{"lab":{"_id":"6ade8b5dff06824761708157","accr_number":"2430","country":"CZ","accr_body":"ČIA","address":"Rychnovská 408, Letňany, 199 00 Praha 9","categories":["metrology"],"city":"Praha 9","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[14.5115842,50.1355638]},"map_coord":[50.1355638,14.5115842],"map_geo":"cai-mapa","methods_count":13,"name":"Metra LAB solution s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinie wielkości elektrycznych i wielkości częstotliwości, w zakresie określonym w załączniku do świadectwa.","search_text":"metra lab solution s.r.o. rychnovská 408, letňany, 199 00 praha 9 2430","source_page_url":"https://www.cai.cz/?subjekt=2430-metra-lab-solution-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"02-04-2029","website":"","certificate_date":"25.06.2026","certificate_no":"311/2026","certificate_replaces":"166/2026 z 02.04.2026","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinie wielkości elektrycznych i wielkości częstotliwości, w zakresie określonym w załączniku do świadectwa.","en":"Calibration in the field of electrical quantities and frequency quantities to the extent as specified in the appendix to this Certificate.","zh":"电学量和频率量领域的校准，范围见本证书附件。","cs":"Kalibrace v oboru elektrických veličin a veličin frekvence, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Metra LAB","lab_division_cs":"Metra LAB","lab_division_en":"Metra LAB","lab_division_zh":"Metra LAB 实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"427152787dc167d0b64ba6b258e76223cd4537b9ab34627f6d1030591a9c7d3e","source_pdf_url":"https://www.cai.cz/OA/pdf/311_2026_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/311_2026_EN.pdf"},"methods":[{"_id":"551c4b5c0619009fe799da40","lab_id":"6ade8b5dff06824761708157","country":"CZ","accr_number":"2430","accr_body":"ČIA","row_label":"1","test_object":"Napięcie stałe / źródła i wzorce napięcia stałego","test_object_en":"DC voltage / DC voltage sources and reference standards","test_object_zh":"直流电压 / 直流电压源和标准器","test_object_cs":"Stejnosměrné napětí / zdroje a etalony stejnosměrného napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mV do 120 mV","cmc":"0,0011 % + 0,8 µV"},{"name":"","range":"od 120 mV do 1,2 V","cmc":"0,00097 % + 1,3 µV"},{"name":"","range":"od 1,2 V do 12 V","cmc":"0,00097 %"},{"name":"","range":"od 12 V do 120 V","cmc":"0,00017 %"},{"name":"","range":"od 120 V do 1 kV","cmc":"0,0034 %"}],"parameters_en":[{"name":"","range":"0 mV to 120 mV","cmc":"0,0011 % + 0,8 µV"},{"name":"","range":"120 mV to 1,2 V","cmc":"0,00097 % + 1,3 µV"},{"name":"","range":"1,2 V to 12 V","cmc":"0,00097 %"},{"name":"","range":"12 V to 120 V","cmc":"0,00017 %"},{"name":"","range":"120 V to 1 kV","cmc":"0,0034 %"}],"parameters_zh":[{"name":"","range":"0 mV 至 120 mV","cmc":"0,0011 % + 0,8 µV"},{"name":"","range":"120 mV 至 1,2 V","cmc":"0,00097 % + 1,3 µV"},{"name":"","range":"1,2 V 至 12 V","cmc":"0,00097 %"},{"name":"","range":"12 V 至 120 V","cmc":"0,00017 %"},{"name":"","range":"120 V 至 1 kV","cmc":"0,0034 %"}],"parameters_cs":[{"name":"","range":"0 mV až 120 mV","cmc":"0,0011 % + 0,8 µV"},{"name":"","range":"120 mV až 1,2 V","cmc":"0,00097 % + 1,3 µV"},{"name":"","range":"1,2 V až 12 V","cmc":"0,00097 %"},{"name":"","range":"12 V až 120 V","cmc":"0,00017 %"},{"name":"","range":"120 V až 1 kV","cmc":"0,0034 %"}],"technique":"Pomiar bezpośredni multimetrem wzorcowym","technique_en":"Direct measurement by a reference multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Pomiar bezpośredni multimetrem wzorcowym"],"techniques_en":["Direct measurement by a reference multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mV do 120 mV CMC 0,0011 % + 0,8 µV\nod 120 mV do 1,2 V CMC 0,00097 % + 1,3 µV\nod 1,2 V do 12 V CMC 0,00097 %\nod 12 V do 120 V CMC 0,00017 %\nod 120 V do 1 kV CMC 0,0034 %\nPomiar bezpośredni multimetrem wzorcowym","reference":"CP-001","norm_bases":["CP-001"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / źródła i wzorce napięcia stałego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem wzorcowym od 0 mV do 120 mV CMC 0,0011 % + 0,8 µV od 120 mV do 1,2 V CMC 0,00097 % + 1,3 µV od 1,2 V do 12 V CMC 0,00097 % od 12 V do 120 V CMC 0,00017 % od 120 V do 1 kV CMC 0,0034 % Stejnosměrné napětí / zdroje a etalony stejnosměrného napětí Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem 0 mV až 120 mV CMC 0,0011 % + 0,8 µV 120 mV až 1,2 V CMC 0,00097 % + 1,3 µV 1,2 V až 12 V CMC 0,00097 % 12 V až 120 V CMC 0,00017 % 120 V až 1 kV CMC 0,0034 % CP-001 Napiecie stale / zrodla i wzorce napiecia stalego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem wzorcowym od 0 mV do 120 mV CMC 0,0011 % + 0,8 µV od 120 mV do 1,2 V CMC 0,00097 % + 1,3 µV od 1,2 V do 12 V CMC 0,00097 % od 12 V do 120 V CMC 0,00017 % od 120 V do 1 kV CMC 0,0034 % Stejnosmerne napeti / zdroje a etalony stejnosmerneho napeti Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem 0 mV az 120 mV CMC 0,0011 % + 0,8 µV 120 mV az 1,2 V CMC 0,00097 % + 1,3 µV 1,2 V az 12 V CMC 0,00097 % 12 V az 120 V CMC 0,00017 % 120 V az 1 kV CMC 0,0034 % CP-001","search_en":"DC voltage / DC voltage sources and reference standards Calibration – electrical quantities Direct measurement by a reference multimeter 0 mV to 120 mV CMC 0,0011 % + 0,8 µV 120 mV to 1,2 V CMC 0,00097 % + 1,3 µV 1,2 V to 12 V CMC 0,00097 % 12 V to 120 V CMC 0,00017 % 120 V to 1 kV CMC 0,0034 % CP-001","search_zh":"直流电压 / 直流电压源和标准器 校准 – 电学量 用标准万用表直接测量 0 mV 至 120 mV CMC 0,0011 % + 0,8 µV 120 mV 至 1,2 V CMC 0,00097 % + 1,3 µV 1,2 V 至 12 V CMC 0,00097 % 12 V 至 120 V CMC 0,00017 % 120 V 至 1 kV CMC 0,0034 % CP-001","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d964c83e8511eea9fcd2e8d6","lab_id":"6ade8b5dff06824761708157","country":"CZ","accr_number":"2430","accr_body":"ČIA","row_label":"2","test_object":"Napięcie stałe / mierniki napięcia stałego","test_object_en":"DC voltage / DC voltage meters","test_object_zh":"直流电压 / 直流电压测量仪器","test_object_cs":"Stejnosměrné napětí / měřidla stejnosměrného napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mV do 220 mV","cmc":"0,00078 % + 0,4 µV"},{"name":"","range":"od 220 mV do 2,2 V","cmc":"0,00049 % + 0,7 µV"},{"name":"","range":"od 2,2 V do 11 V","cmc":"0,00036 % + 3 µV"},{"name":"","range":"od 11 V do 22 V","cmc":"0,00045 % + 4 µV"},{"name":"","range":"od 22 V do 220 V","cmc":"0,00067 %"},{"name":"","range":"od 220 V do 1000 V","cmc":"0,00078 %"}],"parameters_en":[{"name":"","range":"0 mV to 220 mV","cmc":"0,00078 % + 0,4 µV"},{"name":"","range":"220 mV to 2,2 V","cmc":"0,00049 % + 0,7 µV"},{"name":"","range":"2,2 V to 11 V","cmc":"0,00036 % + 3 µV"},{"name":"","range":"11 V to 22 V","cmc":"0,00045 % + 4 µV"},{"name":"","range":"22 V to 220 V","cmc":"0,00067 %"},{"name":"","range":"220 V to 1000 V","cmc":"0,00078 %"}],"parameters_zh":[{"name":"","range":"0 mV 至 220 mV","cmc":"0,00078 % + 0,4 µV"},{"name":"","range":"220 mV 至 2,2 V","cmc":"0,00049 % + 0,7 µV"},{"name":"","range":"2,2 V 至 11 V","cmc":"0,00036 % + 3 µV"},{"name":"","range":"11 V 至 22 V","cmc":"0,00045 % + 4 µV"},{"name":"","range":"22 V 至 220 V","cmc":"0,00067 %"},{"name":"","range":"220 V 至 1000 V","cmc":"0,00078 %"}],"parameters_cs":[{"name":"","range":"0 mV až 220 mV","cmc":"0,00078 % + 0,4 µV"},{"name":"","range":"220 mV až 2,2 V","cmc":"0,00049 % + 0,7 µV"},{"name":"","range":"2,2 V až 11 V","cmc":"0,00036 % + 3 µV"},{"name":"","range":"11 V až 22 V","cmc":"0,00045 % + 4 µV"},{"name":"","range":"22 V až 220 V","cmc":"0,00067 %"},{"name":"","range":"220 V až 1000 V","cmc":"0,00078 %"}],"technique":"Generowanie kalibratorem","technique_en":"Generation using a calibrator","technique_zh":"用校准器产生","technique_cs":"Generování kalibrátorem","techniques":["Generowanie kalibratorem"],"techniques_en":["Generation using a calibrator"],"techniques_zh":["用校准器产生"],"techniques_cs":["Generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mV do 220 mV CMC 0,00078 % + 0,4 µV\nod 220 mV do 2,2 V CMC 0,00049 % + 0,7 µV\nod 2,2 V do 11 V CMC 0,00036 % + 3 µV\nod 11 V do 22 V CMC 0,00045 % + 4 µV\nod 22 V do 220 V CMC 0,00067 %\nod 220 V do 1000 V CMC 0,00078 %\nGenerowanie kalibratorem","reference":"CP-001","norm_bases":["CP-001"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / mierniki napięcia stałego Wzorcowanie – wielkości elektryczne Generowanie kalibratorem od 0 mV do 220 mV CMC 0,00078 % + 0,4 µV od 220 mV do 2,2 V CMC 0,00049 % + 0,7 µV od 2,2 V do 11 V CMC 0,00036 % + 3 µV od 11 V do 22 V CMC 0,00045 % + 4 µV od 22 V do 220 V CMC 0,00067 % od 220 V do 1000 V CMC 0,00078 % Stejnosměrné napětí / měřidla stejnosměrného napětí Kalibrace – elektrické veličiny Generování kalibrátorem 0 mV až 220 mV CMC 0,00078 % + 0,4 µV 220 mV až 2,2 V CMC 0,00049 % + 0,7 µV 2,2 V až 11 V CMC 0,00036 % + 3 µV 11 V až 22 V CMC 0,00045 % + 4 µV 22 V až 220 V CMC 0,00067 % 220 V až 1000 V CMC 0,00078 % CP-001 Napiecie stale / mierniki napiecia stalego Wzorcowanie – wielkosci elektryczne Generowanie kalibratorem od 0 mV do 220 mV CMC 0,00078 % + 0,4 µV od 220 mV do 2,2 V CMC 0,00049 % + 0,7 µV od 2,2 V do 11 V CMC 0,00036 % + 3 µV od 11 V do 22 V CMC 0,00045 % + 4 µV od 22 V do 220 V CMC 0,00067 % od 220 V do 1000 V CMC 0,00078 % Stejnosmerne napeti / meridla stejnosmerneho napeti Kalibrace – elektricke veliciny Generovani kalibratorem 0 mV az 220 mV CMC 0,00078 % + 0,4 µV 220 mV az 2,2 V CMC 0,00049 % + 0,7 µV 2,2 V az 11 V CMC 0,00036 % + 3 µV 11 V az 22 V CMC 0,00045 % + 4 µV 22 V az 220 V CMC 0,00067 % 220 V az 1000 V CMC 0,00078 % CP-001","search_en":"DC voltage / DC voltage meters Calibration – electrical quantities Generation using a calibrator 0 mV to 220 mV CMC 0,00078 % + 0,4 µV 220 mV to 2,2 V CMC 0,00049 % + 0,7 µV 2,2 V to 11 V CMC 0,00036 % + 3 µV 11 V to 22 V CMC 0,00045 % + 4 µV 22 V to 220 V CMC 0,00067 % 220 V to 1000 V CMC 0,00078 % CP-001","search_zh":"直流电压 / 直流电压测量仪器 校准 – 电学量 用校准器产生 0 mV 至 220 mV CMC 0,00078 % + 0,4 µV 220 mV 至 2,2 V CMC 0,00049 % + 0,7 µV 2,2 V 至 11 V CMC 0,00036 % + 3 µV 11 V 至 22 V CMC 0,00045 % + 4 µV 22 V 至 220 V CMC 0,00067 % 220 V 至 1000 V CMC 0,00078 % CP-001","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"145ddb638c55790e525d92fc","lab_id":"6ade8b5dff06824761708157","country":"CZ","accr_number":"2430","accr_body":"ČIA","row_label":"3","test_object":"Prąd stały / źródła i wzorce prądu stałego","test_object_en":"DC current / DC current sources and reference standards","test_object_zh":"直流电流 / 直流电流源和标准器","test_object_cs":"Stejnosměrný proud / zdroje a etalony stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 120 nA do 1,2 µA","cmc":"0,86 nA"},{"name":"","range":"od 1,2 µA do 12 µA","cmc":"0,74 nA"},{"name":"","range":"od 12 µA do 120 µA","cmc":"0,01 %"},{"name":"","range":"od 120 µA do 1,2 mA","cmc":"0,007 %"},{"name":"","range":"od 1,2 mA do 12 mA","cmc":"0,007 %"},{"name":"","range":"od 12 mA do 120 mA","cmc":"0,008 %"},{"name":"","range":"od 120 mA do 1 A","cmc":"0,021 %"}],"parameters_en":[{"name":"","range":"120 nA to 1,2 µA","cmc":"0,86 nA"},{"name":"","range":"1,2 µA to 12 µA","cmc":"0,74 nA"},{"name":"","range":"12 µA to 120 µA","cmc":"0,01 %"},{"name":"","range":"120 µA to 1,2 mA","cmc":"0,007 %"},{"name":"","range":"1,2 mA to 12 mA","cmc":"0,007 %"},{"name":"","range":"12 mA to 120 mA","cmc":"0,008 %"},{"name":"","range":"120 mA to 1 A","cmc":"0,021 %"}],"parameters_zh":[{"name":"","range":"120 nA 至 1,2 µA","cmc":"0,86 nA"},{"name":"","range":"1,2 µA 至 12 µA","cmc":"0,74 nA"},{"name":"","range":"12 µA 至 120 µA","cmc":"0,01 %"},{"name":"","range":"120 µA 至 1,2 mA","cmc":"0,007 %"},{"name":"","range":"1,2 mA 至 12 mA","cmc":"0,007 %"},{"name":"","range":"12 mA 至 120 mA","cmc":"0,008 %"},{"name":"","range":"120 mA 至 1 A","cmc":"0,021 %"}],"parameters_cs":[{"name":"","range":"120 nA až 1,2 µA","cmc":"0,86 nA"},{"name":"","range":"1,2 µA až 12 µA","cmc":"0,74 nA"},{"name":"","range":"12 µA až 120 µA","cmc":"0,01 %"},{"name":"","range":"120 µA až 1,2 mA","cmc":"0,007 %"},{"name":"","range":"1,2 mA až 12 mA","cmc":"0,007 %"},{"name":"","range":"12 mA až 120 mA","cmc":"0,008 %"},{"name":"","range":"120 mA až 1 A","cmc":"0,021 %"}],"technique":"Pomiar bezpośredni multimetrem wzorcowym","technique_en":"Direct measurement by a reference multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Pomiar bezpośredni multimetrem wzorcowym"],"techniques_en":["Direct measurement by a reference multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 120 nA do 1,2 µA CMC 0,86 nA\nod 1,2 µA do 12 µA CMC 0,74 nA\nod 12 µA do 120 µA CMC 0,01 %\nod 120 µA do 1,2 mA CMC 0,007 %\nod 1,2 mA do 12 mA CMC 0,007 %\nod 12 mA do 120 mA CMC 0,008 %\nod 120 mA do 1 A CMC 0,021 %\nPomiar bezpośredni multimetrem