{"lab":{"_id":"6ade8b5eff06824761708159","accr_number":"2433","country":"CZ","accr_body":"ČIA","address":"Kumburský Újezd 112, 509 01 Nová Paka","categories":["metrology"],"city":"Nová Paka","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[15.4992652,50.4766481]},"map_coord":[50.4766481,15.4992652],"map_geo":"cai-mapa","methods_count":5,"name":"RFspin s. r. o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie anten, w zakresie określonym w załączniku do świadectwa.","search_text":"rfspin s. r. o. kumburský újezd 112, 509 01 nová paka 2433","source_page_url":"https://www.cai.cz/?subjekt=2433-rfspin-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"06-10-2029","website":"www.rfspin.com","certificate_date":"06.10.2026","certificate_no":"453/2026","certificate_replaces":"","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie anten, w zakresie określonym w załączniku do świadectwa.","en":"Antenna calibration to the extent as specified in the appendix to this Certificate.","zh":"天线校准，范围见本证书附件。","cs":"Kalibrace antén, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące RFspin","lab_division_cs":"Kalibrační laboratoř RFspin","lab_division_en":"RFspin Calibration Laboratory","lab_division_zh":"RFspin 校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"ef2516ee3f6a44538d31f5ad457b46f669394e7b851d64b3d64cd292f7d9ad9c","source_pdf_url":"https://www.cai.cz/OA/pdf/453_2026_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/453_2026_EN.pdf"},"methods":[{"_id":"93b42bfb6eb2ecc4a4fa3664","lab_id":"6ade8b5eff06824761708159","country":"CZ","accr_number":"2433","accr_body":"ČIA","row_label":"1","test_object":"Współczynnik odbicia / anteny","test_object_en":"Reflection coefficient / antennas","test_object_zh":"反射系数 / 天线","test_object_cs":"Činitel odrazu / antény","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"0,5 GHz do 40 GHz","range":"od 0 dB do -6 dB","cmc":"0,21 dB"},{"name":"0,5 GHz do 40 GHz","range":"od -6 dB do -15 dB","cmc":"0,41 dB"},{"name":"0,5 GHz do 40 GHz","range":"od -15 dB do -25 dB","cmc":"1,4 dB"},{"name":"0,5 GHz do 40 GHz","range":"od -25 dB do -35 dB","cmc":"4,1 dB"}],"parameters_en":[{"name":"0,5 GHz to 40 GHz","range":"0 dB to -6 dB","cmc":"0,21 dB"},{"name":"0,5 GHz to 40 GHz","range":"-6 dB to -15 dB","cmc":"0,41 dB"},{"name":"0,5 GHz to 40 GHz","range":"-15 dB to -25 dB","cmc":"1,4 dB"},{"name":"0,5 GHz to 40 GHz","range":"-25 dB to -35 dB","cmc":"4,1 dB"}],"parameters_zh":[{"name":"0,5 GHz 至 40 GHz","range":"0 dB 至 -6 dB","cmc":"0,21 dB"},{"name":"0,5 GHz 至 40 GHz","range":"-6 dB 至 -15 dB","cmc":"0,41 dB"},{"name":"0,5 GHz 至 40 GHz","range":"-15 dB 至 -25 dB","cmc":"1,4 dB"},{"name":"0,5 GHz 至 40 GHz","range":"-25 dB 至 -35 dB","cmc":"4,1 dB"}],"parameters_cs":[{"name":"0,5 GHz až 40 GHz","range":"0 dB až -6 dB","cmc":"0,21 dB"},{"name":"0,5 GHz až 40 GHz","range":"-6 dB až -15 dB","cmc":"0,41 dB"},{"name":"0,5 GHz až 40 