{"lab":{"_id":"6ade8b56ff0682476170814a","accr_number":"2415","country":"CZ","accr_body":"ČIA","address":"Hroznová 63/2, Pisárky, 603 00 Brno","categories":["metrology"],"city":"Brno","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[16.5717229,49.1938372]},"map_coord":[49.1938372,16.5717229],"map_geo":"cai-mapa","methods_count":3,"name":"Ústřední kontrolní a zkušební ústav zemědělský","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinach: temperatura i masa, w zakresie określonym w załączniku do świadectwa.","search_text":"ústřední kontrolní a zkušební ústav zemědělský hroznová 63/2, pisárky, 603 00 brno 2415","source_page_url":"https://www.cai.cz/?subjekt=2415-ustredni-kontrolni-a-zkusebni-ustav-zemedelsky","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"29-11-2029","website":"www.ukzuz.gov.cz","certificate_date":"10.03.2026","certificate_no":"110/2026","certificate_replaces":"643/2024 z 29.11.2024","en_official":false,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinach: temperatura i masa, w zakresie określonym w załączniku do świadectwa.","en":"Calibration in the field of temperature and mass, as specified in the appendix to this certificate.","zh":"温度和质量领域的校准，范围见本证书附件。","cs":"Kalibrace v oboru teplota a hmotnost, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące","lab_division_cs":"Kalibrační laboratoř","lab_division_en":"Calibration Laboratory","lab_division_zh":"校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"50ad1c38133cb5bd869b094a9273b9692333eae5f52ec15ffd4806a1ca784ca2","source_pdf_url":"https://www.cai.cz/OA/pdf/110_2026_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"967059fad11260c6560c29c3","lab_id":"6ade8b56ff0682476170814a","country":"CZ","accr_number":"2415","accr_body":"ČIA","row_label":"1","test_object":"Wagi nieautomatyczne","test_object_en":"Scales with non-automatic operation","test_object_zh":"非自动衡器","test_object_cs":"Váhy s neautomatickou činností","methodology":"Wzorcowanie – masa","methodology_en":"Calibration – mass","methodology_zh":"校准 – 质量","methodology_cs":"Kalibrace – hmotnost","parameters":[{"name":"","range":"od 0,1 g do 1 g","cmc":"0,03 mg"},{"name":"","range":"od 1 g do 2 g","cmc":"0,04 mg"},{"name":"","range":"od 2 g do 5 g","cmc":"0,05 mg"},{"name":"","range":"od 5 g do 10 g","cmc":"0,06 mg"},{"name":"","range":"od 10 g do 20 g","cmc":"0,07 mg"},{"name":"","range":"od 20 g do 50 g","cmc":"0,10 mg"},{"name":"","range":"od 50 g do 100 g","cmc":"0,12 mg"},{"name":"","range":"od 100 g do 200 g","cmc":"0,20 mg"},{"name":"","range":"od 200 g do 500 g","cmc":"0,36 mg"}],"parameters_en":[{"name":"","range":"0,1 g to 1 g","cmc":"0,03 mg"},{"name":"","range":"1 g to 2 g","cmc":"0,04 mg"},{"name":"","range":"2 g to 5 g","cmc":"0,05 mg"},{"name":"","range":"5 g to 10 g","cmc":"0,06 mg"},{"name":"","range":"10 g to 20 g","cmc":"0,07 mg"},{"name":"","range":"20 g to 50 g","cmc":"0,10 mg"},{"name":"","range":"50 g to 100 g","cmc":"0,12 