wzorcowym","reference":"CP-002","norm_bases":["CP-002"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / źródła i wzorce prądu stałego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem wzorcowym od 120 nA do 1,2 µA CMC 0,86 nA od 1,2 µA do 12 µA CMC 0,74 nA od 12 µA do 120 µA CMC 0,01 % od 120 µA do 1,2 mA CMC 0,007 % od 1,2 mA do 12 mA CMC 0,007 % od 12 mA do 120 mA CMC 0,008 % od 120 mA do 1 A CMC 0,021 % Stejnosměrný proud / zdroje a etalony stejnosměrného proudu Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem 120 nA až 1,2 µA CMC 0,86 nA 1,2 µA až 12 µA CMC 0,74 nA 12 µA až 120 µA CMC 0,01 % 120 µA až 1,2 mA CMC 0,007 % 1,2 mA až 12 mA CMC 0,007 % 12 mA až 120 mA CMC 0,008 % 120 mA až 1 A CMC 0,021 % CP-002 Prad staly / zrodla i wzorce pradu stalego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem wzorcowym od 120 nA do 1,2 µA CMC 0,86 nA od 1,2 µA do 12 µA CMC 0,74 nA od 12 µA do 120 µA CMC 0,01 % od 120 µA do 1,2 mA CMC 0,007 % od 1,2 mA do 12 mA CMC 0,007 % od 12 mA do 120 mA CMC 0,008 % od 120 mA do 1 A CMC 0,021 % Stejnosmerny proud / zdroje a etalony stejnosmerneho proudu Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem 120 nA az 1,2 µA CMC 0,86 nA 1,2 µA az 12 µA CMC 0,74 nA 12 µA az 120 µA CMC 0,01 % 120 µA az 1,2 mA CMC 0,007 % 1,2 mA az 12 mA CMC 0,007 % 12 mA az 120 mA CMC 0,008 % 120 mA az 1 A CMC 0,021 % CP-002","search_en":"DC current / DC current sources and reference standards Calibration – electrical quantities Direct measurement by a reference multimeter 120 nA to 1,2 µA CMC 0,86 nA 1,2 µA to 12 µA CMC 0,74 nA 12 µA to 120 µA CMC 0,01 % 120 µA to 1,2 mA CMC 0,007 % 1,2 mA to 12 mA CMC 0,007 % 12 mA to 120 mA CMC 0,008 % 120 mA to 1 A CMC 0,021 % CP-002","search_zh":"直流电流 / 直流电流源和标准器 校准 – 电学量 用标准万用表直接测量 120 nA 至 1,2 µA CMC 0,86 nA 1,2 µA 至 12 µA CMC 0,74 nA 12 µA 至 120 µA CMC 0,01 % 120 µA 至 1,2 mA CMC 0,007 % 1,2 mA 至 12 mA CMC 0,007 % 12 mA 至 120 mA CMC 0,008 % 120 mA 至 1 A CMC 0,021 % CP-002","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"63ad4037a966130f98efa4ee","lab_id":"6ade8b5dff06824761708157","country":"CZ","accr_number":"2430","accr_body":"ČIA","row_label":"3","test_object":"Prąd stały / źródła i wzorce prądu stałego","test_object_en":"DC current / DC current sources and reference standards","test_object_zh":"直流电流 / 直流电流源和标准器","test_object_cs":"Stejnosměrný proud / zdroje a etalony stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 1 A do 100 A","cmc":"0,052 %"}],"parameters_en":[{"name":"","range":"1 A to 100 A","cmc":"0,052 %"}],"parameters_zh":[{"name":"","range":"1 A 至 100 A","cmc":"0,052 %"}],"parameters_cs":[{"name":"","range":"1 A až 100 A","cmc":"0,052 %"}],"technique":"Pomiar pośredni bocznikiem wzorcowym i multimetrem","technique_en":"Indirect measurement using a reference shunt and multimeter","technique_zh":"用标准分流器和万用表间接测量","technique_cs":"Nepřímé měření etalonovým bočníkem a multimetrem","techniques":["Pomiar pośredni bocznikiem wzorcowym i multimetrem"],"techniques_en":["Indirect measurement using a reference shunt and multimeter"],"techniques_zh":["用标准分流器和万用表间接测量"],"techniques_cs":["Nepřímé měření etalonovým bočníkem a multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 1 A do 100 A CMC 0,052 %\nPomiar pośredni bocznikiem wzorcowym i multimetrem","reference":"CP-002","norm_bases":["CP-002"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / źródła i wzorce prądu stałego Wzorcowanie – wielkości elektryczne Pomiar pośredni bocznikiem wzorcowym i multimetrem od 1 A do 100 A CMC 0,052 % Stejnosměrný proud / zdroje a etalony stejnosměrného proudu Kalibrace – elektrické veličiny Nepřímé měření etalonovým bočníkem a multimetrem 1 A až 100 A CMC 0,052 % CP-002 Prad staly / zrodla i wzorce pradu stalego Wzorcowanie – wielkosci elektryczne Pomiar posredni bocznikiem wzorcowym i multimetrem od 1 A do 100 A CMC 0,052 % Stejnosmerny proud / zdroje a etalony stejnosmerneho proudu Kalibrace – elektricke veliciny Neprime mereni etalonovym bocnikem a multimetrem 1 A az 100 A CMC 0,052 % CP-002","search_en":"DC current / DC current sources and reference standards Calibration – electrical quantities Indirect measurement using a reference shunt and multimeter 1 A to 100 A CMC 0,052 % CP-002","search_zh":"直流电流 / 直流电流源和标准器 校准 – 电学量 用标准分流器和万用表间接测量 1 A 至 100 A CMC 0,052 % CP-002","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a6c7ef8c5e7467f7e2c041bb","lab_id":"6ade8b5dff06824761708157","country":"CZ","accr_number":"2430","accr_body":"ČIA","row_label":"4","test_object":"Prąd stały / mierniki prądu stałego","test_object_en":"DC current / DC current meters","test_object_zh":"直流电流 / 直流电流测量仪器","test_object_cs":"Stejnosměrný proud / měřidla stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 µA do 220 µA","cmc":"0,0040 % + 6 nA"},{"name":"","range":"od 220 µA do 2,2 mA","cmc":"0,0032 % + 7 nA"},{"name":"","range":"od 2,2 mA do 22 mA","cmc":"0,0032 % + 39 nA"},{"name":"","range":"od 22 mA do 220 mA","cmc":"0,0041 % + 0,7 µA"},{"name":"","range":"od 220 mA do 2,2 A","cmc":"0,0073 %"}],"parameters_en":[{"name":"","range":"0 µA to 220 µA","cmc":"0,0040 % + 6 nA"},{"name":"","range":"220 µA to 2,2 mA","cmc":"0,0032 % + 7 nA"},{"name":"","range":"2,2 mA to 22 mA","cmc":"0,0032 % + 39 nA"},{"name":"","range":"22 mA to 220 mA","cmc":"0,0041 % + 0,7 µA"},{"name":"","range":"220 mA to 2,2 A","cmc":"0,0073 %"}],"parameters_zh":[{"name":"","range":"0 µA 至 220 µA","cmc":"0,0040 % + 6 nA"},{"name":"","range":"220 µA 至 2,2 mA","cmc":"0,0032 % + 7 nA"},{"name":"","range":"2,2 mA 至 22 mA","cmc":"0,0032 % + 39 nA"},{"name":"","range":"22 mA 至 220 mA","cmc":"0,0041 % + 0,7 µA"},{"name":"","range":"220 mA 至 2,2 A","cmc":"0,0073 %"}],"parameters_cs":[{"name":"","range":"0 µA až 220 µA","cmc":"0,0040 % + 6 nA"},{"name":"","range":"220 µA až 2,2 mA","cmc":"0,0032 % + 7 nA"},{"name":"","range":"2,2 mA až 22 mA","cmc":"0,0032 % + 39 nA"},{"name":"","range":"22 mA až 220 mA","cmc":"0,0041 % + 0,7 µA"},{"name":"","range":"220 mA až 2,2 A","cmc":"0,0073 %"}],"technique":"Generowanie kalibratorem","technique_en":"Generation using a calibrator","technique_zh":"用校准器产生","technique_cs":"Generování kalibrátorem","techniques":["Generowanie kalibratorem"],"techniques_en":["Generation using a calibrator"],"techniques_zh":["用校准器产生"],"techniques_cs":["Generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 µA do 220 µA CMC 0,0040 % + 6 nA\nod 220 µA do 2,2 mA CMC 0,0032 % + 7 nA\nod 2,2 mA do 22 mA CMC 0,0032 % + 39 nA\nod 22 mA do 220 mA CMC 0,0041 % + 0,7 µA\nod 220 mA do 2,2 A CMC 0,0073 %\nGenerowanie kalibratorem","reference":"CP-002","norm_bases":["CP-002"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / mierniki prądu stałego Wzorcowanie – wielkości elektryczne Generowanie kalibratorem od 0 µA do 220 µA CMC 0,0040 % + 6 nA od 220 µA do 2,2 mA CMC 0,0032 % + 7 nA od 2,2 mA do 22 mA CMC 0,0032 % + 39 nA od 22 mA do 220 mA CMC 0,0041 % + 0,7 µA od 220 mA do 2,2 A CMC 0,0073 % Stejnosměrný proud / měřidla stejnosměrného proudu Kalibrace – elektrické veličiny Generování kalibrátorem 0 µA až 220 µA CMC 0,0040 % + 6 nA 220 µA až 2,2 mA CMC 0,0032 % + 7 nA 2,2 mA až 22 mA CMC 0,0032 % + 39 nA 22 mA až 220 mA CMC 0,0041 % + 0,7 µA 220 mA až 2,2 A CMC 0,0073 % CP-002 Prad staly / mierniki pradu stalego Wzorcowanie – wielkosci elektryczne Generowanie kalibratorem od 0 µA do 220 µA CMC 0,0040 % + 6 nA od 220 µA do 2,2 mA CMC 0,0032 % + 7 nA od 2,2 mA do 22 mA CMC 0,0032 % + 39 nA od 22 mA do 220 mA CMC 0,0041 % + 0,7 µA od 220 mA do 2,2 A CMC 0,0073 % Stejnosmerny proud / meridla stejnosmerneho proudu Kalibrace – elektricke veliciny Generovani kalibratorem 0 µA az 220 µA CMC 0,0040 % + 6 nA 220 µA az 2,2 mA CMC 0,0032 % + 7 nA 2,2 mA az 22 mA CMC 0,0032 % + 39 nA 22 mA az 220 mA CMC 0,0041 % + 0,7 µA 220 mA az 2,2 A CMC 0,0073 % CP-002","search_en":"DC current / DC current meters Calibration – electrical quantities Generation using a calibrator 0 µA to 220 µA CMC 0,0040 % + 6 nA 220 µA to 2,2 mA CMC 0,0032 % + 7 nA 2,2 mA to 22 mA CMC 0,0032 % + 39 nA 22 mA to 220 mA CMC 0,0041 % + 0,7 µA 220 mA to 2,2 A CMC 0,0073 % CP-002","search_zh":"直流电流 / 直流电流测量仪器 校准 – 电学量 用校准器产生 0 µA 至 220 µA CMC 0,0040 % + 6 nA 220 µA 至 2,2 mA CMC 0,0032 % + 7 nA 2,2 mA 至 22 mA CMC 0,0032 % + 39 nA 22 mA 至 220 mA CMC 0,0041 % + 0,7 µA 220 mA 至 2,2 A CMC 0,0073 % CP-002","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"27be8381022f68c04def3820","lab_id":"6ade8b5dff06824761708157","country":"CZ","accr_number":"2430","accr_body":"ČIA","row_label":"5","test_object":"Rezystancja przy prądzie stałym / źródła i wzorce rezystancji","test_object_en":"DC resistance / DC resistance sources and reference standards","test_object_zh":"直流电阻 / 直流电阻源和标准器","test_object_cs":"Stejnosměrný odpor / zdroje a etalony stejnosměrného odporu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 Ω do 12 Ω","cmc":"0,002 % + 65 µΩ"},{"name":"","range":"od 12 Ω do 120 Ω","cmc":"0,0020 %"},{"name":"","range":"od 120 Ω do 1,2 kΩ","cmc":"0,0014 %"},{"name":"","range":"od 1,2 kΩ do 12 kΩ","cmc":"0,0013 %"},{"name":"","range":"od 12 kΩ do 120 kΩ","cmc":"0,0014 %"},{"name":"","range":"od 120 kΩ do 1,2 MΩ","cmc":"0,0033 %"},{"name":"","range":"od 1,2 MΩ do 12 MΩ","cmc":"0,014 %"},{"name":"","range":"od 12 MΩ do 120 MΩ","cmc":"0,083 %"},{"name":"","range":"od 120 MΩ do 1,2 GΩ","cmc":"0,82 %"}],"parameters_en":[{"name":"","range":"0 Ω to 12 Ω","cmc":"0,002 % + 65 µΩ"},{"name":"","range":"12 Ω to 120 Ω","cmc":"0,0020 %"},{"name":"","range":"120 Ω to 1,2 kΩ","cmc":"0,0014 %"},{"name":"","range":"1,2 kΩ to 12 kΩ","cmc":"0,0013 %"},{"name":"","range":"12 kΩ to 120 kΩ","cmc":"0,0014 %"},{"name":"","range":"120 kΩ to 1,2 MΩ","cmc":"0,0033 %"},{"name":"","range":"1,2 MΩ to 12 MΩ","cmc":"0,014 %"},{"name":"","range":"12 MΩ to 120 MΩ","cmc":"0,083 %"},{"name":"","range":"120 MΩ to 1,2 GΩ","cmc":"0,82 %"}],"parameters_zh":[{"name":"","range":"0 Ω 至 12 Ω","cmc":"0,002 % + 65 µΩ"},{"name":"","range":"12 Ω 至 120 Ω","cmc":"0,0020 %"},{"name":"","range":"120 Ω 至 1,2 kΩ","cmc":"0,0014 %"},{"name":"","range":"1,2 kΩ 至 12 kΩ","cmc":"0,0013 %"},{"name":"","range":"12 kΩ 至 120 kΩ","cmc":"0,0014 %"},{"name":"","range":"120 kΩ 至 1,2 MΩ","cmc":"0,0033 %"},{"name":"","range":"1,2 MΩ 至 12 MΩ","cmc":"0,014 %"},{"name":"","range":"12 MΩ 至 120 MΩ","cmc":"0,083 %"},{"name":"","range":"120 MΩ 至 1,2 GΩ","cmc":"0,82 %"}],"parameters_cs":[{"name":"","range":"0 Ω až 12 Ω","cmc":"0,002 % + 65 µΩ"},{"name":"","range":"12 Ω až 120 Ω","cmc":"0,0020 %"},{"name":"","range":"120 Ω až 1,2 kΩ","cmc":"0,0014 %"},{"name":"","range":"1,2 kΩ až 12 kΩ","cmc":"0,0013 %"},{"name":"","range":"12 kΩ až 120 kΩ","cmc":"0,0014 %"},{"name":"","range":"120 kΩ až 1,2 MΩ","cmc":"0,0033 %"},{"name":"","range":"1,2 MΩ až 12 MΩ","cmc":"0,014 %"},{"name":"","range":"12 MΩ až 120 MΩ","cmc":"0,083 %"},{"name":"","range":"120 MΩ až 1,2 GΩ","cmc":"0,82 %"}],"technique":"Pomiar bezpośredni multimetrem","technique_en":"Direct measurement using a multimeter","technique_zh":"用万用表直接测量","technique_cs":"Přímé měření multimetrem","techniques":["Pomiar bezpośredni multimetrem"],"techniques_en":["Direct measurement using a multimeter"],"techniques_zh":["用万用表直接测量"],"techniques_cs":["Přímé měření multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 Ω do 12 Ω CMC 0,002 % + 65 µΩ\nod 12 Ω do 120 Ω CMC 0,0020 %\nod 120 Ω do 1,2 kΩ CMC 0,0014 %\nod 1,2 kΩ do 12 kΩ CMC 0,0013 %\nod 12 kΩ do 120 kΩ CMC 0,0014 %\nod 120 kΩ do 1,2 MΩ CMC 0,0033 %\nod 1,2 MΩ do 12 MΩ CMC 0,014 %\nod 12 MΩ do 120 MΩ CMC 0,083 %\nod 120 MΩ do 1,2 GΩ CMC 0,82 %\nPomiar bezpośredni multimetrem","reference":"CP-003","norm_bases":["CP-003"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / źródła i wzorce rezystancji Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem od 0 Ω do 12 Ω CMC 0,002 % + 65 µΩ od 12 Ω do 120 Ω CMC 0,0020 % od 120 Ω do 1,2 kΩ CMC 0,0014 % od 1,2 kΩ do 12 kΩ CMC 0,0013 % od 12 kΩ do 120 kΩ CMC 0,0014 % od 120 kΩ do 1,2 MΩ CMC 0,0033 % od 1,2 MΩ do 12 MΩ CMC 0,014 % od 12 MΩ do 120 MΩ CMC 0,083 % od 120 MΩ do 1,2 GΩ CMC 0,82 % Stejnosměrný odpor / zdroje a etalony stejnosměrného odporu Kalibrace – elektrické veličiny Přímé měření multimetrem 0 Ω až 12 Ω CMC 0,002 % + 65 µΩ 12 Ω až 120 Ω CMC 0,0020 % 120 Ω až 1,2 kΩ CMC 0,0014 % 1,2 kΩ až 12 kΩ CMC 0,0013 % 12 kΩ až 120 kΩ CMC 0,0014 % 120 kΩ až 1,2 MΩ CMC 0,0033 % 1,2 MΩ až 12 MΩ CMC 0,014 % 12 MΩ až 120 MΩ CMC 0,083 % 120 MΩ až 1,2 GΩ CMC 0,82 % CP-003 Rezystancja przy pradzie stalym / zrodla i wzorce rezystancji Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem od 0 Ω do 12 Ω CMC 0,002 % + 65 µΩ od 12 Ω do 120 Ω CMC 0,0020 % od 120 Ω do 1,2 kΩ CMC 0,0014 % od 1,2 kΩ do 12 kΩ CMC 0,0013 % od 12 kΩ do 120 kΩ CMC 