{"lab":{"_id":"6af252d10ecd48de0c70590e","country":"CZ","accr_number":"8341","accr_body":"ČIA","address":"Lípy 15, 293 06 Kosmonosy","categories":["other"],"city":"Kosmonosy","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"medical","location":{"type":"Point","coordinates":[14.9258193,50.4422927]},"map_coord":[50.4422927,14.9258193],"map_geo":"cai-mapa","methods_count":5,"name":"Psychiatrická nemocnice Kosmonosy","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Badania laboratoryjne w specjalności biochemia kliniczna, w zakresie określonym w załączniku do świadectwa.","search_text":"psychiatrická nemocnice kosmonosy lípy 15, 293 06 kosmonosy 8341","source_page_url":"https://www.cai.cz/?subjekt=8341-psychiatricka-nemocnice-kosmonosy","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"15-04-2029","website":"www.pnkosmonosy.cz","certificate_date":"15.04.2026","certificate_no":"185/2026","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Badania laboratoryjne w specjalności biochemia kliniczna, w zakresie określonym w załączniku do świadectwa.","en":"Laboratory examinations in the specialty of clinical biochemistry, as specified in the annex to this certificate.","zh":"临床生物化学专业的实验室检验，具体范围见本证书附件。","cs":"Laboratorní vyšetření v odbornosti klinická biochemie, vymezené přílohou tohoto osvědčení.","de":"Laboruntersuchungen im Fachgebiet klinische Biochemie, im Umfang gemäß Anlage zur Akkreditierungsurkunde."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Oddział Biochemii Klinicznej, Hematologii i Toksykologii","lab_division_cs":"Oddělení klinické biochemie, hematologie a toxikologie","lab_division_en":"Department of Clinical Biochemistry, Haematology and Toxicology","lab_division_zh":"临床生物化学、血液学和毒理学科","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[{"pl":"Laboratorium nie stosuje elastycznego podejścia do zakresu akredytacji.","en":"The laboratory does not apply a flexible approach to the scope of accreditation.","zh":"实验室不采用灵活认可范围方式。","cs":"Laboratoř neuplatňuje flexibilní přístup k rozsahu akreditace."}],"source_lang":"cs","source_pdf_sha256":"2ef1c8d95fb590d1d22eb8d26730705ecf1ecf625ea02ad8b7312de893051bfe","source_pdf_url":"https://www.cai.cz/OA/pdf/185_2026_CS.pdf","source_pdf_url_en":null,"has_de":true,"lab_division_de":"Abteilung für klinische Biochemie, Hämatologie und Toxikologie"},"methods":[{"_id":"102d3d48b9f9860bdc7aac55","lab_id":"6af252d10ecd48de0c70590e","country":"CZ","accr_number":"8341","accr_body":"ČIA","row_label":"1","test_object":"Surowica","test_object_en":"Serum","test_object_zh":"血清","test_object_cs":"Sérum","methodology":"Glukoza","methodology_en":"Glucose","methodology_zh":"葡萄糖","methodology_cs":"Glukóza","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Spektrofotometria absorpcyjna","technique_en":"Absorption spectrophotometry","technique_zh":"吸收分光光度法","technique_cs":"Absorpční spektrofotometrie","techniques":["Spektrofotometria absorpcyjna"],"techniques_en":["Absorption spectrophotometry"],"techniques_zh":["吸收分光光度法"],"techniques_cs":["Absorpční spektrofotometrie"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Glukoza\nSpektrofotometria absorpcyjna","reference":"RD02SOP005GLU, vydání č. 5; AU480","norm_bases":["RD02SOP005GLU"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"801 - Biochemia kliniczna","regulatory_area_en":"801 - Clinical Biochemistry","regulatory_area_zh":"801 - 临床生物化学","regulatory_area_cs":"801 - Klinická biochemie","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Surowica Glukoza Spektrofotometria absorpcyjna Sérum Glukóza Absorpční spektrofotometrie RD02SOP005GLU, vydání č. 5; AU480 Surowica Glukoza Spektrofotometria absorpcyjna Serum Glukoza Absorpcni spektrofotometrie RD02SOP005GLU, vydani c. 5; AU480","search_en":"Serum Glucose Absorption