{"lab":{"_id":"6ade8b52ff06824761708141","accr_number":"2405","country":"CZ","accr_body":"ČIA","address":"UNO TECHNOLOGY PARK Bezděčín, Hala H1a, č.p. 108, 293 01 Mladá Boleslav","categories":["metrology"],"city":"Mladá Boleslav","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[14.9032588,50.3895763]},"map_coord":[50.3895763,14.9032588],"map_geo":"nominatim-street","methods_count":17,"name":"TÜV SÜD Czech s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinach: długość, kąt płaski, ruch mechaniczny, ciśnienie, częstotliwość i czas, w zakresie określonym w załączniku do świadectwa.","search_text":"tüv süd czech s.r.o. uno technology park bezděčín, hala h1a, č.p. 108, 293 01 mladá boleslav 2405","source_page_url":"https://www.cai.cz/?subjekt=2405-tuv-sud-czech-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"05-02-2029","website":"tuvsud.com/cz","certificate_date":"02.07.2025","certificate_no":"332/2025","certificate_replaces":"47/2024 z 05.02.2024","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinach: długość, kąt płaski, ruch mechaniczny, ciśnienie, częstotliwość i czas, w zakresie określonym w załączniku do świadectwa.","en":"Calibrations in the field of length, plane angle, mechanical motion, pressure, frequency and time to the extent as specified in the appendix to this Certificate.","zh":"长度、平面角、机械运动、压力、频率和时间领域的校准，范围见本证书附件。","cs":"Kalibrace v oborech délka, rovinný úhel, mechanický pohyb, tlak, frekvence a čas, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące","lab_division_cs":"Kalibrační laboratoř","lab_division_en":"Calibration Laboratory","lab_division_zh":"校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"L","pl":"mierzona długość w metrach","en":"measured length in metres","zh":"以米为单位的测量长度","cs":"měřená délka v metrech"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"55346b70f1813063575c0129eef4d55fb442d2b6c1e076b7d4b48a2ee64cd30b","source_pdf_url":"https://www.cai.cz/OA/pdf/332_2025_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/332_2025_EN.pdf"},"methods":[{"_id":"0e6b6dde3754b150cb7e172a","lab_id":"6ade8b52ff06824761708141","country":"CZ","accr_number":"2405","accr_body":"ČIA","row_label":"1","test_object":"Czujniki położenia i odległości","test_object_en":"Sensors of distance and position","test_object_zh":"位置和距离传感器","test_object_cs":"Snímače polohy a odstupu","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 300 mm","cmc":"0,04 mm"},{"name":"","range":"od 300 mm do 1500 mm","cmc":"0,30 mm"}],"parameters_en":[{"name":"","range":"0 mm to 300 mm","cmc":"0,04 mm"},{"name":"","range":"300 mm to 1500 mm","cmc":"0,30 mm"}],"parameters_zh":[{"name":"","range":"0 mm 至 300 mm","cmc":"0,04 mm"},{"name":"","range":"300 mm 至 1500 mm","cmc":"0,30 mm"}],"parameters_cs":[{"name":"","range":"0 mm až 300 mm","cmc":"0,04 mm"},{"name":"","range":"300 mm až 1500 mm","cmc":"0,30 mm"}],"technique":"porównanie z wysokościomierzem","technique_en":"comparison with a height gauge","technique_zh":"与高度尺比较","technique_cs":"porovnání s výškoměrem","techniques":["porównanie z wysokościomierzem"],"techniques_en":["comparison with a height gauge"],"techniques_zh":["与高度尺比较"],"techniques_cs":["porovnání s výškoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nod 0 mm do 300 mm CMC 0,04 mm\nod 300 mm do 1500 mm CMC 0,30 mm\nporównanie z wysokościomierzem","reference":"I540 – 068 – 10","norm_bases":["I540 – 068 – 10"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Czujniki położenia i odległości Wzorcowanie – długość porównanie z wysokościomierzem od 0 mm do 300 mm CMC 0,04 mm od 300 mm do 1500 mm CMC 0,30 mm Snímače polohy a odstupu Kalibrace – délka porovnání s výškoměrem 0 mm až 300 mm CMC 0,04 mm 300 mm až 1500 mm CMC 0,30 mm I540 – 068 – 10 Czujniki polozenia i odleglosci Wzorcowanie – dlugosc porownanie z wysokosciomierzem od 0 mm do 300 mm CMC 0,04 mm od 300 mm do 1500 mm CMC 0,30 mm Snimace polohy a odstupu Kalibrace – delka porovnani s vyskomerem 0 mm az 300 mm CMC 0,04 mm 300 mm az 1500 mm CMC 0,30 mm I540 – 068 – 10","search_en":"Sensors of distance and position Calibration – length comparison with a height gauge 0 mm to 300 mm CMC 0,04 mm 300 mm to 1500 mm CMC 0,30 mm I540 – 068 – 10","search_zh":"位置和距离传感器 校准 – 长度 与高度尺比较 0 mm 至 300 mm CMC 0,04 mm 300 mm 至 1500 mm CMC 0,30 mm I540 – 068 – 10","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"89ea2bfe464d24d9e3d8eb26","lab_id":"6ade8b52ff06824761708141","country":"CZ","accr_number":"2405","accr_body":"ČIA","row_label":"2","test_object":"Czujniki ruchu taśmy","test_object_en":"Belt motion sensors","test_object_zh":"带运动传感器","test_object_cs":"Snímače pohybu pásu","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od -400 mm do 400 mm","cmc":"(0,2·L + 0,40) mm"}],"parameters_en":[{"name":"","range":"-400 mm to 400 mm","cmc":"(0,2·L + 0,40) mm"}],"parameters_zh":[{"name":"","range":"-400 mm 至 400 mm","cmc":"(0,2·L + 0,40) mm"}],"parameters_cs":[{"name":"","range":"-400 mm až 400 mm","cmc":"(0,2·L + 0,40) mm"}],"technique":"porównanie z przyrządem wzorcującym","technique_en":"comparison with a calibration jig","technique_zh":"与校准夹具比较","technique_cs":"porovnání s kalibračním přípravkem","techniques":["porównanie z przyrządem wzorcującym"],"techniques_en":["comparison with a calibration jig"],"techniques_zh":["与校准夹具比较"],"techniques_cs":["porovnání s kalibračním přípravkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod -400 mm do 400 mm CMC (0,2·L + 0,40) mm\nporównanie z przyrządem wzorcującym","reference":"I540 – 068 – 10","norm_bases":["I540 – 068 – 10"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Czujniki ruchu taśmy Wzorcowanie – długość porównanie z przyrządem wzorcującym od -400 mm do 400 mm CMC (0,2·L + 0,40) mm Snímače pohybu pásu Kalibrace – délka porovnání s kalibračním přípravkem -400 mm až 400 mm CMC (0,2·L + 0,40) mm I540 – 068 – 10 Czujniki ruchu tasmy Wzorcowanie – dlugosc porownanie z przyrzadem wzorcujacym od -400 mm do 400 mm CMC (0,2·L + 0,40) mm Snimace pohybu pasu Kalibrace – delka porovnani s kalibracnim pripravkem -400 mm az 400 mm CMC (0,2·L + 0,40) mm I540 – 068 – 10","search_en":"Belt motion sensors Calibration – length comparison with a calibration jig -400 mm to 400 mm CMC (0,2·L + 0,40) mm I540 – 068 – 10","search_zh":"带运动传感器 校准 – 长度 与校准夹具比较 -400 mm 至 400 mm CMC (0,2·L + 0,40) mm I540 – 068 – 10","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cf395a0bb208acdfa93106a8","lab_id":"6ade8b52ff06824761708141","country":"CZ","accr_number":"2405","accr_body":"ČIA","row_label":"1","test_object":"Czujniki położenia i inklinometry","test_object_en":"Sensors of position and inclinometers","test_object_zh":"位置传感器和倾角仪","test_object_cs":"Snímače polohy a inklinoměry","methodology":"Wzorcowanie – kąt płaski","methodology_en":"Calibration – plane angle","methodology_zh":"校准 – 平面角","methodology_cs":"Kalibrace – rovinný úhel","parameters":[{"name":"","range":"od 0 ° do 360 °","cmc":"0,02°"}],"parameters_en":[{"name":"","range":"0 ° to 360 °","cmc":"0,02°"}],"parameters_zh":[{"name":"","range":"0 ° 至 360 °","cmc":"0,02°"}],"parameters_cs":[{"name":"","range":"0 ° až 360 °","cmc":"0,02°"}],"technique":"porównanie z cyfrowym pochyłomierzem lub obrotowym stołem podziałowym","technique_en":"comparison with a digital inclinometer or rotary index table","technique_zh":"与数字倾角仪或旋转分度台比较","technique_cs":"porovnání s digitálním sklonoměrem nebo otočným dělicím stolkem","techniques":["porównanie z cyfrowym pochyłomierzem lub obrotowym stołem podziałowym"],"techniques_en":["comparison with a digital inclinometer or rotary index table"],"techniques_zh":["与数字倾角仪或旋转分度台比较"],"techniques_cs":["porovnání s digitálním sklonoměrem nebo otočným dělicím stolkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – kąt płaski\nod 0 ° do 360 ° CMC 0,02°\nporównanie z cyfrowym pochyłomierzem lub obrotowym stołem podziałowym","reference":"I540 – 068 – 10","norm_bases":["I540 – 068 – 10"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: kąt płaski","regulatory_area_en":"CMC for the field of measured quantity: Plane angle","regulatory_area_zh":"被测量领域的CMC：平面角","regulatory_area_cs":"CMC pro obor měřené veličiny: Rovinný úhel","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Czujniki położenia i inklinometry Wzorcowanie – kąt płaski porównanie z cyfrowym pochyłomierzem lub obrotowym stołem podziałowym od 0 ° do 360 ° CMC 0,02° Snímače polohy a inklinoměry Kalibrace – rovinný úhel porovnání s digitálním sklonoměrem nebo otočným dělicím stolkem 0 ° až 360 ° CMC 0,02° I540 – 068 – 10 Czujniki polozenia i inklinometry Wzorcowanie – kat plaski porownanie z cyfrowym pochylomierzem lub obrotowym stolem podzialowym od 0 ° do 360 ° CMC 0,02° Snimace polohy a inklinomery Kalibrace – rovinny uhel porovnani s digitalnim sklonomerem nebo otocnym delicim stolkem 0 ° az 360 ° CMC 0,02° I540 – 068 – 10","search_en":"Sensors of position and inclinometers Calibration – plane angle comparison with a digital inclinometer or rotary index table 0 ° to 360 ° CMC 0,02° I540 – 068 – 10","search_zh":"位置传感器和倾角仪 校准 – 平面角 与数字倾角仪或旋转分度台比较 0 ° 至 360 ° CMC 0,02° I540 – 068 – 10","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4c680000337d7c7564ee5b54","lab_id":"6ade8b52ff06824761708141","country":"CZ","accr_number":"2405","accr_body":"ČIA","row_label":"1","test_object":"Mierniki i czujniki przyspieszenia udarów mechanicznych o przebiegu półsinusoidalnym","test_object_en":"Meters and sensors of half-sine wave mechanical shock acceleration","test_object_zh":"半正弦机械冲击加速度测量仪和传感器","test_object_cs":"Měřidla a snímače zrychlení mechanických rázů půlsinusového průběhu","methodology":"Wzorcowanie – ruch mechaniczny","methodology_en":"Calibration – mechanical motion","methodology_zh":"校准 – 机械运动","methodology_cs":"Kalibrace – mechanický pohyb","parameters":[{"name":"","range":"od 100 m·s⁻² do 1471 m·s⁻²","cmc":"1,0 %"},{"name":"","range":"od 1471 m·s⁻² do 2000 m·s⁻²","cmc":"1,5 %"},{"name":"","range":"od 2000 m·s⁻² do 40000 m·s⁻²","cmc":"1,8 %"}],"parameters_en":[{"name":"","range":"100 m·s⁻² to 1471 m·s⁻²","cmc":"1,0 %"},{"name":"","range":"1471 m·s⁻² to 2000 m·s⁻²","cmc":"1,5 %"},{"name":"","range":"2000 m·s⁻² to 40000 m·s⁻²","cmc":"1,8 %"}],"parameters_zh":[{"name":"","range":"100 m·s⁻² 至 1471 m·s⁻²","cmc":"1,0 %"},{"name":"","range":"1471 m·s⁻² 至 2000 m·s⁻²","cmc":"1,5 %"},{"name":"","range":"2000 m·s⁻² 至 40000 m·s⁻²","cmc":"1,8 %"}],"parameters_cs":[{"name":"","range":"100 m·s⁻² až 1471 m·s⁻²","cmc":"1,0 %"},{"name":"","range":"1471 m·s⁻² až 2000 m·s⁻²","cmc":"1,5 %"},{"name":"","range":"2000 m·s⁻² až 40000 m·s⁻²","cmc":"1,8 %"}],"technique":"porównanie z wzorcowym czujnikiem przyspieszenia","technique_en":"comparison with a standard acceleration sensor","technique_zh":"与标准加速度传感器比较","technique_cs":"porovnání s etalonovým snímačem zrychlení","techniques":["porównanie z wzorcowym czujnikiem przyspieszenia"],"techniques_en":["comparison with a standard acceleration sensor"],"techniques_zh":["与标准加速度传感器比较"],"techniques_cs":["porovnání s etalonovým snímačem zrychlení"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny\nZakres:\nod 100 m·s⁻² do 1471 m·s⁻² CMC 1,0 %\nod 1471 m·s⁻² do 2000 m·s⁻² CMC 1,5 %\nod 2000 m·s⁻² do 40000 m·s⁻² CMC 1,8 %\nporównanie z wzorcowym czujnikiem przyspieszenia","reference":"I 540 – 068 – 43","norm_bases":["I 540 – 068 – 43"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion","regulatory_area_zh":"被测量领域的CMC：机械运动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb","flexible":false,"flexibility":null,"outside_premises":true,"note":"Można podawać także w jednostkach g, pC/g lub mV/g, przy czym 1 g = 9,807 m·s⁻²","note_en":"It can also be given in the units g, pC/g or mV/g, where 1 g = 9.807 m·s⁻²","note_zh":"也可用 