{"lab":{"_id":"6ade8b4cff06824761708139","accr_number":"2397","country":"CZ","accr_body":"ČIA","address":"Boudníkova 2538/13, Libeň, 180 00 Praha 8","categories":["metrology"],"city":"Praha 8","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[14.4661085,50.1043377]},"map_coord":[50.1043377,14.4661085],"map_geo":"cai-mapa","methods_count":23,"name":"Hexagon Manufacturing Intelligence Czech Republic s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinie długości, w zakresie określonym w załączniku do świadectwa.","search_text":"hexagon manufacturing intelligence czech republic s.r.o. boudníkova 2538/13, libeň, 180 00 praha 8 2397","source_page_url":"https://www.cai.cz/?subjekt=2397-hexagon-manufacturing-intelligence-czech-republic-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"28-11-2030","website":"www.hexagon.com","certificate_date":"23.09.2026","certificate_no":"439/2026","certificate_replaces":"619/2025 z 28.11.2025","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinie długości, w zakresie określonym w załączniku do świadectwa.","en":"Calibration in the field of length to the extent as specified in the appendix to this Certificate.","zh":"长度领域的校准，范围见本证书附件。","cs":"Kalibrace v oboru délka, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące","lab_division_cs":"Kalibrační laboratoř","lab_division_en":"Calibration Laboratory","lab_division_zh":"校准实验室","lab_locations":[{"code":null,"name":"Hexagon Manufacturing Intelligence Czech Republic s.r.o.","street":"Boudníkova 2538/13, Libeň","postal_code":"180 00","city":"Praha 8","is_hq":true,"address":"Boudníkova 2538/13, Libeň, 180 00 Praha 8","site":"18000|boudníkova2538/13libeň"},{"code":null,"name":"Pracownia Praga","street":"Boudníkova 2538/13, Libeň","postal_code":"180 00","city":"Praha 8","is_hq":false,"address":"Boudníkova 2538/13, Libeň, 180 00 Praha 8","site":"18000|boudníkova2538/13libeň"},{"code":null,"name":"Pracownia Bratysława","street":"Tuhovská","postal_code":"831 06","city":"Bratislava – Vajnory","is_hq":false,"address":"Tuhovská, 831 06 Bratislava – Vajnory","site":"83106|tuhovská"},{"code":null,"name":"Pracownia Budapeszt","street":"Nagytétényi út 112","postal_code":"1222","city":"Budapest","is_hq":false,"address":"Nagytétényi út 112, 1222 Budapest","site":"1222|nagytétényiút112"}],"lab_locations_en":[{"code":null,"name":"Hexagon Manufacturing Intelligence Czech Republic s.r.o.","street":"Boudníkova 2538/13, Libeň","postal_code":"180 00","city":"Praha 8","is_hq":true,"address":"Boudníkova 2538/13, Libeň, 180 00 Praha 8","site":"18000|boudníkova2538/13libeň"},{"code":null,"name":"Workplace Prague","street":"Boudníkova 2538/13, Libeň","postal_code":"180 00","city":"Praha 8","is_hq":false,"address":"Boudníkova 2538/13, Libeň, 180 00 Praha 8","site":"18000|boudníkova2538/13libeň"},{"code":null,"name":"Workplace Bratislava","street":"Tuhovská","postal_code":"831 06","city":"Bratislava – Vajnory","is_hq":false,"address":"Tuhovská, 831 06 Bratislava – Vajnory","site":"83106|tuhovská"},{"code":null,"name":"Workplace Budapest","street":"Nagytétényi út 112","postal_code":"1222","city":"Budapest","is_hq":false,"address":"Nagytétényi út 112, 1222 Budapest","site":"1222|nagytétényiút112"}],"lab_locations_zh":[{"code":null,"name":"Hexagon Manufacturing Intelligence Czech Republic s.r.o.","street":"Boudníkova 2538/13, Libeň","postal_code":"180 00","city":"Praha 8","is_hq":true,"address":"Boudníkova 2538/13, Libeň, 180 00 Praha 8","site":"18000|boudníkova2538/13libeň"},{"code":null,"name":"布拉格工作场所","street":"Boudníkova 2538/13, Libeň","postal_code":"180 00","city":"Praha 8","is_hq":false,"address":"Boudníkova 2538/13, Libeň, 180 00 Praha 8","site":"18000|boudníkova2538/13libeň"},{"code":null,"name":"布拉迪斯拉发工作场所","street":"Tuhovská","postal_code":"831 06","city":"Bratislava – Vajnory","is_hq":false,"address":"Tuhovská, 831 06 Bratislava – Vajnory","site":"83106|tuhovská"},{"code":null,"name":"布达佩斯工作场所","street":"Nagytétényi út 112","postal_code":"1222","city":"Budapest","is_hq":false,"address":"Nagytétényi út 112, 1222 Budapest","site":"1222|nagytétényiút112"}],"parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"L","pl":"mierzona długość (m)","en":"measured length (m)","zh":"测量长度（m）","cs":"měřená délka (m)"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"b80de7aaa4549221d1a723e5ac76a3e458f01105b2263a36a03bb32038be9448","source_pdf_url":"https://www.cai.cz/OA/pdf/439_2026_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/439_2026_EN.pdf"},"methods":[{"_id":"7c2111b38c4a77d160ba2858","lab_id":"6ade8b4cff06824761708139","country":"CZ","accr_number":"2397","accr_body":"ČIA","row_label":"1","test_object":"Współrzędnościowe maszyny pomiarowe","test_object_en":"Coordinate measuring machines","test_object_zh":"坐标测量机","test_object_cs":"Souřadnicové měřicí stroje","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"Długość przestrzenna","range":"od 0 m do 6 m","cmc":"(0,25·L + 0,25) µm"}],"parameters_en":[{"name":"Spatial length","range":"0 m to 6 m","cmc":"(0,25·L + 0,25) µm"}],"parameters_zh":[{"name":"空间长度","range":"0 m 至 6 m","cmc":"(0,25·L + 0,25) µm"}],"parameters_cs":[{"name":"Prostorová délka","range":"0 m až 6 m","cmc":"(0,25·L + 0,25) µm"}],"technique":"Pomiar płytkami wzorcowymi i wzorcem schodkowym","technique_en":"Measurement with parallel gauge blocks and step gauge","technique_zh":"用量块和阶梯规测量","technique_cs":"Měření koncovými měrkami a stupňovou měrkou","techniques":["Pomiar płytkami wzorcowymi i wzorcem schodkowym"],"techniques_en":["Measurement with parallel gauge blocks and step gauge"],"techniques_zh":["用量块和阶梯规测量"],"techniques_cs":["Měření koncovými měrkami a stupňovou měrkou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nDługość przestrzenna od 0 m do 6 m CMC (0,25·L + 0,25) µm\nPomiar płytkami wzorcowymi i wzorcem schodkowym","reference":"KP1 – SMS1","norm_bases":["KP1 – SMS1"],"lab_section":"Pracownia Praga","lab_section_en":"Workplace Prague","lab_section_zh":"布拉格工作场所","lab_section_cs":"Pracoviště Praha","lab_address":"Boudníkova 2538/13, Libeň, 180 00 Praha 8","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Współrzędnościowe maszyny pomiarowe Wzorcowanie – długość Pomiar płytkami wzorcowymi i wzorcem schodkowym Długość przestrzenna od 0 m do 6 m CMC (0,25·L + 0,25) µm Souřadnicové měřicí stroje Kalibrace – délka Měření koncovými měrkami a stupňovou měrkou Prostorová délka 0 m až 6 m CMC (0,25·L + 0,25) µm KP1 – SMS1 Wspolrzednosciowe maszyny pomiarowe Wzorcowanie – dlugosc Pomiar plytkami wzorcowymi i wzorcem schodkowym Dlugosc przestrzenna od 0 m do 6 m CMC (0,25·L + 0,25) µm Souradnicove merici stroje Kalibrace – delka Mereni koncovymi merkami a stupnovou merkou Prostorova delka 0 m az 6 m CMC (0,25·L + 0,25) µm KP1 – SMS1","search_en":"Coordinate measuring machines Calibration – length Measurement with parallel gauge blocks and step gauge Spatial length 0 m to 6 m CMC (0,25·L + 0,25) µm KP1 – SMS1","search_zh":"坐标测量机 校准 – 长度 用量块和阶梯规测量 空间长度 0 m 至 6 m CMC (0,25·L + 0,25) µm KP1 – SMS1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1c554b168bc0c11bec982c78","lab_id":"6ade8b4cff06824761708139","country":"CZ","accr_number":"2397","accr_body":"ČIA","row_label":"1","test_object":"Współrzędnościowe maszyny pomiarowe","test_object_en":"Coordinate measuring machines","test_object_zh":"坐标测量机","test_object_cs":"Souřadnicové měřicí stroje","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"Błąd układu próbkującego","range":"od 0 mm do 1 mm","cmc":"0,1 µm"}],"parameters_en":[{"name":"Sensing system error","range":"0 mm to 1 mm","cmc":"0,1 µm"}],"parameters_zh":[{"name":"探测系统误差","range":"0 mm 至 1 mm","cmc":"0,1 µm"}],"parameters_cs":[{"name":"Chyba snímacího systému","range":"0 mm až 1 mm","cmc":"0,1 µm"}],"technique":"Pomiar za pomocą kuli wzorcowej","technique_en":"Measurement using a calibration ball","technique_zh":"用校准球测量","technique_cs":"Měření pomocí kalibrační koule","techniques":["Pomiar za pomocą kuli wzorcowej"],"techniques_en":["Measurement using a calibration ball"],"techniques_zh":["用校准球测量"],"techniques_cs":["Měření pomocí kalibrační koule"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nBłąd układu próbkującego od 0 mm do 1 mm CMC 0,1 µm\nPomiar za pomocą kuli wzorcowej","reference":"KP1 – SMS1","norm_bases":["KP1 – SMS1"],"lab_section":"Pracownia Praga","lab_section_en":"Workplace Prague","lab_section_zh":"布拉格工作场所","lab_section_cs":"Pracoviště Praha","lab_address":"Boudníkova 2538/13, Libeň, 180 00 Praha 8","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Współrzędnościowe maszyny pomiarowe Wzorcowanie – długość Pomiar za pomocą kuli wzorcowej Błąd układu próbkującego od 0 mm do 1 mm CMC 0,1 µm Souřadnicové měřicí stroje Kalibrace – délka Měření pomocí kalibrační koule Chyba snímacího systému 0 mm až 1 mm CMC 0,1 µm KP1 – SMS1 Wspolrzednosciowe maszyny pomiarowe Wzorcowanie – dlugosc Pomiar za pomoca kuli wzorcowej Blad ukladu probkujacego od 0 mm do 1 mm CMC 0,1 µm Souradnicove merici stroje