{"lab":{"_id":"6ade8b53ff06824761708142","accr_number":"2406","country":"CZ","accr_body":"ČIA","address":"Rostoklaty 30, 287 71 Rostoklaty","categories":["metrology"],"city":"Rostoklaty","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[14.7960296,50.0755722]},"map_coord":[50.0755722,14.7960296],"map_geo":"cai-mapa","methods_count":5,"name":"Pro Metrology s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie tłokowych przyrządów do pomiaru objętości oraz przyrządów do pomiaru czasu i temperatury, w zakresie określonym w załączniku do świadectwa.","search_text":"pro metrology s.r.o. rostoklaty 30, 287 71 rostoklaty 2406","source_page_url":"https://www.cai.cz/?subjekt=2406-pro-metrology-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"27-05-2027","website":"www.procalibration.cz","certificate_date":"13.05.2026","certificate_no":"244/2026","certificate_replaces":"577/2023 z 06.11.2023","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie tłokowych przyrządów do pomiaru objętości oraz przyrządów do pomiaru czasu i temperatury, w zakresie określonym w załączniku do świadectwa.","en":"Calibration of piston volume meters and time and temperature meters to the extent as specified in the appendix to this Certificate.","zh":"活塞式容量计量器具以及时间和温度计量器具的校准，范围见本证书附件。","cs":"Kalibrace pístových měřidel objemu a měřidel času a teploty, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"PROCALIBRATION – Laboratorium wzorcujące","lab_division_cs":"PROCALIBRATION – Kalibrační laboratoř","lab_division_en":"PROCALIBRATION – Calibration Laboratory","lab_division_zh":"PROCALIBRATION – 校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[{"pl":"Laboratorium wydaje opinie i interpretacje wyników wzorcowań.","en":"The laboratory provides opinions and interpretations of the calibration results.","zh":"实验室提供校准结果的意见和解释。","cs":"Laboratoř poskytuje stanoviska a interpretace výsledků kalibrací."}],"source_lang":"cs","source_pdf_sha256":"d1a369f631437e3eadc9985f9658eb454a3302151d4970bce06ce81757bbcf78","source_pdf_url":"https://www.cai.cz/OA/pdf/244_2026_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/244_2026_EN.pdf"},"methods":[{"_id":"6ea5258df647b0a3dfeb19e0","lab_id":"6ade8b53ff06824761708142","country":"CZ","accr_number":"2406","accr_body":"ČIA","row_label":"1","test_object":"Tłokowe przyrządy do pomiaru objętości","test_object_en":"Piston volume meters","test_object_zh":"活塞式容量计量器具","test_object_cs":"Pístová objemová měřidla","methodology":"Wzorcowanie – objętość","methodology_en":"Calibration – volume","methodology_zh":"校准 – 体积","methodology_cs":"Kalibrace – objem","parameters":[{"name":"Woda destylowana","range":"od 0,1 µl do 10000 µl","cmc":"0,12 % + 0,03 µl"},{"name":"Woda destylowana","range":"od 10000 µl do 200000 µl","cmc":"0,08 %"}],"parameters_en":[{"name":"Distilled water","range":"0,1 µl to 10000 µl","cmc":"0,12 % + 0,03 µl"},{"name":"Distilled water","range":"10000 µl to 200000 µl","cmc":"0,08 %"}],"parameters_zh":[{"name":"蒸馏水","range":"0,1 µl 至 10000 µl","cmc":"0,12 % + 0,03 µl"},{"name":"蒸馏水","range":"10000 µl 至 200000 µl","cmc":"0,08 %"}],"parameters_cs":[{"name":"Destilovaná voda","range":"0,1 µl až 10000 µl","cmc":"0,12 % + 0,03 µl"},{"name":"Destilovaná voda","range":"10000 µl až 200000 µl","cmc":"0,08 %"}],"technique":"Metoda grawimetryczna","technique_en":"Gravimetric method","technique_zh":"重量法","technique_cs":"Gravimetrická metoda","techniques":["Metoda grawimetryczna"],"techniques_en":["Gravimetric