{"lab":{"_id":"6ade8b4aff06824761708137","country":"CZ","accr_number":"2394","accr_body":"ČIA","address":"č.p. 8, 769 01 Třebětice","categories":["metrology"],"city":"Třebětice","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[17.5196244,49.3195781]},"map_coord":[49.3195781,17.5196244],"map_geo":"cai-mapa","methods_count":20,"name":"KALIST AKL s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinach: objętość, masa, prędkość obrotowa, temperatura, wilgotność powietrza, czas i częstotliwość, w zakresie określonym w załączniku do świadectwa.","search_text":"kalist akl s.r.o. č.p. 8, 769 01 třebětice 2394","source_page_url":"https://www.cai.cz/?subjekt=2394-kalist-akl-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"04-09-2030","website":"www.kalist.cz","certificate_date":"04.09.2025","certificate_no":"451/2025","certificate_replaces":"310/2023 z 15.06.2023","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinach: objętość, masa, prędkość obrotowa, temperatura, wilgotność powietrza, czas i częstotliwość, w zakresie określonym w załączniku do świadectwa.","en":"Calibration in the fields of volume, mass, rotational speed, temperature, air humidity, time, and frequency to the extent as specified in the appendix to this Certificate.","zh":"体积、质量、转速、温度、空气湿度、时间和频率领域的校准，范围见本证书附件。","cs":"Kalibrace v oborech objem, hmotnost, otáčky, teplota, vlhkost vzduchu, čas a frekvence, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące","lab_division_cs":"Kalibrační laboratoř","lab_division_en":"Calibration Laboratory","lab_division_zh":"校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"a949f78bf774adf0dcf818ab6241aa4901b7c68750336f30e2ad3a33974d47ff","source_pdf_url":"https://www.cai.cz/OA/pdf/451_2025_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/451_2025_EN.pdf"},"methods":[{"_id":"0fc5361bdc7dae3b3093417d","lab_id":"6ade8b4aff06824761708137","country":"CZ","accr_number":"2394","accr_body":"ČIA","row_label":"1","test_object":"Pipety tłokowe","test_object_en":"Piston pipettes","test_object_zh":"活塞式移液器","test_object_cs":"Pístové pipety","methodology":"Wzorcowanie – objętość","methodology_en":"Calibration – volume","methodology_zh":"校准 – 体积","methodology_cs":"Kalibrace – objem","parameters":[{"name":"","range":"od 0,5 µl do 10000 µl","cmc":"0,13 % + 0,01 µl"}],"parameters_en":[{"name":"","range":"0,5 µl to 10000 µl","cmc":"0,13 % + 0,01 µl"}],"parameters_zh":[{"name":"","range":"0,5 µl 至 10000 µl","cmc":"0,13 % + 0,01 µl"}],"parameters_cs":[{"name":"","range":"0,5 µl až 10000 µl","cmc":"0,13 % + 0,01 µl"}],"technique":"Metoda grawimetryczna (ČSN EN ISO 8655-6; EURAMET cg-19)","technique_en":"Gravimetric method (ČSN EN ISO 8655-6; EURAMET cg-19)","technique_zh":"称量法（ČSN EN ISO 8655-6；EURAMET cg-19）","technique_cs":"Gravimetrická metoda (ČSN EN ISO 8655-6; EURAMET cg-19)","techniques":["Metoda grawimetryczna (ČSN EN ISO 8655-6; EURAMET cg-19)"],"techniques_en":["Gravimetric method (ČSN EN ISO 8655-6; EURAMET cg-19)"],"techniques_zh":["称量法（ČSN EN ISO 8655-6；EURAMET cg-19）"],"techniques_cs":["Gravimetrická metoda (ČSN EN ISO 8655-6; EURAMET cg-19)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – objętość\nod 0,5 µl do 10000 µl CMC 0,13 % + 0,01 µl\nMetoda grawimetryczna (ČSN EN ISO 8655-6; EURAMET cg-19)","reference":"KP-05","norm_bases":["KP-05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: objętość","regulatory_area_en":"CMC for the field of measured quantity: Volume","regulatory_area_zh":"被测量领域的CMC：体积","regulatory_area_cs":"CMC pro obor měřené veličiny: Objem","flexible":false,"flexibility":null,"outside_premises":false,"note":"Najmniejsza podawana niepewność obejmuje wpływ operatora; nie uwzględniono statystycznej składowej niepewności.","note_en":"The lowest uncertainty includes the effect of the operator and does not include the statistical components of uncertainty.","note_zh":"所给最小不确定度包含操作者的影响，未计入不确定度的统计分量。","note_cs":"V nejnižší udávané nejistotě je zahrnut vliv operátora, není započtena statistická složka nejistoty.","search_text":"Pipety tłokowe Wzorcowanie – objętość Metoda grawimetryczna (ČSN EN ISO 8655-6; EURAMET cg-19) od 0,5 µl do 10000 µl CMC 0,13 % + 0,01 µl Pístové pipety Kalibrace – objem Gravimetrická metoda (ČSN EN ISO 8655-6; EURAMET cg-19) 0,5 µl až 10000 µl CMC 0,13 % + 0,01 µl KP-05 Pipety tlokowe Wzorcowanie – objetosc Metoda grawimetryczna (CSN EN ISO 8655-6; EURAMET cg-19) od 0,5 µl do 10000 µl CMC 0,13 % + 0,01 µl Pistove pipety Kalibrace – objem Gravimetricka metoda (CSN EN ISO 8655-6; EURAMET cg-19) 0,5 µl az 10000 µl CMC 0,13 % + 0,01 µl KP-05","search_en":"Piston pipettes Calibration – volume Gravimetric method (ČSN EN ISO 8655-6; EURAMET cg-19) 0,5 µl to 10000 µl CMC 0,13 % + 0,01 µl KP-05","search_zh":"活塞式移液器 校准 – 体积 称量法（ČSN EN ISO 8655-6；EURAMET cg-19） 0,5 µl 至 10000 µl CMC 0,13 % + 0,01 µl KP-05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1750d762a569d116819c03f3","lab_id":"6ade8b4aff06824761708137","country":"CZ","accr_number":"2394","accr_body":"ČIA","row_label":"1","test_object":"Pozostałe przyrządy tłokowe – biurety, dozowniki, urządzenia do rozcieńczania","test_object_en":"Other piston gauges – burettes, dispensers, dilution devices","test_object_zh":"其他活塞式量器 – 滴定管、分液器、稀释装置","test_object_cs":"Ostatní pístová měřidla – byrety, dávkovače, zařízení ke zřeďování","methodology":"Wzorcowanie – objętość","methodology_en":"Calibration – volume","methodology_zh":"校准 – 体积","methodology_cs":"Kalibrace – objem","parameters":[{"name":"","range":"od 0,1 ml do 100 ml","cmc":"0,05 %"}],"parameters_en":[{"name":"","range":"0,1 ml to 100 ml","cmc":"0,05 %"}],"parameters_zh":[{"name":"","range":"0,1 ml 至 100 ml","cmc":"0,05 %"}],"parameters_cs":[{"name":"","range":"0,1 ml až 100 ml","cmc":"0,05 %"}],"technique":"Metoda grawimetryczna (ČSN EN ISO 8655-6; EURAMET cg-19)","technique_en":"Gravimetric method (ČSN EN ISO 8655-6; EURAMET cg-19)","technique_zh":"称量法（ČSN EN ISO 8655-6；EURAMET cg-19）","technique_cs":"Gravimetrická metoda (ČSN EN ISO 8655-6; EURAMET cg-19)","techniques":["Metoda grawimetryczna (ČSN EN ISO 8655-6; EURAMET cg-19)"],"techniques_en":["Gravimetric method (ČSN EN ISO 8655-6; EURAMET cg-19)"],"techniques_zh":["称量法（ČSN EN ISO 8655-6；EURAMET cg-19）"],"techniques_cs":["Gravimetrická metoda (ČSN EN ISO 8655-6; EURAMET cg-19)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – objętość\nod 0,1 ml do 100 ml CMC 0,05 %\nMetoda grawimetryczna (ČSN EN ISO 8655-6; EURAMET cg-19)","reference":"KP-05","norm_bases":["KP-05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: objętość","regulatory_area_en":"CMC for the field of measured quantity: Volume","regulatory_area_zh":"被测量领域的CMC：体积","regulatory_area_cs":"CMC pro obor měřené veličiny: Objem","flexible":false,"flexibility":null,"outside_premises":false,"note":"Najmniejsza podawana niepewność obejmuje wpływ operatora; nie uwzględniono statystycznej składowej niepewności.","note_en":"The lowest uncertainty includes the effect of the operator and does not include the statistical components of uncertainty.","note_zh":"所给最小不确定度包含操作者的影响，未计入不确定度的统计分量。","note_cs":"V nejnižší udávané nejistotě je zahrnut vliv operátora, není započtena statistická složka nejistoty.","search_text":"Pozostałe przyrządy tłokowe – biurety, dozowniki, urządzenia do rozcieńczania Wzorcowanie – objętość Metoda grawimetryczna (ČSN EN ISO 8655-6; EURAMET cg-19) od 0,1 ml do 100 ml CMC 0,05 % Ostatní pístová měřidla – byrety, dávkovače, zařízení ke zřeďování Kalibrace – objem Gravimetrická metoda (ČSN EN ISO 8655-6; EURAMET cg-19) 0,1 ml až 100 ml CMC 0,05 % KP-05 Pozostale przyrzady tlokowe – biurety, dozowniki, urzadzenia do rozcienczania Wzorcowanie – objetosc Metoda grawimetryczna (CSN EN ISO 8655-6; EURAMET cg-19) od 0,1 ml do 100 ml CMC 0,05 % Ostatni pistova meridla – byrety, davkovace, zarizeni ke zredovani Kalibrace – objem Gravimetricka metoda (CSN EN ISO 8655-6; EURAMET cg-19) 0,1 ml az 100 ml CMC 0,05 % KP-05","search_en":"Other piston gauges – burettes, dispensers, dilution devices Calibration – volume Gravimetric method (ČSN EN ISO 8655-6; EURAMET cg-19) 0,1 ml to 100 ml CMC 0,05 % KP-05","search_zh":"其他活塞式量器 – 滴定管、分液器、稀释装置 校准 – 体积 称量法（ČSN EN ISO 8655-6；EURAMET cg-19） 0,1 ml 至 100 ml CMC 0,05 % KP-05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e73502bc3bb36effc2609412","lab_id":"6ade8b4aff06824761708137","country":"CZ","accr_number":"2394","accr_body":"ČIA","row_label":"1","test_object":"Wagi nieautomatyczne","test_object_en":"Balances with non-automatic function","test_object_zh":"非自动衡器","test_object_cs":"Váhy s neautomatickou činností","methodology":"Wzorcowanie – masa","methodology_en":"Calibration – mass","methodology_zh":"校准 – 质量","methodology_cs":"Kalibrace – hmotnost","parameters":[{"name":"","range":"0 g","cmc":"0,0006 mg"}],"parameters_en":[{"name":"","range":"0 g","cmc":"0,0006 mg"}],"parameters_zh":[{"name":"","range":"0 g","cmc":"0,0006 mg"}],"parameters_cs":[{"name":"","range":"0 g","cmc":"0,0006 mg"}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – masa\n0 g CMC 0,0006 mg","reference":"KP-01","norm_bases":["KP-01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: masa","regulatory_area_en":"CMC for the field of measured quantity: Mass","regulatory_area_zh":"被测量领域的CMC：质量","regulatory_area_cs":"CMC pro obor měřené veličiny: Hmotnost","flexible":false,"flexibility":null,"outside_premises":true,"note":"Odważnikom o indywidualnej wartości nominalnej leżącej między wartościami zdefiniowanymi przypisuje się niepewność bezpośrednio wyższą.","note_en":"Weights with an individual nominal value lying between the defined values are assigned the next higher uncertainty.","note_zh":"对于标称值介于规定值之间的单个砝码，取紧邻较高的不确定度。","note_cs":"U závaží s individuální jmenovitou hodnotou ležící mezi definovanými hodnotami je přiřazena nejistota bezprostředně vyšší.","search_text":"Wagi nieautomatyczne Wzorcowanie – masa 0 g CMC 0,0006 mg Váhy s neautomatickou činností Kalibrace – hmotnost 0 g CMC 0,0006 mg KP-01 Wagi nieautomatyczne Wzorcowanie – masa 0 g CMC 0,0006 mg Vahy s neautomatickou cinnosti Kalibrace – hmotnost 0 g CMC 0,0006 mg KP-01","search_en":"Balances with non-automatic function Calibration – mass 0 g