{"lab":{"_id":"6ade8b57ff0682476170814c","accr_number":"2417","country":"CZ","accr_body":"ČIA","address":"Růžová 5363, 430 04 Chomutov","categories":["metrology"],"city":"Chomutov","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[13.4364952,50.4914542]},"map_coord":[50.4914542,13.4364952],"map_geo":"cai-mapa","methods_count":12,"name":"PG electronic s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinie wielkości elektrycznych, w zakresie określonym w załączniku do świadectwa.","search_text":"pg electronic s.r.o. růžová 5363, 430 04 chomutov 2417","source_page_url":"https://www.cai.cz/?subjekt=2417-pg-electronic-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"16-10-2030","website":"www.pgelectronic.cz","certificate_date":"16.10.2025","certificate_no":"513/2025","certificate_replaces":"689/2023 z 20.12.2023","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinie wielkości elektrycznych, w zakresie określonym w załączniku do świadectwa.","en":"Calibration in the field of electrical quantities to the extent as specified in the appendix to this Certificate.","zh":"电学量领域的校准，范围见本证书附件。","cs":"Kalibrace v oboru elektrických veličin, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące","lab_division_cs":"Kalibrační laboratoř","lab_division_en":"Calibration Laboratory","lab_division_zh":"校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"d74fecbef0cde8d3ec2da10f86913d24e6eb4196f1d38d516ba2b347a678dafc","source_pdf_url":"https://www.cai.cz/OA/pdf/513_2025_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/513_2025_EN.pdf"},"methods":[{"_id":"0344361f5df0e08597b1dbde","lab_id":"6ade8b57ff0682476170814c","country":"CZ","accr_number":"2417","accr_body":"ČIA","row_label":"1","test_object":"Napięcie stałe / źródła napięcia stałego, testery wielofunkcyjne","test_object_en":"DC voltage / DC voltage sources, multifunction testers","test_object_zh":"直流电压 / 直流电压源、多功能测试仪","test_object_cs":"Stejnosměrné napětí / zdroje stejnosměrného napětí, multifunkční testery","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mV do 100 mV","cmc":"0,003 % + 3 µV"},{"name":"","range":"od 100 mV do 1 V","cmc":"0,002 % + 6 µV"},{"name":"","range":"od 1 V do 10 V","cmc":"0,002 % + 40 µV"},{"name":"","range":"od 10 V do 100 V","cmc":"0,003 % + 0,5 mV"},{"name":"","range":"od 100 V do 1 kV","cmc":"0,004 % + 8 mV"},{"name":"","range":"od 1 kV do 6 kV","cmc":"0,2 % + 70 mV"}],"parameters_en":[{"name":"","range":"0 mV to 100 mV","cmc":"0,003 % + 3 µV"},{"name":"","range":"100 mV to 1 V","cmc":"0,002 % + 6 µV"},{"name":"","range":"1 V to 10 V","cmc":"0,002 % + 40 µV"},{"name":"","range":"10 V to 100 V","cmc":"0,003 % + 0,5 mV"},{"name":"","range":"100 V to 1 kV","cmc":"0,004 % + 8 mV"},{"name":"","range":"1 kV to 6 kV","cmc":"0,2 % + 70 mV"}],"parameters_zh":[{"name":"","range":"0 mV 至 100 mV","cmc":"0,003 % + 3 µV"},{"name":"","range":"100 mV 至 1 V","cmc":"0,002 % + 6 µV"},{"name":"","range":"1 V 至 10 V","cmc":"0,002 % + 40 µV"},{"name":"","range":"10 V 至 100 V","cmc":"0,003 % + 0,5 mV"},{"name":"","range":"100 V 至 1 kV","cmc":"0,004 % + 8 mV"},{"name":"","range":"1 kV 至 6 kV","cmc":"0,2 % + 70 mV"}],"parameters_cs":[{"name":"","range":"0 mV až 100 mV","cmc":"0,003 % + 3 µV"},{"name":"","range":"100 mV až 1 V","cmc":"0,002 % + 6 µV"},{"name":"","range":"1 V až 10 V","cmc":"0,002 % + 40 µV"},{"name":"","range":"10 V až 100 V","cmc":"0,003 % + 0,5 mV"},{"name":"","range":"100 V až 1 kV","cmc":"0,004 % + 8 mV"},{"name":"","range":"1 kV až 6 kV","cmc":"0,2 % + 70 mV"}],"technique":"Pomiar bezpośredni multimetrem wzorcowym","technique_en":"Direct measurement by a standard multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Pomiar bezpośredni multimetrem wzorcowym"],"techniques_en":["Direct measurement by a standard multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mV do 100 mV CMC 0,003 % + 3 µV\nod 100 mV do 1 V CMC 0,002 % + 6 µV\nod 1 V do 10 V CMC 0,002 % + 40 µV\nod 10 V do 100 V CMC 0,003 % + 0,5 mV\nod 100 V do 1 kV CMC 0,004 % + 8 mV\nod 1 kV do 6 kV CMC 0,2 % + 70 mV\nPomiar bezpośredni multimetrem wzorcowym","reference":"KA-01","norm_bases":["KA-01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / źródła napięcia stałego, testery wielofunkcyjne Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem wzorcowym od 0 mV do 100 mV CMC 0,003 % + 3 µV od 100 mV do 1 V CMC 0,002 % + 6 µV od 1 V do 10 V CMC 0,002 % + 40 µV od 10 V do 100 V CMC 0,003 % + 0,5 mV od 100 V do 1 kV CMC 0,004 % + 8 mV od 1 kV do 6 kV CMC 0,2 % + 70 mV Stejnosměrné napětí / zdroje stejnosměrného napětí, multifunkční testery Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem 0 mV až 100 mV CMC 0,003 % + 3 µV 100 mV až 1 V CMC 0,002 % + 6 µV 1 V až 10 V CMC 0,002 % + 40 µV 10 V až 100 V CMC 0,003 % + 0,5 mV 100 V až 1 kV CMC 0,004 % + 8 mV 1 kV až 6 kV CMC 0,2 % + 70 mV KA-01 Napiecie stale / zrodla napiecia stalego, testery wielofunkcyjne Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem wzorcowym od 0 mV do 100 mV CMC 0,003 % + 3 µV od 100 mV do 1 V CMC 0,002 % + 6 µV od 1 V do 10 V CMC 0,002 % + 40 µV od 10 V do 100 V CMC 0,003 % + 0,5 mV od 100 V do 1 kV CMC 0,004 % + 8 mV od 1 kV do 6 kV CMC 0,2 % + 70 mV Stejnosmerne napeti / zdroje stejnosmerneho napeti, multifunkcni testery Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem 0 mV az 100 mV CMC 0,003 % + 3 µV 100 mV az 1 V CMC 0,002 % + 6 µV 1 V az 10 V CMC 0,002 % + 40 µV 10 V az 100 V CMC 0,003 % + 0,5 mV 100 V az 1 kV CMC 0,004 % + 8 mV 1 kV az 6 kV CMC 0,2 % + 70 mV KA-01","search_en":"DC voltage / DC voltage sources, multifunction testers Calibration – electrical quantities Direct measurement by a standard multimeter 0 mV to 100 mV CMC 0,003 % + 3 µV 100 mV to 1 V CMC 0,002 % + 6 µV 1 V to 10 V CMC 0,002 % + 40 µV 10 V to 100 V CMC 0,003 % + 0,5 mV 100 V to 1 kV CMC 0,004 % + 8 mV 1 kV to 6 kV CMC 0,2 % + 70 mV KA-01","search_zh":"直流电压 / 直流电压源、多功能测试仪 校准 – 电学量 用标准万用表直接测量 0 mV 至 100 mV CMC 0,003 % + 3 µV 100 mV 至 1 V CMC 0,002 % + 6 µV 1 V 至 10 V CMC 0,002 % + 40 µV 10 V 至 100 V CMC 0,003 % + 0,5 mV 100 V 至 1 kV CMC 0,004 % + 8 mV 1 kV 至 6 kV CMC 0,2 % + 70 mV KA-01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"baf7d35418eec71ad08119eb","lab_id":"6ade8b57ff0682476170814c","country":"CZ","accr_number":"2417","accr_body":"ČIA","row_label":"2","test_object":"Napięcie przemienne / źródła napięcia przemiennego, testery wielofunkcyjne","test_object_en":"AC voltage / AC voltage sources, multifunction testers","test_object_zh":"交流电压 / 交流电压源、多功能测试仪","test_object_cs":"Střídavé napětí / zdroje střídavého napětí, multifunkční testery","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"20 Hz do 1 kHz","range":"od 5 mV do 100 mV","cmc":"0,05 % + 40 µV"},{"name":"20 Hz do 1 kHz","range":"od 100 mV do 1 V","cmc":"0,05 % + 0,3 mV"},{"name":"20 Hz do 1 kHz","range":"od 1 V do 10 V","cmc":"0,05 % + 3 mV"},{"name":"20 Hz do 1 kHz","range":"od 10 V do 100 V","cmc":"0,05 % + 30 mV"},{"name":"20 Hz do 1 kHz","range":"od 100 V do 1 kV","cmc":"0,05 % + 0,2 V"},{"name":"20 Hz do 1 kHz","range":"od 1 kV do 5 kV","cmc":"0,3 % + 4 V"}],"parameters_en":[{"name":"20 Hz to 1 kHz","range":"5 mV to 100 mV","cmc":"0,05 % + 40 µV"},{"name":"20 Hz to 1 kHz","range":"100 mV to 1 V","cmc":"0,05 % + 0,3 mV"},{"name":"20 Hz to 1 kHz","range":"1 V to 10 V","cmc":"0,05 % + 3 mV"},{"name":"20 Hz to 1 kHz","range":"10 V to 100 V","cmc":"0,05 % + 30 mV"},{"name":"20 Hz to 1 