method"],"techniques_zh":["重量法"],"techniques_cs":["Gravimetrická metoda"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – objętość\nZakres:\nWoda destylowana od 0,1 µl do 10000 µl CMC 0,12 % + 0,03 µl\nWoda destylowana od 10000 µl do 200000 µl CMC 0,08 %\nMetoda grawimetryczna","reference":"PROC_30_000 Objem GM (ČSN EN ISO 8655-6; EURAMET Calibration Guide No. 19, Version 4.1 (12/2025))","norm_bases":["PROC_30_000 Objem GM","ČSN EN ISO 8655-6","EURAMET Calibration Guide No. 19, Version 4.1 (12/2025)"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: objętość","regulatory_area_en":"CMC for the field of measured quantity: Volume","regulatory_area_zh":"被测量领域的CMC：体积","regulatory_area_cs":"CMC pro obor měřené veličiny: Objem","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Tłokowe przyrządy do pomiaru objętości Wzorcowanie – objętość Metoda grawimetryczna Woda destylowana od 0,1 µl do 10000 µl CMC 0,12 % + 0,03 µl Woda destylowana od 10000 µl do 200000 µl CMC 0,08 % Pístová objemová měřidla Kalibrace – objem Gravimetrická metoda Destilovaná voda 0,1 µl až 10000 µl CMC 0,12 % + 0,03 µl Destilovaná voda 10000 µl až 200000 µl CMC 0,08 % PROC_30_000 Objem GM (ČSN EN ISO 8655-6; EURAMET Calibration Guide No. 19, Version 4.1 (12/2025)) Tlokowe przyrzady do pomiaru objetosci Wzorcowanie – objetosc Metoda grawimetryczna Woda destylowana od 0,1 µl do 10000 µl CMC 0,12 % + 0,03 µl Woda destylowana od 10000 µl do 200000 µl CMC 0,08 % Pistova objemova meridla Kalibrace – objem Gravimetricka metoda Destilovana voda 0,1 µl az 10000 µl CMC 0,12 % + 0,03 µl Destilovana voda 10000 µl az 200000 µl CMC 0,08 % PROC_30_000 Objem GM (CSN EN ISO 8655-6; EURAMET Calibration Guide No. 19, Version 4.1 (12/2025))","search_en":"Piston volume meters Calibration – volume Gravimetric method Distilled water 0,1 µl to 10000 µl CMC 0,12 % + 0,03 µl Distilled water 10000 µl to 200000 µl CMC 0,08 % PROC_30_000 Objem GM (ČSN EN ISO 8655-6; EURAMET Calibration Guide No. 19, Version 4.1 (12/2025))","search_zh":"活塞式容量计量器具 校准 – 体积 重量法 蒸馏水 0,1 µl 至 10000 µl CMC 0,12 % + 0,03 µl 蒸馏水 10000 µl 至 200000 µl CMC 0,08 % PROC_30_000 Objem GM (ČSN EN ISO 8655-6; EURAMET Calibration Guide No. 19, Version 4.1 (12/2025))","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3c7bd81702f62696b08fddf3","lab_id":"6ade8b53ff06824761708142","country":"CZ","accr_number":"2406","accr_body":"ČIA","row_label":"1","test_object":"Termometry elektroniczne, rejestratory temperatury","test_object_en":"Electronic thermometers, temperature recorders","test_object_zh":"电子温度计、温度记录仪","test_object_cs":"Elektronické teploměry, záznamníky teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -30 °C do 0 °C","cmc":"0,2 °C"},{"name":"","range":"od 0 °C do 30 °C","cmc":"0,15 °C"},{"name":"","range":"od 30 °C do 80 °C","cmc":"0,07 °C"},{"name":"","range":"od 80 °C do 130 °C","cmc":"0,2 °C"},{"name":"","range":"od 130 °C do 150 °C","cmc":"0,3 °C"}],"parameters_en":[{"name":"","range":"-30 °C to 0 °C","cmc":"0,2 °C"},{"name":"","range":"0 °C to 30 °C","cmc":"0,15 °C"},{"name":"","range":"30 °C to 80 °C","cmc":"0,07 °C"},{"name":"","range":"80 °C to 130 °C","cmc":"0,2 °C"},{"name":"","range":"130 °C to 150 °C","cmc":"0,3 °C"}],"parameters_zh":[{"name":"","range":"-30 °C 至 0 °C","cmc":"0,2 °C"},{"name":"","range":"0 °C 至 30 °C","cmc":"0,15 °C"},{"name":"","range":"30 °C 至 80 °C","cmc":"0,07 °C"},{"name":"","range":"80 °C 至 130 °C","cmc":"0,2 °C"},{"name":"","range":"130 °C 至 150 °C","cmc":"0,3 °C"}],"parameters_cs":[{"name":"","range":"-30 °C až 