CMC 0,0006 mg KP-01","search_zh":"非自动衡器 校准 – 质量 0 g CMC 0,0006 mg KP-01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8b8e67e8259d3456033e713e","lab_id":"6ade8b4aff06824761708137","country":"CZ","accr_number":"2394","accr_body":"ČIA","row_label":"1","test_object":"Wagi nieautomatyczne","test_object_en":"Balances with non-automatic function","test_object_zh":"非自动衡器","test_object_cs":"Váhy s neautomatickou činností","methodology":"Wzorcowanie – masa","methodology_en":"Calibration – mass","methodology_zh":"校准 – 质量","methodology_cs":"Kalibrace – hmotnost","parameters":[{"name":"","range":"od 1 mg do 50 mg","cmc":"0,005 mg"},{"name":"","range":"od 50 mg do 500 mg","cmc":"0,009 mg"},{"name":"","range":"od 500 mg do 1 g","cmc":"0,011 mg"},{"name":"","range":"od 1 g do 2 g","cmc":"0,014 mg"},{"name":"","range":"od 2 g do 5 g","cmc":"0,017 mg"},{"name":"","range":"od 5 g do 10 g","cmc":"0,021 mg"},{"name":"","range":"od 10 g do 20 g","cmc":"0,027 mg"},{"name":"","range":"od 20 g do 50 g","cmc":"0,034 mg"},{"name":"","range":"od 50 g do 66 kg","cmc":"5·10⁻⁷"}],"parameters_en":[{"name":"","range":"1 mg to 50 mg","cmc":"0,005 mg"},{"name":"","range":"50 mg to 500 mg","cmc":"0,009 mg"},{"name":"","range":"500 mg to 1 g","cmc":"0,011 mg"},{"name":"","range":"1 g to 2 g","cmc":"0,014 mg"},{"name":"","range":"2 g to 5 g","cmc":"0,017 mg"},{"name":"","range":"5 g to 10 g","cmc":"0,021 mg"},{"name":"","range":"10 g to 20 g","cmc":"0,027 mg"},{"name":"","range":"20 g to 50 g","cmc":"0,034 mg"},{"name":"","range":"50 g to 66 kg","cmc":"5·10⁻⁷"}],"parameters_zh":[{"name":"","range":"1 mg 至 50 mg","cmc":"0,005 mg"},{"name":"","range":"50 mg 至 500 mg","cmc":"0,009 mg"},{"name":"","range":"500 mg 至 1 g","cmc":"0,011 mg"},{"name":"","range":"1 g 至 2 g","cmc":"0,014 mg"},{"name":"","range":"2 g 至 5 g","cmc":"0,017 mg"},{"name":"","range":"5 g 至 10 g","cmc":"0,021 mg"},{"name":"","range":"10 g 至 20 g","cmc":"0,027 mg"},{"name":"","range":"20 g 至 50 g","cmc":"0,034 mg"},{"name":"","range":"50 g 至 66 kg","cmc":"5·10⁻⁷"}],"parameters_cs":[{"name":"","range":"1 mg až 50 mg","cmc":"0,005 mg"},{"name":"","range":"50 mg až 500 mg","cmc":"0,009 mg"},{"name":"","range":"500 mg až 1 g","cmc":"0,011 mg"},{"name":"","range":"1 g až 2 g","cmc":"0,014 mg"},{"name":"","range":"2 g až 5 g","cmc":"0,017 mg"},{"name":"","range":"5 g až 10 g","cmc":"0,021 mg"},{"name":"","range":"10 g až 20 g","cmc":"0,027 mg"},{"name":"","range":"20 g až 50 g","cmc":"0,034 mg"},{"name":"","range":"50 g až 66 kg","cmc":"5·10⁻⁷"}],"technique":"Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy E2","technique_en":"Loading using a class E2 reference weight (according to OIML R111-1:2004)","technique_zh":"用 E2 级标准砝码（按 OIML R111-1:2004）加载","technique_cs":"Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy E2","techniques":["Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy E2"],"techniques_en":["Loading using a class E2 reference weight (according to OIML R111-1:2004)"],"techniques_zh":["用 E2 级标准砝码（按 OIML R111-1:2004）加载"],"techniques_cs":["Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy E2"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – masa\nZakres:\nod 1 mg do 50 mg CMC 0,005 mg\nod 50 mg do 500 mg CMC 0,009 mg\nod 500 mg do 1 g CMC 0,011 mg\nod 1 g do 2 g CMC 0,014 mg\nod 2 g do 5 g CMC 0,017 mg\nod 5 g do 10 g CMC 0,021 mg\nod 10 g do 20 g CMC 0,027 mg\nod 20 g do 50 g CMC 0,034 mg\nod 50 g do 66 kg CMC 5·10⁻⁷\nObciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy E2","reference":"KP-01","norm_bases":["KP-01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: masa","regulatory_area_en":"CMC for the field of measured quantity: Mass","regulatory_area_zh":"被测量领域的CMC：质量","regulatory_area_cs":"CMC pro obor měřené veličiny: Hmotnost","flexible":false,"flexibility":null,"outside_premises":true,"note":"Odważnikom o indywidualnej wartości nominalnej leżącej między wartościami zdefiniowanymi przypisuje się niepewność bezpośrednio wyższą.","note_en":"Weights with an individual nominal value lying between the defined values are assigned the next higher uncertainty.","note_zh":"对于标称值介于规定值之间的单个砝码，取紧邻较高的不确定度。","note_cs":"U závaží s individuální jmenovitou hodnotou ležící mezi definovanými hodnotami je přiřazena nejistota bezprostředně vyšší.","search_text":"Wagi nieautomatyczne Wzorcowanie – masa Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy E2 od 1 mg do 50 mg CMC 0,005 mg od 50 mg do 500 mg CMC 0,009 mg od 500 mg do 1 g CMC 0,011 mg od 1 g do 2 g CMC 0,014 mg od 2 g do 5 g CMC 0,017 mg od 5 g do 10 g CMC 0,021 mg od 10 g do 20 g CMC 0,027 mg od 20 g do 50 g CMC 0,034 mg od 50 g do 66 kg CMC 5·10⁻⁷ Váhy s neautomatickou činností Kalibrace – hmotnost Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy E2 1 mg až 50 mg CMC 0,005 mg 50 mg až 500 mg CMC 0,009 mg 500 mg až 1 g CMC 0,011 mg 1 g až 2 g CMC 0,014 mg 2 g až 5 g CMC 0,017 mg 5 g až 10 g CMC 0,021 mg 10 g až 20 g CMC 0,027 mg 20 g až 50 g CMC 0,034 mg 50 g až 66 kg CMC 5·10⁻⁷ KP-01 Wagi nieautomatyczne Wzorcowanie – masa Obciazenie odwaznikiem wzorcowym (wg OIML R111-1:2004) klasy E2 od 1 mg do 50 mg CMC 0,005 mg od 50 mg do 500 mg CMC 0,009 mg od 500 mg do 1 g CMC 0,011 mg od 1 g do 2 g CMC 0,014 mg od 2 g do 5 g CMC 0,017 mg od 5 g do 10 g CMC 0,021 mg od 10 g do 20 g CMC 0,027 mg od 20 g do 50 g CMC 0,034 mg od 50 g do 66 kg CMC 5·10⁻⁷ Vahy s neautomatickou cinnosti Kalibrace – hmotnost Zatizeni etalonovym zavazim (dle OIML R111-1:2004) tridy E2 1 mg az 50 mg CMC 0,005 mg 50 mg az 500 mg CMC 0,009 mg 500 mg az 1 g CMC 0,011 mg 1 g az 2 g CMC 0,014 mg 2 g az 5 g CMC 0,017 mg 5 g az 10 g CMC 0,021 mg 10 g az 20 g CMC 0,027 mg 20 g az 50 g CMC 0,034 mg 50 g az 66 kg CMC 5·10⁻⁷ KP-01","search_en":"Balances with non-automatic function Calibration – mass Loading using a class E2 reference weight (according to OIML R111-1:2004) 1 mg to 50 mg CMC 0,005 mg 50 mg to 500 mg CMC 0,009 mg 500 mg to 1 g CMC 0,011 mg 1 g to 2 g CMC 0,014 mg 2 g to 5 g CMC 0,017 mg 5 g to 10 g CMC 0,021 mg 10 g to 20 g CMC 0,027 mg 20 g to 50 g CMC 0,034 mg 50 g to 66 kg CMC 5·10⁻⁷ KP-01","search_zh":"非自动衡器 校准 – 质量 用 E2 级标准砝码（按 OIML R111-1:2004）加载 1 mg 至 50 mg CMC 0,005 mg 50 mg 至 500 mg CMC 0,009 mg 500 mg 至 1 g CMC 0,011 mg 1 g 至 2 g CMC 0,014 mg 2 g 至 5 g CMC 0,017 mg 5 g 至 10 g CMC 0,021 mg 10 g 至 20 g CMC 0,027 mg 20 g 至 50 g CMC 0,034 mg 50 g 至 66 kg CMC 5·10⁻⁷ KP-01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d776ab9342d9493d95398728","lab_id":"6ade8b4aff06824761708137","country":"CZ","accr_number":"2394","accr_body":"ČIA","row_label":"1","test_object":"Wagi nieautomatyczne","test_object_en":"Balances with non-automatic function","test_object_zh":"非自动衡器","test_object_cs":"Váhy s neautomatickou činností","methodology":"Wzorcowanie – masa","methodology_en":"Calibration – mass","methodology_zh":"校准 – 质量","methodology_cs":"Kalibrace – hmotnost","parameters":[{"name":"","range":"od 1 mg do 5 g","cmc":"0,1 mg"},{"name":"","range":"od 5 g do 50 g","cmc":"0,2 mg"},{"name":"","range":"od 50 g do 16 kg","cmc":"4·10⁻⁶"}],"parameters_en":[{"name":"","range":"1 mg to 5 g","cmc":"0,1 mg"},{"name":"","range":"5 g to 50 g","cmc":"0,2 mg"},{"name":"","range":"50 g to 16 kg","cmc":"4·10⁻⁶"}],"parameters_zh":[{"name":"","range":"1 mg 至 5 g","cmc":"0,1 mg"},{"name":"","range":"5 g 至 50 g","cmc":"0,2 mg"},{"name":"","range":"50 g 至 16 kg","cmc":"4·10⁻⁶"}],"parameters_cs":[{"name":"","range":"1 mg až 5 g","cmc":"0,1 mg"},{"name":"","range":"5 g až 50 g","cmc":"0,2 mg"},{"name":"","range":"50 g až 16 kg","cmc":"4·10⁻⁶"}],"technique":"Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy F1","technique_en":"Loading using a class F1 reference weight (according to OIML R111-1:2004)","technique_zh":"用 F1 级标准砝码（按 OIML R111-1:2004）加载","technique_cs":"Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy F1","techniques":["Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy F1"],"techniques_en":["Loading using a class F1 reference weight (according to OIML R111-1:2004)"],"techniques_zh":["用 F1 级标准砝码（按 OIML R111-1:2004）加载"],"techniques_cs":["Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy F1"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – masa\nZakres:\nod 1 mg do 5 g CMC 0,1 mg\nod 5 g do 50 g CMC 0,2 mg\nod 50 g do 16 kg CMC 4·10⁻⁶\nObciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy F1","reference":"KP-01","norm_bases":["KP-01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: masa","regulatory_area_en":"CMC for the field of measured quantity: Mass","regulatory_area_zh":"被测量领域的CMC：质量","regulatory_area_cs":"CMC pro obor měřené veličiny: Hmotnost","flexible":false,"flexibility":null,"outside_premises":true,"note":"Odważnikom o indywidualnej wartości nominalnej leżącej między wartościami zdefiniowanymi przypisuje się niepewność bezpośrednio wyższą.","note_en":"Weights with an individual nominal value lying between the defined values are assigned the next higher uncertainty.","note_zh":"对于标称值介于规定值之间的单个砝码，取紧邻较高的不确定度。","note_cs":"U závaží s individuální jmenovitou hodnotou ležící mezi definovanými hodnotami je přiřazena nejistota bezprostředně vyšší.","search_text":"Wagi nieautomatyczne Wzorcowanie – masa Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy F1 od 1 mg do 5 g CMC 0,1 mg od 5 g do 50 g CMC 0,2 mg od 50 g do 16 kg CMC 4·10⁻⁶ Váhy s neautomatickou činností Kalibrace – hmotnost Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy F1 1 mg až 5 g CMC 0,1 mg 5 g až 50 g CMC 0,2 mg 50 g až 16 kg CMC 4·10⁻⁶ KP-01 Wagi nieautomatyczne Wzorcowanie – masa Obciazenie odwaznikiem wzorcowym (wg OIML R111-1:2004) klasy F1 od 1 mg do 5 g CMC 0,1 mg od 5 g do 50 g CMC 0,2 mg od 50 g do 16 kg CMC 4·10⁻⁶ Vahy s neautomatickou cinnosti Kalibrace – hmotnost Zatizeni etalonovym zavazim (dle OIML R111-1:2004) tridy F1 1 mg az 5 g CMC 0,1 mg 5 g az 50 g CMC 0,2 mg 50 g az 16 kg CMC 4·10⁻⁶ KP-01","search_en":"Balances with non-automatic function Calibration – mass Loading using a class F1 reference weight (according to OIML R111-1:2004) 1 mg to 5 g CMC 0,1 mg 5 g to 50 g CMC 0,2 mg 50 g to 16 kg CMC 4·10⁻⁶ KP-01","search_zh":"非自动衡器 校准 – 质量 用 F1 级标准砝码（按 OIML R111-1:2004）加载 1 mg 至 5 g CMC 0,1 mg 5 g 至 