{"lab":{"_id":"6ade8b55ff06824761708149","accr_number":"2414","country":"CZ","accr_body":"ČIA","address":"T.G.Masaryka 2104, 272 01 Kladno","categories":["metrology"],"city":"Kladno","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[14.0959615,50.1456502]},"map_coord":[50.1456502,14.0959615],"map_geo":"cai-mapa","methods_count":7,"name":"METROTEST s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinach: długość, siła i twardość, w zakresie określonym w załączniku do świadectwa.","search_text":"metrotest s.r.o. t.g.masaryka 2104, 272 01 kladno 2414","source_page_url":"https://www.cai.cz/?subjekt=2414-metrotest-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"05-06-2029","website":"www.metrotest.cz","certificate_date":"30.09.2025","certificate_no":"493/2025","certificate_replaces":"244/2024 z 29.05.2024","en_official":false,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinach: długość, siła i twardość, w zakresie określonym w załączniku do świadectwa.","en":"Calibration in the field of length, force and hardness, as specified in the appendix to this certificate.","zh":"长度、力和硬度领域的校准，范围见本证书附件。","cs":"Kalibrace v oboru délka, síla a tvrdost, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące METROTEST","lab_division_cs":"Kalibrační laboratoř METROTEST","lab_division_en":"Calibration Laboratory METROTEST","lab_division_zh":"METROTEST 校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"cee1b08f066c098ee56cbf0f01d6e5e8ed4f2037aa1d6835140157572cda48ef","source_pdf_url":"https://www.cai.cz/OA/pdf/493_2025_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"764e0b617f97f6323f2fc7d6","lab_id":"6ade8b55ff06824761708149","country":"CZ","accr_number":"2414","accr_body":"ČIA","row_label":"1","test_object":"Wzorcowanie ramion pomiarowych","test_object_en":"Calibration of measuring arms","test_object_zh":"测量臂的校准","test_object_cs":"Kalibrace měřicích ramen","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 m do 4,5 m","cmc":"(1,5L + 2) µm"}],"parameters_en":[{"name":"","range":"0 m to 4,5 m","cmc":"(1,5L + 2) µm"}],"parameters_zh":[{"name":"","range":"0 m 至 4,5 m","cmc":"(1,5L + 2) µm"}],"parameters_cs":[{"name":"","range":"0 m až 4,5 m","cmc":"(1,5L + 2) µm"}],"technique":"Wzorcem stożkowym i kulą wzorcową","technique_en":"With a cone standard and a calibration ball","technique_zh":"用锥形标准器和校准球","technique_cs":"Kónusovým etalonem a kalibrační koulí","techniques":["Wzorcem stożkowym i kulą wzorcową"],"techniques_en":["With a cone standard and a calibration ball"],"techniques_zh":["用锥形标准器和校准球"],"techniques_cs":["Kónusovým etalonem a kalibrační koulí"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 m do 4,5 m CMC (1,5L + 2) µm\nWzorcem stożkowym i kulą wzorcową","reference":"KP01 (ASME B89.4.22)","norm_bases":["KP01","ASME B89.4.22"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wzorcowanie ramion pomiarowych Wzorcowanie – długość Wzorcem stożkowym i kulą wzorcową od 0 m do 4,5 m CMC (1,5L + 2) µm Kalibrace měřicích ramen Kalibrace – délka Kónusovým etalonem a kalibrační koulí 0 m až 4,5 m CMC (1,5L + 2) µm KP01 (ASME B89.4.22) Wzorcowanie ramion pomiarowych