0 °C","cmc":"0,2 °C"},{"name":"","range":"0 °C až 30 °C","cmc":"0,15 °C"},{"name":"","range":"30 °C až 80 °C","cmc":"0,07 °C"},{"name":"","range":"80 °C až 130 °C","cmc":"0,2 °C"},{"name":"","range":"130 °C až 150 °C","cmc":"0,3 °C"}],"technique":"Bezpośrednie porównanie z cyfrowym termometrem wzorcowym","technique_en":"Direct comparison with a reference digital thermometer","technique_zh":"与标准数字温度计直接比较","technique_cs":"Přímé porovnání s etalonovým digitálním teploměrem","techniques":["Bezpośrednie porównanie z cyfrowym termometrem wzorcowym"],"techniques_en":["Direct comparison with a reference digital thermometer"],"techniques_zh":["与标准数字温度计直接比较"],"techniques_cs":["Přímé porovnání s etalonovým digitálním teploměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -30 °C do 0 °C CMC 0,2 °C\nod 0 °C do 30 °C CMC 0,15 °C\nod 30 °C do 80 °C CMC 0,07 °C\nod 80 °C do 130 °C CMC 0,2 °C\nod 130 °C do 150 °C CMC 0,3 °C\nBezpośrednie porównanie z cyfrowym termometrem wzorcowym","reference":"PROC_30_100_Teplota_EL","norm_bases":["PROC_30_100_Teplota_EL"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry elektroniczne, rejestratory temperatury Wzorcowanie – temperatura Bezpośrednie porównanie z cyfrowym termometrem wzorcowym od -30 °C do 0 °C CMC 0,2 °C od 0 °C do 30 °C CMC 0,15 °C od 30 °C do 80 °C CMC 0,07 °C od 80 °C do 130 °C CMC 0,2 °C od 130 °C do 150 °C CMC 0,3 °C Elektronické teploměry, záznamníky teploty Kalibrace – teplota Přímé porovnání s etalonovým digitálním teploměrem -30 °C až 0 °C CMC 0,2 °C 0 °C až 30 °C CMC 0,15 °C 30 °C až 80 °C CMC 0,07 °C 80 °C až 130 °C CMC 0,2 °C 130 °C až 150 °C CMC 0,3 °C PROC_30_100_Teplota_EL Termometry elektroniczne, rejestratory temperatury Wzorcowanie – temperatura Bezposrednie porownanie z cyfrowym termometrem wzorcowym od -30 °C do 0 °C CMC 0,2 °C od 0 °C do 30 °C CMC 0,15 °C od 30 °C do 80 °C CMC 0,07 °C od 80 °C do 130 °C CMC 0,2 °C od 130 °C do 150 °C CMC 0,3 °C Elektronicke teplomery, zaznamniky teploty Kalibrace – teplota Prime porovnani s etalonovym digitalnim teplomerem -30 °C az 0 °C CMC 0,2 °C 0 °C az 30 °C CMC 0,15 °C 30 °C az 80 °C CMC 0,07 °C 80 °C az 130 °C CMC 0,2 °C 130 °C az 150 °C CMC 0,3 °C PROC_30_100_Teplota_EL","search_en":"Electronic thermometers, temperature recorders Calibration – temperature Direct comparison with a reference digital thermometer -30 °C to 0 °C CMC 0,2 °C 0 °C to 30 °C CMC 0,15 °C 30 °C to 80 °C CMC 0,07 °C 80 °C to 130 °C CMC 0,2 °C 130 °C to 150 °C CMC 0,3 °C PROC_30_100_Teplota_EL","search_zh":"电子温度计、温度记录仪 校准 – 温度 与标准数字温度计直接比较 -30 °C 至 0 °C CMC 0,2 °C 0 °C 至 30 °C CMC 0,15 °C 30 °C 至 80 °C CMC 0,07 °C 80 °C 至 130 °C CMC 0,2 °C 130 °C 至 150 °C CMC 0,3 °C PROC_30_100_Teplota_EL","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4eee7179d1ee4086c07e1fc3","lab_id":"6ade8b53ff06824761708142","country":"CZ","accr_number":"2406","accr_body":"ČIA","row_label":"2","test_object":"Termometry szklane","test_object_en":"Glass thermometers","test_object_zh":"玻璃温度计","test_object_cs":"Skleněné teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 30 °C do 80 °C","cmc":"0,07 °C"}],"parameters_en":[{"name":"","range":"30 °C to 80 °C","cmc":"0,07 °C"}],"parameters_zh":[{"name":"","range":"30 °C 至 80 °C","cmc":"0,07 °C"}],"parameters_cs":[{"name":"","range":"30 °C až 80 °C","cmc":"0,07 °C"}],"technique":"Bezpośrednie porównanie z cyfrowym termometrem wzorcowym","technique_en":"Direct comparison with a reference digital thermometer","technique_zh":"与标准数字温度计直接比较","technique_cs":"Přímé