50 g CMC 0,2 mg 50 g 至 16 kg CMC 4·10⁻⁶ KP-01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"57aecd4a0c47d4acc93330ff","lab_id":"6ade8b4aff06824761708137","country":"CZ","accr_number":"2394","accr_body":"ČIA","row_label":"1","test_object":"Wagi nieautomatyczne","test_object_en":"Balances with non-automatic function","test_object_zh":"非自动衡器","test_object_cs":"Váhy s neautomatickou činností","methodology":"Wzorcowanie – masa","methodology_en":"Calibration – mass","methodology_zh":"校准 – 质量","methodology_cs":"Kalibrace – hmotnost","parameters":[{"name":"","range":"od 1 g do 50 g","cmc":"1 mg"},{"name":"","range":"od 50 g do 370 kg","cmc":"1·10⁻⁵"}],"parameters_en":[{"name":"","range":"1 g to 50 g","cmc":"1 mg"},{"name":"","range":"50 g to 370 kg","cmc":"1·10⁻⁵"}],"parameters_zh":[{"name":"","range":"1 g 至 50 g","cmc":"1 mg"},{"name":"","range":"50 g 至 370 kg","cmc":"1·10⁻⁵"}],"parameters_cs":[{"name":"","range":"1 g až 50 g","cmc":"1 mg"},{"name":"","range":"50 g až 370 kg","cmc":"1·10⁻⁵"}],"technique":"Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy F2","technique_en":"Loading using a class F2 reference weight (according to OIML R111-1:2004)","technique_zh":"用 F2 级标准砝码（按 OIML R111-1:2004）加载","technique_cs":"Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy F2","techniques":["Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy F2"],"techniques_en":["Loading using a class F2 reference weight (according to OIML R111-1:2004)"],"techniques_zh":["用 F2 级标准砝码（按 OIML R111-1:2004）加载"],"techniques_cs":["Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy F2"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – masa\nZakres:\nod 1 g do 50 g CMC 1 mg\nod 50 g do 370 kg CMC 1·10⁻⁵\nObciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy F2","reference":"KP-01","norm_bases":["KP-01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: masa","regulatory_area_en":"CMC for the field of measured quantity: Mass","regulatory_area_zh":"被测量领域的CMC：质量","regulatory_area_cs":"CMC pro obor měřené veličiny: Hmotnost","flexible":false,"flexibility":null,"outside_premises":true,"note":"Odważnikom o indywidualnej wartości nominalnej leżącej między wartościami zdefiniowanymi przypisuje się niepewność bezpośrednio wyższą.","note_en":"Weights with an individual nominal value lying between the defined values are assigned the next higher uncertainty.","note_zh":"对于标称值介于规定值之间的单个砝码，取紧邻较高的不确定度。","note_cs":"U závaží s individuální jmenovitou hodnotou ležící mezi definovanými hodnotami je přiřazena nejistota bezprostředně vyšší.","search_text":"Wagi nieautomatyczne Wzorcowanie – masa Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy F2 od 1 g do 50 g CMC 1 mg od 50 g do 370 kg CMC 1·10⁻⁵ Váhy s neautomatickou činností Kalibrace – hmotnost Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy F2 1 g až 50 g CMC 1 mg 50 g až 370 kg CMC 1·10⁻⁵ KP-01 Wagi nieautomatyczne Wzorcowanie – masa Obciazenie odwaznikiem wzorcowym (wg OIML R111-1:2004) klasy F2 od 1 g do 50 g CMC 1 mg od 50 g do 370 kg CMC 1·10⁻⁵ Vahy s neautomatickou cinnosti Kalibrace – hmotnost Zatizeni etalonovym zavazim (dle OIML R111-1:2004) tridy F2 1 g az 50 g CMC 1 mg 50 g az 370 kg CMC 1·10⁻⁵ KP-01","search_en":"Balances with non-automatic function Calibration – mass Loading using a class F2 reference weight (according to OIML R111-1:2004) 1 g to 50 g CMC 1 mg 50 g to 370 kg CMC 1·10⁻⁵ KP-01","search_zh":"非自动衡器 校准 – 质量 用 F2 级标准砝码（按 OIML R111-1:2004）加载 1 g 至 50 g CMC 1 mg 50 g 至 370 kg CMC 1·10⁻⁵ KP-01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"014cacdbc2f9abdf634570ea","lab_id":"6ade8b4aff06824761708137","country":"CZ","accr_number":"2394","accr_body":"ČIA","row_label":"1","test_object":"Wagi nieautomatyczne","test_object_en":"Balances with non-automatic function","test_object_zh":"非自动衡器","test_object_cs":"Váhy s neautomatickou činností","methodology":"Wzorcowanie – masa","methodology_en":"Calibration – mass","methodology_zh":"校准 – 质量","methodology_cs":"Kalibrace – hmotnost","parameters":[{"name":"","range":"od 200 kg do 1500 kg","cmc":"1,2·10⁻⁵"}],"parameters_en":[{"name":"","range":"200 kg to 1500 kg","cmc":"1,2·10⁻⁵"}],"parameters_zh":[{"name":"","range":"200 kg 至 1500 kg","cmc":"1,2·10⁻⁵"}],"parameters_cs":[{"name":"","range":"200 kg až 1500 kg","cmc":"1,2·10⁻⁵"}],"technique":"Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy F2 z użyciem obciążenia zastępczego","technique_en":"Loading using a class F2 reference weight (according to OIML R111-1:2004) with the use of substitute load","technique_zh":"用 F2 级标准砝码（按 OIML R111-1:2004）加载并采用替代载荷","technique_cs":"Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy F2 s použitím substitučního zatížení","techniques":["Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy F2 z użyciem obciążenia zastępczego"],"techniques_en":["Loading using a class F2 reference weight (according to OIML R111-1:2004) with the use of substitute load"],"techniques_zh":["用 F2 级标准砝码（按 OIML R111-1:2004）加载并采用替代载荷"],"techniques_cs":["Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy F2 s použitím substitučního zatížení"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – masa\nod 200 kg do 1500 kg CMC 1,2·10⁻⁵\nObciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy F2 z użyciem obciążenia zastępczego","reference":"KP-01","norm_bases":["KP-01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: masa","regulatory_area_en":"CMC for the field of measured quantity: Mass","regulatory_area_zh":"被测量领域的CMC：质量","regulatory_area_cs":"CMC pro obor měřené veličiny: Hmotnost","flexible":false,"flexibility":null,"outside_premises":true,"note":"Odważnikom o indywidualnej wartości nominalnej leżącej między wartościami zdefiniowanymi przypisuje się niepewność bezpośrednio wyższą.","note_en":"Weights with an individual nominal value lying between the defined values are assigned the next higher uncertainty.","note_zh":"对于标称值介于规定值之间的单个砝码，取紧邻较高的不确定度。","note_cs":"U závaží s individuální jmenovitou hodnotou ležící mezi definovanými hodnotami je přiřazena nejistota bezprostředně vyšší.","search_text":"Wagi nieautomatyczne Wzorcowanie – masa Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy F2 z użyciem obciążenia zastępczego od 200 kg do 1500 kg CMC 1,2·10⁻⁵ Váhy s neautomatickou činností Kalibrace – hmotnost Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy F2 s použitím substitučního zatížení 200 kg až 1500 kg CMC 1,2·10⁻⁵ KP-01 Wagi nieautomatyczne Wzorcowanie – masa Obciazenie odwaznikiem wzorcowym (wg OIML R111-1:2004) klasy F2 z uzyciem obciazenia zastepczego od 200 kg do 1500 kg CMC 1,2·10⁻⁵ Vahy s neautomatickou cinnosti Kalibrace – hmotnost Zatizeni etalonovym zavazim (dle OIML R111-1:2004) tridy F2 s pouzitim substitucniho zatizeni 200 kg az 1500 kg CMC 1,2·10⁻⁵ KP-01","search_en":"Balances with non-automatic function Calibration – mass Loading using a class F2 reference weight (according to OIML R111-1:2004) with the use of substitute load 200 kg to 1500 kg CMC 1,2·10⁻⁵ KP-01","search_zh":"非自动衡器 校准 – 质量 用 F2 级标准砝码（按 OIML R111-1:2004）加载并采用替代载荷 200 kg 至 1500 kg CMC 1,2·10⁻⁵ KP-01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ad60ee0dd69b97d6dd1e53ab","lab_id":"6ade8b4aff06824761708137","country":"CZ","accr_number":"2394","accr_body":"ČIA","row_label":"1","test_object":"Wagi nieautomatyczne","test_object_en":"Balances with non-automatic function","test_object_zh":"非自动衡器","test_object_cs":"Váhy s neautomatickou činností","methodology":"Wzorcowanie – masa","methodology_en":"Calibration – mass","methodology_zh":"校准 – 质量","methodology_cs":"Kalibrace – hmotnost","parameters":[{"name":"","range":"od 10 kg do 11 t","cmc":"3,2·10⁻⁵"}],"parameters_en":[{"name":"","range":"10 kg to 11 t","cmc":"3,2·10⁻⁵"}],"parameters_zh":[{"name":"","range":"10 kg 至 11 t","cmc":"3,2·10⁻⁵"}],"parameters_cs":[{"name":"","range":"10 kg až 11 t","cmc":"3,2·10⁻⁵"}],"technique":"Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy M1","technique_en":"Loading using a class M1 reference weight (according to OIML R111-1:2004)","technique_zh":"用 M1 级标准砝码（按 OIML R111-1:2004）加载","technique_cs":"Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy M1","techniques":["Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy M1"],"techniques_en":["Loading using a class M1 reference weight (according to OIML R111-1:2004)"],"techniques_zh":["用 M1 级标准砝码（按 OIML R111-1:2004）加载"],"techniques_cs":["Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy M1"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – masa\nod 10 kg do 11 t CMC 3,2·10⁻⁵\nObciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy M1","reference":"KP-01","norm_bases":["KP-01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: masa","regulatory_area_en":"CMC for the field of measured quantity: Mass","regulatory_area_zh":"被测量领域的CMC：质量","regulatory_area_cs":"CMC pro obor měřené veličiny: Hmotnost","flexible":false,"flexibility":null,"outside_premises":true,"note":"Odważnikom o indywidualnej wartości nominalnej leżącej między wartościami zdefiniowanymi przypisuje się niepewność bezpośrednio wyższą.","note_en":"Weights with an individual nominal value lying between the defined values are assigned the next higher uncertainty.","note_zh":"对于标称值介于规定值之间的单个砝码，取紧邻较高的不确定度。","note_cs":"U závaží s individuální jmenovitou hodnotou ležící mezi definovanými hodnotami je přiřazena nejistota bezprostředně vyšší.","search_text":"Wagi nieautomatyczne Wzorcowanie – masa Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy M1 od 10 kg do 11 t CMC 3,2·10⁻⁵ Váhy s neautomatickou činností Kalibrace – hmotnost Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy M1 10 kg až 11 t CMC 3,2·10⁻⁵ KP-01 Wagi nieautomatyczne Wzorcowanie – masa Obciazenie odwaznikiem wzorcowym (wg OIML R111-1:2004) klasy M1 od 10 kg do 11 t CMC 3,2·10⁻⁵ Vahy s neautomatickou cinnosti Kalibrace – hmotnost Zatizeni etalonovym zavazim (dle OIML R111-1:2004) tridy M1 10 kg az 11 t CMC 3,2·10⁻⁵ KP-01","search_en":"Balances with non-automatic function Calibration – mass Loading using a class M1 reference weight (according to OIML R111-1:2004) 10 kg to 11 t CMC 3,2·10⁻⁵ KP-01","search_zh":"非自动衡器 校准 – 质量 用 M1 级标准砝码（按 OIML R111-1:2004）加载 