0,0014 % od 120 kΩ do 1,2 MΩ CMC 0,0033 % od 1,2 MΩ do 12 MΩ CMC 0,014 % od 12 MΩ do 120 MΩ CMC 0,083 % od 120 MΩ do 1,2 GΩ CMC 0,82 % Stejnosmerny odpor / zdroje a etalony stejnosmerneho odporu Kalibrace – elektricke veliciny Prime mereni multimetrem 0 Ω az 12 Ω CMC 0,002 % + 65 µΩ 12 Ω az 120 Ω CMC 0,0020 % 120 Ω az 1,2 kΩ CMC 0,0014 % 1,2 kΩ az 12 kΩ CMC 0,0013 % 12 kΩ az 120 kΩ CMC 0,0014 % 120 kΩ az 1,2 MΩ CMC 0,0033 % 1,2 MΩ az 12 MΩ CMC 0,014 % 12 MΩ az 120 MΩ CMC 0,083 % 120 MΩ az 1,2 GΩ CMC 0,82 % CP-003","search_en":"DC resistance / DC resistance sources and reference standards Calibration – electrical quantities Direct measurement using a multimeter 0 Ω to 12 Ω CMC 0,002 % + 65 µΩ 12 Ω to 120 Ω CMC 0,0020 % 120 Ω to 1,2 kΩ CMC 0,0014 % 1,2 kΩ to 12 kΩ CMC 0,0013 % 12 kΩ to 120 kΩ CMC 0,0014 % 120 kΩ to 1,2 MΩ CMC 0,0033 % 1,2 MΩ to 12 MΩ CMC 0,014 % 12 MΩ to 120 MΩ CMC 0,083 % 120 MΩ to 1,2 GΩ CMC 0,82 % CP-003","search_zh":"直流电阻 / 直流电阻源和标准器 校准 – 电学量 用万用表直接测量 0 Ω 至 12 Ω CMC 0,002 % + 65 µΩ 12 Ω 至 120 Ω CMC 0,0020 % 120 Ω 至 1,2 kΩ CMC 0,0014 % 1,2 kΩ 至 12 kΩ CMC 0,0013 % 12 kΩ 至 120 kΩ CMC 0,0014 % 120 kΩ 至 1,2 MΩ CMC 0,0033 % 1,2 MΩ 至 12 MΩ CMC 0,014 % 12 MΩ 至 120 MΩ CMC 0,083 % 120 MΩ 至 1,2 GΩ CMC 0,82 % CP-003","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8405b3aa49bd9a2a5846e371","lab_id":"6ade8b5dff06824761708157","country":"CZ","accr_number":"2430","accr_body":"ČIA","row_label":"6","test_object":"Rezystancja przy prądzie stałym / mierniki rezystancji","test_object_en":"DC resistance / DC resistance meters","test_object_zh":"直流电阻 / 直流电阻测量仪器","test_object_cs":"Stejnosměrný odpor / měřidla stejnosměrného odporu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"0 Ω","cmc":"80 µΩ"},{"name":"","range":"1 Ω","cmc":"0,009 %"},{"name":"","range":"1,9 Ω","cmc":"0,0098 %"},{"name":"","range":"10 Ω","cmc":"0,0022 %"},{"name":"","range":"19 Ω","cmc":"0,0021 %"},{"name":"","range":"100 Ω","cmc":"0,0011 %"},{"name":"","range":"190 Ω","cmc":"0,0011 %"},{"name":"","range":"1 kΩ","cmc":"0,0008 %"},{"name":"","range":"1,9 kΩ","cmc":"0,0008 %"},{"name":"","range":"10 kΩ","cmc":"0,0007 %"},{"name":"","range":"19 kΩ","cmc":"0,0007 %"},{"name":"","range":"100 kΩ","cmc":"0,0008 %"},{"name":"","range":"190 kΩ","cmc":"0,0095 %"},{"name":"","range":"1 MΩ","cmc":"0,0012 %"},{"name":"","range":"1,9 MΩ","cmc":"0,0017 %"},{"name":"","range":"10 MΩ","cmc":"0,0040 %"},{"name":"","range":"19 MΩ","cmc":"0,0047 %"},{"name":"","range":"100 MΩ","cmc":"0,011 %"}],"parameters_en":[{"name":"","range":"0 Ω","cmc":"80 µΩ"},{"name":"","range":"1 Ω","cmc":"0,009 %"},{"name":"","range":"1,9 Ω","cmc":"0,0098 %"},{"name":"","range":"10 Ω","cmc":"0,0022 %"},{"name":"","range":"19 Ω","cmc":"0,0021 %"},{"name":"","range":"100 Ω","cmc":"0,0011 %"},{"name":"","range":"190 Ω","cmc":"0,0011 %"},{"name":"","range":"1 kΩ","cmc":"0,0008 %"},{"name":"","range":"1,9 kΩ","cmc":"0,0008 %"},{"name":"","range":"10 kΩ","cmc":"0,0007 %"},{"name":"","range":"19 kΩ","cmc":"0,0007 %"},{"name":"","range":"100 kΩ","cmc":"0,0008 %"},{"name":"","range":"190 kΩ","cmc":"0,0095 %"},{"name":"","range":"1 MΩ","cmc":"0,0012 %"},{"name":"","range":"1,9 MΩ","cmc":"0,0017 %"},{"name":"","range":"10 MΩ","cmc":"0,0040 %"},{"name":"","range":"19 MΩ","cmc":"0,0047 %"},{"name":"","range":"100 MΩ","cmc":"0,011 %"}],"parameters_zh":[{"name":"","range":"0 Ω","cmc":"80 µΩ"},{"name":"","range":"1 Ω","cmc":"0,009 %"},{"name":"","range":"1,9 Ω","cmc":"0,0098 %"},{"name":"","range":"10 Ω","cmc":"0,0022 %"},{"name":"","range":"19 Ω","cmc":"0,0021 %"},{"name":"","range":"100 Ω","cmc":"0,0011 %"},{"name":"","range":"190 Ω","cmc":"0,0011 %"},{"name":"","range":"1 kΩ","cmc":"0,0008 %"},{"name":"","range":"1,9 kΩ","cmc":"0,0008 %"},{"name":"","range":"10 kΩ","cmc":"0,0007 %"},{"name":"","range":"19 kΩ","cmc":"0,0007 %"},{"name":"","range":"100 kΩ","cmc":"0,0008 %"},{"name":"","range":"190 kΩ","cmc":"0,0095 %"},{"name":"","range":"1 MΩ","cmc":"0,0012 %"},{"name":"","range":"1,9 MΩ","cmc":"0,0017 %"},{"name":"","range":"10 MΩ","cmc":"0,0040 %"},{"name":"","range":"19 MΩ","cmc":"0,0047 %"},{"name":"","range":"100 MΩ","cmc":"0,011 %"}],"parameters_cs":[{"name":"","range":"0 Ω","cmc":"80 µΩ"},{"name":"","range":"1 Ω","cmc":"0,009 %"},{"name":"","range":"1,9 Ω","cmc":"0,0098 %"},{"name":"","range":"10 Ω","cmc":"0,0022 %"},{"name":"","range":"19 Ω","cmc":"0,0021 %"},{"name":"","range":"100 Ω","cmc":"0,0011 %"},{"name":"","range":"190 Ω","cmc":"0,0011 %"},{"name":"","range":"1 kΩ","cmc":"0,0008 %"},{"name":"","range":"1,9 kΩ","cmc":"0,0008 %"},{"name":"","range":"10 kΩ","cmc":"0,0007 %"},{"name":"","range":"19 kΩ","cmc":"0,0007 %"},{"name":"","range":"100 kΩ","cmc":"0,0008 %"},{"name":"","range":"190 kΩ","cmc":"0,0095 %"},{"name":"","range":"1 MΩ","cmc":"0,0012 %"},{"name":"","range":"1,9 MΩ","cmc":"0,0017 %"},{"name":"","range":"10 MΩ","cmc":"0,0040 %"},{"name":"","range":"19 MΩ","cmc":"0,0047 %"},{"name":"","range":"100 MΩ","cmc":"0,011 %"}],"technique":"Generowanie kalibratorem","technique_en":"Generation using a calibrator","technique_zh":"用校准器产生","technique_cs":"Generování kalibrátorem","techniques":["Generowanie kalibratorem"],"techniques_en":["Generation using a calibrator"],"techniques_zh":["用校准器产生"],"techniques_cs":["Generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n0 Ω CMC 80 µΩ\n1 Ω CMC 0,009 %\n1,9 Ω CMC 0,0098 %\n10 Ω CMC 0,0022 %\n19 Ω CMC 0,0021 %\n100 Ω CMC 0,0011 %\n190 Ω CMC 0,0011 %\n1 kΩ CMC 0,0008 %\n1,9 kΩ CMC 0,0008 %\n10 kΩ CMC 0,0007 %\n19 kΩ CMC 0,0007 %\n100 kΩ CMC 0,0008 %\n190 kΩ CMC 0,0095 %\n1 MΩ CMC 0,0012 %\n1,9 MΩ CMC 0,0017 %\n10 MΩ CMC 0,0040 %\n19 MΩ CMC 0,0047 %\n100 MΩ CMC 0,011 %\nGenerowanie kalibratorem","reference":"CP-003","norm_bases":["CP-003"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / mierniki rezystancji Wzorcowanie – wielkości elektryczne Generowanie kalibratorem 0 Ω CMC 80 µΩ 1 Ω CMC 0,009 % 1,9 Ω CMC 0,0098 % 10 Ω CMC 0,0022 % 19 Ω CMC 0,0021 % 100 Ω CMC 0,0011 % 190 Ω CMC 0,0011 % 1 kΩ CMC 0,0008 % 1,9 kΩ CMC 0,0008 % 10 kΩ CMC 0,0007 % 19 kΩ CMC 0,0007 % 100 kΩ CMC 0,0008 % 190 kΩ CMC 0,0095 % 1 MΩ CMC 0,0012 % 1,9 MΩ CMC 0,0017 % 10 MΩ CMC 0,0040 % 19 MΩ CMC 0,0047 % 100 MΩ CMC 0,011 % Stejnosměrný odpor / měřidla stejnosměrného odporu Kalibrace – elektrické veličiny Generování kalibrátorem 0 Ω CMC 80 µΩ 1 Ω CMC 0,009 % 1,9 Ω CMC 0,0098 % 10 Ω CMC 0,0022 % 19 Ω CMC 0,0021 % 100 Ω CMC 0,0011 % 190 Ω CMC 0,0011 % 1 kΩ CMC 0,0008 % 1,9 kΩ CMC 0,0008 % 10 kΩ CMC 0,0007 % 19 kΩ CMC 0,0007 % 100 kΩ CMC 0,0008 % 190 kΩ CMC 0,0095 % 1 MΩ CMC 0,0012 % 1,9 MΩ CMC 0,0017 % 10 MΩ CMC 0,0040 % 19 MΩ CMC 0,0047 % 100 MΩ CMC 0,011 % CP-003 Rezystancja przy pradzie stalym / mierniki rezystancji Wzorcowanie – wielkosci elektryczne Generowanie kalibratorem 0 Ω CMC 80 µΩ 1 Ω CMC 0,009 % 1,9 Ω CMC 0,0098 % 10 Ω CMC 0,0022 % 19 Ω CMC 0,0021 % 100 Ω CMC 0,0011 % 190 Ω CMC 0,0011 % 1 kΩ CMC 0,0008 % 1,9 kΩ CMC 0,0008 % 10 kΩ CMC 0,0007 % 19 kΩ CMC 0,0007 % 100 kΩ CMC 0,0008 % 190 kΩ CMC 0,0095 % 1 MΩ CMC 0,0012 % 1,9 MΩ CMC 0,0017 % 10 MΩ CMC 0,0040 % 19 MΩ CMC 0,0047 % 100 MΩ CMC 0,011 % Stejnosmerny odpor / meridla stejnosmerneho odporu Kalibrace – elektricke veliciny Generovani kalibratorem 0 Ω CMC 80 µΩ 1 Ω CMC 0,009 % 1,9 Ω CMC 0,0098 % 10 Ω CMC 0,0022 % 19 Ω CMC 0,0021 % 100 Ω CMC 0,0011 % 190 Ω CMC 0,0011 % 1 kΩ CMC 0,0008 % 1,9 kΩ CMC 0,0008 % 10 kΩ CMC 0,0007 % 19 kΩ CMC 0,0007 % 100 kΩ CMC 0,0008 % 190 kΩ CMC 0,0095 % 1 MΩ CMC 0,0012 % 1,9 MΩ CMC 0,0017 % 10 MΩ CMC 0,0040 % 19 MΩ CMC 0,0047 % 100 MΩ CMC 0,011 % CP-003","search_en":"DC resistance / DC resistance meters Calibration – electrical quantities Generation using a calibrator 0 Ω CMC 80 µΩ 1 Ω CMC 0,009 % 1,9 Ω CMC 0,0098 % 10 Ω CMC 0,0022 % 19 Ω CMC 0,0021 % 100 Ω CMC 0,0011 % 190 Ω CMC 0,0011 % 1 kΩ CMC 0,0008 % 1,9 kΩ CMC 0,0008 % 10 kΩ CMC 0,0007 % 19 kΩ CMC 0,0007 % 100 kΩ CMC 0,0008 % 190 kΩ CMC 0,0095 % 1 MΩ CMC 0,0012 % 1,9 MΩ CMC 0,0017 % 10 MΩ CMC 0,0040 % 19 MΩ CMC 0,0047 % 100 MΩ CMC 0,011 % CP-003","search_zh":"直流电阻 / 直流电阻测量仪器 校准 – 电学量 用校准器产生 0 Ω CMC 80 µΩ 1 Ω CMC 0,009 % 1,9 Ω CMC 0,0098 % 10 Ω CMC 0,0022 % 19 Ω CMC 0,0021 % 100 Ω CMC 0,0011 % 190 Ω CMC 0,0011 % 1 kΩ CMC 0,0008 % 1,9 kΩ CMC 0,0008 % 10 kΩ CMC 0,0007 % 19 kΩ CMC 0,0007 % 100 kΩ CMC 0,0008 % 190 kΩ CMC 0,0095 % 1 MΩ CMC 0,0012 % 1,9 MΩ CMC 0,0017 % 10 MΩ CMC 0,0040 % 19 MΩ CMC 0,0047 % 100 MΩ CMC 0,011 % CP-003","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8e8cdec89aaa8a310f3a5d60","lab_id":"6ade8b5dff06824761708157","country":"CZ","accr_number":"2430","accr_body":"ČIA","row_label":"7","test_object":"Napięcie przemienne / źródła i wzorce napięcia przemiennego","test_object_en":"AC voltage / AC voltage sources and reference standards","test_object_zh":"交流电压 / 交流电压源和标准器","test_object_cs":"Střídavé napětí / zdroje a etalony střídavého napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"40 Hz do 1 kHz","range":"od 0,1 mV do 12 mV","cmc":"6,1 µV"},{"name":"40 Hz do 1 kHz","range":"od 12 mV do 120 mV","cmc":"12 µV"},{"name":"40 Hz do 1 kHz","range":"od 120 mV do 12 V","cmc":"0,026 %"},{"name":"1 kHz do 20 kHz","range":"od 120 mV do 12 V","cmc":"0,030 %"},{"name":"20 kHz do 50 kHz","range":"od 120 mV do 12 V","cmc":"0,043 %"},{"name":"50 kHz do 100 kHz","range":"od 120 mV do 12 V","cmc":"0,099 %"},{"name":"40 Hz do 20 kHz","range":"od 12 V do 120 V","cmc":"0,034 %"},{"name":"20 kHz do 50 kHz","range":"od 12 V do 120 V","cmc":"0,048 %"},{"name":"50 kHz do 100 kHz","range":"od 12 V do 120 V","cmc":"0,14 %"},{"name":"40 Hz do 20 kHz","range":"od 120 V do 700 V","cmc":"0,074 %"}],"parameters_en":[{"name":"40 Hz to 1 kHz","range":"0,1 mV to 12 mV","cmc":"6,1 µV"},{"name":"40 Hz to 1 kHz","range":"12 mV to 120 mV","cmc":"12 µV"},{"name":"40 Hz to 1 kHz","range":"120 mV to 12 V","cmc":"0,026 %"},{"name":"1 kHz to 20 kHz","range":"120 mV to 12 V","cmc":"0,030 %"},{"name":"20 kHz to 50 kHz","range":"120 mV to 12 V","cmc":"0,043 %"},{"name":"50 kHz to 100 kHz","range":"120 mV to 12 V","cmc":"0,099 %"},{"name":"40 Hz to 20 kHz","range":"12 V to 120 V","cmc":"0,034 %"},{"name":"20 kHz to 50 kHz","range":"12 V to 120 V","cmc":"0,048 %"},{"name":"50 kHz to 100 kHz","range":"12 V to 120 V","cmc":"0,14 %"},{"name":"40 Hz to 20 kHz","range":"120 V to 700 V","cmc":"0,074 %"}],"parameters_zh":[{"name":"40 Hz 至 1 kHz","range":"0,1 mV 至 12 mV","cmc":"6,1 µV"},{"name":"40 Hz 至 1 kHz","range":"12 mV 至 120 mV","cmc":"12 µV"},{"name":"40 Hz 至 1 kHz","range":"120 mV 至 12 V","cmc":"0,026 %"},{"name":"1 kHz 至 20 kHz","range":"120 mV 至 12 V","cmc":"0,030 %"},{"name":"20 kHz 至 50 kHz","range":"120 mV 至 12 V","cmc":"0,043 %"},{"name":"50 kHz 至 100 kHz","range":"120 mV 至 12 V","cmc":"0,099 %"},{"name":"40 Hz 至 20 kHz","range":"12 V 至 120 V","cmc":"0,034 %"},{"name":"20 kHz 至 50 kHz","range":"12 V 至 120 V","cmc":"0,048 %"},{"name":"50 kHz 至 100 kHz","range":"12 V 至 120 V","cmc":"0,14 %"},{"name":"40 Hz 至 20 kHz","range":"120 V 至 700 V","cmc":"0,074 %"}],"parameters_cs":[{"name":"40 Hz až 1 kHz","range":"0,1 mV až 12 mV","cmc":"6,1 µV"},{"name":"40 Hz až 1 kHz","range":"12 mV až 120 mV","cmc":"12 µV"},{"name":"40 Hz až 1 kHz","range":"120 mV až 12 V","cmc":"0,026 %"},{"name":"1 kHz až 20 kHz","range":"120 mV až 12 V","cmc":"0,030 %"},{"name":"20 kHz až 50 kHz","range":"120 mV až 12 V","cmc":"0,043 %"},{"name":"50 kHz až 100 kHz","range":"120 mV až 12 V","cmc":"0,099 %"},{"name":"40 Hz až 20 kHz","range":"12 V až 120 V","cmc":"0,034 %"},{"name":"20 kHz až 50 kHz","range":"12 V až 120 V","cmc":"0,048 %"},{"name":"50 kHz až 100 kHz","range":"12 V až 120 V","cmc":"0,14 %"},{"name":"40 Hz až 20 kHz","range":"120 V až 700 V","cmc":"0,074 %"}],"technique":"Pomiar bezpośredni multimetrem wzorcowym","technique_en":"Direct measurement by a reference multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Pomiar bezpośredni multimetrem wzorcowym"],"techniques_en":["Direct measurement by a reference multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n40 Hz do 1 kHz od 0,1 mV do 12 mV CMC 6,1 µV\n40 Hz do 1 kHz od 12 mV do 120 mV CMC 12 µV\n40 Hz do 1 kHz od 120 mV do 12 V CMC 0,026 %\n1 kHz do 20 kHz od 120 mV do 12 V CMC 0,030 %\n20 kHz do 50 kHz od 120 mV do 12 V CMC 0,043 %\n50 kHz do 100 kHz od 120 mV do 12 V CMC 0,099 %\n40 Hz do 20 kHz od 12 V do 120 V CMC 0,034 %\n20 kHz do 50 kHz od 12 V do 120 V CMC 0,048 %\n50 kHz do 100 kHz od 12 V do 120 V CMC 0,14 %\n40 Hz do 20 kHz od 120 V do 700 V CMC 0,074 %\nPomiar bezpośredni multimetrem wzorcowym","reference":"CP-004","norm_bases":["CP-004"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / źródła i wzorce napięcia przemiennego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem wzorcowym 40 Hz do 1 kHz od 