{"lab":{"_id":"6ade8b4eff0682476170813c","country":"CZ","accr_number":"2400","accr_body":"ČIA","address":"Levínský Vršek 147, Levín, 267 01 Králův Dvůr","categories":["metrology"],"city":"Králův Dvůr","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[14.0102946,49.9339713]},"map_coord":[49.9339713,14.0102946],"map_geo":"cai-mapa","methods_count":5,"name":"MV Lab, s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinach: temperatura i wilgotność powietrza, w zakresie określonym w załączniku do świadectwa.","search_text":"mv lab, s.r.o. levínský vršek 147, levín, 267 01 králův dvůr 2400","source_page_url":"https://www.cai.cz/?subjekt=2400-mv-lab-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"05-06-2031","website":"www.mvlab.cz","certificate_date":"05.06.2026","certificate_no":"276/2026","certificate_replaces":"155/2025 z 28.03.2025","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinach: temperatura i wilgotność powietrza, w zakresie określonym w załączniku do świadectwa.","en":"Calibration in the field of temperature and humidity of air to the extent as specified in the appendix to this Certificate.","zh":"温度和空气湿度领域的校准，范围见本证书附件。","cs":"Kalibrace v oborech teplota a vlhkost vzduchu, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium metrologiczne","lab_division_cs":"Metrologická laboratoř","lab_division_en":"Metrology Laboratory","lab_division_zh":"计量实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"878d1c45094155fe00328ece73ca6f8e8d2fb07098d66ef9ba6680979856a18b","source_pdf_url":"https://www.cai.cz/OA/pdf/276_2026_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/276_2026_EN.pdf"},"methods":[{"_id":"a628a13644e71956ec082160","lab_id":"6ade8b4eff0682476170813c","country":"CZ","accr_number":"2400","accr_body":"ČIA","row_label":"1","test_object":"Termometry wskazujące i tory pomiarowe temperatury","test_object_en":"Indicating thermometers and temperature measuring chains","test_object_zh":"指示式温度计和温度测量链","test_object_cs":"Indikační teploměry a měřicí řetězce teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"-196 °C","cmc":"0,13 °C"}],"parameters_en":[{"name":"","range":"-196 °C","cmc":"0,13 °C"}],"parameters_zh":[{"name":"","range":"-196 °C","cmc":"0,13 °C"}],"parameters_cs":[{"name":"","range":"-196 °C","cmc":"0,13 °C"}],"technique":"Porównanie z cyfrowym termometrem wzorcowym w pobliżu punktu wrzenia azotu","technique_en":"Comparison with a standard digital thermometer around the boiling point of nitrogen","technique_zh":"在氮沸点附近与标准数字温度计比较","technique_cs":"Porovnání s etalonovým digitálním teploměrem v okolí bodu varu dusíku","techniques":["Porównanie z cyfrowym termometrem wzorcowym w pobliżu punktu wrzenia azotu"],"techniques_en":["Comparison with a standard digital thermometer around the boiling point of nitrogen"],"techniques_zh":["在氮沸点附近与标准数字温度计比较"],"techniques_cs":["Porovnání s etalonovým digitálním teploměrem v okolí bodu varu dusíku"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\n-196 °C CMC 0,13 °C\nPorównanie z cyfrowym termometrem wzorcowym w