mg"},{"name":"","range":"100 g to 200 g","cmc":"0,20 mg"},{"name":"","range":"200 g to 500 g","cmc":"0,36 mg"}],"parameters_zh":[{"name":"","range":"0,1 g 至 1 g","cmc":"0,03 mg"},{"name":"","range":"1 g 至 2 g","cmc":"0,04 mg"},{"name":"","range":"2 g 至 5 g","cmc":"0,05 mg"},{"name":"","range":"5 g 至 10 g","cmc":"0,06 mg"},{"name":"","range":"10 g 至 20 g","cmc":"0,07 mg"},{"name":"","range":"20 g 至 50 g","cmc":"0,10 mg"},{"name":"","range":"50 g 至 100 g","cmc":"0,12 mg"},{"name":"","range":"100 g 至 200 g","cmc":"0,20 mg"},{"name":"","range":"200 g 至 500 g","cmc":"0,36 mg"}],"parameters_cs":[{"name":"","range":"0,1 g až 1 g","cmc":"0,03 mg"},{"name":"","range":"1 g až 2 g","cmc":"0,04 mg"},{"name":"","range":"2 g až 5 g","cmc":"0,05 mg"},{"name":"","range":"5 g až 10 g","cmc":"0,06 mg"},{"name":"","range":"10 g až 20 g","cmc":"0,07 mg"},{"name":"","range":"20 g až 50 g","cmc":"0,10 mg"},{"name":"","range":"50 g až 100 g","cmc":"0,12 mg"},{"name":"","range":"100 g až 200 g","cmc":"0,20 mg"},{"name":"","range":"200 g až 500 g","cmc":"0,36 mg"}],"technique":"Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy E2","technique_en":"Loading with a standard weight (according to OIML R111-1:2004) of class E2","technique_zh":"用 E2 级标准砝码加载（依据 OIML R111-1:2004）","technique_cs":"Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy E2","techniques":["Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy E2"],"techniques_en":["Loading with a standard weight (according to OIML R111-1:2004) of class E2"],"techniques_zh":["用 E2 级标准砝码加载（依据 OIML R111-1:2004）"],"techniques_cs":["Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy E2"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – masa\nZakres:\nod 0,1 g do 1 g CMC 0,03 mg\nod 1 g do 2 g CMC 0,04 mg\nod 2 g do 5 g CMC 0,05 mg\nod 5 g do 10 g CMC 0,06 mg\nod 10 g do 20 g CMC 0,07 mg\nod 20 g do 50 g CMC 0,10 mg\nod 50 g do 100 g CMC 0,12 mg\nod 100 g do 200 g CMC 0,20 mg\nod 200 g do 500 g CMC 0,36 mg\nObciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy E2","reference":"SPP KL II","norm_bases":["SPP KL II"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: masa","regulatory_area_en":"CMC for the field of measured quantity: Mass","regulatory_area_zh":"被测量领域的CMC：质量","regulatory_area_cs":"CMC pro obor měřené veličiny: Hmotnost","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wagi nieautomatyczne Wzorcowanie – masa Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy E2 od 0,1 g do 1 g CMC 0,03 mg od 1 g do 2 g CMC 0,04 mg od 2 g do 5 g CMC 0,05 mg od 5 g do 10 g CMC 0,06 mg od 10 g do 20 g CMC 0,07 mg od 20 g do 50 g CMC 0,10 mg od 50 g do 100 g CMC 0,12 mg od 100 g do 200 g CMC 0,20 mg od 200 g do 500 g CMC 0,36 mg Váhy s neautomatickou činností Kalibrace – hmotnost Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy E2 0,1 g až 1 g CMC 0,03 mg 1 g až 2 g CMC 0,04 mg 2 g až 5 g CMC 0,05 mg 5 g až 10 g CMC 0,06 mg 10 g až 20 g CMC 0,07 mg 20 g až 50 