0,1 mV do 12 mV CMC 6,1 µV 40 Hz do 1 kHz od 12 mV do 120 mV CMC 12 µV 40 Hz do 1 kHz od 120 mV do 12 V CMC 0,026 % 1 kHz do 20 kHz od 120 mV do 12 V CMC 0,030 % 20 kHz do 50 kHz od 120 mV do 12 V CMC 0,043 % 50 kHz do 100 kHz od 120 mV do 12 V CMC 0,099 % 40 Hz do 20 kHz od 12 V do 120 V CMC 0,034 % 20 kHz do 50 kHz od 12 V do 120 V CMC 0,048 % 50 kHz do 100 kHz od 12 V do 120 V CMC 0,14 % 40 Hz do 20 kHz od 120 V do 700 V CMC 0,074 % Střídavé napětí / zdroje a etalony střídavého napětí Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem 40 Hz až 1 kHz 0,1 mV až 12 mV CMC 6,1 µV 40 Hz až 1 kHz 12 mV až 120 mV CMC 12 µV 40 Hz až 1 kHz 120 mV až 12 V CMC 0,026 % 1 kHz až 20 kHz 120 mV až 12 V CMC 0,030 % 20 kHz až 50 kHz 120 mV až 12 V CMC 0,043 % 50 kHz až 100 kHz 120 mV až 12 V CMC 0,099 % 40 Hz až 20 kHz 12 V až 120 V CMC 0,034 % 20 kHz až 50 kHz 12 V až 120 V CMC 0,048 % 50 kHz až 100 kHz 12 V až 120 V CMC 0,14 % 40 Hz až 20 kHz 120 V až 700 V CMC 0,074 % CP-004 Napiecie przemienne / zrodla i wzorce napiecia przemiennego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem wzorcowym 40 Hz do 1 kHz od 0,1 mV do 12 mV CMC 6,1 µV 40 Hz do 1 kHz od 12 mV do 120 mV CMC 12 µV 40 Hz do 1 kHz od 120 mV do 12 V CMC 0,026 % 1 kHz do 20 kHz od 120 mV do 12 V CMC 0,030 % 20 kHz do 50 kHz od 120 mV do 12 V CMC 0,043 % 50 kHz do 100 kHz od 120 mV do 12 V CMC 0,099 % 40 Hz do 20 kHz od 12 V do 120 V CMC 0,034 % 20 kHz do 50 kHz od 12 V do 120 V CMC 0,048 % 50 kHz do 100 kHz od 12 V do 120 V CMC 0,14 % 40 Hz do 20 kHz od 120 V do 700 V CMC 0,074 % Stridave napeti / zdroje a etalony stridaveho napeti Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem 40 Hz az 1 kHz 0,1 mV az 12 mV CMC 6,1 µV 40 Hz az 1 kHz 12 mV az 120 mV CMC 12 µV 40 Hz az 1 kHz 120 mV az 12 V CMC 0,026 % 1 kHz az 20 kHz 120 mV az 12 V CMC 0,030 % 20 kHz az 50 kHz 120 mV az 12 V CMC 0,043 % 50 kHz az 100 kHz 120 mV az 12 V CMC 0,099 % 40 Hz az 20 kHz 12 V az 120 V CMC 0,034 % 20 kHz az 50 kHz 12 V az 120 V CMC 0,048 % 50 kHz az 100 kHz 12 V az 120 V CMC 0,14 % 40 Hz az 20 kHz 120 V az 700 V CMC 0,074 % CP-004","search_en":"AC voltage / AC voltage sources and reference standards Calibration – electrical quantities Direct measurement by a reference multimeter 40 Hz to 1 kHz 0,1 mV to 12 mV CMC 6,1 µV 40 Hz to 1 kHz 12 mV to 120 mV CMC 12 µV 40 Hz to 1 kHz 120 mV to 12 V CMC 0,026 % 1 kHz to 20 kHz 120 mV to 12 V CMC 0,030 % 20 kHz to 50 kHz 120 mV to 12 V CMC 0,043 % 50 kHz to 100 kHz 120 mV to 12 V CMC 0,099 % 40 Hz to 20 kHz 12 V to 120 V CMC 0,034 % 20 kHz to 50 kHz 12 V to 120 V CMC 0,048 % 50 kHz to 100 kHz 12 V to 120 V CMC 0,14 % 40 Hz to 20 kHz 120 V to 700 V CMC 0,074 % CP-004","search_zh":"交流电压 / 交流电压源和标准器 校准 – 电学量 用标准万用表直接测量 40 Hz 至 1 kHz 0,1 mV 至 12 mV CMC 6,1 µV 40 Hz 至 1 kHz 12 mV 至 120 mV CMC 12 µV 40 Hz 至 1 kHz 120 mV 至 12 V CMC 0,026 % 1 kHz 至 20 kHz 120 mV 至 12 V CMC 0,030 % 20 kHz 至 50 kHz 120 mV 至 12 V CMC 0,043 % 50 kHz 至 100 kHz 120 mV 至 12 V CMC 0,099 % 40 Hz 至 20 kHz 12 V 至 120 V CMC 0,034 % 20 kHz 至 50 kHz 12 V 至 120 V CMC 0,048 % 50 kHz 至 100 kHz 12 V 至 120 V CMC 0,14 % 40 Hz 至 20 kHz 120 V 至 700 V CMC 0,074 % CP-004","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"214b38c4bd3e4205bf0b9fe7","lab_id":"6ade8b5dff06824761708157","country":"CZ","accr_number":"2430","accr_body":"ČIA","row_label":"8","test_object":"Napięcie przemienne / mierniki napięcia przemiennego","test_object_en":"AC voltage / AC voltage meters","test_object_zh":"交流电压 / 交流电压测量仪器","test_object_cs":"Střídavé napětí / měřidla střídavého napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 20 Hz","range":"od 0,22 mV do 2,2 mV","cmc":"0,11 % + 4 µV"},{"name":"20 Hz do 40 Hz","range":"od 0,22 mV do 2,2 mV","cmc":"0,11 % + 4 µV"},{"name":"40 Hz do 20 kHz","range":"od 0,22 mV do 2,2 mV","cmc":"0,12 % + 4 µV"},{"name":"20 kHz do 50 kHz","range":"od 0,22 mV do 2,2 mV","cmc":"0,12 % + 4 µV"},{"name":"50 kHz do 100 kHz","range":"od 0,22 mV do 2,2 mV","cmc":"0,13 % + 5 µV"},{"name":"100 kHz do 300 kHz","range":"od 0,22 mV do 2,2 mV","cmc":"0,16 % + 10 µV"},{"name":"300 kHz do 500 kHz","range":"od 0,22 mV do 2,2 mV","cmc":"0,18 % + 20 µV"},{"name":"500 kHz do 1 MHz","range":"od 0,22 mV do 2,2 mV","cmc":"0,38 % + 20 µV"},{"name":"10 Hz do 20 Hz","range":"od 2,2 mV do 22 mV","cmc":"0,026 % + 4 µV"},{"name":"20 Hz do 40 Hz","range":"od 2,2 mV do 22 mV","cmc":"0,017 % + 4 µV"},{"name":"40 Hz do 20 kHz","range":"od 2,2 mV do 22 mV","cmc":"0,016 % + 4 µV"},{"name":"20 kHz do 50 kHz","range":"od 2,2 mV do 22 mV","cmc":"0,025 % + 4 µV"},{"name":"50 kHz do 100 kHz","range":"od 2,2 mV do 22 mV","cmc":"0,049 % + 5 µV"},{"name":"100 kHz do 300 kHz","range":"od 2,2 mV do 22 mV","cmc":"0,12 % + 10 µV"},{"name":"300 kHz do 500 kHz","range":"od 2,2 mV do 22 mV","cmc":"0,14 % + 20 µV"},{"name":"500 kHz do 1 MHz","range":"od 2,2 mV do 22 mV","cmc":"0,28 % + 20 µV"},{"name":"10 Hz do 20 Hz","range":"od 22 mV do 220 mV","cmc":"0,024 %"},{"name":"20 Hz do 40 Hz","range":"od 22 mV do 220 mV","cmc":"0,01 %"},{"name":"40 Hz do 20 kHz","range":"od 22 mV do 220 mV","cmc":"0,007 %"},{"name":"20 kHz do 50 kHz","range":"od 22 mV do 220 mV","cmc":"0,015 %"},{"name":"50 kHz do 100 kHz","range":"od 22 mV do 220 mV","cmc":"0,033 %"},{"name":"100 kHz do 300 kHz","range":"od 22 mV do 220 mV","cmc":"0,09 %"},{"name":"300 kHz do 500 kHz","range":"od 22 mV do 220 mV","cmc":"0,15 %"},{"name":"500 kHz do 1 MHz","range":"od 22 mV do 220 mV","cmc":"0,36 %"},{"name":"10 Hz do 20 Hz","range":"od 220 mV do 2,2 V","cmc":"0,024 %"},{"name":"20 Hz do 40 Hz","range":"od 220 mV do 2,2 V","cmc":"0,009 %"},{"name":"40 Hz do 20 kHz","range":"od 220 mV do 2,2 V","cmc":"0,005 %"},{"name":"20 kHz do 50 kHz","range":"od 220 mV do 2,2 V","cmc":"0,008 %"},{"name":"50 kHz do 100 kHz","range":"od 220 mV do 2,2 V","cmc":"0,019 %"},{"name":"100 kHz do 300 kHz","range":"od 220 mV do 2,2 V","cmc":"0,036 %"},{"name":"300 kHz do 500 kHz","range":"od 220 mV do 2,2 V","cmc":"0,095 %"},{"name":"500 kHz do 1 MHz","range":"od 220 mV do 2,2 V","cmc":"0,18 %"},{"name":"10 Hz do 20 Hz","range":"od 2,2 V do 22 V","cmc":"0,024 %"},{"name":"20 Hz do 40 Hz","range":"od 2,2 V do 22 V","cmc":"0,009 %"},{"name":"40 Hz do 20 kHz","range":"od 2,2 V do 22 V","cmc":"0,006 %"},{"name":"20 kHz do 50 kHz","range":"od 2,2 V do 22 V","cmc":"0,009 %"},{"name":"50 kHz do 100 kHz","range":"od 2,2 V do 22 V","cmc":"0,01 %"},{"name":"100 kHz do 300 kHz","range":"od 2,2 V do 22 V","cmc":"0,04 %"},{"name":"300 kHz do 500 kHz","range":"od 2,2 V do 22 V","cmc":"0,1 %"},{"name":"500 kHz do 1 MHz","range":"od 2,2 V do 22 V","cmc":"0,19 %"},{"name":"10 Hz do 20 Hz","range":"od 22 V do 220 V","cmc":"0,024 %"},{"name":"20 Hz do 40 Hz","range":"od 22 V do 220 V","cmc":"0,009 %"},{"name":"40 Hz do 20 kHz","range":"od 22 V do 220 V","cmc":"0,012 %"},{"name":"20 kHz do 50 kHz","range":"od 22 V do 220 V","cmc":"0,0083 %"},{"name":"50 kHz do 100 kHz","range":"od 22 V do 220 V","cmc":"0,018 %"},{"name":"50 Hz do 1 kHz","range":"od 220 V do 1000 V","cmc":"0,0078 %"}],"parameters_en":[{"name":"10 Hz to 20 Hz","range":"0,22 mV to 2,2 mV","cmc":"0,11 % + 4 µV"},{"name":"20 Hz to 40 Hz","range":"0,22 mV to 2,2 mV","cmc":"0,11 % + 4 µV"},{"name":"40 Hz to 20 kHz","range":"0,22 mV to 2,2 mV","cmc":"0,12 % + 4 µV"},{"name":"20 kHz to 50 kHz","range":"0,22 mV to 2,2 mV","cmc":"0,12 % + 4 µV"},{"name":"50 kHz to 100 kHz","range":"0,22 mV to 2,2 mV","cmc":"0,13 % + 5 µV"},{"name":"100 kHz to 300 kHz","range":"0,22 mV to 2,2 mV","cmc":"0,16 % + 10 µV"},{"name":"300 kHz to 500 kHz","range":"0,22 mV to 2,2 mV","cmc":"0,18 % + 20 µV"},{"name":"500 kHz to 1 MHz","range":"0,22 mV to 2,2 mV","cmc":"0,38 % + 20 µV"},{"name":"10 Hz to 20 Hz","range":"2,2 mV to 22 mV","cmc":"0,026 % + 4 µV"},{"name":"20 Hz to 40 Hz","range":"2,2 mV to 22 mV","cmc":"0,017 % + 4 µV"},{"name":"40 Hz to 20 kHz","range":"2,2 mV to 22 mV","cmc":"0,016 % + 4 µV"},{"name":"20 kHz to 50 kHz","range":"2,2 mV to 22 mV","cmc":"0,025 % + 4 µV"},{"name":"50 kHz to 100 kHz","range":"2,2 mV to 22 mV","cmc":"0,049 % + 5 µV"},{"name":"100 kHz to 300 kHz","range":"2,2 mV to 22 mV","cmc":"0,12 % + 10 µV"},{"name":"300 kHz to 500 kHz","range":"2,2 mV to 22 mV","cmc":"0,14 % + 20 µV"},{"name":"500 kHz to 1 MHz","range":"2,2 mV to 22 mV","cmc":"0,28 % + 20 µV"},{"name":"10 Hz to 20 Hz","range":"22 mV to 220 mV","cmc":"0,024 %"},{"name":"20 Hz to 40 Hz","range":"22 mV to 220 mV","cmc":"0,01 %"},{"name":"40 Hz to 20 kHz","range":"22 mV to 220 mV","cmc":"0,007 %"},{"name":"20 kHz to 50 kHz","range":"22 mV to 220 mV","cmc":"0,015 %"},{"name":"50 kHz to 100 kHz","range":"22 mV to 220 mV","cmc":"0,033 %"},{"name":"100 kHz to 300 kHz","range":"22 mV to 220 mV","cmc":"0,09 %"},{"name":"300 kHz to 500 kHz","range":"22 mV to 220 mV","cmc":"0,15 %"},{"name":"500 kHz to 1 MHz","range":"22 mV to 220 mV","cmc":"0,36 %"},{"name":"10 Hz to 20 Hz","range":"220 mV to 2,2 V","cmc":"0,024 %"},{"name":"20 Hz to 40 Hz","range":"220 mV to 2,2 V","cmc":"0,009 %"},{"name":"40 Hz to 20 kHz","range":"220 mV to 2,2 V","cmc":"0,005 %"},{"name":"20 kHz to 50 kHz","range":"220 mV to 2,2 V","cmc":"0,008 %"},{"name":"50 kHz to 100 kHz","range":"220 mV to 2,2 V","cmc":"0,019 %"},{"name":"100 kHz to 300 kHz","range":"220 mV to 2,2 V","cmc":"0,036 %"},{"name":"300 kHz to 500 kHz","range":"220 mV to 2,2 V","cmc":"0,095 %"},{"name":"500 kHz to 1 MHz","range":"220 mV to 2,2 V","cmc":"0,18 %"},{"name":"10 Hz to 20 Hz","range":"2,2 V to 22 V","cmc":"0,024 %"},{"name":"20 Hz to 40 Hz","range":"2,2 V to 22 V","cmc":"0,009 %"},{"name":"40 Hz to 20 kHz","range":"2,2 V to 22 V","cmc":"0,006 %"},{"name":"20 kHz to 50 kHz","range":"2,2 V to 22 V","cmc":"0,009 %"},{"name":"50 kHz to 100 kHz","range":"2,2 V to 22 V","cmc":"0,01 %"},{"name":"100 kHz to 300 kHz","range":"2,2 V to 22 V","cmc":"0,04 %"},{"name":"300 kHz to 500 kHz","range":"2,2 V to 22 V","cmc":"0,1 %"},{"name":"500 kHz to 1 MHz","range":"2,2 V to 22 V","cmc":"0,19 %"},{"name":"10 Hz to 20 Hz","range":"22 V to 220 V","cmc":"0,024 %"},{"name":"20 Hz to 40 Hz","range":"22 V to 220 V","cmc":"0,009 %"},{"name":"40 Hz to 20 kHz","range":"22 V to 220 V","cmc":"0,012 %"},{"name":"20 kHz to 50 kHz","range":"22 V to 220 V","cmc":"0,0083 %"},{"name":"50 kHz to 100 kHz","range":"22 V to 220 V","cmc":"0,018 %"},{"name":"50 Hz to 1 kHz","range":"220 V to 1000 V","cmc":"0,0078 %"}],"parameters_zh":[{"name":"10 Hz 至 20 Hz","range":"0,22 mV 至 2,2 mV","cmc":"0,11 % + 4 µV"},{"name":"20 Hz 至 40 Hz","range":"0,22 mV 至 2,2 mV","cmc":"0,11 % + 4 µV"},{"name":"40 Hz 至 20 kHz","range":"0,22 mV 至 2,2 mV","cmc":"0,12 % + 4 µV"},{"name":"20 kHz 至 50 kHz","range":"0,22 mV 至 2,2 mV","cmc":"0,12 % + 4 µV"},{"name":"50 kHz 至 100 kHz","range":"0,22 mV 至 2,2 mV","cmc":"0,13 % + 5 µV"},{"name":"100 kHz 至 300 kHz","range":"0,22 mV 至 2,2 mV","cmc":"0,16 % + 10 µV"},{"name":"300 kHz 至 500 kHz","range":"0,22 mV 至 2,2 mV","cmc":"0,18 % + 20 µV"},{"name":"500 kHz 至 1 MHz","range":"0,22 mV 至 2,2 mV","cmc":"0,38 % + 20 µV"},{"name":"10 Hz 至 20 Hz","range":"2,2 mV 至 22 mV","cmc":"0,026 % + 4 µV"},{"name":"20 Hz 至 40 Hz","range":"2,2 mV 至 22 mV","cmc":"0,017 % + 4 µV"},{"name":"40 Hz 至 20 kHz","range":"2,2 mV 至 22 mV","cmc":"0,016 % + 4 µV"},{"name":"20 kHz 至 50 kHz","range":"2,2 mV 至 22 mV","cmc":"0,025 % + 4 µV"},{"name":"50 kHz 至 100 kHz","range":"2,2 mV 至 22 mV","cmc":"0,049 % + 5 µV"},{"name":"100 kHz 至 300 kHz","range":"2,2 mV 至 22 mV","cmc":"0,12 % + 10 µV"},{"name":"300 kHz 至 500 kHz","range":"2,2 mV 至 22 mV","cmc":"0,14 % + 20 µV"},{"name":"500 kHz 至 1 MHz","range":"2,2 mV 至 22 mV","cmc":"0,28 % + 20 µV"},{"name":"10 Hz 至 20 Hz","range":"22 mV 至 220 mV","cmc":"0,024 %"},{"name":"20 Hz 至 40 Hz","range":"22 mV 至 220 mV","cmc":"0,01 %"},{"name":"40 Hz 至 20 kHz","range":"22 mV 至 220 mV","cmc":"0,007 %"},{"name":"20 kHz 至 50 kHz","range":"22 mV 至 220 mV","cmc":"0,015 %"},{"name":"50 kHz 至 100 kHz","range":"22 mV 至 220 mV","cmc":"0,033 %"},{"name":"100 kHz 至 300 kHz","range":"22 mV 至 220 mV","cmc":"0,09 %"},{"name":"300 kHz 至 500 kHz","range":"22 mV 至 220 mV","cmc":"0,15 %"},{"name":"500 kHz 至 1 MHz","range":"22 mV 至 220 mV","cmc":"0,36 %"},{"name":"10 Hz 至 20 Hz","range":"220 mV 至 2,2 V","cmc":"0,024 %"},{"name":"20 Hz 至 40 Hz","range":"220 mV 至 2,2 V","cmc":"0,009 %"},{"name":"40 Hz 至 20 kHz","range":"220 mV 至 2,2 V","cmc":"0,005 %"},{"name":"20 kHz 至 50 kHz","range":"220 mV 至 2,2 V","cmc":"0,008 %"},{"name":"50 kHz 至 100 kHz","range":"220 mV 至 2,2 V","cmc":"0,019 %"},{"name":"100 kHz 至 300 kHz","range":"220 mV 至 2,2 V","cmc":"0,036 %"},{"name":"300 kHz 至 500 kHz","range":"220 mV 至 2,2 V","cmc":"0,095 %"},{"name":"500 kHz 至 1 MHz","range":"220 mV 至 2,2 V","cmc":"0,18 %"},{"name":"10 Hz 至 20 