Kalibrace – delka Mereni pomoci kalibracni koule Chyba snimaciho systemu 0 mm az 1 mm CMC 0,1 µm KP1 – SMS1","search_en":"Coordinate measuring machines Calibration – length Measurement using a calibration ball Sensing system error 0 mm to 1 mm CMC 0,1 µm KP1 – SMS1","search_zh":"坐标测量机 校准 – 长度 用校准球测量 探测系统误差 0 mm 至 1 mm CMC 0,1 µm KP1 – SMS1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b75f0a08c1782e269e1741fc","lab_id":"6ade8b4cff06824761708139","country":"CZ","accr_number":"2397","accr_body":"ČIA","row_label":"1","test_object":"Współrzędnościowe maszyny pomiarowe","test_object_en":"Coordinate measuring machines","test_object_zh":"坐标测量机","test_object_cs":"Souřadnicové měřicí stroje","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"Długość przestrzenna","range":"od 0 m do 30 m","cmc":"(0,5·L + 0,06) µm"}],"parameters_en":[{"name":"Spatial length","range":"0 m to 30 m","cmc":"(0,5·L + 0,06) µm"}],"parameters_zh":[{"name":"空间长度","range":"0 m 至 30 m","cmc":"(0,5·L + 0,06) µm"}],"parameters_cs":[{"name":"Prostorová délka","range":"0 m až 30 m","cmc":"(0,5·L + 0,06) µm"}],"technique":"Pomiar interferometrem laserowym","technique_en":"Laser interferometer measurements","technique_zh":"用激光干涉仪测量","technique_cs":"Měření laserovým interferometrem","techniques":["Pomiar interferometrem laserowym"],"techniques_en":["Laser interferometer measurements"],"techniques_zh":["用激光干涉仪测量"],"techniques_cs":["Měření laserovým interferometrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nDługość przestrzenna od 0 m do 30 m CMC (0,5·L + 0,06) µm\nPomiar interferometrem laserowym","reference":"KP2 – SMS2","norm_bases":["KP2 – SMS2"],"lab_section":"Pracownia Praga","lab_section_en":"Workplace Prague","lab_section_zh":"布拉格工作场所","lab_section_cs":"Pracoviště Praha","lab_address":"Boudníkova 2538/13, Libeň, 180 00 Praha 8","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Współrzędnościowe maszyny pomiarowe Wzorcowanie – długość Pomiar interferometrem laserowym Długość przestrzenna od 0 m do 30 m CMC (0,5·L + 0,06) µm Souřadnicové měřicí stroje Kalibrace – délka Měření laserovým interferometrem Prostorová délka 0 m až 30 m CMC (0,5·L + 0,06) µm KP2 – SMS2 Wspolrzednosciowe maszyny pomiarowe Wzorcowanie – dlugosc Pomiar interferometrem laserowym Dlugosc przestrzenna od 0 m do 30 m CMC (0,5·L + 0,06) µm Souradnicove merici stroje Kalibrace – delka Mereni laserovym interferometrem Prostorova delka 0 m az 30 m CMC (0,5·L + 0,06) µm KP2 – SMS2","search_en":"Coordinate measuring machines Calibration – length Laser interferometer measurements Spatial length 0 m to 30 m CMC (0,5·L + 0,06) µm KP2 – SMS2","search_zh":"坐标测量机 校准 – 长度 用激光干涉仪测量 空间长度 0 m 至 30 m CMC (0,5·L + 0,06) µm KP2 – SMS2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f267c445b99a3ebfd68531ae","lab_id":"6ade8b4cff06824761708139","country":"CZ","accr_number":"2397","accr_body":"ČIA","row_label":"1","test_object":"Współrzędnościowe maszyny pomiarowe","test_object_en":"Coordinate measuring machines","test_object_zh":"坐标测量机","test_object_cs":"Souřadnicové měřicí stroje","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"Błąd układu próbkującego","range":"od 0 mm do 1 mm","cmc":"0,1 µm"}],"parameters_en":[{"name":"Sensing system error","range":"0 mm to 1 mm","cmc":"0,1 µm"}],"parameters_zh":[{"name":"探测系统误差","range":"0 mm 至 1 mm","cmc":"0,1 µm"}],"parameters_cs":[{"name":"Chyba snímacího systému","range":"0 mm až 1 mm","cmc":"0,1 µm"}],"technique":"Pomiar za pomocą kuli wzorcowej","technique_en":"Measurement using a calibration ball","technique_zh":"用校准球测量","technique_cs":"Měření pomocí kalibrační koule","techniques":["Pomiar za pomocą kuli wzorcowej"],"techniques_en":["Measurement using a calibration ball"],"techniques_zh":["用校准球测量"],"techniques_cs":["Měření pomocí kalibrační koule"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nBłąd układu próbkującego od 0 mm do 1 mm CMC 0,1 µm\nPomiar za pomocą kuli wzorcowej","reference":"KP2 – SMS2","norm_bases":["KP2 – SMS2"],"lab_section":"Pracownia Praga","lab_section_en":"Workplace Prague","lab_section_zh":"布拉格工作场所","lab_section_cs":"Pracoviště Praha","lab_address":"Boudníkova 2538/13, Libeň, 180 00 Praha 8","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Współrzędnościowe maszyny pomiarowe Wzorcowanie – długość Pomiar za pomocą kuli wzorcowej Błąd układu próbkującego od 0 mm do 1 mm CMC 0,1 µm Souřadnicové měřicí stroje Kalibrace – délka Měření pomocí kalibrační koule Chyba snímacího systému 0 mm až 1 mm CMC 0,1 µm KP2 – SMS2 Wspolrzednosciowe maszyny pomiarowe Wzorcowanie – dlugosc Pomiar za pomoca kuli wzorcowej Blad ukladu probkujacego od 0 mm do 1 mm CMC 0,1 µm Souradnicove merici stroje Kalibrace – delka Mereni pomoci kalibracni koule Chyba snimaciho systemu 0 mm az 1 mm CMC 0,1 µm KP2 – SMS2","search_en":"Coordinate measuring machines Calibration – length Measurement using a calibration ball Sensing system error 0 mm to 1 mm CMC 0,1 µm KP2 – SMS2","search_zh":"坐标测量机 校准 – 长度 用校准球测量 探测系统误差 0 mm 至 1 mm CMC 0,1 µm KP2 – SMS2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"54b305ded3192f55732c49d0","lab_id":"6ade8b4cff06824761708139","country":"CZ","accr_number":"2397","accr_body":"ČIA","row_label":"1","test_object":"Współrzędnościowe maszyny pomiarowe z czujnikiem laserowym","test_object_en":"Coordinate measuring machines with a laser sensor","test_object_zh":"带激光传感器的坐标测量机","test_object_cs":"Souřadnicové měřicí stroje s laserovým sensorem","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"Próbkowanie wymiaru","range":"od 10 mm do 50 mm","cmc":"1,9 µm"}],"parameters_en":[{"name":"Dimension sensing","range":"10 mm to 50 mm","cmc":"1,9 µm"}],"parameters_zh":[{"name":"尺寸探测","range":"10 mm 至 50 mm","cmc":"1,9 µm"}],"parameters_cs":[{"name":"Snímání rozměru","range":"10 mm až 50 mm","cmc":"1,9 µm"}],"technique":"Pomiar za pomocą kuli wzorcowej","technique_en":"Measurement using a calibration ball","technique_zh":"用校准球测量","technique_cs":"Měření pomocí kalibrační koule","techniques":["Pomiar za pomocą kuli wzorcowej"],"techniques_en":["Measurement using a calibration ball"],"techniques_zh":["用校准球测量"],"techniques_cs":["Měření pomocí kalibrační koule"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nPróbkowanie wymiaru od 10 mm do 50 mm CMC 1,9 µm\nPomiar za pomocą kuli wzorcowej","reference":"KP5 – LASER","norm_bases":["KP5 – LASER"],"lab_section":"Pracownia Praga","lab_section_en":"Workplace Prague","lab_section_zh":"布拉格工作场所","lab_section_cs":"Pracoviště Praha","lab_address":"Boudníkova 2538/13, Libeň, 180 00 Praha 8","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Współrzędnościowe maszyny pomiarowe z czujnikiem laserowym Wzorcowanie – długość Pomiar za pomocą kuli wzorcowej Próbkowanie wymiaru od 10 mm do 50 mm CMC 1,9 µm Souřadnicové měřicí stroje s laserovým sensorem Kalibrace – délka Měření pomocí kalibrační koule Snímání rozměru 10 mm až 50 mm CMC 1,9 µm KP5 – LASER Wspolrzednosciowe maszyny pomiarowe z czujnikiem laserowym Wzorcowanie – dlugosc Pomiar za pomoca kuli wzorcowej Probkowanie wymiaru od 10 mm do 50 mm CMC 1,9 µm Souradnicove merici stroje s laserovym sensorem Kalibrace – delka Mereni pomoci kalibracni koule Snimani rozmeru 10 mm az 50 mm CMC 1,9 µm KP5 – LASER","search_en":"Coordinate measuring machines with a laser sensor Calibration – length Measurement using a calibration ball Dimension sensing 10 mm to 50 mm CMC 1,9 µm KP5 – LASER","search_zh":"带激光传感器的坐标测量机 校准 – 长度 用校准球测量 尺寸探测 10 mm 至 50 mm CMC 1,9 µm KP5 – LASER","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9ca5b1994079a8a943b59e87","lab_id":"6ade8b4cff06824761708139","country":"CZ","accr_number":"2397","accr_body":"ČIA","row_label":"1","test_object":"Współrzędnościowe maszyny pomiarowe z czujnikiem laserowym","test_object_en":"Coordinate measuring machines with a laser sensor","test_object_zh":"带激光传感器的坐标测量机","test_object_cs":"Souřadnicové měřicí stroje s laserovým sensorem","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"Próbkowanie kształtu i rozrzut próbkowania","range":"od 0 mm do 1 mm","cmc":"2,0 µm"}],"parameters_en":[{"name":"Sensing of shape and scatter of sensing","range":"0 mm to 1 mm","cmc":"2,0 µm"}],"parameters_zh":[{"name":"形状探测及探测离散度","range":"0 mm 至 1 mm","cmc":"2,0 µm"}],"parameters_cs":[{"name":"Snímání tvaru a rozptyl snímání","range":"0 mm až 1 mm","cmc":"2,0 µm"}],"technique":"Pomiar wzorcową białą płytą","technique_en":"Measurement using white plate standard","technique_zh":"用标准白板测量","technique_cs":"Měření etalonovou bílou deskou","techniques":["Pomiar wzorcową białą płytą"],"techniques_en":["Measurement using white plate standard"],"techniques_zh":["用标准白板测量"],"techniques_cs":["Měření etalonovou bílou deskou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nPróbkowanie kształtu i rozrzut próbkowania od 0 mm do 1 mm CMC 2,0 µm\nPomiar wzorcową białą płytą","reference":"KP5 – LASER","norm_bases":["KP5 – LASER"],"lab_section":"Pracownia Praga","lab_section_en":"Workplace