spectrophotometry 801 - Clinical Biochemistry Absorption spectrophotometry RD02SOP005GLU, issue No. 5; AU480","search_zh":"血清 葡萄糖 吸收分光光度法 801 - 临床生物化学 吸收分光光度法 RD02SOP005GLU, 第5版; AU480","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","reference_pl":"RD02SOP005GLU, wydanie nr 5; AU480","reference_en":"RD02SOP005GLU, issue No. 5; AU480","methodology_de":"Glucose","reference_de":"RD02SOP005GLU, Ausgabe Nr. 5; AU480","regulatory_area_de":"801 - Klinische Biochemie","search_de":"Serum Glucose Absorptionsspektrophotometrie 801 - Klinische Biochemie Absorptionsspektrophotometrie RD02SOP005GLU, Ausgabe Nr. 5; AU480","technique_de":"Absorptionsspektrophotometrie","techniques_de":["Absorptionsspektrophotometrie"],"test_object_de":"Serum","reference_zh":"RD02SOP005GLU, 第5版; AU480"},{"_id":"291eb0777a01b7f91450837c","lab_id":"6af252d10ecd48de0c70590e","country":"CZ","accr_number":"8341","accr_body":"ČIA","row_label":"2","test_object":"Surowica","test_object_en":"Serum","test_object_zh":"血清","test_object_cs":"Sérum","methodology":"Składniki mineralne","methodology_en":"Minerals","methodology_zh":"矿物质","methodology_cs":"Minerály","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Potencjometria","technique_en":"Potentiometry","technique_zh":"电位法","technique_cs":"Potenciometrie","techniques":["Potencjometria"],"techniques_en":["Potentiometry"],"techniques_zh":["电位法"],"techniques_cs":["Potenciometrie"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Składniki mineralne\nPotencjometria","reference":"RD02SOP011Na, vydání č. 5; RD02SOP012K, vydání č. 5; AU480","norm_bases":["RD02SOP011Na","RD02SOP012K"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"801 - Biochemia kliniczna","regulatory_area_en":"801 - Clinical Biochemistry","regulatory_area_zh":"801 - 临床生物化学","regulatory_area_cs":"801 - Klinická biochemie","flexible":false,"flexibility":null,"outside_premises":false,"note":"Na⁺, K⁺","note_en":"Na⁺, K⁺","note_zh":"钠离子（Na⁺）、钾离子（K⁺）","note_cs":"Na⁺, K⁺","search_text":"Surowica Składniki mineralne Potencjometria Sérum Minerály Potenciometrie RD02SOP011Na, vydání č. 5; RD02SOP012K, vydání č. 5; AU480 Surowica Skladniki mineralne Potencjometria Serum Mineraly Potenciometrie RD02SOP011Na, vydani c. 5; RD02SOP012K, vydani c. 5; AU480","search_en":"Serum Minerals Potentiometry 801 - Clinical Biochemistry Potentiometry RD02SOP011Na, issue No. 5; RD02SOP012K, issue No. 5; AU480","search_zh":"血清 矿物质 电位法 801 - 临床生物化学 电位法 RD02SOP011Na, 第5版; RD02SOP012K, 第5版; AU480","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","reference_pl":"RD02SOP011Na, wydanie nr 5; RD02SOP012K, wydanie nr 5; AU480","reference_en":"RD02SOP011Na, issue No. 5; RD02SOP012K, issue No. 5; AU480","methodology_de":"Mineralische Bestandteile","reference_de":"RD02SOP011Na, Ausgabe Nr. 5; RD02SOP012K, Ausgabe Nr. 5; AU480","regulatory_area_de":"801 - Klinische Biochemie","search_de":"Serum Mineralische Bestandteile Potentiometrie 801 - Klinische Biochemie Potentiometrie RD02SOP011Na, Ausgabe Nr. 5; RD02SOP012K, Ausgabe Nr. 5; AU480","technique_de":"Potentiometrie","techniques_de":["Potentiometrie"],"test_object_de":"Serum","reference_zh":"RD02SOP011Na, 第5版; RD02SOP012K, 第5版; AU480"},{"_id":"ff482ac791b2a1639d820fe4","lab_id":"6af252d10ecd48de0c70590e","country":"CZ","accr_number":"8341","accr_body":"ČIA","row_label":"3","test_object":"Surowica","test_object_en":"Serum","test_object_zh":"血清","test_object_cs":"Sérum","methodology":"Białka","methodology_en":"Proteins","methodology_zh":"蛋白质","methodology_cs":"Proteiny","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Spektrofotometria absorpcyjna","technique_en":"Absorption spectrophotometry","technique_zh":"吸收分光光度法","technique_cs":"Absorpční spektrofotometrie","techniques":["Spektrofotometria