Hz","range":"2,2 V 至 22 V","cmc":"0,024 %"},{"name":"20 Hz 至 40 Hz","range":"2,2 V 至 22 V","cmc":"0,009 %"},{"name":"40 Hz 至 20 kHz","range":"2,2 V 至 22 V","cmc":"0,006 %"},{"name":"20 kHz 至 50 kHz","range":"2,2 V 至 22 V","cmc":"0,009 %"},{"name":"50 kHz 至 100 kHz","range":"2,2 V 至 22 V","cmc":"0,01 %"},{"name":"100 kHz 至 300 kHz","range":"2,2 V 至 22 V","cmc":"0,04 %"},{"name":"300 kHz 至 500 kHz","range":"2,2 V 至 22 V","cmc":"0,1 %"},{"name":"500 kHz 至 1 MHz","range":"2,2 V 至 22 V","cmc":"0,19 %"},{"name":"10 Hz 至 20 Hz","range":"22 V 至 220 V","cmc":"0,024 %"},{"name":"20 Hz 至 40 Hz","range":"22 V 至 220 V","cmc":"0,009 %"},{"name":"40 Hz 至 20 kHz","range":"22 V 至 220 V","cmc":"0,012 %"},{"name":"20 kHz 至 50 kHz","range":"22 V 至 220 V","cmc":"0,0083 %"},{"name":"50 kHz 至 100 kHz","range":"22 V 至 220 V","cmc":"0,018 %"},{"name":"50 Hz 至 1 kHz","range":"220 V 至 1000 V","cmc":"0,0078 %"}],"parameters_cs":[{"name":"10 Hz až 20 Hz","range":"0,22 mV až 2,2 mV","cmc":"0,11 % + 4 µV"},{"name":"20 Hz až 40 Hz","range":"0,22 mV až 2,2 mV","cmc":"0,11 % + 4 µV"},{"name":"40 Hz až 20 kHz","range":"0,22 mV až 2,2 mV","cmc":"0,12 % + 4 µV"},{"name":"20 kHz až 50 kHz","range":"0,22 mV až 2,2 mV","cmc":"0,12 % + 4 µV"},{"name":"50 kHz až 100 kHz","range":"0,22 mV až 2,2 mV","cmc":"0,13 % + 5 µV"},{"name":"100 kHz až 300 kHz","range":"0,22 mV až 2,2 mV","cmc":"0,16 % + 10 µV"},{"name":"300 kHz až 500 kHz","range":"0,22 mV až 2,2 mV","cmc":"0,18 % + 20 µV"},{"name":"500 kHz až 1 MHz","range":"0,22 mV až 2,2 mV","cmc":"0,38 % + 20 µV"},{"name":"10 Hz až 20 Hz","range":"2,2 mV až 22 mV","cmc":"0,026 % + 4 µV"},{"name":"20 Hz až 40 Hz","range":"2,2 mV až 22 mV","cmc":"0,017 % + 4 µV"},{"name":"40 Hz až 20 kHz","range":"2,2 mV až 22 mV","cmc":"0,016 % + 4 µV"},{"name":"20 kHz až 50 kHz","range":"2,2 mV až 22 mV","cmc":"0,025 % + 4 µV"},{"name":"50 kHz až 100 kHz","range":"2,2 mV až 22 mV","cmc":"0,049 % + 5 µV"},{"name":"100 kHz až 300 kHz","range":"2,2 mV až 22 mV","cmc":"0,12 % + 10 µV"},{"name":"300 kHz až 500 kHz","range":"2,2 mV až 22 mV","cmc":"0,14 % + 20 µV"},{"name":"500 kHz až 1 MHz","range":"2,2 mV až 22 mV","cmc":"0,28 % + 20 µV"},{"name":"10 Hz až 20 Hz","range":"22 mV až 220 mV","cmc":"0,024 %"},{"name":"20 Hz až 40 Hz","range":"22 mV až 220 mV","cmc":"0,01 %"},{"name":"40 Hz až 20 kHz","range":"22 mV až 220 mV","cmc":"0,007 %"},{"name":"20 kHz až 50 kHz","range":"22 mV až 220 mV","cmc":"0,015 %"},{"name":"50 kHz až 100 kHz","range":"22 mV až 220 mV","cmc":"0,033 %"},{"name":"100 kHz až 300 kHz","range":"22 mV až 220 mV","cmc":"0,09 %"},{"name":"300 kHz až 500 kHz","range":"22 mV až 220 mV","cmc":"0,15 %"},{"name":"500 kHz až 1 MHz","range":"22 mV až 220 mV","cmc":"0,36 %"},{"name":"10 Hz až 20 Hz","range":"220 mV až 2,2 V","cmc":"0,024 %"},{"name":"20 Hz až 40 Hz","range":"220 mV až 2,2 V","cmc":"0,009 %"},{"name":"40 Hz až 20 kHz","range":"220 mV až 2,2 V","cmc":"0,005 %"},{"name":"20 kHz až 50 kHz","range":"220 mV až 2,2 V","cmc":"0,008 %"},{"name":"50 kHz až 100 kHz","range":"220 mV až 2,2 V","cmc":"0,019 %"},{"name":"100 kHz až 300 kHz","range":"220 mV až 2,2 V","cmc":"0,036 %"},{"name":"300 kHz až 500 kHz","range":"220 mV až 2,2 V","cmc":"0,095 %"},{"name":"500 kHz až 1 MHz","range":"220 mV až 2,2 V","cmc":"0,18 %"},{"name":"10 Hz až 20 Hz","range":"2,2 V až 22 V","cmc":"0,024 %"},{"name":"20 Hz až 40 Hz","range":"2,2 V až 22 V","cmc":"0,009 %"},{"name":"40 Hz až 20 kHz","range":"2,2 V až 22 V","cmc":"0,006 %"},{"name":"20 kHz až 50 kHz","range":"2,2 V až 22 V","cmc":"0,009 %"},{"name":"50 kHz až 100 kHz","range":"2,2 V až 22 V","cmc":"0,01 %"},{"name":"100 kHz až 300 kHz","range":"2,2 V až 22 V","cmc":"0,04 %"},{"name":"300 kHz až 500 kHz","range":"2,2 V až 22 V","cmc":"0,1 %"},{"name":"500 kHz až 1 MHz","range":"2,2 V až 22 V","cmc":"0,19 %"},{"name":"10 Hz až 20 Hz","range":"22 V až 220 V","cmc":"0,024 %"},{"name":"20 Hz až 40 Hz","range":"22 V až 220 V","cmc":"0,009 %"},{"name":"40 Hz až 20 kHz","range":"22 V až 220 V","cmc":"0,012 %"},{"name":"20 kHz až 50 kHz","range":"22 V až 220 V","cmc":"0,0083 %"},{"name":"50 kHz až 100 kHz","range":"22 V až 220 V","cmc":"0,018 %"},{"name":"50 Hz až 1 kHz","range":"220 V až 1000 V","cmc":"0,0078 %"}],"technique":"Generowanie kalibratorem","technique_en":"Generation using a calibrator","technique_zh":"用校准器产生","technique_cs":"Generování kalibrátorem","techniques":["Generowanie kalibratorem"],"techniques_en":["Generation using a calibrator"],"techniques_zh":["用校准器产生"],"techniques_cs":["Generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 20 Hz od 0,22 mV do 2,2 mV CMC 0,11 % + 4 µV\n20 Hz do 40 Hz od 0,22 mV do 2,2 mV CMC 0,11 % + 4 µV\n40 Hz do 20 kHz od 0,22 mV do 2,2 mV CMC 0,12 % + 4 µV\n20 kHz do 50 kHz od 0,22 mV do 2,2 mV CMC 0,12 % + 4 µV\n50 kHz do 100 kHz od 0,22 mV do 2,2 mV CMC 0,13 % + 5 µV\n100 kHz do 300 kHz od 0,22 mV do 2,2 mV CMC 0,16 % + 10 µV\n300 kHz do 500 kHz od 0,22 mV do 2,2 mV CMC 0,18 % + 20 µV\n500 kHz do 1 MHz od 0,22 mV do 2,2 mV CMC 0,38 % + 20 µV\n10 Hz do 20 Hz od 2,2 mV do 22 mV CMC 0,026 % + 4 µV\n20 Hz do 40 Hz od 2,2 mV do 22 mV CMC 0,017 % + 4 µV\n40 Hz do 20 kHz od 2,2 mV do 22 mV CMC 0,016 % + 4 µV\n20 kHz do 50 kHz od 2,2 mV do 22 mV CMC 0,025 % + 4 µV\n50 kHz do 100 kHz od 2,2 mV do 22 mV CMC 0,049 % + 5 µV\n100 kHz do 300 kHz od 2,2 mV do 22 mV CMC 0,12 % + 10 µV\n300 kHz do 500 kHz od 2,2 mV do 22 mV CMC 0,14 % + 20 µV\n500 kHz do 1 MHz od 2,2 mV do 22 mV CMC 0,28 % + 20 µV\n10 Hz do 20 Hz od 22 mV do 220 mV CMC 0,024 %\n20 Hz do 40 Hz od 22 mV do 220 mV CMC 0,01 %\n40 Hz do 20 kHz od 22 mV do 220 mV CMC 0,007 %\n20 kHz do 50 kHz od 22 mV do 220 mV CMC 0,015 %\n50 kHz do 100 kHz od 22 mV do 220 mV CMC 0,033 %\n100 kHz do 300 kHz od 22 mV do 220 mV CMC 0,09 %\n300 kHz do 500 kHz od 22 mV do 220 mV CMC 0,15 %\n500 kHz do 1 MHz od 22 mV do 220 mV CMC 0,36 %\n10 Hz do 20 Hz od 220 mV do 2,2 V CMC 0,024 %\n20 Hz do 40 Hz od 220 mV do 2,2 V CMC 0,009 %\n40 Hz do 20 kHz od 220 mV do 2,2 V CMC 0,005 %\n20 kHz do 50 kHz od 220 mV do 2,2 V CMC 0,008 %\n50 kHz do 100 kHz od 220 mV do 2,2 V CMC 0,019 %\n100 kHz do 300 kHz od 220 mV do 2,2 V CMC 0,036 %\n300 kHz do 500 kHz od 220 mV do 2,2 V CMC 0,095 %\n500 kHz do 1 MHz od 220 mV do 2,2 V CMC 0,18 %\n10 Hz do 20 Hz od 2,2 V do 22 V CMC 0,024 %\n20 Hz do 40 Hz od 2,2 V do 22 V CMC 0,009 %\n40 Hz do 20 kHz od 2,2 V do 22 V CMC 0,006 %\n20 kHz do 50 kHz od 2,2 V do 22 V CMC 0,009 %\n50 kHz do 100 kHz od 2,2 V do 22 V CMC 0,01 %\n100 kHz do 300 kHz od 2,2 V do 22 V CMC 0,04 %\n300 kHz do 500 kHz od 2,2 V do 22 V CMC 0,1 %\n500 kHz do 1 MHz od 2,2 V do 22 V CMC 0,19 %\n10 Hz do 20 Hz od 22 V do 220 V CMC 0,024 %\n20 Hz do 40 Hz od 22 V do 220 V CMC 0,009 %\n40 Hz do 20 kHz od 22 V do 220 V CMC 0,012 %\n20 kHz do 50 kHz od 22 V do 220 V CMC 0,0083 %\n50 kHz do 100 kHz od 22 V do 220 V CMC 0,018 %\n50 Hz do 1 kHz od 220 V do 1000 V CMC 0,0078 %\nGenerowanie kalibratorem","reference":"CP-004","norm_bases":["CP-004"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / mierniki napięcia przemiennego Wzorcowanie – wielkości elektryczne Generowanie kalibratorem 10 Hz do 20 Hz od 0,22 mV do 2,2 mV CMC 0,11 % + 4 µV 20 Hz do 40 Hz od 0,22 mV do 2,2 mV CMC 0,11 % + 4 µV 40 Hz do 20 kHz od 0,22 mV do 2,2 mV CMC 0,12 % + 4 µV 20 kHz do 50 kHz od 0,22 mV do 2,2 mV CMC 0,12 % + 4 µV 50 kHz do 100 kHz od 0,22 mV do 2,2 mV CMC 0,13 % + 5 µV 100 kHz do 300 kHz od 0,22 mV do 2,2 mV CMC 0,16 % + 10 µV 300 kHz do 500 kHz od 0,22 mV do 2,2 mV CMC 0,18 % + 20 µV 500 kHz do 1 MHz od 0,22 mV do 2,2 mV CMC 0,38 % + 20 µV 10 Hz do 20 Hz od 2,2 mV do 22 mV CMC 0,026 % + 4 µV 20 Hz do 40 Hz od 2,2 mV do 22 mV CMC 0,017 % + 4 µV 40 Hz do 20 kHz od 2,2 mV do 22 mV CMC 0,016 % + 4 µV 20 kHz do 50 kHz od 2,2 mV do 22 mV CMC 0,025 % + 4 µV 50 kHz do 100 kHz od 2,2 mV do 22 mV CMC 0,049 % + 5 µV 100 kHz do 300 kHz od 2,2 mV do 22 mV CMC 0,12 % + 10 µV 300 kHz do 500 kHz od 2,2 mV do 22 mV CMC 0,14 % + 20 µV 500 kHz do 1 MHz od 2,2 mV do 22 mV CMC 0,28 % + 20 µV 10 Hz do 20 Hz od 22 mV do 220 mV CMC 0,024 % 20 Hz do 40 Hz od 22 mV do 220 mV CMC 0,01 % 40 Hz do 20 kHz od 22 mV do 220 mV CMC 0,007 % 20 kHz do 50 kHz od 22 mV do 220 mV CMC 0,015 % 50 kHz do 100 kHz od 22 mV do 220 mV CMC 0,033 % 100 kHz do 300 kHz od 22 mV do 220 mV CMC 0,09 % 300 kHz do 500 kHz od 22 mV do 220 mV CMC 0,15 % 500 kHz do 1 MHz od 22 mV do 220 mV CMC 0,36 % 10 Hz do 20 Hz od 220 mV do 2,2 V CMC 0,024 % 20 Hz do 40 Hz od 220 mV do 2,2 V CMC 0,009 % 40 Hz do 20 kHz od 220 mV do 2,2 V CMC 0,005 % 20 kHz do 50 kHz od 220 mV do 2,2 V CMC 0,008 % 50 kHz do 100 kHz od 220 mV do 2,2 V CMC 0,019 % 100 kHz do 300 kHz od 220 mV do 2,2 V CMC 0,036 % 300 kHz do 500 kHz od 220 mV do 2,2 V CMC 0,095 % 500 kHz do 1 MHz od 220 mV do 2,2 V CMC 0,18 % 10 Hz do 20 Hz od 2,2 V do 22 V CMC 0,024 % 20 Hz do 40 Hz od 2,2 V do 22 V CMC 0,009 % 40 Hz do 20 kHz od 2,2 V do 22 V CMC 0,006 % 20 kHz do 50 kHz od 2,2 V do 22 V CMC 0,009 % 50 kHz do 100 kHz od 2,2 V do 22 V CMC 0,01 % 100 kHz do 300 kHz od 2,2 V do 22 V CMC 0,04 % 300 kHz do 500 kHz od 2,2 V do 22 V CMC 0,1 % 500 kHz do 1 MHz od 2,2 V do 22 V CMC 0,19 % 10 Hz do 20 Hz od 22 V do 220 V CMC 0,024 % 20 Hz do 40 Hz od 22 V do 220 V CMC 0,009 % 40 Hz do 20 kHz od 22 V do 220 V CMC 0,012 % 20 kHz do 50 kHz od 22 V do 220 V CMC 0,0083 % 50 kHz do 100 kHz od 22 V do 220 V CMC 0,018 % 50 Hz do 1 kHz od 220 V do 1000 V CMC 0,0078 % Střídavé napětí / měřidla střídavého napětí Kalibrace – elektrické veličiny Generování kalibrátorem 10 Hz až 20 Hz 0,22 mV až 2,2 mV CMC 0,11 % + 4 µV 20 Hz až 40 Hz 0,22 mV až 2,2 mV CMC 0,11 % + 4 µV 40 Hz až 20 kHz 0,22 mV až 2,2 mV CMC 0,12 % + 4 µV 20 kHz až 50 kHz 0,22 mV až 2,2 mV CMC 0,12 % + 4 µV 50 kHz až 100 kHz 0,22 mV až 2,2 mV CMC 0,13 % + 5 µV 100 kHz až 300 kHz 0,22 mV až 2,2 mV CMC 0,16 % + 10 µV 300 kHz až 500 kHz 0,22 mV až 2,2 mV CMC 0,18 % + 20 µV 500 kHz až 1 MHz 0,22 mV až 2,2 mV CMC 0,38 % + 20 µV 10 Hz až 20 Hz 2,2 mV až 22 mV CMC 0,026 % + 4 µV 20 Hz až 40 Hz 2,2 mV až 22 mV CMC 0,017 % + 4 µV 40 Hz až 20 kHz 2,2 mV až 22 mV CMC 0,016 % + 4 µV 20 kHz až 50 kHz 2,2 mV až 22 mV CMC 0,025 % + 4 µV 50 kHz až 100 kHz 2,2 mV až 22 mV CMC 0,049 % + 5 µV 100 kHz až 300 kHz 2,2 mV až 22 mV CMC 0,12 % + 10 µV 300 kHz až 500 kHz 2,2 mV až 22 mV CMC 0,14 % + 20 µV 500 kHz až 1 MHz 2,2 mV až 22 mV CMC 0,28 % + 20 µV 10 Hz až 20 Hz 22 mV až 220 mV CMC 0,024 % 20 Hz až 40 Hz 22 mV až 220 mV CMC 0,01 % 40 Hz až 20 kHz 22 mV až 220 mV CMC 0,007 % 20 kHz až 50 kHz 22 mV až 220 mV CMC 0,015 % 50 kHz až 100 kHz 22 mV až 220 mV CMC 0,033 % 100 kHz až 300 kHz 22 mV až 220 mV CMC 0,09 % 300 kHz až 500 kHz 22 mV až 220 mV CMC 0,15 % 500 kHz až 1 MHz 22 mV až 220 mV CMC 0,36 % 10 Hz až 20 Hz 220 mV až 2,2 V CMC 0,024 % 20 Hz až 40 Hz 220 mV až 2,2 V CMC 0,009 % 40 Hz až 20 kHz 220 mV až 2,2 V CMC 0,005 % 20 kHz až 50 kHz 220 mV až 2,2 V CMC 0,008 % 50 kHz až 100 kHz 220 mV až 2,2 V CMC 0,019 % 100 kHz až 300 kHz 220 mV až 2,2 V CMC 0,036 % 300 kHz až 500 kHz 220 mV až 2,2 V CMC 0,095 % 500 kHz až 1 MHz 220 mV až 2,2 V CMC 0,18 % 10 Hz až 20 Hz 2,2 V až 22 V CMC 0,024 % 20 Hz až 40 Hz 2,2 V až 22 V CMC 0,009 % 40 Hz až 20 kHz 2,2 V až 22 V CMC 0,006 % 20 kHz až 50 kHz 2,2 V až 22 V CMC 0,009 % 50 kHz až 100 kHz 2,2 V až 22 V CMC 0,01 % 100 kHz až 300 kHz 2,2 V až 22 V CMC 0,04 % 300 kHz až 500 kHz 2,2 V až 22 V CMC 0,1 % 500 kHz až 1 MHz 2,2 V až 22 V CMC 0,19 % 10 Hz až 20 Hz 22 V až 220 V CMC 0,024 % 20 Hz až 40 Hz 22 V až 220 V CMC 0,009 % 40 Hz až 20 kHz 22 V až 220 V CMC 0,012 % 20 kHz až 50 kHz 22 V až 220 V CMC 0,0083 % 50 kHz až 100 kHz 22 V až 220 V CMC 0,018 % 50 Hz až 1 kHz 220 V až 1000 V CMC 0,0078 % CP-004 Napiecie przemienne / mierniki napiecia przemiennego Wzorcowanie – wielkosci elektryczne Generowanie kalibratorem 10 Hz do 20 Hz od 0,22 mV do 2,2 mV CMC 0,11 % + 4 µV 20 Hz do 40 Hz od 0,22 mV do 2,2 mV CMC 0,11 % + 4 µV 40 Hz do 20 kHz od 0,22 mV do 2,2 mV CMC 0,12 % + 4 µV 20 kHz do 50 kHz od 0,22 mV do 2,2 mV CMC 0,12 % + 4 µV 50 kHz do 100 kHz od 0,22 mV do 2,2 mV CMC 0,13 % + 5 µV 100 kHz do 300 kHz od 0,22 mV do 2,2 mV CMC 0,16 % + 10 µV 300 kHz do 500 kHz od 0,22 mV do 2,2 mV CMC 0,18 % + 20 µV 500 kHz do 1 MHz od 0,22 mV do 2,2 mV CMC 0,38 % + 20 µV 10 Hz do 20 Hz od 2,2 mV do 22 mV CMC 0,026 % + 4 µV 20 Hz do 40 Hz od 2,2 mV do 22 mV CMC 0,017 % + 4 µV 40 Hz do 20 kHz od 2,2 mV do 22 mV CMC 0,016 % + 4 µV 20 kHz do 50 kHz od 2,2 mV do 22 mV CMC 0,025 % + 4 µV 50 kHz do 100 kHz od 2,2 mV do 22 mV CMC 0,049 % + 5 µV 100 kHz do 300 kHz od 2,2 mV do 22 mV CMC 0,12 % + 10 µV 300 kHz do 500 kHz od 2,2 mV do 22 mV CMC 0,14 % + 20 µV 500 kHz do 1 MHz od 2,2 mV do 22 mV CMC 0,28 % + 20 µV 10 Hz do 20 Hz od 22 mV do 220 mV CMC 