{"lab":{"_id":"6ade8b4dff0682476170813a","accr_number":"2398","country":"CZ","accr_body":"ČIA","address":"Radlická 3201/14, Smíchov, 150 00 Praha 5","categories":["metrology"],"city":"Praha 5","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[14.4010454,50.0705482]},"map_coord":[50.0705482,14.4010454],"map_geo":"cai-mapa","methods_count":3,"name":"Carl Zeiss spol. s r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinie długości, w zakresie określonym w załączniku do świadectwa.","search_text":"carl zeiss spol. s r.o. radlická 3201/14, smíchov, 150 00 praha 5 2398","source_page_url":"https://www.cai.cz/?subjekt=2398-carl-zeiss-spol-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"25-11-2030","website":"www.zeiss.cz","certificate_date":"25.11.2025","certificate_no":"612/2025","certificate_replaces":"518/2024 z 02.10.2024","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinie długości, w zakresie określonym w załączniku do świadectwa.","en":"Calibrations in the field of length to the extent as specified in the appendix to this Certificate.","zh":"长度领域的校准，范围见本证书附件。","cs":"Kalibrace v oboru délka, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące Carl Zeiss IQS","lab_division_cs":"Kalibrační laboratoř Carl Zeiss IQS","lab_division_en":"Calibration Laboratory Carl Zeiss IQS","lab_division_zh":"Carl Zeiss IQS 校准实验室","lab_locations":[{"code":null,"name":"Carl Zeiss spol. s r.o.","street":"Radlická 3201/14, Smíchov","postal_code":"150 00","city":"Praha 5","is_hq":true,"address":"Radlická 3201/14, Smíchov, 150 00 Praha 5","site":"15000|radlická3201/14smíchov"},{"code":null,"name":"Praga - Radlická (nie wykonuje się wzorcowań)","street":"Radlická 3201/14, Smíchov","postal_code":"150 00","city":"Praha 5","is_hq":false,"address":"Radlická 3201/14, Smíchov, 150 00 Praha 5","site":"15000|radlická3201/14smíchov"},{"code":null,"name":"Nupaky","street":"Komerční 524, Nupaky","postal_code":"251 01","city":"Praha - Východ","is_hq":false,"address":"Komerční 524, Nupaky, 251 01 Praha - Východ","site":"25101|komerční524nupaky"}],"lab_locations_en":[{"code":null,"name":"Carl Zeiss spol. s r.o.","street":"Radlická 3201/14, Smíchov","postal_code":"150 00","city":"Praha 5","is_hq":true,"address":"Radlická 3201/14, Smíchov, 150 00 Praha 5","site":"15000|radlická3201/14smíchov"},{"code":null,"name":"Praha - Radlická (does not perform calibrations)","street":"Radlická 3201/14, Smíchov","postal_code":"150 00","city":"Praha 5","is_hq":false,"address":"Radlická 3201/14, Smíchov, 150 00 Praha 5","site":"15000|radlická3201/14smíchov"},{"code":null,"name":"Nupaky","street":"Komerční 524, Nupaky","postal_code":"251 01","city":"Praha - Východ","is_hq":false,"address":"Komerční 524, Nupaky, 251 01 Praha - Východ","site":"25101|komerční524nupaky"}],"lab_locations_zh":[{"code":null,"name":"Carl Zeiss spol. s r.o.","street":"Radlická 3201/14, Smíchov","postal_code":"150 00","city":"Praha 5","is_hq":true,"address":"Radlická 3201/14, Smíchov, 150 00 Praha 5","site":"15000|radlická3201/14smíchov"},{"code":null,"name":"布拉格 - Radlická（不进行校准）","street":"Radlická 3201/14, Smíchov","postal_code":"150 00","city":"Praha 5","is_hq":false,"address":"Radlická 3201/14, Smíchov, 150 00 Praha 5","site":"15000|radlická3201/14smíchov"},{"code":null,"name":"Nupaky 工作场所","street":"Komerční 524, Nupaky","postal_code":"251 01","city":"Praha - Východ","is_hq":false,"address":"Komerční 524, Nupaky, 251 01 Praha - Východ","site":"25101|komerční524nupaky"}],"parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[{"pl":"Laboratorium wydaje opinie i interpretacje wyników wzorcowań.","en":"The laboratory provides opinions and interpretations of the calibration results.","zh":"实验室提供校准结果的意见和解释。","cs":"Laboratoř poskytuje stanoviska a interpretace výsledků kalibrací."}],"source_lang":"cs","source_pdf_sha256":"9691978505a610692b5952d456c42d6fc4c52412e73420527de5dabca489f3fe","source_pdf_url":"https://www.cai.cz/OA/pdf/612_2025_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/612_2025_EN.pdf"},"methods":[{"_id":"eb999e67f2ae23fdc07cffd9","lab_id":"6ade8b4dff0682476170813a","country":"CZ","accr_number":"2398","accr_body":"ČIA","row_label":"1","test_object":"Współrzędnościowe maszyny pomiarowe Carl Zeiss z próbkowaniem stykowym","test_object_en":"Coordinate measuring machines Carl Zeiss with contacting probing","test_object_zh":"带接触式探测的 Carl Zeiss 坐标测量机","test_object_cs":"Souřadnicové měřící stroje Carl Zeiss s dotykovým snímáním","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 3030 mm","cmc":"(0,23·L + 0,06) µm"}],"parameters_en":[{"name":"","range":"0 mm to 3030 mm","cmc":"(0,23·L + 0,06) µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 3030 mm","cmc":"(0,23·L + 0,06) µm"}],"parameters_cs":[{"name":"","range":"0 mm až 3030 mm","cmc":"(0,23·L + 0,06) µm"}],"technique":"Pomiar wzorca schodkowego i kuli wzorcowej (ČSN EN ISO 10360-2, ČSN EN ISO 10360-3, ČSN EN ISO 10360-4, VDI/VDE 2617 Blatt 2.1, VDI/VDE 2617 Blatt 2.2, VDI/VDE 2617 Blatt 4)","technique_en":"Step gauge and calibration ball measurement (ČSN EN ISO 10360-2, ČSN EN ISO 10360-3, ČSN EN ISO 10360-4, VDI/VDE 2617 Blatt 2.1, VDI/VDE 2617 Blatt 2.2, VDI/VDE 2617 Blatt 4)","technique_zh":"测量阶梯规和校准球（ČSN EN ISO 10360-2、ČSN EN ISO 10360-3、ČSN EN ISO 10360-4、VDI/VDE 2617 Blatt 2.1、VDI/VDE 2617 Blatt 2.2、VDI/VDE 2617 Blatt 4）","technique_cs":"Měření stupňové měrky a kalibrační koule (ČSN EN ISO 10360-2, ČSN EN ISO 10360-3, ČSN EN ISO 10360-4, VDI/VDE 2617 Blatt 2.1, VDI/VDE 2617 Blatt 