZLGIG/WYK-04 edition 1st of 01/08/2025 Woda Water Stezenie wielopierscieniowych weglowodorow aromatycznych (WWA) Zakres: benzo(b)fluoranten (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(k)fluoranten (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(a)piren (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(g,h,i)perylen (2,0 – 30) ng/l (0,0020 – 0,030) µg/l indeno(1,2,3-cd)piren (2,0 – 30) ng/l (0,0020 – 0,030) µg/l dibenzo(a,h)antracen (2,0 – 30) ng/l (0,0020 – 0,030) µg/l Metoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) Polycyclic aromatic hydrocarbons concentration (PAH): benzo(b)fluoranthene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(k)fluoranthene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(a)pyrene (2,0 – 30) ng/l (0,0020 - 0,030) µg/l benzo(g,h,i)perylene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l indeno(1,2,3-cd)pyrene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l dibenzo(a,h)anthracene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l High-performance liquid chromatography method with fluorescence detection (HPLC-FLD) PN-EN ISO 17993:2005 z wylaczeniem pkt 8.1-8.4 SO-4/ZLGIG/WYK-04 ed. 1 z dn. 01.08.2025 PN-EN ISO 17993:2005 excluding pt 8.1-8.4 SO-4/ZLGIG/WYK-04 edition 1st of 01/08/2025","categories":["water"],"row_index":449,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Polycyclic aromatic hydrocarbons concentration (PAH): benzo(b)fluoranthene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(k)fluoranthene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(a)pyrene (2,0 – 30) ng/l (0,0020 - 0,030) µg/l benzo(g,h,i)perylene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l indeno(1,2,3-cd)pyrene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l dibenzo(a,h)anthracene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l High-performance liquid chromatography method with fluorescence detection (HPLC-FLD) PN-EN ISO 17993:2005 z wyłączeniem pkt 8.1-8.4 SO-4/ZLGIG/WYK-04 ed. 1 z dn. 01.08.2025 PN-EN ISO 17993:2005 excluding pt 8.1-8.4 SO-4/ZLGIG/WYK-04 edition 1st of 01/08/2025","search_zh":"水 Water PN-EN ISO 17993:2005 z wyłączeniem pkt 8.1-8.4 SO-4/ZLGIG/WYK-04 ed. 1 z dn. 01.08.2025 PN-EN ISO 17993:2005 excluding pt 8.1-8.4 SO-4/ZLGIG/WYK-04 edition 1st of 01/08/2025","test_object_zh":"水 Water"},{"_id":"6a5a55ef9af9f73f38250c5e","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda Water","test_object_en":"Water","methodology":"Suma wielopierścieniowych węglowodorów aromatycznych WWA (z obliczeń) Sum of polycyclic aromatic hydrocarbons (PAHs) (from calculations)","methodology_en":"Sum of polycyclic aromatic hydrocarbons (PAHs) (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma wielopierścieniowych węglowodorów aromatycznych WWA (z obliczeń) Sum of polycyclic aromatic hydrocarbons (PAHs) (from calculations)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Water Suma wielopierścieniowych węglowodorów aromatycznych WWA (z obliczeń) Sum of polycyclic aromatic hydrocarbons (PAHs) (from calculations) Woda Water Suma wielopierscieniowych weglowodorow aromatycznych WWA (z obliczen) Sum of polycyclic aromatic hydrocarbons (PAHs) (from calculations)","categories":["water"],"row_index":450,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Sum of polycyclic aromatic hydrocarbons (PAHs) (from calculations)","search_zh":"水 Water","test_object_zh":"水 Water"},{"_id":"6a5a55ef9af9f73f38250c5f","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Gleba, grunty Soil, grounds","test_object_en":"Soil, grounds","methodology":"Zawartość oleju mineralnego (węglowodory C - C ) 10 40 Zakres: (10,0 – 8000) mg/kg Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Mineral oil content (C - C hydrocarbons) 10 40 Range: (10,0 –8000) mg/kg Gas chromatography method with flame ionization detection(GC-FID)","methodology_en":"Mineral oil content (C - C hydrocarbons) 10 40 Range: (10,0 –8000) mg/kg Gas chromatography method with flame ionization detection(GC-FID)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość oleju mineralnego (węglowodory C - C ) 10 40 Zakres: (10,0 – 8000) mg/kg Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Mineral oil content (C - C hydrocarbons) 10 40 Range: (10,0 –8000) mg/kg Gas chromatography method with flame ionization detection(GC-FID)","reference":"PN-EN ISO 16703:2011","norm_bases":["PN-EN ISO 16703:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba, grunty Soil, grounds Zawartość oleju mineralnego (węglowodory C - C ) 10 40 Zakres: (10,0 – 8000) mg/kg Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Mineral oil content (C - C hydrocarbons) 10 40 Range: (10,0 –8000) mg/kg Gas chromatography method with flame ionization detection(GC-FID) PN-EN ISO 16703:2011 Gleba, grunty Soil, grounds Zawartosc oleju mineralnego (weglowodory C - C ) 10 40 Zakres: (10,0 – 8000) mg/kg Metoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Mineral oil content (C - C hydrocarbons) 10 40 Range: (10,0 –8000) mg/kg Gas chromatography method with flame ionization detection(GC-FID) PN-EN ISO 16703:2011","categories":["environment","petro"],"row_index":451,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil, grounds Mineral oil content (C - C hydrocarbons) 10 40 Range: (10,0 –8000) mg/kg Gas chromatography method with flame ionization detection(GC-FID) PN-EN ISO 16703:2011","search_zh":"土壤、土体 Soil, grounds PN-EN ISO 16703:2011","test_object_zh":"土壤、土体 Soil, grounds"},{"_id":"6a5a55ef9af9f73f38250c60","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Gleba, grunty Soil, grounds","test_object_en":"Soil, grounds","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA) Zakres: naftalen (0,10 – 50) mg/kg acenaften (0,10 – 50) mg/kg fluoren (0,10 – 50) mg/kg fenantren (0,10 – 50) mg/kg antracen (0,10 – 50) mg/kg fluoranten (0,10 – 50) mg/kg piren (0,10 – 50) mg/kg benzo(a)antracen (0,10 – 50) mg/kg chryzen (0,10 – 50) mg/kg benzo(b)fluoranten (0,10 – 50) mg/kg benzo(k)fluoranten (0,10 – 50) mg/kg benzo(a)piren (0,10 – 50) mg/kg dibenzo(a,h)antracen (0,10 – 50) mg/kg benzo(g,h,i)perylen (0,10 – 50) mg/kg indeno(1,2,3-cd)piren (0,10 – 50) mg/kg Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD Polycyclic aromatic hydrocarbons content(PAH) Range: naphthalene (0,10 – 50) mg/kg acenaphtene (0,10 – 50) mg/kg fluorene (0,10 – 50) mg/kg phenanthrene (0,10 – 50) mg/kg anthracene (0,10 – 50) mg/kg fluoranthene (0,10 – 50) mg/kg pyrene (0,10 – 50) mg/kg benzo(a)anthracene (0,10 – 50) mg/kg chrysene (0,10 – 50) mg/kg benzo(b)fluoranthene (0,10 – 50) mg/kg benzo(k)fluoranthene (0,10 – 50) mg/kg benzo(a)pyrene (0,10 – 50) mg/kg benzo(g,h,i)perylene (0,10 – 50) mg/kg indeno(1,2,3-cd)pyrene (0,10 – 50) mg/kg dibenzo(a,h)anthracene (0,10 – 50) mg/kg High-performance liquid chromatography method with fluorescence detection (HPLC-FLD)","methodology_en":"Polycyclic aromatic hydrocarbons content(PAH) Range: naphthalene (0,10 – 50) mg/kg acenaphtene (0,10 – 50) mg/kg fluorene (0,10 – 50) mg/kg phenanthrene (0,10 – 50) mg/kg anthracene (0,10 – 50) mg/kg fluoranthene (0,10 – 50) mg/kg pyrene (0,10 – 50) mg/kg benzo(a)anthracene (0,10 – 50) mg/kg chrysene (0,10 – 50) mg/kg benzo(b)fluoranthene (0,10 – 50) mg/kg benzo(k)fluoranthene (0,10 – 50) mg/kg benzo(a)pyrene (0,10 – 50) mg/kg benzo(g,h,i)perylene (0,10 – 50) mg/kg indeno(1,2,3-cd)pyrene (0,10 – 50) mg/kg dibenzo(a,h)anthracene (0,10 – 50) mg/kg High-performance liquid chromatography method with fluorescence detection (HPLC-FLD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA) Zakres: naftalen (0,10 – 50) mg/kg acenaften (0,10 – 50) mg/kg fluoren (0,10 – 50) mg/kg fenantren (0,10 – 50) mg/kg antracen (0,10 – 50) mg/kg fluoranten (0,10 – 50) mg/kg piren (0,10 – 50) mg/kg benzo(a)antracen (0,10 – 50) mg/kg chryzen (0,10 – 50) mg/kg benzo(b)fluoranten (0,10 – 50) mg/kg benzo(k)fluoranten (0,10 – 50) mg/kg benzo(a)piren (0,10 – 50) mg/kg dibenzo(a,h)antracen (0,10 – 50) mg/kg benzo(g,h,i)perylen (0,10 – 50) mg/kg indeno(1,2,3-cd)piren (0,10 – 50) mg/kg Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD Polycyclic aromatic hydrocarbons content(PAH) Range: naphthalene (0,10 – 50) mg/kg acenaphtene (0,10 – 50) mg/kg fluorene (0,10 – 50) mg/kg phenanthrene (0,10 – 50) mg/kg anthracene (0,10 – 50) mg/kg fluoranthene (0,10 – 50) mg/kg pyrene (0,10 – 50) mg/kg benzo(a)anthracene (0,10 – 50) mg/kg chrysene (0,10 – 50) mg/kg benzo(b)fluoranthene (0,10 – 50) mg/kg benzo(k)fluoranthene (0,10 – 50) mg/kg benzo(a)pyrene (0,10 – 50) mg/kg benzo(g,h,i)perylene (0,10 – 50) mg/kg indeno(1,2,3-cd)pyrene (0,10 – 50) mg/kg dibenzo(a,h)anthracene (0,10 – 50) mg/kg High-performance liquid chromatography method with fluorescence detection (HPLC-FLD)","reference":"PN-ISO 13877:2004","norm_bases":["PN-ISO 13877:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba, grunty Soil, grounds Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA) Zakres: naftalen (0,10 – 50) mg/kg acenaften (0,10 – 50) mg/kg fluoren (0,10 – 50) mg/kg fenantren (0,10 – 50) mg/kg antracen (0,10 – 50) mg/kg fluoranten (0,10 – 50) mg/kg piren (0,10 – 50) mg/kg benzo(a)antracen (0,10 – 50) mg/kg chryzen (0,10 – 50) mg/kg benzo(b)fluoranten (0,10 – 50) mg/kg benzo(k)fluoranten (0,10 – 50) mg/kg benzo(a)piren (0,10 – 50) mg/kg dibenzo(a,h)antracen (0,10 – 50) mg/kg benzo(g,h,i)perylen (0,10 – 50) mg/kg indeno(1,2,3-cd)piren (0,10 – 50) mg/kg Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD Polycyclic aromatic hydrocarbons content(PAH) Range: naphthalene (0,10 – 50) mg/kg acenaphtene (0,10 – 50) mg/kg fluorene (0,10 – 50) mg/kg phenanthrene (0,10 – 50) mg/kg anthracene (0,10 – 50) mg/kg fluoranthene (0,10 – 50) mg/kg pyrene (0,10 – 50) mg/kg benzo(a)anthracene (0,10 – 50) mg/kg chrysene (0,10 – 50) mg/kg benzo(b)fluoranthene (0,10 – 50) mg/kg benzo(k)fluoranthene (0,10 – 50) mg/kg benzo(a)pyrene (0,10 – 50) mg/kg benzo(g,h,i)perylene (0,10 – 50) mg/kg indeno(1,2,3-cd)pyrene (0,10 – 50) mg/kg dibenzo(a,h)anthracene (0,10 – 50) mg/kg High-performance liquid chromatography method with fluorescence detection (HPLC-FLD) PN-ISO 13877:2004 Gleba, grunty Soil, grounds Zawartosc wielopierscieniowych weglowodorow aromatycznych (WWA) Zakres: naftalen (0,10 – 50) mg/kg acenaften (0,10 – 50) mg/kg fluoren (0,10 – 50) mg/kg fenantren (0,10 – 50) mg/kg antracen (0,10 – 50) mg/kg fluoranten (0,10 – 50) mg/kg piren (0,10 – 50) mg/kg benzo(a)antracen (0,10 – 50) mg/kg chryzen (0,10 – 50) mg/kg benzo(b)fluoranten (0,10 – 50) mg/kg benzo(k)fluoranten (0,10 – 50) mg/kg benzo(a)piren (0,10 – 50) mg/kg dibenzo(a,h)antracen (0,10 – 50) mg/kg benzo(g,h,i)perylen (0,10 – 50) mg/kg indeno(1,2,3-cd)piren (0,10 – 50) mg/kg Metoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD Polycyclic aromatic hydrocarbons content(PAH) Range: naphthalene (0,10 – 50) mg/kg acenaphtene (0,10 – 50) mg/kg fluorene (0,10 – 50) mg/kg phenanthrene (0,10 – 50) mg/kg anthracene (0,10 – 50) mg/kg fluoranthene (0,10 – 50) mg/kg pyrene (0,10 – 50) mg/kg benzo(a)anthracene (0,10 – 50) mg/kg chrysene (0,10 – 50) mg/kg benzo(b)fluoranthene (0,10 – 50) mg/kg benzo(k)fluoranthene (0,10 – 50) mg/kg benzo(a)pyrene (0,10 – 50) mg/kg benzo(g,h,i)perylene (0,10 – 50) mg/kg indeno(1,2,3-cd)pyrene (0,10 – 50) mg/kg dibenzo(a,h)anthracene (0,10 – 50) mg/kg High-performance liquid chromatography method with fluorescence detection (HPLC-FLD) PN-ISO 13877:2004","categories":["environment"],"row_index":452,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil, grounds Polycyclic aromatic hydrocarbons content(PAH) Range: naphthalene (0,10 – 50) mg/kg acenaphtene (0,10 – 50) mg/kg fluorene (0,10 – 50) mg/kg phenanthrene (0,10 – 50) mg/kg anthracene (0,10 – 50) mg/kg fluoranthene (0,10 – 50) mg/kg pyrene (0,10 – 50) mg/kg benzo(a)anthracene (0,10 – 50) mg/kg chrysene (0,10 – 50) mg/kg benzo(b)fluoranthene (0,10 – 50) mg/kg benzo(k)fluoranthene (0,10 – 50) mg/kg benzo(a)pyrene (0,10 – 50) mg/kg benzo(g,h,i)perylene (0,10 – 50) mg/kg indeno(1,2,3-cd)pyrene (0,10 – 50) mg/kg dibenzo(a,h)anthracene (0,10 – 50) mg/kg High-performance liquid chromatography method with fluorescence detection (HPLC-FLD) PN-ISO 13877:2004","search_zh":"土壤、土体 Soil, grounds PN-ISO 13877:2004","test_object_zh":"土壤、土体 Soil, grounds"},{"_id":"6a5a55ef9af9f73f38250c61","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Gleba, grunty Soil, grounds","test_object_en":"Soil, grounds","methodology":"Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń) Sum of polycyclic aromatic hydrocarbons (PAH) (from calculations)","methodology_en":"Sum of polycyclic aromatic hydrocarbons (PAH) (calculated) Sum of polycyclic aromatic hydrocarbons (PAH) (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń) Sum of polycyclic aromatic hydrocarbons (PAH) (from calculations)","reference":"PN-ISO 13877:2004","norm_bases":["PN-ISO 13877:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba, grunty Soil, grounds Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń) Sum of polycyclic aromatic hydrocarbons (PAH) (from calculations) PN-ISO 13877:2004 Gleba, grunty Soil, grounds Suma wielopierscieniowych weglowodorow aromatycznych (WWA) (z obliczen) Sum of polycyclic aromatic hydrocarbons (PAH) (from calculations) PN-ISO 13877:2004","categories":["environment"],"row_index":453,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil, grounds Sum of polycyclic aromatic hydrocarbons (PAH) (calculated) Sum of polycyclic aromatic hydrocarbons (PAH) (from calculations) PN-ISO 13877:2004","search_zh":"土壤、土体 Soil, grounds PN-ISO 13877:2004","test_object_zh":"土壤、土体 Soil, grounds"},{"_id":"6a5a55ef9af9f73f38250c62","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Gleba, grunty Soil, grounds","test_object_en":"Soil, grounds","methodology":"Zawartość lotnych węglowodorów aromatycznych Zakres: benzen (0,040 – 20) mg/kg toluen (0,040 – 20) mg/kg etylobenzen (0,040 – 20) mg/kg o-ksylen (0,040 – 20) mg/kg styren (0,040 – 20) mg/kg m,p-ksylen (0,080 – 40) mg/kg Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) Volatile aromatic hydrocarbons content Range: benzene (0,040 – 20) mg/kg toluene (0,040 – 20) mg/kg ethylbenzene (0,040 – 20) mg/kg o-xylene (0,040 – 20) mg/kg styrene (0,040 – 20) mg/kg m,p-xylene (0,080 – 40) mg/kg Gas chromatography method with headspace analysis and mass spectrometry detection (HS-GC-MS)","methodology_en":"Volatile aromatic hydrocarbons content Range: benzene (0,040 – 20) mg/kg toluene (0,040 – 20) mg/kg ethylbenzene (0,040 – 20) mg/kg o-xylene (0,040 – 20) mg/kg styrene (0,040 – 20) mg/kg m,p-xylene (0,080 – 40) mg/kg Gas chromatography method with headspace analysis and mass spectrometry detection (HS-GC-MS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość lotnych węglowodorów aromatycznych Zakres: benzen (0,040 – 20) mg/kg toluen (0,040 – 20) mg/kg etylobenzen (0,040 – 20) mg/kg o-ksylen (0,040 – 20) mg/kg styren (0,040 – 20) mg/kg m,p-ksylen (0,080 – 40) mg/kg Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) Volatile aromatic hydrocarbons content Range: benzene (0,040 – 20) mg/kg toluene (0,040 – 20) mg/kg ethylbenzene (0,040 – 20) mg/kg o-xylene (0,040 – 20) mg/kg styrene (0,040 – 20) mg/kg m,p-xylene (0,080 – 40) mg/kg Gas chromatography method with headspace analysis and mass spectrometry detection (HS-GC-MS)","reference":"PN-EN ISO 22155:2016-07","norm_bases":["PN-EN ISO 22155:2016-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba, grunty Soil, grounds Zawartość lotnych węglowodorów aromatycznych Zakres: benzen (0,040 – 20) mg/kg toluen (0,040 – 20) mg/kg etylobenzen (0,040 – 20) mg/kg o-ksylen (0,040 – 20) mg/kg styren (0,040 – 20) mg/kg m,p-ksylen (0,080 – 40) mg/kg Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) Volatile aromatic hydrocarbons content Range: benzene (0,040 – 20) mg/kg toluene (0,040 – 20) mg/kg ethylbenzene (0,040 – 20) mg/kg o-xylene (0,040 – 20) mg/kg styrene (0,040 – 20) mg/kg m,p-xylene (0,080 – 40) mg/kg Gas chromatography method with headspace analysis and mass spectrometry detection (HS-GC-MS) PN-EN ISO 22155:2016-07 Gleba, grunty Soil, grounds Zawartosc lotnych weglowodorow aromatycznych Zakres: benzen (0,040 – 20) mg/kg toluen (0,040 – 20) mg/kg etylobenzen (0,040 – 20) mg/kg o-ksylen (0,040 – 20) mg/kg styren (0,040 – 20) mg/kg m,p-ksylen (0,080 – 40) mg/kg Metoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) Volatile aromatic hydrocarbons content Range: benzene (0,040 – 20) mg/kg toluene (0,040 – 20) mg/kg ethylbenzene (0,040 – 20) mg/kg o-xylene (0,040 – 20) mg/kg styrene (0,040 – 20) mg/kg m,p-xylene (0,080 – 40) mg/kg Gas chromatography method with headspace analysis and mass spectrometry detection (HS-GC-MS) PN-EN ISO 22155:2016-07","categories":["environment"],"row_index":454,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil, grounds Volatile aromatic hydrocarbons content Range: benzene (0,040 – 20) mg/kg toluene (0,040 – 20) mg/kg ethylbenzene (0,040 – 20) mg/kg o-xylene (0,040 – 20) mg/kg styrene (0,040 – 20) mg/kg m,p-xylene (0,080 – 40) mg/kg Gas chromatography method with headspace analysis and mass spectrometry detection (HS-GC-MS) PN-EN ISO 22155:2016-07","search_zh":"土壤、土体 Soil, grounds PN-EN ISO 22155:2016-07","test_object_zh":"土壤、土体 Soil, grounds"},{"_id":"6a5a55ef9af9f73f38250c63","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Gleba, grunty Soil, grounds","test_object_en":"Soil, grounds","methodology":"Suma lotnych węglowodorów aromatycznych (z obliczeń) Sum of volatile aromatic hydrocarbons (from calculations)","methodology_en":"Sum of volatile aromatic hydrocarbons (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma lotnych węglowodorów aromatycznych (z obliczeń) Sum of volatile aromatic hydrocarbons (from calculations)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba, grunty Soil, grounds Suma lotnych węglowodorów aromatycznych (z obliczeń) Sum of volatile aromatic hydrocarbons (from calculations) Gleba, grunty Soil, grounds Suma lotnych weglowodorow aromatycznych (z obliczen) Sum of volatile aromatic hydrocarbons (from calculations)","categories":["environment"],"row_index":455,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil, grounds Sum of volatile aromatic hydrocarbons (from calculations)","search_zh":"土壤、土体 Soil, grounds","test_object_zh":"土壤、土体 Soil, grounds"},{"_id":"6a5a55ef9af9f73f38250c64","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Szkło i ceramika do kontaktu z wodą przeznaczoną do spożycia przez ludzi Wyroby z tworzyw sztucznych i gumy do kontaktu z wodą przeznaczoną do spożycia przez ludzi Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption","test_object_en":"Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption","methodology":"Stężenie ogólnego węgla organicznego (OWO) po migracji Zakres: (0,20 – 20,0) mg/l Metoda wysokotemperaturowego spalania z detekcją IR Total organic carbon (TOC) concentration after migration Range: (0,20 – 20,0) mg/l High temp. combustion method with IR detection","methodology_en":"Total organic carbon (TOC) concentration after migration Range: (0,20 – 20,0) mg/l High temp. combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie ogólnego węgla organicznego (OWO) po migracji Zakres: (0,20 – 20,0) mg/l Metoda wysokotemperaturowego spalania z detekcją IR Total organic carbon (TOC) concentration after migration Range: (0,20 – 20,0) mg/l High temp. combustion method with IR detection","reference":"PN-EN 12873-1:2014-09 PN-EN 1484:1999","norm_bases":["PN-EN 12873-1:2014-09 PN-EN 1484:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Szkło i ceramika do kontaktu z wodą przeznaczoną do spożycia przez ludzi Wyroby z tworzyw sztucznych i gumy do kontaktu z wodą przeznaczoną do spożycia przez ludzi Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption Stężenie ogólnego węgla organicznego (OWO) po migracji Zakres: (0,20 – 20,0) mg/l Metoda wysokotemperaturowego spalania z detekcją IR Total organic carbon (TOC) concentration after migration Range: (0,20 – 20,0) mg/l High temp. combustion method with IR detection PN-EN 12873-1:2014-09 PN-EN 1484:1999 Szklo i ceramika do kontaktu z woda przeznaczona do spozycia przez ludzi Wyroby z tworzyw sztucznych i gumy do kontaktu z woda przeznaczona do spozycia przez ludzi Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption Stezenie ogolnego wegla organicznego (OWO) po migracji Zakres: (0,20 – 20,0) mg/l Metoda wysokotemperaturowego spalania z detekcja IR Total organic carbon (TOC) concentration after migration Range: (0,20 – 20,0) mg/l High temp. combustion method with IR detection PN-EN 12873-1:2014-09 PN-EN 1484:1999","categories":["materials","water"],"row_index":456,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption Total organic carbon (TOC) concentration after migration Range: (0,20 – 20,0) mg/l High temp. combustion method with IR detection PN-EN 12873-1:2014-09 PN-EN 1484:1999","search_zh":"与生活饮用水接触的玻璃与陶瓷；与生活饮用水接触的塑料与橡胶制品 Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption PN-EN 12873-1:2014-09 PN-EN 1484:1999","test_object_zh":"与生活饮用水接触的玻璃与陶瓷；与生活饮用水接触的塑料与橡胶制品 Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption"},{"_id":"6a5a55ef9af9f73f38250c65","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Szkło i ceramika do kontaktu z wodą przeznaczoną do spożycia przez ludzi Wyroby z tworzyw sztucznych i gumy do kontaktu z wodą przeznaczoną do spożycia przez ludzi Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption","test_object_en":"Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption","methodology":"Migracja (z obliczeń) Migration (from calculations)","methodology_en":"Migration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Migracja (z obliczeń) Migration (from calculations)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Szkło i ceramika do kontaktu z wodą przeznaczoną do spożycia przez ludzi Wyroby z tworzyw sztucznych i gumy do kontaktu z wodą przeznaczoną do spożycia przez ludzi Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption Migracja (z obliczeń) Migration (from calculations) Szklo i ceramika do kontaktu z woda przeznaczona do spozycia przez ludzi Wyroby z tworzyw sztucznych i gumy do kontaktu z woda przeznaczona do spozycia przez ludzi Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption Migracja (z obliczen) Migration (from calculations)","categories":["materials","water"],"row_index":457,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption Migration (calculated)","search_zh":"与生活饮用水接触的玻璃与陶瓷；与生活饮用水接触的塑料与橡胶制品 Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption","test_object_zh":"与生活饮用水接触的玻璃与陶瓷；与生活饮用水接触的塑料与橡胶制品 Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption"},{"_id":"6a5a55ef9af9f73f38250c66","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Szkło i ceramika do kontaktu z wodą przeznaczoną do spożycia przez ludzi Wyroby z tworzyw sztucznych i gumy do kontaktu z wodą przeznaczoną do spożycia przez ludzi Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption","test_object_en":"Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption","methodology":"Stężenie pierwiastków po migracji Zakres: As (0,0010 – 2,0) mg/l Cd (0,00005 – 2,0) mg/l Cr (0,0010 – 2,0) mg/l Ni (0,0020 – 2,0) mg/l Pb (0,0010 – 2,0) mg/l Metoda spektrometrii mas ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-MS) Elements concentration after migration Range: As (0,0010 – 2,0) mg/l Cd (0,00005 – 2,0) mg/l Cr (0,0010 – 2,0) mg/l Ni (0,0020 – 2,0) mg/l Pb (0,0010 – 2,0) mg/l Inductively coupled plasma mass spectrometry method (ICP-MS)","methodology_en":"Elements concentration after migration Range: As (0,0010 – 2,0) mg/l Cd (0,00005 – 2,0) mg/l Cr (0,0010 – 2,0) mg/l Ni (0,0020 – 2,0) mg/l Pb (0,0010 – 2,0) mg/l Inductively coupled plasma mass spectrometry method (ICP-MS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pierwiastków po migracji Zakres: As (0,0010 – 2,0) mg/l Cd (0,00005 – 2,0) mg/l Cr (0,0010 – 2,0) mg/l Ni (0,0020 – 2,0) mg/l Pb (0,0010 – 2,0) mg/l Metoda spektrometrii mas ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-MS) Elements concentration after migration Range: As (0,0010 – 2,0) mg/l Cd (0,00005 – 2,0) mg/l Cr (0,0010 – 2,0) mg/l Ni (0,0020 – 2,0) mg/l Pb (0,0010 – 2,0) mg/l Inductively coupled plasma mass spectrometry method (ICP-MS)","reference":"PN-EN 12873-1:2014-09 PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN 12873-1:2014-09 PN-EN ISO 17294-2:2024-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Szkło i ceramika do kontaktu z wodą przeznaczoną do spożycia przez ludzi Wyroby z tworzyw sztucznych i gumy do kontaktu z wodą przeznaczoną do spożycia przez ludzi Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption Stężenie pierwiastków po migracji Zakres: As (0,0010 – 2,0) mg/l Cd (0,00005 – 2,0) mg/l Cr (0,0010 – 2,0) mg/l Ni (0,0020 – 2,0) mg/l Pb (0,0010 – 2,0) mg/l Metoda spektrometrii mas ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-MS) Elements concentration after migration Range: As (0,0010 – 2,0) mg/l Cd (0,00005 – 2,0) mg/l Cr (0,0010 – 2,0) mg/l Ni (0,0020 – 2,0) mg/l Pb (0,0010 – 2,0) mg/l Inductively coupled plasma mass spectrometry method (ICP-MS) PN-EN 12873-1:2014-09 PN-EN ISO 17294-2:2024-04 Szklo i ceramika do kontaktu z woda przeznaczona do spozycia przez ludzi Wyroby z tworzyw sztucznych i gumy do kontaktu z woda przeznaczona do spozycia przez ludzi Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption Stezenie pierwiastkow po migracji Zakres: As (0,0010 – 2,0) mg/l Cd (0,00005 – 2,0) mg/l Cr (0,0010 – 2,0) mg/l Ni (0,0020 – 2,0) mg/l Pb (0,0010 – 2,0) mg/l Metoda spektrometrii mas ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-MS) Elements concentration after migration Range: As (0,0010 – 2,0) mg/l Cd (0,00005 – 2,0) mg/l Cr (0,0010 – 2,0) mg/l Ni (0,0020 – 2,0) mg/l Pb (0,0010 – 2,0) mg/l Inductively coupled plasma mass spectrometry method (ICP-MS) PN-EN 12873-1:2014-09 PN-EN ISO 17294-2:2024-04","categories":["materials","water"],"row_index":458,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption Elements concentration after migration Range: As (0,0010 – 2,0) mg/l Cd (0,00005 – 2,0) mg/l Cr (0,0010 – 2,0) mg/l Ni (0,0020 – 2,0) mg/l Pb (0,0010 – 2,0) mg/l Inductively coupled plasma mass spectrometry method (ICP-MS) PN-EN 12873-1:2014-09 PN-EN ISO 17294-2:2024-04","search_zh":"与生活饮用水接触的玻璃与陶瓷；与生活饮用水接触的塑料与橡胶制品 Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption PN-EN 12873-1:2014-09 PN-EN ISO 17294-2:2024-04","test_object_zh":"与生活饮用水接触的玻璃与陶瓷；与生活饮用水接触的塑料与橡胶制品 Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption"},{"_id":"6a5a55ef9af9f73f38250c67","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Szkło i ceramika do kontaktu z wodą przeznaczoną do spożycia przez ludzi Wyroby z tworzyw sztucznych i gumy do kontaktu z wodą przeznaczoną do spożycia przez ludzi Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption","test_object_en":"Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA) Zakres: benzo(b)fluoranten (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(k)fluoranten (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(a)piren (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(g,h,i)perylen (2,0 – 30) ng/l (0,0020 – 0,030) µg/l indeno(1,2,3-cd)piren (2,0 – 30) ng/l (0,0020 – 0,030) µg/l dibenzo(a,h)antracen (2,0 – 30) ng/l (0,0020 – 0,030) µg/l Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) Polycyclic aromatic hydrocarbons concentration (PAH) Range: benzo(b)fluoranthene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(k)fluoranthene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(a)pyrene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(g,h,i)perylene (2,0 – 30) ng/l (0,0020 - 0,030) µg/l indeno(1,2,3-cd)pyrene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l dibenzo(a,h)anthracene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l High-performance liquid chromatography method with fluorescence detection (HPLC-FLD)","methodology_en":"Polycyclic aromatic hydrocarbons concentration (PAH) Range: benzo(b)fluoranthene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(k)fluoranthene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(a)pyrene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(g,h,i)perylene (2,0 – 30) ng/l (0,0020 - 0,030) µg/l indeno(1,2,3-cd)pyrene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l dibenzo(a,h)anthracene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l High-performance liquid chromatography method with fluorescence detection (HPLC-FLD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA) Zakres: benzo(b)fluoranten (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(k)fluoranten (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(a)piren (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(g,h,i)perylen (2,0 – 30) ng/l (0,0020 – 0,030) µg/l indeno(1,2,3-cd)piren (2,0 – 30) ng/l (0,0020 – 0,030) µg/l dibenzo(a,h)antracen (2,0 – 30) ng/l (0,0020 – 0,030) µg/l Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) Polycyclic aromatic hydrocarbons concentration (PAH) Range: benzo(b)fluoranthene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(k)fluoranthene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(a)pyrene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(g,h,i)perylene (2,0 – 30) ng/l (0,0020 - 0,030) µg/l indeno(1,2,3-cd)pyrene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l dibenzo(a,h)anthracene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l High-performance liquid chromatography method with fluorescence detection (HPLC-FLD)","reference":"PN-EN 12873-1:2014-09 PN-EN ISO 17993:2005 z wyłączeniem pkt 8.1-8.4 SO-4/ZLGIG/WYK-04 ed. 1 z dn. 01.08.2025 PN-EN 12873-1:2014-09 PN-EN ISO 17993:2005 excluding pt 8.1-8.4 SO-4/ZLGIG/WYK-04 ed 1st of 01/08/2025","norm_bases":["PN-EN 12873-1:2014-09 PN-EN ISO 17993:2005 z wyłączeniem pkt 8.1-8.4 SO-4/ZLGIG/WYK-04 ed. 1 z dn. 01.08.2025 PN-EN 12873-1:2014-09 PN-EN ISO 17993:2005 excluding pt 8.1-8.4 SO-4/ZLGIG/WYK-04 ed 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Szkło i ceramika do kontaktu z wodą przeznaczoną do spożycia przez ludzi Wyroby z tworzyw sztucznych i gumy do kontaktu z wodą przeznaczoną do spożycia przez ludzi Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA) Zakres: benzo(b)fluoranten (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(k)fluoranten (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(a)piren (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(g,h,i)perylen (2,0 – 30) ng/l (0,0020 – 0,030) µg/l indeno(1,2,3-cd)piren (2,0 – 30) ng/l (0,0020 – 0,030) µg/l dibenzo(a,h)antracen (2,0 – 30) ng/l (0,0020 – 0,030) µg/l Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) Polycyclic aromatic hydrocarbons concentration (PAH) Range: benzo(b)fluoranthene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(k)fluoranthene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(a)pyrene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(g,h,i)perylene (2,0 – 30) ng/l (0,0020 - 0,030) µg/l indeno(1,2,3-cd)pyrene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l dibenzo(a,h)anthracene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l High-performance liquid chromatography method with fluorescence detection (HPLC-FLD) PN-EN 12873-1:2014-09 PN-EN ISO 17993:2005 z wyłączeniem pkt 8.1-8.4 SO-4/ZLGIG/WYK-04 ed. 1 z dn. 01.08.2025 PN-EN 12873-1:2014-09 PN-EN ISO 17993:2005 excluding pt 8.1-8.4 SO-4/ZLGIG/WYK-04 ed 1st of 01/08/2025 Szklo i ceramika do kontaktu z woda przeznaczona do spozycia przez ludzi Wyroby z tworzyw sztucznych i gumy do kontaktu z woda przeznaczona do spozycia przez ludzi Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption Stezenie wielopierscieniowych weglowodorow aromatycznych (WWA) Zakres: benzo(b)fluoranten (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(k)fluoranten (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(a)piren (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(g,h,i)perylen (2,0 – 30) ng/l (0,0020 – 0,030) µg/l indeno(1,2,3-cd)piren (2,0 – 30) ng/l (0,0020 – 0,030) µg/l dibenzo(a,h)antracen (2,0 – 30) ng/l (0,0020 – 0,030) µg/l Metoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) Polycyclic aromatic hydrocarbons concentration (PAH) Range: benzo(b)fluoranthene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(k)fluoranthene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(a)pyrene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(g,h,i)perylene (2,0 – 30) ng/l (0,0020 - 0,030) µg/l indeno(1,2,3-cd)pyrene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l dibenzo(a,h)anthracene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l High-performance liquid chromatography method with fluorescence detection (HPLC-FLD) PN-EN 12873-1:2014-09 PN-EN ISO 17993:2005 z wylaczeniem pkt 8.1-8.4 SO-4/ZLGIG/WYK-04 ed. 1 z dn. 01.08.2025 PN-EN 12873-1:2014-09 PN-EN ISO 17993:2005 excluding pt 8.1-8.4 SO-4/ZLGIG/WYK-04 ed 1st of 01/08/2025","categories":["materials","water"],"row_index":459,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption Polycyclic aromatic hydrocarbons concentration (PAH) Range: benzo(b)fluoranthene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(k)fluoranthene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(a)pyrene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l benzo(g,h,i)perylene (2,0 – 30) ng/l (0,0020 - 0,030) µg/l indeno(1,2,3-cd)pyrene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l dibenzo(a,h)anthracene (2,0 – 30) ng/l (0,0020 – 0,030) µg/l High-performance liquid chromatography method with fluorescence detection (HPLC-FLD) PN-EN 12873-1:2014-09 PN-EN ISO 17993:2005 z wyłączeniem pkt 8.1-8.4 SO-4/ZLGIG/WYK-04 ed. 1 z dn. 01.08.2025 PN-EN 12873-1:2014-09 PN-EN ISO 17993:2005 excluding pt 8.1-8.4 SO-4/ZLGIG/WYK-04 ed 1st of 01/08/2025","search_zh":"与生活饮用水接触的玻璃与陶瓷；与生活饮用水接触的塑料与橡胶制品 Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption PN-EN 12873-1:2014-09 PN-EN ISO 17993:2005 z wyłączeniem pkt 8.1-8.4 SO-4/ZLGIG/WYK-04 ed. 1 z dn. 01.08.2025 PN-EN 12873-1:2014-09 PN-EN ISO 17993:2005 excluding pt 8.1-8.4 SO-4/ZLGIG/WYK-04 ed 1st of 01/08/2025","test_object_zh":"与生活饮用水接触的玻璃与陶瓷；与生活饮用水接触的塑料与橡胶制品 Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption"},{"_id":"6a5a55ef9af9f73f38250c68","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Szkło i ceramika do kontaktu z wodą przeznaczoną do spożycia przez ludzi Wyroby z tworzyw sztucznych i gumy do kontaktu z wodą przeznaczoną do spożycia przez ludzi Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption","test_object_en":"Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption","methodology":"Suma wielopierścieniowych węglowodorów aromatycznych WWA (z obliczeń) Sum of polycyclic aromatic hydrocarbons (PAH) (from calculations)","methodology_en":"Sum of polycyclic aromatic hydrocarbons (PAH) (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma wielopierścieniowych węglowodorów aromatycznych WWA (z obliczeń) Sum of polycyclic aromatic hydrocarbons (PAH) (from calculations)","reference":"PN-EN 12873-1:2014-09 PN-EN ISO 17993:2005 excluding pt. 8.1-8.4 SO-4/ZLGIG/WYK-04 ed 1st of 01/08/2025","norm_bases":["PN-EN 12873-1:2014-09 PN-EN ISO 17993:2005 excluding pt. 8.1-8.4 SO-4/ZLGIG/WYK-04 ed 1st of 01/08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Szkło i ceramika do kontaktu z wodą przeznaczoną do spożycia przez ludzi Wyroby z tworzyw sztucznych i gumy do kontaktu z wodą przeznaczoną do spożycia przez ludzi Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption Suma wielopierścieniowych węglowodorów aromatycznych WWA (z obliczeń) Sum of polycyclic aromatic hydrocarbons (PAH) (from calculations) PN-EN 12873-1:2014-09 PN-EN ISO 17993:2005 excluding pt. 8.1-8.4 SO-4/ZLGIG/WYK-04 ed 1st of 01/08/2025 Szklo i ceramika do kontaktu z woda przeznaczona do spozycia przez ludzi Wyroby z tworzyw sztucznych i gumy do kontaktu z woda przeznaczona do spozycia przez ludzi Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption Suma wielopierscieniowych weglowodorow aromatycznych WWA (z obliczen) Sum of polycyclic aromatic hydrocarbons (PAH) (from calculations) PN-EN 12873-1:2014-09 PN-EN ISO 17993:2005 excluding pt. 8.1-8.4 SO-4/ZLGIG/WYK-04 ed 1st of 01/08/2025","categories":["materials","water"],"row_index":460,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption Sum of polycyclic aromatic hydrocarbons (PAH) (from calculations) PN-EN 12873-1:2014-09 PN-EN ISO 17993:2005 excluding pt. 8.1-8.4 SO-4/ZLGIG/WYK-04 ed 1st of 01/08/2025","search_zh":"与生活饮用水接触的玻璃与陶瓷；与生活饮用水接触的塑料与橡胶制品 Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption PN-EN 12873-1:2014-09 PN-EN ISO 17993:2005 excluding pt. 8.1-8.4 SO-4/ZLGIG/WYK-04 ed 1st of 01/08/2025","test_object_zh":"与生活饮用水接触的玻璃与陶瓷；与生活饮用水接触的塑料与橡胶制品 Glass and ceramic products intended to come into contact with water for human consumption Products made from plastic and rubber intended to come into contact with water for human consumption"},{"_id":"6a5a55ef9af9f73f38250c69","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Woda E Water","test_object_en":"Water E","methodology":"Stężenie pierwiastków Metoda spektrometrii mas ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-MS) Elements concentration Inductively coupled plasma mass spectrometry method (ICP-MS)","methodology_en":"Elements concentration Inductively coupled plasma mass spectrometry method (ICP-MS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pierwiastków Metoda spektrometrii mas ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-MS) Elements concentration Inductively coupled plasma mass spectrometry method (ICP-MS)","reference":"PN-EN ISO 17294-2","norm_bases":["PN-EN ISO 17294-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda E Water Stężenie pierwiastków Metoda spektrometrii mas ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-MS) Elements concentration Inductively coupled plasma mass spectrometry method (ICP-MS) PN-EN ISO 17294-2 Woda E Water Stezenie pierwiastkow Metoda spektrometrii mas ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-MS) Elements concentration Inductively coupled plasma mass spectrometry method (ICP-MS) PN-EN ISO 17294-2","categories":["water"],"row_index":461,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water E Elements concentration Inductively coupled plasma mass spectrometry method (ICP-MS) PN-EN ISO 17294-2"},{"_id":"6a5a55ef9af9f73f38250c6a","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, węgiel brunatny Solid fuels: hard coal, brown coal","test_object_en":"Solid fuels: hard coal, brown coal","methodology":"Zawartość siarki pirytowej Zakres: (0,01 – 5,40) % Metoda wagowa Pyritic sulphat content Range: (0,01 – 5,40) % Weight method","methodology_en":"Pyritic sulphat content Range: (0,01 – 5,40) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość siarki pirytowej Zakres: (0,01 – 5,40) % Metoda wagowa Pyritic sulphat content Range: (0,01 – 5,40) % Weight method","reference":"PN-G-04582:1997","norm_bases":["PN-G-04582:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, węgiel brunatny Solid fuels: hard coal, brown coal Zawartość siarki pirytowej Zakres: (0,01 – 5,40) % Metoda wagowa Pyritic sulphat content Range: (0,01 – 5,40) % Weight method PN-G-04582:1997 Paliwa stale: wegiel kamienny, wegiel brunatny Solid fuels: hard coal, brown coal Zawartosc siarki pirytowej Zakres: (0,01 – 5,40) % Metoda wagowa Pyritic sulphat content Range: (0,01 – 5,40) % Weight method PN-G-04582:1997","categories":["petro"],"row_index":462,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal, brown coal Pyritic sulphat content Range: (0,01 – 5,40) % Weight method PN-G-04582:1997","search_zh":"固体燃料：烟煤、褐煤 Solid fuels: hard coal, brown coal PN-G-04582:1997","test_object_zh":"固体燃料：烟煤、褐煤 Solid fuels: hard coal, brown coal"},{"_id":"6a5a55ef9af9f73f38250c6b","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, węgiel brunatny Solid fuels: hard coal, brown coal","test_object_en":"Solid fuels: hard coal, brown coal","methodology":"Zawartość siarki siarczanowej Zakres: (0,01 – 1,60) % Metoda wagowa Sulphate sulphur content Range: (0,01 – 1,60) % Weight method","methodology_en":"Sulphate sulphur content Range: (0,01 – 1,60) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość siarki siarczanowej Zakres: (0,01 – 1,60) % Metoda wagowa Sulphate sulphur content Range: (0,01 – 1,60) % Weight method","reference":"PN-G-04582:1997","norm_bases":["PN-G-04582:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, węgiel brunatny Solid fuels: hard coal, brown coal Zawartość siarki siarczanowej Zakres: (0,01 – 1,60) % Metoda wagowa Sulphate sulphur content Range: (0,01 – 1,60) % Weight method PN-G-04582:1997 Paliwa stale: wegiel kamienny, wegiel brunatny Solid fuels: hard coal, brown coal Zawartosc siarki siarczanowej Zakres: (0,01 – 1,60) % Metoda wagowa Sulphate sulphur content Range: (0,01 – 1,60) % Weight method PN-G-04582:1997","categories":["petro"],"row_index":463,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal, brown coal Sulphate sulphur content Range: (0,01 – 1,60) % Weight method PN-G-04582:1997","search_zh":"固体燃料：烟煤、褐煤 Solid fuels: hard coal, brown coal PN-G-04582:1997","test_object_zh":"固体燃料：烟煤、褐煤 Solid fuels: hard coal, brown coal"},{"_id":"6a5a55ef9af9f73f38250c6c","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, węgiel brunatny Solid fuels: hard coal, brown coal","test_object_en":"Solid fuels: hard coal, brown coal","methodology":"Zawartość gęstości rzeczywistej Zakres: (1,275 – 2,675) g/cm3 Metoda piknometryczna The true relative density content Range: (1,275 – 2,675) g/cm3 Pycnometric method","methodology_en":"The true relative density content Range: (1,275 – 2,675) g/cm3 Pycnometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość gęstości rzeczywistej Zakres: (1,275 – 2,675) g/cm3 Metoda piknometryczna The true relative density content Range: (1,275 – 2,675) g/cm3 Pycnometric method","reference":"PN-G-04537:1998","norm_bases":["PN-G-04537:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, węgiel brunatny Solid fuels: hard coal, brown coal Zawartość gęstości rzeczywistej Zakres: (1,275 – 2,675) g/cm3 Metoda piknometryczna The true relative density content Range: (1,275 – 2,675) g/cm3 Pycnometric method PN-G-04537:1998 Paliwa stale: wegiel kamienny, wegiel brunatny Solid fuels: hard coal, brown coal Zawartosc gestosci rzeczywistej Zakres: (1,275 – 2,675) g/cm3 Metoda piknometryczna The true relative density content Range: (1,275 – 2,675) g/cm3 Pycnometric method PN-G-04537:1998","categories":["petro"],"row_index":464,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal, brown coal The true relative density content Range: (1,275 – 2,675) g/cm3 Pycnometric method PN-G-04537:1998","search_zh":"固体燃料：烟煤、褐煤 Solid fuels: hard coal, brown coal PN-G-04537:1998","test_object_zh":"固体燃料：烟煤、褐煤 Solid fuels: hard coal, brown coal"},{"_id":"6a5a55ef9af9f73f38250c6d","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, węgiel brunatny Solid fuels: hard coal, brown coal","test_object_en":"Solid fuels: hard coal, brown coal","methodology":"Zawartość chloru Zakres: (0,043 – 0,640) % Metoda miareczkowa Chlorine content Range: (0,043 – 0,640) % Titration method","methodology_en":"Chlorine content Range: (0,043 – 0,640) % Titration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość chloru Zakres: (0,043 – 0,640) % Metoda miareczkowa Chlorine content Range: (0,043 – 0,640) % Titration method","reference":"SW/ZLGIG/PB-13 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-13, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-13 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-13, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, węgiel brunatny Solid fuels: hard coal, brown coal Zawartość chloru Zakres: (0,043 – 0,640) % Metoda miareczkowa Chlorine content Range: (0,043 – 0,640) % Titration method SW/ZLGIG/PB-13 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-13, 2nd edition of 18 August 2025 Paliwa stale: wegiel kamienny, wegiel brunatny Solid fuels: hard coal, brown coal Zawartosc chloru Zakres: (0,043 – 0,640) % Metoda miareczkowa Chlorine content Range: (0,043 – 0,640) % Titration method SW/ZLGIG/PB-13 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-13, 2nd edition of 18 August 2025","categories":["petro"],"row_index":465,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal, brown coal Chlorine content Range: (0,043 – 0,640) % Titration method SW/ZLGIG/PB-13 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-13, 2nd edition of 18 August 2025","search_zh":"固体燃料：烟煤、褐煤 Solid fuels: hard coal, brown coal SW/ZLGIG/PB-13 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-13, 2nd edition of 18 August 2025","test_object_zh":"固体燃料：烟煤、褐煤 Solid fuels: hard coal, brown coal"},{"_id":"6a5a55ef9af9f73f38250c6e","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, węgiel brunatny Solid fuels: hard coal, brown coal","test_object_en":"Solid fuels: hard coal, brown coal","methodology":"Zawartość chloru Zakres: (0,005 – 1,100) % Metoda wysokotemperaturowego spalania z detekcją kulometryczną Chlorine content Range: (0,005 - 1,100) % High-temperature combustion method with coulometric detection","methodology_en":"Chlorine content Range: (0,005 - 1,100) % High-temperature combustion method with coulometric detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość chloru Zakres: (0,005 – 1,100) % Metoda wysokotemperaturowego spalania z detekcją kulometryczną Chlorine content Range: (0,005 - 1,100) % High-temperature combustion method with coulometric detection","reference":"SW/ZLGIG/PB-12 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-12, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-12 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-12, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, węgiel brunatny Solid fuels: hard coal, brown coal Zawartość chloru Zakres: (0,005 – 1,100) % Metoda wysokotemperaturowego spalania z detekcją kulometryczną Chlorine content Range: (0,005 - 1,100) % High-temperature combustion method with coulometric detection SW/ZLGIG/PB-12 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-12, 2nd edition of 18 August 2025 Paliwa stale: wegiel kamienny, wegiel brunatny Solid fuels: hard coal, brown coal Zawartosc chloru Zakres: (0,005 – 1,100) % Metoda wysokotemperaturowego spalania z detekcja kulometryczna Chlorine content Range: (0,005 - 1,100) % High-temperature combustion method with coulometric detection SW/ZLGIG/PB-12 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-12, 2nd edition of 18 August 2025","categories":["petro"],"row_index":466,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal, brown coal Chlorine content Range: (0,005 - 1,100) % High-temperature combustion method with coulometric detection SW/ZLGIG/PB-12 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-12, 2nd edition of 18 August 2025","search_zh":"固体燃料：烟煤、褐煤 Solid fuels: hard coal, brown coal SW/ZLGIG/PB-12 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-12, 2nd edition of 18 August 2025","test_object_zh":"固体燃料：烟煤、褐煤 Solid fuels: hard coal, brown coal"},{"_id":"6a5a55ef9af9f73f38250c6f","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel brunatny Solid fuels: brown coal","test_object_en":"Solid fuels: brown coal","methodology":"Zawartość wilgoci w próbce analitycznej (wilgoć w próbce do analizy) Zakres: (5,50 – 10,20) % Metoda wagowa Moisture content in the analytical sample (moisture in the sample for analysis) Range: (5,50 – 10,20) % Weight method","methodology_en":"Moisture content in the analytical sample (moisture in the sample for analysis) Range: (5,50 – 10,20) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej (wilgoć w próbce do analizy) Zakres: (5,50 – 10,20) % Metoda wagowa Moisture content in the analytical sample (moisture in the sample for analysis) Range: (5,50 – 10,20) % Weight method","reference":"PN-ISO 5068:2004","norm_bases":["PN-ISO 5068:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel brunatny Solid fuels: brown coal Zawartość wilgoci w próbce analitycznej (wilgoć w próbce do analizy) Zakres: (5,50 – 10,20) % Metoda wagowa Moisture content in the analytical sample (moisture in the sample for analysis) Range: (5,50 – 10,20) % Weight method PN-ISO 5068:2004 Paliwa stale: wegiel brunatny Solid fuels: brown coal Zawartosc wilgoci w probce analitycznej (wilgoc w probce do analizy) Zakres: (5,50 – 10,20) % Metoda wagowa Moisture content in the analytical sample (moisture in the sample for analysis) Range: (5,50 – 10,20) % Weight method PN-ISO 5068:2004","categories":["petro"],"row_index":467,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: brown coal Moisture content in the analytical sample (moisture in the sample for analysis) Range: (5,50 – 10,20) % Weight method PN-ISO 5068:2004"},{"_id":"6a5a55ef9af9f73f38250c70","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Sampling for chemical and physical analysis","methodology_en":"Sampling for chemical and physical analysis","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Sampling for chemical and physical analysis","reference":"PN-G-04502:2014-11 pkt 5.3.1.2","norm_bases":["PN-G-04502:2014-11 pkt 5.3.1.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Pobieranie próbek do badań chemicznych i fizycznych Sampling for chemical and physical analysis PN-G-04502:2014-11 pkt 5.3.1.2 Paliwa stale: wegiel kamienny Solid fuels: hard coal Pobieranie probek do badan chemicznych i fizycznych Sampling for chemical and physical analysis PN-G-04502:2014-11 pkt 5.3.1.2","categories":["petro"],"row_index":468,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Sampling for chemical and physical analysis PN-G-04502:2014-11 pkt 5.3.1.2","search_zh":"固体燃料：烟煤 PN-G-04502:2014-11 pkt 5.3.1.2","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ef9af9f73f38250c71","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Zdolność spiekania Zakres: 0 – 90 Metoda Rogi Caking power Range: 0 – 90 Roga method","methodology_en":"Caking power Range: 0 – 90 Roga method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność spiekania Zakres: 0 – 90 Metoda Rogi Caking power Range: 0 – 90 Roga method","reference":"PN-G-04508:2020-05","norm_bases":["PN-G-04508:2020-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Zdolność spiekania Zakres: 0 – 90 Metoda Rogi Caking power Range: 0 – 90 Roga method PN-G-04508:2020-05 Paliwa stale: wegiel kamienny Solid fuels: hard coal Zdolnosc spiekania Zakres: 0 – 90 Metoda Rogi Caking power Range: 0 – 90 Roga method PN-G-04508:2020-05","categories":["petro"],"row_index":469,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Caking power Range: 0 – 90 Roga method PN-G-04508:2020-05","search_zh":"固体燃料：烟煤 PN-G-04508:2020-05","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ef9af9f73f38250c72","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Wskaźnik wolnego wydymania SI Zakres: 0 – 9 Metoda optyczna Crucible swelling number Range: 0 – 9 Optical method","methodology_en":"Crucible swelling number Range: 0 – 9 Optical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik wolnego wydymania SI Zakres: 0 – 9 Metoda optyczna Crucible swelling number Range: 0 – 9 Optical method","reference":"PN-ISO 501:2007","norm_bases":["PN-ISO 501:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Wskaźnik wolnego wydymania SI Zakres: 0 – 9 Metoda optyczna Crucible swelling number Range: 0 – 9 Optical method PN-ISO 501:2007 Paliwa stale: wegiel kamienny Solid fuels: hard coal Wskaznik wolnego wydymania SI Zakres: 0 – 9 Metoda optyczna Crucible swelling number Range: 0 – 9 Optical method PN-ISO 501:2007","categories":["petro"],"row_index":470,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Crucible swelling number Range: 0 – 9 Optical method PN-ISO 501:2007","search_zh":"固体燃料：烟煤 PN-ISO 501:2007","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ef9af9f73f38250c73","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Wskaźniki dylatometryczne Zakres: a (10 – 35) % b (-20 – 300) % Temperatura (330 – 550) oC Metoda Audibert – Arnu Dilatometric indices Range: a (10 – 35) % b (-20 – 300) % Temperature (330 – 550) oC Audibert-Arnu dilatometer method","methodology_en":"Dilatometric indices Range: a (10 – 35) % b (-20 – 300) % Temperature (330 – 550) oC Audibert-Arnu dilatometer method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźniki dylatometryczne Zakres: a (10 – 35) % b (-20 – 300) % Temperatura (330 – 550) oC Metoda Audibert – Arnu Dilatometric indices Range: a (10 – 35) % b (-20 – 300) % Temperature (330 – 550) oC Audibert-Arnu dilatometer method","reference":"PN-81/G-04517","norm_bases":["PN-81/G-04517"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Wskaźniki dylatometryczne Zakres: a (10 – 35) % b (-20 – 300) % Temperatura (330 – 550) oC Metoda Audibert – Arnu Dilatometric indices Range: a (10 – 35) % b (-20 – 300) % Temperature (330 – 550) oC Audibert-Arnu dilatometer method PN-81/G-04517 Paliwa stale: wegiel kamienny Solid fuels: hard coal Wskazniki dylatometryczne Zakres: a (10 – 35) % b (-20 – 300) % Temperatura (330 – 550) oC Metoda Audibert – Arnu Dilatometric indices Range: a (10 – 35) % b (-20 – 300) % Temperature (330 – 550) oC Audibert-Arnu dilatometer method PN-81/G-04517","categories":["petro"],"row_index":471,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Dilatometric indices Range: a (10 – 35) % b (-20 – 300) % Temperature (330 – 550) oC Audibert-Arnu dilatometer method PN-81/G-04517","search_zh":"固体燃料：烟煤 PN-81/G-04517","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ef9af9f73f38250c74","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Wskaźnik plastyczności Zakres: (3 – 29 400) ddpm Metoda Gieselera Plastic properties indices Range: (3 – 29 400) ddpm Gieseler method","methodology_en":"Plastic properties indices Range: (3 – 29 400) ddpm Gieseler method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik plastyczności Zakres: (3 – 29 400) ddpm Metoda Gieselera Plastic properties indices Range: (3 – 29 400) ddpm Gieseler method","reference":"PN-G-04565:1994","norm_bases":["PN-G-04565:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Wskaźnik plastyczności Zakres: (3 – 29 400) ddpm Metoda Gieselera Plastic properties indices Range: (3 – 29 400) ddpm Gieseler method PN-G-04565:1994 Paliwa stale: wegiel kamienny Solid fuels: hard coal Wskaznik plastycznosci Zakres: (3 – 29 400) ddpm Metoda Gieselera Plastic properties indices Range: (3 – 29 400) ddpm Gieseler method PN-G-04565:1994","categories":["petro","materials"],"row_index":472,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Plastic properties indices Range: (3 – 29 400) ddpm Gieseler method PN-G-04565:1994","search_zh":"固体燃料：烟煤 PN-G-04565:1994","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ef9af9f73f38250c75","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Wskaźniki plastometryczne Zakres: x 8 mm – 42 mm Y 5 mm – 21 mm Metoda Sapożnikowa Plastometric indices Range: x 8 mm – 42 mm Y 5 mm – 21 mm Sapoznikow method","methodology_en":"Plastometric indices Range: x 8 mm – 42 mm Y 5 mm – 21 mm Sapoznikow method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźniki plastometryczne Zakres: x 8 mm – 42 mm Y 5 mm – 21 mm Metoda Sapożnikowa Plastometric indices Range: x 8 mm – 42 mm Y 5 mm – 21 