g、pC/g 或 mV/g 表示，其中 1 g = 9,807 m·s⁻²","note_cs":"Možno uvádět i v jednotkách g, pC/g, resp. mV/g, přičemž 1 g = 9,807 m·s⁻²","search_text":"Mierniki i czujniki przyspieszenia udarów mechanicznych o przebiegu półsinusoidalnym Wzorcowanie – ruch mechaniczny porównanie z wzorcowym czujnikiem przyspieszenia od 100 m·s⁻² do 1471 m·s⁻² CMC 1,0 % od 1471 m·s⁻² do 2000 m·s⁻² CMC 1,5 % od 2000 m·s⁻² do 40000 m·s⁻² CMC 1,8 % Měřidla a snímače zrychlení mechanických rázů půlsinusového průběhu Kalibrace – mechanický pohyb porovnání s etalonovým snímačem zrychlení 100 m·s⁻² až 1471 m·s⁻² CMC 1,0 % 1471 m·s⁻² až 2000 m·s⁻² CMC 1,5 % 2000 m·s⁻² až 40000 m·s⁻² CMC 1,8 % I 540 – 068 – 43 Mierniki i czujniki przyspieszenia udarow mechanicznych o przebiegu polsinusoidalnym Wzorcowanie – ruch mechaniczny porownanie z wzorcowym czujnikiem przyspieszenia od 100 m·s⁻² do 1471 m·s⁻² CMC 1,0 % od 1471 m·s⁻² do 2000 m·s⁻² CMC 1,5 % od 2000 m·s⁻² do 40000 m·s⁻² CMC 1,8 % Meridla a snimace zrychleni mechanickych razu pulsinusoveho prubehu Kalibrace – mechanicky pohyb porovnani s etalonovym snimacem zrychleni 100 m·s⁻² az 1471 m·s⁻² CMC 1,0 % 1471 m·s⁻² az 2000 m·s⁻² CMC 1,5 % 2000 m·s⁻² az 40000 m·s⁻² CMC 1,8 % I 540 – 068 – 43","search_en":"Meters and sensors of half-sine wave mechanical shock acceleration Calibration – mechanical motion comparison with a standard acceleration sensor 100 m·s⁻² to 1471 m·s⁻² CMC 1,0 % 1471 m·s⁻² to 2000 m·s⁻² CMC 1,5 % 2000 m·s⁻² to 40000 m·s⁻² CMC 1,8 % I 540 – 068 – 43","search_zh":"半正弦机械冲击加速度测量仪和传感器 校准 – 机械运动 与标准加速度传感器比较 100 m·s⁻² 至 1471 m·s⁻² CMC 1,0 % 1471 m·s⁻² 至 2000 m·s⁻² CMC 1,5 % 2000 m·s⁻² 至 40000 m·s⁻² CMC 1,8 % I 540 – 068 – 43","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"47f1df847dc7515465bcd63d","lab_id":"6ade8b52ff06824761708141","country":"CZ","accr_number":"2405","accr_body":"ČIA","row_label":"2","test_object":"Przyspieszenie prostoliniowych drgań mechanicznych o przebiegu harmonicznym / Czujniki drgań, wibrometry, kalibratory drgań, generatory drgań","test_object_en":"Acceleration of linear mechanical vibrations of harmonic wave form / Vibration sensors, vibrometers, vibration calibrators, vibration generators","test_object_zh":"简谐直线机械振动加速度 / 振动传感器、测振仪、振动校准器、振动发生器","test_object_cs":"Zrychlení přímočarých mechanických vibrací harmonického průběhu / Snímače vibrací, vibrometry, kalibrátory vibrací, generátory vibrací","methodology":"Wzorcowanie – ruch mechaniczny","methodology_en":"Calibration – mechanical motion","methodology_zh":"校准 – 机械运动","methodology_cs":"Kalibrace – mechanický pohyb","parameters":[{"name":"5 Hz do 10 Hz","range":"od 0,1 m·s⁻² do 295 m·s⁻²","cmc":"2,0 %"},{"name":"10 Hz do 20 Hz","range":"od 0,1 m·s⁻² do 295 m·s⁻²","cmc":"1,0 %"},{"name":"20 Hz do 80 Hz","range":"od 0,1 m·s⁻² do 295 m·s⁻²","cmc":"0,75 %"},{"name":"80 Hz","range":"od 0,1 m·s⁻² do 295 m·s⁻²","cmc":"0,5 %"},{"name":"80 Hz do 1000 Hz","range":"od 0,1 m·s⁻² do 295 m·s⁻²","cmc":"0,75 %"},{"name":"1000 Hz do 5000 Hz","range":"od 0,1 m·s⁻² do 295 m·s⁻²","cmc":"1,0 %"},{"name":"5000 Hz do 10000 Hz","range":"od 0,1 m·s⁻² do 295 m·s⁻²","cmc":"2,0 %"}],"parameters_en":[{"name":"5 Hz to 10 Hz","range":"0,1 m·s⁻² to 295 m·s⁻²","cmc":"2,0 %"},{"name":"10 Hz to 20 Hz","range":"0,1 m·s⁻² to 295 m·s⁻²","cmc":"1,0 %"},{"name":"20 Hz to 80 Hz","range":"0,1 m·s⁻² to 295 m·s⁻²","cmc":"0,75 %"},{"name":"80 Hz","range":"0,1 m·s⁻² to 295 m·s⁻²","cmc":"0,5 %"},{"name":"80 Hz to 1000 Hz","range":"0,1 m·s⁻² to 295 m·s⁻²","cmc":"0,75 %"},{"name":"1000 Hz to 5000 Hz","range":"0,1 m·s⁻² to 295 m·s⁻²","cmc":"1,0 %"},{"name":"5000 Hz to 10000 Hz","range":"0,1 m·s⁻² to 295 m·s⁻²","cmc":"2,0 %"}],"parameters_zh":[{"name":"5 Hz 至 10 Hz","range":"0,1 m·s⁻² 至 295 m·s⁻²","cmc":"2,0 %"},{"name":"10 Hz 至 20 Hz","range":"0,1 m·s⁻² 至 295 m·s⁻²","cmc":"1,0 %"},{"name":"20 Hz 至 80 Hz","range":"0,1 m·s⁻² 至 295 m·s⁻²","cmc":"0,75 %"},{"name":"80 Hz","range":"0,1 m·s⁻² 至 295 m·s⁻²","cmc":"0,5 %"},{"name":"80 Hz 至 1000 Hz","range":"0,1 m·s⁻² 至 295 m·s⁻²","cmc":"0,75 %"},{"name":"1000 Hz 至 5000 Hz","range":"0,1 m·s⁻² 至 295 m·s⁻²","cmc":"1,0 %"},{"name":"5000 Hz 至 10000 Hz","range":"0,1 m·s⁻² 至 295 m·s⁻²","cmc":"2,0 %"}],"parameters_cs":[{"name":"5 Hz až 10 Hz","range":"0,1 m·s⁻² až 295 m·s⁻²","cmc":"2,0 %"},{"name":"10 Hz až 20 Hz","range":"0,1 m·s⁻² až 295 m·s⁻²","cmc":"1,0 %"},{"name":"20 Hz až 80 Hz","range":"0,1 m·s⁻² až 295 m·s⁻²","cmc":"0,75 %"},{"name":"80 Hz","range":"0,1 m·s⁻² až 295 m·s⁻²","cmc":"0,5 %"},{"name":"80 Hz až 1000 Hz","range":"0,1 m·s⁻² až 295 m·s⁻²","cmc":"0,75 %"},{"name":"1000 Hz až 5000 Hz","range":"0,1 m·s⁻² až 295 m·s⁻²","cmc":"1,0 %"},{"name":"5000 Hz až 10000 Hz","range":"0,1 m·s⁻² až 295 m·s⁻²","cmc":"2,0 %"}],"technique":"porównanie z wzorcowym czujnikiem przyspieszenia","technique_en":"comparison with a standard acceleration sensor","technique_zh":"与标准加速度传感器比较","technique_cs":"porovnání s etalonovým snímačem zrychlení","techniques":["porównanie z wzorcowym czujnikiem przyspieszenia"],"techniques_en":["comparison with a standard acceleration sensor"],"techniques_zh":["与标准加速度传感器比较"],"techniques_cs":["porovnání s etalonovým snímačem zrychlení"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny\nZakres:\n5 Hz do 10 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 2,0 %\n10 Hz do 20 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 1,0 %\n20 Hz do 80 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 0,75 %\n80 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 0,5 %\n80 Hz do 1000 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 0,75 %\n1000 Hz do 5000 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 1,0 %\n5000 Hz do 10000 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 2,0 %\nporównanie z wzorcowym czujnikiem przyspieszenia","reference":"I 540 – 068 – 45","norm_bases":["I 540 – 068 – 45"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion","regulatory_area_zh":"被测量领域的CMC：机械运动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wielkością mierzoną mogą być także prędkość, wychylenie, pod warunkiem generowania sygnału drgań o przebiegu harmonicznym o znanej częstotliwości. Można podawać także w jednostkach g, pC/g lub mV/g, przy czym 1 g = 9,807 m·s⁻²","note_en":"The measured quantity can also be velocity and displacement, assuming that a vibrational signal of the harmonic waveform is generated at a known frequency. It can also be given in the units g, pC/g or mV/g, where 1 g = 9.807 m·s⁻²","note_zh":"被测量也可以是速度、位移，前提是以已知频率产生简谐振动信号。也可用 g、pC/g 或 mV/g 表示，其中 1 g = 9,807 m·s⁻²","note_cs":"Měřenou veličinou mohou být i rychlost, výchylka za předpokladu generování vibračního signálu harmonického průběhu na známém kmitočtu. Možno uvádět i v jednotkách g, pC/g, resp. mV/g, přičemž 1 g = 9,807 m·s⁻²","search_text":"Przyspieszenie prostoliniowych drgań mechanicznych o przebiegu harmonicznym / Czujniki drgań, wibrometry, kalibratory drgań, generatory drgań Wzorcowanie – ruch mechaniczny porównanie z wzorcowym czujnikiem przyspieszenia 5 Hz do 10 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 2,0 % 10 Hz do 20 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 1,0 % 20 Hz do 80 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 0,75 % 80 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 0,5 % 80 Hz do 1000 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 0,75 % 1000 Hz do 5000 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 1,0 % 5000 Hz do 10000 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 2,0 % Zrychlení přímočarých mechanických vibrací harmonického průběhu / Snímače vibrací, vibrometry, kalibrátory vibrací, generátory vibrací Kalibrace – mechanický pohyb porovnání s etalonovým snímačem zrychlení 5 Hz až 10 Hz 0,1 m·s⁻² až 295 m·s⁻² CMC 2,0 % 10 Hz až 20 Hz 0,1 m·s⁻² až 295 m·s⁻² CMC 1,0 % 20 Hz až 80 Hz 0,1 m·s⁻² až 295 m·s⁻² CMC 0,75 % 80 Hz 0,1 m·s⁻² až 295 m·s⁻² CMC 0,5 % 80 Hz až 1000 Hz 0,1 m·s⁻² až 295 m·s⁻² CMC 0,75 % 1000 Hz až 5000 Hz 0,1 m·s⁻² až 295 m·s⁻² CMC 1,0 % 5000 Hz až 10000 Hz 0,1 m·s⁻² až 295 m·s⁻² CMC 2,0 % I 540 – 068 – 45 Przyspieszenie prostoliniowych drgan mechanicznych o przebiegu harmonicznym / Czujniki drgan, wibrometry, kalibratory drgan, generatory drgan Wzorcowanie – ruch mechaniczny porownanie z wzorcowym czujnikiem przyspieszenia 5 Hz do 10 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 2,0 % 10 Hz do 20 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 1,0 % 20 Hz do 80 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 0,75 % 80 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 0,5 % 80 Hz do 1000 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 0,75 % 1000 Hz do 5000 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 1,0 % 5000 Hz do 10000 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 2,0 % Zrychleni primocarych mechanickych vibraci harmonickeho prubehu / Snimace vibraci, vibrometry, kalibratory vibraci, generatory vibraci Kalibrace – mechanicky pohyb porovnani s etalonovym snimacem zrychleni 5 Hz az 10 Hz 0,1 m·s⁻² az 295 m·s⁻² CMC 2,0 % 10 Hz az 20 Hz 0,1 m·s⁻² az 295 m·s⁻² CMC 1,0 % 20 Hz az 80 Hz 0,1 m·s⁻² az 295 m·s⁻² CMC 0,75 % 80 Hz 0,1 m·s⁻² az 295 m·s⁻² CMC 0,5 % 80 Hz az 1000 Hz 0,1 m·s⁻² az 295 m·s⁻² CMC 0,75 % 1000 Hz az 5000 Hz 0,1 m·s⁻² az 295 m·s⁻² CMC 1,0 % 5000 Hz az 10000 Hz 0,1 m·s⁻² az 295 m·s⁻² CMC 2,0 % I 540 – 068 – 45","search_en":"Acceleration of linear mechanical vibrations of harmonic wave form / Vibration sensors, vibrometers, vibration calibrators, vibration generators Calibration – mechanical motion comparison with a standard acceleration sensor 5 Hz to 10 Hz 0,1 m·s⁻² to 295 m·s⁻² CMC 2,0 % 10 Hz to 20 Hz 0,1 m·s⁻² to 295 m·s⁻² CMC 1,0 % 20 Hz to 80 Hz 0,1 m·s⁻² to 295 m·s⁻² CMC 0,75 % 80 Hz 0,1 m·s⁻² to 295 m·s⁻² CMC 0,5 % 80 Hz to 1000 Hz 0,1 m·s⁻² to 295 m·s⁻² CMC 0,75 % 1000 Hz to 5000 Hz 0,1 m·s⁻² to 295 m·s⁻² CMC 1,0 % 5000 Hz to 10000 Hz 0,1 m·s⁻² to 295 m·s⁻² CMC 2,0 % I 540 – 068 – 45","search_zh":"简谐直线机械振动加速度 / 振动传感器、测振仪、振动校准器、振动发生器 校准 – 机械运动 与标准加速度传感器比较 5 Hz 至 10 Hz 0,1 m·s⁻² 至 295 m·s⁻² CMC 2,0 % 10 Hz 至 20 Hz 0,1 m·s⁻² 至 295 m·s⁻² CMC 1,0 % 20 Hz 至 80 Hz 0,1 m·s⁻² 至 295 m·s⁻² CMC 0,75 % 80 Hz 0,1 m·s⁻² 至 295 m·s⁻² CMC 0,5 % 80 Hz 至 1000 Hz 0,1 m·s⁻² 至 295 m·s⁻² CMC 0,75 % 1000 Hz 至 5000 Hz 0,1 m·s⁻² 至 295 m·s⁻² CMC 1,0 % 5000 Hz 至 10000 Hz 0,1 m·s⁻² 至 295 m·s⁻² CMC 2,0 % I 540 – 068 – 45","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4874a46efb5468c8eac12600","lab_id":"6ade8b52ff06824761708141","country":"CZ","accr_number":"2405","accr_body":"ČIA","row_label":"3","test_object":"Czułość czujników drgań i wibrometrów","test_object_en":"Sensitivity of vibration sensors and vibrometers","test_object_zh":"振动传感器和测振仪的灵敏度","test_object_cs":"Citlivost snímačů vibrací a vibrometrů","methodology":"Wzorcowanie – ruch mechaniczny","methodology_en":"Calibration – mechanical motion","methodology_zh":"校准 – 机械运动","methodology_cs":"Kalibrace – mechanický pohyb","parameters":[{"name":"5 Hz do 10 Hz","range":"od 0,01 mV/(m·s⁻²) do 10000 mV/(m·s⁻²)","cmc":"2,0 %"},{"name":"10 Hz do 20 Hz","range":"od 0,01 mV/(m·s⁻²) do 10000 mV/(m·s⁻²)","cmc":"1,0 %"},{"name":"20 Hz do 80 Hz","range":"od 0,01 mV/(m·s⁻²) do 10000 mV/(m·s⁻²)","cmc":"0,75 %"},{"name":"80 Hz","range":"od 0,01 mV/(m·s⁻²) do 10000 mV/(m·s⁻²)","cmc":"0,5 %"},{"name":"80 Hz do 1000 Hz","range":"od 0,01 mV/(m·s⁻²) do 10000 mV/(m·s⁻²)","cmc":"0,75 %"},{"name":"1000 Hz do 5000 Hz","range":"od 0,01 mV/(m·s⁻²) do 10000 mV/(m·s⁻²)","cmc":"1,0 %"},{"name":"5000 Hz do 10000 Hz","range":"od 0,01 mV/(m·s⁻²) do 10000 mV/(m·s⁻²)","cmc":"2,0 %"},{"name":"5 Hz do 10 Hz","range":"od 0,01 pC/(m·s⁻²) do 1000 pC/(m·s⁻²)","cmc":"2,0 %"},{"name":"10 Hz do 20 Hz","range":"od 0,01 pC/(m·s⁻²) do 