absorpcyjna"],"techniques_en":["Absorption spectrophotometry"],"techniques_zh":["吸收分光光度法"],"techniques_cs":["Absorpční spektrofotometrie"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Białka\nSpektrofotometria absorpcyjna","reference":"RD02SOP067CB, vydání č. 5; RD02SOP068ALB, vydání č. 5; AU480","norm_bases":["RD02SOP067CB","RD02SOP068ALB"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"801 - Biochemia kliniczna","regulatory_area_en":"801 - Clinical Biochemistry","regulatory_area_zh":"801 - 临床生物化学","regulatory_area_cs":"801 - Klinická biochemie","flexible":false,"flexibility":null,"outside_premises":false,"note":"Białko całkowite, albumina","note_en":"Total protein, Albumin","note_zh":"总蛋白、白蛋白","note_cs":"Celková bílkovina, Albumin","search_text":"Surowica Białka Spektrofotometria absorpcyjna Sérum Proteiny Absorpční spektrofotometrie RD02SOP067CB, vydání č. 5; RD02SOP068ALB, vydání č. 5; AU480 Surowica Bialka Spektrofotometria absorpcyjna Serum Proteiny Absorpcni spektrofotometrie RD02SOP067CB, vydani c. 5; RD02SOP068ALB, vydani c. 5; AU480","search_en":"Serum Proteins Absorption spectrophotometry 801 - Clinical Biochemistry Absorption spectrophotometry RD02SOP067CB, issue No. 5; RD02SOP068ALB, issue No. 5; AU480","search_zh":"血清 蛋白质 吸收分光光度法 801 - 临床生物化学 吸收分光光度法 RD02SOP067CB, 第5版; RD02SOP068ALB, 第5版; AU480","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","reference_pl":"RD02SOP067CB, wydanie nr 5; RD02SOP068ALB, wydanie nr 5; AU480","reference_en":"RD02SOP067CB, issue No. 5; RD02SOP068ALB, issue No. 5; AU480","methodology_de":"Proteine","reference_de":"RD02SOP067CB, Ausgabe Nr. 5; RD02SOP068ALB, Ausgabe Nr. 5; AU480","regulatory_area_de":"801 - Klinische Biochemie","search_de":"Serum Proteine Absorptionsspektrophotometrie 801 - Klinische Biochemie Absorptionsspektrophotometrie RD02SOP067CB, Ausgabe Nr. 5; RD02SOP068ALB, Ausgabe Nr. 5; AU480","technique_de":"Absorptionsspektrophotometrie","techniques_de":["Absorptionsspektrophotometrie"],"test_object_de":"Serum","reference_zh":"RD02SOP067CB, 第5版; RD02SOP068ALB, 第5版; AU480"},{"_id":"9cf3ca58da6f1fae2ad6410e","lab_id":"6af252d10ecd48de0c70590e","country":"CZ","accr_number":"8341","accr_body":"ČIA","row_label":"4","test_object":"Surowica","test_object_en":"Serum","test_object_zh":"血清","test_object_cs":"Sérum","methodology":"Enzymy","methodology_en":"Enzymes","methodology_zh":"酶","methodology_cs":"Enzymy","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Spektrofotometria absorpcyjna","technique_en":"Absorption spectrophotometry","technique_zh":"吸收分光光度法","technique_cs":"Absorpční spektrofotometrie","techniques":["Spektrofotometria absorpcyjna"],"techniques_en":["Absorption spectrophotometry"],"techniques_zh":["吸收分光光度法"],"techniques_cs":["Absorpční spektrofotometrie"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Enzymy\nSpektrofotometria absorpcyjna","reference":"RD02SOP041AST, vydání č. 5; RD02SOP042GGT, vydání č. 5; AU480","norm_bases":["RD02SOP041AST","RD02SOP042GGT"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"801 - Biochemia kliniczna","regulatory_area_en":"801 - Clinical Biochemistry","regulatory_area_zh":"801 - 临床生物化学","regulatory_area_cs":"801 - Klinická biochemie","flexible":false,"flexibility":null,"outside_premises":false,"note":"Aminotransferaza asparaginianowa (AST), gamma-glutamylotransferaza (GGT)","note_en":"Aspartate aminotransferase (AST), Gamma-glutamyltransferase (GGT)","note_zh":"天门冬氨酸氨基转移酶（AST）、γ-谷氨酰转移酶（GGT）","note_cs":"Aspartátaminotransferáza (AST), Gamaglutamyltransferáza (GGT)","search_text":"Surowica Enzymy Spektrofotometria absorpcyjna Sérum Enzymy Absorpční spektrofotometrie RD02SOP041AST, vydání č. 5; RD02SOP042GGT, vydání č. 5; AU480 Surowica Enzymy Spektrofotometria absorpcyjna Serum Enzymy Absorpcni spektrofotometrie RD02SOP041AST, vydani