10 kg 至 11 t CMC 3,2·10⁻⁵ KP-01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b85ff7ced7fa116bce9f0a9f","lab_id":"6ade8b4aff06824761708137","country":"CZ","accr_number":"2394","accr_body":"ČIA","row_label":"1","test_object":"Wagi nieautomatyczne","test_object_en":"Balances with non-automatic function","test_object_zh":"非自动衡器","test_object_cs":"Váhy s neautomatickou činností","methodology":"Wzorcowanie – masa","methodology_en":"Calibration – mass","methodology_zh":"校准 – 质量","methodology_cs":"Kalibrace – hmotnost","parameters":[{"name":"","range":"od 200 kg do 3 t","cmc":"6·10⁻⁴"},{"name":"","range":"od 3 t do 15 t","cmc":"9·10⁻⁴"},{"name":"","range":"od 15 t do 30 t","cmc":"8·10⁻⁴"}],"parameters_en":[{"name":"","range":"200 kg to 3 t","cmc":"6·10⁻⁴"},{"name":"","range":"3 t to 15 t","cmc":"9·10⁻⁴"},{"name":"","range":"15 t to 30 t","cmc":"8·10⁻⁴"}],"parameters_zh":[{"name":"","range":"200 kg 至 3 t","cmc":"6·10⁻⁴"},{"name":"","range":"3 t 至 15 t","cmc":"9·10⁻⁴"},{"name":"","range":"15 t 至 30 t","cmc":"8·10⁻⁴"}],"parameters_cs":[{"name":"","range":"200 kg až 3 t","cmc":"6·10⁻⁴"},{"name":"","range":"3 t až 15 t","cmc":"9·10⁻⁴"},{"name":"","range":"15 t až 30 t","cmc":"8·10⁻⁴"}],"technique":"Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy M1 z użyciem obciążenia zastępczego","technique_en":"Loading using a class M1 reference weight (according to OIML R111-1:2004) with the use of substitute load","technique_zh":"用 M1 级标准砝码（按 OIML R111-1:2004）加载并采用替代载荷","technique_cs":"Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy M1 s použitím substitučního zatížení","techniques":["Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy M1 z użyciem obciążenia zastępczego"],"techniques_en":["Loading using a class M1 reference weight (according to OIML R111-1:2004) with the use of substitute load"],"techniques_zh":["用 M1 级标准砝码（按 OIML R111-1:2004）加载并采用替代载荷"],"techniques_cs":["Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy M1 s použitím substitučního zatížení"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – masa\nZakres:\nod 200 kg do 3 t CMC 6·10⁻⁴\nod 3 t do 15 t CMC 9·10⁻⁴\nod 15 t do 30 t CMC 8·10⁻⁴\nObciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy M1 z użyciem obciążenia zastępczego","reference":"KP-01","norm_bases":["KP-01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: masa","regulatory_area_en":"CMC for the field of measured quantity: Mass","regulatory_area_zh":"被测量领域的CMC：质量","regulatory_area_cs":"CMC pro obor měřené veličiny: Hmotnost","flexible":false,"flexibility":null,"outside_premises":true,"note":"Odważnikom o indywidualnej wartości nominalnej leżącej między wartościami zdefiniowanymi przypisuje się niepewność bezpośrednio wyższą.","note_en":"Weights with an individual nominal value lying between the defined values are assigned the next higher uncertainty.","note_zh":"对于标称值介于规定值之间的单个砝码，取紧邻较高的不确定度。","note_cs":"U závaží s individuální jmenovitou hodnotou ležící mezi definovanými hodnotami je přiřazena nejistota bezprostředně vyšší.","search_text":"Wagi nieautomatyczne Wzorcowanie – masa Obciążenie odważnikiem wzorcowym (wg OIML R111-1:2004) klasy M1 z użyciem obciążenia zastępczego od 200 kg do 3 t CMC 6·10⁻⁴ od 3 t do 15 t CMC 9·10⁻⁴ od 15 t do 30 t CMC 8·10⁻⁴ Váhy s neautomatickou činností Kalibrace – hmotnost Zatížení etalonovým závažím (dle OIML R111-1:2004) třídy M1 s použitím substitučního zatížení 200 kg až 3 t CMC 6·10⁻⁴ 3 t až 15 t CMC 9·10⁻⁴ 15 t až 30 t CMC 8·10⁻⁴ KP-01 Wagi nieautomatyczne Wzorcowanie – masa Obciazenie odwaznikiem wzorcowym (wg OIML R111-1:2004) klasy M1 z uzyciem obciazenia zastepczego od 200 kg do 3 t CMC 6·10⁻⁴ od 3 t do 15 t CMC 9·10⁻⁴ od 15 t do 30 t CMC 8·10⁻⁴ Vahy s neautomatickou cinnosti Kalibrace – hmotnost Zatizeni etalonovym zavazim (dle OIML R111-1:2004) tridy M1 s pouzitim substitucniho zatizeni 200 kg az 3 t CMC 6·10⁻⁴ 3 t az 15 t CMC 9·10⁻⁴ 15 t az 30 t CMC 8·10⁻⁴ KP-01","search_en":"Balances with non-automatic function Calibration – mass Loading using a class M1 reference weight (according to OIML R111-1:2004) with the use of substitute load 200 kg to 3 t CMC 6·10⁻⁴ 3 t to 15 t CMC 9·10⁻⁴ 15 t to 30 t CMC 8·10⁻⁴ KP-01","search_zh":"非自动衡器 校准 – 质量 用 M1 级标准砝码（按 OIML R111-1:2004）加载并采用替代载荷 200 kg 至 3 t CMC 6·10⁻⁴ 3 t 至 15 t CMC 9·10⁻⁴ 15 t 至 30 t CMC 8·10⁻⁴ KP-01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cf394b0ce4e8a810fc6b3149","lab_id":"6ade8b4aff06824761708137","country":"CZ","accr_number":"2394","accr_body":"ČIA","row_label":"2","test_object":"Masa umowna odważników i ciał","test_object_en":"Conventional mass of weights and bodies","test_object_zh":"砝码和物体的约定质量","test_object_cs":"Konvenční hmotnost závaží a těles","methodology":"Wzorcowanie – masa","methodology_en":"Calibration – mass","methodology_zh":"校准 – 质量","methodology_cs":"Kalibrace – hmotnost","parameters":[{"name":"","range":"od 1 mg do 20 mg","cmc":"0,007 mg"},{"name":"","range":"od 20 mg do 500 mg","cmc":"0,016 mg"},{"name":"","range":"1 g","cmc":"0,020 mg"},{"name":"","range":"2 g","cmc":"0,021 mg"},{"name":"","range":"5 g","cmc":"0,025 mg"},{"name":"","range":"10 g","cmc":"0,05 mg"},{"name":"","range":"20 g","cmc":"0,05 mg"},{"name":"","range":"50 g","cmc":"0,06 mg"},{"name":"","range":"100 g","cmc":"0,2 mg"},{"name":"","range":"200 g","cmc":"0,2 mg"},{"name":"","range":"500 g","cmc":"0,4 mg"},{"name":"","range":"1 kg","cmc":"2 mg"},{"name":"","range":"2 kg","cmc":"2 mg"},{"name":"","range":"5 kg","cmc":"15 mg"},{"name":"","range":"10 kg","cmc":"20 mg"},{"name":"","range":"20 kg","cmc":"30 mg"},{"name":"","range":"50 kg","cmc":"50 mg"},{"name":"","range":"60 kg","cmc":"80 mg"}],"parameters_en":[{"name":"","range":"1 mg to 20 mg","cmc":"0,007 mg"},{"name":"","range":"20 mg to 500 mg","cmc":"0,016 mg"},{"name":"","range":"1 g","cmc":"0,020 mg"},{"name":"","range":"2 g","cmc":"0,021 mg"},{"name":"","range":"5 g","cmc":"0,025 mg"},{"name":"","range":"10 g","cmc":"0,05 mg"},{"name":"","range":"20 g","cmc":"0,05 mg"},{"name":"","range":"50 g","cmc":"0,06 mg"},{"name":"","range":"100 g","cmc":"0,2 mg"},{"name":"","range":"200 g","cmc":"0,2 mg"},{"name":"","range":"500 g","cmc":"0,4 mg"},{"name":"","range":"1 kg","cmc":"2 mg"},{"name":"","range":"2 kg","cmc":"2 mg"},{"name":"","range":"5 kg","cmc":"15 mg"},{"name":"","range":"10 kg","cmc":"20 mg"},{"name":"","range":"20 kg","cmc":"30 mg"},{"name":"","range":"50 kg","cmc":"50 mg"},{"name":"","range":"60 kg","cmc":"80 mg"}],"parameters_zh":[{"name":"","range":"1 mg 至 20 mg","cmc":"0,007 mg"},{"name":"","range":"20 mg 至 500 mg","cmc":"0,016 mg"},{"name":"","range":"1 g","cmc":"0,020 mg"},{"name":"","range":"2 g","cmc":"0,021 mg"},{"name":"","range":"5 g","cmc":"0,025 mg"},{"name":"","range":"10 g","cmc":"0,05 mg"},{"name":"","range":"20 g","cmc":"0,05 mg"},{"name":"","range":"50 g","cmc":"0,06 mg"},{"name":"","range":"100 g","cmc":"0,2 mg"},{"name":"","range":"200 g","cmc":"0,2 mg"},{"name":"","range":"500 g","cmc":"0,4 mg"},{"name":"","range":"1 kg","cmc":"2 mg"},{"name":"","range":"2 kg","cmc":"2 mg"},{"name":"","range":"5 kg","cmc":"15 mg"},{"name":"","range":"10 kg","cmc":"20 mg"},{"name":"","range":"20 kg","cmc":"30 mg"},{"name":"","range":"50 kg","cmc":"50 mg"},{"name":"","range":"60 kg","cmc":"80 mg"}],"parameters_cs":[{"name":"","range":"1 mg až 20 mg","cmc":"0,007 mg"},{"name":"","range":"20 mg až 500 mg","cmc":"0,016 mg"},{"name":"","range":"1 g","cmc":"0,020 mg"},{"name":"","range":"2 g","cmc":"0,021 mg"},{"name":"","range":"5 g","cmc":"0,025 mg"},{"name":"","range":"10 g","cmc":"0,05 mg"},{"name":"","range":"20 g","cmc":"0,05 mg"},{"name":"","range":"50 g","cmc":"0,06 mg"},{"name":"","range":"100 g","cmc":"0,2 mg"},{"name":"","range":"200 g","cmc":"0,2 mg"},{"name":"","range":"500 g","cmc":"0,4 mg"},{"name":"","range":"1 kg","cmc":"2 mg"},{"name":"","range":"2 kg","cmc":"2 mg"},{"name":"","range":"5 kg","cmc":"15 mg"},{"name":"","range":"10 kg","cmc":"20 mg"},{"name":"","range":"20 kg","cmc":"30 mg"},{"name":"","range":"50 kg","cmc":"50 mg"},{"name":"","range":"60 kg","cmc":"80 mg"}],"technique":"Porównanie z odważnikiem wzorcowym (wg OIML R111-1:2004) na wagach wzorcowych i komparatorach","technique_en":"Comparison with a reference weight (according to OIML R111-1:2004) using reference scales and comparators","technique_zh":"在标准天平和比较器上与标准砝码（按 OIML R111-1:2004）比较","technique_cs":"Porovnání s etalonovým závažím (dle OIML R111-1:2004) na etalonových vahách a komparátorech","techniques":["Porównanie z odważnikiem wzorcowym (wg OIML R111-1:2004) na wagach wzorcowych i komparatorach"],"techniques_en":["Comparison with a reference weight (according to OIML R111-1:2004) using reference scales and comparators"],"techniques_zh":["在标准天平和比较器上与标准砝码（按 OIML R111-1:2004）比较"],"techniques_cs":["Porovnání s etalonovým závažím (dle OIML R111-1:2004) na etalonových vahách a komparátorech"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – masa\nZakres:\nod 1 mg do 20 mg CMC 0,007 mg\nod 20 mg do 500 mg CMC 0,016 mg\n1 g CMC 0,020 mg\n2 g CMC 0,021 mg\n5 g CMC 0,025 mg\n10 g CMC 0,05 mg\n20 g CMC 0,05 mg\n50 g CMC 0,06 mg\n100 g CMC 0,2 mg\n200 g CMC 0,2 mg\n500 g CMC 0,4 mg\n1 kg CMC 2 mg\n2 kg CMC 2 mg\n5 kg CMC 15 mg\n10 kg CMC 20 mg\n20 kg CMC 30 mg\n50 kg CMC 50 mg\n60 kg CMC 80 mg\nPorównanie z odważnikiem wzorcowym (wg OIML R111-1:2004) na wagach wzorcowych i komparatorach","reference":"KP-06","norm_bases":["KP-06"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: masa","regulatory_area_en":"CMC for the field of measured quantity: Mass","regulatory_area_zh":"被测量领域的CMC：质量","regulatory_area_cs":"CMC pro obor měřené veličiny: Hmotnost","flexible":false,"flexibility":null,"outside_premises":false,"note":"Odważnikom o indywidualnej wartości nominalnej leżącej między wartościami zdefiniowanymi przypisuje się niepewność bezpośrednio wyższą.","note_en":"Weights with an individual nominal value lying between the defined values are assigned the next higher uncertainty.","note_zh":"对于标称值介于规定值之间的单个砝码，取紧邻较高的不确定度。","note_cs":"U závaží s individuální jmenovitou hodnotou ležící mezi definovanými hodnotami je přiřazena nejistota bezprostředně vyšší.","search_text":"Masa umowna odważników i ciał Wzorcowanie – masa