{"lab":{"_id":"6ade8b54ff06824761708146","accr_number":"2410","country":"CZ","accr_body":"ČIA","address":"Jihlavská 340/20, 625 00 Brno","categories":["metrology"],"city":"Brno","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[16.5765726,49.1743893]},"map_coord":[49.1743893,16.5765726],"map_geo":"cai-mapa","methods_count":1,"name":"Fakultní nemocnice Brno","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie pipet tłokowych, w zakresie określonym w załączniku do świadectwa.","search_text":"fakultní nemocnice brno jihlavská 340/20, 625 00 brno 2410","source_page_url":"https://www.cai.cz/?subjekt=2410-fakultni-nemocnice-brno","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"10-10-2027","website":"www.fnbrno.cz","certificate_date":"19.05.2025","certificate_no":"236/2025","certificate_replaces":"474/2022 z 10.10.2022","en_official":false,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie pipet tłokowych, w zakresie określonym w załączniku do świadectwa.","en":"Calibration of piston pipettes, as specified in the appendix to this certificate.","zh":"活塞式移液器的校准，范围见本证书附件。","cs":"Kalibrace pístových pipet vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące Działu Techniki Medycznej","lab_division_cs":"Kalibrační laboratoř Oddělení zdravotnické techniky","lab_division_en":"Calibration Laboratory of the Medical Technology Department","lab_division_zh":"医疗技术部校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"952140ac38abb25642c44a3d3dde21355b2e8490554e5f1b1ad660bf9b0e0375","source_pdf_url":"https://www.cai.cz/OA/pdf/236_2025_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"4b9aa5d04e51516b6b01d7af","lab_id":"6ade8b54ff06824761708146","country":"CZ","accr_number":"2410","accr_body":"ČIA","row_label":"1","test_object":"Pipety tłokowe","test_object_en":"Piston pipettes","test_object_zh":"活塞式移液器","test_object_cs":"Pístové pipety","methodology":"Wzorcowanie – objętość","methodology_en":"Calibration – volume","methodology_zh":"校准 – 体积","methodology_cs":"Kalibrace – objem","parameters":[{"name":"","range":"od 1 µl do 5 µl","cmc":"0,27 %"},{"name":"","range":"od 5 µl do 20 µl","cmc":"0,13 %"},{"name":"","range":"od 20 µl do 10 ml","cmc":"0,12 %"}],"parameters_en":[{"name":"","range":"1 µl to 5 µl","cmc":"0,27 %"},{"name":"","range":"5 µl to 20 µl","cmc":"0,13 %"},{"name":"","range":"20 µl to 10 ml","cmc":"0,12 %"}],"parameters_zh":[{"name":"","range":"1 µl 至 5 µl","cmc":"0,27 %"},{"name":"","range":"5 µl 至 20 µl","cmc":"0,13 %"},{"name":"","range":"20 µl 至 10 ml","cmc":"0,12 %"}],"parameters_cs":[{"name":"","range":"1 µl až 5 µl","cmc":"0,27 %"},{"name":"","range":"5 µl až 20 µl","cmc":"0,13 %"},{"name":"","range":"20 µl až 10 ml","cmc":"0,12 %"}],"technique":"Metoda grawimetryczna","technique_en":"Gravimetric method","technique_zh":"重量法","technique_cs":"Gravimetrická metoda","techniques":["Metoda grawimetryczna"],"techniques_en":["Gravimetric method"],"techniques_zh":["重量法"],"techniques_cs":["Gravimetrická metoda"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – objętość\nZakres:\nod 1 µl do 5 µl CMC 0,27 %\nod 5 µl do 20 µl CMC 0,13 %\nod 20 µl do 10 ml CMC 0,12 %\nMetoda grawimetryczna","reference":"R/OZT/2221 (ČSN EN ISO 8655-6; EURAMET cg-19 verze 3.0, 09/2018)","norm_bases":["R/OZT/2221","ČSN EN ISO 8655-6","EURAMET cg-19 verze 3.0, 09/2018"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: objętość","regulatory_area_en":"CMC for the field of measured quantity: Volume","regulatory_area_zh":"被测量领域的CMC：体积","regulatory_area_cs":"CMC pro obor měřené veličiny: Objem","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pipety tłokowe Wzorcowanie – objętość Metoda grawimetryczna od 1 µl do 5 µl CMC 0,27 % od 5 µl do 20 µl CMC 0,13 % od 20 µl do 10 ml CMC 0,12 % Pístové pipety Kalibrace – objem Gravimetrická metoda 1 µl až 5 µl CMC 0,27 % 5 µl až 20 µl CMC 0,13 % 20 µl až 10 ml CMC 0,12 % R/OZT/2221 (ČSN EN ISO 8655-6; EURAMET cg-19 verze 3.0, 09/2018) Pipety tlokowe Wzorcowanie – objetosc Metoda grawimetryczna od 1 µl do 5 µl CMC 0,27 % od 5 µl do 20 µl CMC 0,13 % od 20 µl do 10 ml CMC 0,12 % Pistove pipety Kalibrace – objem Gravimetricka metoda 1 µl az 5 µl CMC 0,27 % 5 µl az 20 µl CMC 0,13 % 20 µl az 10 ml CMC 0,12 % R/OZT/2221 (CSN EN ISO 8655-6; EURAMET cg-19 verze 3.0, 09/2018)","search_en":"Piston pipettes Calibration – volume Gravimetric method 1 µl to 5 µl CMC 0,27 % 5 µl to 20 µl CMC 0,13 % 20 µl to 10 ml CMC 0,12 % R/OZT/2221 (ČSN EN ISO 8655-6; EURAMET cg-19 verze 3.0, 09/2018)","search_zh":"活塞式移液器 校准 – 体积 重量法 1 µl 至 5 µl CMC 0,27 % 5 µl 至 20 µl CMC 0,13 % 20 µl 至 10 ml CMC 0,12 % R/OZT/2221 (ČSN EN ISO 8655-6; EURAMET cg-19 verze 3.0, 09/2018)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}