Prague","lab_section_zh":"布拉格工作场所","lab_section_cs":"Pracoviště Praha","lab_address":"Boudníkova 2538/13, Libeň, 180 00 Praha 8","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Współrzędnościowe maszyny pomiarowe z czujnikiem laserowym Wzorcowanie – długość Pomiar wzorcową białą płytą Próbkowanie kształtu i rozrzut próbkowania od 0 mm do 1 mm CMC 2,0 µm Souřadnicové měřicí stroje s laserovým sensorem Kalibrace – délka Měření etalonovou bílou deskou Snímání tvaru a rozptyl snímání 0 mm až 1 mm CMC 2,0 µm KP5 – LASER Wspolrzednosciowe maszyny pomiarowe z czujnikiem laserowym Wzorcowanie – dlugosc Pomiar wzorcowa biala plyta Probkowanie ksztaltu i rozrzut probkowania od 0 mm do 1 mm CMC 2,0 µm Souradnicove merici stroje s laserovym sensorem Kalibrace – delka Mereni etalonovou bilou deskou Snimani tvaru a rozptyl snimani 0 mm az 1 mm CMC 2,0 µm KP5 – LASER","search_en":"Coordinate measuring machines with a laser sensor Calibration – length Measurement using white plate standard Sensing of shape and scatter of sensing 0 mm to 1 mm CMC 2,0 µm KP5 – LASER","search_zh":"带激光传感器的坐标测量机 校准 – 长度 用标准白板测量 形状探测及探测离散度 0 mm 至 1 mm CMC 2,0 µm KP5 – LASER","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"95b8f5f0123c3b3943c498e9","lab_id":"6ade8b4cff06824761708139","country":"CZ","accr_number":"2397","accr_body":"ČIA","row_label":"2","test_object":"Optyczne maszyny pomiarowe z multisensorem","test_object_en":"Optical measuring machines with a multisensor","test_object_zh":"带多传感器的光学测量机","test_object_cs":"Optické měřicí stroje s multisenzorem","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"Długość przestrzenna","range":"od 0 mm do 600 mm","cmc":"(1,1·L + 0,3) µm"}],"parameters_en":[{"name":"Spatial length","range":"0 mm to 600 mm","cmc":"(1,1·L + 0,3) µm"}],"parameters_zh":[{"name":"空间长度","range":"0 mm 至 600 mm","cmc":"(1,1·L + 0,3) µm"}],"parameters_cs":[{"name":"Prostorová délka","range":"0 mm až 600 mm","cmc":"(1,1·L + 0,3) µm"}],"technique":"Pomiar płytkami wzorcowymi","technique_en":"Measurement with parallel gauge blocks","technique_zh":"用量块测量","technique_cs":"Měření koncovými měrkami","techniques":["Pomiar płytkami wzorcowymi"],"techniques_en":["Measurement with parallel gauge blocks"],"techniques_zh":["用量块测量"],"techniques_cs":["Měření koncovými měrkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nDługość przestrzenna od 0 mm do 600 mm CMC (1,1·L + 0,3) µm\nPomiar płytkami wzorcowymi","reference":"KP3 – OPTIKA","norm_bases":["KP3 – OPTIKA"],"lab_section":"Pracownia Praga","lab_section_en":"Workplace Prague","lab_section_zh":"布拉格工作场所","lab_section_cs":"Pracoviště Praha","lab_address":"Boudníkova 2538/13, Libeň, 180 00 Praha 8","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Optyczne maszyny pomiarowe z multisensorem Wzorcowanie – długość Pomiar płytkami wzorcowymi Długość przestrzenna od 0 mm do 600 mm CMC (1,1·L + 0,3) µm Optické měřicí stroje s multisenzorem Kalibrace – délka Měření koncovými měrkami Prostorová délka 0 mm až 600 mm CMC (1,1·L + 0,3) µm KP3 – OPTIKA Optyczne maszyny pomiarowe z multisensorem Wzorcowanie – dlugosc Pomiar plytkami wzorcowymi Dlugosc przestrzenna od 0 mm do 600 mm CMC (1,1·L + 0,3) µm Opticke merici stroje s multisenzorem Kalibrace – delka Mereni koncovymi merkami Prostorova delka 0 mm az 600 mm CMC (1,1·L + 0,3) µm KP3 – OPTIKA","search_en":"Optical measuring machines with a multisensor Calibration – length Measurement with parallel gauge blocks Spatial length 0 mm to 600 mm CMC (1,1·L + 0,3) µm KP3 – OPTIKA","search_zh":"带多传感器的光学测量机 校准 – 长度 用量块测量 空间长度 0 mm 至 600 mm CMC (1,1·L + 0,3) µm KP3 – OPTIKA","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f888ea742164057ba0361fa8","lab_id":"6ade8b4cff06824761708139","country":"CZ","accr_number":"2397","accr_body":"ČIA","row_label":"2","test_object":"Optyczne maszyny pomiarowe z multisensorem","test_object_en":"Optical measuring machines with a multisensor","test_object_zh":"带多传感器的光学测量机","test_object_cs":"Optické měřicí stroje s multisenzorem","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"Długość przestrzenna","range":"od 0 mm do 600 mm","cmc":"(0,2·L + 0,2) µm"}],"parameters_en":[{"name":"Spatial length","range":"0 mm to 600 mm","cmc":"(0,2·L + 0,2) µm"}],"parameters_zh":[{"name":"空间长度","range":"0 mm 至 600 mm","cmc":"(0,2·L + 0,2) µm"}],"parameters_cs":[{"name":"Prostorová délka","range":"0 mm až 600 mm","cmc":"(0,2·L + 0,2) µm"}],"technique":"Pomiar liniałem szklanym","technique_en":"Glass ruler measurement","technique_zh":"用玻璃尺测量","technique_cs":"Měření skleněným pravítkem","techniques":["Pomiar liniałem szklanym"],"techniques_en":["Glass ruler measurement"],"techniques_zh":["用玻璃尺测量"],"techniques_cs":["Měření skleněným pravítkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nDługość przestrzenna od 0 mm do 600 mm CMC (0,2·L + 0,2) µm\nPomiar liniałem szklanym","reference":"KP3 – OPTIKA","norm_bases":["KP3 – OPTIKA"],"lab_section":"Pracownia Praga","lab_section_en":"Workplace Prague","lab_section_zh":"布拉格工作场所","lab_section_cs":"Pracoviště Praha","lab_address":"Boudníkova 2538/13, Libeň, 180 00 Praha 8","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Optyczne maszyny pomiarowe z multisensorem Wzorcowanie – długość Pomiar liniałem szklanym Długość przestrzenna od 0 mm do 600 mm CMC (0,2·L + 0,2) µm Optické měřicí stroje s multisenzorem Kalibrace – délka Měření skleněným pravítkem Prostorová délka 0 mm až 600 mm CMC (0,2·L + 0,2) µm KP3 – OPTIKA Optyczne maszyny pomiarowe z multisensorem Wzorcowanie – dlugosc Pomiar linialem szklanym Dlugosc przestrzenna od 0 mm do 600 mm CMC (0,2·L + 0,2) µm Opticke merici stroje s multisenzorem Kalibrace – delka Mereni sklenenym pravitkem Prostorova delka 0 mm az 600 mm CMC (0,2·L + 0,2) µm KP3 – OPTIKA","search_en":"Optical measuring machines with a multisensor Calibration – length Glass ruler measurement Spatial length 0 mm to 600 mm CMC (0,2·L + 0,2) µm KP3 – OPTIKA","search_zh":"带多传感器的光学测量机 校准 – 长度 用玻璃尺测量 空间长度 0 mm 至 600 mm CMC (0,2·L + 0,2) µm KP3 – OPTIKA","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dc0b9cf9b5387bce37ce8705","lab_id":"6ade8b4cff06824761708139","country":"CZ","accr_number":"2397","accr_body":"ČIA","row_label":"2","test_object":"Optyczne maszyny pomiarowe z multisensorem","test_object_en":"Optical measuring machines with a multisensor","test_object_zh":"带多传感器的光学测量机","test_object_cs":"Optické měřicí stroje s multisenzorem","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"Błąd układu próbkującego","range":"od 0 mm do 1 mm","cmc":"0,1 µm"}],"parameters_en":[{"name":"Sensing system error","range":"0 mm to 1 mm","cmc":"0,1 µm"}],"parameters_zh":[{"name":"探测系统误差","range":"0 mm 至 1 mm","cmc":"0,1 µm"}],"parameters_cs":[{"name":"Chyba snímacího systému","range":"0 mm až 1 mm","cmc":"0,1 µm"}],"technique":"Pomiar za pomocą kuli wzorcowej","technique_en":"Measurement using a calibration ball","technique_zh":"用校准球测量","technique_cs":"Měření pomocí kalibrační koule","techniques":["Pomiar za pomocą kuli wzorcowej"],"techniques_en":["Measurement using a calibration ball"],"techniques_zh":["用校准球测量"],"techniques_cs":["Měření pomocí kalibrační koule"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nBłąd układu próbkującego od 0 mm do 1 mm CMC 0,1 µm\nPomiar za pomocą kuli wzorcowej","reference":"KP3 – OPTIKA","norm_bases":["KP3 – OPTIKA"],"lab_section":"Pracownia Praga","lab_section_en":"Workplace Prague","lab_section_zh":"布拉格工作场所","lab_section_cs":"Pracoviště Praha","lab_address":"Boudníkova 2538/13, Libeň, 180 00 Praha 8","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Optyczne maszyny pomiarowe z multisensorem Wzorcowanie – długość Pomiar za pomocą kuli wzorcowej Błąd układu próbkującego od 0 mm do 1 mm CMC 0,1 µm Optické měřicí stroje s multisenzorem Kalibrace – délka Měření pomocí kalibrační koule Chyba snímacího systému 0 mm až 1 mm CMC 0,1 µm KP3 – OPTIKA Optyczne maszyny pomiarowe z multisensorem Wzorcowanie – dlugosc Pomiar za pomoca kuli wzorcowej Blad ukladu probkujacego od 0 mm do 1 mm CMC 0,1 µm Opticke merici stroje s multisenzorem Kalibrace – delka Mereni pomoci kalibracni koule Chyba snimaciho systemu 0 mm az 1 mm CMC 0,1 µm KP3 – OPTIKA","search_en":"Optical measuring machines with a multisensor Calibration – length Measurement using a calibration ball Sensing system error 0 mm to 1 mm CMC 0,1 µm KP3 – OPTIKA","search_zh":"带多传感器的光学测量机 校准 – 长度 用校准球测量 探测系统误差 0 mm 至 1 mm CMC 0,1 µm KP3 – OPTIKA","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c5ba3d01430dfd777509e47c","lab_id":"6ade8b4cff06824761708139","country":"CZ","accr_number":"2397","accr_body":"ČIA","row_label":"3","test_object":"Ramiona pomiarowe","test_object_en":"Measuring arms","test_object_zh":"测量臂","test_object_cs":"Měřicí ramena","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"Długość przestrzenna","range":"od 0 m do 4,5 m","cmc":"(2,1·L + 1,2) µm"}],"parameters_en":[{"name":"Spatial length","range":"0 m to 4,5 m","cmc":"(2,1·L + 1,2) µm"}],"parameters_zh":[{"name":"空间长度","range":"0 m 