Porównanie z odważnikiem wzorcowym (wg OIML R111-1:2004) na wagach wzorcowych i komparatorach od 1 mg do 20 mg CMC 0,007 mg od 20 mg do 500 mg CMC 0,016 mg 1 g CMC 0,020 mg 2 g CMC 0,021 mg 5 g CMC 0,025 mg 10 g CMC 0,05 mg 20 g CMC 0,05 mg 50 g CMC 0,06 mg 100 g CMC 0,2 mg 200 g CMC 0,2 mg 500 g CMC 0,4 mg 1 kg CMC 2 mg 2 kg CMC 2 mg 5 kg CMC 15 mg 10 kg CMC 20 mg 20 kg CMC 30 mg 50 kg CMC 50 mg 60 kg CMC 80 mg Konvenční hmotnost závaží a těles Kalibrace – hmotnost Porovnání s etalonovým závažím (dle OIML R111-1:2004) na etalonových vahách a komparátorech 1 mg až 20 mg CMC 0,007 mg 20 mg až 500 mg CMC 0,016 mg 1 g CMC 0,020 mg 2 g CMC 0,021 mg 5 g CMC 0,025 mg 10 g CMC 0,05 mg 20 g CMC 0,05 mg 50 g CMC 0,06 mg 100 g CMC 0,2 mg 200 g CMC 0,2 mg 500 g CMC 0,4 mg 1 kg CMC 2 mg 2 kg CMC 2 mg 5 kg CMC 15 mg 10 kg CMC 20 mg 20 kg CMC 30 mg 50 kg CMC 50 mg 60 kg CMC 80 mg KP-06 Masa umowna odwaznikow i cial Wzorcowanie – masa Porownanie z odwaznikiem wzorcowym (wg OIML R111-1:2004) na wagach wzorcowych i komparatorach od 1 mg do 20 mg CMC 0,007 mg od 20 mg do 500 mg CMC 0,016 mg 1 g CMC 0,020 mg 2 g CMC 0,021 mg 5 g CMC 0,025 mg 10 g CMC 0,05 mg 20 g CMC 0,05 mg 50 g CMC 0,06 mg 100 g CMC 0,2 mg 200 g CMC 0,2 mg 500 g CMC 0,4 mg 1 kg CMC 2 mg 2 kg CMC 2 mg 5 kg CMC 15 mg 10 kg CMC 20 mg 20 kg CMC 30 mg 50 kg CMC 50 mg 60 kg CMC 80 mg Konvencni hmotnost zavazi a teles Kalibrace – hmotnost Porovnani s etalonovym zavazim (dle OIML R111-1:2004) na etalonovych vahach a komparatorech 1 mg az 20 mg CMC 0,007 mg 20 mg az 500 mg CMC 0,016 mg 1 g CMC 0,020 mg 2 g CMC 0,021 mg 5 g CMC 0,025 mg 10 g CMC 0,05 mg 20 g CMC 0,05 mg 50 g CMC 0,06 mg 100 g CMC 0,2 mg 200 g CMC 0,2 mg 500 g CMC 0,4 mg 1 kg CMC 2 mg 2 kg CMC 2 mg 5 kg CMC 15 mg 10 kg CMC 20 mg 20 kg CMC 30 mg 50 kg CMC 50 mg 60 kg CMC 80 mg KP-06","search_en":"Conventional mass of weights and bodies Calibration – mass Comparison with a reference weight (according to OIML R111-1:2004) using reference scales and comparators 1 mg to 20 mg CMC 0,007 mg 20 mg to 500 mg CMC 0,016 mg 1 g CMC 0,020 mg 2 g CMC 0,021 mg 5 g CMC 0,025 mg 10 g CMC 0,05 mg 20 g CMC 0,05 mg 50 g CMC 0,06 mg 100 g CMC 0,2 mg 200 g CMC 0,2 mg 500 g CMC 0,4 mg 1 kg CMC 2 mg 2 kg CMC 2 mg 5 kg CMC 15 mg 10 kg CMC 20 mg 20 kg CMC 30 mg 50 kg CMC 50 mg 60 kg CMC 80 mg KP-06","search_zh":"砝码和物体的约定质量 校准 – 质量 在标准天平和比较器上与标准砝码（按 OIML R111-1:2004）比较 1 mg 至 20 mg CMC 0,007 mg 20 mg 至 500 mg CMC 0,016 mg 1 g CMC 0,020 mg 2 g CMC 0,021 mg 5 g CMC 0,025 mg 10 g CMC 0,05 mg 20 g CMC 0,05 mg 50 g CMC 0,06 mg 100 g CMC 0,2 mg 200 g CMC 0,2 mg 500 g CMC 0,4 mg 1 kg CMC 2 mg 2 kg CMC 2 mg 5 kg CMC 15 mg 10 kg CMC 20 mg 20 kg CMC 30 mg 50 kg CMC 50 mg 60 kg CMC 80 mg KP-06","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"de27ef697f76421f4470506a","lab_id":"6ade8b4aff06824761708137","country":"CZ","accr_number":"2394","accr_body":"ČIA","row_label":"1","test_object":"Prędkość obrotowa / obrotomierze","test_object_en":"Speed / rpm gauges","test_object_zh":"转速 / 转速表","test_object_cs":"Otáčky / otáčkoměry","methodology":"Wzorcowanie – prędkość obrotowa","methodology_en":"Calibration – rotational speed","methodology_zh":"校准 – 转速","methodology_cs":"Kalibrace – otáčky","parameters":[{"name":"","range":"od 10 min⁻¹ do 1000 min⁻¹","cmc":"2 min⁻¹"},{"name":"","range":"od 1000 min⁻¹ do 10000 min⁻¹","cmc":"3 min⁻¹"},{"name":"","range":"od 10000 min⁻¹ do 50000 min⁻¹","cmc":"0,012 % + 2 min⁻¹"}],"parameters_en":[{"name":"","range":"10 min⁻¹ to 1000 min⁻¹","cmc":"2 min⁻¹"},{"name":"","range":"1000 min⁻¹ to 10000 min⁻¹","cmc":"3 min⁻¹"},{"name":"","range":"10000 min⁻¹ to 50000 min⁻¹","cmc":"0,012 % + 2 min⁻¹"}],"parameters_zh":[{"name":"","range":"10 min⁻¹ 至 1000 min⁻¹","cmc":"2 min⁻¹"},{"name":"","range":"1000 min⁻¹ 至 10000 min⁻¹","cmc":"3 min⁻¹"},{"name":"","range":"10000 min⁻¹ 至 50000 min⁻¹","cmc":"0,012 % + 2 min⁻¹"}],"parameters_cs":[{"name":"","range":"10 min⁻¹ až 1000 min⁻¹","cmc":"2 min⁻¹"},{"name":"","range":"1000 min⁻¹ až 10000 min⁻¹","cmc":"3 min⁻¹"},{"name":"","range":"10000 min⁻¹ až 50000 min⁻¹","cmc":"0,012 % + 2 min⁻¹"}],"technique":"Porównanie z obrotomierzem wzorcowym","technique_en":"Comparison with a reference rpm gauge","technique_zh":"与标准转速表比较","technique_cs":"Porovnání s etalonovým otáčkoměrem","techniques":["Porównanie z obrotomierzem wzorcowym"],"techniques_en":["Comparison with a reference rpm gauge"],"techniques_zh":["与标准转速表比较"],"techniques_cs":["Porovnání s etalonovým otáčkoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – prędkość obrotowa\nZakres:\nod 10 min⁻¹ do 1000 min⁻¹ CMC 2 min⁻¹\nod 1000 min⁻¹ do 10000 min⁻¹ CMC 3 min⁻¹\nod 10000 min⁻¹ do 50000 min⁻¹ CMC 0,012 % + 2 min⁻¹\nPorównanie z obrotomierzem wzorcowym","reference":"KP-02","norm_bases":["KP-02"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: prędkość obrotowa","regulatory_area_en":"CMC for the field of measured quantity: Rotational speed","regulatory_area_zh":"被测量领域的CMC：转速","regulatory_area_cs":"CMC pro obor měřené veličiny: Otáčky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prędkość obrotowa / obrotomierze Wzorcowanie – prędkość obrotowa Porównanie z obrotomierzem wzorcowym od 10 min⁻¹ do 1000 min⁻¹ CMC 2 min⁻¹ od 1000 min⁻¹ do 10000 min⁻¹ CMC 3 min⁻¹ od 10000 min⁻¹ do 50000 min⁻¹ CMC 0,012 % + 2 min⁻¹ Otáčky / otáčkoměry Kalibrace – otáčky Porovnání s etalonovým otáčkoměrem 10 min⁻¹ až 1000 min⁻¹ CMC 2 min⁻¹ 1000 min⁻¹ až 10000 min⁻¹ CMC 3 min⁻¹ 10000 min⁻¹ až 50000 min⁻¹ CMC 0,012 % + 2 min⁻¹ KP-02 Predkosc obrotowa / obrotomierze Wzorcowanie – predkosc obrotowa Porownanie z obrotomierzem wzorcowym od 10 min⁻¹ do 1000 min⁻¹ CMC 2 min⁻¹ od 1000 min⁻¹ do 10000 min⁻¹ CMC 3 min⁻¹ od 10000 min⁻¹ do 50000 min⁻¹ CMC 0,012 % + 2 min⁻¹ Otacky / otackomery Kalibrace – otacky Porovnani s etalonovym otackomerem 10 min⁻¹ az 1000 min⁻¹ CMC 2 min⁻¹ 1000 min⁻¹ az 10000 min⁻¹ CMC 3 min⁻¹ 10000 min⁻¹ az 50000 min⁻¹ CMC 0,012 % + 2 min⁻¹ KP-02","search_en":"Speed / rpm gauges Calibration – rotational speed Comparison with a reference rpm gauge 10 min⁻¹ to 1000 min⁻¹ CMC 2 min⁻¹ 1000 min⁻¹ to 10000 min⁻¹ CMC 3 min⁻¹ 10000 min⁻¹ to 50000 min⁻¹ CMC 0,012 % + 2 min⁻¹ KP-02","search_zh":"转速 / 转速表 校准 – 转速 与标准转速表比较 10 min⁻¹ 至 1000 min⁻¹ CMC 2 min⁻¹ 1000 min⁻¹ 至 10000 min⁻¹ CMC 3 min⁻¹ 10000 min⁻¹ 至 50000 min⁻¹ CMC 0,012 % + 2 min⁻¹ KP-02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"83ea768eb5031187c4b7041d","lab_id":"6ade8b4aff06824761708137","country":"CZ","accr_number":"2394","accr_body":"ČIA","row_label":"1","test_object":"Termometry szklane","test_object_en":"Glass thermometers","test_object_zh":"玻璃温度计","test_object_cs":"Skleněné teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -40 °C do 20 °C","cmc":"0,15 °C"},{"name":"","range":"od 20 °C do 150 °C","cmc":"0,10 °C"},{"name":"","range":"od 150 °C do 180 °C","cmc":"0,12 °C"}],"parameters_en":[{"name":"","range":"-40 °C to 20 °C","cmc":"0,15 °C"},{"name":"","range":"20 °C to 150 °C","cmc":"0,10 °C"},{"name":"","range":"150 °C to 180 °C","cmc":"0,12 °C"}],"parameters_zh":[{"name":"","range":"-40 °C 至 20 °C","cmc":"0,15 °C"},{"name":"","range":"20 °C 至 150 °C","cmc":"0,10 °C"},{"name":"","range":"150 °C 至 180 °C","cmc":"0,12 °C"}],"parameters_cs":[{"name":"","range":"-40 °C až 20 °C","cmc":"0,15 °C"},{"name":"","range":"20 °C až 150 °C","cmc":"0,10 °C"},{"name":"","range":"150 °C až 180 °C","cmc":"0,12 °C"}],"technique":"Porównanie z termometrem wzorcowym w łaźni cieczowej","technique_en":"Comparison with a reference thermometer in a liquid bath","technique_zh":"在液体槽中与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem v kapalinové lázni","techniques":["Porównanie z termometrem wzorcowym w łaźni cieczowej"],"techniques_en":["Comparison with a reference thermometer in a liquid bath"],"techniques_zh":["在液体槽中与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -40 °C do 20 °C CMC 0,15 °C\nod 20 °C do 150 °C CMC 0,10 °C\nod 150 °C do 180 °C CMC 0,12 °C\nPorównanie z termometrem wzorcowym w łaźni cieczowej","reference":"KP-03 část C","norm_bases":["KP-03 část C"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry szklane Wzorcowanie – temperatura Porównanie z termometrem wzorcowym w łaźni cieczowej od -40 °C do 20 °C CMC 0,15 °C od 20 °C do 150 °C CMC 0,10 °C od 150 °C do 180 °C CMC 0,12 °C Skleněné teploměry Kalibrace – teplota Porovnání s etalonovým teploměrem v kapalinové lázni -40 °C až 20 °C CMC 0,15 °C 20 °C až 150 °C CMC 0,10 °C 150 °C až 180 °C CMC 0,12 °C KP-03 část C Termometry szklane Wzorcowanie – temperatura Porownanie z termometrem wzorcowym w lazni cieczowej od -40 °C do 20 °C CMC 0,15 °C od 20 °C do 150 °C CMC 0,10 °C od 150 °C do 180 °C CMC 0,12 °C Sklenene teplomery Kalibrace – teplota Porovnani s etalonovym teplomerem v kapalinove lazni -40 °C az 20 °C CMC 0,15 °C 20 °C az 150 °C CMC 0,10 °C 150 °C az 180 °C CMC 0,12 °C KP-03 cast C","search_en":"Glass thermometers Calibration – temperature Comparison with a reference thermometer in a liquid bath -40 °C to 20 °C CMC 0,15 °C 20 °C to 150 °C CMC 0,10 °C 150 °C to 180 °C CMC 0,12 °C KP-03 část C","search_zh":"玻璃温度计 校准 – 温度 在液体槽中与标准温度计比较 -40 °C 至 20 °C CMC 0,15 °C 20 °C 至 150 °C CMC 0,10 °C 150 °C 至 180 °C CMC 0,12 °C KP-03 část C","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a97697cff04c17f577e679b8","lab_id":"6ade8b4aff06824761708137","country":"CZ","accr_number":"2394","accr_body":"ČIA","row_label":"1","test_object":"Termometry wskazujące, tory pomiarowe temperatury","test_object_en":"Indicating thermometers, temperature measuring chains","test_object_zh":"指示式温度计、温度测量链","test_object_cs":"Indikační teploměry, měřící řetězce teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"-196 °C","cmc":"0,70 °C"}],"parameters_en":[{"name":"","range":"-196 °C","cmc":"0,70 °C"}],"parameters_zh":[{"name":"","range":"-196 °C","cmc":"0,70 °C"}],"parameters_cs":[{"name":"","range":"-196 °C","cmc":"0,70 °C"}],"technique":"Porównanie z termometrem wzorcowym w ciekłym azocie","technique_en":"Comparison with a reference thermometer in liquid nitrogen","technique_zh":"在液氮中与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem v tekutém dusíku","techniques":["Porównanie z termometrem wzorcowym w ciekłym