pobliżu punktu wrzenia azotu","reference":"PP-M01-1","norm_bases":["PP-M01-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry wskazujące i tory pomiarowe temperatury Wzorcowanie – temperatura Porównanie z cyfrowym termometrem wzorcowym w pobliżu punktu wrzenia azotu -196 °C CMC 0,13 °C Indikační teploměry a měřicí řetězce teploty Kalibrace – teplota Porovnání s etalonovým digitálním teploměrem v okolí bodu varu dusíku -196 °C CMC 0,13 °C PP-M01-1 Termometry wskazujace i tory pomiarowe temperatury Wzorcowanie – temperatura Porownanie z cyfrowym termometrem wzorcowym w poblizu punktu wrzenia azotu -196 °C CMC 0,13 °C Indikacni teplomery a merici retezce teploty Kalibrace – teplota Porovnani s etalonovym digitalnim teplomerem v okoli bodu varu dusiku -196 °C CMC 0,13 °C PP-M01-1","search_en":"Indicating thermometers and temperature measuring chains Calibration – temperature Comparison with a standard digital thermometer around the boiling point of nitrogen -196 °C CMC 0,13 °C PP-M01-1","search_zh":"指示式温度计和温度测量链 校准 – 温度 在氮沸点附近与标准数字温度计比较 -196 °C CMC 0,13 °C PP-M01-1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"928a0ab81f1d94f689a94b1f","lab_id":"6ade8b4eff0682476170813c","country":"CZ","accr_number":"2400","accr_body":"ČIA","row_label":"1","test_object":"Termometry wskazujące i tory pomiarowe temperatury","test_object_en":"Indicating thermometers and temperature measuring chains","test_object_zh":"指示式温度计和温度测量链","test_object_cs":"Indikační teploměry a měřicí řetězce teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -196 °C do -90 °C","cmc":"0,3 °C"}],"parameters_en":[{"name":"","range":"-196 °C to -90 °C","cmc":"0,3 °C"}],"parameters_zh":[{"name":"","range":"-196 °C 至 -90 °C","cmc":"0,3 °C"}],"parameters_cs":[{"name":"","range":"-196 °C až -90 °C","cmc":"0,3 °C"}],"technique":"Porównanie z cyfrowym termometrem wzorcowym na urządzeniu klienta","technique_en":"Comparison with a standard digital thermometer on a customer's device","technique_zh":"在客户设备上与标准数字温度计比较","technique_cs":"Porovnání s etalonovým digitálním teploměrem na zařízení zákazníka","techniques":["Porównanie z cyfrowym termometrem wzorcowym na urządzeniu klienta"],"techniques_en":["Comparison with a standard digital thermometer on a customer's device"],"techniques_zh":["在客户设备上与标准数字温度计比较"],"techniques_cs":["Porovnání s etalonovým digitálním teploměrem na zařízení zákazníka"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod -196 °C do -90 °C CMC 0,3 °C\nPorównanie z cyfrowym termometrem wzorcowym na urządzeniu klienta","reference":"PP-M01-1","norm_bases":["PP-M01-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry wskazujące i tory pomiarowe temperatury Wzorcowanie – temperatura Porównanie z cyfrowym termometrem wzorcowym na urządzeniu klienta od -196 °C do -90 °C CMC 0,3 °C Indikační teploměry a měřicí řetězce teploty Kalibrace – teplota Porovnání s etalonovým digitálním teploměrem na zařízení zákazníka -196 °C až -90 °C CMC 0,3 °C PP-M01-1 Termometry wskazujace i tory pomiarowe temperatury Wzorcowanie – temperatura