Wzorcowanie – dlugosc Wzorcem stozkowym i kula wzorcowa od 0 m do 4,5 m CMC (1,5L + 2) µm Kalibrace mericich ramen Kalibrace – delka Konusovym etalonem a kalibracni kouli 0 m az 4,5 m CMC (1,5L + 2) µm KP01 (ASME B89.4.22)","search_en":"Calibration of measuring arms Calibration – length With a cone standard and a calibration ball 0 m to 4,5 m CMC (1,5L + 2) µm KP01 (ASME B89.4.22)","search_zh":"测量臂的校准 校准 – 长度 用锥形标准器和校准球 0 m 至 4,5 m CMC (1,5L + 2) µm KP01 (ASME B89.4.22)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f1b61b8ea676e7b65072aece","lab_id":"6ade8b55ff06824761708149","country":"CZ","accr_number":"2414","accr_body":"ČIA","row_label":"2","test_object":"Wzorcowanie współrzędnościowych maszyn pomiarowych","test_object_en":"Calibration of coordinate measuring machines","test_object_zh":"坐标测量机的校准","test_object_cs":"Kalibraci souřadnicových měřících strojů","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 m do 3 m","cmc":"(1L + 0,25) µm"}],"parameters_en":[{"name":"","range":"0 m to 3 m","cmc":"(1L + 0,25) µm"}],"parameters_zh":[{"name":"","range":"0 m 至 3 m","cmc":"(1L + 0,25) µm"}],"parameters_cs":[{"name":"","range":"0 m až 3 m","cmc":"(1L + 0,25) µm"}],"technique":"Płytkami wzorcowymi i kulą wzorcową","technique_en":"With gauge blocks and a calibration ball","technique_zh":"用量块和校准球","technique_cs":"Koncovými měrkami a kalibrační koulí","techniques":["Płytkami wzorcowymi i kulą wzorcową"],"techniques_en":["With gauge blocks and a calibration ball"],"techniques_zh":["用量块和校准球"],"techniques_cs":["Koncovými měrkami a kalibrační koulí"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 m do 3 m CMC (1L + 0,25) µm\nPłytkami wzorcowymi i kulą wzorcową","reference":"KP06 (ČSN EN ISO 10360-2)","norm_bases":["KP06","ČSN EN ISO 10360-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wzorcowanie współrzędnościowych maszyn pomiarowych Wzorcowanie – długość Płytkami wzorcowymi i kulą wzorcową od 0 m do 3 m CMC (1L + 0,25) µm Kalibraci souřadnicových měřících strojů Kalibrace – délka Koncovými měrkami a kalibrační koulí 0 m až 3 m CMC (1L + 0,25) µm KP06 (ČSN EN ISO 10360-2) Wzorcowanie wspolrzednosciowych maszyn pomiarowych Wzorcowanie – dlugosc Plytkami wzorcowymi i kula wzorcowa od 0 m do 3 m CMC (1L + 0,25) µm Kalibraci souradnicovych mericich stroju Kalibrace – delka Koncovymi merkami a kalibracni kouli 0 m az 3 m CMC (1L + 0,25) µm KP06 (CSN EN ISO 10360-2)","search_en":"Calibration of coordinate measuring machines Calibration – length With gauge blocks and a calibration ball 0 m to 3 m CMC (1L + 0,25) µm KP06 (ČSN EN ISO 10360-2)","search_zh":"坐标测量机的校准 校准 – 长度 用量块和校准球 0 m 至 3 m CMC (1L + 0,25) µm KP06 (ČSN EN ISO 10360-2)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"85caf26259878914175e5227","lab_id":"6ade8b55ff06824761708149","country":"CZ","accr_number":"2414","accr_body":"ČIA","row_label":"1","test_object":"Maszyny wytrzymałościowe do prób rozciągania","test_object_en":"Tensile testing machines","test_object_zh":"拉伸试验机","test_object_cs":"Zkušební trhací stroje","methodology":"Wzorcowanie – siła, badania mechaniczne","methodology_en":"Calibration – force, mechanical