2.2, VDI/VDE 2617 Blatt 4)","techniques":["Pomiar wzorca schodkowego i kuli wzorcowej (ČSN EN ISO 10360-2, ČSN EN ISO 10360-3, ČSN EN ISO 10360-4, VDI/VDE 2617 Blatt 2.1, VDI/VDE 2617 Blatt 2.2, VDI/VDE 2617 Blatt 4)"],"techniques_en":["Step gauge and calibration ball measurement (ČSN EN ISO 10360-2, ČSN EN ISO 10360-3, ČSN EN ISO 10360-4, VDI/VDE 2617 Blatt 2.1, VDI/VDE 2617 Blatt 2.2, VDI/VDE 2617 Blatt 4)"],"techniques_zh":["测量阶梯规和校准球（ČSN EN ISO 10360-2、ČSN EN ISO 10360-3、ČSN EN ISO 10360-4、VDI/VDE 2617 Blatt 2.1、VDI/VDE 2617 Blatt 2.2、VDI/VDE 2617 Blatt 4）"],"techniques_cs":["Měření stupňové měrky a kalibrační koule (ČSN EN ISO 10360-2, ČSN EN ISO 10360-3, ČSN EN ISO 10360-4, VDI/VDE 2617 Blatt 2.1, VDI/VDE 2617 Blatt 2.2, VDI/VDE 2617 Blatt 4)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 3030 mm CMC (0,23·L + 0,06) µm\nPomiar wzorca schodkowego i kuli wzorcowej (ČSN EN ISO 10360-2, ČSN EN ISO 10360-3, ČSN EN ISO 10360-4, VDI/VDE 2617 Blatt 2.1, VDI/VDE 2617 Blatt 2.2, VDI/VDE 2617 Blatt 4)","reference":"KP001-ZEISS-10360, KP002-ZEISS-2617","norm_bases":["KP001-ZEISS-10360","KP002-ZEISS-2617"],"lab_section":"Nupaky","lab_section_en":"Nupaky","lab_section_zh":"Nupaky 工作场所","lab_section_cs":"Nupaky","lab_address":"Komerční 524, Nupaky, 251 01 Praha - Východ","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Współrzędnościowe maszyny pomiarowe Carl Zeiss z próbkowaniem stykowym Wzorcowanie – długość Pomiar wzorca schodkowego i kuli wzorcowej (ČSN EN ISO 10360-2, ČSN EN ISO 10360-3, ČSN EN ISO 10360-4, VDI/VDE 2617 Blatt 2.1, VDI/VDE 2617 Blatt 2.2, VDI/VDE 2617 Blatt 4) od 0 mm do 3030 mm CMC (0,23·L + 0,06) µm Souřadnicové měřící stroje Carl Zeiss s dotykovým snímáním Kalibrace – délka Měření stupňové měrky a kalibrační koule (ČSN EN ISO 10360-2, ČSN EN ISO 10360-3, ČSN EN ISO 10360-4, VDI/VDE 2617 Blatt 2.1, VDI/VDE 2617 Blatt 2.2, VDI/VDE 2617 Blatt 4) 0 mm až 3030 mm CMC (0,23·L + 0,06) µm KP001-ZEISS-10360, KP002-ZEISS-2617 Wspolrzednosciowe maszyny pomiarowe Carl Zeiss z probkowaniem stykowym Wzorcowanie – dlugosc Pomiar wzorca schodkowego i kuli wzorcowej (CSN EN ISO 10360-2, CSN EN ISO 10360-3, CSN EN ISO 10360-4, VDI/VDE 2617 Blatt 2.1, VDI/VDE 2617 Blatt 2.2, VDI/VDE 2617 Blatt 4) od 0 mm do 3030 mm CMC (0,23·L + 0,06) µm Souradnicove merici stroje Carl Zeiss s dotykovym snimanim Kalibrace – delka Mereni stupnove merky a kalibracni koule (CSN EN ISO 10360-2, CSN EN ISO 10360-3, CSN EN ISO 10360-4, VDI/VDE 2617 Blatt 2.1, VDI/VDE 2617 Blatt 2.2, VDI/VDE 2617 Blatt 4) 0 mm az 3030 mm CMC (0,23·L + 0,06) µm KP001-ZEISS-10360, KP002-ZEISS-2617","search_en":"Coordinate measuring machines Carl Zeiss with contacting probing Calibration – length Step gauge and calibration ball measurement (ČSN EN