至 4,5 m","cmc":"(2,1·L + 1,2) µm"}],"parameters_cs":[{"name":"Prostorová délka","range":"0 m až 4,5 m","cmc":"(2,1·L + 1,2) µm"}],"technique":"Pomiar wzorcem schodkowym","technique_en":"Measurement using a step gauge","technique_zh":"用阶梯规测量","technique_cs":"Měření stupňovou měrkou","techniques":["Pomiar wzorcem schodkowym"],"techniques_en":["Measurement using a step gauge"],"techniques_zh":["用阶梯规测量"],"techniques_cs":["Měření stupňovou měrkou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nDługość przestrzenna od 0 m do 4,5 m CMC (2,1·L + 1,2) µm\nPomiar wzorcem schodkowym","reference":"KP4 – RAMENA; ČSN EN ISO 10360-12; STN EN ISO 10360-12; MSZ EN ISO 10360-12; EN ISO 10360-12","norm_bases":["KP4 – RAMENA","ČSN EN ISO 10360-12","STN EN ISO 10360-12","MSZ EN ISO 10360-12","EN ISO 10360-12"],"lab_section":"Pracownia Praga","lab_section_en":"Workplace Prague","lab_section_zh":"布拉格工作场所","lab_section_cs":"Pracoviště Praha","lab_address":"Boudníkova 2538/13, Libeň, 180 00 Praha 8","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ramiona pomiarowe Wzorcowanie – długość Pomiar wzorcem schodkowym Długość przestrzenna od 0 m do 4,5 m CMC (2,1·L + 1,2) µm Měřicí ramena Kalibrace – délka Měření stupňovou měrkou Prostorová délka 0 m až 4,5 m CMC (2,1·L + 1,2) µm KP4 – RAMENA; ČSN EN ISO 10360-12; STN EN ISO 10360-12; MSZ EN ISO 10360-12; EN ISO 10360-12 Ramiona pomiarowe Wzorcowanie – dlugosc Pomiar wzorcem schodkowym Dlugosc przestrzenna od 0 m do 4,5 m CMC (2,1·L + 1,2) µm Merici ramena Kalibrace – delka Mereni stupnovou merkou Prostorova delka 0 m az 4,5 m CMC (2,1·L + 1,2) µm KP4 – RAMENA; CSN EN ISO 10360-12; STN EN ISO 10360-12; MSZ EN ISO 10360-12; EN ISO 10360-12","search_en":"Measuring arms Calibration – length Measurement using a step gauge Spatial length 0 m to 4,5 m CMC (2,1·L + 1,2) µm KP4 – RAMENA; ČSN EN ISO 10360-12; STN EN ISO 10360-12; MSZ EN ISO 10360-12; EN ISO 10360-12","search_zh":"测量臂 校准 – 长度 用阶梯规测量 空间长度 0 m 至 4,5 m CMC (2,1·L + 1,2) µm KP4 – RAMENA; ČSN EN ISO 10360-12; STN EN ISO 10360-12; MSZ EN ISO 10360-12; EN ISO 10360-12","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"aec53e1b96ea48cd05c273e2","lab_id":"6ade8b4cff06824761708139","country":"CZ","accr_number":"2397","accr_body":"ČIA","row_label":"3","test_object":"Ramiona pomiarowe","test_object_en":"Measuring arms","test_object_zh":"测量臂","test_object_cs":"Měřicí ramena","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"Długość przestrzenna","range":"od 0 m do 4,5 m","cmc":"(2,1·L + 1,2) µm"}],"parameters_en":[{"name":"Spatial length","range":"0 m to 4,5 m","cmc":"(2,1·L + 1,2) µm"}],"parameters_zh":[{"name":"空间长度","range":"0 m 至 4,5 m","cmc":"(2,1·L + 1,2) µm"}],"parameters_cs":[{"name":"Prostorová délka","range":"0 m až 4,5 m","cmc":"(2,1·L + 1,2) µm"}],"technique":"Pomiar wzorcem schodkowym","technique_en":"Measurement using a step gauge","technique_zh":"用阶梯规测量","technique_cs":"Měření stupňovou měrkou","techniques":["Pomiar wzorcem schodkowym"],"techniques_en":["Measurement using a step gauge"],"techniques_zh":["用阶梯规测量"],"techniques_cs":["Měření stupňovou měrkou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nDługość przestrzenna od 0 m do 4,5 m CMC (2,1·L + 1,2) µm\nPomiar wzorcem schodkowym","reference":"KP4 – RAMENA; ČSN EN ISO 10360-12; STN EN ISO 10360-12; MSZ EN ISO 10360-12; EN ISO 10360-12","norm_bases":["KP4 – RAMENA","ČSN EN ISO 10360-12","STN EN ISO 10360-12","MSZ EN ISO 10360-12","EN ISO 10360-12"],"lab_section":"Pracownia Bratysława","lab_section_en":"Workplace Bratislava","lab_section_zh":"布拉迪斯拉发工作场所","lab_section_cs":"Pracoviště Bratislava","lab_address":"Tuhovská 10722/29, 831 06 Bratislava – Vajnory","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ramiona pomiarowe Wzorcowanie – długość Pomiar wzorcem schodkowym Długość przestrzenna od 0 m do 4,5 m CMC (2,1·L + 1,2) µm Měřicí ramena Kalibrace – délka Měření stupňovou měrkou Prostorová délka 0 m až 4,5 m CMC (2,1·L + 1,2) µm KP4 – RAMENA; ČSN EN ISO 10360-12; STN EN ISO 10360-12; MSZ EN ISO 10360-12; EN ISO 10360-12 Ramiona pomiarowe Wzorcowanie – dlugosc Pomiar wzorcem schodkowym Dlugosc przestrzenna od 0 m do 4,5 m CMC (2,1·L + 1,2) µm Merici ramena Kalibrace – delka Mereni stupnovou merkou Prostorova delka 0 m az 4,5 m CMC (2,1·L + 1,2) µm KP4 – RAMENA; CSN EN ISO 10360-12; STN EN ISO 10360-12; MSZ EN ISO 10360-12; EN ISO 10360-12","search_en":"Measuring arms Calibration – length Measurement using a step gauge Spatial length 0 m to 4,5 m CMC (2,1·L + 1,2) µm KP4 – RAMENA; ČSN EN ISO 10360-12; STN EN ISO 10360-12; MSZ EN ISO 10360-12; EN ISO 10360-12","search_zh":"测量臂 校准 – 长度 用阶梯规测量 空间长度 0 m 至 4,5 m CMC (2,1·L + 1,2) µm KP4 – RAMENA; ČSN EN ISO 10360-12; STN EN ISO 10360-12; MSZ EN ISO 10360-12; EN ISO 10360-12","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1a1f10666d41f54bca92dfcd","lab_id":"6ade8b4cff06824761708139","country":"CZ","accr_number":"2397","accr_body":"ČIA","row_label":"3","test_object":"Ramiona pomiarowe","test_object_en":"Measuring arms","test_object_zh":"测量臂","test_object_cs":"Měřicí ramena","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"Długość przestrzenna","range":"od 0 m do 4,5 m","cmc":"(2,1·L + 1,2) µm"}],"parameters_en":[{"name":"Spatial length","range":"0 m to 4,5 m","cmc":"(2,1·L + 1,2) µm"}],"parameters_zh":[{"name":"空间长度","range":"0 m 至 4,5 m","cmc":"(2,1·L + 1,2) µm"}],"parameters_cs":[{"name":"Prostorová délka","range":"0 m až 4,5 m","cmc":"(2,1·L + 1,2) µm"}],"technique":"Pomiar wzorcem schodkowym","technique_en":"Measurement using a step gauge","technique_zh":"用阶梯规测量","technique_cs":"Měření stupňovou měrkou","techniques":["Pomiar wzorcem schodkowym"],"techniques_en":["Measurement using a step gauge"],"techniques_zh":["用阶梯规测量"],"techniques_cs":["Měření stupňovou měrkou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nDługość przestrzenna od 0 m do 4,5 m CMC (2,1·L + 1,2) µm\nPomiar wzorcem schodkowym","reference":"KP4 – RAMENA; ČSN EN ISO 10360-12; STN EN ISO 10360-12; MSZ EN ISO 10360-12; EN ISO 10360-12","norm_bases":["KP4 – RAMENA","ČSN EN ISO 10360-12","STN EN ISO 10360-12","MSZ EN ISO 10360-12","EN ISO 10360-12"],"lab_section":"Pracownia Budapeszt","lab_section_en":"Workplace Budapest","lab_section_zh":"布达佩斯工作场所","lab_section_cs":"Pracoviště Budapešť","lab_address":"Nagytétényi út 112, 1222 Budapest","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ramiona pomiarowe Wzorcowanie – długość Pomiar wzorcem schodkowym Długość przestrzenna od 0 m do 4,5 m CMC (2,1·L + 1,2) µm Měřicí ramena Kalibrace – délka Měření stupňovou měrkou Prostorová délka 0 m až 4,5 m CMC (2,1·L + 1,2) µm KP4 – RAMENA; ČSN EN ISO 10360-12; STN EN ISO 10360-12; MSZ EN ISO 10360-12; EN ISO 10360-12 Ramiona pomiarowe Wzorcowanie – dlugosc Pomiar wzorcem schodkowym Dlugosc przestrzenna od 0 m do 4,5 m CMC (2,1·L + 1,2) µm Merici ramena Kalibrace – delka Mereni stupnovou merkou Prostorova delka 0 m az 4,5 m CMC (2,1·L + 1,2) µm KP4 – RAMENA; CSN EN ISO 10360-12; STN EN ISO 10360-12; MSZ EN ISO 10360-12; EN ISO 10360-12","search_en":"Measuring arms Calibration – length Measurement using a step gauge Spatial length 0 m to 4,5 m CMC (2,1·L + 1,2) µm KP4 – RAMENA; ČSN EN ISO 10360-12; STN EN ISO 10360-12; MSZ EN ISO 10360-12; EN ISO 10360-12","search_zh":"测量臂 校准 – 长度 用阶梯规测量 空间长度 0 m 至 4,5 m CMC (2,1·L + 1,2) µm KP4 – RAMENA; ČSN EN ISO 10360-12; STN EN ISO 10360-12; MSZ EN ISO 10360-12; EN ISO 10360-12","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a87e37428b839b11c7a93434","lab_id":"6ade8b4cff06824761708139","country":"CZ","accr_number":"2397","accr_body":"ČIA","row_label":"3","test_object":"Ramiona pomiarowe","test_object_en":"Measuring arms","test_object_zh":"测量臂","test_object_cs":"Měřicí ramena","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"Błąd próbkowania kształtu","range":"od 0 mm do 1 mm","cmc":"1,0 µm"},{"name":"Błąd próbkowania wymiaru","range":"od -1 mm do 1 mm","cmc":"1,0 µm"},{"name":"Błąd próbkowania położenia","range":"od 0 mm do 1 mm","cmc":"1,0 µm"}],"parameters_en":[{"name":"Form sensing deviation","range":"0 mm to 1 mm","cmc":"1,0 µm"},{"name":"Size sensing deviation","range":"-1 mm to 1 mm","cmc":"1,0 µm"},{"name":"Position sensing deviation","range":"0 mm to 1 mm","cmc":"1,0 µm"}],"parameters_zh":[{"name":"形状探测误差","range":"0 mm 至 1 mm","cmc":"1,0 µm"},{"name":"尺寸探测误差","range":"-1 mm 至 1 mm","cmc":"1,0 µm"},{"name":"位置探测误差","range":"0 mm 至 1 mm","cmc":"1,0 µm"}],"parameters_cs":[{"name":"Chyba snímání tvaru","range":"0 mm až 1 mm","cmc":"1,0 µm"},{"name":"Chyba snímání rozměru","range":"-1 mm až 1 mm","cmc":"1,0 µm"},{"name":"Chyba snímání polohy","range":"0 mm až 1 mm","cmc":"1,0 µm"}],"technique":"Pomiar za pomocą kuli wzorcowej","technique_en":"Measurement using a calibration ball","technique_zh":"用校准球测量","technique_cs":"Měření pomocí kalibrační koule","techniques":["Pomiar za pomocą kuli wzorcowej"],"techniques_en":["Measurement using a calibration ball"],"techniques_zh":["用校准球测量"],"techniques_cs":["Měření