tests","methodology_zh":"校准 – 力、机械试验","methodology_cs":"Kalibrace – síla, mechanické zkoušky","parameters":[{"name":"rozciąganie","range":"od 0,04 N do 50 kN","cmc":"0,6 %"}],"parameters_en":[{"name":"tension","range":"0,04 N to 50 kN","cmc":"0,6 %"}],"parameters_zh":[{"name":"拉伸","range":"0,04 N 至 50 kN","cmc":"0,6 %"}],"parameters_cs":[{"name":"tah","range":"0,04 N až 50 kN","cmc":"0,6 %"}],"technique":"Porównanie z siłomierzem wzorcowym","technique_en":"Comparison with a reference force-measuring instrument","technique_zh":"与标准测力仪比较","technique_cs":"Porovnání s etalonovým siloměrem","techniques":["Porównanie z siłomierzem wzorcowym"],"techniques_en":["Comparison with a reference force-measuring instrument"],"techniques_zh":["与标准测力仪比较"],"techniques_cs":["Porovnání s etalonovým siloměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – siła, badania mechaniczne\nrozciąganie od 0,04 N do 50 kN CMC 0,6 %\nPorównanie z siłomierzem wzorcowym","reference":"KP02 (ČSN EN ISO 7501-2; ČSN EN ISO 376; ČSN EN ISO 7500-2; ASTM E4)","norm_bases":["KP02","ČSN EN ISO 7501-2","ČSN EN ISO 376","ČSN EN ISO 7500-2","ASTM E4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: siła, badania mechaniczne","regulatory_area_en":"CMC for the field of measured quantity: Force, mechanical tests","regulatory_area_zh":"被测量领域的CMC：力、机械试验","regulatory_area_cs":"CMC pro obor měřené veličiny: Síla, mechanické zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Maszyny wytrzymałościowe do prób rozciągania Wzorcowanie – siła, badania mechaniczne Porównanie z siłomierzem wzorcowym rozciąganie od 0,04 N do 50 kN CMC 0,6 % Zkušební trhací stroje Kalibrace – síla, mechanické zkoušky Porovnání s etalonovým siloměrem tah 0,04 N až 50 kN CMC 0,6 % KP02 (ČSN EN ISO 7501-2; ČSN EN ISO 376; ČSN EN ISO 7500-2; ASTM E4) Maszyny wytrzymalosciowe do prob rozciagania Wzorcowanie – sila, badania mechaniczne Porownanie z silomierzem wzorcowym rozciaganie od 0,04 N do 50 kN CMC 0,6 % Zkusebni trhaci stroje Kalibrace – sila, mechanicke zkousky Porovnani s etalonovym silomerem tah 0,04 N az 50 kN CMC 0,6 % KP02 (CSN EN ISO 7501-2; CSN EN ISO 376; CSN EN ISO 7500-2; ASTM E4)","search_en":"Tensile testing machines Calibration – force, mechanical tests Comparison with a reference force-measuring instrument tension 0,04 N to 50 kN CMC 0,6 % KP02 (ČSN EN ISO 7501-2; ČSN EN ISO 376; ČSN EN ISO 7500-2; ASTM E4)","search_zh":"拉伸试验机 校准 – 力、机械试验 与标准测力仪比较 拉伸 0,04 N 至 50 kN CMC 0,6 % KP02 (ČSN EN ISO 7501-2; ČSN EN ISO 376; ČSN EN ISO 7500-2; ASTM E4)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b93b071d77081ab4cb1ff65f","lab_id":"6ade8b55ff06824761708149","country":"CZ","accr_number":"2414","accr_body":"ČIA","row_label":"2","test_object":"Prasy probiercze","test_object_en":"Testing presses","test_object_zh":"试验压力机","test_object_cs":"Zkušební lisy","methodology":"Wzorcowanie – siła, badania mechaniczne","methodology_en":"Calibration – force, mechanical tests","methodology_zh":"校准 – 力、机械试验","methodology_cs":"Kalibrace – síla, mechanické zkoušky","parameters":[{"name":"ściskanie","range":"od 0,04 N do 50 kN","cmc":"0,6 %"}],"parameters_en":[{"name":"compression","range":"0,04 N to 50 kN","cmc":"0,6 %"}],"parameters_zh":[{"name":"压缩","range":"0,04 N 至 50 kN","cmc":"0,6 %"}],"parameters_cs":[{"name":"tlak","range":"0,04 N až 50 kN","cmc":"0,6 %"}],"technique":"Porównanie z siłomierzem wzorcowym","technique_en":"Comparison with a reference force-measuring instrument","technique_zh":"与标准测力仪比较","technique_cs":"Porovnání s etalonovým siloměrem","techniques":["Porównanie z siłomierzem wzorcowym"],"techniques_en":["Comparison with a reference force-measuring instrument"],"techniques_zh":["与标准测力仪比较"],"techniques_cs":["Porovnání s etalonovým siloměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – siła, badania mechaniczne\nściskanie od 0,04 N do 50 kN CMC 0,6 %\nPorównanie z siłomierzem wzorcowym","reference":"KP03 (ČSN EN ISO 7501-2; ČSN EN ISO 376; ČSN EN ISO 7500-2; ASTM E4)","norm_bases":["KP03","ČSN EN ISO 7501-2","ČSN EN ISO 376","ČSN EN ISO 7500-2","ASTM E4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: siła, badania mechaniczne","regulatory_area_en":"CMC for the field of measured quantity: Force, mechanical tests","regulatory_area_zh":"被测量领域的CMC：力、机械试验","regulatory_area_cs":"CMC pro obor měřené veličiny: Síla, mechanické zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prasy probiercze Wzorcowanie – siła, badania mechaniczne Porównanie z siłomierzem wzorcowym ściskanie od 0,04 N do 50 kN CMC 0,6 % Zkušební lisy Kalibrace – síla, mechanické zkoušky Porovnání s etalonovým siloměrem tlak 0,04 N až 50 kN CMC 0,6 % KP03 (ČSN EN ISO 7501-2; ČSN EN ISO 376; ČSN EN ISO 7500-2; ASTM E4) Prasy probiercze Wzorcowanie – sila, badania mechaniczne Porownanie z silomierzem wzorcowym sciskanie od 0,04 N do 50 kN CMC 0,6 % Zkusebni lisy Kalibrace – sila, mechanicke zkousky Porovnani s etalonovym silomerem tlak 0,04 N az 50 kN CMC 0,6 % KP03 (CSN EN ISO 7501-2; CSN EN ISO 376; CSN EN ISO 7500-2; ASTM E4)","search_en":"Testing presses Calibration – force, mechanical tests Comparison with a reference force-measuring instrument compression 0,04 N to 50 kN CMC 0,6 % KP03 (ČSN EN ISO 7501-2; ČSN EN ISO 376; ČSN EN ISO 7500-2; ASTM E4)","search_zh":"试验压力机 校准 – 力、机械试验 与标准测力仪比较 压缩 0,04 N 至 50 kN CMC 0,6 % KP03 (ČSN EN ISO 7501-2; ČSN EN ISO 376; ČSN EN ISO 7500-2; ASTM E4)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2920b64b3d121d54b42c9d49","lab_id":"6ade8b55ff06824761708149","country":"CZ","accr_number":"2414","accr_body":"ČIA","row_label":"3","test_object":"Twardość – Twardościomierze","test_object_en":"Hardness – Hardness testers","test_object_zh":"硬度 – 硬度计","test_object_cs":"Tvrdost – Tvrdoměry","methodology":"Wzorcowanie – siła, badania mechaniczne","methodology_en":"Calibration – force, mechanical tests","methodology_zh":"校准 – 力、机械试验","methodology_cs":"Kalibrace – síla, mechanické zkoušky","parameters":[{"name":"Rockwell C","range":"od 10 HRC do 80 HRC","cmc":"0,5 HRC"}],"parameters_en":[{"name":"Rockwell C","range":"10 HRC to 80 HRC","cmc":"0,5 HRC"}],"parameters_zh":[{"name":"洛氏 C","range":"10 HRC 至 80 HRC","cmc":"0,5 HRC"}],"parameters_cs":[{"name":"Rockwell C","range":"10 HRC až 80 HRC","cmc":"0,5 HRC"}],"technique":"ČSN