ISO 10360-2, ČSN EN ISO 10360-3, ČSN EN ISO 10360-4, VDI/VDE 2617 Blatt 2.1, VDI/VDE 2617 Blatt 2.2, VDI/VDE 2617 Blatt 4) 0 mm to 3030 mm CMC (0,23·L + 0,06) µm KP001-ZEISS-10360, KP002-ZEISS-2617","search_zh":"带接触式探测的 Carl Zeiss 坐标测量机 校准 – 长度 测量阶梯规和校准球（ČSN EN ISO 10360-2、ČSN EN ISO 10360-3、ČSN EN ISO 10360-4、VDI/VDE 2617 Blatt 2.1、VDI/VDE 2617 Blatt 2.2、VDI/VDE 2617 Blatt 4） 0 mm 至 3030 mm CMC (0,23·L + 0,06) µm KP001-ZEISS-10360, KP002-ZEISS-2617","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"002cb8a214ed804600cc8e2b","lab_id":"6ade8b4dff0682476170813a","country":"CZ","accr_number":"2398","accr_body":"ČIA","row_label":"2","test_object":"Współrzędnościowe maszyny pomiarowe Carl Zeiss z czujnikami tomografii komputerowej","test_object_en":"Carl Zeiss coordinate measuring machines with computed tomography sensors","test_object_zh":"带计算机断层扫描传感器的 Carl Zeiss 坐标测量机","test_object_cs":"Souřadnicové měřicí stroje Carl Zeiss se senzory počítačové tomografie","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"odległość środków kul U (SD)","range":"od 0 mm do 870 mm","cmc":"0,31 µm"},{"name":"średnica kuli U (PS)","range":"od 0 mm do 330 mm","cmc":"0,48 µm"},{"name":"odchyłka kształtu U (PF)","range":"od 0 mm do 3 mm","cmc":"0,44 µm"},{"name":"całkowity błąd długości U (EL)","range":"od 0 mm do 900 mm","cmc":"0,78 µm"}],"parameters_en":[{"name":"ball centre distance U (SD)","range":"0 mm to 870 mm","cmc":"0,31 µm"},{"name":"ball diameter U (PS)","range":"0 mm to 330 mm","cmc":"0,48 µm"},{"name":"shape deviation U (PF)","range":"0 mm to 3 mm","cmc":"0,44 µm"},{"name":"total length error U (EL)","range":"0 mm to 900 mm","cmc":"0,78 µm"}],"parameters_zh":[{"name":"球心距 U (SD)","range":"0 mm 至 870 mm","cmc":"0,31 µm"},{"name":"球直径 U (PS)","range":"0 mm 至 330 mm","cmc":"0,48 µm"},{"name":"形状偏差 U (PF)","range":"0 mm 至 3 mm","cmc":"0,44 µm"},{"name":"总长度误差 U (EL)","range":"0 mm 至 900 mm","cmc":"0,78 µm"}],"parameters_cs":[{"name":"vzdálenost středu koulí U (SD)","range":"0 mm až 870 mm","cmc":"0,31 µm"},{"name":"průměr koule U (PS)","range":"0 mm až 330 mm","cmc":"0,48 µm"},{"name":"odchylka tvaru U (PF)","range":"0 mm až 3 mm","cmc":"0,44 µm"},{"name":"celková délková chyba U (EL)","range":"0 mm až 900 mm","cmc":"0,78 µm"}],"technique":"Pomiar wzorca METROTOM Check (VDI/VDE 2630 Blatt 1.3)","technique_en":"Reference standard measurement METROTOM Check (VDI/VDE 2630 Blatt 1.3)","technique_zh":"测量 METROTOM Check 标准器（VDI/VDE 2630 Blatt 1.3）","technique_cs":"Měření etalonu METROTOM Check (VDI/VDE 2630 Blatt 1.3)","techniques":["Pomiar wzorca METROTOM Check (VDI/VDE 2630 Blatt 1.3)"],"techniques_en":["Reference standard measurement METROTOM Check (VDI/VDE 2630 Blatt 1.3)"],"techniques_zh":["测量 METROTOM Check 标准器（VDI/VDE 