Porownanie z cyfrowym termometrem wzorcowym na urzadzeniu klienta od -196 °C do -90 °C CMC 0,3 °C Indikacni teplomery a merici retezce teploty Kalibrace – teplota Porovnani s etalonovym digitalnim teplomerem na zarizeni zakaznika -196 °C az -90 °C CMC 0,3 °C PP-M01-1","search_en":"Indicating thermometers and temperature measuring chains Calibration – temperature Comparison with a standard digital thermometer on a customer's device -196 °C to -90 °C CMC 0,3 °C PP-M01-1","search_zh":"指示式温度计和温度测量链 校准 – 温度 在客户设备上与标准数字温度计比较 -196 °C 至 -90 °C CMC 0,3 °C PP-M01-1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6f3bec09563732c4b5e29993","lab_id":"6ade8b4eff0682476170813c","country":"CZ","accr_number":"2400","accr_body":"ČIA","row_label":"1","test_object":"Termometry wskazujące i tory pomiarowe temperatury","test_object_en":"Indicating thermometers and temperature measuring chains","test_object_zh":"指示式温度计和温度测量链","test_object_cs":"Indikační teploměry a měřicí řetězce teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -90 °C do -45 °C","cmc":"0,09 °C"},{"name":"","range":"od -45 °C do 0 °C","cmc":"0,07 °C"},{"name":"","range":"od 0 °C do 45 °C","cmc":"0,07 °C"},{"name":"","range":"od 45 °C do 155 °C","cmc":"0,08 °C"},{"name":"","range":"od 155 °C do 250 °C","cmc":"0,4 °C"},{"name":"","range":"od 250 °C do 450 °C","cmc":"0,6 °C"},{"name":"","range":"od 450 °C do 650 °C","cmc":"0,7 °C"}],"parameters_en":[{"name":"","range":"-90 °C to -45 °C","cmc":"0,09 °C"},{"name":"","range":"-45 °C to 0 °C","cmc":"0,07 °C"},{"name":"","range":"0 °C to 45 °C","cmc":"0,07 °C"},{"name":"","range":"45 °C to 155 °C","cmc":"0,08 °C"},{"name":"","range":"155 °C to 250 °C","cmc":"0,4 °C"},{"name":"","range":"250 °C to 450 °C","cmc":"0,6 °C"},{"name":"","range":"450 °C to 650 °C","cmc":"0,7 °C"}],"parameters_zh":[{"name":"","range":"-90 °C 至 -45 °C","cmc":"0,09 °C"},{"name":"","range":"-45 °C 至 0 °C","cmc":"0,07 °C"},{"name":"","range":"0 °C 至 45 °C","cmc":"0,07 °C"},{"name":"","range":"45 °C 至 155 °C","cmc":"0,08 °C"},{"name":"","range":"155 °C 至 250 °C","cmc":"0,4 °C"},{"name":"","range":"250 °C 至 450 °C","cmc":"0,6 °C"},{"name":"","range":"450 °C 至 650 °C","cmc":"0,7 °C"}],"parameters_cs":[{"name":"","range":"-90 °C až -45 °C","cmc":"0,09 °C"},{"name":"","range":"-45 °C až 0 °C","cmc":"0,07 °C"},{"name":"","range":"0 °C až 45 °C","cmc":"0,07 °C"},{"name":"","range":"45 °C až 155 °C","cmc":"0,08 °C"},{"name":"","range":"155 °C až 250 °C","cmc":"0,4 °C"},{"name":"","range":"250 °C až 450 °C","cmc":"0,6 °C"},{"name":"","range":"450 °C až 650 °C","cmc":"0,7 °C"}],"technique":"Porównanie z cyfrowym termometrem wzorcowym w piecu wzorcującym","technique_en":"Comparison with a standard digital thermometer in a calibration oven","technique_zh":"在校准炉中与标准数字温度计比较","technique_cs":"Porovnání s etalonovým digitálním teploměrem v kalibrační pícce","techniques":["Porównanie z cyfrowym termometrem wzorcowym w piecu wzorcującym"],"techniques_en":["Comparison with a standard digital thermometer in a calibration