kHz","range":"100 V to 1 kV","cmc":"0,05 % + 0,2 V"},{"name":"20 Hz to 1 kHz","range":"1 kV to 5 kV","cmc":"0,3 % + 4 V"}],"parameters_zh":[{"name":"20 Hz 至 1 kHz","range":"5 mV 至 100 mV","cmc":"0,05 % + 40 µV"},{"name":"20 Hz 至 1 kHz","range":"100 mV 至 1 V","cmc":"0,05 % + 0,3 mV"},{"name":"20 Hz 至 1 kHz","range":"1 V 至 10 V","cmc":"0,05 % + 3 mV"},{"name":"20 Hz 至 1 kHz","range":"10 V 至 100 V","cmc":"0,05 % + 30 mV"},{"name":"20 Hz 至 1 kHz","range":"100 V 至 1 kV","cmc":"0,05 % + 0,2 V"},{"name":"20 Hz 至 1 kHz","range":"1 kV 至 5 kV","cmc":"0,3 % + 4 V"}],"parameters_cs":[{"name":"20 Hz až 1 kHz","range":"5 mV až 100 mV","cmc":"0,05 % + 40 µV"},{"name":"20 Hz až 1 kHz","range":"100 mV až 1 V","cmc":"0,05 % + 0,3 mV"},{"name":"20 Hz až 1 kHz","range":"1 V až 10 V","cmc":"0,05 % + 3 mV"},{"name":"20 Hz až 1 kHz","range":"10 V až 100 V","cmc":"0,05 % + 30 mV"},{"name":"20 Hz až 1 kHz","range":"100 V až 1 kV","cmc":"0,05 % + 0,2 V"},{"name":"20 Hz až 1 kHz","range":"1 kV až 5 kV","cmc":"0,3 % + 4 V"}],"technique":"Pomiar bezpośredni multimetrem wzorcowym","technique_en":"Direct measurement by a standard multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Pomiar bezpośredni multimetrem wzorcowym"],"techniques_en":["Direct measurement by a standard multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n20 Hz do 1 kHz od 5 mV do 100 mV CMC 0,05 % + 40 µV\n20 Hz do 1 kHz od 100 mV do 1 V CMC 0,05 % + 0,3 mV\n20 Hz do 1 kHz od 1 V do 10 V CMC 0,05 % + 3 mV\n20 Hz do 1 kHz od 10 V do 100 V CMC 0,05 % + 30 mV\n20 Hz do 1 kHz od 100 V do 1 kV CMC 0,05 % + 0,2 V\n20 Hz do 1 kHz od 1 kV do 5 kV CMC 0,3 % + 4 V\nPomiar bezpośredni multimetrem wzorcowym","reference":"KA-02","norm_bases":["KA-02"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / źródła napięcia przemiennego, testery wielofunkcyjne Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem wzorcowym 20 Hz do 1 kHz od 5 mV do 100 mV CMC 0,05 % + 40 µV 20 Hz do 1 kHz od 100 mV do 1 V CMC 0,05 % + 0,3 mV 20 Hz do 1 kHz od 1 V do 10 V CMC 0,05 % + 3 mV 20 Hz do 1 kHz od 10 V do 100 V CMC 0,05 % + 30 mV 20 Hz do 1 kHz od 100 V do 1 kV CMC 0,05 % + 0,2 V 20 Hz do 1 kHz od 1 kV do 5 kV CMC 0,3 % + 4 V Střídavé napětí / zdroje střídavého napětí, multifunkční testery Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem 20 Hz až 1 kHz 5 mV až 100 mV CMC 0,05 % + 40 µV 20 Hz až 1 kHz 100 mV až 1 V CMC 0,05 % + 0,3 mV 20 Hz až 1 kHz 1 V až 10 V CMC 0,05 % + 3 mV 20 Hz až 1 kHz 10 V až 100 V CMC 0,05 % + 30 mV 20 Hz až 1 kHz 100 V až 1 kV CMC 0,05 % + 0,2 V 20 Hz až 1 kHz 1 kV až 5 kV CMC 0,3 % + 4 V KA-02 Napiecie przemienne / zrodla napiecia przemiennego, testery wielofunkcyjne Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem wzorcowym 20 Hz do 1 kHz od 5 mV do 100 mV CMC 0,05 % + 40 µV 20 Hz do 1 kHz od 100 mV do 1 V CMC 0,05 % + 0,3 mV 20 Hz do 1 kHz od 1 V do 10 V CMC 0,05 % + 3 mV 20 Hz do 1 kHz od 10 V do 100 V CMC 0,05 % + 30 mV 20 Hz do 1 kHz od 100 V do 1 kV CMC 0,05 % + 0,2 V 20 Hz do 1 kHz od 1 kV do 5 kV CMC 0,3 % + 4 V Stridave napeti / zdroje stridaveho napeti, multifunkcni testery Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem 20 Hz az 1 kHz 5 mV az 100 mV CMC 0,05 % + 40 µV 20 Hz az 1 kHz 100 mV az 1 V CMC 0,05 % + 0,3 mV 20 Hz az 1 kHz 1 V az 10 V CMC 0,05 % + 3 mV 20 Hz az 1 kHz 10 V az 100 V CMC 0,05 % + 30 mV 20 Hz az 1 kHz 100 V az 1 kV CMC 0,05 % + 0,2 V 20 Hz az 1 kHz 1 kV az 5 kV CMC 0,3 % + 4 V KA-02","search_en":"AC voltage / AC voltage sources, multifunction testers Calibration – electrical quantities Direct measurement by a standard multimeter 20 Hz to 1 kHz 5 mV to 100 mV CMC 0,05 % + 40 µV 20 Hz to 1 kHz 100 mV to 1 V CMC 0,05 % + 0,3 mV 20 Hz to 1 kHz 1 V to 10 V CMC 0,05 % + 3 mV 20 Hz to 1 kHz 10 V to 100 V CMC 0,05 % + 30 mV 20 Hz to 1 kHz 100 V to 1 kV CMC 0,05 % + 0,2 V 20 Hz to 1 kHz 1 kV to 5 kV CMC 0,3 % + 4 V KA-02","search_zh":"交流电压 / 交流电压源、多功能测试仪 校准 – 电学量 用标准万用表直接测量 20 Hz 至 1 kHz 5 mV 至 100 mV CMC 0,05 % + 40 µV 20 Hz 至 1 kHz 100 mV 至 1 V CMC 0,05 % + 0,3 mV 20 Hz 至 1 kHz 1 V 至 10 V CMC 0,05 % + 3 mV 20 Hz 至 1 kHz 10 V 至 100 V CMC 0,05 % + 30 mV 20 Hz 至 1 kHz 100 V 至 1 kV CMC 0,05 % + 0,2 V 20 Hz 至 1 kHz 1 kV 至 5 kV CMC 0,3 % + 4 V KA-02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"87da537c95d926ff9c9da631","lab_id":"6ade8b57ff0682476170814c","country":"CZ","accr_number":"2417","accr_body":"ČIA","row_label":"3","test_object":"Prąd stały / źródła prądu stałego, testery wielofunkcyjne","test_object_en":"DC current / DC current sources, multifunction testers","test_object_zh":"直流电流 / 直流电流源、多功能测试仪","test_object_cs":"Stejnosměrný proud / zdroje stejnosměrného proudu, multifunkční testery","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 1 µA do 100 µA","cmc":"0,04 % + 0,03 µA"},{"name":"","range":"od 100 µA do 1 mA","cmc":"0,04 % + 0,04 µA"},{"name":"","range":"od 1 mA do 10 mA","cmc":"0,04 % + 2 µA"},{"name":"","range":"od 10 mA do 100 mA","cmc":"0,04 % + 4 µA"},{"name":"","range":"od 100 mA do 400 mA","cmc":"0,04 % + 20 µA"},{"name":"","range":"od 400 mA do 1 A","cmc":"0,04 % + 0,2 mA"},{"name":"","range":"od 1 A do 3 A","cmc":"0,09 % + 0,6 mA"},{"name":"","range":"od 3 A do 10 A","cmc":"0,2 % + 0,7 mA"}],"parameters_en":[{"name":"","range":"1 µA to 100 µA","cmc":"0,04 % + 0,03 µA"},{"name":"","range":"100 µA to 1 mA","cmc":"0,04 % + 0,04 µA"},{"name":"","range":"1 mA to 10 mA","cmc":"0,04 % + 2 µA"},{"name":"","range":"10 mA to 100 mA","cmc":"0,04 % + 4 µA"},{"name":"","range":"100 mA to 400 mA","cmc":"0,04 % + 20 µA"},{"name":"","range":"400 mA to 1 A","cmc":"0,04 % + 0,2 mA"},{"name":"","range":"1 A to 3 A","cmc":"0,09 % + 0,6 mA"},{"name":"","range":"3 A to 10 A","cmc":"0,2 % + 0,7 mA"}],"parameters_zh":[{"name":"","range":"1 µA 至 100 µA","cmc":"0,04 % + 0,03 µA"},{"name":"","range":"100 µA 至 1 mA","cmc":"0,04 % + 0,04 µA"},{"name":"","range":"1 mA 至 10 mA","cmc":"0,04 % + 2 µA"},{"name":"","range":"10 mA 至 100 mA","cmc":"0,04 % + 4 µA"},{"name":"","range":"100 mA 至 400 mA","cmc":"0,04 % + 20 µA"},{"name":"","range":"400 mA 至 1 A","cmc":"0,04 % + 0,2 mA"},{"name":"","range":"1 A 至 3 A","cmc":"0,09 % + 0,6 mA"},{"name":"","range":"3 A 至 10 A","cmc":"0,2 % + 0,7 mA"}],"parameters_cs":[{"name":"","range":"1 µA až 100 µA","cmc":"0,04 % + 0,03 µA"},{"name":"","range":"100 µA až 1 mA","cmc":"0,04 % + 0,04 µA"},{"name":"","range":"1 mA až 10 mA","cmc":"0,04 % + 2 µA"},{"name":"","range":"10 mA až 100 mA","cmc":"0,04 % + 4 µA"},{"name":"","range":"100 mA až 400 mA","cmc":"0,04 % + 20 µA"},{"name":"","range":"400 mA až 1 A","cmc":"0,04 % + 0,2 mA"},{"name":"","range":"1 A až 3 A","cmc":"0,09 % + 0,6 mA"},{"name":"","range":"3 A až 10 A","cmc":"0,2 % + 0,7 mA"}],"technique":"Pomiar bezpośredni multimetrem wzorcowym","technique_en":"Direct measurement by a standard multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Pomiar bezpośredni multimetrem wzorcowym"],"techniques_en":["Direct measurement by a standard multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 1 µA do 100 µA CMC 0,04 % + 0,03 µA\nod 100 µA do 1 mA CMC 0,04 % + 0,04 µA\nod 1 mA do 10 mA CMC 0,04 % + 2 µA\nod 10 mA do 100 mA CMC 0,04 % + 4 µA\nod 100 mA do 400 mA CMC 0,04 % + 20 µA\nod 400 mA do 1 A CMC 0,04 % + 0,2 mA\nod 1 A do 3 A CMC 0,09 % + 0,6 mA\nod 3 A do 10 A CMC 0,2 % + 0,7 mA\nPomiar bezpośredni multimetrem wzorcowym","reference":"KA-03","norm_bases":["KA-03"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / źródła prądu stałego, testery wielofunkcyjne Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem wzorcowym od 1 µA do 100 µA CMC 0,04 % + 0,03 µA od 100 µA do 1 mA CMC 0,04 % + 0,04 µA od 1 mA do 10 mA CMC 0,04 % + 2 µA od 10 mA do 100 mA CMC 0,04 % + 4 µA od 100 mA do 400 mA CMC 0,04 % + 20 µA od 400 mA do 1 A CMC 0,04 % + 0,2 mA od 1 A do 3 A CMC 0,09 % + 0,6 mA od 3 A do 10 A CMC 0,2 % + 0,7 mA Stejnosměrný proud / zdroje stejnosměrného proudu, multifunkční testery Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem 1 µA až 100 µA CMC 0,04 % + 0,03 µA 100 µA až 1 mA CMC 0,04 % + 0,04 µA 1 mA až 10 mA CMC 0,04 % + 2 µA 10 mA až 100 mA CMC 0,04 % + 4 µA 100 mA až 400 mA CMC 0,04 % + 20 µA 400 mA až 1 A CMC 0,04 % + 0,2 mA 1 A až 3 A CMC 0,09 % + 0,6 mA 3 A až 10 A CMC 0,2 % + 0,7 mA KA-03 Prad staly / zrodla pradu stalego, testery wielofunkcyjne Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem wzorcowym od 1 µA do 100 µA CMC 0,04 % + 0,03 µA od 100 µA do 1 mA CMC 0,04 % + 0,04 µA od 1 mA do 10 mA CMC 0,04 % + 2 µA od 10 mA do 100 mA CMC 0,04 % + 4 µA od 100 mA do 400 mA CMC 0,04 % + 20 µA od 400 mA do 1 A CMC 0,04 % + 0,2 mA od 1 A do 3 A CMC 0,09 % + 0,6 mA od 3 A do 10 A CMC 0,2 % + 0,7 mA Stejnosmerny proud / zdroje stejnosmerneho proudu, multifunkcni testery Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem 1 µA az 100 µA CMC 0,04 % + 0,03 µA 100 µA az 1 mA CMC 0,04 % + 0,04 µA 1 mA az 10 mA CMC 0,04 % + 2 µA 10 mA az 100 mA CMC 0,04 % + 4 µA 100 mA az 400 mA CMC 0,04 % + 20 µA 400 mA az 1 A CMC 0,04 % + 0,2 mA 1 A az 3 A CMC 0,09 % + 0,6 mA 3 A az 10 A CMC 0,2 % + 0,7 mA KA-03","search_en":"DC current / DC current sources, multifunction testers Calibration – electrical quantities Direct measurement by a standard multimeter 1 µA to 100 µA CMC 0,04 % + 0,03 µA 100 µA to 1 mA CMC 0,04 % + 0,04 µA 1 mA to 10 mA CMC 0,04 % + 2 µA 10 mA to 100 mA CMC 0,04 % + 4 µA 100 mA to 400 mA CMC 0,04 % + 20 µA 400 mA to 1 A CMC 0,04 % + 0,2 mA 1 A to 3 A CMC 0,09 % + 0,6 mA 3 A to 10 A CMC 0,2 % + 0,7 mA KA-03","search_zh":"直流电流 / 直流电流源、多功能测试仪 校准 – 电学量 用标准万用表直接测量 1 µA 至 100 µA CMC 0,04 % + 0,03 µA 100 µA 至 1 mA CMC 0,04 % + 0,04 µA 1 mA 至 10 mA CMC 0,04 % + 2 µA 10 mA 至 100 mA CMC 0,04 % + 4 µA 100 mA 至 400 mA CMC 0,04 % + 20 µA 400 mA 至 1 A CMC 0,04 % + 0,2 mA 1 A 至 3 A CMC 0,09 % + 0,6 mA 3 A 至 10 A CMC 0,2 % + 0,7 mA KA-03","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"367ff689d75fcb23cc7eaa6d","lab_id":"6ade8b57ff0682476170814c","country":"CZ","accr_number":"2417","accr_body":"ČIA","row_label":"3","test_object":"Prąd stały / źródła prądu stałego, testery wielofunkcyjne","test_object_en":"DC current / DC current sources, multifunction testers","test_object_zh":"直流电流 / 直流电流源、多功能测试仪","test_object_cs":"Stejnosměrný proud / zdroje stejnosměrného proudu, multifunkční testery","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 10 A do 30 A","cmc":"0,35 %"}],"parameters_en":[{"name":"","range":"10 A to 30 A","cmc":"0,35 %"}],"parameters_zh":[{"name":"","range":"10 A 至 30 A","cmc":"0,35 %"}],"parameters_cs":[{"name":"","range":"10 A až 30 A","cmc":"0,35 %"}],"technique":"Pomiar multimetrem wzorcowym z bocznikiem","technique_en":"Measurement by a reference multimeter with a shunt","technique_zh":"用带分流器的标准万用表测量","technique_cs":"Měření etalonovým multimetrem s bočníkem","techniques":["Pomiar multimetrem wzorcowym z bocznikiem"],"techniques_en":["Measurement by a reference multimeter with a shunt"],"techniques_zh":["用带分流器的标准万用表测量"],"techniques_cs":["Měření etalonovým multimetrem s bočníkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 10 A do 30 A CMC 0,35 %\nPomiar multimetrem wzorcowym z bocznikiem","reference":"KA-03","norm_bases":["KA-03"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / źródła prądu stałego, testery wielofunkcyjne Wzorcowanie – wielkości elektryczne Pomiar multimetrem wzorcowym z bocznikiem od 10 A do 30 A CMC 0,35 % Stejnosměrný proud / zdroje stejnosměrného proudu, multifunkční testery Kalibrace – elektrické veličiny Měření etalonovým multimetrem s bočníkem 10 A až 30 A CMC 0,35 % KA-03 Prad staly / zrodla pradu stalego, testery wielofunkcyjne Wzorcowanie – wielkosci elektryczne Pomiar multimetrem wzorcowym z bocznikiem od 10 A do 30 A CMC 0,35 % Stejnosmerny proud / zdroje stejnosmerneho proudu, multifunkcni testery Kalibrace – elektricke veliciny Mereni etalonovym multimetrem s bocnikem 10 A az 30 A CMC 0,35 % KA-03","search_en":"DC current / DC current sources, multifunction testers Calibration – electrical quantities Measurement by a reference multimeter with a shunt 10 A to 30 A CMC 0,35 % KA-03","search_zh":"直流电流 / 直流电流源、多功能测试仪 校准 – 电学量 用带分流器的标准万用表测量 10 A 至 30 A CMC 0,35 % KA-03","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"109448901c49bfd2840549fa","lab_id":"6ade8b57ff0682476170814c","country":"CZ","accr_number":"2417","accr_body":"ČIA","row_label":"4","test_object":"Prąd przemienny / źródła prądu przemiennego, testery wielofunkcyjne","test_object_en":"AC current / AC current sources, multifunction testers","test_object_zh":"交流电流 / 交流电流源、多功能测试仪","test_object_cs":"Střídavý proud / zdroje střídavého proudu, multifunkční testery","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"20 Hz do 1 kHz","range":"od 10 µA do 100 µA","cmc":"0,2 µA"},{"name":"20 Hz do 1 kHz","range":"od 100 µA do 1 mA","cmc":"0,08 % + 0,4 µA"},{"name":"20 Hz do 1 kHz","range":"od 1 mA do 10 mA","cmc":"0,2 % + 5 µA"},{"name":"20 Hz do 1 kHz","range":"od 10 mA do 100 mA","cmc":"0,07 % + 40 µA"},{"name":"20 Hz do 1 kHz","range":"od 100 mA do 400 mA","cmc":"0,2 % + 0,4 mA"},{"name":"20 Hz do 1 kHz","range":"od 400 mA do 1 A","cmc":"0,07 % + 0,7 mA"},{"name":"20 Hz do 1 kHz","range":"od 1 A do 3 A","cmc":"0,09 % + 3 mA"},{"name":"20 Hz do 1 kHz","range":"od 3 A do 10 A","cmc":"0,2 % + 7 mA"}],"parameters_en":[{"name":"20 Hz to 1 kHz","range":"10 µA to 100 µA","cmc":"0,2 µA"},{"name":"20 Hz to 1 kHz","range":"100 µA to 1 mA","cmc":"0,08 % + 0,4 µA"},{"name":"20 Hz to 1 kHz","range":"1 mA to 10 mA","cmc":"0,2 % + 5 µA"},{"name":"20 Hz to 1 kHz","range":"10 mA to 100 mA","cmc":"0,07 % + 40 µA"},{"name":"20 Hz to 1 kHz","range":"100 mA to 400 mA","cmc":"0,2 % + 0,4 mA"},{"name":"20 Hz to 1 kHz","range":"400 mA to 1 A","cmc":"0,07 % + 0,7 mA"},{"name":"20 Hz to 1 kHz","range":"1 A to 3 A","cmc":"0,09 % + 3 mA"},{"name":"20 Hz to 1 kHz","range":"3 A to 10 A","cmc":"0,2 % + 7 mA"}],"parameters_zh":[{"name":"20 Hz 至 1 kHz","range":"10 µA 至 100 µA","cmc":"0,2 µA"},{"name":"20 Hz 至 1 kHz","range":"100 µA 至 1 mA","cmc":"0,08 % + 0,4 µA"},{"name":"20 Hz 至 1 kHz","range":"1 mA 至 10 mA","cmc":"0,2 % + 5 µA"},{"name":"20 Hz 至 1 kHz","range":"10 mA 至 100 mA","cmc":"0,07 % + 40 µA"},{"name":"20 Hz 至 1 kHz","range":"100 mA 至 400 mA","cmc":"0,2 % + 0,4 mA"},{"name":"20 Hz 至 1 kHz","range":"400 mA 至 1 A","cmc":"0,07 % + 0,7 mA"},{"name":"20 Hz 至 1 kHz","range":"1 A 至 3 A","cmc":"0,09 % + 3 mA"},{"name":"20 Hz 至 1 kHz","range":"3 A 至 10 A","cmc":"0,2 % + 7 mA"}],"parameters_cs":[{"name":"20 Hz až 1 kHz","range":"10 µA až 100 µA","cmc":"0,2 µA"},{"name":"20 Hz až 1 kHz","range":"100 µA až 1 mA","cmc":"0,08 % + 0,4 µA"},{"name":"20 Hz až 1 kHz","range":"1 mA až 10 mA","cmc":"0,2 % + 5 µA"},{"name":"20 Hz až 1 kHz","range":"10 mA až 100 mA","cmc":"0,07 % + 40 µA"},{"name":"20 Hz až 1 kHz","range":"100 mA až 400 mA","cmc":"0,2 % + 0,4 mA"},{"name":"20 Hz až 1 kHz","range":"400 mA až 1 