pomocí kalibrační koule"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nBłąd próbkowania kształtu od 0 mm do 1 mm CMC 1,0 µm\nBłąd próbkowania wymiaru od -1 mm do 1 mm CMC 1,0 µm\nBłąd próbkowania położenia od 0 mm do 1 mm CMC 1,0 µm\nPomiar za pomocą kuli wzorcowej","reference":"KP4 – RAMENA; ČSN EN ISO 10360-12; STN EN ISO 10360-12; MSZ EN ISO 10360-12; EN ISO 10360-12","norm_bases":["KP4 – RAMENA","ČSN EN ISO 10360-12","STN EN ISO 10360-12","MSZ EN ISO 10360-12","EN ISO 10360-12"],"lab_section":"Pracownia Praga","lab_section_en":"Workplace Prague","lab_section_zh":"布拉格工作场所","lab_section_cs":"Pracoviště Praha","lab_address":"Boudníkova 2538/13, Libeň, 180 00 Praha 8","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ramiona pomiarowe Wzorcowanie – długość Pomiar za pomocą kuli wzorcowej Błąd próbkowania kształtu od 0 mm do 1 mm CMC 1,0 µm Błąd próbkowania wymiaru od -1 mm do 1 mm CMC 1,0 µm Błąd próbkowania położenia od 0 mm do 1 mm CMC 1,0 µm Měřicí ramena Kalibrace – délka Měření pomocí kalibrační koule Chyba snímání tvaru 0 mm až 1 mm CMC 1,0 µm Chyba snímání rozměru -1 mm až 1 mm CMC 1,0 µm Chyba snímání polohy 0 mm až 1 mm CMC 1,0 µm KP4 – RAMENA; ČSN EN ISO 10360-12; STN EN ISO 10360-12; MSZ EN ISO 10360-12; EN ISO 10360-12 Ramiona pomiarowe Wzorcowanie – dlugosc Pomiar za pomoca kuli wzorcowej Blad probkowania ksztaltu od 0 mm do 1 mm CMC 1,0 µm Blad probkowania wymiaru od -1 mm do 1 mm CMC 1,0 µm Blad probkowania polozenia od 0 mm do 1 mm CMC 1,0 µm Merici ramena Kalibrace – delka Mereni pomoci kalibracni koule Chyba snimani tvaru 0 mm az 1 mm CMC 1,0 µm Chyba snimani rozmeru -1 mm az 1 mm CMC 1,0 µm Chyba snimani polohy 0 mm az 1 mm CMC 1,0 µm KP4 – RAMENA; CSN EN ISO 10360-12; STN EN ISO 10360-12; MSZ EN ISO 10360-12; EN ISO 10360-12","search_en":"Measuring arms Calibration – length Measurement using a calibration ball Form sensing deviation 0 mm to 1 mm CMC 1,0 µm Size sensing deviation -1 mm to 1 mm CMC 1,0 µm Position sensing deviation 0 mm to 1 mm CMC 1,0 µm KP4 – RAMENA; ČSN EN ISO 10360-12; STN EN ISO 10360-12; MSZ EN ISO 10360-12; EN ISO 10360-12","search_zh":"测量臂 校准 – 长度 用校准球测量 形状探测误差 0 mm 至 1 mm CMC 1,0 µm 尺寸探测误差 -1 mm 至 1 mm CMC 1,0 µm 位置探测误差 0 mm 至 1 mm CMC 1,0 µm KP4 – RAMENA; ČSN EN ISO 10360-12; STN EN ISO 10360-12; MSZ EN ISO 10360-12; EN ISO 10360-12","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2da2aea58104d3403561cad9","lab_id":"6ade8b4cff06824761708139","country":"CZ","accr_number":"2397","accr_body":"ČIA","row_label":"3","test_object":"Ramiona pomiarowe","test_object_en":"Measuring arms","test_object_zh":"测量臂","test_object_cs":"Měřicí ramena","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"Błąd próbkowania kształtu","range":"od 0 mm do 1 mm","cmc":"1,0 µm"},{"name":"Błąd próbkowania wymiaru","range":"od -1 mm do 1 mm","cmc":"1,0 µm"},{"name":"Błąd próbkowania położenia","range":"od 0 mm do 1 mm","cmc":"1,0 µm"}],"parameters_en":[{"name":"Form sensing deviation","range":"0 mm to 1 mm","cmc":"1,0 µm"},{"name":"Size sensing deviation","range":"-1 mm to 1 mm","cmc":"1,0 µm"},{"name":"Position sensing deviation","range":"0 mm to 1 mm","cmc":"1,0 µm"}],"parameters_zh":[{"name":"形状探测误差","range":"0 mm 至 1 mm","cmc":"1,0 µm"},{"name":"尺寸探测误差","range":"-1 mm 至 1 mm","cmc":"1,0 µm"},{"name":"位置探测误差","range":"0 mm 至 1 mm","cmc":"1,0 µm"}],"parameters_cs":[{"name":"Chyba snímání tvaru","range":"0 mm až 1 mm","cmc":"1,0 µm"},{"name":"Chyba snímání rozměru","range":"-1 mm až 1 mm","cmc":"1,0 µm"},{"name":"Chyba snímání polohy","range":"0 mm až 1 mm","cmc":"1,0 µm"}],"technique":"Pomiar za pomocą kuli wzorcowej","technique_en":"Measurement using a calibration ball","technique_zh":"用校准球测量","technique_cs":"Měření pomocí kalibrační koule","techniques":["Pomiar za pomocą kuli wzorcowej"],"techniques_en":["Measurement using a calibration ball"],"techniques_zh":["用校准球测量"],"techniques_cs":["Měření pomocí kalibrační koule"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nBłąd próbkowania kształtu od 0 mm do 1 mm CMC 1,0 µm\nBłąd próbkowania wymiaru od -1 mm do 1 mm CMC 1,0 µm\nBłąd próbkowania położenia od 0 mm do 1 mm CMC 1,0 µm\nPomiar za pomocą kuli wzorcowej","reference":"KP4 – RAMENA; ČSN EN ISO 10360-12; STN EN ISO 10360-12; MSZ EN ISO 10360-12; EN ISO 10360-12","norm_bases":["KP4 – RAMENA","ČSN EN ISO 10360-12","STN EN ISO 10360-12","MSZ EN ISO 10360-12","EN ISO 10360-12"],"lab_section":"Pracownia Bratysława","lab_section_en":"Workplace Bratislava","lab_section_zh":"布拉迪斯拉发工作场所","lab_section_cs":"Pracoviště Bratislava","lab_address":"Tuhovská 10722/29, 831 06 Bratislava – Vajnory","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ramiona pomiarowe Wzorcowanie – długość Pomiar za pomocą kuli wzorcowej Błąd próbkowania kształtu od 0 mm do 1 mm CMC 1,0 µm Błąd próbkowania wymiaru od -1 mm do 1 mm CMC 1,0 µm Błąd próbkowania położenia od 0 mm do 1 mm CMC 1,0 µm Měřicí ramena Kalibrace – délka Měření pomocí kalibrační koule Chyba snímání tvaru 0 mm až 1 mm CMC 1,0 µm Chyba snímání rozměru -1 mm až 1 mm CMC 1,0 µm Chyba snímání polohy 0 mm až 1 mm CMC 1,0 µm KP4 – RAMENA; ČSN EN ISO 10360-12; STN EN ISO 10360-12; MSZ EN ISO 10360-12; EN ISO 10360-12 Ramiona pomiarowe Wzorcowanie – dlugosc Pomiar za pomoca kuli wzorcowej Blad probkowania ksztaltu od 0 mm do 1 mm CMC 1,0 µm Blad probkowania wymiaru od -1 mm do 1 mm CMC 1,0 µm Blad probkowania polozenia od 0 mm do 1 mm CMC 1,0 µm Merici ramena Kalibrace – delka Mereni pomoci kalibracni koule Chyba snimani tvaru 0 mm az 1 mm CMC 1,0 µm Chyba snimani rozmeru -1 mm az 1 mm CMC 1,0 µm Chyba snimani polohy 0 mm az 1 mm CMC 1,0 µm KP4 – RAMENA; CSN EN ISO 10360-12; STN EN ISO 10360-12; MSZ EN ISO 10360-12; EN ISO 10360-12","search_en":"Measuring arms Calibration – length Measurement using a calibration ball Form sensing deviation 0 mm to 1 mm CMC 1,0 µm Size sensing deviation -1 mm to 1 mm CMC 1,0 µm Position sensing deviation 0 mm to 1 mm CMC 1,0 µm KP4 – RAMENA; ČSN EN ISO 10360-12; STN EN ISO 10360-12; MSZ EN ISO 10360-12; EN ISO 10360-12","search_zh":"测量臂 校准 – 长度 用校准球测量 形状探测误差 0 mm 至 1 mm CMC 1,0 µm 尺寸探测误差 -1 mm 至 1 mm CMC 1,0 µm 位置探测误差 0 mm 至 1 mm CMC 1,0 µm KP4 – RAMENA; ČSN EN ISO 10360-12; STN EN ISO 10360-12; MSZ EN ISO 10360-12; EN ISO 10360-12","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"57e442676f42e78690124d23","lab_id":"6ade8b4cff06824761708139","country":"CZ","accr_number":"2397","accr_body":"ČIA","row_label":"3","test_object":"Ramiona pomiarowe","test_object_en":"Measuring arms","test_object_zh":"测量臂","test_object_cs":"Měřicí ramena","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"Błąd próbkowania kształtu","range":"od 0 mm do 1 mm","cmc":"1,0 µm"},{"name":"Błąd próbkowania wymiaru","range":"od -1 mm do 1 mm","cmc":"1,0 µm"},{"name":"Błąd próbkowania położenia","range":"od 0 mm do 1 mm","cmc":"1,0 µm"}],"parameters_en":[{"name":"Form sensing deviation","range":"0 mm to 1 mm","cmc":"1,0 µm"},{"name":"Size sensing deviation","range":"-1 mm to 1 mm","cmc":"1,0 µm"},{"name":"Position sensing deviation","range":"0 mm to 1 mm","cmc":"1,0 µm"}],"parameters_zh":[{"name":"形状探测误差","range":"0 mm 至 1 mm","cmc":"1,0 µm"},{"name":"尺寸探测误差","range":"-1 mm 至 1 mm","cmc":"1,0 µm"},{"name":"位置探测误差","range":"0 mm 至 1 mm","cmc":"1,0 µm"}],"parameters_cs":[{"name":"Chyba snímání tvaru","range":"0 mm až 1 mm","cmc":"1,0 µm"},{"name":"Chyba snímání rozměru","range":"-1 mm až 1 mm","cmc":"1,0 µm"},{"name":"Chyba snímání polohy","range":"0 mm až 1 mm","cmc":"1,0 µm"}],"technique":"Pomiar za pomocą kuli wzorcowej","technique_en":"Measurement using a calibration ball","technique_zh":"用校准球测量","technique_cs":"Měření pomocí kalibrační koule","techniques":["Pomiar za pomocą kuli wzorcowej"],"techniques_en":["Measurement using a calibration ball"],"techniques_zh":["用校准球测量"],"techniques_cs":["Měření pomocí kalibrační koule"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nBłąd próbkowania kształtu od 0 mm do 1 mm CMC 1,0 µm\nBłąd próbkowania wymiaru od -1 mm do 1 mm CMC 1,0 µm\nBłąd próbkowania położenia od 0 mm do 1 mm CMC 1,0 µm\nPomiar za pomocą kuli wzorcowej","reference":"KP4 – RAMENA; ČSN EN ISO 10360-12; STN EN ISO 10360-12; MSZ EN ISO 10360-12; EN ISO 10360-12","norm_bases":["KP4 – RAMENA","ČSN EN ISO 10360-12","STN EN ISO 10360-12","MSZ EN ISO 10360-12","EN ISO 10360-12"],"lab_section":"Pracownia Budapeszt","lab_section_en":"Workplace Budapest","lab_section_zh":"布达佩斯工作场所","lab_section_cs":"Pracoviště Budapešť","lab_address":"Nagytétényi út 112, 1222 Budapest","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ramiona pomiarowe Wzorcowanie – długość Pomiar za pomocą kuli wzorcowej Błąd próbkowania kształtu od 0 mm do 1 mm CMC 1,0 µm Błąd próbkowania wymiaru od -1 mm do 1 mm CMC 1,0 µm Błąd próbkowania położenia od 0 mm do 1 mm CMC 1,0 µm Měřicí ramena Kalibrace – délka Měření pomocí kalibrační koule Chyba snímání tvaru 0 mm až 1 mm CMC 1,0 µm Chyba snímání rozměru -1 mm až 1 mm CMC 1,0 µm Chyba snímání polohy 0 mm až 