2630 Blatt 1.3）"],"techniques_cs":["Měření etalonu METROTOM Check (VDI/VDE 2630 Blatt 1.3)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nodległość środków kul U (SD) od 0 mm do 870 mm CMC 0,31 µm\nśrednica kuli U (PS) od 0 mm do 330 mm CMC 0,48 µm\nodchyłka kształtu U (PF) od 0 mm do 3 mm CMC 0,44 µm\ncałkowity błąd długości U (EL) od 0 mm do 900 mm CMC 0,78 µm\nPomiar wzorca METROTOM Check (VDI/VDE 2630 Blatt 1.3)","reference":"KP003-ZEISS-2630","norm_bases":["KP003-ZEISS-2630"],"lab_section":"Nupaky","lab_section_en":"Nupaky","lab_section_zh":"Nupaky 工作场所","lab_section_cs":"Nupaky","lab_address":"Komerční 524, Nupaky, 251 01 Praha - Východ","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Współrzędnościowe maszyny pomiarowe Carl Zeiss z czujnikami tomografii komputerowej Wzorcowanie – długość Pomiar wzorca METROTOM Check (VDI/VDE 2630 Blatt 1.3) odległość środków kul U (SD) od 0 mm do 870 mm CMC 0,31 µm średnica kuli U (PS) od 0 mm do 330 mm CMC 0,48 µm odchyłka kształtu U (PF) od 0 mm do 3 mm CMC 0,44 µm całkowity błąd długości U (EL) od 0 mm do 900 mm CMC 0,78 µm Souřadnicové měřicí stroje Carl Zeiss se senzory počítačové tomografie Kalibrace – délka Měření etalonu METROTOM Check (VDI/VDE 2630 Blatt 1.3) vzdálenost středu koulí U (SD) 0 mm až 870 mm CMC 0,31 µm průměr koule U (PS) 0 mm až 330 mm CMC 0,48 µm odchylka tvaru U (PF) 0 mm až 3 mm CMC 0,44 µm celková délková chyba U (EL) 0 mm až 900 mm CMC 0,78 µm KP003-ZEISS-2630 Wspolrzednosciowe maszyny pomiarowe Carl Zeiss z czujnikami tomografii komputerowej Wzorcowanie – dlugosc Pomiar wzorca METROTOM Check (VDI/VDE 2630 Blatt 1.3) odleglosc srodkow kul U (SD) od 0 mm do 870 mm CMC 0,31 µm srednica kuli U (PS) od 0 mm do 330 mm CMC 0,48 µm odchylka ksztaltu U (PF) od 0 mm do 3 mm CMC 0,44 µm calkowity blad dlugosci U (EL) od 0 mm do 900 mm CMC 0,78 µm Souradnicove merici stroje Carl Zeiss se senzory pocitacove tomografie Kalibrace – delka Mereni etalonu METROTOM Check (VDI/VDE 2630 Blatt 1.3) vzdalenost stredu kouli U (SD) 0 mm az 870 mm CMC 0,31 µm prumer koule U (PS) 0 mm az 330 mm CMC 0,48 µm odchylka tvaru U (PF) 0 mm az 3 mm CMC 0,44 µm celkova delkova chyba U (EL) 0 mm az 900 mm CMC 0,78 µm KP003-ZEISS-2630","search_en":"Carl Zeiss coordinate measuring machines with computed tomography sensors Calibration – length Reference standard measurement METROTOM Check (VDI/VDE 2630 Blatt 1.3) ball centre distance U (SD) 0 mm to 870 mm CMC 0,31 µm ball diameter U (PS) 0 mm to 330 mm CMC 0,48 µm shape deviation U (PF) 0 mm to 3 mm CMC 0,44 µm total length error U (EL) 0 mm to 900 mm CMC 0,78 µm KP003-ZEISS-2630","search_zh":"带计算机断层扫描传感器的 Carl Zeiss 坐标测量机 校准 – 长度 测量 METROTOM Check 标准器（VDI/VDE 2630 Blatt 1.3） 球心距 U (SD) 0 mm 至 870 mm CMC 0,31 µm 