A","cmc":"0,07 % + 0,7 mA"},{"name":"20 Hz až 1 kHz","range":"1 A až 3 A","cmc":"0,09 % + 3 mA"},{"name":"20 Hz až 1 kHz","range":"3 A až 10 A","cmc":"0,2 % + 7 mA"}],"technique":"Pomiar bezpośredni multimetrem wzorcowym","technique_en":"Direct measurement by a standard multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Pomiar bezpośredni multimetrem wzorcowym"],"techniques_en":["Direct measurement by a standard multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n20 Hz do 1 kHz od 10 µA do 100 µA CMC 0,2 µA\n20 Hz do 1 kHz od 100 µA do 1 mA CMC 0,08 % + 0,4 µA\n20 Hz do 1 kHz od 1 mA do 10 mA CMC 0,2 % + 5 µA\n20 Hz do 1 kHz od 10 mA do 100 mA CMC 0,07 % + 40 µA\n20 Hz do 1 kHz od 100 mA do 400 mA CMC 0,2 % + 0,4 mA\n20 Hz do 1 kHz od 400 mA do 1 A CMC 0,07 % + 0,7 mA\n20 Hz do 1 kHz od 1 A do 3 A CMC 0,09 % + 3 mA\n20 Hz do 1 kHz od 3 A do 10 A CMC 0,2 % + 7 mA\nPomiar bezpośredni multimetrem wzorcowym","reference":"KA-04","norm_bases":["KA-04"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / źródła prądu przemiennego, testery wielofunkcyjne Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem wzorcowym 20 Hz do 1 kHz od 10 µA do 100 µA CMC 0,2 µA 20 Hz do 1 kHz od 100 µA do 1 mA CMC 0,08 % + 0,4 µA 20 Hz do 1 kHz od 1 mA do 10 mA CMC 0,2 % + 5 µA 20 Hz do 1 kHz od 10 mA do 100 mA CMC 0,07 % + 40 µA 20 Hz do 1 kHz od 100 mA do 400 mA CMC 0,2 % + 0,4 mA 20 Hz do 1 kHz od 400 mA do 1 A CMC 0,07 % + 0,7 mA 20 Hz do 1 kHz od 1 A do 3 A CMC 0,09 % + 3 mA 20 Hz do 1 kHz od 3 A do 10 A CMC 0,2 % + 7 mA Střídavý proud / zdroje střídavého proudu, multifunkční testery Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem 20 Hz až 1 kHz 10 µA až 100 µA CMC 0,2 µA 20 Hz až 1 kHz 100 µA až 1 mA CMC 0,08 % + 0,4 µA 20 Hz až 1 kHz 1 mA až 10 mA CMC 0,2 % + 5 µA 20 Hz až 1 kHz 10 mA až 100 mA CMC 0,07 % + 40 µA 20 Hz až 1 kHz 100 mA až 400 mA CMC 0,2 % + 0,4 mA 20 Hz až 1 kHz 400 mA až 1 A CMC 0,07 % + 0,7 mA 20 Hz až 1 kHz 1 A až 3 A CMC 0,09 % + 3 mA 20 Hz až 1 kHz 3 A až 10 A CMC 0,2 % + 7 mA KA-04 Prad przemienny / zrodla pradu przemiennego, testery wielofunkcyjne Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem wzorcowym 20 Hz do 1 kHz od 10 µA do 100 µA CMC 0,2 µA 20 Hz do 1 kHz od 100 µA do 1 mA CMC 0,08 % + 0,4 µA 20 Hz do 1 kHz od 1 mA do 10 mA CMC 0,2 % + 5 µA 20 Hz do 1 kHz od 10 mA do 100 mA CMC 0,07 % + 40 µA 20 Hz do 1 kHz od 100 mA do 400 mA CMC 0,2 % + 0,4 mA 20 Hz do 1 kHz od 400 mA do 1 A CMC 0,07 % + 0,7 mA 20 Hz do 1 kHz od 1 A do 3 A CMC 0,09 % + 3 mA 20 Hz do 1 kHz od 3 A do 10 A CMC 0,2 % + 7 mA Stridavy proud / zdroje stridaveho proudu, multifunkcni testery Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem 20 Hz az 1 kHz 10 µA az 100 µA CMC 0,2 µA 20 Hz az 1 kHz 100 µA az 1 mA CMC 0,08 % + 0,4 µA 20 Hz az 1 kHz 1 mA az 10 mA CMC 0,2 % + 5 µA 20 Hz az 1 kHz 10 mA az 100 mA CMC 0,07 % + 40 µA 20 Hz az 1 kHz 100 mA az 400 mA CMC 0,2 % + 0,4 mA 20 Hz az 1 kHz 400 mA az 1 A CMC 0,07 % + 0,7 mA 20 Hz az 1 kHz 1 A az 3 A CMC 0,09 % + 3 mA 20 Hz az 1 kHz 3 A az 10 A CMC 0,2 % + 7 mA KA-04","search_en":"AC current / AC current sources, multifunction testers Calibration – electrical quantities Direct measurement by a standard multimeter 20 Hz to 1 kHz 10 µA to 100 µA CMC 0,2 µA 20 Hz to 1 kHz 100 µA to 1 mA CMC 0,08 % + 0,4 µA 20 Hz to 1 kHz 1 mA to 10 mA CMC 0,2 % + 5 µA 20 Hz to 1 kHz 10 mA to 100 mA CMC 0,07 % + 40 µA 20 Hz to 1 kHz 100 mA to 400 mA CMC 0,2 % + 0,4 mA 20 Hz to 1 kHz 400 mA to 1 A CMC 0,07 % + 0,7 mA 20 Hz to 1 kHz 1 A to 3 A CMC 0,09 % + 3 mA 20 Hz to 1 kHz 3 A to 10 A CMC 0,2 % + 7 mA KA-04","search_zh":"交流电流 / 交流电流源、多功能测试仪 校准 – 电学量 用标准万用表直接测量 20 Hz 至 1 kHz 10 µA 至 100 µA CMC 0,2 µA 20 Hz 至 1 kHz 100 µA 至 1 mA CMC 0,08 % + 0,4 µA 20 Hz 至 1 kHz 1 mA 至 10 mA CMC 0,2 % + 5 µA 20 Hz 至 1 kHz 10 mA 至 100 mA CMC 0,07 % + 40 µA 20 Hz 至 1 kHz 100 mA 至 400 mA CMC 0,2 % + 0,4 mA 20 Hz 至 1 kHz 400 mA 至 1 A CMC 0,07 % + 0,7 mA 20 Hz 至 1 kHz 1 A 至 3 A CMC 0,09 % + 3 mA 20 Hz 至 1 kHz 3 A 至 10 A CMC 0,2 % + 7 mA KA-04","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"455753790825e6bba50b1fab","lab_id":"6ade8b57ff0682476170814c","country":"CZ","accr_number":"2417","accr_body":"ČIA","row_label":"4","test_object":"Prąd przemienny / źródła prądu przemiennego, testery wielofunkcyjne","test_object_en":"AC current / AC current sources, multifunction testers","test_object_zh":"交流电流 / 交流电流源、多功能测试仪","test_object_cs":"Střídavý proud / zdroje střídavého proudu, multifunkční testery","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz do 60 Hz","range":"od 10 A do 30 A","cmc":"0,31 % + 18 mA"},{"name":"50 Hz do 60 Hz","range":"od 30 A do 100 A","cmc":"1,3 % + 24 mA"}],"parameters_en":[{"name":"50 Hz to 60 Hz","range":"10 A to 30 A","cmc":"0,31 % + 18 mA"},{"name":"50 Hz to 60 Hz","range":"30 A to 100 A","cmc":"1,3 % + 24 mA"}],"parameters_zh":[{"name":"50 Hz 至 60 Hz","range":"10 A 至 30 A","cmc":"0,31 % + 18 mA"},{"name":"50 Hz 至 60 Hz","range":"30 A 至 100 A","cmc":"1,3 % + 24 mA"}],"parameters_cs":[{"name":"50 Hz až 60 Hz","range":"10 A až 30 A","cmc":"0,31 % + 18 mA"},{"name":"50 Hz až 60 Hz","range":"30 A až 100 A","cmc":"1,3 % + 24 mA"}],"technique":"Pomiar multimetrem wzorcowym z cęgami prądowymi","technique_en":"Measurement by a reference multimeter with current clamps","technique_zh":"用带电流钳的标准万用表测量","technique_cs":"Měření etalonovým multimetrem s proudovými kleštěmi","techniques":["Pomiar multimetrem wzorcowym z cęgami prądowymi"],"techniques_en":["Measurement by a reference multimeter with current clamps"],"techniques_zh":["用带电流钳的标准万用表测量"],"techniques_cs":["Měření etalonovým multimetrem s proudovými kleštěmi"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n50 Hz do 60 Hz od 10 A do 30 A CMC 0,31 % + 18 mA\n50 Hz do 60 Hz od 30 A do 100 A CMC 1,3 % + 24 mA\nPomiar multimetrem wzorcowym z cęgami prądowymi","reference":"KA-04","norm_bases":["KA-04"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / źródła prądu przemiennego, testery wielofunkcyjne Wzorcowanie – wielkości elektryczne Pomiar multimetrem wzorcowym z cęgami prądowymi 50 Hz do 60 Hz od 10 A do 30 A CMC 0,31 % + 18 mA 50 Hz do 60 Hz od 30 A do 100 A CMC 1,3 % + 24 mA Střídavý proud / zdroje střídavého proudu, multifunkční testery Kalibrace – elektrické veličiny Měření etalonovým multimetrem s proudovými kleštěmi 50 Hz až 60 Hz 10 A až 30 A CMC 0,31 % + 18 mA 50 Hz až 60 Hz 30 A až 100 A CMC 1,3 % + 24 mA KA-04 Prad przemienny / zrodla pradu przemiennego, testery wielofunkcyjne Wzorcowanie – wielkosci elektryczne Pomiar multimetrem wzorcowym z cegami pradowymi 50 Hz do 60 Hz od 10 A do 30 A CMC 0,31 % + 18 mA 50 Hz do 60 Hz od 30 A do 100 A CMC 1,3 % + 24 mA Stridavy proud / zdroje stridaveho proudu, multifunkcni testery Kalibrace – elektricke veliciny Mereni etalonovym multimetrem s proudovymi klestemi 50 Hz az 60 Hz 10 A az 30 A CMC 0,31 % + 18 mA 50 Hz az 60 Hz 30 A az 100 A CMC 1,3 % + 24 mA KA-04","search_en":"AC current / AC current sources, multifunction testers Calibration – electrical quantities Measurement by a reference multimeter with current clamps 50 Hz to 60 Hz 10 A to 30 A CMC 0,31 % + 18 mA 50 Hz to 60 Hz 30 A to 100 A CMC 1,3 % + 24 mA KA-04","search_zh":"交流电流 / 交流电流源、多功能测试仪 校准 – 电学量 用带电流钳的标准万用表测量 50 Hz 至 60 Hz 10 A 至 30 A CMC 0,31 % + 18 mA 50 Hz 至 60 Hz 30 A 至 100 A CMC 1,3 % + 24 mA