GHz","range":"-15 dB až -25 dB","cmc":"1,4 dB"},{"name":"0,5 GHz až 40 GHz","range":"-25 dB až -35 dB","cmc":"4,1 dB"}],"technique":"Pomiar wektorowym analizatorem obwodów","technique_en":"Vector network analyzer measurement","technique_zh":"用矢量网络分析仪测量","technique_cs":"Měření vektorovým obvodovým analyzátorem","techniques":["Pomiar wektorowym analizatorem obwodów"],"techniques_en":["Vector network analyzer measurement"],"techniques_zh":["用矢量网络分析仪测量"],"techniques_cs":["Měření vektorovým obvodovým analyzátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n0,5 GHz do 40 GHz od 0 dB do -6 dB CMC 0,21 dB\n0,5 GHz do 40 GHz od -6 dB do -15 dB CMC 0,41 dB\n0,5 GHz do 40 GHz od -15 dB do -25 dB CMC 1,4 dB\n0,5 GHz do 40 GHz od -25 dB do -35 dB CMC 4,1 dB\nPomiar wektorowym analizatorem obwodów","reference":"KP-02","norm_bases":["KP-02"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Współczynnik odbicia / anteny Wzorcowanie – wielkości elektryczne Pomiar wektorowym analizatorem obwodów 0,5 GHz do 40 GHz od 0 dB do -6 dB CMC 0,21 dB 0,5 GHz do 40 GHz od -6 dB do -15 dB CMC 0,41 dB 0,5 GHz do 40 GHz od -15 dB do -25 dB CMC 1,4 dB 0,5 GHz do 40 GHz od -25 dB do -35 dB CMC 4,1 dB Činitel odrazu / antény Kalibrace – elektrické veličiny Měření vektorovým obvodovým analyzátorem 0,5 GHz až 40 GHz 0 dB až -6 dB CMC 0,21 dB 0,5 GHz až 40 GHz -6 dB až -15 dB CMC 0,41 dB 0,5 GHz až 40 GHz -15 dB až -25 dB CMC 1,4 dB 0,5 GHz až 40 GHz -25 dB až -35 dB CMC 4,1 dB KP-02 Wspolczynnik odbicia / anteny Wzorcowanie – wielkosci elektryczne Pomiar wektorowym analizatorem obwodow 0,5 GHz do 40 GHz od 0 dB do -6 dB CMC 0,21 dB 0,5 GHz do 40 GHz od -6 dB do -15 dB CMC 0,41 dB 0,5 GHz do 40 GHz od -15 dB do -25 dB CMC 1,4 dB 0,5 GHz do 40 GHz od -25 dB do -35 dB CMC 4,1 dB Cinitel odrazu / anteny Kalibrace – elektricke veliciny Mereni vektorovym obvodovym analyzatorem 0,5 GHz az 40 GHz 0 dB az -6 dB CMC 0,21 dB 0,5 GHz az 40 GHz -6 dB az -15 dB CMC 0,41 dB 0,5 GHz az 40 GHz -15 dB az -25 dB CMC 1,4 dB 0,5 GHz az 40 GHz -25 dB az -35 dB CMC 4,1 dB KP-02","search_en":"Reflection coefficient / antennas Calibration – electrical quantities Vector network analyzer measurement 0,5 GHz to 40 GHz 0 dB to -6 dB CMC 0,21 dB 0,5 GHz to 40 GHz -6 dB to -15 dB CMC 0,41 dB 0,5 GHz to 40 GHz -15 dB to -25 dB CMC 1,4 dB 0,5 GHz to 40 GHz -25 dB to -35 dB CMC 4,1 dB KP-02","search_zh":"反射系数 / 天线 校准 – 电学量 用矢量网络分析仪测量 0,5 GHz 至 40 GHz 0 dB 至 -6 dB CMC 0,21 dB 0,5 GHz 至 40 GHz -6 dB 至 -15 dB CMC 0,41 dB 0,5 GHz 至 40 GHz -15 dB 至 -25 dB CMC 1,4 dB 0,5 GHz 至 40 GHz -25 dB 至 -35 dB CMC 4,1 dB KP-02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9ea16c6f7c48b26fcbc83cab","lab_id":"6ade8b5eff06824761708159","country":"CZ","accr_number":"2433","accr_body":"ČIA","row_label":"2","test_object":"Zysk / anteny","test_object_en":"Gain / antennas","test_object_zh":"增益 / 天线","test_object_cs":"Zisk / antény","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"Odległość 1 m; 0,5 GHz do 40 GHz","range":"od -10 dB do 40 dB","cmc":"0,8 dB"}],"parameters_en":[{"name":"Distance: 1 m; 0,5 GHz to 40 GHz","range":"-10 dB to 40 dB","cmc":"0,8 dB"}],"parameters_zh":[{"name":"距离 1 m；0,5 GHz 至 40 GHz","range":"-10 dB 至 40 dB","cmc":"0,8 dB"}],"parameters_cs":[{"name":"Vzdálenost 1 m; 0,5 GHz až 40 GHz","range":"-10 dB až 40 dB","cmc":"0,8 dB"}],"technique":"Metoda trzech anten","technique_en":"Three-antenna method","technique_zh":"三天线法","technique_cs":"Metoda tří antén","techniques":["Metoda trzech anten"],"techniques_en":["Three-antenna method"],"techniques_zh":["三天线法"],"techniques_cs":["Metoda tří antén"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nOdległość 1 m; 0,5 GHz do 40 GHz od -10 dB do 40 dB CMC 0,8 dB\nMetoda trzech anten","reference":"KP-01 (SAE ARP 958E, kap. 4)","norm_bases":["KP-01","SAE ARP 958E"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Zysk / anteny Wzorcowanie – wielkości elektryczne Metoda trzech anten Odległość 1 m; 0,5 GHz do 40 GHz od -10 dB do 40 dB CMC 0,8 dB Zisk / antény Kalibrace – elektrické veličiny Metoda tří antén Vzdálenost 1 m; 0,5 GHz až 40 GHz -10 dB až 40 dB CMC 0,8 dB KP-01 (SAE ARP 958E, kap. 4) Zysk / anteny Wzorcowanie – wielkosci elektryczne Metoda trzech anten Odleglosc 1 m; 0,5 GHz do 40 GHz od -10 dB do 40 dB CMC 0,8 dB Zisk / anteny Kalibrace – elektricke veliciny Metoda tri anten Vzdalenost 1 m; 0,5 GHz az 40 GHz -10 dB az 40 dB CMC 0,8 dB KP-01 (SAE ARP 958E, kap. 4)","search_en":"Gain / antennas Calibration – electrical quantities Three-antenna method Distance: 1 m; 0,5 GHz to 40 GHz -10 dB to 40 dB CMC 0,8 dB KP-01 (SAE ARP 958E, kap. 4)","search_zh":"增益 / 天线 校准 – 电学量 三天线法 距离 1 m；0,5 GHz 至 40 GHz -10 dB 至 40 dB CMC 0,8 dB KP-01 (SAE ARP 958E, kap. 4)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4f6a8a9f06179ac945ffb2b7","lab_id":"6ade8b5eff06824761708159","country":"CZ","accr_number":"2433","accr_body":"ČIA","row_label":"2","test_object":"Zysk / anteny","test_object_en":"Gain / antennas","test_object_zh":"增益 / 天线","test_object_cs":"Zisk / antény","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"Odległość 3 m; 0,5 GHz do 40 GHz","range":"od -10 dB do 40 dB","cmc":"0,7 dB"}],"parameters_en":[{"name":"Distance: 3 m; 0,5 GHz to 40 GHz","range":"-10 dB to 40 dB","cmc":"0,7 dB"}],"parameters_zh":[{"name":"距离 3 m；0,5 GHz 至 40 GHz","range":"-10 dB 至 40 dB","cmc":"0,7 dB"}],"parameters_cs":[{"name":"Vzdálenost 3 m; 0,5 GHz až 40 GHz","range":"-10 dB až 40 dB","cmc":"0,7 dB"}],"technique":"Metoda trzech anten","technique_en":"Three-antenna method","technique_zh":"三天线法","technique_cs":"Metoda tří antén","techniques":["Metoda trzech anten"],"techniques_en":["Three-antenna method"],"techniques_zh":["三天线法"],"techniques_cs":["Metoda tří antén"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nOdległość 3 m; 0,5 GHz do 40 GHz od -10 dB do 40 dB CMC 0,7 dB\nMetoda trzech anten","reference":"KP-01 (ANSI C63.5, kap. 5)","norm_bases":["KP-01","ANSI C63.5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Zysk / anteny Wzorcowanie – wielkości elektryczne Metoda trzech anten Odległość 3 m; 0,5 GHz do 40 GHz od -10 dB do 40 dB CMC 0,7 dB Zisk / antény Kalibrace – elektrické veličiny Metoda tří antén Vzdálenost 3 m; 0,5 GHz až 40 GHz -10 dB až 40 dB CMC 0,7 dB KP-01 (ANSI C63.5, kap. 5) Zysk / anteny Wzorcowanie – wielkosci elektryczne Metoda trzech anten Odleglosc 3 m; 0,5 GHz do 40 GHz od -10 dB do 40 dB CMC 0,7 dB Zisk / anteny Kalibrace – elektricke veliciny Metoda tri anten Vzdalenost 3 m; 0,5 GHz az 40 GHz -10 dB az 40 dB CMC 0,7 dB KP-01 (ANSI C63.5, kap. 5)","search_en":"Gain / antennas Calibration – electrical quantities Three-antenna method Distance: 3 m; 0,5 GHz to 40 GHz -10 dB to 40 dB CMC 0,7 dB KP-01 (ANSI C63.5, kap. 5)","search_zh":"增益 / 天线 校准 – 电学量 三天线法 距离 3 m；0,5 GHz 至 40 GHz -10 dB 至 40 dB CMC 0,7 dB KP-01 (ANSI C63.5, kap. 5)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dbad5782f2b3e18384e32d08","lab_id":"6ade8b5eff06824761708159","country":"CZ","accr_number":"2433","accr_body":"ČIA","row_label":"3","test_object":"Współczynnik antenowy / anteny","test_object_en":"Antenna factor / antennas","test_object_zh":"天线系数 / 天线","test_object_cs":"Anténní faktor / antény","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"Odległość 1 m; 0,5 GHz do 40 GHz","range":"od -16 dB (m⁻¹) do 72 dB (m⁻¹)","cmc":"0,8 dB"}],"parameters_en":[{"name":"Distance: 1 m; 0,5 GHz to 40 GHz","range":"-16 dB (m⁻¹) to 72 dB (m⁻¹)","cmc":"0,8 dB"}],"parameters_zh":[{"name":"距离 1 m；0,5 GHz 至 40 GHz","range":"-16 dB (m⁻¹) 至 72 dB (m⁻¹)","cmc":"0,8 dB"}],"parameters_cs":[{"name":"Vzdálenost 1 m; 0,5 GHz až 40 GHz","range":"-16 dB (m⁻¹) až 72 dB (m⁻¹)","cmc":"0,8 dB"}],"technique":"Metoda trzech anten","technique_en":"Three-antenna method","technique_zh":"三天线法","technique_cs":"Metoda tří antén","techniques":["Metoda trzech anten"],"techniques_en":["Three-antenna method"],"techniques_zh":["三天线法"],"techniques_cs":["Metoda tří antén"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nOdległość 1 m; 0,5 GHz do 40 GHz od -16 dB (m⁻¹) do 72 dB (m⁻¹) CMC 0,8 dB\nMetoda trzech anten","reference":"KP-01 (SAE ARP 958E, kap. 4)","norm_bases":["KP-01","SAE ARP 958E"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Współczynnik antenowy / anteny Wzorcowanie – wielkości elektryczne Metoda trzech anten Odległość 1 m; 0,5 GHz do 40 GHz od -16 dB (m⁻¹) do 72 dB (m⁻¹) CMC 0,8 dB Anténní faktor / antény Kalibrace – elektrické veličiny Metoda tří antén Vzdálenost 1 m; 0,5 GHz až 40 GHz -16 dB (m⁻¹) až 72 dB (m⁻¹) CMC 0,8 dB KP-01 (SAE ARP 958E, kap. 4) Wspolczynnik antenowy / anteny Wzorcowanie – wielkosci elektryczne Metoda trzech anten Odleglosc 1 m; 0,5 GHz do 40 GHz od -16 dB (m⁻¹) do 72 dB (m⁻¹) CMC 0,8 dB Antenni