1000 pC/(m·s⁻²)","cmc":"1,0 %"},{"name":"20 Hz do 80 Hz","range":"od 0,01 pC/(m·s⁻²) do 1000 pC/(m·s⁻²)","cmc":"0,75 %"},{"name":"80 Hz","range":"od 0,01 pC/(m·s⁻²) do 1000 pC/(m·s⁻²)","cmc":"0,5 %"},{"name":"80 Hz do 1000 Hz","range":"od 0,01 pC/(m·s⁻²) do 1000 pC/(m·s⁻²)","cmc":"0,75 %"},{"name":"1000 Hz do 5000 Hz","range":"od 0,01 pC/(m·s⁻²) do 1000 pC/(m·s⁻²)","cmc":"1,0 %"},{"name":"5000 Hz do 10000 Hz","range":"od 0,01 pC/(m·s⁻²) do 1000 pC/(m·s⁻²)","cmc":"2,0 %"},{"name":"5 Hz do 10 Hz","range":"od 0,01 mV/(m·s⁻¹) do 10000 mV/(m·s⁻¹)","cmc":"2,0 %"},{"name":"10 Hz do 20 Hz","range":"od 0,01 mV/(m·s⁻¹) do 10000 mV/(m·s⁻¹)","cmc":"1,0 %"},{"name":"20 Hz do 80 Hz","range":"od 0,01 mV/(m·s⁻¹) do 10000 mV/(m·s⁻¹)","cmc":"0,75 %"},{"name":"80 Hz","range":"od 0,01 mV/(m·s⁻¹) do 10000 mV/(m·s⁻¹)","cmc":"0,5 %"},{"name":"80 Hz do 1000 Hz","range":"od 0,01 mV/(m·s⁻¹) do 10000 mV/(m·s⁻¹)","cmc":"0,75 %"},{"name":"1000 Hz do 5000 Hz","range":"od 0,01 mV/(m·s⁻¹) do 10000 mV/(m·s⁻¹)","cmc":"1,0 %"},{"name":"5000 Hz do 10000 Hz","range":"od 0,01 mV/(m·s⁻¹) do 10000 mV/(m·s⁻¹)","cmc":"2,0 %"},{"name":"5 Hz do 10 Hz","range":"od 0,01 mV/m do 10000 mV/m","cmc":"2,0 %"},{"name":"10 Hz do 20 Hz","range":"od 0,01 mV/m do 10000 mV/m","cmc":"1,0 %"},{"name":"20 Hz do 80 Hz","range":"od 0,01 mV/m do 10000 mV/m","cmc":"0,75 %"},{"name":"80 Hz","range":"od 0,01 mV/m do 10000 mV/m","cmc":"0,5 %"},{"name":"80 Hz do 1000 Hz","range":"od 0,01 mV/m do 10000 mV/m","cmc":"0,75 %"},{"name":"1000 Hz do 5000 Hz","range":"od 0,01 mV/m do 10000 mV/m","cmc":"1,0 %"},{"name":"5000 Hz do 10000 Hz","range":"od 0,01 mV/m do 10000 mV/m","cmc":"2,0 %"}],"parameters_en":[{"name":"5 Hz to 10 Hz","range":"0,01 mV/(m·s⁻²) to 10000 mV/(m·s⁻²)","cmc":"2,0 %"},{"name":"10 Hz to 20 Hz","range":"0,01 mV/(m·s⁻²) to 10000 mV/(m·s⁻²)","cmc":"1,0 %"},{"name":"20 Hz to 80 Hz","range":"0,01 mV/(m·s⁻²) to 10000 mV/(m·s⁻²)","cmc":"0,75 %"},{"name":"80 Hz","range":"0,01 mV/(m·s⁻²) to 10000 mV/(m·s⁻²)","cmc":"0,5 %"},{"name":"80 Hz to 1000 Hz","range":"0,01 mV/(m·s⁻²) to 10000 mV/(m·s⁻²)","cmc":"0,75 %"},{"name":"1000 Hz to 5000 Hz","range":"0,01 mV/(m·s⁻²) to 10000 mV/(m·s⁻²)","cmc":"1,0 %"},{"name":"5000 Hz to 10000 Hz","range":"0,01 mV/(m·s⁻²) to 10000 mV/(m·s⁻²)","cmc":"2,0 %"},{"name":"5 Hz to 10 Hz","range":"0,01 pC/(m·s⁻²) to 1000 pC/(m·s⁻²)","cmc":"2,0 %"},{"name":"10 Hz to 20 Hz","range":"0,01 pC/(m·s⁻²) to 1000 pC/(m·s⁻²)","cmc":"1,0 %"},{"name":"20 Hz to 80 Hz","range":"0,01 pC/(m·s⁻²) to 1000 pC/(m·s⁻²)","cmc":"0,75 %"},{"name":"80 Hz","range":"0,01 pC/(m·s⁻²) to 1000 pC/(m·s⁻²)","cmc":"0,5 %"},{"name":"80 Hz to 1000 Hz","range":"0,01 pC/(m·s⁻²) to 1000 pC/(m·s⁻²)","cmc":"0,75 %"},{"name":"1000 Hz to 5000 Hz","range":"0,01 pC/(m·s⁻²) to 1000 pC/(m·s⁻²)","cmc":"1,0 %"},{"name":"5000 Hz to 10000 Hz","range":"0,01 pC/(m·s⁻²) to 1000 pC/(m·s⁻²)","cmc":"2,0 %"},{"name":"5 Hz to 10 Hz","range":"0,01 mV/(m·s⁻¹) to 10000 mV/(m·s⁻¹)","cmc":"2,0 %"},{"name":"10 Hz to 20 Hz","range":"0,01 mV/(m·s⁻¹) to 10000 mV/(m·s⁻¹)","cmc":"1,0 %"},{"name":"20 Hz to 80 Hz","range":"0,01 mV/(m·s⁻¹) to 10000 mV/(m·s⁻¹)","cmc":"0,75 %"},{"name":"80 Hz","range":"0,01 mV/(m·s⁻¹) to 10000 mV/(m·s⁻¹)","cmc":"0,5 %"},{"name":"80 Hz to 1000 Hz","range":"0,01 mV/(m·s⁻¹) to 10000 mV/(m·s⁻¹)","cmc":"0,75 %"},{"name":"1000 Hz to 5000 Hz","range":"0,01 mV/(m·s⁻¹) to 10000 mV/(m·s⁻¹)","cmc":"1,0 %"},{"name":"5000 Hz to 10000 Hz","range":"0,01 mV/(m·s⁻¹) to 10000 mV/(m·s⁻¹)","cmc":"2,0 %"},{"name":"5 Hz to 10 Hz","range":"0,01 mV/m to 10000 mV/m","cmc":"2,0 %"},{"name":"10 Hz to 20 Hz","range":"0,01 mV/m to 10000 mV/m","cmc":"1,0 %"},{"name":"20 Hz to 80 Hz","range":"0,01 mV/m to 10000 mV/m","cmc":"0,75 %"},{"name":"80 Hz","range":"0,01 mV/m to 10000 mV/m","cmc":"0,5 %"},{"name":"80 Hz to 1000 Hz","range":"0,01 mV/m to 10000 mV/m","cmc":"0,75 %"},{"name":"1000 Hz to 5000 Hz","range":"0,01 mV/m to 10000 mV/m","cmc":"1,0 %"},{"name":"5000 Hz to 10000 Hz","range":"0,01 mV/m to 10000 mV/m","cmc":"2,0 %"}],"parameters_zh":[{"name":"5 Hz 至 10 Hz","range":"0,01 mV/(m·s⁻²) 至 10000 mV/(m·s⁻²)","cmc":"2,0 %"},{"name":"10 Hz 至 20 Hz","range":"0,01 mV/(m·s⁻²) 至 10000 mV/(m·s⁻²)","cmc":"1,0 %"},{"name":"20 Hz 至 80 Hz","range":"0,01 mV/(m·s⁻²) 至 10000 mV/(m·s⁻²)","cmc":"0,75 %"},{"name":"80 Hz","range":"0,01 mV/(m·s⁻²) 至 10000 mV/(m·s⁻²)","cmc":"0,5 %"},{"name":"80 Hz 至 1000 Hz","range":"0,01 mV/(m·s⁻²) 至 10000 mV/(m·s⁻²)","cmc":"0,75 %"},{"name":"1000 Hz 至 5000 Hz","range":"0,01 mV/(m·s⁻²) 至 10000 mV/(m·s⁻²)","cmc":"1,0 %"},{"name":"5000 Hz 至 10000 Hz","range":"0,01 mV/(m·s⁻²) 至 10000 mV/(m·s⁻²)","cmc":"2,0 %"},{"name":"5 Hz 至 10 Hz","range":"0,01 pC/(m·s⁻²) 至 1000 pC/(m·s⁻²)","cmc":"2,0 %"},{"name":"10 Hz 至 20 Hz","range":"0,01 pC/(m·s⁻²) 至 1000 pC/(m·s⁻²)","cmc":"1,0 %"},{"name":"20 Hz 至 80 Hz","range":"0,01 pC/(m·s⁻²) 至 1000 pC/(m·s⁻²)","cmc":"0,75 %"},{"name":"80 Hz","range":"0,01 pC/(m·s⁻²) 至 1000 pC/(m·s⁻²)","cmc":"0,5 %"},{"name":"80 Hz 至 1000 Hz","range":"0,01 pC/(m·s⁻²) 至 1000 pC/(m·s⁻²)","cmc":"0,75 %"},{"name":"1000 Hz 至 5000 Hz","range":"0,01 pC/(m·s⁻²) 至 1000 pC/(m·s⁻²)","cmc":"1,0 %"},{"name":"5000 Hz 至 10000 Hz","range":"0,01 pC/(m·s⁻²) 至 1000 pC/(m·s⁻²)","cmc":"2,0 %"},{"name":"5 Hz 至 10 Hz","range":"0,01 mV/(m·s⁻¹) 至 10000 mV/(m·s⁻¹)","cmc":"2,0 %"},{"name":"10 Hz 至 20 Hz","range":"0,01 mV/(m·s⁻¹) 至 10000 mV/(m·s⁻¹)","cmc":"1,0 %"},{"name":"20 Hz 至 80 Hz","range":"0,01 mV/(m·s⁻¹) 至 10000 mV/(m·s⁻¹)","cmc":"0,75 %"},{"name":"80 Hz","range":"0,01 mV/(m·s⁻¹) 至 10000 mV/(m·s⁻¹)","cmc":"0,5 %"},{"name":"80 Hz 至 1000 Hz","range":"0,01 mV/(m·s⁻¹) 至 10000 mV/(m·s⁻¹)","cmc":"0,75 %"},{"name":"1000 Hz 至 5000 Hz","range":"0,01 mV/(m·s⁻¹) 至 10000 mV/(m·s⁻¹)","cmc":"1,0 %"},{"name":"5000 Hz 至 10000 Hz","range":"0,01 mV/(m·s⁻¹) 至 10000 mV/(m·s⁻¹)","cmc":"2,0 %"},{"name":"5 Hz 至 10 Hz","range":"0,01 mV/m 至 10000 mV/m","cmc":"2,0 %"},{"name":"10 Hz 至 20 Hz","range":"0,01 mV/m 至 10000 mV/m","cmc":"1,0 %"},{"name":"20 Hz 至 80 Hz","range":"0,01 mV/m 至 10000 mV/m","cmc":"0,75 %"},{"name":"80 Hz","range":"0,01 mV/m 至 10000 mV/m","cmc":"0,5 %"},{"name":"80 Hz 至 1000 Hz","range":"0,01 mV/m 至 10000 mV/m","cmc":"0,75 %"},{"name":"1000 Hz 至 5000 Hz","range":"0,01 mV/m 至 10000 mV/m","cmc":"1,0 %"},{"name":"5000 Hz 至 10000 Hz","range":"0,01 mV/m 至 10000 mV/m","cmc":"2,0 %"}],"parameters_cs":[{"name":"5 Hz až 10 Hz","range":"0,01 mV/(m·s⁻²) až 10000 mV/(m·s⁻²)","cmc":"2,0 %"},{"name":"10 Hz až 20 Hz","range":"0,01 mV/(m·s⁻²) až 10000 mV/(m·s⁻²)","cmc":"1,0 %"},{"name":"20 Hz až 80 Hz","range":"0,01 mV/(m·s⁻²) až 10000 mV/(m·s⁻²)","cmc":"0,75 %"},{"name":"80 Hz","range":"0,01 mV/(m·s⁻²) až 10000 mV/(m·s⁻²)","cmc":"0,5 %"},{"name":"80 Hz až 1000 Hz","range":"0,01 mV/(m·s⁻²) až 10000 mV/(m·s⁻²)","cmc":"0,75 %"},{"name":"1000 Hz až 5000 Hz","range":"0,01 mV/(m·s⁻²) až 10000 mV/(m·s⁻²)","cmc":"1,0 %"},{"name":"5000 Hz až 10000 Hz","range":"0,01 mV/(m·s⁻²) až 10000 mV/(m·s⁻²)","cmc":"2,0 %"},{"name":"5 Hz až 10 Hz","range":"0,01 pC/(m·s⁻²) až 1000 pC/(m·s⁻²)","cmc":"2,0 %"},{"name":"10 Hz až 20 Hz","range":"0,01 pC/(m·s⁻²) až 1000 pC/(m·s⁻²)","cmc":"1,0 %"},{"name":"20 Hz až 80 Hz","range":"0,01 pC/(m·s⁻²) až 1000 pC/(m·s⁻²)","cmc":"0,75 %"},{"name":"80 Hz","range":"0,01 pC/(m·s⁻²) až 1000 pC/(m·s⁻²)","cmc":"0,5 %"},{"name":"80 Hz až 1000 Hz","range":"0,01 pC/(m·s⁻²) až 1000 pC/(m·s⁻²)","cmc":"0,75 %"},{"name":"1000 Hz až 5000 Hz","range":"0,01 pC/(m·s⁻²) až 1000 pC/(m·s⁻²)","cmc":"1,0 %"},{"name":"5000 Hz až 10000 Hz","range":"0,01 pC/(m·s⁻²) až 1000 pC/(m·s⁻²)","cmc":"2,0 %"},{"name":"5 Hz až 10 Hz","range":"0,01 mV/(m·s⁻¹) až 10000 mV/(m·s⁻¹)","cmc":"2,0 %"},{"name":"10 Hz až 20 Hz","range":"0,01 mV/(m·s⁻¹) až 10000 mV/(m·s⁻¹)","cmc":"1,0 %"},{"name":"20 Hz až 80 Hz","range":"0,01 mV/(m·s⁻¹) až 10000 mV/(m·s⁻¹)","cmc":"0,75 %"},{"name":"80 Hz","range":"0,01 mV/(m·s⁻¹) až 10000 mV/(m·s⁻¹)","cmc":"0,5 %"},{"name":"80 Hz až 1000 Hz","range":"0,01 mV/(m·s⁻¹) až 10000 mV/(m·s⁻¹)","cmc":"0,75 %"},{"name":"1000 Hz až 5000 Hz","range":"0,01 mV/(m·s⁻¹) až 10000 mV/(m·s⁻¹)","cmc":"1,0 %"},{"name":"5000 Hz až 10000 Hz","range":"0,01 mV/(m·s⁻¹) až 10000 mV/(m·s⁻¹)","cmc":"2,0 %"},{"name":"5 Hz až 10 Hz","range":"0,01 mV/m až 10000 mV/m","cmc":"2,0 %"},{"name":"10 Hz až 20 Hz","range":"0,01 mV/m až 10000 mV/m","cmc":"1,0 %"},{"name":"20 Hz až 80 Hz","range":"0,01 mV/m až 10000 mV/m","cmc":"0,75 %"},{"name":"80 Hz","range":"0,01 mV/m až 10000 mV/m","cmc":"0,5 %"},{"name":"80 Hz až 1000 Hz","range":"0,01 mV/m až 10000 mV/m","cmc":"0,75 %"},{"name":"1000 Hz až 5000 Hz","range":"0,01 mV/m až 10000 mV/m","cmc":"1,0 %"},{"name":"5000 Hz až 10000 Hz","range":"0,01 mV/m až 10000 mV/m","cmc":"2,0 %"}],"technique":"porównanie z wzorcem drgań","technique_en":"comparison with a vibration standard","technique_zh":"与振动标准器比较","technique_cs":"porovnání s etalonem vibrací","techniques":["porównanie z wzorcem drgań"],"techniques_en":["comparison with a vibration standard"],"techniques_zh":["与振动标准器比较"],"techniques_cs":["porovnání s etalonem vibrací"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny\nZakres:\n5 Hz do 10 Hz od 0,01 mV/(m·s⁻²) do 10000 mV/(m·s⁻²) CMC 2,0 %\n10 Hz do 20 Hz od 0,01 mV/(m·s⁻²) do 10000 mV/(m·s⁻²) CMC 1,0 %\n20 Hz do 80 Hz od 0,01 mV/(m·s⁻²) do 10000 mV/(m·s⁻²) CMC 0,75 %\n80 Hz od 0,01 mV/(m·s⁻²) do 10000 mV/(m·s⁻²) CMC 0,5 %\n80 Hz do 1000 Hz od 0,01 mV/(m·s⁻²) do 10000 mV/(m·s⁻²) CMC 0,75 %\n1000 Hz do 5000 Hz od 0,01 mV/(m·s⁻²) do 10000 mV/(m·s⁻²) CMC 1,0 %\n5000 Hz do 10000 Hz od 0,01 mV/(m·s⁻²) do 10000 mV/(m·s⁻²) CMC 2,0 %\n5 Hz do 10 Hz od 0,01 pC/(m·s⁻²) do 1000 pC/(m·s⁻²) CMC 2,0 %\n10 Hz do 20 Hz od 0,01 pC/(m·s⁻²) do 1000 pC/(m·s⁻²) CMC 1,0 %\n20 Hz do 80 Hz od 0,01 pC/(m·s⁻²) do 1000 pC/(m·s⁻²) CMC 0,75 %\n80 Hz od 0,01 pC/(m·s⁻²) do 1000 pC/(m·s⁻²) CMC 0,5 %\n80 Hz do 1000 Hz od 0,01 pC/(m·s⁻²) do 1000 pC/(m·s⁻²) CMC 0,75 %\n1000 Hz do 5000 Hz od 0,01 pC/(m·s⁻²) do 1000 pC/(m·s⁻²) CMC 1,0 %\n5000 Hz do 10000 Hz od 0,01 pC/(m·s⁻²) do 1000 pC/(m·s⁻²) CMC 2,0 %\n5 Hz do 10 Hz od 0,01 mV/(m·s⁻¹) do 10000 mV/(m·s⁻¹) CMC 2,0 %\n10 Hz do 20 Hz od 0,01 mV/(m·s⁻¹) do 10000 mV/(m·s⁻¹) CMC 1,0 %\n20 Hz do 80 Hz od 0,01 mV/(m·s⁻¹) do 10000 mV/(m·s⁻¹) CMC 0,75 %\n80 Hz od 0,01 mV/(m·s⁻¹) do 10000 mV/(m·s⁻¹) CMC 0,5 %\n80 Hz do 1000 Hz od 0,01 mV/(m·s⁻¹) do 10000 mV/(m·s⁻¹) CMC 0,75 %\n1000 Hz do 5000 Hz od 0,01 mV/(m·s⁻¹) do 10000 mV/(m·s⁻¹) CMC 1,0 %\n5000 Hz do 10000 Hz od 0,01 mV/(m·s⁻¹) do 10000 mV/(m·s⁻¹) CMC 2,0 %\n5 Hz do 10 Hz od 0,01 mV/m do 10000 mV/m CMC 2,0 %\n10 Hz do 20 Hz od 0,01 mV/m do 10000 mV/m CMC 1,0 %\n20 Hz do 80 Hz od 0,01 mV/m do 10000 mV/m CMC 0,75 %\n80 Hz od 0,01 mV/m do 10000 mV/m CMC 0,5 %\n80 Hz do 1000 Hz od 0,01 mV/m do 10000 mV/m CMC 0,75 %\n1000 Hz do 5000 Hz od 0,01 mV/m do 10000 mV/m CMC 1,0 %\n5000 Hz do 10000 Hz od 0,01 mV/m do 10000 mV/m CMC 2,0 %\nporównanie z wzorcem drgań","reference":"I 540 – 068 – 45","norm_bases":["I 540 – 068 – 45"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion","regulatory_area_zh":"被测量领域的CMC：机械运动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wielkością mierzoną mogą być także prędkość, wychylenie, pod warunkiem generowania sygnału drgań o przebiegu harmonicznym o znanej częstotliwości. Można podawać także w jednostkach g, pC/g lub mV/g, przy czym 1 g = 9,807 m·s⁻²","note_en":"The measured quantity can also be velocity and displacement, assuming that a vibrational signal of the harmonic waveform is generated at a known frequency. It can also be given in the units g, pC/g or mV/g, where 1 g = 9.807 m·s⁻²","note_zh":"被测量也可以是速度、位移，前提是以已知频率产生简谐振动信号。