c. 5; RD02SOP042GGT, vydani c. 5; AU480","search_en":"Serum Enzymes Absorption spectrophotometry 801 - Clinical Biochemistry Absorption spectrophotometry RD02SOP041AST, issue No. 5; RD02SOP042GGT, issue No. 5; AU480","search_zh":"血清 酶 吸收分光光度法 801 - 临床生物化学 吸收分光光度法 RD02SOP041AST, 第5版; RD02SOP042GGT, 第5版; AU480","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","reference_pl":"RD02SOP041AST, wydanie nr 5; RD02SOP042GGT, wydanie nr 5; AU480","reference_en":"RD02SOP041AST, issue No. 5; RD02SOP042GGT, issue No. 5; AU480","methodology_de":"Enzyme","reference_de":"RD02SOP041AST, Ausgabe Nr. 5; RD02SOP042GGT, Ausgabe Nr. 5; AU480","regulatory_area_de":"801 - Klinische Biochemie","search_de":"Serum Enzyme Absorptionsspektrophotometrie 801 - Klinische Biochemie Absorptionsspektrophotometrie RD02SOP041AST, Ausgabe Nr. 5; RD02SOP042GGT, Ausgabe Nr. 5; AU480","technique_de":"Absorptionsspektrophotometrie","techniques_de":["Absorptionsspektrophotometrie"],"test_object_de":"Serum","reference_zh":"RD02SOP041AST, 第5版; RD02SOP042GGT, 第5版; AU480"},{"_id":"04e795806f85cf3e7273e74a","lab_id":"6af252d10ecd48de0c70590e","country":"CZ","accr_number":"8341","accr_body":"ČIA","row_label":"5","test_object":"Surowica","test_object_en":"Serum","test_object_zh":"血清","test_object_cs":"Sérum","methodology":"Lipidy","methodology_en":"Lipids","methodology_zh":"血脂","methodology_cs":"Lipidy","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Spektrofotometria absorpcyjna","technique_en":"Absorption spectrophotometry","technique_zh":"吸收分光光度法","technique_cs":"Absorpční spektrofotometrie","techniques":["Spektrofotometria absorpcyjna"],"techniques_en":["Absorption spectrophotometry"],"techniques_zh":["吸收分光光度法"],"techniques_cs":["Absorpční spektrofotometrie"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Lipidy\nSpektrofotometria absorpcyjna","reference":"RD02SOP057CHOL, vydání č. 5; RD02SOP059AST, vydání č. 5; AU480","norm_bases":["RD02SOP057CHOL","RD02SOP059AST"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"801 - Biochemia kliniczna","regulatory_area_en":"801 - Clinical Biochemistry","regulatory_area_zh":"801 - 临床生物化学","regulatory_area_cs":"801 - Klinická biochemie","flexible":false,"flexibility":null,"outside_premises":false,"note":"Cholesterol całkowity, triacyloglicerole (TAG)","note_en":"Total cholesterol, Triacylglycerols (TAG)","note_zh":"总胆固醇、三酰甘油（TAG）","note_cs":"Celkový cholesterol, Triacylglyceroly (TAG)","search_text":"Surowica Lipidy Spektrofotometria absorpcyjna Sérum Lipidy Absorpční spektrofotometrie RD02SOP057CHOL, vydání č. 5; RD02SOP059AST, vydání č. 5; AU480 Surowica Lipidy Spektrofotometria absorpcyjna Serum Lipidy Absorpcni spektrofotometrie RD02SOP057CHOL, vydani c. 5; RD02SOP059AST, vydani c. 5; AU480","search_en":"Serum Lipids Absorption spectrophotometry 801 - Clinical Biochemistry Absorption spectrophotometry RD02SOP057CHOL, issue No. 5; RD02SOP059AST, issue No. 5; AU480","search_zh":"血清 血脂 吸收分光光度法 801 - 临床生物化学 吸收分光光度法 RD02SOP057CHOL, 第5版; RD02SOP059AST, 第5版; AU480","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","reference_pl":"RD02SOP057CHOL, wydanie nr 5; RD02SOP059AST, wydanie nr 5; AU480","reference_en":"RD02SOP057CHOL, issue No. 5; RD02SOP059AST, issue No. 5; AU480","methodology_de":"Lipide","reference_de":"RD02SOP057CHOL, Ausgabe Nr. 5; RD02SOP059AST, Ausgabe Nr. 5; AU480","regulatory_area_de":"801 - Klinische Biochemie","search_de":"Serum Lipide Absorptionsspektrophotometrie 801 - Klinische Biochemie Absorptionsspektrophotometrie RD02SOP057CHOL, Ausgabe Nr. 5; RD02SOP059AST, Ausgabe Nr. 5; AU480","technique_de":"Absorptionsspektrophotometrie","techniques_de":["Absorptionsspektrophotometrie"],"test_object_de":"Serum","reference_zh":"RD02SOP057CHOL, 第5版; RD02SOP059AST, 第5版; AU480"}],"has_pdf":true}