0,024 % 20 Hz do 40 Hz od 22 mV do 220 mV CMC 0,01 % 40 Hz do 20 kHz od 22 mV do 220 mV CMC 0,007 % 20 kHz do 50 kHz od 22 mV do 220 mV CMC 0,015 % 50 kHz do 100 kHz od 22 mV do 220 mV CMC 0,033 % 100 kHz do 300 kHz od 22 mV do 220 mV CMC 0,09 % 300 kHz do 500 kHz od 22 mV do 220 mV CMC 0,15 % 500 kHz do 1 MHz od 22 mV do 220 mV CMC 0,36 % 10 Hz do 20 Hz od 220 mV do 2,2 V CMC 0,024 % 20 Hz do 40 Hz od 220 mV do 2,2 V CMC 0,009 % 40 Hz do 20 kHz od 220 mV do 2,2 V CMC 0,005 % 20 kHz do 50 kHz od 220 mV do 2,2 V CMC 0,008 % 50 kHz do 100 kHz od 220 mV do 2,2 V CMC 0,019 % 100 kHz do 300 kHz od 220 mV do 2,2 V CMC 0,036 % 300 kHz do 500 kHz od 220 mV do 2,2 V CMC 0,095 % 500 kHz do 1 MHz od 220 mV do 2,2 V CMC 0,18 % 10 Hz do 20 Hz od 2,2 V do 22 V CMC 0,024 % 20 Hz do 40 Hz od 2,2 V do 22 V CMC 0,009 % 40 Hz do 20 kHz od 2,2 V do 22 V CMC 0,006 % 20 kHz do 50 kHz od 2,2 V do 22 V CMC 0,009 % 50 kHz do 100 kHz od 2,2 V do 22 V CMC 0,01 % 100 kHz do 300 kHz od 2,2 V do 22 V CMC 0,04 % 300 kHz do 500 kHz od 2,2 V do 22 V CMC 0,1 % 500 kHz do 1 MHz od 2,2 V do 22 V CMC 0,19 % 10 Hz do 20 Hz od 22 V do 220 V CMC 0,024 % 20 Hz do 40 Hz od 22 V do 220 V CMC 0,009 % 40 Hz do 20 kHz od 22 V do 220 V CMC 0,012 % 20 kHz do 50 kHz od 22 V do 220 V CMC 0,0083 % 50 kHz do 100 kHz od 22 V do 220 V CMC 0,018 % 50 Hz do 1 kHz od 220 V do 1000 V CMC 0,0078 % Stridave napeti / meridla stridaveho napeti Kalibrace – elektricke veliciny Generovani kalibratorem 10 Hz az 20 Hz 0,22 mV az 2,2 mV CMC 0,11 % + 4 µV 20 Hz az 40 Hz 0,22 mV az 2,2 mV CMC 0,11 % + 4 µV 40 Hz az 20 kHz 0,22 mV az 2,2 mV CMC 0,12 % + 4 µV 20 kHz az 50 kHz 0,22 mV az 2,2 mV CMC 0,12 % + 4 µV 50 kHz az 100 kHz 0,22 mV az 2,2 mV CMC 0,13 % + 5 µV 100 kHz az 300 kHz 0,22 mV az 2,2 mV CMC 0,16 % + 10 µV 300 kHz az 500 kHz 0,22 mV az 2,2 mV CMC 0,18 % + 20 µV 500 kHz az 1 MHz 0,22 mV az 2,2 mV CMC 0,38 % + 20 µV 10 Hz az 20 Hz 2,2 mV az 22 mV CMC 0,026 % + 4 µV 20 Hz az 40 Hz 2,2 mV az 22 mV CMC 0,017 % + 4 µV 40 Hz az 20 kHz 2,2 mV az 22 mV CMC 0,016 % + 4 µV 20 kHz az 50 kHz 2,2 mV az 22 mV CMC 0,025 % + 4 µV 50 kHz az 100 kHz 2,2 mV az 22 mV CMC 0,049 % + 5 µV 100 kHz az 300 kHz 2,2 mV az 22 mV CMC 0,12 % + 10 µV 300 kHz az 500 kHz 2,2 mV az 22 mV CMC 0,14 % + 20 µV 500 kHz az 1 MHz 2,2 mV az 22 mV CMC 0,28 % + 20 µV 10 Hz az 20 Hz 22 mV az 220 mV CMC 0,024 % 20 Hz az 40 Hz 22 mV az 220 mV CMC 0,01 % 40 Hz az 20 kHz 22 mV az 220 mV CMC 0,007 % 20 kHz az 50 kHz 22 mV az 220 mV CMC 0,015 % 50 kHz az 100 kHz 22 mV az 220 mV CMC 0,033 % 100 kHz az 300 kHz 22 mV az 220 mV CMC 0,09 % 300 kHz az 500 kHz 22 mV az 220 mV CMC 0,15 % 500 kHz az 1 MHz 22 mV az 220 mV CMC 0,36 % 10 Hz az 20 Hz 220 mV az 2,2 V CMC 0,024 % 20 Hz az 40 Hz 220 mV az 2,2 V CMC 0,009 % 40 Hz az 20 kHz 220 mV az 2,2 V CMC 0,005 % 20 kHz az 50 kHz 220 mV az 2,2 V CMC 0,008 % 50 kHz az 100 kHz 220 mV az 2,2 V CMC 0,019 % 100 kHz az 300 kHz 220 mV az 2,2 V CMC 0,036 % 300 kHz az 500 kHz 220 mV az 2,2 V CMC 0,095 % 500 kHz az 1 MHz 220 mV az 2,2 V CMC 0,18 % 10 Hz az 20 Hz 2,2 V az 22 V CMC 0,024 % 20 Hz az 40 Hz 2,2 V az 22 V CMC 0,009 % 40 Hz az 20 kHz 2,2 V az 22 V CMC 0,006 % 20 kHz az 50 kHz 2,2 V az 22 V CMC 0,009 % 50 kHz az 100 kHz 2,2 V az 22 V CMC 0,01 % 100 kHz az 300 kHz 2,2 V az 22 V CMC 0,04 % 300 kHz az 500 kHz 2,2 V az 22 V CMC 0,1 % 500 kHz az 1 MHz 2,2 V az 22 V CMC 0,19 % 10 Hz az 20 Hz 22 V az 220 V CMC 0,024 % 20 Hz az 40 Hz 22 V az 220 V CMC 0,009 % 40 Hz az 20 kHz 22 V az 220 V CMC 0,012 % 20 kHz az 50 kHz 22 V az 220 V CMC 0,0083 % 50 kHz az 100 kHz 22 V az 220 V CMC 0,018 % 50 Hz az 1 kHz 220 V az 1000 V CMC 0,0078 % CP-004","search_en":"AC voltage / AC voltage meters Calibration – electrical quantities Generation using a calibrator 10 Hz to 20 Hz 0,22 mV to 2,2 mV CMC 0,11 % + 4 µV 20 Hz to 40 Hz 0,22 mV to 2,2 mV CMC 0,11 % + 4 µV 40 Hz to 20 kHz 0,22 mV to 2,2 mV CMC 0,12 % + 4 µV 20 kHz to 50 kHz 0,22 mV to 2,2 mV CMC 0,12 % + 4 µV 50 kHz to 100 kHz 0,22 mV to 2,2 mV CMC 0,13 % + 5 µV 100 kHz to 300 kHz 0,22 mV to 2,2 mV CMC 0,16 % + 10 µV 300 kHz to 500 kHz 0,22 mV to 2,2 mV CMC 0,18 % + 20 µV 500 kHz to 1 MHz 0,22 mV to 2,2 mV CMC 0,38 % + 20 µV 10 Hz to 20 Hz 2,2 mV to 22 mV CMC 0,026 % + 4 µV 20 Hz to 40 Hz 2,2 mV to 22 mV CMC 0,017 % + 4 µV 40 Hz to 20 kHz 2,2 mV to 22 mV CMC 0,016 % + 4 µV 20 kHz to 50 kHz 2,2 mV to 22 mV CMC 0,025 % + 4 µV 50 kHz to 100 kHz 2,2 mV to 22 mV CMC 0,049 % + 5 µV 100 kHz to 300 kHz 2,2 mV to 22 mV CMC 0,12 % + 10 µV 300 kHz to 500 kHz 2,2 mV to 22 mV CMC 0,14 % + 20 µV 500 kHz to 1 MHz 2,2 mV to 22 mV CMC 0,28 % + 20 µV 10 Hz to 20 Hz 22 mV to 220 mV CMC 0,024 % 20 Hz to 40 Hz 22 mV to 220 mV CMC 0,01 % 40 Hz to 20 kHz 22 mV to 220 mV CMC 0,007 % 20 kHz to 50 kHz 22 mV to 220 mV CMC 0,015 % 50 kHz to 100 kHz 22 mV to 220 mV CMC 0,033 % 100 kHz to 300 kHz 22 mV to 220 mV CMC 0,09 % 300 kHz to 500 kHz 22 mV to 220 mV CMC 0,15 % 500 kHz to 1 MHz 22 mV to 220 mV CMC 0,36 % 10 Hz to 20 Hz 220 mV to 2,2 V CMC 0,024 % 20 Hz to 40 Hz 220 mV to 2,2 V CMC 0,009 % 40 Hz to 20 kHz 220 mV to 2,2 V CMC 0,005 % 20 kHz to 50 kHz 220 mV to 2,2 V CMC 0,008 % 50 kHz to 100 kHz 220 mV to 2,2 V CMC 0,019 % 100 kHz to 300 kHz 220 mV to 2,2 V CMC 0,036 % 300 kHz to 500 kHz 220 mV to 2,2 V CMC 0,095 % 500 kHz to 1 MHz 220 mV to 2,2 V CMC 0,18 % 10 Hz to 20 Hz 2,2 V to 22 V CMC 0,024 % 20 Hz to 40 Hz 2,2 V to 22 V CMC 0,009 % 40 Hz to 20 kHz 2,2 V to 22 V CMC 0,006 % 20 kHz to 50 kHz 2,2 V to 22 V CMC 0,009 % 50 kHz to 100 kHz 2,2 V to 22 V CMC 0,01 % 100 kHz to 300 kHz 2,2 V to 22 V CMC 0,04 % 300 kHz to 500 kHz 2,2 V to 22 V CMC 0,1 % 500 kHz to 1 MHz 2,2 V to 22 V CMC 0,19 % 10 Hz to 20 Hz 22 V to 220 V CMC 0,024 % 20 Hz to 40 Hz 22 V to 220 V CMC 0,009 % 40 Hz to 20 kHz 22 V to 220 V CMC 0,012 % 20 kHz to 50 kHz 22 V to 220 V CMC 0,0083 % 50 kHz to 100 kHz 22 V to 220 V CMC 0,018 % 50 Hz to 1 kHz 220 V to 1000 V CMC 0,0078 % CP-004","search_zh":"交流电压 / 交流电压测量仪器 校准 – 电学量 用校准器产生 10 Hz 至 20 Hz 0,22 mV 至 2,2 mV CMC 0,11 % + 4 µV 20 Hz 至 40 Hz 0,22 mV 至 2,2 mV CMC 0,11 % + 4 µV 40 Hz 至 20 kHz 0,22 mV 至 2,2 mV CMC 0,12 % + 4 µV 20 kHz 至 50 kHz 0,22 mV 至 2,2 mV CMC 0,12 % + 4 µV 50 kHz 至 100 kHz 0,22 mV 至 2,2 mV CMC 0,13 % + 5 µV 100 kHz 至 300 kHz 0,22 mV 至 2,2 mV CMC 0,16 % + 10 µV 300 kHz 至 500 kHz 0,22 mV 至 2,2 mV CMC 0,18 % + 20 µV 500 kHz 至 1 MHz 0,22 mV 至 2,2 mV CMC 0,38 % + 20 µV 10 Hz 至 20 Hz 2,2 mV 至 22 mV CMC 0,026 % + 4 µV 20 Hz 至 40 Hz 2,2 mV 至 22 mV CMC 0,017 % + 4 µV 40 Hz 至 20 kHz 2,2 mV 至 22 mV CMC 0,016 % + 4 µV 20 kHz 至 50 kHz 2,2 mV 至 22 mV CMC 0,025 % + 4 µV 50 kHz 至 100 kHz 2,2 mV 至 22 mV CMC 0,049 % + 5 µV 100 kHz 至 300 kHz 2,2 mV 至 22 mV CMC 0,12 % + 10 µV 300 kHz 至 500 kHz 2,2 mV 至 22 mV CMC 0,14 % + 20 µV 500 kHz 至 1 MHz 2,2 mV 至 22 mV CMC 0,28 % + 20 µV 10 Hz 至 20 Hz 22 mV 至 220 mV CMC 0,024 % 20 Hz 至 40 Hz 22 mV 至 220 mV CMC 0,01 % 40 Hz 至 20 kHz 22 mV 至 220 mV CMC 0,007 % 20 kHz 至 50 kHz 22 mV 至 220 mV CMC 0,015 % 50 kHz 至 100 kHz 22 mV 至 220 mV CMC 0,033 % 100 kHz 至 300 kHz 22 mV 至 220 mV CMC 0,09 % 300 kHz 至 500 kHz 22 mV 至 220 mV CMC 0,15 % 500 kHz 至 1 MHz 22 mV 至 220 mV CMC 0,36 % 10 Hz 至 20 Hz 220 mV 至 2,2 V CMC 0,024 % 20 Hz 至 40 Hz 220 mV 至 2,2 V CMC 0,009 % 40 Hz 至 20 kHz 220 mV 至 2,2 V CMC 0,005 % 20 kHz 至 50 kHz 220 mV 至 2,2 V CMC 0,008 % 50 kHz 至 100 kHz 220 mV 至 2,2 V CMC 0,019 % 100 kHz 至 300 kHz 220 mV 至 2,2 V CMC 0,036 % 300 kHz 至 500 kHz 220 mV 至 2,2 V CMC 0,095 % 500 kHz 至 1 MHz 220 mV 至 2,2 V CMC 0,18 % 10 Hz 至 20 Hz 2,2 V 至 22 V CMC 0,024 % 20 Hz 至 40 Hz 2,2 V 至 22 V CMC 0,009 % 40 Hz 至 20 kHz 2,2 V 至 22 V CMC 0,006 % 20 kHz 至 50 kHz 2,2 V 至 22 V CMC 0,009 % 50 kHz 至 100 kHz 2,2 V 至 22 V CMC 0,01 % 100 kHz 至 300 kHz 2,2 V 至 22 V CMC 0,04 % 300 kHz 至 500 kHz 2,2 V 至 22 V CMC 0,1 % 500 kHz 至 1 MHz 2,2 V 至 22 V CMC 0,19 % 10 Hz 至 20 Hz 22 V 至 220 V CMC 0,024 % 20 Hz 至 40 Hz 22 V 至 220 V CMC 0,009 % 40 Hz 至 20 kHz 22 V 至 220 V CMC 0,012 % 20 kHz 至 50 kHz 22 V 至 220 V CMC 0,0083 % 50 kHz 至 100 kHz 22 V 至 220 V CMC 0,018 % 50 Hz 至 1 kHz 220 V 至 1000 V CMC 0,0078 % CP-004","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8b9c1703bf15ebd2ec30c42e","lab_id":"6ade8b5dff06824761708157","country":"CZ","accr_number":"2430","accr_body":"ČIA","row_label":"9","test_object":"Prąd przemienny / źródła i wzorce prądu przemiennego","test_object_en":"AC current / AC current sources and reference standards","test_object_zh":"交流电流 / 交流电流源和标准器","test_object_cs":"Střídavý proud / zdroje a etalony střídavého proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"45 Hz do 5 kHz","range":"od 10 µA do 120 µA","cmc":"79 nA"},{"name":"45 Hz do 5 kHz","range":"od 120 µA do 1,2 mA","cmc":"0,42 µA"},{"name":"45 Hz do 5 kHz","range":"od 1,2 mA do 12 mA","cmc":"0,25 %"},{"name":"45 Hz do 5 kHz","range":"od 12 mA do 120 mA","cmc":"0,26 %"},{"name":"45 Hz do 5 kHz","range":"od 120 mA do 1 A","cmc":"0,29 %"}],"parameters_en":[{"name":"45 Hz to 5 kHz","range":"10 µA to 120 µA","cmc":"79 nA"},{"name":"45 Hz to 5 kHz","range":"120 µA to 1,2 mA","cmc":"0,42 µA"},{"name":"45 Hz to 5 kHz","range":"1,2 mA to 12 mA","cmc":"0,25 %"},{"name":"45 Hz to 5 kHz","range":"12 mA to 120 mA","cmc":"0,26 %"},{"name":"45 Hz to 5 kHz","range":"120 mA to 1 A","cmc":"0,29 %"}],"parameters_zh":[{"name":"45 Hz 至 5 kHz","range":"10 µA 至 120 µA","cmc":"79 nA"},{"name":"45 Hz 至 5 kHz","range":"120 µA 至 1,2 mA","cmc":"0,42 µA"},{"name":"45 Hz 至 5 kHz","range":"1,2 mA 至 12 mA","cmc":"0,25 %"},{"name":"45 Hz 至 5 kHz","range":"12 mA 至 120 mA","cmc":"0,26 %"},{"name":"45 Hz 至 5 kHz","range":"120 mA 至 1 A","cmc":"0,29 %"}],"parameters_cs":[{"name":"45 Hz až 5 kHz","range":"10 µA až 120 µA","cmc":"79 nA"},{"name":"45 Hz až 5 kHz","range":"120 µA až 1,2 mA","cmc":"0,42 µA"},{"name":"45 Hz až 5 kHz","range":"1,2 mA až 12 mA","cmc":"0,25 %"},{"name":"45 Hz až 5 kHz","range":"12 mA až 120 mA","cmc":"0,26 %"},{"name":"45 Hz až 5 kHz","range":"120 mA až 1 A","cmc":"0,29 %"}],"technique":"Pomiar bezpośredni multimetrem wzorcowym","technique_en":"Direct measurement by a reference multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Pomiar bezpośredni multimetrem wzorcowym"],"techniques_en":["Direct measurement by a reference multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n45 Hz do 5 kHz od 10 µA do 120 µA CMC 79 nA\n45 Hz do 5 kHz od 120 µA do 1,2 mA CMC 0,42 µA\n45 Hz do 5 kHz od 1,2 mA do 12 mA CMC 0,25 %\n45 Hz do 5 kHz od 12 mA do 120 mA CMC 0,26 %\n45 Hz do 5 kHz od 120 mA do 1 A CMC 0,29 %\nPomiar bezpośredni multimetrem wzorcowym","reference":"CP-005","norm_bases":["CP-005"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / źródła i wzorce prądu przemiennego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem wzorcowym 45 Hz do 5 kHz od 10 µA do 120 µA CMC 79 nA 45 Hz do 5 kHz od 120 µA do 1,2 mA CMC 0,42 µA 45 Hz do 5 kHz od 1,2 mA do 12 mA CMC 0,25 % 45 Hz do 5 kHz od 12 mA do 120 mA CMC 0,26 % 45 Hz do 5 kHz od 120 mA do 1 A CMC 0,29 % Střídavý proud / zdroje a etalony střídavého proudu Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem 45 Hz až 5 kHz 10 µA až 120 µA CMC 79 nA 45 Hz až 5 kHz 120 µA až 1,2 mA CMC 0,42 µA 45 Hz až 5 kHz 1,2 mA až 12 mA CMC 0,25 % 45 Hz až 5 kHz 12 mA až 120 mA CMC 0,26 % 45 Hz až 5 kHz 120 mA až 1 A CMC 0,29 % CP-005 Prad przemienny / zrodla i wzorce pradu przemiennego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem wzorcowym 45 Hz do 5 kHz od 10 µA do 120 µA CMC 79 nA 45 Hz do 5 kHz od 120 µA do 1,2 mA CMC 0,42 µA 45 Hz do 5 kHz od 1,2 mA do 12 mA CMC 0,25 % 45 Hz do 5 kHz od 12 mA do 120 mA CMC 0,26 % 45 Hz do 5 kHz od 120 mA do 1 A CMC 0,29 % Stridavy proud / zdroje a etalony stridaveho proudu Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem 45 Hz az 5 kHz 10 µA az 120 µA CMC 79 nA 45 Hz az 5 kHz 120 µA az 1,2 mA CMC 0,42 µA 45 Hz az 5 kHz 1,2 mA az 12 mA CMC 0,25 % 45 Hz az 5 kHz 12 mA az 120 mA CMC 0,26 % 45 Hz az 5 kHz 120 mA az 1 A CMC 0,29 % CP-005","search_en":"AC current / AC current sources and reference standards Calibration – electrical quantities Direct measurement by a reference multimeter 45 Hz to 5 kHz 10 µA to 120 µA CMC 79 nA 45 Hz to 5 kHz 120 µA to 1,2 mA CMC 0,42 µA 45 Hz to 5 kHz 1,2 mA to 12 mA CMC 0,25 % 45 Hz to 5 kHz 12 mA to 120 mA CMC 0,26 % 45 Hz to 5 kHz 120 mA to 1 A CMC 0,29 % CP-005","search_zh":"交流电流 / 交流电流源和标准器 校准 – 电学量 用标准万用表直接测量 45 Hz 至 5 kHz 10 µA 至 120 µA CMC 79 nA 45 Hz 至 5 kHz 120 µA 至 1,2 mA CMC 0,42 µA 45 Hz 至 5 kHz 1,2 mA 至 12 mA CMC 0,25 % 45 Hz 至 5 kHz 12 mA 至 120 mA CMC 0,26 % 45 Hz 至 5 kHz 120 mA 至 1 A CMC 0,29 % CP-005","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a04b68c8780e296e1ce8fbac","lab_id":"6ade8b5dff06824761708157","country":"CZ","accr_number":"2430","accr_body":"ČIA","row_label":"10","test_object":"Prąd