mm Sapoznikow method","reference":"PN-88/G-04545","norm_bases":["PN-88/G-04545"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Wskaźniki plastometryczne Zakres: x 8 mm – 42 mm Y 5 mm – 21 mm Metoda Sapożnikowa Plastometric indices Range: x 8 mm – 42 mm Y 5 mm – 21 mm Sapoznikow method PN-88/G-04545 Paliwa stale: wegiel kamienny Solid fuels: hard coal Wskazniki plastometryczne Zakres: x 8 mm – 42 mm Y 5 mm – 21 mm Metoda Sapoznikowa Plastometric indices Range: x 8 mm – 42 mm Y 5 mm – 21 mm Sapoznikow method PN-88/G-04545","categories":["petro"],"row_index":473,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Plastometric indices Range: x 8 mm – 42 mm Y 5 mm – 21 mm Sapoznikow method PN-88/G-04545","search_zh":"固体燃料：烟煤 PN-88/G-04545","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ef9af9f73f38250c76","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Ciśnienie rozprężania w stałej objętości Zakres: P (0,04 – 0,42) kG/cm2 max Metoda manometryczna Expension pressure in constant volume Range: P (0,04 – 0,42) kG/cm2 max Manometric method","methodology_en":"Expension pressure in constant volume Range: P (0,04 – 0,42) kG/cm2 max Manometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciśnienie rozprężania w stałej objętości Zakres: P (0,04 – 0,42) kG/cm2 max Metoda manometryczna Expension pressure in constant volume Range: P (0,04 – 0,42) kG/cm2 max Manometric method","reference":"PN-73/G-04522","norm_bases":["PN-73/G-04522"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Ciśnienie rozprężania w stałej objętości Zakres: P (0,04 – 0,42) kG/cm2 max Metoda manometryczna Expension pressure in constant volume Range: P (0,04 – 0,42) kG/cm2 max Manometric method PN-73/G-04522 Paliwa stale: wegiel kamienny Solid fuels: hard coal Cisnienie rozprezania w stalej objetosci Zakres: P (0,04 – 0,42) kG/cm2 max Metoda manometryczna Expension pressure in constant volume Range: P (0,04 – 0,42) kG/cm2 max Manometric method PN-73/G-04522","categories":["petro","metrology"],"row_index":474,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Expension pressure in constant volume Range: P (0,04 – 0,42) kG/cm2 max Manometric method PN-73/G-04522","search_zh":"固体燃料：烟煤 PN-73/G-04522","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ef9af9f73f38250c77","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Podatność przemiałowa Zakres: 25 – 100 Metoda Hardgrove’a Hardgrove grindability index Range: 25 – 100 Hardgrove method","methodology_en":"Hardgrove grindability index Range: 25 – 100 Hardgrove method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Podatność przemiałowa Zakres: 25 – 100 Metoda Hardgrove’a Hardgrove grindability index Range: 25 – 100 Hardgrove method","reference":"PN-ISO 5074:2002","norm_bases":["PN-ISO 5074:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Podatność przemiałowa Zakres: 25 – 100 Metoda Hardgrove’a Hardgrove grindability index Range: 25 – 100 Hardgrove method PN-ISO 5074:2002 Paliwa stale: wegiel kamienny Solid fuels: hard coal Podatnosc przemialowa Zakres: 25 – 100 Metoda Hardgrove’a Hardgrove grindability index Range: 25 – 100 Hardgrove method PN-ISO 5074:2002","categories":["petro"],"row_index":475,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Hardgrove grindability index Range: 25 – 100 Hardgrove method PN-ISO 5074:2002","search_zh":"固体燃料：烟煤 PN-ISO 5074:2002","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ef9af9f73f38250c78","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Refleksyjność witrynitu Zakres: (0,40 – 2,85) % Metoda mikroskopowa Reflectance of vitrinite Range: (0,40 – 2,85) % Microcope method","methodology_en":"Reflectance of vitrinite Range: (0,40 – 2,85) % Microcope method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Refleksyjność witrynitu Zakres: (0,40 – 2,85) % Metoda mikroskopowa Reflectance of vitrinite Range: (0,40 – 2,85) % Microcope method","reference":"PN-ISO 7404-5:2002","norm_bases":["PN-ISO 7404-5:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Refleksyjność witrynitu Zakres: (0,40 – 2,85) % Metoda mikroskopowa Reflectance of vitrinite Range: (0,40 – 2,85) % Microcope method PN-ISO 7404-5:2002 Paliwa stale: wegiel kamienny Solid fuels: hard coal Refleksyjnosc witrynitu Zakres: (0,40 – 2,85) % Metoda mikroskopowa Reflectance of vitrinite Range: (0,40 – 2,85) % Microcope method PN-ISO 7404-5:2002","categories":["petro"],"row_index":476,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Reflectance of vitrinite Range: (0,40 – 2,85) % Microcope method PN-ISO 7404-5:2002","search_zh":"固体燃料：烟煤 PN-ISO 7404-5:2002","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ef9af9f73f38250c79","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość grup macerałów Zakres: (1 – 85) % Metoda mikroskopowa Maceral group composition Range: (1 – 85) % Microcope method","methodology_en":"Maceral group composition Range: (1 – 85) % Microcope method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość grup macerałów Zakres: (1 – 85) % Metoda mikroskopowa Maceral group composition Range: (1 – 85) % Microcope method","reference":"PN-ISO 7404-3:2001","norm_bases":["PN-ISO 7404-3:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Zawartość grup macerałów Zakres: (1 – 85) % Metoda mikroskopowa Maceral group composition Range: (1 – 85) % Microcope method PN-ISO 7404-3:2001 Paliwa stale: wegiel kamienny Solid fuels: hard coal Zawartosc grup maceralow Zakres: (1 – 85) % Metoda mikroskopowa Maceral group composition Range: (1 – 85) % Microcope method PN-ISO 7404-3:2001","categories":["petro"],"row_index":477,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Maceral group composition Range: (1 – 85) % Microcope method PN-ISO 7404-3:2001","search_zh":"固体燃料：烟煤 PN-ISO 7404-3:2001","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ef9af9f73f38250c7a","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Wskaźnik fixed carbon (z obliczeń) Fixed carbon indices (from calculations)","methodology_en":"Fixed carbon indices (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik fixed carbon (z obliczeń) Fixed carbon indices (from calculations)","reference":"PN-G-04516:1998","norm_bases":["PN-G-04516:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Wskaźnik fixed carbon (z obliczeń) Fixed carbon indices (from calculations) PN-G-04516:1998 Paliwa stale: wegiel kamienny Solid fuels: hard coal Wskaznik fixed carbon (z obliczen) Fixed carbon indices (from calculations) PN-G-04516:1998","categories":["petro"],"row_index":478,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Fixed carbon indices (from calculations) PN-G-04516:1998","search_zh":"固体燃料：烟煤 PN-G-04516:1998","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ef9af9f73f38250c7b","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci pierwszego stopnia (wilgoć przemijająca) Zakres: (0,50 – 23,50) % Metoda wagowa First degree moisture content (transient moisture) Range: (0,50 – 23,50) % Weight method","methodology_en":"First degree moisture content (transient moisture) Range: (0,50 – 23,50) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci pierwszego stopnia (wilgoć przemijająca) Zakres: (0,50 – 23,50) % Metoda wagowa First degree moisture content (transient moisture) Range: (0,50 – 23,50) % Weight method","reference":"PN-ISO 589:2006 Metoda A2 PN-ISO 589:2006 A2 method","norm_bases":["PN-ISO 589:2006 Metoda A2 PN-ISO 589:2006 A2 method"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Zawartość wilgoci pierwszego stopnia (wilgoć przemijająca) Zakres: (0,50 – 23,50) % Metoda wagowa First degree moisture content (transient moisture) Range: (0,50 – 23,50) % Weight method PN-ISO 589:2006 Metoda A2 PN-ISO 589:2006 A2 method Paliwa stale: wegiel kamienny Solid fuels: hard coal Zawartosc wilgoci pierwszego stopnia (wilgoc przemijajaca) Zakres: (0,50 – 23,50) % Metoda wagowa First degree moisture content (transient moisture) Range: (0,50 – 23,50) % Weight method PN-ISO 589:2006 Metoda A2 PN-ISO 589:2006 A2 method","categories":["petro"],"row_index":479,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal First degree moisture content (transient moisture) Range: (0,50 – 23,50) % Weight method PN-ISO 589:2006 Metoda A2 PN-ISO 589:2006 A2 method","search_zh":"固体燃料：烟煤 PN-ISO 589:2006 Metoda A2 PN-ISO 589:2006 A2 method","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ef9af9f73f38250c7c","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci drugiego stopnia (wilgoć pozostała w próbce) Zakres: (0,20 – 17,00) % Metoda wagowa Second degree moisture content (moisture remaining in the sample) Range: (0,20 – 17,00) % Weight method","methodology_en":"Second degree moisture content (moisture remaining in the sample) Range: (0,20 – 17,00) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci drugiego stopnia (wilgoć pozostała w próbce) Zakres: (0,20 – 17,00) % Metoda wagowa Second degree moisture content (moisture remaining in the sample) Range: (0,20 – 17,00) % Weight method","reference":"PN-ISO 589:2006 Metoda A2 PN-ISO 589:2006 A2 method","norm_bases":["PN-ISO 589:2006 Metoda A2 PN-ISO 589:2006 A2 method"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Zawartość wilgoci drugiego stopnia (wilgoć pozostała w próbce) Zakres: (0,20 – 17,00) % Metoda wagowa Second degree moisture content (moisture remaining in the sample) Range: (0,20 – 17,00) % Weight method PN-ISO 589:2006 Metoda A2 PN-ISO 589:2006 A2 method Paliwa stale: wegiel kamienny Solid fuels: hard coal Zawartosc wilgoci drugiego stopnia (wilgoc pozostala w probce) Zakres: (0,20 – 17,00) % Metoda wagowa Second degree moisture content (moisture remaining in the sample) Range: (0,20 – 17,00) % Weight method PN-ISO 589:2006 Metoda A2 PN-ISO 589:2006 A2 method","categories":["petro"],"row_index":480,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Second degree moisture content (moisture remaining in the sample) Range: (0,20 – 17,00) % Weight method PN-ISO 589:2006 Metoda A2 PN-ISO 589:2006 A2 method","search_zh":"固体燃料：烟煤 PN-ISO 589:2006 Metoda A2 PN-ISO 589:2006 A2 method","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ef9af9f73f38250c7d","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci drugiego stopnia (wilgoć pozostała w próbce) Zakres: (1,10 – 9,70) % Metoda wagowa Second degree moisture content (moisture remaining in the sample) Range: (1,10 – 9,70) % Weight method","methodology_en":"Second degree moisture content (moisture remaining in the sample) Range: (1,10 – 9,70) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci drugiego stopnia (wilgoć pozostała w próbce) Zakres: (1,10 – 9,70) % Metoda wagowa Second degree moisture content (moisture remaining in the sample) Range: (1,10 – 9,70) % Weight method","reference":"PN-ISO 589:2006 A1 metoda PN-ISO 589:2006 A1 method","norm_bases":["PN-ISO 589:2006 A1 metoda PN-ISO 589:2006 A1 method"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Zawartość wilgoci drugiego stopnia (wilgoć pozostała w próbce) Zakres: (1,10 – 9,70) % Metoda wagowa Second degree moisture content (moisture remaining in the sample) Range: (1,10 – 9,70) % Weight method PN-ISO 589:2006 A1 metoda PN-ISO 589:2006 A1 method Paliwa stale: wegiel kamienny Solid fuels: hard coal Zawartosc wilgoci drugiego stopnia (wilgoc pozostala w probce) Zakres: (1,10 – 9,70) % Metoda wagowa Second degree moisture content (moisture remaining in the sample) Range: (1,10 – 9,70) % Weight method PN-ISO 589:2006 A1 metoda PN-ISO 589:2006 A1 method","categories":["petro"],"row_index":481,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Second degree moisture content (moisture remaining in the sample) Range: (1,10 – 9,70) % Weight method PN-ISO 589:2006 A1 metoda PN-ISO 589:2006 A1 method","search_zh":"固体燃料：烟煤 PN-ISO 589:2006 A1 metoda PN-ISO 589:2006 A1 method","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ef9af9f73f38250c7e","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Analiza ziarnowa Klasa (0,2 – 200,0) mm Zakres: (0,0 – 100,0) % Metoda sitowa Size analysis by sieving Class (0,2 – 200,0) mm Range: (0,0 – 100,0) % Sieve method","methodology_en":"Size analysis by sieving Class (0,2 – 200,0) mm Range: (0,0 – 100,0) % Sieve method Size analysis by sieving Class (0,2 – 200,0) mm Range: (0,0 – 100,0) % Sieve method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Analiza ziarnowa Klasa (0,2 – 200,0) mm Zakres: (0,0 – 100,0) % Metoda sitowa Size analysis by sieving Class (0,2 – 200,0) mm Range: (0,0 – 100,0) % Sieve method","reference":"PN-ISO 1953:1999","norm_bases":["PN-ISO 1953:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Analiza ziarnowa Klasa (0,2 – 200,0) mm Zakres: (0,0 – 100,0) % Metoda sitowa Size analysis by sieving Class (0,2 – 200,0) mm Range: (0,0 – 100,0) % Sieve method PN-ISO 1953:1999 Paliwa stale: wegiel kamienny Solid fuels: hard coal Analiza ziarnowa Klasa (0,2 – 200,0) mm Zakres: (0,0 – 100,0) % Metoda sitowa Size analysis by sieving Class (0,2 – 200,0) mm Range: (0,0 – 100,0) % Sieve method PN-ISO 1953:1999","categories":["petro"],"row_index":482,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Size analysis by sieving Class (0,2 – 200,0) mm Range: (0,0 – 100,0) % Sieve method Size analysis by sieving Class (0,2 – 200,0) mm Range: (0,0 – 100,0) % Sieve method PN-ISO 1953:1999","search_zh":"固体燃料：烟煤 PN-ISO 1953:1999","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ef9af9f73f38250c7f","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Wskaźnik samozapalności Sza’ (1 – 62) °C/min Sza (10 – 172) °C/min Metoda Olpińskiego Autioinflammability index Range: Sza’ (1 – 62) °C/min Sza (10 – 172) °C/min Olpiński method","methodology_en":"Autioinflammability index Range: Sza’ (1 – 62) °C/min Sza (10 – 172) °C/min Olpiński method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik samozapalności Sza’ (1 – 62) °C/min Sza (10 – 172) °C/min Metoda Olpińskiego Autioinflammability index Range: Sza’ (1 – 62) °C/min Sza (10 – 172) °C/min Olpiński method","reference":"PN-G-04558:1993","norm_bases":["PN-G-04558:1993"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Wskaźnik samozapalności Sza’ (1 – 62) °C/min Sza (10 – 172) °C/min Metoda Olpińskiego Autioinflammability index Range: Sza’ (1 – 62) °C/min Sza (10 – 172) °C/min Olpiński method PN-G-04558:1993 Paliwa stale: wegiel kamienny Solid fuels: hard coal Wskaznik samozapalnosci Sza’ (1 – 62) °C/min Sza (10 – 172) °C/min Metoda Olpinskiego Autioinflammability index Range: Sza’ (1 – 62) °C/min Sza (10 – 172) °C/min Olpinski method PN-G-04558:1993","categories":["petro"],"row_index":483,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Autioinflammability index Range: Sza’ (1 – 62) °C/min Sza (10 – 172) °C/min Olpiński method PN-G-04558:1993","search_zh":"固体燃料：烟煤 PN-G-04558:1993","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ef9af9f73f38250c80","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Wskaźnik podatności transportowej metodą GIG Zakres: (68 – 10 844) Pa Metoda tensometryczna Transportability index using by the GIG method Range: (68 – 10 844) Pa Tensiometric method","methodology_en":"Transportability index using by the GIG method Range: (68 – 10 844) Pa Tensiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik podatności transportowej metodą GIG Zakres: (68 – 10 844) Pa Metoda tensometryczna Transportability index using by the GIG method Range: (68 – 10 844) Pa Tensiometric method","reference":"PN-82/G-04544","norm_bases":["PN-82/G-04544"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Wskaźnik podatności transportowej metodą GIG Zakres: (68 – 10 844) Pa Metoda tensometryczna Transportability index using by the GIG method Range: (68 – 10 844) Pa Tensiometric method PN-82/G-04544 Paliwa stale: wegiel kamienny Solid fuels: hard coal Wskaznik podatnosci transportowej metoda GIG Zakres: (68 – 10 844) Pa Metoda tensometryczna Transportability index using by the GIG method Range: (68 – 10 844) Pa Tensiometric method PN-82/G-04544","categories":["petro"],"row_index":484,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Transportability index using by the GIG method Range: (68 – 10 844) Pa Tensiometric method PN-82/G-04544","search_zh":"固体燃料：烟煤 PN-82/G-04544","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ef9af9f73f38250c81","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal","test_object_en":"Solid fuels: hard coal, brown coal, coke from hard coal","methodology":"Zawartość wilgoci przemijającej Zakres: (0,50 – 45,00) % Metoda wagowa Transient moisture Range: (0,50 – 45,00) % Weight method","methodology_en":"Transient moisture Range: (0,50 – 45,00) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci przemijającej Zakres: (0,50 – 45,00) % Metoda wagowa Transient moisture Range: (0,50 – 45,00) % Weight method","reference":"PN-80/G-04511","norm_bases":["PN-80/G-04511"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartość wilgoci przemijającej Zakres: (0,50 – 45,00) % Metoda wagowa Transient moisture Range: (0,50 – 45,00) % Weight method PN-80/G-04511 Paliwa stale: wegiel kamienny, wegiel brunatny, koks z wegla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartosc wilgoci przemijajacej Zakres: (0,50 – 45,00) % Metoda wagowa Transient moisture Range: (0,50 – 45,00) % Weight method PN-80/G-04511","categories":["petro"],"row_index":485,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal, brown coal, coke from hard coal Transient moisture Range: (0,50 – 45,00) % Weight method PN-80/G-04511","search_zh":"固体燃料：烟煤、褐煤、烟煤焦炭 PN-80/G-04511","test_object_zh":"固体燃料：烟煤、褐煤、烟煤焦炭"},{"_id":"6a5a55ef9af9f73f38250c82","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal","test_object_en":"Solid fuels: hard coal, brown coal, coke from hard coal","methodology":"Zawartość wilgoci analitycznej Zakres: (0,20 – 17,20) % Metoda termograwimetryczna (TGA) Analytical moisture content Range: (0,20 - 17,20) % Thermogravimetric method (TGA)","methodology_en":"Analytical moisture content Range: (0,20 - 17,20) % Thermogravimetric method (TGA)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci analitycznej Zakres: (0,20 – 17,20) % Metoda termograwimetryczna (TGA) Analytical moisture content Range: (0,20 - 17,20) % Thermogravimetric method (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartość wilgoci analitycznej Zakres: (0,20 – 17,20) % Metoda termograwimetryczna (TGA) Analytical moisture content Range: (0,20 - 17,20) % Thermogravimetric method (TGA) PN-G-04560:1998 Paliwa stale: wegiel kamienny, wegiel brunatny, koks z wegla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartosc wilgoci analitycznej Zakres: (0,20 – 17,20) % Metoda termograwimetryczna (TGA) Analytical moisture content Range: (0,20 - 17,20) % Thermogravimetric method (TGA) PN-G-04560:1998","categories":["petro"],"row_index":486,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal, brown coal, coke from hard coal Analytical moisture content Range: (0,20 - 17,20) % Thermogravimetric method (TGA) PN-G-04560:1998","search_zh":"固体燃料：烟煤、褐煤、烟煤焦炭 PN-G-04560:1998","test_object_zh":"固体燃料：烟煤、褐煤、烟煤焦炭"},{"_id":"6a5a55ef9af9f73f38250c83","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal","test_object_en":"Solid fuels: hard coal, brown coal, coke from hard coal","methodology":"Zawartość wilgoci analitycznej Zakres: (0,05 – 17,00) % Metoda wagowa Analytical moisture content Range: (0,05 – 17,00) % Weight method","methodology_en":"Analytical moisture content Range: (0,05 – 17,00) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci analitycznej Zakres: (0,05 – 17,00) % Metoda wagowa Analytical moisture content Range: (0,05 – 17,00) % Weight method","reference":"PN-80/G-04511","norm_bases":["PN-80/G-04511"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartość wilgoci analitycznej Zakres: (0,05 – 17,00) % Metoda wagowa Analytical moisture content Range: (0,05 – 17,00) % Weight method PN-80/G-04511 Paliwa stale: wegiel kamienny, wegiel brunatny, koks z wegla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartosc wilgoci analitycznej Zakres: (0,05 – 17,00) % Metoda wagowa Analytical moisture content Range: (0,05 – 17,00) % Weight method PN-80/G-04511","categories":["petro"],"row_index":487,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal, brown coal, coke from hard coal Analytical moisture content Range: (0,05 – 17,00) % Weight method PN-80/G-04511","search_zh":"固体燃料：烟煤、褐煤、烟煤焦炭 PN-80/G-04511","test_object_zh":"固体燃料：烟煤、褐煤、烟煤焦炭"},{"_id":"6a5a55ef9af9f73f38250c84","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal","test_object_en":"Solid fuels: hard coal, brown coal, coke from hard coal","methodology":"Zawartość wilgoci całkowitej Zakres: (0,10 – 22,10) % Metoda wagowa Total moisture content Range: (0,10 – 22,10) % Weight method","methodology_en":"Total moisture content Range: (0,10 – 22,10) % Gravimetric method Total moisture content Range: (0,10 – 22,10) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej Zakres: (0,10 – 22,10) % Metoda wagowa Total moisture content Range: (0,10 – 22,10) % Weight method","reference":"PN-80/G-04511 pkt 2.3.4","norm_bases":["PN-80/G-04511 pkt 2.3.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartość wilgoci całkowitej Zakres: (0,10 – 22,10) % Metoda wagowa Total moisture content Range: (0,10 – 22,10) % Weight method PN-80/G-04511 pkt 2.3.4 Paliwa stale: wegiel kamienny, wegiel brunatny, koks z wegla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartosc wilgoci calkowitej Zakres: (0,10 – 22,10) % Metoda wagowa Total moisture content Range: (0,10 – 22,10) % Weight method PN-80/G-04511 pkt 2.3.4","categories":["petro"],"row_index":488,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal, brown coal, coke from hard coal Total moisture content Range: (0,10 – 22,10) % Gravimetric method Total moisture content Range: (0,10 – 22,10) % Weight method PN-80/G-04511 pkt 2.3.4","search_zh":"固体燃料：烟煤、褐煤、烟煤焦炭 PN-80/G-04511 pkt 2.3.4","test_object_zh":"固体燃料：烟煤、褐煤、烟煤焦炭"},{"_id":"6a5a55ef9af9f73f38250c85","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal","test_object_en":"Solid fuels: hard coal, brown coal, coke from hard coal","methodology":"Zawartość wilgoci całkowitej (z obliczeń) Total moisture content (from calculations)","methodology_en":"Total moisture content (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej (z obliczeń) Total moisture content (from calculations)","reference":"SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. PN-ISO 589:2006 SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. PN-ISO 589:2006 SW/ZLGIG/PB-16, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartość wilgoci całkowitej (z obliczeń) Total moisture content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. PN-ISO 589:2006 SW/ZLGIG/PB-16, 2nd edition of 18 August 2025 Paliwa stale: wegiel kamienny, wegiel brunatny, koks z wegla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartosc wilgoci calkowitej (z obliczen) Total moisture content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. PN-ISO 589:2006 SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","categories":["petro"],"row_index":489,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal, brown coal, coke from hard coal Total moisture content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. PN-ISO 589:2006 SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","search_zh":"固体燃料：烟煤、褐煤、烟煤焦炭 全水分含量（由计算得出） Total moisture content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. PN-ISO 589:2006 SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","test_object_zh":"固体燃料：烟煤、褐煤、烟煤焦炭","methodology_zh":"全水分含量（由计算得出） Total moisture content (from calculations)"},{"_id":"6a5a55ef9af9f73f38250c86","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal","test_object_en":"Solid fuels: hard coal, brown coal, coke from hard coal","methodology":"Zawartość popiołu Zakres: (1,10 - 95,85) % Metoda termograwimetryczna (TGA) Ash content Range: (1,10 – 95,85) % Thermogravimetric method (TGA)","methodology_en":"Ash content Range: (1,10 – 95,85) % Thermogravimetric method (TGA)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość popiołu Zakres: (1,10 - 95,85) % Metoda termograwimetryczna (TGA) Ash content Range: (1,10 – 95,85) % Thermogravimetric method (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartość popiołu Zakres: (1,10 - 95,85) % Metoda termograwimetryczna (TGA) Ash content Range: (1,10 – 95,85) % Thermogravimetric method (TGA) PN-G-04560:1998 Paliwa stale: wegiel kamienny, wegiel brunatny, koks z wegla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartosc popiolu Zakres: (1,10 - 95,85) % Metoda termograwimetryczna (TGA) Ash content Range: (1,10 – 95,85) % Thermogravimetric method (TGA) PN-G-04560:1998","categories":["petro"],"row_index":490,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal, brown coal, coke from hard coal Ash content Range: (1,10 – 95,85) % Thermogravimetric method (TGA) PN-G-04560:1998","search_zh":"固体燃料：烟煤、褐煤、烟煤焦炭 PN-G-04560:1998","test_object_zh":"固体燃料：烟煤、褐煤、烟煤焦炭"},{"_id":"6a5a55ef9af9f73f38250c87","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal","test_object_en":"Solid fuels: hard coal, brown coal, coke from hard coal","methodology":"Zawartość popiołu Zakres: (1,05 – 96,30) % Metoda wagowa Ash content Range: (1,05 – 96,30) % Weight method","methodology_en":"Ash content Range: (1,05 – 96,30) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość popiołu Zakres: (1,05 – 96,30) % Metoda wagowa Ash content Range: (1,05 – 96,30) % Weight method","reference":"PN-ISO 1171:2002","norm_bases":["PN-ISO 1171:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartość popiołu Zakres: (1,05 – 96,30) % Metoda wagowa Ash content Range: (1,05 – 96,30) % Weight method PN-ISO 1171:2002 Paliwa stale: wegiel kamienny, wegiel brunatny, koks z wegla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartosc popiolu Zakres: (1,05 – 96,30) % Metoda wagowa Ash content Range: (1,05 – 96,30) % Weight method PN-ISO 1171:2002","categories":["petro"],"row_index":491,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal, brown coal, coke from hard coal Ash content Range: (1,05 – 96,30) % Weight method PN-ISO 1171:2002","search_zh":"固体燃料：烟煤、褐煤、烟煤焦炭 PN-ISO 1171:2002","test_object_zh":"固体燃料：烟煤、褐煤、烟煤焦炭"},{"_id":"6a5a55ef9af9f73f38250c88","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal","test_object_en":"Solid fuels: hard coal, brown coal, coke from hard coal","methodology":"Zawartość części lotnych Zakres: (0,40 – 48,10) % Metoda wagowa Volatile matter content Range: (0,40 – 48,10) % Weight method","methodology_en":"Volatile matter content Range: (0,40 – 48,10) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość części lotnych Zakres: (0,40 – 48,10) % Metoda wagowa Volatile matter content Range: (0,40 – 48,10) % Weight method","reference":"PN-G-04516:1998","norm_bases":["PN-G-04516:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartość części lotnych Zakres: (0,40 – 48,10) % Metoda wagowa Volatile matter content Range: (0,40 – 48,10) % Weight method PN-G-04516:1998 Paliwa stale: wegiel kamienny, wegiel brunatny, koks z wegla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartosc czesci lotnych Zakres: (0,40 – 48,10) % Metoda wagowa Volatile matter content Range: (0,40 – 48,10) % Weight method PN-G-04516:1998","categories":["petro"],"row_index":492,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal, brown coal, coke from hard coal Volatile matter content Range: (0,40 – 48,10) % Weight method PN-G-04516:1998","search_zh":"固体燃料：烟煤、褐煤、烟煤焦炭 PN-G-04516:1998","test_object_zh":"固体燃料：烟煤、褐煤、烟煤焦炭"},{"_id":"6a5a55ef9af9f73f38250c89","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal","test_object_en":"Solid fuels: hard coal, brown coal, coke from