azocie"],"techniques_en":["Comparison with a reference thermometer in liquid nitrogen"],"techniques_zh":["在液氮中与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem v tekutém dusíku"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\n-196 °C CMC 0,70 °C\nPorównanie z termometrem wzorcowym w ciekłym azocie","reference":"KP-03 část A","norm_bases":["KP-03 část A"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry wskazujące, tory pomiarowe temperatury Wzorcowanie – temperatura Porównanie z termometrem wzorcowym w ciekłym azocie -196 °C CMC 0,70 °C Indikační teploměry, měřící řetězce teploty Kalibrace – teplota Porovnání s etalonovým teploměrem v tekutém dusíku -196 °C CMC 0,70 °C KP-03 část A Termometry wskazujace, tory pomiarowe temperatury Wzorcowanie – temperatura Porownanie z termometrem wzorcowym w cieklym azocie -196 °C CMC 0,70 °C Indikacni teplomery, merici retezce teploty Kalibrace – teplota Porovnani s etalonovym teplomerem v tekutem dusiku -196 °C CMC 0,70 °C KP-03 cast A","search_en":"Indicating thermometers, temperature measuring chains Calibration – temperature Comparison with a reference thermometer in liquid nitrogen -196 °C CMC 0,70 °C KP-03 část A","search_zh":"指示式温度计、温度测量链 校准 – 温度 在液氮中与标准温度计比较 -196 °C CMC 0,70 °C KP-03 část A","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"473badb380aab19d67a1ef4b","lab_id":"6ade8b4aff06824761708137","country":"CZ","accr_number":"2394","accr_body":"ČIA","row_label":"1","test_object":"Termometry wskazujące, tory pomiarowe temperatury","test_object_en":"Indicating thermometers, temperature measuring chains","test_object_zh":"指示式温度计、温度测量链","test_object_cs":"Indikační teploměry, měřící řetězce teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -95 °C do -40 °C","cmc":"0,20 °C"},{"name":"","range":"od 180 °C do 230 °C","cmc":"0,25 °C"},{"name":"","range":"od 230 °C do 415 °C","cmc":"0,45 °C"},{"name":"","range":"od 415 °C do 600 °C","cmc":"1,5 °C"},{"name":"","range":"od 600 °C do 800 °C","cmc":"2,6 °C"},{"name":"","range":"od 800 °C do 1100 °C","cmc":"2,8 °C"}],"parameters_en":[{"name":"","range":"-95 °C to -40 °C","cmc":"0,20 °C"},{"name":"","range":"180 °C to 230 °C","cmc":"0,25 °C"},{"name":"","range":"230 °C to 415 °C","cmc":"0,45 °C"},{"name":"","range":"415 °C to 600 °C","cmc":"1,5 °C"},{"name":"","range":"600 °C to 800 °C","cmc":"2,6 °C"},{"name":"","range":"800 °C to 1100 °C","cmc":"2,8 °C"}],"parameters_zh":[{"name":"","range":"-95 °C 至 -40 °C","cmc":"0,20 °C"},{"name":"","range":"180 °C 至 230 °C","cmc":"0,25 °C"},{"name":"","range":"230 °C 至 415 °C","cmc":"0,45 °C"},{"name":"","range":"415 °C 至 600 °C","cmc":"1,5 °C"},{"name":"","range":"600 °C 至 800 °C","cmc":"2,6 °C"},{"name":"","range":"800 °C 至 1100 °C","cmc":"2,8 °C"}],"parameters_cs":[{"name":"","range":"-95 °C až -40 °C","cmc":"0,20 °C"},{"name":"","range":"180 °C až 230 °C","cmc":"0,25 °C"},{"name":"","range":"230 °C až 415 °C","cmc":"0,45 °C"},{"name":"","range":"415 °C až 600 °C","cmc":"1,5 °C"},{"name":"","range":"600 °C až 800 °C","cmc":"2,6 °C"},{"name":"","range":"800 °C až 1100 °C","cmc":"2,8 °C"}],"technique":"Porównanie z termometrem wzorcowym w piecyku blokowym","technique_en":"Comparison with a reference thermometer in a dry block","technique_zh":"在干井炉中与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem v blokové pícce","techniques":["Porównanie z termometrem wzorcowym w piecyku blokowym"],"techniques_en":["Comparison with a reference thermometer in a dry block"],"techniques_zh":["在干井炉中与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem v blokové pícce"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -95 °C do -40 °C CMC 0,20 °C\nod 180 °C do 230 °C CMC 0,25 °C\nod 230 °C do 415 °C CMC 0,45 °C\nod 415 °C do 600 °C CMC 1,5 °C\nod 600 °C do 800 °C CMC 2,6 °C\nod 800 °C do 1100 °C CMC 2,8 °C\nPorównanie z termometrem wzorcowym w piecyku blokowym","reference":"KP-03 část A","norm_bases":["KP-03 část A"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry wskazujące, tory pomiarowe temperatury Wzorcowanie – temperatura Porównanie z termometrem wzorcowym w piecyku blokowym od -95 °C do -40 °C CMC 0,20 °C od 180 °C do 230 °C CMC 0,25 °C od 230 °C do 415 °C CMC 0,45 °C od 415 °C do 600 °C CMC 1,5 °C od 600 °C do 800 °C CMC 2,6 °C od 800 °C do 1100 °C CMC 2,8 °C Indikační teploměry, měřící řetězce teploty Kalibrace – teplota Porovnání s etalonovým teploměrem v blokové pícce -95 °C až -40 °C CMC 0,20 °C 180 °C až 230 °C CMC 0,25 °C 230 °C až 415 °C CMC 0,45 °C 415 °C až 600 °C CMC 1,5 °C 600 °C až 800 °C CMC 2,6 °C 800 °C až 1100 °C CMC 2,8 °C KP-03 část A Termometry wskazujace, tory pomiarowe temperatury Wzorcowanie – temperatura Porownanie z termometrem wzorcowym w piecyku blokowym od -95 °C do -40 °C CMC 0,20 °C od 180 °C do 230 °C CMC 0,25 °C od 230 °C do 415 °C CMC 0,45 °C od 415 °C do 600 °C CMC 1,5 °C od 600 °C do 800 °C CMC 2,6 °C od 800 °C do 1100 °C CMC 2,8 °C Indikacni teplomery, merici retezce teploty Kalibrace – teplota Porovnani s etalonovym teplomerem v blokove picce -95 °C az -40 °C CMC 0,20 °C 180 °C az 230 °C CMC 0,25 °C 230 °C az 415 °C CMC 0,45 °C 415 °C az 600 °C CMC 1,5 °C 600 °C az 800 °C CMC 2,6 °C 800 °C az 1100 °C CMC 2,8 °C KP-03 cast A","search_en":"Indicating thermometers, temperature measuring chains Calibration – temperature Comparison with a reference thermometer in a dry block -95 °C to -40 °C CMC 0,20 °C 180 °C to 230 °C CMC 0,25 °C 230 °C to 415 °C CMC 0,45 °C 415 °C to 600 °C CMC 1,5 °C 600 °C to 800 °C CMC 2,6 °C 800 °C to 1100 °C CMC 2,8 °C KP-03 část A","search_zh":"指示式温度计、温度测量链 校准 – 温度 在干井炉中与标准温度计比较 -95 °C 至 -40 °C CMC 0,20 °C 180 °C 至 230 °C CMC 0,25 °C 230 °C 至 415 °C CMC 0,45 °C 415 °C 至 600 °C CMC 1,5 °C 600 °C 至 800 °C CMC 2,6 °C 800 °C 至 1100 °C CMC 2,8 °C KP-03 část A","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e37c173def771ff223c4a6d6","lab_id":"6ade8b4aff06824761708137","country":"CZ","accr_number":"2394","accr_body":"ČIA","row_label":"1","test_object":"Termometry wskazujące, tory pomiarowe temperatury","test_object_en":"Indicating thermometers, temperature measuring chains","test_object_zh":"指示式温度计、温度测量链","test_object_cs":"Indikační teploměry, měřící řetězce teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -40 °C do 20 °C","cmc":"0,15 °C"},{"name":"","range":"od 20 °C do 150 °C","cmc":"0,10 °C"},{"name":"","range":"od 150 °C do 180 °C","cmc":"0,12 °C"}],"parameters_en":[{"name":"","range":"-40 °C to 20 °C","cmc":"0,15 °C"},{"name":"","range":"20 °C to 150 °C","cmc":"0,10 °C"},{"name":"","range":"150 °C to 180 °C","cmc":"0,12 °C"}],"parameters_zh":[{"name":"","range":"-40 °C 至 20 °C","cmc":"0,15 °C"},{"name":"","range":"20 °C 至 150 °C","cmc":"0,10 °C"},{"name":"","range":"150 °C 至 180 °C","cmc":"0,12 °C"}],"parameters_cs":[{"name":"","range":"-40 °C až 20 °C","cmc":"0,15 °C"},{"name":"","range":"20 °C až 150 °C","cmc":"0,10 °C"},{"name":"","range":"150 °C až 180 °C","cmc":"0,12 °C"}],"technique":"Porównanie z termometrem wzorcowym w łaźni cieczowej","technique_en":"Comparison with a reference thermometer in a liquid bath","technique_zh":"在液体槽中与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem v kapalinové lázni","techniques":["Porównanie z termometrem wzorcowym w łaźni cieczowej"],"techniques_en":["Comparison with a reference thermometer in a liquid bath"],"techniques_zh":["在液体槽中与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -40 °C do 20 °C CMC 0,15 °C\nod 20 °C do 150 °C CMC 0,10 °C\nod 150 °C do 180 °C CMC 0,12 °C\nPorównanie z termometrem wzorcowym w łaźni cieczowej","reference":"KP-03 část A","norm_bases":["KP-03 část A"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry wskazujące, tory pomiarowe temperatury Wzorcowanie – temperatura Porównanie z termometrem wzorcowym w łaźni cieczowej od -40 °C do 20 °C CMC 0,15 °C od 20 °C do 150 °C CMC 0,10 °C od 150 °C do 180 °C CMC 0,12 °C Indikační teploměry, měřící řetězce teploty Kalibrace – teplota Porovnání s etalonovým teploměrem v kapalinové lázni -40 °C až 20 °C CMC 0,15 °C 20 °C až 150 °C CMC 0,10 °C 150 °C až 180 °C CMC 0,12 °C KP-03 část A Termometry wskazujace, tory pomiarowe temperatury Wzorcowanie – temperatura Porownanie z termometrem wzorcowym w lazni cieczowej od -40 °C do 20 °C CMC 0,15 °C od 20 °C do 150 °C CMC 0,10 °C od 150 °C do 180 °C CMC 0,12 °C Indikacni teplomery, merici retezce teploty Kalibrace – teplota Porovnani s etalonovym teplomerem v kapalinove lazni -40 °C az 20 °C CMC 0,15 °C 20 °C az 150 °C CMC 0,10 °C 150 °C az 180 °C CMC 0,12 °C KP-03 cast A","search_en":"Indicating thermometers, temperature measuring chains Calibration – temperature Comparison with a reference thermometer in a liquid bath -40 °C to 20 °C CMC 0,15 °C 20 °C to 150 °C CMC 0,10 °C 150 °C to 180 °C CMC 0,12 °C KP-03 část A","search_zh":"指示式温度计、温度测量链 校准 – 温度 在液体槽中与标准温度计比较 -40 °C 至 20 °C CMC 0,15 °C 20 °C 至 150 °C CMC 0,10 °C 150 °C 至 180 °C CMC 0,12 °C KP-03 část A","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"769eb466b607a9c20f3d7582","lab_id":"6ade8b4aff06824761708137","country":"CZ","accr_number":"2394","accr_body":"ČIA","row_label":"1","test_object":"Wzorcowanie urządzeń cieplnych z regulacją temperatury","test_object_en":"Calibration of thermal equipment with temperature control","test_object_zh":"带温度调节的热设备校准","test_object_cs":"Kalibrace teplotních zařízení s regulací teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -196 °C do -70 °C","cmc":"0,90 °C"},{"name":"","range":"od -70 °C do -40 °C","cmc":"0,60 °C"},{"name":"","range":"od -40 °C do 150 °C","cmc":"0,30 °C"},{"name":"","range":"od 150 °C do 230 °C","cmc":"0,45 °C"},{"name":"","range":"od 230 °C do 415 °C","cmc":"0,50 °C"},{"name":"","range":"od 415 °C do 600 °C","cmc":"1,6 °C"},{"name":"","range":"od 600 °C do 800 °C","cmc":"2,6 °C"},{"name":"","range":"od 800 °C do 1100 °C","cmc":"2,8 °C"}],"parameters_en":[{"name":"","range":"-196 °C to -70 °C","cmc":"0,90 °C"},{"name":"","range":"-70 °C to -40 °C","cmc":"0,60 °C"},{"name":"","range":"-40 °C to 150 °C","cmc":"0,30 °C"},{"name":"","range":"150 °C to 230 °C","cmc":"0,45 °C"},{"name":"","range":"230 °C to 415 °C","cmc":"0,50 °C"},{"name":"","range":"415 °C to 600 °C","cmc":"1,6 °C"},{"name":"","range":"600 °C