也可用 g、pC/g 或 mV/g 表示，其中 1 g = 9,807 m·s⁻²","note_cs":"Měřenou veličinou mohou být i rychlost, výchylka za předpokladu generování vibračního signálu harmonického průběhu na známém kmitočtu. Možno uvádět i v jednotkách g, pC/g, resp. mV/g, přičemž 1 g = 9,807 m·s⁻²","search_text":"Czułość czujników drgań i wibrometrów Wzorcowanie – ruch mechaniczny porównanie z wzorcem drgań 5 Hz do 10 Hz od 0,01 mV/(m·s⁻²) do 10000 mV/(m·s⁻²) CMC 2,0 % 10 Hz do 20 Hz od 0,01 mV/(m·s⁻²) do 10000 mV/(m·s⁻²) CMC 1,0 % 20 Hz do 80 Hz od 0,01 mV/(m·s⁻²) do 10000 mV/(m·s⁻²) CMC 0,75 % 80 Hz od 0,01 mV/(m·s⁻²) do 10000 mV/(m·s⁻²) CMC 0,5 % 80 Hz do 1000 Hz od 0,01 mV/(m·s⁻²) do 10000 mV/(m·s⁻²) CMC 0,75 % 1000 Hz do 5000 Hz od 0,01 mV/(m·s⁻²) do 10000 mV/(m·s⁻²) CMC 1,0 % 5000 Hz do 10000 Hz od 0,01 mV/(m·s⁻²) do 10000 mV/(m·s⁻²) CMC 2,0 % 5 Hz do 10 Hz od 0,01 pC/(m·s⁻²) do 1000 pC/(m·s⁻²) CMC 2,0 % 10 Hz do 20 Hz od 0,01 pC/(m·s⁻²) do 1000 pC/(m·s⁻²) CMC 1,0 % 20 Hz do 80 Hz od 0,01 pC/(m·s⁻²) do 1000 pC/(m·s⁻²) CMC 0,75 % 80 Hz od 0,01 pC/(m·s⁻²) do 1000 pC/(m·s⁻²) CMC 0,5 % 80 Hz do 1000 Hz od 0,01 pC/(m·s⁻²) do 1000 pC/(m·s⁻²) CMC 0,75 % 1000 Hz do 5000 Hz od 0,01 pC/(m·s⁻²) do 1000 pC/(m·s⁻²) CMC 1,0 % 5000 Hz do 10000 Hz od 0,01 pC/(m·s⁻²) do 1000 pC/(m·s⁻²) CMC 2,0 % 5 Hz do 10 Hz od 0,01 mV/(m·s⁻¹) do 10000 mV/(m·s⁻¹) CMC 2,0 % 10 Hz do 20 Hz od 0,01 mV/(m·s⁻¹) do 10000 mV/(m·s⁻¹) CMC 1,0 % 20 Hz do 80 Hz od 0,01 mV/(m·s⁻¹) do 10000 mV/(m·s⁻¹) CMC 0,75 % 80 Hz od 0,01 mV/(m·s⁻¹) do 10000 mV/(m·s⁻¹) CMC 0,5 % 80 Hz do 1000 Hz od 0,01 mV/(m·s⁻¹) do 10000 mV/(m·s⁻¹) CMC 0,75 % 1000 Hz do 5000 Hz od 0,01 mV/(m·s⁻¹) do 10000 mV/(m·s⁻¹) CMC 1,0 % 5000 Hz do 10000 Hz od 0,01 mV/(m·s⁻¹) do 10000 mV/(m·s⁻¹) CMC 2,0 % 5 Hz do 10 Hz od 0,01 mV/m do 10000 mV/m CMC 2,0 % 10 Hz do 20 Hz od 0,01 mV/m do 10000 mV/m CMC 1,0 % 20 Hz do 80 Hz od 0,01 mV/m do 10000 mV/m CMC 0,75 % 80 Hz od 0,01 mV/m do 10000 mV/m CMC 0,5 % 80 Hz do 1000 Hz od 0,01 mV/m do 10000 mV/m CMC 0,75 % 1000 Hz do 5000 Hz od 0,01 mV/m do 10000 mV/m CMC 1,0 % 5000 Hz do 10000 Hz od 0,01 mV/m do 10000 mV/m CMC 2,0 % Citlivost snímačů vibrací a vibrometrů Kalibrace – mechanický pohyb porovnání s etalonem vibrací 5 Hz až 10 Hz 0,01 mV/(m·s⁻²) až 10000 mV/(m·s⁻²) CMC 2,0 % 10 Hz až 20 Hz 0,01 mV/(m·s⁻²) až 10000 mV/(m·s⁻²) CMC 1,0 % 20 Hz až 80 Hz 0,01 mV/(m·s⁻²) až 10000 mV/(m·s⁻²) CMC 0,75 % 80 Hz 0,01 mV/(m·s⁻²) až 10000 mV/(m·s⁻²) CMC 0,5 % 80 Hz až 1000 Hz 0,01 mV/(m·s⁻²) až 10000 mV/(m·s⁻²) CMC 0,75 % 1000 Hz až 5000 Hz 0,01 mV/(m·s⁻²) až 10000 mV/(m·s⁻²) CMC 1,0 % 5000 Hz až 10000 Hz 0,01 mV/(m·s⁻²) až 10000 mV/(m·s⁻²) CMC 2,0 % 5 Hz až 10 Hz 0,01 pC/(m·s⁻²) až 1000 pC/(m·s⁻²) CMC 2,0 % 10 Hz až 20 Hz 0,01 pC/(m·s⁻²) až 1000 pC/(m·s⁻²) CMC 1,0 % 20 Hz až 80 Hz 0,01 pC/(m·s⁻²) až 1000 pC/(m·s⁻²) CMC 0,75 % 80 Hz 0,01 pC/(m·s⁻²) až 1000 pC/(m·s⁻²) CMC 0,5 % 80 Hz až 1000 Hz 0,01 pC/(m·s⁻²) až 1000 pC/(m·s⁻²) CMC 0,75 % 1000 Hz až 5000 Hz 0,01 pC/(m·s⁻²) až 1000 pC/(m·s⁻²) CMC 1,0 % 5000 Hz až 10000 Hz 0,01 pC/(m·s⁻²) až 1000 pC/(m·s⁻²) CMC 2,0 % 5 Hz až 10 Hz 0,01 mV/(m·s⁻¹) až 10000 mV/(m·s⁻¹) CMC 2,0 % 10 Hz až 20 Hz 0,01 mV/(m·s⁻¹) až 10000 mV/(m·s⁻¹) CMC 1,0 % 20 Hz až 80 Hz 0,01 mV/(m·s⁻¹) až 10000 mV/(m·s⁻¹) CMC 0,75 % 80 Hz 0,01 mV/(m·s⁻¹) až 10000 mV/(m·s⁻¹) CMC 0,5 % 80 Hz až 1000 Hz 0,01 mV/(m·s⁻¹) až 10000 mV/(m·s⁻¹) CMC 0,75 % 1000 Hz až 5000 Hz 0,01 mV/(m·s⁻¹) až 10000 mV/(m·s⁻¹) CMC 1,0 % 5000 Hz až 10000 Hz 0,01 mV/(m·s⁻¹) až 10000 mV/(m·s⁻¹) CMC 2,0 % 5 Hz až 10 Hz 0,01 mV/m až 10000 mV/m CMC 2,0 % 10 Hz až 20 Hz 0,01 mV/m až 10000 mV/m CMC 1,0 % 20 Hz až 80 Hz 0,01 mV/m až 10000 mV/m CMC 0,75 % 80 Hz 0,01 mV/m až 10000 mV/m CMC 0,5 % 80 Hz až 1000 Hz 0,01 mV/m až 10000 mV/m CMC 0,75 % 1000 Hz až 5000 Hz 0,01 mV/m až 10000 mV/m CMC 1,0 % 5000 Hz až 10000 Hz 0,01 mV/m až 10000 mV/m CMC 2,0 % I 540 – 068 – 45 Czulosc czujnikow drgan i wibrometrow Wzorcowanie – ruch mechaniczny porownanie z wzorcem drgan 5 Hz do 10 Hz od 0,01 mV/(m·s⁻²) do 10000 mV/(m·s⁻²) CMC 2,0 % 10 Hz do 20 Hz od 0,01 mV/(m·s⁻²) do 10000 mV/(m·s⁻²) CMC 1,0 % 20 Hz do 80 Hz od 0,01 mV/(m·s⁻²) do 10000 mV/(m·s⁻²) CMC 0,75 % 80 Hz od 0,01 mV/(m·s⁻²) do 10000 mV/(m·s⁻²) CMC 0,5 % 80 Hz do 1000 Hz od 0,01 mV/(m·s⁻²) do 10000 mV/(m·s⁻²) CMC 0,75 % 1000 Hz do 5000 Hz od 0,01 mV/(m·s⁻²) do 10000 mV/(m·s⁻²) CMC 1,0 % 5000 Hz do 10000 Hz od 0,01 mV/(m·s⁻²) do 10000 mV/(m·s⁻²) CMC 2,0 % 5 Hz do 10 Hz od 0,01 pC/(m·s⁻²) do 1000 pC/(m·s⁻²) CMC 2,0 % 10 Hz do 20 Hz od 0,01 pC/(m·s⁻²) do 1000 pC/(m·s⁻²) CMC 1,0 % 20 Hz do 80 Hz od 0,01 pC/(m·s⁻²) do 1000 pC/(m·s⁻²) CMC 0,75 % 80 Hz od 0,01 pC/(m·s⁻²) do 1000 pC/(m·s⁻²) CMC 0,5 % 80 Hz do 1000 Hz od 0,01 pC/(m·s⁻²) do 1000 pC/(m·s⁻²) CMC 0,75 % 1000 Hz do 5000 Hz od 0,01 pC/(m·s⁻²) do 1000 pC/(m·s⁻²) CMC 1,0 % 5000 Hz do 10000 Hz od 0,01 pC/(m·s⁻²) do 1000 pC/(m·s⁻²) CMC 2,0 % 5 Hz do 10 Hz od 0,01 mV/(m·s⁻¹) do 10000 mV/(m·s⁻¹) CMC 2,0 % 10 Hz do 20 Hz od 0,01 mV/(m·s⁻¹) do 10000 mV/(m·s⁻¹) CMC 1,0 % 20 Hz do 80 Hz od 0,01 mV/(m·s⁻¹) do 10000 mV/(m·s⁻¹) CMC 0,75 % 80 Hz od 0,01 mV/(m·s⁻¹) do 10000 mV/(m·s⁻¹) CMC 0,5 % 80 Hz do 1000 Hz od 0,01 mV/(m·s⁻¹) do 10000 mV/(m·s⁻¹) CMC 0,75 % 1000 Hz do 5000 Hz od 0,01 mV/(m·s⁻¹) do 10000 mV/(m·s⁻¹) CMC 1,0 % 5000 Hz do 10000 Hz od 0,01 mV/(m·s⁻¹) do 10000 mV/(m·s⁻¹) CMC 2,0 % 5 Hz do 10 Hz od 0,01 mV/m do 10000 mV/m CMC 2,0 % 10 Hz do 20 Hz od 0,01 mV/m do 10000 mV/m CMC 1,0 % 20 Hz do 80 Hz od 0,01 mV/m do 10000 mV/m CMC 0,75 % 80 Hz od 0,01 mV/m do 10000 mV/m CMC 0,5 % 80 Hz do 1000 Hz od 0,01 mV/m do 10000 mV/m CMC 0,75 % 1000 Hz do 5000 Hz od 0,01 mV/m do 10000 mV/m CMC 1,0 % 5000 Hz do 10000 Hz od 0,01 mV/m do 10000 mV/m CMC 2,0 % Citlivost snimacu vibraci a vibrometru Kalibrace – mechanicky pohyb porovnani s etalonem vibraci 5 Hz az 10 Hz 0,01 mV/(m·s⁻²) az 10000 mV/(m·s⁻²) CMC 2,0 % 10 Hz az 20 Hz 0,01 mV/(m·s⁻²) az 10000 mV/(m·s⁻²) CMC 1,0 % 20 Hz az 80 Hz 0,01 mV/(m·s⁻²) az 10000 mV/(m·s⁻²) CMC 0,75 % 80 Hz 0,01 mV/(m·s⁻²) az 10000 mV/(m·s⁻²) CMC 0,5 % 80 Hz az 1000 Hz 0,01 mV/(m·s⁻²) az 10000 mV/(m·s⁻²) CMC 0,75 % 1000 Hz az 5000 Hz 0,01 mV/(m·s⁻²) az 10000 mV/(m·s⁻²) CMC 1,0 % 5000 Hz az 10000 Hz 0,01 mV/(m·s⁻²) az 10000 mV/(m·s⁻²) CMC 2,0 % 5 Hz az 10 Hz 0,01 pC/(m·s⁻²) az 1000 pC/(m·s⁻²) CMC 2,0 % 10 Hz az 20 Hz 0,01 pC/(m·s⁻²) az 1000 pC/(m·s⁻²) CMC 1,0 % 20 Hz az 80 Hz 0,01 pC/(m·s⁻²) az 1000 pC/(m·s⁻²) CMC 0,75 % 80 Hz 0,01 pC/(m·s⁻²) az 1000 pC/(m·s⁻²) CMC 0,5 % 80 Hz az 1000 Hz 0,01 pC/(m·s⁻²) az 1000 pC/(m·s⁻²) CMC 0,75 % 1000 Hz az 5000 Hz 0,01 pC/(m·s⁻²) az 1000 pC/(m·s⁻²) CMC 1,0 % 5000 Hz az 10000 Hz 0,01 pC/(m·s⁻²) az 1000 pC/(m·s⁻²) CMC 2,0 % 5 Hz az 10 Hz 0,01 mV/(m·s⁻¹) az 10000 mV/(m·s⁻¹) CMC 2,0 % 10 Hz az 20 Hz 0,01 mV/(m·s⁻¹) az 10000 mV/(m·s⁻¹) CMC 1,0 % 20 Hz az 80 Hz 0,01 mV/(m·s⁻¹) az 10000 mV/(m·s⁻¹) CMC 0,75 % 80 Hz 0,01 mV/(m·s⁻¹) az 10000 mV/(m·s⁻¹) CMC 0,5 % 80 Hz az 1000 Hz 0,01 mV/(m·s⁻¹) az 10000 mV/(m·s⁻¹) CMC 0,75 % 1000 Hz az 5000 Hz 0,01 mV/(m·s⁻¹) az 10000 mV/(m·s⁻¹) CMC 1,0 % 5000 Hz az 10000 Hz 0,01 mV/(m·s⁻¹) az 10000 mV/(m·s⁻¹) CMC 2,0 % 5 Hz az 10 Hz 0,01 mV/m az 10000 mV/m CMC 2,0 % 10 Hz az 20 Hz 0,01 mV/m az 10000 mV/m CMC 1,0 % 20 Hz az 80 Hz 0,01 mV/m az 10000 mV/m CMC 0,75 % 80 Hz 0,01 mV/m az 10000 mV/m CMC 0,5 % 80 Hz az 1000 Hz 0,01 mV/m az 10000 mV/m CMC 0,75 % 1000 Hz az 5000 Hz 0,01 mV/m az 10000 mV/m CMC 1,0 % 5000 Hz az 10000 Hz 0,01 mV/m az 10000 mV/m CMC 2,0 % I 540 – 068 – 45","search_en":"Sensitivity of vibration sensors and vibrometers Calibration – mechanical motion comparison with a vibration standard 5 Hz to 10 Hz 0,01 mV/(m·s⁻²) to 10000 mV/(m·s⁻²) CMC 2,0 % 10 Hz to 20 Hz 0,01 mV/(m·s⁻²) to 10000 mV/(m·s⁻²) CMC 1,0 % 20 Hz to 80 Hz 0,01 mV/(m·s⁻²) to 10000 mV/(m·s⁻²) CMC 0,75 % 80 Hz 0,01 mV/(m·s⁻²) to 10000 mV/(m·s⁻²) CMC 0,5 % 80 Hz to 1000 Hz 0,01 mV/(m·s⁻²) to 10000 mV/(m·s⁻²) CMC 0,75 % 1000 Hz to 5000 Hz 0,01 mV/(m·s⁻²) to 10000 mV/(m·s⁻²) CMC 1,0 % 5000 Hz to 10000 Hz 0,01 mV/(m·s⁻²) to 10000 mV/(m·s⁻²) CMC 2,0 % 5 Hz to 10 Hz 0,01 pC/(m·s⁻²) to 1000 pC/(m·s⁻²) CMC 2,0 % 10 Hz to 20 Hz 0,01 pC/(m·s⁻²) to 1000 pC/(m·s⁻²) CMC 1,0 % 20 Hz to 80 Hz 0,01 pC/(m·s⁻²) to 1000 pC/(m·s⁻²) CMC 0,75 % 80 Hz 0,01 pC/(m·s⁻²) to 1000 pC/(m·s⁻²) CMC 0,5 % 80 Hz to 1000 Hz 0,01 pC/(m·s⁻²) to 1000 pC/(m·s⁻²) CMC 0,75 % 1000 Hz to 5000 Hz 0,01 pC/(m·s⁻²) to 1000 pC/(m·s⁻²) CMC 1,0 % 5000 Hz to 10000 Hz 0,01 pC/(m·s⁻²) to 1000 pC/(m·s⁻²) CMC 2,0 % 5 Hz to 10 Hz 0,01 mV/(m·s⁻¹) to 10000 mV/(m·s⁻¹) CMC 2,0 % 10 Hz to 20 Hz 0,01 mV/(m·s⁻¹) to 10000 mV/(m·s⁻¹) CMC 1,0 % 20 Hz to 80 Hz 0,01 mV/(m·s⁻¹) to 10000 mV/(m·s⁻¹) CMC 0,75 % 80 Hz 0,01 mV/(m·s⁻¹) to 10000 mV/(m·s⁻¹) CMC 0,5 % 80 Hz to 1000 Hz 0,01 mV/(m·s⁻¹) to 10000 mV/(m·s⁻¹) CMC 0,75 % 1000 Hz to 5000 Hz 0,01 mV/(m·s⁻¹) to 10000 mV/(m·s⁻¹) CMC 1,0 % 5000 Hz to 10000 Hz 0,01 mV/(m·s⁻¹) to 10000 mV/(m·s⁻¹) CMC 2,0 % 5 Hz to 10 Hz 0,01 mV/m to 10000 mV/m CMC 2,0 % 10 Hz to 20 Hz 0,01 mV/m to 10000 mV/m CMC 1,0 % 20 Hz to 80 Hz 0,01 mV/m to 10000 mV/m CMC 0,75 % 80 Hz 0,01 mV/m to 10000 mV/m CMC 0,5 % 80 Hz to 1000 Hz 0,01 mV/m to 10000 mV/m CMC 0,75 % 1000 Hz to 5000 Hz 0,01 mV/m to 10000 mV/m CMC 1,0 % 5000 Hz to 10000 Hz 0,01 mV/m to 10000 mV/m CMC 2,0 % I 540 – 068 – 45","search_zh":"振动传感器和测振仪的灵敏度 校准 – 机械运动 与振动标准器比较 5 Hz 至 10 Hz 0,01 mV/(m·s⁻²) 至 10000 mV/(m·s⁻²) CMC 2,0 % 10 Hz 至 20 Hz 0,01 mV/(m·s⁻²) 至 10000 mV/(m·s⁻²) CMC 1,0 % 20 Hz 至 80 Hz 0,01 mV/(m·s⁻²) 至 10000 mV/(m·s⁻²) CMC 0,75 % 80 Hz 0,01 mV/(m·s⁻²) 至 10000 mV/(m·s⁻²) CMC 0,5 % 80 Hz 至 1000 Hz 0,01 mV/(m·s⁻²) 至 10000 mV/(m·s⁻²) CMC 0,75 % 1000 Hz 至 5000 Hz 0,01 mV/(m·s⁻²) 至 10000 mV/(m·s⁻²) CMC 1,0 % 5000 Hz 至 10000 Hz 0,01 mV/(m·s⁻²) 至 10000 mV/(m·s⁻²) CMC 2,0 % 5 Hz 至 10 Hz 0,01 pC/(m·s⁻²) 至 1000 pC/(m·s⁻²) CMC 2,0 % 10 Hz 至 20 Hz 0,01 pC/(m·s⁻²) 至 1000 pC/(m·s⁻²) CMC 1,0 % 20 Hz 至 80 Hz 0,01 pC/(m·s⁻²) 至 1000 pC/(m·s⁻²) CMC 0,75 % 80 Hz 0,01 pC/(m·s⁻²) 至 1000 pC/(m·s⁻²) CMC 0,5 % 80 Hz 至 1000 Hz 0,01 pC/(m·s⁻²) 至 1000 pC/(m·s⁻²) CMC 0,75 % 1000 Hz 至 5000 Hz 0,01 pC/(m·s⁻²) 至 1000 pC/(m·s⁻²) CMC 1,0 % 5000 Hz 至 10000 Hz 0,01 pC/(m·s⁻²) 至 1000 pC/(m·s⁻²) CMC 2,0 % 5 Hz 至 10 Hz 0,01 mV/(m·s⁻¹) 至 10000 mV/(m·s⁻¹) CMC 2,0 % 10 Hz 至 20 Hz 0,01 mV/(m·s⁻¹) 至 10000 mV/(m·s⁻¹) CMC 1,0 % 20 Hz 至 80 Hz 0,01 mV/(m·s⁻¹) 至 10000 mV/(m·s⁻¹) CMC 0,75 % 80 Hz 0,01 mV/(m·s⁻¹) 至 10000 mV/(m·s⁻¹) CMC 0,5 % 80 Hz 至 1000 Hz 0,01 mV/(m·s⁻¹) 至 10000 mV/(m·s⁻¹) CMC 0,75 % 1000 Hz 至 5000 Hz 0,01 mV/(m·s⁻¹) 至 10000 mV/(m·s⁻¹) CMC 1,0 % 5000 Hz 至 10000 Hz 0,01 mV/(m·s⁻¹) 至 10000 mV/(m·s⁻¹) CMC 2,0 % 5 Hz 至 10 Hz 0,01 mV/m 至 10000 mV/m CMC 2,0 % 10 Hz 至 20 Hz 0,01 mV/m 至 10000 mV/m CMC 1,0 % 20 Hz 至 80 Hz 0,01 mV/m 至 10000 mV/m CMC 0,75 % 80 Hz 0,01 mV/m 至 10000 mV/m CMC 0,5 % 80 Hz 至 1000 Hz 0,01 mV/m 至 10000 mV/m CMC 0,75 % 1000 Hz 至 5000 Hz 0,01 mV/m 至 10000 mV/m CMC 1,0 % 5000 Hz 至 10000 Hz 0,01 mV/m 至 10000 mV/m CMC 2,0 % I 540 – 068 – 45","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d2d5dd5f7258f414d17279d6","lab_id":"6ade8b52ff06824761708141","country":"CZ","accr_number":"2405","accr_body":"ČIA","row_label":"4","test_object":"Przenoszenie wzmacniaczy, filtrów i wibrometrów","test_object_en":"Transmission of amplifiers, filters and vibrometers","test_object_zh":"放大器、滤波器和测振仪的传递","test_object_cs":"Přenos zesilovačů, filtrů a vibrometrů","methodology":"Wzorcowanie – ruch mechaniczny","methodology_en":"Calibration – mechanical motion","methodology_zh":"校准 – 机械运动","methodology_cs":"Kalibrace – mechanický pohyb","parameters":[{"name":"0,2 Hz do 1 Hz","range":"od 0,001 mV/pC do 10000 mV/pC","cmc":"0,5 %"},{"name":"1 Hz do 5000 Hz","range":"od 0,001 mV/pC do 10000 mV/pC","cmc":"0,4 %"},{"name":"5000 Hz do 10000 Hz","range":"od 0,001 mV/pC do 10000 mV/pC","cmc":"0,4 %"},{"name":"10000 Hz do 20000 Hz","range":"od 0,001 mV/pC do 10000 mV/pC","cmc":"0,6 %"},{"name":"20000 Hz do 50000 Hz","range":"od 0,001 mV/pC do 10000 mV/pC","cmc":"1,0 %"},{"name":"0,2 Hz do 1 Hz","range":"od 0,001 V/V do 1000 V/V","cmc":"0,4 %"},{"name":"1 Hz do 20000 