g CMC 0,10 mg 50 g až 100 g CMC 0,12 mg 100 g až 200 g CMC 0,20 mg 200 g až 500 g CMC 0,36 mg SPP KL II Wagi nieautomatyczne Wzorcowanie – masa Obciazenie odwaznikiem wzorcowym (wg OIML R111-1:2004) klasy E2 od 0,1 g do 1 g CMC 0,03 mg od 1 g do 2 g CMC 0,04 mg od 2 g do 5 g CMC 0,05 mg od 5 g do 10 g CMC 0,06 mg od 10 g do 20 g CMC 0,07 mg od 20 g do 50 g CMC 0,10 mg od 50 g do 100 g CMC 0,12 mg od 100 g do 200 g CMC 0,20 mg od 200 g do 500 g CMC 0,36 mg Vahy s neautomatickou cinnosti Kalibrace – hmotnost Zatizeni etalonovym zavazim (dle OIML R111-1:2004) tridy E2 0,1 g az 1 g CMC 0,03 mg 1 g az 2 g CMC 0,04 mg 2 g az 5 g CMC 0,05 mg 5 g az 10 g CMC 0,06 mg 10 g az 20 g CMC 0,07 mg 20 g az 50 g CMC 0,10 mg 50 g az 100 g CMC 0,12 mg 100 g az 200 g CMC 0,20 mg 200 g az 500 g CMC 0,36 mg SPP KL II","search_en":"Scales with non-automatic operation Calibration – mass Loading with a standard weight (according to OIML R111-1:2004) of class E2 0,1 g to 1 g CMC 0,03 mg 1 g to 2 g CMC 0,04 mg 2 g to 5 g CMC 0,05 mg 5 g to 10 g CMC 0,06 mg 10 g to 20 g CMC 0,07 mg 20 g to 50 g CMC 0,10 mg 50 g to 100 g CMC 0,12 mg 100 g to 200 g CMC 0,20 mg 200 g to 500 g CMC 0,36 mg SPP KL II","search_zh":"非自动衡器 校准 – 质量 用 E2 级标准砝码加载（依据 OIML R111-1:2004） 0,1 g 至 1 g CMC 0,03 mg 1 g 至 2 g CMC 0,04 mg 2 g 至 5 g CMC 0,05 mg 5 g 至 10 g CMC 0,06 mg 10 g 至 20 g CMC 0,07 mg 20 g 至 50 g CMC 0,10 mg 50 g 至 100 g CMC 0,12 mg 100 g 至 200 g CMC 0,20 mg 200 g 至 500 g CMC 0,36 mg SPP KL II","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bd290170d51809a2e11ba7e5","lab_id":"6ade8b56ff0682476170814a","country":"CZ","accr_number":"2415","accr_body":"ČIA","row_label":"1","test_object":"Wagi nieautomatyczne","test_object_en":"Scales with non-automatic operation","test_object_zh":"非自动衡器","test_object_cs":"Váhy s neautomatickou činností","methodology":"Wzorcowanie – masa","methodology_en":"Calibration – mass","methodology_zh":"校准 – 质量","methodology_cs":"Kalibrace – hmotnost","parameters":[{"name":"","range":"od 500 g do 1 kg","cmc":"8,7 mg"},{"name":"","range":"od 1 kg do 2 kg","cmc":"10 mg"},{"name":"","range":"od 2 kg do 5 kg","cmc":"15 mg"}],"parameters_en":[{"name":"","range":"500 g to 1 kg","cmc":"8,7 mg"},{"name":"","range":"1 kg to 2 kg","cmc":"10 mg"},{"name":"","range":"2 kg to 5 kg","cmc":"15 mg"}],"parameters_zh":[{"name":"","range":"500 g 至 1 kg","cmc":"8,7 mg"},{"name":"","range":"1 kg 至 2 kg","cmc":"10 mg"},{"name":"","range":"2 kg 至 5 kg","cmc":"15 mg"}],"parameters_cs":[{"name":"","range":"500 g až 1 kg","cmc":"8,7 mg"},{"name":"","range":"1 kg až 2 kg","cmc":"10 mg"},{"name":"","range":"2 kg až 5 kg","cmc":"15 mg"}],"technique":"Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy F1","technique_en":"Loading with a standard weight (according to OIML R111-1:2004) of class F1","technique_zh":"用 F1 级标准砝码加载（依据 OIML R111-1:2004）","technique_cs":"Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy F1","techniques":["Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy F1"],"techniques_en":["Loading with a standard weight (according to OIML R111-1:2004) of class F1"],"techniques_zh":["用 F1 级标准砝码加载（依据 OIML R111-1:2004）"],"techniques_cs":["Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy F1"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – masa\nZakres:\nod 500 g do 1 kg CMC 8,7 mg\nod 1 kg do 2 kg CMC 10 mg\nod 2 kg do 5 kg CMC 15 mg\nObciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy F1","reference":"SPP KL II","norm_bases":["SPP KL II"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: masa","regulatory_area_en":"CMC for the field of measured quantity: Mass","regulatory_area_zh":"被测量领域的CMC：质量","regulatory_area_cs":"CMC pro obor měřené veličiny: Hmotnost","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wagi nieautomatyczne Wzorcowanie – masa Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy F1 od 500 g do 1 kg CMC 8,7 mg od 1 kg do 2 kg CMC 10 mg od 2 kg do 5 kg CMC 15 mg Váhy s neautomatickou činností Kalibrace – hmotnost Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy F1 500 g až 1 kg CMC 8,7 mg 1 kg až 2 kg CMC 10 mg 2 kg až 5 kg CMC 15 mg SPP KL II Wagi nieautomatyczne Wzorcowanie – masa Obciazenie odwaznikiem wzorcowym (wg OIML R111-1:2004) klasy F1 od 500 g do 1 kg CMC 8,7 mg od 1 kg do 2 kg CMC 10 mg od 2 kg do 5 kg CMC 15 mg Vahy s neautomatickou cinnosti Kalibrace – hmotnost Zatizeni etalonovym zavazim (dle OIML R111-1:2004) tridy F1 500 g az 1 kg CMC 8,7 mg 1 kg az 2 kg CMC 10 mg 2 kg az 5 kg CMC 15 mg SPP KL II","search_en":"Scales with non-automatic operation Calibration – mass Loading with a standard weight (according to OIML R111-1:2004) of class F1 500 g to 1 kg CMC 8,7 mg 1 kg to 2 kg CMC 10 mg 2 kg to 5 kg CMC 15 mg SPP KL II","search_zh":"非自动衡器 校准 – 质量 用 F1 级标准砝码加载（依据 OIML R111-1:2004） 500 g 至 1 kg CMC 8,7 mg 1 kg 至 2 kg CMC 10 mg 2 kg 至 5 kg CMC 15 mg SPP KL II","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0f7e138e69d885b069bbacb7","lab_id":"6ade8b56ff0682476170814a","country":"CZ","accr_number":"2415","accr_body":"ČIA","row_label":"1","test_object":"Termometry elektroniczne jako części urządzeń cieplnych","test_object_en":"Electronic thermometers as parts of thermal equipment","test_object_zh":"作为热工设备组成部分的电子温度计","test_object_cs":"Elektronické teploměry jako součásti tepelných zařízení","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -80 °C do 0 °C","cmc":"0,6 °C"},{"name":"","range":"od 0 °C do 100 °C","cmc":"0,5 °C"},{"name":"","range":"od 100 °C do 300 °C","cmc":"0,5 °C"},{"name":"","range":"od 300 °C do 500 °C","cmc":"1,6 °C"},{"name":"","range":"od 500 °C do 800 °C","cmc":"1,9 °C"}],"parameters_en":[{"name":"","range":"-80 °C to 0 °C","cmc":"0,6 °C"},{"name":"","range":"0 °C to 100 °C","cmc":"0,5 °C"},{"name":"","range":"100 °C to 300 °C","cmc":"0,5 °C"},{"name":"","range":"300 °C to 500 °C","cmc":"1,6 °C"},{"name":"","range":"500 °C to 800 °C","cmc":"1,9 °C"}],"parameters_zh":[{"name":"","range":"-80 °C 至 0 °C","cmc":"0,6 °C"},{"name":"","range":"0 °C 至 100 °C","cmc":"0,5 °C"},{"name":"","range":"100 °C 至 300 °C","cmc":"0,5 °C"},{"name":"","range":"300 °C 至 500 °C","cmc":"1,6 °C"},{"name":"","range":"500 °C 至 800 °C","cmc":"1,9 °C"}],"parameters_cs":[{"name":"","range":"-80 °C až 0 °C","cmc":"0,6 °C"},{"name":"","range":"0 °C až 100 °C","cmc":"0,5 °C"},{"name":"","range":"100 °C až 300 °C","cmc":"0,5 °C"},{"name":"","range":"300 °C až 500 °C","cmc":"1,6 °C"},{"name":"","range":"500 °C až 800 °C","cmc":"1,9 °C"}],"technique":"Bezpośrednie porównanie z termometrem wzorcowym","technique_en":"Direct comparison with a standard thermometer","technique_zh":"与标准温度计直接比较","technique_cs":"Přímé porovnání s etalonovým teploměrem","techniques":["Bezpośrednie porównanie z termometrem wzorcowym"],"techniques_en":["Direct comparison with a standard thermometer"],"techniques_zh":["与标准温度计直接比较"],"techniques_cs":["Přímé porovnání s etalonovým teploměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -80 °C do 0 °C CMC 0,6 °C\nod 0 °C do 100 °C CMC 0,5 °C\nod 100 °C do 300 °C CMC 0,5 °C\nod 300 °C do 500 °C CMC 1,6 °C\nod 500 °C do 800 °C CMC 1,9 °C\nBezpośrednie porównanie z termometrem wzorcowym","reference":"SPP KL I","norm_bases":["SPP KL I"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry elektroniczne jako części urządzeń cieplnych Wzorcowanie – temperatura Bezpośrednie porównanie z termometrem wzorcowym od -80 °C do 0 °C CMC 0,6 °C od 0 °C do 100 °C CMC 0,5 °C od 100 °C do 300 °C CMC 0,5 °C od 300 °C do 500 °C CMC 1,6 °C od 500 °C do 800 °C CMC 1,9 °C Elektronické teploměry jako součásti tepelných zařízení Kalibrace – teplota Přímé porovnání s etalonovým teploměrem -80 °C až 0 °C CMC 0,6 °C 0 °C až 100 °C CMC 0,5 °C 100 °C až 300 °C CMC 0,5 °C 300 °C až 500 °C CMC 1,6 °C 500 °C až 800 °C CMC 1,9 °C SPP KL I Termometry elektroniczne jako czesci urzadzen cieplnych Wzorcowanie – temperatura Bezposrednie porownanie z termometrem wzorcowym od -80 °C do 0 °C CMC 0,6 °C od 0 °C do 100 °C CMC 0,5 °C od 100 °C do 300 °C CMC 0,5 °C od 300 °C do 500 °C CMC 1,6 °C od 500 °C do 800 °C CMC 1,9 °C Elektronicke teplomery jako soucasti tepelnych zarizeni Kalibrace – teplota Prime porovnani s etalonovym teplomerem -80 °C az 0 °C CMC 0,6 °C 0 °C az 100 °C CMC 0,5 °C 100 °C az 300 °C CMC 0,5 °C 300 °C az 500 °C CMC 1,6 °C 500 °C az 800 °C CMC 1,9 °C SPP KL I","search_en":"Electronic thermometers as parts of thermal equipment Calibration – temperature Direct comparison with a standard thermometer -80 °C to 0 °C CMC 0,6 °C 0 °C to 100 °C CMC 0,5 °C 100 °C to 300 °C CMC 0,5 °C 300 °C to 500 °C CMC 1,6 °C 500 °C to 800 °C CMC 1,9 °C SPP KL I","search_zh":"作为热工设备组成部分的电子温度计 校准 – 温度 与标准温度计直接比较 -80 °C 至 0 °C CMC 0,6 °C 0 °C 至 100 °C CMC 0,5 °C 100 °C 至 300 °C CMC 0,5 °C 300 °C 至 500 °C CMC 1,6 °C 500 °C 至 800 °C CMC 1,9 °C SPP KL I","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}