porovnání s etalonovým digitálním teploměrem","techniques":["Bezpośrednie porównanie z cyfrowym termometrem wzorcowym"],"techniques_en":["Direct comparison with a reference digital thermometer"],"techniques_zh":["与标准数字温度计直接比较"],"techniques_cs":["Přímé porovnání s etalonovým digitálním teploměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod 30 °C do 80 °C CMC 0,07 °C\nBezpośrednie porównanie z cyfrowym termometrem wzorcowym","reference":"PROC_30_110_Teplota_SKL","norm_bases":["PROC_30_110_Teplota_SKL"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry szklane Wzorcowanie – temperatura Bezpośrednie porównanie z cyfrowym termometrem wzorcowym od 30 °C do 80 °C CMC 0,07 °C Skleněné teploměry Kalibrace – teplota Přímé porovnání s etalonovým digitálním teploměrem 30 °C až 80 °C CMC 0,07 °C PROC_30_110_Teplota_SKL Termometry szklane Wzorcowanie – temperatura Bezposrednie porownanie z cyfrowym termometrem wzorcowym od 30 °C do 80 °C CMC 0,07 °C Sklenene teplomery Kalibrace – teplota Prime porovnani s etalonovym digitalnim teplomerem 30 °C az 80 °C CMC 0,07 °C PROC_30_110_Teplota_SKL","search_en":"Glass thermometers Calibration – temperature Direct comparison with a reference digital thermometer 30 °C to 80 °C CMC 0,07 °C PROC_30_110_Teplota_SKL","search_zh":"玻璃温度计 校准 – 温度 与标准数字温度计直接比较 30 °C 至 80 °C CMC 0,07 °C PROC_30_110_Teplota_SKL","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c265bf84bf889e8dc25059cc","lab_id":"6ade8b53ff06824761708142","country":"CZ","accr_number":"2406","accr_body":"ČIA","row_label":"3","test_object":"Termometry bezkontaktowe na podczerwień","test_object_en":"Infrared non-contact thermometers","test_object_zh":"红外非接触式温度计","test_object_cs":"Infračervené bezdotykové teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 20 °C do 37 °C","cmc":"1,1 °C"},{"name":"","range":"od 37 °C do 50 °C","cmc":"1,3 °C"}],"parameters_en":[{"name":"","range":"20 °C to 37 °C","cmc":"1,1 °C"},{"name":"","range":"37 °C to 50 °C","cmc":"1,3 °C"}],"parameters_zh":[{"name":"","range":"20 °C 至 37 °C","cmc":"1,1 °C"},{"name":"","range":"37 °C 至 50 °C","cmc":"1,3 °C"}],"parameters_cs":[{"name":"","range":"20 °C až 37 °C","cmc":"1,1 °C"},{"name":"","range":"37 °C až 50 °C","cmc":"1,3 °C"}],"technique":"Bezpośrednie porównanie z wzorcowym ciałem czarnym","technique_en":"Direct comparison with a reference black body","technique_zh":"与标准黑体直接比较","technique_cs":"Přímé porovnání s etalonovým černým tělesem","techniques":["Bezpośrednie porównanie z wzorcowym ciałem czarnym"],"techniques_en":["Direct comparison with a reference black body"],"techniques_zh":["与标准黑体直接比较"],"techniques_cs":["Přímé porovnání s etalonovým černým tělesem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 20 °C do 37 °C CMC 1,1 °C\nod 37 °C do 50 °C CMC 1,3 °C\nBezpośrednie porównanie z wzorcowym ciałem czarnym","reference":"PROC_30_300_Teplota_INF","norm_bases":["PROC_30_300_Teplota_INF"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry bezkontaktowe na podczerwień Wzorcowanie – temperatura Bezpośrednie porównanie z wzorcowym ciałem czarnym od 20 °C do 37 °C CMC 1,1 °C od 37 °C do 50 °C CMC 1,3 °C Infračervené bezdotykové teploměry Kalibrace – teplota Přímé porovnání s etalonovým černým tělesem 20 °C až 37 °C CMC 1,1 °C 37 °C až 50 °C CMC 1,3 °C PROC_30_300_Teplota_INF Termometry bezkontaktowe na podczerwien Wzorcowanie – temperatura Bezposrednie porownanie z wzorcowym cialem czarnym od 20 °C do 37 °C CMC 1,1 °C od 37 °C do 50 °C CMC 1,3 °C Infracervene