Hz","range":"od 0,001 V/V do 1000 V/V","cmc":"0,3 %"},{"name":"do 50000 Hz","range":"od 0,001 V/V do 1000 V/V","cmc":"1,0 %"}],"parameters_en":[{"name":"0,2 Hz to 1 Hz","range":"0,001 mV/pC to 10000 mV/pC","cmc":"0,5 %"},{"name":"1 Hz to 5000 Hz","range":"0,001 mV/pC to 10000 mV/pC","cmc":"0,4 %"},{"name":"5000 Hz to 10000 Hz","range":"0,001 mV/pC to 10000 mV/pC","cmc":"0,4 %"},{"name":"10000 Hz to 20000 Hz","range":"0,001 mV/pC to 10000 mV/pC","cmc":"0,6 %"},{"name":"20000 Hz to 50000 Hz","range":"0,001 mV/pC to 10000 mV/pC","cmc":"1,0 %"},{"name":"0,2 Hz to 1 Hz","range":"0,001 V/V to 1000 V/V","cmc":"0,4 %"},{"name":"1 Hz to 20000 Hz","range":"0,001 V/V to 1000 V/V","cmc":"0,3 %"},{"name":"up to 50000 Hz","range":"0,001 V/V to 1000 V/V","cmc":"1,0 %"}],"parameters_zh":[{"name":"0,2 Hz 至 1 Hz","range":"0,001 mV/pC 至 10000 mV/pC","cmc":"0,5 %"},{"name":"1 Hz 至 5000 Hz","range":"0,001 mV/pC 至 10000 mV/pC","cmc":"0,4 %"},{"name":"5000 Hz 至 10000 Hz","range":"0,001 mV/pC 至 10000 mV/pC","cmc":"0,4 %"},{"name":"10000 Hz 至 20000 Hz","range":"0,001 mV/pC 至 10000 mV/pC","cmc":"0,6 %"},{"name":"20000 Hz 至 50000 Hz","range":"0,001 mV/pC 至 10000 mV/pC","cmc":"1,0 %"},{"name":"0,2 Hz 至 1 Hz","range":"0,001 V/V 至 1000 V/V","cmc":"0,4 %"},{"name":"1 Hz 至 20000 Hz","range":"0,001 V/V 至 1000 V/V","cmc":"0,3 %"},{"name":"至 50000 Hz","range":"0,001 V/V 至 1000 V/V","cmc":"1,0 %"}],"parameters_cs":[{"name":"0,2 Hz až 1 Hz","range":"0,001 mV/pC až 10000 mV/pC","cmc":"0,5 %"},{"name":"1 Hz až 5000 Hz","range":"0,001 mV/pC až 10000 mV/pC","cmc":"0,4 %"},{"name":"5000 Hz až 10000 Hz","range":"0,001 mV/pC až 10000 mV/pC","cmc":"0,4 %"},{"name":"10000 Hz až 20000 Hz","range":"0,001 mV/pC až 10000 mV/pC","cmc":"0,6 %"},{"name":"20000 Hz až 50000 Hz","range":"0,001 mV/pC až 10000 mV/pC","cmc":"1,0 %"},{"name":"0,2 Hz až 1 Hz","range":"0,001 V/V až 1000 V/V","cmc":"0,4 %"},{"name":"1 Hz až 20000 Hz","range":"0,001 V/V až 1000 V/V","cmc":"0,3 %"},{"name":"až 50000 Hz","range":"0,001 V/V až 1000 V/V","cmc":"1,0 %"}],"technique":"pomiar bezpośredni","technique_en":"direct measurement","technique_zh":"直接测量","technique_cs":"přímé měření","techniques":["pomiar bezpośredni"],"techniques_en":["direct measurement"],"techniques_zh":["直接测量"],"techniques_cs":["přímé měření"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny\nZakres:\n0,2 Hz do 1 Hz od 0,001 mV/pC do 10000 mV/pC CMC 0,5 %\n1 Hz do 5000 Hz od 0,001 mV/pC do 10000 mV/pC CMC 0,4 %\n5000 Hz do 10000 Hz od 0,001 mV/pC do 10000 mV/pC CMC 0,4 %\n10000 Hz do 20000 Hz od 0,001 mV/pC do 10000 mV/pC CMC 0,6 %\n20000 Hz do 50000 Hz od 0,001 mV/pC do 10000 mV/pC CMC 1,0 %\n0,2 Hz do 1 Hz od 0,001 V/V do 1000 V/V CMC 0,4 %\n1 Hz do 20000 Hz od 0,001 V/V do 1000 V/V CMC 0,3 %\ndo 50000 Hz od 0,001 V/V do 1000 V/V CMC 1,0 %\npomiar bezpośredni","reference":"I 540 – 068 – 45","norm_bases":["I 540 – 068 – 45"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion","regulatory_area_zh":"被测量领域的CMC：机械运动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przenoszenie wzmacniaczy, filtrów i wibrometrów Wzorcowanie – ruch mechaniczny pomiar bezpośredni 0,2 Hz do 1 Hz od 0,001 mV/pC do 10000 mV/pC CMC 0,5 % 1 Hz do 5000 Hz od 0,001 mV/pC do 10000 mV/pC CMC 0,4 % 5000 Hz do 10000 Hz od 0,001 mV/pC do 10000 mV/pC CMC 0,4 % 10000 Hz do 20000 Hz od 0,001 mV/pC do 10000 mV/pC CMC 0,6 % 20000 Hz do 50000 Hz od 0,001 mV/pC do 10000 mV/pC CMC 1,0 % 0,2 Hz do 1 Hz od 0,001 V/V do 1000 V/V CMC 0,4 % 1 Hz do 20000 Hz od 0,001 V/V do 1000 V/V CMC 0,3 % do 50000 Hz od 0,001 V/V do 1000 V/V CMC 1,0 % Přenos zesilovačů, filtrů a vibrometrů Kalibrace – mechanický pohyb přímé měření 0,2 Hz až 1 Hz 0,001 mV/pC až 10000 mV/pC CMC 0,5 % 1 Hz až 5000 Hz 0,001 mV/pC až 10000 mV/pC CMC 0,4 % 5000 Hz až 10000 Hz 0,001 mV/pC až 10000 mV/pC CMC 0,4 % 10000 Hz až 20000 Hz 0,001 mV/pC až 10000 mV/pC CMC 0,6 % 20000 Hz až 50000 Hz 0,001 mV/pC až 10000 mV/pC CMC 1,0 % 0,2 Hz až 1 Hz 0,001 V/V až 1000 V/V CMC 0,4 % 1 Hz až 20000 Hz 0,001 V/V až 1000 V/V CMC 0,3 % až 50000 Hz 0,001 V/V až 1000 V/V CMC 1,0 % I 540 – 068 – 45 Przenoszenie wzmacniaczy, filtrow i wibrometrow Wzorcowanie – ruch mechaniczny pomiar bezposredni 0,2 Hz do 1 Hz od 0,001 mV/pC do 10000 mV/pC CMC 0,5 % 1 Hz do 5000 Hz od 0,001 mV/pC do 10000 mV/pC CMC 0,4 % 5000 Hz do 10000 Hz od 0,001 mV/pC do 10000 mV/pC CMC 0,4 % 10000 Hz do 20000 Hz od 0,001 mV/pC do 10000 mV/pC CMC 0,6 % 20000 Hz do 50000 Hz od 0,001 mV/pC do 10000 mV/pC CMC 1,0 % 0,2 Hz do 1 Hz od 0,001 V/V do 1000 V/V CMC 0,4 % 1 Hz do 20000 Hz od 0,001 V/V do 1000 V/V CMC 0,3 % do 50000 Hz od 0,001 V/V do 1000 V/V CMC 1,0 % Prenos zesilovacu, filtru a vibrometru Kalibrace – mechanicky pohyb prime mereni 0,2 Hz az 1 Hz 0,001 mV/pC az 10000 mV/pC CMC 0,5 % 1 Hz az 5000 Hz 0,001 mV/pC az 10000 mV/pC CMC 0,4 % 5000 Hz az 10000 Hz 0,001 mV/pC az 10000 mV/pC CMC 0,4 % 10000 Hz az 20000 Hz 0,001 mV/pC az 10000 mV/pC CMC 0,6 % 20000 Hz az 50000 Hz 0,001 mV/pC az 10000 mV/pC CMC 1,0 % 0,2 Hz az 1 Hz 0,001 V/V az 1000 V/V CMC 0,4 % 1 Hz az 20000 Hz 0,001 V/V az 1000 V/V CMC 0,3 % az 50000 Hz 0,001 V/V az 1000 V/V CMC 1,0 % I 540 – 068 – 45","search_en":"Transmission of amplifiers, filters and vibrometers Calibration – mechanical motion direct measurement 0,2 Hz to 1 Hz 0,001 mV/pC to 10000 mV/pC CMC 0,5 % 1 Hz to 5000 Hz 0,001 mV/pC to 10000 mV/pC CMC 0,4 % 5000 Hz to 10000 Hz 0,001 mV/pC to 10000 mV/pC CMC 0,4 % 10000 Hz to 20000 Hz 0,001 mV/pC to 10000 mV/pC CMC 0,6 % 20000 Hz to 50000 Hz 0,001 mV/pC to 10000 mV/pC CMC 1,0 % 0,2 Hz to 1 Hz 0,001 V/V to 1000 V/V CMC 0,4 % 1 Hz to 20000 Hz 0,001 V/V to 1000 V/V CMC 0,3 % up to 50000 Hz 0,001 V/V to 1000 V/V CMC 1,0 % I 540 – 068 – 45","search_zh":"放大器、滤波器和测振仪的传递 校准 – 机械运动 直接测量 0,2 Hz 至 1 Hz 0,001 mV/pC 至 10000 mV/pC CMC 0,5 % 1 Hz 至 5000 Hz 0,001 mV/pC 至 10000 mV/pC CMC 0,4 % 5000 Hz 至 10000 Hz 0,001 mV/pC 至 10000 mV/pC CMC 0,4 % 10000 Hz 至 20000 Hz 0,001 mV/pC 至 10000 mV/pC CMC 0,6 % 20000 Hz 至 50000 Hz 0,001 mV/pC 至 10000 mV/pC CMC 1,0 % 0,2 Hz 至 1 Hz 0,001 V/V 至 1000 V/V CMC 0,4 % 1 Hz 至 20000 Hz 0,001 V/V 至 1000 V/V CMC 0,3 % 至 50000 Hz 0,001 V/V 至 1000 V/V CMC 1,0 % I 540 – 068 – 45","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"981a6a854eb85711359262b4","lab_id":"6ade8b52ff06824761708141","country":"CZ","accr_number":"2405","accr_body":"ČIA","row_label":"5","test_object":"Pomiar drgań / Generatory drgań","test_object_en":"Vibration measurement / Vibration generators","test_object_zh":"振动测量 / 振动发生器","test_object_cs":"Měření vibrací / Generátory vibrací","methodology":"Wzorcowanie – ruch mechaniczny","methodology_en":"Calibration – mechanical motion","methodology_zh":"校准 – 机械运动","methodology_cs":"Kalibrace – mechanický pohyb","parameters":[{"name":"5 Hz do 10 Hz","range":"od 0,1 m·s⁻² do 295 m·s⁻²","cmc":"2,0 %"},{"name":"10 Hz do 20 Hz","range":"od 0,1 m·s⁻² do 295 m·s⁻²","cmc":"1,0 %"},{"name":"20 Hz do 80 Hz","range":"od 0,1 m·s⁻² do 295 m·s⁻²","cmc":"0,75 %"},{"name":"80 Hz","range":"od 0,1 m·s⁻² do 295 m·s⁻²","cmc":"0,5 %"},{"name":"80 Hz do 1000 Hz","range":"od 0,1 m·s⁻² do 295 m·s⁻²","cmc":"0,75 %"},{"name":"1000 Hz do 5000 Hz","range":"od 0,1 m·s⁻² do 295 m·s⁻²","cmc":"1,0 %"},{"name":"5000 Hz do 10000 Hz","range":"od 0,1 m·s⁻² do 295 m·s⁻²","cmc":"2,0 %"}],"parameters_en":[{"name":"5 Hz to 10 Hz","range":"0,1 m·s⁻² to 295 m·s⁻²","cmc":"2,0 %"},{"name":"10 Hz to 20 Hz","range":"0,1 m·s⁻² to 295 m·s⁻²","cmc":"1,0 %"},{"name":"20 Hz to 80 Hz","range":"0,1 m·s⁻² to 295 m·s⁻²","cmc":"0,75 %"},{"name":"80 Hz","range":"0,1 m·s⁻² to 295 m·s⁻²","cmc":"0,5 %"},{"name":"80 Hz to 1000 Hz","range":"0,1 m·s⁻² to 295 m·s⁻²","cmc":"0,75 %"},{"name":"1000 Hz to 5000 Hz","range":"0,1 m·s⁻² to 295 m·s⁻²","cmc":"1,0 %"},{"name":"5000 Hz to 10000 Hz","range":"0,1 m·s⁻² to 295 m·s⁻²","cmc":"2,0 %"}],"parameters_zh":[{"name":"5 Hz 至 10 Hz","range":"0,1 m·s⁻² 至 295 m·s⁻²","cmc":"2,0 %"},{"name":"10 Hz 至 20 Hz","range":"0,1 m·s⁻² 至 295 m·s⁻²","cmc":"1,0 %"},{"name":"20 Hz 至 80 Hz","range":"0,1 m·s⁻² 至 295 m·s⁻²","cmc":"0,75 %"},{"name":"80 Hz","range":"0,1 m·s⁻² 至 295 m·s⁻²","cmc":"0,5 %"},{"name":"80 Hz 至 1000 Hz","range":"0,1 m·s⁻² 至 295 m·s⁻²","cmc":"0,75 %"},{"name":"1000 Hz 至 5000 Hz","range":"0,1 m·s⁻² 至 295 m·s⁻²","cmc":"1,0 %"},{"name":"5000 Hz 至 10000 Hz","range":"0,1 m·s⁻² 至 295 m·s⁻²","cmc":"2,0 %"}],"parameters_cs":[{"name":"5 Hz až 10 Hz","range":"0,1 m·s⁻² až 295 m·s⁻²","cmc":"2,0 %"},{"name":"10 Hz až 20 Hz","range":"0,1 m·s⁻² až 295 m·s⁻²","cmc":"1,0 %"},{"name":"20 Hz až 80 Hz","range":"0,1 m·s⁻² až 295 m·s⁻²","cmc":"0,75 %"},{"name":"80 Hz","range":"0,1 m·s⁻² až 295 m·s⁻²","cmc":"0,5 %"},{"name":"80 Hz až 1000 Hz","range":"0,1 m·s⁻² až 295 m·s⁻²","cmc":"0,75 %"},{"name":"1000 Hz až 5000 Hz","range":"0,1 m·s⁻² až 295 m·s⁻²","cmc":"1,0 %"},{"name":"5000 Hz až 10000 Hz","range":"0,1 m·s⁻² až 295 m·s⁻²","cmc":"2,0 %"}],"technique":"pomiar bezpośredni","technique_en":"direct measurement","technique_zh":"直接测量","technique_cs":"přímé měření","techniques":["pomiar bezpośredni"],"techniques_en":["direct measurement"],"techniques_zh":["直接测量"],"techniques_cs":["přímé měření"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny\nZakres:\n5 Hz do 10 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 2,0 %\n10 Hz do 20 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 1,0 %\n20 Hz do 80 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 0,75 %\n80 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 0,5 %\n80 Hz do 1000 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 0,75 %\n1000 Hz do 5000 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 1,0 %\n5000 Hz do 10000 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 2,0 %\npomiar bezpośredni","reference":"I 540 – 068 – 45","norm_bases":["I 540 – 068 – 45"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion","regulatory_area_zh":"被测量领域的CMC：机械运动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wielkością mierzoną mogą być także prędkość, wychylenie, pod warunkiem generowania sygnału drgań o przebiegu harmonicznym o znanej częstotliwości. Można podawać także w jednostkach g, pC/g lub mV/g, przy czym 1 g = 9,807 m·s⁻²","note_en":"The measured quantity can also be velocity and displacement, assuming that a vibrational signal of the harmonic waveform is generated at a known frequency. It can also be given in the units g, pC/g or mV/g, where 1 g = 9.807 m·s⁻²","note_zh":"被测量也可以是速度、位移，前提是以已知频率产生简谐振动信号。