KA-04","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"92e001ff94cab03998f920ef","lab_id":"6ade8b57ff0682476170814c","country":"CZ","accr_number":"2417","accr_body":"ČIA","row_label":"5","test_object":"Rezystancja przy prądzie stałym / rezystory","test_object_en":"DC resistance / resistors","test_object_zh":"直流电阻 / 电阻器","test_object_cs":"Stejnosměrný odpor / odpory","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 1 mΩ do 50 mΩ","cmc":"0,2 % + 20 µΩ"},{"name":"","range":"od 50 mΩ do 500 mΩ","cmc":"0,06 % + 0,2 mΩ"},{"name":"","range":"od 500 mΩ do 3 Ω","cmc":"0,06 % + 2 mΩ"}],"parameters_en":[{"name":"","range":"1 mΩ to 50 mΩ","cmc":"0,2 % + 20 µΩ"},{"name":"","range":"50 mΩ to 500 mΩ","cmc":"0,06 % + 0,2 mΩ"},{"name":"","range":"500 mΩ to 3 Ω","cmc":"0,06 % + 2 mΩ"}],"parameters_zh":[{"name":"","range":"1 mΩ 至 50 mΩ","cmc":"0,2 % + 20 µΩ"},{"name":"","range":"50 mΩ 至 500 mΩ","cmc":"0,06 % + 0,2 mΩ"},{"name":"","range":"500 mΩ 至 3 Ω","cmc":"0,06 % + 2 mΩ"}],"parameters_cs":[{"name":"","range":"1 mΩ až 50 mΩ","cmc":"0,2 % + 20 µΩ"},{"name":"","range":"50 mΩ až 500 mΩ","cmc":"0,06 % + 0,2 mΩ"},{"name":"","range":"500 mΩ až 3 Ω","cmc":"0,06 % + 2 mΩ"}],"technique":"Pomiar bezpośredni miliomomierzem wzorcowym","technique_en":"Direct measurement by a reference milliohmmeter","technique_zh":"用标准毫欧表直接测量","technique_cs":"Přímé měření etalonovým miliohmmetrem","techniques":["Pomiar bezpośredni miliomomierzem wzorcowym"],"techniques_en":["Direct measurement by a reference milliohmmeter"],"techniques_zh":["用标准毫欧表直接测量"],"techniques_cs":["Přímé měření etalonovým miliohmmetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 1 mΩ do 50 mΩ CMC 0,2 % + 20 µΩ\nod 50 mΩ do 500 mΩ CMC 0,06 % + 0,2 mΩ\nod 500 mΩ do 3 Ω CMC 0,06 % + 2 mΩ\nPomiar bezpośredni miliomomierzem wzorcowym","reference":"KA-05","norm_bases":["KA-05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / rezystory Wzorcowanie – wielkości elektryczne Pomiar bezpośredni miliomomierzem wzorcowym od 1 mΩ do 50 mΩ CMC 0,2 % + 20 µΩ od 50 mΩ do 500 mΩ CMC 0,06 % + 0,2 mΩ od 500 mΩ do 3 Ω CMC 0,06 % + 2 mΩ Stejnosměrný odpor / odpory Kalibrace – elektrické veličiny Přímé měření etalonovým miliohmmetrem 1 mΩ až 50 mΩ CMC 0,2 % + 20 µΩ 50 mΩ až 500 mΩ CMC 0,06 % + 0,2 mΩ 500 mΩ až 3 Ω CMC 0,06 % + 2 mΩ KA-05 Rezystancja przy pradzie stalym / rezystory Wzorcowanie – wielkosci elektryczne Pomiar bezposredni miliomomierzem wzorcowym od 1 mΩ do 50 mΩ CMC 0,2 % + 20 µΩ od 50 mΩ do 500 mΩ CMC 0,06 % + 0,2 mΩ od 500 mΩ do 3 Ω CMC 0,06 % + 2 mΩ Stejnosmerny odpor / odpory Kalibrace – elektricke veliciny Prime mereni etalonovym miliohmmetrem 1 mΩ az 50 mΩ CMC 0,2 % + 20 µΩ 50 mΩ az 500 mΩ CMC 0,06 % + 0,2 mΩ 500 mΩ az 3 Ω CMC 0,06 % + 2 mΩ KA-05","search_en":"DC resistance / resistors Calibration – electrical quantities Direct measurement by a reference milliohmmeter 1 mΩ to 50 mΩ CMC 0,2 % + 20 µΩ 50 mΩ to 500 mΩ CMC 0,06 % + 0,2 mΩ 500 mΩ to 3 Ω CMC 0,06 % + 2 mΩ KA-05","search_zh":"直流电阻 / 电阻器 校准 – 电学量 用标准毫欧表直接测量 1 mΩ 至 50 mΩ CMC 0,2 % + 20 µΩ 50 mΩ 至 500 mΩ CMC 0,06 % + 0,2 mΩ 500 mΩ 至 3 Ω CMC 0,06 % + 2 mΩ KA-05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e544b9d1f2dede86b0119562","lab_id":"6ade8b57ff0682476170814c","country":"CZ","accr_number":"2417","accr_body":"ČIA","row_label":"5","test_object":"Rezystancja przy prądzie stałym / rezystory","test_object_en":"DC resistance / resistors","test_object_zh":"直流电阻 / 电阻器","test_object_cs":"Stejnosměrný odpor / odpory","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 3 Ω do 10 Ω","cmc":"0,008 % + 3 mΩ"},{"name":"","range":"od 10 Ω do 100 Ω","cmc":"0,008 % + 4 mΩ"},{"name":"","range":"od 100 Ω do 1 kΩ","cmc":"0,008 % + 8 mΩ"},{"name":"","range":"od 1 kΩ do 10 kΩ","cmc":"0,008 % + 0,08 Ω"},{"name":"","range":"od 10 kΩ do 100 kΩ","cmc":"0,008 % + 0,8 Ω"},{"name":"","range":"od 100 kΩ do 1 MΩ","cmc":"0,008 % + 8 Ω"},{"name":"","range":"od 1 MΩ do 10 MΩ","cmc":"0,04 % + 80 Ω"},{"name":"","range":"od 10 MΩ do 100 MΩ","cmc":"0,6 % + 7 kΩ"},{"name":"","range":"od 100 MΩ do 1 GΩ","cmc":"2 % + 80 kΩ"}],"parameters_en":[{"name":"","range":"3 Ω to 10 Ω","cmc":"0,008 % + 3 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"0,008 % + 4 mΩ"},{"name":"","range":"100 Ω to 1 kΩ","cmc":"0,008 % + 8 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,008 % + 0,08 Ω"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,008 % + 0,8 Ω"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"0,008 % + 8 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,04 % + 80 Ω"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,6 % + 7 kΩ"},{"name":"","range":"100 MΩ to 1 GΩ","cmc":"2 % + 80 kΩ"}],"parameters_zh":[{"name":"","range":"3 Ω 至 10 Ω","cmc":"0,008 % + 3 mΩ"},{"name":"","range":"10 Ω 至 100 Ω","cmc":"0,008 % + 4 mΩ"},{"name":"","range":"100 Ω 至 1 kΩ","cmc":"0,008 % + 8 mΩ"},{"name":"","range":"1 kΩ 至 10 kΩ","cmc":"0,008 % + 0,08 Ω"},{"name":"","range":"10 kΩ 至 100 kΩ","cmc":"0,008 % + 0,8 Ω"},{"name":"","range":"100 kΩ 至 1 MΩ","cmc":"0,008 % + 8 Ω"},{"name":"","range":"1 MΩ 至 10 MΩ","cmc":"0,04 % + 80 Ω"},{"name":"","range":"10 MΩ 至 100 MΩ","cmc":"0,6 % + 7 kΩ"},{"name":"","range":"100 MΩ 至 1 GΩ","cmc":"2 % + 80 kΩ"}],"parameters_cs":[{"name":"","range":"3 Ω až 10 Ω","cmc":"0,008 % + 3 mΩ"},{"name":"","range":"10 Ω až 100 Ω","cmc":"0,008 % + 4 mΩ"},{"name":"","range":"100 Ω až 1 kΩ","cmc":"0,008 % + 8 mΩ"},{"name":"","range":"1 kΩ až 10 kΩ","cmc":"0,008 % + 0,08 Ω"},{"name":"","range":"10 kΩ až 100 kΩ","cmc":"0,008 % + 0,8 Ω"},{"name":"","range":"100 kΩ až 1 MΩ","cmc":"0,008 % + 8 Ω"},{"name":"","range":"1 MΩ až 10 MΩ","cmc":"0,04 % + 80 Ω"},{"name":"","range":"10 MΩ až 100 MΩ","cmc":"0,6 % + 7 kΩ"},{"name":"","range":"100 MΩ až 1 GΩ","cmc":"2 % + 80 kΩ"}],"technique":"Pomiar bezpośredni multimetrem wzorcowym","technique_en":"Direct measurement by a standard multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Pomiar bezpośredni multimetrem wzorcowym"],"techniques_en":["Direct measurement by a standard multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 3 Ω do 10 Ω CMC 0,008 % + 3 mΩ\nod 10 Ω do 100 Ω CMC 0,008 % + 4 mΩ\nod 100 Ω do 1 kΩ CMC 0,008 % + 8 mΩ\nod 1 kΩ do 10 kΩ CMC 0,008 % + 0,08 Ω\nod 10 kΩ do 100 kΩ CMC 0,008 % + 0,8 Ω\nod 100 kΩ do 1 MΩ CMC 0,008 % + 8 Ω\nod 1 MΩ do 10 MΩ CMC 0,04 % + 80 Ω\nod 10 MΩ do 100 MΩ CMC 0,6 % + 7 kΩ\nod 100 MΩ do 1 GΩ CMC 2 % + 80 kΩ\nPomiar bezpośredni multimetrem wzorcowym","reference":"KA-05","norm_bases":["KA-05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / rezystory Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem wzorcowym od 3 Ω do 10 Ω CMC 0,008 % + 3 mΩ od 10 Ω do 100 Ω CMC 0,008 % + 4 mΩ od 100 Ω do 1 kΩ CMC 0,008 % + 8 mΩ od 1 kΩ do 10 kΩ CMC 0,008 % + 0,08 Ω od 10 kΩ do 100 kΩ CMC 0,008 % + 0,8 Ω od 100 kΩ do 1 MΩ CMC 0,008 % + 8 Ω od 1 MΩ do 10 MΩ CMC 0,04 % + 80 Ω od 10 MΩ do 100 MΩ CMC 0,6 % + 7 kΩ od 100 MΩ do 1 GΩ CMC 2 % + 80 kΩ Stejnosměrný odpor / odpory Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem 3 Ω až 10 Ω CMC 0,008 % + 3 mΩ 10 Ω až 100 Ω CMC 0,008 % + 4 mΩ 100 Ω až 1 kΩ CMC 0,008 % + 8 mΩ 1 kΩ až 10 kΩ CMC 0,008 % + 0,08 Ω 10 kΩ až 100 kΩ CMC 0,008 % + 0,8 Ω 100 kΩ až 1 MΩ CMC 0,008 % + 8 Ω 1 MΩ až 10 MΩ CMC 0,04 % + 80 Ω 10 MΩ až 100 MΩ CMC 0,6 % + 7 kΩ 100 MΩ až 1 GΩ CMC 2 % + 80 kΩ KA-05 Rezystancja przy pradzie stalym / rezystory Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem wzorcowym od 3 Ω do 10 Ω CMC 0,008 % + 3 mΩ od 10 Ω do 100 Ω CMC 0,008 % + 4 mΩ od 100 Ω do 1 kΩ CMC 0,008 % + 8 mΩ od 1 kΩ do 10 kΩ CMC 0,008 % + 0,08 Ω od 10 kΩ do 100 kΩ CMC 0,008 % + 0,8 Ω od 100 kΩ do 1 MΩ CMC 0,008 % + 8 Ω od 1 MΩ do 10 MΩ CMC 0,04 % + 80 Ω od 10 MΩ do 100 MΩ CMC 0,6 % + 7 kΩ od 100 MΩ do 1 GΩ CMC 2 % + 80 kΩ Stejnosmerny odpor / odpory Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem 3 Ω az 10 Ω CMC 0,008 % + 3 mΩ 10 Ω az 100 Ω CMC 0,008 % + 4 mΩ 100 Ω az 1 kΩ CMC 0,008 % + 8 mΩ 1 kΩ az 10 kΩ CMC 0,008 % + 0,08 Ω 10 kΩ az 100 kΩ CMC 0,008 % + 0,8 Ω 100 kΩ az 1 MΩ CMC 0,008 % + 8 Ω 1 MΩ az 10 MΩ CMC 0,04 % + 80 Ω 10 MΩ az 100 MΩ CMC 0,6 % + 7 kΩ 100 MΩ az 1 GΩ CMC 2 % + 80 kΩ KA-05","search_en":"DC resistance / resistors Calibration – electrical quantities Direct measurement by a standard multimeter 3 Ω to 10 Ω CMC 0,008 % + 3 mΩ 10 Ω to 100 Ω CMC 0,008 % + 4 mΩ 100 Ω to 1 kΩ CMC 0,008 % + 8 mΩ 1 kΩ to 10 kΩ CMC 0,008 % + 0,08 Ω 10 kΩ to 100 kΩ CMC 0,008 % + 0,8 Ω 100 kΩ to 1 MΩ CMC 0,008 % + 8 Ω 1 MΩ to 10 MΩ CMC 0,04 % + 80 Ω 10 MΩ to 100 MΩ CMC 0,6 % + 7 kΩ 100 MΩ to 1 GΩ CMC 2 % + 80 kΩ KA-05","search_zh":"直流电阻 / 电阻器 校准 – 电学量 用标准万用表直接测量 3 Ω 至 10 Ω CMC 0,008 % + 3 mΩ 10 Ω 至 100 Ω CMC 0,008 % + 4 mΩ 100 Ω 至 1 kΩ CMC 0,008 % + 8 mΩ 1 kΩ 至 10 kΩ CMC 0,008 % + 0,08 Ω 10 kΩ 至 100 kΩ CMC 0,008 % + 0,8 Ω 100 kΩ 至 1 MΩ CMC 0,008 % + 8 Ω 1 MΩ 至 10 MΩ CMC 0,04 % + 80 Ω 10 MΩ 至 100 MΩ CMC 0,6 % + 7 kΩ 100 MΩ 至 1 GΩ CMC 2 % + 80 kΩ KA-05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1f687388a441396068d7ef77","lab_id":"6ade8b57ff0682476170814c","country":"CZ","accr_number":"2417","accr_body":"ČIA","row_label":"6","test_object":"Rezystancja przewodu ochronnego / testery wielofunkcyjne","test_object_en":"Protective conductor resistance / multifunction testers","test_object_zh":"保护导体电阻 / 多功能测试仪","test_object_cs":"Odpor ochranného vodiče / multifunkční testery","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"50 mΩ","cmc":"1,2 mΩ"},{"name":"","range":"100 mΩ","cmc":"1,2 mΩ"},{"name":"","range":"200 mΩ","cmc":"1,5 mΩ"},{"name":"","range":"300 mΩ","cmc":"2 mΩ"},{"name":"","range":"400 mΩ","cmc":"2 mΩ"},{"name":"","range":"1 Ω","cmc":"5 mΩ"}],"parameters_en":[{"name":"","range":"50 mΩ","cmc":"1,2 mΩ"},{"name":"","range":"100 mΩ","cmc":"1,2 mΩ"},{"name":"","range":"200 mΩ","cmc":"1,5 mΩ"},{"name":"","range":"300 mΩ","cmc":"2 mΩ"},{"name":"","range":"400 mΩ","cmc":"2 mΩ"},{"name":"","range":"1 Ω","cmc":"5 mΩ"}],"parameters_zh":[{"name":"","range":"50 mΩ","cmc":"1,2 mΩ"},{"name":"","range":"100 mΩ","cmc":"1,2 mΩ"},{"name":"","range":"200 mΩ","cmc":"1,5 mΩ"},{"name":"","range":"300 mΩ","cmc":"2 mΩ"},{"name":"","range":"400 mΩ","cmc":"2 mΩ"},{"name":"","range":"1 Ω","cmc":"5 mΩ"}],"parameters_cs":[{"name":"","range":"50 mΩ","cmc":"1,2 mΩ"},{"name":"","range":"100 mΩ","cmc":"1,2 mΩ"},{"name":"","range":"200 mΩ","cmc":"1,5 mΩ"},{"name":"","range":"300 mΩ","cmc":"2 mΩ"},{"name":"","range":"400 mΩ","cmc":"2 mΩ"},{"name":"","range":"1 Ω","cmc":"5 mΩ"}],"technique":"Pomiar bezpośredni rezystorów wzorcowych","technique_en":"Direct measurement of resistance standards","technique_zh":"直接测量标准电阻","technique_cs":"Přímé měření etalonových odporů","techniques":["Pomiar bezpośredni rezystorów wzorcowych"],"techniques_en":["Direct measurement of resistance standards"],"techniques_zh":["直接测量标准电阻"],"techniques_cs":["Přímé měření etalonových odporů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n50 mΩ CMC 1,2 mΩ\n100 mΩ CMC 1,2 mΩ\n200 mΩ CMC 1,5 mΩ\n300 mΩ CMC 2 mΩ\n400 mΩ CMC 2 mΩ\n1 Ω CMC 5 mΩ\nPomiar bezpośredni rezystorów wzorcowych","reference":"KA-07","norm_bases":["KA-07"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przewodu ochronnego / testery wielofunkcyjne Wzorcowanie – wielkości elektryczne Pomiar bezpośredni rezystorów wzorcowych 50 mΩ CMC 1,2 mΩ 100 mΩ CMC 1,2 mΩ 200 mΩ CMC 1,5 mΩ 300 mΩ CMC 2 mΩ 400 mΩ CMC 2 mΩ 1 Ω CMC 5 mΩ Odpor ochranného vodiče / multifunkční testery Kalibrace – elektrické veličiny Přímé měření etalonových odporů 50 mΩ CMC 1,2 mΩ 100 mΩ CMC 1,2 mΩ 200 mΩ CMC 1,5 mΩ 300 mΩ CMC 2 mΩ 400 mΩ CMC 2 mΩ 1 Ω CMC 5 mΩ KA-07 Rezystancja przewodu ochronnego / testery wielofunkcyjne Wzorcowanie – wielkosci elektryczne Pomiar bezposredni rezystorow wzorcowych 50 mΩ CMC 1,2 mΩ 100 mΩ CMC 1,2 mΩ 200 mΩ CMC 1,5 mΩ 300 mΩ CMC 2 mΩ 400 mΩ CMC 2 mΩ 1 Ω CMC 5 mΩ Odpor ochranneho vodice / multifunkcni testery Kalibrace – elektricke veliciny Prime mereni etalonovych odporu 50 mΩ CMC 1,2 mΩ 100 mΩ CMC 1,2 mΩ 200 mΩ CMC 1,5 mΩ 300 mΩ CMC 2 mΩ 400 mΩ CMC 2 mΩ 1 Ω CMC 5 mΩ KA-07","search_en":"Protective conductor resistance / multifunction testers Calibration – electrical quantities Direct measurement of resistance standards 50 mΩ CMC 1,2 mΩ 100 mΩ CMC 1,2 mΩ 200 mΩ CMC 1,5 mΩ 300 mΩ CMC 2 mΩ 400 mΩ CMC 2 mΩ 1 Ω CMC 5 mΩ KA-07","search_zh":"保护导体电阻 / 多功能测试仪 校准 – 电学量 直接测量标准电阻 50 mΩ CMC 1,2 mΩ 100 mΩ CMC 1,2 mΩ 200 mΩ CMC 1,5 mΩ 300 mΩ CMC 2 mΩ 400 mΩ CMC 2 mΩ 1 Ω CMC 5 mΩ KA-07","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7cf8a4ed84ad7587ab32a238","lab_id":"6ade8b57ff0682476170814c","country":"CZ","accr_number":"2417","accr_body":"ČIA","row_label":"7","test_object":"Rezystancja izolacji / mierniki rezystancji izolacji, testery wielofunkcyjne","test_object_en":"Insulation resistance / insulation resistance meters, multifunction testers","test_object_zh":"绝缘电阻 / 绝缘电阻测量仪、多功能测试仪","test_object_cs":"Izolační odpor / měřidla izolačního odporu, multifunkční testery","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"0,5 MΩ","cmc":"6 kΩ"},{"name":"","range":"1 MΩ","cmc":"12 kΩ"},{"name":"","range":"2 MΩ","cmc":"24 kΩ"},{"name":"","range":"3 MΩ","cmc":"36 kΩ"},{"name":"","range":"5 MΩ","cmc":"59 kΩ"},{"name":"","range":"9 MΩ","cmc":"110 kΩ"},{"name":"","range":"10 MΩ","cmc":"120 kΩ"},{"name":"","range":"20 MΩ","cmc":"240 kΩ"},{"name":"","range":"30 MΩ","cmc":"360 kΩ"},{"name":"","range":"45 MΩ","cmc":"0,53 MΩ"},{"name":"","range":"50 MΩ","cmc":"0,63 MΩ"},{"name":"","range":"90 MΩ","cmc":"1,1 MΩ"},{"name":"","range":"220 MΩ","cmc":"3,8 MΩ"},{"name":"","range":"450 MΩ","cmc":"8,4 MΩ"},{"name":"","range":"900 MΩ","cmc":"11 MΩ"}],"parameters_en":[{"name":"","range":"0,5 MΩ","cmc":"6 kΩ"},{"name":"","range":"1 MΩ","cmc":"12 kΩ"},{"name":"","range":"2 MΩ","cmc":"24 kΩ"},{"name":"","range":"3 MΩ","cmc":"36 kΩ"},{"name":"","range":"5 MΩ","cmc":"59 kΩ"},{"name":"","range":"9 MΩ","cmc":"110 kΩ"},{"name":"","range":"10 MΩ","cmc":"120 kΩ"},{"name":"","range":"20 MΩ","cmc":"240 kΩ"},{"name":"","range":"30 MΩ","cmc":"360 kΩ"},{"name":"","range":"45 MΩ","cmc":"0,53 MΩ"},{"name":"","range":"50 MΩ","cmc":"0,63 MΩ"},{"name":"","range":"90 MΩ","cmc":"1,1 MΩ"},{"name":"","range":"220 MΩ","cmc":"3,8 MΩ"},{"name":"","range":"450 MΩ","cmc":"8,4 MΩ"},{"name":"","range":"900 MΩ","cmc":"11 MΩ"}],"parameters_zh":[{"name":"","range":"0,5 MΩ","cmc":"6 kΩ"},{"name":"","range":"1 MΩ","cmc":"12 kΩ"},{"name":"","range":"2 MΩ","cmc":"24 kΩ"},{"name":"","range":"3 MΩ","cmc":"36 kΩ"},{"name":"","range":"5 MΩ","cmc":"59 kΩ"},{"name":"","range":"9 MΩ","cmc":"110 kΩ"},{"name":"","range":"10 MΩ","cmc":"120 kΩ"},{"name":"","range":"20 MΩ","cmc":"240 kΩ"},{"name":"","range":"30 MΩ","cmc":"360 kΩ"},{"name":"","range":"45 MΩ","cmc":"0,53 MΩ"},{"name":"","range":"50 MΩ","cmc":"0,63 MΩ"},{"name":"","range":"90 MΩ","cmc":"1,1 MΩ"},{"name":"","range":"220 MΩ","cmc":"3,8 MΩ"},{"name":"","range":"450 MΩ","cmc":"8,4 MΩ"},{"name":"","range":"900 MΩ","cmc":"11 MΩ"}],"parameters_cs":[{"name":"","range":"0,5 MΩ","cmc":"6 