oven"],"techniques_zh":["在校准炉中与标准数字温度计比较"],"techniques_cs":["Porovnání s etalonovým digitálním teploměrem v kalibrační pícce"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -90 °C do -45 °C CMC 0,09 °C\nod -45 °C do 0 °C CMC 0,07 °C\nod 0 °C do 45 °C CMC 0,07 °C\nod 45 °C do 155 °C CMC 0,08 °C\nod 155 °C do 250 °C CMC 0,4 °C\nod 250 °C do 450 °C CMC 0,6 °C\nod 450 °C do 650 °C CMC 0,7 °C\nPorównanie z cyfrowym termometrem wzorcowym w piecu wzorcującym","reference":"PP-M01-1","norm_bases":["PP-M01-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry wskazujące i tory pomiarowe temperatury Wzorcowanie – temperatura Porównanie z cyfrowym termometrem wzorcowym w piecu wzorcującym od -90 °C do -45 °C CMC 0,09 °C od -45 °C do 0 °C CMC 0,07 °C od 0 °C do 45 °C CMC 0,07 °C od 45 °C do 155 °C CMC 0,08 °C od 155 °C do 250 °C CMC 0,4 °C od 250 °C do 450 °C CMC 0,6 °C od 450 °C do 650 °C CMC 0,7 °C Indikační teploměry a měřicí řetězce teploty Kalibrace – teplota Porovnání s etalonovým digitálním teploměrem v kalibrační pícce -90 °C až -45 °C CMC 0,09 °C -45 °C až 0 °C CMC 0,07 °C 0 °C až 45 °C CMC 0,07 °C 45 °C až 155 °C CMC 0,08 °C 155 °C až 250 °C CMC 0,4 °C 250 °C až 450 °C CMC 0,6 °C 450 °C až 650 °C CMC 0,7 °C PP-M01-1 Termometry wskazujace i tory pomiarowe temperatury Wzorcowanie – temperatura Porownanie z cyfrowym termometrem wzorcowym w piecu wzorcujacym od -90 °C do -45 °C CMC 0,09 °C od -45 °C do 0 °C CMC 0,07 °C od 0 °C do 45 °C CMC 0,07 °C od 45 °C do 155 °C CMC 0,08 °C od 155 °C do 250 °C CMC 0,4 °C od 250 °C do 450 °C CMC 0,6 °C od 450 °C do 650 °C CMC 0,7 °C Indikacni teplomery a merici retezce teploty Kalibrace – teplota Porovnani s etalonovym digitalnim teplomerem v kalibracni picce -90 °C az -45 °C CMC 0,09 °C -45 °C az 0 °C CMC 0,07 °C 0 °C az 45 °C CMC 0,07 °C 45 °C az 155 °C CMC 0,08 °C 155 °C az 250 °C CMC 0,4 °C 250 °C az 450 °C CMC 0,6 °C 450 °C az 650 °C CMC 0,7 °C PP-M01-1","search_en":"Indicating thermometers and temperature measuring chains Calibration – temperature Comparison with a standard digital thermometer in a calibration oven -90 °C to -45 °C CMC 0,09 °C -45 °C to 0 °C CMC 0,07 °C 0 °C to 45 °C CMC 0,07 °C 45 °C to 155 °C CMC 0,08 °C 155 °C to 250 °C CMC 0,4 °C 250 °C to 450 °C CMC 0,6 °C 450 °C to 650 °C CMC 0,7 °C PP-M01-1","search_zh":"指示式温度计和温度测量链 校准 – 温度 在校准炉中与标准数字温度计比较 -90 °C 至 -45 °C CMC 0,09 °C -45 °C 至 0 °C CMC 0,07 °C 0 °C 至 45 °C CMC 0,07 °C 45 °C 至 155 °C CMC 0,08 °C 155 °C 至 250 °C CMC 0,4 °C 250 °C 至 450 °C CMC 0,6 °C 450 °C 至 650 °C CMC 0,7 °C PP-M01-1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"10d8e8612c385defa10ddcca","lab_id":"6ade8b4eff0682476170813c","country":"CZ","accr_number":"2400","accr_body":"ČIA","row_label":"1","test_object":"Termometry wskazujące i tory pomiarowe temperatury","test_object_en":"Indicating thermometers and temperature measuring chains","test_object_zh":"指示式温度计和温度测量链","test_object_cs":"Indikační teploměry a měřicí řetězce teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"0,01 °C","cmc":"0,03 °C"}],"parameters_en":[{"name":"","range":"0,01 °C","cmc":"0,03 °C"}],"parameters_zh":[{"name":"","range":"0,01 °C","cmc":"0,03 °C"}],"parameters_cs":[{"name":"","range":"0,01 °C","cmc":"0,03 °C"}],"technique":"Pomiar bezpośredni w punkcie potrójnym wody","technique_en":"Direct measurement at the triple point of water","technique_zh":"在水三相点直接测量","technique_cs":"Přímé měření v trojném bodě vody","techniques":["Pomiar bezpośredni w punkcie potrójnym wody"],"techniques_en":["Direct measurement at the triple point of water"],"techniques_zh":["在水三相点直接测量"],"techniques_cs":["Přímé měření v trojném bodě vody"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\n0,01 °C CMC 0,03 °C\nPomiar bezpośredni w punkcie potrójnym wody","reference":"PP-M01-1","norm_bases":["PP-M01-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry wskazujące i tory pomiarowe temperatury Wzorcowanie – temperatura Pomiar bezpośredni w punkcie potrójnym wody 0,01 °C CMC 0,03 °C Indikační teploměry a měřicí řetězce teploty Kalibrace – teplota Přímé měření v trojném bodě vody 0,01 °C CMC 0,03 °C PP-M01-1 Termometry wskazujace i tory pomiarowe temperatury Wzorcowanie – temperatura Pomiar bezposredni w punkcie potrojnym wody 0,01 °C CMC 0,03 °C Indikacni teplomery a merici retezce teploty Kalibrace – teplota Prime mereni v trojnem bode vody 0,01 °C CMC 0,03 °C PP-M01-1","search_en":"Indicating thermometers and temperature measuring chains Calibration – temperature Direct measurement at the triple point of water 0,01 °C CMC 0,03 °C PP-M01-1","search_zh":"指示式温度计和温度测量链 校准 – 温度 在水三相点直接测量 0,01 °C CMC 0,03 °C PP-M01-1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3a7577f86423ee9654d1ca24","lab_id":"6ade8b4eff0682476170813c","country":"CZ","accr_number":"2400","accr_body":"ČIA","row_label":"1","test_object":"Higrometry elektroniczne i tory pomiarowe wilgotności względnej","test_object_en":"Electronic hygrometers and relative humidity measuring chains","test_object_zh":"电子湿度计和相对湿度测量链","test_object_cs":"Elektronické vlhkoměry a měřicí řetězce relativní vlhkosti","methodology":"Wzorcowanie – wilgotność powietrza","methodology_en":"Calibration – air humidity","methodology_zh":"校准 – 空气湿度","methodology_cs":"Kalibrace – vlhkost vzduchu","parameters":[{"name":"(10 – 25) °C","range":"od 5 % RH do 20 % RH","cmc":"0,6 % RH"},{"name":"(10 – 25) °C","range":"od 20 % RH do 40 % RH","cmc":"0,7 % RH"},{"name":"(10 – 25) °C","range":"od 40 % RH do 50 % RH","cmc":"0,8 % RH"},{"name":"(10 – 25) °C","range":"od 50 % RH do 60 % RH","cmc":"0,9 % RH"},{"name":"(10 – 25) °C","range":"od 60 % RH do 80 % RH","cmc":"1,0 % RH"},{"name":"(10 – 25) °C","range":"od 80 % RH do 90 % RH","cmc":"1,1 % RH"},{"name":"(10 – 25) °C","range":"od 90 % RH do 95 % RH","cmc":"1,2 % RH"},{"name":"(25 – 40) °C","range":"od 5 % RH do 30 % RH","cmc":"0,6 % RH"},{"name":"(25 – 40) °C","range":"od 30 % RH do 40 % RH","cmc":"0,7 % RH"},{"name":"(25 – 40) °C","range":"od 40 % RH do 60 % RH","cmc":"0,8 % RH"},{"name":"(25 – 40) °C","range":"od 60 % RH do 70 % RH","cmc":"0,9 % RH"},{"name":"(25 – 40) °C","range":"od 70 % RH do 90 % RH","cmc":"1,0 % RH"},{"name":"(25 – 40) °C","range":"od 90 % RH do 95 % RH","cmc":"1,1 % RH"}],"parameters_en":[{"name":"(10 – 25) °C","range":"5 % RH to 20 % RH","cmc":"0,6 % RH"},{"name":"(10 – 25) °C","range":"20 % RH to 40 % RH","cmc":"0,7 % RH"},{"name":"(10 – 25) °C","range":"40 % RH to 50 % RH","cmc":"0,8 % RH"},{"name":"(10 – 25) °C","range":"50 % RH to 60 % RH","cmc":"0,9 % RH"},{"name":"(10 – 25) °C","range":"60 % RH to 80 % RH","cmc":"1,0 % RH"},{"name":"(10 – 25) °C","range":"80 % RH to 90 % RH","cmc":"1,1 % RH"},{"name":"(10 – 25) °C","range":"90 % RH to 95 % RH","cmc":"1,2 % RH"},{"name":"(25 – 40) °C","range":"5 % RH to 30 % RH","cmc":"0,6 % RH"},{"name":"(25 – 40) °C","range":"30 % RH to 40 % RH","cmc":"0,7 % RH"},{"name":"(25 – 40) °C","range":"40 % RH to 60 % RH","cmc":"0,8 % RH"},{"name":"(25 – 40) °C","range":"60 % RH to 70 % RH","cmc":"0,9 % RH"},{"name":"(25 – 40) °C","range":"70 % RH to 90 % RH","cmc":"1,0 % RH"},{"name":"(25 – 40) °C","range":"90 % RH to 95 % RH","cmc":"1,1 % RH"}],"parameters_zh":[{"name":"(10 – 25) °C","range":"5 % RH 至 20 % RH","cmc":"0,6 % RH"},{"name":"(10 – 25) °C","range":"20 % RH 至 40 % RH","cmc":"0,7 % RH"},{"name":"(10 – 25) °C","range":"40 % RH 至 50 % RH","cmc":"0,8 % RH"},{"name":"(10 – 25) °C","range":"50 % RH 至 60 % RH","cmc":"0,9 % RH"},{"name":"(10 – 25) °C","range":"60 % RH 至 80 % RH","cmc":"1,0 % RH"},{"name":"(10 – 25) °C","range":"80 % RH 至 90 % RH","cmc":"1,1 % RH"},{"name":"(10 – 25) °C","range":"90 % RH 至 95 % RH","cmc":"1,2 % RH"},{"name":"(25 – 40) °C","range":"5 % RH 至 30 % RH","cmc":"0,6 % RH"},{"name":"(25 – 40) °C","range":"30 % RH 至 40 % RH","cmc":"0,7 % RH"},{"name":"(25 – 40) °C","range":"40 % RH 至 60 % RH","cmc":"0,8 % RH"},{"name":"(25 – 40) °C","range":"60 % RH 至 70 % RH","cmc":"0,9 % RH"},{"name":"(25 – 40) °C","range":"70 % RH 至 90 % RH","cmc":"1,0 % RH"},{"name":"(25 – 40) °C","range":"90 % RH 至 95 % RH","cmc":"1,1 % RH"}],"parameters_cs":[{"name":"(10 – 25) °C","range":"5 % RH až 20 % RH","cmc":"0,6 % RH"},{"name":"(10 – 25) °C","range":"20 % RH až 40 % RH","cmc":"0,7 % RH"},{"name":"(10 – 25) °C","range":"40 % RH až 50 % RH","cmc":"0,8 % RH"},{"name":"(10 – 25) °C","range":"50 % RH až 60 % RH","cmc":"0,9 % RH"},{"name":"(10 – 25) °C","range":"60 % RH až 80 % RH","cmc":"1,0 % RH"},{"name":"(10 – 25) °C","range":"80 % RH až 90 % RH","cmc":"1,1 % RH"},{"name":"(10 – 25) °C","range":"90 % RH až 95 % RH","cmc":"1,2 % RH"},{"name":"(25 – 40) °C","range":"5 % RH až 30 % RH","cmc":"0,6 % RH"},{"name":"(25 – 40) °C","range":"30 % RH až 40 % RH","cmc":"0,7 % RH"},{"name":"(25 – 40) °C","range":"40 % RH až 60 % RH","cmc":"0,8 % RH"},{"name":"(25 – 40) °C","range":"60 % RH až 70 % RH","cmc":"0,9 % RH"},{"name":"(25 – 40) °C","range":"70 % RH až 90 % RH","cmc":"1,0 % RH"},{"name":"(25 – 40) °C","range":"90 % RH až 95 % RH","cmc":"1,1 % RH"}],"technique":"Porównanie z wzorcowym higrometrem punktu rosy w generatorze wilgotności","technique_en":"Comparison with a standard dew point hygrometer in a humidity