hard coal","methodology":"Zawartość części lotnych Zakres: (0,40 – 48,90) % Metoda wagowa Volatile matter content Range: (0,40 – 48,90) % Weight method","methodology_en":"Volatile matter content Range: (0,40 – 48,90) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość części lotnych Zakres: (0,40 – 48,90) % Metoda wagowa Volatile matter content Range: (0,40 – 48,90) % Weight method","reference":"PN-ISO 562:2000","norm_bases":["PN-ISO 562:2000"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartość części lotnych Zakres: (0,40 – 48,90) % Metoda wagowa Volatile matter content Range: (0,40 – 48,90) % Weight method PN-ISO 562:2000 Paliwa stale: wegiel kamienny, wegiel brunatny, koks z wegla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartosc czesci lotnych Zakres: (0,40 – 48,90) % Metoda wagowa Volatile matter content Range: (0,40 – 48,90) % Weight method PN-ISO 562:2000","categories":["petro"],"row_index":493,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal, brown coal, coke from hard coal Volatile matter content Range: (0,40 – 48,90) % Weight method PN-ISO 562:2000","search_zh":"固体燃料：烟煤、褐煤、烟煤焦炭 PN-ISO 562:2000","test_object_zh":"固体燃料：烟煤、褐煤、烟煤焦炭"},{"_id":"6a5a55ef9af9f73f38250c8a","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal","test_object_en":"Solid fuels: hard coal, brown coal, coke from hard coal","methodology":"Ciepło spalania Zakres: (1460 – 35900) kJ/kg Metoda kalorymetryczna Gross calorific value Range: (1460 – 35900) kJ/kg Calorimetric method","methodology_en":"Gross calorific value Range: (1460 – 35900) kJ/kg Calorimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciepło spalania Zakres: (1460 – 35900) kJ/kg Metoda kalorymetryczna Gross calorific value Range: (1460 – 35900) kJ/kg Calorimetric method","reference":"PN-81/G-04513 PN-ISO 1928:2020-05","norm_bases":["PN-81/G-04513 PN-ISO 1928:2020-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Ciepło spalania Zakres: (1460 – 35900) kJ/kg Metoda kalorymetryczna Gross calorific value Range: (1460 – 35900) kJ/kg Calorimetric method PN-81/G-04513 PN-ISO 1928:2020-05 Paliwa stale: wegiel kamienny, wegiel brunatny, koks z wegla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Cieplo spalania Zakres: (1460 – 35900) kJ/kg Metoda kalorymetryczna Gross calorific value Range: (1460 – 35900) kJ/kg Calorimetric method PN-81/G-04513 PN-ISO 1928:2020-05","categories":["petro"],"row_index":494,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal, brown coal, coke from hard coal Gross calorific value Range: (1460 – 35900) kJ/kg Calorimetric method PN-81/G-04513 PN-ISO 1928:2020-05","search_zh":"固体燃料：烟煤、褐煤、烟煤焦炭 PN-81/G-04513 PN-ISO 1928:2020-05","test_object_zh":"固体燃料：烟煤、褐煤、烟煤焦炭"},{"_id":"6a5a55ef9af9f73f38250c8b","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal","test_object_en":"Solid fuels: hard coal, brown coal, coke from hard coal","methodology":"Wartość opałowa (z obliczeń) Net calorific value (from calculations)","methodology_en":"Net calorific value (calculated) Net calorific value (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wartość opałowa (z obliczeń) Net calorific value (from calculations)","reference":"PN-81/G-04513 PN-ISO 1928:2020-05","norm_bases":["PN-81/G-04513 PN-ISO 1928:2020-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Wartość opałowa (z obliczeń) Net calorific value (from calculations) PN-81/G-04513 PN-ISO 1928:2020-05 Paliwa stale: wegiel kamienny, wegiel brunatny, koks z wegla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Wartosc opalowa (z obliczen) Net calorific value (from calculations) PN-81/G-04513 PN-ISO 1928:2020-05","categories":["petro"],"row_index":495,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal, brown coal, coke from hard coal Net calorific value (calculated) Net calorific value (from calculations) PN-81/G-04513 PN-ISO 1928:2020-05","search_zh":"固体燃料：烟煤、褐煤、烟煤焦炭 低位发热量（由计算得出） Net calorific value (from calculations) PN-81/G-04513 PN-ISO 1928:2020-05","test_object_zh":"固体燃料：烟煤、褐煤、烟煤焦炭","methodology_zh":"低位发热量（由计算得出） Net calorific value (from calculations)"},{"_id":"6a5a55ef9af9f73f38250c8c","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal","test_object_en":"Solid fuels: hard coal, brown coal, coke from hard coal","methodology":"Zawartość siarki całkowitej Zakres: (0,20 – 7,00) % Metoda wysokotemperaturowego spalania z detekcją IR Total sulphur content Range: (0,20 – 7,00) % High-temperature combustion method with IR detection","methodology_en":"Total sulphur content Range: (0,20 – 7,00) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej Zakres: (0,20 – 7,00) % Metoda wysokotemperaturowego spalania z detekcją IR Total sulphur content Range: (0,20 – 7,00) % High-temperature combustion method with IR detection","reference":"PN-G-04584:2001","norm_bases":["PN-G-04584:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartość siarki całkowitej Zakres: (0,20 – 7,00) % Metoda wysokotemperaturowego spalania z detekcją IR Total sulphur content Range: (0,20 – 7,00) % High-temperature combustion method with IR detection PN-G-04584:2001 Paliwa stale: wegiel kamienny, wegiel brunatny, koks z wegla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartosc siarki calkowitej Zakres: (0,20 – 7,00) % Metoda wysokotemperaturowego spalania z detekcja IR Total sulphur content Range: (0,20 – 7,00) % High-temperature combustion method with IR detection PN-G-04584:2001","categories":["petro"],"row_index":496,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal, brown coal, coke from hard coal Total sulphur content Range: (0,20 – 7,00) % High-temperature combustion method with IR detection PN-G-04584:2001","search_zh":"固体燃料：烟煤、褐煤、烟煤焦炭 PN-G-04584:2001","test_object_zh":"固体燃料：烟煤、褐煤、烟煤焦炭"},{"_id":"6a5a55ef9af9f73f38250c8d","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal","test_object_en":"Solid fuels: hard coal, brown coal, coke from hard coal","methodology":"Zawartość siarki całkowitej Zakres: (0,20 – 7,00) % Metoda wagowa Total sulphur content Range: (0,20 – 7,00) % Weight method","methodology_en":"Total sulphur content Range: (0,20 – 7,00) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej Zakres: (0,20 – 7,00) % Metoda wagowa Total sulphur content Range: (0,20 – 7,00) % Weight method","reference":"PN-ISO 334:1997","norm_bases":["PN-ISO 334:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartość siarki całkowitej Zakres: (0,20 – 7,00) % Metoda wagowa Total sulphur content Range: (0,20 – 7,00) % Weight method PN-ISO 334:1997 Paliwa stale: wegiel kamienny, wegiel brunatny, koks z wegla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartosc siarki calkowitej Zakres: (0,20 – 7,00) % Metoda wagowa Total sulphur content Range: (0,20 – 7,00) % Weight method PN-ISO 334:1997","categories":["petro"],"row_index":497,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal, brown coal, coke from hard coal Total sulphur content Range: (0,20 – 7,00) % Weight method PN-ISO 334:1997","search_zh":"固体燃料：烟煤、褐煤、烟煤焦炭 PN-ISO 334:1997","test_object_zh":"固体燃料：烟煤、褐煤、烟煤焦炭"},{"_id":"6a5a55ef9af9f73f38250c8e","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal","test_object_en":"Solid fuels: hard coal, brown coal, coke from hard coal","methodology":"Zawartość siarki w popiele i siarki popiołowej Zakres: (0,06 – 0,60) % Metoda wysokotemperaturowego spalania z detekcją IR Sulphur content in ash and ash sulphur content Range: (0,06 – 0,60) % High-temperature combustion method with IR detection","methodology_en":"Sulphur content in ash and ash sulphur content Range: (0,06 – 0,60) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość siarki w popiele i siarki popiołowej Zakres: (0,06 – 0,60) % Metoda wysokotemperaturowego spalania z detekcją IR Sulphur content in ash and ash sulphur content Range: (0,06 – 0,60) % High-temperature combustion method with IR detection","reference":"PN-G-04584:2001","norm_bases":["PN-G-04584:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartość siarki w popiele i siarki popiołowej Zakres: (0,06 – 0,60) % Metoda wysokotemperaturowego spalania z detekcją IR Sulphur content in ash and ash sulphur content Range: (0,06 – 0,60) % High-temperature combustion method with IR detection PN-G-04584:2001 Paliwa stale: wegiel kamienny, wegiel brunatny, koks z wegla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartosc siarki w popiele i siarki popiolowej Zakres: (0,06 – 0,60) % Metoda wysokotemperaturowego spalania z detekcja IR Sulphur content in ash and ash sulphur content Range: (0,06 – 0,60) % High-temperature combustion method with IR detection PN-G-04584:2001","categories":["petro"],"row_index":498,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal, brown coal, coke from hard coal Sulphur content in ash and ash sulphur content Range: (0,06 – 0,60) % High-temperature combustion method with IR detection PN-G-04584:2001","search_zh":"固体燃料：烟煤、褐煤、烟煤焦炭 PN-G-04584:2001","test_object_zh":"固体燃料：烟煤、褐煤、烟煤焦炭"},{"_id":"6a5a55ef9af9f73f38250c8f","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal","test_object_en":"Solid fuels: hard coal, brown coal, coke from hard coal","methodology":"Zawartość siarki palnej (z obliczeń) Combustible sulphur content (from calculations)","methodology_en":"Combustible sulphur content (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość siarki palnej (z obliczeń) Combustible sulphur content (from calculations)","reference":"PN-G-04584:2001","norm_bases":["PN-G-04584:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartość siarki palnej (z obliczeń) Combustible sulphur content (from calculations) PN-G-04584:2001 Paliwa stale: wegiel kamienny, wegiel brunatny, koks z wegla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartosc siarki palnej (z obliczen) Combustible sulphur content (from calculations) PN-G-04584:2001","categories":["petro"],"row_index":499,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal, brown coal, coke from hard coal Combustible sulphur content (from calculations) PN-G-04584:2001","search_zh":"固体燃料：烟煤、褐煤、烟煤焦炭 PN-G-04584:2001","test_object_zh":"固体燃料：烟煤、褐煤、烟煤焦炭"},{"_id":"6a5a55ef9af9f73f38250c90","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal","test_object_en":"Solid fuels: hard coal, brown coal, coke from hard coal","methodology":"Zawartość siarki organicznej (z obliczeń) Organic sulphur content (from calculations)","methodology_en":"Organic sulphur content (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość siarki organicznej (z obliczeń) Organic sulphur content (from calculations)","reference":"SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartość siarki organicznej (z obliczeń) Organic sulphur content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025 Paliwa stale: wegiel kamienny, wegiel brunatny, koks z wegla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartosc siarki organicznej (z obliczen) Organic sulphur content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","categories":["petro"],"row_index":500,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal, brown coal, coke from hard coal Organic sulphur content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","search_zh":"固体燃料：烟煤、褐煤、烟煤焦炭 SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","test_object_zh":"固体燃料：烟煤、褐煤、烟煤焦炭"},{"_id":"6a5a55ef9af9f73f38250c91","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal","test_object_en":"Solid fuels: hard coal, brown coal, coke from hard coal","methodology":"Zawartość węgla Zakres: (1,00 – 100,00) % Metoda wysokotemperaturowego spalania z detekcją IR Carbon content Range: (1,00 – 100,00) % High-temperature combustion method with IR detection","methodology_en":"Carbon content Range: (1,00 – 100,00) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość węgla Zakres: (1,00 – 100,00) % Metoda wysokotemperaturowego spalania z detekcją IR Carbon content Range: (1,00 – 100,00) % High-temperature combustion method with IR detection","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartość węgla Zakres: (1,00 – 100,00) % Metoda wysokotemperaturowego spalania z detekcją IR Carbon content Range: (1,00 – 100,00) % High-temperature combustion method with IR detection PN-G-04571:1998 Paliwa stale: wegiel kamienny, wegiel brunatny, koks z wegla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartosc wegla Zakres: (1,00 – 100,00) % Metoda wysokotemperaturowego spalania z detekcja IR Carbon content Range: (1,00 – 100,00) % High-temperature combustion method with IR detection PN-G-04571:1998","categories":["petro"],"row_index":501,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal, brown coal, coke from hard coal Carbon content Range: (1,00 – 100,00) % High-temperature combustion method with IR detection PN-G-04571:1998","search_zh":"固体燃料：烟煤、褐煤、烟煤焦炭 PN-G-04571:1998","test_object_zh":"固体燃料：烟煤、褐煤、烟煤焦炭"},{"_id":"6a5a55ef9af9f73f38250c92","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal","test_object_en":"Solid fuels: hard coal, brown coal, coke from hard coal","methodology":"Zawartość azotu Zakres: (0,30 - 2,50) % Metoda wysokotemperaturowego spalania z detekcją TC Nitrogen content Range: (0,30 – 2,50) % High-temperature combustion method with TC detection","methodology_en":"Nitrogen content Range: (0,30 – 2,50) % High-temperature combustion method with TC detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość azotu Zakres: (0,30 - 2,50) % Metoda wysokotemperaturowego spalania z detekcją TC Nitrogen content Range: (0,30 – 2,50) % High-temperature combustion method with TC detection","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartość azotu Zakres: (0,30 - 2,50) % Metoda wysokotemperaturowego spalania z detekcją TC Nitrogen content Range: (0,30 – 2,50) % High-temperature combustion method with TC detection PN-G-04571:1998 Paliwa stale: wegiel kamienny, wegiel brunatny, koks z wegla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartosc azotu Zakres: (0,30 - 2,50) % Metoda wysokotemperaturowego spalania z detekcja TC Nitrogen content Range: (0,30 – 2,50) % High-temperature combustion method with TC detection PN-G-04571:1998","categories":["petro"],"row_index":502,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal, brown coal, coke from hard coal Nitrogen content Range: (0,30 – 2,50) % High-temperature combustion method with TC detection PN-G-04571:1998","search_zh":"固体燃料：烟煤、褐煤、烟煤焦炭 PN-G-04571:1998","test_object_zh":"固体燃料：烟煤、褐煤、烟煤焦炭"},{"_id":"6a5a55ef9af9f73f38250c93","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal","test_object_en":"Solid fuels: hard coal, brown coal, coke from hard coal","methodology":"Zawartość tlenu (z obliczeń) Oxygen content (from calculations)","methodology_en":"Oxygen content (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość tlenu (z obliczeń) Oxygen content (from calculations)","reference":"SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartość tlenu (z obliczeń) Oxygen content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025 Paliwa stale: wegiel kamienny, wegiel brunatny, koks z wegla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Zawartosc tlenu (z obliczen) Oxygen content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","categories":["petro"],"row_index":503,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal, brown coal, coke from hard coal Oxygen content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","search_zh":"固体燃料：烟煤、褐煤、烟煤焦炭 氧含量（由计算得出） Oxygen content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","test_object_zh":"固体燃料：烟煤、褐煤、烟煤焦炭","methodology_zh":"氧含量（由计算得出） Oxygen content (from calculations)"},{"_id":"6a5a55ef9af9f73f38250c94","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal","test_object_en":"Solid fuels: hard coal, brown coal, coke from hard coal","methodology":"Charakterystyczne temperatury topliwości popiołu Zakres: (860 – 1550) °C Metoda wysokotemperaturowej mikroskopii Characteristic temperatures of fusibility of ash Range: (860 – 1550) °C High-temperature microscopy method","methodology_en":"Characteristic temperatures of fusibility of ash Range: (860 – 1550) °C High-temperature microscopy method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Charakterystyczne temperatury topliwości popiołu Zakres: (860 – 1550) °C Metoda wysokotemperaturowej mikroskopii Characteristic temperatures of fusibility of ash Range: (860 – 1550) °C High-temperature microscopy method","reference":"PN-82/G-04535 PN-ISO 540:2001","norm_bases":["PN-82/G-04535 PN-ISO 540:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, węgiel brunatny, koks z węgla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Charakterystyczne temperatury topliwości popiołu Zakres: (860 – 1550) °C Metoda wysokotemperaturowej mikroskopii Characteristic temperatures of fusibility of ash Range: (860 – 1550) °C High-temperature microscopy method PN-82/G-04535 PN-ISO 540:2001 Paliwa stale: wegiel kamienny, wegiel brunatny, koks z wegla kamiennego Solid fuels: hard coal, brown coal, coke from hard coal Charakterystyczne temperatury topliwosci popiolu Zakres: (860 – 1550) °C Metoda wysokotemperaturowej mikroskopii Characteristic temperatures of fusibility of ash Range: (860 – 1550) °C High-temperature microscopy method PN-82/G-04535 PN-ISO 540:2001","categories":["petro"],"row_index":504,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal, brown coal, coke from hard coal Characteristic temperatures of fusibility of ash Range: (860 – 1550) °C High-temperature microscopy method PN-82/G-04535 PN-ISO 540:2001","search_zh":"固体燃料：烟煤、褐煤、烟煤焦炭 PN-82/G-04535 PN-ISO 540:2001","test_object_zh":"固体燃料：烟煤、褐煤、烟煤焦炭"},{"_id":"6a5a55ef9af9f73f38250c95","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: koks z węgla kamiennego Solid fuels: coke from hard coal","test_object_en":"Solid fuels: coke from hard coal","methodology":"Zawartość wilgoci całkowitej Zakres: (0,10 – 22,10) % Metoda wagowa Total moisture content Range: (0,10 – 22,10) % Weight method","methodology_en":"Total moisture content Range: (0,10 – 22,10) % Gravimetric method Total moisture content Range: (0,10 – 22,10) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej Zakres: (0,10 – 22,10) % Metoda wagowa Total moisture content Range: (0,10 – 22,10) % Weight method","reference":"PN-G-04611:2020-06","norm_bases":["PN-G-04611:2020-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: koks z węgla kamiennego Solid fuels: coke from hard coal Zawartość wilgoci całkowitej Zakres: (0,10 – 22,10) % Metoda wagowa Total moisture content Range: (0,10 – 22,10) % Weight method PN-G-04611:2020-06 Paliwa stale: koks z wegla kamiennego Solid fuels: coke from hard coal Zawartosc wilgoci calkowitej Zakres: (0,10 – 22,10) % Metoda wagowa Total moisture content Range: (0,10 – 22,10) % Weight method PN-G-04611:2020-06","categories":["petro"],"row_index":505,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: coke from hard coal Total moisture content Range: (0,10 – 22,10) % Gravimetric method Total moisture content Range: (0,10 – 22,10) % Weight method PN-G-04611:2020-06"},{"_id":"6a5a55ef9af9f73f38250c96","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: koks z węgla kamiennego Solid fuels: coke from hard coal","test_object_en":"Solid fuels: coke from hard coal","methodology":"Zawartość wodoru Zakres: (0,04 – 1,80) % Metoda wysokotemperaturowego spalania z detekcją IR Hydrogen content Range: (0,04 – 1,80) % High-temperature combustion method with IR detection","methodology_en":"Hydrogen content Range: (0,04 – 1,80) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wodoru Zakres: (0,04 – 1,80) % Metoda wysokotemperaturowego spalania z detekcją IR Hydrogen content Range: (0,04 – 1,80) % High-temperature combustion method with IR detection","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: koks z węgla kamiennego Solid fuels: coke from hard coal Zawartość wodoru Zakres: (0,04 – 1,80) % Metoda wysokotemperaturowego spalania z detekcją IR Hydrogen content Range: (0,04 – 1,80) % High-temperature combustion method with IR detection PN-G-04571:1998 Paliwa stale: koks z wegla kamiennego Solid fuels: coke from hard coal Zawartosc wodoru Zakres: (0,04 – 1,80) % Metoda wysokotemperaturowego spalania z detekcja IR Hydrogen content Range: (0,04 – 1,80) % High-temperature combustion method with IR detection PN-G-04571:1998","categories":["petro"],"row_index":506,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: coke from hard coal Hydrogen content Range: (0,04 – 1,80) % High-temperature combustion method with IR detection PN-G-04571:1998"},{"_id":"6a5a55ef9af9f73f38250c97","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wodoru Zakres: (1,30 - 6,40) % Metoda wysokotemperaturowego spalania z detekcją IR Hydrogen content Range: (1,30 - 6,40) % High-temperature combustion method with IR detection","methodology_en":"Hydrogen content Range: (1,30 - 6,40) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wodoru Zakres: (1,30 - 6,40) % Metoda wysokotemperaturowego spalania z detekcją IR Hydrogen content Range: (1,30 - 6,40) % High-temperature combustion method with IR detection","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Solid fuels: hard coal Zawartość wodoru Zakres: (1,30 - 6,40) % Metoda wysokotemperaturowego spalania z detekcją IR Hydrogen content Range: (1,30 - 6,40) % High-temperature combustion method with IR detection PN-G-04571:1998 Paliwa stale: wegiel kamienny Solid fuels: hard coal Zawartosc wodoru Zakres: (1,30 - 6,40) % Metoda wysokotemperaturowego spalania z detekcja IR Hydrogen content Range: (1,30 - 6,40) % High-temperature combustion method with IR detection PN-G-04571:1998","categories":["petro"],"row_index":507,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Hydrogen content Range: (1,30 - 6,40) % High-temperature combustion method with IR detection PN-G-04571:1998","search_zh":"固体燃料：烟煤 PN-G-04571:1998","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55ef9af9f73f38250c98","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel brunatny Solid fuels: brown coal","test_object_en":"Solid fuels: brown coal","methodology":"Zawartość wodoru Zakres: (3,60 – 6,20) % Metoda wysokotemperaturowego spalania z detekcją IR Hydrogen content Range: (3,60 – 6,20) % High-temperature combustion method with IR detection","methodology_en":"Hydrogen content Range: (3,60 – 6,20) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wodoru Zakres: (3,60 – 6,20) % Metoda wysokotemperaturowego spalania z detekcją IR Hydrogen content Range: (3,60 – 6,20) % High-temperature combustion method with IR detection","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel brunatny Solid fuels: brown coal Zawartość wodoru Zakres: (3,60 – 6,20) % Metoda wysokotemperaturowego spalania z detekcją IR Hydrogen content Range: (3,60 – 6,20) % High-temperature combustion method with IR detection PN-G-04571:1998 Paliwa stale: wegiel brunatny Solid fuels: brown coal Zawartosc wodoru Zakres: (3,60 – 6,20) % Metoda wysokotemperaturowego spalania z detekcja IR Hydrogen content Range: (3,60 – 6,20) % High-temperature combustion method with IR detection PN-G-04571:1998","categories":["petro"],"row_index":508,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: brown coal Hydrogen content Range: (3,60 – 6,20) % High-temperature combustion method with IR detection PN-G-04571:1998"},{"_id":"6a5a55ef9af9f73f38250c99","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: mieszanki biopaliwa stałego z paliwem stałym, mieszanki stałego paliwa wtórnego z paliwem stałym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel","test_object_en":"Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel","methodology":"Zawartość wilgoci przemijającej Zakres (1,30 – 19,70) % Metoda wagowa Transient moisture Range: (1,30 – 19,70) % Weight method","methodology_en":"Transient moisture Range: (1,30 – 19,70) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci przemijającej Zakres (1,30 – 19,70) % Metoda wagowa Transient moisture Range: (1,30 – 19,70) % Weight method","reference":"SW/ZLGIG/PB-03 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-03, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-03 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-03, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: mieszanki biopaliwa stałego z paliwem stałym, mieszanki stałego paliwa wtórnego z paliwem stałym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Zawartość wilgoci przemijającej Zakres (1,30 – 19,70) % Metoda wagowa Transient moisture Range: (1,30 – 19,70) % Weight method SW/ZLGIG/PB-03 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-03, 2nd edition of 18 August 2025 Paliwa stale: mieszanki biopaliwa stalego z paliwem stalym, mieszanki stalego paliwa wtornego z paliwem stalym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Zawartosc wilgoci przemijajacej Zakres (1,30 – 19,70) % Metoda wagowa Transient moisture Range: (1,30 – 19,70) % Weight method SW/ZLGIG/PB-03 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-03, 2nd edition of 18 August 2025","categories":["petro"],"row_index":509,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Transient moisture Range: (1,30 – 19,70) % Weight method SW/ZLGIG/PB-03 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-03, 2nd edition of 18 August 2025","search_zh":"固体燃料：固体生物燃料与固体燃料的混合物、固体再生燃料与固体燃料的混合物 Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel SW/ZLGIG/PB-03 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-03, 2nd edition of 18 August 2025","test_object_zh":"固体燃料：固体生物燃料与固体燃料的混合物、固体再生燃料与固体燃料的混合物 Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel"},{"_id":"6a5a55ef9af9f73f38250c9a","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: mieszanki biopaliwa stałego z paliwem stałym, mieszanki stałego paliwa wtórnego z paliwem stałym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel","test_object_en":"Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel","methodology":"Zawartość wilgoci w próbce analitycznej Zakres: (0,40 – 16,30) % Metoda termograwimetryczna (TGA) Moisture content in analytical sample Range: (0,40 – 16,30) % Thermogravimetric method (TGA)","methodology_en":"Moisture content in analytical sample Range: (0,40 – 16,30) % Thermogravimetric method (TGA)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej Zakres: (0,40 – 16,30) % Metoda termograwimetryczna (TGA) Moisture content in analytical sample Range: (0,40 – 16,30) % Thermogravimetric method (TGA)","reference":"SW/ZLGIG/PB-04 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-04, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-04 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-04, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: mieszanki biopaliwa stałego z paliwem stałym, mieszanki stałego paliwa wtórnego z paliwem stałym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Zawartość wilgoci w próbce analitycznej Zakres: (0,40 – 16,30) % Metoda termograwimetryczna (TGA) Moisture content in analytical sample Range: (0,40 – 16,30) % Thermogravimetric method (TGA) SW/ZLGIG/PB-04 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-04, 2nd edition of 18 August 2025 Paliwa stale: mieszanki biopaliwa stalego z paliwem stalym, mieszanki stalego paliwa wtornego z paliwem stalym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Zawartosc wilgoci w probce analitycznej Zakres: (0,40 – 16,30) % Metoda termograwimetryczna (TGA) Moisture content in analytical sample Range: (0,40 – 16,30) % Thermogravimetric method (TGA) SW/ZLGIG/PB-04 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-04, 2nd edition of 18 August 2025","categories":["petro"],"row_index":510,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Moisture content in analytical sample Range: (0,40 – 16,30) % Thermogravimetric method (TGA) SW/ZLGIG/PB-04 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-04, 2nd edition of 18 August 2025","search_zh":"固体燃料：固体生物燃料与固体燃料的混合物、固体再生燃料与固体燃料的混合物 Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel SW/ZLGIG/PB-04 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-04, 2nd edition of 18 August 2025","test_object_zh":"固体燃料：固体生物燃料与固体燃料的混合物、固体再生燃料与固体燃料的混合物 Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel"},{"_id":"6a5a55ef9af9f73f38250c9b","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: mieszanki biopaliwa stałego z paliwem stałym, mieszanki stałego paliwa wtórnego z paliwem stałym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel","test_object_en":"Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel","methodology":"Zawartość wilgoci w próbce analitycznej Zakres: (0,35 – 16,60) % Metoda wagowa Moisture content in analytical sample Range: (0,35 – 16,60) % Weight method","methodology_en":"Moisture content in analytical sample Range: (0,35 – 16,60) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej Zakres: (0,35 – 16,60) % Metoda wagowa Moisture content in analytical sample Range: (0,35 – 16,60) % Weight method","reference":"SW/ZLGIG/PB-05 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-05, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-05 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-05, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: mieszanki biopaliwa stałego z paliwem stałym, mieszanki stałego paliwa wtórnego z paliwem stałym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Zawartość wilgoci w próbce analitycznej Zakres: (0,35 – 16,60) % Metoda wagowa Moisture content in analytical sample Range: (0,35 – 16,60) % Weight method SW/ZLGIG/PB-05 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-05, 2nd edition of 18 August 2025 Paliwa stale: mieszanki biopaliwa stalego z paliwem stalym, mieszanki stalego paliwa wtornego z paliwem stalym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Zawartosc wilgoci w probce analitycznej Zakres: (0,35 – 16,60) % Metoda wagowa Moisture content in analytical sample Range: (0,35 – 16,60) % Weight method SW/ZLGIG/PB-05 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-05, 2nd edition of 18 August 2025","categories":["petro"],"row_index":511,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Moisture content in analytical sample Range: (0,35 – 16,60) % Weight method SW/ZLGIG/PB-05 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-05, 2nd edition of 18 August 2025","search_zh":"固体燃料：固体生物燃料与固体燃料的混合物、固体再生燃料与固体燃料的混合物 Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel SW/ZLGIG/PB-05 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-05, 2nd edition of 18 August 2025","test_object_zh":"固体燃料：固体生物燃料与固体燃料的混合物、固体再生燃料与固体燃料的混合物 Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel"},{"_id":"6a5a55ef9af9f73f38250c9c","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: mieszanki biopaliwa stałego z paliwem stałym, mieszanki stałego paliwa wtórnego z paliwem stałym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel","test_object_en":"Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel","methodology":"Zawartość wilgoci całkowitej (z obliczeń) Total moisture content (from calculations)","methodology_en":"Total moisture content (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej (z obliczeń) Total moisture content (from calculations)","reference":"SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: mieszanki biopaliwa stałego z paliwem stałym, mieszanki stałego paliwa wtórnego z paliwem stałym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Zawartość wilgoci całkowitej (z obliczeń) Total moisture content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025 Paliwa stale: mieszanki biopaliwa stalego z paliwem stalym, mieszanki stalego paliwa wtornego z paliwem stalym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Zawartosc wilgoci calkowitej (z obliczen) Total moisture content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","categories":["petro"],"row_index":512,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Total moisture content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","search_zh":"固体燃料：固体生物燃料与固体燃料的混合物、固体再生燃料与固体燃料的混合物 Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel 全水分含量（由计算得出） Total moisture content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","test_object_zh":"固体燃料：固体生物燃料与固体燃料的混合物、固体再生燃料与固体燃料的混合物 Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel","methodology_zh":"全水分含量（由计算得出） Total moisture content (from calculations)"},{"_id":"6a5a55ef9af9f73f38250c9d","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: mieszanki biopaliwa stałego z paliwem stałym, mieszanki stałego paliwa wtórnego z paliwem stałym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel","test_object_en":"Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel","methodology":"Zawartość popiołu Zakres: (3,60 – 81,00) % Metoda termograwimetryczna (TGA) Ash content Range: (3,60 – 81,00) % Thermogravimetric method (TGA)","methodology_en":"Ash content Range: (3,60 – 81,00) % Thermogravimetric method (TGA)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość popiołu Zakres: (3,60 – 81,00) % Metoda termograwimetryczna (TGA) Ash content Range: (3,60 – 81,00) % Thermogravimetric method (TGA)","reference":"SW/ZLGIG/PB-07 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-07, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-07 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-07, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: mieszanki biopaliwa stałego z paliwem stałym, mieszanki stałego paliwa wtórnego z paliwem stałym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Zawartość popiołu Zakres: (3,60 – 81,00) % Metoda termograwimetryczna (TGA) Ash content Range: (3,60 – 81,00) % Thermogravimetric method (TGA) SW/ZLGIG/PB-07 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-07, 2nd edition of 18 August 2025 Paliwa stale: mieszanki biopaliwa stalego z paliwem stalym, mieszanki stalego paliwa wtornego z paliwem stalym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Zawartosc popiolu Zakres: (3,60 – 81,00) % Metoda termograwimetryczna (TGA) Ash content Range: (3,60 – 81,00) % Thermogravimetric method (TGA) SW/ZLGIG/PB-07 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-07, 2nd edition of 18 August 2025","categories":["petro"],"row_index":513,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Ash content Range: (3,60 – 81,00) % Thermogravimetric method (TGA) SW/ZLGIG/PB-07 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-07, 2nd edition of 18 August 2025","search_zh":"固体燃料：固体生物燃料与固体燃料的混合物、固体再生燃料与固体燃料的混合物 Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel SW/ZLGIG/PB-07 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-07, 2nd edition of 18 August 2025","test_object_zh":"固体燃料：固体生物燃料与固体燃料的混合物、固体再生燃料与固体燃料的混合物 Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel"},{"_id":"6a5a55ef9af9f73f38250c9e","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: mieszanki biopaliwa stałego z paliwem stałym, mieszanki stałego paliwa wtórnego z paliwem stałym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel","test_object_en":"Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel","methodology":"Zawartość popiołu Zakres: (3,60 – 81,00) % Metoda wagowa (powolnego spopielania) Ash content Range: (3,60 – 81,00) % Weight method (slow burning)","methodology_en":"Ash content Range: (3,60 – 81,00) % Weight method (slow burning)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość popiołu Zakres: (3,60 – 81,00) % Metoda wagowa (powolnego spopielania) Ash content Range: (3,60 – 81,00) % Weight method (slow burning)","reference":"SW/ZLGIG/PB-06 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-06, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-06 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-06, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: mieszanki biopaliwa stałego z paliwem stałym, mieszanki stałego paliwa wtórnego z paliwem stałym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Zawartość popiołu Zakres: (3,60 – 81,00) % Metoda wagowa (powolnego spopielania) Ash content Range: (3,60 – 81,00) % Weight method (slow burning) SW/ZLGIG/PB-06 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-06, 2nd edition of 18 August 2025 Paliwa stale: mieszanki biopaliwa stalego z paliwem stalym, mieszanki stalego paliwa wtornego z paliwem stalym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Zawartosc popiolu Zakres: (3,60 – 81,00) % Metoda wagowa (powolnego spopielania) Ash content Range: (3,60 – 81,00) % Weight method (slow burning) SW/ZLGIG/PB-06 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-06, 2nd edition of 18 August 2025","categories":["petro"],"row_index":514,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Ash content Range: (3,60 – 81,00) % Weight method (slow burning) SW/ZLGIG/PB-06 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-06, 2nd edition of 18 August 2025","search_zh":"固体燃料：固体生物燃料与固体燃料的混合物、固体再生燃料与固体燃料的混合物 Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel SW/ZLGIG/PB-06 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-06, 2nd edition of 18 August 2025","test_object_zh":"固体燃料：固体生物燃料与固体燃料的混合物、固体再生燃料与固体燃料的混合物 Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel"},{"_id":"6a5a55ef9af9f73f38250c9f","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: mieszanki biopaliwa stałego z paliwem stałym, mieszanki stałego paliwa wtórnego z paliwem stałym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel","test_object_en":"Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel","methodology":"Zawartość węgla Zakres: (34,00 – 85,50) % Metoda wysokotemperaturowego spalania z detekcją IR Carbon content Range: (34,00 – 85,50) % High-temperature combustion method with IR detection","methodology_en":"Carbon content Range: (34,00 – 85,50) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość węgla Zakres: (34,00 – 85,50) % Metoda wysokotemperaturowego spalania z detekcją IR Carbon content Range: (34,00 – 85,50) % High-temperature combustion method with IR detection","reference":"SW/ZLGIG/PB-11 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-11, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-11 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-11, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: mieszanki biopaliwa stałego z paliwem stałym, mieszanki stałego paliwa wtórnego z paliwem stałym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Zawartość węgla Zakres: (34,00 – 85,50) % Metoda wysokotemperaturowego spalania z detekcją IR Carbon content Range: (34,00 – 85,50) % High-temperature combustion method with IR detection SW/ZLGIG/PB-11 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-11, 2nd edition of 18 August 2025 Paliwa stale: mieszanki biopaliwa stalego z paliwem stalym, mieszanki stalego paliwa wtornego z paliwem stalym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Zawartosc wegla Zakres: (34,00 – 85,50) % Metoda wysokotemperaturowego spalania z detekcja IR Carbon content Range: (34,00 – 85,50) % High-temperature combustion method with IR detection SW/ZLGIG/PB-11 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-11, 2nd edition of 18 August 2025","categories":["petro"],"row_index":515,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Carbon content Range: (34,00 – 85,50) % High-temperature combustion method with IR detection SW/ZLGIG/PB-11 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-11, 2nd edition of 18 August 2025","search_zh":"固体燃料：固体生物燃料与固体燃料的混合物、固体再生燃料与固体燃料的混合物 Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel SW/ZLGIG/PB-11 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-11, 2nd edition of 18 August 2025","test_object_zh":"固体燃料：固体生物燃料与固体燃料的混合物、固体再生燃料与固体燃料的混合物 Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel"},{"_id":"6a5a55ef9af9f73f38250ca0","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: mieszanki biopaliwa stałego z paliwem stałym, mieszanki stałego paliwa wtórnego z paliwem stałym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel","test_object_en":"Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel","methodology":"Zawartość wodoru Zakres: (3,20 – 8,00) % Metoda wysokotemperaturowego spalania z detekcją IR Hydrogen content Range: (3,20 – 8,00) % High-temperature combustion method with IR detection","methodology_en":"Hydrogen content Range: (3,20 – 8,00) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wodoru Zakres: (3,20 – 8,00) % Metoda wysokotemperaturowego spalania z detekcją IR Hydrogen content Range: (3,20 – 8,00) % High-temperature combustion method with IR detection","reference":"SW/ZLGIG/PB-11 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-11, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-11 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-11, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: mieszanki biopaliwa stałego z paliwem stałym, mieszanki stałego paliwa wtórnego z paliwem stałym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Zawartość wodoru Zakres: (3,20 – 8,00) % Metoda wysokotemperaturowego spalania z detekcją IR Hydrogen content Range: (3,20 – 8,00) % High-temperature combustion method with IR detection SW/ZLGIG/PB-11 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-11, 2nd edition of 18 August 2025 Paliwa stale: mieszanki biopaliwa stalego z paliwem stalym, mieszanki stalego paliwa wtornego z paliwem stalym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Zawartosc wodoru Zakres: (3,20 – 8,00) % Metoda wysokotemperaturowego spalania z detekcja IR Hydrogen content Range: (3,20 – 8,00) % High-temperature combustion method with IR detection SW/ZLGIG/PB-11 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-11, 2nd edition of 18 August 2025","categories":["petro"],"row_index":516,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Hydrogen content Range: (3,20 – 8,00) % High-temperature combustion method with IR detection SW/ZLGIG/PB-11 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-11, 2nd edition of 18 August 2025","search_zh":"固体燃料：固体生物燃料与固体燃料的混合物、固体再生燃料与固体燃料的混合物 Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel SW/ZLGIG/PB-11 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-11, 2nd edition of 18 August 2025","test_object_zh":"固体燃料：固体生物燃料与固体燃料的混合物、固体再生燃料与固体燃料的混合物 Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel"},{"_id":"6a5a55ef9af9f73f38250ca1","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: mieszanki biopaliwa stałego z paliwem stałym, mieszanki stałego paliwa wtórnego z paliwem stałym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel","test_object_en":"Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel","methodology":"Zawartość azotu Zakres: (0,70 – 2,30) % Metoda wysokotemperaturowego spalania z detekcją TC Nitrogen content Range: (0,70 – 2,30) % High-temperature combustion method with TC detection","methodology_en":"Nitrogen content Range: (0,70 – 2,30) % High-temperature combustion method with TC detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość azotu Zakres: (0,70 – 2,30) % Metoda wysokotemperaturowego spalania z detekcją TC Nitrogen content Range: (0,70 – 2,30) % High-temperature combustion method with TC detection","reference":"SW/ZLGIG/PB-11 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-11, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-11 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-11, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: mieszanki biopaliwa stałego z paliwem stałym, mieszanki stałego paliwa wtórnego z paliwem stałym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Zawartość azotu Zakres: (0,70 – 2,30) % Metoda wysokotemperaturowego spalania z detekcją TC Nitrogen content Range: (0,70 – 2,30) % High-temperature combustion method with TC detection SW/ZLGIG/PB-11 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-11, 2nd edition of 18 August 2025 Paliwa stale: mieszanki biopaliwa stalego z paliwem stalym, mieszanki stalego paliwa wtornego z paliwem stalym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Zawartosc azotu Zakres: (0,70 – 2,30) % Metoda wysokotemperaturowego spalania z detekcja TC Nitrogen content Range: (0,70 – 2,30) % High-temperature combustion method with TC detection SW/ZLGIG/PB-11 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-11, 2nd edition of 18 August 2025","categories":["petro"],"row_index":517,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Nitrogen content Range: (0,70 – 2,30) % High-temperature combustion method with TC detection SW/ZLGIG/PB-11 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-11, 2nd edition of 18 August 2025","search_zh":"固体燃料：固体生物燃料与固体燃料的混合物、固体再生燃料与固体燃料的混合物 Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel SW/ZLGIG/PB-11 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-11, 2nd edition of 18 August 2025","test_object_zh":"固体燃料：固体生物燃料与固体燃料的混合物、固体再生燃料与固体燃料的混合物 Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel"},{"_id":"6a5a55ef9af9f73f38250ca2","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: mieszanki biopaliwa stałego z paliwem stałym, mieszanki stałego paliwa wtórnego z paliwem stałym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel","test_object_en":"Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel","methodology":"Zawartość siarki całkowitej Zakres: (0,50 – 2,20) % Metoda wysokotemperaturowego spalania z detekcją IR Total sulfur content Range: (0,50 – 2,20) % High-temperature combustion method with IR detection","methodology_en":"Total sulfur content Range: (0,50 – 2,20) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej Zakres: (0,50 – 2,20) % Metoda wysokotemperaturowego spalania z detekcją IR Total sulfur content Range: (0,50 – 2,20) % High-temperature combustion method with IR detection","reference":"SW/ZLGIG/PB-10 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-10, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-10 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-10, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: mieszanki biopaliwa stałego z paliwem stałym, mieszanki stałego paliwa wtórnego z paliwem stałym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Zawartość siarki całkowitej Zakres: (0,50 – 2,20) % Metoda wysokotemperaturowego spalania z detekcją IR Total sulfur content Range: (0,50 – 2,20) % High-temperature combustion method with IR detection SW/ZLGIG/PB-10 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-10, 2nd edition of 18 August 2025 Paliwa stale: mieszanki biopaliwa stalego z paliwem stalym, mieszanki stalego paliwa wtornego z paliwem stalym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Zawartosc siarki calkowitej Zakres: (0,50 – 2,20) % Metoda wysokotemperaturowego spalania z detekcja IR Total sulfur content Range: (0,50 – 2,20) % High-temperature combustion method with IR detection SW/ZLGIG/PB-10 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-10, 2nd edition of 18 August 2025","categories":["petro"],"row_index":518,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Total sulfur content Range: (0,50 – 2,20) % High-temperature combustion method with IR detection SW/ZLGIG/PB-10 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-10, 2nd edition of 18 August 2025","search_zh":"固体燃料：固体生物燃料与固体燃料的混合物、固体再生燃料与固体燃料的混合物 Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel SW/ZLGIG/PB-10 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-10, 2nd edition of 18 August 2025","test_object_zh":"固体燃料：固体生物燃料与固体燃料的混合物、固体再生燃料与固体燃料的混合物 Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel"},{"_id":"6a5a55ef9af9f73f38250ca3","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: mieszanki biopaliwa stałego z paliwem stałym, mieszanki stałego paliwa wtórnego z paliwem stałym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel","test_object_en":"Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel","methodology":"Zawartość części lotnych Zakres: (10,40 – 81,50) % Metoda wagowa Volatile matter content Range: (10,40 – 81,50) % Weight method","methodology_en":"Volatile matter content Range: (10,40 – 81,50) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość części lotnych Zakres: (10,40 – 81,50) % Metoda wagowa Volatile matter content Range: (10,40 – 81,50) % Weight method","reference":"SW/ZLGIG/PB-08 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-08, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-08 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-08, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: mieszanki biopaliwa stałego z paliwem stałym, mieszanki stałego paliwa wtórnego z paliwem stałym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Zawartość części lotnych Zakres: (10,40 – 81,50) % Metoda wagowa Volatile matter content Range: (10,40 – 81,50) % Weight method SW/ZLGIG/PB-08 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-08, 2nd edition of 18 August 2025 Paliwa stale: mieszanki biopaliwa stalego z paliwem stalym, mieszanki stalego paliwa wtornego z paliwem stalym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Zawartosc czesci lotnych Zakres: (10,40 – 81,50) % Metoda wagowa Volatile matter content Range: (10,40 – 81,50) % Weight method SW/ZLGIG/PB-08 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-08, 2nd edition of 18 August 2025","categories":["petro"],"row_index":519,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Volatile matter content Range: (10,40 – 81,50) % Weight method SW/ZLGIG/PB-08 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-08, 2nd edition of 18 August 2025","search_zh":"固体燃料：固体生物燃料与固体燃料的混合物、固体再生燃料与固体燃料的混合物 Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel SW/ZLGIG/PB-08 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-08, 2nd edition of 18 August 2025","test_object_zh":"固体燃料：固体生物燃料与固体燃料的混合物、固体再生燃料与固体燃料的混合物 Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel"},{"_id":"6a5a55ef9af9f73f38250ca4","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: mieszanki biopaliwa stałego z paliwem stałym, mieszanki stałego paliwa wtórnego z paliwem stałym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel","test_object_en":"Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel","methodology":"Ciepło spalania Zakres: (1200 – 31500) kJ/kg Metoda kalorymetryczna Gross calorific value Range: (1200 – 31500) kJ/kg Calorimetric method","methodology_en":"Gross calorific value Range: (1200 – 31500) kJ/kg Calorimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciepło spalania Zakres: (1200 – 31500) kJ/kg Metoda kalorymetryczna Gross calorific value Range: (1200 – 31500) kJ/kg Calorimetric method","reference":"SW/ZLGIG/PB-09 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-09, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-09 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-09, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: mieszanki biopaliwa stałego z paliwem stałym, mieszanki stałego paliwa wtórnego z paliwem stałym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Ciepło spalania Zakres: (1200 – 31500) kJ/kg Metoda kalorymetryczna Gross calorific value Range: (1200 – 31500) kJ/kg Calorimetric method SW/ZLGIG/PB-09 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-09, 2nd edition of 18 August 2025 Paliwa stale: mieszanki biopaliwa stalego z paliwem stalym, mieszanki stalego paliwa wtornego z paliwem stalym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Cieplo spalania Zakres: (1200 – 31500) kJ/kg Metoda kalorymetryczna Gross calorific value Range: (1200 – 31500) kJ/kg Calorimetric method SW/ZLGIG/PB-09 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-09, 2nd edition of 18 August 2025","categories":["petro"],"row_index":520,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Gross calorific value Range: (1200 – 31500) kJ/kg Calorimetric method SW/ZLGIG/PB-09 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-09, 2nd edition of 18 August 2025","search_zh":"固体燃料：固体生物燃料与固体燃料的混合物、固体再生燃料与固体燃料的混合物 Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel SW/ZLGIG/PB-09 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-09, 2nd edition of 18 August 2025","test_object_zh":"固体燃料：固体生物燃料与固体燃料的混合物、固体再生燃料与固体燃料的混合物 Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel"},{"_id":"6a5a55ef9af9f73f38250ca5","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: mieszanki biopaliwa stałego z paliwem stałym, mieszanki stałego paliwa wtórnego z paliwem stałym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel","test_object_en":"Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel","methodology":"Wartość opałowa (z obliczeń) Net calorific value (from calculations)","methodology_en":"Net calorific value (calculated) Net calorific value (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wartość opałowa (z obliczeń) Net calorific value (from calculations)","reference":"SW/ZLGIG/PB-09 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-09, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-09 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-09, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: mieszanki biopaliwa stałego z paliwem stałym, mieszanki stałego paliwa wtórnego z paliwem stałym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Wartość opałowa (z obliczeń) Net calorific value (from calculations) SW/ZLGIG/PB-09 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-09, 2nd edition of 18 August 2025 Paliwa stale: mieszanki biopaliwa stalego z paliwem stalym, mieszanki stalego paliwa wtornego z paliwem stalym Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Wartosc opalowa (z obliczen) Net calorific value (from calculations) SW/ZLGIG/PB-09 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-09, 2nd edition of 18 August 2025","categories":["petro"],"row_index":521,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel Net calorific value (calculated) Net calorific value (from calculations) SW/ZLGIG/PB-09 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-09, 2nd edition of 18 August 2025","search_zh":"固体燃料：固体生物燃料与固体燃料的混合物、固体再生燃料与固体燃料的混合物 Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel 低位发热量（由计算得出） Net calorific value (from calculations) SW/ZLGIG/PB-09 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-09, 2nd edition of 18 August 2025","test_object_zh":"固体燃料：固体生物燃料与固体燃料的混合物、固体再生燃料与固体燃料的混合物 Solid fuels: mixture of solid biofuel with solid fuel, mixture of solid recovered fuel with solid fuel","methodology_zh":"低位发热量（由计算得出） Net calorific value (from calculations)"},{"_id":"6a5a55ef9af9f73f38250ca6","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, koks z węgla kamiennego, karbionizat z węgla kamiennego Solid fuels: hard coal, coke from hard coal char from hard coal","test_object_en":"Solid fuels: hard coal, coke from hard coal char from hard coal","methodology":"Zawartość wilgoci przemijającej Zakres: (0,03 – 18,90) % Metoda wagowa Transient moisture Range: (0,03 – 18,90) % Weight method","methodology_en":"Transient moisture Range: (0,03 – 18,90) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci przemijającej Zakres: (0,03 – 18,90) % Metoda wagowa Transient moisture Range: (0,03 – 18,90) % Weight method","reference":"PN-G-04611:2020-06","norm_bases":["PN-G-04611:2020-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, koks z węgla kamiennego, karbionizat z węgla kamiennego Solid fuels: hard coal, coke from hard coal char from hard coal Zawartość wilgoci przemijającej Zakres: (0,03 – 18,90) % Metoda wagowa Transient