przemienny / mierniki prądu przemiennego","test_object_en":"AC current / AC current meters","test_object_zh":"交流电流 / 交流电流测量仪器","test_object_cs":"Střídavý proud / měřidla střídavého proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 40 Hz","range":"od 9 µA do 220 µA","cmc":"0,024 % + 16 nA"},{"name":"40 Hz do 1 kHz","range":"od 9 µA do 220 µA","cmc":"0,013 % + 8 nA"},{"name":"1 kHz do 5 kHz","range":"od 9 µA do 220 µA","cmc":"0,036 % + 12 nA"},{"name":"5 kHz do 10 kHz","range":"od 9 µA do 220 µA","cmc":"0,11 % + 63 nA"},{"name":"10 Hz do 40 Hz","range":"od 220 µA do 2,2 mA","cmc":"0,025 %"},{"name":"40 Hz do 1 kHz","range":"od 220 µA do 2,2 mA","cmc":"0,012 %"},{"name":"1 kHz do 5 kHz","range":"od 220 µA do 2,2 mA","cmc":"0,036 %"},{"name":"5 kHz do 10 kHz","range":"od 220 µA do 2,2 mA","cmc":"0,11 %"},{"name":"10 Hz do 40 Hz","range":"od 2,2 mA do 22 mA","cmc":"0,025 %"},{"name":"40 Hz do 1 kHz","range":"od 2,2 mA do 22 mA","cmc":"0,011 %"},{"name":"1 kHz do 5 kHz","range":"od 2,2 mA do 22 mA","cmc":"0,031 %"},{"name":"5 kHz do 10 kHz","range":"od 2,2 mA do 22 mA","cmc":"0,11 %"},{"name":"10 Hz do 40 Hz","range":"od 22 mA do 220 mA","cmc":"0,024 %"},{"name":"40 Hz do 1 kHz","range":"od 22 mA do 220 mA","cmc":"0,012 %"},{"name":"1 kHz do 5 kHz","range":"od 22 mA do 220 mA","cmc":"0,031 %"},{"name":"5 kHz do 10 kHz","range":"od 22 mA do 220 mA","cmc":"0,11 %"},{"name":"20 Hz do 1 kHz","range":"od 220 mA do 2,2 A","cmc":"0,027 %"},{"name":"1 kHz do 5 kHz","range":"od 220 mA do 2,2 A","cmc":"0,046 %"},{"name":"5 kHz do 10 kHz","range":"od 220 mA do 2,2 A","cmc":"0,62 %"}],"parameters_en":[{"name":"10 Hz to 40 Hz","range":"9 µA to 220 µA","cmc":"0,024 % + 16 nA"},{"name":"40 Hz to 1 kHz","range":"9 µA to 220 µA","cmc":"0,013 % + 8 nA"},{"name":"1 kHz to 5 kHz","range":"9 µA to 220 µA","cmc":"0,036 % + 12 nA"},{"name":"5 kHz to 10 kHz","range":"9 µA to 220 µA","cmc":"0,11 % + 63 nA"},{"name":"10 Hz to 40 Hz","range":"220 µA to 2,2 mA","cmc":"0,025 %"},{"name":"40 Hz to 1 kHz","range":"220 µA to 2,2 mA","cmc":"0,012 %"},{"name":"1 kHz to 5 kHz","range":"220 µA to 2,2 mA","cmc":"0,036 %"},{"name":"5 kHz to 10 kHz","range":"220 µA to 2,2 mA","cmc":"0,11 %"},{"name":"10 Hz to 40 Hz","range":"2,2 mA to 22 mA","cmc":"0,025 %"},{"name":"40 Hz to 1 kHz","range":"2,2 mA to 22 mA","cmc":"0,011 %"},{"name":"1 kHz to 5 kHz","range":"2,2 mA to 22 mA","cmc":"0,031 %"},{"name":"5 kHz to 10 kHz","range":"2,2 mA to 22 mA","cmc":"0,11 %"},{"name":"10 Hz to 40 Hz","range":"22 mA to 220 mA","cmc":"0,024 %"},{"name":"40 Hz to 1 kHz","range":"22 mA to 220 mA","cmc":"0,012 %"},{"name":"1 kHz to 5 kHz","range":"22 mA to 220 mA","cmc":"0,031 %"},{"name":"5 kHz to 10 kHz","range":"22 mA to 220 mA","cmc":"0,11 %"},{"name":"20 Hz to 1 kHz","range":"220 mA to 2,2 A","cmc":"0,027 %"},{"name":"1 kHz to 5 kHz","range":"220 mA to 2,2 A","cmc":"0,046 %"},{"name":"5 kHz to 10 kHz","range":"220 mA to 2,2 A","cmc":"0,62 %"}],"parameters_zh":[{"name":"10 Hz 至 40 Hz","range":"9 µA 至 220 µA","cmc":"0,024 % + 16 nA"},{"name":"40 Hz 至 1 kHz","range":"9 µA 至 220 µA","cmc":"0,013 % + 8 nA"},{"name":"1 kHz 至 5 kHz","range":"9 µA 至 220 µA","cmc":"0,036 % + 12 nA"},{"name":"5 kHz 至 10 kHz","range":"9 µA 至 220 µA","cmc":"0,11 % + 63 nA"},{"name":"10 Hz 至 40 Hz","range":"220 µA 至 2,2 mA","cmc":"0,025 %"},{"name":"40 Hz 至 1 kHz","range":"220 µA 至 2,2 mA","cmc":"0,012 %"},{"name":"1 kHz 至 5 kHz","range":"220 µA 至 2,2 mA","cmc":"0,036 %"},{"name":"5 kHz 至 10 kHz","range":"220 µA 至 2,2 mA","cmc":"0,11 %"},{"name":"10 Hz 至 40 Hz","range":"2,2 mA 至 22 mA","cmc":"0,025 %"},{"name":"40 Hz 至 1 kHz","range":"2,2 mA 至 22 mA","cmc":"0,011 %"},{"name":"1 kHz 至 5 kHz","range":"2,2 mA 至 22 mA","cmc":"0,031 %"},{"name":"5 kHz 至 10 kHz","range":"2,2 mA 至 22 mA","cmc":"0,11 %"},{"name":"10 Hz 至 40 Hz","range":"22 mA 至 220 mA","cmc":"0,024 %"},{"name":"40 Hz 至 1 kHz","range":"22 mA 至 220 mA","cmc":"0,012 %"},{"name":"1 kHz 至 5 kHz","range":"22 mA 至 220 mA","cmc":"0,031 %"},{"name":"5 kHz 至 10 kHz","range":"22 mA 至 220 mA","cmc":"0,11 %"},{"name":"20 Hz 至 1 kHz","range":"220 mA 至 2,2 A","cmc":"0,027 %"},{"name":"1 kHz 至 5 kHz","range":"220 mA 至 2,2 A","cmc":"0,046 %"},{"name":"5 kHz 至 10 kHz","range":"220 mA 至 2,2 A","cmc":"0,62 %"}],"parameters_cs":[{"name":"10 Hz až 40 Hz","range":"9 µA až 220 µA","cmc":"0,024 % + 16 nA"},{"name":"40 Hz až 1 kHz","range":"9 µA až 220 µA","cmc":"0,013 % + 8 nA"},{"name":"1 kHz až 5 kHz","range":"9 µA až 220 µA","cmc":"0,036 % + 12 nA"},{"name":"5 kHz až 10 kHz","range":"9 µA až 220 µA","cmc":"0,11 % + 63 nA"},{"name":"10 Hz až 40 Hz","range":"220 µA až 2,2 mA","cmc":"0,025 %"},{"name":"40 Hz až 1 kHz","range":"220 µA až 2,2 mA","cmc":"0,012 %"},{"name":"1 kHz až 5 kHz","range":"220 µA až 2,2 mA","cmc":"0,036 %"},{"name":"5 kHz až 10 kHz","range":"220 µA až 2,2 mA","cmc":"0,11 %"},{"name":"10 Hz až 40 Hz","range":"2,2 mA až 22 mA","cmc":"0,025 %"},{"name":"40 Hz až 1 kHz","range":"2,2 mA až 22 mA","cmc":"0,011 %"},{"name":"1 kHz až 5 kHz","range":"2,2 mA až 22 mA","cmc":"0,031 %"},{"name":"5 kHz až 10 kHz","range":"2,2 mA až 22 mA","cmc":"0,11 %"},{"name":"10 Hz až 40 Hz","range":"22 mA až 220 mA","cmc":"0,024 %"},{"name":"40 Hz až 1 kHz","range":"22 mA až 220 mA","cmc":"0,012 %"},{"name":"1 kHz až 5 kHz","range":"22 mA až 220 mA","cmc":"0,031 %"},{"name":"5 kHz až 10 kHz","range":"22 mA až 220 mA","cmc":"0,11 %"},{"name":"20 Hz až 1 kHz","range":"220 mA až 2,2 A","cmc":"0,027 %"},{"name":"1 kHz až 5 kHz","range":"220 mA až 2,2 A","cmc":"0,046 %"},{"name":"5 kHz až 10 kHz","range":"220 mA až 2,2 A","cmc":"0,62 %"}],"technique":"Generowanie kalibratorem","technique_en":"Generation using a calibrator","technique_zh":"用校准器产生","technique_cs":"Generování kalibrátorem","techniques":["Generowanie kalibratorem"],"techniques_en":["Generation using a calibrator"],"techniques_zh":["用校准器产生"],"techniques_cs":["Generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 40 Hz od 9 µA do 220 µA CMC 0,024 % + 16 nA\n40 Hz do 1 kHz od 9 µA do 220 µA CMC 0,013 % + 8 nA\n1 kHz do 5 kHz od 9 µA do 220 µA CMC 0,036 % + 12 nA\n5 kHz do 10 kHz od 9 µA do 220 µA CMC 0,11 % + 63 nA\n10 Hz do 40 Hz od 220 µA do 2,2 mA CMC 0,025 %\n40 Hz do 1 kHz od 220 µA do 2,2 mA CMC 0,012 %\n1 kHz do 5 kHz od 220 µA do 2,2 mA CMC 0,036 %\n5 kHz do 10 kHz od 220 µA do 2,2 mA CMC 0,11 %\n10 Hz do 40 Hz od 2,2 mA do 22 mA CMC 0,025 %\n40 Hz do 1 kHz od 2,2 mA do 22 mA CMC 0,011 %\n1 kHz do 5 kHz od 2,2 mA do 22 mA CMC 0,031 %\n5 kHz do 10 kHz od 2,2 mA do 22 mA CMC 0,11 %\n10 Hz do 40 Hz od 22 mA do 220 mA CMC 0,024 %\n40 Hz do 1 kHz od 22 mA do 220 mA CMC 0,012 %\n1 kHz do 5 kHz od 22 mA do 220 mA CMC 0,031 %\n5 kHz do 10 kHz od 22 mA do 220 mA CMC 0,11 %\n20 Hz do 1 kHz od 220 mA do 2,2 A CMC 0,027 %\n1 kHz do 5 kHz od 220 mA do 2,2 A CMC 0,046 %\n5 kHz do 10 kHz od 220 mA do 2,2 A CMC 0,62 %\nGenerowanie kalibratorem","reference":"CP-005","norm_bases":["CP-005"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / mierniki prądu przemiennego Wzorcowanie – wielkości elektryczne Generowanie kalibratorem 10 Hz do 40 Hz od 9 µA do 220 µA CMC 0,024 % + 16 nA 40 Hz do 1 kHz od 9 µA do 220 µA CMC 0,013 % + 8 nA 1 kHz do 5 kHz od 9 µA do 220 µA CMC 0,036 % + 12 nA 5 kHz do 10 kHz od 9 µA do 220 µA CMC 0,11 % + 63 nA 10 Hz do 40 Hz od 220 µA do 2,2 mA CMC 0,025 % 40 Hz do 1 kHz od 220 µA do 2,2 mA CMC 0,012 % 1 kHz do 5 kHz od 220 µA do 2,2 mA CMC 0,036 % 5 kHz do 10 kHz od 220 µA do 2,2 mA CMC 0,11 % 10 Hz do 40 Hz od 2,2 mA do 22 mA CMC 0,025 % 40 Hz do 1 kHz od 2,2 mA do 22 mA CMC 0,011 % 1 kHz do 5 kHz od 2,2 mA do 22 mA CMC 0,031 % 5 kHz do 10 kHz od 2,2 mA do 22 mA CMC 0,11 % 10 Hz do 40 Hz od 22 mA do 220 mA CMC 0,024 % 40 Hz do 1 kHz od 22 mA do 220 mA CMC 0,012 % 1 kHz do 5 kHz od 22 mA do 220 mA CMC 0,031 % 5 kHz do 10 kHz od 22 mA do 220 mA CMC 0,11 % 20 Hz do 1 kHz od 220 mA do 2,2 A CMC 0,027 % 1 kHz do 5 kHz od 220 mA do 2,2 A CMC 0,046 % 5 kHz do 10 kHz od 220 mA do 2,2 A CMC 0,62 % Střídavý proud / měřidla střídavého proudu Kalibrace – elektrické veličiny Generování kalibrátorem 10 Hz až 40 Hz 9 µA až 220 µA CMC 0,024 % + 16 nA 40 Hz až 1 kHz 9 µA až 220 µA CMC 0,013 % + 8 nA 1 kHz až 5 kHz 9 µA až 220 µA CMC 0,036 % + 12 nA 5 kHz až 10 kHz 9 µA až 220 µA CMC 0,11 % + 63 nA 10 Hz až 40 Hz 220 µA až 2,2 mA CMC 0,025 % 40 Hz až 1 kHz 220 µA až 2,2 mA CMC 0,012 % 1 kHz až 5 kHz 220 µA až 2,2 mA CMC 0,036 % 5 kHz až 10 kHz 220 µA až 2,2 mA CMC 0,11 % 10 Hz až 40 Hz 2,2 mA až 22 mA CMC 0,025 % 40 Hz až 1 kHz 2,2 mA až 22 mA CMC 0,011 % 1 kHz až 5 kHz 2,2 mA až 22 mA CMC 0,031 % 5 kHz až 10 kHz 2,2 mA až 22 mA CMC 0,11 % 10 Hz až 40 Hz 22 mA až 220 mA CMC 0,024 % 40 Hz až 1 kHz 22 mA až 220 mA CMC 0,012 % 1 kHz až 5 kHz 22 mA až 220 mA CMC 0,031 % 5 kHz až 10 kHz 22 mA až 220 mA CMC 0,11 % 20 Hz až 1 kHz 220 mA až 2,2 A CMC 0,027 % 1 kHz až 5 kHz 220 mA až 2,2 A CMC 0,046 % 5 kHz až 10 kHz 220 mA až 2,2 A CMC 0,62 % CP-005 Prad przemienny / mierniki pradu przemiennego Wzorcowanie – wielkosci elektryczne Generowanie kalibratorem 10 Hz do 40 Hz od 9 µA do 220 µA CMC 0,024 % + 16 nA 40 Hz do 1 kHz od 9 µA do 220 µA CMC 0,013 % + 8 nA 1 kHz do 5 kHz od 9 µA do 220 µA CMC 0,036 % + 12 nA 5 kHz do 10 kHz od 9 µA do 220 µA CMC 0,11 % + 63 nA 10 Hz do 40 Hz od 220 µA do 2,2 mA CMC 0,025 % 40 Hz do 1 kHz od 220 µA do 2,2 mA CMC 0,012 % 1 kHz do 5 kHz od 220 µA do 2,2 mA CMC 0,036 % 5 kHz do 10 kHz od 220 µA do 2,2 mA CMC 0,11 % 10 Hz do 40 Hz od 2,2 mA do 22 mA CMC 0,025 % 40 Hz do 1 kHz od 2,2 mA do 22 mA CMC 0,011 % 1 kHz do 5 kHz od 2,2 mA do 22 mA CMC 0,031 % 5 kHz do 10 kHz od 2,2 mA do 22 mA CMC 0,11 % 10 Hz do 40 Hz od 22 mA do 220 mA CMC 0,024 % 40 Hz do 1 kHz od 22 mA do 220 mA CMC 0,012 % 1 kHz do 5 kHz od 22 mA do 220 mA CMC 0,031 % 5 kHz do 10 kHz od 22 mA do 220 mA CMC 0,11 % 20 Hz do 1 kHz od 220 mA do 2,2 A CMC 0,027 % 1 kHz do 5 kHz od 220 mA do 2,2 A CMC 0,046 % 5 kHz do 10 kHz od 220 mA do 2,2 A CMC 0,62 % Stridavy proud / meridla stridaveho proudu Kalibrace – elektricke veliciny Generovani kalibratorem 10 Hz az 40 Hz 9 µA az 220 µA CMC 0,024 % + 16 nA 40 Hz az 1 kHz 9 µA az 220 µA CMC 0,013 % + 8 nA 1 kHz az 5 kHz 9 µA az 220 µA CMC 0,036 % + 12 nA 5 kHz az 10 kHz 9 µA az 220 µA CMC 0,11 % + 63 nA 10 Hz az 40 Hz 220 µA az 2,2 mA CMC 0,025 % 40 Hz az 1 kHz 220 µA az 2,2 mA CMC 0,012 % 1 kHz az 5 kHz 220 µA az 2,2 mA CMC 0,036 % 5 kHz az 10 kHz 220 µA az 2,2 mA CMC 0,11 % 10 Hz az 40 Hz 2,2 mA az 22 mA CMC 0,025 % 40 Hz az 1 kHz 2,2 mA az 22 mA CMC 0,011 % 1 kHz az 5 kHz 2,2 mA az 22 mA CMC 0,031 % 5 kHz az 10 kHz 2,2 mA az 22 mA CMC 0,11 % 10 Hz az 40 Hz 22 mA az 220 mA CMC 0,024 % 40 Hz az 1 kHz 22 mA az 220 mA CMC 0,012 % 1 kHz az 5 kHz 22 mA az 220 mA CMC 0,031 % 5 kHz az 10 kHz 22 mA az 220 mA CMC 0,11 % 20 Hz az 1 kHz 220 mA az 2,2 A CMC 0,027 % 1 kHz az 5 kHz 220 mA az 2,2 A CMC 0,046 % 5 kHz az 10 kHz 220 mA az 2,2 A CMC 0,62 % CP-005","search_en":"AC current / AC current meters Calibration – electrical quantities Generation using a calibrator 10 Hz to 40 Hz 9 µA to 220 µA CMC 0,024 % + 16 nA 40 Hz to 1 kHz 9 µA to 220 µA CMC 0,013 % + 8 nA 1 kHz to 5 kHz 9 µA to 220 µA CMC 0,036 % + 12 nA 5 kHz to 10 kHz 9 µA to 220 µA CMC 0,11 % + 63 nA 10 Hz to 40 Hz 220 µA to 2,2 mA CMC 0,025 % 40 Hz to 1 kHz 220 µA to 2,2 mA CMC 0,012 % 1 kHz to 5 kHz 220 µA to 2,2 mA CMC 0,036 % 5 kHz to 10 kHz 220 µA to 2,2 mA CMC 0,11 % 10 Hz to 40 Hz 2,2 mA to 22 mA CMC 0,025 % 40 Hz to 1 kHz 2,2 mA to 22 mA CMC 0,011 % 1 kHz to 5 kHz 2,2 mA to 22 mA CMC 0,031 % 5 kHz to 10 kHz 2,2 mA to 22 mA CMC 0,11 % 10 Hz to 40 Hz 22 mA to 220 mA CMC 0,024 % 40 Hz to 1 kHz 22 mA to 220 mA CMC 0,012 % 1 kHz to 5 kHz 22 mA to 220 mA CMC 0,031 % 5 kHz to 10 kHz 22 mA to 220 mA CMC 0,11 % 20 Hz to 1 kHz 220 mA to 2,2 A CMC 0,027 % 1 kHz to 5 kHz 220 mA to 2,2 A CMC 0,046 % 5 kHz to 10 kHz 220 mA to 2,2 A CMC 0,62 % CP-005","search_zh":"交流电流 / 交流电流测量仪器 校准 – 电学量 用校准器产生 10 Hz 至 40 Hz 9 µA 至 220 µA CMC 0,024 % + 16 nA 40 Hz 至 1 kHz 9 µA 至 220 µA CMC 0,013 % + 8 nA 1 kHz 至 5 kHz 9 µA 至 220 µA CMC 0,036 % + 12 nA 5 kHz 至 10 kHz 9 µA 至 220 µA CMC 0,11 % + 63 nA 10 Hz 至 40 Hz 220 µA 至 2,2 mA CMC 0,025 % 40 Hz 至 1 kHz 220 µA 至 2,2 mA CMC 0,012 % 1 kHz 至 5 kHz 220 µA 至 2,2 mA CMC 0,036 % 5 kHz 至 10 kHz 220 µA 至 2,2 mA CMC 0,11 % 10 Hz 至 40 Hz 2,2 mA 至 22 mA CMC 0,025 % 40 Hz 至 1 kHz 2,2 mA 至 22 mA CMC 0,011 % 1 kHz 至 5 kHz 2,2 mA 至 22 mA CMC 0,031 % 5 kHz 至 10 kHz 2,2 mA 至 22 mA CMC 0,11 % 10 Hz 至 40 Hz 22 mA 至 220 mA CMC 0,024 % 40 Hz 至 1 kHz 22 mA 至 220 mA CMC 0,012 % 1 kHz 至 5 kHz 22 mA 至 220 mA CMC 0,031 % 5 kHz 至 10 kHz 22 mA 至 220 mA CMC 0,11 % 20 Hz 至 1 kHz 220 mA 至 2,2 A CMC 0,027 % 1 kHz 至 5 kHz 220 mA 至 2,2 A CMC 0,046 % 5 kHz 至 10 kHz 220 