EN ISO 6508-2","technique_en":"ČSN EN ISO 6508-2","technique_zh":"ČSN EN ISO 6508-2","technique_cs":"ČSN EN ISO 6508-2","techniques":["ČSN EN ISO 6508-2"],"techniques_en":["ČSN EN ISO 6508-2"],"techniques_zh":["ČSN EN ISO 6508-2"],"techniques_cs":["ČSN EN ISO 6508-2"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – siła, badania mechaniczne\nRockwell C od 10 HRC do 80 HRC CMC 0,5 HRC\nČSN EN ISO 6508-2","reference":"KP04","norm_bases":["KP04"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: siła, badania mechaniczne","regulatory_area_en":"CMC for the field of measured quantity: Force, mechanical tests","regulatory_area_zh":"被测量领域的CMC：力、机械试验","regulatory_area_cs":"CMC pro obor měřené veličiny: Síla, mechanické zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Twardość – Twardościomierze Wzorcowanie – siła, badania mechaniczne ČSN EN ISO 6508-2 Rockwell C od 10 HRC do 80 HRC CMC 0,5 HRC Tvrdost – Tvrdoměry Kalibrace – síla, mechanické zkoušky ČSN EN ISO 6508-2 Rockwell C 10 HRC až 80 HRC CMC 0,5 HRC KP04 Twardosc – Twardosciomierze Wzorcowanie – sila, badania mechaniczne CSN EN ISO 6508-2 Rockwell C od 10 HRC do 80 HRC CMC 0,5 HRC Tvrdost – Tvrdomery Kalibrace – sila, mechanicke zkousky CSN EN ISO 6508-2 Rockwell C 10 HRC az 80 HRC CMC 0,5 HRC KP04","search_en":"Hardness – Hardness testers Calibration – force, mechanical tests ČSN EN ISO 6508-2 Rockwell C 10 HRC to 80 HRC CMC 0,5 HRC KP04","search_zh":"硬度 – 硬度计 校准 – 力、机械试验 ČSN EN ISO 6508-2 洛氏 C 10 HRC 至 80 HRC CMC 0,5 HRC KP04","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c1186cfa7153a39898860467","lab_id":"6ade8b55ff06824761708149","country":"CZ","accr_number":"2414","accr_body":"ČIA","row_label":"3","test_object":"Twardość – Twardościomierze","test_object_en":"Hardness – Hardness testers","test_object_zh":"硬度 – 硬度计","test_object_cs":"Tvrdost – Tvrdoměry","methodology":"Wzorcowanie – siła, badania mechaniczne","methodology_en":"Calibration – force, mechanical tests","methodology_zh":"校准 – 力、机械试验","methodology_cs":"Kalibrace – síla, mechanické zkoušky","parameters":[{"name":"Vickers","range":"od 20 HV do 3000 HV","cmc":"0,5 %"}],"parameters_en":[{"name":"Vickers","range":"20 HV to 3000 HV","cmc":"0,5 %"}],"parameters_zh":[{"name":"维氏","range":"20 HV 至 3000 HV","cmc":"0,5 %"}],"parameters_cs":[{"name":"Vickers","range":"20 HV až 3000 HV","cmc":"0,5 %"}],"technique":"ČSN EN ISO 6507-2","technique_en":"ČSN EN ISO 6507-2","technique_zh":"ČSN EN ISO 6507-2","technique_cs":"ČSN EN ISO 6507-2","techniques":["ČSN EN ISO 6507-2"],"techniques_en":["ČSN EN ISO 6507-2"],"techniques_zh":["ČSN EN ISO 6507-2"],"techniques_cs":["ČSN EN ISO 6507-2"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – siła, badania mechaniczne\nVickers od 20 HV do 3000 HV CMC 0,5 %\nČSN EN ISO 6507-2","reference":"KP04","norm_bases":["KP04"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: siła, badania mechaniczne","regulatory_area_en":"CMC for the field of measured quantity: Force, mechanical tests","regulatory_area_zh":"被测量领域的CMC：力、机械试验","regulatory_area_cs":"CMC pro obor měřené veličiny: Síla, mechanické zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Twardość – Twardościomierze Wzorcowanie – siła, badania mechaniczne ČSN EN ISO 6507-2 Vickers od 20 HV do 3000 HV CMC 0,5 % Tvrdost – Tvrdoměry Kalibrace – síla, mechanické zkoušky ČSN EN ISO 6507-2 Vickers 20 HV až 3000 HV CMC 0,5 % KP04 Twardosc – Twardosciomierze Wzorcowanie – sila, badania mechaniczne CSN EN ISO 6507-2 Vickers od 20 HV do 3000 HV CMC 0,5 % Tvrdost – Tvrdomery Kalibrace – sila, mechanicke zkousky CSN EN ISO 6507-2 Vickers 20 HV az 3000 HV CMC 0,5 % KP04","search_en":"Hardness – Hardness testers Calibration – force, mechanical tests ČSN EN ISO 6507-2 Vickers 20 HV to 3000 HV CMC 0,5 % KP04","search_zh":"硬度 – 硬度计 校准 – 力、机械试验 ČSN EN ISO 6507-2 维氏 20 HV 至 3000 HV CMC 0,5 % KP04","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fdf450f56e3a8182bb6ee00c","lab_id":"6ade8b55ff06824761708149","country":"CZ","accr_number":"2414","accr_body":"ČIA","row_label":"3","test_object":"Twardość – Twardościomierze","test_object_en":"Hardness – Hardness testers","test_object_zh":"硬度 – 硬度计","test_object_cs":"Tvrdost – Tvrdoměry","methodology":"Wzorcowanie – siła, badania mechaniczne","methodology_en":"Calibration – force, mechanical tests","methodology_zh":"校准 – 力、机械试验","methodology_cs":"Kalibrace – síla, mechanické zkoušky","parameters":[{"name":"Brinell","range":"od 20 HBW do 650 HBW","cmc":"0,5 %"}],"parameters_en":[{"name":"Brinell","range":"20 HBW to 650 HBW","cmc":"0,5 %"}],"parameters_zh":[{"name":"布氏","range":"20 HBW 至 650 HBW","cmc":"0,5 %"}],"parameters_cs":[{"name":"Brinell","range":"20 HBW až 650 HBW","cmc":"0,5 %"}],"technique":"ČSN EN ISO 6506-2","technique_en":"ČSN EN ISO 6506-2","technique_zh":"ČSN EN ISO 6506-2","technique_cs":"ČSN EN ISO 6506-2","techniques":["ČSN EN ISO 6506-2"],"techniques_en":["ČSN EN ISO 6506-2"],"techniques_zh":["ČSN EN ISO 6506-2"],"techniques_cs":["ČSN EN ISO 6506-2"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – siła, badania mechaniczne\nBrinell od 20 HBW do 650 HBW CMC 0,5 %\nČSN EN ISO 6506-2","reference":"KP04","norm_bases":["KP04"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: siła, badania mechaniczne","regulatory_area_en":"CMC for the field of measured quantity: Force, mechanical tests","regulatory_area_zh":"被测量领域的CMC：力、机械试验","regulatory_area_cs":"CMC pro obor měřené veličiny: Síla, mechanické zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Twardość – Twardościomierze Wzorcowanie – siła, badania mechaniczne ČSN EN ISO 6506-2 Brinell od 20 HBW do 650 HBW CMC 0,5 % Tvrdost – Tvrdoměry Kalibrace – síla, mechanické zkoušky ČSN EN ISO 6506-2 Brinell 20 HBW až 650 HBW CMC 0,5 % KP04 Twardosc – Twardosciomierze Wzorcowanie – sila, badania mechaniczne CSN EN ISO 6506-2 Brinell od 20 HBW do 650 HBW CMC 0,5 % Tvrdost – Tvrdomery Kalibrace – sila, mechanicke zkousky CSN EN ISO 6506-2 Brinell 20 HBW az 650 HBW CMC 0,5 % KP04","search_en":"Hardness – Hardness testers Calibration – force, mechanical tests ČSN EN ISO 6506-2 Brinell 20 HBW to 650 HBW CMC 0,5 % KP04","search_zh":"硬度 – 硬度计 校准 – 力、机械试验 ČSN EN ISO 6506-2 布氏 20 HBW 至 650 HBW CMC 0,5 % KP04","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}