也可用 g、pC/g 或 mV/g 表示，其中 1 g = 9,807 m·s⁻²","note_cs":"Měřenou veličinou mohou být i rychlost, výchylka za předpokladu generování vibračního signálu harmonického průběhu na známém kmitočtu. Možno uvádět i v jednotkách g, pC/g, resp. mV/g, přičemž 1 g = 9,807 m·s⁻²","search_text":"Pomiar drgań / Generatory drgań Wzorcowanie – ruch mechaniczny pomiar bezpośredni 5 Hz do 10 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 2,0 % 10 Hz do 20 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 1,0 % 20 Hz do 80 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 0,75 % 80 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 0,5 % 80 Hz do 1000 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 0,75 % 1000 Hz do 5000 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 1,0 % 5000 Hz do 10000 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 2,0 % Měření vibrací / Generátory vibrací Kalibrace – mechanický pohyb přímé měření 5 Hz až 10 Hz 0,1 m·s⁻² až 295 m·s⁻² CMC 2,0 % 10 Hz až 20 Hz 0,1 m·s⁻² až 295 m·s⁻² CMC 1,0 % 20 Hz až 80 Hz 0,1 m·s⁻² až 295 m·s⁻² CMC 0,75 % 80 Hz 0,1 m·s⁻² až 295 m·s⁻² CMC 0,5 % 80 Hz až 1000 Hz 0,1 m·s⁻² až 295 m·s⁻² CMC 0,75 % 1000 Hz až 5000 Hz 0,1 m·s⁻² až 295 m·s⁻² CMC 1,0 % 5000 Hz až 10000 Hz 0,1 m·s⁻² až 295 m·s⁻² CMC 2,0 % I 540 – 068 – 45 Pomiar drgan / Generatory drgan Wzorcowanie – ruch mechaniczny pomiar bezposredni 5 Hz do 10 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 2,0 % 10 Hz do 20 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 1,0 % 20 Hz do 80 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 0,75 % 80 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 0,5 % 80 Hz do 1000 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 0,75 % 1000 Hz do 5000 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 1,0 % 5000 Hz do 10000 Hz od 0,1 m·s⁻² do 295 m·s⁻² CMC 2,0 % Mereni vibraci / Generatory vibraci Kalibrace – mechanicky pohyb prime mereni 5 Hz az 10 Hz 0,1 m·s⁻² az 295 m·s⁻² CMC 2,0 % 10 Hz az 20 Hz 0,1 m·s⁻² az 295 m·s⁻² CMC 1,0 % 20 Hz az 80 Hz 0,1 m·s⁻² az 295 m·s⁻² CMC 0,75 % 80 Hz 0,1 m·s⁻² az 295 m·s⁻² CMC 0,5 % 80 Hz az 1000 Hz 0,1 m·s⁻² az 295 m·s⁻² CMC 0,75 % 1000 Hz az 5000 Hz 0,1 m·s⁻² az 295 m·s⁻² CMC 1,0 % 5000 Hz az 10000 Hz 0,1 m·s⁻² az 295 m·s⁻² CMC 2,0 % I 540 – 068 – 45","search_en":"Vibration measurement / Vibration generators Calibration – mechanical motion direct measurement 5 Hz to 10 Hz 0,1 m·s⁻² to 295 m·s⁻² CMC 2,0 % 10 Hz to 20 Hz 0,1 m·s⁻² to 295 m·s⁻² CMC 1,0 % 20 Hz to 80 Hz 0,1 m·s⁻² to 295 m·s⁻² CMC 0,75 % 80 Hz 0,1 m·s⁻² to 295 m·s⁻² CMC 0,5 % 80 Hz to 1000 Hz 0,1 m·s⁻² to 295 m·s⁻² CMC 0,75 % 1000 Hz to 5000 Hz 0,1 m·s⁻² to 295 m·s⁻² CMC 1,0 % 5000 Hz to 10000 Hz 0,1 m·s⁻² to 295 m·s⁻² CMC 2,0 % I 540 – 068 – 45","search_zh":"振动测量 / 振动发生器 校准 – 机械运动 直接测量 5 Hz 至 10 Hz 0,1 m·s⁻² 至 295 m·s⁻² CMC 2,0 % 10 Hz 至 20 Hz 0,1 m·s⁻² 至 295 m·s⁻² CMC 1,0 % 20 Hz 至 80 Hz 0,1 m·s⁻² 至 295 m·s⁻² CMC 0,75 % 80 Hz 0,1 m·s⁻² 至 295 m·s⁻² CMC 0,5 % 80 Hz 至 1000 Hz 0,1 m·s⁻² 至 295 m·s⁻² CMC 0,75 % 1000 Hz 至 5000 Hz 0,1 m·s⁻² 至 295 m·s⁻² CMC 1,0 % 5000 Hz 至 10000 Hz 0,1 m·s⁻² 至 295 m·s⁻² CMC 2,0 % I 540 – 068 – 45","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"995e1ec55cc9875811e2a479","lab_id":"6ade8b52ff06824761708141","country":"CZ","accr_number":"2405","accr_body":"ČIA","row_label":"6","test_object":"Prędkościomierze, prędkościomierze GPS i radarowe, czujniki prędkości","test_object_en":"Speedometers, GPS and radar speedometers, speed sensors","test_object_zh":"速度表、GPS 和雷达测速仪、速度传感器","test_object_cs":"Rychloměry, GPS a radarové rychloměry, snímače rychlosti","methodology":"Wzorcowanie – ruch mechaniczny","methodology_en":"Calibration – mechanical motion","methodology_zh":"校准 – 机械运动","methodology_cs":"Kalibrace – mechanický pohyb","parameters":[{"name":"droga wzorcowa","range":"od 5 km·h⁻¹ do 180 km·h⁻¹","cmc":"0,02 %"},{"name":"droga wymierzana","range":"od 20 km·h⁻¹ do 130 km·h⁻¹","cmc":"0,04 %"}],"parameters_en":[{"name":"distance standard","range":"5 km·h⁻¹ to 180 km·h⁻¹","cmc":"0,02 %"},{"name":"measured distance","range":"20 km·h⁻¹ to 130 km·h⁻¹","cmc":"0,04 %"}],"parameters_zh":[{"name":"标准距离","range":"5 km·h⁻¹ 至 180 km·h⁻¹","cmc":"0,02 %"},{"name":"测定距离","range":"20 km·h⁻¹ 至 130 km·h⁻¹","cmc":"0,04 %"}],"parameters_cs":[{"name":"etalonová dráha","range":"5 km·h⁻¹ až 180 km·h⁻¹","cmc":"0,02 %"},{"name":"vyměřovaná dráha","range":"20 km·h⁻¹ až 130 km·h⁻¹","cmc":"0,04 %"}],"technique":"porównanie z wzorcem drogi i czasu","technique_en":"comparison with distance and time standard","technique_zh":"与距离和时间标准比较","technique_cs":"porovnání s etalonem dráhy a času","techniques":["porównanie z wzorcem drogi i czasu"],"techniques_en":["comparison with distance and time standard"],"techniques_zh":["与距离和时间标准比较"],"techniques_cs":["porovnání s etalonem dráhy a času"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny\nZakres:\ndroga wzorcowa od 5 km·h⁻¹ do 180 km·h⁻¹ CMC 0,02 %\ndroga wymierzana od 20 km·h⁻¹ do 130 km·h⁻¹ CMC 0,04 %\nporównanie z wzorcem drogi i czasu","reference":"I 540 – 068 – 29","norm_bases":["I 540 – 068 – 29"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion","regulatory_area_zh":"被测量领域的CMC：机械运动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prędkościomierze, prędkościomierze GPS i radarowe, czujniki prędkości Wzorcowanie – ruch mechaniczny porównanie z wzorcem drogi i czasu droga wzorcowa od 5 km·h⁻¹ do 180 km·h⁻¹ CMC 0,02 % droga wymierzana od 20 km·h⁻¹ do 130 km·h⁻¹ CMC 0,04 % Rychloměry, GPS a radarové rychloměry, snímače rychlosti Kalibrace – mechanický pohyb porovnání s etalonem dráhy a času etalonová dráha 5 km·h⁻¹ až 180 km·h⁻¹ CMC 0,02 % vyměřovaná dráha 20 km·h⁻¹ až 130 km·h⁻¹ CMC 0,04 % I 540 – 068 – 29 Predkosciomierze, predkosciomierze GPS i radarowe, czujniki predkosci Wzorcowanie – ruch mechaniczny porownanie z wzorcem drogi i czasu droga wzorcowa od 5 km·h⁻¹ do 180 km·h⁻¹ CMC 0,02 % droga wymierzana od 20 km·h⁻¹ do 130 km·h⁻¹ CMC 0,04 % Rychlomery, GPS a radarove rychlomery, snimace rychlosti Kalibrace – mechanicky pohyb porovnani s etalonem drahy a casu etalonova draha 5 km·h⁻¹ az 180 km·h⁻¹ CMC 0,02 % vymerovana draha 20 km·h⁻¹ az 130 km·h⁻¹ CMC 0,04 % I 540 – 068 – 29","search_en":"Speedometers, GPS and radar speedometers, speed sensors Calibration – mechanical motion comparison with distance and time standard distance standard 5 km·h⁻¹ to 180 km·h⁻¹ CMC 0,02 % measured distance 20 km·h⁻¹ to 130 km·h⁻¹ CMC 0,04 % I 540 – 068 – 29","search_zh":"速度表、GPS 和雷达测速仪、速度传感器 校准 – 机械运动 与距离和时间标准比较 标准距离 5 km·h⁻¹ 至 180 km·h⁻¹ CMC 0,02 % 测定距离 20 km·h⁻¹ 至 130 km·h⁻¹ CMC 0,04 % I 540 – 068 – 29","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"797abce7a10a290b4d82f908","lab_id":"6ade8b52ff06824761708141","country":"CZ","accr_number":"2405","accr_body":"ČIA","row_label":"7","test_object":"Prędkościomierze z kółkiem tocznym","test_object_en":"Speedometers with a rolling wheel","test_object_zh":"带滚轮的速度表","test_object_cs":"Rychloměry s odvalovacím kolečkem","methodology":"Wzorcowanie – ruch mechaniczny","methodology_en":"Calibration – mechanical motion","methodology_zh":"校准 – 机械运动","methodology_cs":"Kalibrace – mechanický pohyb","parameters":[{"name":"","range":"od 2 m·min⁻¹ do 100 m·min⁻¹","cmc":"0,1 % + 0,01 m·min⁻¹"}],"parameters_en":[{"name":"","range":"2 m·min⁻¹ to 100 m·min⁻¹","cmc":"0,1 % + 0,01 m·min⁻¹"}],"parameters_zh":[{"name":"","range":"2 m·min⁻¹ 至 100 m·min⁻¹","cmc":"0,1 % + 0,01 m·min⁻¹"}],"parameters_cs":[{"name":"","range":"2 m·min⁻¹ až 100 m·min⁻¹","cmc":"0,1 % + 0,01 m·min⁻¹"}],"technique":"bezpośrednie generowanie prędkości obwodowej","technique_en":"direct generation of circumferential velocity","technique_zh":"直接产生圆周速度","technique_cs":"přímé generování obvodové rychlosti","techniques":["bezpośrednie generowanie prędkości obwodowej"],"techniques_en":["direct generation of circumferential velocity"],"techniques_zh":["直接产生圆周速度"],"techniques_cs":["přímé generování obvodové rychlosti"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny\nod 2 m·min⁻¹ do 100 m·min⁻¹ CMC 0,1 % + 0,01 m·min⁻¹\nbezpośrednie generowanie prędkości obwodowej","reference":"I 540 – 068 – 05","norm_bases":["I 540 – 068 – 05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion","regulatory_area_zh":"被测量领域的CMC：机械运动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prędkościomierze z kółkiem tocznym Wzorcowanie – ruch mechaniczny bezpośrednie generowanie prędkości obwodowej od 2 m·min⁻¹ do 100 m·min⁻¹ CMC 0,1 % + 0,01 m·min⁻¹ Rychloměry s odvalovacím kolečkem Kalibrace – mechanický pohyb přímé generování obvodové rychlosti 2 m·min⁻¹ až 100 m·min⁻¹ CMC 0,1 % + 0,01 m·min⁻¹ I 540 – 068 – 05 Predkosciomierze z kolkiem tocznym Wzorcowanie – ruch mechaniczny bezposrednie generowanie predkosci obwodowej od 2 m·min⁻¹ do 100 m·min⁻¹ CMC 0,1 % + 0,01 m·min⁻¹ Rychlomery s odvalovacim koleckem Kalibrace – mechanicky pohyb prime generovani obvodove rychlosti 2 m·min⁻¹ az 100 m·min⁻¹ CMC 0,1 % + 0,01 m·min⁻¹ I 540 – 068 – 05","search_en":"Speedometers with a rolling wheel Calibration – mechanical motion direct generation of circumferential velocity 2 m·min⁻¹ to 100 m·min⁻¹ CMC 0,1 % + 0,01 m·min⁻¹ I 540 – 068 – 05","search_zh":"带滚轮的速度表 校准 – 机械运动 直接产生圆周速度 2 m·min⁻¹ 至 100 m·min⁻¹ CMC 0,1 % + 0,01 m·min⁻¹ I 540 – 068 – 05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5f3c7fe027db35458fa820b1","lab_id":"6ade8b52ff06824761708141","country":"CZ","accr_number":"2405","accr_body":"ČIA","row_label":"8","test_object":"Obrotomierze, czujniki prędkości obrotowej, stroboskopy","test_object_en":"Revolution counters, rpm sensors, stroboscopes","test_object_zh":"转速表、转速传感器、频闪仪","test_object_cs":"Otáčkoměry, snímače otáček, stroboskopy","methodology":"Wzorcowanie – ruch mechaniczny","methodology_en":"Calibration – mechanical motion","methodology_zh":"校准 – 机械运动","methodology_cs":"Kalibrace – mechanický pohyb","parameters":[{"name":"","range":"od 500 min⁻¹ do 10 000 min⁻¹","cmc":"0,006 min⁻¹"},{"name":"","range":"od 10 000 min⁻¹ do 100 000 min⁻¹","cmc":"0,06 min⁻¹"}],"parameters_en":[{"name":"","range":"500 min⁻¹ to 10 000 min⁻¹","cmc":"0,006 min⁻¹"},{"name":"","range":"10 000 min⁻¹ to 100 000 min⁻¹","cmc":"0,06 min⁻¹"}],"parameters_zh":[{"name":"","range":"500 min⁻¹ 至 10 000 min⁻¹","cmc":"0,006 min⁻¹"},{"name":"","range":"10 000 min⁻¹ 至 100 000 min⁻¹","cmc":"0,06 min⁻¹"}],"parameters_cs":[{"name":"","range":"500 min⁻¹ až 10 000 min⁻¹","cmc":"0,006 min⁻¹"},{"name":"","range":"10 000 min⁻¹ až 100 000 min⁻¹","cmc":"0,06 min⁻¹"}],"technique":"pomiar bezpośredni sygnału optycznego lub elektrycznego","technique_en":"direct measurement of an optical or electrical signal","technique_zh":"直接测量光信号或电信号","technique_cs":"přímé měření optického nebo elektrického signálu","techniques":["pomiar bezpośredni sygnału optycznego lub elektrycznego"],"techniques_en":["direct measurement of an optical or electrical signal"],"techniques_zh":["直接测量光信号或电信号"],"techniques_cs":["přímé měření optického nebo elektrického signálu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny\nZakres:\nod 500 min⁻¹ do 10 000 min⁻¹ CMC 0,006 min⁻¹\nod 10 000 min⁻¹ do 100 000 min⁻¹ CMC 0,06 min⁻¹\npomiar bezpośredni sygnału optycznego lub elektrycznego","reference":"I 540 – 068 – 05","norm_bases":["I 540 – 068 – 05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion","regulatory_area_zh":"被测量领域的CMC：机械运动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obrotomierze, czujniki prędkości obrotowej, stroboskopy Wzorcowanie – ruch mechaniczny pomiar bezpośredni sygnału optycznego lub elektrycznego od 500 min⁻¹ do 10 000 min⁻¹ CMC 0,006 min⁻¹ od 10 000 min⁻¹ do 100 000 min⁻¹ CMC 0,06 min⁻¹ Otáčkoměry, snímače otáček, stroboskopy Kalibrace – mechanický pohyb přímé měření optického nebo elektrického signálu 500 min⁻¹ až 10 000 min⁻¹ CMC 0,006 min⁻¹ 10 000 min⁻¹ až 100 000 min⁻¹ CMC 0,06 min⁻¹ I 540 – 068 – 05 Obrotomierze, czujniki predkosci obrotowej, stroboskopy Wzorcowanie – ruch mechaniczny pomiar bezposredni sygnalu optycznego lub elektrycznego od 500 min⁻¹ do 10 000 min⁻¹ CMC 0,006 min⁻¹ od 10 000 min⁻¹ do 100 000 min⁻¹ CMC 0,06 min⁻¹ Otackomery, snimace otacek, stroboskopy Kalibrace – mechanicky pohyb prime mereni optickeho nebo elektrickeho signalu 500 min⁻¹ az 10 000 min⁻¹ CMC 0,006 min⁻¹ 10 000 min⁻¹ az 100 000 min⁻¹ CMC 0,06 min⁻¹ I 540 – 068 – 05","search_en":"Revolution counters, rpm sensors, stroboscopes Calibration – mechanical motion direct measurement of an optical or electrical signal 500 min⁻¹ to 10 000 min⁻¹ CMC 0,006 min⁻¹ 10 000 min⁻¹ to 100 000 min⁻¹ CMC 0,06 min⁻¹ I 540 – 068 – 05","search_zh":"转速表、转速传感器、频闪仪 校准 – 机械运动 直接测量光信号或电信号 500 min⁻¹ 至 10 000 min⁻¹ CMC 0,006 min⁻¹ 10 000 min⁻¹ 至 100 000 min⁻¹ CMC 0,06 min⁻¹ I 540 – 068 – 05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6e2ce1d0dad796fd251e9d1c","lab_id":"6ade8b52ff06824761708141","country":"CZ","accr_number":"2405","accr_body":"ČIA","row_label":"9","test_object":"Prędkość kątowa drgań obrotowych o przebiegu harmonicznym / Czujniki prędkości kątowej","test_object_en":"Angular