1 mm CMC 1,0 µm KP4 – RAMENA; ČSN EN ISO 10360-12; STN EN ISO 10360-12; MSZ EN ISO 10360-12; EN ISO 10360-12 Ramiona pomiarowe Wzorcowanie – dlugosc Pomiar za pomoca kuli wzorcowej Blad probkowania ksztaltu od 0 mm do 1 mm CMC 1,0 µm Blad probkowania wymiaru od -1 mm do 1 mm CMC 1,0 µm Blad probkowania polozenia od 0 mm do 1 mm CMC 1,0 µm Merici ramena Kalibrace – delka Mereni pomoci kalibracni koule Chyba snimani tvaru 0 mm az 1 mm CMC 1,0 µm Chyba snimani rozmeru -1 mm az 1 mm CMC 1,0 µm Chyba snimani polohy 0 mm az 1 mm CMC 1,0 µm KP4 – RAMENA; CSN EN ISO 10360-12; STN EN ISO 10360-12; MSZ EN ISO 10360-12; EN ISO 10360-12","search_en":"Measuring arms Calibration – length Measurement using a calibration ball Form sensing deviation 0 mm to 1 mm CMC 1,0 µm Size sensing deviation -1 mm to 1 mm CMC 1,0 µm Position sensing deviation 0 mm to 1 mm CMC 1,0 µm KP4 – RAMENA; ČSN EN ISO 10360-12; STN EN ISO 10360-12; MSZ EN ISO 10360-12; EN ISO 10360-12","search_zh":"测量臂 校准 – 长度 用校准球测量 形状探测误差 0 mm 至 1 mm CMC 1,0 µm 尺寸探测误差 -1 mm 至 1 mm CMC 1,0 µm 位置探测误差 0 mm 至 1 mm CMC 1,0 µm KP4 – RAMENA; ČSN EN ISO 10360-12; STN EN ISO 10360-12; MSZ EN ISO 10360-12; EN ISO 10360-12","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a8d6dc8f27c606fd61488a9f","lab_id":"6ade8b4cff06824761708139","country":"CZ","accr_number":"2397","accr_body":"ČIA","row_label":"4","test_object":"Trackery laserowe","test_object_en":"Laser trackers","test_object_zh":"激光跟踪仪","test_object_cs":"Trakční lasery","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"Błąd pomiaru odległości; odległość 1,5 m do 53 m","range":"od -0,05 mm do 0,05 mm","cmc":"5 µm"}],"parameters_en":[{"name":"Distance measurement deviation; length 1,5 m to 53 m","range":"-0,05 mm to 0,05 mm","cmc":"5 µm"}],"parameters_zh":[{"name":"距离测量误差；距离 1,5 m 至 53 m","range":"-0,05 mm 至 0,05 mm","cmc":"5 µm"}],"parameters_cs":[{"name":"Chyba měření vzdálenosti; vzdálenost 1,5 m až 53 m","range":"-0,05 mm až 0,05 mm","cmc":"5 µm"}],"technique":"Porównanie z wzorcowym trackerem laserowym","technique_en":"Comparison with a reference laser tracker","technique_zh":"与标准激光跟踪仪比较","technique_cs":"Porovnání s etalonovým trakčním laserem","techniques":["Porównanie z wzorcowym trackerem laserowym"],"techniques_en":["Comparison with a reference laser tracker"],"techniques_zh":["与标准激光跟踪仪比较"],"techniques_cs":["Porovnání s etalonovým trakčním laserem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nBłąd pomiaru odległości; odległość 1,5 m do 53 m od -0,05 mm do 0,05 mm CMC 5 µm\nPorównanie z wzorcowym trackerem laserowym","reference":"KP7 – TRAKČNÍ LASER 2; ČSN EN ISO 10 360-10; EN ISO 10 360-10","norm_bases":["KP7 – TRAKČNÍ LASER 2","ČSN EN ISO 10 360-10","EN ISO 10 360-10"],"lab_section":"Pracownia Praga","lab_section_en":"Workplace Prague","lab_section_zh":"布拉格工作场所","lab_section_cs":"Pracoviště Praha","lab_address":"Boudníkova 2538/13, Libeň, 180 00 Praha 8","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Trackery laserowe Wzorcowanie – długość Porównanie z wzorcowym trackerem laserowym Błąd pomiaru odległości; odległość 1,5 m do 53 m od -0,05 mm do 0,05 mm CMC 5 µm Trakční lasery Kalibrace – délka Porovnání s etalonovým trakčním laserem Chyba měření vzdálenosti; vzdálenost 1,5 m až 53 m -0,05 mm až 0,05 mm CMC 5 µm KP7 – TRAKČNÍ LASER 2; ČSN EN ISO 10 360-10; EN ISO 10 360-10 Trackery laserowe Wzorcowanie – dlugosc Porownanie z wzorcowym trackerem laserowym Blad pomiaru odleglosci; odleglosc 1,5 m do 53 m od -0,05 mm do 0,05 mm CMC 5 µm Trakcni lasery Kalibrace – delka Porovnani s etalonovym trakcnim laserem Chyba mereni vzdalenosti; vzdalenost 1,5 m az 53 m -0,05 mm az 0,05 mm CMC 5 µm KP7 – TRAKCNI LASER 2; CSN EN ISO 10 360-10; EN ISO 10 360-10","search_en":"Laser trackers Calibration – length Comparison with a reference laser tracker Distance measurement deviation; length 1,5 m to 53 m -0,05 mm to 0,05 mm CMC 5 µm KP7 – TRAKČNÍ LASER 2; ČSN EN ISO 10 360-10; EN ISO 10 360-10","search_zh":"激光跟踪仪 校准 – 长度 与标准激光跟踪仪比较 距离测量误差；距离 1,5 m 至 53 m -0,05 mm 至 0,05 mm CMC 5 µm KP7 – TRAKČNÍ LASER 2; ČSN EN ISO 10 360-10; EN ISO 10 360-10","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"43ca6c70d36ef78bfa176d13","lab_id":"6ade8b4cff06824761708139","country":"CZ","accr_number":"2397","accr_body":"ČIA","row_label":"4","test_object":"Trackery laserowe","test_object_en":"Laser trackers","test_object_zh":"激光跟踪仪","test_object_cs":"Trakční lasery","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"Błąd pomiaru dwustronnego; odległość 1,5 m do 53 m","range":"od -0,4 mm do 0,4 mm","cmc":"6 µm"}],"parameters_en":[{"name":"Two face measurement deviation; length 1,5 m to 53 m","range":"-0,4 mm to 0,4 mm","cmc":"6 µm"}],"parameters_zh":[{"name":"双面测量误差；距离 1,5 m 至 53 m","range":"-0,4 mm 至 0,4 mm","cmc":"6 µm"}],"parameters_cs":[{"name":"Chyba oboustranného měření; vzdálenost 1,5 m až 53 m","range":"-0,4 mm až 0,4 mm","cmc":"6 µm"}],"technique":"Pomiar dwustronny reflektorem","technique_en":"Two face measurement by reflector","technique_zh":"用反射器双面测量","technique_cs":"Oboustranné měření odražečem","techniques":["Pomiar dwustronny reflektorem"],"techniques_en":["Two face measurement by reflector"],"techniques_zh":["用反射器双面测量"],"techniques_cs":["Oboustranné měření odražečem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nBłąd pomiaru dwustronnego; odległość 1,5 m do 53 m od -0,4 mm do 0,4 mm CMC 6 µm\nPomiar dwustronny reflektorem","reference":"KP6 – TRAKČNÍ LASER 1; KP7 – TRAKČNÍ LASER 2; ČSN EN ISO 10 360-10; EN ISO 10 360-10","norm_bases":["KP6 – TRAKČNÍ LASER 1","KP7 – TRAKČNÍ LASER 2","ČSN EN ISO 10 360-10","EN ISO 10 360-10"],"lab_section":"Pracownia Praga","lab_section_en":"Workplace Prague","lab_section_zh":"布拉格工作场所","lab_section_cs":"Pracoviště Praha","lab_address":"Boudníkova 2538/13, Libeň, 180 00 Praha 8","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Trackery laserowe Wzorcowanie – długość Pomiar dwustronny reflektorem Błąd pomiaru dwustronnego; odległość 1,5 m do 53 m od -0,4 mm do 0,4 mm CMC 6 µm Trakční lasery Kalibrace – délka Oboustranné měření odražečem Chyba oboustranného měření; vzdálenost 1,5 m až 53 m -0,4 mm až 0,4 mm CMC 6 µm KP6 – TRAKČNÍ LASER 1; KP7 – TRAKČNÍ LASER 2; ČSN EN ISO 10 360-10; EN ISO 10 360-10 Trackery laserowe Wzorcowanie – dlugosc Pomiar dwustronny reflektorem Blad pomiaru dwustronnego; odleglosc 1,5 m do 53 m od -0,4 mm do 0,4 mm CMC 6 µm Trakcni lasery Kalibrace – delka Oboustranne mereni odrazecem Chyba oboustranneho mereni; vzdalenost 1,5 m az 53 m -0,4 mm az 0,4 mm CMC 6 µm KP6 – TRAKCNI LASER 1; KP7 – TRAKCNI LASER 2; CSN EN ISO 10 360-10; EN ISO 10 360-10","search_en":"Laser trackers Calibration – length Two face measurement by reflector Two face measurement deviation; length 1,5 m to 53 m -0,4 mm to 0,4 mm CMC 6 µm KP6 – TRAKČNÍ LASER 1; KP7 – TRAKČNÍ LASER 2; ČSN EN ISO 10 360-10; EN ISO 10 360-10","search_zh":"激光跟踪仪 校准 – 长度 用反射器双面测量 双面测量误差；距离 1,5 m 至 53 m -0,4 mm 至 0,4 mm CMC 6 µm KP6 – TRAKČNÍ LASER 1; KP7 – TRAKČNÍ LASER 2; ČSN EN ISO 10 360-10; EN ISO 10 360-10","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"70cd0e16350e98b75ebc177a","lab_id":"6ade8b4cff06824761708139","country":"CZ","accr_number":"2397","accr_body":"ČIA","row_label":"4","test_object":"Trackery laserowe","test_object_en":"Laser trackers","test_object_zh":"激光跟踪仪","test_object_cs":"Trakční lasery","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"Błąd długości przestrzennej przy próbkowaniu sondą; odległość 1,5 m do 25 m","range":"od -0,5 mm do 0,5 mm","cmc":"12 µm"},{"name":"Błąd długości przestrzennej przy próbkowaniu reflektorem; odległość 1,5 m do 25 m","range":"od -0,5 mm do 0,5 mm","cmc":"9 µm"}],"parameters_en":[{"name":"Spatial length deviation in probe sensing; length 1,5 m to 25 m","range":"-0,5 mm to 0,5 mm","cmc":"12 µm"},{"name":"Spatial length deviation in reflector sensing; length 1,5 m to 25 m","range":"-0,5 mm to 0,5 mm","cmc":"9 µm"}],"parameters_zh":[{"name":"探针探测时的空间长度误差；距离 1,5 m 至 25 m","range":"-0,5 mm 至 0,5 mm","cmc":"12 µm"},{"name":"反射器探测时的空间长度误差；距离 1,5 m 至 25 m","range":"-0,5 mm 至 0,5 mm","cmc":"9 µm"}],"parameters_cs":[{"name":"Chyba prostorové délky při snímání sondou; vzdálenost 1,5 m až 25 m","range":"-0,5 mm až 0,5 mm","cmc":"12 µm"},{"name":"Chyba prostorové délky při snímání odražečem; vzdálenost 1,5 m až 25 m","range":"-0,5 mm až 0,5 mm","cmc":"9 µm"}],"technique":"Pomiar za pomocą pręta wzorcowego","technique_en":"Measurement using a scale bar","technique_zh":"用标准杆测量","technique_cs":"Měření pomocí etalonové tyče","techniques":["Pomiar za pomocą pręta wzorcowego"],"techniques_en":["Measurement using a scale bar"],"techniques_zh":["用标准杆测量"],"techniques_cs":["Měření pomocí etalonové tyče"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nBłąd długości przestrzennej przy próbkowaniu sondą; odległość 1,5 m do 25 m od -0,5 mm do 0,5 mm CMC 12 µm\nBłąd długości przestrzennej przy próbkowaniu reflektorem; odległość 1,5 m do 25 m od -0,5 mm do 0,5 mm CMC 