mA 至 2,2 A CMC 0,62 % CP-005","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3174f6dfa589e9cc2b04c2e7","lab_id":"6ade8b5dff06824761708157","country":"CZ","accr_number":"2430","accr_body":"ČIA","row_label":"1","test_object":"Częstotliwość / generatory sygnałów, oscylatory odniesienia","test_object_en":"Frequency / signal generators, reference oscillators","test_object_zh":"频率 / 信号发生器、参考振荡器","test_object_cs":"Frekvence / generátory signálu, referenční oscilátory","methodology":"Wzorcowanie – częstotliwość","methodology_en":"Calibration – frequency","methodology_zh":"校准 – 频率","methodology_cs":"Kalibrace – frekvence","parameters":[{"name":"","range":"od 0,01 Hz do 0,1 Hz","cmc":"2 x 10⁻³"},{"name":"","range":"od 0,1 Hz do 1 Hz","cmc":"2 x 10⁻⁴"},{"name":"","range":"od 1 Hz do 10 Hz","cmc":"4 x 10⁻⁵"},{"name":"","range":"od 10 Hz do 100 Hz","cmc":"4 x 10⁻⁶"},{"name":"","range":"od 100 Hz do 1 kHz","cmc":"4 x 10⁻⁷"},{"name":"","range":"od 1 kHz do 10 kHz","cmc":"4 x 10⁻⁸"},{"name":"","range":"od 10 kHz do 100 kHz","cmc":"4 x 10⁻⁹"},{"name":"","range":"od 100 kHz do 1 MHz","cmc":"4 x 10⁻⁹"},{"name":"","range":"od 1 MHz do 3 GHz","cmc":"4 x 10⁻¹⁰"}],"parameters_en":[{"name":"","range":"0,01 Hz to 0,1 Hz","cmc":"2 x 10⁻³"},{"name":"","range":"0,1 Hz to 1 Hz","cmc":"2 x 10⁻⁴"},{"name":"","range":"1 Hz to 10 Hz","cmc":"4 x 10⁻⁵"},{"name":"","range":"10 Hz to 100 Hz","cmc":"4 x 10⁻⁶"},{"name":"","range":"100 Hz to 1 kHz","cmc":"4 x 10⁻⁷"},{"name":"","range":"1 kHz to 10 kHz","cmc":"4 x 10⁻⁸"},{"name":"","range":"10 kHz to 100 kHz","cmc":"4 x 10⁻⁹"},{"name":"","range":"100 kHz to 1 MHz","cmc":"4 x 10⁻⁹"},{"name":"","range":"1 MHz to 3 GHz","cmc":"4 x 10⁻¹⁰"}],"parameters_zh":[{"name":"","range":"0,01 Hz 至 0,1 Hz","cmc":"2 x 10⁻³"},{"name":"","range":"0,1 Hz 至 1 Hz","cmc":"2 x 10⁻⁴"},{"name":"","range":"1 Hz 至 10 Hz","cmc":"4 x 10⁻⁵"},{"name":"","range":"10 Hz 至 100 Hz","cmc":"4 x 10⁻⁶"},{"name":"","range":"100 Hz 至 1 kHz","cmc":"4 x 10⁻⁷"},{"name":"","range":"1 kHz 至 10 kHz","cmc":"4 x 10⁻⁸"},{"name":"","range":"10 kHz 至 100 kHz","cmc":"4 x 10⁻⁹"},{"name":"","range":"100 kHz 至 1 MHz","cmc":"4 x 10⁻⁹"},{"name":"","range":"1 MHz 至 3 GHz","cmc":"4 x 10⁻¹⁰"}],"parameters_cs":[{"name":"","range":"0,01 Hz až 0,1 Hz","cmc":"2 x 10⁻³"},{"name":"","range":"0,1 Hz až 1 Hz","cmc":"2 x 10⁻⁴"},{"name":"","range":"1 Hz až 10 Hz","cmc":"4 x 10⁻⁵"},{"name":"","range":"10 Hz až 100 Hz","cmc":"4 x 10⁻⁶"},{"name":"","range":"100 Hz až 1 kHz","cmc":"4 x 10⁻⁷"},{"name":"","range":"1 kHz až 10 kHz","cmc":"4 x 10⁻⁸"},{"name":"","range":"10 kHz až 100 kHz","cmc":"4 x 10⁻⁹"},{"name":"","range":"100 kHz až 1 MHz","cmc":"4 x 10⁻⁹"},{"name":"","range":"1 MHz až 3 GHz","cmc":"4 x 10⁻¹⁰"}],"technique":"Pomiar bezpośredni częstotliwości licznikiem wzorcowym","technique_en":"Direct frequency measurement with a reference counter","technique_zh":"用标准计数器直接测量频率","technique_cs":"Přímé měření frekvence etalonovým čítačem","techniques":["Pomiar bezpośredni częstotliwości licznikiem wzorcowym"],"techniques_en":["Direct frequency measurement with a reference counter"],"techniques_zh":["用标准计数器直接测量频率"],"techniques_cs":["Přímé měření frekvence etalonovým čítačem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – częstotliwość\nZakres:\nod 0,01 Hz do 0,1 Hz CMC 2 x 10⁻³\nod 0,1 Hz do 1 Hz CMC 2 x 10⁻⁴\nod 1 Hz do 10 Hz CMC 4 x 10⁻⁵\nod 10 Hz do 100 Hz CMC 4 x 10⁻⁶\nod 100 Hz do 1 kHz CMC 4 x 10⁻⁷\nod 1 kHz do 10 kHz CMC 4 x 10⁻⁸\nod 10 kHz do 100 kHz CMC 4 x 10⁻⁹\nod 100 kHz do 1 MHz CMC 4 x 10⁻⁹\nod 1 MHz do 3 GHz CMC 4 x 10⁻¹⁰\nPomiar bezpośredni częstotliwości licznikiem wzorcowym","reference":"CP-006","norm_bases":["CP-006"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: częstotliwość","regulatory_area_en":"CMC for the field of measured quantity: Frequency","regulatory_area_zh":"被测量领域的CMC：频率","regulatory_area_cs":"CMC pro obor měřené veličiny: Frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Częstotliwość / generatory sygnałów, oscylatory odniesienia Wzorcowanie – częstotliwość Pomiar bezpośredni częstotliwości licznikiem wzorcowym od 0,01 Hz do 0,1 Hz CMC 2 x 10⁻³ od 0,1 Hz do 1 Hz CMC 2 x 10⁻⁴ od 1 Hz do 10 Hz CMC 4 x 10⁻⁵ od 10 Hz do 100 Hz CMC 4 x 10⁻⁶ od 100 Hz do 1 kHz CMC 4 x 10⁻⁷ od 1 kHz do 10 kHz CMC 4 x 10⁻⁸ od 10 kHz do 100 kHz CMC 4 x 10⁻⁹ od 100 kHz do 1 MHz CMC 4 x 10⁻⁹ od 1 MHz do 3 GHz CMC 4 x 10⁻¹⁰ Frekvence / generátory signálu, referenční oscilátory Kalibrace – frekvence Přímé měření frekvence etalonovým čítačem 0,01 Hz až 0,1 Hz CMC 2 x 10⁻³ 0,1 Hz až 1 Hz CMC 2 x 10⁻⁴ 1 Hz až 10 Hz CMC 4 x 10⁻⁵ 10 Hz až 100 Hz CMC 4 x 10⁻⁶ 100 Hz až 1 kHz CMC 4 x 10⁻⁷ 1 kHz až 10 kHz CMC 4 x 10⁻⁸ 10 kHz až 100 kHz CMC 4 x 10⁻⁹ 100 kHz až 1 MHz CMC 4 x 10⁻⁹ 1 MHz až 3 GHz CMC 4 x 10⁻¹⁰ CP-006 Czestotliwosc / generatory sygnalow, oscylatory odniesienia Wzorcowanie – czestotliwosc Pomiar bezposredni czestotliwosci licznikiem wzorcowym od 0,01 Hz do 0,1 Hz CMC 2 x 10⁻³ od 0,1 Hz do 1 Hz CMC 2 x 10⁻⁴ od 1 Hz do 10 Hz CMC 4 x 10⁻⁵ od 10 Hz do 100 Hz CMC 4 x 10⁻⁶ od 100 Hz do 1 kHz CMC 4 x 10⁻⁷ od 1 kHz do 10 kHz CMC 4 x 10⁻⁸ od 10 kHz do 100 kHz CMC 4 x 10⁻⁹ od 100 kHz do 1 MHz CMC 4 x 10⁻⁹ od 1 MHz do 3 GHz CMC 4 x 10⁻¹⁰ Frekvence / generatory signalu, referencni oscilatory Kalibrace – frekvence Prime mereni frekvence etalonovym citacem 0,01 Hz az 0,1 Hz CMC 2 x 10⁻³ 0,1 Hz az 1 Hz CMC 2 x 10⁻⁴ 1 Hz az 10 Hz CMC 4 x 10⁻⁵ 10 Hz az 100 Hz CMC 4 x 10⁻⁶ 100 Hz az 1 kHz CMC 4 x 10⁻⁷ 1 kHz az 10 kHz CMC 4 x 10⁻⁸ 10 kHz az 100 kHz CMC 4 x 10⁻⁹ 100 kHz az 1 MHz CMC 4 x 10⁻⁹ 1 MHz az 3 GHz CMC 4 x 10⁻¹⁰ CP-006","search_en":"Frequency / signal generators, reference oscillators Calibration – frequency Direct frequency measurement with a reference counter 0,01 Hz to 0,1 Hz CMC 2 x 10⁻³ 0,1 Hz to 1 Hz CMC 2 x 10⁻⁴ 1 Hz to 10 Hz CMC 4 x 10⁻⁵ 10 Hz to 100 Hz CMC 4 x 10⁻⁶ 100 Hz to 1 kHz CMC 4 x 10⁻⁷ 1 kHz to 10 kHz CMC 4 x 10⁻⁸ 10 kHz to 100 kHz CMC 4 x 10⁻⁹ 100 kHz to 1 MHz CMC 4 x 10⁻⁹ 1 MHz to 3 GHz CMC 4 x 10⁻¹⁰ CP-006","search_zh":"频率 / 信号发生器、参考振荡器 校准 – 频率 用标准计数器直接测量频率 0,01 Hz 至 0,1 Hz CMC 2 x 10⁻³ 0,1 Hz 至 1 Hz CMC 2 x 10⁻⁴ 1 Hz 至 10 Hz CMC 4 x 10⁻⁵ 10 Hz 至 100 Hz CMC 4 x 10⁻⁶ 100 Hz 至 1 kHz CMC 4 x 10⁻⁷ 1 kHz 至 10 kHz CMC 4 x 10⁻⁸ 10 kHz 至 100 kHz CMC 4 x 10⁻⁹ 100 kHz 至 1 MHz CMC 4 x 10⁻⁹ 1 MHz 至 3 GHz CMC 4 x 10⁻¹⁰ CP-006","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"61cc4b13f2169aa1a203d253","lab_id":"6ade8b5dff06824761708157","country":"CZ","accr_number":"2430","accr_body":"ČIA","row_label":"2","test_object":"Częstotliwość / liczniki, multimetry, mierniki częstotliwości","test_object_en":"Frequency / counters, multimeters, frequency meters","test_object_zh":"频率 / 计数器、万用表、频率计","test_object_cs":"Frekvence / čítače, multimetry, měřidla frekvence","methodology":"Wzorcowanie – częstotliwość","methodology_en":"Calibration – frequency","methodology_zh":"校准 – 频率","methodology_cs":"Kalibrace – frekvence","parameters":[{"name":"","range":"od 0,01 Hz do 0,1 Hz","cmc":"2 x 10⁻³"},{"name":"","range":"od 0,1 Hz do 1 Hz","cmc":"2 x 10⁻⁴"},{"name":"","range":"od 1 Hz do 10 Hz","cmc":"4 x 10⁻⁵"},{"name":"","range":"od 10 Hz do 100 Hz","cmc":"4 x 10⁻⁶"},{"name":"","range":"od 100 Hz do 1 kHz","cmc":"4 x 10⁻⁷"},{"name":"","range":"od 1 kHz do 10 kHz","cmc":"4 x 10⁻⁸"},{"name":"","range":"od 10 kHz do 100 kHz","cmc":"4 x 10⁻⁹"},{"name":"","range":"od 100 kHz do 1 MHz","cmc":"4 x 10⁻⁹"},{"name":"","range":"od 1 MHz do 6 GHz","cmc":"4 x 10⁻¹⁰"}],"parameters_en":[{"name":"","range":"0,01 Hz to 0,1 Hz","cmc":"2 x 10⁻³"},{"name":"","range":"0,1 Hz to 1 Hz","cmc":"2 x 10⁻⁴"},{"name":"","range":"1 Hz to 10 Hz","cmc":"4 x 10⁻⁵"},{"name":"","range":"10 Hz to 100 Hz","cmc":"4 x 10⁻⁶"},{"name":"","range":"100 Hz to 1 kHz","cmc":"4 x 10⁻⁷"},{"name":"","range":"1 kHz to 10 kHz","cmc":"4 x 10⁻⁸"},{"name":"","range":"10 kHz to 100 kHz","cmc":"4 x 10⁻⁹"},{"name":"","range":"100 kHz to 1 MHz","cmc":"4 x 10⁻⁹"},{"name":"","range":"1 MHz to 6 GHz","cmc":"4 x 10⁻¹⁰"}],"parameters_zh":[{"name":"","range":"0,01 Hz 至 0,1 Hz","cmc":"2 x 10⁻³"},{"name":"","range":"0,1 Hz 至 1 Hz","cmc":"2 x 10⁻⁴"},{"name":"","range":"1 Hz 至 10 Hz","cmc":"4 x 10⁻⁵"},{"name":"","range":"10 Hz 至 100 Hz","cmc":"4 x 10⁻⁶"},{"name":"","range":"100 Hz 至 1 kHz","cmc":"4 x 10⁻⁷"},{"name":"","range":"1 kHz 至 10 kHz","cmc":"4 x 10⁻⁸"},{"name":"","range":"10 kHz 至 100 kHz","cmc":"4 x 10⁻⁹"},{"name":"","range":"100 kHz 至 1 MHz","cmc":"4 x 10⁻⁹"},{"name":"","range":"1 MHz 至 6 GHz","cmc":"4 x 10⁻¹⁰"}],"parameters_cs":[{"name":"","range":"0,01 Hz až 0,1 Hz","cmc":"2 x 10⁻³"},{"name":"","range":"0,1 Hz až 1 Hz","cmc":"2 x 10⁻⁴"},{"name":"","range":"1 Hz až 10 Hz","cmc":"4 x 10⁻⁵"},{"name":"","range":"10 Hz až 100 Hz","cmc":"4 x 10⁻⁶"},{"name":"","range":"100 Hz až 1 kHz","cmc":"4 x 10⁻⁷"},{"name":"","range":"1 kHz až 10 kHz","cmc":"4 x 10⁻⁸"},{"name":"","range":"10 kHz až 100 kHz","cmc":"4 x 10⁻⁹"},{"name":"","range":"100 kHz až 1 MHz","cmc":"4 x 10⁻⁹"},{"name":"","range":"1 MHz až 6 GHz","cmc":"4 x 10⁻¹⁰"}],"technique":"Bezpośrednie generowanie częstotliwości generatorem wzorcowym","technique_en":"Direct frequency generation using a reference generator","technique_zh":"用标准发生器直接产生频率","technique_cs":"Přímé generování frekvence etalonovým generátorem","techniques":["Bezpośrednie generowanie częstotliwości generatorem wzorcowym"],"techniques_en":["Direct frequency generation using a reference generator"],"techniques_zh":["用标准发生器直接产生频率"],"techniques_cs":["Přímé generování frekvence etalonovým generátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – częstotliwość\nZakres:\nod 0,01 Hz do 0,1 Hz CMC 2 x 10⁻³\nod 0,1 Hz do 1 Hz CMC 2 x 10⁻⁴\nod 1 Hz do 10 Hz CMC 4 x 10⁻⁵\nod 10 Hz do 100 Hz CMC 4 x 10⁻⁶\nod 100 Hz do 1 kHz CMC 4 x 10⁻⁷\nod 1 kHz do 10 kHz CMC 4 x 10⁻⁸\nod 10 kHz do 100 kHz CMC 4 x 10⁻⁹\nod 100 kHz do 1 MHz CMC 4 x 10⁻⁹\nod 1 MHz do 6 GHz CMC 4 x 10⁻¹⁰\nBezpośrednie generowanie częstotliwości generatorem wzorcowym","reference":"CP-006","norm_bases":["CP-006"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: częstotliwość","regulatory_area_en":"CMC for the field of measured quantity: Frequency","regulatory_area_zh":"被测量领域的CMC：频率","regulatory_area_cs":"CMC pro obor měřené veličiny: Frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Częstotliwość / liczniki, multimetry, mierniki częstotliwości Wzorcowanie – częstotliwość Bezpośrednie generowanie częstotliwości generatorem wzorcowym od 0,01 Hz do 0,1 Hz CMC 2 x 10⁻³ od 0,1 Hz do 1 Hz CMC 2 x 10⁻⁴ od 1 Hz do 10 Hz CMC 4 x 10⁻⁵ od 10 Hz do 100 Hz CMC 4 x 10⁻⁶ od 100 Hz do 1 kHz CMC 4 x 10⁻⁷ od 1 kHz do 10 kHz CMC 4 x 10⁻⁸ od 10 kHz do 100 kHz CMC 4 x 10⁻⁹ od 100 kHz do 1 MHz CMC 4 x 10⁻⁹ od 1 MHz do 6 GHz CMC 4 x 10⁻¹⁰ Frekvence / čítače, multimetry, měřidla frekvence Kalibrace – frekvence Přímé generování frekvence etalonovým generátorem 0,01 Hz až 0,1 Hz CMC 2 x 10⁻³ 0,1 Hz až 1 Hz CMC 2 x 10⁻⁴ 1 Hz až 10 Hz CMC 4 x 10⁻⁵ 10 Hz až 100 Hz CMC 4 x 10⁻⁶ 100 Hz až 1 kHz CMC 4 x 10⁻⁷ 1 kHz až 10 kHz CMC 4 x 10⁻⁸ 10 kHz až 100 kHz CMC 4 x 10⁻⁹ 100 kHz až 1 MHz CMC 4 x 10⁻⁹ 1 MHz až 6 GHz CMC 4 x 10⁻¹⁰ CP-006 Czestotliwosc / liczniki, multimetry, mierniki czestotliwosci Wzorcowanie – czestotliwosc Bezposrednie generowanie czestotliwosci generatorem wzorcowym od 0,01 Hz do 0,1 Hz CMC 2 x 10⁻³ od 0,1 Hz do 1 Hz CMC 2 x 10⁻⁴ od 1 Hz do 10 Hz CMC 4 x 10⁻⁵ od 10 Hz do 100 Hz CMC 4 x 10⁻⁶ od 100 Hz do 1 kHz CMC 4 x 10⁻⁷ od 1 kHz do 10 kHz CMC 4 x 10⁻⁸ od 10 kHz do 100 kHz CMC 4 x 10⁻⁹ od 100 kHz do 1 MHz CMC 4 x 10⁻⁹ od 1 MHz do 6 GHz CMC 4 x 10⁻¹⁰ Frekvence / citace, multimetry, meridla frekvence Kalibrace – frekvence Prime generovani frekvence etalonovym generatorem 0,01 Hz az 0,1 Hz CMC 2 x 10⁻³ 0,1 Hz az 1 Hz CMC 2 x 10⁻⁴ 1 Hz az 10 Hz CMC 4 x 10⁻⁵ 10 Hz az 100 Hz CMC 4 x 10⁻⁶ 100 Hz az 1 kHz CMC 4 x 10⁻⁷ 1 kHz az 10 kHz CMC 4 x 10⁻⁸ 10 kHz az 100 kHz CMC 4 x 10⁻⁹ 100 kHz az 1 MHz CMC 4 x 10⁻⁹ 1 MHz az 6 GHz CMC 4 x 10⁻¹⁰ CP-006","search_en":"Frequency / counters, multimeters, frequency meters Calibration – frequency Direct frequency generation using a reference generator 0,01 Hz to 0,1 Hz CMC 2 x 10⁻³ 0,1 Hz to 1 Hz CMC 2 x 10⁻⁴ 1 Hz to 10 Hz CMC 4 x 10⁻⁵ 10 Hz to 100 Hz CMC 4 x 10⁻⁶ 100 Hz to 1 kHz CMC 4 x 10⁻⁷ 1 kHz to 10 kHz CMC 4 x 10⁻⁸ 10 kHz to 100 kHz CMC 4 x 10⁻⁹ 100 kHz to 1 MHz CMC 4 x 10⁻⁹ 1 MHz to 6 GHz CMC 4 x 10⁻¹⁰ CP-006","search_zh":"频率 / 计数器、万用表、频率计 校准 – 频率 用标准发生器直接产生频率 0,01 Hz 至 0,1 Hz CMC 2 x 10⁻³ 0,1 Hz 至 1 Hz CMC 2 x 10⁻⁴ 1 Hz 至 10 Hz CMC 4 x 10⁻⁵ 10 Hz 至 100 Hz CMC 4 x 10⁻⁶ 100 Hz 至 1 kHz CMC 4 x 10⁻⁷ 1 kHz 至 10 kHz CMC 4 x 10⁻⁸ 10 kHz 至 100 kHz CMC 4 x 10⁻⁹ 100 kHz 至 1 MHz CMC 4 x 10⁻⁹ 1 MHz 至 6 GHz CMC 4 x 10⁻¹⁰ CP-006","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}