bezdotykove teplomery Kalibrace – teplota Prime porovnani s etalonovym cernym telesem 20 °C az 37 °C CMC 1,1 °C 37 °C az 50 °C CMC 1,3 °C PROC_30_300_Teplota_INF","search_en":"Infrared non-contact thermometers Calibration – temperature Direct comparison with a reference black body 20 °C to 37 °C CMC 1,1 °C 37 °C to 50 °C CMC 1,3 °C PROC_30_300_Teplota_INF","search_zh":"红外非接触式温度计 校准 – 温度 与标准黑体直接比较 20 °C 至 37 °C CMC 1,1 °C 37 °C 至 50 °C CMC 1,3 °C PROC_30_300_Teplota_INF","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d57c7b9eaffec2f5c33d9be4","lab_id":"6ade8b53ff06824761708142","country":"CZ","accr_number":"2406","accr_body":"ČIA","row_label":"1","test_object":"Czas / Stopery cyfrowe i mechaniczne","test_object_en":"Time / Digital and mechanical stopwatch","test_object_zh":"时间 / 数字和机械秒表","test_object_cs":"Čas / Stopky digitální a mechanické","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"Działka elementarna 0,1 s","range":"od 10 s do 86 400 s","cmc":"0,059 s + 7,99·10⁻⁶·ΔT"}],"parameters_en":[{"name":"Scale division 0,1 s","range":"10 s to 86 400 s","cmc":"0,059 s + 7,99·10⁻⁶·ΔT"}],"parameters_zh":[{"name":"分度值 0,1 s","range":"10 s 至 86 400 s","cmc":"0,059 s + 7,99·10⁻⁶·ΔT"}],"parameters_cs":[{"name":"Dílek stupnice 0,1 s","range":"10 s až 86 400 s","cmc":"0,059 s + 7,99·10⁻⁶·ΔT"}],"technique":"Bezpośrednie porównanie ze stoperami wzorcowymi","technique_en":"Direct comparison with a standard stopwatch","technique_zh":"与标准秒表直接比较","technique_cs":"Přímé porovnání s etalonovými stopkami","techniques":["Bezpośrednie porównanie ze stoperami wzorcowymi"],"techniques_en":["Direct comparison with a standard stopwatch"],"techniques_zh":["与标准秒表直接比较"],"techniques_cs":["Přímé porovnání s etalonovými stopkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\nDziałka elementarna 0,1 s od 10 s do 86 400 s CMC 0,059 s + 7,99·10⁻⁶·ΔT\nBezpośrednie porównanie ze stoperami wzorcowymi","reference":"PROC-30-050 Kalibrační postup ČAS (NIST 960-12, KP 6.1.2/02/14)","norm_bases":["PROC-30-050 Kalibrační postup ČAS","NIST 960-12","KP 6.1.2/02/14"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Czas / Stopery cyfrowe i mechaniczne Wzorcowanie – wielkości czasu i częstotliwości Bezpośrednie porównanie ze stoperami wzorcowymi Działka elementarna 0,1 s od 10 s do 86 400 s CMC 0,059 s + 7,99·10⁻⁶·ΔT Čas / Stopky digitální a mechanické Kalibrace – veličiny času a frekvence Přímé porovnání s etalonovými stopkami Dílek stupnice 0,1 s 10 s až 86 400 s CMC 0,059 s + 7,99·10⁻⁶·ΔT PROC-30-050 Kalibrační postup ČAS (NIST 960-12, KP 6.1.2/02/14) Czas / Stopery cyfrowe i mechaniczne Wzorcowanie – wielkosci czasu i czestotliwosci Bezposrednie porownanie ze stoperami wzorcowymi Dzialka elementarna 0,1 s od 10 s do 86 400 s CMC 0,059 s + 7,99·10⁻⁶·ΔT Cas / Stopky digitalni a mechanicke Kalibrace – veliciny casu a frekvence Prime porovnani s etalonovymi stopkami Dilek stupnice 0,1 s 10 s az 86 400 s CMC 0,059 s + 7,99·10⁻⁶·ΔT PROC-30-050 Kalibracni postup CAS (NIST 960-12, KP 6.1.2/02/14)","search_en":"Time / Digital and mechanical stopwatch Calibration – time and frequency quantities Direct comparison with a standard stopwatch Scale division 0,1 s 10 s to 86 400 s CMC 0,059 s + 7,99·10⁻⁶·ΔT PROC-30-050 Kalibrační postup ČAS (NIST 960-12, KP 6.1.2/02/14)","search_zh":"时间 / 数字和机械秒表 校准 – 时间和频率量 与标准秒表直接比较 分度值 0,1 s 10 s 至 86 400 s CMC 0,059 s + 7,99·10⁻⁶·ΔT PROC-30-050 Kalibrační postup ČAS (NIST 960-12, KP 6.1.2/02/14)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}