球直径 U (PS) 0 mm 至 330 mm CMC 0,48 µm 形状偏差 U (PF) 0 mm 至 3 mm CMC 0,44 µm 总长度误差 U (EL) 0 mm 至 900 mm CMC 0,78 µm KP003-ZEISS-2630","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ff30f8a44438c12e5b4c4207","lab_id":"6ade8b4dff0682476170813a","country":"CZ","accr_number":"2398","accr_body":"ČIA","row_label":"3","test_object":"Optyczne systemy 3D Carl Zeiss","test_object_en":"Carl Zeiss optical 3D systems","test_object_zh":"Carl Zeiss 光学 3D 系统","test_object_cs":"Optické 3D systémy Carl Zeiss","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"wyznaczanie odchyłki odległości środków kul U (SD)","range":"od 0 mm do 1000 mm","cmc":"0,16 µm"},{"name":"wyznaczanie odchyłki błędu długości U (E)","range":"od 0 mm do 1000 mm","cmc":"0,27 µm"},{"name":"wyznaczanie odchyłki próbkowania wymiaru U (PS)","range":"od 0 mm do 60 mm","cmc":"0,15 µm"},{"name":"wyznaczanie odchyłki próbkowania wymiaru U (PF)","range":"od 0 mm do 60 mm","cmc":"0,19 µm"}],"parameters_en":[{"name":"determination of ball centre distance deviation U (SD)","range":"0 mm to 1000 mm","cmc":"0,16 µm"},{"name":"determination of length error deviation U (E)","range":"0 mm to 1000 mm","cmc":"0,27 µm"},{"name":"determination of dimension measurement deviation U (PS)","range":"0 mm to 60 mm","cmc":"0,15 µm"},{"name":"determination of dimension measurement deviation U (PF)","range":"0 mm to 60 mm","cmc":"0,19 µm"}],"parameters_zh":[{"name":"球心距偏差的测定 U (SD)","range":"0 mm 至 1000 mm","cmc":"0,16 µm"},{"name":"长度误差偏差的测定 U (E)","range":"0 mm 至 1000 mm","cmc":"0,27 µm"},{"name":"尺寸探测偏差的测定 U (PS)","range":"0 mm 至 60 mm","cmc":"0,15 µm"},{"name":"尺寸探测偏差的测定 U (PF)","range":"0 mm 至 60 mm","cmc":"0,19 µm"}],"parameters_cs":[{"name":"stanovení odchylky vzdálenosti středu koulí U (SD)","range":"0 mm až 1000 mm","cmc":"0,16 µm"},{"name":"stanovení odchylky délkové chyby U (E)","range":"0 mm až 1000 mm","cmc":"0,27 µm"},{"name":"stanovení odchylky snímání rozměru U (PS)","range":"0 mm až 60 mm","cmc":"0,15 µm"},{"name":"stanovení odchylky snímání rozměru U (PF)","range":"0 mm až 60 mm","cmc":"0,19 µm"}],"technique":"Pomiar wzorca PSA (ISO 10360-13)","technique_en":"PSA reference standard measurement (ISO 10360-13)","technique_zh":"测量 PSA 标准器（ISO 10360-13）","technique_cs":"Měření etalonu PSA (ISO 10360-13)","techniques":["Pomiar wzorca PSA (ISO 10360-13)"],"techniques_en":["PSA reference standard measurement (ISO 10360-13)"],"techniques_zh":["测量 PSA 标准器（ISO 10360-13）"],"techniques_cs":["Měření etalonu PSA (ISO 10360-13)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nwyznaczanie odchyłki odległości środków kul U (SD) od 0 mm do 1000 mm CMC 0,16 µm\nwyznaczanie odchyłki błędu długości U (E) od 0 mm do 1000 mm CMC 0,27 µm\nwyznaczanie odchyłki próbkowania wymiaru