moisture Range: (0,03 – 18,90) % Weight method PN-G-04611:2020-06 Paliwa stale: wegiel kamienny, koks z wegla kamiennego, karbionizat z wegla kamiennego Solid fuels: hard coal, coke from hard coal char from hard coal Zawartosc wilgoci przemijajacej Zakres: (0,03 – 18,90) % Metoda wagowa Transient moisture Range: (0,03 – 18,90) % Weight method PN-G-04611:2020-06","categories":["petro"],"row_index":522,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal, coke from hard coal char from hard coal Transient moisture Range: (0,03 – 18,90) % Weight method PN-G-04611:2020-06","search_zh":"固体燃料：烟煤、烟煤焦炭、烟煤半焦 Solid fuels: hard coal, coke from hard coal char from hard coal PN-G-04611:2020-06","test_object_zh":"固体燃料：烟煤、烟煤焦炭、烟煤半焦 Solid fuels: hard coal, coke from hard coal char from hard coal"},{"_id":"6a5a55ef9af9f73f38250ca7","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, koks z węgla kamiennego, karbionizat z węgla kamiennego Solid fuels: hard coal, coke from hard coal char from hard coal","test_object_en":"Solid fuels: hard coal, coke from hard coal char from hard coal","methodology":"Zawartość wilgoci analitycznej Zakres (0,10 – 8,80) % Metoda wagowa Analytical moisture content Range: (0,10 – 8,80) % Weight method","methodology_en":"Analytical moisture content Range: (0,10 – 8,80) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci analitycznej Zakres (0,10 – 8,80) % Metoda wagowa Analytical moisture content Range: (0,10 – 8,80) % Weight method","reference":"PN-G-04611:2020-06","norm_bases":["PN-G-04611:2020-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, koks z węgla kamiennego, karbionizat z węgla kamiennego Solid fuels: hard coal, coke from hard coal char from hard coal Zawartość wilgoci analitycznej Zakres (0,10 – 8,80) % Metoda wagowa Analytical moisture content Range: (0,10 – 8,80) % Weight method PN-G-04611:2020-06 Paliwa stale: wegiel kamienny, koks z wegla kamiennego, karbionizat z wegla kamiennego Solid fuels: hard coal, coke from hard coal char from hard coal Zawartosc wilgoci analitycznej Zakres (0,10 – 8,80) % Metoda wagowa Analytical moisture content Range: (0,10 – 8,80) % Weight method PN-G-04611:2020-06","categories":["petro"],"row_index":523,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal, coke from hard coal char from hard coal Analytical moisture content Range: (0,10 – 8,80) % Weight method PN-G-04611:2020-06","search_zh":"固体燃料：烟煤、烟煤焦炭、烟煤半焦 Solid fuels: hard coal, coke from hard coal char from hard coal PN-G-04611:2020-06","test_object_zh":"固体燃料：烟煤、烟煤焦炭、烟煤半焦 Solid fuels: hard coal, coke from hard coal char from hard coal"},{"_id":"6a5a55ef9af9f73f38250ca8","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, koks z węgla kamiennego, karbionizat z węgla kamiennego Solid fuels: hard coal, coke from hard coal char from hard coal","test_object_en":"Solid fuels: hard coal, coke from hard coal char from hard coal","methodology":"Zawartość wilgoci całkowitej (z obliczeń) Total moisture content (from calculations)","methodology_en":"Total moisture content (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej (z obliczeń) Total moisture content (from calculations)","reference":"PN-G-04611:2020-06","norm_bases":["PN-G-04611:2020-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, koks z węgla kamiennego, karbionizat z węgla kamiennego Solid fuels: hard coal, coke from hard coal char from hard coal Zawartość wilgoci całkowitej (z obliczeń) Total moisture content (from calculations) PN-G-04611:2020-06 Paliwa stale: wegiel kamienny, koks z wegla kamiennego, karbionizat z wegla kamiennego Solid fuels: hard coal, coke from hard coal char from hard coal Zawartosc wilgoci calkowitej (z obliczen) Total moisture content (from calculations) PN-G-04611:2020-06","categories":["petro"],"row_index":524,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal, coke from hard coal char from hard coal Total moisture content (from calculations) PN-G-04611:2020-06","methodology_zh":"全水分含量（由计算得出） Total moisture content (from calculations)","search_zh":"固体燃料：烟煤、烟煤焦炭、烟煤半焦 Solid fuels: hard coal, coke from hard coal char from hard coal 全水分含量（由计算得出） Total moisture content (from calculations) PN-G-04611:2020-06","test_object_zh":"固体燃料：烟煤、烟煤焦炭、烟煤半焦 Solid fuels: hard coal, coke from hard coal char from hard coal"},{"_id":"6a5a55ef9af9f73f38250ca9","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels","test_object_en":"Solid fuels: solid recovered fuels","methodology":"Zawartość wilgoci przemijającej Zakres: (2,40 – 25,60) % Metoda wagowa Transient moisture Range: (2,40 – 25,60) % Weight method","methodology_en":"Transient moisture Range: (2,40 – 25,60) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci przemijającej Zakres: (2,40 – 25,60) % Metoda wagowa Transient moisture Range: (2,40 – 25,60) % Weight method","reference":"SW/ZLGIG/PB-03 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-03, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-03 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-03, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels Zawartość wilgoci przemijającej Zakres: (2,40 – 25,60) % Metoda wagowa Transient moisture Range: (2,40 – 25,60) % Weight method SW/ZLGIG/PB-03 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-03, 2nd edition of 18 August 2025 Paliwa stale: stale paliwa wtorne Solid fuels: solid recovered fuels Zawartosc wilgoci przemijajacej Zakres: (2,40 – 25,60) % Metoda wagowa Transient moisture Range: (2,40 – 25,60) % Weight method SW/ZLGIG/PB-03 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-03, 2nd edition of 18 August 2025","categories":["petro"],"row_index":525,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid recovered fuels Transient moisture Range: (2,40 – 25,60) % Weight method SW/ZLGIG/PB-03 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-03, 2nd edition of 18 August 2025","search_zh":"固体燃料：固体回收燃料 SW/ZLGIG/PB-03 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-03, 2nd edition of 18 August 2025","test_object_zh":"固体燃料：固体回收燃料"},{"_id":"6a5a55ef9af9f73f38250caa","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels","test_object_en":"Solid fuels: solid recovered fuels","methodology":"Zawartość wilgoci w próbce analitycznej Zakres: (0,50 – 9,20) % Metoda termograwimetryczna (TGA) Moisture content in analytical sample Range: (0,50 – 9,20) % Thermogravimetric method (TGA)","methodology_en":"Moisture content in analytical sample Range: (0,50 – 9,20) % Thermogravimetric method (TGA)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej Zakres: (0,50 – 9,20) % Metoda termograwimetryczna (TGA) Moisture content in analytical sample Range: (0,50 – 9,20) % Thermogravimetric method (TGA)","reference":"PN-EN ISO 21660-3:2021-08","norm_bases":["PN-EN ISO 21660-3:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels Zawartość wilgoci w próbce analitycznej Zakres: (0,50 – 9,20) % Metoda termograwimetryczna (TGA) Moisture content in analytical sample Range: (0,50 – 9,20) % Thermogravimetric method (TGA) PN-EN ISO 21660-3:2021-08 Paliwa stale: stale paliwa wtorne Solid fuels: solid recovered fuels Zawartosc wilgoci w probce analitycznej Zakres: (0,50 – 9,20) % Metoda termograwimetryczna (TGA) Moisture content in analytical sample Range: (0,50 – 9,20) % Thermogravimetric method (TGA) PN-EN ISO 21660-3:2021-08","categories":["petro"],"row_index":526,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid recovered fuels Moisture content in analytical sample Range: (0,50 – 9,20) % Thermogravimetric method (TGA) PN-EN ISO 21660-3:2021-08","search_zh":"固体燃料：固体回收燃料 PN-EN ISO 21660-3:2021-08","test_object_zh":"固体燃料：固体回收燃料"},{"_id":"6a5a55ef9af9f73f38250cab","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels","test_object_en":"Solid fuels: solid recovered fuels","methodology":"Zawartość wilgoci w próbce analitycznej Zakres: (0,50 – 9,00) % Metoda wagowa Moisture content in analytical sample Range: (0,50 – 9,00) % Weight method","methodology_en":"Moisture content in analytical sample Range: (0,50 – 9,00) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej Zakres: (0,50 – 9,00) % Metoda wagowa Moisture content in analytical sample Range: (0,50 – 9,00) % Weight method","reference":"PN-EN ISO 21660-3:2021-08","norm_bases":["PN-EN ISO 21660-3:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels Zawartość wilgoci w próbce analitycznej Zakres: (0,50 – 9,00) % Metoda wagowa Moisture content in analytical sample Range: (0,50 – 9,00) % Weight method PN-EN ISO 21660-3:2021-08 Paliwa stale: stale paliwa wtorne Solid fuels: solid recovered fuels Zawartosc wilgoci w probce analitycznej Zakres: (0,50 – 9,00) % Metoda wagowa Moisture content in analytical sample Range: (0,50 – 9,00) % Weight method PN-EN ISO 21660-3:2021-08","categories":["petro"],"row_index":527,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid recovered fuels Moisture content in analytical sample Range: (0,50 – 9,00) % Weight method PN-EN ISO 21660-3:2021-08","search_zh":"固体燃料：固体回收燃料 PN-EN ISO 21660-3:2021-08","test_object_zh":"固体燃料：固体回收燃料"},{"_id":"6a5a55ef9af9f73f38250cac","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels","test_object_en":"Solid fuels: solid recovered fuels","methodology":"Zawartość wilgoci całkowitej (z obliczeń) Total moisture content (from calculations)","methodology_en":"Total moisture content (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej (z obliczeń) Total moisture content (from calculations)","reference":"SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels Zawartość wilgoci całkowitej (z obliczeń) Total moisture content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025 Paliwa stale: stale paliwa wtorne Solid fuels: solid recovered fuels Zawartosc wilgoci calkowitej (z obliczen) Total moisture content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","categories":["petro"],"row_index":528,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid recovered fuels Total moisture content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","search_zh":"固体燃料：固体回收燃料 全水分含量（由计算得出） Total moisture content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","test_object_zh":"固体燃料：固体回收燃料","methodology_zh":"全水分含量（由计算得出） Total moisture content (from calculations)"},{"_id":"6a5a55ef9af9f73f38250cad","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels","test_object_en":"Solid fuels: solid recovered fuels","methodology":"Zawartość popiołu Zakres: (13,50 – 63,50) % Metoda termograwimetryczna (TGA) Ash content Range: (13,50 – 63,50) % Thermogravimetric method (TGA)","methodology_en":"Ash content Range: (13,50 – 63,50) % Thermogravimetric method (TGA)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość popiołu Zakres: (13,50 – 63,50) % Metoda termograwimetryczna (TGA) Ash content Range: (13,50 – 63,50) % Thermogravimetric method (TGA)","reference":"PN-EN ISO 21656:2021-08","norm_bases":["PN-EN ISO 21656:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels Zawartość popiołu Zakres: (13,50 – 63,50) % Metoda termograwimetryczna (TGA) Ash content Range: (13,50 – 63,50) % Thermogravimetric method (TGA) PN-EN ISO 21656:2021-08 Paliwa stale: stale paliwa wtorne Solid fuels: solid recovered fuels Zawartosc popiolu Zakres: (13,50 – 63,50) % Metoda termograwimetryczna (TGA) Ash content Range: (13,50 – 63,50) % Thermogravimetric method (TGA) PN-EN ISO 21656:2021-08","categories":["petro"],"row_index":529,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid recovered fuels Ash content Range: (13,50 – 63,50) % Thermogravimetric method (TGA) PN-EN ISO 21656:2021-08","search_zh":"固体燃料：固体回收燃料 PN-EN ISO 21656:2021-08","test_object_zh":"固体燃料：固体回收燃料"},{"_id":"6a5a55ef9af9f73f38250cae","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels","test_object_en":"Solid fuels: solid recovered fuels","methodology":"Zawartość popiołu Zakres: (12,60 – 64,00) % Metoda wagowa (powolnego spopielania) Ash content Range: (12,60 – 64,00) % Weight method (slow burning)","methodology_en":"Ash content Range: (12,60 – 64,00) % Weight method (slow burning)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość popiołu Zakres: (12,60 – 64,00) % Metoda wagowa (powolnego spopielania) Ash content Range: (12,60 – 64,00) % Weight method (slow burning)","reference":"PN-EN ISO 21656:2021-08","norm_bases":["PN-EN ISO 21656:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels Zawartość popiołu Zakres: (12,60 – 64,00) % Metoda wagowa (powolnego spopielania) Ash content Range: (12,60 – 64,00) % Weight method (slow burning) PN-EN ISO 21656:2021-08 Paliwa stale: stale paliwa wtorne Solid fuels: solid recovered fuels Zawartosc popiolu Zakres: (12,60 – 64,00) % Metoda wagowa (powolnego spopielania) Ash content Range: (12,60 – 64,00) % Weight method (slow burning) PN-EN ISO 21656:2021-08","categories":["petro"],"row_index":530,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid recovered fuels Ash content Range: (12,60 – 64,00) % Weight method (slow burning) PN-EN ISO 21656:2021-08","search_zh":"固体燃料：固体回收燃料 PN-EN ISO 21656:2021-08","test_object_zh":"固体燃料：固体回收燃料"},{"_id":"6a5a55ef9af9f73f38250caf","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels","test_object_en":"Solid fuels: solid recovered fuels","methodology":"Zawartość węgla Zakres: (33,00 – 72,00) % Metoda wysokotemperaturowego spalania z detekcją IR Carbon content Range: (33,00 – 72,00)% High-temperature combustion method with IR detection","methodology_en":"Carbon content Range: (33,00 – 72,00)% High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość węgla Zakres: (33,00 – 72,00) % Metoda wysokotemperaturowego spalania z detekcją IR Carbon content Range: (33,00 – 72,00)% High-temperature combustion method with IR detection","reference":"PN-EN ISO 21663:2021-06","norm_bases":["PN-EN ISO 21663:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels Zawartość węgla Zakres: (33,00 – 72,00) % Metoda wysokotemperaturowego spalania z detekcją IR Carbon content Range: (33,00 – 72,00)% High-temperature combustion method with IR detection PN-EN ISO 21663:2021-06 Paliwa stale: stale paliwa wtorne Solid fuels: solid recovered fuels Zawartosc wegla Zakres: (33,00 – 72,00) % Metoda wysokotemperaturowego spalania z detekcja IR Carbon content Range: (33,00 – 72,00)% High-temperature combustion method with IR detection PN-EN ISO 21663:2021-06","categories":["petro"],"row_index":531,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid recovered fuels Carbon content Range: (33,00 – 72,00)% High-temperature combustion method with IR detection PN-EN ISO 21663:2021-06","search_zh":"固体燃料：固体回收燃料 PN-EN ISO 21663:2021-06","test_object_zh":"固体燃料：固体回收燃料"},{"_id":"6a5a55ef9af9f73f38250cb0","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels","test_object_en":"Solid fuels: solid recovered fuels","methodology":"Zawartość wodoru Zakres: (0,40 – 9,50) % Metoda wysokotemperaturowego spalania z detekcją IR Hydrogen content Range: (0,40 – 9,50) % High-temperature combustion method with IR detection","methodology_en":"Hydrogen content Range: (0,40 – 9,50) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wodoru Zakres: (0,40 – 9,50) % Metoda wysokotemperaturowego spalania z detekcją IR Hydrogen content Range: (0,40 – 9,50) % High-temperature combustion method with IR detection","reference":"PN-EN ISO 21663:2021-06","norm_bases":["PN-EN ISO 21663:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels Zawartość wodoru Zakres: (0,40 – 9,50) % Metoda wysokotemperaturowego spalania z detekcją IR Hydrogen content Range: (0,40 – 9,50) % High-temperature combustion method with IR detection PN-EN ISO 21663:2021-06 Paliwa stale: stale paliwa wtorne Solid fuels: solid recovered fuels Zawartosc wodoru Zakres: (0,40 – 9,50) % Metoda wysokotemperaturowego spalania z detekcja IR Hydrogen content Range: (0,40 – 9,50) % High-temperature combustion method with IR detection PN-EN ISO 21663:2021-06","categories":["petro"],"row_index":532,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid recovered fuels Hydrogen content Range: (0,40 – 9,50) % High-temperature combustion method with IR detection PN-EN ISO 21663:2021-06","search_zh":"固体燃料：固体回收燃料 PN-EN ISO 21663:2021-06","test_object_zh":"固体燃料：固体回收燃料"},{"_id":"6a5a55ef9af9f73f38250cb1","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels","test_object_en":"Solid fuels: solid recovered fuels","methodology":"Zawartość azotu Zakres: (0,10 – 1,50) % Metoda wysokotemperaturowego spalania z detekcją TC Nitrogen content Range: (0,10 – 1,50) % High-temperature combustion method with TC detection","methodology_en":"Nitrogen content Range: (0,10 – 1,50) % High-temperature combustion method with TC detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość azotu Zakres: (0,10 – 1,50) % Metoda wysokotemperaturowego spalania z detekcją TC Nitrogen content Range: (0,10 – 1,50) % High-temperature combustion method with TC detection","reference":"PN-EN ISO 21663:2021-06","norm_bases":["PN-EN ISO 21663:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels Zawartość azotu Zakres: (0,10 – 1,50) % Metoda wysokotemperaturowego spalania z detekcją TC Nitrogen content Range: (0,10 – 1,50) % High-temperature combustion method with TC detection PN-EN ISO 21663:2021-06 Paliwa stale: stale paliwa wtorne Solid fuels: solid recovered fuels Zawartosc azotu Zakres: (0,10 – 1,50) % Metoda wysokotemperaturowego spalania z detekcja TC Nitrogen content Range: (0,10 – 1,50) % High-temperature combustion method with TC detection PN-EN ISO 21663:2021-06","categories":["petro"],"row_index":533,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid recovered fuels Nitrogen content Range: (0,10 – 1,50) % High-temperature combustion method with TC detection PN-EN ISO 21663:2021-06","search_zh":"固体燃料：固体回收燃料 PN-EN ISO 21663:2021-06","test_object_zh":"固体燃料：固体回收燃料"},{"_id":"6a5a55ef9af9f73f38250cb2","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels","test_object_en":"Solid fuels: solid recovered fuels","methodology":"Zawartość tlenu (z obliczeń) Oxygen content (from calculations)","methodology_en":"Oxygen content (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość tlenu (z obliczeń) Oxygen content (from calculations)","reference":"SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels Zawartość tlenu (z obliczeń) Oxygen content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025 Paliwa stale: stale paliwa wtorne Solid fuels: solid recovered fuels Zawartosc tlenu (z obliczen) Oxygen content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","categories":["petro"],"row_index":534,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid recovered fuels Oxygen content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","search_zh":"固体燃料：固体回收燃料 氧含量（由计算得出） Oxygen content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","test_object_zh":"固体燃料：固体回收燃料","methodology_zh":"氧含量（由计算得出） Oxygen content (from calculations)"},{"_id":"6a5a55ef9af9f73f38250cb3","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels","test_object_en":"Solid fuels: solid recovered fuels","methodology":"Zawartość siarki całkowitej Zakres: (0,05 – 0,80) % Metoda wysokotemperaturowego spalania z detekcją IR Total sulfur content Range: (0,05 – 0,80)% High-temperature combustion method with IR detection","methodology_en":"Total sulfur content Range: (0,05 – 0,80)% High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej Zakres: (0,05 – 0,80) % Metoda wysokotemperaturowego spalania z detekcją IR Total sulfur content Range: (0,05 – 0,80)% High-temperature combustion method with IR detection","reference":"PN-EN ISO 21663:2021-06","norm_bases":["PN-EN ISO 21663:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels Zawartość siarki całkowitej Zakres: (0,05 – 0,80) % Metoda wysokotemperaturowego spalania z detekcją IR Total sulfur content Range: (0,05 – 0,80)% High-temperature combustion method with IR detection PN-EN ISO 21663:2021-06 Paliwa stale: stale paliwa wtorne Solid fuels: solid recovered fuels Zawartosc siarki calkowitej Zakres: (0,05 – 0,80) % Metoda wysokotemperaturowego spalania z detekcja IR Total sulfur content Range: (0,05 – 0,80)% High-temperature combustion method with IR detection PN-EN ISO 21663:2021-06","categories":["petro"],"row_index":535,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid recovered fuels Total sulfur content Range: (0,05 – 0,80)% High-temperature combustion method with IR detection PN-EN ISO 21663:2021-06","search_zh":"固体燃料：固体回收燃料 PN-EN ISO 21663:2021-06","test_object_zh":"固体燃料：固体回收燃料"},{"_id":"6a5a55ef9af9f73f38250cb4","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels","test_object_en":"Solid fuels: solid recovered fuels","methodology":"Zawartość siarki palnej i popiołowej (z obliczeń) Combustible sulphur and ash sulpfur content (calculated)","methodology_en":"Combustible sulphur and ash sulpfur content (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość siarki palnej i popiołowej (z obliczeń) Combustible sulphur and ash sulpfur content (calculated)","reference":"SW/ZLGIG/PB-10 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-10, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-10 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-10, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels Zawartość siarki palnej i popiołowej (z obliczeń) Combustible sulphur and ash sulpfur content (calculated) SW/ZLGIG/PB-10 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-10, 2nd edition of 18 August 2025 Paliwa stale: stale paliwa wtorne Solid fuels: solid recovered fuels Zawartosc siarki palnej i popiolowej (z obliczen) Combustible sulphur and ash sulpfur content (calculated) SW/ZLGIG/PB-10 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-10, 2nd edition of 18 August 2025","categories":["petro"],"row_index":536,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid recovered fuels Combustible sulphur and ash sulpfur content (calculated) SW/ZLGIG/PB-10 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-10, 2nd edition of 18 August 2025","search_zh":"固体燃料：固体回收燃料 SW/ZLGIG/PB-10 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-10, 2nd edition of 18 August 2025","test_object_zh":"固体燃料：固体回收燃料"},{"_id":"6a5a55ef9af9f73f38250cb5","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels","test_object_en":"Solid fuels: solid recovered fuels","methodology":"Zawartość części lotnych Zakres: (55,35 – 65,40) % Metoda wagowa Volatile matter content Range: (55,35 – 65,40) % Weight method","methodology_en":"Volatile matter content Range: (55,35 – 65,40) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość części lotnych Zakres: (55,35 – 65,40) % Metoda wagowa Volatile matter content Range: (55,35 – 65,40) % Weight method","reference":"PN-EN ISO 22167:2021-08","norm_bases":["PN-EN ISO 22167:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels Zawartość części lotnych Zakres: (55,35 – 65,40) % Metoda wagowa Volatile matter content Range: (55,35 – 65,40) % Weight method PN-EN ISO 22167:2021-08 Paliwa stale: stale paliwa wtorne Solid fuels: solid recovered fuels Zawartosc czesci lotnych Zakres: (55,35 – 65,40) % Metoda wagowa Volatile matter content Range: (55,35 – 65,40) % Weight method PN-EN ISO 22167:2021-08","categories":["petro"],"row_index":537,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid recovered fuels Volatile matter content Range: (55,35 – 65,40) % Weight method PN-EN ISO 22167:2021-08","search_zh":"固体燃料：固体回收燃料 PN-EN ISO 22167:2021-08","test_object_zh":"固体燃料：固体回收燃料"},{"_id":"6a5a55ef9af9f73f38250cb6","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels","test_object_en":"Solid fuels: solid recovered fuels","methodology":"Ciepło spalania Zakres: (14735 – 31800) kJ/kg Metoda kalorymetryczna Gross calorific value Range: (14735–31800) kJ/kg Calorimetric method","methodology_en":"Gross calorific value Range: (14735–31800) kJ/kg Calorimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciepło spalania Zakres: (14735 – 31800) kJ/kg Metoda kalorymetryczna Gross calorific value Range: (14735–31800) kJ/kg Calorimetric method","reference":"PN-EN ISO 21654:2021-12","norm_bases":["PN-EN ISO 21654:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels Ciepło spalania Zakres: (14735 – 31800) kJ/kg Metoda kalorymetryczna Gross calorific value Range: (14735–31800) kJ/kg Calorimetric method PN-EN ISO 21654:2021-12 Paliwa stale: stale paliwa wtorne Solid fuels: solid recovered fuels Cieplo spalania Zakres: (14735 – 31800) kJ/kg Metoda kalorymetryczna Gross calorific value Range: (14735–31800) kJ/kg Calorimetric method PN-EN ISO 21654:2021-12","categories":["petro"],"row_index":538,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid recovered fuels Gross calorific value Range: (14735–31800) kJ/kg Calorimetric method PN-EN ISO 21654:2021-12","search_zh":"固体燃料：固体回收燃料 PN-EN ISO 21654:2021-12","test_object_zh":"固体燃料：固体回收燃料"},{"_id":"6a5a55ef9af9f73f38250cb7","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels","test_object_en":"Solid fuels: solid recovered fuels","methodology":"Wartość opałowa (z obliczeń) Net calorific value (from calculations)","methodology_en":"Net calorific value (calculated) Net calorific value (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wartość opałowa (z obliczeń) Net calorific value (from calculations)","reference":"PN-EN ISO 21654:2021-12","norm_bases":["PN-EN ISO 21654:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels Wartość opałowa (z obliczeń) Net calorific value (from calculations) PN-EN ISO 21654:2021-12 Paliwa stale: stale paliwa wtorne Solid fuels: solid recovered fuels Wartosc opalowa (z obliczen) Net calorific value (from calculations) PN-EN ISO 21654:2021-12","categories":["petro"],"row_index":539,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid recovered fuels Net calorific value (calculated) Net calorific value (from calculations) PN-EN ISO 21654:2021-12","search_zh":"固体燃料：固体回收燃料 低位发热量（由计算得出） Net calorific value (from calculations) PN-EN ISO 21654:2021-12","test_object_zh":"固体燃料：固体回收燃料","methodology_zh":"低位发热量（由计算得出） Net calorific value (from calculations)"},{"_id":"6a5a55ef9af9f73f38250cb8","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels","test_object_en":"Solid fuels: solid recovered fuels","methodology":"Zawartość frakcji biodegradowalnej – udział masowy biomasy Zawartość frakcji nie biodegradowalnej – udział masowy niebiomasy Zakres: (1,80 – 89,50) % Metoda wagowa Biodegradable fraction content – mass fraction of biomass Non-biodegradable fraction content – mass fraction of non-biomass Range: (1,80 – 89,50) % Weight method","methodology_en":"Biodegradable fraction content – mass fraction of biomass Non-biodegradable fraction content – mass fraction of non-biomass Range: (1,80 – 89,50) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość frakcji biodegradowalnej – udział masowy biomasy Zawartość frakcji nie biodegradowalnej – udział masowy niebiomasy Zakres: (1,80 – 89,50) % Metoda wagowa Biodegradable fraction content – mass fraction of biomass Non-biodegradable fraction content – mass fraction of non-biomass Range: (1,80 – 89,50) % Weight method","reference":"PN-EN 21644:2021-07","norm_bases":["PN-EN 21644:2021-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels Zawartość frakcji biodegradowalnej – udział masowy biomasy Zawartość frakcji nie biodegradowalnej – udział masowy niebiomasy Zakres: (1,80 – 89,50) % Metoda wagowa Biodegradable fraction content – mass fraction of biomass Non-biodegradable fraction content – mass fraction of non-biomass Range: (1,80 – 89,50) % Weight method PN-EN 21644:2021-07 Paliwa stale: stale paliwa wtorne Solid fuels: solid recovered fuels Zawartosc frakcji biodegradowalnej – udzial masowy biomasy Zawartosc