faktor / anteny Kalibrace – elektricke veliciny Metoda tri anten Vzdalenost 1 m; 0,5 GHz az 40 GHz -16 dB (m⁻¹) az 72 dB (m⁻¹) CMC 0,8 dB KP-01 (SAE ARP 958E, kap. 4)","search_en":"Antenna factor / antennas Calibration – electrical quantities Three-antenna method Distance: 1 m; 0,5 GHz to 40 GHz -16 dB (m⁻¹) to 72 dB (m⁻¹) CMC 0,8 dB KP-01 (SAE ARP 958E, kap. 4)","search_zh":"天线系数 / 天线 校准 – 电学量 三天线法 距离 1 m；0,5 GHz 至 40 GHz -16 dB (m⁻¹) 至 72 dB (m⁻¹) CMC 0,8 dB KP-01 (SAE ARP 958E, kap. 4)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"47edbe30b4ac002dda48dac7","lab_id":"6ade8b5eff06824761708159","country":"CZ","accr_number":"2433","accr_body":"ČIA","row_label":"3","test_object":"Współczynnik antenowy / anteny","test_object_en":"Antenna factor / antennas","test_object_zh":"天线系数 / 天线","test_object_cs":"Anténní faktor / antény","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"Odległość 3 m; 0,5 GHz do 40 GHz","range":"od -16 dB (m⁻¹) do 72 dB (m⁻¹)","cmc":"0,7 dB"}],"parameters_en":[{"name":"Distance: 3 m; 0,5 GHz to 40 GHz","range":"-16 dB (m⁻¹) to 72 dB (m⁻¹)","cmc":"0,7 dB"}],"parameters_zh":[{"name":"距离 3 m；0,5 GHz 至 40 GHz","range":"-16 dB (m⁻¹) 至 72 dB (m⁻¹)","cmc":"0,7 dB"}],"parameters_cs":[{"name":"Vzdálenost 3 m; 0,5 GHz až 40 GHz","range":"-16 dB (m⁻¹) až 72 dB (m⁻¹)","cmc":"0,7 dB"}],"technique":"Metoda trzech anten","technique_en":"Three-antenna method","technique_zh":"三天线法","technique_cs":"Metoda tří antén","techniques":["Metoda trzech anten"],"techniques_en":["Three-antenna method"],"techniques_zh":["三天线法"],"techniques_cs":["Metoda tří antén"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nOdległość 3 m; 0,5 GHz do 40 GHz od -16 dB (m⁻¹) do 72 dB (m⁻¹) CMC 0,7 dB\nMetoda trzech anten","reference":"KP-01 (ANSI C63.5, kap. 5)","norm_bases":["KP-01","ANSI C63.5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Współczynnik antenowy / anteny Wzorcowanie – wielkości elektryczne Metoda trzech anten Odległość 3 m; 0,5 GHz do 40 GHz od -16 dB (m⁻¹) do 72 dB (m⁻¹) CMC 0,7 dB Anténní faktor / antény Kalibrace – elektrické veličiny Metoda tří antén Vzdálenost 3 m; 0,5 GHz až 40 GHz -16 dB (m⁻¹) až 72 dB (m⁻¹) CMC 0,7 dB KP-01 (ANSI C63.5, kap. 5) Wspolczynnik antenowy / anteny Wzorcowanie – wielkosci elektryczne Metoda trzech anten Odleglosc 3 m; 0,5 GHz do 40 GHz od -16 dB (m⁻¹) do 72 dB (m⁻¹) CMC 0,7 dB Antenni faktor / anteny Kalibrace – elektricke veliciny Metoda tri anten Vzdalenost 3 m; 0,5 GHz az 40 GHz -16 dB (m⁻¹) az 72 dB (m⁻¹) CMC 0,7 dB KP-01 (ANSI C63.5, kap. 5)","search_en":"Antenna factor / antennas Calibration – electrical quantities Three-antenna method Distance: 3 m; 0,5 GHz to 40 GHz -16 dB (m⁻¹) to 72 dB (m⁻¹) CMC 0,7 dB KP-01 (ANSI C63.5, kap. 5)","search_zh":"天线系数 / 天线 校准 – 电学量 三天线法 距离 3 m；0,5 GHz 至 40 GHz -16 dB (m⁻¹) 至 72 dB (m⁻¹) CMC 0,7 dB KP-01 (ANSI C63.5, kap. 5)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}