kΩ"},{"name":"","range":"1 MΩ","cmc":"12 kΩ"},{"name":"","range":"2 MΩ","cmc":"24 kΩ"},{"name":"","range":"3 MΩ","cmc":"36 kΩ"},{"name":"","range":"5 MΩ","cmc":"59 kΩ"},{"name":"","range":"9 MΩ","cmc":"110 kΩ"},{"name":"","range":"10 MΩ","cmc":"120 kΩ"},{"name":"","range":"20 MΩ","cmc":"240 kΩ"},{"name":"","range":"30 MΩ","cmc":"360 kΩ"},{"name":"","range":"45 MΩ","cmc":"0,53 MΩ"},{"name":"","range":"50 MΩ","cmc":"0,63 MΩ"},{"name":"","range":"90 MΩ","cmc":"1,1 MΩ"},{"name":"","range":"220 MΩ","cmc":"3,8 MΩ"},{"name":"","range":"450 MΩ","cmc":"8,4 MΩ"},{"name":"","range":"900 MΩ","cmc":"11 MΩ"}],"technique":"Pomiar bezpośredni rezystorów wzorcowych","technique_en":"Direct measurement of resistance standards","technique_zh":"直接测量标准电阻","technique_cs":"Přímé měření etalonových odporů","techniques":["Pomiar bezpośredni rezystorów wzorcowych"],"techniques_en":["Direct measurement of resistance standards"],"techniques_zh":["直接测量标准电阻"],"techniques_cs":["Přímé měření etalonových odporů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n0,5 MΩ CMC 6 kΩ\n1 MΩ CMC 12 kΩ\n2 MΩ CMC 24 kΩ\n3 MΩ CMC 36 kΩ\n5 MΩ CMC 59 kΩ\n9 MΩ CMC 110 kΩ\n10 MΩ CMC 120 kΩ\n20 MΩ CMC 240 kΩ\n30 MΩ CMC 360 kΩ\n45 MΩ CMC 0,53 MΩ\n50 MΩ CMC 0,63 MΩ\n90 MΩ CMC 1,1 MΩ\n220 MΩ CMC 3,8 MΩ\n450 MΩ CMC 8,4 MΩ\n900 MΩ CMC 11 MΩ\nPomiar bezpośredni rezystorów wzorcowych","reference":"KA-06","norm_bases":["KA-06"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja izolacji / mierniki rezystancji izolacji, testery wielofunkcyjne Wzorcowanie – wielkości elektryczne Pomiar bezpośredni rezystorów wzorcowych 0,5 MΩ CMC 6 kΩ 1 MΩ CMC 12 kΩ 2 MΩ CMC 24 kΩ 3 MΩ CMC 36 kΩ 5 MΩ CMC 59 kΩ 9 MΩ CMC 110 kΩ 10 MΩ CMC 120 kΩ 20 MΩ CMC 240 kΩ 30 MΩ CMC 360 kΩ 45 MΩ CMC 0,53 MΩ 50 MΩ CMC 0,63 MΩ 90 MΩ CMC 1,1 MΩ 220 MΩ CMC 3,8 MΩ 450 MΩ CMC 8,4 MΩ 900 MΩ CMC 11 MΩ Izolační odpor / měřidla izolačního odporu, multifunkční testery Kalibrace – elektrické veličiny Přímé měření etalonových odporů 0,5 MΩ CMC 6 kΩ 1 MΩ CMC 12 kΩ 2 MΩ CMC 24 kΩ 3 MΩ CMC 36 kΩ 5 MΩ CMC 59 kΩ 9 MΩ CMC 110 kΩ 10 MΩ CMC 120 kΩ 20 MΩ CMC 240 kΩ 30 MΩ CMC 360 kΩ 45 MΩ CMC 0,53 MΩ 50 MΩ CMC 0,63 MΩ 90 MΩ CMC 1,1 MΩ 220 MΩ CMC 3,8 MΩ 450 MΩ CMC 8,4 MΩ 900 MΩ CMC 11 MΩ KA-06 Rezystancja izolacji / mierniki rezystancji izolacji, testery wielofunkcyjne Wzorcowanie – wielkosci elektryczne Pomiar bezposredni rezystorow wzorcowych 0,5 MΩ CMC 6 kΩ 1 MΩ CMC 12 kΩ 2 MΩ CMC 24 kΩ 3 MΩ CMC 36 kΩ 5 MΩ CMC 59 kΩ 9 MΩ CMC 110 kΩ 10 MΩ CMC 120 kΩ 20 MΩ CMC 240 kΩ 30 MΩ CMC 360 kΩ 45 MΩ CMC 0,53 MΩ 50 MΩ CMC 0,63 MΩ 90 MΩ CMC 1,1 MΩ 220 MΩ CMC 3,8 MΩ 450 MΩ CMC 8,4 MΩ 900 MΩ CMC 11 MΩ Izolacni odpor / meridla izolacniho odporu, multifunkcni testery Kalibrace – elektricke veliciny Prime mereni etalonovych odporu 0,5 MΩ CMC 6 kΩ 1 MΩ CMC 12 kΩ 2 MΩ CMC 24 kΩ 3 MΩ CMC 36 kΩ 5 MΩ CMC 59 kΩ 9 MΩ CMC 110 kΩ 10 MΩ CMC 120 kΩ 20 MΩ CMC 240 kΩ 30 MΩ CMC 360 kΩ 45 MΩ CMC 0,53 MΩ 50 MΩ CMC 0,63 MΩ 90 MΩ CMC 1,1 MΩ 220 MΩ CMC 3,8 MΩ 450 MΩ CMC 8,4 MΩ 900 MΩ CMC 11 MΩ KA-06","search_en":"Insulation resistance / insulation resistance meters, multifunction testers Calibration – electrical quantities Direct measurement of resistance standards 0,5 MΩ CMC 6 kΩ 1 MΩ CMC 12 kΩ 2 MΩ CMC 24 kΩ 3 MΩ CMC 36 kΩ 5 MΩ CMC 59 kΩ 9 MΩ CMC 110 kΩ 10 MΩ CMC 120 kΩ 20 MΩ CMC 240 kΩ 30 MΩ CMC 360 kΩ 45 MΩ CMC 0,53 MΩ 50 MΩ CMC 0,63 MΩ 90 MΩ CMC 1,1 MΩ 220 MΩ CMC 3,8 MΩ 450 MΩ CMC 8,4 MΩ 900 MΩ CMC 11 MΩ KA-06","search_zh":"绝缘电阻 / 绝缘电阻测量仪、多功能测试仪 校准 – 电学量 直接测量标准电阻 0,5 MΩ CMC 6 kΩ 1 MΩ CMC 12 kΩ 2 MΩ CMC 24 kΩ 3 MΩ CMC 36 kΩ 5 MΩ CMC 59 kΩ 9 MΩ CMC 110 kΩ 10 MΩ CMC 120 kΩ 20 MΩ CMC 240 kΩ 30 MΩ CMC 360 kΩ 45 MΩ CMC 0,53 MΩ 50 MΩ CMC 0,63 MΩ 90 MΩ CMC 1,1 MΩ 220 MΩ CMC 3,8 MΩ 450 MΩ CMC 8,4 MΩ 900 MΩ CMC 11 MΩ KA-06","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"36a4811b3b43c93da02671c7","lab_id":"6ade8b57ff0682476170814c","country":"CZ","accr_number":"2417","accr_body":"ČIA","row_label":"8","test_object":"Rezystancja przy prądzie stałym / testery wielofunkcyjne","test_object_en":"DC resistance / multifunction testers","test_object_zh":"直流电阻 / 多功能测试仪","test_object_cs":"Stejnosměrný odpor / multifunkční testery","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"1 Ω","cmc":"55 mΩ"},{"name":"","range":"5 Ω","cmc":"75 mΩ"},{"name":"","range":"10 Ω","cmc":"150 mΩ"},{"name":"","range":"50 Ω","cmc":"0,75 Ω"},{"name":"","range":"100 Ω","cmc":"1,5 Ω"},{"name":"","range":"450 Ω","cmc":"6,8 Ω"},{"name":"","range":"900 Ω","cmc":"13,5 Ω"}],"parameters_en":[{"name":"","range":"1 Ω","cmc":"55 mΩ"},{"name":"","range":"5 Ω","cmc":"75 mΩ"},{"name":"","range":"10 Ω","cmc":"150 mΩ"},{"name":"","range":"50 Ω","cmc":"0,75 Ω"},{"name":"","range":"100 Ω","cmc":"1,5 Ω"},{"name":"","range":"450 Ω","cmc":"6,8 Ω"},{"name":"","range":"900 Ω","cmc":"13,5 Ω"}],"parameters_zh":[{"name":"","range":"1 Ω","cmc":"55 mΩ"},{"name":"","range":"5 Ω","cmc":"75 mΩ"},{"name":"","range":"10 Ω","cmc":"150 mΩ"},{"name":"","range":"50 Ω","cmc":"0,75 Ω"},{"name":"","range":"100 Ω","cmc":"1,5 Ω"},{"name":"","range":"450 Ω","cmc":"6,8 Ω"},{"name":"","range":"900 Ω","cmc":"13,5 Ω"}],"parameters_cs":[{"name":"","range":"1 Ω","cmc":"55 mΩ"},{"name":"","range":"5 Ω","cmc":"75 mΩ"},{"name":"","range":"10 Ω","cmc":"150 mΩ"},{"name":"","range":"50 Ω","cmc":"0,75 Ω"},{"name":"","range":"100 Ω","cmc":"1,5 Ω"},{"name":"","range":"450 Ω","cmc":"6,8 Ω"},{"name":"","range":"900 Ω","cmc":"13,5 Ω"}],"technique":"Pomiar bezpośredni rezystorów wzorcowych","technique_en":"Direct measurement of resistance standards","technique_zh":"直接测量标准电阻","technique_cs":"Přímé měření etalonových odporů","techniques":["Pomiar bezpośredni rezystorów wzorcowych"],"techniques_en":["Direct measurement of resistance standards"],"techniques_zh":["直接测量标准电阻"],"techniques_cs":["Přímé měření etalonových odporů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n1 Ω CMC 55 mΩ\n5 Ω CMC 75 mΩ\n10 Ω CMC 150 mΩ\n50 Ω CMC 0,75 Ω\n100 Ω CMC 1,5 Ω\n450 Ω CMC 6,8 Ω\n900 Ω CMC 13,5 Ω\nPomiar bezpośredni rezystorów wzorcowych","reference":"KA-06","norm_bases":["KA-06"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / testery wielofunkcyjne Wzorcowanie – wielkości elektryczne Pomiar bezpośredni rezystorów wzorcowych 1 Ω CMC 55 mΩ 5 Ω CMC 75 mΩ 10 Ω CMC 150 mΩ 50 Ω CMC 0,75 Ω 100 Ω CMC 1,5 Ω 450 Ω CMC 6,8 Ω 900 Ω CMC 13,5 Ω Stejnosměrný odpor / multifunkční testery Kalibrace – elektrické veličiny Přímé měření etalonových odporů 1 Ω CMC 55 mΩ 5 Ω CMC 75 mΩ 10 Ω CMC 150 mΩ 50 Ω CMC 0,75 Ω 100 Ω CMC 1,5 Ω 450 Ω CMC 6,8 Ω 900 Ω CMC 13,5 Ω KA-06 Rezystancja przy pradzie stalym / testery wielofunkcyjne Wzorcowanie – wielkosci elektryczne Pomiar bezposredni rezystorow wzorcowych 1 Ω CMC 55 mΩ 5 Ω CMC 75 mΩ 10 Ω CMC 150 mΩ 50 Ω CMC 0,75 Ω 100 Ω CMC 1,5 Ω 450 Ω CMC 6,8 Ω 900 Ω CMC 13,5 Ω Stejnosmerny odpor / multifunkcni testery Kalibrace – elektricke veliciny Prime mereni etalonovych odporu 1 Ω CMC 55 mΩ 5 Ω CMC 75 mΩ 10 Ω CMC 150 mΩ 50 Ω CMC 0,75 Ω 100 Ω CMC 1,5 Ω 450 Ω CMC 6,8 Ω 900 Ω CMC 13,5 Ω KA-06","search_en":"DC resistance / multifunction testers Calibration – electrical quantities Direct measurement of resistance standards 1 Ω CMC 55 mΩ 5 Ω CMC 75 mΩ 10 Ω CMC 150 mΩ 50 Ω CMC 0,75 Ω 100 Ω CMC 1,5 Ω 450 Ω CMC 6,8 Ω 900 Ω CMC 13,5 Ω KA-06","search_zh":"直流电阻 / 多功能测试仪 校准 – 电学量 直接测量标准电阻 1 Ω CMC 55 mΩ 5 Ω CMC 75 mΩ 10 Ω CMC 150 mΩ 50 Ω CMC 0,75 Ω 100 Ω CMC 1,5 Ω 450 Ω CMC 6,8 Ω 900 Ω CMC 13,5 Ω