velocity of the vibration-rotation harmonic waveform / Angular velocity sensors","test_object_zh":"简谐振动-旋转角速度 / 角速度传感器","test_object_cs":"Úhlová rychlost vibračně-rotačního harmonického průběhu / Snímače úhlové rychlosti","methodology":"Wzorcowanie – ruch mechaniczny","methodology_en":"Calibration – mechanical motion","methodology_zh":"校准 – 机械运动","methodology_cs":"Kalibrace – mechanický pohyb","parameters":[{"name":"1 Hz do 200 Hz","range":"od 0,01 rad·s⁻¹ do 87,3 rad·s⁻¹","cmc":"1,5 %"}],"parameters_en":[{"name":"1 Hz to 200 Hz","range":"0,01 rad·s⁻¹ to 87,3 rad·s⁻¹","cmc":"1,5 %"}],"parameters_zh":[{"name":"1 Hz 至 200 Hz","range":"0,01 rad·s⁻¹ 至 87,3 rad·s⁻¹","cmc":"1,5 %"}],"parameters_cs":[{"name":"1 Hz až 200 Hz","range":"0,01 rad·s⁻¹ až 87,3 rad·s⁻¹","cmc":"1,5 %"}],"technique":"porównanie z wzorcowym czujnikiem prędkości kątowej","technique_en":"comparison with a standard angular velocity sensor","technique_zh":"与标准角速度传感器比较","technique_cs":"porovnání s etalonovým snímačem úhlové rychlosti","techniques":["porównanie z wzorcowym czujnikiem prędkości kątowej"],"techniques_en":["comparison with a standard angular velocity sensor"],"techniques_zh":["与标准角速度传感器比较"],"techniques_cs":["porovnání s etalonovým snímačem úhlové rychlosti"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny\n1 Hz do 200 Hz od 0,01 rad·s⁻¹ do 87,3 rad·s⁻¹ CMC 1,5 %\nporównanie z wzorcowym czujnikiem prędkości kątowej","reference":"I 540 – 068 – 45","norm_bases":["I 540 – 068 – 45"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion","regulatory_area_zh":"被测量领域的CMC：机械运动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wielkością mierzoną mogą być także przyspieszenie kątowe, wychylenie kątowe, pod warunkiem generowania sygnału drgań obrotowych o przebiegu harmonicznym o znanej częstotliwości. Można podawać także w jednostkach °·s⁻¹, mV/(°·s⁻¹), przy czym 1 °·s⁻¹ = π/180 rad·s⁻¹","note_en":"The measured quantity can also be angular acceleration, angular displacement assuming that a vibration-rotation signal of the harmonic waveform is generated at a known frequency. Can also be given in units of °·s⁻¹, mV/(°·s⁻¹), where 1 °·s⁻¹ = π/180 rad·s⁻¹","note_zh":"被测量也可以是角加速度、角位移，前提是以已知频率产生简谐振动-旋转信号。也可用 °·s⁻¹、mV/(°·s⁻¹) 表示，其中 1 °·s⁻¹ = π/180 rad·s⁻¹","note_cs":"Měřenou veličinou mohou být i úhlové zrychlení, úhlová výchylka za předpokladu generování vibračně-rotačního signálu harmonického průběhu na známém kmitočtu. Možno uvádět i v jednotkách °·s⁻¹, mV/(°·s⁻¹), přičemž 1 °·s⁻¹ = π/180 rad·s⁻¹","search_text":"Prędkość kątowa drgań obrotowych o przebiegu harmonicznym / Czujniki prędkości kątowej Wzorcowanie – ruch mechaniczny porównanie z wzorcowym czujnikiem prędkości kątowej 1 Hz do 200 Hz od 0,01 rad·s⁻¹ do 87,3 rad·s⁻¹ CMC 1,5 % Úhlová rychlost vibračně-rotačního harmonického průběhu / Snímače úhlové rychlosti Kalibrace – mechanický pohyb porovnání s etalonovým snímačem úhlové rychlosti 1 Hz až 200 Hz 0,01 rad·s⁻¹ až 87,3 rad·s⁻¹ CMC 1,5 % I 540 – 068 – 45 Predkosc katowa drgan obrotowych o przebiegu harmonicznym / Czujniki predkosci katowej Wzorcowanie – ruch mechaniczny porownanie z wzorcowym czujnikiem predkosci katowej 1 Hz do 200 Hz od 0,01 rad·s⁻¹ do 87,3 rad·s⁻¹ CMC 1,5 % Uhlova rychlost vibracne-rotacniho harmonickeho prubehu / Snimace uhlove rychlosti Kalibrace – mechanicky pohyb porovnani s etalonovym snimacem uhlove rychlosti 1 Hz az 200 Hz 0,01 rad·s⁻¹ az 87,3 rad·s⁻¹ CMC 1,5 % I 540 – 068 – 45","search_en":"Angular velocity of the vibration-rotation harmonic waveform / Angular velocity sensors Calibration – mechanical motion comparison with a standard angular velocity sensor 1 Hz to 200 Hz 0,01 rad·s⁻¹ to 87,3 rad·s⁻¹ CMC 1,5 % I 540 – 068 – 45","search_zh":"简谐振动-旋转角速度 / 角速度传感器 校准 – 机械运动 与标准角速度传感器比较 1 Hz 至 200 Hz 0,01 rad·s⁻¹ 至 87,3 rad·s⁻¹ CMC 1,5 % I 540 – 068 – 45","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dd7ef36df3c64e733e45efff","lab_id":"6ade8b52ff06824761708141","country":"CZ","accr_number":"2405","accr_body":"ČIA","row_label":"10","test_object":"Czułość czujników prędkości kątowej","test_object_en":"Sensitivity of angular velocity sensors","test_object_zh":"角速度传感器的灵敏度","test_object_cs":"Citlivost snímačů úhlové rychlosti","methodology":"Wzorcowanie – ruch mechaniczny","methodology_en":"Calibration – mechanical motion","methodology_zh":"校准 – 机械运动","methodology_cs":"Kalibrace – mechanický pohyb","parameters":[{"name":"1 Hz do 200 Hz","range":"od 0,001 mV/(rad·s⁻¹) do 10000 mV/(rad·s⁻¹)","cmc":"1,5 %"}],"parameters_en":[{"name":"1 Hz to 200 Hz","range":"0,001 mV/(rad·s⁻¹) to 10000 mV/(rad·s⁻¹)","cmc":"1,5 %"}],"parameters_zh":[{"name":"1 Hz 至 200 Hz","range":"0,001 mV/(rad·s⁻¹) 至 10000 mV/(rad·s⁻¹)","cmc":"1,5 %"}],"parameters_cs":[{"name":"1 Hz až 200 Hz","range":"0,001 mV/(rad·s⁻¹) až 10000 mV/(rad·s⁻¹)","cmc":"1,5 %"}],"technique":"porównanie z wzorcowym czujnikiem prędkości kątowej","technique_en":"comparison with a standard angular velocity sensor","technique_zh":"与标准角速度传感器比较","technique_cs":"porovnání s etalonovým snímačem úhlové rychlosti","techniques":["porównanie z wzorcowym czujnikiem prędkości kątowej"],"techniques_en":["comparison with a standard angular velocity sensor"],"techniques_zh":["与标准角速度传感器比较"],"techniques_cs":["porovnání s etalonovým snímačem úhlové rychlosti"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny\n1 Hz do 200 Hz od 0,001 mV/(rad·s⁻¹) do 10000 mV/(rad·s⁻¹) CMC 1,5 %\nporównanie z wzorcowym czujnikiem prędkości kątowej","reference":"I 540 – 068 – 45","norm_bases":["I 540 – 068 – 45"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion","regulatory_area_zh":"被测量领域的CMC：机械运动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wielkością mierzoną mogą być także przyspieszenie kątowe, wychylenie kątowe, pod warunkiem generowania sygnału drgań obrotowych o przebiegu harmonicznym o znanej częstotliwości. Można podawać także w jednostkach °·s⁻¹, mV/(°·s⁻¹), przy czym 1 °·s⁻¹ = π/180 rad·s⁻¹","note_en":"The measured quantity can also be angular acceleration, angular displacement assuming that a vibration-rotation signal of the harmonic waveform is generated at a known frequency. Can also be given in units of °·s⁻¹, mV/(°·s⁻¹), where 1 °·s⁻¹ = π/180 rad·s⁻¹","note_zh":"被测量也可以是角加速度、角位移，前提是以已知频率产生简谐振动-旋转信号。也可用 °·s⁻¹、mV/(°·s⁻¹) 表示，其中 1 °·s⁻¹ = π/180 rad·s⁻¹","note_cs":"Měřenou veličinou mohou být i úhlové zrychlení, úhlová výchylka za předpokladu generování vibračně-rotačního signálu harmonického průběhu na známém kmitočtu. Možno uvádět i v jednotkách °·s⁻¹, mV/(°·s⁻¹), přičemž 1 °·s⁻¹ = π/180 rad·s⁻¹","search_text":"Czułość czujników prędkości kątowej Wzorcowanie – ruch mechaniczny porównanie z wzorcowym czujnikiem prędkości kątowej 1 Hz do 200 Hz od 0,001 mV/(rad·s⁻¹) do 10000 mV/(rad·s⁻¹) CMC 1,5 % Citlivost snímačů úhlové rychlosti Kalibrace – mechanický pohyb porovnání s etalonovým snímačem úhlové rychlosti 1 Hz až 200 Hz 0,001 mV/(rad·s⁻¹) až 10000 mV/(rad·s⁻¹) CMC 1,5 % I 540 – 068 – 45 Czulosc czujnikow predkosci katowej Wzorcowanie – ruch mechaniczny porownanie z wzorcowym czujnikiem predkosci katowej 1 Hz do 200 Hz od 0,001 mV/(rad·s⁻¹) do 10000 mV/(rad·s⁻¹) CMC 1,5 % Citlivost snimacu uhlove rychlosti Kalibrace – mechanicky pohyb porovnani s etalonovym snimacem uhlove rychlosti 1 Hz az 200 Hz 0,001 mV/(rad·s⁻¹) az 10000 mV/(rad·s⁻¹) CMC 1,5 % I 540 – 068 – 45","search_en":"Sensitivity of angular velocity sensors Calibration – mechanical motion comparison with a standard angular velocity sensor 1 Hz to 200 Hz 0,001 mV/(rad·s⁻¹) to 10000 mV/(rad·s⁻¹) CMC 1,5 % I 540 – 068 – 45","search_zh":"角速度传感器的灵敏度 校准 – 机械运动 与标准角速度传感器比较 1 Hz 至 200 Hz 0,001 mV/(rad·s⁻¹) 至 10000 mV/(rad·s⁻¹) CMC 1,5 % I 540 – 068 – 45","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d005681594f0ed416e8b38e5","lab_id":"6ade8b52ff06824761708141","country":"CZ","accr_number":"2405","accr_body":"ČIA","row_label":"1","test_object":"Ciśnieniomierze sprężyste i elektromechaniczne","test_object_en":"Mechanical and electromechanical manometers","test_object_zh":"弹性式和机电式压力表","test_object_cs":"Deformační a elektromechanické tlakoměry","methodology":"Wzorcowanie – ciśnienie, naprężenie mechaniczne","methodology_en":"Calibration – pressure, mechanical stress","methodology_zh":"校准 – 压力、机械应力","methodology_cs":"Kalibrace – tlak, mechanické napětí","parameters":[{"name":"gaz","range":"od -95 kPa do 0 kPa","cmc":"0,1 kPa"},{"name":"gaz / ciecz","range":"od 0 MPa do 0,7 MPa","cmc":"0,03 % + 0,08 kPa"},{"name":"gaz / ciecz","range":"od 0,7 MPa do 3,5 MPa","cmc":"0,03 % + 0,4 kPa"},{"name":"gaz / ciecz","range":"od 3,5 MPa do 7 MPa","cmc":"0,03 % + 0,8 kPa"},{"name":"gaz / ciecz","range":"od 7 MPa do 20 MPa","cmc":"0,03 % + 2,3 kPa"}],"parameters_en":[{"name":"gas","range":"-95 kPa to 0 kPa","cmc":"0,1 kPa"},{"name":"gas / liquid","range":"0 MPa to 0,7 MPa","cmc":"0,03 % + 0,08 kPa"},{"name":"gas / liquid","range":"0,7 MPa to 3,5 MPa","cmc":"0,03 % + 0,4 kPa"},{"name":"gas / liquid","range":"3,5 MPa to 7 MPa","cmc":"0,03 % + 0,8 kPa"},{"name":"gas / liquid","range":"7 MPa to 20 MPa","cmc":"0,03 % + 2,3 kPa"}],"parameters_zh":[{"name":"气体","range":"-95 kPa 至 0 kPa","cmc":"0,1 kPa"},{"name":"气体 / 液体","range":"0 MPa 至 0,7 MPa","cmc":"0,03 % + 0,08 kPa"},{"name":"气体 / 液体","range":"0,7 MPa 至 3,5 MPa","cmc":"0,03 % + 0,4 kPa"},{"name":"气体 / 液体","range":"3,5 MPa 至 7 MPa","cmc":"0,03 % + 0,8 kPa"},{"name":"气体 / 液体","range":"7 MPa 至 20 MPa","cmc":"0,03 % + 2,3 kPa"}],"parameters_cs":[{"name":"plyn","range":"-95 kPa až 0 kPa","cmc":"0,1 kPa"},{"name":"plyn / kapalina","range":"0 MPa až 0,7 MPa","cmc":"0,03 % + 0,08 kPa"},{"name":"plyn / kapalina","range":"0,7 MPa až 3,5 MPa","cmc":"0,03 % + 0,4 kPa"},{"name":"plyn / kapalina","range":"3,5 MPa až 7 MPa","cmc":"0,03 % + 0,8 kPa"},{"name":"plyn / kapalina","range":"7 MPa až 20 MPa","cmc":"0,03 % + 2,3 kPa"}],"technique":"porównanie z ciśnieniomierzem cyfrowym","technique_en":"comparison with a digital pressure gauge","technique_zh":"与数字压力表比较","technique_cs":"porovnání s digitálním tlakoměrem","techniques":["porównanie z ciśnieniomierzem cyfrowym"],"techniques_en":["comparison with a digital pressure gauge"],"techniques_zh":["与数字压力表比较"],"techniques_cs":["porovnání s digitálním tlakoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie, naprężenie mechaniczne\nZakres:\ngaz od -95 kPa do 0 kPa CMC 0,1 kPa\ngaz / ciecz od 0 MPa do 0,7 MPa CMC 0,03 % + 0,08 kPa\ngaz / ciecz od 0,7 MPa do 3,5 MPa CMC 0,03 % + 0,4 kPa\ngaz / ciecz od 3,5 MPa do 7 MPa CMC 0,03 % + 0,8 kPa\ngaz / ciecz od 7 MPa do 20 MPa CMC 0,03 % + 2,3 kPa\nporównanie z ciśnieniomierzem cyfrowym","reference":"I540 – 068 – 3","norm_bases":["I540 – 068 – 3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie, naprężenie mechaniczne","regulatory_area_en":"CMC for the field of measured quantity: Pressure, mechanical stress","regulatory_area_zh":"被测量领域的CMC：压力、机械应力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak, mechanické napětí","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ciśnieniomierze sprężyste i elektromechaniczne Wzorcowanie – ciśnienie, naprężenie mechaniczne porównanie z ciśnieniomierzem cyfrowym gaz od -95 kPa do 0 kPa CMC 0,1 kPa gaz / ciecz od 0 MPa do 0,7 MPa CMC 0,03 % + 0,08 kPa gaz / ciecz od 0,7 MPa do 3,5 MPa CMC 0,03 % + 0,4 kPa gaz / ciecz od 3,5 MPa do 7 MPa CMC 0,03 % + 0,8 kPa gaz / ciecz od 7 MPa do 20 MPa CMC 0,03 % + 2,3 kPa Deformační a elektromechanické tlakoměry Kalibrace – tlak, mechanické napětí porovnání s digitálním tlakoměrem plyn -95 kPa až 0 kPa CMC 0,1 kPa plyn / kapalina 0 MPa až 0,7 MPa CMC 0,03 % + 0,08 kPa plyn / kapalina 0,7 MPa až 3,5 MPa CMC 0,03 % + 0,4 kPa plyn / kapalina 3,5 MPa až 7 MPa CMC 0,03 % + 0,8 kPa plyn / kapalina 7 MPa až 