to 800 °C","cmc":"2,6 °C"},{"name":"","range":"800 °C to 1100 °C","cmc":"2,8 °C"}],"parameters_zh":[{"name":"","range":"-196 °C 至 -70 °C","cmc":"0,90 °C"},{"name":"","range":"-70 °C 至 -40 °C","cmc":"0,60 °C"},{"name":"","range":"-40 °C 至 150 °C","cmc":"0,30 °C"},{"name":"","range":"150 °C 至 230 °C","cmc":"0,45 °C"},{"name":"","range":"230 °C 至 415 °C","cmc":"0,50 °C"},{"name":"","range":"415 °C 至 600 °C","cmc":"1,6 °C"},{"name":"","range":"600 °C 至 800 °C","cmc":"2,6 °C"},{"name":"","range":"800 °C 至 1100 °C","cmc":"2,8 °C"}],"parameters_cs":[{"name":"","range":"-196 °C až -70 °C","cmc":"0,90 °C"},{"name":"","range":"-70 °C až -40 °C","cmc":"0,60 °C"},{"name":"","range":"-40 °C až 150 °C","cmc":"0,30 °C"},{"name":"","range":"150 °C až 230 °C","cmc":"0,45 °C"},{"name":"","range":"230 °C až 415 °C","cmc":"0,50 °C"},{"name":"","range":"415 °C až 600 °C","cmc":"1,6 °C"},{"name":"","range":"600 °C až 800 °C","cmc":"2,6 °C"},{"name":"","range":"800 °C až 1100 °C","cmc":"2,8 °C"}],"technique":"Porównanie z termometrem wzorcowym","technique_en":"Comparison with a reference thermometer","technique_zh":"与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem","techniques":["Porównanie z termometrem wzorcowym"],"techniques_en":["Comparison with a reference thermometer"],"techniques_zh":["与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -196 °C do -70 °C CMC 0,90 °C\nod -70 °C do -40 °C CMC 0,60 °C\nod -40 °C do 150 °C CMC 0,30 °C\nod 150 °C do 230 °C CMC 0,45 °C\nod 230 °C do 415 °C CMC 0,50 °C\nod 415 °C do 600 °C CMC 1,6 °C\nod 600 °C do 800 °C CMC 2,6 °C\nod 800 °C do 1100 °C CMC 2,8 °C\nPorównanie z termometrem wzorcowym","reference":"KP-03 část B","norm_bases":["KP-03 část B"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wzorcowanie urządzeń cieplnych z regulacją temperatury Wzorcowanie – temperatura Porównanie z termometrem wzorcowym od -196 °C do -70 °C CMC 0,90 °C od -70 °C do -40 °C CMC 0,60 °C od -40 °C do 150 °C CMC 0,30 °C od 150 °C do 230 °C CMC 0,45 °C od 230 °C do 415 °C CMC 0,50 °C od 415 °C do 600 °C CMC 1,6 °C od 600 °C do 800 °C CMC 2,6 °C od 800 °C do 1100 °C CMC 2,8 °C Kalibrace teplotních zařízení s regulací teploty Kalibrace – teplota Porovnání s etalonovým teploměrem -196 °C až -70 °C CMC 0,90 °C -70 °C až -40 °C CMC 0,60 °C -40 °C až 150 °C CMC 0,30 °C 150 °C až 230 °C CMC 0,45 °C 230 °C až 415 °C CMC 0,50 °C 415 °C až 600 °C CMC 1,6 °C 600 °C až 800 °C CMC 2,6 °C 800 °C až 1100 °C CMC 2,8 °C KP-03 část B Wzorcowanie urzadzen cieplnych z regulacja temperatury Wzorcowanie – temperatura Porownanie z termometrem wzorcowym od -196 °C do -70 °C CMC 0,90 °C od -70 °C do -40 °C CMC 0,60 °C od -40 °C do 150 °C CMC 0,30 °C od 150 °C do 230 °C CMC 0,45 °C od 230 °C do 415 °C CMC 0,50 °C od 415 °C do 600 °C CMC 1,6 °C od 600 °C do 800 °C CMC 2,6 °C od 800 °C do 1100 °C CMC 2,8 °C Kalibrace teplotnich zarizeni s regulaci teploty Kalibrace – teplota Porovnani s etalonovym teplomerem -196 °C az -70 °C CMC 0,90 °C -70 °C az -40 °C CMC 0,60 °C -40 °C az 150 °C CMC 0,30 °C 150 °C az 230 °C CMC 0,45 °C 230 °C az 415 °C CMC 0,50 °C 415 °C az 600 °C CMC 1,6 °C 600 °C az 800 °C CMC 2,6 °C 800 °C az 1100 °C CMC 2,8 °C KP-03 cast B","search_en":"Calibration of thermal equipment with temperature control Calibration – temperature Comparison with a reference thermometer -196 °C to -70 °C CMC 0,90 °C -70 °C to -40 °C CMC 0,60 °C -40 °C to 150 °C CMC 0,30 °C 150 °C to 230 °C CMC 0,45 °C 230 °C to 415 °C CMC 0,50 °C 415 °C to 600 °C CMC 1,6 °C 600 °C to 800 °C CMC 2,6 °C 800 °C to 1100 °C CMC 2,8 °C KP-03 část B","search_zh":"带温度调节的热设备校准 校准 – 温度 与标准温度计比较 -196 °C 至 -70 °C CMC 0,90 °C -70 °C 至 -40 °C CMC 0,60 °C -40 °C 至 150 °C CMC 0,30 °C 150 °C 至 230 °C CMC 0,45 °C 230 °C 至 415 °C CMC 0,50 °C 415 °C 至 600 °C CMC 1,6 °C 600 °C 至 800 °C CMC 2,6 °C 800 °C 至 1100 °C CMC 2,8 °C KP-03 část B","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7029e99d6ebbb03fc1d36ff5","lab_id":"6ade8b4aff06824761708137","country":"CZ","accr_number":"2394","accr_body":"ČIA","row_label":"1","test_object":"Wzorcowanie bezdotykowych termometrów na podczerwień","test_object_en":"Calibration of infrared non-contact thermometers","test_object_zh":"红外非接触式温度计的校准","test_object_cs":"Kalibrace infračervených bezdotykových teploměrů","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -30 °C do 0 °C","cmc":"2,8 °C"},{"name":"","range":"od 0 °C do 20 °C","cmc":"1,6 °C"},{"name":"","range":"od 20 °C do 80 °C","cmc":"1,1 °C"},{"name":"","range":"od 80 °C do 200 °C","cmc":"1,5 °C"},{"name":"","range":"od 200 °C do 350 °C","cmc":"2,5 °C"},{"name":"","range":"od 350 °C do 500 °C","cmc":"3,7 °C"}],"parameters_en":[{"name":"","range":"-30 °C to 0 °C","cmc":"2,8 °C"},{"name":"","range":"0 °C to 20 °C","cmc":"1,6 °C"},{"name":"","range":"20 °C to 80 °C","cmc":"1,1 °C"},{"name":"","range":"80 °C to 200 °C","cmc":"1,5 °C"},{"name":"","range":"200 °C to 350 °C","cmc":"2,5 °C"},{"name":"","range":"350 °C to 500 °C","cmc":"3,7 °C"}],"parameters_zh":[{"name":"","range":"-30 °C 至 0 °C","cmc":"2,8 °C"},{"name":"","range":"0 °C 至 20 °C","cmc":"1,6 °C"},{"name":"","range":"20 °C 至 80 °C","cmc":"1,1 °C"},{"name":"","range":"80 °C 至 200 °C","cmc":"1,5 °C"},{"name":"","range":"200 °C 至 350 °C","cmc":"2,5 °C"},{"name":"","range":"350 °C 至 500 °C","cmc":"3,7 °C"}],"parameters_cs":[{"name":"","range":"-30 °C až 0 °C","cmc":"2,8 °C"},{"name":"","range":"0 °C až 20 °C","cmc":"1,6 °C"},{"name":"","range":"20 °C až 80 °C","cmc":"1,1 °C"},{"name":"","range":"80 °C až 200 °C","cmc":"1,5 °C"},{"name":"","range":"200 °C až 350 °C","cmc":"2,5 °C"},{"name":"","range":"350 °C až 500 °C","cmc":"3,7 °C"}],"technique":"Porównanie z termometrem wzorcowym (ciało czarne)","technique_en":"Comparison with a reference thermometer (black body)","technique_zh":"与标准温度计（黑体）比较","technique_cs":"Porovnání s etalonovým teploměrem (černé těleso)","techniques":["Porównanie z termometrem wzorcowym (ciało czarne)"],"techniques_en":["Comparison with a reference thermometer (black body)"],"techniques_zh":["与标准温度计（黑体）比较"],"techniques_cs":["Porovnání s etalonovým teploměrem (černé těleso)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -30 °C do 0 °C CMC 2,8 °C\nod 0 °C do 20 °C CMC 1,6 °C\nod 20 °C do 80 °C CMC 1,1 °C\nod 80 °C do 200 °C CMC 1,5 °C\nod 200 °C do 350 °C CMC 2,5 °C\nod 350 °C do 500 °C CMC 3,7 °C\nPorównanie z termometrem wzorcowym (ciało czarne)","reference":"KP-03-IR","norm_bases":["KP-03-IR"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wzorcowanie bezdotykowych termometrów na podczerwień Wzorcowanie – temperatura Porównanie z termometrem wzorcowym (ciało czarne) od -30 °C do 0 °C CMC 2,8 °C od 0 °C do 20 °C CMC 1,6 °C od 20 °C do 80 °C CMC 1,1 °C od 80 °C do 200 °C CMC 1,5 °C od 200 °C do 350 °C CMC 2,5 °C od 350 °C do 500 °C CMC 3,7 °C Kalibrace infračervených bezdotykových teploměrů Kalibrace – teplota Porovnání s etalonovým teploměrem (černé těleso) -30 °C až 0 °C CMC 2,8 °C 0 °C až 20 °C CMC 1,6 °C 20 °C až 80 °C CMC 1,1 °C 80 °C až 200 °C CMC 1,5 °C 200 °C až 350 °C CMC 2,5 °C 350 °C až 500 °C CMC 3,7 °C KP-03-IR Wzorcowanie bezdotykowych termometrow na podczerwien Wzorcowanie – temperatura Porownanie z termometrem wzorcowym (cialo czarne) od -30 °C do 0 °C CMC 2,8 °C od 0 °C do 20 °C CMC 1,6 °C od 20 °C do 80 °C CMC 1,1 °C od 80 °C do 200 °C CMC 1,5 °C od 200 °C do 350 °C CMC 2,5 °C od 350 °C do 500 °C CMC 3,7 °C Kalibrace infracervenych bezdotykovych teplomeru Kalibrace – teplota Porovnani s etalonovym teplomerem (cerne teleso) -30 °C az 0 °C CMC 2,8 °C 0 °C az 20 °C CMC 1,6 °C 20 °C az 80 °C CMC 1,1 °C 80 °C az 200 °C CMC 1,5 °C 200 °C az 350 °C CMC 2,5 °C 350 °C az 500 °C CMC 3,7 °C KP-03-IR","search_en":"Calibration of infrared non-contact thermometers Calibration – temperature Comparison with a reference thermometer (black body) -30 °C to 0 °C CMC 2,8 °C 0 °C to 20 °C CMC 1,6 °C 20 °C to 80 °C CMC 1,1 °C 80 °C to 200 °C CMC 1,5 °C 200 °C to 350 °C CMC 2,5 °C 350 °C to 500 °C CMC 3,7 °C KP-03-IR","search_zh":"红外非接触式温度计的校准 校准 – 温度 与标准温度计（黑体）比较 -30 °C 至 0 °C CMC 2,8 °C 0 °C 至 20 °C CMC 1,6 °C 20 °C 至 80 °C CMC 1,1 °C 80 °C 至 200 °C CMC 1,5 °C 200 °C 至 350 °C CMC 2,5 °C 350 °C 至 500 °C CMC 3,7 °C KP-03-IR","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"854c2b84baf331ca2da417ea","lab_id":"6ade8b4aff06824761708137","country":"CZ","accr_number":"2394","accr_body":"ČIA","row_label":"1","test_object":"Wilgotność względna / higrometry i tory pomiarowe wilgotności","test_object_en":"Relative humidity / hygrometers and humidity measuring chains","test_object_zh":"相对湿度 / 湿度计和湿度测量链","test_object_cs":"Relativní vlhkost / vlhkoměry a měřící řetězce vlhkosti","methodology":"Wzorcowanie – wilgotność powietrza","methodology_en":"Calibration – air humidity","methodology_zh":"校准 – 空气湿度","methodology_cs":"Kalibrace – vlhkost vzduchu","parameters":[{"name":"(13 do 33) °C","range":"od 10 % RH do 30 % RH","cmc":"1,2 % RH"},{"name":"(13 do 33) °C","range":"od 30 % RH do 60 % RH","cmc":"1,5 % RH"},{"name":"(13 do 33) °C","range":"od 60 % RH do 80 % RH","cmc":"1,7 % RH"},{"name":"(13 do 33) °C","range":"od 80 % RH do 95 % RH","cmc":"2,1 % RH"}],"parameters_en":[{"name":"(13 to 33) °C","range":"10 % RH to 30 % RH","cmc":"1,2 % RH"},{"name":"(13 to 33) °C","range":"30 % RH to 60 % RH","cmc":"1,5 % RH"},{"name":"(13 to 33) °C","range":"60 % RH to 80 % RH","cmc":"1,7 % RH"},{"name":"(13 to 33) °C","range":"80 % RH to 95 % RH","cmc":"2,1 % RH"}],"parameters_zh":[{"name":"(13 至 33) °C","range":"10 % RH 至 30 % RH","cmc":"1,2 % RH"},{"name":"(13 至 33) °C","range":"30 % RH 至 60 % RH","cmc":"1,5 % RH"},{"name":"(13 至 33) °C","range":"60 % RH 至 80 % RH","cmc":"1,7 % RH"},{"name":"(13 至 33) °C","range":"80 % RH 至 95 % RH","cmc":"2,1 % RH"}],"parameters_cs":[{"name":"(13 až 33) °C","range":"10 % RH až 30 % RH","cmc":"1,2 % RH"},{"name":"(13 až 33) °C","range":"30 % RH až 60 % RH","cmc":"1,5 % RH"},{"name":"(13 až 33) °C","range":"60 % RH až 80 % RH","cmc":"1,7 % RH"},{"name":"(13 až 33) °C","range":"80 % RH až 95 % RH","cmc":"2,1 % RH"}],"technique":"Porównanie z higrometrem wzorcowym","technique_en":"Comparison with a reference hygrometer","technique_zh":"与标准湿度计比较","technique_cs":"Porovnání