KA-06","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8d3749f2c4e03e10407a0ef2","lab_id":"6ade8b57ff0682476170814c","country":"CZ","accr_number":"2417","accr_body":"ČIA","row_label":"9","test_object":"Rezystancja przy prądzie stałym / testery wielofunkcyjne","test_object_en":"DC resistance / multifunction testers","test_object_zh":"直流电阻 / 多功能测试仪","test_object_cs":"Stejnosměrný odpor / multifunkční testery","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"1 mΩ","cmc":"5,8 µΩ"},{"name":"","range":"10 mΩ","cmc":"58 µΩ"},{"name":"","range":"20 mΩ","cmc":"9,3 µΩ"},{"name":"","range":"50 mΩ","cmc":"22 µΩ"},{"name":"","range":"200 mΩ","cmc":"84 µΩ"},{"name":"","range":"500 mΩ","cmc":"0,21 mΩ"},{"name":"","range":"2 Ω","cmc":"0,77 mΩ"},{"name":"","range":"5 Ω","cmc":"1,9 mΩ"},{"name":"","range":"20 Ω","cmc":"7,7 mΩ"},{"name":"","range":"50 Ω","cmc":"19 mΩ"},{"name":"","range":"200 Ω","cmc":"78 mΩ"},{"name":"","range":"500 Ω","cmc":"0,19 Ω"},{"name":"","range":"2 kΩ","cmc":"0,79 Ω"},{"name":"","range":"5 kΩ","cmc":"1,9 Ω"},{"name":"","range":"20 kΩ","cmc":"7,9 Ω"},{"name":"","range":"50 kΩ","cmc":"19 Ω"},{"name":"","range":"200 kΩ","cmc":"80 Ω"},{"name":"","range":"500 kΩ","cmc":"0,19 kΩ"},{"name":"","range":"2 MΩ","cmc":"0,79 kΩ"},{"name":"","range":"5 MΩ","cmc":"2,5 kΩ"}],"parameters_en":[{"name":"","range":"1 mΩ","cmc":"5,8 µΩ"},{"name":"","range":"10 mΩ","cmc":"58 µΩ"},{"name":"","range":"20 mΩ","cmc":"9,3 µΩ"},{"name":"","range":"50 mΩ","cmc":"22 µΩ"},{"name":"","range":"200 mΩ","cmc":"84 µΩ"},{"name":"","range":"500 mΩ","cmc":"0,21 mΩ"},{"name":"","range":"2 Ω","cmc":"0,77 mΩ"},{"name":"","range":"5 Ω","cmc":"1,9 mΩ"},{"name":"","range":"20 Ω","cmc":"7,7 mΩ"},{"name":"","range":"50 Ω","cmc":"19 mΩ"},{"name":"","range":"200 Ω","cmc":"78 mΩ"},{"name":"","range":"500 Ω","cmc":"0,19 Ω"},{"name":"","range":"2 kΩ","cmc":"0,79 Ω"},{"name":"","range":"5 kΩ","cmc":"1,9 Ω"},{"name":"","range":"20 kΩ","cmc":"7,9 Ω"},{"name":"","range":"50 kΩ","cmc":"19 Ω"},{"name":"","range":"200 kΩ","cmc":"80 Ω"},{"name":"","range":"500 kΩ","cmc":"0,19 kΩ"},{"name":"","range":"2 MΩ","cmc":"0,79 kΩ"},{"name":"","range":"5 MΩ","cmc":"2,5 kΩ"}],"parameters_zh":[{"name":"","range":"1 mΩ","cmc":"5,8 µΩ"},{"name":"","range":"10 mΩ","cmc":"58 µΩ"},{"name":"","range":"20 mΩ","cmc":"9,3 µΩ"},{"name":"","range":"50 mΩ","cmc":"22 µΩ"},{"name":"","range":"200 mΩ","cmc":"84 µΩ"},{"name":"","range":"500 mΩ","cmc":"0,21 mΩ"},{"name":"","range":"2 Ω","cmc":"0,77 mΩ"},{"name":"","range":"5 Ω","cmc":"1,9 mΩ"},{"name":"","range":"20 Ω","cmc":"7,7 mΩ"},{"name":"","range":"50 Ω","cmc":"19 mΩ"},{"name":"","range":"200 Ω","cmc":"78 mΩ"},{"name":"","range":"500 Ω","cmc":"0,19 Ω"},{"name":"","range":"2 kΩ","cmc":"0,79 Ω"},{"name":"","range":"5 kΩ","cmc":"1,9 Ω"},{"name":"","range":"20 kΩ","cmc":"7,9 Ω"},{"name":"","range":"50 kΩ","cmc":"19 Ω"},{"name":"","range":"200 kΩ","cmc":"80 Ω"},{"name":"","range":"500 kΩ","cmc":"0,19 kΩ"},{"name":"","range":"2 MΩ","cmc":"0,79 kΩ"},{"name":"","range":"5 MΩ","cmc":"2,5 kΩ"}],"parameters_cs":[{"name":"","range":"1 mΩ","cmc":"5,8 µΩ"},{"name":"","range":"10 mΩ","cmc":"58 µΩ"},{"name":"","range":"20 mΩ","cmc":"9,3 µΩ"},{"name":"","range":"50 mΩ","cmc":"22 µΩ"},{"name":"","range":"200 mΩ","cmc":"84 µΩ"},{"name":"","range":"500 mΩ","cmc":"0,21 mΩ"},{"name":"","range":"2 Ω","cmc":"0,77 mΩ"},{"name":"","range":"5 Ω","cmc":"1,9 mΩ"},{"name":"","range":"20 Ω","cmc":"7,7 mΩ"},{"name":"","range":"50 Ω","cmc":"19 mΩ"},{"name":"","range":"200 Ω","cmc":"78 mΩ"},{"name":"","range":"500 Ω","cmc":"0,19 Ω"},{"name":"","range":"2 kΩ","cmc":"0,79 Ω"},{"name":"","range":"5 kΩ","cmc":"1,9 Ω"},{"name":"","range":"20 kΩ","cmc":"7,9 Ω"},{"name":"","range":"50 kΩ","cmc":"19 Ω"},{"name":"","range":"200 kΩ","cmc":"80 Ω"},{"name":"","range":"500 kΩ","cmc":"0,19 kΩ"},{"name":"","range":"2 MΩ","cmc":"0,79 kΩ"},{"name":"","range":"5 MΩ","cmc":"2,5 kΩ"}],"technique":"Pomiar bezpośredni rezystorów wzorcowych","technique_en":"Direct measurement of resistance standards","technique_zh":"直接测量标准电阻","technique_cs":"Přímé měření etalonových odporů","techniques":["Pomiar bezpośredni rezystorów wzorcowych"],"techniques_en":["Direct measurement of resistance standards"],"techniques_zh":["直接测量标准电阻"],"techniques_cs":["Přímé měření etalonových odporů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n1 mΩ CMC 5,8 µΩ\n10 mΩ CMC 58 µΩ\n20 mΩ CMC 9,3 µΩ\n50 mΩ CMC 22 µΩ\n200 mΩ CMC 84 µΩ\n500 mΩ CMC 0,21 mΩ\n2 Ω CMC 0,77 mΩ\n5 Ω CMC 1,9 mΩ\n20 Ω CMC 7,7 mΩ\n50 Ω CMC 19 mΩ\n200 Ω CMC 78 mΩ\n500 Ω CMC 0,19 Ω\n2 kΩ CMC 0,79 Ω\n5 kΩ CMC 1,9 Ω\n20 kΩ CMC 7,9 Ω\n50 kΩ CMC 19 Ω\n200 kΩ CMC 80 Ω\n500 kΩ CMC 0,19 kΩ\n2 MΩ CMC 0,79 kΩ\n5 MΩ CMC 2,5 kΩ\nPomiar bezpośredni rezystorów wzorcowych","reference":"KA-05","norm_bases":["KA-05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / testery wielofunkcyjne Wzorcowanie – wielkości elektryczne Pomiar bezpośredni rezystorów wzorcowych 1 mΩ CMC 5,8 µΩ 10 mΩ CMC 58 µΩ 20 mΩ CMC 9,3 µΩ 50 mΩ CMC 22 µΩ 200 mΩ CMC 84 µΩ 500 mΩ CMC 0,21 mΩ 2 Ω CMC 0,77 mΩ 5 Ω CMC 1,9 mΩ 20 Ω CMC 7,7 mΩ 50 Ω CMC 19 mΩ 200 Ω CMC 78 mΩ 500 Ω CMC 0,19 Ω 2 kΩ CMC 0,79 Ω 5 kΩ CMC 1,9 Ω 20 kΩ CMC 7,9 Ω 50 kΩ CMC 19 Ω 200 kΩ CMC 80 Ω 500 kΩ CMC 0,19 kΩ 2 MΩ CMC 0,79 kΩ 5 MΩ CMC 2,5 kΩ Stejnosměrný odpor / multifunkční testery Kalibrace – elektrické veličiny Přímé měření etalonových odporů 1 mΩ CMC 5,8 µΩ 10 mΩ CMC 58 µΩ 20 mΩ CMC 9,3 µΩ 50 mΩ CMC 22 µΩ 200 mΩ CMC 84 µΩ 500 mΩ CMC 0,21 mΩ 2 Ω CMC 0,77 mΩ 5 Ω CMC 1,9 mΩ 20 Ω CMC 7,7 mΩ 50 Ω CMC 19 mΩ 200 Ω CMC 78 mΩ 500 Ω CMC 0,19 Ω 2 kΩ CMC 0,79 Ω 5 kΩ CMC 1,9 Ω 20 kΩ CMC 7,9 Ω 50 kΩ CMC 19 Ω 200 kΩ CMC 80 Ω 500 kΩ CMC 0,19 kΩ 2 MΩ CMC 0,79 kΩ 5 MΩ CMC 2,5 kΩ KA-05 Rezystancja przy pradzie stalym / testery wielofunkcyjne Wzorcowanie – wielkosci elektryczne Pomiar bezposredni rezystorow wzorcowych 1 mΩ CMC 5,8 µΩ 10 mΩ CMC 58 µΩ 20 mΩ CMC 9,3 µΩ 50 mΩ CMC 22 µΩ 200 mΩ CMC 84 µΩ 500 mΩ CMC 0,21 mΩ 2 Ω CMC 0,77 mΩ 5 Ω CMC 1,9 mΩ 20 Ω CMC 7,7 mΩ 50 Ω CMC 19 mΩ 200 Ω CMC 78 mΩ 500 Ω CMC 0,19 Ω 2 kΩ CMC 0,79 Ω 5 kΩ CMC 1,9 Ω 20 kΩ CMC 7,9 Ω 50 kΩ CMC 19 Ω 200 kΩ CMC 80 Ω 500 kΩ CMC 0,19 kΩ 2 MΩ CMC 0,79 kΩ 5 MΩ CMC 2,5 kΩ Stejnosmerny odpor / multifunkcni testery Kalibrace – elektricke veliciny Prime mereni etalonovych odporu 1 mΩ CMC 5,8 µΩ 10 mΩ CMC 58 µΩ 20 mΩ CMC 9,3 µΩ 50 mΩ CMC 22 µΩ 200 mΩ CMC 84 µΩ 500 mΩ CMC 0,21 mΩ 2 Ω CMC 0,77 mΩ 5 Ω CMC 1,9 mΩ 20 Ω CMC 7,7 mΩ 50 Ω CMC 19 mΩ 200 Ω CMC 78 mΩ 500 Ω CMC 0,19 Ω 2 kΩ CMC 0,79 Ω 5 kΩ CMC 1,9 Ω 20 kΩ CMC 7,9 Ω 50 kΩ CMC 19 Ω 200 kΩ CMC 80 Ω 500 kΩ CMC 0,19 kΩ 2 MΩ CMC 0,79 kΩ 5 MΩ CMC 2,5 kΩ KA-05","search_en":"DC resistance / multifunction testers Calibration – electrical quantities Direct measurement of resistance standards 1 mΩ CMC 5,8 µΩ 10 mΩ CMC 58 µΩ 20 mΩ CMC 9,3 µΩ 50 mΩ CMC 22 µΩ 200 mΩ CMC 84 µΩ 500 mΩ CMC 0,21 mΩ 2 Ω CMC 0,77 mΩ 5 Ω CMC 1,9 mΩ 20 Ω CMC 7,7 mΩ 50 Ω CMC 19 mΩ 200 Ω CMC 78 mΩ 500 Ω CMC 0,19 Ω 2 kΩ CMC 0,79 Ω 5 kΩ CMC 1,9 Ω 20 kΩ CMC 7,9 Ω 50 kΩ CMC 19 Ω 200 kΩ CMC 80 Ω 500 kΩ CMC 0,19 kΩ 2 MΩ CMC 0,79 kΩ 5 MΩ CMC 2,5 kΩ KA-05","search_zh":"直流电阻 / 多功能测试仪 校准 – 电学量 直接测量标准电阻 1 mΩ CMC 5,8 µΩ 10 mΩ CMC 58 µΩ 20 mΩ CMC 9,3 µΩ 50 mΩ CMC 22 µΩ 200 mΩ CMC 84 µΩ 500 mΩ CMC 0,21 mΩ 2 Ω CMC 0,77 mΩ 5 Ω CMC 1,9 mΩ 20 Ω CMC 7,7 mΩ 50 Ω CMC 19 mΩ 200 Ω CMC 78 mΩ 500 Ω CMC 0,19 Ω 2 kΩ CMC 0,79 Ω 5 kΩ CMC 1,9 Ω 20 kΩ CMC 7,9 Ω 50 kΩ CMC 19 Ω 200 kΩ CMC 80 Ω 500 kΩ CMC 0,19 kΩ 2 MΩ CMC 0,79 kΩ 5 MΩ CMC 2,5 kΩ KA-05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}