20 MPa CMC 0,03 % + 2,3 kPa I540 – 068 – 3 Cisnieniomierze sprezyste i elektromechaniczne Wzorcowanie – cisnienie, naprezenie mechaniczne porownanie z cisnieniomierzem cyfrowym gaz od -95 kPa do 0 kPa CMC 0,1 kPa gaz / ciecz od 0 MPa do 0,7 MPa CMC 0,03 % + 0,08 kPa gaz / ciecz od 0,7 MPa do 3,5 MPa CMC 0,03 % + 0,4 kPa gaz / ciecz od 3,5 MPa do 7 MPa CMC 0,03 % + 0,8 kPa gaz / ciecz od 7 MPa do 20 MPa CMC 0,03 % + 2,3 kPa Deformacni a elektromechanicke tlakomery Kalibrace – tlak, mechanicke napeti porovnani s digitalnim tlakomerem plyn -95 kPa az 0 kPa CMC 0,1 kPa plyn / kapalina 0 MPa az 0,7 MPa CMC 0,03 % + 0,08 kPa plyn / kapalina 0,7 MPa az 3,5 MPa CMC 0,03 % + 0,4 kPa plyn / kapalina 3,5 MPa az 7 MPa CMC 0,03 % + 0,8 kPa plyn / kapalina 7 MPa az 20 MPa CMC 0,03 % + 2,3 kPa I540 – 068 – 3","search_en":"Mechanical and electromechanical manometers Calibration – pressure, mechanical stress comparison with a digital pressure gauge gas -95 kPa to 0 kPa CMC 0,1 kPa gas / liquid 0 MPa to 0,7 MPa CMC 0,03 % + 0,08 kPa gas / liquid 0,7 MPa to 3,5 MPa CMC 0,03 % + 0,4 kPa gas / liquid 3,5 MPa to 7 MPa CMC 0,03 % + 0,8 kPa gas / liquid 7 MPa to 20 MPa CMC 0,03 % + 2,3 kPa I540 – 068 – 3","search_zh":"弹性式和机电式压力表 校准 – 压力、机械应力 与数字压力表比较 气体 -95 kPa 至 0 kPa CMC 0,1 kPa 气体 / 液体 0 MPa 至 0,7 MPa CMC 0,03 % + 0,08 kPa 气体 / 液体 0,7 MPa 至 3,5 MPa CMC 0,03 % + 0,4 kPa 气体 / 液体 3,5 MPa 至 7 MPa CMC 0,03 % + 0,8 kPa 气体 / 液体 7 MPa 至 20 MPa CMC 0,03 % + 2,3 kPa I540 – 068 – 3","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f893dcfc0d9a81d5009b6cb3","lab_id":"6ade8b52ff06824761708141","country":"CZ","accr_number":"2405","accr_body":"ČIA","row_label":"1","test_object":"Ciśnieniomierze sprężyste i elektromechaniczne","test_object_en":"Mechanical and electromechanical manometers","test_object_zh":"弹性式和机电式压力表","test_object_cs":"Deformační a elektromechanické tlakoměry","methodology":"Wzorcowanie – ciśnienie, naprężenie mechaniczne","methodology_en":"Calibration – pressure, mechanical stress","methodology_zh":"校准 – 压力、机械应力","methodology_cs":"Kalibrace – tlak, mechanické napětí","parameters":[{"name":"olej","range":"od 0 MPa do 6 MPa","cmc":"3,5 kPa"},{"name":"olej","range":"od 6 MPa do 60 MPa","cmc":"0,06 %"}],"parameters_en":[{"name":"oil","range":"0 MPa to 6 MPa","cmc":"3,5 kPa"},{"name":"oil","range":"6 MPa to 60 MPa","cmc":"0,06 %"}],"parameters_zh":[{"name":"油","range":"0 MPa 至 6 MPa","cmc":"3,5 kPa"},{"name":"油","range":"6 MPa 至 60 MPa","cmc":"0,06 %"}],"parameters_cs":[{"name":"olej","range":"0 MPa až 6 MPa","cmc":"3,5 kPa"},{"name":"olej","range":"6 MPa až 60 MPa","cmc":"0,06 %"}],"technique":"porównanie z ciśnieniomierzem tłokowym","technique_en":"comparison with a piston pressure gauge","technique_zh":"与活塞式压力计比较","technique_cs":"porovnání s pístovým tlakoměrem","techniques":["porównanie z ciśnieniomierzem tłokowym"],"techniques_en":["comparison with a piston pressure gauge"],"techniques_zh":["与活塞式压力计比较"],"techniques_cs":["porovnání s pístovým tlakoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie, naprężenie mechaniczne\nZakres:\nolej od 0 MPa do 6 MPa CMC 3,5 kPa\nolej od 6 MPa do 60 MPa CMC 0,06 %\nporównanie z ciśnieniomierzem tłokowym","reference":"I540 – 068 – 3","norm_bases":["I540 – 068 – 3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie, naprężenie mechaniczne","regulatory_area_en":"CMC for the field of measured quantity: Pressure, mechanical stress","regulatory_area_zh":"被测量领域的CMC：压力、机械应力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak, mechanické napětí","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ciśnieniomierze sprężyste i elektromechaniczne Wzorcowanie – ciśnienie, naprężenie mechaniczne porównanie z ciśnieniomierzem tłokowym olej od 0 MPa do 6 MPa CMC 3,5 kPa olej od 6 MPa do 60 MPa CMC 0,06 % Deformační a elektromechanické tlakoměry Kalibrace – tlak, mechanické napětí porovnání s pístovým tlakoměrem olej 0 MPa až 6 MPa CMC 3,5 kPa olej 6 MPa až 60 MPa CMC 0,06 % I540 – 068 – 3 Cisnieniomierze sprezyste i elektromechaniczne Wzorcowanie – cisnienie, naprezenie mechaniczne porownanie z cisnieniomierzem tlokowym olej od 0 MPa do 6 MPa CMC 3,5 kPa olej od 6 MPa do 60 MPa CMC 0,06 % Deformacni a elektromechanicke tlakomery Kalibrace – tlak, mechanicke napeti porovnani s pistovym tlakomerem olej 0 MPa az 6 MPa CMC 3,5 kPa olej 6 MPa az 60 MPa CMC 0,06 % I540 – 068 – 3","search_en":"Mechanical and electromechanical manometers Calibration – pressure, mechanical stress comparison with a piston pressure gauge oil 0 MPa to 6 MPa CMC 3,5 kPa oil 6 MPa to 60 MPa CMC 0,06 % I540 – 068 – 3","search_zh":"弹性式和机电式压力表 校准 – 压力、机械应力 与活塞式压力计比较 油 0 MPa 至 6 MPa CMC 3,5 kPa 油 6 MPa 至 60 MPa CMC 0,06 % I540 – 068 – 3","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6803a2b9436d83e1c740aa08","lab_id":"6ade8b52ff06824761708141","country":"CZ","accr_number":"2405","accr_body":"ČIA","row_label":"1","test_object":"Pomiar częstotliwości, generatory częstotliwości, cyfrowe kamery szybkie, skrzynki synchronizacyjne, podstawy czasu przyrządów i systemów pomiarowych, liczniki i mierniki częstotliwości","test_object_en":"Frequency measurement, frequency generators, digital speed cameras, synchronization boxes, time bases for measuring instruments and systems, counters and frequency meters","test_object_zh":"频率测量、频率发生器、数字高速摄像机、同步盒、测量仪器和系统的时基、计数器和频率计","test_object_cs":"Měření frekvence, frekvenční generátory, digitální rychlokamery, synchronizační boxy, časové základny měřicích přístrojů a systémů, čítače a měřiče frekvence","methodology":"Wzorcowanie – czas, częstotliwość","methodology_en":"Calibration – time, frequency","methodology_zh":"校准 – 时间、频率","methodology_cs":"Kalibrace – čas, frekvence","parameters":[{"name":"","range":"od 1 Hz do 1 MHz","cmc":"2,3·10⁻⁷ Hz"}],"parameters_en":[{"name":"","range":"1 Hz to 1 MHz","cmc":"2,3·10⁻⁷ Hz"}],"parameters_zh":[{"name":"","range":"1 Hz 至 1 MHz","cmc":"2,3·10⁻⁷ Hz"}],"parameters_cs":[{"name":"","range":"1 Hz až 1 MHz","cmc":"2,3·10⁻⁷ Hz"}],"technique":"pomiar bezpośredni licznikiem wzorcowym","technique_en":"direct measurement with a standard counter","technique_zh":"用标准计数器直接测量","technique_cs":"přímé měření etalonovým čítačem","techniques":["pomiar bezpośredni licznikiem wzorcowym"],"techniques_en":["direct measurement with a standard counter"],"techniques_zh":["用标准计数器直接测量"],"techniques_cs":["přímé měření etalonovým čítačem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – czas, częstotliwość\nod 1 Hz do 1 MHz CMC 2,3·10⁻⁷ Hz\npomiar bezpośredni licznikiem wzorcowym","reference":"I 540 – 068 – 44","norm_bases":["I 540 – 068 – 44"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: czas, częstotliwość","regulatory_area_en":"CMC for the field of measured quantity: Time, frequency","regulatory_area_zh":"被测量领域的CMC：时间、频率","regulatory_area_cs":"CMC pro obor měřené veličiny: Čas, frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pomiar częstotliwości, generatory częstotliwości, cyfrowe kamery szybkie, skrzynki synchronizacyjne, podstawy czasu przyrządów i systemów pomiarowych, liczniki i mierniki częstotliwości Wzorcowanie – czas, częstotliwość pomiar bezpośredni licznikiem wzorcowym od 1 Hz do 1 MHz CMC 2,3·10⁻⁷ Hz Měření frekvence, frekvenční generátory, digitální rychlokamery, synchronizační boxy, časové základny měřicích přístrojů a systémů, čítače a měřiče frekvence Kalibrace – čas, frekvence přímé měření etalonovým čítačem 1 Hz až 1 MHz CMC 2,3·10⁻⁷ Hz I 540 – 068 – 44 Pomiar czestotliwosci, generatory czestotliwosci, cyfrowe kamery szybkie, skrzynki synchronizacyjne, podstawy czasu przyrzadow i systemow pomiarowych, liczniki i mierniki czestotliwosci Wzorcowanie – czas, czestotliwosc pomiar bezposredni licznikiem wzorcowym od 1 Hz do 1 MHz CMC 2,3·10⁻⁷ Hz Mereni frekvence, frekvencni generatory, digitalni rychlokamery, synchronizacni boxy, casove zakladny mericich pristroju a systemu, citace a merice frekvence Kalibrace – cas, frekvence prime mereni etalonovym citacem 1 Hz az 1 MHz CMC 2,3·10⁻⁷ Hz I 540 – 068 – 44","search_en":"Frequency measurement, frequency generators, digital speed cameras, synchronization boxes, time bases for measuring instruments and systems, counters and frequency meters Calibration – time, frequency direct measurement with a standard counter 1 Hz to 1 MHz CMC 2,3·10⁻⁷ Hz I 540 – 068 – 44","search_zh":"频率测量、频率发生器、数字高速摄像机、同步盒、测量仪器和系统的时基、计数器和频率计 校准 – 时间、频率 用标准计数器直接测量 1 Hz 至 1 MHz CMC 2,3·10⁻⁷ Hz I 540 – 068 – 44","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b6e9700414396296984e8e0d","lab_id":"6ade8b52ff06824761708141","country":"CZ","accr_number":"2405","accr_body":"ČIA","row_label":"2","test_object":"Przedział czasu / stopery, czasomierze i inne przyrządy do pomiaru czasu","test_object_en":"Time interval / stopwatches, timers and other chronometers","test_object_zh":"时间间隔 / 秒表、定时器和其他计时器具","test_object_cs":"Časový interval / stopky, časovače a jiná měřidla času","methodology":"Wzorcowanie – czas, częstotliwość","methodology_en":"Calibration – time, frequency","methodology_zh":"校准 – 时间、频率","methodology_cs":"Kalibrace – čas, frekvence","parameters":[{"name":"","range":"od 1 ms do 1000 ms","cmc":"1,0·10⁻⁵ s"},{"name":"","range":"od 1 s do 10800 s","cmc":"6,0·10⁻⁴ s"}],"parameters_en":[{"name":"","range":"1 ms to 1000 ms","cmc":"1,0·10⁻⁵ s"},{"name":"","range":"1 s to 10800 s","cmc":"6,0·10⁻⁴ s"}],"parameters_zh":[{"name":"","range":"1 ms 至 1000 ms","cmc":"1,0·10⁻⁵ s"},{"name":"","range":"1 s 至 10800 s","cmc":"6,0·10⁻⁴ s"}],"parameters_cs":[{"name":"","range":"1 ms až 1000 ms","cmc":"1,0·10⁻⁵ s"},{"name":"","range":"1 s až 10800 s","cmc":"6,0·10⁻⁴ s"}],"technique":"porównanie z licznikiem wzorcowym","technique_en":"comparison with a standard counter","technique_zh":"与标准计数器比较","technique_cs":"porovnání s etalonovým čítačem","techniques":["porównanie z licznikiem wzorcowym"],"techniques_en":["comparison with a standard counter"],"techniques_zh":["与标准计数器比较"],"techniques_cs":["porovnání s etalonovým čítačem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – czas, częstotliwość\nZakres:\nod 1 ms do 1000 ms CMC 1,0·10⁻⁵ s\nod 1 s do 10800 s CMC 6,0·10⁻⁴ s\nporównanie z licznikiem wzorcowym","reference":"I 540 – 068 – 02","norm_bases":["I 540 – 068 – 02"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: czas, częstotliwość","regulatory_area_en":"CMC for the field of measured quantity: Time, frequency","regulatory_area_zh":"被测量领域的CMC：时间、频率","regulatory_area_cs":"CMC pro obor měřené veličiny: Čas, frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przedział czasu / stopery, czasomierze i inne przyrządy do pomiaru czasu Wzorcowanie – czas, częstotliwość porównanie z licznikiem wzorcowym od 1 ms do 1000 ms CMC 1,0·10⁻⁵ s od 1 s do 10800 s CMC 6,0·10⁻⁴ s Časový interval / stopky, časovače a jiná měřidla času Kalibrace – čas, frekvence porovnání s etalonovým čítačem 1 ms až 1000 ms CMC 1,0·10⁻⁵ s 1 s až 10800 s CMC 6,0·10⁻⁴ s I 540 – 068 – 02 Przedzial czasu / stopery, czasomierze i inne przyrzady do pomiaru czasu Wzorcowanie – czas, czestotliwosc porownanie z licznikiem wzorcowym od 1 ms do 1000 ms CMC 1,0·10⁻⁵ s od 1 s do 10800 s CMC 6,0·10⁻⁴ s Casovy interval / stopky, casovace a jina meridla casu Kalibrace – cas, frekvence porovnani s etalonovym citacem 1 ms az 1000 ms CMC 1,0·10⁻⁵ s 1 s az 10800 s CMC 6,0·10⁻⁴ s I 540 – 068 – 02","search_en":"Time interval / stopwatches, timers and other chronometers Calibration – time, frequency comparison with a standard counter 1 ms to 1000 ms CMC 1,0·10⁻⁵ s 1 s to 10800 s CMC 6,0·10⁻⁴ s I 540 – 068 – 02","search_zh":"时间间隔 / 秒表、定时器和其他计时器具 校准 – 时间、频率 与标准计数器比较 1 ms 至 1000 ms CMC 1,0·10⁻⁵ s 1 s 至 10800 s CMC 6,0·10⁻⁴ s I 540 – 068 – 02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}