frakcji nie biodegradowalnej – udzial masowy niebiomasy Zakres: (1,80 – 89,50) % Metoda wagowa Biodegradable fraction content – mass fraction of biomass Non-biodegradable fraction content – mass fraction of non-biomass Range: (1,80 – 89,50) % Weight method PN-EN 21644:2021-07","categories":["petro"],"row_index":540,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid recovered fuels Biodegradable fraction content – mass fraction of biomass Non-biodegradable fraction content – mass fraction of non-biomass Range: (1,80 – 89,50) % Weight method PN-EN 21644:2021-07","search_zh":"固体燃料：固体回收燃料 PN-EN 21644:2021-07","test_object_zh":"固体燃料：固体回收燃料"},{"_id":"6a5a55ef9af9f73f38250cb9","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels","test_object_en":"Solid fuels: solid recovered fuels","methodology":"Zawartość chloru Zakres: (0,112 – 3,221) % Metoda miareczkowa Chlorine content Range: (0,112 – 3,221) % Titration method","methodology_en":"Chlorine content Range: (0,112 – 3,221) % Titration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość chloru Zakres: (0,112 – 3,221) % Metoda miareczkowa Chlorine content Range: (0,112 – 3,221) % Titration method","reference":"SW/ZLGIG/PB-13 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-13, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-13 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-13, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels Zawartość chloru Zakres: (0,112 – 3,221) % Metoda miareczkowa Chlorine content Range: (0,112 – 3,221) % Titration method SW/ZLGIG/PB-13 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-13, 2nd edition of 18 August 2025 Paliwa stale: stale paliwa wtorne Solid fuels: solid recovered fuels Zawartosc chloru Zakres: (0,112 – 3,221) % Metoda miareczkowa Chlorine content Range: (0,112 – 3,221) % Titration method SW/ZLGIG/PB-13 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-13, 2nd edition of 18 August 2025","categories":["petro"],"row_index":541,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid recovered fuels Chlorine content Range: (0,112 – 3,221) % Titration method SW/ZLGIG/PB-13 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-13, 2nd edition of 18 August 2025","search_zh":"固体燃料：固体回收燃料 SW/ZLGIG/PB-13 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-13, 2nd edition of 18 August 2025","test_object_zh":"固体燃料：固体回收燃料"},{"_id":"6a5a55ef9af9f73f38250cba","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels","test_object_en":"Solid fuels: solid recovered fuels","methodology":"Zawartość chloru Zakres: (0,070 – 4,300) % Metoda wysokotemperaturowego spalania z detekcją kulometryczną Chlorine content Range: (0,070 – 4,300) % High-temperature combustion method with coulometric detection","methodology_en":"Chlorine content Range: (0,070 – 4,300) % High-temperature combustion method with coulometric detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość chloru Zakres: (0,070 – 4,300) % Metoda wysokotemperaturowego spalania z detekcją kulometryczną Chlorine content Range: (0,070 – 4,300) % High-temperature combustion method with coulometric detection","reference":"SW/ZLGIG/PB-12 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-12, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-12 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-12, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwa wtórne Solid fuels: solid recovered fuels Zawartość chloru Zakres: (0,070 – 4,300) % Metoda wysokotemperaturowego spalania z detekcją kulometryczną Chlorine content Range: (0,070 – 4,300) % High-temperature combustion method with coulometric detection SW/ZLGIG/PB-12 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-12, 2nd edition of 18 August 2025 Paliwa stale: stale paliwa wtorne Solid fuels: solid recovered fuels Zawartosc chloru Zakres: (0,070 – 4,300) % Metoda wysokotemperaturowego spalania z detekcja kulometryczna Chlorine content Range: (0,070 – 4,300) % High-temperature combustion method with coulometric detection SW/ZLGIG/PB-12 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-12, 2nd edition of 18 August 2025","categories":["petro"],"row_index":542,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid recovered fuels Chlorine content Range: (0,070 – 4,300) % High-temperature combustion method with coulometric detection SW/ZLGIG/PB-12 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-12, 2nd edition of 18 August 2025","search_zh":"固体燃料：固体回收燃料 SW/ZLGIG/PB-12 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-12, 2nd edition of 18 August 2025","test_object_zh":"固体燃料：固体回收燃料"},{"_id":"6a5a55ef9af9f73f38250cbb","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel","test_object_en":"Solid fuels: solid biofuel","methodology":"Zawartość wilgoci przemijającej Zakres (3,60 – 36,60) % Metoda wagowa Transient moisture Range: (3,60 – 36,60) % Weight method","methodology_en":"Transient moisture Range: (3,60 – 36,60) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci przemijającej Zakres (3,60 – 36,60) % Metoda wagowa Transient moisture Range: (3,60 – 36,60) % Weight method","reference":"SW/ZLGIG/PB-03 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-03, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-03 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-03, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel Zawartość wilgoci przemijającej Zakres (3,60 – 36,60) % Metoda wagowa Transient moisture Range: (3,60 – 36,60) % Weight method SW/ZLGIG/PB-03 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-03, 2nd edition of 18 August 2025 Paliwa stale: biopaliwa stale Solid fuels: solid biofuel Zawartosc wilgoci przemijajacej Zakres (3,60 – 36,60) % Metoda wagowa Transient moisture Range: (3,60 – 36,60) % Weight method SW/ZLGIG/PB-03 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-03, 2nd edition of 18 August 2025","categories":["petro"],"row_index":543,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid biofuel Transient moisture Range: (3,60 – 36,60) % Weight method SW/ZLGIG/PB-03 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-03, 2nd edition of 18 August 2025","search_zh":"固体燃料：固体生物燃料 SW/ZLGIG/PB-03 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-03, 2nd edition of 18 August 2025","test_object_zh":"固体燃料：固体生物燃料"},{"_id":"6a5a55ef9af9f73f38250cbc","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel","test_object_en":"Solid fuels: solid biofuel","methodology":"Zawartość wilgoci w próbce analitycznej Zakres: (0,60 – 10,61) % Metoda termograwimetryczna (TGA) Moisture content in analytical sample Range: (0,60 – 10,61) % Thermogravimetric method (TGA)","methodology_en":"Moisture content in analytical sample Range: (0,60 – 10,61) % Thermogravimetric method (TGA)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej Zakres: (0,60 – 10,61) % Metoda termograwimetryczna (TGA) Moisture content in analytical sample Range: (0,60 – 10,61) % Thermogravimetric method (TGA)","reference":"PN-EN ISO 18134-3:2023-12","norm_bases":["PN-EN ISO 18134-3:2023-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel Zawartość wilgoci w próbce analitycznej Zakres: (0,60 – 10,61) % Metoda termograwimetryczna (TGA) Moisture content in analytical sample Range: (0,60 – 10,61) % Thermogravimetric method (TGA) PN-EN ISO 18134-3:2023-12 Paliwa stale: biopaliwa stale Solid fuels: solid biofuel Zawartosc wilgoci w probce analitycznej Zakres: (0,60 – 10,61) % Metoda termograwimetryczna (TGA) Moisture content in analytical sample Range: (0,60 – 10,61) % Thermogravimetric method (TGA) PN-EN ISO 18134-3:2023-12","categories":["petro"],"row_index":544,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid biofuel Moisture content in analytical sample Range: (0,60 – 10,61) % Thermogravimetric method (TGA) PN-EN ISO 18134-3:2023-12","search_zh":"固体燃料：固体生物燃料 PN-EN ISO 18134-3:2023-12","test_object_zh":"固体燃料：固体生物燃料"},{"_id":"6a5a55ef9af9f73f38250cbd","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel","test_object_en":"Solid fuels: solid biofuel","methodology":"Zawartość wilgoci w próbce analitycznej Zakres: (0,50 – 10,30) % Metoda wagowa Moisture content in analytical sample Range: (0,50 – 10,30) % Weight method","methodology_en":"Moisture content in analytical sample Range: (0,50 – 10,30) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej Zakres: (0,50 – 10,30) % Metoda wagowa Moisture content in analytical sample Range: (0,50 – 10,30) % Weight method","reference":"PN-EN ISO 18134-3:2023-12","norm_bases":["PN-EN ISO 18134-3:2023-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel Zawartość wilgoci w próbce analitycznej Zakres: (0,50 – 10,30) % Metoda wagowa Moisture content in analytical sample Range: (0,50 – 10,30) % Weight method PN-EN ISO 18134-3:2023-12 Paliwa stale: biopaliwa stale Solid fuels: solid biofuel Zawartosc wilgoci w probce analitycznej Zakres: (0,50 – 10,30) % Metoda wagowa Moisture content in analytical sample Range: (0,50 – 10,30) % Weight method PN-EN ISO 18134-3:2023-12","categories":["petro"],"row_index":545,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid biofuel Moisture content in analytical sample Range: (0,50 – 10,30) % Weight method PN-EN ISO 18134-3:2023-12","search_zh":"固体燃料：固体生物燃料 PN-EN ISO 18134-3:2023-12","test_object_zh":"固体燃料：固体生物燃料"},{"_id":"6a5a55ef9af9f73f38250cbe","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel","test_object_en":"Solid fuels: solid biofuel","methodology":"Zawartość wilgoci całkowitej Zakres: (0,50 – 72,80) % Metoda wagowa Total moisture content Range: (0,50 – 72,80) % Weight method","methodology_en":"Total moisture content Range: (0,50 – 72,80) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej Zakres: (0,50 – 72,80) % Metoda wagowa Total moisture content Range: (0,50 – 72,80) % Weight method","reference":"PN-EN ISO 18134-2:2017-03","norm_bases":["PN-EN ISO 18134-2:2017-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel Zawartość wilgoci całkowitej Zakres: (0,50 – 72,80) % Metoda wagowa Total moisture content Range: (0,50 – 72,80) % Weight method PN-EN ISO 18134-2:2017-03 Paliwa stale: biopaliwa stale Solid fuels: solid biofuel Zawartosc wilgoci calkowitej Zakres: (0,50 – 72,80) % Metoda wagowa Total moisture content Range: (0,50 – 72,80) % Weight method PN-EN ISO 18134-2:2017-03","categories":["petro"],"row_index":546,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid biofuel Total moisture content Range: (0,50 – 72,80) % Weight method PN-EN ISO 18134-2:2017-03","search_zh":"固体燃料：固体生物燃料 PN-EN ISO 18134-2:2017-03","test_object_zh":"固体燃料：固体生物燃料"},{"_id":"6a5a55ef9af9f73f38250cbf","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel","test_object_en":"Solid fuels: solid biofuel","methodology":"Zawartość wilgoci całkowitej (z obliczeń) Total moisture content (from calculations)","methodology_en":"Total moisture content (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej (z obliczeń) Total moisture content (from calculations)","reference":"SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel Zawartość wilgoci całkowitej (z obliczeń) Total moisture content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025 Paliwa stale: biopaliwa stale Solid fuels: solid biofuel Zawartosc wilgoci calkowitej (z obliczen) Total moisture content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","categories":["petro"],"row_index":547,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid biofuel Total moisture content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","search_zh":"固体燃料：固体生物燃料 全水分含量（由计算得出） Total moisture content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","test_object_zh":"固体燃料：固体生物燃料","methodology_zh":"全水分含量（由计算得出） Total moisture content (from calculations)"},{"_id":"6a5a55ef9af9f73f38250cc0","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel","test_object_en":"Solid fuels: solid biofuel","methodology":"Zawartość popiołu Zakres: (0,15 – 34,50) % Metoda termograwimetryczna (TGA) Ash content Range: (0,15 – 34,50) % Thermogravimetric method (TGA)","methodology_en":"Ash content Range: (0,15 – 34,50) % Thermogravimetric method (TGA)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość popiołu Zakres: (0,15 – 34,50) % Metoda termograwimetryczna (TGA) Ash content Range: (0,15 – 34,50) % Thermogravimetric method (TGA)","reference":"PN-EN ISO 18122:2023-05","norm_bases":["PN-EN ISO 18122:2023-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel Zawartość popiołu Zakres: (0,15 – 34,50) % Metoda termograwimetryczna (TGA) Ash content Range: (0,15 – 34,50) % Thermogravimetric method (TGA) PN-EN ISO 18122:2023-05 Paliwa stale: biopaliwa stale Solid fuels: solid biofuel Zawartosc popiolu Zakres: (0,15 – 34,50) % Metoda termograwimetryczna (TGA) Ash content Range: (0,15 – 34,50) % Thermogravimetric method (TGA) PN-EN ISO 18122:2023-05","categories":["petro"],"row_index":548,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid biofuel Ash content Range: (0,15 – 34,50) % Thermogravimetric method (TGA) PN-EN ISO 18122:2023-05","search_zh":"固体燃料：固体生物燃料 PN-EN ISO 18122:2023-05","test_object_zh":"固体燃料：固体生物燃料"},{"_id":"6a5a55ef9af9f73f38250cc1","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel","test_object_en":"Solid fuels: solid biofuel","methodology":"Zawartość popiołu Zakres: (0,10 – 34,50) % Metoda wagowa (powolnego spopielania) Ash content Range: (0,10 – 34,50) % Weight method (slow burning)","methodology_en":"Ash content Range: (0,10 – 34,50) % Weight method (slow burning)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość popiołu Zakres: (0,10 – 34,50) % Metoda wagowa (powolnego spopielania) Ash content Range: (0,10 – 34,50) % Weight method (slow burning)","reference":"PN-EN ISO 18122:2023-05","norm_bases":["PN-EN ISO 18122:2023-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel Zawartość popiołu Zakres: (0,10 – 34,50) % Metoda wagowa (powolnego spopielania) Ash content Range: (0,10 – 34,50) % Weight method (slow burning) PN-EN ISO 18122:2023-05 Paliwa stale: biopaliwa stale Solid fuels: solid biofuel Zawartosc popiolu Zakres: (0,10 – 34,50) % Metoda wagowa (powolnego spopielania) Ash content Range: (0,10 – 34,50) % Weight method (slow burning) PN-EN ISO 18122:2023-05","categories":["petro"],"row_index":549,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid biofuel Ash content Range: (0,10 – 34,50) % Weight method (slow burning) PN-EN ISO 18122:2023-05","search_zh":"固体燃料：固体生物燃料 PN-EN ISO 18122:2023-05","test_object_zh":"固体燃料：固体生物燃料"},{"_id":"6a5a55ef9af9f73f38250cc2","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel","test_object_en":"Solid fuels: solid biofuel","methodology":"Zawartość węgla Zakres: (10,00 – 72,00) % Metoda wysokotemperaturowego spalania z detekcją IR Carbon content Range: (10,00 – 72,00) % High-temperature combustion method with IR detection","methodology_en":"Carbon content Range: (10,00 – 72,00) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość węgla Zakres: (10,00 – 72,00) % Metoda wysokotemperaturowego spalania z detekcją IR Carbon content Range: (10,00 – 72,00) % High-temperature combustion method with IR detection","reference":"PN-EN ISO 16948:2015-07","norm_bases":["PN-EN ISO 16948:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel Zawartość węgla Zakres: (10,00 – 72,00) % Metoda wysokotemperaturowego spalania z detekcją IR Carbon content Range: (10,00 – 72,00) % High-temperature combustion method with IR detection PN-EN ISO 16948:2015-07 Paliwa stale: biopaliwa stale Solid fuels: solid biofuel Zawartosc wegla Zakres: (10,00 – 72,00) % Metoda wysokotemperaturowego spalania z detekcja IR Carbon content Range: (10,00 – 72,00) % High-temperature combustion method with IR detection PN-EN ISO 16948:2015-07","categories":["petro"],"row_index":550,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid biofuel Carbon content Range: (10,00 – 72,00) % High-temperature combustion method with IR detection PN-EN ISO 16948:2015-07","search_zh":"固体燃料：固体生物燃料 PN-EN ISO 16948:2015-07","test_object_zh":"固体燃料：固体生物燃料"},{"_id":"6a5a55ef9af9f73f38250cc3","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel","test_object_en":"Solid fuels: solid biofuel","methodology":"Zawartość wodoru Zakres: (2,50 – 11,50) % Metoda wysokotemperaturowego spalania z detekcją IR Hydrogen content Range: (2,50 – 11,50) % High-temperature combustion method with IR detection","methodology_en":"Hydrogen content Range: (2,50 – 11,50) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wodoru Zakres: (2,50 – 11,50) % Metoda wysokotemperaturowego spalania z detekcją IR Hydrogen content Range: (2,50 – 11,50) % High-temperature combustion method with IR detection","reference":"PN-EN ISO 16948:2015-07","norm_bases":["PN-EN ISO 16948:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel Zawartość wodoru Zakres: (2,50 – 11,50) % Metoda wysokotemperaturowego spalania z detekcją IR Hydrogen content Range: (2,50 – 11,50) % High-temperature combustion method with IR detection PN-EN ISO 16948:2015-07 Paliwa stale: biopaliwa stale Solid fuels: solid biofuel Zawartosc wodoru Zakres: (2,50 – 11,50) % Metoda wysokotemperaturowego spalania z detekcja IR Hydrogen content Range: (2,50 – 11,50) % High-temperature combustion method with IR detection PN-EN ISO 16948:2015-07","categories":["petro"],"row_index":551,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid biofuel Hydrogen content Range: (2,50 – 11,50) % High-temperature combustion method with IR detection PN-EN ISO 16948:2015-07","search_zh":"固体燃料：固体生物燃料 PN-EN ISO 16948:2015-07","test_object_zh":"固体燃料：固体生物燃料"},{"_id":"6a5a55ef9af9f73f38250cc4","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel","test_object_en":"Solid fuels: solid biofuel","methodology":"Zawartość azotu Zakres: (0,01 – 5,60) % Metoda wysokotemperaturowego spalania z detekcją TC Nitrogen content Range: (0,01 – 5,60) % High-temperature combustion method with TC detection","methodology_en":"Nitrogen content Range: (0,01 – 5,60) % High-temperature combustion method with TC detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość azotu Zakres: (0,01 – 5,60) % Metoda wysokotemperaturowego spalania z detekcją TC Nitrogen content Range: (0,01 – 5,60) % High-temperature combustion method with TC detection","reference":"PN-EN ISO 16948:2015-07","norm_bases":["PN-EN ISO 16948:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel Zawartość azotu Zakres: (0,01 – 5,60) % Metoda wysokotemperaturowego spalania z detekcją TC Nitrogen content Range: (0,01 – 5,60) % High-temperature combustion method with TC detection PN-EN ISO 16948:2015-07 Paliwa stale: biopaliwa stale Solid fuels: solid biofuel Zawartosc azotu Zakres: (0,01 – 5,60) % Metoda wysokotemperaturowego spalania z detekcja TC Nitrogen content Range: (0,01 – 5,60) % High-temperature combustion method with TC detection PN-EN ISO 16948:2015-07","categories":["petro"],"row_index":552,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid biofuel Nitrogen content Range: (0,01 – 5,60) % High-temperature combustion method with TC detection PN-EN ISO 16948:2015-07","search_zh":"固体燃料：固体生物燃料 PN-EN ISO 16948:2015-07","test_object_zh":"固体燃料：固体生物燃料"},{"_id":"6a5a55ef9af9f73f38250cc5","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel","test_object_en":"Solid fuels: solid biofuel","methodology":"Zawartość tlenu (z obliczeń) Oxygen content (from calculations)","methodology_en":"Oxygen content (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość tlenu (z obliczeń) Oxygen content (from calculations)","reference":"SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel Zawartość tlenu (z obliczeń) Oxygen content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025 Paliwa stale: biopaliwa stale Solid fuels: solid biofuel Zawartosc tlenu (z obliczen) Oxygen content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","categories":["petro"],"row_index":553,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid biofuel Oxygen content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","search_zh":"固体燃料：固体生物燃料 氧含量（由计算得出） Oxygen content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","test_object_zh":"固体燃料：固体生物燃料","methodology_zh":"氧含量（由计算得出） Oxygen content (from calculations)"},{"_id":"6a5a55ef9af9f73f38250cc6","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel","test_object_en":"Solid fuels: solid biofuel","methodology":"Zawartość siarki całkowitej Zakres: (0,01 – 0,40) % Metoda wysokotemperaturowego spalania z detekcją IR Total sulfur content Range: (0,01 – 0,40)% High-temperature combustion method with IR detection","methodology_en":"Total sulfur content Range: (0,01 – 0,40)% High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej Zakres: (0,01 – 0,40) % Metoda wysokotemperaturowego spalania z detekcją IR Total sulfur content Range: (0,01 – 0,40)% High-temperature combustion method with IR detection","reference":"SW/ZLGIG/PB-10 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-10, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-10 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-10, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel Zawartość siarki całkowitej Zakres: (0,01 – 0,40) % Metoda wysokotemperaturowego spalania z detekcją IR Total sulfur content Range: (0,01 – 0,40)% High-temperature combustion method with IR detection SW/ZLGIG/PB-10 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-10, 2nd edition of 18 August 2025 Paliwa stale: biopaliwa stale Solid fuels: solid biofuel Zawartosc siarki calkowitej Zakres: (0,01 – 0,40) % Metoda wysokotemperaturowego spalania z detekcja IR Total sulfur content Range: (0,01 – 0,40)% High-temperature combustion method with IR detection SW/ZLGIG/PB-10 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-10, 2nd edition of 18 August 2025","categories":["petro"],"row_index":554,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid biofuel Total sulfur content Range: (0,01 – 0,40)% High-temperature combustion method with IR detection SW/ZLGIG/PB-10 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-10, 2nd edition of 18 August 2025","search_zh":"固体燃料：固体生物燃料 SW/ZLGIG/PB-10 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-10, 2nd edition of 18 August 2025","test_object_zh":"固体燃料：固体生物燃料"},{"_id":"6a5a55ef9af9f73f38250cc7","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel","test_object_en":"Solid fuels: solid biofuel","methodology":"Zawartość siarki popiołowej i palnej (z obliczeń) Ash sulphur and combustible sulfur content (from calculated)","methodology_en":"Ash sulphur and combustible sulfur content (from calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość siarki popiołowej i palnej (z obliczeń) Ash sulphur and combustible sulfur content (from calculated)","reference":"SW/ZLGIG/PB-10 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-10, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-10 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-10, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel Zawartość siarki popiołowej i palnej (z obliczeń) Ash sulphur and combustible sulfur content (from calculated) SW/ZLGIG/PB-10 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-10, 2nd edition of 18 August 2025 Paliwa stale: biopaliwa stale Solid fuels: solid biofuel Zawartosc siarki popiolowej i palnej (z obliczen) Ash sulphur and combustible sulfur content (from calculated) SW/ZLGIG/PB-10 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-10, 2nd edition of 18 August 2025","categories":["petro"],"row_index":555,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid biofuel Ash sulphur and combustible sulfur content (from calculated) SW/ZLGIG/PB-10 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-10, 2nd edition of 18 August 2025","search_zh":"固体燃料：固体生物燃料 SW/ZLGIG/PB-10 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-10, 2nd edition of 18 August 2025","test_object_zh":"固体燃料：固体生物燃料"},{"_id":"6a5a55ef9af9f73f38250cc8","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel","test_object_en":"Solid fuels: solid biofuel","methodology":"Zawartość części lotnych Zakres: (59,30 – 87,30) % Metoda wagowa Volatile matter content Range: (59,30 – 87,30) % Weight method","methodology_en":"Volatile matter content Range: (59,30 – 87,30) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość części lotnych Zakres: (59,30 – 87,30) % Metoda wagowa Volatile matter content Range: (59,30 – 87,30) % Weight method","reference":"PN-EN ISO 18123:2023-05","norm_bases":["PN-EN ISO 18123:2023-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel Zawartość części lotnych Zakres: (59,30 – 87,30) % Metoda wagowa Volatile matter content Range: (59,30 – 87,30) % Weight method PN-EN ISO 18123:2023-05 Paliwa stale: biopaliwa stale Solid fuels: solid biofuel Zawartosc czesci lotnych Zakres: (59,30 – 87,30) % Metoda wagowa Volatile matter content Range: (59,30 – 87,30) % Weight method PN-EN ISO 18123:2023-05","categories":["petro"],"row_index":556,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid biofuel Volatile matter content Range: (59,30 – 87,30) % Weight method PN-EN ISO 18123:2023-05","search_zh":"固体燃料：固体生物燃料 PN-EN ISO 18123:2023-05","test_object_zh":"固体燃料：固体生物燃料"},{"_id":"6a5a55ef9af9f73f38250cc9","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel","test_object_en":"Solid fuels: solid biofuel","methodology":"Ciepło spalania Zakres: (8055 – 37581) kJ/kg Metoda kalorymetryczna Gross calorific value Range: (8055 – 37581) kJ/kg Calorimetric method","methodology_en":"Gross calorific value Range: (8055 – 37581) kJ/kg Calorimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciepło spalania Zakres: (8055 – 37581) kJ/kg Metoda kalorymetryczna Gross calorific value Range: (8055 – 37581) kJ/kg Calorimetric method","reference":"PN-EN ISO 18125:2017-07","norm_bases":["PN-EN ISO 18125:2017-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel Ciepło spalania Zakres: (8055 – 37581) kJ/kg Metoda kalorymetryczna Gross calorific value Range: (8055 – 37581) kJ/kg Calorimetric method PN-EN ISO 18125:2017-07 Paliwa stale: biopaliwa stale Solid fuels: solid biofuel Cieplo spalania Zakres: (8055 – 37581) kJ/kg Metoda kalorymetryczna Gross calorific value Range: (8055 – 37581) kJ/kg Calorimetric method PN-EN ISO 18125:2017-07","categories":["petro"],"row_index":557,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid biofuel Gross calorific value Range: (8055 – 37581) kJ/kg Calorimetric method PN-EN ISO 18125:2017-07","search_zh":"固体燃料：固体生物燃料 PN-EN ISO 18125:2017-07","test_object_zh":"固体燃料：固体生物燃料"},{"_id":"6a5a55ef9af9f73f38250cca","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel","test_object_en":"Solid fuels: solid biofuel","methodology":"Wartość opałowa (z obliczeń) Net calorific value (from calculations)","methodology_en":"Net calorific value (calculated) Net calorific value (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wartość opałowa (z obliczeń) Net calorific value (from calculations)","reference":"PN-EN ISO 18125:2017-07","norm_bases":["PN-EN ISO 18125:2017-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel Wartość opałowa (z obliczeń) Net calorific value (from calculations) PN-EN ISO 18125:2017-07 Paliwa stale: biopaliwa stale Solid fuels: solid biofuel Wartosc opalowa (z obliczen) Net calorific value (from calculations) PN-EN ISO 18125:2017-07","categories":["petro"],"row_index":558,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid biofuel Net calorific value (calculated) Net calorific value (from calculations) PN-EN ISO 18125:2017-07","search_zh":"固体燃料：固体生物燃料 低位发热量（由计算得出） Net calorific value (from calculations) PN-EN ISO 18125:2017-07","test_object_zh":"固体燃料：固体生物燃料","methodology_zh":"低位发热量（由计算得出） Net calorific value (from