9 µm\nPomiar za pomocą pręta wzorcowego","reference":"KP6 – TRAKČNÍ LASER 1; KP7 – TRAKČNÍ LASER 2; ČSN EN ISO 10 360-10; EN ISO 10 360-10","norm_bases":["KP6 – TRAKČNÍ LASER 1","KP7 – TRAKČNÍ LASER 2","ČSN EN ISO 10 360-10","EN ISO 10 360-10"],"lab_section":"Pracownia Praga","lab_section_en":"Workplace Prague","lab_section_zh":"布拉格工作场所","lab_section_cs":"Pracoviště Praha","lab_address":"Boudníkova 2538/13, Libeň, 180 00 Praha 8","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Trackery laserowe Wzorcowanie – długość Pomiar za pomocą pręta wzorcowego Błąd długości przestrzennej przy próbkowaniu sondą; odległość 1,5 m do 25 m od -0,5 mm do 0,5 mm CMC 12 µm Błąd długości przestrzennej przy próbkowaniu reflektorem; odległość 1,5 m do 25 m od -0,5 mm do 0,5 mm CMC 9 µm Trakční lasery Kalibrace – délka Měření pomocí etalonové tyče Chyba prostorové délky při snímání sondou; vzdálenost 1,5 m až 25 m -0,5 mm až 0,5 mm CMC 12 µm Chyba prostorové délky při snímání odražečem; vzdálenost 1,5 m až 25 m -0,5 mm až 0,5 mm CMC 9 µm KP6 – TRAKČNÍ LASER 1; KP7 – TRAKČNÍ LASER 2; ČSN EN ISO 10 360-10; EN ISO 10 360-10 Trackery laserowe Wzorcowanie – dlugosc Pomiar za pomoca preta wzorcowego Blad dlugosci przestrzennej przy probkowaniu sonda; odleglosc 1,5 m do 25 m od -0,5 mm do 0,5 mm CMC 12 µm Blad dlugosci przestrzennej przy probkowaniu reflektorem; odleglosc 1,5 m do 25 m od -0,5 mm do 0,5 mm CMC 9 µm Trakcni lasery Kalibrace – delka Mereni pomoci etalonove tyce Chyba prostorove delky pri snimani sondou; vzdalenost 1,5 m az 25 m -0,5 mm az 0,5 mm CMC 12 µm Chyba prostorove delky pri snimani odrazecem; vzdalenost 1,5 m az 25 m -0,5 mm az 0,5 mm CMC 9 µm KP6 – TRAKCNI LASER 1; KP7 – TRAKCNI LASER 2; CSN EN ISO 10 360-10; EN ISO 10 360-10","search_en":"Laser trackers Calibration – length Measurement using a scale bar Spatial length deviation in probe sensing; length 1,5 m to 25 m -0,5 mm to 0,5 mm CMC 12 µm Spatial length deviation in reflector sensing; length 1,5 m to 25 m -0,5 mm to 0,5 mm CMC 9 µm KP6 – TRAKČNÍ LASER 1; KP7 – TRAKČNÍ LASER 2; ČSN EN ISO 10 360-10; EN ISO 10 360-10","search_zh":"激光跟踪仪 校准 – 长度 用标准杆测量 探针探测时的空间长度误差；距离 1,5 m 至 25 m -0,5 mm 至 0,5 mm CMC 12 µm 反射器探测时的空间长度误差；距离 1,5 m 至 25 m -0,5 mm 至 0,5 mm CMC 9 µm KP6 – TRAKČNÍ LASER 1; KP7 – TRAKČNÍ LASER 2; ČSN EN ISO 10 360-10; EN ISO 10 360-10","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a3bfd902fe4267190982a8df","lab_id":"6ade8b4cff06824761708139","country":"CZ","accr_number":"2397","accr_body":"ČIA","row_label":"4","test_object":"Trackery laserowe","test_object_en":"Laser trackers","test_object_zh":"激光跟踪仪","test_object_cs":"Trakční lasery","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"Błąd próbkowania wymiaru; odległość 2 m do 20 m","range":"od -0,2 mm do 0,2 mm","cmc":"6 µm"},{"name":"Błąd próbkowania kształtu; odległość 2 m do 20 m","range":"od 0 mm do 0,4 mm","cmc":"8 µm"}],"parameters_en":[{"name":"Size sensing deviation; length 2 m to 20 m","range":"-0,2 mm to 0,2 mm","cmc":"6 µm"},{"name":"Form sensing deviation; length 2 m to 20 m","range":"0 mm to 0,4 mm","cmc":"8 µm"}],"parameters_zh":[{"name":"尺寸探测误差；距离 2 m 至 20 m","range":"-0,2 mm 至 0,2 mm","cmc":"6 µm"},{"name":"形状探测误差；距离 2 m 至 20 m","range":"0 mm 至 0,4 mm","cmc":"8 µm"}],"parameters_cs":[{"name":"Chyba snímání rozměru; vzdálenost 2 m až 20 m","range":"-0,2 mm až 0,2 mm","cmc":"6 µm"},{"name":"Chyba snímání tvaru; vzdálenost 2 m až 20 m","range":"0 mm až 0,4 mm","cmc":"8 µm"}],"technique":"Pomiar za pomocą kuli wzorcowej","technique_en":"Measurement using a calibration ball","technique_zh":"用校准球测量","technique_cs":"Měření pomocí kalibrační koule","techniques":["Pomiar za pomocą kuli wzorcowej"],"techniques_en":["Measurement using a calibration ball"],"techniques_zh":["用校准球测量"],"techniques_cs":["Měření pomocí kalibrační koule"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nBłąd próbkowania wymiaru; odległość 2 m do 20 m od -0,2 mm do 0,2 mm CMC 6 µm\nBłąd próbkowania kształtu; odległość 2 m do 20 m od 0 mm do 0,4 mm CMC 8 µm\nPomiar za pomocą kuli wzorcowej","reference":"KP7 – TRAKČNÍ LASER 2; ČSN EN ISO 10 360-10; EN ISO 10 360-10","norm_bases":["KP7 – TRAKČNÍ LASER 2","ČSN EN ISO 10 360-10","EN ISO 10 360-10"],"lab_section":"Pracownia Praga","lab_section_en":"Workplace Prague","lab_section_zh":"布拉格工作场所","lab_section_cs":"Pracoviště Praha","lab_address":"Boudníkova 2538/13, Libeň, 180 00 Praha 8","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Trackery laserowe Wzorcowanie – długość Pomiar za pomocą kuli wzorcowej Błąd próbkowania wymiaru; odległość 2 m do 20 m od -0,2 mm do 0,2 mm CMC 6 µm Błąd próbkowania kształtu; odległość 2 m do 20 m od 0 mm do 0,4 mm CMC 8 µm Trakční lasery Kalibrace – délka Měření pomocí kalibrační koule Chyba snímání rozměru; vzdálenost 2 m až 20 m -0,2 mm až 0,2 mm CMC 6 µm Chyba snímání tvaru; vzdálenost 2 m až 20 m 0 mm až 0,4 mm CMC 8 µm KP7 – TRAKČNÍ LASER 2; ČSN EN ISO 10 360-10; EN ISO 10 360-10 Trackery laserowe Wzorcowanie – dlugosc Pomiar za pomoca kuli wzorcowej Blad probkowania wymiaru; odleglosc 2 m do 20 m od -0,2 mm do 0,2 mm CMC 6 µm Blad probkowania ksztaltu; odleglosc 2 m do 20 m od 0 mm do 0,4 mm CMC 8 µm Trakcni lasery Kalibrace – delka Mereni pomoci kalibracni koule Chyba snimani rozmeru; vzdalenost 2 m az 20 m -0,2 mm az 0,2 mm CMC 6 µm Chyba snimani tvaru; vzdalenost 2 m az 20 m 0 mm az 0,4 mm CMC 8 µm KP7 – TRAKCNI LASER 2; CSN EN ISO 10 360-10; EN ISO 10 360-10","search_en":"Laser trackers Calibration – length Measurement using a calibration ball Size sensing deviation; length 2 m to 20 m -0,2 mm to 0,2 mm CMC 6 µm Form sensing deviation; length 2 m to 20 m 0 mm to 0,4 mm CMC 8 µm KP7 – TRAKČNÍ LASER 2; ČSN EN ISO 10 360-10; EN ISO 10 360-10","search_zh":"激光跟踪仪 校准 – 长度 用校准球测量 尺寸探测误差；距离 2 m 至 20 m -0,2 mm 至 0,2 mm CMC 6 µm 形状探测误差；距离 2 m 至 20 m 0 mm 至 0,4 mm CMC 8 µm KP7 – TRAKČNÍ LASER 2; ČSN EN ISO 10 360-10; EN ISO 10 360-10","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"23d7a04531623ca9fba8b161","lab_id":"6ade8b4cff06824761708139","country":"CZ","accr_number":"2397","accr_body":"ČIA","row_label":"4","test_object":"Trackery laserowe","test_object_en":"Laser trackers","test_object_zh":"激光跟踪仪","test_object_cs":"Trakční lasery","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"Błąd próbkowania płaszczyzny; odległość 2 m do 20 m","range":"od 0 mm do 0,5 mm","cmc":"12 µm"}],"parameters_en":[{"name":"Plane sensing deviation; length 2 m to 20 m","range":"0 mm to 0,5 mm","cmc":"12 µm"}],"parameters_zh":[{"name":"平面探测误差；距离 2 m 至 20 m","range":"0 mm 至 0,5 mm","cmc":"12 µm"}],"parameters_cs":[{"name":"Chyba snímání plochy; vzdálenost 2 m až 20 m","range":"0 mm až 0,5 mm","cmc":"12 µm"}],"technique":"Pomiar za pomocą płyty wzorcowej czujnikiem optycznym (skanowanie)","technique_en":"Measurement using a reference plate by an optical sensor (scanning)","technique_zh":"用光学传感器借助标准板测量（扫描）","technique_cs":"Měření pomocí etalonoví desky optickým snímačem (skenování)","techniques":["Pomiar za pomocą płyty wzorcowej czujnikiem optycznym (skanowanie)"],"techniques_en":["Measurement using a reference plate by an optical sensor (scanning)"],"techniques_zh":["用光学传感器借助标准板测量（扫描）"],"techniques_cs":["Měření pomocí etalonoví desky optickým snímačem (skenování)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nBłąd próbkowania płaszczyzny; odległość 2 m do 20 m od 0 mm do 0,5 mm CMC 12 µm\nPomiar za pomocą płyty wzorcowej czujnikiem optycznym (skanowanie)","reference":"KP7 – TRAKČNÍ LASER 2; ČSN EN ISO 10 360-10; EN ISO 10 360-10","norm_bases":["KP7 – TRAKČNÍ LASER 2","ČSN EN ISO 10 360-10","EN ISO 10 360-10"],"lab_section":"Pracownia Praga","lab_section_en":"Workplace Prague","lab_section_zh":"布拉格工作场所","lab_section_cs":"Pracoviště Praha","lab_address":"Boudníkova 2538/13, Libeň, 180 00 Praha 8","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Trackery laserowe Wzorcowanie – długość Pomiar za pomocą płyty wzorcowej czujnikiem optycznym (skanowanie) Błąd próbkowania płaszczyzny; odległość 2 m do 20 m od 0 mm do 0,5 mm CMC 12 µm Trakční lasery Kalibrace – délka Měření pomocí etalonoví desky optickým snímačem (skenování) Chyba snímání plochy; vzdálenost 2 m až 20 m 0 mm až 0,5 mm CMC 12 µm KP7 – TRAKČNÍ LASER 2; ČSN EN ISO 10 360-10; EN ISO 10 360-10 Trackery laserowe Wzorcowanie – dlugosc Pomiar za pomoca plyty wzorcowej czujnikiem optycznym (skanowanie) Blad probkowania plaszczyzny; odleglosc 2 m do 20 m od 0 mm do 0,5 mm CMC 12 µm Trakcni lasery Kalibrace – delka Mereni pomoci etalonovi desky optickym snimacem (skenovani) Chyba snimani plochy; vzdalenost 2 m az 20 m 0 mm az 0,5 mm CMC 12 µm KP7 – TRAKCNI LASER 2; CSN EN ISO 10 360-10; EN ISO 10 360-10","search_en":"Laser trackers Calibration – length Measurement using a reference plate by an optical sensor (scanning) Plane sensing deviation; length 2 m to 20 m 0 mm to 0,5 mm CMC 12 µm KP7 – TRAKČNÍ LASER 2; ČSN EN ISO 10 360-10; EN ISO 10 360-10","search_zh":"激光跟踪仪 校准 – 长度 用光学传感器借助标准板测量（扫描） 