generator","technique_zh":"在湿度发生器中与标准露点湿度计比较","technique_cs":"Porovnání s etalonovým rosnobodovým vlhkoměrem v generátoru vlhkosti","techniques":["Porównanie z wzorcowym higrometrem punktu rosy w generatorze wilgotności"],"techniques_en":["Comparison with a standard dew point hygrometer in a humidity generator"],"techniques_zh":["在湿度发生器中与标准露点湿度计比较"],"techniques_cs":["Porovnání s etalonovým rosnobodovým vlhkoměrem v generátoru vlhkosti"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wilgotność powietrza\nZakres:\n(10 – 25) °C od 5 % RH do 20 % RH CMC 0,6 % RH\n(10 – 25) °C od 20 % RH do 40 % RH CMC 0,7 % RH\n(10 – 25) °C od 40 % RH do 50 % RH CMC 0,8 % RH\n(10 – 25) °C od 50 % RH do 60 % RH CMC 0,9 % RH\n(10 – 25) °C od 60 % RH do 80 % RH CMC 1,0 % RH\n(10 – 25) °C od 80 % RH do 90 % RH CMC 1,1 % RH\n(10 – 25) °C od 90 % RH do 95 % RH CMC 1,2 % RH\n(25 – 40) °C od 5 % RH do 30 % RH CMC 0,6 % RH\n(25 – 40) °C od 30 % RH do 40 % RH CMC 0,7 % RH\n(25 – 40) °C od 40 % RH do 60 % RH CMC 0,8 % RH\n(25 – 40) °C od 60 % RH do 70 % RH CMC 0,9 % RH\n(25 – 40) °C od 70 % RH do 90 % RH CMC 1,0 % RH\n(25 – 40) °C od 90 % RH do 95 % RH CMC 1,1 % RH\nPorównanie z wzorcowym higrometrem punktu rosy w generatorze wilgotności","reference":"PP-M02-1","norm_bases":["PP-M02-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wilgotność powietrza","regulatory_area_en":"CMC for the field of measured quantity: Air humidity","regulatory_area_zh":"被测量领域的CMC：空气湿度","regulatory_area_cs":"CMC pro obor měřené veličiny: Vlhkost vzduchu","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Higrometry elektroniczne i tory pomiarowe wilgotności względnej Wzorcowanie – wilgotność powietrza Porównanie z wzorcowym higrometrem punktu rosy w generatorze wilgotności (10 – 25) °C od 5 % RH do 20 % RH CMC 0,6 % RH (10 – 25) °C od 20 % RH do 40 % RH CMC 0,7 % RH (10 – 25) °C od 40 % RH do 50 % RH CMC 0,8 % RH (10 – 25) °C od 50 % RH do 60 % RH CMC 0,9 % RH (10 – 25) °C od 60 % RH do 80 % RH CMC 1,0 % RH (10 – 25) °C od 80 % RH do 90 % RH CMC 1,1 % RH (10 – 25) °C od 90 % RH do 95 % RH CMC 1,2 % RH (25 – 40) °C od 5 % RH do 30 % RH CMC 0,6 % RH (25 – 40) °C od 30 % RH do 40 % RH CMC 0,7 % RH (25 – 40) °C od 40 % RH do 60 % RH CMC 0,8 % RH (25 – 40) °C od 60 % RH do 70 % RH CMC 0,9 % RH (25 – 40) °C od 70 % RH do 90 % RH CMC 1,0 % RH (25 – 40) °C od 90 % RH do 95 % RH CMC 1,1 % RH Elektronické vlhkoměry a měřicí řetězce relativní vlhkosti Kalibrace – vlhkost vzduchu Porovnání s etalonovým rosnobodovým vlhkoměrem v generátoru vlhkosti (10 – 25) °C 5 % RH až 20 % RH CMC 0,6 % RH (10 – 25) °C 20 % RH až 40 % RH CMC 0,7 % RH (10 – 25) °C 40 % RH až 50 % RH CMC 0,8 % RH (10 – 25) °C 50 % RH až 60 % RH CMC 0,9 % RH (10 – 25) °C 60 % RH až 80 % RH CMC 1,0 % RH (10 – 25) °C 80 % RH až 90 % RH CMC 1,1 % RH (10 – 25) °C 90 % RH až 95 % RH CMC 1,2 % RH (25 – 40) °C 5 % RH až 30 % RH CMC 0,6 % RH (25 – 40) °C 30 % RH až 40 % RH CMC 0,7 % RH (25 – 40) °C 40 % RH až 60 % RH CMC 0,8 % RH (25 – 40) °C 60 % RH až 70 % RH CMC 0,9 % RH (25 – 40) °C 70 % RH až 90 % RH CMC 1,0 % RH (25 – 40) °C 90 % RH až 95 % RH CMC 1,1 % RH PP-M02-1 Higrometry elektroniczne i tory pomiarowe wilgotnosci wzglednej Wzorcowanie – wilgotnosc powietrza Porownanie z wzorcowym higrometrem punktu rosy w generatorze wilgotnosci (10 – 25) °C od 5 % RH do 20 % RH CMC 0,6 % RH (10 – 25) °C od 20 % RH do 40 % RH CMC 0,7 % RH (10 – 25) °C od 40 % RH do 50 % RH CMC 0,8 % RH (10 – 25) °C od 50 % RH do 60 % RH CMC 0,9 % RH (10 – 25) °C od 60 % RH do 80 % RH CMC 1,0 % RH (10 – 25) °C od 80 % RH do 90 % RH CMC 1,1 % RH (10 – 25) °C od 90 % RH do 95 % RH CMC 1,2 % RH (25 – 40) °C od 5 % RH do 30 % RH CMC 0,6 % RH (25 – 40) °C od 30 % RH do 40 % RH CMC 0,7 % RH (25 – 40) °C od 40 % RH do 60 % RH CMC 0,8 % RH (25 – 40) °C od 60 % RH do 70 % RH CMC 0,9 % RH (25 – 40) °C od 70 % RH do 90 % RH CMC 1,0 % RH (25 – 40) °C od 90 % RH do 95 % RH CMC 1,1 % RH Elektronicke vlhkomery a merici retezce relativni vlhkosti Kalibrace – vlhkost vzduchu Porovnani s etalonovym rosnobodovym vlhkomerem v generatoru vlhkosti (10 – 25) °C 5 % RH az 20 % RH CMC 0,6 % RH (10 – 25) °C 20 % RH az 40 % RH CMC 0,7 % RH (10 – 25) °C 40 % RH az 50 % RH CMC 0,8 % RH (10 – 25) °C 50 % RH az 60 % RH CMC 0,9 % RH (10 – 25) °C 60 % RH az 80 % RH CMC 1,0 % RH (10 – 25) °C 80 % RH az 90 % RH CMC 1,1 % RH (10 – 25) °C 90 % RH az 95 % RH CMC 1,2 % RH (25 – 40) °C 5 % RH az 30 % RH CMC 0,6 % RH (25 – 40) °C 30 % RH az 40 % RH CMC 0,7 % RH (25 – 40) °C 40 % RH az 60 % RH CMC 0,8 % RH (25 – 40) °C 60 % RH az 70 % RH CMC 0,9 % RH (25 – 40) °C 70 % RH az 90 % RH CMC 1,0 % RH (25 – 40) °C 90 % RH az 95 % RH CMC 1,1 % RH PP-M02-1","search_en":"Electronic hygrometers and relative humidity measuring chains Calibration – air humidity Comparison with a standard dew point hygrometer in a humidity generator (10 – 25) °C 5 % RH to 20 % RH CMC 0,6 % RH (10 – 25) °C 20 % RH to 40 % RH CMC 0,7 % RH (10 – 25) °C 40 % RH to 50 % RH CMC 0,8 % RH (10 – 25) °C 50 % RH to 60 % RH CMC 0,9 % RH (10 – 25) °C 60 % RH to 80 % RH CMC 1,0 % RH (10 – 25) °C 80 % RH to 90 % RH CMC 1,1 % RH (10 – 25) °C 90 % RH to 95 % RH CMC 1,2 % RH (25 – 40) °C 5 % RH to 30 % RH CMC 0,6 % RH (25 – 40) °C 30 % RH to 40 % RH CMC 0,7 % RH (25 – 40) °C 40 % RH to 60 % RH CMC 0,8 % RH (25 – 40) °C 60 % RH to 70 % RH CMC 0,9 % RH (25 – 40) °C 70 % RH to 90 % RH CMC 1,0 % RH (25 – 40) °C 90 % RH to 95 % RH CMC 1,1 % RH PP-M02-1","search_zh":"电子湿度计和相对湿度测量链 校准 – 空气湿度 在湿度发生器中与标准露点湿度计比较 (10 – 25) °C 5 % RH 至 20 % RH CMC 0,6 % RH (10 – 25) °C 20 % RH 至 40 % RH CMC 0,7 % RH (10 – 25) °C 40 % RH 至 50 % RH CMC 0,8 % RH (10 – 25) °C 50 % RH 至 60 % RH CMC 0,9 % RH (10 – 25) °C 60 % RH 至 80 % RH CMC 1,0 % RH (10 – 25) °C 80 % RH 至 90 % RH CMC 1,1 % RH (10 – 25) °C 90 % RH 至 95 % RH CMC 1,2 % RH (25 – 40) °C 5 % RH 至 30 % RH CMC 0,6 % RH (25 – 40) °C 30 % RH 至 40 % RH CMC 0,7 % RH (25 – 40) °C 40 % RH 至 60 % RH CMC 0,8 % RH (25 – 40) °C 60 % RH 至 70 % RH CMC 0,9 % RH (25 – 40) °C 70 % RH 至 90 % RH CMC 1,0 % RH (25 – 40) °C 90 % RH 至 95 % RH CMC 1,1 % RH PP-M02-1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}