U (PS) od 0 mm do 60 mm CMC 0,15 µm\nwyznaczanie odchyłki próbkowania wymiaru U (PF) od 0 mm do 60 mm CMC 0,19 µm\nPomiar wzorca PSA (ISO 10360-13)","reference":"KP004-ZEISS-10360","norm_bases":["KP004-ZEISS-10360"],"lab_section":"Nupaky","lab_section_en":"Nupaky","lab_section_zh":"Nupaky 工作场所","lab_section_cs":"Nupaky","lab_address":"Komerční 524, Nupaky, 251 01 Praha - Východ","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Optyczne systemy 3D Carl Zeiss Wzorcowanie – długość Pomiar wzorca PSA (ISO 10360-13) wyznaczanie odchyłki odległości środków kul U (SD) od 0 mm do 1000 mm CMC 0,16 µm wyznaczanie odchyłki błędu długości U (E) od 0 mm do 1000 mm CMC 0,27 µm wyznaczanie odchyłki próbkowania wymiaru U (PS) od 0 mm do 60 mm CMC 0,15 µm wyznaczanie odchyłki próbkowania wymiaru U (PF) od 0 mm do 60 mm CMC 0,19 µm Optické 3D systémy Carl Zeiss Kalibrace – délka Měření etalonu PSA (ISO 10360-13) stanovení odchylky vzdálenosti středu koulí U (SD) 0 mm až 1000 mm CMC 0,16 µm stanovení odchylky délkové chyby U (E) 0 mm až 1000 mm CMC 0,27 µm stanovení odchylky snímání rozměru U (PS) 0 mm až 60 mm CMC 0,15 µm stanovení odchylky snímání rozměru U (PF) 0 mm až 60 mm CMC 0,19 µm KP004-ZEISS-10360 Optyczne systemy 3D Carl Zeiss Wzorcowanie – dlugosc Pomiar wzorca PSA (ISO 10360-13) wyznaczanie odchylki odleglosci srodkow kul U (SD) od 0 mm do 1000 mm CMC 0,16 µm wyznaczanie odchylki bledu dlugosci U (E) od 0 mm do 1000 mm CMC 0,27 µm wyznaczanie odchylki probkowania wymiaru U (PS) od 0 mm do 60 mm CMC 0,15 µm wyznaczanie odchylki probkowania wymiaru U (PF) od 0 mm do 60 mm CMC 0,19 µm Opticke 3D systemy Carl Zeiss Kalibrace – delka Mereni etalonu PSA (ISO 10360-13) stanoveni odchylky vzdalenosti stredu kouli U (SD) 0 mm az 1000 mm CMC 0,16 µm stanoveni odchylky delkove chyby U (E) 0 mm az 1000 mm CMC 0,27 µm stanoveni odchylky snimani rozmeru U (PS) 0 mm az 60 mm CMC 0,15 µm stanoveni odchylky snimani rozmeru U (PF) 0 mm az 60 mm CMC 0,19 µm KP004-ZEISS-10360","search_en":"Carl Zeiss optical 3D systems Calibration – length PSA reference standard measurement (ISO 10360-13) determination of ball centre distance deviation U (SD) 0 mm to 1000 mm CMC 0,16 µm determination of length error deviation U (E) 0 mm to 1000 mm CMC 0,27 µm determination of dimension measurement deviation U (PS) 0 mm to 60 mm CMC 0,15 µm determination of dimension measurement deviation U (PF) 0 mm to 60 mm CMC 0,19 µm KP004-ZEISS-10360","search_zh":"Carl Zeiss 光学 3D 系统 校准 – 长度 测量 PSA 标准器（ISO 10360-13） 球心距偏差的测定 U (SD) 0 mm 至 1000 mm CMC 0,16 µm 长度误差偏差的测定 U (E) 0 mm 至 1000 mm CMC 0,27 µm 尺寸探测偏差的测定 U (PS) 0 mm 至 60 mm CMC 0,15 µm 尺寸探测偏差的测定 U (PF) 0 mm 至 60 mm CMC 0,19 µm KP004-ZEISS-10360","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}