平面探测误差；距离 2 m 至 20 m 0 mm 至 0,5 mm CMC 12 µm KP7 – TRAKČNÍ LASER 2; ČSN EN ISO 10 360-10; EN ISO 10 360-10","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7aaa522324b9ffc0e842dece","lab_id":"6ade8b4cff06824761708139","country":"CZ","accr_number":"2397","accr_body":"ČIA","row_label":"4","test_object":"Trackery laserowe","test_object_en":"Laser trackers","test_object_zh":"激光跟踪仪","test_object_cs":"Trakční lasery","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"Błąd orientacji; odległość 2 m do 10 m","range":"od 0 mm do 0,2 mm","cmc":"10 µm"}],"parameters_en":[{"name":"Orientation deviation; length 2 m to 10 m","range":"0 mm to 0,2 mm","cmc":"10 µm"}],"parameters_zh":[{"name":"方向误差；距离 2 m 至 10 m","range":"0 mm 至 0,2 mm","cmc":"10 µm"}],"parameters_cs":[{"name":"Chyba orientace; vzdálenost 2 m až 10 m","range":"0 mm až 0,2 mm","cmc":"10 µm"}],"technique":"Pomiar wielopozycyjny sondą przełączającą","technique_en":"Multi-position measurement with a switching tactile probe","technique_zh":"用触发式测头进行多位置测量","technique_cs":"Vícepolohové měření spínacím snímačem","techniques":["Pomiar wielopozycyjny sondą przełączającą"],"techniques_en":["Multi-position measurement with a switching tactile probe"],"techniques_zh":["用触发式测头进行多位置测量"],"techniques_cs":["Vícepolohové měření spínacím snímačem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nBłąd orientacji; odległość 2 m do 10 m od 0 mm do 0,2 mm CMC 10 µm\nPomiar wielopozycyjny sondą przełączającą","reference":"KP7 – TRAKČNÍ LASER 2; ČSN EN ISO 10 360-10; EN ISO 10 360-10","norm_bases":["KP7 – TRAKČNÍ LASER 2","ČSN EN ISO 10 360-10","EN ISO 10 360-10"],"lab_section":"Pracownia Praga","lab_section_en":"Workplace Prague","lab_section_zh":"布拉格工作场所","lab_section_cs":"Pracoviště Praha","lab_address":"Boudníkova 2538/13, Libeň, 180 00 Praha 8","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Trackery laserowe Wzorcowanie – długość Pomiar wielopozycyjny sondą przełączającą Błąd orientacji; odległość 2 m do 10 m od 0 mm do 0,2 mm CMC 10 µm Trakční lasery Kalibrace – délka Vícepolohové měření spínacím snímačem Chyba orientace; vzdálenost 2 m až 10 m 0 mm až 0,2 mm CMC 10 µm KP7 – TRAKČNÍ LASER 2; ČSN EN ISO 10 360-10; EN ISO 10 360-10 Trackery laserowe Wzorcowanie – dlugosc Pomiar wielopozycyjny sonda przelaczajaca Blad orientacji; odleglosc 2 m do 10 m od 0 mm do 0,2 mm CMC 10 µm Trakcni lasery Kalibrace – delka Vicepolohove mereni spinacim snimacem Chyba orientace; vzdalenost 2 m az 10 m 0 mm az 0,2 mm CMC 10 µm KP7 – TRAKCNI LASER 2; CSN EN ISO 10 360-10; EN ISO 10 360-10","search_en":"Laser trackers Calibration – length Multi-position measurement with a switching tactile probe Orientation deviation; length 2 m to 10 m 0 mm to 0,2 mm CMC 10 µm KP7 – TRAKČNÍ LASER 2; ČSN EN ISO 10 360-10; EN ISO 10 360-10","search_zh":"激光跟踪仪 校准 – 长度 用触发式测头进行多位置测量 方向误差；距离 2 m 至 10 m 0 mm 至 0,2 mm CMC 10 µm KP7 – TRAKČNÍ LASER 2; ČSN EN ISO 10 360-10; EN ISO 10 360-10","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1e6619d0e861e5a65b1d296d","lab_id":"6ade8b4cff06824761708139","country":"CZ","accr_number":"2397","accr_body":"ČIA","row_label":"4","test_object":"Trackery laserowe","test_object_en":"Laser trackers","test_object_zh":"激光跟踪仪","test_object_cs":"Trakční lasery","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"Przesunięcie (offset) odległości; odległość 1,5 m do 15 m","range":"od -2,0 mm do 2,0 mm","cmc":"7 µm"}],"parameters_en":[{"name":"Distance offset; length 1,5 m to 15 m","range":"-2,0 mm to 2,0 mm","cmc":"7 µm"}],"parameters_zh":[{"name":"距离偏移；距离 1,5 m 至 15 m","range":"-2,0 mm 至 2,0 mm","cmc":"7 µm"}],"parameters_cs":[{"name":"Offset vzdálenosti; vzdálenost 1,5 m až 15 m","range":"-2,0 mm až 2,0 mm","cmc":"7 µm"}],"technique":"Pomiar procedurą samowzorcowania","technique_en":"Measurement by self-calibration procedure","technique_zh":"用自校准程序测量","technique_cs":"Měření samokalibračním postupem","techniques":["Pomiar procedurą samowzorcowania"],"techniques_en":["Measurement by self-calibration procedure"],"techniques_zh":["用自校准程序测量"],"techniques_cs":["Měření samokalibračním postupem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nPrzesunięcie (offset) odległości; odległość 1,5 m do 15 m od -2,0 mm do 2,0 mm CMC 7 µm\nPomiar procedurą samowzorcowania","reference":"KP6 – TRAKČNÍ LASER 1; KP7 – TRAKČNÍ LASER 2; ČSN EN ISO 10 360-10; EN ISO 10 360-10","norm_bases":["KP6 – TRAKČNÍ LASER 1","KP7 – TRAKČNÍ LASER 2","ČSN EN ISO 10 360-10","EN ISO 10 360-10"],"lab_section":"Pracownia Praga","lab_section_en":"Workplace Prague","lab_section_zh":"布拉格工作场所","lab_section_cs":"Pracoviště Praha","lab_address":"Boudníkova 2538/13, Libeň, 180 00 Praha 8","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Trackery laserowe Wzorcowanie – długość Pomiar procedurą samowzorcowania Przesunięcie (offset) odległości; odległość 1,5 m do 15 m od -2,0 mm do 2,0 mm CMC 7 µm Trakční lasery Kalibrace – délka Měření samokalibračním postupem Offset vzdálenosti; vzdálenost 1,5 m až 15 m -2,0 mm až 2,0 mm CMC 7 µm KP6 – TRAKČNÍ LASER 1; KP7 – TRAKČNÍ LASER 2; ČSN EN ISO 10 360-10; EN ISO 10 360-10 Trackery laserowe Wzorcowanie – dlugosc Pomiar procedura samowzorcowania Przesuniecie (offset) odleglosci; odleglosc 1,5 m do 15 m od -2,0 mm do 2,0 mm CMC 7 µm Trakcni lasery Kalibrace – delka Mereni samokalibracnim postupem Offset vzdalenosti; vzdalenost 1,5 m az 15 m -2,0 mm az 2,0 mm CMC 7 µm KP6 – TRAKCNI LASER 1; KP7 – TRAKCNI LASER 2; CSN EN ISO 10 360-10; EN ISO 10 360-10","search_en":"Laser trackers Calibration – length Measurement by self-calibration procedure Distance offset; length 1,5 m to 15 m -2,0 mm to 2,0 mm CMC 7 µm KP6 – TRAKČNÍ LASER 1; KP7 – TRAKČNÍ LASER 2; ČSN EN ISO 10 360-10; EN ISO 10 360-10","search_zh":"激光跟踪仪 校准 – 长度 用自校准程序测量 距离偏移；距离 1,5 m 至 15 m -2,0 mm 至 2,0 mm CMC 7 µm KP6 – TRAKČNÍ LASER 1; KP7 – TRAKČNÍ LASER 2; ČSN EN ISO 10 360-10; EN ISO 10 360-10","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a96ae89fe4d7c263baabf026","lab_id":"6ade8b4cff06824761708139","country":"CZ","accr_number":"2397","accr_body":"ČIA","row_label":"4","test_object":"Trackery laserowe","test_object_en":"Laser trackers","test_object_zh":"激光跟踪仪","test_object_cs":"Trakční lasery","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"Częstotliwość modulacji miernika odległości bezwzględnej","range":"od 0 kHz do 25 MHz","cmc":"0,75 Hz"}],"parameters_en":[{"name":"Absolute distance meter modulation frequency","range":"0 kHz to 25 MHz","cmc":"0,75 Hz"}],"parameters_zh":[{"name":"绝对测距仪调制频率","range":"0 kHz 至 25 MHz","cmc":"0,75 Hz"}],"parameters_cs":[{"name":"Modulační frekvence měřiče absolutní vzdálenosti","range":"0 kHz až 25 MHz","cmc":"0,75 Hz"}],"technique":"Pomiar rubidowym wzorcem częstotliwości","technique_en":"Rubidium frequency standard measurement","technique_zh":"用铷频率标准测量","technique_cs":"Měření rubidiovým frekvenčním etalonem","techniques":["Pomiar rubidowym wzorcem częstotliwości"],"techniques_en":["Rubidium frequency standard measurement"],"techniques_zh":["用铷频率标准测量"],"techniques_cs":["Měření rubidiovým frekvenčním etalonem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nCzęstotliwość modulacji miernika odległości bezwzględnej od 0 kHz do 25 MHz CMC 0,75 Hz\nPomiar rubidowym wzorcem częstotliwości","reference":"KP6 – TRAKČNÍ LASER 1; KP7 – TRAKČNÍ LASER 2; ČSN EN ISO 10 360-10; EN ISO 10 360-10","norm_bases":["KP6 – TRAKČNÍ LASER 1","KP7 – TRAKČNÍ LASER 2","ČSN EN ISO 10 360-10","EN ISO 10 360-10"],"lab_section":"Pracownia Praga","lab_section_en":"Workplace Prague","lab_section_zh":"布拉格工作场所","lab_section_cs":"Pracoviště Praha","lab_address":"Boudníkova 2538/13, Libeň, 180 00 Praha 8","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Trackery laserowe Wzorcowanie – długość Pomiar rubidowym wzorcem częstotliwości Częstotliwość modulacji miernika odległości bezwzględnej od 0 kHz do 25 MHz CMC 0,75 Hz Trakční lasery Kalibrace – délka Měření rubidiovým frekvenčním etalonem Modulační frekvence měřiče absolutní vzdálenosti 0 kHz až 25 MHz CMC 0,75 Hz KP6 – TRAKČNÍ LASER 1; KP7 – TRAKČNÍ LASER 2; ČSN EN ISO 10 360-10; EN ISO 10 360-10 Trackery laserowe Wzorcowanie – dlugosc Pomiar rubidowym wzorcem czestotliwosci Czestotliwosc modulacji miernika odleglosci bezwzglednej od 0 kHz do 25 MHz CMC 0,75 Hz Trakcni lasery Kalibrace – delka Mereni rubidiovym frekvencnim etalonem Modulacni frekvence merice absolutni vzdalenosti 0 kHz az 25 MHz CMC 0,75 Hz KP6 – TRAKCNI LASER 1; KP7 – TRAKCNI LASER 2; CSN EN ISO 10 360-10; EN ISO 10 360-10","search_en":"Laser trackers Calibration – length Rubidium frequency standard measurement Absolute distance meter modulation frequency 0 kHz to 25 MHz CMC 0,75 Hz KP6 – TRAKČNÍ LASER 1; KP7 – TRAKČNÍ LASER 2; ČSN EN ISO 10 360-10; EN ISO 10 360-10","search_zh":"激光跟踪仪 校准 – 长度 用铷频率标准测量 绝对测距仪调制频率 0 kHz 至 25 MHz CMC 0,75 Hz KP6 – TRAKČNÍ LASER 1; KP7 – TRAKČNÍ LASER 2; ČSN EN ISO 10 360-10; EN ISO 10 360-10","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}