s etalonovým vlhkoměrem","techniques":["Porównanie z higrometrem wzorcowym"],"techniques_en":["Comparison with a reference hygrometer"],"techniques_zh":["与标准湿度计比较"],"techniques_cs":["Porovnání s etalonovým vlhkoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wilgotność powietrza\nZakres:\n(13 do 33) °C od 10 % RH do 30 % RH CMC 1,2 % RH\n(13 do 33) °C od 30 % RH do 60 % RH CMC 1,5 % RH\n(13 do 33) °C od 60 % RH do 80 % RH CMC 1,7 % RH\n(13 do 33) °C od 80 % RH do 95 % RH CMC 2,1 % RH\nPorównanie z higrometrem wzorcowym","reference":"KP-04 část A","norm_bases":["KP-04 část A"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wilgotność powietrza","regulatory_area_en":"CMC for the field of measured quantity: Air humidity","regulatory_area_zh":"被测量领域的CMC：空气湿度","regulatory_area_cs":"CMC pro obor měřené veličiny: Vlhkost vzduchu","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wilgotność względna / higrometry i tory pomiarowe wilgotności Wzorcowanie – wilgotność powietrza Porównanie z higrometrem wzorcowym (13 do 33) °C od 10 % RH do 30 % RH CMC 1,2 % RH (13 do 33) °C od 30 % RH do 60 % RH CMC 1,5 % RH (13 do 33) °C od 60 % RH do 80 % RH CMC 1,7 % RH (13 do 33) °C od 80 % RH do 95 % RH CMC 2,1 % RH Relativní vlhkost / vlhkoměry a měřící řetězce vlhkosti Kalibrace – vlhkost vzduchu Porovnání s etalonovým vlhkoměrem (13 až 33) °C 10 % RH až 30 % RH CMC 1,2 % RH (13 až 33) °C 30 % RH až 60 % RH CMC 1,5 % RH (13 až 33) °C 60 % RH až 80 % RH CMC 1,7 % RH (13 až 33) °C 80 % RH až 95 % RH CMC 2,1 % RH KP-04 část A Wilgotnosc wzgledna / higrometry i tory pomiarowe wilgotnosci Wzorcowanie – wilgotnosc powietrza Porownanie z higrometrem wzorcowym (13 do 33) °C od 10 % RH do 30 % RH CMC 1,2 % RH (13 do 33) °C od 30 % RH do 60 % RH CMC 1,5 % RH (13 do 33) °C od 60 % RH do 80 % RH CMC 1,7 % RH (13 do 33) °C od 80 % RH do 95 % RH CMC 2,1 % RH Relativni vlhkost / vlhkomery a merici retezce vlhkosti Kalibrace – vlhkost vzduchu Porovnani s etalonovym vlhkomerem (13 az 33) °C 10 % RH az 30 % RH CMC 1,2 % RH (13 az 33) °C 30 % RH az 60 % RH CMC 1,5 % RH (13 az 33) °C 60 % RH az 80 % RH CMC 1,7 % RH (13 az 33) °C 80 % RH az 95 % RH CMC 2,1 % RH KP-04 cast A","search_en":"Relative humidity / hygrometers and humidity measuring chains Calibration – air humidity Comparison with a reference hygrometer (13 to 33) °C 10 % RH to 30 % RH CMC 1,2 % RH (13 to 33) °C 30 % RH to 60 % RH CMC 1,5 % RH (13 to 33) °C 60 % RH to 80 % RH CMC 1,7 % RH (13 to 33) °C 80 % RH to 95 % RH CMC 2,1 % RH KP-04 část A","search_zh":"相对湿度 / 湿度计和湿度测量链 校准 – 空气湿度 与标准湿度计比较 (13 至 33) °C 10 % RH 至 30 % RH CMC 1,2 % RH (13 至 33) °C 30 % RH 至 60 % RH CMC 1,5 % RH (13 至 33) °C 60 % RH 至 80 % RH CMC 1,7 % RH (13 至 33) °C 80 % RH 至 95 % RH CMC 2,1 % RH KP-04 část A","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"369be45f25cfb68d5b5437b7","lab_id":"6ade8b4aff06824761708137","country":"CZ","accr_number":"2394","accr_body":"ČIA","row_label":"1","test_object":"Wilgotność względna / tory pomiarowe i charakterystyka komór klimatycznych","test_object_en":"Relative humidity / measuring chains and characterisation of climatic chambers","test_object_zh":"相对湿度 / 测量链及气候箱特性测定","test_object_cs":"Relativní vlhkost / měřící řetězce a charakterizace klimatických komor","methodology":"Wzorcowanie – wilgotność powietrza","methodology_en":"Calibration – air humidity","methodology_zh":"校准 – 空气湿度","methodology_cs":"Kalibrace – vlhkost vzduchu","parameters":[{"name":"(13 do 33) °C","range":"od 10 % RH do 30 % RH","cmc":"1,5 % RH"},{"name":"(13 do 33) °C","range":"od 30 % RH do 60 % RH","cmc":"1,7 % RH"},{"name":"(13 do 33) °C","range":"od 60 % RH do 80 % RH","cmc":"1,8 % RH"},{"name":"(13 do 33) °C","range":"od 80 % RH do 95 % RH","cmc":"2,1 % RH"}],"parameters_en":[{"name":"(13 to 33) °C","range":"10 % RH to 30 % RH","cmc":"1,5 % RH"},{"name":"(13 to 33) °C","range":"30 % RH to 60 % RH","cmc":"1,7 % RH"},{"name":"(13 to 33) °C","range":"60 % RH to 80 % RH","cmc":"1,8 % RH"},{"name":"(13 to 33) °C","range":"80 % RH to 95 % RH","cmc":"2,1 % RH"}],"parameters_zh":[{"name":"(13 至 33) °C","range":"10 % RH 至 30 % RH","cmc":"1,5 % RH"},{"name":"(13 至 33) °C","range":"30 % RH 至 60 % RH","cmc":"1,7 % RH"},{"name":"(13 至 33) °C","range":"60 % RH 至 80 % RH","cmc":"1,8 % RH"},{"name":"(13 至 33) °C","range":"80 % RH 至 95 % RH","cmc":"2,1 % RH"}],"parameters_cs":[{"name":"(13 až 33) °C","range":"10 % RH až 30 % RH","cmc":"1,5 % RH"},{"name":"(13 až 33) °C","range":"30 % RH až 60 % RH","cmc":"1,7 % RH"},{"name":"(13 až 33) °C","range":"60 % RH až 80 % RH","cmc":"1,8 % RH"},{"name":"(13 až 33) °C","range":"80 % RH až 95 % RH","cmc":"2,1 % RH"}],"technique":"Porównanie z higrometrem wzorcowym","technique_en":"Comparison with a reference hygrometer","technique_zh":"与标准湿度计比较","technique_cs":"Porovnání s etalonovým vlhkoměrem","techniques":["Porównanie z higrometrem wzorcowym"],"techniques_en":["Comparison with a reference hygrometer"],"techniques_zh":["与标准湿度计比较"],"techniques_cs":["Porovnání s etalonovým vlhkoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wilgotność powietrza\nZakres:\n(13 do 33) °C od 10 % RH do 30 % RH CMC 1,5 % RH\n(13 do 33) °C od 30 % RH do 60 % RH CMC 1,7 % RH\n(13 do 33) °C od 60 % RH do 80 % RH CMC 1,8 % RH\n(13 do 33) °C od 80 % RH do 95 % RH CMC 2,1 % RH\nPorównanie z higrometrem wzorcowym","reference":"KP-04 část B","norm_bases":["KP-04 část B"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wilgotność powietrza","regulatory_area_en":"CMC for the field of measured quantity: Air humidity","regulatory_area_zh":"被测量领域的CMC：空气湿度","regulatory_area_cs":"CMC pro obor měřené veličiny: Vlhkost vzduchu","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wilgotność względna / tory pomiarowe i charakterystyka komór klimatycznych Wzorcowanie – wilgotność powietrza Porównanie z higrometrem wzorcowym (13 do 33) °C od 10 % RH do 30 % RH CMC 1,5 % RH (13 do 33) °C od 30 % RH do 60 % RH CMC 1,7 % RH (13 do 33) °C od 60 % RH do 80 % RH CMC 1,8 % RH (13 do 33) °C od 80 % RH do 95 % RH CMC 2,1 % RH Relativní vlhkost / měřící řetězce a charakterizace klimatických komor Kalibrace – vlhkost vzduchu Porovnání s etalonovým vlhkoměrem (13 až 33) °C 10 % RH až 30 % RH CMC 1,5 % RH (13 až 33) °C 30 % RH až 60 % RH CMC 1,7 % RH (13 až 33) °C 60 % RH až 80 % RH CMC 1,8 % RH (13 až 33) °C 80 % RH až 95 % RH CMC 2,1 % RH KP-04 část B Wilgotnosc wzgledna / tory pomiarowe i charakterystyka komor klimatycznych Wzorcowanie – wilgotnosc powietrza Porownanie z higrometrem wzorcowym (13 do 33) °C od 10 % RH do 30 % RH CMC 1,5 % RH (13 do 33) °C od 30 % RH do 60 % RH CMC 1,7 % RH (13 do 33) °C od 60 % RH do 80 % RH CMC 1,8 % RH (13 do 33) °C od 80 % RH do 95 % RH CMC 2,1 % RH Relativni vlhkost / merici retezce a charakterizace klimatickych komor Kalibrace – vlhkost vzduchu Porovnani s etalonovym vlhkomerem (13 az 33) °C 10 % RH az 30 % RH CMC 1,5 % RH (13 az 33) °C 30 % RH az 60 % RH CMC 1,7 % RH (13 az 33) °C 60 % RH az 80 % RH CMC 1,8 % RH (13 az 33) °C 80 % RH az 95 % RH CMC 2,1 % RH KP-04 cast B","search_en":"Relative humidity / measuring chains and characterisation of climatic chambers Calibration – air humidity Comparison with a reference hygrometer (13 to 33) °C 10 % RH to 30 % RH CMC 1,5 % RH (13 to 33) °C 30 % RH to 60 % RH CMC 1,7 % RH (13 to 33) °C 60 % RH to 80 % RH CMC 1,8 % RH (13 to 33) °C 80 % RH to 95 % RH CMC 2,1 % RH KP-04 část B","search_zh":"相对湿度 / 测量链及气候箱特性测定 校准 – 空气湿度 与标准湿度计比较 (13 至 33) °C 10 % RH 至 30 % RH CMC 1,5 % RH (13 至 33) °C 30 % RH 至 60 % RH CMC 1,7 % RH (13 至 33) °C 60 % RH 至 80 % RH CMC 1,8 % RH (13 至 33) °C 80 % RH 至 95 % RH CMC 2,1 % RH KP-04 část B","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"70140972305318552ec7800c","lab_id":"6ade8b4aff06824761708137","country":"CZ","accr_number":"2394","accr_body":"ČIA","row_label":"1","test_object":"Przedział czasu / stopery, timery, przyrządy do pomiaru czasu","test_object_en":"Time interval / stopwatches, timers and chronometers","test_object_zh":"时间间隔 / 秒表、定时器、计时器","test_object_cs":"Časový interval / stopky, časovače, měřiče času","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"","range":"od 1 s do 86400 s","cmc":"0,15 s"}],"parameters_en":[{"name":"","range":"1 s to 86400 s","cmc":"0,15 s"}],"parameters_zh":[{"name":"","range":"1 s 至 86400 s","cmc":"0,15 s"}],"parameters_cs":[{"name":"","range":"1 s až 86400 s","cmc":"0,15 s"}],"technique":"Porównanie ze stoperami wzorcowymi, uruchamianie ręczne","technique_en":"Comparison with reference stopwatches, manual activation","technique_zh":"与标准秒表比较，手动启动","technique_cs":"Porovnání s etalonovými stopkami, ruční spouštění","techniques":["Porównanie ze stoperami wzorcowymi, uruchamianie ręczne"],"techniques_en":["Comparison with reference stopwatches, manual activation"],"techniques_zh":["与标准秒表比较，手动启动"],"techniques_cs":["Porovnání s etalonovými stopkami, ruční spouštění"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\nod 1 s do 86400 s CMC 0,15 s\nPorównanie ze stoperami wzorcowymi, uruchamianie ręczne","reference":"KP-07","norm_bases":["KP-07"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przedział czasu / stopery, timery, przyrządy do pomiaru czasu Wzorcowanie – wielkości czasu i częstotliwości Porównanie ze stoperami wzorcowymi, uruchamianie ręczne od 1 s do 86400 s CMC 0,15 s Časový interval / stopky, časovače, měřiče času Kalibrace – veličiny času a frekvence Porovnání s etalonovými stopkami, ruční spouštění 1 s až 86400 s CMC 0,15 s KP-07 Przedzial czasu / stopery, timery, przyrzady do pomiaru czasu Wzorcowanie – wielkosci czasu i czestotliwosci Porownanie ze stoperami wzorcowymi, uruchamianie reczne od 1 s do 86400 s CMC 0,15 s Casovy interval / stopky, casovace, merice casu Kalibrace – veliciny casu a frekvence Porovnani s etalonovymi stopkami, rucni spousteni 1 s az 86400 s CMC 0,15 s KP-07","search_en":"Time interval / stopwatches, timers and chronometers Calibration – time and frequency quantities Comparison with reference stopwatches, manual activation 1 s to 86400 s CMC 0,15 s KP-07","search_zh":"时间间隔 / 秒表、定时器、计时器 校准 – 时间和频率量 与标准秒表比较，手动启动 1 s 至 86400 s CMC 0,15 s KP-07","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}