calculations)"},{"_id":"6a5a55ef9af9f73f38250ccb","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel","test_object_en":"Solid fuels: solid biofuel","methodology":"Zawartość frakcji biodegradowalnej – udział masowy biomasy Zawartość frakcji nie biodegradowalnej – udział masowy niebiomasy Zakres: (61,50 – 99,50) % Metoda wagowa Biodegradable fraction content – mass fraction of biomass Non-biodegradable fraction content – mass fraction of non-biomass Range: (61.50 – 99.50) % Weight method","methodology_en":"Biodegradable fraction content – mass fraction of biomass Non-biodegradable fraction content – mass fraction of non-biomass Range: (61.50 – 99.50) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość frakcji biodegradowalnej – udział masowy biomasy Zawartość frakcji nie biodegradowalnej – udział masowy niebiomasy Zakres: (61,50 – 99,50) % Metoda wagowa Biodegradable fraction content – mass fraction of biomass Non-biodegradable fraction content – mass fraction of non-biomass Range: (61.50 – 99.50) % Weight method","reference":"SW/ZLGIG/PB-14 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-14, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-14 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-14, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel Zawartość frakcji biodegradowalnej – udział masowy biomasy Zawartość frakcji nie biodegradowalnej – udział masowy niebiomasy Zakres: (61,50 – 99,50) % Metoda wagowa Biodegradable fraction content – mass fraction of biomass Non-biodegradable fraction content – mass fraction of non-biomass Range: (61.50 – 99.50) % Weight method SW/ZLGIG/PB-14 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-14, 2nd edition of 18 August 2025 Paliwa stale: biopaliwa stale Solid fuels: solid biofuel Zawartosc frakcji biodegradowalnej – udzial masowy biomasy Zawartosc frakcji nie biodegradowalnej – udzial masowy niebiomasy Zakres: (61,50 – 99,50) % Metoda wagowa Biodegradable fraction content – mass fraction of biomass Non-biodegradable fraction content – mass fraction of non-biomass Range: (61.50 – 99.50) % Weight method SW/ZLGIG/PB-14 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-14, 2nd edition of 18 August 2025","categories":["petro"],"row_index":559,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid biofuel Biodegradable fraction content – mass fraction of biomass Non-biodegradable fraction content – mass fraction of non-biomass Range: (61.50 – 99.50) % Weight method SW/ZLGIG/PB-14 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-14, 2nd edition of 18 August 2025","search_zh":"固体燃料：固体生物燃料 SW/ZLGIG/PB-14 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-14, 2nd edition of 18 August 2025","test_object_zh":"固体燃料：固体生物燃料"},{"_id":"6a5a55ef9af9f73f38250ccc","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel","test_object_en":"Solid fuels: solid biofuel","methodology":"Zawartość chloru Zakres: (0,023 – 0,322) % Metoda miareczkowa Chlorine content Range: (0,023 – 0,322) % Titration method","methodology_en":"Chlorine content Range: (0,023 – 0,322) % Titration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość chloru Zakres: (0,023 – 0,322) % Metoda miareczkowa Chlorine content Range: (0,023 – 0,322) % Titration method","reference":"SW/ZLGIG/PB-13 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-13, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-13 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-13, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel Zawartość chloru Zakres: (0,023 – 0,322) % Metoda miareczkowa Chlorine content Range: (0,023 – 0,322) % Titration method SW/ZLGIG/PB-13 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-13, 2nd edition of 18 August 2025 Paliwa stale: biopaliwa stale Solid fuels: solid biofuel Zawartosc chloru Zakres: (0,023 – 0,322) % Metoda miareczkowa Chlorine content Range: (0,023 – 0,322) % Titration method SW/ZLGIG/PB-13 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-13, 2nd edition of 18 August 2025","categories":["petro"],"row_index":560,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid biofuel Chlorine content Range: (0,023 – 0,322) % Titration method SW/ZLGIG/PB-13 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-13, 2nd edition of 18 August 2025","search_zh":"固体燃料：固体生物燃料 SW/ZLGIG/PB-13 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-13, 2nd edition of 18 August 2025","test_object_zh":"固体燃料：固体生物燃料"},{"_id":"6a5a55ef9af9f73f38250ccd","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel","test_object_en":"Solid fuels: solid biofuel","methodology":"Zawartość chloru Zakres: (0,005 – 0,370) % Metoda wysokotemperaturowego spalania z detekcją kulometryczną Chlorine content Range: (0,005 – 0,370) % High-temperature combustion method with coulometric detection","methodology_en":"Chlorine content Range: (0,005 – 0,370) % High-temperature combustion method with coulometric detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość chloru Zakres: (0,005 – 0,370) % Metoda wysokotemperaturowego spalania z detekcją kulometryczną Chlorine content Range: (0,005 – 0,370) % High-temperature combustion method with coulometric detection","reference":"SW/ZLGIG/PB-12 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-12, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-12 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-12, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biopaliwa stałe Solid fuels: solid biofuel Zawartość chloru Zakres: (0,005 – 0,370) % Metoda wysokotemperaturowego spalania z detekcją kulometryczną Chlorine content Range: (0,005 – 0,370) % High-temperature combustion method with coulometric detection SW/ZLGIG/PB-12 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-12, 2nd edition of 18 August 2025 Paliwa stale: biopaliwa stale Solid fuels: solid biofuel Zawartosc chloru Zakres: (0,005 – 0,370) % Metoda wysokotemperaturowego spalania z detekcja kulometryczna Chlorine content Range: (0,005 – 0,370) % High-temperature combustion method with coulometric detection SW/ZLGIG/PB-12 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-12, 2nd edition of 18 August 2025","categories":["petro"],"row_index":561,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid biofuel Chlorine content Range: (0,005 – 0,370) % High-temperature combustion method with coulometric detection SW/ZLGIG/PB-12 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-12, 2nd edition of 18 August 2025","search_zh":"固体燃料：固体生物燃料 SW/ZLGIG/PB-12 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-12, 2nd edition of 18 August 2025","test_object_zh":"固体燃料：固体生物燃料"},{"_id":"6a5a55ef9af9f73f38250cce","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 żużel, popiół, mieszanka popiołowo-żużlowa Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture","test_object_en":"Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture","methodology":"Zawartość wilgoci przemijającej Zakres: (0,01 – 44,00) % Metoda wagowa Transient moisture Range: (0,01 – 44,00) % Weight method","methodology_en":"Transient moisture Range: (0,01 – 44,00) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci przemijającej Zakres: (0,01 – 44,00) % Metoda wagowa Transient moisture Range: (0,01 – 44,00) % Weight method","reference":"SW/ZLGIG/PB-03 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-03, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-03 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-03, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 żużel, popiół, mieszanka popiołowo-żużlowa Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture Zawartość wilgoci przemijającej Zakres: (0,01 – 44,00) % Metoda wagowa Transient moisture Range: (0,01 – 44,00) % Weight method SW/ZLGIG/PB-03 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-03, 2nd edition of 18 August 2025 Odpady O): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 zuzel, popiol, mieszanka popiolowo-zuzlowa Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture Zawartosc wilgoci przemijajacej Zakres: (0,01 – 44,00) % Metoda wagowa Transient moisture Range: (0,01 – 44,00) % Weight method SW/ZLGIG/PB-03 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-03, 2nd edition of 18 August 2025","categories":["environment"],"row_index":562,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture Transient moisture Range: (0,01 – 44,00) % Weight method SW/ZLGIG/PB-03 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-03, 2nd edition of 18 August 2025","search_zh":"废物 O)：代码 10 01 01、10 01 02、10 01 15、10 01 17、10 01 80、10 01 82 炉渣、灰、灰渣混合料 Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture SW/ZLGIG/PB-03 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-03, 2nd edition of 18 August 2025","test_object_zh":"废物 O)：代码 10 01 01、10 01 02、10 01 15、10 01 17、10 01 80、10 01 82 炉渣、灰、灰渣混合料 Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture"},{"_id":"6a5a55ef9af9f73f38250ccf","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 żużel, popiół, mieszanka popiołowo-żużlowa Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture","test_object_en":"Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture","methodology":"Zawartość wilgoci w próbce analitycznej Zakres: (0,05 – 5,60) % Metoda termograwimetryczna (TGA) Moisture content in analytical sample Range: (0,05 – 5,60) % Thermogravimetric method (TGA)","methodology_en":"Moisture content in analytical sample Range: (0,05 – 5,60) % Thermogravimetric method (TGA)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej Zakres: (0,05 – 5,60) % Metoda termograwimetryczna (TGA) Moisture content in analytical sample Range: (0,05 – 5,60) % Thermogravimetric method (TGA)","reference":"SW/ZLGIG/PB-04 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-04, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-04 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-04, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 żużel, popiół, mieszanka popiołowo-żużlowa Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture Zawartość wilgoci w próbce analitycznej Zakres: (0,05 – 5,60) % Metoda termograwimetryczna (TGA) Moisture content in analytical sample Range: (0,05 – 5,60) % Thermogravimetric method (TGA) SW/ZLGIG/PB-04 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-04, 2nd edition of 18 August 2025 Odpady O): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 zuzel, popiol, mieszanka popiolowo-zuzlowa Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture Zawartosc wilgoci w probce analitycznej Zakres: (0,05 – 5,60) % Metoda termograwimetryczna (TGA) Moisture content in analytical sample Range: (0,05 – 5,60) % Thermogravimetric method (TGA) SW/ZLGIG/PB-04 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-04, 2nd edition of 18 August 2025","categories":["environment"],"row_index":563,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture Moisture content in analytical sample Range: (0,05 – 5,60) % Thermogravimetric method (TGA) SW/ZLGIG/PB-04 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-04, 2nd edition of 18 August 2025","search_zh":"废物 O)：代码 10 01 01、10 01 02、10 01 15、10 01 17、10 01 80、10 01 82 炉渣、灰、灰渣混合料 Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture SW/ZLGIG/PB-04 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-04, 2nd edition of 18 August 2025","test_object_zh":"废物 O)：代码 10 01 01、10 01 02、10 01 15、10 01 17、10 01 80、10 01 82 炉渣、灰、灰渣混合料 Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture"},{"_id":"6a5a55ef9af9f73f38250cd0","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 żużel, popiół, mieszanka popiołowo-żużlowa Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture","test_object_en":"Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture","methodology":"Zawartość wilgoci w próbce analitycznej Zakres: (0,05 – 5,80) % Metoda wagowa Moisture content in analytical sample Range: (0,05 – 5,80) % Weight method","methodology_en":"Moisture content in analytical sample Range: (0,05 – 5,80) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej Zakres: (0,05 – 5,80) % Metoda wagowa Moisture content in analytical sample Range: (0,05 – 5,80) % Weight method","reference":"SW/ZLGIG/PB-05 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-05, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-05 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-05, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 żużel, popiół, mieszanka popiołowo-żużlowa Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture Zawartość wilgoci w próbce analitycznej Zakres: (0,05 – 5,80) % Metoda wagowa Moisture content in analytical sample Range: (0,05 – 5,80) % Weight method SW/ZLGIG/PB-05 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-05, 2nd edition of 18 August 2025 Odpady O): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 zuzel, popiol, mieszanka popiolowo-zuzlowa Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture Zawartosc wilgoci w probce analitycznej Zakres: (0,05 – 5,80) % Metoda wagowa Moisture content in analytical sample Range: (0,05 – 5,80) % Weight method SW/ZLGIG/PB-05 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-05, 2nd edition of 18 August 2025","categories":["environment"],"row_index":564,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture Moisture content in analytical sample Range: (0,05 – 5,80) % Weight method SW/ZLGIG/PB-05 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-05, 2nd edition of 18 August 2025","search_zh":"废物 O)：代码 10 01 01、10 01 02、10 01 15、10 01 17、10 01 80、10 01 82 炉渣、灰、灰渣混合料 Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture SW/ZLGIG/PB-05 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-05, 2nd edition of 18 August 2025","test_object_zh":"废物 O)：代码 10 01 01、10 01 02、10 01 15、10 01 17、10 01 80、10 01 82 炉渣、灰、灰渣混合料 Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture"},{"_id":"6a5a55ef9af9f73f38250cd1","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 żużel, popiół, mieszanka popiołowo-żużlowa Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture","test_object_en":"Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture","methodology":"Zawartość wilgoci całkowitej (z obliczeń) Total moisture content (from calculations)","methodology_en":"Total moisture content (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej (z obliczeń) Total moisture content (from calculations)","reference":"SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 żużel, popiół, mieszanka popiołowo-żużlowa Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture Zawartość wilgoci całkowitej (z obliczeń) Total moisture content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025 Odpady O): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 zuzel, popiol, mieszanka popiolowo-zuzlowa Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture Zawartosc wilgoci calkowitej (z obliczen) Total moisture content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","categories":["environment"],"row_index":565,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture Total moisture content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","search_zh":"废物 O)：代码 10 01 01、10 01 02、10 01 15、10 01 17、10 01 80、10 01 82 炉渣、灰、灰渣混合料 Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture 全水分含量（由计算得出） Total moisture content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","test_object_zh":"废物 O)：代码 10 01 01、10 01 02、10 01 15、10 01 17、10 01 80、10 01 82 炉渣、灰、灰渣混合料 Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture","methodology_zh":"全水分含量（由计算得出） Total moisture content (from calculations)"},{"_id":"6a5a55ef9af9f73f38250cd2","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 żużel, popiół, mieszanka popiołowo-żużlowa Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture","test_object_en":"Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture","methodology":"Zawartość popiołu Zakres: (31,60 – 100,00) % Metoda termograwimetryczna (TGA) Ash content Range: (31,60 – 100,00) % Thermogravimetric method (TGA)","methodology_en":"Ash content Range: (31,60 – 100,00) % Thermogravimetric method (TGA)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość popiołu Zakres: (31,60 – 100,00) % Metoda termograwimetryczna (TGA) Ash content Range: (31,60 – 100,00) % Thermogravimetric method (TGA)","reference":"SW/ZLGIG/PB-07 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-07, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-07 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-07, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 żużel, popiół, mieszanka popiołowo-żużlowa Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture Zawartość popiołu Zakres: (31,60 – 100,00) % Metoda termograwimetryczna (TGA) Ash content Range: (31,60 – 100,00) % Thermogravimetric method (TGA) SW/ZLGIG/PB-07 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-07, 2nd edition of 18 August 2025 Odpady O): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 zuzel, popiol, mieszanka popiolowo-zuzlowa Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture Zawartosc popiolu Zakres: (31,60 – 100,00) % Metoda termograwimetryczna (TGA) Ash content Range: (31,60 – 100,00) % Thermogravimetric method (TGA) SW/ZLGIG/PB-07 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-07, 2nd edition of 18 August 2025","categories":["environment"],"row_index":566,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture Ash content Range: (31,60 – 100,00) % Thermogravimetric method (TGA) SW/ZLGIG/PB-07 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-07, 2nd edition of 18 August 2025","search_zh":"废物 O)：代码 10 01 01、10 01 02、10 01 15、10 01 17、10 01 80、10 01 82 炉渣、灰、灰渣混合料 Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture SW/ZLGIG/PB-07 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-07, 2nd edition of 18 August 2025","test_object_zh":"废物 O)：代码 10 01 01、10 01 02、10 01 15、10 01 17、10 01 80、10 01 82 炉渣、灰、灰渣混合料 Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture"},{"_id":"6a5a55ef9af9f73f38250cd3","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 żużel, popiół, mieszanka popiołowo-żużlowa Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture","test_object_en":"Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture","methodology":"Zawartość popiołu Zakres: (31,50 – 100,00) % Metoda wagowa Ash content Range: (31,50 – 100,00) % Weight method","methodology_en":"Ash content Range: (31,50 – 100,00) % Weight method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość popiołu Zakres: (31,50 – 100,00) % Metoda wagowa Ash content Range: (31,50 – 100,00) % Weight method","reference":"SW/ZLGIG/PB-06 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-06, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-06 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-06, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 żużel, popiół, mieszanka popiołowo-żużlowa Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture Zawartość popiołu Zakres: (31,50 – 100,00) % Metoda wagowa Ash content Range: (31,50 – 100,00) % Weight method SW/ZLGIG/PB-06 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-06, 2nd edition of 18 August 2025 Odpady O): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 zuzel, popiol, mieszanka popiolowo-zuzlowa Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture Zawartosc popiolu Zakres: (31,50 – 100,00) % Metoda wagowa Ash content Range: (31,50 – 100,00) % Weight method SW/ZLGIG/PB-06 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-06, 2nd edition of 18 August 2025","categories":["environment"],"row_index":567,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture Ash content Range: (31,50 – 100,00) % Weight method SW/ZLGIG/PB-06 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-06, 2nd edition of 18 August 2025","search_zh":"废物 O)：代码 10 01 01、10 01 02、10 01 15、10 01 17、10 01 80、10 01 82 炉渣、灰、灰渣混合料 Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture SW/ZLGIG/PB-06 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-06, 2nd edition of 18 August 2025","test_object_zh":"废物 O)：代码 10 01 01、10 01 02、10 01 15、10 01 17、10 01 80、10 01 82 炉渣、灰、灰渣混合料 Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture"},{"_id":"6a5a55ef9af9f73f38250cd4","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 żużel, popiół, mieszanka popiołowo-żużlowa Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture","test_object_en":"Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture","methodology":"Zawartość części palnych (z obliczeń) Combustible parts content (from calculations)","methodology_en":"Combustible parts content (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość części palnych (z obliczeń) Combustible parts content (from calculations)","reference":"SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 żużel, popiół, mieszanka popiołowo-żużlowa Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture Zawartość części palnych (z obliczeń) Combustible parts content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025 Odpady O): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 zuzel, popiol, mieszanka popiolowo-zuzlowa Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture Zawartosc czesci palnych (z obliczen) Combustible parts content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","categories":["environment"],"row_index":568,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture Combustible parts content (from calculations) SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","search_zh":"废物 O)：代码 10 01 01、10 01 02、10 01 15、10 01 17、10 01 80、10 01 82 炉渣、灰、灰渣混合料 Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture SW/ZLGIG/PB-16 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-16, 2nd edition of 18 August 2025","test_object_zh":"废物 O)：代码 10 01 01、10 01 02、10 01 15、10 01 17、10 01 80、10 01 82 炉渣、灰、灰渣混合料 Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture"},{"_id":"6a5a55ef9af9f73f38250cd5","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Odpady O): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 żużel, popiół, mieszanka popiołowo-żużlowa Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture","test_object_en":"Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture","methodology":"Zawartość węgla Zakres: (2,00 – 44,00) % Metoda wysokotemperaturowego spalania z detekcją IR Carbon content Range: (2,00 – 44,00) % High-temperature combustion method with IR detection","methodology_en":"Carbon content Range: (2,00 – 44,00) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość węgla Zakres: (2,00 – 44,00) % Metoda wysokotemperaturowego spalania z detekcją IR Carbon content Range: (2,00 – 44,00) % High-temperature combustion method with IR detection","reference":"SW/ZLGIG/PB-11 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-11, 2nd edition of 18 August 2025","norm_bases":["SW/ZLGIG/PB-11 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-11, 2nd edition of 18 August 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 żużel, popiół, mieszanka popiołowo-żużlowa Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture Zawartość węgla Zakres: (2,00 – 44,00) % Metoda wysokotemperaturowego spalania z detekcją IR Carbon content Range: (2,00 – 44,00) % High-temperature combustion method with IR detection SW/ZLGIG/PB-11 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-11, 2nd edition of 18 August 2025 Odpady O): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 zuzel, popiol, mieszanka popiolowo-zuzlowa Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture Zawartosc wegla Zakres: (2,00 – 44,00) % Metoda wysokotemperaturowego spalania z detekcja IR Carbon content Range: (2,00 – 44,00) % High-temperature combustion method with IR detection SW/ZLGIG/PB-11 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-11, 2nd edition of 18 August 2025","categories":["environment"],"row_index":569,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture Carbon content Range: (2,00 – 44,00) % High-temperature combustion method with IR detection SW/ZLGIG/PB-11 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-11, 2nd edition of 18 August 2025","search_zh":"废物 O)：代码 10 01 01、10 01 02、10 01 15、10 01 17、10 01 80、10 01 82 炉渣、灰、灰渣混合料 Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture SW/ZLGIG/PB-11 edycja 2 z dnia 18.08.2025 r. SW/ZLGIG/PB-11, 2nd edition of 18 August 2025","test_object_zh":"废物 O)：代码 10 01 01、10 01 02、10 01 15、10 01 17、10 01 80、10 01 82 炉渣、灰、灰渣混合料 Wastes O): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, 10 01 82 slag, ash, ash-slag mixture"},{"_id":"6a5a55ef9af9f73f38250cd6","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Mechaniczne i automatyczne urządzenia do pobierania próbek węgla kamiennego Mechanical and automatical sampling systems for hard coal","test_object_en":"Mechanical and automatical sampling systems for hard coal","methodology":"Dokładność, precyzja pobierania, przygotowania i analizy próbek Accuracy and precision of sampling, preparation and analysis samples","methodology_en":"Accuracy and precision of sampling, preparation and analysis samples","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Dokładność, precyzja pobierania, przygotowania i analizy próbek Accuracy and precision of sampling, preparation and analysis samples","reference":"PN-G-04502:2014-11 pkt. 10","norm_bases":["PN-G-04502:2014-11 pkt. 10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mechaniczne i automatyczne urządzenia do pobierania próbek węgla kamiennego Mechanical and automatical sampling systems for hard coal Dokładność, precyzja pobierania, przygotowania i analizy próbek Accuracy and precision of sampling, preparation and analysis samples PN-G-04502:2014-11 pkt. 10 Mechaniczne i automatyczne urzadzenia do pobierania probek wegla kamiennego Mechanical and automatical sampling systems for hard coal Dokladnosc, precyzja pobierania, przygotowania i analizy probek Accuracy and precision of sampling, preparation and analysis samples PN-G-04502:2014-11 pkt. 10","categories":["other"],"row_index":570,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Mechanical and automatical sampling systems for hard coal Accuracy and precision of sampling, preparation and analysis samples PN-G-04502:2014-11 pkt. 10"},{"_id":"6a5a55ef9af9f73f38250cd7","lab_id":"69ad52a3de79e566650fb0b9","country":"PL","accr_number":"AB 005","accr_body":"PCA","test_object":"Paliwa stałe E Solid fuels E","test_object_en":"Solid fuels E","methodology":"Zawartość rtęci Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji Mercury content Atomic absorption spectrometry method with amalgamation technique","methodology_en":"Mercury content Atomic absorption spectrometry method with amalgamation technique","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość rtęci Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji Mercury content Atomic absorption spectrometry method with amalgamation technique","reference":"SW/ZLGIG/PB-15","norm_bases":["SW/ZLGIG/PB-15"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe E Solid fuels E Zawartość rtęci Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji Mercury content Atomic absorption spectrometry method with amalgamation technique SW/ZLGIG/PB-15 Paliwa stale E Solid fuels E Zawartosc rteci Metoda absorpcyjnej spektrometrii atomowej z technika amalgamacji Mercury content Atomic absorption spectrometry method with amalgamation technique SW/ZLGIG/PB-15","categories":["petro"],"row_index":571,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels E Mercury content Atomic absorption spectrometry method with amalgamation technique SW/ZLGIG/PB-15"}],"has_pdf":true}